Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSi Date: Fee Duel Receipt# rY%.l TPermit # _ /f & Planning & Development Services Building & Code Regulations Division 2300 Virginia Ave. Fort Pierce, FL 34982 (772)462-1553 SCANNeD SY St. Lucie County SPECIALTY PERMIT APPLICATION ❑ Electrical ❑ Plumbing Q"HVAC ❑ Fence ❑ Shed ❑ Demolition ❑ Gas ❑ Siding See page 2 for instructions and additional paperwork required for specialty permits 1. Location/Site Address: t45LQ 1,n L c w C�i -&e_ 2. Parcel ID Number: ( 31 a L4 c)(X) - 1 Office Use Only Section Township Range Map Page Zoning Land Use Initials 3. Complete Description of Project or Work: '3 I -A T r\ A l � t d 1, 4. Owners Information 1 5. Contractors Information Name: LAC6k A h, [ [ on 55 FL Reg/Cert #: i� , �l1.S-7 q [n Address: 5(2 � ( � isy\ ke crw l/+ ud t, _ County Cert#: .2n D g F City: i ► i-bt- State: Business NName:. M I Aiyer1 c,.,, Aw -4 clr,,M e- Zip: 54C c51 Phone: Zd Phone: ` `Sl �i. Fag: a 7 8'51y q r 6. Value of Construction: $ 9 969 owNEws AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in compliance with all applicable laws regulating construction and zoning. PRINT OWNER OR CON CTOR NAME SIGN WNER Ok CONTRACTOR STATE OF FLORIDA, COUNTY OF �� r Lk uP ACKNOWLEDGED BEFORE ME THIS _DAY OFSL3At. 20 l .3 . BY -Sate -A 1r1I iu. WHO IS PERSONALLY KNOWN TO MEJL_ OR WHO HAS PRODUCED GERI L. CALHOUN AS IDENTIFICATION. * ;�s Notary Public - State of Florida (l�n p u� I L �A My Cyf Expires Oct 6, 2015 ( 0 ` lLQ ��FOFF�pO`,- CD mission # EE 105900 I NATURE OFNOTARY TYPE OR PRINT NAME OF NOTARY �,,,ttBonded Through National Notary Assn. CONUMSSIONNUMBER lj LQSif NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. EXEMPT: A/C -HEAT REPLACEMENT wrm CONTRACT UNDER $7500.00 Revised 04/2&2010 I Job: 5352 rigl Right JO Mobile Report Bate: dames Williams Entire House All American Air & Electric 3g t °° :�` 4 3$, 3 Project ltnforrnlatloin For: Harold dillon 5611 sun berry circle, Ft pierce, FL 34951 Phone: 772-467-9620 P'idn Contl=tic Location: Indoor: Heating 70 Cooling 75 Vero Beach Municipal AP, FL, US Indoor temperature (TF) 27 16 Elevation: 23 ft Latitude: 28°N Design TD (F) Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) -0.3 59.2 Dry bulb (°F) 43 Daily range (°F) - 91 16 (I_ Infiltration: ) Method Simplified Wet bulb (T) - 78 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 !s`a r. , ro b' A,.,s,;J ' _tee b ° �- ,,,t sa_ s. er, „ .- . B'.'f"�, Component Btuh/ft2 Btuh % of load Walls 3.8 5839 18.0 Glazing 34.0 8691 26.7 Doors 14.5 304 0.9 Ceilings 0.9 1286 4.0 Floors 2.1 3136 9.6 Infiltration 1.7 2982 9.2 Ducts 10280 31.6 Piping 0 0 Humidification 0 0 Ventilation 0 0 Adjustments 0 Total 32518 100.0 omponent tuh/ft Btuh % of load Walls 2.6 3911 11.7 Glazing 50.2 12827 38.5 Doors 15.7 331 1.0 Ceilings 0.9 1327 4.0 Floors 1.0 1480 4.4 Infiltration 0.5 887 2.7 Ducts 9256 27.7 Ventilation 0 0 Internal gains 3340 10.0 Blower 0 0 Adjustments 0 Total 1 1 33360 100.0 B Latent Cooling Load = 6047 Btuh Overall U-value = 0.150 Btuh/ft? °F Data entries checked. wrtght Oft' Right-Suite(D Universal 2012 12.1.07 Right J® Mobile \wstmp\9cd7e481-dbbc-4da9-8cb2-98dc71740418.rup Calc = MJB Front Door faces: N daft GadT cdlirgs t 2013-May-28 13:18:11 Page 1 la QL I ArnS B Latent Cooling Load = 6047 Btuh Overall U-value = 0.150 Btuh/ft? °F Data entries checked. wrtght Oft' Right-Suite(D Universal 2012 12.1.07 Right J® Mobile \wstmp\9cd7e481-dbbc-4da9-8cb2-98dc71740418.rup Calc = MJB Front Door faces: N daft GadT cdlirgs t 2013-May-28 13:18:11 Page 1 la QL I ArnS Job: 5352 }r FF� Right J® Mobile Report Date: 5128/2013 - - gE L�is 1 f. Entire House By: James Williams All American Air & Electric 575 NW Mercintile Place, port St Lucie, FL 3986 Phone: 772-878-5143 Fa)c 772-878-5144 Email: Jw260aaaeinc@yahoo.comLicense: Cac057965 Project• • For. Harold dillon 5611. sun berry circle, Ft pierce, FL 34951 Phone: 772-467-9620 pesiq,n.