Loading...
HomeMy WebLinkAboutSUBMITTED PAPERS/ - - '01' - DATE: FEES DUE: " RECEIPT #: Permit #: • _ Planning & Development Services Department Building & Code Regulation Division 0 2300 Virginia Avenue S C Ft. Pierce, FL 34982-5652 A NEED Tel. 772-462-1553 APPLICATION .FOR ROOF PERMIT St. Lucie Count'/ SEE REVERSE SIDE FOR INSTRUCTIONS y 1. Location/Site Address: 8833 Lonesome Pine Trail, Fort Pierce, Florida 34945 2. Parcel ID Number: 2323-701-0050-000-5 Office Use i Only 3. Description of Project or Work Activity: Tear -off main house 4. Total Roof Area (square feet): ah 5. Roof Pitch: 5/12 6. Type of Roof: [ .x] Fiberglass Shingle [ ] Concrete Roof Tile [ ] Wood Shake / Shingle [ ] Tar & Gravel [ ] Modified Bitumen [ ] Other [ x] Product Approval required for all types of Roofing Material (2 Sets) ] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product Approval attached Roof Mitigation per F.S. 553.844 will be required. 7. Owner Information 8. Contractor Information Name: William & Wanda Gahn Address: 8833 Lonesome Pine Trail City: Fort Pierce State: A Zip: 34945 Phone: pa�3 9. Value of Construction: $ 2400 FL Reg/Cert #: CCC1326015 County Cert #: a Business Name: WWW Enterprises & Son. Inc. Cell Phone: 772-201-2039 "Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval. CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all of th orluation contained in pplication is correct and that all work will be done in compliapee, all app ' able 1 re g construction and zoning. PRINT U LIFIE OWNERS NAME SIG ATURE OF QUALI OWNER STATE OF FLORIDA, COUNTY OF ACKNOWLEDGED BEFORE ME TIIIS DAY OF 20�BY IS PERSONALLY KNOWN i_ TQ Mliy PR HAS OR PRINT I AME OF COMMISSION NUMBER -AS ID i rTION ANGELA" HUFF - f�1 - *: MYCOMft2PSgI0N# EE083530 (v(` •....;4�' EXPIpES: April 12, 2015 bonded Thru Notary public Underwriter; NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Revised 4/26/2010 3. Description of Project or Work Activity: Tear -off main house 4. Total Roof Area (square feet): ah 5. Roof Pitch: 5/12 6. Type of Roof: [ .x] Fiberglass Shingle [ ] Concrete Roof Tile [ ] Wood Shake / Shingle [ ] Tar & Gravel [ ] Modified Bitumen [ ] Other [ x] Product Approval required for all types of Roofing Material (2 Sets) ] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product Approval attached Roof Mitigation per F.S. 553.844 will be required. 7. Owner Information 8. Contractor Information Name: William & Wanda Gahn Address: 8833 Lonesome Pine Trail City: Fort Pierce State: A Zip: 34945 Phone: pa�3 9. Value of Construction: $ 2400 FL Reg/Cert #: CCC1326015 County Cert #: a Business Name: WWW Enterprises & Son. Inc. Cell Phone: 772-201-2039 "Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval. CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all of th orluation contained in pplication is correct and that all work will be done in compliapee, all app ' able 1 re g construction and zoning. PRINT U LIFIE OWNERS NAME SIG ATURE OF QUALI OWNER STATE OF FLORIDA, COUNTY OF ACKNOWLEDGED BEFORE ME TIIIS DAY OF 20�BY IS PERSONALLY KNOWN i_ TQ Mliy PR HAS OR PRINT I AME OF COMMISSION NUMBER -AS ID i rTION ANGELA" HUFF - f�1 - *: MYCOMft2PSgI0N# EE083530 (v(` •....;4�' EXPIpES: April 12, 2015 bonded Thru Notary public Underwriter; NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Revised 4/26/2010 Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 772-462-2165 or 772-462-2172 Fax: 772-462-6443 ROOF INSPECTION AFFIDAVIT Re: Permit # --0� I, Wanda Gahn , licensed as a(n)Contractor*/Engineer/Architect (Please print name & circle license type) *FS468 Building Inspector *General, Building, Residential or Roofing Contractor or any individual certified under 468 F.S. to make such an inspection. On or about 8/7/2013 , 1 did personally inspect the roof deck nailing (Date) work at: 8833 Lonesome Pine Trail, Fort Pierce, Florida 34945 (Job site address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S.) Signature and Seal STATE OF FLORIDA COUNTY OF orn to and subscribed beforpme this 20� 'L,�Da" (2ZIDN. Who i rsonally known to r who has produced as identi is ' . Sw by CCC1326015 License # Notary Public, State of/FiWida Signature of Notary: Commission Number: ANGELq MHUFF En 01/19/2011 ? : :*_ MYCOA4' ' pe: PkplSSION # EE 083530 Pf O"`ondcd Th INO April 12 2015 N Notary public Underwriters Florida Building Code Online Page 1 of 2 Fla:!da Depar" t Busines Professi �I Regulation BCIS Home Log In User Registration i Hot Topic ( Submit Surcharge ( Stats & Facts ( Publications ( FBC Staff BCIS Site Map Links Search j Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL5259-R18 �; ` Application Type Revision Code Version 2010 ,% ;Z Application Status Approved �. Commentss