Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSOFFICE USE NLl': ' Date: < l P Due: Receipt# Permit # . I. 2. 3. 4. PLANNING & DEVELOPMENT SERVICES C BUILDING & CODE REGULATION DIVISION l 2300 Virginia Avenue BY IJv Ft. Pierce, FL34982-5652 St. Lucie COunty 772-462-1553 APPLICATION FOR ALUMINUM STRUCTURES PERMIT ALL INFO MUST BE COMPLETE & FILLED IN TO BE ACCEPTED PROJECT INFORMATION LOCATION/SITE ADDRESS: 10108 CROSBY PL, PSL FL PROJECT NAME- GAMPANE L ^ SITE PLAN NAME: PROPERTY TAX ID #: 3327.709.0019.000.5 LEGAL DESCRIPTION (attach extra sheets if necessary): POD 26 AT THE RESERVE PHASE II CYPRESS POINT LOT 64 (OR 3276-1709) 5. PLAT BK PAGE BLOCK LOT 64 6. PARCELSIZE: ACRES/SQ FT. 22 LOT DIMENSIONS 0?. -t & tr 7. SETBAC.KS (ACTUAL) FRA� 2 BACK: �'ZZ RIGHT SIDE:'?-�� LEFT SIDE: S. TYPE OF STRUCTURE (CHECK ALL APPROPRIATE BOXES FOR EACH AND EVERY TYPE OF STRUCTURE) TYPE OF CONSTRUCTION N = New A = Addition R = Rebuild SG = Slab on Grade SR = Raised Slab WD = Wood Deck DIMENSIONS SQUARE FEET OF CONSTRUCTION ❑ SCREEN ROOM ❑ NEW ❑ EXISTING X ❑ CARPORT/PATIO ROOF ❑ NEW ❑ EXISTING X ❑ HABITABLE GLASS ROOM ❑ NEW ❑ EXISTING X ❑ CAT 1. 2 OR 3 SUNROOM ❑ NEW ❑ EXISTING X ❑ ALUMINUM COMP. SHED ❑ NEW ❑ EXISTING X ® POOL ENCLOSURE N ❑ NEW EXISTING 7 /' /&X p /-� 3 ` ?V ❑ . M H ROOF OVER ❑ NEW ❑ EXISTING X ❑ ROOF SYSTEM , OVER EXISTING ACCESSORY STRUCTURE ❑ NEW ❑ EXISTING X ❑ OTHER: ❑ NEW ❑ EXISTING X ❑ ALUM POOL FENCE Linear feet TOTAL SQUARE FOOTAGE OF CONSTRUCTION 7 V 9. VALUE OF CONSTRUCTION: $ f The value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County reserves the right to question and/Or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar typi:s of construction activities. If the value is $2500 or more, a RECORDED Notice of Commencement must be submitted PRIOR TO FIRST INSPECTION. Si,CCDV Form No.: 001-0,2 Rev.0412612010 OWNER INFORMATION NAME: DOMENIC CAMPANELLA ADDRESS: 13 EMMONS DR CITY: CLIFTON PARK STATE: NY ZIP 12065.1681 PHONE (DAYTIME): (- 518.368.9971 EMAIL: FILL IN NAME AND ADDRESS BELOW IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE: FEE SIMPLE TITLEHOLDER: ADDRESS: CITY: STATE: ZIP PHONE (DAYTIME): OONTRACTOR INFORMATION S''ATE OF.FLO'RIDA REG./CERT #: . ; CBC1254009 ST. LUC1E'COUNTY CERT #: 25678 BUSINESS NAME: FLORIDA SCREEN BUILDERS, INC QUALIFIER'S NAME: RENE M CANTIN ADDRESS: 3269 SW 42ND AVENUE C)TY: PALM CITY STATE: FL ZIP 34990 PHONE (DAYTIME): { 561) 753-7734 FAX NO. (561) 753-7634 email: floridascreenbuilders@comcast.net ARCHITECT/ENGINEER: 2010 AAF GUIDE ADDRESS: CITY: STATE: ZIP PHONE (DAYTIME): NOTE: IF APPLICABLE, SUBCONTRACTOR AGREEMENTS MUST BE ATTACHED TO APPLICATION FOR ROOFING, ELECTRIC, PLUMBING, AND HVAC LONING REQUIREMENTS All such 'ctures will be subject to the requirements of the ST. LUCIE COUNTY LAND DEVELOPMENT CODE. Ly" 2 scaled plot plans showing lot size, dimensions of existing host structure, and proposed aluminum addition. All setbacks including front, side, rear and distance between adjacent property structures in MH Parks shall be indicated on the plot plan, ❑ 2 sets of color photos for all stone damaged areas to be reconstructed. One picture must include house address number for inspection Verification. ( not required for construction unrelated to storms) OFFICE LJSE ONLY SECTION TOWNSHIP RANGE MAP NO. Additional ZONING LAND USE LOT CVG % Pen -nits Required REPORT BIMS FEE MISC FEES $ TOTAL FEES CODE- 'SUILDING & ZONING REVIEW FRONT PLANS VALUE OF CONSTRUCTION REVIEW COUNTER ZONING SUPERVISOR EXAMINER VEGETATION USING ICGTABLE DATE COMPLETE 7� ®� INITIALS CERTIFICATION: this application is hereby made in order to obtain a permit to do the work and installations as indicated, and to obtain a certificate of capacity, if applicable, for the permitted work. NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE TO APPLICANT: IN THE EVENT IT IS NOT YOUR RIGHT TITLE OR INTEREST THAT IS SUBJECT TO ATTACHMENT, THE APPLICANT DOES HEREBY MAKE A GOOD FAITH PROMISE TO DELIVER A COPY OF THE ATTACHED CONSTRUCTION LIEN LAW NOTICE TO THE PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT, AND DOES SO AS A CONDITION PRECEDENT TO THIS PERMIT 1. If utilizing the AAF Guide to Aluminum Construction in High Wind Zones, I the Contractor/Owner Builder hereby certify that the components being used, fasteners type and fastening pattern meet all the requirements for the designated wind zones established by the county and take full responsibility for complying with the submitted design of the structure being permitted. 2. I further certify that all the foregoing information is accurate, that no work or installation has commenced prior to the issuance of a permit and that all work shall be performed in compliance with all applicable laws regulating construction and zoning in this jurisdiction. I understand that separate permits may be required for ELECTRICAL, and HVAC, etc., not otherwise included with this building permit application. I ,the Contractor !Owner ilder, have verified that the existing foundation eets the requirements of the Engineer of Record and is in adequate dition to withstand the uplift and weight of the inum structure and said structure will not exceed the footprint of t e ructure that was in existence prior to removal storms. OWNER OR CON TOR SIGNATURE STATE OF FLORIDA COUNTY OF PALM BEACH the foreegg�oing instrument was acknowledged before me me this- (ic) day of y 20 , by RENE M. CANTIN who is personally known X tome, or who has produced as identification. C Signature o _ IMPORTANT NOTICES: SIGNATURE STATE OF FLORIDA COUNTY OF PALM BEACH The foregoing instrument was acknowledged before me me this a—,) day of /—[/4 y .20 /-.?' . by _RENE M. CANTIN , who is personally known X to me, or who has SHE law - my COMMISS, p # n EXPIRES May 15, ZZ^IIII„ Signature of Notary (Seal) • TWO (2) SIGNATURES ARE REQUIRED. EACH SIGNATURE MUST BE NOTARIZED. IF APPLYING FOR THIS BUILDING PERMIT AS AN OWNER/BUILDER, THE OWNER MUST PERSONALLY APPEAR, IN THE OFFICE LISTED ON THE FRONT OF THE APPLICATION, TO SIGN THIS APPLICATION & THE OWNER/BLDR AFFIDAVIT. • ALL SIGNATURES ON APPLICATION SUBMITTED SHALL BE ORIGINAL, SIGNED IN INK. COPIES, FAXES, OR STAMPED REPRODUCTIONS ARE PROHIBITED. • WHEN A PERMIT IS AVAILIBLE FOR ISSUANCE BUT IS NOT PICKED UP WITHIN THIRTY (30) DAYS AFTER NOTIFICATION OF AVAILIBILITY, IT WILL BE VOIDED. IF THE APPLICATION IS RESUBMITTED, AN ADDITIONAL FEE WILL BE CHARGED. PLAN REVIEW SPECIFICATION CHECKLIST PLEASE PROVIDE ONE OF THE FOLLOWING: ❑ 2 Sets of Detailed Plans: Dated, Signed & Sealed by an Engineer or Architect holding a Florida State professional license. ❑ 2 Sets of Detailed Plans: Designed in accordance with the AAF Guide to Aluminum Construction in High Wind Areas. ❑ 2 Sets of Detailed Plans: Designed in accordance with any Approved Manual per fs-489.113. (1) ANY PLANS SUBMITTED WITHOUT COMPLYING WITH THE FOLLOWING SE -[ALL BE RETURNED WITHOUT APPROVAL. ALL PLANS MUST BE IN INK AND ANY NOTATIONS IN PENCIL WILL NOT BE CONSIDERED A PART OF A SUBMISSION. • All plans must be legible and must be designed in Architect's Scale on pages which are 81/2" x l 1" or larger. • All relevant tables & details, if using a manual, must be properly highlighted and must match design checklists & drawings. • The plan view must include all dimensions; the location of the host structure and all materials must be sized and identified thereon. ' • All elevations must be shown, including 4'h wall detail, dimensions and all material must be sized and identified. • All primary and secondary carrier beams, spans, spacing, gauges must be shown [Example: 2" x 8" x .072"]. • All methods of fastening or other details which are relevant to the design must be identified on the Plans. • All upright column heights, sizes, spacing and gauges must be shown as follows: [Example: 3" x 3" x .050"]. • All chair -rails, roof purlins, girts, channels, knee -bracing, k-bracing, cable bracing or any other required component must be sized and identified. • All ridge beams and super gutter or fascia attachments must be identified. • All roof pans or composite panels, with gauges and spans, must be sized and identified. • All footing, slab and iSO pier,designs must be on the plans, per the Architect / Engineer's plans & specifications. • All light metal alloys which are utilized shall be designed in conformity with the Florida Building Code of 2007, Chapter 20, including 2006 revisions. • Barrier railings, if utilized, shall have all materials, fasteners and height specified and shall have self -closing, self - catching gates with picket spacing. (11) SITE CONSTRUCTED SHEDS, HAVING ANY ALUMINUM COMPONENT, SHALL MEET ALL OF THE ABOVE REQUIREMENTS AND THE FOLLOWING ADDITIONAL ITEMS: (A) 2 copies of the current product approval [i.e. N.O.A. or State of Florida approval] with the proposed "opening" or cladding component highlighted and with fasteners and design pressures, per FBC 1714, clearly identified. (B) 2 electric schematics, in accordance with the N.E.C., if applicable. (C) Design pressures, per ASCE-7, identified on the openings of all Plans. (111) HABITABLE ROOMS/ADD1TlONS DESIGNS SHALL MEET ALL OF THE ABOVE REQUIREMENTS, EXCEPT AAMA SPECIFICATIONS, AND CHAPTER 13 OF THE FLORIDA BUILDING CODE. (IV) SUNROOMS (as defined in R202 and FBC 2002.6) MAY BE CONSTRUCTED, SO LONG AS THEY MEET ALL OF THE ABOVE REQUIREMENTS AND MUST BE 1N STRICT COMPLIANCE WITH AAMA/NPEA/NSA2100.02 AND MEET THE FOLLOWING ADDITIONAL ITEMS: (1) The designer or engineer will state on all Plans, which Category of Design [3.1.2] will be used, inclusive of the definition. (2) if designing a Category 4 or Category 5 structure, as defined in the current Edition of 3.1.2.4 and 3.1.2.5, proper energy calculations and long form equipment sizing calculations shall be required, pursuant to Chapter 13 of the current State of Florida Building Code. (V) MOBILE HOMES (FAC 15C-2.0081 - FAC 15C-2.0072): ALL STRUCTURES ADJACENT TO OR NEVI-' ROOF SYSTEMS (Pan or Composite) OVER EXISTING ADJACENT STRUCTURES TO A MOBILE HOME SHALL REQUIRE: (a) A 0' wall or a current, signed original manufacturer's attachment approval letter which includes the model number, serial number and current owner's name and street address. (b) That the complete guide to H.U.D. specifications be strictly adhered to. (c) A Certified Florida Engineer may design the manner of attachment of the proposed structure to the host house but shall assume frill responsibility for both structures' integrity by site specific documentation. JOSEPH E. SMITH, F THE CIRCUIT COURT - SAINT LUCIE TY OFILE # 3838423 OR 3522 PAGE 164, Recorded 05/28/201 11:04 AM I 5,0�--O�;Zq RDR=kmmiD; MiC ST LUCIE D1 4WA DAVEME PNA WY, FL 3" malaf NOIUK• L1To77Ctr. Of COA1I11QIT!llu�ut r Ttu slur npdv dot win 6a umdrto eerria n.l popatJ'. tod b dwadtam pith Carprer 71D, Plolidr 9hAu4dr fdla�l W Wolm.dm L peafdod in d�LNaieodConmmamvt t. Iemarrfoa wrwrirr pgtt arm}uade. �ra..r.