Loading...
HomeMy WebLinkAboutSUBMITTED PAPERS2F807FOkeechobee kd (772)461-0729 . rrrr FL 34447 Permit Number: J St. Lucie County 1� Building & Zoning Department L3 - 2300 Virginia Avenue SCANNED Fort Pierce, FL 34982 772-462-1553 BY St. Lucie APPLICATION FOR REPLACEMENT OF County WINllOWS, SKYLIGHTS, DOORS & OVERHEAD GARAGE DOORS SEE REVERSE SIDE FOR INSTRUCTIONS DATE: 1. LOCATION/SITE ADDRESS: 5 0 - 1 S J 2. PARCEL ID NUMBER: cQL4,a _I - qq I - 666 2 - 6 66 — a 3. DESCRIPTION OF PROJECT OR WORK ACTIVITY: / O ;7gnq& d dW r �' � U ✓�''� CO 6• 4. TYPE OF STRUCTURE: SFR--3� MOBILE HOME OTHER 5. OWNERS INFORMATION 6. Name: M ae14S Job A I0 lara L Address: 3&S-i s a.SA S� City: ��e_ rState: Zip: InI81 Phone: 2)Q00��33y CONTRACTOR'S INFORMATION FL Reg/Cert #: County Cert Sa? #: /� BusinessName: 4�a�0k,- TDB Sg ,r . e ff Windows, Swing Doors, Skylights, Fixed Glass I Opening Design Pressure A.S.C.E - 7 Design Pressure Product Manufacture 'Model # Method of Attachment # Florida Product Approval # 120 mph 1130 mph 1140 mph _ Windows & Skylights Exposure B Exposure C Overhead Garage Doors < 30' - F.B.C. Table 1609.6 (1) + 1609.6 (2) B- Size Uelt1- C- Size 1. VALUE OF CONSTRUCTION: $ 1'151D J FEES DUE: RECEIPT: OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in compliance with all applicable laws regulating shuction and zon'n . 4C1. P P Al-� PRINT QUALIFIERS/OWNERS NAME SIGNAT E OF QUALIFIER/OWNER STATE OF FLORIDA, COUNTY OF _ r p � � p J,� ACKNOWLEDGED BEFORE ME THIS DAY( � , 20-a, BY jet � �-`'d7 klWHO IS PERSONAL L KNOWN TO ME OR O HAS PRODUCED _ AS IDE ICAT ON. V d �-►V7-m fill NATURE OF NOTARY YPE OR PRINT NAME OF NOTARY i nERINE V, ROgMAX MY COMMISSION 0 FF04QM TITLE: NOTARY PUBLIC COMMISSION NUMBER EXPIM'July 4' 2017 Property Appraiser - St.Lucie County, FL i Jose A Macias Record: 1 of 1 Property Identification Site Address: 3659 S 25th St Secrrown/Range: 29 :35S :40E Map ID: 24/29S Zoning: AR-1 Ownership and Mailing Owner: Jose A Macias Clara L Macias Address: 3659 S 25th St Fort Pierce FL 34981-5107 Sales Information Date Price Code Deed 1/21/1991 112500 00 WD 7/1/1988 0 01 CV 6/1/1987 0 01 CV 11/1/1986 0 01 CV 10/1/1984 85000 00 CV 'uLe6,�q?ta.:p t4i!a,eoD.. " PD135G Page 1 of 1 PROPERTY RECORD CARD «Prey Next» Spec.Assmnt Taxes Exemptions Permits Home Print ParcellD: 2429-441-0002-000-2 CIE 0 Account#: 32667 yam% i Use Type: SF Res 77—a'< City/Cnty: Saint Lucie County Legal Description 29 35 40 S 110 FT OF N 385 FT OFSE 1/4 OF SE 1/4 LYG E OF CANAL #29-LESS E 55 FT- (1.65 AC) (OR 724- More... Assessment 2013 Total Land and Building Book/Page 2013 TRIM: 128200 Land Value: 53200 Acres: 1.65 0724 / 0701 Assessed: 121740 Building Value: 75000 0601 / 1582 Ag.Credit: 0 Finished Area: 1740 SgFt 0550 / 1741 Exempt: 50000 0521 / 1161 Taxable: 71740 0445 / 1809 Taxes: 1634.32 BUILDING INFORMATION Exterior Features View: RoofCover: TG - Tar & Gravel RoofStruct: GA - Gable ExtType: HD+ - HD+ YearBlt: 1965 Frame: Grade: D+ - D+ EffYrBlt: 1980 PrimeWall: BP - Conc Block StoryHght: 0010 - 1 Story No.Units: 1 SecWall: Interior Features BedRooms: 3 Electric: MX - MAXIMUM PrmintWall: PF - PF FullBath: 2 HeatType: FHA - FrcdHotAir AvgHt/FI: STD 1/2Bath: 0 HeatFuel: ELEC - Electric Prm.Flors: HW - Hardwood %A/C: 100 %Heated: 100 %Sprinkled: 0 Special Features and Yard Items Land Information Type Y/S city. Units Qual. Cond. YrBlt. No. Use Type Type Measure SWAV - RES POOL AVG Y 1 0000000400 AV AV 1987 1 0100-SF Res 