HomeMy WebLinkAboutSUBMITTED PAPERSr
Due: Recei t# Permit #
1�
Planning & Development Services
Building & Code Regulations Division
2300 Virginia Ave.
Fort Pierce, FL 34982
(772)462-1553 St �UprG CpUnt
y
SPECIALTY.PERMIT APPLICATION
❑ Electrical ❑ Plumbing 'PHVAC ❑ Fence
❑ Shed ❑ Demolition ❑ Gas ❑ Siding
See page 2 for instructions and additional paperwork required for specialty permits
1. Location/Site Address: 02, 91 / �5�h,ertA. aid. L4.n e,
2. Parcel ID Number: C C ?02-j — W { " 60.� 5 " Q04�) -CQ
Office Use
Only
Section
Township
Range
Map Page
S
Land Use
Initials
3. Complete Description of Proj�jct or Work: ,41 JCG
2 c' rrr A l / 1 �1 li a r ' A � e^ - - -
4. Owners Information 5. Contractors Information
Name: _TVA6n-V c,5 c�TG l I � , S FL Reg/Cert #: L`f 05?g(o 5
Address: - L / r% <Sh erajood-, /^^ 'e- _ _ _ _ County Cert#: C,2 91/0 P
City: r-,' - Pi dat- State: k- Business Name: P'% )7etl cc,-) 4yjy 9&,e_-*% G
Zip: 34q 9A Phone: ,Phone: 979>-51g3 Fax: p-)o&-` jjq
6. Value of Construction: S 59 4 t, 7,T-
owNEws AFFIDAvrr: I certify that all of the information contained in this application is correct and that all work will be done In
/f compliance with all applicable laws`iegulating construction and zoning.
�ii•PS
PRINT OWNER OR CO CTOR NS�A /ME SI TR R OR C NACTOR
STATE OF FLORIDA, COUNTY OF _JT Louts -
ACKNOWLEDGED BEFORE ME THIS 63�DAY OF 20 t 3 . BY J [3.MiGS
WHO IS PERSONALLY KNOWN TO ME V-) OR WHO HAS PRODUCED
S IHCATION.1161
CGERI L. ALHOUN
6
Florida-
(seal)AGNOTARY W s Oct 6, 2015
COMMISSION NUMBER L7 1D,59426 ' 9f a Commission # EE 105900
It ��'Banded Through National Notary Assn.
NOTICE TO OWNER FAILURE TO RECORD A NOTI F C YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR
LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
EXEMPT: A/C -HEAT REPLACEMENT WITH CONTRACT UNDER $7500.00
Revised 04/26/2010
06/03/2013 10:37
7724621148
ST LUC1E COUNTY
PAGE 02/02
ls'o
��"
i' wrightsoft"
Right J® Mobile Report
Job: 3137
Bate:
Entire House
By: Chrls Fontana
Chris
All American Air and Electric
5761 Nw Mercantile Place d111, PON Saint Lucie, FL 34a08 shone: 772.878-3143 Fax: 772-M-5144 Email: Jcolhoun®naaelnc.com License: Car�57955
Project•
•
For:
THOMAS JAY
2917 Sherwood lane. Fort Pierce, FL 34962
Phone: 772-464-OWS
Design Conditions
Location:
Indoor:
Heating
Cooling
Vero Beach Municipal
AP, FL, US
Indoor temperature ("F)
70
75
Elevation: 23 ft
Design TO (aF)
25
16
Latitude: 281N
Relative humidity (%)
30
50
Outdoor:
Heating Cooling
Moisture difference (gr/lb)
-2.7
59,2
Dry bul b ("F)
45 91
Infiltration:
Dailyrange ('F)
- 15 (1 )
Method
Simplified
Wet bulb ("F)
- 78
Construction quality
Average
Wind speed (mph)
15.0 7.5
Fireplaces
0
Heating
Component
Btuh/ft'•
Stuh
% of load
Walls
4.2
6379
13.0
Glazing
27.0
3240
7.8
Doors
15.0
473
1,1
Ceilings
2.8
5250
12.7
Floors
13.0
24422
59.0
Infiltration
1.8
2610
6.3
Ducts
0
0
Piping
0
0
Humidification
0
0
Ventilation
0
0
Adjustments
0
Total
1 413741
100.0
Cooling
Component
Eltuh/ft'
Stuh
% of load
Walls
3.0
3862
10.5
Glazing
41.0
4923
13.4
Doors
17.5
551
1,5
Ceilings
5.9
11057
30.1
Floors
6.6
12357
33.7
Infiltration
0.6
857
2.3
Ducts
0
0
Ventilation
0
0
Intemal gains
3090
8.4
Blower
0
0
Adjustments
0
Total
1
1 306971
100.0
Latent Cooling Load = 2810 Btuh
Overall U-value=0.299Btuhlft'-aF
Data entries checked.
