Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SUBMITTED PAPERS
Fee Due• � Recei Permit # Planning P Se ces & Development 13q-to(o Building & Code Regulations Division 2300 Virginia Ave. SCA Fort Pierce, FL 34982 g �NEQ ® (772)462-1553 CUT CpU my SPECIALTY PERMIT APPLICATION ❑ Electrical ❑ Plumbing O HVAC ❑ Fence ❑ Shed ❑ Demolition ❑ Gas ❑ Siding See page 2 for instructions and additional paperwork requi redfor for specialty60e, permits /� 1. Location/Site Address: � `d-o -i—+ 'F0� &PI L 60 , RL 3YQ 9(0 2. Parcel ID Number: Office Use Only Section Township Range Map Page Zoning Land Use Initials 3. Complete Description of Project or Work: CM' " Y}.eM : CH6LL Ul0 U I," -LPN �V�AUo, In VA 1 r I r iL,e- - 4;� 119 96P 'kb 4. Owners Information 5. Contractors Information Name: V =b Lum, `' FL Reg/Cert #: NO, ono(OU Address: 1?QD6 (�(5+ I ; �-Ro .tC,l County Cert#: City: `�Y� �Ji' 1 ;1CJ State: �. Business,Name: P.\tJ(I �{2e- MCI e Zip: � � Phone: %Z-7;))44--(&Phone: 06-1(00to Fax: 6. Value of Construction: $ qSS OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in Corr with all applicable laws regulatin onstruction and zonnn �arnu�l 1. l>u /hare k PRINT OWNER OR CONTRACTOR NAME SIGNA�01.OR CONTRACTOR STATE OF FLORIDA, COUNTY OF `J"`� � rL ACKNOWLEDGED BEFORE METHIS UJW DAYOF 201�BY &rnu-e( T �llr�'l tY�las�:�afr ati� fff WHO IS PERSONALLY KNOWN TO ME V OR WHO HAS PRODUCED yaiy� PNNE F G SS AS IDENTIFICATION..o zk'0`uary2�02•�9l # ®° (seaI' m m cn ° IGNATURE OF NOT Y TYPE OR PRINT NAME OF NOTARY Y P A y oo�9gBr4 COACWSSIONNUMBER rsYP/ 4/G �� G•,A°oaPa 6 '1. aab//p thN o .a °® U sot, SpT •�pP,,�. NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YI Of�1�C �\TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CO SULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. EXEMPT: A/C -HEAT REPLACEMENT WITH CONTRACT UNDER $7500.00 Revised 04/26/2010 �o Project"bummary Entire House For: Joseph Lucchese, Advantage Air 8906 First Tee Road, Port St. Lucie, FL 34986 Email: 2shawnrussell@bellsouth.net Notes: Weather: Fort Pierce, FL, US Winter Design Conditions Outside db Inside db Design TD Job: 25896 Date: September 6, 2013 By: Russell Summer Design Conditions 43 °F Outside db 70 °F Inside db 27 °F Design TD Daily range Relative humidity Moisture difference Heating Summary Structure 25462 Btuh Ducts 8578 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 34040 Btuh Method Construction quality Fireplaces Infiltration Simplified Average 0 Heating Cooling Area (ftz) 2214 2214 Volume (ftl) 19926 19926 Air changes/hour 0.32 0.16 Equiv. AVF (cfm) 106 53 Heating Equipment Summary Make n/a Trade n/a Model n/a AHRI ref n/a Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat n/a 0 MBtuh 0 Btuh 0 °F 1900 cfm 0.056 cfm/Btuh 0 in H2O 90 °F 75 °F 15 °F L 50 % 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 28758 Btuh Ducts 17892 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 44317 Btuh Latent Cooling Equipment Load Sizing Structure 2220 Btuh Ducts 3950 Btuh Central vent (0 cfm) 0 Btuh Equipment latent load 6169 Btuh Equipment total load 50486 Btuh Req. total capacity at 0.70 SHR 5.3 ton Cooling Equipment Summary Make Rheem Trade RHEEM RASL SERIES Cond RASL-060JEC Coil RHPN-HM6024++RCSN-H*6024 AHRI ref 4262758 Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 12.0 EER, 18 SEER 39900 Btuh 17100 Btuh 57000 Btuh 1900 cfm 0.041 cfm/Btuh 0 in H2O 0.88 