HomeMy WebLinkAboutSUBMITTED PAPERSDATE: FEES Dt /JkA RECEIPT #: Permit #:
Planning & Development Services Department
/3Qs -6aT?
Building & Code Regulation Division SC
2300 Virginia Avenue gNNE
Ft. Pierce, FL 34982-5652 S' Q
Tel. 772462-1553 f � t/Cie C
APPLICATIION FOR ROOF PERMITSEE REVERSE SIDE FA otnty
UCTIONS
1. Location/Site Address: � '� Iyd 1c l Ll ye
—
2. Parcel ID Number: 1 ?)01 - (� 05 - Q�) 9' C? - (Y)U ^ ')
Office Use
Only
Section
Townshi
Range
Map Page
Zonin'
Land Use
Initials
3. Description of Project or Work Activity: 'FC0.1' C?:' k e �6� Cs0•
4. Total Roof Area (square feet): ) '9O b 5. Roof Pitch:
6. Type of Roof: [ ] Fiberglass Shingle [ ] Concrete Roof Tile [ ] Wood Shake / Shingle
[ ] Tar & Gravel [ ] Modified Bitumen W Other
[� Product Approval required for all types of Roofing Material (2 Sets)
] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product
Approval attached -
** Roof Mitigation per F.S. 553.844 will be required.
7. Owner Information 8. Contractor Information
Name: i!e 4 n 12 mlcp kq
Address: B0,10 '3 71�)e cLr\ CL
City: "yn- - Qi Q.CU State: L
Zip: Aacft Phone: 77 a - 5.1e- D5a5
FL Reg/Cent #: Cee. o 5R aQ 1
County Cert #: 90,66(,
Business Name: K,i Ck e- &ham
Cell Phone: 7`7Q/%73 -&/9 7
9. Value of Construction: $ 9, �C Q -
"Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval.
CONTRACTORIOWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be
done in compliance with all applicable laws regulating construction and zoning.
tar d
PRINT QUALIFIERS/OWNERS NAME SIGNATURE OF QUAi_iFHMO R
STATE OF FLORIDA, COUNTY OF .t. C�
ACKNOWLEDGED BEFORE ME THIS 1 DAY OF 20 i , BY 0,J--,G C%
WHO IS PERSONALLY KNOWN TO ME OR HAS PRODUCED AS IDENTIFICATION
s-.Lt Y) BOBILIN
SIGN RE OF Y TYPE OR PRINT NAME OF NOTARY (seal) r�tn W COMMISSION EE883700
COMMISSION NUMBER EXPIRES: MAR 13, 2017
7�
Bonded through 1st State Insurance
NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE
FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
Revised 4/26/2010
Permit No.
State of Florida County of St. Lucie
NOTICE OF COMMENCEMENT
Tax Folio
The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes,
the following information is provided in this Notice of Commencement.
O` Pi�rCo L 3LCj5
3 D��a.r, a Owe
Legal Description of Property: (and street address if available):
,LQaCP�_ �1C — L� n; -ll- --5 - ). f_ fS (.9 Lbf eg ) (m� )S.J^g,5) (or ] O ?1- l y 1 )�
General description of improvement -Teo- - C?PP . ep fop-C W44-'1 M-e-4-a l�
Owner information or Lessee information if the Lessee contracted for the improvement:
Name t4n alNkposr-, P rnf a C-ONu
Address 8,'I-,0"`X�o2.\CA-r16- Ave, T �- f-�i QX-csz
Interest in property: nIiyn 'PX-
Name and address of fee simple titleholder (if different from Owner listed above):
Contractor's Name:
Contractor Address:
Surety (if applicable, a copy of the payment bond is attached): Amount of bond: $
Name and address:
C Phone Number:
hone number:
Lender Name: Phone Number:
Lender's address:
Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Sectio
713.13(1) (a)7., Florida Statutes:
Name: Phone Number:
Address:
In addition to himself or herself, Owner designates of
Lienor's Notice as provided in Section 713.13(1) (b), Florida Statutes.