++... unirtb)T,ts fat.ro,oa aaz7-7tn�oof�mos pypp THE RESERVE PHASE n dlorlt Hutt for 64 drm: Yc! 10108 Croablr PI POP 29 AT THE RESERVE PHASE H g=E$3 PONT LOT d (og 32MI701- 2. mmmLoa owns roinomtn tum POOL ENCLOSURE D. OtraUt"INK"MOALIEU DUCILIrATM IFTM LINUCONfACIWMIEW OOaOVff*= r Damanle C@!Mnalb Rita Camoandta 13 Emmom Dr Clnlan Park NY 12CI PROPERTYOWNER cNrw.tlsafbr.M•rWMrw�.riw on 1mw b. * t LLIrrY.lRaRalWtdt FLORIDA SCREEN BUILDER& INC tll.�i`IMOM= 3269 SW42ND AVENUE, PALM CRY, FL N% nfArm.mr: mil7n7m r. iUMV RMFAMct... wr trio Mnaw: rur.a Ltt.rrdt111I l \ rm-t. f. R IiIp4'igAMG tvrr'r./ics ►ft�. rlr 7, AroOo.udhiolbiSbba Plorid.dmlpr.diy0wmupnWONnoti maghedomanugmybd.rv.duportdadby Siot471T.13 (I) (� L47ad6lOmd.c "rw1.wAo FLOMSUM BULD8B11Ci=SWG10AYEMUF, PALM OrY.FLNM _ ►fw�dddrdp+rrpraic dsilN.7fif ROMASO 1. Rin iddYim 1p Irbowfahmialt: Rwtdri/Imr d m twlvi • oaiY ddv [Jaor's Nodes r Yewidd im 8.ada 71D.q (1) nL Plaidr s1r0.a 1 r�1.r�R.rRE.Mmldy�rrl7m..t19!<D6MIMG riMltN Q1lD AYEM16 MUMMY jfU11N p. I.pieY7aa dri daxtar ofoarmsfllafmwd (b apb.dm d.lr nrynot w b6ri tbs dawmurlm ad flnrl p.Ymduto 6s "MI -Ow- but win ba 1 YIN Far dodro drroadoa mkw A dRmrlt do. it cpodbd):-_ 20 MOW; 'how am "Offll. It AWN tkdrp ultrdpojlry.Idmintw thaw rod bfartsdnsaotkoofmrmrolpmfotand6alddlrobftrfd6m , amt alb 6r bmt dmy hod.dp and b0bg * � i,n..,wdl * RltaCllwrwlr ArimAMOQ.mlWmmrd► vOr.de fm•I,imiih dgirwlNtipormlri7lsmomm) urrm7R.urMd NOTAWINWION brad W Cmtnq� of tx Y*pAvga►w4�rmtn.rw...rJmowwdpdPrmi.meddr /7—�' d,yd_1"^F •Yp13 * ty -0aamslaGopdWaaLRb o OWNER O 6r /O/O� CtCd GYi Hnf ; f ow r alm...ei Omar. tueoy rloml b ) (mndpmgglbth fd�tao nkl�ddvdrwatrd) L pwam any IIaoma _�v Rw"W ldrmlEmda._ To. didpdAvadam Fka&mcd ltla:.m 4r.1060141(SMWdW (WirKT)pr,vtlrmp %me afNmN'P(btl.)•._`. " t�oF11�MikUL IV Pub�1KA 3WD No i�4R c(NawYark Old tr�seTatoga Cou N(Y. b�!lEirDires Nov. 7, 02 STATE Of FtOflISA' ST. LUCIE COUNTY THIS IS Tn r.I:nTlCV TUATTLrra Ir. . Tf OI By DIt DEVELOPMENT SErfl°ICES DEPARTMENT ® Resldeiana1 / Comme vial Building ' Perffiit Checklist .s1T.E °-�� 1?��iM1T �NUeNI��I� TECHwgAN:- .. 6-wSba. rra General:, Yes ❑ No ❑ N/A Application completely filled out with Notarized Signatures ........................ ,�,/ Sub Summary list with contractors, names & county & state certification numbers.. ❑ Yes El NO LJ N/A Sub Agreements with Original Signatures ...... ......................................Yes ❑ No [ErN/A Owner / Builder Affidavit.................................................................... ❑ Yes ❑ No -[:I'N/A Owner /Builder Electric Affidavit........................................................ ❑ Yes No [Z N/A Filled Land Affidavit ................................................ ...... . ... ❑ -Yes. ❑ t o [ 1�/A ❑_No ErN1A �GEO or Recorded Warranty Deed .......................................................... .. ... ..................................: ❑ Y�§ " Recorded Notice of Commencement...................................................... ❑ Yes -❑ No �N/A Utility Agreement or Payment Receipt .. • . • • • . • .......... • • • • • • • • • . • • • • • . • • • • ❑ Yes ❑ No ® N/A Vegetation Removal Permit ....................................................... ....... ❑ Yes ❑ No N/A Non Conforming Lot of Record........................................................... ❑ Yes ❑ No [l N/A Plans talcullations &z Attachments (3 copies commercial 2 copies residential) p Complete set of plans with Engineer / Architect Raised Seal ....... I ............. ' X Yes ❑ No ❑ N/A p , Truss Plans Reviewed and Approved by Engineer / Architect ...................... ❑ Yes ❑ No ®-N/A Landscaping and Parking Plans ................................................ N o E3-N/A Three (3) copies of Approved Site Plans .......................................... .. o [TN/A Two (2) Sealed Surveys or Plot Plans with Dimensions, Finished Flo L:o ❑ N/A Elevation and Setbacks............................................................... m [�"1�/A Health Department Approval Stamped on Survey and Floor Plan ................ ❑ Yes ❑ No 0-N/A Health Department Food Establishment Permit Stamp on Floor Plan ............ ❑ Yes ❑ No Ef /A Manual "J" or' Manual "N" Calculations ................................................ ❑Yes ❑ No ❑ N/A Signed Energy Calculations................................................................. ❑ Yes ❑ No 0�/A Sealed Wind Load Compliance Certification ........................................... ❑ Yes No EN/A Product Review Affidavit................................................................... ❑ Yes ❑ No ❑`9/A Page l of 2 Z fo Z asvd (paiuud) oumm d I V/M ❑ ON ❑ SOA ❑ ........:.........................y .. juau oBumIN gvAojE) oag jt'nozdd`v' «V„ ss1613 If/N ❑ ON ❑ SOA ❑ ............................................................. u �oojag .zoj ailiZ jo Adoo VIN ❑ ON ❑ $aA ❑ ..................................... `uoi��ooiag ao3 u dag uotloodsq owoH a�igoIilT V/.M ❑ ON ❑ SOA ❑ ................................................................................... �laa *IS V/ICI ❑ ON ❑ saA'❑ ........................... ...................... ( ddoo 1) Isar Jolowo ouad pauBiS /ICI ❑ ON ❑saA ❑ ............. Swo mooQ .Bumoom xaznlounuUN. VIN ❑ ON ❑saA ❑ ..................................... . js y� uoiltqeisaI pay do -has xaamotpuvyN VIN ❑ oil ❑ saA ❑ ................................:.... (usvj zQ umoq ais) looggjOM IRJOcl . - (s . oat 0 a-atjL auaoH apq®N Puy Ad, .. VIN [] `oI�I .❑'-sal •-❑ .._ .. _ _ . -sjautq��-=u�ts-.xo =aft c�mg - - -- VIN ❑ ON ❑ saA ❑ ....................................................... ltn�p adrospuuZ u is puno-Tf) `Fz/ICI ❑ ON ❑saA ❑ .............................................................. JjAspWV 1at=g food. VIN ❑ ON ❑ 90A ❑ ............ ............................ I.. sxaau!Bug jo .dioo xo QWt�C13S `d�Q V/.K ❑ ON ❑ saA ❑ ....... .................... Apun3_4PIN io jntoiaunaoD SE daQ ax!3 xoj QD . ................................................ xoAuadvd 1tuuad qua daQ oH niPto-a., ......:........... . s nfN'ai. NOBb`b'�Ol , 311. op 0 - � 4 2) 3) 4) 5) 6) 7) GENERAL REQUIREMENTS COPE: The prescriptive methods presented in this construction guide provide wind resistant de- ns and construction details for various types of aluminum framed patio and accessory struc- tures, lumber framed utility sheds, secondary covers for, mobile home roofs, glass enclosures (which may also be known as "sunrooms'7 and handrails and guards. LIMITATIONS: a. Provisions of this construction guide are intended to insure structural integrity for resisting wind loads. Notes are provided at the beginning of each chapter specifying general param- eters for each structure type. Where specific construction requirements are not given, ap- propriate requirements of the Florida Building,Code shall prevail. b.. When an individual project design fall outside of the range of parameters listed in this guide, the design shall be reviewed for wind resistance by a design professional when re- quired by the building official. Individual elements of a structure not in. strict compliance with or addressed by this construction guide may be engineered without requiring engineering for the entire structure, according to the requirements of the Florida Building Code. It is recognized that many alternatives are available to the designer for providing wind resistance. This guide does not intend to prevent the use of such structurally equivalent alternative methods (FBC 104.1.1). .MATERIAL SPECIFICATIONS: a. Screen shall have a maximum density of 20X20 mesh with a maximum thread diameter of .013". b. Aluminum extrusions shall comply with ASTM B 221 and have a minimum wall thickness of .040" (actual dimension without tolerance). c. Aluminum sheet and plate shall comply with ASTM B 209. d. Steel fasteners shall have a minimum ultimate tensile strength of 60 ksi and a maximum ultimate tensile strength of 120 ksi and shall be coated for corrosion resistance. e. For foundations, #5 bars shall be used and minimum concrete cover over reinforcing bars shall be 3" where the concrete is cast against and permanently in contact with the earth; or, 11/2" Otherwise. FABRICATION REQUIREMENTS: a) Re-entrant cornets shall be filleted to a radi s of at least W. b) Bolt hole diameters shalleed the bolt 1 1 ".. INSTALLATION REQUIREMENTS: a. Plumb and Level Tolerance: Members shall not deviate from level or plumb by more.than one half inch (1/2 1 in 10 feet. b. Straightness Tolerance: Members shall not deviate from straight by more than one quarter inch (1/4'0 in 10 feet. GENERAL USER NOTES 1) Extrusions assumed to be alloy 6005T5 and/or 6061T6 unless noted otherwise. 