Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSr Due: Recei t# Permit # 1� Planning & Development Services Building & Code Regulations Division 2300 Virginia Ave. Fort Pierce, FL 34982 (772)462-1553 St �UprG CpUnt y SPECIALTY.PERMIT APPLICATION ❑ Electrical ❑ Plumbing 'PHVAC ❑ Fence ❑ Shed ❑ Demolition ❑ Gas ❑ Siding See page 2 for instructions and additional paperwork required for specialty permits 1. Location/Site Address: 02, 91 / �5�h,ertA. aid. L4.n e, 2. Parcel ID Number: C C ?02-j — W { " 60.­� 5 " Q04�) -CQ Office Use Only Section Township Range Map Page S Land Use Initials 3. Complete Description of Proj�jct or Work: ,41 JCG 2 c' rrr A l / 1 �1 li a r ' A � e^ - - - 4. Owners Information 5. Contractors Information Name: _TVA6n-V c,5 c�TG l I � , S FL Reg/Cert #: L`f 05?g(o 5 Address: - L / r% <Sh erajood-, /^^ 'e- _ _ _ _ County Cert#: C,2 91/0 P City: r-,' - Pi dat- State: k- Business Name: P'% )7etl cc,-) 4yjy 9&,e_-*% G Zip: 34q 9A Phone: ,Phone: 979>-51g3 Fax: p-)o&-` jjq 6. Value of Construction: S 59 4 t, 7,T- owNEws AFFIDAvrr: I certify that all of the information contained in this application is correct and that all work will be done In /f compliance with all applicable laws`iegulating construction and zoning. �ii•PS PRINT OWNER OR CO CTOR NS�A /ME SI TR R OR C NACTOR STATE OF FLORIDA, COUNTY OF _JT Louts - ACKNOWLEDGED BEFORE ME THIS 63�DAY OF 20 t 3 . BY J [3.MiGS WHO IS PERSONALLY KNOWN TO ME V-) OR WHO HAS PRODUCED S IHCATION.1161 CGERI L. ALHOUN 6 Florida- (seal)AGNOTARY W s Oct 6, 2015 COMMISSION NUMBER L7 1D,59426 ' 9f a Commission # EE 105900 It ��'Banded Through National Notary Assn. NOTICE TO OWNER FAILURE TO RECORD A NOTI F C YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. EXEMPT: A/C -HEAT REPLACEMENT WITH CONTRACT UNDER $7500.00 Revised 04/26/2010 06/03/2013 10:37 7724621148 ST LUC1E COUNTY PAGE 02/02 ls'o ��" i' wrightsoft" Right J® Mobile Report Job: 3137 Bate: Entire House By: Chrls Fontana Chris All American Air and Electric 5761 Nw Mercantile Place d111, PON Saint Lucie, FL 34a08 shone: 772.878-3143 Fax: 772-M-5144 Email: Jcolhoun®naaelnc.com License: Car�57955 Project• • For: THOMAS JAY 2917 Sherwood lane. Fort Pierce, FL 34962 Phone: 772-464-OWS Design Conditions Location: Indoor: Heating Cooling Vero Beach Municipal AP, FL, US Indoor temperature ("F) 70 75 Elevation: 23 ft Design TO (aF) 25 16 Latitude: 281N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) -2.7 59,2 Dry bul b ("F) 45 91 Infiltration: Dailyrange ('F) - 15 (1 ) Method Simplified Wet bulb ("F) - 78 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Heating Component Btuh/ft'• Stuh % of load Walls 4.2 6379 13.0 Glazing 27.0 3240 7.8 Doors 15.0 473 1,1 Ceilings 2.8 5250 12.7 Floors 13.0 24422 59.0 Infiltration 1.8 2610 6.3 Ducts 0 0 Piping 0 0 Humidification 0 0 Ventilation 0 0 Adjustments 0 Total 1 413741 100.0 Cooling Component Eltuh/ft' Stuh % of load Walls 3.0 3862 10.5 Glazing 41.0 4923 13.4 Doors 17.5 551 1,5 Ceilings 5.9 11057 30.1 Floors 6.6 12357 33.7 Infiltration 0.6 857 2.3 Ducts 0 0 