Phone number of person or entity designated by owner:
to receive a copy of
Expiration date of notice of commencement: (the expiration date may not be before the comp etio of const onApodfifigaI yment tc
contractor, but will be 1 year from the date of recording unless a different date is specified) 19� A _ C7iCJ P�
T�
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED
IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR
RECORDING YOUR NOTICE OF COMMENCEMENT.
rr ,XF(hO
OzmZm
s"wC
G} 6 n n
Nmus
pis
QG) C?
nt c3 Z
-4 r=
rn
c) o �.
Ja O
ct in 1
°i i
=a m
Under penalty of perjury, I declare that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of
my knowledge and_k ief. _
of Owner d—rLessee, or Owner's or Lessee's Authorized Officer/Director/Partner/Manager
(Signatory's Title/Office)
The foregoing instrument was acknowledged before me this day of , 20_ ,
By ��J1�1 V_ as �9 LJh fif for
Name of Person Type of authority (e.g. officer, trustee) Party on behalf of whom instrument was executed
(Signat)ure of N'o ry Public - State of Florida)
(P nt, T e, or Wylg6j&ted Nat ie of Notary -Public)
'n
MY COMMISSION #EE883700
EXPIRES: MAR 13, 2017
CP Bonded ttUOugh 1st State Insurance
Personally known=�ror produced Identification
Type of Identification produced
Property Appraiser - St.Lucie Caw¢ Jity, FL
Page 1 of 1
Kathleen P Murphy
Record: 1 of 1
Property Identification
Site Address:
8303 Deland Ave
Sec/Town/Range:
02 :34S :39E
Map ID:
13/02S
Zoning:
RS-4
Ownership and Mailing
Owner: Kathleen P Murphy
Address: 8303 Deland Ave
Fort Pierce FL 34951-1387
Sales Information
Date Price Code Deed
4/2/1997 5000 00 WD
PROPERTY RECORD CARD
«Prey Next» Spec.Assmnt Taxes Exemptions Permits Home Print
ParcellD: 1301-605-0399-000-7 �V�Ci�G
Account #: 1409
Use Type: SF Res
City/Cnty: St Lucie County
-
Legal Description
LAKEWOOD PARK -UNIT 5- BLK 56 LOT21 (MAP 13/02S) (OR 1071-
1411)
Assessment 2012
Book/Page 2012 Final:
59800
1071/1411 Assessed:
59800
Ag.Credit:
0
Exempt:
34800
Taxable:
25000
Taxes:
581.93
BUILDING INFORMATION
Total Land and Building
Land Value: 5500 Acres: 0.28
Building Value: 54300
Finished Area: 1192 SgFt
Exterior Features
View:
-
RoofCover:
FS - Fibrgiss Shg
RoofStruct:
HP - Hip
ExtType:
HC- - HC-
YearBlt:
1997
Frame:
-
Grade:
C- - C-
EffYrBlt:
1997
PnmeWall:
BS - CB Stucco
StoryHght:
0010 -1 Story
No.Units:
1
SecWall:
-
Interior Features
BedRooms:
3
Electric:
MX - MAXIMUM
PrmintWall:
DW - Drywall
FuilBath:
2
HeatType:
FHA - FrcdHotAir
AvgHUFI:
1/213ath:
0
HeatFuel:
ELEC - Electric
Prm.Flors:
CU - Carpet
%A/C:
100
%Heated:
100
%Sprinkled:
0
Special Features and
Yard Items
Land Information
Type
Y/S Qty. Units
Qual. Cond.
YrBlt. No. Use Type
Type
Measure Depth
DWC - Driv-Concret
Y 1 760
AV AV
1997 1 0100-SF Res
BI -Front Ft
90 134
THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED.
http://www.paslc.org/paslc/Prc.asp?prclid=130160503990007 4/24/2013
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34982
772-462-2165 or 772-462-2172
Fax: 772=462-6443
ROOF INSPECTION AFFIDAVIT
t
Re: Permit #
I, t( /I , licensed as a(n)Contractor*/Engineer/Architect
(Please print name & circle license type) *FS468 Building Inspector
*General, Building, Residential or Roofing Contractor or any individual certified under 468 F.S. to make such an inspection.