215 -Front Ft 110 PA01 - POOL DK-AVG Y 1 0000000350 AV AV 1987 2 0100-SF Res 563 -Acres 1.15 SDSF - SITE DEV S-F Y 1 1 AV AV 2001 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED. Depth 200 http://www.paslc.org/paslc/prc.asp?prclid=242944100020002 9/4/2013 Florida Building Code Online Page I of 1 RPR.HbME 1l96UT i58PR 68pR 61V1910M9 COHTA6TDRPA BCIS Home ; Log In I User Registration I Hot Topics 1 Submit Surcharge I Stats & Facts j Publications I FBC Staff ; BCIS Site Map Links i Search :.. ,Product Approval USER: Public User # :r•�`xi Product Approval Menu > Product or Aoolication Search > Application List :h Criteria Version :ation Type ory :ation Status 2010 FL# ALL ALL ALL duality Assurance Entity ALL 'roduct Model, Number or Name ALL approved for use in HVHZ ALL mpact Resistant ALL )ther ALL Search Results - Applications Product Manufacturer Subcategory Compliance Method Quality Assurance Entity Contract Expired Product Description Approved for use outside HVHZ Design Pressure I-10* 15279 ALL ALL ALL ALL ALL ALL ALL FL# Tvoe Manufacturer IValidated By Status FL15279-R1 Revision Clopay Building Products Company Gary Pfuehler Approved History Category: Exterior Doors (513) 519-6566 Subcategory: Sectional Exterior Door Assemblies I*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Contact Us :: 1940 North Monroe Street. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: = FORM 19 22 8@cUr1kA1l;T1k cV i http://floridabuilding.org/pr/pi_app_lst.aspx 9/4/2013 Florida Building Code Online Page 1 of 6 Florida Depaltmelltof BCIS Home i Log In I User Registration I Hot Topics 1 Submit Surcharge I Stats & Facts j Publications I FBC Staff BCIS Site Map Links I Search Busines Professi I *'"USER: Product Approval Public User Regulation i. imiagmsomProduct Approval Menu > Product or Application Search > Application List > Application Detail FL # FL15279-RI Application Type Revision Code Version 2010 Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Certification Agency Validated By Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Clopay Building Products Company 8585 Duke Blvd. Mason, OH 45040 (513) 770-6062 mwesterfield@clopay.com Scott Hamilton shamilton@clopay.com Exterior Doors Sectional Exterior Door Assemblies Certification Mark or Listing Intertek Testing Services NA Inc. - ETL/Warnock Hersey Gary Pfuehler It'] Validation Checklist - Hardcopy Received Standard Year ANSI/DASMA 108 2005 ANSI/DASMA 115 2005 ASTM E1886 2002 ASTM E1996 2002 ASTM E330 2002 Florida Licensed Professional Engineer or Architect FL15279 R1 Eauiv 20120306 - FBC - DASMA 115 eauiv.Ddf http://floridabuilding. orglprlpr_app_dtl. aspx?param=wGEVXQwtDgv3yV VKJZ 1 QRAbbA5BZkl9 l GYlne%2fwb l l7x%2bh7l3 3 oiuA... 9/4/2013 Florida Building Code Online Page 2 of 6 Product Approval Method Method 1 Option A Date Submitted 06/18/2012 Date Validated 06/21/2012 Date Pending FBC Approval Date Approved 07/02/2012 Summary of Products Go to Page Div Page 7 / 7 FL # IlModel, Number or Name IDescription 15279.121 121 W6-18 PAN-21`443: G4S, GS4, Gallery/Artistry/Expressions: Steel Pan (min. 24 ga.) 16'4" GD4S, GR4S, G4SV, GS4V, GD4SV, to 18'2" wide WINDCODE@ W6 Garage Door GR4SV, E4S, ED4S, E4SV, ED4SV, SS4, AR4S, SS4V, AR4SV Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 Rl C CAC Letter with proof of contract and proof of inspection.pdf Approved for use outside HVHZ: Yes Impact Resistant: Yes FL15279 RI C CAC W6 Listino Intertek.pdf