HomeMy WebLinkAboutSUBMITTED PAPERSi
Date: Fee Duel Receipt# rY%.l TPermit # _ /f &
Planning & Development Services
Building & Code Regulations Division
2300 Virginia Ave.
Fort Pierce, FL 34982
(772)462-1553
SCANNeD
SY
St. Lucie County
SPECIALTY PERMIT APPLICATION
❑ Electrical ❑ Plumbing Q"HVAC ❑ Fence
❑ Shed ❑ Demolition ❑ Gas ❑ Siding
See page 2 for instructions and additional paperwork required for specialty permits
1. Location/Site Address: t45LQ 1,n L c w C�i -&e_
2. Parcel ID Number: ( 31 a L4 c)(X) - 1
Office Use
Only
Section
Township
Range
Map Page
Zoning
Land Use
Initials
3. Complete Description of Project or Work:
'3 I -A T r\ A l � t d 1,
4. Owners Information 1 5. Contractors Information
Name: LAC6k A h, [ [ on 55
FL Reg/Cert #: i� , �l1.S-7 q [n
Address: 5(2 � ( � isy\ ke crw l/+ ud t, _ County Cert#: .2n D g
F
City: i ► i-bt- State: Business NName:. M I Aiyer1 c,.,, Aw -4 clr,,M e-
Zip: 54C c51 Phone: Zd Phone: ` `Sl �i. Fag: a 7 8'51y q r
6. Value of Construction: $ 9 969
owNEws AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in
compliance with all applicable laws regulating construction and zoning.
PRINT OWNER OR CON CTOR NAME SIGN WNER Ok CONTRACTOR
STATE OF FLORIDA, COUNTY OF �� r Lk uP
ACKNOWLEDGED BEFORE ME THIS _DAY OFSL3At. 20 l .3 . BY -Sate -A 1r1I iu.
WHO IS PERSONALLY KNOWN TO MEJL_ OR WHO HAS PRODUCED
GERI L. CALHOUN
AS IDENTIFICATION. * ;�s Notary Public - State of Florida
(l�n p u� I L �A My Cyf Expires Oct 6, 2015
( 0 ` lLQ ��FOFF�pO`,- CD mission # EE 105900
I NATURE OFNOTARY TYPE OR PRINT NAME OF NOTARY �,,,ttBonded Through National Notary Assn.
CONUMSSIONNUMBER lj LQSif
NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR
LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
EXEMPT: A/C -HEAT REPLACEMENT wrm CONTRACT UNDER $7500.00
Revised 04/2&2010
I
Job: 5352
rigl Right JO Mobile Report Bate: dames Williams
Entire House
All American Air & Electric
3g t °° :�` 4 3$,
3
Project ltnforrnlatloin
For: Harold dillon
5611 sun berry circle, Ft pierce, FL 34951
Phone: 772-467-9620
P'idn Contl=tic
Location:
Indoor:
Heating
70
Cooling
75
Vero Beach Municipal AP, FL, US
Indoor temperature (TF)
27
16
Elevation: 23 ft
Latitude: 28°N
Design TD (F)
Relative humidity (%)
30
50
Outdoor: Heating
Cooling
Moisture difference (gr/lb)
-0.3
59.2
Dry bulb (°F) 43
Daily range (°F) -
91
16 (I_
Infiltration:
) Method
Simplified
Wet bulb (T) -
78
Construction quality
Average
Wind speed (mph) 15.0
7.5
Fireplaces
0
!s`a r.
, ro b' A,.,s,;J ' _tee b ° �- ,,,t sa_ s. er, „ .-
. B'.'f"�,
Component
Btuh/ft2
Btuh
% of load
Walls
3.8
5839
18.0
Glazing
34.0
8691
26.7
Doors
14.5
304
0.9
Ceilings
0.9
1286
4.0
Floors
2.1
3136
9.6
Infiltration
1.7
2982
9.2
Ducts
10280
31.6
Piping
0
0
Humidification
0
0
Ventilation
0
0
Adjustments
0
Total
32518
100.0
omponent
tuh/ft Btuh % of load
Walls 2.6 3911 11.7
Glazing 50.2 12827 38.5
Doors 15.7 331 1.0
Ceilings 0.9 1327 4.0
Floors 1.0 1480 4.4
Infiltration 0.5 887 2.7
Ducts 9256 27.7
Ventilation 0 0
Internal gains 3340 10.0
Blower 0 0
Adjustments 0
Total 1 1 33360 100.0
B
Latent Cooling Load = 6047 Btuh
Overall U-value = 0.150 Btuh/ft? °F
Data entries checked.