2) Tables which have numeric entries versus scalar variables (e.g. spans vs. load widths, or spans vs. wall heights) may be interpolated. CONUACED FASTENERS OR AiTACHMpM ARE THE RESPONSIBILITY OF THE. COWNTOR OF RECORD, -- .. /3os - 6,?o�r ST.'LUCIE COUNTY BUILDING DIVISION REVIEWED FOR COMP f�ACE REVIEWED BY DATE _ PLANS AND PERMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2.0 — Page i r Chapter 1 - Screen Enclosures GENERAL NQTES FOR CHAPTER 1 N SCREEN ENCLOSURES 1) Design pressures taken from Table 2002.4, Florida Building Code 2010 (mean roof height up to 30ft) 2) Extrusions assumed to be alloy 6005T5 or 6061T6 unless noted otherwise. 3) Drawings and Details are typically schematic and should not be scaled. 4) For "half mansard" roof configuration, use beam table 101 for mansard shape. 5) "Approved Masonry Fastener" for connection to foundation must meet the following specifications for 21%2" embedment into 2,500 psi (minimum) concrete: a. 3/8" 0: allowable tension 1,055 #, shear 1,716 # b. 1/4" 0: allowable tension 567 #, shear 394 # 6) For mansard beams, connection at host end of beams (i.e. fascia/gutter) height must be equal or greater than the eave height of the enclosure. 7) Tables which have numeric entries versus scalar variables (e.g. spans vs. load widths, or spans vs. wall heights) may be interpolated. CARRIER BEAMS IN SCREEN ENCL95URE� 1) Carrier Beams (Refer to schematic diagrams for limitations) must be horizontal and may not exceed a single span of 16 ft. 2) At least one end of carrier beam must be supported by the host structure. 3) Allowable load widths for carrier beams on Table 112 with accompanying schematic diagram 4) Connect 2x8 SMB post/column at foundation using Detail C2 Concrete Cover: For foundations, minimum concrete over reinforcing bars shall be 3 inches in foundations where the concrete is cast against and permanently in contact with the earth. For No. 5 and smaller bars 11/2" where concrete is formed and will be exposed to the.earth or weather. Where concrete is not exposed to weather, the minimum concrete cover for reinforcing shall be 11/2 inches regardless of bar size. o Note: Table. pressures apply to 20x20x0.013" mesh screen. For 18 x 14 x 0.013" mesh screen, pressures on screen surfaces rroy, be multiplied by 0.88 AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2.0 Page 1 - a Chapter 1 - Screen Enclosures /R�ngl�/�� �H6S�T UCTl�RE D.) 4 (Bea not ced at de qor of hod ea , musi.pli with `\ N h structure II) `• `-� ` `Vai oof sbppo am,knu a suapo fly by h elements rrier be i ► Host Eave & Fascia Y �[Optio lal] Cahrer Beam "p / / ". /• i /• /" / /• /• 1 E�p N o v /' /' /' /' r /' og Puffins [SCREEN/ENCLOSUREJ A cLLI ° c aJ a) T5ypical, ;Comers _✓ / / ,.A / / 0 ZYpcal /� P tr 1 t- z° a Rectangle 1 & Enclosure Length Overall [Overall length of the enclosure shall not be less than the projection] Typical Screen Enclosure Footprint (Size/Shage) Limitations (Schematic 11 General Limitations on Size and Shape Footarint): 1) Screen enclosures must be connected to a host structure (not free-standing) 2) Enclosure may be simple rectangular shape; OR, may consist of no more than 2 contiguous rectangular shapes 3) Included angles in corners must be perpendicular f 100 (800 to 1000); AND, main roof support beams must be perpendicular (within 100) to outboard (a.k.a. longitudinal) wall 4) Size of rectangles governed by member spans per tables except as noted in schematic diagrams 5) No maximum on length overall, minimum length must be greather than enclosure projection 6) Width and projection governed by beam span or 40 ft, whichever is less 7) Screen eave may not exceed 14 ft except for gable end of transverse gable or dome; sloping eave for transverse gable may not exceed 18 ft in height 8) Mean roof height in Exposure C may not exceed 15 ft 9) Typical bay module (typical spacing of posts, beams and purlins) may not be less than 5 ft nor more than 8 ft (refer to schematic elevations) General Notes and Limitations for.Carrier Beams: 1) Carrier beams must be horizontal (flat) no other shape is permitted. 2) Maximum carrier beam span is a single span of 16 ft 3) Carrier beams may not connect to any Super Gutter corner, but must be connected aligned with the host support wall. Page 1 - 1 AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2.0 Chapter 1 - Screen Enclosures Maximum of 2 Bays (one beam only) or 16 ft beyond host structure, whichever is less. Rectangle 2 HOST STRUCTURE (S.F.D.) s mud be platQd outside\ \ - i ner of h ve, mu 4�n with \ \ host\str re wall Cq k G] \ \.\ \\ `•\ \•\ \\\ plain ro suppprt b s rust be pported di r y host ents or ,r, er beam` Host Eave & Fascia /• / O "/ [Optionb"y"Carries BeaFh I/E .I / LEIV— Pur ibis o' w 12 / /'/ 0 ; ' / /' /' [SCREENf-NCLnr SURE]' I TyPiCal. ;corners "( / /" /" / ( 9� TYPOI Rectangle 1 & Enclosure Length Overall [Overall length of the enclosure shall not be less than the projection] Typical Screen Enclosure Footprint (Size/Shape) Limitations [Schematic 21 Maximum of 2 Bays (one beam only) or 16 ft, whichever is less. Rectangle 2 \ \\ \ \\ \\ }4---- HOST RUCTURE F.D.) ain roof \ rt bea \ ust be su orted Cft\ \ , \ directly hos�ele rcarrie beam.\ f \ a Host Eave & Fascia ,�j,-r�-� ram• —,w pA t on Ca [0rrier Beaori cu 01 /[SCREEN ENCLOSURE] . r ' cf'/ / / /' J" / / / / is w 12 G 1 #�10°) 900 �fYP 1rY/,/ +✓emu_° / / / o { -typical"a ;corners ;/' / I / / rT i / n / /" / a I Rectangle 1 & Enclosure Length Overall [Overall length of the enclosure shall not be less than the projection] Typical Screen Enclosure Footprint (Size/Shape) Limitations [Schematic 31 AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2.0 G Chapter 1 - Screen Enclosures U 1 LL 1 1 AB \� K-BRACING OR CABLES FOR ALLOWABLE SPANS, REFER TO: TABLE 101 FOR BEAM SPANS TABLE 102 FOR PURLIN SPANS TABLE 103 FOR POST SPANS TABLE 104 FOR GIRT SPANS TABLE 109 FOR MANSARD SPLICE SPECIFICAT K-BRACING TYPICAL MANSARD ROOF ISOMETRIC INUM COLUMNS MANSARD ROOF SIDE ELEVATION MANSARD ROOF FRONT ELEVATION AIL BRACING RAIL AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2.0 MOPYRIGH'T 2010 NOT TO BE -REPRODUCED IN WHOLEOIt3ISEPARTW1THOU.T-THEWRFTTEN-PAPFLORIDA REFER TO TABLE 109 AND MANSARD BEAM SPLICE SPECIFICATIONS SCREEN EAVE 3; uj w x J Lu w 0 i_ z a U0 CL l7 w Lu R BEAM TO GUTTER & GUTTER TO HOST DETAILS) — — — — — — — — — — — — — EAVE RAIL SPAN OF SCREEN BEAM INTERMEDIATE GIRT FOR ALLOWABLE SPANS, REFER TO: H_ ,' I GIRT (CHAIR RAIL) TABLE 101 FOR BEAM SPANS TABLE 102 FOR PURLIN SPANS .' ,'0/' TABLE 103 FOR POST SPANS TABLE 104 FOR GIRT SPANS TABLE 109 FOR MANSARD SPLICE SPECIFICATIONS REFER TO SOLE CONNECTION DETAIL TYPICAL SECTION / MANSARD v rn r Ln n CD m n o, c c Chapter 1 - Screen Enclosures LAP BEAM (A.K.A. SMB [SELF -MATING BEAM REFER TO EAVE DETAILS--., ,f Page 1 - 13 EAVE OPEN r R` BEAM FLANGE STITCH SCREWS AT 24" .._......... O.C. TOP AND BOTTOM#12 SMS FOR 2X9 AND 2X10, ALL OTHERS #10 SMS SCREEN ROOF BEAMS _�._._...w (SCREEN ROOF SHAPE AND BEAM SLOPES VARY), SELECT PER TABLE 101 BEAM FLANGE TRIMMED TO - - ACCOMMODATE INSERTION OF POST,LAP BEAM WEBS OVER POST AND FASTEN W/ 4 EACH #12 SMS OR #14 SMS PER SIDE OF —" POST/BEAM / ! `y i CHAIR RAIL (GIRT) i [2X3 HOLLOW SHOWN] ' USE TABLE 104 TO SELECT f EXPLODED SECTION / LAP BEAM (A.K.A. SMB [SELF -MATING BEAM ]) SELECT POST PER TABLE 103 CHAIR RAIL (GIRT) [2X3 HOLLOW SHOWN] USE TABLE 104 TO SELECT ,,,,,",£''C ,,.... SOLE PLATE (1X2 OB OR 1X3 OB) V FASTENS TO FOUNDATION WITH 1/4"0 v CONCRETE ANCHORS AT 24" O.C. (PROVIDE 1'/4"MINIMUM EMBEDMENT) N M' SOLE PLATE WANGLE AND CONCRETE EXPANSION ANCHOR SUPPLEMENTAL ANGLES & CONCRETE FASTENERS [REFER TO FOUNDATION CONNECTION DETAILS Cl(a), CI or C2] ` 8t0 C CONCkETE;FOCJNDATiON..(NOMINAL.4"$LA®� UNLUS"OZRWIED,OTHESE' [DETAIL Fl]. TYPICAL [BEAM. BEARING] WALL SECTION AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2.0 Chapter 1 - Screen Enclosures Minimum 5 ft Maximum 8ft Minimum 5 ft Maximum 8 ft _ j{Minimum 5 ft Maximum 8 ftop �£ ¢ " Screen Roof " o Eave Rail (a.k.a. Shoulder)/ Top of Wall o 0 E 7 Q' U E X Z hd Z O V) 0 8 Girt j chair Rail (Secondary Wall Member) Q y . = I ., � a "` Gel i = pia o�a���g G o Sole Plate N 5chPmatiC Elevations for Screen Enclosures with no Intermediate Girt z W W Screen Roof ' o _ it a ac O L, x z 0 LU U z a w O 0 z 0 0 N _ a Schematic Elevations for Screen Enclosures with Intermediate Girt AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2.0 Pagel - 14 Eave Rail (a.k.a. Sh Ider)/ Top of Wall _ E D� a 9pna/�kg�ce � � N Intermediate Girt � � (Secondary Wall Member) ! Minimum 5ft Maximum 8ft Chapter 1- Screen Enclosures 2" FOR MAXIMUM ALLOWABLE BEAM SPANS REFER TO TABLE 112 £ g o m REFER TO TABLE 103 FOR ALLOWABLE SPANS CONCRETE FASTENING PER 'CONNECTION DETAILS C1(a), C1 OR C2 4" NOMINAL PATIO SLAB W/ 6 X 6 X 10/10 W.W.M. OR SYNTHETIC FIBERS ON WELL COMPACTED SOIL, (CONCRETE TO BE 2,500 P.S.I. MINIMUM) °+ t A,.