Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSDATE: FEES DUi , RECEIPT #: Permit #: Planning & Development Services Dep rtment 'S O � � . Building & Code Regulation Division Q.'`"wl.�, 2300 Virginia Avenue Ft. Pierce, FL 34982-5652 SCANNED Tel. 772-462-1553 APPLICATISEERON FOR ROOF PERMIT Lucie Count ,Y j 1. Location/Site Address: '7y62. k�i (.voo9 ✓A 2. Parcel ID Number: 3622 610 066Y or" 3 Office Use Only Section Townshi Range Map Page Zoning Land Use Initials 3. Description of Project or Work Activity: PP.aroiq44t. Lek InnO ;r sW/ �' ► � e-� 4. Total Roof Area (square feet): 3fto 5. Roof Pitch: 6. Type of Roof: ['Fiberglass Shingle [ ] Concrete Roof Tile [ ] Wood Shake / Shingle [ ] Tar & Gravel [ ] Modified Bitumen [ ] Other [ ] Product Approval required for all types of Roofing Material (2 Sets) [ ] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product Approval attached ** Roof Mitigation per F.S. 553.844 will be required. 7. Owner Information 8. Contractor Information Name: T/6k ac, 6 Address: 2�1�t°n C-4) a4 _ City: [ er State: G. 3 Zip: Phone: 9. Value of Construction: $ Z2_x F0 ,• o-n FL Reg/Cert #: C_ o?, g o � I County Cert #: A O ,56 ca Business Name: R G1n�1 I lk D r Cell Phone: -7-7P-qI -'�-le192 "Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval. CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be . done in compliance with all applicable laws regulating construction and zoning. PRINT QUALIFIERS/OWNERS NAME /bTGNATURE OF QUAUT IER/OVVNER T � L u � , " STATE OF FLORIDA, COUNTY OF - ACKNOVDLEDG S _,L Z DAY OF VVH SO N TO ME OR HAS PRODUCED AS IDENTIFICATION SIGNA ORE OF N Y TYPE OR PRINT NAME OF NOTARY (sCRESUL MIS•IYBOBILIN CMMISSICN�e�883700 c )P RRES: MAR 13, 2017 COMMISSION NUMBER O �� �J 1�-V 1nLIINUf7�1NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY E FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Revised 4/26/2010 Permit No. State of Florida County of St. Lucie NOTICE OF COMMENCEMENT / /� Tax Folio No. _% i ®Z �l O 0l1 t� y ®U 6 The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. if L � ......i n.,�...:..�:..., s o.,...e.►... l�.,a �a �r.00r aro�� ���oilohlol• I Akt woo4atk Oriel &4tiC)n &0 ok Owner information or Lessee Information if the Lessee contracted for the improvement: Name ., eCiU ` Address N72 0Z 4 Ah WQ10 -Gn If Interest in property: Ciw 4g- l Name and address of fee simple titleholder (if different from Owner listed above): Contractor's Name: Contractor Address: G Surety (if applicable, a copy of the payment bond is attached): Amount of bond Name and address: Lender Name: Phone Number: Lender's address: Phonee Number: Phone number: Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1) (a)7., Florida Statutes: Name: Phone Number: Address: In addition to himself or herself, Owner designates Lienor's Notice as provided in Section 713.13(1) (b), Florida Statutes. Phone number of person or entity designated by owner: to receive a copy of Expiration date of notice of commencement: (the expiration date may not be before the completissn of constr tion and final payment to the contractor, but will be 1 year from the date of recording unless a different date is specified) by 7-3 WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury, I declare that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of my knowledgeland beef. re ofgw'ner or Le�)ee, or Owner's or Lessee's Authorized Officer/Director/Partner/Manager OIN�� (Signatory's Title/Office) The foregoing instrument was acknowledged before me thisdary�of� 20� By e5o i4"IV pv-�-,p r M C-,� as dw vJ cc� for Name of Person Type of authority (e.g. officer, trustee) Party on behalf of whom instrument was executed ature of Notary_P-ubl' o loncla) (Print, Type, or Stamp Commissioned Name of rsonall kn or produced Identification RICHARD NEVVLAND MY COMMISSION peofIdentification produced EXPIRES: MAR 13.2017 Bonded through 1st State Insurance A O:n Ch C_ 0 