wrtght Oft' Right-Suite(D Universal 2012 12.1.07 Right J® Mobile
\wstmp\9cd7e481-dbbc-4da9-8cb2-98dc71740418.rup Calc = MJB Front Door faces: N
daft
GadT
cdlirgs
t
2013-May-28 13:18:11
Page 1
la QL I ArnS
B
Latent Cooling Load = 6047 Btuh
Overall U-value = 0.150 Btuh/ft? °F
Data entries checked.
wrtght Oft' Right-Suite(D Universal 2012 12.1.07 Right J® Mobile
\wstmp\9cd7e481-dbbc-4da9-8cb2-98dc71740418.rup Calc = MJB Front Door faces: N
daft
GadT
cdlirgs
t
2013-May-28 13:18:11
Page 1
la QL I ArnS
Job: 5352
}r FF� Right J® Mobile Report Date: 5128/2013
- - gE L�is 1 f. Entire House By: James Williams
All American Air & Electric
575 NW Mercintile Place, port St Lucie, FL 3986 Phone: 772-878-5143 Fa)c 772-878-5144 Email: Jw260aaaeinc@yahoo.comLicense: Cac057965
Project• •
For. Harold dillon
5611. sun berry circle, Ft pierce, FL 34951
Phone: 772-467-9620
pesiq,n.�Conditions
Location:
Indoor:
Heating
Cooling
Vero Beach Municipal AP, FL, US
Indoor temperature (°F)
70
27
75
16
Elevation: 23 ft
Latitude: 28°N
Design TD (°F)
Relative humidity (%)
30
50
Outdoor: Heating
Cooling
Moisture difference (gr/lb)
-0.3
59.2
Dry bulb (°F) 43
91
Infiltration:
Daily range (°F) -
16 ( L
) Method
Simplified
Wetbulb ° -
78
Construction quality
Average
Wind speed (mph) 15.0
7.5
Fireplaces
0
He'atin: ;
Component
Btuh/ftz
Btuh
% of load
Walls
3.8
5839
18.0
Glazing
34.0
8691
26.7
Doors
14.5
304
0.9
Ceilings
0.9
1286
4.0
Floors
2.1
3136
9.6
Infiltration
1.7
2982
9.2
Ducts
10280
31.6
Piping
0
0
Humidification
0
0
Ventilation
0
0
Adjustments
0
Total
32518
100.0
Coaling
Component
Btuh/fe
Btuh
% of load
Walls
2.6
3911
11.7
Glazing
50.2
12827
38.5
Doors
15.7
331
1.0
Ceilings
0.9
1327
4.0
Floors
1.0
1480
4.4
Infiltration
0.5
887
2.7
Ducts
9256
27.7
Ventilation
0
0
Internal gains
3340
10.0
Blower
0
0
Adjustments
0
Total
33360
100.0
Latent Cooling Load = 6047 Btuh
Overall U-value = 0.150 Btuh/ft=-°F
Data entries checked.
aaft
aadng
Lauri
lrfiltratai
2013-May-2813:18:11
WIr19 hltSOft* Right -Suite® Universal 2012 12.1.07 Right JO Mobile Page 1
...lwstmpt9od7e481-dbbc-4da9-8cb2-98dc71740418.rup Calc = MJ8 Front Door faces: N
Project Summary Job: 5352
1i!Iit`thlkStJrf 1 rY Date: 512812013
Entire House By: James Williams
All American Air & Electric
575 NW Mercintile Place, port St Lucie, FL 3986 Phone: 772-878-5143 Fax 772-878-5144 Email: Jw260aaaeinc@yahoo.com License: Cac057965
For. Harold dillon
5011 sun berry circle, Ft pierce, FL 34951
Phone: 772-467-9620
Notes:
Design
:
Weather. Vero Beach Municipal AP, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db 43 OF
Outside db
91 OF
Inside db 70 OF
Inside db
75 OF
Design TD 27 OF
Design TD
16 OF
Daily range
L
Relative humidity
50 %
Moisture difference
59 gr/lb
Heating Summary
Sensible Cooling Equipment Load Sizing
Structure 22238 Btuh
Structure
24103 Btuh
Ducts 10280 Btuh
Ducts
9256 Btuh
Central vent (0 cfm) 0 Btuh
Central vent (0 cfm)
0 Btuh
Humidification 0 Btuh
Blower
0 Btuh