° GRADE ,tea: �� - c �..,.m..... d .. i. '• . „ � . �. '_'x" : max-. -.. A ..l TYPICAL MONOLITHIC FOOTING DETAIL F1 (SCREEN WALL ON 31h" MONOLITHIC PATIO SLAB (ONLY) 1 [DETAIL F1 TYPICAL FOR SCREEN ENCLOSURES UNLESS ADDRESSING ANGLE OF REPOSE (EROSION)] REFER TO TABLE 103 FOR ALLOWABLE SPANS CONCRETE FASTENING PER CONNECTION DETAILS Cl(a), C1 OR C2 2" 4" NOMINAL PATIO SLAB W/ 6 X 6 X 10/10 W.W.M. REFER TO TABLE 112 w —OR SYNTHETIC FIBERS ON WELL COMPACTED SOIL. FOR DEPTH AND WIDTH _ (CONCRETE STRENGTH TO BE MIN. OF 2,500 P.S I.) OF THICKENED EDGE FOOTINGS BY ENCLOSURE BEAM SPANS ji ft GRADE . � ° -• n \/�\\/�\\/� BAR FOR CONTINUOUS REINFORCING EACH #5 FOR 5 d / / .. ° •• °� ' �• ��%� �\ FOOTINGS WIDER THAN 8" Width per Table 112 FOOTING DETAIL F2 (PATIO SLAB W/ MONOLITHIC EDGE FOOTING) 1 Page 1 - 15 1 AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2.0 % Chapter 1 - Screen Enclosures Detail Cl utilized for foundation connections where the post height does not exceed values in Table 105. Cl(a) is a special case where screen wall is fastened to the top of a masonry wall (refer to Cl(a) notes below), Columns (posts/uprights) must not exceed allowable spans in Table 102. APPROVED _ MASONRY ANCHORS BY 21h° EMBEDMENT i� 2"XX%/8" ... . POST / COLUMN ANGLE 2" LONG w ..,_- - 1X2 OB SOLE PLATE 2"XY'X1/8" ANGLE FACE OF SCREEN WALL 4 EACH #14 SMS ! EDGE OF UNDATION INTO POST WEB Typical Cl Post/Column at Foundation 1\ 1 ................... C1 TYPICAL Cl POST/COLUMN AT FOUNDATION \ ' FOR NOMINAL 4" PATIO SLAB, DO NOT EXCEED 23/4" DEPTH FOR CONCRETE ANCHORS, WHERE CONCRETE DEPTH EXCEEDS 31/2" DEPTH, ANCHOR MAY BE EMBEDDED UP TO CONCRETE DEPTH DIVIDED BY 1.25 2" NOTES FOR CONNECTION Cl(a): 1) Cl(a) IS A C1 CONNECTION WITH ONLY 2 EACH 3/8" 0 APPROVED -MASONRYANCHORS 2) COLUMNS MUST SATISFY BOTH COLUMN SPAN TABLE 102 AND 105 (THE LESSER OF THE TWO);. 3) A 1X3 OB MAY BE SUBSTITUTED FOR THE IX2 SOLE PLATE SHOWN POST/COLUMN ; POST/COLUMN CENTER FASTENERS ON 4. i. _ 2"X2"X1/8" ANGLE 2" LONG 2"X2"Xl/8" ANGLE 2" LONG FILLED TOP COURSE 2 EACH #14 SMS INTO POST 0 0 ' WEB EACH SIDE OF POST 1X2 OB SOLE PLATE N 2 EACH APPROVED MASONRY ANCHORS 3/8" 0 X 21h" EMBEDMENT (1/4" 0 MAY NOT BE USED) SECTION / SIDE ELEVATION / Cl(a) _.._......_.. ...............-.............. ._......... .........._..... .... ...... ............._._.................. }... _..............._. (FOUNDATION CONNECTION FOR COLUMNS \ J NOT SUPPORTING K-BRACING) 2 EACH #14 SMS INTO POST WEB EACH SIDE OF POST JLE PLATE G TYPICAL Ci a POST COLUMN CONNECTION DETAIL FOR 8" CMU WALL%, 1 Allowable Post Heights (Spans [ft]) for 2 Each 3/8" 0 Concrete Fasteners Table 105 Post Spacing in feet (Load Width) zone `psf 5.0 5.5 6.0 6.5 7.0 7.5 8.0 110 "1i3 18.5 16.8 15.4 14.2 13.2 12.3 11.5 120 15 16.0 14.5 13.3 12.3 11.4 10.7 10.0 130 18• 13.3 12.1 11.1 10.3 9.5 8.9 8.3 140 21 11.4 10.4 9.5 8.8 8.2 7.6 7.1 Chapter 1 - Screen Enclosures Detail C1 Elevations show the foundation connections for various depth columns (posts/uprights). Columns (posts/uprights) must not exceed allowable spans in Table 102, IX3 SOLE PLATE MAY NOT 2" ; 4" BE USED WITH 2X4 POSTS --• - - 2X4 POST / COLUMN 3" 2" � -- - 2"X2"X1/8" ANGLE 2" LONG v � i 4 EACH #14 SMS INTO POST WEB o,o _/_ 2"X2"X1/8" ANGLE 2" LONG • a 4 EACH APPROVED MASONRY ANCHORS 1/a" 0 X 21/2" EMBEDMENT (3/8" 0 ANCHORS MAY BE SUBSTITUTED) - SECTION SIDE ELEVATION 2X4 POST (FOUNDATION CONNECTION FOR COLUMNS._ NOT SUPPORTING K-BRACING) .1 COLUMN SELECTED FROM TABLE 103 -T- o ' z `v On ... , .. ......... ....� N a APPROVED MASONRY -- ANCHORS BY 21/2" EMBEDMENT 2" X 2" X 1/B" DO OB SOLE PLATE PLAN VIEW SECTION {W/ 1X3 SOLE PLATE) — TYPICAL C1 POST/COLUMN AT FOUNDATION l ; COLUMN SELECTED APPROVED MASONRY FROM TABLE 103 ANCHORS BY z 21h, " EMBEDMENT 2" X 2" X 1/9" E r A ANGLES f m w- DO OB SOLE PLATE FACE OF SCREEN WALL I..... ..'zt WHEN 1X3 OB SOLE PLATE IS SUBSTITUTED: ' USE 3" LONG ANGLE ON SOLD PLATE AND • EDGE OF FOUNDATION 2" i S" 2" LONG ANGLE ON FOUNDATION PLAN VIEW SECTION (W/ 1X2 SOLE PLATE) try Cl 3.zxs SMB POST/ TYPICAL C1 POST/COLUMN AT FOUNDATION -2"X2"X1/8" ANGLE 2" LONG f. -4 EACH # 14 SMS INTO POST WEB 0 o d-2"X2"X1/8" ANGLE 3" LONG / 2X7 SMB POST /COLUMN iX2 OB SOLE PLATE 4 EACH #14 SMS INTO 7. 2" 7" POST WEB (EACH SIDE) r "• A. '•" , t a'-". "'"""�.""'"_'" _ (WHEN 1X3 SOLE PLATE IS 3" a 3-3/4" , /' UTILIZED, ADJUST ANGLE • " ^ "" LENGTHS ACCORDINGLY) 4 EACH APPROVED MASONRY ANCHORS g p 1/4" 0 X 21/2" EMBEDMENT (3/8" 0 ANCHORS J ! 2"X2"X1/B" ANGLE 2" LONG MAY BE SUBSTITUTED) - ? p?p 2"X2"X1/8" ANGLE 4" LONG SECTION /SIDE ELEVATION / 2. ............ x.......... ..................... : 1X2 OB SOLE PLATE (FOUNDATION CONNECTION FOR COLUMNS NOT SUPPORTING K BRACING) r•. 4 EACH APPROVED MASONRY ANCHORS - 1/4" 0 X 21k" EMBEDMENT (3/8" 0 ANCHORS 2X6 SMB Post / Column MAY SUBSTITUTED) r 4 EACH #14 SMS INTO POST WEB SECTION / SIDE ELEVATION / 2X7 POST f Ol «, 3 3l4" (EACH SIDE) (WHEN 1X3 SOLE.......w........_........,.......... ..........__......_.w...........�..._.... v....._._ ._ _._. / PLATE IS UTILIZED, ADJUST (FOUNDATION CONNECTION FOR COLUMNS 2" 4" ' ANGLE LENGTHS ACCORDINGLY) NOT SUPPORTING K BRACING) f'-•-2"X2"X1/8" Angle 2" Long 2X7 SMB CONNECTION DETAIL C1 ALSO APPLIES TO LARGER COLUMNS (MAINTAIN REQUIRED COMPONENT 2"X2"Xl/8" Angle 4" tong SIZES AND FASTENER SPACINGS) � a5 • 4 EACH APPROVED MASONRY ANCHORS 1/a" 0 X 21/i' EMBEDMENT (3/8" 0 ANCHORS MAY BE SUBSTITUTED) SECT PIN / SIDE ELEVATION /. 2X6 POST /C _ (FOUNDATION CONNECTION FOR COLUMNS NOT SUPPORTING K-BRACING) 1) MAXIMUM POST HEIGHT (SPAN)18' 0" 2) FOR DETAIL Cl AND C2, POST HEIGHT OR SPAN NOT LIMITED BY TABLE 105 FOR NOMINAL 4" PATIO SLAB, DO NOT EXCEED 23/a" DEPTH FOR CONCRETE ANCHORS, WHERE CONCRETE DEPTH EXCEEDS Th" DEPTH, ANCHOR MAY BE EMBEDDED UP TO CONCRETE DEPTH DIVIDED BY 1.25 AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2.0 Chapter 1 - Screen Enclosures 8 EACH #14 SMS INTO POST WEB POST / COLUMN EACH SIDE do 3" 3"X3"X:1/8'ANGLE 3" LONG 9 . .... .... 3/8" 0 APPROVED LLI ----MASONRY ANCHORS 0 BY 21/z" EMBEDMENT L& 0 r- IX2.7OR , J­Xf SOLE PLATE En WALL FACE PARTIAL ELEVATION C2 TYPICAL C2 POST/COLUMN at FOUNDATION _A,"_"jj: M MINIMUM COLUMN SIZE FOR DETAIL C2 (SUPPORT OF K-BRACING) 2X6 SMB COLUMN SELECTED FROM TABLE 103 3 3/8" 0 APPROVED ......................... MASONRY ANCHORS BY 21/2" EMBEDMENT ..... ...... . .. . .... 3"Y373/16" ANGLE 3" LONG IX2 OB SOLE PLATE FACE OF SCREEN WALL PLAN VIEW SECTION (wl IX2 SOLE PLATE) ," C2 POST/COLUMN C2 POST/COMN - AT FOUNDATION \ i MINIMUM COLUMN SIZE FOR DETAIL C2 (SUPPORT OF K-BRACING) 2X6 SMB 2' 6" r i 8 . . ........ .. . . . 1. ...... . ............ ................. 2X8 SMB POST/ COLUMN 3. 1, 2" 3-112" 2X6 SMB POST/ COLUMN 3"X3")C1j8" ANGLE 3" LONG --3"X3'%1/8" ANGLE 3" LONG i 8 EACH #14 SMS INTO POST WEB 8 EACH #14 SMS INTO POST WEB -3"X3"X1/8" ANGLE 3" LONG 0 0 -3"X3"X1/8" ANGLE 3" LONG 0 0 (MINIMUM) 10 0 1X3 OB SOLE PLATE 4 APPROVED MASONRY ANCHORS 3/6'0 X 2112" EMBEDMENT 4 APPROVED MASONRY ANCHORS 3/8" 0 X21/YEMBEDMENT . __ C SECTION / SIDE ELEVATION / 2X6 SMB POST C2 2X8,_SMB. POST,,, SECTION / �IDE ELEVATION � ............ .............. I . .... . .... . ........ .......... (LOCATIONS SUPPORTING K-BRACING) 1(LOCATIONS SUPPORTING K-BRACING) 2X8 SMB CONNECTION DETAIL C2 ALSO APPLIES to 2X9 and 2X10 (MAINTAIN REQUIRED COMPONENT SIZES AND FASTENER SPACINGS) 1) MAXIMUM POST HEIGHT (SPAN) 18' 0" (1)(2 OB SOLE PLATE MAY BE 2) FOR DETAIL C1 AND C2, POST HEIGHT OR SPAN SUBSTITUTED AS INDICATED IN NOT LIMITED BY TABLE 105 2" 71 PLAN VIEW SECTION) w FOR NOMINAL 4" PATIO SLAB, DO NOT EXCEED 23/4" DEPTH 3-1, ' 4' . . ............. 2X7 SMB POST/ COLUMN FOR CONCRETE ANCHORS, WHERE CONCRETE DEPTH EXCEEDS 31/2" DEPTH, ANCHOR MAY BE EMBEDDED UP TO CONCRETE . .. . ......... DEPTH DIVIDED BY 1.25 _"3"X3"X1/8" ANGLE 3" LONG 8 EACH #14 SMS INTO POST WEB Detail C2 Elevations show the foundation —;3"X3"X:1/8" ANGLE 3" LONG depth columns connections for various d (posts/uprights). Columns .(posts/uprights) O 1X3 OB SOLE PLATE must not exceed allowable spans in Table 102. 4 APPROVED MASONRY ANCHORS 3/8" 0 X 2112' EMBEDMENT ELEVATION.. SMB Pos-r,/ _SIDE ,_2X7 (LOCATIONS SUPPORTING K-BRACING) AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2.0 Chapter 1 - Screen Enclosures 3/8" 0 APPROVED MASONRY ANCHOR 2111' EMBEDMENT 3" X 3" X 1/a" ANGLE BY 3" LONG IX3 OB (OPTIONAL) 3" X 3" X 1/4" ANGLE 13Y 3' LONG 3/8" 0 APPROVED MASONRY i f 3 EACH ANCHOR 21/2" EMBEDMENT r #14 SMS 2" LONG 3- X 3" X I/." ANGLE ZLL- 1X3 OB SOLE PLATE Y " B 3 LONG EDGE OF CONCRETE FOUNDATION X 3" X 0.072" HOLLOW PLACEKENT- IN ANGLE PLAU-\-/IEYV SE-CrION I EXIERIQRCORNER AT FOUNDATION FOR SCREEN ENCLOSURES IN WIND ZONE 120 MPH AND GREATER 3" X 3" X 0.072- (MINIMUM) HOLLOW- 3- X 3" X 0.072" SQUARE EXTRUSION (MAY OR MAY NOT HAVE SNAP FEATURES SHOWN AND SCREW SLOT ARRANGEMENTS VARY) 2' FOR NOMINAL 4" PATIO SLAB, D 0 NOT EXCEED 23/4" DEPTH FOR CONCRETE ANCHORS, WHERE CONCRETE DEPTH EXCEEDS 3111' DEPTH, ANCHOR MAY BE EMBEDDED UP TO CONCRETE DEPTH DIVIDED BY 1.25 v #10 SMS BY 11/2" LONG @ 16" O.C. IX3 OB 3" X 3" X 1/4" ANGLE BY 3" LONG 3 EACH *14 SMS 2" LONG 3/9' 0 APPROVED MASONRY FANCHOR 2111' EMBEDMENT r-- IX3 OB SOLE PLATE L PARTIAL ELEVAUON EXTERIOR CORNER AT FOUNDATION FOR SCREEN EN A 154P, > CLOSURES IN WIND ZQNE 120 MPH AND GREATER q AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2.0 Chapter 1 - Screen Enclosures 1" X 2" OR 1" X 3" OB @ PERIMETER NOTE #1: USE 1/4"0 X 3" LONG LAGS INTO WOOD HOST AND 1/4"0 X 21/4" LONG CONCRETE SCREWS INTO CONCRETE OR MASONRY CONSTRUCTION (1" EMBEDMENT TYPICAL)/ SPACING 24" O.C. AND WITHIN 6" OF EACH PERPENDICULAR MEMBER 1" X 1" X 1/8" ANGLE (LENGTH EQUAL TO DEPTH OF SOLE PLATE) WITH 2 - #10 X 1/2" LONG S.M.S. AT EACH LEG TYPICAL EACH SIDE, TOP & BOTTOM) u HO$T STRUCTUkE ELEMENTS. • ° pf�� NOTE 1 CONNECTION WITH EXPOSED FASTENERS 1" X 2" OB @ PERIMETER REFER TO NOTE #1-THIS SHEET 2- # 10 S.M.S. FROM INSIDE FACE OF ('PERIMETER EXTENSION INTO SCREW I SLOTS OF PERIMETER (1-1/2" EMBEDMENT MINIMUM) REFER TO NOTE #1- THIS SHEET g I LOST STgUCTURt` ELEMENTS. 