HomeMy WebLinkAboutSUBMITTED PAPERS2F807FOkeechobee kd
(772)461-0729
. rrrr FL 34447
Permit Number:
J St. Lucie County
1� Building & Zoning Department
L3 - 2300 Virginia Avenue SCANNED
Fort Pierce, FL 34982
772-462-1553 BY
St. Lucie
APPLICATION FOR REPLACEMENT OF County
WINllOWS, SKYLIGHTS, DOORS & OVERHEAD GARAGE DOORS
SEE REVERSE SIDE FOR INSTRUCTIONS DATE:
1. LOCATION/SITE ADDRESS: 5 0 - 1 S J
2. PARCEL ID NUMBER: cQL4,a _I - qq I - 666 2 - 6 66 — a
3. DESCRIPTION OF PROJECT OR WORK ACTIVITY: / O ;7gnq& d dW r �' � U ✓�''�
CO 6•
4. TYPE OF STRUCTURE: SFR--3� MOBILE HOME OTHER
5. OWNERS INFORMATION 6.
Name: M ae14S Job A I0 lara L
Address: 3&S-i s a.SA S�
City: ��e_ rState:
Zip: InI81 Phone: 2)Q00��33y
CONTRACTOR'S INFORMATION
FL Reg/Cert #:
County Cert Sa?
#: /�
BusinessName: 4�a�0k,- TDB Sg ,r . e
ff
Windows, Swing Doors,
Skylights, Fixed Glass
I
Opening Design Pressure
A.S.C.E - 7
Design
Pressure
Product
Manufacture
'Model #
Method of Attachment #
Florida Product Approval #
120 mph
1130 mph
1140 mph
_
Windows & Skylights
Exposure B
Exposure C
Overhead Garage Doors
< 30' - F.B.C. Table 1609.6 (1) + 1609.6 (2)
B- Size Uelt1-
C- Size
1.
VALUE OF CONSTRUCTION: $ 1'151D J FEES DUE:
RECEIPT:
OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in
compliance with all applicable laws regulating shuction and zon'n .
4C1. P P Al-�
PRINT QUALIFIERS/OWNERS NAME SIGNAT E OF QUALIFIER/OWNER
STATE OF FLORIDA, COUNTY OF _ r p � � p J,�
ACKNOWLEDGED BEFORE ME THIS DAY( � , 20-a, BY jet � �-`'d7 klWHO IS PERSONAL L KNOWN TO ME OR O
HAS PRODUCED _ AS IDE ICAT ON.
V d �-►V7-m
fill
NATURE OF NOTARY YPE OR PRINT NAME OF NOTARY i nERINE V, ROgMAX
MY COMMISSION 0 FF04QM
TITLE: NOTARY PUBLIC COMMISSION NUMBER EXPIM'July 4' 2017
Property Appraiser - St.Lucie County, FL
i
Jose A Macias Record: 1 of 1
Property Identification
Site Address:
3659 S 25th St
Secrrown/Range:
29 :35S :40E
Map ID:
24/29S
Zoning:
AR-1
Ownership and Mailing
Owner:
Jose A Macias Clara L Macias
Address:
3659 S 25th St
Fort Pierce FL 34981-5107
Sales Information
Date
Price Code
Deed
1/21/1991
112500 00
WD
7/1/1988
0 01
CV
6/1/1987
0 01
CV
11/1/1986
0 01
CV
10/1/1984
85000 00
CV
'uLe6,�q?ta.:p
t4i!a,eoD.. "
PD135G
Page 1 of 1
PROPERTY RECORD CARD
«Prey Next» Spec.Assmnt Taxes Exemptions
Permits Home Print
ParcellD:
2429-441-0002-000-2
CIE 0
Account#:
32667
yam%
i
Use Type:
SF Res
77—a'<
City/Cnty:
Saint Lucie County
Legal Description
29 35 40 S 110 FT OF N 385 FT OFSE 1/4 OF SE 1/4 LYG E OF CANAL #29-LESS E 55
FT- (1.65 AC) (OR 724-
More...
Assessment 2013 Total Land and Building
Book/Page
2013 TRIM: 128200 Land Value: 53200 Acres:
1.65
0724 / 0701
Assessed: 121740 Building Value: 75000
0601 / 1582
Ag.Credit: 0 Finished Area: 1740 SgFt
0550 / 1741
Exempt: 50000
0521 / 1161
Taxable: 71740
0445 / 1809
Taxes: 1634.32
BUILDING INFORMATION
Exterior Features
View:
RoofCover:
TG - Tar & Gravel
RoofStruct:
GA - Gable
ExtType:
HD+ - HD+
YearBlt:
1965
Frame:
Grade:
D+ - D+
EffYrBlt:
1980
PrimeWall:
BP - Conc Block
StoryHght:
0010 - 1 Story
No.Units:
1
SecWall:
Interior Features
BedRooms:
3
Electric:
MX - MAXIMUM
PrmintWall:
PF - PF
FullBath:
2
HeatType:
FHA - FrcdHotAir
AvgHt/FI:
STD
1/2Bath:
0
HeatFuel:
ELEC - Electric
Prm.Flors:
HW - Hardwood
%A/C:
100
%Heated:
100
%Sprinkled:
0
Special Features and Yard
Items
Land Information
Type
Y/S city.