Piping 0 Btuh
Equipment load 32518 Btuh
Use manufacturer's data
y
Rate/swing multiplier
1.00
Infiltration
Equipment sensible load
33360 Btuh
Method Simplified
Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0
Structure
3881 Btuh
Ducts
2167 Btuh
Heating Cooling
Central vent (0 cfm)
0 Btuh
Area (ft� 1500 1500
Equipment latent load
6047 Btuh
Volume (ft') 13500 13500
Air changes/hour 0.45 0.23
Equipment total load
39407 Btuh
Equiv. AVF (cfm) 101 52
Req. total capacity at 0.72 SHR
. to
Heating Equipment Summary
Cooling Equipment Summary
Make Goodman
Make Goodman
Trade Amana distinctions
Trade Amana distinctions
Model Avptc426014
Cond Gsx130421
AHRI ref 4431268
Coil Capf4961d
AHRI ref 4431268
Efficiency 0 AFUE
Efficiency
Heating input 0 MBtuh
Sensible cooling
41400 Btuh
Heating output 0 Btuh
Latent cooling
16100 Btuh
Temperature rise 0 OF
Total cooling
57500 Btuh
Actual air flow 1525 cfm
Actual air flow
1525 cfm
Air flow factor 0.047 cfm/Btuh
Air flow factor
0.046 cfm/Btuh
Static pressure 0 in H2O
Static pressure
0 in H2O
Space thermostat
Load sensible heat ratio
0.85
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
t hiQ Right -Suite® Universal 2012 12.1.07 Right J® Mobile
2013-May-2813:18:11
Page 1
lwstmp19cd7e481-dbbc-4da9-8cb2-98dc71740418.rup Cale = MJ8 Front Doorfaces: N
AL Job: 5362
7FV wrightsoft, RighW@ Worksheet Entire House Date: 512812013
All American Air & Electric BY: James Williams
675 NW Mercintifle Place, port St Lucie, FL 3986 Phone: 772-878-5143 Fax: 772-878-5144 Email: Jw260aaaeinc@yahoo.com License: Cac057965
I
Room name
Entire House
First Floor
2
Exposed wall
200.0
ft
200.0
ft
3
Room height
9.0 ft
d
9.0 ft
heat/cool
4
Room dimensions
1.0
x
1500.0 ft
5
Room area
1500.0 ft'
1500.0 ft'
Ty
I
Construction
I I
U--'ue I
I
Or
HTIVI
Area (ft2)
I
Load
Area (ft')
Load
number
BtuhffV-'F)
tuhift
OF perimeter
(ft) I
(Btuh)
I
or perimeter
(ft) I
(BtUh)
Heat
Cool
Gross
WP/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
1
3.83
257:
640
485
1857
1244
540
..
1857
'4244
Zc torn
-_:��34-04
26.91.
6
0
204
161
::6
.... . ...
.485
:0
204
�:161,
1P clorn
.1-270
-:-:--'34
2,v,
13
0
454
359
0
454:
369
14-ci din -
1
3404!
26.41
.15
511
4D4
15
0 -
511 -
404-,
01540.
.:z:n--.
14A7
715.74
'21
21
304
:;il
--'.21
304
331
1 3A-4ocs
0.143
3.83
2.57
360
262
1004
673
360
262
1004
673
,A-cl om
1.270
a
34.04
65.60
50
0
1702
3280
50
0
1702
3280
1A-cl,om.d
1.270
e
34.04
65.60
48
0
1634
3149
48
0
1634
314
.13 ocs
0.143
s
3M:
:2657
540
472
1809
1212
-W
472
1809.
4212
IA-cl
.04
2724
20._
18
:-:z'681
545
20
18
681
545
AreldrW&;
`1.2 7
s
34,4 ...
-27 .53
.1634
1634.
:A3221
t13A-4ocs
0.143
w
3.83
2.57
360
305
1169
783
360
305
1 169
783
-G
1A-clom
1.270
w
34.04
65. 0
55
0
1872
3608
1872
3608
C
AOE73011-
.. ....
.......
O,w:
o.a8
1500
1500
-1327,
500
1500
. . ....
1286:
:1327.
F
2013-11t
.7-: A .....
.
0.078
nz.
2.09
0.99
k"
1500
1500
3136
1480
1500
1500
3136
14.80
....
... ...... . .
.....
....... ... .
:4.