4 P CONNECTION WITH CONCEALED FASTENERS PARTIAL ELEVATIONS PERIMETER EXTENSION CONNECTIONS C 1\ J AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2.0 Chapter 1 - Screen Enclosures r P� CQ J f 3 OPEN BACK EXTRUSION \ z 1 X 2 OB @PERIMETER @ PERIMETER FASTEN FASTEN PER NOTE #1 r PER NOTE #1 \\ "' F—CHAIR RAIL OR GIRT\\, 1" X 2-1/4" X 1/8" %RECEIVING CHANNEL 4\ 5 f �777, `> Fc , 0 I 1" X 1" X 1/8" ANGLES (BY DEPTH OF PERIMETER —POST /COLUMN EXTRUSION) WITH 2- #10 X 3/4" LONG S.M.S. AT EACH LEG \ (TYPICAL TOP & BOTTOM) " CONNECTION W/ EXPOSED FASTENERS 1"X2" OR1"X3"OB@ \ \11 I PERIMETER FASTEN PER NOTE #1 \♦� N HOLLOW HORIZONTAL (GIRT) NOTE #1, USE /a 0 X 2 /a LONG LAG SCREWS INTO WOOD ";`, .` HOST AND 1/a"0 X 21/4" LONG CONCRETE SCREWS \ '\ INTO CONCRETE OR MASONRY CONSTUCTION NJ (1" EMBEDMENT TYPICAL) SPACING @ 24" O.C. \�AND WITHIN 6" OF EACH PERPENDICULAR MEMBER 2- # 10 S.M.S. FROM INSIDE FACE OF 1 X 2 OB INTO SCREW SPLINES OF HOLLOW GIRT (1" EMBEDMENT MINIMUM.) CONNECTION W/ CONCEALED FASTENERS f PARTIAL ELEVATIONS 2" X 2" GIRT TO 1" X 2" CONNECTIONS C4 f:ti 4 Page 1 - 25 AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2.0 Chapter 1 - Screen Enclosures 1" X 1" X 1/8" ANGLES 2" LONG WITH 2- #8 X 1/2" LONG ! o S.M.S. AT EACH LEG 0 (TYPICAL EACH SIDE, TOP & BOTTOM) 4 1" X 2-1/4" X 1/8" zo RECEIVING CHANNEL F- 0 i u r a � LU x O I' z CHANNEL ALTERNATE o POST /COLUMN z w i Y CONNECTION W/ EXPOSED FASTENERS = i S 0 4 - # 10 S.M.S. FROM INSIDE FACE OF �— - POST INTO SCREW SPLINES OF HOLLOW GIRT (1-1/2" EMBEDMENT MINIMUM) a a GIRT OR CHAIR RAIL 0 J . «o-.,.e:.,�„r. a. a^s w .x:,ew.. E %.�+.•., x.. .rsas.:r rs77 r....zea .. .. { xr� E w 7 U Uj m SELF MATING POST 0 K' o CD µ CD CONNECTION W/CONCEALED FASTENERS 0 80 a PARTIAL ELEVATIONS / GIRT TO POST CONNECTIONS C5 1 W � AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2.0 Page 226A / Chapter 1 - Screen Enclosures END BAY ("HIP") PURLIN (SLOPE VARIES FROM 0° TO 39°) 2" X 5" X 1/8" THICKNESS ANGLE 11/2" LENGTH (MINIMUM) AT EACH POST/PURLIN W/ #14 SMS 2 EACH INTO POST; 2 EACH INTO EAVE RAIL } 3" X 3" X 0.072" EAVE RAIL (MAY OR MAY NOT HAVE SNAP FEATURES SHOWN AND SCREW SLOT ---*"' o ARRANGEMENTS VARY) EAVE 0 RAIL CONNECTS TO BEAMS VIA INTERNAL #10 SMS X 11/2" LONG ., OPTIONAL 1X3 OPEN BACK EXTRUSION ON BOTTOM OF EAVE RAIL, FASTEN TO POST W/ 2 EACH #10 SMS X 11/2" LONG INTO SCREW SLOTS OF 1X3 AND CONNECT TO EAVE RAIL W/ #10 X 11/2" AT 24" O.C. /y SCREWS CONNECTING OPEN BACK TO EAVE MAYBE OMMITTED WHEN CONTINUOUS SNAP SECTIONS ARE UTILIZED 3" X 3" X 0.072" EAVE RAIL (MAY OR MAY NOT HAVE SNAP FEATURES SHOWN AND SCREW SLOT ARRANGEMENTS VARY)EAVE RAIL CONNECTS TO BEAMS VIA INTERNAL #10 SMS X 11/2" LONG OPTIONAL 1X3 OPEN BACK EXTRUSION ON BOTTOM OF EAVE RAIL, FASTEN TO POST W/ 2 EACH #10 SMS X 11/2" LONG INTO SCREW SLOTS OF 1X3 AND CONNECT TO EAVE RAIL W/ #10 X 11/2" AT 24" O.C. SCREWS CONNECTING OPEN BACK TO EAVE MAY BE OMMITTED WHEN CONTINUOUS SNAP SECTIONS ARE UTILIZED POST/COLUMN POST FLANGE TRIMMED TO LAP WEBS OVER PURLIN AND FASTENED WITH 3 EACH 414 SMS EACH SIDE 1"XI"X 1/8" ANGLE EACH SIDE OF PURLIN W/ 2 EACH #12 SMS EACH LEG SIDE WALL POST/COLUMN SECTION 1) AT SCREEN EAVE ONSIDE WALLS 1�.ie (FOR WIND ZONES 120 MPH AND GREATER i� i 00 i ® ® \ BEAM (MAY BE HORIZONTAL OR SLOPING), SELECT FROM TABLE 301 4 EACH #14 SMS PER SIDE WEB TO WEB (MINIMUM) TRIM BEAM FLANGE TO ACCOMODATE POST AND LAP BEAM WEBS OVER POST WEBS BEAM FLANGE STITCH SCREWS AT 24" O.C. TOP AND BOTTOM #12 SMS FOR 2X9 AND 2X10, ALL OTHERS #10 SMS / T ,t� SECTION (2�1T SCREEN EAVE ON LONGITUDINAL WALLS (FOR WIND ZONE 120 MPH AND & ASTER,) AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2.0 Chapter 1 - Screen Enclosures WHERE PURLINS ARE ADJACENT TO DIAGONAL ROOF BRACING, BRACING CONNECTIONS REQUIRE BACKING PLATES, EXTEND DIAGONAL BRACING BACKING PLATES AND UTILIZE FOR-PURLIN CONNECTION 21/2" X 31h" X 1/8" BACKING PLATE (REQUIRED IN WIND ZONES 120 MPH AND ABOVE) SELF —MATING OR LAP EXTRUSION (SCREW SLOTS) ;= 2"X2"X1/8" ANGLE EACH SIDE 4 EACH #14 SMS INTO PURLIN WEB AND 4 EACH INTO BEAM WEB (ANGLE EXTENDS TO WITHIN 1/4" OF TOP AND f" BOTTOM OF CONNECTING PURLN AND FASTENERS SPACED EVENLY) f' - O ` � � a� � HOLLOW PURLIN (SELECT PER TABLE 103) MAY BE SLOPING OR HORIZONTAL WITH �✓� I 11h" LONG #10 SMS FROM INSIDE \ 0 r BEAM INTO PURLIN SCREW SLOTS `—ROOF BEAM 1/B" BACKING PLATES AND 6 #10 SMS INTO HOLLOW PURLINS. �., REQUIRED IN 120 MPH ZONES AND GREATER, IN WIND ZONES UP TO 119 MPH, USE 4 # 10 SMS INTO PURLINS SECTION 1 ANGLEICHANNEL QR ' INTERNAL FASTENING AT SLOPING PURLINS WHERE PURLINS ARE ADJACENT TO DIAGONAL ROOF 21h" X 31/2" X 1/8" BACKING PLATE ; BRACING, BRACING CONNECTIONS REQUIRE BACKING (REQUIRED IN WIND ZONES 120 MPH AND ABOVE) PLATES, EXTEND DIAGONAL BRACING BACKING PLATES ! AND UTILIZE FOR PURLIN CONNECTION u s � i k 2"X2"X1/8" ANGLE EACH SIDE HOLLOW PURLIN (SELECT PER TABLE 103) 3 EACH #14 SMS INTO PURLIN WEB-- ---/ MAY BE SLOPING OR HORIZONTAL WITH AND 4 EACH INTO BEAM WEB } 11/z' LONG #10 SMS FROM INSIDE (1/8" THICKNESS RECEIVING BEAM INTO PURLIN SCREW SLOTS CHANNEL MAY ALSO BE USED FASTENED AS SHOWN) 1/8" BACKING PLATES AND 6 #10 SMS INTO HOLLOW PURLINS REQUIRED IN 120 MPH ZONES AND GREATER, IN WIND ZONES UP TO 119 MPH, USE 4 #10 SMS INTO PURLINS — ROOF BEAM SECTION / ANGLE/CHANNEL-ORINIERNAL FASTFNTN.Q PURLIN TO BEAM CONNECTIONS 40' AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2.0 Chapter 1 - Screen Enclosures Maximum angle for mansards 39* Maximum angle for gables 45° 011 Splice Plate Alloy: t 606IT6 or5052H32 414 SMS Typical 2 Screws along Centerline of plate evenly spaced. r Internal 6 splice Plate �t F t a r rn v x r � 4�N Screw positions near miter joint may be adjusted t' to accomodate pudin, space between fasteners along miter joint shall be 11h" to 2", maintain maximum and minimum distances between screws. SPLICE SPECIFICATIONS PER TABLE 109 BELOW IYP-ICAL ELDIA—UON FOR BEAM MITER SPLICE [DETAIL MAY BE ROTATED FOR GABLE RIDGE SPLICE, AND MAY ALSO SERVE AS SPECIFICATIONS FOR A STRAIGHT SPLICE, MAINTAIN PLATE AND CONNECTOR SPECIFICATIONS IN TABLE 109 FOR ALL] Table 109 Beam ice Plate Size and Fasten Requirements Beam Splice Plate Requirements for Beans of 600575 alb Beams of 6005T5 all #14 SMS Total Fastener Spaces Member (SMB) Plate Length Ma Req'd Thicknesses Per Side #14 SMS Number of Spaces 6005T5 5052H32 6061T6 Per End Per Splice Horizontal Vertical 2X4 10" 8.7 316" 18" 8 32 2 2 2X5 12" 13.9 3 16" 1 8" 12 48 3 2 2X6 12" 17.4 316" 18" 14 56 3 3 2X7 14" 22.3 316" 18" 14 56 3 3 2X8 18" 66.7 516" 14" 18 72 4 4 2X9 18" 107.0 24 96 6 5 2X10 20" 147.5 �3/8'15/16"' 26 1nd 6 6 Table Notes: 1 6061T6 beams use same plates as 6005T5 beams 2 5052H32 is a sheet alloy, 6061T6 is a plate alloy 3 Ma (allowable moments for beams in in -kips) AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2.0 1 Page 1- 32 Chapter 1 - Screen Enclosures 2" X 2" X 1/8" ANGLE EACH SIDE �Ce rr OF BEAM (MINIMUM 2" LONG) WITH tS�Cu�; p5 pt - 2 EACH #14 SMS INTO BEAM WEB ram RM ,. w EXTRUDED GUTTER BRACKET" BY 6" LONG AT EACH BEAM WITH 3 EACH 3/8" O LAG .......... SCREWS INTO FASCIA (ALSO PROVIDE ate; LAG SCREWS BETWEEN BEAMS ALONG GUTTER AT 24" O.C.) END BAY ("HIP") PURLIN (SLOPE VARIES FROM 00 TO 39°) 1/8" ANGLE CONTINUOUS SHIM (CUT TO ACCOMODATE SLOPE) SUPER GUTTER CONNECTION DETAIL PURLIN TO HOST EAVE 6" LONG GUTTER BRACKET 3 EACH #12 SMS-,-, 1X2 OB --_. 2" X 2" X 1/8" ANGLE EACH SIDE OF BEAM (MINIMUM 2" LONG) WITH 2 EACH # 14 SMS INTO BEAM WEB d9oot�� -:: - 90K I EXTRUDED GUTTER BRACK 6 LONG f' AT EACH BEAM WITH 3 EACH 3/8" 0 LAG ......... SCREWS INTO FASCIA (ALSO PROVIDE .j t :....... . .. .. g L LAG SCREWS BETWEEN BEAMS ALONG GUTTER AT 24' O.C.) ROOF BEAM 3/8" 0 LAG SCREW EACH SIDE OF BEAM THRU (PER TABLE 101)*, 2"X2"X1/8" ANGLE LENGTH SUFFICIENT TO -- ASSURE 2" EMBEDMENT INTO HOST FASCIA BEAM MAY BE SLOPING OR HORIZONTAL 1 1/8" ANGLE CONTINUOUS SHIM ____ - _. ........ _ ........ _._„.._.�... _ (CUT TO ACCOMODATE SLOPE) 2" X 2" X 1/8" ANGLE EACH SIDE OF BEAM (MINIMUM 2" LONG) ................................................................................................ WITH 2 EACH #14 SMS INTO BEAM WEB AND INTO SUPER GUTTER CHANNEL. COVERING OPEN BEAM (INCIDENTAL TO DESIGN) BEAM MAY BE TRIMMED ALTERNATE SUPER GUTTER CONNECTION DETAIL (2) BEAM TO HOST EAVE -1 AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2.0 Chapter 1 - Screen Enclosures f Hfl u R I I ? I I I i I [S�REEN EN60SURE� I [Diagonal Roof Bracing Not Required] I 9 I I I I -+ __--4------4---~~--4------4-- _._,. I i I I I I I i I I I I I I I i E v -- m Ln I I I U` I O EI 1 .'e — � —�I-----i-----K-- m—t----- i v 3: i ma`s I o,'I I ? o " Of E o I i Purlins I I .4 _. _ _.. . —k — — — —,k- — __ _ _.._ v % I % I I ' I �`, SIDE WALL K BRACING , OPTIONAL WHEN SIDE WALL IS a C I I t LESS THAN 3 BAYS K-Braces Screen Wall Dimension Of Screen Endosure Roof Bracing Strategies - Schematic #2 ROOF BRACING NOTES: 1) BRACE FULLY 2nd BAY FROM EACH END BETWEEN BEAMS, ONLY CORNERS IN 1st BAY 2) ORIENT BRACES TOWARD CENTER OF ENCLOSURE AS SHOWN K Braces AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2.0 Chapter 1 - Screen Enclosures I I I I I — — I I Purlins I ,_-_�_a.. 1--____r_-_-- cn EI \\�� I E I E E Ej ml 1m I�. m 1 I `" I Purlins I I I SIDE WALL K BRACING z OPTIONAL WHEN SIDE WALL IS FEWER THAN 3 BAYSto l i I Purlins I LL Screen Wall K Braces 5c[en Enclosure Roof Bracing Strategies - Schematic #3 Projection (Lateral Exposu ), K Brace l / [NLL BRACING i In! 