Units Qual.
Cond.
YrBlt.
No. Use Type
Type
Measure
SWAV - RES POOL AVG Y 1
0000000400 AV
AV
1987
1 0100-SF Res
215 -Front Ft
110
PA01 - POOL DK-AVG
Y 1
0000000350 AV
AV
1987
2 0100-SF Res
563 -Acres
1.15
SDSF - SITE DEV S-F
Y 1
1 AV
AV
2001
THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED.
Depth
200
http://www.paslc.org/paslc/prc.asp?prclid=242944100020002
9/4/2013
Florida Building Code Online
Page I of 1
RPR.HbME 1l96UT i58PR 68pR 61V1910M9 COHTA6TDRPA
BCIS Home ; Log In I User Registration I Hot Topics 1 Submit Surcharge I Stats & Facts j Publications I FBC Staff ; BCIS Site Map Links i Search
:.. ,Product Approval
USER: Public User
# :r•�`xi
Product Approval Menu > Product or Aoolication Search > Application List
:h Criteria
Version
:ation Type
ory
:ation Status
2010 FL#
ALL
ALL
ALL
duality Assurance Entity ALL
'roduct Model, Number or Name ALL
approved for use in HVHZ ALL
mpact Resistant ALL
)ther ALL
Search Results - Applications
Product Manufacturer
Subcategory
Compliance Method
Quality Assurance Entity Contract Expired
Product Description
Approved for use outside HVHZ
Design Pressure
I-10*
15279
ALL
ALL
ALL
ALL
ALL
ALL
ALL
FL#
Tvoe
Manufacturer IValidated
By
Status
FL15279-R1
Revision
Clopay Building Products Company
Gary Pfuehler
Approved
History
Category: Exterior Doors
(513) 519-6566
Subcategory: Sectional Exterior Door Assemblies
I*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
Contact Us :: 1940 North Monroe Street. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send
electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant
to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email
address If they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you
do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if
you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
= FORM 19 22
8@cUr1kA1l;T1k cV
i
http://floridabuilding.org/pr/pi_app_lst.aspx 9/4/2013
Florida Building Code Online
Page 1 of 6
Florida Depaltmelltof BCIS Home i Log In I User Registration I Hot Topics 1 Submit Surcharge I Stats & Facts j Publications I FBC Staff BCIS Site Map Links I Search
Busines
Professi I *'"USER: Product Approval
Public User
Regulation
i. imiagmsomProduct Approval Menu > Product or Application Search > Application List > Application Detail
FL #
FL15279-RI
Application Type
Revision
Code Version
2010
Application Status
Approved
*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified
by the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Certification Agency
Validated By
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Clopay Building Products Company
8585 Duke Blvd.
Mason, OH 45040
(513) 770-6062
mwesterfield@clopay.com
Scott Hamilton
shamilton@clopay.com
Exterior Doors
Sectional Exterior Door Assemblies
Certification Mark or Listing
Intertek Testing Services NA Inc. - ETL/Warnock Hersey
Gary Pfuehler
It'] Validation Checklist - Hardcopy Received
Standard
Year
ANSI/DASMA 108
2005
ANSI/DASMA 115
2005
ASTM E1886
2002
ASTM E1996
2002
ASTM E330
2002
Florida Licensed Professional Engineer or Architect
FL15279 R1 Eauiv 20120306 - FBC - DASMA 115 eauiv.Ddf
http://floridabuilding. orglprlpr_app_dtl. aspx?param=wGEVXQwtDgv3yV VKJZ 1 QRAbbA5BZkl9 l GYlne%2fwb l l7x%2bh7l3 3 oiuA... 9/4/2013
Florida Building Code Online Page 2 of 6
Product Approval Method Method 1 Option A
Date Submitted 06/18/2012
Date Validated 06/21/2012
Date Pending FBC Approval
Date Approved 07/02/2012
Summary of Products
Go to Page Div Page 7 / 7
FL #
IlModel, Number or Name
IDescription
15279.121
121 W6-18 PAN-21`443: G4S, GS4,
Gallery/Artistry/Expressions: Steel Pan (min. 24 ga.) 16'4"
GD4S, GR4S, G4SV, GS4V, GD4SV,
to 18'2" wide WINDCODE@ W6 Garage Door
GR4SV, E4S, ED4S, E4SV, ED4SV,
SS4, AR4S, SS4V, AR4SV
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: No
FL15279 Rl C CAC Letter with proof of contract and
proof of inspection.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
FL15279 RI C CAC W6 Listino Intertek.pdf
Design Pressure: +37 PSF/-39 PSF
Quality Assurance Contract Expiration Date
Other: Solid doors (no standard glazing) are impact-
05/21/2028
resistant (large missile impact).