1 61
q) AED excursion an
01
1
0
Envelope losstgain
1
192561
198761
1
1
192561
19876
12
a) Infiltration
2982
887
2982
887
b) Room ventilation
0
0
0
0
13
Internal gains:
Occupants @
230
3
690
3
690
Appliances/other
2650
2650
Subtotal (lines 6 to 13)
22238
24103.
22238
24103
Less external load
0
0
a
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
22238
24103
22238
24103
15
Duct loads
46%
38%
10280
9256
46%
38%
10280
9256
Total room load
325181
333601
325181
333601
Air required (chn)
1
1
15251
15251
15251
15291
Calculations approved_ by ACCA to meet all reauirements of Manual J 8th Ed.
, -FI4- Right -Suite@ Universal 2012 12.1.07 Right JS Mobile Page
13:18:11
14��M %Wstmp\gccr7e481-dbbc-4dag-8cb2-98dc7l740418.rup Cale = MJ8 Front Door faces: N Page 1
Component Constructions Job: 5352
��IK��i�'� p Date: 512812013
Entire House By: James Williams
All American Air & Electric
575 NW Mercintile Place, port St Lucie. FL 3986 Phone: 772-878-5143 Fax 772-878-5144 Email: Jw260aaaeinc@yahoo.com License: Cac057965
nZiolippt,intormation,-
For Harold dillon
5611 sun berry circle, Ft pierce, FL 34951
Phone: 772-467-9620
®- •
e e o
Location:
Indoor:
Heating
Cooling
Vero Beach Municipal AP, FL, US
Indoor temperature ("F)
70
75
Elevation: 23 ft
Design TD (T)
27
16
Latitude: 28°N
Relative humidity (%)
30
50
Outdoor: Heating
Cooling
Moisture difference (gr/lb)
-0.3
59.2
Dry bulb (T) 43
91
Infiltration:
Dailyrange (T) -
16 (L
) Method
Simplified
Wet bulb (T) -
78
Construction quality
Average
Wind speed (mph) 15.0
7.5
Fireplaces
0
Construction descriptions
or
Area
U-value
Insul R
Htg HTM
Loss
Clg HTM
Gain
ft'
Btuhflt'--°F
82-'F/Bluh
BlON
Bluh
Btuh/ft'
Btuh
Walls
13A4ocs: Blk wall, stucco ext, r-4 ext bd ins, 6" thk, 1 /2" gypsum
n
485
0.143
4.0
3.83
1857
2.57
1244
board int fish
a
262
0.143
4.0
3.83
1004
2.57
673
s
472
0.143
4.0
3.83
1809
2.57
1212
w
305
0.143
4.0
3.83
1169
2.57
783
all
1524
0.143
4.0
3.83
5839
2.57
3911
Partitions
(none)
Windows
IA-clom: 1 glazing, clr giz, mtl no brk frm mat, 1/8" thk; 50% blinds
n
45°, light; 50% outdoor insect screen; 1 ft overhang (3 ft w indow ht,
1 ft sep.)
1A-clom: 1 glazing, clr giz, mtl no brk frm mat, 1/8" thk; 50% blinds
n
45°, light; 50% outdoor insectscreen
1A-clom: 1 glazing, clr glz, mtl no brk frm mat, 1/8" thk; 50% blinds
n
45°, light; 50% outdoor insect screen; 1 ft overhang (5 ft w indow ht,
e
1 ft sep.)
s
w
all
IA-clomd: 1 glazing cir glz mtl no brk fret mat 1/8" thk- 50% blinds
e
6
1.270
0
34.0
204
26.9
161
13
1.270
0
34.0
454
26.9
359
15
1.270
0
34.0
511
26.9
404
50
1.270
0
34.0
1702
65.6
3280
20
1.270
0
34.0
681
27.2
545
55
1.270
0
34.0
1872
65.6
3608
140
1.270
0
34.0
4765
56.0
7837
48
1.270
0
34.0
1634
65.6
3149
45°, light; 50% outdoor insect sc reen; 1 ft overhang (8ftw indow ht,
1 ft sep.)
1A-clomd: 1 glazing, clr giz, mtl no brk frm mat, 1/8" thk; 50% blinds s 48 1.270 0 34.0 1634 27.5 1322
45°, light; 50% outdoor inse ct sc reen; 3ftoverhang (8ftw indow ht,
10 ft sep.)