WIS Jrilltatim
oanr�.
Ow
C OIMS
Floors
aher _ .
Guldgtallc values havc been Manually oVerrldden
• "J"
as
Vlril 11t90ft 2013-May-3O 06:04:02
g Rlpht-Sulla0 Unlver�al 2012 12.1.07 Right JO Nbbliq Peon 1
..lwstmn1a33016l48loo-46cl-b37c-f4ed649b6862.rup Calc=MJ8 FrontDoorfecw: E
Right JO Mobile Report Job: 5437
wrghtsoft'
Date: 5130/2013
Entire House By: Chris Fontana
All American Air and Electric
575 Nw Mercantile Place #111, Port Saint Lucie, FL 34986 Phone: 772-878-5143 Fax: 772-878-5144 Email: Jcalhoun@aaaeinc.com License: Cac057965
For: THOMAS JAY
2917 Sherwood lane, Fort Pierce, FL 34982
Phone: 772-464-0968
Location:
Vero Beach Municipal AP, FL, US
Elevation: 23 ft
Latitude: 28 °N
Outdoor: Heating Cooling
Dry bulb (°F) 45 91
Daily range (°F) - 16 ( L
Wet buIb(°F) - 78
Wind speed (mph) 15.0 7.5
Component
Btuh/ftz
Btuh
% of load
Walls
4.2
5379
13.0
Glazing
27.0
3240
7.8
Doors
15.0
473
1.1
Ceilings
2.8
5250
12.7
Floors
13.0
24422
59.0
Infiltration
1.8
2610
6.3
Ducts
0
0
Piping
0
0
Humidification
0
0
Ventilation
0
0
Adjustments
0
Total
41374
100.0
Component
Btuh/ft2
Btuh
% of load
Walls
3.0
3862
10.5
Glazing
41.0
4923
13.4
Doors
17.5
551
1.5
Ceilings
5.9
11057
30.1
Floors
6.6
12357
33.7
Infiltration
0.6
857
2.3
Ducts
0
0
Ventilation
0
0
Internal gains
3090
8.4
Blower
0
0
Adjustments
0
Total
36697
100.0
Latent Cooling Load = 2610 Btuh
Overall U-\ralue =0.299 Btuh/fF--'F
Data entries checked.
Indoor:
Indoor temperature (°F)
Design TD (°F)
Relative humidity (%)
Moisture difference (gr/lb)
Infiltration:
Method
Construction quality
Fireplaces
_111 W
Bold/italic values have been manually overridden
Heating
70
25
30
-2.7
Simplified
Average
0
Cooling
75
16
50
59.2
.y {JVi'1 ht50 2013-May-30 06:04:02
Right -Suite® Universal 2012 12.1.07 Right J® Mobile Page 1
...\wstmp\a330f6l4-8lea-45cl-b37c-f4ed649b6862.rup Calc = MJ8 Front Door faces: E
Project Summary Job: 5437
Wri htsoft� Date: 5/30/2013
Entire House By: Chris Fontana
All American Air and Electric
575 Nw Mercantile Place #111, Port Saint Lucie, FL 34986 Phone: 772-878-5143 Fax: 772-878-5144 Email: Jcalhoun@aaaeinc.com License: Cac057965
® e
For: THOMAS JAY
2917 Sherwood lane, Fort Pierce, FL 34982
Phone: 772-464-0968
Notes:
6E Si ,n.