rn- O ' -q rn z0�cz 7c„N0!n o p m 0 ca oC>0 bT0q M - oZ W m O o ° r 0 D —I -J � s -a m N () Property Appraiser - St.Lucie CI?»nty, FL Page 1 of 1 i PROPERTY RECORD CARD John Heddings Record: 1 of 1 <<Prev Next» Spec.Assmnt Taxes Exemptions Permits Home Print Property Identification Site Address: 7402 KENWOOD RD ParcellD: 1302-810-0064-000-3 �61�UCtEC0G2 Seclrown/Range: 02 :34S :39E Account#: 3924 f`1 Map ID: 13/02S Use Type: SF Res t Zoning: RS-4 City/Cnty: St Lucie County Ownership and Mailing Legal Description Owner: John Heddings Rachel Heddings LAKEWOOD PARK ADDITION NO 1- BLKC LOT 13 (OR 3131-1275) Address: 7402 Kenwood Rd Fort Pierce FL 34951-2412 Sales Information Assessment 2012 Total Land and Building Date Price Code Deed Book/Page 2012 Final: 110900 Land Value: 6000 Acres: 0.3 9/2/2009 112900 0112 SP 3131 / 1275 Assessed: 110900 Building Value: 104900 4/6/2009 0 0112 CT 3092 / 2348 Ag.Credit: 0 Finished Area: 2296 SgFt 6/27/2007 100 01 QC 2841 / 2085 Exempt: 50000 3/28/2006 0 01 PB 2527 / 1619 Taxable: 60900 11 /23/2004 0 01 CA 2104 / 0500 Taxes: 1426.38 7/16/1999 112000 00 WD 1238 / 1045 11/28/1995 98900 00 WD 0986 / 1498 11/1/1985 0 01 CV 0483/2503 BUILDING INFORMATION m Exterior Features View: - RoofCover: SD - Dim Shingle RoofStruct: HP - Hip ExtType: HC- -HC- YearBlt: 1986 Frame: - Grade: C- - C- EffYrBlt: 1986 PrimeWall: BS - CB Stucco StoryHght: 0010 -1 Story No.Units: 1 SecWall: Interior Features BedRooms: 3 Electric: MX - MAXIMUM PrmintWall: DW - Drywall FullBath: 2 HeatType: FHA- FrcdHotAir AvgHt/FI: 1/213ath: 1 HeatFuel: ELEC - Electric Prm.Flors: CU - Carpet %A/C: 100 %Heated: 100 %Sprinkled: 0 Special Features and Yard Items Land Information Type Y/S Qty. Units Qual. Cond. YrBlt. No. Use Type Type Measure Depth ENC2 - POOL ENC-AVG Y 1 912 AV AV 2009 1 0100-SF Res BI -Front Ft 100 131 SWAV - RES POOL AVG Y 1 288 AV AV 1996 PA01 - POOL DK-AVG Y 1 624 AV AV 1996 FNW6 - WOOD FEN 6' Y 1 240 AV AV 2000 DWC - Driv-Concret Y 1 950 AV AV 1986 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED http://www.paslc.oriz/paslc/prc.asp?prclid=130281000640003 5/20/2013 �1 Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 772-462-2165 or 772-462-2172 Fax: 772-462-6443 ROOF INSPECTION AFFIDAVIT Re: Permit # l,-11Wlicensed as a(n)Contractor*/Engineer/Architect (Ple se print name & circle license type) *F5468 Building Inspector *General, Building, Residential or Roofing Contractor or any individual certified under 468 F.S. to make such an inspection. ,p On or about , I did personally inspect the roof deck nailing ; � '— �-U �� (Date) work at: (Job site address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S.) Signature and Seal STATE OF FLO IDA COUNTY OF and subscribed before me this d` day of License # 20J3 who has produced as id e—ntitication. U Notary Public, State of Florida, Signature of Notary: Commission Number: E (Seal) En 01/19/2011 I EE 94E EEr3837pp3, 2017te Insurance Q f _ Florida Building Code Onlint�- Page 1 of 2 I --77 3'rvA*^^;*f°�'ydLw.,}Y, Cri.3;; 1i�v�l'"�:c,^.� C� BCIS Home Log In User Registration :Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links search Business's *' Product Approval P rofessi•nal 7 USER: Public User Re u o)n Pioduct Approval Menu > Product or Application Search > Application List > Application WA. FL # FL10674-R6 Application Type Revision �r Code Version 2010 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Owens Corning One Owens Corning Pal Toledo, OH 43659 (740)404-7829 greg. keeler@ owenscorr Greg Keeler greg.keeler@owenscorn,,.y.,.,,. Mel Sancrant 1 Owens Corning PKWY Toledo, OH 43659 (419)376-8360 mel.sancrant@owenscornig.com Roofing Asphalt Shingles Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 5D Evaluation Report - Hardcopy Received Robert J.M. Nieminen PE-59166 Underwriters Laboratories Inc. 09/26/2014 John W. Knezevich, PE D' Validation Checklist - Hardcopy Received FL10674 R6 COI Trinity ERD CI - Nierninen.pdf Standard Year ASTM D3161, Class F 2006 ASTM D3462 2007 ASTM D7158, Class H 2O07 http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5V%2... 