HomeMy WebLinkAboutSUBMITTED PAPERSDate:
Fee
_�I Permit #
�a
St. Lucie County Building & Zoning
2300 Virginia Avenue Ft. Pierce, FL 34982-5652 Sc
Tel.561-462-1553 5't
SPECIALTY PERMIT APPLICATION �Uo'o Co
only
❑ Electrical Plumbing ❑ HVAC ❑ Fence
❑ Shed ❑ Demolition ❑ Gas ❑ Siding
See page 2 for instructions and additional paperwork required for specialty permits
1. Location/Site Address:
I-ivv, Or. R" S+Lul.l.-erFL-
2. Parcel IDS Number: 3 H o-I -7 - 701 -000 3 -- 3
3. Description of Project or Work Activity:
�('
� 6011
Poo �
Pt -" � V, C
Office Use
Section
Townshi
Range
Ma Page
Zoning
Land Use
I "ti
Only
4. Owners Information 5. �C�ontra�ctors Information
Name: _ d i; �1`& ReglC-ert #: C� C, �-rl in(() S7
Address: boot S E 0;d�et� �Je��� CountyCert#: 9D57
City: P� S-k Ll t,�, j State: F-L Business Name: �`a-Ir jwCpA
Zip: 4 g 3 Phone: �p aaq 5 Phone �-tCU►�-fr �G{03 Fax L46(o %
6. Value of Construction: $ �j00
OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done
in compliance with all applicable laws regulating construction and zoning. A It
�ec+Zrai(ad4
PRINT QUALIFIERS/OWNERS NAME r SIGNATURE OF QUALIFIER/UWNl;K
STATE OF FLORIDA, COUNTY OF ACKNOWLEDGED BEFORE ME THIS c?'Cj D AY OF
20a BY �R r) YJQ.f't Z VO4 I 1ufiK. WHO IS PERSONALLY KNOWN TOME OR WHO HAS PRODUCED
' AS IDENTIFICATION.
(seal)
SIGNATURE OF NOTARY TYPE OR PRINT NAME OF NOTARY
TITLE: NOTARY PUBLIC
St. Lucie County Specialty Permit Application rev. 8/25/05 dmg
COMMISSION NU B :R
,.��P`8��,' AMBER FRANKLIN
o�
Notary Public -State of Florida
My Comm. Expires Oct 31, 2014
Commission # EE 7947
Bonded Through National Notary Assn.
Property Appraiser - St.Lucie".znty, FL Page 1 of 1
Edmond Alonzo III
Record: 1 of 1
Property Identification
Site Address:
609 SE HIDDEN RIVER DR
SeclTown/Range:
27 :36S :40E
Map ID:
34/27S
Zoning:
RS-3
PROPERTY RECORD CARD
<<Prev, Next»
Spec.Assmnt Taxes
Exemptions Permits Home Print
ParcellD:
3427-701-0003-000-3
G,L
Account #:
115483
y4
Use Type:
SF Res
1 j
City/Cnty:
Saint Lucie County��
Ownership and Mailing Legal Description
Owner: Edmond Alonzo III Katharine A Alonzo HIDDEN RIVER ESTATES BLK 1 LOT 2 AND 27 36 40 BEG AT NE
Address: 609 SE Hidden River Dr COR LOT 2 BLK1 HIDDEN RIVER EST,TH RUN N 89
Port St Lucie FL 34983-2739 More...
Sales Information
Assessment 2012
Total Land and Building
Date
Price
Code
Deed
Book/Page
2012 Final:
392200
Land Value: 194500 Acres: 0.72
1/3/2011
481800
0001
WD
3270 / 0001
Assessed:
392200
Building Value: 197700
8/31/1992
275000
00
WD
0805 / 2301
Ag.Credit:
0
Finished Area: 3640 SgFt
1/1/1986
69900
00
CV
0488 / 1293
Exempt:
50000
7/1/1978
22000
01
CV
0291 / 1322
Taxable:
342200
5/1/1978
0
01
CV
0286 / 1827
Taxes:
7117.43
BUILDING INFORMATION
Exterior Features
View: -
RoofCover:
TC - Clay Tile
RoofStruct:
HP - Hip
ExtType: HB+ - HB+
YearBlt:
1988
Frame:
Grade: B+ - B+
EffYrBlt:
1988
PrimeWall:
BS - CB Stucco
StoryHght: 0010 -1 Story
No.Units:
1
SecWall:
Interior Features
BedRooms: 4
Electric:
MX - MAXIMUM
PrmintWall:
DW - Drywall
FullBath: 3
HeatType:
FHA - FrcdHotAir
. AvgHUFI:
1 /2Bath: 0
HeatFuel:
ELEC - Electric
Prm.Flors:
CT - Tile -Ceramic
%A/C: 100
%Heated:
100
%Sprinkled:
0
Special Features and Yard Items
Land Information
Type Y/S Qty.