Installation Instructions
FL15279 R1 II 103406-A-Rev06.odf
Verified By: Intertek Testing Services NA Inc. -
ETL/Warnock Hersey
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
15279.122
122 W6-18 PAN-2F443: G4S, GS4,
Gallery/Artistry/Expressions: Steel Pan (min. 24 ga.) 16'4"
GD4S, GR4S, G4SV, GS4V, GD4SV,
to 18'2" wide WINDCODE@ W6 Garage Door
GR4SV, E4S, ED4S, E4SV, ED4SV,
SS4, AR4S, SS4V, AR4SV
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: No
FL15279 R1 C CAC Letter with proof of contract and
proof of inspection.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: No
FL15279 Rl C CAC W6 Listing Intertek.pdf
Design Pressure: +37 PSF/-39 PSF
Quality Assurance Contract Expiration Date
Other: The standard glazing available for this product
05/21/2028
meets the wind load requirements of the building code but
Installation Instructions
DOES NOT meet the impact resistant requirement for
FL15279 Rl II 103406-B-Rev06.pdf
windborne debris regions.
Verified By: Intertek Testing Services NA Inc. -
ETL/Warnock Hersey
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
15279.123 123 W4-09 DSIE-1F171: 4300,
Double -skin Insulated EPS (exterior skin 27 ga. min.;
4301, 4310, 4400, 4401, HDG,
interior skin 27 ga. min.) Single -Car (up to 9'0" wide)
HDGL, HDGF, 66, 66G, 67, 67G,
WINDCODE@ W4 Garage Door
68, SP200, SF200, SE200, 6200,
6201, 6203
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: No
FL15279 Rl C CAC Letter with proof of contract and
Approved for use outside HVHZ: Yes
proof of inspection.pdf
Impact Resistant: Yes
FL15279 Rl C CAC W4 Listing Intertek.odf
Design Pressure: +28 PSF/-29 PSF
Quality Assurance Contract Expiration Date
Other: Solid doors (no glazing) or doors with optional
05/21/2028
impact -resistant glazing are impact -resistant (large missile
Installation Instructions
impact).
FL15279 R1 II 101652-A-Revll.pdf
Verified By: Intertek Testing Services NA Inc. -
ETL/Warnock Hersey
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
15279.124 124 W4-16 DSIE-1F171: 4300,
Double -skin Insulated EPS (exterior skin 27 ga, min.;
http://floridabuilding.orglprlpr_app_dtl.aspx?param=wGEVXQwtDgv3yV VKJZ 1 QRAbbA5BZkl91 GYlne%2fwb l l7x%2bh7l33 oiuA... 9/4/2013
Florida Building Code Online
Page 3 of 6
4301, 4310, 4400, 4401, HDG,
HDGL, HDGF, 66, 66G, 67, 67G,
68, SP200, SF200, SE200, 6200,
6201, 6203
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +25.5 PSF/-25.5 PSF
Other: Solid doors (no glazing) or doors with optional
impact -resistant glazing are impact -resistant (large missile
impact).
nterior skin 27 ga. min.) Double -Car (97' to 16'0" wide)
NINDCODE@ W4 Garage Door
Certification Agency Certificate
FL15279 R1 C CAC Letter with proof of contract and
FLIS279 R1 C CAC W4 Listing Intertek.pdf
Quality Assurance Contract Expiration Date
05/21/2028
Installation Instructions
FL15279 R1 II 101481-A-Rev13.Ddf
Verified By: Intertek Testing Services NA Inc. -
=TL/Warnock Hersey
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third
15279.125
125 W4-18 DSIE-11`171: 4300,
Double -skin Insulated EPS (exterior skin 27 ga, min.;
4301, 4310, 4400, 4401, HDG,
interior skin 27 ga. min.) 16'2" to 18'0" wide WINDCODE®
HDGL, HDGF, 66, 66G, 67, 67G,
W4 Garage Door
68, SP200, SF200, SE200, 6200,
6201, 6203
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: No
FL15279 R1 C CAC Letter with proof of contract and
Approved for use outside HVHZ: Yes
proof of inspection.pdf
Impact Resistant: Yes
FL15279 R1 C CAC W4 Listing Intertek.pdf
Design Pressure: +25 PSF/-25 PSF
Quality Assurance Contract Expiration Date
Other: Solid doors (no glazing) or doors with optional
05/21/2028
impact -resistant glazing are impact -resistant (large missile
Installation Instructions
impact).