6/ 15/2012 r Florida Building Code OnlinL Page 2 of 2 Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 02/16/2012 02/21/2012 02/24/2012 04/03/2012 IFL # _______7 Model. Number iDescription i10674.1 Owens Corning Asphalt Roofing 3-tab, laminated, starter, and hip & ridge Shingles and Starters Limits of Use Installation Instructions Approved for use in HVHZ: No FL10674 R6 II er020612FINAL OC FL10674- R6 Asohalt Shinoles.Ddf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert J. M. Nieminen PE - 59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to ER, Section 5. Evaluation Reports FL1.0674 R6 AE er020612FINAL OC FL10674- R6 Asphalt Shinoles.pdf Created by Independent Third Party: Yes ------ -. --- ----- Back 1 Next Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, e-mail addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions regarding DBPR's ADA web accessibility, please contact our Web Master at webmaster@dbpr.state.fl.us. Product Approval Accepts: aq Norton rntrity ti a;ctt http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param--wGEVXQwtDgtBNbEY5V`/o2... 6/ 15/2012 f EXTERIOR RESEARCH & DESIGN, LLC. 1 Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 -f�INITYIIERD OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12 One Owens Corning Parkway FL10674-R6 Toledo, OH 43659 Date of Issuance: 02/06/2012 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2010 FBC and 2010 FBC Residential Volume sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 02/06/2012 This does not serve as an electronically signed document. Signed, sealed hardcopies have been w•�Jii. N al«y'' transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. TrinitylERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. \-JTRINITY 1 E D ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2007 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161, Class F 2006 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158, Class H 2O07 3. REFERENCES: Entity Examination Reference Date UL (CER1739) Physicals & Wind Resistance File R2453, Vol. 3 02/15/2007 UL (TST1740) Physical Properties 06CA20263 04/18/2006 Miami -Dade (CER1592) FBC HVHZ Compliance 07-1116.12 02/14/2008 Miami -Dade (CER1592) FBC HVHZ Compliance 09-0915.12 12/16/2009 Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.09 10/27/2010 Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.10 10/27/2010 Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.08 10/27/2010 Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.07 10/27/2010 Miami -Dade (CER1592) FBC HVHZ Compliance 11-0411.03 06/16/2011 Miami -Dade (CER1592) FBC HVHZ Compliance 11-0919.05 10/13/2011 UL (QUA1743) Quality Control Service Confirmation Exp. 09/26/2014 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic° and Supreme° are fiberglass reinforced, 3-tab asphalt roof shingles. 4.1.2 Berkshire® are fiberglass reinforced, 4-tab asphalt roof shingles. 4.1.3 Duration°, Duration° Premium, Oakridge° and WeatherGuard° HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Berkshire° Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant and WeatherGuard° HP Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.3 Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ. 5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.3 Wind Classification: 5.3.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for us in all wind zones up to Vasd = 150 mph (V,it = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. Exterior Research and Design, LLC. Evaluation Report 037940.02.12 Certificate of Authorization #9503 FL10674-R6 Date of Issuance: 02/06/2012 Page 2of6 i \, l ERD 5.3.2 All Owens Corning hip & ridge shingles and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for us in all wind zones up to Vasd = 150 mph (V„it = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.3.