Units Qual. Cond.
YrBit.
No. Use Type
Type
Measure Depth
DOK1 - CONC DOCK Y 1
396 AV AV
1988
1 0100-SF Res
SFI -Front Ft
120 170
SWAV - RES POOL AVG Y 1
364 AV AV
1988
2 0000-Vac Res
120 -Unit
1
PA01 - POOL DK-AVG Y 1
1682 AV AV
1988
ENC2 - POOL ENC-AVG Y 1
2046 AV AV
1988
DWC - Driv-Concret Y 1
1020 AV AV
1988
FEN4 - CHAINLINK 4' Y 1 150 AV AV 2001
THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED.
http://www.paslc.org/paslc/prc.asp?prclid=342770100030003 8/7/2013
Collector Rating Search 1jv �) Page 1 of 1
FSEC Collector Search FILE COPY
Instructions: Fill in as many values as desired to select partial or full listings and click on Show Selections.
FSEC Id:
Collector Type: Select Collector Type +
Company: Heliocol USA, Inc.
+
Show Selections
Show in Excel
Reset to Default
Ratings Summary Of FSEC Certified Collectors
03/11/2013
Click on a FSEC
Number to see the full page Collector
report.
Thermal
Thermal Thermal
Collectors
Glazing Absorber
Gross Performance
Low
performance er Pformance Thermesiphon
Intermediate High
Area Temperature
Temperature Temperature or ICS
Rating
Rating Rating
Cgmpany
No
Heat
Btu/DaY BW/ftz' Btu/Day gW/ftz Btu/Day Btu/ftz loss
Energy eff
HeOocol
Polypropylene
Hell, Inc TC 30
0 None with W
None 29.42 25000 850
9700 330 0 0
stabilization
Htlbcol
_ Polypropylene
USA, line. TC 40
0 one with al
None 41.41 35200 850
13700 330 0 0
stabilization
Hdbcol Chromagen
Tempered Copper tubes
USA, Inc CA110
1 low -Iron welded to
Selective 25AS 24400 960
19100 750 5500 220
glass copperfins
Hell cal
Tempered Copper tubes
USA, Inc. Alpha 32
1 low Iron welded to
Selective 31.98 30900 970
24200 760 70M 220
•
glass copper fins
Hdlocol
Tempered Copper tubes
USA, Inc. Alpha 40
1 low iron welded to
Selective 40.06 38500 960
30100 750 8700 220
glass copper fins
Htlbcol
Polypropylene
USA, TC 50
0 None with W
None 48.6 41300 850
I6100 330 O 0
stabilization
Hdl000f
ol
Polypropylene
Hell, Hellocol 38
O None with W
None 36.68 35100 960
12600 340 0 0
stabilization
Htlioml
Polypropylene
tfell Hdiecol 40
0 None whh W
None 40.68 38900 960
14000 340 0 0
stabilization
Hdbml
Polypropylene
4 "
ISO
0 None with W
None 48.23 46100 960
16500 340 0 O
-stabilization
stabilization
Htlbdol Sun Kiser
Polypropylene
USA Inc. 40
0 None with W
None 40.68 38900 960
14000 340 0 a
stabilization
Hdloml Sun Kiser
Polypropylene
USA Inc. 50
0 None with W
None 48.23 46100 960
16500 340 0 0
stabilization
Iltllocol
Polypropylene
HSA, nl Hellocol 30
O. None with UV
stabilization
None 29.15 27900 960
10000 340 0 0
INZ
Solar Collecfors
Asch
0? q6
PVC,
Feed Line
Vacuum Breaker
ISO;
P01"el Connectors 0!1 R,00',
Automatic
Control
(op;..—-t--MiIo
n.al) L R
etum Line
Sensor ;irWire
Wire
I
Ball Valve
Backup
Heater
(optional)
Front�ooi
Filter
To Pool
..........
r
y(M
HELIOCOL COLLECTOR CONCRETE TILE - TILE
ADHESIVE GENERAL NOTES:
Q
h 1. APPLICABLE CODE: 2010 FLORIDA BUILDING CODE & ASCE-7-10 MINIMUM DESIGN LOADS FOR
L
1" X 1" X 2 Z" - i "ALUM.
2 -16
o BUILDING AND OTHER STRUCTURES.
6063T6 Z-BAR SHAPE
z 2. PLANS ARE IN ACCORDANCE WITH 2O10 FLORIDA BUILDING CODE AND PER MIAMI DADE NOA 12-0228.18.