'IN 2rlIBAAY] �_a. __........ ._......_..�,..� m a-0 t: Roof iDiagonal I I ( ,' ._ I I �, N I ` I_ I (_Purlins I — -- -- I I N cN �I DTI IE I �I I 4V IE u v t i C9I w u L ! ml 0 ICO I ml I Ln o I I Roof Diagonal - I o [2nc(Bay I I l g I ECKI �0 I,'� I 0 Purlins-----I-----— i I u i I I I I u I vN -0 K Braces Longitudinal Dimension (Length of Enclosure & partial lateral exposure) Screen Enclosure Roof Bracing Strategies - Schematic #4 AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2.0 N O li O M CL rt O �I 2„ I i —2X3 (0.050" OR 0.072") HOLLOW 7n ADD 2 ADDITIONAL FLANGE STITCH SCREWS WHEN INTERNAL BACKING PLATE IS UTILIZED ROOF BRACING CONNECTIONS MAY ALSO 21/4" X 2" X 1/8" CHANNEL 51/2" LONGBE UTILIZED FOR K-BRACING (WALL BRACING) BOLTS THRU BEAM AND BRACE 3/8"0— — WHEN WALL BRACING CAN BE 2X3, USE (MAY BE SQUARE CUT, MITER OPTIONAL) CONNECTIONS APPROPRIATE TO MATCH .... ................. ............................ . ..... .... ...: THE ORIENTATION OF THE BRACE. 2"X 2"X0.090" HOLLOW TUBE DIAGONAL -- PURLIN ALTERNATE METHOD OF CONNECTING CHANNEL TO BEAM AND TUBE: 4 (EACH SIDE)#14 SMS THRU CHANNEL AND TUBE 4 EACH #14 SMS THRU CHANNEL AND BEAM WEB AND ff INTO INTERNAL BACKING PLATE i I f f I I BEAMS MAY BE SLOPING OR HORIZONTAL ; "R 3/16" X 5" X SPLICE PLATE DEPTH BACKING PLATE (ABUTS PURLIN) NUPE: BACKING PLATE MAY BE A ; INTERNAL WITH BOLT THRU NEAR BEAM WEB ONLY y---" ""' ROOF BEAM Plan View 3 21/4" X 2" X 1/8" CHANNEL 51/1' LONG i BOLTS THRU BEAM AND BRACE 3/8"0 \ 3/16" X 5" X SPLICE PLATE DEPTH BACKING PLATE (ABUTS PURLIN) NOTE: BACKING PLATE MAY BE 3/8 0 BOLTS ;, j/— INTERNAL WITH BOLT THRU NEAR / BEAM WEB ONLY -J > ..... ... 2"X 2"X0.090" HOLLOW TUBE DIAGONAL f ROOF BEAM ---� Self -Mating Roof Beam Elevation View Section SCREEN ROOF DIAGONAL BRACING SCHEMATIC (#2) K-BRACING NOTE: THESE CONNECTION DETAILS MAY BE UTILIZED FOR K-BRACING 3/8" 0 BOLTS � to �l Chapter 1 - Screen Enclosures IL REFER TO TABLE 108 FOR EXTRUSION TYPE AND NUMBER OF SCREWS PER END (TABLE 106 HAS EXTRUSION KEY BY LETTER); AND REFER TO TABLE 107 FOR MINIMUM LENGTH OF BRACING TIONAL 1X3 BELOW HOLLOW EAVE RAIL �GONAL (K BRACE) Partial_ Elevation_Lr K-Brace-at Eave Rail K BRACE SCREEN SIDE GUSSET PLATE SPECIFICATIONS: DIAGONAL (K BRACE) 1) ALLOY 6063T6 OR 6061T6 OR 5052H32 2) MINIMUM THICKNESS .092" 3) SIZE SUFFICIENT TO ACCOMODATE #14 SMS AT A MINIMUM SPACING AND EDGE DISTANCE OF 3/4" #14 SMS (TYPICAL) SCREEN SIDE GUSSET ANGLE BEHIND 4) REFER TO TABLE 108 FOR NUMBER OF FASTENERS/END GIRT OR CHAIR RAIL-� ® ® i I) <' 5) EQUAL NUMBER OF SCREWS INTO VERTICAL AND HORIZONTAL MEMBERS INSIDE AND OUTSIDE DIAGONAL (K BRACE) - ® ® i SCREEN SIDE GUSSET j POST/ COLUMN POST / COLUMN —+ SOLE PLATE..._._.. DIAGONAL (K BRACE) Partial Elevation / K Brace at Girt/Chair Rail #14 SMS (TYPICAL) REFER TO TABLE 108 FOR EXTRUSION TYPE AND C NUMBER OF SCREWS PER END (TABLE 106 HAS EXTRUSION KEY BY LETTER); AND REFER TO Partial Flavatinn / I nwer K-Rrare at Snle Plate TABLE 107 FOR MINIMUM LENGTH OF BRACING i i [CONNECTION DETAIL NOTE: K BRACE CONNECTIONS MAY BE ALSO UTILIZED FOR ROOF DIAGONAL BRACING] 1/8' THICK BACKER 2" X 4" X 1/8" ANGLE INTERIOR 1/8" THICK BACKER PLATE REQ'D ANGLE (LENGTH EQUAL TO DEPTH ; POST / COLUMN OF SCREEN SIDE PLATE) ,` PLATE REQ'D 2" X 4" X 1/8" ANGLE (LENGTH t ! r- '— EQUAL TO SCREEN SIDE PLATE) K & HORIZONTAL ELEMENT 3" DEPTH _ . Edge of Concrete Foundation SECTION J K BRACE CONNECTION Edge of Concrete Foundation SECTION / K BRACE CONNECTION` a AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2.0 Chapter 1 - Screen Enclosures- Exposure B ' 'i ry w �y Allowable Spans for Mansard Beams with a Rise of 4 ft (Maidmum) Table 101(e)S 18/14 Screen Mesh Wall Height: 8 ft Roof Design Pressure: 4.7 psf Wind Zone 150 mph Exposure B Wall Design Pressure: 16.5 psf 6005T5 Alloy Spacing in Feet Beams Self -Mating or Lap Beams '0" 51011 51611 6" 61011 61611 71011 7' 6" 8' 0" 2 X 6 X 0.050 X 0.120 SMB NA NA NA NA NA NA NA 2 X 7 X 0.055 X 0.120 SMB NA NA NA NA NA NA NA 2 X 8 X 0.072 X 0.224 SMB 30'-5" 27'-10" 25'-4" 23'-0" 20'-11" 18'-10" 16-11" 2 X 9 X 0.082 X 0.306 SMB 40'-0" 40'-0" 38'-0" 35'-11" 33'-11" 32'-2" 30'-5" 2 X 10 X 0.092 X 0.374 SMB 40'-0" 1 40"-0" 1 40'-0" 1 40'-0" 40'-0" 1 40'-0" 39'-4" Allowable Spans for Mansard Beams with a Rise of 4 ft (MaAnxim) Table 101(e)11 18/14 Screen Mesh Wall Height: 11 ft Roof Design Pressure: 4.7 psf Wind Zone 150 mDh Exposure B Wall Design Pressure: 16.5 Dsf 6005T5 Alloy Beam Spacing in Feet Self -Malin or La Beams 5' 0" 51611 6' 0" 1 6' 6" 7' 0" 7' 6" 81011 2 X 7 X 0.055 X 0.120 SMB NA NA NA NA NA NA NA 2 X 8 X 0.072 X 0.224 SMB 27-9" 24'-9" 21'-11" 19'-4" 16'-10" 14'-4" 11'-10" 2 X 9 X 0.082 X 0.306 SMB 40'-0" 38'-4" 35-10" 33'-8" 31'-8" 29'-6" 27'-6" 2 X 10 X 0.092 X 0.374 SMB 40'-0" 40'-0" 40'-0" 40'-0" 40'-0" 1 39'-1" 37'-3" Allowable Spans for Mansard Beams with a Rise of 4 ft (Maxhmm) Table 101(e)14 18/14 Screen Mesh Wall Height: 14 ft Roof Design Pressure: 4.7 psf Wind Zone 150 mnh Exoosure B Wall Design Pressure: 16.5 osf 6005T5 Allo am Spacing in Feet Self -Mating or La Beams 51011 5' 6" 6' 0" 6' 6" 7' 0" 7' 6" 8' 0" 2 X 8 X 0.072 X 0.224 SMB 24'-8" 21'-4" 18'-2" 15'-1" 11'-10" 8'-3" 2'-6" 2 X 9 X 0.082 X 0.306 SMB 39'-0" 36'-3" 33'-9" 31'-5" 28'-11" 26'-7" 24'-5" 2 X 10 X 0.092 X 0.374 SMB j 40'-0" 40'-0" 40'-0" 40'-0" 39'-1" 37'-1" 35'-2" AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2.1 I Page 1B - 34 Chapter 1 - Screen Enclosures- Exposure B ALLOWABLE SPANS for Purlins 18/14 Screen For Wind Zone 150 mph Fxp B Table 102 Table 102e W.II Haitxht -n ft Purlin SDadrtq in Feet Self -Mating (or Lap) Beams 5' 0" 5' 6" 6 0" 6' 6" 7' 0" 7' 6" 8' 0" 2 X 3 X 0.050 X 0.050 Hollow 6-9" 6-5" 6-2" 5-10" 5'-6" 5'-1" 4'-9" 2 X 4 X 0.046 X 0.100 SMB 6'-4" 6'-1" T-10" 5'-6" 5'-3" 4'-11" 4'4' 2 X 4 X 0.050 X 0.050 Hollow 8'-0" T-2" 6'-10" 6'-6" 6'-2" 5'-9" 5'-5" 2 X 3 X 0.072 X 0.072 Hollow 8'-0" 8'-0" 8'-0" T-5" •7'-1" 6'-8" 6'-4" 2 X 5 X 0.050 X 0.116 SMB 8'-0" 8'-0" 8'-0" 8'-0" 7'-5" 7'-1" 6'-9" 2 X 5 X 0.050 X 0.050 Hollow 8'-0" 8'-0" 8'-0" 8'-0" 7'-8" T-4" 6-11" 2 X 6 X 0.050 X 0.120 SMB 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 2 X 7 X 0.055 X 0.120 SMB 8'-0" 8'-0" 1 8'-0- 8'-Y' 1 8'-0" 8'-0" 8'-0" 18/14 Screen For Wind Zone 150 mph Fxp B Table 102e nn�..:w.. .., c-A.... 4 a Cl-;- M.,fi- Mi.. - A a\ Wall Hainht a 11 ft Purlin Spacing in Feet Self -Mating (or Lap) Beams 5101, 5' 6" 6' 0" 6' 6" 7' 0" 7' 6" 8' 0" 2 X 3 X 0.050 X 0.050 Hollow 6'-4" 5'-11" 5'-7" T-2" 4'-10" 4'-4" T-11" 2 X 4 X 0.046 X 0.100 SMB 5'-11, 5'-8" 5'-5" 5'-1" 4'-9" 4'-5" NA 2 X 4 X 0.050 X 0.050 Hollow 8'-0.1 6-81. 6'-3" 5'-10" 5'-5" 5.41 4'-7" 2 X 3 X 0.072 X 0.072 Hollow 8'-0" 8'-0" 7-3" 6'-10" 6'-5" 5-11" 5'-6" 2 X 5 X 0.050 X 0.116 SMB 8'-0" 8'-0" 8'-0" 7-3" 6-11" 6'-7" 6'-3" 2 X 5 X 0.050 X 0.050 Hollow 8'-0" 8'-0" 8'-0" 7'-6" 7'-1" 6'-8" 6'-3" 2 X 6 X 0.050 X 0.120 SMB 8'-0" 8'-01. 8'-0" 8'-0" 8'-0" 8'-0" T-8" 2 X 7 X 0.055 X 0.120 SMB 8'-0" 8'-0" 8'-0" 8' 0" 8' 0" 18/14 Screen For Wind Zone 150 mph Exp B Table 302e ... c..-..1- o - c1.....- M.A.- rein.. - A 4*% 1"�11 F1niaM -1A fF :S ci in Feet Self -Mating (or Lap) Beams -Purlin 5' 0" 5' 6" 60" 6' 6" 7' 0" 1 7' 6" 8' 0" 2 X 3 X 0.050 X 0.050 Hollow 5-11" 5'-5" 4'-11" 4'-6" 4'-0" 3'-6" 2'-10" 2 X 4 X 0.046 X 0.100 SMB 51-8" 5'-3" 4'-11" 4'-7" NA NA NA 2 X 4 X 0.050 X 0.050 Hollow 6-7" 6'-2" 5'-8" 5'-2" 4'-8" 4'-1" 3'-6" 2 X 3 X 0.072 X 0.072 Hollow 8'-0"" .7'-1" 6-8" 6-2" 5'-8" T-2" 1 4'-7" 2 X 5 X 0.050 X 0.116 SMB 8'-0" 8'-0" 52" 6-10" 6'-6" 6'-1" 5'-9" 2 X 5 X 0.050 X 0.050 Hollow 8'-0" 8'-0" T-4" 6'-11" 6-5" 5'-11" NA Z X 6 X 0.050 X 0.120 SMB 8' 0" 8' 0" 8' 0" 8'-0" 8'-0" T 6" T-1" 2 X 7 X 0.055 X 0.120 SMB 8'-0" 8'-0" 8'-0" 1 8'-0" 8'-0" 8'-0" 8'-0" AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2.1 Chapter 1 - Screen Enclosures- Exposure B j"7 is 'r , ALLOWABLE SPANS for Primary Members In Screen Walls (Posts/Columns) Table 103e Wind Zone = 150 MPH Design Pressure: 16.5 PSF Exposure B FOR Screen Mesh: 18/14 FOR 600ST5 or 6061T6 Alby Post / column Load Widths or Spacing 4'-0" 4'-6" 5'-0" 5'-6" 6'-0" 6'-6" T-0" 7'-6" 8'-0" 2" X 2" X 0.046" X 0.046" Hobw 5'-9" 5'-5" 5'-2" 4'-11" - 4'-6" 4'-4" 4'-3" 4'-1" 2" X 3" X 0.05" X 0.05" Hobw 8'-1" 7-8" 7'-3" 6-11" 6'-7" 6'4" 6-1" 5-11" 5'-9" 2" X 3" X 0.05" X 0.05" Snap 8'-9" 8'-3" T-10" 7-6" 7'-2" 6'-11" 6-8" 6'-5" 6'-2" 2" X 4" X 0.050" X 0.050" Holow 9'-5" 8'-10" 8'-5" 8'-0" 7-8" 7-4" T-1" 6-10" 6-8" 2" X 4" X 0.05" X 0.05" Snap 10'-5" 9'-10" 91-4" 8'-10" 8'-6" 8'-2" 7-10" T-7" 74' 2" X 5' X 0.050" X 0.050" Hollow 9'-8" 9'-2" 8'-B" 8'-3" 7'-11" 7'7" 7-4" 7'4' 6-10" 2" X 4" X 0.046" X 0.10" SMB 8'-10" 8'-4" 7-11" 7'-6" 7'-2" 6'-11" 6'-8" 6'-5" 6'-3" 2" X 5" X 0.05" X 0.116" SMB 10'-11" 10'-4" 9-10" 9'4' 8'-11" 8'-7" 8'-3" 7-11" 74' 2" X 6" X 0.05" X 0.12" SMB 11'-9" 11'-1" 10'-6" 10'-0" 9'-7" 9'-3" 8'-11" 8'-7" 8'-4" 2" X 7" X 0.055" X 0.12" SMB 13'-1" 12'-4" 11'-9" 11'4" - " 10'-3" 9'-11" 9'-7" 9'-3" 2" X 8" X 0.072"X 0.224" SMB 24'-4" 22-11" 21'-9" 20'-9' 19'-10" 19'-1" 18'-5" 17-9" 17'4" 2" X 9" X 0.082" X 0.306" SMB 29'-11" 28'-9" 27'-9" 26'-9" 24'-7" 23'-9" 22'-11" 22'-2" 2" X 10" X 0.092" X 0.389" SMB 