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.3.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.4 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 9N-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 9N-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: ➢ Berkshire° shingles require minimum five (5) nails per shingle. ➢ WeatherGuard® HP shingles require minimum six (6) nails per shingle. ➢ Starter Strip Plus requires minimum five (5) nails per strip. Refer to Owens Corning published information on wind .resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. 6.2.5 Minimum Nailing — Classic® & Supreme: Normal Mansard or Area pare Wind Areas High Wind dosvenes y Area pare vientos normal-e-s� Areas vientos fuertes r+'+�, ..tat,. +�•.--aM i, z• �tal� r2" +", 5'Exposure Exposicidn Exterior Research and Design, LLC. Certificate of Authorization #9503 Normal Mansard or Area pare Wind Areas High Wind desvanes y Area per,* vientos normales Areas viontas fuerres 8 WO' Exposure Exposiaidn Evaluation Report 037940.02.12 FL10674-R6 Date of Issuance: 02/06/2012 Page 3 of 6 6.2.6 Minimum Nailing - Berkshire®: Sealant strip / La lira de sellador -> i s�----►C • 4 • '8Vt' 8Vt' I 8VT I s vt� T. 6.2.7 Minimum Nailing - Duration® & Duration® Premium: 6.2.8 Minimum Nailing - Oakridge®: 4 Nail Pattern Esquama con 4 davos Imo-- tz' ---►I IF 12. —>I 6 518" Exposure Nails 66/8"Exposure Exposlef6adoF6/8pulg. clavos Exposicionde66/8puig. J TRINITY: ERD Sealant strip La fire de sellador a W" It I 8 W, I 8111, I 8 Yf t Asphalt roofing cement Cemeato de Who de okfto Nansaraand Steep SIODe 6 Noll tMn aetween Suanaa® Pattern ainandtoe al N1 o1e. Esquema — O-W, cpaMiadae de6clavos agt 00daenhee+ • • • ereaSweNalD rbparfe s�adarcn¢au. StireaaiP SureMairo hsterin99 tasienhAA areamidtA areavhtlth Arcade t" �T Areada LE 5%" Exposure Nails 5W Exposure xposkffin 5%jaufg. de eClavos 51h pufg. de exposition 6 Nail Pattern Esquema con 6 clavos r r 5 518" Exposure clavios 5 518" Exposum Fxposisidn de 6Vg pulg. Exposictdn de 5 518pidg. Exterior Research and Design, LLC. Evaluation Report 037940.02.12 Certificate of Authorization #9503 FL10674-116 Date of Issuance: 02/06/2012 Page 4 of 6 6.2.9 Minimum Nailing — WeatherGuard® HP: Single Side View 6.3 Hip & Ridge Shingles: a .,fi 3 E R 6.3.1 Installation of Berkshire° Hip and Ridge Shingles, High Ridge, Hip & Ridge with Sealant and WeatherGuard° HP Hip and Ridge Shingles shall comply with the manufacturer's current published instructions, using four (4) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand -sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing — Berkshire® Hip & Ridge and High Ridge:, Fig. 1 4 .�— PrevailingWind Direction \ A Nails * \ A I I A I I A I 4 I I I I I V Exposure 6.3.4 Minimum Nailing — Hip & Ridge with Sealant: tilem Fig. 2 - High Wind Fastening Paittem (4 Nails) rim Shingle and Discard 2„E32-PE1cCass l,r1„SealantStrip T'12" 'Fastening S1/R' Distance 12" Exterior Research and Design, LLC. Certificate of Authorization #9503 Fig. 2 Top View Side View Nails Nails 2 Top Laminated 4" Piece • 1" i D" I i =1 JI �I u� I I I I" I I I 72 ry Evaluation Report 037940.02.12 FL10674-116 Date of Issuance: 02/06/2012 Page 5 of 6 6.3.5 Minimum Nailing — WeatherGuard® HP Hip and Ridge: Fig. A q q prevailing Wind �- DlrediDn A A Nails � I I A I I \ n I I q I I \ I I A I I I I I I I I Exposum 7. LABELING: I Fig. C Hip & Ridge Shingle Fastening TopVlew Nails Nails r 2" 2" 1 �• F. Exposure I 17 •I 7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. S. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: Underwriters Laboratories — QUA1743; (414) 248-6409; karen.buchmannOul.com - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report 037940.02.12 Certificate of Authorization #9503 FL10674-116 Date of Issuance: 02/06/2012 Page 6 of 6 Florida Building Code GnlirL Page 1 of) FL # FL6785-R4 Application Type Editorial Change Code Version 2010. Application Status Pending FBC Approval Comments Archived Product Manufacturer Carlisle Coatings & Waterproofing Address/Phone/Email 900 Hensley lane -' Wylie, TX 75098 (717) 245-7000 Ext 7456 spy wert@syntec.carilsie.com + Authorized Signature Chad Wert wert@syntec.carlisle.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underiayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who Robert Nieminen developed the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 02/20/2013 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of independence FL67t35 i2_CC3t 7r3nity rRD CI_= A3iemn-n.pdf Referenced Standard and Year (of Standard) Standard Year ASTM D1970 2001 Equivalence of Product Standards Certified By Sections from the Code littp ://www..floridabui lding.org!pr/pr_app_dtl. aspx?param=wGEVXQwtDgvkdyKrmfaLgB... 5/22/2012 Florida Building Code Onli0 % Page 2 of Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Isummary of Products Method 1 Option D 04/11/2012 04/25/2012 04/28/2012 FL # Model, Number or Name Description 6785.1 1CCW Roof underlaymentsSelf-Adhesive Roofing Underlayment limits of Use Installation Instructions Approved for use in HVHZ: No EL678S,._R4 11 !L- 4191.2FINAl;CAKLISLE UNDi-Rt.AYMEhTS 1`1_678S: Approved for use outside HVHZ: Yes R4.odf Impact Resistant: N/A ;i Design Pressure: N/A ; Other: 1.) Refer to ER Section 5 for �.Limits of Use 2.) Refer to ER Section 6 for =Installation. Verified 8y: Robert Nleminen 59166 Created by Independent Third Party: Yes I Evaluation Reports I FL�S R4 AE er841 12t 7NAL CARLTSI..E UNDERtAYMENTS _FL 78 - i .Created by Independent Third Party: -Yes 1:7� next `l Correct Us :; 1940 North Wnroe street Tallahassee FL 32399 Phone: 8%4_67-t-tom The Slate of Florida is an AAJE[O employer, Cunvroht 70()7-2010 State o' Florida :; privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, e-mali addresses are public records. If you do not went your e-mail address released in response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions regarding DBMS ADA web accessibility, please contact our Web Master at webmastercadbpr.state.Fl.us, Prrto��duct Approval Accepts: http://wurw.floridabuilding.orglprlpr_app_dtl.aspx?param=NvGEVXQwtDgvkdyKrmfaLgB... 5/22/201.2 ,' EXTERIOR RESEARCH & DESIGN, LLC. Certiflcate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT Carlisle Coatings & Waterproofing Evaluation Report C39180.12.11-R1 900 Hensley Lane FL6785-R4 Wylie, TX 75098 Date of Issuance: 12/09/2011 Revision 1: 04/22/2012 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2010 Florida Building Code sections noted herein. LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity]ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinityl ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 4. Prepared by: Robert 1M. Nieminen, P.E. Florida Registration No. 59166, Florida Dt A ANE1983 �= The facsimile seal appearing was authorized "" by Robert Nieminen, P.E. on 04J22/2012 This does not serve as an electronically signed ' document. Signed , sealed hardrnpies have been 'transmitted • .`'�l�.a i,t�*,•'� to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. TrinitylERD is not owned, operated or controlled by any company marillfaJUnrig or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial Interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, F.E. does not have, nor will acquire, a financial interest in any Other entity involved in the approval process of the product, 2,y�a-0ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category. Roofing Sub -Category: Underlayment Compliance Statement: CCW Roof Underlayments, as produced by Carlisle Coatings & Waterproofing, have demonstrated compliance with the following sections of the Florida Building Code through testing In accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.4, 