srjc Archived �C 41 Product Manufacturer POLYGLASS USA Address/Phone/Email 150 Lyon Drive Fernley, NV 89408 (570)384-1230 Ext242 jakins@polyglass.com Authorized Signature James Akins jakins@polyglass.com Technical Representative Steve Wadding Address/Phone/Email 150 Lyon Drive Fernley, NV 98408 (602)363-7139 stevew@polyglass.com Quality Assurance Representative James Akins Address/Phone/Email 555 Oakridge Road Humboldt Industrial Pkwy Hazleton, PA 18201 (800)894-4563 jakins@polyglass.com Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who Robert Nieminen developed the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 08/08/2015 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL5259 R18 COI Trinity ERD CI - Nieminen - 2013.adf Referenced Standard and Year (of Standard) Standard Year ASTM D1970 2001 ASTM D226 2006 ASTM D6164 2005 http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvbSgAaZp3Crk2... V12013 Florida Building Code Online Page 2 of 2 ASTM D6222 2002 ASTM G154 2005 ASTM G155 2005 FM 4474 2004 FRSA/TRI07320 2005 TAS 103 1995 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/26/2013 Date Validated 04/26/2013 Date Pending FBC Approval 05/03/2013 Date Approved 06/11/2013 Summary of Products FL # Model, Number or Description Name 5259.1 Polyglass Roof Roofing underlayments j Underlayments Limits of Use Installation Instructions Approved for use in HVHZ: No FL5259 R18 II er042613FINAL POLYGLASS UNDERLAYMENTS FL5259- Approved for use outside R18.Ddf j HVHZ: Yes Verified By: Robert Nieminen PE-59166 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-622.5 Evaluation Reports Other: 1.) The design pressure in this FL5259 R18 AE er042613FINAL POLYGLASS UNDERLAYMENTS FL5259- R18.Ddf application relates to one particular underlayment system for use under Created by Independent Third Party: Yes foam -on tile systems. Refer to ER Section 5.5.2 for other systems and maximum design pressures. 2.) Refer Ito ER Section 5 for other limits of use. Back Next Contact Us :: 1940 North Monroe Street. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. 'Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F,S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click hem. Product Approval Accepts: a�FscE �CU.ritV�t�. rtx[t� u-�• I � ^'`'art . http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvbSq—aZp3 Crk2... .8/7/2013 '�� TRKFIA IINI EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 ER® OXFORD, CT 06478 PHONE: (203) 262-9245 FAX:(203) 262-9243 EVALUATION REPORT Polyglass USA, Inc. 150 Lyon Drive Fernley, NV 98408 Evaluation Report P12060.02.09-R13 FL5259-R18 Date of Issuance: 02/24/2009 Revision 13: 04/26/2013 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2010 Florida Building Code sections noted herein. DESCRIPTION: Polyglass Roof Underlayments LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 10. Prepared by: Robert 3.11011. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 04/26/2013 This does not serve as an electronically signed document. Signed, sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. TrinitylERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest In any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. \I TRIN1lY i Etta ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.3, 1507.3.3, 1507.5.3, Physical Properties ASTM D226 2006 1507.7.3, 1507.8.3, 1507.9.3 1507.2.4, 1507.2.9.2, 1507.3.3, Physical Properties ASTM D1970 2001 1507.5.3 1507.11.2 Physical Properties ASTM D6164 2005 1507.11.2 Physical Properties ASTM D6222 2002 1504.6 Accelerated Weathering ASTM G154 2005 1504.6 Accelerated Weathering ASTM G155 2005 1504.3.1 Wind Uplift FM 4474 2004 1507.3.3 Installation Practice FRSA/TRI 07320 2005 1523.6.5.2.1 Physical Properties TAS 103 1995 3. REFERENCES: Entit Examination Reference Date FM Approvals (TST 1867) Wind Uplift 3004091 01/12/2000 PRI (TST 5878) Physical Properties PRIO1111 04/08/2002 PRI (TST 5878) Physical Properties PUSA-005-02-01 01/31/2002 PRI (TST 5878) Physical Properties PUSA-013-02-01 12/23/2002 PRI (TST 5878) Physical Properties PUSA-013-02-02 12/23/2002 PRI (TST 5878) Physical Properties PUSA-013-02-03 12/23/2002 PRI (TST 5878) Physical Properties PUSA-018-02-01 07/14/2003 PRI (TST 5878) Physical Properties PUSA-028-02-01 07/13/2005 PRI (TST 5878) Physical Properties PUSA-033-02-01 01/12/2006 PRI (TST 5878) Physical Properties PUSA-035-02-01 09/29/2006 PRI (TST 5878) Physical Properties PUSA-055-02-02 12/10/2007 PRI (TST 5878) Physical Properties PUSA-061-02-02 01/28/2008 PRI (TST 5878) Physical Properties PUSA-076-02-01 02/22/2008 PRI (TST 5878) Physical Properties PUSA-083-02-01 04/14/2008 PRI (TST 5878) Physical Properties PUSA-088-02-01 07/29/2009 MTI (TST 2508) Physical