FL15279 R1 II 101247-A-Rev19.Ddf
Verified By: Intertek Testing Services NA Inc. -
ETL/Warnock Hersey
Created by Independent Third Party:
Evaluation Reports
Created bvIndependentThird Partv:
15279.126 126 W4-09 PAN-21`151: 73, 1500,
75, 190, 84A, 94, 76, 42, 48, 55,
42B, 48B, 55S, 4RST, 6RST, 4RSF,
6RSF, 2RST, GD5S, GD5SV, GR5S,
GR5SV, AR5S, AR5SV, ED5S,
ED5SV
_imits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +25 PSF/-32 PSF
Other: Solid doors (no glazing) or doors with optional
mpact-resistant glazing are impact -resistant (large missile
mpact).
!el Pan (min. 25 ga.) Single -Car (up to 9'0" wide)
NDCODE@ W4 Garage Door
Certification Agency Certificate
FL15279 R1 C CAC Letter with proof of contract and
FL15279 R1 C CAC W4 Listing Intertek.pdf
Quality Assurance Contract Expiration Date
05/21/2028
Installation Instructions
FL15279 R1 II 300159-A-Rev16.odf
Verified By: Intertek Testing Services NA Inc. -
ETL/Warnock Hersey
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
15279.127 127 W4-16 PAN-21`153: 73, 1500, JISteel Pan (min. 25 ga.) Double -Car (9'2" to 16'0" wide)
75, 190, 84A, 94, 42, 48, 55, WINDCODE@ W4 Garage Door
4RST, 6RST, 4RSF, 6RSF, GDSS,
GD5SV, GR5S, GR5SV, AR5S,
AR5SV, ED5S, ED5SV
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +24 PSF/-24.5 PSF
Other: Solid doors (no glazing) or doors with optional
impact -resistant glazing are impact -resistant (large missile
impact).
Certification Agency Certificate
FL15279 R1 C CAC Letter with proof of contract and
FL15279 R1 C CAC W4 Listing Intertek.pdf
Quality Assurance Contract Expiration Date
05/21/2028
Installation Instructions
FL15279 R1 II 101711-A-Rev15.odf
Verified By: Intertek Testing Services NA Inc.
ETL/Warnock Hersey
Created by Independent Third Party:
Evaluation Reports
http://floridabuilding.orglprlpr_app_dtl.aspx?param=wGEVXQwtDgv3yV VKJZ 1 QRAbbA5BZkl91 GYlne%2fwb l l7x%2bh7l33 oiuA... 9/4/2013
Florida Building Code Online
Created bv Independent Third Pa
Page 4 of 6
15279.128
128 W4-18 PAN-2F153: 73, 1500,
Steel Pan (min. 25 ga.) 16'2" to 18'0" wide WINDCODE@
75, 190, 84A, 94, 42, 48, 55, 42B,
W4 Garage Door
48B, 55S, 4RST, 6RST, 4RSF,
6RSF, GD5S, GD5SV, GR5S,
GR5SV, AR5S, AR5SV, ED5S,
ED5SV
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: No
FL15279 R1 C CAC Letter with proof of contract and
Approved for use outside HVHZ: Yes
proof of inspection.pdf
Impact Resistant: Yes
FL15279 Rl C CAC W4 Listing Intertek.pdf
Design Pressure: +25 PSF/-25 PSF
Quality Assurance Contract Expiration Date
Other: Solid doors (no glazing) or doors with optional
05/21/2028
impact -resistant glazing are impact -resistant (large missile
Installation Instructions
impact).
FL15279 R1 II 101312-A-Revl4.pdf
Verified By: Intertek Testing Services NA Inc. -
ETL/Warnock Hersey
Created by Independent Third Party:
Evaluation Reports
Created bv Independent Third Party:
15279.129 129 W4-09 DSIE-11`471: GD2SP, Gallery/Artistry/Expressions: Double -skin Insulated EPS
GR2SP, GD2LP, GR2LP, AR2SP, (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single-
AR2LP, ED2SP, ED2LP Car (up to 9'0" wide) WINDCODE@ W4 Garaqe Door
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +28 PSF/-29 PSF
Other: Solid doors (no glazing) are impact -resistant (large
missile impact).
Certification Agency Certificate
FL15279 Rl C CAC Letter with proof of contract and
FL15279 R1 C CAC W4 Listing Intertek.pdf
Quality Assurance Contract Expiration Date
05/21/2028
Installation Instructions
FL15279 R1 II 103969-A-Rev02.pdf
Verified By: Intertek Testing Services NA Inc. -
ETL/Warnock Hersey
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Partv:
15279.130
130 W4-09 PAN-2F441: G4S, GS4,
Gallery/Artistry/Expresslons: Steel Pan (min. 24 ga.)