�Conditions Location: Indoor: Heating Cooling Vero Beach Municipal AP, FL, US Indoor temperature (°F) 70 27 75 16 Elevation: 23 ft Latitude: 28°N Design TD (°F) Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) -0.3 59.2 Dry bulb (°F) 43 91 Infiltration: Daily range (°F) - 16 ( L ) Method Simplified Wetbulb ° - 78 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 He'atin: ; Component Btuh/ftz Btuh % of load Walls 3.8 5839 18.0 Glazing 34.0 8691 26.7 Doors 14.5 304 0.9 Ceilings 0.9 1286 4.0 Floors 2.1 3136 9.6 Infiltration 1.7 2982 9.2 Ducts 10280 31.6 Piping 0 0 Humidification 0 0 Ventilation 0 0 Adjustments 0 Total 32518 100.0 Coaling Component Btuh/fe Btuh % of load Walls 2.6 3911 11.7 Glazing 50.2 12827 38.5 Doors 15.7 331 1.0 Ceilings 0.9 1327 4.0 Floors 1.0 1480 4.4 Infiltration 0.5 887 2.7 Ducts 9256 27.7 Ventilation 0 0 Internal gains 3340 10.0 Blower 0 0 Adjustments 0 Total 33360 100.0 Latent Cooling Load = 6047 Btuh Overall U-value = 0.150 Btuh/ft=-°F Data entries checked. aaft aadng Lauri lrfiltratai 2013-May-2813:18:11 WIr19 hltSOft* Right -Suite® Universal 2012 12.1.07 Right JO Mobile Page 1 ...lwstmpt9od7e481-dbbc-4da9-8cb2-98dc71740418.rup Calc = MJ8 Front Door faces: N Project Summary Job: 5352 1i!Iit`thlkStJrf 1 rY Date: 512812013 Entire House By: James Williams All American Air & Electric 575 NW Mercintile Place, port St Lucie, FL 3986 Phone: 772-878-5143 Fax 772-878-5144 Email: Jw260aaaeinc@yahoo.com License: Cac057965 For. Harold dillon 5011 sun berry circle, Ft pierce, FL 34951 Phone: 772-467-9620 Notes: Design : Weather. Vero Beach Municipal AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 43 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 27 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 59 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 22238 Btuh Structure 24103 Btuh Ducts 10280 Btuh Ducts 9256 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 32518 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 33360 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3881 Btuh Ducts 2167 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft� 1500 1500 Equipment latent load 6047 Btuh Volume (ft') 13500 13500 Air changes/hour 0.45 0.23 Equipment total load 39407 Btuh Equiv. AVF (cfm) 101 52 Req. total capacity at 0.72 SHR . to Heating Equipment Summary Cooling Equipment Summary Make Goodman Make Goodman Trade Amana distinctions Trade Amana distinctions Model Avptc426014 Cond Gsx130421 AHRI ref 4431268 Coil Capf4961d AHRI ref 4431268 Efficiency 0 AFUE Efficiency Heating input 0 MBtuh Sensible cooling 41400 Btuh Heating output 0 Btuh Latent cooling 16100 Btuh Temperature rise 0 OF Total cooling 57500 Btuh Actual air flow 1525 cfm Actual air flow 1525 cfm Air flow factor 0.047 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.85 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. t hiQ Right -Suite® Universal 2012 12.1.07 Right J® Mobile 2013-May-2813:18:11 Page 1 lwstmp19cd7e481-dbbc-4da9-8cb2-98dc71740418.rup Cale = MJ8 Front Doorfaces: N AL Job: 5362 7FV wrightsoft, RighW@ Worksheet Entire House Date: 512812013 All American Air & Electric BY: James Williams 675 NW Mercintifle Place, port St Lucie, FL 3986 Phone: 772-878-5143 Fax: 772-878-5144 Email: Jw260aaaeinc@yahoo.com License: Cac057965 I Room name Entire House First Floor 2 Exposed wall 200.0 ft 200.0 ft 3 Room height 9.0 ft d 9.0 ft heat/cool 4 Room dimensions 1.0 x 1500.0 ft 5 Room area 1500.0 ft' 1500.0 ft' Ty I Construction I I U--'ue I I Or HTIVI Area (ft2) I Load Area (ft') Load number BtuhffV-'F) tuhift OF perimeter (ft) I (Btuh) I or perimeter (ft) I (BtUh) Heat Cool Gross WP/S Heat Cool Gross N/P/S Heat Cool 6 1 3.83 257: 640 485 1857 1244 540 .. 