Properties JX20H7A 04/01/2008 MTI (TST 2508) Physical Properties RX14E8A 01/29/2009 ERD (TST 6049) Physical Properties 11752.09.99-1 02/08/2000 ERD (TST 6049) Wind Uplift 11776.06.02 01/16/2003 ERD (TST 6049) Physical Properties 02200.07.03 07/14/2003 ERD (TST 6049) Wind Uplift P1740.01.07 01/04/2007 ERD (TST 6049) Physical Properties P5110.04.07-1 04/11/2007 ERD (TST 6049) Wind Uplift P9260.03.08 03/21/2008 ERD (TST 6049) Physical Properties P13450.08.09 08/13/2009 ERD (TST 6049) Wind Uplift P30540.11.09-111 11/30/2009 ERD (TST 6049) Physical Properties P11030.11.09-1 11/30/2009 ERD (TST 6049) Wind Uplift P11030.11.09-2 11/30/2009 ERD (TST 6049) Physical Properties P11030.11.09-3 11/30/2009 ERD (TST 6049) Physical Properties P33360.06.10 06/25/2010 ERD (TST 6049) Physical Properties P33370.03.11 03/02/2011 ERD (TST 6049) Physical Properties P33370.04.11 04/26/2011 ERD (TST 6049) Physical Properties P37300.10.11 10/19/2011 ERD (TST 6049) Physical Properties P40390.08.12-1 08/06/2012 ERD (TST 6049) Physical Properties P40390.08.12-2 08/07/2012 ERD (TST 6049) Physical Properties C41420.09.12-3 09/11/2012 ERD (TST 6049) Physical Properties P45370.04.13 04/26/2013 ICC-ES (EVL 2396) IBC Compliance ESR-1697 09/01/2012 Miami -Dade (CER 1592) HVHZ Compliance NOA 12-0713.02 02/14/2013 Polyglass USA Manufacturing Affidavit Products Current 02/18/2009 Polyglass USA P/L Affidavit Mule -Hide Cross Ltg 03/01/2008 Exterior Research and Design, LLC. Evaluation Report 11212060.02.09-11113 Certificate of Authorization #9503 FLS2S9-R18 Revision 13: 04/26/2013 Page 2 of 10 Entity Polyglass USA UL, LLC. (QUA9625) 4. PRODUCT DESCRIPTION: r�o ,J TRINITY I ERD Examination Reference Date Materials Affidavit Polystick SA Compound 08/18/2011 Quality Control Service Confirmation Exp. 08/08/2015 4.1 Mechanically Fastened Underlayments: 4.1.1 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet. 4.1.2 Elastobase P is a polyester -reinforced, SBS modified bitumen base sheet. ,�4�2�rSe1f=A"dheri giUnderlauments: 4.2.1 Polystick MTS is a nominal 60=r11 thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced with polyolefinic film surface; meets ASTM D1970 and TAS 103. 4.2.2 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an aggregate surface; meets ASTM D1970. 4.2.3 Polystick TU is a nominal 100-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a granular surface; meets ASTM D1970 and TAS 103. 4.2.4 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a polyester fabric surface; meets ASTM D1970 and TAS 103. 4.2.5 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass- fiber/polyester reinforced, with a granular surface; meets ASTM D1970 and TAS 103. 4.2.6 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 170 g/m2 polyester fabric surface; meets TAS 103. 4.2.7 Polyflex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) are a polyester reinforced, APP modified bitumen cap sheets. 4.2.8 Dual PrOTM is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface. 4.2.9 Tile PrOT" is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface. 4.3 Mechanically Fastened and/or Bonded Underlayments: 4.3.1 Elastoflex S6 G and Elastoflex S6 G FR are polyester reinforced, SBS modified bitumen cap sheets. 4.3.2 Polyflex G and Polyflex G FR are polyester reinforced, APP modified bitumen cap sheets. S. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ. 5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.3 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the AH] for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.4 Allowable roof covers applied atop the underlayments are as follows: Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1113 Certitieate of Authorization #9503 FL5259-RlS Revision 13: 04/26/2013 Page 3 of 10 F�o \I TRINITY I ERD Table 1: Roof Cover Options Underlayment Asphalt Nail -On Tile Foam -On Metal Wood Shakes & Slate Shingles Tile Shingles Elastobase Yes Yes No Yes Yes Yes Elastobase P Yes Yes No Yes Yes Yes Polystick MTS Yes Yes No Yes Yes Yes Polystick IR-Xe Yes No No No Yes Yes Polystick TU Yes Yes See es 5.Polystick No Yes Yes TU P Yes Yes See es 5.Polystick No Yes Yes TU Plus Yes Yes See es 5.Polystick Yes Yes Yes TU Max No Yes See es 5.Dual No No No Pro Yes Yes No Yes Yes Yes Tile Pro Yes Yes See 554.1 Ye Yes Yes Yes Elastoflex S6 G Yes Yes Yes See 5.4.1 No Yes Yes Elastoflex S6 G FR Yes Yes No No Yes Yes Polyflex G Yes Yes Yes See 5.4.1 No Yes Yes Polyflex G FR Yes Yes No No Yes Yes Polyflex SAP or SAP FR Yes Yes See es 5.Mule-Hide No Yes Yes SA-APP Cap Sheet Yes Yes Yes No Yes Yes or SA-APP Cap Sheet (FR) See 5.4.1 5.4.