On or about Y 2'6' ' 3 ,1 did personally inspect the roof deck nailing
Q(Date) /
work at: CJ 3 o 3 , a <�rr dv o eE • ,,y
(Job site address)
Based upon that examination I have determined the installation was done according to the Hurricane
Mitigation Retrofit Manual (Based on 553.844 F.S.)
Signature and Seal License #
STATE OF FLORIDA
COUNTY OF sN_I, ja..e_0
Sworn to and subscribed before me this 2-0 day of //"17Q/'e- 20—/--7
by f.°iGC�ar� /i1[�' �tio is pe v nown a or who has produced
as identification.
Notary Public, State of Florida
Signature of Notary:
Commission Number: (Seal)
En 01/19/2011
9AMISTYSMILIN
NE883700
2017
insurance
REVISIONS
BUILDING ROOF LAYOUT
SCALE: N.T.B.
ROOFZONES
SCALE: N.T.S.
COMPONENT & CLADDING DESIGN PRESSURES:
ROOF
LOCATION
ACTUAL
ALLOWABLE
ZONE 1
FIELD
-30.1 PSF
-108.5 PSF
ZONE 2
PERIMETER
-62.4 PSF
-108.5 PSF
ZONE 3
CORNERS
-98.0 PSF
-108.5 PSF
WOOD DECKING:
15/32" (MIN.) PLYWOOD OR WOOD PLANKING @ 24" O.C. SPANS ATTACHED WITH 8d RING
SHANK NAILS OR #8 X 2" SCREWS @ 8" O.C. MAX. IN THE FIELD & 8" O.C. MAX. AT THE
PERIMETER.
CALCULATIONS BASED ON THE ROOFING APP. STANDARD (RAS117)
5 V METAL CRIMP ROOFING ATTACHMENT:
#9-15 X 1-1/2" WOODZAC W/ ZAC HEAD HEAD S.S. OR GALV. WOOD SCREW W/ SELF
SEALING WASHER AT MAX. SPACING OF 12" O.C. @ THE CORNERS & 12" O.C.
THROUGHOUT (BASED ON FLORIDA PRODUCT APPROVAL #FL11651.12).
ZONE 1:
ALLOW. UPLIFT = -108.5 PSF > ACTUAL = -30.1 PSF
ZONE 2:
ALLOW. UPLIFT = -108.5 PSF > ACTUAL = -62.4 PSF
ZONE 3:
ALLOW. UPLIFT = -108.5 PSF > ACTUAL = -98.0 PSF
NOTES:
1. ROOFING OVER EXISTING WOOD DECK.
2. INSTALL FASTENERS PER REQUIRED
FREQUENCY LISTED ABOVE FOR WOOD
DECKING & ROOF COVER.
3. FOLLOW ALL LOCAL & REGIONAL
ORDINANCES.
4. USE FASTENERS AS PER REQUIRED
MANUFACTURERS SPECIFICATIONS & FL#
11651.12.
5. ALL DIMENSIONS ARE TO BE VERIFIED BY
CONTRACTOR.
DESIGN CRITERIA: 0
2010 FBC
ASCE 7-10
WIND LOAD: 160 MPHjV81tk '
124 MPH%V9&)9 ;
WIND BORNE DEBRISSF
MEAN ROOF HEIGHT: < %•.,
HIP ROOF CONDITION.
ENCLOSED BLDG.
BLDG CATEGORY II
EXPOSURE: "C"
ADJUSTMENT FACTOR: 1.21
GCPI: +/- 0.18
END ZONE (A): 4.0'
�" Rim
�8G8
8
Hu
W0 g
h
� ° I
W duo
oqw ?fill/
scn�
AS SHOWN
SHEET
S-1
,Florida Building Code Online ,
l
1
rtigu I V1 -✓
3 "``- kr 3 --�+ r 4sh f'3' 5 rl�,"w �'-- .ol.
TMI
BaS Home i LogIn(User Registration f Hot Topics Submit Surcharge i Stats & Facts Publications(FBG Staff ;Bus Site map' unks 1 Search
Business' Product Approval
Professional b, USER: Public User
Regulation
Product Aporoval Menu > Product or Aoolication Search > Aoolication List> Application Detail
fir, FL #
g °32 6, 1ra Application Type
Code version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who
developed the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
FL11651-RI
Revision
2010
Approved
Di
Gulf Coast Supply & Manufacturing, LLC.