1857 '4244 Zc torn -_:��34-04 26.91. 6 0 204 161 ::6 .... . ... .485 :0 204 �:161, 1P clorn .1-270 -:-:--'34 2,v, 13 0 454 359 0 454: 369 14-ci din - 1 3404! 26.41 .15 511 4D4 15 0 - 511 - 404-, 01540. .:z:n--. 14A7 715.74 '21 21 304 :;il --'.21 304 331 1 3A-4ocs 0.143 3.83 2.57 360 262 1004 673 360 262 1004 673 ,A-cl om 1.270 a 34.04 65.60 50 0 1702 3280 50 0 1702 3280 1A-cl,om.d 1.270 e 34.04 65.60 48 0 1634 3149 48 0 1634 314 .13 ocs 0.143 s 3M: :2657 540 472 1809 1212 -W 472 1809. 4212 IA-cl .04 2724 20._ 18 :-:z'681 545 20 18 681 545 AreldrW&; `1.2 7 s 34,4 ... -27 .53 .1634 1634. :A3221 t13A-4ocs 0.143 w 3.83 2.57 360 305 1169 783 360 305 1 169 783 -G 1A-clom 1.270 w 34.04 65. 0 55 0 1872 3608 1872 3608 C AOE73011- .. .... ....... O,w: o.a8 1500 1500 -1327, 500 1500 . . .... 1286: :1327. F 2013-11t .7-: A ..... . 0.078 nz. 2.09 0.99 k" 1500 1500 3136 1480 1500 1500 3136 14.80 .... ... ...... . . ..... ....... ... . :4. 1 61 q) AED excursion an 01 1 0 Envelope losstgain 1 192561 198761 1 1 192561 19876 12 a) Infiltration 2982 887 2982 887 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 3 690 3 690 Appliances/other 2650 2650 Subtotal (lines 6 to 13) 22238 24103. 22238 24103 Less external load 0 0 a 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 22238 24103 22238 24103 15 Duct loads 46% 38% 10280 9256 46% 38% 10280 9256 Total room load 325181 333601 325181 333601 Air required (chn) 1 1 15251 15251 15251 15291 Calculations approved_ by ACCA to meet all reauirements of Manual J 8th Ed. , -FI4- Right -Suite@ Universal 2012 12.1.07 Right JS Mobile Page 13:18:11 14��M %Wstmp\gccr7e481-dbbc-4dag-8cb2-98dc7l740418.rup Cale = MJ8 Front Door faces: N Page 1 Component Constructions Job: 5352 ��IK��i�'� p Date: 512812013 Entire House By: James Williams All American Air & Electric 575 NW Mercintile Place, port St Lucie. FL 3986 Phone: 772-878-5143 Fax 772-878-5144 Email: Jw260aaaeinc@yahoo.com License: Cac057965 nZiolippt,intormation,- For Harold dillon 5611 sun berry circle, Ft pierce, FL 34951 Phone: 772-467-9620 ®- • e e o Location: Indoor: Heating Cooling Vero Beach Municipal AP, FL, US Indoor temperature ("F) 70 75 Elevation: 23 ft Design TD (T) 27 16 Latitude: 28°N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) -0.3 59.2 Dry bulb (T) 43 91 Infiltration: Dailyrange (T) - 16 (L ) Method Simplified Wet bulb (T) - 78 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' Btuhflt'--°F 82-'F/Bluh BlON Bluh Btuh/ft' Btuh Walls 13A4ocs: Blk wall, stucco ext, r-4 ext bd ins, 6" thk, 1 /2" gypsum n 485 0.143 4.0 3.83 1857 2.57 1244 board int fish a 262 0.143 4.0 3.83 1004 2.57 673 s 472 0.143 4.0 3.83 1809 2.57 1212 w 305 0.143 4.0 3.83 1169 2.57 783 all 1524 0.143 4.0 3.83 5839 2.57 3911 Partitions (none) Windows IA-clom: 1 glazing, clr giz, mtl no brk frm mat, 1/8" thk; 50% blinds n 45°, light; 50% outdoor insect screen; 1 ft overhang (3 ft w indow ht, 1 ft sep.) 1A-clom: 1 glazing, clr giz, mtl no brk frm mat, 1/8" thk; 50% blinds n 45°, light; 50% outdoor insectscreen 1A-clom: 1 glazing, clr glz, mtl no brk frm mat, 1/8" thk; 50% blinds n 45°, light; 50% outdoor insect screen; 1 ft overhang (5 ft w indow ht, e 1 ft sep.) s w all IA-clomd: 1 glazing cir glz mtl no brk fret mat 1/8" thk- 50% blinds e 6 1.270 0 34.0 204 26.9 161 13 1.270 0 34.0 454 26.9 359 15 1.270 0 34.0 511 26.9 404 50 1.270 0 34.0 1702 65.6 3280 20 1.270 0 34.0 681 27.2 545 55 