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives unless tensile adhesion / long term aging data from an accredited testing laboratory is provided. ➢ Polyfoam PolyPro AH160: Polystick TU, Polystick TU P, Polystick TU Plus, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR) or Tile Pro. ➢ 3MTm 2-Component Roof Tile Adhesive AH-160: Polystick TU Max ➢ Dow TileBond: Polystick TU P, Polystick TU Plus, Polyflex SAP or Tile Pro ➢ Convenience Products' Touch 1n Seal StormBond Roof Tile Adhesive: Polystick TU Plus, Polystick TU Max 5.4.2 For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the tile. 5.4.3 A 2-ply underlayment system, consisting of Polystick MTS followed by Polystick MTS, TU, TU P, TU Plus or TU Max, or Polyflex SAP is allowable for use under mechanically attached prepared roof systems. This is not a requirement, but is allowable if a 2-ply underlayment system is desired. Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1113 Certificate of Authorization #9503 FL5259-1118 Revision 13: 04/26/2013 Page 4 of 10 V TRINITY I ERD 5.5 Allowable substrates are noted below: 5.5.1 Direct -Bond to Deck: Polystick (all variations), Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: ➢ New untreated plywood; ➢ ASTM D41 primed new untreated plywood; ➢ Existing plywood; ➢ ASTM D41 primed existing plywood; ➢ New or existing, unprimed OSB; ➢ ASTM D41 primed OSB; ➢ Southern Yellow Pine; ➢ ASTM D41 primed Southern Yellow Pine; ➢ ASTM D41 primed structural concrete; ➢ Huber Engineered Woods "ZIP System" Panels (designed and installed to meet wind loads for project). Note: Polyglass does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes. Elastoflex S6 G or S6 G FR in hot asphalt to: ➢ ASTM D41 primed structural concrete. Polyflex G or G FR torch -applied to: ➢ ASTM D41 primed structural concrete. 5.5.2 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI 07320 does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI 07320 and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609.1.5 for determination of design wind pressures. 5.5.2.1 Maximum Design Pressure = -622.5 psf. Deck: Structural concrete to meet project requirements to satisfaction of AHJ. Primer: ASTM D41 Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch - applied. 5.5.2.2 Maximum Design Pressure = -315 psf. Deck: Structural concrete to meet project requirements to satisfaction of AHJ. Primer: ASTM D41 Underlayment: Polystick TU, Polystick TU P, Polystick TU Plus, Polystick TU Max, Tile Pro, Polyflex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR). 5.5.2.3 Maximum Design Pressure = -135 psf. Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Primer: (Optional) ASTM D41 Joints: Min. 4-inch wide strips of Elastoflex SA-V over all plywood joints. Underlayment: Polystick TU, Polystick TU P, Polystick TU Plus, Polyflex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R13 Certificate of Authorization #9503 FL5259-RlS Revision 13: 04/26/2013 Page 5 of 10 F)o TRINITY � ERD 5.5.2.4 Maximum Design Pressure = -90 osf. Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AH]. Primer: (Optional) ASTM D41 Underlayment: Polystick TU, Polystick TU P, Polystick TU Plus, Polyflex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) 5.5.2.5 All other direct -deck, adhered Polyglass underlayment systems beneath foam -on tile systems carry a Maximum Design Pressure of -45 psf. 5.5.3 Bond -to -Insulation: ➢ Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: ASTM C1289, Type II, Class 1 polyisocya nu rate or Type V polyisocyanurate-composite insulation; DensDeck DuraGuard; DensDeck Prime; or SECUROCK Gypsum -Fiber Roof Board. ➢ Elastoflex S6 G or S6 G FR in hot asphalt to: DensDeck Prime or SECUROCK.Gypsum-Fiber Roof Board. ➢ Polyflex G or G FR torch -applied to: ASTM D41 primed structural concrete; DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on the systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4470, Appendix K or TAS 114, Appendix I 5.5.4 Bond to Mechanically Attached Base Layer: ➢ Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or Tile Pro self -adhered to: ASTM D226, Type I or II felt; Elastobase; Elastobase P or Mule -Hide Nail Base. ➢ Elastoflex S6 G or S6 G FR in hot asphalt to: ASTM D226, Type I or II felt; Elastobase; Elastobase P or Mule -Hide Nail Base. Polyflex G or G FR torch -applied to: Elastobase; Elastobase P or Mule -Hide Nail Base. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam -on tile systems, base layer shall be attached per minimum requirements of FRSA/TRI 07320/8-05 or RAS 120. 5.6 Exposure Limitations: 5.6.1 Elastobase, Elastobase P, shall not be left exposed for longer than 30-days after installation. 5.6.2 Polystick IR-Xe, Polystick TU Max, Dual Pro or Tile Pro shall not be left exposed for longer than 90-days after installation. 