4020 S. W. 449th Street
Horseshoe Beach, FL 32648
(352) 498-7852 I com
ray@gulfcoastsupp Y-
Ray Bowen
ray@gulfcoaStsupply.com
Roofing
Metal Roofing
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
ill Evaluation Report - Hardcopy Received
Terrence E. Wolfe
PE-44923
Keystone Certifications, Inc.
04/12/2014
Locke Bowden
=1 Validation Checklist - Hardcopy Received
FL11651 R1 COi Letter of Certif.PcIff
odf
FL11651 Ri COI Letter of Name chande.
Standard and Year (of Standard) Standard
Year
Year
Referenced
FM 4471
t995
2010
FM 4471
1995 1995
TAS 100
2003
TAS 125
4
200200
UL 1897
UL 580
Equivalence of Product Standards
GEVXQwtDgsQFcSK%2fTr... 4/29/2013
http.//www.floridabuilding.org/pr/pr_app dtl.aspx?param=w
Florida Building Code Online
Yes
Mechanical Lock
.imits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/_-123.5PSF
Other: -59.75 psf @ 24" O.C. clip spacing. -123.5 psf @
6" o.c. clip spacing. Install per manufacturers detals. For
use in HVHZ Zones.
.imits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-116.OPSF
other: -86.0 psf @ 24" o.c. dip spacing. -108.5 psf @
12" O.C. clips spacing. -116.0 psf @ 6" o.c. clips spacing.
details. For use in HVHZ Zones
Ga. Gulf Coast Mechanical
.1mits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-108.5PSF
Other: -71.0 psf @ 24" o.c_ clip spacing. -108.5 psf @
12" o.c. clip spacing. Install per manufacturers details.
Not for use in HVHZ Zones.
Ga. Gulf Lok
.1mits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-96.7PSF
Other: -81.75 psf @ 10-1/4" o.c. fastener spacing. -
96.76 psf @ 5-1/8" o.c. fastener spacing. Install per
... -farh lrers details. Not for use in HVHZ Zones.
Ga. Gulf Seam
Mechanical Lock 24 Ga. 16" Wide Roof Panel over
Installation Instructions
FL11651 R1 II 24 aa.Mech Lock over .5
31ywood HVHZ details.pdf
Verified By: Terrence E. Wolfe, P.E. 44923
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 Ri AE 1.5 Mech Lock 24 aa. over 5 Plywood
(HVHZ Roof 2010 format.odf
r_�.,.......fanf• Third PartV: Yes
.imits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-93.5PSF
Other: -93.5 psf @ 18" o.c. Install per manufacturers
details. Not for use in HVHZ Zones.
ii 24 Ga. Gulf Seam
5" Snap Lock 24 Ga. Roor ranef uv---
:nstallation Instructions
FL11651 Rl II 1 5 in Snap Lock 24 Ga. details, df
Verified By: Terrence E. Wolfe, P.E. 44923
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R1 AE 1.5 Snap Lock 24 ga. over .5 plywood
i Party: Yes
Ga. Gulf Coast Mechanical Seam 18" Wide over
Instructions
Verified By: Terrence E. Wolfe, P.E. 44923
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 RI AE 2 Mech Lock 24 a. over .5 PI wood
)4 Ga Gulf Lok 16" Wide over 151s4 rlr..-
[nstallation Instructions
FL11651 RI II 24 Ga Gulf Lock over 5 Plywood
1�1onHVHZ Details.odf
Wolfe,Verified By: Terrence E-
Created by Independent Third Party: es3
Evaluation Reports
FL11651 R1 AE 24 oa. Gulf lock over 15-32 plywood
.1mits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant, N/A 108.5PSF
Design Pressure: +N/A/-
Other: -69.25 psf @ 24" o.c. clip spacing. -108.5 psf @
12" o.c. clip spacing. Install per manufacturers details.