.. InfiorrnatIoil
Weather: Vero Beach Municipal AP, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db
45 °F
Outside db
91
°F
Inside db
70 °F
Inside db
75
°F
Design TD
25 °F
Design TD
16
°F
Daily range
L
Relative humidity
50
%
Moisture difference
59
gr/lb
Heating
Summary
Sensible Cooling Equipment Load
Sizing
Structure
41374 Btuh
Structure
36697
Btuh
Ducts
0 Btuh
Ducts
0
Btuh
Central vent (0 cfm)
0 Btuh
Central vent (0 cfm)
0
Btuh
Humidification
0 Btuh
Blower
0
Btuh
Piping
0 Btuh
Equipment load
41374 Btuh
Use manufacturer's data
y
Rate/swing multiplier
1.00
Infiltration
Equipment sensible load
36697
Btuh
Method
Simplified
Latent Cooling Equipment Load
Sizing
Construction quality
Average
Fireplaces
0
Structure
2610
Btuh
Ducts
0
Btuh
Heating Cooling
Central vent (0 cfm)
0
Btuh
Area (ftz)
1875 1875
Equipment latent load
2610
Btuh
Volume (It)
15000 15000
Air changes/hour
0.38 0.20
Equipment total load
39308
Btuh
Equiv. AVF (cfm)
95 50
Req. total capacity at 0.76 SHR
4.0
ton
Heating Equipment Summary
Cooling Equipment Summary
Make Goodman
Make Goodman
Trade Amana
Trade Amana
Model Aruf42c14
Cond Gsx130421
AHRI ref 5360116
Coil Capf3743c6
AHRI ref 5360116
Efficiency
0 AFUE
Efficiency
13 SEER
Heating input
0 MBtuh
Sensible cooling
30139
Btuh
Heating output
0 Btuh
Latent cooling
9362
Btuh
Temperature rise
0 °F
Total cooling
39500
Btuh
Actual air flow
1669 cfm
Actual air flow
1669
cfm
Air flow factor
0.040 cfm/Btuh
Air flow factor
0.045
cfm/Btuh
Static pressure
0 in H2O
Static pressure
0
in H2O
Space thermostat
Load sensible heat ratio
0.93
Bold/italic values have been manually overridden
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
r4 iritgtt t ft'
2013-Ma 30 06:04:02
Y
Right -Suite@ Universal 2012 12.1.07 Right J@
Mobile
Page 1
\wstmp\a330f6l4-8lea-45cl-b37c-f4ed649b6862.rup Calc=MJ8 FrontDoorfaces:
E
-+wre htsoft° Right -A) Worksheet Job: 5437
Entire House Date: 5/30/2013
All American Air and Electric By: Chris Fontana
575 Nw Mercantile Place #111, Port Saint Lucie, FL 34986 Phone: 772-878-5143 Fax: 772-878-5144 Email: Jcalhoun@aaaeinc.com License: Cac057965
1 Room name Entire House First Floor
2 Exposed wall 180.0 ft 180.0 ft
3 Room height 8.0 ft 8.0 ft heat/cool
4 Room dimensions 1.0 x 1875.0 ft
5 Room area 1875.0 ft' 1875.0 ft'
Ty
Construction
U-value
Or I
HTM
I
Area (ft')
I
Load
I
Area (ft2)
I
Load
number
(Btuh/W-°F)
(Btuh/ft')
or perimeter
(ft)
(Btuh)
or perimeter
(ft)
(Btuh)
Heat
Cool
Gross
I N/P/S j
Heat I
Cool j
Gross
I N/P/S
j
Heat
Cool
6
13A'3ocs`
0167
n
4.17
3.06
360
349
.14V
1646
360
349
" >1457
1046
1Actob
1080
. n-
27.00
23'73
-2
0
54
47
2
0
.