5.6.3 Polystick MTS, TU, TU P or TU Plus shall not be left exposed for longer than 180-days after installation. 5.6.4 Polyflex SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure limitation, unless the prepared roof covering is to be adhesive -set tile, in which case the maximum exposure is 30 days. 5.6.5 Elastoflex S6 G or S6 G FR or Polyflex G or G FR does not have an exposure limitation, unless the prepared roof covering is to be adhesive -set tile (Elastoflex S6 G or Polyflex G), in which case the maximum exposure is 180 days. Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R13 Certificate of Authorization #9503 FL5259-1138 Revision 13: 04/26/2013 Page 6 of 10 OT 30 Z 96ed £TOZ/9Z/b0 -ST uoisiAab STU-6SZSld £R1-60'Z0'090ZTd ;jodab uoi;enleA3 E096# uogezuoq;ny/o aleaUgJao •011 'u6isoa pue yoJeasab aoIJa;x3 WA 4aa4S deb ddV-VS Jo;aa4S deb ddV-VS 9PIH-91nW :ad al!1 !ldd dVS ;uawAepapun Jo dVS x89Alod 'xeW n1 !snld nl •d nl fnl m:),IsAlod :aaAe� dol P-94PV-;IDS / 0£ 'ON dZ0'£ b wa;sAS aseg IleN ap!H-alnW ;uawAeNapun 'd asego;sel3 'asego1sel3 !II adAl'9ZZO W1SV uaAe-j aseg paleaS 'al!l;aS-anlsa4PV (Ldd);aa4S deD ddV-VS Jo;aa4S deD ddV-VS aPIH-ainW 'ad a1!L ;uawAepapun OUT £ ; g ono a;s g ad dVS 30 dVS xal;Alod :xeW n1 !snld nl •d Ill !nl >lo!;sAlod PBIa4PV-;IaS 9 xal;Alod Jo 9 9S x9gapel3 :uaAen dot 4884S VZO'E T d asego;sei3 'asego;sel3 !II adAl'9ZZQ W1SV :jaALq aseg deb paUlpoW / 0£ 'oN (Lid) 1984S deb ddV-VS -104a94S deg ddV-VS aP!H-alnW :ad 9l!1 •lid dVS un Jo dVS xaOAlod !xeW n1 'snid nl !d nl fnl )lo!;sAlod :.jaAe-1 dot pa�a4PV �I S / 0£PoN 3Z0'£ s wa;sAS aseg I!eN ap!H-alnW ;umAel-pun !d asego4sel3 'asego4sel3 'II adAl'gZZO W1SV :jaAel aseg paleaS (Lid) 1994S deD ddV-VS Jo;aa4S deD ddV-VS aPIH-alnW `.oad 9i!1 ;uawAepapun 4Z0'E t4 jo paleasun 'Ldd dVS uo dVS -UAlod :xeW n1 !snid nl fd nl !nl )lo!IsAlod Pau94PV-II9S '91!148S-aAIs94PV :,•V ano3 wars s 9 xDl;Alod Jo 9 9S x9l;o;sel3 :jaAe-I dol 4984S SWE Z d asego:pe13 !asego3,sel3 :ja4e-1 aseg deo pag!poW / OE 'ON 9 xa9Alod Jo g 9S xa(;o;se13 49a4S deb paU!poW VZO'£ T oad 81!1 :ad len4 (Lid) 1994S deg ddV-VS jo;aa4S deD ddV-VS aPIH-ainW "U dVS ;uawAepapun Jo dVS -UAiod 'xeW n1 'snid nl •d nl 'nl)iollsAlod :uaAe-I dol Pa-la4PV-;IDS / OE 'oN 3Z0'£ S aseg l!eN ap!H-alnW :d asego;se13 :9sego4sei3 •II adAl'9ZZ4 W1Sv :jaAL9 aseg wD;sAS oad 9l!1'oJd ;uawAepopun ;uawAepapun lend !(2d3) ]aa4S deg ddV-VS uo;aa4S deJ ddV-VS aP!H-alnW pa-ia4PV-;Ias 4Z0'E b paleaS !2dd dVS Jo dVS XBUAlod •xeW nl :snld nl'd nl'ni�:)i:sAIOd 'al!1 paua4se3 Alleominjoew LJd g.10 9 xal;Alod =Ldd 9 9S x9do;sel3 jo 9 9S xaldo;se19 :jaAe3 dot 894S deb pai ! o 4 P W / OE 'ON 9Z0'E Z ° 1�a-s d asego4se13 :asego;sel3 uaAen aseg Aluo Ld 9 uo 9 xal;Alod f dd 9 9S x9gapei3 jo 9 9S x9l;o4sel3 4994S deD pag!poW ua:peg T VZO'£ ad DILL :o-ld lend '(Ldd) 10a4S deb ddV-VS jo;aa4S deJ ddV-VS aP!H-alnW "dd dVS jo dVS ;uawAepapun xallAlod !xeW n1 :snid nl •d nl !nl •S1W )lopsAlod :aaAel dot PEua4PV-blas / OE 'ON dZ0'E 9 aseg HRN DP!H-alnW !d asego:pel3 :asego;sel3 'II adAl'9ZZ4 W1SV :.jaAe-1 aseg wegsAS ad 9111 •oad lend ;uawAepapun ;uawAepapun !(Lij);aa4S de:)ddV-VS uo;aa4S deg ddV-VS aPIH-alnW ',dd P9-Ja4PV-;IDS 3Z0'£ S paleaS dVS Jo dVS xal;Alod !xeW nl !snld nl 'd nl •nl !S1W )lo!IsAlod uo paleasun 91!1 paua4se3 Alleopepow d asego;sel3 Iasegolse1@ OE 'ON 4Z0'E ti Lid 9 uo 9 xegAlod ! dd 9 9S xa904se13 Jo 9 9S xa0o;sel9 :.jaAe3 dol deb pag!poW / 0£ a4N 9Z0'£ Z 'a p�AS d asego;sel3 !asego;se13 :jaAe� aseg Aluo ad 9 uo g xaOAlod •Lid 9 9S x9go4se13 -jo 9 gS xaljo;sel3 ;a94S deb pag poW mpeg T VZO'E (s)13npoJd 83uaJa;aa uol;oas uiapu AeI�epun wa;sAs So-9/oZELo ru.L/vsusi jad suoi;do wa;sAS all.L :z algel •swalsAs jooi alit 4jeauaq pasn s4uawAelaapun 6uila4Pe-jlas ioj suoi}eliwil ioj„TTOZ/tT/ZO jo se squawa.!inbad juawAeiiapun pala4Py-jiaS aia food pulm 461H eppoij„ pallid jaug leoiu4:)al RIl/VSb=l a44 o4 @pew si a:)ua.dajad 6uimolloj a44 o} pa4iwil si asn 'uoi;ip3 4:Inoj 'lenueW uoilelleisuI SO-8/OZELO RIl/VS'dd aqj Aq pau.lanob suoilellelsui 3ooi apl Joj aa3 l JILINlI11 J� L'S noJTRlrni-YIERD 6. INSTALLATION: 6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 Elastobase. Elastobase P or Mule -Hide Nail Base: 6.3.1 Shall be installed in compliance with the codified requirements for ASTM D226, Type II underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.3.2 For use in non -tile applications: 6.3.2.1 Reference is made to the current edition of the NRCA Steep -slope Roofing Manual and ARMA recommendations for installing shingle underlayments and flashings 6.3.2.2 Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), Dual Pro or Tile Pro, self -adhered, Elastoflex S6 G or S6 G FR in hot asphalt or Polyflex G or G FR, torch applied. 