0 3. POLYPRO ROOF ADHESIVE SHALL BE APPLIED IN COMPLIANCE WITH THE COMPONENT APPLICATION
WITH (1)1" DIA. -11"
9 SECTION AND THE CORRESPONDING PLACEMENT DETAILS NOTED IN THE NOA APPROVAL DOCUMENT
LENGTH TAPCON
0 AND THE 3M/POLYFOAM POLYPRO ROOF TILE ADHESIVE OPERATING INSTRUCTION AND MANUAL
STAGGERED AS SHOWN
BOOKLET.
THIS SHEET
W 4. TILE ROOF INSTALLATION AND UNDERLAYMENT SHALL COMPLY WITH LATEST FLORIDA BUILDING
z CODE AND ROOFING APPLICATION STANDARD RAS 120.
5.3M/POLYFOAM POLYPRO ROOF ADHESIVE COMPLIES WITH THE FOLLOWING CODES: 2010 FLORIDA BUILDING
CODE, SOUTH FLORIDA BUILDING CODE BROWARD COUNTY-1999, MIAMI DADE NOA 12-0228.18.
0 6. LOCATION OF COLLECTORS WITH 3M POLYFOAM ADHESIVE IS NOT TO BE INSTALLED IN WIND ZONE 3.
w
z
Owi
U V,
Wo
�Q
Op
a�
5 z
0
OU
z
�a
z
�O
oZ
�w
O;E
0-
o¢
z
¢W
z>
p
it
(L x
cew
O�
O�
3a
x
z�
po
UQ
oZ
ceO
w U
ow
w
�(D
N Z
�w
ww
m=
0
Z3
2z
N
N z
U�
o°
UU
Z w
o�
w O
pU
pLL
z�
<>
<Z
w3
cO
< N
zo
�LL
3r
�Z
z-
¢z
O
[X -
a
di
-p
Oz
Z.
WLu
Zvw
Z
uz
�Q
Np
7. CONNECTIONS AND SPECS PER THIS DRAWING MAYBE USED FOR ALL HELIOCOL COLLECTORS TO RESIST
WIND LOADS AS OUTLINED IN 2010 FBC, CHAPTER 16 FOR UP TO 175 MPH, EXPOSURES "B" OR "C" WIND
VELOCITY PER REQUIREMENTS STATED IN ASCE7-10.
3M/POLYFOAM POLYPRO -NOA SPECIFIC NOTES:
POLYPRO ROOF TILE ADHESIVE MUST BE APPLIED TO AN UNDERLAYMENT INSTALLED IN COMPLIANCE WITH
APPLICATION INSTRUCTIONS DETAILED IN THE FOLLOWING LATEST DOCUMENTS:
FRSA/ROOF TILE INSTITUTE ADHESIVE SET TILE SPECIFICATION.
3M/POLYFOAM ADHESIVE IS UL CLASSIFIED AS AN ADHESIVE MIAMI-DADE NOA 12-0228.18, EXPIRES
5/10/2017 - FLORIDA BUILDING CODE FL #6332-REV3.
LIMITATIONS OF MIAMI-DADE NOA FOR SPECIFIED TILE PROFILE - ADHESIVE BELOW:
1) FOR ADHESIVE SET TILE APPLICATIONS, A STATIC FIELD UPLIFT TEST IN ACCORDANCE WITH TAS 106
MAY BE REQUIRED, REFER TO APPLICABLE BUILDING CODE.
2) APPLICANT SHALL RETAIN THE SERVICES FOR A MIAMI-DADE COUNTY CERTIFIED LABORATORY TO
PERFORM QUARTERLY TEST IN ACCORDANCE WITH TAS 112, APPENDIX W. SUCH TESTING SHALL BE
SUBMITTED TO THE BUILDING CODE COMPLIANCE OFFICE FOR REVIEW.
3) MINIMUM UNDERLAYMENT SHALL BE IN COMPLIANCE WITH THE APPLICABLE ROOFING APPLICATIONS
STANDARDS LISTED SECTION 4.1 HEREIN.
4) THIS ACCEPTANCE IS FOR WOOD DECK APPLICATIONS. MINIMUM DECK REQUIREMENTS SHALL BE IN
COMPLIANCE WITH APPLICABLE BUILDING CODE.
TABLE 1: ADHESIVE PLACEMENT FOR EACH GENERIC TILE PROFILE PER MIAMI DADE NOA 12-'0228.18
CONCRETE ROOF TILE PROFILE
PLACEMENT DETAIL
MINIMUM SINGLE PADDY
WEIGHT (GRAMS)
FLAT / LOW / HIGH PROFILE
#1(PAGE 5 OF 7 IN NOA)
35
HIGH PROFILE (2 PIECE BARREL)
#1(PAGE 5 OF 7 IN NOA)
17 SIDE ON CAP AND 34 PAN
TYP COLLECTOR ROOF WIND ZONES
FOR HIP AND GABLE ROOFS -PLAN �1
�m,:_HC-6
HELIOCOL
COLLECTOI
TYP
1"x2'x21z"-is"ALUM.