Not for use in HVHZ Zones.
z Created
Gulf Seam 16 eWide'Roof Panel over ix4 Wood
Purlins over 15/32" Plywood
Installation Instructions
FL11651 Ri II 24 Ga. 1.75 Gulf Seam over Sx4
details.pdf
Verified By: Terrence E. Wolfe, P.E. 44923
Created by Independent Third Party: Yes
Evaluation Reports nvPr lx4 ourlins
FL11651 R1 AE Guif Seam 24 Qa
L1651 _�26 Ga SV cramp
.imits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-156.5PSF 156.5
Other: -108.5 psf @ IT, o.c. fastener spacing. -
psf @ 6" O.C. fastener spacing. Install per manufacturers
-ated by Independent Third Party: es
Ga. Gulf Seam, 13/4' Snap Lock, 18 Wide Roof
Installation Instructions
FL11651 R1 II 24 Ga. Gulf Seam over. 5 Non HVHZ
)CLdlll�-P--
Verified By: Terrence E. Wolfe, P.E. 44923
Created by Independent Third Party: Yes
:valuation Reports , 1, _
Third
�6 Ga 5V Lrimp fcuul--
:nstallation Instructions
FL11651 RI II 26 Ga. 5V Crim over .5 plywood
iVHZdetails.pdf
P.E. 4492
Verified by:i dependentThirdnce E- ,party: es3
Created by
Evaluation Reports _ _ er s pivwooi
http://www.floridabuilding-org/pr/pr_app--4tl.aspx?paraD'=wGEVXQvgSQcSK%2fTr... 4/29/2013
F
FL# 11651.13 R1
Force Engineering & Testing Inc.
19530 Ramblewood Drive
Humble,TX 77338
Product Evaluation Report
GULF COAST SUPPLY & MANUFACTURING, LLC.
26 Ga. 5V Crimp Roof Panel over 15/32" Plywood
Florida Product Approval # 11651.13 111
Florida Building Code 2010
Per Rule 9N-3
Method: I —D
Category: Roofing
Subcategory: Metal Roofing
Compliance Method: 9N-3.005(1)(d)
NON HVHZ
Product Manufacturer:
GULF COAST SUPPLY & MANUFACTURING, I.I.C.
4020 S.W. 440h Street
Horseshoe Beach, Florida 32648
Engineer Evaluator:
Terrence E. Wolfe, P.E. # 44923
Florida Evaluation ANE ID:1920
Validator-
Locke Bowden, P.E., FL #49704
9450 Alysbury Place
Montgomery, AL 36117
Contents:
Evaluation Report Pages 1-4
C E. E +z• ��i
c
F �
No. 41
a • STATE OF
��ipa`• F�ORI�p`, �w�
sm.orabm+ �i FS • . •(�'�. ���
rune I*i; p +AEfi
�t;
FebruaryL1, 2012
rForceEngineering & Testing Inc.
19530 Ramblewood Drive
Humble,TX 77338
Design Procedure: Based on the dimensions of the structure, appropriate wind loads are
determined using Chapter 16 of the Florida Building Code 2010 for roof cladding
wind loads. These component wind loads for roof cladding are compared to the
allowable pressure listed above. The design professional shall select the
appropriate erection details to reference in his drawings for proper fastener
attachment to his structure and analyze the panel fasteners for pullout and
pullover. Support framing must be in compliance with Florida Building Code 2010
Chapter 22 for steel, Chapter 23 for wood and Chapter 16 for structural loading.
% N C E. g•
V 1 C E N
% ':e s
No. 474
1 •a • STATE OF ; a
p s a OIN AL t 1" � A�
FL# 11651.13 RI February 22, 2012
:Force Engineering &I Testing Inc.
19530 Ramblewood Drive
Humble,TX 77338
Code Compliance: The product described herein has demonstrated compliance with
The Florida Building Code 2010, Section 1504.3.2.
Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load
requirements of the Florida Building Code 2010, as relates to Rule 9N-3.
Performance Standards: The product described herein has demonstrated compliance with:
■ UL 580-06 - Test for Uplift Resistance of Roof Assemblies
■ UL 1897-04 - Uplift Test for Roof Covering Systems
Reference Data: 1. UL 580-94 / 1897-98 Uplift Test
Force Engineering & Testing, Inc. (FBC Organization # TST-5328)
Report No.117-0053T-05 & 117-0331T-08
2. Certificate of Independence
By Terrence E. Wolfe, P.E. (No. 44923) @ Force Engineering & Testing, Inc.