6.3.3 For use in the applications, reference is made to Polyglass published installation instructions in conjunction with FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein. 6.4 Polystick MTS IR Xe TU TU P TU Plus TU Max Polyflex SAP or SAP FR Mule -Hide SA-APP Can Sheet or SA-APP CaD Sheet (FR). Dual Pro or Tile Pro: 6.4.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.4.2 For non -tile applications: 6.4.2.1 All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) should be back -nailed in selvage edge seam in accordance with Polyglass / Mule -Hide Back Nailing Guide. Nails shall be corrosion resistant, 11 gauge ring -shank type with a minimum 1-inch diameter metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back - nailed using the above noted fasteners and spacing, in area marked "nail area, area para clavar" on the face of membrane. The head lap membrane is to cover the area being back - nailed 6.4.2.2 All seal -lap seams (selvage laps) must be firmly rolled with a minimum 28 lb. hand roller to ensure full contact and adhesion. For Dual Pro and Tile Pro, align the edge of the top sheet to the end of the glue pattern (the sheet will overlap the fabric). Exterior Research and Design, LLC. Certificate of Authorization #9503 A• r qNZ Ri +.lf wax yy 4 �, a^ � X View of Ovelap Seam of Dual Pro and Tile Pro Evaluation Report P12060.02.09-11113 FLS2S9-R18 Revision 13: 04/26/2013 Page 8 of 10 J F)O I \I TRINITY ERD 6.4.2.3 All over -fabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Polystick TU Plus Tile Underlayment Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Electrometric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic, applied in between the application of the lap. 6.4.2.4 Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details 6.4.2.5 Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Polystick TU Plus Tile Underlayment Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic to the area in need of repair, followed by a minimum 6 x 6 inch patch of the Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be installed in a water shedding manner. 6.4.2.6 All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied for the field membrane. Hand rollers are acceptable for rolling of patches, laps (min. 28 lb roller) or small areas of the roof that are not accessible to a large roller or broom. 6.4.3 For tile applications (not allowed for Polystick IR-Xe): 6.4.3.1 Reference is made to Section 6.4.2 herein in conjunction with FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein, using the instructions noted above as a guideline. 6.4.3.2 For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the tile. 6.5 Elastoflex S6 G or S6 G FR: 6.5.1 Elastoflex S6 G or S6 G FR shall be installed in compliance with current Polyglass published installation requirements. For use in the applications, reference is made to FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein. 6.5.2 Elastoflex S6 G or S6 G FR shall be fully asphalt -applied to the substrates noted in Section 5.5. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, and off set end - laps minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge. 6.6 Polyflex G or G FR: 6.6.1 Polyflex G or G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications, reference is made FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein. 6.6.2 Polyflex G or G FR shall be fully torch -applied to the substrates noted in Section 5.5. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, and off set end -laps minimum 3 feet from course to course. Side and end laps shall be fully heat -welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge. Exterior Research and Design, LLC. Certificate of Authorization #9503 Evaluation Report P12060.02.09-1113 FL5259-R18 Revision 13: 04/26/2013 Page 9 of 10 F)o `J TRINITY I ERD 6.7 Tile Staaina: 6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Polyglass published requirements for tile staging. 6.7.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRI 07320/8- 05 must be used on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or nail -boards, to prevent tile sliding and/or damage to the underlayment during the loading process. 6.7.3 For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the tile. 6.7.4 The minimum cure time after installation of self -adhering membranes and before loading of roofing tiles is forty-eight (48) hours. 7. LABELING: Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. S. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL, LLC — QUA9625; (314) 578-3406; k.chancellor@us.ul.com Exterior Research and Design, LLC. Certificate of Authorization #9503 - END OF EVALUATION REPORT - Evaluation Report P12060.02.09-1113 FL5259-RlS Revision 13: 04/26/2013 Page 10 of 10 Florida Building Code Online Page 1 of 2 g n F lorida Deprimentg f BCIS Home Log In User Registration Hot Topics Submit Surcharge ( Stats & Facts j Publications FBC Staff i BCIS Site Map links j search Business`} OulProfessi ` aI Product Approval USER: Public User Regulation FMIRMOMMOMMM Product Approval Menu > Producttry �or.Aoolication Search > Application List > Application Detail FL # j ��Y FL10674-R8 Application Type 1 `r Revision Code Version �� 2010 Application Status , Approved Comments y Archived �� v Product Manufacturer Owens Corging; t r: Address/Phone/Email One Owens' Corning, -Parkway Toledo, OH 43659{"J (740)404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo, OH 43659 (419)376-8360 mel.sancrant@owenscornig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who Robert J.M. Nieminen developed the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 09/26/2014 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL10674 R8 COI Trinity ERD CI - Nieminen.pdf Referenced Standard and Year (of Standard) Standard Year ASTM D3161, Class F 2006 ASTM D3462 2007 ASTM D7158, Class H 2O07 Equivalence of Product Standards Certified By http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5 V%2b... 8/7/2013 Florida Building Code Online Sections from the Code Product Approval Method Date Submitted Date Validated Date Pendinb FBC Approval Date Approved Method 1 Option D 12/19/2012 12/20/2012 12/25/2012 02/04/2013 Page 2 of 2 ................................................................... . Summary of Products FL # 71 M[odel, Number or Name IlDescription 10674.1 Owens Corning Asphalt Roofing 3-tab, laminated, starter, and hip & ridge Shingles and Starters Limits of Use, Installation Instructions Approved for use in HVHZ: No FL10674 R8 II er121912FINAL OC Asohait Approved for use outside HVHZ: Yes Shingles FL10674-R8.odf Impact Resistant: N/A Verified By: Robert J. M. Nieminen PE - 59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to ER, Section S. Evaluation Reports FL1.0674 R8 AE er].21912FINAL OC Asohalt j Shingles FL10674-R8.Ddf Created by Independent Third Party: Yes Back Next Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Coovrlaht 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: go 9 zRImtF - SBCtYYItYAi3 r%it(.`S' http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5 V %2b... 8/7/2013 EXTERIOR RESEARCH & DESIGN, LLC. k Certificate of Authorization #9503 j ? -,, 353 CHRISTIAN STREET, UNIT #13 Q0Ta1NrrYJERD , s OXFORD, CT 01111 PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT Owens Corning Evaluatin Report 037940.02.12-R2 One Owens Corning Parkway FL10674-118 Toledo, OH 43659 Date of Issuance: 02/06/2012 Revision 2: 12/19/2012 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2010 FBC and 2010 FBC Residential Volume sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 12/19/2012 This does not serve as an electronically signed document. Signed, sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. TrinitylERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. F)o TRINITY I ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2007 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161, Class F 2006 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158, Class H 2O07 3. REFERENCES: Entity Examination Reference Date UL LLC (CER9626) Physicals & Wind Resistance File R2453, Vol. 3 02/15/2007 UL LLC (CER9626) Physicals & Wind Resistance 20120516-R2453 05/16/2012 UL LLC (TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC (TST9628) Wind Resistance 11CA34308 02/18/2012 Miami -Dade (CER1592) FBC HVHZ Compliance 07-1116.12 02/14/2008 Miami -Dade (CER1592) FBC HVHZ Compliance 09-0915.12 12/16/2009 Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.09 10/27/2010 Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.10 10/27/2010 Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.08 10/27/2010 Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.07 10/27/2010 Miami -Dade (CER1592) FBC HVHZ Compliance 11-0411.03 06/16/2011 Miami -Dade (CER1592) FBC HVHZ Compliance 12-0309.01 07/19/2012 UL LLC (QUA9625) Quality Control Service Confirmation R2453 Exp. 09/26/2014 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic° and Supreme° are fiberglass reinforced, 3-tab asphalt roof shingles. 4.1.2 Berkshire° are fiberglass reinforced, 4-tab asphalt roof shingles. 4.1.3 Duration°, TruDefinition° Duration°, Duration° Premium Cool, TruDefinition° Duration° Designer Color Collection, TruDefinition® OakridgeO, OakridgeO and WeatherGuard° HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Berkshire° Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuard° HP Hip & Ridge Shingles and ProEdge Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.3 Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. 5. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ. 5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.3 Wind Classification: Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R2 Certificate of Authorization #9503 FL10674-RS Revision 2: 12/19/2012 Page 2 of 6 (-)o I ERD 5.3.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for us in all wind zones up to Vasd = 150 mph (V,it = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.3.2 All Owens Corning hip & ridge shingles and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for us in all wind zones up to Vasd = 150 mph (V,lt = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.3.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.3.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.4 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 9N-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 9N-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: ➢ Berkshire® shingles require minimum five (5) nails per shingle. ➢ WeatherGuardO HP shingles require minimum six (6) nails per shingle. ➢ Starter Strip Plus requires minimum five (5) nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. 6.2.5 Minimum Nailing — Classic@ & Supreme: worme Mansard or Area pnro Wind Arose High Wind dasvanes y Area pare vienros normales Areas vierrtoa !mart.. �" lAl � �t z• iBi Z' r rr S"Exposure Exposicidn Exterior Research and Design, LLC. Certificate of Authorization #9503 Normal Mansard or Araa.para Wind Area High Wind doavarros y Aran pare vientoe normalas Areas vientoa fuartes (t" 5 G1W Exposure Exposicidn Evaluation Report 037940.02.12-R2 FL10674-RS Revision 2: 12/19/2012 Page 3 of 6 6.2.6 Minimum Nailing - Berkshire@: TTRINITYIERD Sealantstdp La grade seftbr �t—�►fi r--Y • 09- ---1• 8.1/P 9IV B 1/f a iff 7" r r' r. Asphah roofing oement Cemeoto de techo deastalto 6.2.7 Minimum Nailing - Duration@, TruDefinition@ Duration, Duration@ Premium Cool & TruDefinition® Duration° Designer Color Collection: 6Nat WeeattwrenSu read° Pattern attaanatop afwtoN: Esquema — A•nsaNa oPand6 aes de 6 davos aan"a B e • • • 2raaSaeeaaa ytl park. Sarenai° \ Sut6eaila fatteni tadenk�9 areaw'�tfi- � - 'ane wi0ffi brzadz rcam �E ENEMA, S 9e +� 7T ` ^ ST' ~ 9ueliaiA 5W Expcsure Nags 5V ExpOSM 9h padg. do exposkOn Claws 3'b putg. do wposid& 6.2.8 Minimum Nailing — TruDefinition® Oakridge@, Oakridge@: 4 Nag Mom Esquema car 0 daws r r IE— 14— rr 5 Sir Exposure Nails 5 5JT ExposuF3 Erpo4da7de66/ftpulg Ciasos E*usfddnde55/8pdg. Exterior Research and Design, LLC. Certificate of Authorization #9503 6 Nall Pattam Esquema son 6 daros r r Nails ils 5 5A" Exposure 5BIB" Fxpeuure Cla Expesiadn de 6¢/1?pdg. Expasieicn da $6l8 Evaluation Report 037940.02.12-112 FL10674-R8 Revision 2: 12/19/2012 Page 4 of 6 6.2.9 Minimum Nailing - WeatherGuard@ HP: .ti} •: r. =19 ildr Vbw vre. dm.� F�e7lnu�r Nil � I¢r�trl�i4dlla (_,�o \l TRINITY I ERa 6.3 Hip & Ridge Shingles: 6.3.1 Installation of Berkshire° Hip and Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuard° HP Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using four (4) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand -sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing — Berkshire@ Hip & Ridge and High Ridge: Fig. i q F— PrelruGngwnd Direction A 4 A 1 I I I ♦ A 4 I I I I I I I 1 A l j 1 I 9"—>l ♦7(�IeSllre 6.3.4 Minimum Nailing - Hip & Ridge with Sealant: em Fig. 2 - High Witld Fastening pattem (4.11lads), rim Shingle—► nd Discard 2" 2" a 1u 1a Sealant —• Strip . • 110 ' Fastening. �r5/e 5"Exposure Distance 12" Exterior Research and Design, LLC. Certificate of Authorization #9503 Fig. 2 TdpXhmv Sidemen Nails Nails Tap Laninalell 2" � 4" Piece f I I ml cl JI �I ml ul I I. I I Evaluation Report 037940.02.12-112 FL10674-R8 Revision 2: 12/19/2012 Page 5 of 6 6.3.5 Minimum Nailing — WeatherGuard@ HP Hip and Ridge: Fig. A 9 q PrmEng Wind �— Dlredbn - A A Hans q q A i I p I I 44 I I I I I I I t AA i j I I I I + W Exp�s—� osure `J TRINITY I ERD Fig. C Hip & Ridge Shingle Fastening TopVbw Halls NaUs 72. 1° 1° 1 �• g Exposure I 12° 6.3.6 Minimum Nailing - ProEdge Hip & Ridge Shingles: Prevailing Wind Direction Sealant Strip r'-" G' Exposure Fasten TW Cover Exposed Fasteners with Roof Cement \ Standard —tt„_� Fastening Pattern t2` 1 Sealant 7 h� 6° Exposure 7. LABELING: 7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. S. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC- QUA9625 ; (414) 248-6409; karen.buchmann@ul.com - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R2 Certificate of Authorization #9503 FL10674-R8 Revision 2: 12/19/2012 Page 6 of 6