Design Pressure: +37 PSF/-39 PSF Quality Assurance Contract Expiration Date Other: Solid doors (no standard glazing) are impact- 05/21/2028 resistant (large missile impact). Installation Instructions FL15279 R1 II 103406-A-Rev06.odf Verified By: Intertek Testing Services NA Inc. - ETL/Warnock Hersey Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.122 122 W6-18 PAN-2F443: G4S, GS4, Gallery/Artistry/Expressions: Steel Pan (min. 24 ga.) 16'4" GD4S, GR4S, G4SV, GS4V, GD4SV, to 18'2" wide WINDCODE@ W6 Garage Door GR4SV, E4S, ED4S, E4SV, ED4SV, SS4, AR4S, SS4V, AR4SV Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 R1 C CAC Letter with proof of contract and proof of inspection.pdf Approved for use outside HVHZ: Yes Impact Resistant: No FL15279 Rl C CAC W6 Listing Intertek.pdf Design Pressure: +37 PSF/-39 PSF Quality Assurance Contract Expiration Date Other: The standard glazing available for this product 05/21/2028 meets the wind load requirements of the building code but Installation Instructions DOES NOT meet the impact resistant requirement for FL15279 Rl II 103406-B-Rev06.pdf windborne debris regions. Verified By: Intertek Testing Services NA Inc. - ETL/Warnock Hersey Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.123 123 W4-09 DSIE-1F171: 4300, Double -skin Insulated EPS (exterior skin 27 ga. min.; 4301, 4310, 4400, 4401, HDG, interior skin 27 ga. min.) Single -Car (up to 9'0" wide) HDGL, HDGF, 66, 66G, 67, 67G, WINDCODE@ W4 Garage Door 68, SP200, SF200, SE200, 6200, 6201, 6203 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 Rl C CAC Letter with proof of contract and Approved for use outside HVHZ: Yes proof of inspection.pdf Impact Resistant: Yes FL15279 Rl C CAC W4 Listing Intertek.odf Design Pressure: +28 PSF/-29 PSF Quality Assurance Contract Expiration Date Other: Solid doors (no glazing) or doors with optional 05/21/2028 impact -resistant glazing are impact -resistant (large missile Installation Instructions impact). FL15279 R1 II 101652-A-Revll.pdf Verified By: Intertek Testing Services NA Inc. - ETL/Warnock Hersey Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.124 124 W4-16 DSIE-1F171: 4300, Double -skin Insulated EPS (exterior skin 27 ga, min.; http://floridabuilding.orglprlpr_app_dtl.aspx?param=wGEVXQwtDgv3yV VKJZ 1 QRAbbA5BZkl91 GYlne%2fwb l l7x%2bh7l33 oiuA... 9/4/2013 Florida Building Code Online Page 3 of 6 4301, 4310, 4400, 4401, HDG, HDGL, HDGF, 66, 66G, 67, 67G, 68, SP200, SF200, SE200, 6200, 6201, 6203 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +25.5 PSF/-25.5 PSF Other: Solid doors (no glazing) or doors with optional impact -resistant glazing are impact -resistant (large missile impact). nterior skin 27 ga. min.) Double -Car (97' to 16'0" wide) NINDCODE@ W4 Garage Door Certification Agency Certificate FL15279 R1 C CAC Letter with proof of contract and FLIS279 R1 C CAC W4 Listing Intertek.pdf Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FL15279 R1 II 101481-A-Rev13.Ddf Verified By: Intertek Testing Services NA Inc. - =TL/Warnock Hersey Created by Independent Third Party: Evaluation Reports Created by Independent Third 15279.125 125 W4-18 DSIE-11`171: 4300, Double -skin Insulated EPS (exterior skin 27 ga, min.; 4301, 4310, 4400, 4401, HDG, interior skin 27 ga. min.) 16'2" to 18'0" wide WINDCODE® HDGL, HDGF, 66, 66G, 67, 67G, W4 Garage Door 68, SP200, SF200, SE200, 6200, 6201, 6203 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 R1 C