G4L, GL4, GD4S, GD4L, GR4S,
Single -Car (up to 9'0" wide) WINDCODE@ W4 Garage Door
GR4L, G4SV, GS4V, G4LV, GL4V,
GD4SV, GD4LV, GR4SV, GR4LV,
E4S, E4L, ED4S, ED4L, E4SV,
E4LV, ED4SV, ED4LV, SS4, SL4,
AR4S, AR4L, SS4V, SL4V, AR4SV,
AR4LV
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: No
FL15279 R1 C CAC Letter with proof of contract and
proof of insgection.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
FL15279 R1 C CAC W4 Listing Intertek.pdf
Design Pressure: +25 PSF/-32 PSF
Quality Assurance Contract Expiration Date
Other: Solid doors (no glazing) are impact -resistant (large
05/21/2028
missile impact).
Installation Instructions
FL15279 R1 II 103486-A-RevOS.Ddf
Verified By: Intertek Testing Services NA Inc. -
ETL/Warnock Hersey
Created by Independent Third Party:
11
Evaluation Reports
5279.131 131 W4-16 DSIE-1F471: GD2SP,
GR2SP, GD21_P, GR21_P, AR2SP,
��AR21_P, ED2SP, ED2LP
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +25.5 PSF/-25.5 PSF
Other: Solid doors (no glazing) are impact -resistant (large
missile impact).
Created by Independent Third
Sallery/Artistry/Expressions: Double -skin Insulated EPS
;exterior skin 27 ga. min.; interior skin 27 ga. min.)
double -Car (9'2" up to 16'0" wide) WINDCODE@ W4
3arage Door
'ertification Agency Certificate
FL15279 Rl C CAC Letter with proof of contract and
FL15279 Rl C CAC W4 Listinq Intertek.pdf
2uality Assurance Contract Expiration Date
05/21/2028
Installation Instructions
FL15279 R1 II 104029-A-Rev03.Ddf
Verified By: Intertek Testing Services NA Inc. -
:TL/Warnock Hersey
http://floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZl QRAbbA5BZkl9l GYlne%2fwb ll7x%2bh7l33oiuA... 9/4/2013
Florida Building Code Online Page 5 of 6
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
15279.132
132 W4-16 PAN-2F443: G4S, GS4,
Gallery/Artistry/Expressions: Steel Pan (min. 24 ga.)
GD4S, GR4S, G4SV, GS4V, GD4SV,
Double -Car (9'2" to 16'0" wide) WINDCODE@ W4 Garage
GR4SV, E4S, ED4S, E4SV, ED4SV,
Door
SS4, AR4S, SS4V, AR4SV
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: No
FL15279 R1 C CAC Letter with proof of contract and
proof of inspection.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
FL15279 R1 C CAC W4 Listing Intertek.pdf
Design Pressure: +25 PSF/-25 PSF
Quality Assurance Contract Expiration Date
Other: Solid doors (no glazing) are impact -resistant (large
05/21/2028
missile impact).
Installation Instructions
FL15279 R1 II 103454-A-Rev06.pdf
Verified By: Intertek Testing Services NA Inc. -
ETL/Warnock Hersey
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
15279.133
133 W4-16 PAN-2F446: G4L, GL4,
Gallery/Artistry/Expressions: Steel Pan (min. 24 ga.)
GD4L, GR4L, G41_V, GL4V, GD41_V,
Double -Car (9'2" to 16'0" wide) WINDCODE@ W4 Garage
GR4LV, E4L, ED4L, E4LV, ED4LV,
Door
SL4, AR4L, SL4V, AR4LV
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: No
FL15279 R1 C CAC Letter with proof of contract and
Approved for use outside HVHZ: Yes
proof of inspection.pdf
Impact Resistant: Yes
FL15279 R1 C CAC W4 Listing Intertek.odf
Design Pressure: +25 PSF/-25 PSF
Quality Assurance Contract Expiration Date
Other: Solid doors (no glazing) are impact -resistant (large
05/21/2028
missile impact).
Installation Instructions
FL15279 R1 II 103454-A-Rev06.Ddf
Verified By: Intertek Testing Services NA Inc. -
ETL/Warnock Hersey
Created by Independent Third Party:
Evaluation Reports
1.1 Created by Independent Third Party:
15279.134
134 W4-18 PAN-2F443: G4S, GS4,
Gallery/Artistry/Expressions: Steel Pan (min. 24 ga.) 16'2"
GD4S, GR4S, G4SV, GS4V, GD4SV,
to 18'0" wide WINDCODE@ W4 Garage Door
GR4SV, E4S, ED4S, E4SV, ED4SV,
SS4, AR4S, SS4V, AR4SV
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: No
FL15279 R1 C CAC Letter with proof of contract and
proof of inspection.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
FL15279 R1 C CAC W4 Listing Intertek.pdf
Design Pressure: +25 PSF/-25 PSF
Quality Assurance Contract Expiration Date
Other: Solid doors (no glazing) are impact -resistant (large
05/21/2028
missile impact).
