Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSPlanning & Development Services Building & Code Regulations Division 2300 Virginia Ave. Fort Pierce, FL 34982 (772)462-1553 St. SPECIALTY PERMIT APPLICATION ❑ Electrical ❑ Plumbing AC ❑ Fence ❑ Shed ❑ Demolition ❑ Gas ❑ Siding Seepage 2 for instructions and additional paperwork required for specialty permits 1. Location/Site Address: Sa% I� I`-;Pj b-4h �� 2. Parcel ID Number: 3 u �6 — r-D I 0 6 --?--co — 0 O d — CUC/e County Office Use Only Section Township Range Map Page Z4ftning Land Use In' as 3. Complete Description of Project or W 4. Owners Information �I , Contractors Information Name: l�� �` 'I ��\ Z C� �eg/Cert #: Address: 6u 1 County Cert#: City: fA LuLc, Coh State:Business Name: c ac -C\ \-A.6�g a� 6 <CccU (-2, Ny�-ui LC� Zip: �L,C1S =' Phone: /' ?��46�1. 5 Phone. Sri CI��-�100 Fax: 6. Value of Construction: $ ��1 T �� OWNER'S AFFIDAVIT: I certify that all of the information con ' `e i this application is correct and that all work will be compliance with all applicable laws reg ti onstruction aZnd zoning . rarr' PRINT OWNER OR CONTRACTOR NASIG-TURE-OF WNER OR�CONTRACTOR STATE OF FLORIDA, COUNTY OF!��•'��/ ACKNOWLEDGED BEFORE ME THIS v' DAY OF 20 I J , BY l/v �� ` U WHO IS PERSONALLY KNOWN TO ME OR WHO HAS PRODUCED AS ID N F IO BNDI R. McLOUGHLIN NARY PUBLIC (seal) SIGNA OF NOT Y *E7xplres it I Comm# DD935088 COMMISSION NUMBER 1Q/21J2013 In NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. EXEMPT: A/C -HEAT REPLACEMENT WITH CONTRACT UNDER $7500.00 Revised 04/26/2010 Property Appraiser - St.Lucie Cc y, FL Page 1 of 1 PROPERTY RECORD CARD Marilyn Melching Record: 1 of 1 <<Prev Next» Spec.Assmnt Taxes Exemptions Permits Home Print Property Identification ,��,UOfECO Site Address: Sec/TownlRange: 8206 E Bitterbush Ln 25 :36S :40E ParcellD: 3425-701-0070-000-7 Account #: 115080 y Map ID: 34/25S Use Type: Mob Homes Zoning: PUD City/Cnty: St Lucie County' Ownership and Mailing Legal Description Owner: Marilyn Melching Teresa J Melching SAVANNA CLUB -PLAT ONE- BLK 2 LOT26 (OR 3504-196) Address: 8206 E Bitterbush Ln Port St Lucie FL 34952 Sales Information Assessment2012 Total Land and Building Date Price Code Deed Book/Page 2012 Final: 47700 Land Value: 13000 Acres: 0.11 3/19/2013 23900 0116 LE 3504 / 0196 Assessed: 47700 Building Value: 34700 3/19/2013 0 0116 LE 3504 / 0193 Ag.Credit: 0 Finished Area: 1144 SgFt 2/13/2013 41600 0116 LE 3490 / 0460 Exempt: 1/19/2012 100 0111 CT 3367 / 0037 Taxable: 12/9/2011 0 0111 MS 3351 / 1323 Taxes: 965 11/30/2011 0 0111 FJ 3349 / 0335 9/25/2001 60000 01 LE 1440 / 0671 9/25/2001 0 01 LE 1440 / 0669 9/19/2000 62200 01 LE 1330 / 308 7/21/1999 58000 01 WD 1239 / 0568 5/9/1995 0 01 WD 0955 / 0674 2/1/1986 15000 01 CV 0491 / 1969 BUILDING INFORMATION Exterior Features View: - RoofCover: - RoofStruct: ExtType: MHA - MHA YearBlt: 1985 Frame: - Grade: SAVL - SAVL EffYrBit: 1985 PrimeWall: StoryHght: 0010 - 1 Story No.Units: 1 SecWall: Interior Features BedRooms: 0 Electric: - PrmintWall: - FullBath: 0 HeatType: FHA - FrcdHotAir AvgHt/FI: 1/2Bath: 0 HeatFuel: ELEC - Electric Prm.Flors: - %A/C: 100 %Heated: 100 %Sprinkled: 0 Special Features and Yard Items Land Information Type Y/S Qty. Units Qual. Cond. YrBlt. No. Use Type Type Measure Depth 1 0200-Mob Homes 154 -Flat 1 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED. http://www.paslc.org/paslc/prc.asp?prclid=342570100700007 5/28/2013 Pro ect Summary Job: M 2 -- wrightsoft� Ent re House � Byte: Ma 28 , 2013 SERVICE AMERICA 2755 NW 63RD COURT, FORT LAUDERDALE, FL 33309 Phone: 954-979-1100 Fax: 954-977-3591 Email: epermitsgroup@serviceamerica.com License: CAC014619 Project• • For: MELCHING, THERESA 8206 E BITTERBUSH LN, PORT SAINT LUCIE, FL 34952-3315 Phone:772-446-9335 Notes:, (^ f` Weather: West Palm Beach. Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 48 OF Inside db 70 OF Design TD 22 OF Heating Summary Structure 8644 Btuh Ducts 4096 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 12740 Btuh Infiltration Outside db Inside db Design TD 90 75 15 OF OF OF Daily range Relative humidity L 50 % Moisture difference 59 gr/lb Sensible Cooling Equipment Load Sizing Structure 21467 Btuh Ducts 6879 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 26985 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2446 Btuh Ducts 1788 Btuh Heating Coolingg Central vent (0 cfm) load 0 Btuh Btuh Area (ft2 1213 1213 Equipment latent 4234 Volume (ft3) 10681 10681 Air changes/hour 0.45 0.23 Equipment total load 31219 Btuh Equiv. AVF (cfm) 80 41 Req. total capacity at 0.70 SHR 3.2 ton Heating Equipment Summary Cooling Equipment Summary Make Make RHEEM Trade Trade RHEEM RSNM SERIES Model Cond RSNM-A036JK AHRI ref Coil AHRI ref 1076041 Efficiency 80AFUE Efficiency 11.3 EER, 13 SEER Heating input 0 MBtuh Sensible cooling 25060 Btuh Heating output 0 Btuh Latent cooling 10740 Btuh Temperature rise 0 OF Total cooling 35800 Btuh Actual air flow 1197 cfm Actual air flow 1197 cfm Air flow factor 0.094 cfm/Btuh Air flow factor 0.042 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.87 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrl htsoft° 2013-May-2812:14:03 g Right -Suite® Universal 2012 12.1.06 RSU15991 Page 1 ACCK W:\Wright Soft FPL Heat LoaW3562274.rup Calc = MJ8 Front Door faces: N Certificate of Product Ratings AHRI Certified Reference Number: 1076041 Date: 5/28/2013 Product: Year -Round Single -Package Air -Conditioner, Air -Cooled Model Number: RSNM-A036JK Manufacturer: RHEEM MANUFACTURING COMPANY Trade/Brand name: RHEEM RSNM SERIES Manufacturer responsible for the rating of this system combination is RHEEM MANUFACTURING COMPANY Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air -Conditioning and Air -Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): 35800 EER^Rating,_(Cooling):. SEER Rating (Cooling): 13.00 i ! x Ratings followed by an asterisk (•) indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out ofthe use or performance ofthe product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed In the directory at wwwahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, In whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION®/ The information forthe model cited on this certificate can be verified atwww.ahridirectory.org, Air -Conditioning, Heating, click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on A. 00 IL' and Refrigeration Institute which the certificate was issued, which is listed above, and the Certificate No., which is listed below. 02013 Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130142294993439300