6063T6 Z-BAR SHAPE
WITH (1) "' DIA. - 14
LENGTH TAPCON
STAGGERED AS SHOWN
THIS SHEET
END CAF
TYP.
TYPICAL (5) COLLECTOR ARRAY PLAN
SCALE: a"=1'-0"
1"x2'X2%"-16'ALUI
6063T6 Z-BAR SHAPE
WITH (1)1" DIA. -14'
LENGTH TAPCON
STAGGERED 12" O.C.
(SEE Z-BAR DETAIL)
CONNECTION IS REQ.,
LOW -PROFILE ALUM
UNISTRUT MAY BE USED &
FASTEN PER Z-BAR SPEC.
AS SHOWN. ATTACH
UNISTRUT TO TILE THRU
Z-BAR - (2) TAPCONS PER
HELIOCOL CLAMP
Eb
UNISTRUT ALUM.
LOW -PROFILE
CONTRACTOR MAY USE A LOW PROFILE ALUM. UNISTRUT TO PROVIDE SEPARATION
BETWEEN FLAT/LOW PROFILE TILE AND BOLT. CONTRACTOR TO VERIFY CONCRETE
TILE TYPE AND APPLY 3M ADHESIVE PER PLACEMENT DETAIL IN NOA TYP.
(2) #6 HEX SCREWS
-4'
LENGTH TYP
— (1)1" DIA. -1"
LENGTH ST. STL.
BOLT - WASHER
- NUT TYP.
l FLAT CONC.
TILE TYP.
1"x2'x21z"-16'ALUI
6063T6 Z-BAR SHAPE
WITH (1)1" DIA. -11"
LENGTH TAPCON
STAGGERED 12" O.C.
(SEE Z-BAR DETAIL)
& BOLT AT TILE VALLEYS
TO ENSURE ADEQUATE
SPACE FOR WASHER - NUT
APPLY 3M/POLYPRO ROOF TILE
#2 S.Y.P. ADHESIVE, OR EQUAL, TO ADHERE
WOOD ROOF BOTTOM SIDE OF TILE HELIOCOL
TRUSS TYP. CLAMP IS ABOVE TO PLUS ALL
OD
SHEATHING TILES AROUND IT (5 MIN.)
TYPICAL FLAT / LOW PROFILE CONCRETE TILE
ADHESIVE TOP & BOTTOM CONNECTION DETAIL
SCALE: 1"=V-0"
2
1" x 2' x 2 Y2" -16' ALUM. 6063T6 Z-BAR SHAPE (30"
MIN. SECTIONS) FASTENED WITH (1) 4" DIA. - 14'
LENGTH TAPCON 12" O.C.
SIN 22 I 31
2
TYPICAL MAR DETAIL
SCALE: 12'=1'-0"
b r. LUCIE COUNTY
BUILDING DIVISION
RIE v11=WE D
REVIEWED BY J' ►�
DATE D a
PLANS AND P RMIT
MUST BE KL"?T ON JOB OR
�Q IPJS c*r, •pg,1 13.A MAaX1
(2) #6 HEX SCREWS
r U
- 4" LENGTH TYP
- (1)1" DIA. 1"
LENGTH ST. STL.
BOLT - WASHER
- NUT TYP.
1
L - HIGH CONC.
TILE TYP.
-1"ALUM. -
: SHAPE TYP.
HELIOCOL CLAMP
SPACED 2'-0" O.C.
TYP.
1" DIA. -11" LENGTH
TAPCON STAGGERED
12" O.C. TYP.
---APPLY 3M/POLYPRO ROOF TILE
#2 S.Y.P. ADHESIVE, OR EQUAL, TO ADHERE
WOOD ROOF BOTTOM SIDE OF TILE HELIOCOL
TRUSS TYP. CLAMP IS ABOVE TO PLUS ALL
OD TILES AROUND IT (5 MIN.) TYPICAL Z BARHELIOCOL
SHEATHING
TYPICAL HIGH PROFILE CONCRETE TILE
ADHESIVE TOP & BOTTOM CONNECTION DET
fCALE: 1"=V-0"
:.
a
N
z
0
V
a
0
W
a
N
- -
CLAMP CONNECTION
DETAIL 5
SCALE: 1/2"=V-0" HC-6
�a
w
0
T� U 0
W
PROJECT #:
DESIGNED: REC 111309
SCALE: NOTED