34'-11" 33'-7" 32'-5" 31'-5" 30'4" 29'-2" 28'-1" 27-2" 26'-4" ALLOWABLE SPANS for Primary Members In Screen Walls (Posts/Columns) Table 303f Wind Zone = 160 MPH Design Pressure: 18.8 PSF Exposure B FOR Screen Mesh: 18 14 FOR 6005T5 or 6061T6 Alby Post / column Load Widths or Spacing 4'4" 1 4'-6" 1 5'-0" 5'-6" 6'-0" 6-6" T-0" 7'-6" 8'-0" 2" X 2" X 0.046" X 0.046" Ho9ow 5'-5" 5'-1" 4'-10" 4'-7" 4'-5" 4'-3" 4'-1" T-11" T-10" 2" X 3" X 0.05" X 0.05" Hobbw T-7" T-2" 6-10" 6-6" 6'-2" 5'-11" 5'-9" 5'-7" 5'4" 2" X 3" X 0.05" X 0.05" Snap 8'-3" 7-9" T-4" T-0" 61-9" 6-5" 6'-3" 6'-0" T-10" 2" X 4" X 0.050" X 0.050" HoHow 8'-10" 8--4" 7'-10" 7'-6" T-2" 6-11" 6'-8" 6'-5" 6'-3" 2" X 4" X 0.05" X 0.05" Snap 9'-9" 9'-2" 8'-9" 8'-4" T-11" 7-8" 7'4" 7'-1" 6'-11" 2" X 5" X 0.050" X 0.050" HoOow 9'-1" 8'-7" 1 8'-2" T-9" T-5" 7'-2" 6'41" 6'-8" 6'-5" 2" X 4" X 0.046" X 0.10" SMB 8'-3" T-10" 7'-5" 7'-1" 6'-9" 6'-6" 6'-3" 6'-1" 5'-10" 2" X 5" X 0.05" X 0.116" SM B 10'-3" 9'-8" 9'-2" 8'-9" 8'-5" 8'-1" T-9" 7'-6" 74' 2" X 6" X 0.05" X 0.12" SMB 11'4" 10'-5" 9'-10" 9'-5" 9'-0" 8'-8" 8'-4" 8'-1" T-10" 2" X 7" X 0.055" X 0.12" SMB 12'-3" 11'-7" 10'-11" 10'-6" 10'-0" 9'-8" 9'-3" 8'-11" 8'-8" 2" X 8" X 0.072"X 0.224" SMB 22'-10" 21' 6' 20'-5" 19'-6" 18'-8" 17-11" 17-3" 16'-8" 16-2" 2" X 9" X 0.082" X 0.306" SMB 28'4' 27'-7" 26-4" 25'-1" 24'4" 23'-1" 22'-3" 21'-6" 20'-10" 2" X 10" X 0.092" X 0.389" SMB 1 33'-6" 32'-2" 31'-1" 29'-9" 28'-6" 27-4" 26'-4" 25'-6" 24'-8" AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2.1 Page 1B - 1481 Chapter 1- Screen Enclosures -Exposure B ALLOWABLE SPANS for SECONDARY SCREEN WALL MEMBERS Table 204 (GRITS OR CHAIR RAILS) FOR 110 mph Wind Zones Exp, B Table 204a 18/ 14 Screen IUnit Load= 8.8 psf I .,�rl lA/irlrh / C.arinn Extrusion 4'-0" 4'-6" 5'-0" 5'-6" 6'-0" 6'-6" 7-0" 2X2X.046 Hollow 7'-10" 7-5" 7-0" 6'-8" 6'-5" 6'-2" 5'-11" 2X3X.050 Hollow T-10" 7-10" T-10" 7-10" 7-10" 7-10" 7'-10" 2X4X.050 Hollow T-10" 7-10" 7-10" 7-10" 7-10" ' T-T0 7' SO" 2X3X.072 Holow T-10" T-10" T-10" 7-10" 7-10" T-10" T-10" Maximum Spacing (Vertical) 7 tt o.c.; maximum allowable span 7' lU") FOR 120 mph Wind Zones Exp B Table 204b 18/14 Screen Unit Load= 10.6 psf I nari Wirith / Cnarinn Extrusion 4'-0" 4'-6" 5-0" 5'-6" 6'-0" 6'-6" 7-0" 2X2X.046 Hollow 7-0" 6'-7" 6'-3" 5-11" 5-9" 5'-6" 5'-4" 2X3X.050 Hollow 7'-10" 7'-10" 7-10" 7'-10" T-10" 7-10" 7-8" 2X4X.050 Hollow T-10" 7-10" T-10" 7-10" T-10" 7'-10" 7'-10" 2X3X.072 Holow 7-10" 7-10" T-10" 7-10" T-10" T-10" 7'-10" Maximum Spacing (Vertical) 7 ft o.c.; maximum allowable span 7' 10") FOR 130 mph Wind Zones Exp B Table 204c 18/ 14 Screen Unit Load = 12.1 psf I nari Wirith / Cnarinn Extrusion 4'-0" 4'-6" 5-0" 5'-6" 6-0" 6'-6" 7-0" 2X2X.046 Hollow 6'-5" 6-1" 5'-9" 5'-6" 5-3" 5-0" 4'-10" 2X3X.050 Hollow 7-10" 7-10" 7'-10" 7-10" 7-8" 7-5" 7'-2" 2X4X.050 Hollow 7-10" 7-10" T-10" 7-10" 7'-10" T-10" 7-10" 2X3X.072 Holow T-10" 7-10" 7'-10" 7-10" 7-10" 7'-10" 7-10" Maximum Spacing (Vertical) 7 ft o.c.; maximum allowable span 7' 10") FOR 140 mph Wind Zones Exp B Table 204d 18114 Screen Unit Load = 14.3 psf I rurl Wirlth / Snarinn Extrusion 4'-0" 4'-6" 5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 2X2X.046 Hollow 5' 9" 5'-2" 4'-11' 4'-8" 4'-6" 4'-4" 2X3X.050 Hollow 7'-10" 7'-10" 7-8" 7'4' 7'-0" 6'-9" 6'-6" 2X4X.050 Hollow 7-10" 7-10" 1 7'-10" T-10" 7-10" 7-10" T-10" 2X3X.072 Holow T-10" 7-10" 1 7'-10" 7-10" T-10" 7'-10" 7'-10" Maximum Spacing (Vertical) 7 tt o.c.; maximum allowable span 7' 10") FOR 150 mph Wind Zones Exp B Table 204e 18/ 14 Screen Unit Load = 16.5 psf Extrusion 4'-0" 4'-6" 5'-0" 5-6" 6-0" 6'-6" 7-0" 2X2X.046 Hollow 5'4" 5'-1" 4'-7" 4'-5" 4'-2" 4'-1" 2X3X.050 Hollow T-10" 7-6" 7-2" 1 6-10" 6'-6" 6'-3" 6'-l" 2X4X.050 Hollow 7'-10" 7-10" T-10" 7-10" 7'-10" 7'-7" 2X3X.072 Holow 7'-10" 7'-10" 7-10" 7'-10" 7-10" 7'-8" 7-5" Maximum Spacing (vertical) / tt o.c.; maximum allowable span 7' lU") FOR 160 mph Wind Zones Exp B Table 204f IS/ 14 Screen Unit Load = 18.8 psf I nnrl Wirith / Snarinn Extrusion 4'-0" 4'-6" 5-0" 5-6" 6'-0" 6'-6" 7-0" 2X2X.046 Hollow 5-0" 4'-9" 4'-6" 4'-3" 4'-l" Y-11" T-10" 2X3X.050 Hollow 7'-61' 7-1" 6'-8" 6'-5" 6'-l" 5'-11" 5-8" 2X4X.050 Hollow 7-10" 7-10" 7-10" T-10" 7'-8" 74" T-1" 2X3X.072 Holow 7-10" 7-10" 7'-10" T-10" T-6" 7-3" 6-11" Maximum Spacing (vertical) 7 tt o.c.; maximum allowable span 7' 10") NOTE (Table 104): maximum span of 7' 10" governed by maximum post spacing of 8' 0" AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2.1 Chapter 1 - Screen Enclosures - Exposure B DESIGN LOADS on K Brace Diagonals by Wind Zone and Enclosure Dimensions EXPOSURE B Wall Height: 14 ft TABLE 106 o N o 18/14 Screen Mesh (Panel Widths in feet) (table values in kips) c tm 0 PROJECTION OF FLOW THR CREEN WALLS (ft) a 5 10 15 20 S 30 35 40 5 9.43 0.49 1.37 2.24 3.11 3.99 4.86 5.73 6.60 E 6 10.00 0.44 1.21 1.98 225 3.52 4.29 5.06 5.83 7 10.63 0.40 1.10 1.80 2.51 3.21 3.91 4.61 5.32 r' 8 11.31 0.37 1.02 1.68 2.33 2.99 3.64 4.30 4.95 9.43 0.60 1.66 2.73 3.79 4.85 5.91 6.98 8.04 E10.00 0.53 1.47 2.41 3.35 . 4.29 5.22 6.16 7.10 N10.63 M 0.48 1.34 2.19 3.05 3.90 4.76 5.61 6.47 T'11.31 0.45 1.25 2.04 2.84 3.64 4.43 5.23 6.03 L 9.43 0.72 2.00 3.27 4.55 5.82 7.10 8.38 9.65 E 6 10.00 0.64 1.77 2.89 4.02 5.14 6.27 7.40 8.52 0 7 10.63 0.58 1.61 2.63 3.66 4.69 5.71 6.74 7.77 'i 8 11.31 0.54 1.50 2.45 3.41 4.37 5.32 6.28 7.23 5 9.43 0.82 2.26 3.70 5.14 6.58 8.02 9.46 10.90 E 6 10.00 0.72 1.99 3.27 4.54 5.81 7.08 8.36 9.63 CD 7 10.63 0.66 1.82 2.98 4.13 5.29 6.45 7.61 8.77 T' 8 11.31 0.61 1.69 2.77 3.85 4.93 6.01 7.09 8.17 9.43 0.91 2.51 4.12 5.72 8.93 10.53 12.14 6 10.00 0.80 2.22 3.64 5.05 6.47 7.89 9.30 10.72 Ln 10.63 0.73 2.02 3.31 4.60 5.90 7.19 8.48 9.77 8 11.31 0.68 1.88 3.09 4.29 5.49 6.69 7.89 9.10 5 9.43 1.03 2.86 1 4.68 6.51 8.33 1 10.16 11.98 13.81 6 10.00 0.91 2.53 4.14 5.75 7.36 8.97 10.59 12.20 7 10.63 0.83 2.30 3.77 5.24 6.71 8.18 9.65 11.11 8 11.31 0.78 2.14 3.51 4.88 6.25 7.61 8.98 10.35 For 20/20 Screen Mesh, the tabular values shall be multiplied by 1.136 For K braces 2 panels (side by side on each end), multiply tabular values by 0.6 For K-braces 3 panels (side by side on each end), multiply tabular values by 0.48 Linear interpolation between tabular values is permitted. (kip = 1,000 Ibs) Page 113 - 155 11 AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2.1 D -n Lengths of K Brace Diagonals by Screen Panel Height & Width (all dimensions in feet) TABLE 107 c o Panel Panel Widths M Height 5.00 5.25 5.50 5.75 6.00 6.25 6.50]:j75 7.00 7.25 7.50 7.75 8.00 O 5.00 7.07 7.25 7.43 7.62 7.81 w 8.00 8.20 40 8.60 8.81 9.01 9.22 9.43 D r 5.25 7.25 7.42 7.60 7.79 7.97 8.16 8.36 8.55 8.75 8.95 9.15 9.36 9.57 3 5.50 7.43 7.60 7.78 7.96 8.14 8.33 8.51 8.71 8.90 4 9.10 9.30 9.50 9.71 z 5.75 7.62 _-_ 7.79 ! 7.996 8.13 8.49 8.68 8.87 9.06 9.25 9.45 9.65 9.85 3 6.00 7.81 1 7.97 1 8.14 _8.31 8.31 8.49 8.66 8.85 9.03 9.22 9.41� 9.60 9.80 10.00 n0 6.25 8.00 8.16 ! 8.33_ 8.66 8.84 9.02 9.20 9.38 9.57 1 9.76 9.96 10.15 z _ 6. 8.20 8.36 1 8.51 8.68 8.85 9.02 9.19 9.37 9.55 9.74 9.92 10.11 10.31 3 . 5 8.40 8.55 ; 8.71 . 7 9.03 9.20 9.37 9.55 9.72 9.91 10.09 10.28 10.47 c 7.00 8.60 8.75 j 8.90 9.06 9.22 9.38 9.55 9.72 9.90 10.08 10.26 10.44 10.63 7.25 8.81 8. 55 t 9.10 9.25 9.41 9.57 9.74 9.91 10.08 10.25 10.43 _ 10.61 10.80 r O 7.50 9.01 9.15 9.30 9.45 9.60 9.76 9.92 10.09 10.26 10.43 10.61 10.78 10.97 z 7.75 9.22 9.36 9.50 9.65 9.80 9.96 10.11 10.28 10.44 10.61 10.78 10.96 11.14 = 8.00 9.43 9.57 ' 9.71 9.85 10.00 10.15 10.31 10.47 10.63 10.80 10.97 11.14 11.31 CD CD , G) 2 n O z K Brace Diagonal SELECTION TABLE - TABLE 108 (diagonal bracing extrusion is selected by its length as determined from Table 107, and have an allowable compression value equal to m. n or greater than the value determined usingthe selection from Table 106)X m > EXTRUSION LENGTH OF K-BRACE DIAGONAL (feet) o .. KEY DESCRIPTION 7.0 ; 7.5 8.0 8.5 9.0 9.5 10.0 10.5 11.0 11.5 a A 2X2 X0.046 Hollow 1.658/6 i 1.444/5 1.269/4 1.124/4 1.003/4 0.900/3 0.812/3 0.737/3 0.671/3 0.624/2 W m B 2X3 X 0.05" Hollow 2.480/8 2.160/7 1.899/6 1.682/5 1.500/5 1.346/4 1.215/4 1.102/4 1.004/3 0.919/3 CL C 12X2 X0.09" Hollow 3.034/5 ' 2.643/5 2.323/4 _... 2.058/4 ; .1. 6 3 1.648/3 a _ 1.487/3 1.349/3 1.229/2 1.124/2 v )( D- 2X3 X 0.07" Hollow m3.377/7 - 2.942/7 2.586/6 2.291/5 i 2.043/5 1.834/4 1.655/4 1.501/4 1.368/3 1.251/3 ry E 3X3 X 0.06" Hollow 6 280/16 6.280/16 5.638/14 4.995/12 11 3.998/10 3.609/9 3.273/8 2.982/8 2.729/7 F 13X3 X 0.09" Hollow 10.718/18� 9,336/15 8.206/14 7.269/12 6.484/11 5.819/10 5.252/9 4.763/8 1 4.340/7 3.971/7 Tabular Values: numeric value preceeding the "/" is the allowable brace compression in kips (1,000 Ibs), number following the "/" is the number of #14 Sheet Metal Screws which must be used to fasten the diagonal selected at each end. �n W� CciCOPYRIGHT 2010 NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRrTfEN PERMISSION OF THE ALUMINUM ASSOCIATION OF FLORIDA Chapter 1 - Screen Enclosures- Exposure B .