1507.2.9.2, Physical Properties ASTM D1970 2001 1507.5.3 3. REFERENCES: Entity Examination deference Date MTI (T5T2508) Physical Properties PX02MOA 01/17/2011 MTI (TST2508) Physical Properties PXI6MOA 01/18/2011 MTI (TST2508) Physical Properties PX13MOB 01/18/2011 M-D (CER1592) HVHZ Compliance 09-0630.13 08/12/2009 ICC-ES (EVL2396) 2006 IBC Compliance ESR-1556 08/01/2007 UL, LLC. (QUA9625) Quality Control Inspection Report, R18678 02/20/2012 4. PRODUCT DESCRIPTION: 4.1 CCW WIP 100 is a self -adhering, fiberglass reinforced, granule surfaced, rubberized asphalt roof underlayment. 4.2 CCW WIP 250 is a self -adhering, fiberglass reinforced, film surfaced, rubberized asphalt roof underlayment. S. LIMITATIONS: 5,1 This Evaluation Report is not for use in the HVHZ. 5.2 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.3 CCW Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the AHJ for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.4 Allowable roof covers applied atop the underlayments are follows: Table 1, Roof Cover Options - Asphalt Asphalt foam -on -1Nood slate & f Underlayment Shing` Nail -On Tile I� Tile metal Shakes & Synthetic _ _ _ 1 Shingles Slate/Shake CCw WIP 100 Yes No No No T No No CCw WIP 250 Yes No + No Yes No I No Exterior Research and Design, LLC. Certificate of Authorization #9503 Evaluation Report C39180.12.11-Ri FL6785-R4 Revision 1: 04/19/2012 Page 2 of 4 5.5 Allowable substrates are noted below: 5.5.1 Direct-BOnd t0 Deck: Self -adhering membranes applied to: New untreated plywood; :* Primed new untreated plywood; • Existing plywood; • Primed existing plywood; Note: While not required, CCW-702 or CAV-GRIP printer may be used when deemed appropriate or when temperatures are below 400F. 5.5.2 Bond to Mechanically Attachgd .l3a$ [_ayer: Self -adhering membranes applied to: > ASTM D226, Type I or II felt; For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. 5.6 Exposure Limitations: 5.6.1 CCW WIP 100 and CCW WIP 250 shall not be left exposed for longer than 30-days after installation. 6.1 CCW Roof Underlayments shall be installed in accordance with Carlisle Coatings & Waterproofing published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application. Prime the substrate (if applicable) with CCW-702 or CAV-GRIP Primer. 6.3 CCW WIP 100 and CCW WIP 259 6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.3.2 While not required, CCW-702 or CAV-GRIP primer may be used when deemed appropriate, Priming is required when temperatures are below 40cF. 6.3.3 Cut WIP roofing underlayment into 10 to 15 ft lengths. Remove 2 to 3 ft of release film and align the edge of the membrane, sticky -side down, so it overhangs the drip edge by 3/8-inch. Continue to remove release film and press as you move across the roof. Use a hand roller and/or hand pressure to press into place. 6.3.4 Horizontal seams should be minimum 3.5-inches, configured to shed water. Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in the course below. 6.35 Consult Carlisle Coatings & Waterproofing for steep slope & back nailing requirements. 6.3.6 For Valleys and Ridges: taut WIP 100 roofing underlayment into manageable lengths. Align over the center of the valley, hip or ridge, Remove release film. Press the middle of the membrane first before working toward the edges. For open valleys, cover roofing underlayment with metal valley liners, Exterior Research and design, LLC. Certificate of Authorization #9503 Evaluation Report C39180.12.11-Ri F11-6765-114 Revision 1: 04/19/2012 Page 3 of 4 W TRINITY! ERD 7. LABELING: Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the manufacturer or the named. QA entity for plants covered under Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL, LLC- QUA9625; (847) 664-3281 - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report C39180.12.11-RI Certificate of Authorization #9503 FL6785-114 Revision 1: 04119/2012 Page 4 of 4