Ventilation 0 0 Intemal gains 3090 8.4 Blower 0 0 Adjustments 0 Total 1 1 306971 100.0 Latent Cooling Load = 2810 Btuh Overall U-value=0.299Btuhlft'-aF Data entries checked. WIS Jrilltatim oanr�. Ow C OIMS Floors aher _ . Guldgtallc values havc been Manually oVerrldden • "J" as Vlril 11t90ft 2013-May-3O 06:04:02 g Rlpht-Sulla0 Unlver�al 2012 12.1.07 Right JO Nbbliq Peon 1 ..lwstmn1a33016l48loo-46cl-b37c-f4ed649b6862.rup Calc=MJ8 FrontDoorfecw: E Right JO Mobile Report Job: 5437 wrghtsoft' Date: 5130/2013 Entire House By: Chris Fontana All American Air and Electric 575 Nw Mercantile Place #111, Port Saint Lucie, FL 34986 Phone: 772-878-5143 Fax: 772-878-5144 Email: Jcalhoun@aaaeinc.com License: Cac057965 For: THOMAS JAY 2917 Sherwood lane, Fort Pierce, FL 34982 Phone: 772-464-0968 Location: Vero Beach Municipal AP, FL, US Elevation: 23 ft Latitude: 28 °N Outdoor: Heating Cooling Dry bulb (°F) 45 91 Daily range (°F) - 16 ( L Wet buIb(°F) - 78 Wind speed (mph) 15.0 7.5 Component Btuh/ftz Btuh % of load Walls 4.2 5379 13.0 Glazing 27.0 3240 7.8 Doors 15.0 473 1.1 Ceilings 2.8 5250 12.7 Floors 13.0 24422 59.0 Infiltration 1.8 2610 6.3 Ducts 0 0 Piping 0 0 Humidification 0 0 Ventilation 0 0 Adjustments 0 Total 41374 100.0 Component Btuh/ft2 Btuh % of load Walls 3.0 3862 10.5 Glazing 41.0 4923 13.4 Doors 17.5 551 1.5 Ceilings 5.9 11057 30.1 Floors 6.6 12357 33.7 Infiltration 0.6 857 2.3 Ducts 0 0 Ventilation 0 0 Internal gains 3090 8.4 Blower 0 0 Adjustments 0 Total 36697 100.0 Latent Cooling Load = 2610 Btuh Overall U-\ralue =0.299 Btuh/fF--'F Data entries checked. Indoor: Indoor temperature (°F) Design TD (°F) Relative humidity (%) Moisture difference (gr/lb) Infiltration: Method Construction quality Fireplaces _111 W Bold/italic values have been manually overridden Heating 70 25 30 -2.7 Simplified Average 0 Cooling 75 16 50 59.2 .y {JVi'1 ht50 2013-May-30 06:04:02 Right -Suite® Universal 2012 12.1.07 Right J® Mobile Page 1 ...\wstmp\a330f6l4-8lea-45cl-b37c-f4ed649b6862.rup Calc = MJ8 Front Door faces: E Project Summary Job: 5437 Wri htsoft� Date: 5/30/2013 Entire House By: Chris Fontana All American Air and Electric 575 Nw Mercantile Place #111, Port Saint Lucie, FL 34986 Phone: 772-878-5143 Fax: 772-878-5144 Email: Jcalhoun@aaaeinc.com License: Cac057965 ® e For: THOMAS JAY 2917 Sherwood lane, Fort Pierce, FL 34982 Phone: 772-464-0968 Notes: 6E Si ,n. .. InfiorrnatIoil Weather: Vero Beach Municipal AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 45 °F Outside db 91 °F Inside db 70 °F Inside db 75 °F Design TD 25 °F Design TD 16 °F Daily range L Relative humidity 50 % Moisture difference 59 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 41374 Btuh Structure 36697 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 41374 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 36697 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2610 Btuh Ducts 0 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ftz) 1875 1875 Equipment latent load 2610 Btuh Volume (It) 15000 15000 Air changes/hour 0.38 0.20 Equipment total