54
_
47
1A clob
1.Ot30,
n_=
27.00:
23.73
'9
0
243
�_ = 214,
9
' -
0
- .-243
_
214
13A-3ocs
0.167
a
4.17
3.00
360
317
1323
950
360
317
1323
950
11
to-clob
1.080
a
27.00
60.27
2
0
54
121
2
0
54
121
to-ctob
1.080
a
27.00
60.27
9
0
243
542
9
0
243
542
IA-cl ob _
1.080
e
27.00
23.73
32
32
864
759
32
32
864
759
`
13A 3ocs
0 167
,
, s s
4.17
.I0i)
36b
,
,
299
�'-1,246
895
360
299
.-i
1246
89
lA-slob'
' "1 080
,s:'
27.40�
: 23.73.
1�2
12
;'� 324
285
12
12
„
324s
.
285
1/kclob
1 080
s
27 00
25.73'-
6
;162
154
6
6
162=
:'
154
i4clob,_
a'
1,080
;. s`<
27.00
20,b
- .12
12
324
309
12
12
324
309
..11J0
0.600
s• =
', ..15.00
17SA9
- 32
::
' 32
:` ,473
•551.
' 32
• _ 1`
32
'.
' 473`,
:
,.' 661
13A-3ocs
0.167
w
4.17
3.00
360
324
1353
971
360
324
1353
971
1A-c11ob
1.080
w
27.00
54.30
12
2
324
652
12
2
324
652
1A-c1ob
1.080
w
27.00
60.27
24
0
648
1446
24
0
648
1446
C, :. ;.
'16B-lad" -:,
0 112
2.81
'-5.90.!
1875
,,,
1875
5250
11057
,",' 1875
`:
1875
`•
5250;
11057
F
20P70t
0:521
1,3.03
6.59
.1875
1875
.24422 ,
1,2357
1875
1875
24422.
12357
61
c) AED excursion
1
3931
393
Envelope loss/gain
1
38764
32750
1
1
38764
32750
12
a) Infiltration
2610
857
2610
857
b) Room ventilation
0
0
0
0
13
Internal gains:
Occupants @
230
3
690
3
690
Appliances/other
2400
2400
Subtotal (lines 6 to 13)
41374
36697
41374
36697
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
41374
36697
41374
36697
15
Dud loads
0%
0%
0
0
-0%
0%
0
0
Total room load
41374
366971
41374
36697
Air required (dm)
I
I
I
1669
1669
I
1669
1669
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
- - Wrlights `sfFt ' 2013-May-30 06:04:02
Rig ht-SuiteO Universal 2012 12.1.07 Right AMobile Page 1
\wstmp\a330f6l4-8lea-45cl-b37c-f4ed64gb6862.rup Calc=MJ8 FrontDoorfaces: E
Job: 5437
.. eightsome Component Constructions Date: 530/2013
Entire House By: Chris Fontana
All American Air and Electric
575 Nw Mercantile Place #111, Port Saint Lucie, FL 34986 Phone: 772-878-5143 Fax: 772-878-5144 Email: Jcalhoun@aaaeinc.com License: Cac057965
For: THOMAS JAY
2917 Sherwood lane, Fort Pierce, FL 34982
Phone: 772-464-0968
Msign1tion,
Location:
Indoor:
Heating
Cooling
Vero Beach Municipal AP, FL, US
Indoor temperature (°F)
70
75
Elevation: 23 ft
Design TD (°F)
25
16
Latitude: 28°N
Relative humidity (%)
30
50
Outdoor: Heating
Cooling
Moisture difference (gr/lb)
-2.7
59.2
Dry bulb (°F) 45
91
Infiltration:
Dailyrange (°F) -
16 ( L
)
Method
Simplified
Wetbulb (°F) -
78
Construction quality
Average
Wind speed (mph) 15.0
7.5
Fireplaces
0
Construction descriptions
Or
Area
U-value Insul R
Htg HTM Loss
Clg HTM Gain
ft'
Btuh/ft'-°F ft'-°FBluh
Btuh/ft- Btuh
Btuh/ft' Btuh
Walls
13A-3ocs: Blk wall, stucco ext, r-3 ext bd ins, 6" thk, 1/2"
gypsum
n
349
0.167 3.0
4.17 1457
3.00 1046
board int fnsh
a
317
0.167 3.0
4.17 1323
3.00 950
s
299
0.167 3.0
4.17 1246
3.00 895
w
324
0.167 3.0
4.17 1353
3.00 971
all
1289
0.167 3.0
4.17 5379
3.00 3862
Partitions
(none)
Windows
1A-clob: 1 glazing, clr glz, mtl /w brk frm mat, 1/8" thk; 50% blinds
closed, light; 50% outdoor insect screen; 2 ft overhang (2 ft window
ht, 2 ft sep.)
1A-clob: 1 glazing, clr glz, mtl /w brk firm mat, 1/8" thk; 50% blinds
closed, light; 50% outdoor insect screen; 2 ft overhang (3 ft window
ht, 2 ft sep.)
IA-c1ob: 1 glazing, clr glz, mtl /w brk frm mat, 1/8" thk; 50% blinds
closed, light; 50% outdoor insect screen; 8 ft overhang (4 ft window
ht, 2 ft sep.)
1A-clob: 1 glazing, clr glz, mtl /w brk frm mat, 1/8" thk; 50% blinds
closed, light; 50% outdoor insect screen; 5 ft overhang (4 ft window
ht, 3 ft sep.)
1A-c1ob: 1 glazing, clr glz, mtl /w brk frm mat, 1/8" thk; 50% blinds
closed, light; 50% outdoor insect screen; foreground = green grass
(0.23); 2 ft overhang (3 ft window ht, 1 ft sep.)
IA-c1ob: 1 glazing, clr glz, mtl /w brk frm mat, 1/8" thk; 50% blinds
closed, light; 50% outdoor insect screen; foreground = green grass
(0.23); 2 ft overhang (4 ft window ht, 3 ft sep.)
1A-c1ob: 1 glazing, clr glz, mtl /w brk frm mat, 1/8" thk; 50% blinds
closed, light; 50% outdoor insect screen; 3 ft overhang (3 ft window
ht, 2 ft sep.)
1A-c1ob: 1 glazing, cir giz, mtl /w brk frm mat, 1/8" thk; 50% blinds
closed, light; 50% outdoor insect screen; 2 ft overhang (6 ft window
ht, 2 ft sep.)