CAC Letter with proof of contract and Approved for use outside HVHZ: Yes proof of inspection.pdf Impact Resistant: Yes FL15279 R1 C CAC W4 Listing Intertek.pdf Design Pressure: +25 PSF/-25 PSF Quality Assurance Contract Expiration Date Other: Solid doors (no glazing) or doors with optional 05/21/2028 impact -resistant glazing are impact -resistant (large missile Installation Instructions impact). FL15279 R1 II 101247-A-Rev19.Ddf Verified By: Intertek Testing Services NA Inc. - ETL/Warnock Hersey Created by Independent Third Party: Evaluation Reports Created bvIndependentThird Partv: 15279.126 126 W4-09 PAN-21`151: 73, 1500, 75, 190, 84A, 94, 76, 42, 48, 55, 42B, 48B, 55S, 4RST, 6RST, 4RSF, 6RSF, 2RST, GD5S, GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV _imits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +25 PSF/-32 PSF Other: Solid doors (no glazing) or doors with optional mpact-resistant glazing are impact -resistant (large missile mpact). !el Pan (min. 25 ga.) Single -Car (up to 9'0" wide) NDCODE@ W4 Garage Door Certification Agency Certificate FL15279 R1 C CAC Letter with proof of contract and FL15279 R1 C CAC W4 Listing Intertek.pdf Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FL15279 R1 II 300159-A-Rev16.odf Verified By: Intertek Testing Services NA Inc. - ETL/Warnock Hersey Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.127 127 W4-16 PAN-21`153: 73, 1500, JISteel Pan (min. 25 ga.) Double -Car (9'2" to 16'0" wide) 75, 190, 84A, 94, 42, 48, 55, WINDCODE@ W4 Garage Door 4RST, 6RST, 4RSF, 6RSF, GDSS, GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +24 PSF/-24.5 PSF Other: Solid doors (no glazing) or doors with optional impact -resistant glazing are impact -resistant (large missile impact). Certification Agency Certificate FL15279 R1 C CAC Letter with proof of contract and FL15279 R1 C CAC W4 Listing Intertek.pdf Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FL15279 R1 II 101711-A-Rev15.odf Verified By: Intertek Testing Services NA Inc. ETL/Warnock Hersey Created by Independent Third Party: Evaluation Reports http://floridabuilding.orglprlpr_app_dtl.aspx?param=wGEVXQwtDgv3yV VKJZ 1 QRAbbA5BZkl91 GYlne%2fwb l l7x%2bh7l33 oiuA... 9/4/2013 Florida Building Code Online Created bv Independent Third Pa Page 4 of 6 15279.128 128 W4-18 PAN-2F153: 73, 1500, Steel Pan (min. 25 ga.) 16'2" to 18'0" wide WINDCODE@ 75, 190, 84A, 94, 42, 48, 55, 42B, W4 Garage Door 48B, 55S, 4RST, 6RST, 4RSF, 6RSF, GD5S, GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 R1 C CAC Letter with proof of contract and Approved for use outside HVHZ: Yes proof of inspection.pdf Impact Resistant: Yes FL15279 Rl C CAC W4 Listing Intertek.pdf Design Pressure: +25 PSF/-25 PSF Quality Assurance Contract Expiration Date Other: Solid doors (no glazing) or doors with optional 05/21/2028 impact -resistant glazing are impact -resistant (large missile Installation Instructions impact). FL15279 R1 II 101312-A-Revl4.pdf Verified By: Intertek Testing Services NA Inc. - ETL/Warnock Hersey Created by Independent Third Party: Evaluation Reports Created bv Independent Third Party: 15279.129 129 W4-09 DSIE-11`471: GD2SP, Gallery/Artistry/Expressions: Double -skin Insulated EPS GR2SP, GD2LP, GR2LP, AR2SP, (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single- AR2LP, ED2SP, ED2LP Car (up to 9'0" wide) WINDCODE@ W4 Garaqe Door Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +28 PSF/-29 PSF Other: Solid