load 39308 Btuh Equiv. AVF (cfm) 95 50 Req. total capacity at 0.76 SHR 4.0 ton Heating Equipment Summary Cooling Equipment Summary Make Goodman Make Goodman Trade Amana Trade Amana Model Aruf42c14 Cond Gsx130421 AHRI ref 5360116 Coil Capf3743c6 AHRI ref 5360116 Efficiency 0 AFUE Efficiency 13 SEER Heating input 0 MBtuh Sensible cooling 30139 Btuh Heating output 0 Btuh Latent cooling 9362 Btuh Temperature rise 0 °F Total cooling 39500 Btuh Actual air flow 1669 cfm Actual air flow 1669 cfm Air flow factor 0.040 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.93 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. r4 iritgtt t ft' 2013-Ma 30 06:04:02 Y Right -Suite@ Universal 2012 12.1.07 Right J@ Mobile Page 1 \wstmp\a330f6l4-8lea-45cl-b37c-f4ed649b6862.rup Calc=MJ8 FrontDoorfaces: E -+wre htsoft° Right -A) Worksheet Job: 5437 Entire House Date: 5/30/2013 All American Air and Electric By: Chris Fontana 575 Nw Mercantile Place #111, Port Saint Lucie, FL 34986 Phone: 772-878-5143 Fax: 772-878-5144 Email: Jcalhoun@aaaeinc.com License: Cac057965 1 Room name Entire House First Floor 2 Exposed wall 180.0 ft 180.0 ft 3 Room height 8.0 ft 8.0 ft heat/cool 4 Room dimensions 1.0 x 1875.0 ft 5 Room area 1875.0 ft' 1875.0 ft' Ty Construction U-value Or I HTM I Area (ft') I Load I Area (ft2) I Load number (Btuh/W-°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross I N/P/S j Heat I Cool j Gross I N/P/S j Heat Cool 6 13A'3ocs` 0167 n 4.17 3.06 360 349 .14V 1646 360 349 " >1457 1046 1Actob 1080 . n- 27.00 23'73 -2 0 54 47 2 0 . 54 _ 47 1A clob 1.Ot30, n_= 27.00: 23.73 '9 0 243 �_ = 214, 9 ' - 0 - .-243 _ 214 13A-3ocs 0.167 a 4.17 3.00 360 317 1323 950 360 317 1323 950 11 to-clob 1.080 a 27.00 60.27 2 0 54 121 2 0 54 121 to-ctob 1.080 a 27.00 60.27 9 0 243 542 9 0 243 542 IA-cl ob _ 1.080 e 27.00 23.73 32 32 864 759 32 32 864 759 ` 13A 3ocs 0 167 , , s s 4.17 .I0i) 36b , , 299 �'-1,246 895 360 299 .-i 1246 89 lA-slob' ' "1 080 ,s:' 27.40� : 23.73. 1�2 12 ;'� 324 285 12 12 „ 324s . 285 1/kclob 1 080 s 27 00 25.73'- 6 ;162 154 6 6 162= :' 154 i4clob,_ a' 1,080 ;. s`< 27.00 20,b - .12 12 324 309 12 12 324 309 ..11J0 0.600 s• = ', ..15.00 17SA9 - 32 :: ' 32 :` ,473 •551. ' 32 • _ 1` 32 '. ' 473`, : ,.' 661 13A-3ocs 0.167 w 4.17 3.00 360 324 1353 971 360 324 1353 971 1A-c11ob 1.080 w 27.00 54.30 12 2 324 652 12 2 324 652 1A-c1ob 1.080 w 27.00 60.27 24 0 648 1446 24 0 648 1446 C, :. ;. '16B-lad" -:, 0 112 2.81 '-5.90.! 1875 ,,, 1875 5250 11057 ,",' 1875 `: 1875 `• 5250; 11057 F 20P70t 0:521 1,3.03 6.59 .1875 1875 .24422 , 1,2357 1875 1875 24422. 12357 61 c) AED excursion 1 3931 393 Envelope loss/gain 1 38764 32750 1 1 38764 32750 12 a) Infiltration 2610 857 2610 857 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 3 690 3 690 Appliances/other 2400 2400 Subtotal (lines 6 to 13) 41374 36697 41374 36697 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 41374 36697 41374 36697 15 Dud loads 0% 0% 0 0 -0% 0% 0 0 Total room load 41374 366971 41374 36697 Air required (dm) I I I 1669 1669 I 1669 1669 