Installation Instructions
FL15279 R1 II 103498-A-Rev05.pdf
Verified By: Intertek Testing Services NA Inc. -
ETL/Warnock Hersey
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
15279,135
135 W4-18 PAN-2F446: G4L, GL4,
Gallery/Artistry/Expressions: Steel Pan (min. 24 ga.) 16'2"
GD4L, GR4L, G41_V, GL4V, GD41_V,
to 18'0" wide WINDCODE@ W4 Garage Door
GR4LV, E4L, ED4L, E4LV, ED4LV,
SL4, AR4L, SL4V, AR4LV
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: No
FL15279 R1 C CAC Letter with proof of contract and
proof of inspection.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
FL15279 R1 C CAC W4 Listing Intertek.pdf
Design Pressure: +25 PSF/-25 PSF
Quality Assurance Contract Expiration Date
Other: Solid doors (no glazing) are impact -resistant (large
05/21/2028
missile impact).
Installation Instructions
FL15279 R1 II 103498-A-Rev05.Ddf
Verified By: Intertek Testing Services NA Inc. -
ETL/Warnock Hersey
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
http://floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgv3yV VKJZ 1 QRAbbA5BZkl91 GYlne%2fwb l l7x%2bh7l33oiuA... 9/4/2013
Florida Building Code Online Page 6 of 6
f
Go to Page 0 Page 7 / 7 0 0
Back Next
Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send
electronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant
to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email
address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you
do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if
you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
f ® c-0� k M
F
re= efi�C�rF�
http://floridabuilding.orglprlpr_app_dtl.aspx?param=wGEVXQwtDgv3yV VKJZ 1 QRAbbA5BZkl9l GYlne%2fwb l l7x%2bh7l33oiuA... 9/4/2013
DIM HE[GM
• - MODEL 4F IS FLUSH
TARRIATE IOIff' RALffO PANEL
EIOOSS DOERS
F®ELS
a CA
a OA DS
CLOPAT
T.ALLEW
GD5S,
GRSS
GTmV,
GRSSv
HOLIES
•ARTISTRY•
Arm
ARSSV
T� HOUSE,
EIDS
EDAV
I SIOTf PAEL I
. y
>� vD m DTnJ s SHEET 1 OF 2 REv
9z m no• 1 09 11/30/07 AOOED E1(IEKOED IETOFIIS, COYBBED
wv m uKn 2 10 OB/08/08 ADDED 1 42A 488, 555
12TU' m I]'IR' 3
uv m uw 4 11 10/21/05 ADDED I 1 4F
12 8/2OD9 ADDED •CARRIAGE HOUSE' EMBOSS DO
1 13 B/2010 UPDATED MODEL TABLE
14 1/2D12 REVISED MAD SPEED TABLE FOR ASCI
OPTIONAL GLAZING MAY BE STANDARD OR IMPACT 15 4/2012 ADDED IMPACT RESISTANT oFnON.
RESISTANT GLAZING. SEE SECTION B-B FOR
DETAILS.
Blast (SEE TABLE FOR OI'0 MAX. STANDARD SIZE IS 42-1/2k16'. IMPACT
RRDUEO W/ 7p0-L-E R0P A eo1 1 RESISTANT GLAZING IS 2D1-55/8k14-1/8-.
y A WE"TE C��D U-01B5 IN R-1-S-1ECIIO QAT","l N,
ONE U�VS ON NEXT
SEP:fON. ETTa
Ill�llill�lllll�lllll��lllll�lllll�lllll��llll���:1�
—,�--,—T� I'
ICI ICI ICI I��I�I�I ICI ICI ICI
`OF Anon TEARS
1 •CIASSMA 3 RNSED-MUld SUam •GVLdAfE HOUSE
SHORT RAID-0ARL IS ALSO APPROVED.
E14.5/5' SHEET
E41L SCREWS
t/4b/4 sFtF
LVRID StlRMS O
u u FYn IMfFS 1e a EOEPrvmA
Wnv w �,�Tc rHee
—� A ` OPnONAL OUISEE NETFD =K POSOION
. DOOR IMM - le•-O'
D�lab15
SEE SHEET TWO FOR
IMPACT RESISTANT CONSTRUCTION DETAIL "A"
AND STANDARD CONSTRUCT DETAIL "B";
TRACK AND JAMB DETAILS.
NCINEER: HARK WESLERFIEID. P.E
P.E 148495.
12M 513
1 20 OA WL END ST ES ATOQm m DOOR
—EOCEOiC srs1EMMM&}
_ Pu
ver "w mrl
i
oi� __
EAx
SHIP LAP JOINTS.-
1/ DENSITY POLYSTYRENE FOAM INSULATION
1-5/16 THICK WITH VINYL HAIRCELL
BACKER (INSULATED MODELS ONLY)
25 GA MIN. GALV. STEEL SKIN
WITH A BAKED —ON PRIMER,
AND A BAKED —ON POLYESTER
TOP COAT APPLIED TO BOTH
SIDES OF STEEL. SKIN.