n 2
1.080
0
27.0
54
23.7
47
e 2
1.080
0
27.0
54
60.3
121
all 4
1.080
0
27.0
108
42.0
168
n 9
1.080
0
27.0
243
23.7
214
e 9
1.080
0
27.0
243
60.3
542
all 18
1.080
0
27.0
486
42.0
756
e 32
1.080
0
27.0
864
1 23.7
759
s 12
1.080
0
27.0
324
23.7
285
s 6
1.080
0
27.0
162
25.7
154
s 12
1.080
0
27.0
324
25.7
309
w 12
1.080
0
27.0
324
54.3
652
w 24
1.080
0
27.0
648
60.3
1446
Bold/italic values have been manually overridden
2013-Ma 30 06:04:03
wrl!g tso Right -Suite@ Universal 2012 12.1.07 Right J® Mobile y Page 1
\wstmp\a330f6l4-8lea-45cl-b37c-f4ed64gb6862.rup Calc=MJ8 FrontDoorfaces: E
Doors
11JO: Door, mtl fbrgl type
Ceilings
166-7ad: Attic ceiling, asphalt shingles roof mat, r-7 ceil ins, 1/2"
gypsum board int fnsh
Floors
20P-0t: Fir floor, wd fir, 1" thkns, tile flr fnsh, amb ovr
s 32 0.600 6.3 15.0 473 17.5 551
1875 0.112 7.0 2.80 5250 5.90 11057
1875 0.521 0 13.0 24422 6.59 12357
Bold/italic values have been manually overridden
2013-May-30 06:04:03
,,�°`_ft' Right-Suite®Universal 2012 12:1.07 Right J® Mobile Page 2
lwstmpNa330f6l4-8lea-45cl-b37c-f4ed649b6862.rup Calc=MJ8 FrontDoorfaces: E
6
AED Assessment Job: 537
'�`ightso'� Date: 5/3012013
Entire House By: Chris Fontana
All American Air and Electric
575 Nw Mercantile Place #111, Port Saint Lucie, FL 34986 Phone: 772-878-5143 Fax: 772-878-5144 Email: Jcalhoun@aaaeinc.com License: Cac057965
For: THOMAS JAY
2917 Sherwood land, Fort Pierce, FL 34982
Phone: 772-464-096I8
Location:
Vero Beach Municipal AP, FL, US
Elevation: 23 ft
Latitude: 28 °N
Outdoor: Heating
Dry bulb (°F) 45
Dailyrange (°F) -
Wet bulb (°F) -
Wind speed (mph) 15.0
7,00
6700
5700
4,00
3100
2,00
1,00
re
Indoor:
Heating
Cooling
Indoor temperature (°F)
70
75
Design TD (°F)
25
16
Relative humidity (%)
30
50
Cooling
Moisture difference (gr/lb)
-2.7
59.2
91
Infiltration:
16 (L )
78
7.5
Hourly Glazing Load
9 1011 12 13 14
Hour of Day
15 16 17 18 19 20
/ FbLdy / Aerage / PFDlimit
Maximum hourly glazing load exceeds average by 38.2%.
House does not have adequate exposure diversity (AED), based on AED limit of 30%.
AED excursion: 393 Btuh (PFG-1.3*AFG)
Bold/italic values have been manually overridden
2013-May-30 06:04:03
1d r1ght90't" Right -Suite@ Universal 2012 12.1.07 Right J@ Mobile Page 1
...lwstmp\a330f6l4-8lea-45cl-b37c-f4ed649b6862.rup Caic=MJ8 FrontDoorfaces: E
Certificate of Product Ratings
AHRI Certified Reference Number: 5360116 Date: 5/30/2013
Product: Split System: Air -Cooled Condensing Unit, Coil with Blower
Outdoor Unit Model Number: GSX130421B*
Indoor Unit Model Number: ARUF42C14A*
Manufacturer: GOODMAN MANUFACTURING CO., LP.
Trade/Brand name: GOODMAN, JANITROL, AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR
CONDITIONING AND HEATING, ENERGI AIR
Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP.
Rated as follows in accordance with AHRI Standard 2101240-2008 for Unitary Air -Conditioning and Air -Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third
party testing:
Cooling Capacity (Btuh): 39500
EER Rating (Cooling): 11.00
SEER Rating (Cooling): 13.00
* Ratings followed by an asterisk (*) Indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate
DISCLAIMER
AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for,
the products) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the
unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products ofAHRI. This Certificate shall only be used for individual, personal and confidential reference purposes.
The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any
form or manner or by any means, except for the user's Individual, personal and confidential reference.
CERTIFICATE VERIFICATION
The information forthe model cited on this certificate can be verified atwwwahridirectoryorg, A "IM' Air -Conditioning, Heating,
click on'Nerify Certificate" link and entertheAHRI Certified Reference Number and the date on A. an ,' and Refrigeration Institute
which the certificate was issued, which is listed above, and the Certificate No., which is listed below.
02013 Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130143971098756692