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. - - Wrlights `sfFt ' 2013-May-30 06:04:02 Rig ht-SuiteO Universal 2012 12.1.07 Right AMobile Page 1 \wstmp\a330f6l4-8lea-45cl-b37c-f4ed64gb6862.rup Calc=MJ8 FrontDoorfaces: E Job: 5437 .. eightsome Component Constructions Date: 530/2013 Entire House By: Chris Fontana All American Air and Electric 575 Nw Mercantile Place #111, Port Saint Lucie, FL 34986 Phone: 772-878-5143 Fax: 772-878-5144 Email: Jcalhoun@aaaeinc.com License: Cac057965 For: THOMAS JAY 2917 Sherwood lane, Fort Pierce, FL 34982 Phone: 772-464-0968 Msign1tion, Location: Indoor: Heating Cooling Vero Beach Municipal AP, FL, US Indoor temperature (°F) 70 75 Elevation: 23 ft Design TD (°F) 25 16 Latitude: 28°N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) -2.7 59.2 Dry bulb (°F) 45 91 Infiltration: Dailyrange (°F) - 16 ( L ) Method Simplified Wetbulb (°F) - 78 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' Btuh/ft'-°F ft'-°FBluh Btuh/ft- Btuh Btuh/ft' Btuh Walls 13A-3ocs: Blk wall, stucco ext, r-3 ext bd ins, 6" thk, 1/2" gypsum n 349 0.167 3.0 4.17 1457 3.00 1046 board int fnsh a 317 0.167 3.0 4.17 1323 3.00 950 s 299 0.167 3.0 4.17 1246 3.00 895 w 324 0.167 3.0 4.17 1353 3.00 971 all 1289 0.167 3.0 4.17 5379 3.00 3862 Partitions (none) Windows 1A-clob: 1 glazing, clr glz, mtl /w brk frm mat, 1/8" thk; 50% blinds closed, light; 50% outdoor insect screen; 2 ft overhang (2 ft window ht, 2 ft sep.) 1A-clob: 1 glazing, clr glz, mtl /w brk firm mat, 1/8" thk; 50% blinds closed, light; 50% outdoor insect screen; 2 ft overhang (3 ft window ht, 2 ft sep.) IA-c1ob: 1 glazing, clr glz, mtl /w brk frm mat, 1/8" thk; 50% blinds closed, light; 50% outdoor insect screen; 8 ft overhang (4 ft window ht, 2 ft sep.) 1A-clob: 1 glazing, clr glz, mtl /w brk frm mat, 1/8" thk; 50% blinds closed, light; 50% outdoor insect screen; 5 ft overhang (4 ft window ht, 3 ft sep.) 1A-c1ob: 1 glazing, clr glz, mtl /w brk frm mat, 1/8" thk; 50% blinds closed, light; 50% outdoor insect screen; foreground = green grass (0.23); 2 ft overhang (3 ft window ht, 1 ft sep.) IA-c1ob: 1 glazing, clr glz, mtl /w brk frm mat, 1/8" thk; 50% blinds closed, light; 50% outdoor insect screen; foreground = green grass (0.23); 2 ft overhang (4 ft window ht, 3 ft sep.) 1A-c1ob: 1 glazing, clr glz, mtl /w brk frm mat, 1/8" thk; 50% blinds closed, light; 50% outdoor insect screen; 3 ft overhang (3 ft window ht, 2 ft sep.) 1A-c1ob: 1 glazing, cir giz, mtl /w brk frm mat, 1/8" thk; 50% blinds closed, light; 50% outdoor insect screen; 2 ft overhang (6 ft window ht, 2 ft sep.) n 2 1.080 0 27.0 54 23.7 47 e 2 1.080 0 27.0 54 60.3 121 all 4 1.080 0 27.0 108 42.0 168 n 9 1.080 0 27.0 243 23.7 214 e 9 1.080 0 27.0 243 60.3 542 all 18 1.080 0 27.0 486 42.0 756 e 32 1.080 0 27.0 864 1 23.7 759 s 12 1.080 0 27.0 324 23.7 285 s 6 1.080 0 27.0 162 25.7 154 s 12 1.080 0 27.0 324 25.7 309 w 12 1.080 0 27.0 324 54.3 652 w 24 1.080 0 27.0 648 60.3 1446 Bold/italic values have been manually overridden 2013-Ma 30 06:04:03 wrl!g tso Right -Suite@ Universal 2012 12.1.07 Right J® Mobile y Page 