Doors
11GO: Door, wd pnl type n 21 0.540 0 14.5 304 15.7 331
Ceilings
16E-30ti: Attic ceiling, tile, slate, concrete roof mat, r-30 cell ins, 1/2" 1500 0.032 30.0 0.86 1286 0.88 1327
gypsum board int fish
2013-May-28 13:18:12
Wrlg)htsOft' Right -Suite® Universal 2012 12.1.07 Right J® Mobile Page 1
J+...\wstmp\9cd7e481-dbbc-4da9-Bcb2-98dc71740418.rup Calc = MJ8 Front Doorfaces: N
I\
Floors
20P-11t: Flr floor, wd fir, 1" thkns, the flr fish, r-11 ext ins, amb ovr
I j
1500 0.078 11.0 2.09 3136 0.99 1480
2013-May-2813:18:12
,+ W rightSOft' Rig ht-Suite® U niversal 2012 12.1.07 Right J® Mobile Page 2
S ...\wstmp19cd7e481-dbbc-4da9-Bcb2-98dc71740418.rup Calc = MJ8 Front Doorfaces: N
i
�r AED Assessment Job: 5352
vt�►rii htso •, Date: 5/28/2013
Entire House By: James Williams
All American Air & Electric
575 NW Mercintile Place, port St Lucie, Ft. 3986 Phone: 772-878-5143 Fax: 772-878-5144 Email: Jw260aa8einc@yahoo.com License: Cac057965
Pro.j.dict Information
For: Harold dillon
5611 sun berry circle, Ft pierce, FL 34951
Phone: 772-467-9620
DeSign,,Cpnditions
Location:
Indoor:
Heating
Cooling
Vero Beach Municipal AP, FL, US
Indoor temperature (T)
70
75
Elevation: 23 It
Design TD (OF)
27
16
Latitude: 28 ON
Relative humidity (%)
30
50
Outdoor: Heating
Cooling
Moisture difference (gr/lb)
-0.3
59.2
Drybulb (OF) 43
91
Infiltration:
Daily range (`F) -
16 ( L
)
Wetbulb('F) -
78
Wind speed (mph) 15.0
7.5
ior
Adeq
po,,e",kty
Hourly Glazing Load
Hour of Day
el FbAiy , Average AHNn it
Maximum hourly glazing load exceeds average by 10.8%.
House has adequate exposure diversity (AED), based on AED limit of 30%.
AED excursion: 0 Btuh
2013-May-28 13:18:12
w rights0f . Right -Suite® Universal 2012 12.1.07 Right JO Mobile Page 1
{ s...\wstmpX9cd7e481-dbbe-4dag-8cb2-98dc71740418.rup Calc = MJB Front Door faces: N
First Flom
Job #: 5352
All American Air & Electric
Scale: 1 : 100
Performed by James Williams for:
Page 1
Harold dillon
575 NW Mercintile Place
Right -Suite® Universa12012
5611 sun berry circle
port St Lucie, FL 3986
12.1.07 Right J® Mobile
Ft pierce, FL 34951
Phone: 772-878-5143 Fax: 772-878-5144
2013-May-28 13:18:13
Phone: 772467-9620
...-dbbc4da9-8cb2-98dc71740418....
AHRI Certified Reference Number: 4431268 Date: 6/3/2013
Product: Split System: Air -Cooled Condensing Unit, Coil with Blower
Outdoor Unit Model Number: SSX140421C*
Indoor Unit Model Number: AVPTC426014A*
Manufacturer: GOODMAN MANUFACTURING CO., LP.
Trade/Brand name: GOODMAN, JANITROL, AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR
CONDITIONING AND HEATING, ENERGI AIR
Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP.
Rated as follows in accordance with AHRI Standard 2101240-2008 for Unitary Air -Conditioning and Air -Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third
party testing:
Cooling Capacity (Btuh):
40000
EER Rating (Cooling):
12.50
SEER Rating_ (Cooling):
15.00
• Ratings followed by an asterisk (•) indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate
DISCLAIMER
AHRI does not endorse the product(s) fisted on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for,
the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out ofthe use or performance ofthe product(s), or the
unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes.
The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any
form or manner or by any means, except for the user's individual, personal and confidential reference.
CERTIFICATE VERIFICATION
The Information for the model cited an this certificate can be verged at www.ahridirectory.org, Air -Conditioning, Heating,
click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on ON ®® and Refrigeration Institute
which the certificate was Issued, which Is listed above, and the Certificate No., which Is fisted below.
02013 Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130147405083027164