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 1 Wry htso , 2013-Sep-0614:56:40 � Rig Universal 2012 12.1.08 RSU09070 Page 1 �` CAUsers%Shawn%DccumentslAC LOADSt2200 SQ FT.rup Calc = MJ8 Front Door faces: SW Certificate of Product Ratings AHRI Certified Reference Number: 4262758 Date: 9/6/2013 Product: Split System: Air -Cooled Condensing Unit, Coil with Blower Outdoor Unit Model Number: RASL-060JEC Indoor Unit Model Number: RHPN-HM6024+RCSN-H*6024 Manufacturer: RHEEM MANUFACTURING COMPANY Trade/Brand name: RHEEM RASL SERIES Manufacturer responsible for the rating of this system combination is RHEEM MANUFACTURING COMPANY Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air -Conditioning and Air -Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): 57000 EER Rating (Cooling): 12.00 SEER Rating (Cooling): 18.00 * Ratings followed by an asterisk (*) indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectoryorg. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION The information forthe model cited on this certificate can be verified atwww.ahridirectoryorg, w "IMFAir-Conditioning, Heating, click on "'Verify Certificate" link and enter the AHRI Certified Reference Number and the date on A. On ta' and Refrigeration Institute which the certificate was issued, which is listed above, and the Certificate No., which is listed below. ©2013 Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130229567193193550 Wrighboft Project Summary --eaoter ay n"irn Entire House For. Joseph Lucchese, Advantage Air 8906 First Tee Road, Port St. Lucie, FL 34986 Email: 2shawnnissell@bellsouth.net Notes: Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Outside db Inside db Design TD Job: 26698 Date: September%W13 By: Russell Summer Design Conditions 43 OF Outside db 70 OF Inside db 27 OF Design TD Daily range Relative Humidity Moisture difference Heating Summary Structure 25462 Btuh Ducts 8578 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 34040 Btuh Infiltration Method Construction quality Fireplaces Simplified Average0 Heating Cooling Area (ft� 2214 2214 Volume (ft3) 19926 19926 Air changesthour 0.32 0.16 Equiv. AVF (cfm) 106 53 Heating Equipment Summary Make n/a Trade n/a Model n/a AHRI ref nfa Efficiency n/a Heating input 0 MBtuh Heating output 0 Btuh Temperature rise 0 OF Actual airflow 1900 cfm Air flow factor 0.056 cfm/Btuh Static pressure 0 in H2O Space thermostat 90 OF 75 OF 15 OF L 50 ova 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 28758 Btuh Ducts 17892 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btuh Use manufpcturees data n Rate/swing multiplier 0.95 Equipment sensible load 44317 Btuh Latent Cooling Equipment Load Sizing Structure 2220 Btuh Ducts 3950 Btuh Central vent (0 cfm) 0 Btuh Equipment latent load 6169 Btuh Equipment total load 50486 Btuh Req. total capacity at 0.70 SHR 5.3 ton Cooling Equipment Summary Make Rheem Trade RHEEM RASLSERIES Cond RASL4=JEC Coil RHPN-HM6024++RCSN-W6024 AHRI ref 4262758 Efficiency 12.0 EER, 18 SEER Sensible cooling 39900 Btuh Latent cooling 17100 Btuh Total cooling 57000 Btuh Actual air flow 1900 cfm Air flow factor 0.041 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.88 8oldpEr/le values have been manuelty ovenfddGn Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrilhttsoft - zols segos 1 Page 1 9 RIpMSuite® Unheersa12012 12.1.08 RSU09070 Page 1 .1& Q%UserslShaxnl0oamerdslAC LOADS%2200 80 FT.rup Cat = MJ8 Front Door faces SW