(FBC Organization # ANE ID: 1920)
Test Standard Equivalency: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard.
2. The UL 1897-98 test standard is equivalent to the UL 1897-04 test standard.
Quality Assurance Entity: The manufacturer has established compliance of roof panel products in
accordance with the Florida Building Code and Rule 9N-3.005 (3) for
manufacturing under a quality assurance program audited by an approved
quality assurance entity.
Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2010, including Section
1507.4.2 and in accordance with Manufacturers recommendations. For slopes
less than 3:12, lap sealant must be used in the panel side laps.
Installation: Install per manufacturer's recommended details.
Underlayment: Per Manufacturer's installation guidelines per Florida Building Code 2010 Section
1507.4.5.
Roof Panel Fire Classification: Fire classification is not part of this acceptance.
Shear Diaphragm: Shear diaphragm values are outside the scope of this report.
1/11��I
• No. 449�
• .a • STATE OF : ae
FL# 11651.13 R1 February 22, 2012
U Force Engineering & Testing Inc.
19530 Ramblewood Drive
Humble,TX 77338
Compliance Statement:
The product as described in this report has demonstrated compliance with the
Florida Building Code 2010, Sections 1504.3.2.
Product Description:
5V Crimp Roof Panel, 26 Ga. Steel, 24" coverage, through fastened roof panel
with fasteners in the panel flat over Min. 15/32" Plywood decking. Non -
Structural Application.
Panel Material/Standards:
Material: Min. 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to
Paint finish optional
Florida Building Code 2010 Section 1507.4.3.
Yield Strength: Min. 80.0 ksi
Corrosion Resistance: Panel Material shall comply with Florida Building Code
2010, Section 1507.4.3.
Panel Dimension(s)•
Thickness: 0.018" min.
Width: 24" Coverage
Rib Height: 3/8" major rib
Panel Rollformer: Metal Rollforming Systems
#9-15 x 1-1/2" Woodgrip with sealing washing in the flat of the panel or
Panel Fastener:
approved equal, %" minirpum penetration through plywood.
Corrosion Resistance: Per Florida Building Code 2010, Section 1506.6, 1507.4.4
Substrate Description:
Min. 15/32" thick, APA Rated plywood over supports at maximum 24" O.C.
outside the scope of this
Design of plywood and plywood supports are
evaluation. Must be designed in accordance w/ Florida Building Code 2010.
Design Uplift Pressures:
Table "A"
EMaxlmum�T�otalplift Design Pressure: 94.25 psf131.0 psf
12"-12" 9.5"-2"-9.5"
Fastener Pattern: 16" O.C. 16" O.C.
'Design Pressure includes a Safety Factor = 2.0.
,t%111111111II
�% N, E. Z. -*eji
C E N S D�,t► �i
F
� • V .fin i
No. 47
lie
•a • STATE OF : a
�; O RI 5��.
stir A�raia. i�, SS . , •�ij ,�
mN AL
February 12L',`�012
FL# 11651.13 R1
26 Ga. 5V Crimp Roof Panel over 1 2"
5-V CRIMP EXPOSED FASTENER SYSTEM
6V GRIMP PANEL p. MEM RANEOF
FASTENER 09
,�,.,,.�. � .saax,.,n•,�ozac
v,.)zhL HYAO
12" O.C. MAIN FIELD
6" O.C. pER TER
26 Ga. 5V Crimp Roof Panel over 1/2"Plywo6d
4
'`6ssttttltIts,
{,AGE E.
i
J
y1�ENS�•.�,r+� -
t, i1.OA, l<�'
�r78 No.449
ST 7 F' tk ti rUALF04r. QA 15914
6.O R 1e
.J/ ��'.,...
2012
27-112" F1at S-bck Nica-terial For 24" Coverage..
Note All Radii 0.05
26
For 24' Coverage
241 Coverage
7/16" %--112z,
'7/8h
Fixed Adjusto.bte Ad jug' aole
Overlap Ribs Center Rid -Underwb Ribs ��