1 \wstmp\a330f6l4-8lea-45cl-b37c-f4ed64gb6862.rup Calc=MJ8 FrontDoorfaces: E Doors 11JO: Door, mtl fbrgl type Ceilings 166-7ad: Attic ceiling, asphalt shingles roof mat, r-7 ceil ins, 1/2" gypsum board int fnsh Floors 20P-0t: Fir floor, wd fir, 1" thkns, tile flr fnsh, amb ovr s 32 0.600 6.3 15.0 473 17.5 551 1875 0.112 7.0 2.80 5250 5.90 11057 1875 0.521 0 13.0 24422 6.59 12357 Bold/italic values have been manually overridden 2013-May-30 06:04:03 ,,�°`_ft' Right-Suite®Universal 2012 12:1.07 Right J® Mobile Page 2 lwstmpNa330f6l4-8lea-45cl-b37c-f4ed649b6862.rup Calc=MJ8 FrontDoorfaces: E 6 AED Assessment Job: 537 '�`ightso'� Date: 5/3012013 Entire House By: Chris Fontana All American Air and Electric 575 Nw Mercantile Place #111, Port Saint Lucie, FL 34986 Phone: 772-878-5143 Fax: 772-878-5144 Email: Jcalhoun@aaaeinc.com License: Cac057965 For: THOMAS JAY 2917 Sherwood land, Fort Pierce, FL 34982 Phone: 772-464-096I8 Location: Vero Beach Municipal AP, FL, US Elevation: 23 ft Latitude: 28 °N Outdoor: Heating Dry bulb (°F) 45 Dailyrange (°F) - Wet bulb (°F) - Wind speed (mph) 15.0 7,00 6700 5700 4,00 3100 2,00 1,00 re Indoor: Heating Cooling Indoor temperature (°F) 70 75 Design TD (°F) 25 16 Relative humidity (%) 30 50 Cooling Moisture difference (gr/lb) -2.7 59.2 91 Infiltration: 16 (L ) 78 7.5 Hourly Glazing Load 9 1011 12 13 14 Hour of Day 15 16 17 18 19 20 / FbLdy / Aerage / PFDlimit Maximum hourly glazing load exceeds average by 38.2%. House does not have adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 393 Btuh (PFG-1.3*AFG) Bold/italic values have been manually overridden 2013-May-30 06:04:03 1d r1ght90't" Right -Suite@ Universal 2012 12.1.07 Right J@ Mobile Page 1 ...lwstmp\a330f6l4-8lea-45cl-b37c-f4ed649b6862.rup Caic=MJ8 FrontDoorfaces: E Certificate of Product Ratings AHRI Certified Reference Number: 5360116 Date: 5/30/2013 Product: Split System: Air -Cooled Condensing Unit, Coil with Blower Outdoor Unit Model Number: GSX130421B* Indoor Unit Model Number: ARUF42C14A* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade/Brand name: GOODMAN, JANITROL, AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 2101240-2008 for Unitary Air -Conditioning and Air -Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): 39500 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 * Ratings followed by an asterisk (*) Indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the products) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products ofAHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's Individual, personal and confidential reference. CERTIFICATE VERIFICATION The information forthe model cited on this certificate can be verified atwwwahridirectoryorg, A "IM' Air -Conditioning, Heating, click on'Nerify Certificate" link and entertheAHRI Certified Reference Number and the date on A. an ,' and Refrigeration Institute which the certificate was issued, which is listed above, and the Certificate No., which is listed below. 02013 Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130143971098756692