TS W PF315 OR F)REOS THE OESCI U FOR ➢E
LLTa1OE IFEO SPFEnS USIED Imw ACCOIOFID m THE nnmA
suaDFn DDDE a nE FFRfOtvNN•L ®RdO c40E (MTin pN
AsOET-10) FOt 9E PDILwEc coFDOlorRs: 1) EEO®
ANY,OOF SIOR, MO Q iLSIMC M ACOOIOVAE Ofll ZOUC 31
At9/nt9M 101 SIZE-SPFOfC fMQ4Q1016 M A OUNEID
OE9011 AiS50NL MC pTA
O�'Ea O�RO�
MO
tiz
1>D
[AD
ffi
TATTY
),Gn
A.GO
1.0
a,c1
3
NTAH _ HE
F'9
US'I
a
IIS'
DF'
SECTION A —A (SIDE VIEW) 3- TALL U—BAR
20 GA GALV. STEEL
MIN. YEILD STRENGTH: 50 KSI
1THICK -d 3•
1_7/8.
rf: T
12 GA GALV. STEEL TOP
ROLLER BRACKET. EACH
BRACKET ATTACHED W/(4)
/14N5/8' SHEET METAL
SCREWS.
— 14 GA GALV. ROLLER HINGE
EACH HINGE FASTENED TO END
STILES WITH (4) /144/8'
SHEET METAL SCREWS AND (4)
1/4'T3/4' SELF TAPPING
\SCREWS. SEE VIEW 'B-.
`3' TALL N 20 GA. GALV. STEEL U—BARS IN
A 2-1-2-1 PATTERN (I.E. TWO U—BAR"
ON BOTTOM SECTION, ONE U—BAR ON NEXT
SECTION, ETC.). EACH U—BAR ATTACHED
WITH (2) 1/4k3/4- SELF TAPPING SCREWS
PER STILE LOCATION.
13 GA GALV. STEEL BOTTOM BRACKET.
ATTACHED WITH (2) /144/8- SHEET METAL SCREWS.
_ �IO MPC: PAN-2F153
pa y DATE. 1/3/97 DESC
8585 DUKE BLVD. DRAWN By,
Building Products MASON, OH 45040 JAC
C O m O n (513) 770-4800 OEO= BY, B
OOM O<PPOPR11mI An fthb R.. d. MWW
LPPROO VAL 15279
DESIGN LOADS: +24.0 PSF & —24.5 PSF
TEST LOADS: +36.0 PSF & —37.0 PSF
RATTING MAX DOER SIZE.
4 _1 16'0'W X 16'0'H
CLASSIC AND CH RP STEEL PAN
DOUBLE -CAR, 16'W +24/-24.5 PSF
O G MA®EW l Vm
101711 IBC
EMBOSS DOORS I DOOR FOCHT
- - MODEL 4F IS FLUSH
'CARRIAGE HOUSE' RAISED PANEL
OU El6S COO S
t®ELS
m GA
25 GA DS
CLDFAY
'GALJERR
GDSS,
DIM
GDSSV,
EASY
HO MET
'Mf6TRY'
ARS
ARAM
IDEALTARREAGE HOW
EIS
EDSSV
IMPACT RESISTANT ASSEMBLY DETAILS
DRAWING 101711-A
SECTION B-B (IMPACT -RESISTANT GLAZING OPTION)
�DEDv. tr
aPNIONEI DEELPAiIEE IwwnOSE HIGH BOND TAPE
SHAP-N NSERE. MO-EDI FRANC AND FXADEJ
IONT BCA¢
BELIE SAAANI
(BEIWE01 5M SON AND FRAE).
ONE 65E'O
i a® Ix E POEnTna1E .1 ro . NO,
(10) /D . 3/4' PAM IOU NNON E SCROSE
wFW.a
T16
THE IIPACr-PSISTANE
STANDARD ASSEMBLY DETAILS
DRAWING 101711-8
SECTION B-8 (NON -IMPACT RESISTANT GLAZING OPTION)
FROM FRAE THIN U.V. COMM ON OUTSIDE SURFACE
NOTE THAT FRONT FRWE 6 NNUMM THAN
IMPACr-RESSANf FRAME.
G
GAaB
MOVED 068E
*VYF
UTE RETARFR.
/GES/N• NYW NEAR SCREW.
�ANDARD ASSEMBLY CONSTRUCTION:
CON�U�ON:
OPf1a1NL 556E DSB OR 1 ACVR C UIER AVAE�nc
OPf10N1L ACRIML 6 PIASNOUTE OPTOC OR ACHE
CP APPROVED CC! PLASTIC N ACCORDANCE RAIN BC/EBC
2W.