� 4 Allowable Post Heights (Spans [ft]) for 2 Each 3/8" 0 Concrete Fasteners Exposure B 18/14 Screen Mesh ONLY Table 105 Wind Zone (pso Post Sp ding in feet (Load Width) 5.0 5.5 6.0 6.5 7.0 7.5 8.0 110 8.8 27.2 24.8 .7 21.0 19.5 18.2 17.0 120 10.6 22.6 20.6 18.9 17.4 16.2 15.1 14.1 130 12.1 19.9 18.1 16.6 15.3 14.2 13.3 12.4 14.3 16.8 15.2 1 0-, 12.9 12.0 11.2 10.5 150 16.5 14.5 12.1 11.2 10.4 9.7 9.1 160 18.8 12.8 E13.2 11.E 10.E 9.8 9.1 8.5 8.0 Allowable Post Heights (Spans [ft]) for 2 Each 3/8" 0 Concrete Fasteners Exposure B 20/20 Screen Mesh Table 105 Wind Zone (psf) Post Spacing in feet (Load Width) 5.0 5.5 6.0 6.5 7.0 7.5 8.0 110 10.0 24.0 21.8 20.0 18.4 17.1 16.0 15.0 120 12.1 19.9 18.1 16.6 15.3 14.2 13.3 12.4 130 13.7 17.5 15.9 14.6 13.5 12.5 11.7 10.9 140 16.3 14.8 13.4 12.3 11.3 10.5 9.8 9.2 150 18.8 12.8 11.6 10.6 9.8 9.1 8.5 8.0 160 21.4 11.2 10.2 9.4 8.6 8.0 7.5 7.0 AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2.1 Page 1B - 15Z Chapter 1 - Screen Enclosures - Exposure B Wall Heights: 8" CMU: Aluminum: Height Overall: Allowable Wall Heights (feet) 8" CMU Knee -Walls in Screen Enclosures by Fvnnci ira R Wind 7nne 110 120 130 140 150 160 6 6 5 4.5 4 3.5 10 9 9.5 9.5 9 9.5 16 15 14.5 14 13 13 ALLOWABLE BEAM SPANS (Fr) FOR RIBBON P00T1Nl3S TABLE 111 cvnfun ne n CrIrTrTAiC cT71=C Anln rDr)CC_CF(`TrnNAI ARFAS (in2) WIND ZONES 81 911X9" 108 9" X 12" 144 12" X 12" 192 16" X 12" 256 16" X 16" up to 120 26.2 34.9 40.0 40.0 40.0 130 23.6 31.4 40.0 40.0 40.0 140 21.5 28.6 38.2 40.0 40.0 , 150 18.1 24.1 32.1 40.0 40A' . 160 15.9 1 21.2 28.2 37.7 4010 TABLE NOTES: 1) HEIGHT AND WIDTH DIMENSIONS MAY BE REVERSED 2) TABLE MAY BE INTERPOLATED BY CROSS -SECTIONAL AREA Allowable Beam Spans for Monolithic Footings (Details Fl/F2) Table 112 FvnncnrP R (Ream Snans in Decimal Feet) Wind Zone (MPH) I'Nominal Slab ONLY Edge Footings - Depth by Width (Detail F2) 81fX8" (81 in 2) 81X12" 108 in) 12"X12" (144 in2) 12"X16" (192 in2) 6"X16" (256 in2) 110 32.2 40.0 40.0 40.0 40.0 40.0 120 21.7 36.3 40.0 40.0 40.0 40.0 130 19.6 32.7 40.0 40.0 40.0 40.0 17.8 29.,8 36.9 38.0 40.0 40.0 150 15.0 25. 31.1 32.0 1 (40.V 1 40.0 160 13.2 22.0 27.3 28.1 1 37 5 1 40.0 Table Notes: 1) Reinforcing: 1 Each #5 Bar continuous for 8"X8", 2 Each #5 Bars continuous for larger footing sizes listed. 2) Width and Depth dimensions shown on table may be interchanged. Pa6e 1B - 157 AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2.1 ;716 MIN, SETBACK REQ. FRONT ZO SIDES 7 S CNR SIDES /O REAR S TEC CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD CURVE TABLE Curve— Delta Radius engt C1. 4 05 29" 7025, t70 73� 19 C2 4 U5 29 " 1155, 00 52.48 C3 5 4456" 1 D25. 0,0 7 t7Z_.944 � THESE PUN HAVE BEEN REVIEVS 19MMCE WR THE FLONA 10108 CROSBY PLACE PORT SAINT LUCIE, FL 34986 ;6F4t+i own CER"FICATIMA ; t +.9&,S'E&e GERTIRY';trT TMA UDYth#GYF RY SJit EVE * A IRvE MD C[:+.FY3:GC''>2EPstii5Et�7A7S43i Jf h.$�RV['/ PiiEF:-REty U47t7n'ft F.iY D1REfi�P#(i!! Tli1S.� C.s.AiPL7C„.�'=.�.?B$1 THE MINIMUM -TE{;'tixt:llL ftY>\iiC#ARIX'SrL" Q A3 SET vieYf P.Rf?F ESSFC3+{hL i.ANi3 aits2�.'1L4�Sb?�iH�L'"4 P5F4,✓'ifa F1�'=' t"tt�.:}FslBlki{,. TftAitLi K.7LJE F'URu81Al:i' 70472.a5-7, FLOROA SIGNEC / kl� FOR THE. FIRM R' IGUEL ESPIN64 STiATM O FLCtf2PCti' F?S.11 : Pe`(?. 5frJ1 •,7iui.ty,je,cT-a::5r'.':,'i aiJ: r'C:ct'ity „.6'Ctii_^.ry�W.(yc;t!!ri?'.„Y;°i FiiD t.',i7 t-0?2t Qf ,t _!'r,xdR$„t,`:it to Ma,'' :,f ♦yam J-.:.,.'i si'; �'..l,3";tii;'x.G`nXi...c; l4 .t.'.�i ;-r:k; s„at,;ivri h• 'S_ .. .S;«:: 'r:.t. t IC.i.rJ.":iC-,I»'1.CY`f: ..t�,¢7 fAtc�-ti8t Notes: BRICK DRIVEWAY VIOLATES EASEMENT ALONG FRONT LOT LINE. MIGUEL ESPINOSA LAND SURVEYING, INC. 10665 SW 190TH Street Suite 3110 MIAMI, FL 33157 PHONE:(305) 740-3319 FAX #:(305)669-3190 LB # 6463 1E. Accepted By: .4 A.rvm_.'. -' ;:m. Y:;..ar ;a.:xa'x sue.. zme-, azm;s.4. Survey: A-20266 Page 1 of 2 Not valid without all pages -' �:£�a`351 °""aT-�' "i3P".93rS'iq"lS' ew•,Ci,.'ei:.*3.�._.,cr1:`.::a.H.?,"*r..:�^1'+.>xu2,_Pk«L'.'i�'x:[;d�'Yw�Sye'u`w^T.. L3�3'd::�'iv Surveyor's Legend ti.,„,M,.......�.m. PROPERLY LINE STRUCTURE B.R. BEARING REFERENCE TEL. TELEPHONE FACILITIES FND FOUND IRON PIPE / CONC;, BLOCK WALL,- PIN AS NOTED ON PLAT G CENTRAL ANGLE OR DELTA U.P. UTILITY POLE --x--:< {- CHAIN-UNK•FENCE. OR .WIRE EENGE LB# LICENSE # - BUSINESS R RADIUS OR RADIAL E.U.B. ELECTRIC UTILITY BOX —�J—�';--- `woo �� FENCE ` LS# - LICENSE # - SURVEYOR RAD. RADIAL TIE SEP. SEPTIC TANK ---o--- [RON FENCE CALC CALCULATED POINT N.R. NON RADIAL D.F. DRAINFIELD ---_" _ EASEMENT �' ' SET SET PIN TYP. TYPICAL A/C AIR CONDITIONER ---- - CENTER LINE A V CONTROL POINT I.R. IRON ROD'" S/W SIDEWALK WOODDECK ,,- CONCRETE MONUMENT I.P. IRON,PIPE DWY DRIVEWAY ,!� - ,- - ij� BENCHMARK N&D ' NAIL k'DISK SCR. SCREEN -:'. ".i CONCRETE ELEV ELEVATION PK NAIL PARKER-KALON NAIL GAR GARAGE ..7-.,..7,J-- - P.7. �L11� ASPHALT POINT OF TANGENCY D.H. DRILL HOLE ENCL. ENCLOSURE , , q., P.C. POINT OF CURVATURE WELL N.T.S: NOT TO SCALE r My%N BRICK, /`TILE P.R.M. PERMANENT REFERENCE MONUMENT ® FIRE HYDRANT F.F. FINNISHED FLOOR P.C.C. WATER POINT OF COMPOUND CURVATURE ,,, M.H, MANHOLE T.O.B. TOP OF DANK P.R.C. POINT OF REVERSE CURVATURE O.h.l. OVERHEAD LINES E.O.W. EDGE OF WATER -•'- APPROXIMATE EDGE OF WATER P.O.B. pQItJT OF BEGINNING TX TRANSFORMER E-O.P EDGE OF PAVEMENT P.O.C. POINT OF COMMENCEMENT CATV CABLE TV RISER C.Y.G. CONCRETE VALLEY GUTTER COVERED AREA L.s----'-- P,C.P. PERMANENT CONTROL POINT W.M. WATER METER B•S;L, BUILDING SETBACK LINE TREE M FIELD MEASURED P/E POOL EQUIPMENT S•T_L• SURVEY TIE LINE Yr POWER POLE. P PLATTED MEASUREMENT CONC. CONCRETE SLAB C� CENTER LINE 1. ill CATCN BASIN D DEED ESMT EASEMENT R/W RIGHT-OF-WAY C.U.E. COUNTY LTIL'i•Y EASEMENT C CALCULATED D.E. DRAINAGE EASEMENT p,UF, PUBLIC UTILITY EASEMENT LE'A.S:, INGRESS / :'.GPESS EASEMENT L.M.E. LAKE OR LANDSCAPE MAINT. ESIAT. L D E LANDSCAPE BUFFER EASEMENT C.M,C• CANAL MAINTC.RANCE EASEMEN? U.E. UTILITY EASEMENT R.O.[. ROOF OVERHANG EASEMENT L-A.£- LIMITED ACCESS EASEMENT ANCHOR EASEMENT k. E. r•�• s4 .. :.vz;.R::Za�'ffi�'�'=.+3.a'..'�.c '°s�'rray.a °saX�*3��tv�»-.unmiF 10108 CROSBY PLACE ���ac� �nma amwms� _ PORT SAINT LUCIE, FL 34986 4— General Notes: L . NI 1. The Legal Description used to perform this survey was supplied by ® others. This survey does not determine or is not to imply ownership. C T' 2. This survey only shows above ground improvements. Underground A utilities, footings, or encroachments are not located on this survey map, j 3. If there is a septic tank, well, or drain field on this survey, the location ® of such items was shown to us by others and the information was not I verified. 0,. 4. Examination of the abstract of title will have to be made to determine N S recorded instruments, if any, effect this property. The lands shown herein - C were not abstracted for easement or other recorded encumbrances not M ;R A shown on the plat. 5. Wall ties are done to the face of the wall. 1` t+� 6. Fence ownership is not determined. t,P; 7. Bearings referenced to line noted B.R. t Sy ,Ail i� � 8. Dimensions shown are platted and measured unless otherwise /j' {] <YN C Af. /� 1 ii ! c]dl +ek P n.a.a 8:261 NrVECq.la�wry Shown. Ai>35:5t 1 'S-Ow !_.c;SV li .'Yi51:Lfi'i£3 :s.,.f 3 vHY'vs i T..':.�L.-'R v^.{..Q;'„4i :9il -` 4 No identification found on property comers unless noted. CommdnitylNumber UNINCORPORATEDI 120285 10. Not valid unless sealed with the signing surveyors embossed seal. 11. Boundary survey means a drawing and/or graphic representation of Panel Number: 0275 the survey work performed in the field, could be drawn at a shown scale Suffix: and/or not to scale. 12. Elevations if shown are based upon NGVD 1929 unless otherv�iise Date of Firm Index: noted.Flood Zone: X 3. This is a BOUNDARY SURVEY unless otherwise noted. This survey is exclusive for the use of the parties to whom it is Base Flood Elevation: N/A14. certified. The certifications do not extend to any unnamed parties. Date of Field Work: 2/9/2011 iE_'WAAcr Date of Completion: 2/11/2011 Ri 23 .... 233"d�.t .�rc Certified To. D�SM NIG AMP LLA`T RSA AMPA(N 11M-I AN� t� NG $ " ,,.Certified TITLE INSURANCE COMPANY, SEACOAST NATIONAL BAN}5.,. (ts'sucCesso�s,and1,massigns=as their -interest mayappear L gal Descript o ALL dF T 64, A R HE LA P D THE E a S INS; RECORDED IN PLAT BOOK 38, PAGE(S) 2, 2A THROUGH 2C, PUBLIC RECORDS OF ST LUCiE COiJNTY; F'Li0`RtDA, PRINTING INSTRUCTIONS: While viewing the survey in any Acrobat Reader, select the File Drop -down and select "Print" Select a color printer, if available, or at least one with 8.5" x 14" paper. Select ALL for Print Range, and the # of copies you would like to print out. Under the "Page Scaling" please make sure you have selected "None." Do not check the "Auto Rotate and Center" button. Check the "Choose Paper size by PDT ,,checkbox. Click OK to Print. D Survey: A-20266 Page 2 of 2 Not valid without all pages. 2x8 SMB 2x8 SMB 2x8 SMB 2x8 SMB Lx0 •71VIa j/V DESIGN CRITERIA -2010 F.B.0 -PER ASCE7-10 -WIND ZONE=150 MPH -EXP B -CATEGORYI - APPLED UNIT LOADS, COMPONENT DETAILS AND FASTENING REQUIRMENTS AS PER THE ATTACHED 2010 AAF DESIGN SPECIFICATIONS. APPLICABLE DE I AILS ARE MARKED AS SHOWN AND ARE TO BE PART OF THE SITE SPECIFIED DESIGN CRITERIA FOR FABRICATION AND INSTALLATION. BUS: 561-753-7734, FAX:,561-753-7634 '3269 SW.42-AVE,,PALM-CITY; FL34990 -EMAIL floridascreenbuilders@comcastnet 9NESSITE iloridascreeribuilders.cam -STATE1-ICENSE:; CB C1254009 k5�"S�UPEIR � � ELEV'A' ELEV'A' GUTTER io m io N i N EXISTING COVERED PORCI I 2x3 (TYP) L-------------------------- N b" SUPER GU 1 1 ER in 2x3 (TYP) r; IN N � m tD n M jn 2x3 (TYP) ~ in Ncc o V) UJ V) ul fn to N ca m N ••N N N N N N N N V 2x3 (TYP) N n N 2x3 (TYP) 5'-8%° 3" O C�7 m W _= rTv v 17 rn co So m O Z —10 y a n m y m F 2 R zffvT b ss% i CA 2x3 (TYP) 3.3 TYP o /11 2x3 YP \ M M Iq U) mi U) to N ca U) co[a U) ,}^� to • y co ul N N N �% N N N N N N N 2x3 (TYP) .S "\•\ . �... C m EXISTING CONCRETEPATIO W/-FTG'S 2x3 2x3 2x8 SMB 2x8 SMB ULIL 2x8 SMB DFTAII. NOTFR1 COLOR: BRONZ€p)y ROOF SCREEN:18/14 1€_� WALL SCREEN: 18/14 � sfi- DOMENIC CAMPONELLA 101D8 CRO81BYPL PSL, FL'34986 518-.368=9971