1.270 0 34.0 1872 65.6 3608 140 1.270 0 34.0 4765 56.0 7837 48 1.270 0 34.0 1634 65.6 3149 45°, light; 50% outdoor insect sc reen; 1 ft overhang (8ftw indow ht, 1 ft sep.) 1A-clomd: 1 glazing, clr giz, mtl no brk frm mat, 1/8" thk; 50% blinds s 48 1.270 0 34.0 1634 27.5 1322 45°, light; 50% outdoor inse ct sc reen; 3ftoverhang (8ftw indow ht, 10 ft sep.) Doors 11GO: Door, wd pnl type n 21 0.540 0 14.5 304 15.7 331 Ceilings 16E-30ti: Attic ceiling, tile, slate, concrete roof mat, r-30 cell ins, 1/2" 1500 0.032 30.0 0.86 1286 0.88 1327 gypsum board int fish 2013-May-28 13:18:12 Wrlg)htsOft' Right -Suite® Universal 2012 12.1.07 Right J® Mobile Page 1 J+...\wstmp\9cd7e481-dbbc-4da9-Bcb2-98dc71740418.rup Calc = MJ8 Front Doorfaces: N I\ Floors 20P-11t: Flr floor, wd fir, 1" thkns, the flr fish, r-11 ext ins, amb ovr I j 1500 0.078 11.0 2.09 3136 0.99 1480 2013-May-2813:18:12 ,+ W rightSOft' Rig ht-Suite® U niversal 2012 12.1.07 Right J® Mobile Page 2 S ...\wstmp19cd7e481-dbbc-4da9-Bcb2-98dc71740418.rup Calc = MJ8 Front Doorfaces: N i �r AED Assessment Job: 5352 vt�►rii htso •, Date: 5/28/2013 Entire House By: James Williams All American Air & Electric 575 NW Mercintile Place, port St Lucie, Ft. 3986 Phone: 772-878-5143 Fax: 772-878-5144 Email: Jw260aa8einc@yahoo.com License: Cac057965 Pro.j.dict Information For: Harold dillon 5611 sun berry circle, Ft pierce, FL 34951 Phone: 772-467-9620 DeSign,,Cpnditions Location: Indoor: Heating Cooling Vero Beach Municipal AP, FL, US Indoor temperature (T) 70 75 Elevation: 23 It Design TD (OF) 27 16 Latitude: 28 ON Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) -0.3 59.2 Drybulb (OF) 43 91 Infiltration: Daily range (`F) - 16 ( L ) Wetbulb('F) - 78 Wind speed (mph) 15.0 7.5 ior Adeq po,,e",kty Hourly Glazing Load Hour of Day el FbAiy , Average AHNn it Maximum hourly glazing load exceeds average by 10.8%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh 2013-May-28 13:18:12 w rights0f . Right -Suite® Universal 2012 12.1.07 Right JO Mobile Page 1 { s...\wstmpX9cd7e481-dbbe-4dag-8cb2-98dc71740418.rup Calc = MJB Front Door faces: N First Flom Job #: 5352 All American Air & Electric Scale: 1 : 100 Performed by James Williams for: Page 1 Harold dillon 575 NW Mercintile Place Right -Suite® Universa12012 5611 sun berry circle port St Lucie, FL 3986 12.1.07 Right J® Mobile Ft pierce, FL 34951 Phone: 772-878-5143 Fax: 772-878-5144 2013-May-28 13:18:13 Phone: 772467-9620 ...-dbbc4da9-8cb2-98dc71740418.... AHRI Certified Reference Number: 4431268 Date: 6/3/2013 Product: Split System: Air -Cooled Condensing Unit, Coil with Blower Outdoor Unit Model Number: SSX140421C* Indoor Unit Model Number: AVPTC426014A* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade/Brand name: GOODMAN, JANITROL, AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 2101240-2008 for Unitary Air -Conditioning and Air -Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): 40000 EER Rating (Cooling): 12.50 SEER Rating_ (Cooling): 15.00 • Ratings followed by an asterisk (•) indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate DISCLAIMER AHRI does not endorse the product(s) fisted on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out ofthe use or performance ofthe product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION The Information for the model cited an this certificate can be verged at www.ahridirectory.org, Air -Conditioning, Heating, click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on ON ®® and Refrigeration Institute which the certificate was Issued, which Is listed above, and the Certificate No., which Is fisted below. 02013 Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130147405083027164