THE ENDUE DOOR A40Blr INSTALLED N CDPLMNCE
WITH TH6 SECTION NESTS THE WIND LOAD REQUIREMENTS
OF RE FLp2M BOOM CODE OR NTE NATONAL
BUILDING CODE BUT �• EBI MEET THE OVACr
RESISTANT REDIIREIIONT FOR RimBOUE DEBR6 RESIGNS
(REF. OAPTER 16 N)C/BC).
O0Q FR"SHEET 2 OF 2
3/NI•Es UC SC%16 ON n'^CENfF16.E BIND` 1-
1-1/� =. fA9EA NRGUEBD. IAO
Smw MAY BE CGRNIE m (W NOI ISgr 70 PR0110E A Fl191
VOIACING SURFACE NOIRWNL JAMBS DO NOf 1RANSFEIi u110.
y�Mn ArrAOR-xr (C-00 �__ In s1MO 19 w. aNrnnc
6'EY SIFFE AMOIOR BWS ON m• CFNIFRS (GD00 P9 NIL CONpEflE)�-
IA9Di6 NGIAFD tW1M SLLEVE ANROIS
OR
1E4TER TAPCOII MOCK), ON tR DINERS REQUIRED
PSI IN. APOORL) OR G'
CENTERS (O-GO COIN IT O.D. ILLLSI NDT REGIILFD NIII IAPCOIS
NCNd6 WV BE CGADEIIARN (BUr IIOf REGARED W PROEIDE A FU/S1
HORNING SAPAC. HORQONTAL JIYBS 00 110E UmD.
ipTQ, REFER To DASMA TDS-101. A OfENSER DEDON
PROFESSIONAL RAT ASD BE EMPLODED TO APPROVE ALTERNATE EAs1EIFI6
AND/OR due mKINJUDMEL
PRFPARAOII eF AJ�
STOP NOADNG BY DOLL NSOWEA GO SLID
GEO YFLLDII PIES .RIB
m G 1NL MY. "IF3 7DO SERE
/ m G GILV. STEEL HIFR STILE
II I
7//16' ID. (ROUND D PIIDNID
i71S1E1� ((TIE PER ROLLDD
11 G GAV. INCE EIOU
TO STLES
BIN (4HFIGE E))~��� �/E• .
ZEAL 3CJFER4
14 G GLV. POLLEN HYE. EAOI HNCE
EASRRED To END STI S TINN (4)
SHEET MET& SCREWS AND
%4�ie7/%C SELF TAPPING SC EWS. (4)
2' 10 BALL SNOUT SUM STEEL ROLLER WON
STEEL OR NRLN THE
.NIBJNLBWBe1xIL1
sBGEIGn c-G
MM- THE DESGN OF THE SUPPORTING SIRWTURAL n8EXIS SMALL BE THE
fESPO1BBNIY OF THE PROFESSIONAL M RECORD FOR THE 13 O OR
SIRUCIUE AND N ACCORDANCE WON CURRENT BUBDW CODES FOR THE UM
LIM ON THE DRAWM
ENGINEER: MARK INEMEFfIE D.
Clopay
Building Products MMAASON UpFj 45040
C011113anY (513) 77D-48W
15279
DESCRIPTION
ON SHEET ONE.
MM TRACK CONFIGURATION
ABOVE THE DOOR OPENING
DOES NOT AFFECT THE WIND
LOAD RATING OF THIS DOOR.
RA T Of
HORMDNTA TRACK
DOOR iFA (O
TALLS AND IAOR
xv sm FLAG [RALTEf.
LHR TOP BRACKET
S1FNm W R700 .NAB WAIN
it-SEE'WOOD LAO SCRmmTiU(.KDOUBLE
DOUBLEHORQONUL
rTAD
LOW HEADROOM OPTION
. STEEL iiOt IIILGGI/YdI
STEELOC
iRYJQIi PR SOIL
3E
NEEDED.
DAVAAABE
DOORS OVER M TAIL
O' OAK 57FEL 1PACK
1w. 1HICIQE.4 LW' uN.
ikkMiE OTIE WN I AO WP MH ICK
S NOT W MIDI) 30' Olt
I
MM FOR DOORS OVER
'L• Ir-O• HwK V"
$ aCOIFIGIRMOSOUL NOT
SOUNOT
b EXCEED uAOAtY S•AOO
PROV CONSULT FICMW
FOR MORE OCTAL F ROD.
}Iz
I
DESIGN LOADS: +24.0 PSF & -24.5 PSF
TEST LOADS: +36.0 PSF & -37.0 PSF
�hCTURDli PRODUCT MPC: PAN-2F753 AD�LD4n RMiTG
NAK >mL slzE
DATE W 4 16'0'W x 16'0'H
1/3/97 N=WTZN CLASSIC AND CH RP STEEL PAN
DRAWN BY. JAC DOUBLE -CAR, 16'W +24/-24.5 PSF
C EOED BY, DRAVD6 -N'm I VM
MWW B 101711 BC