doors (no glazing) are impact -resistant (large missile impact). Certification Agency Certificate FL15279 Rl C CAC Letter with proof of contract and FL15279 R1 C CAC W4 Listing Intertek.pdf Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FL15279 R1 II 103969-A-Rev02.pdf Verified By: Intertek Testing Services NA Inc. - ETL/Warnock Hersey Created by Independent Third Party: Evaluation Reports Created by Independent Third Partv: 15279.130 130 W4-09 PAN-2F441: G4S, GS4, Gallery/Artistry/Expresslons: Steel Pan (min. 24 ga.) G4L, GL4, GD4S, GD4L, GR4S, Single -Car (up to 9'0" wide) WINDCODE@ W4 Garage Door GR4L, G4SV, GS4V, G4LV, GL4V, GD4SV, GD4LV, GR4SV, GR4LV, E4S, E4L, ED4S, ED4L, E4SV, E4LV, ED4SV, ED4LV, SS4, SL4, AR4S, AR4L, SS4V, SL4V, AR4SV, AR4LV Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 R1 C CAC Letter with proof of contract and proof of insgection.pdf Approved for use outside HVHZ: Yes Impact Resistant: Yes FL15279 R1 C CAC W4 Listing Intertek.pdf Design Pressure: +25 PSF/-32 PSF Quality Assurance Contract Expiration Date Other: Solid doors (no glazing) are impact -resistant (large 05/21/2028 missile impact). Installation Instructions FL15279 R1 II 103486-A-RevOS.Ddf Verified By: Intertek Testing Services NA Inc. - ETL/Warnock Hersey Created by Independent Third Party: 11 Evaluation Reports 5279.131 131 W4-16 DSIE-1F471: GD2SP, GR2SP, GD21_P, GR21_P, AR2SP, ��AR21_P, ED2SP, ED2LP Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +25.5 PSF/-25.5 PSF Other: Solid doors (no glazing) are impact -resistant (large missile impact). Created by Independent Third Sallery/Artistry/Expressions: Double -skin Insulated EPS ;exterior skin 27 ga. min.; interior skin 27 ga. min.) double -Car (9'2" up to 16'0" wide) WINDCODE@ W4 3arage Door 'ertification Agency Certificate FL15279 Rl C CAC Letter with proof of contract and FL15279 Rl C CAC W4 Listinq Intertek.pdf 2uality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FL15279 R1 II 104029-A-Rev03.Ddf Verified By: Intertek Testing Services NA Inc. - :TL/Warnock Hersey http://floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZl QRAbbA5BZkl9l GYlne%2fwb ll7x%2bh7l33oiuA... 9/4/2013 Florida Building Code Online Page 5 of 6 Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.132 132 W4-16 PAN-2F443: G4S, GS4, Gallery/Artistry/Expressions: Steel Pan (min. 24 ga.) GD4S, GR4S, G4SV, GS4V, GD4SV, Double -Car (9'2" to 16'0" wide) WINDCODE@ W4 Garage GR4SV, E4S, ED4S, E4SV, ED4SV, Door SS4, AR4S, SS4V, AR4SV Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 R1 C CAC Letter with proof of contract and proof of inspection.pdf Approved for use outside HVHZ: Yes Impact Resistant: Yes FL15279 R1 C CAC W4 Listing Intertek.pdf Design Pressure: +25 PSF/-25 PSF Quality Assurance Contract Expiration Date Other: Solid doors (no glazing) are impact -resistant (large 05/21/2028 missile impact). Installation Instructions FL15279 R1 II 103454-A-Rev06.pdf Verified By: Intertek Testing Services NA Inc. - ETL/Warnock Hersey Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.133 133 W4-16 PAN-2F446: G4L, GL4, Gallery/Artistry/Expressions: Steel Pan (min. 24 ga.) GD4L, GR4L, G41_V, GL4V, GD41_V, Double -Car (9'2" to 16'0" wide) WINDCODE@ W4 Garage GR4LV, E4L, ED4L, E4LV, ED4LV, Door SL4, AR4L, SL4V, AR4LV Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 R1 C CAC Letter with proof of contract and Approved for use outside HVHZ: Yes proof of inspection.pdf Impact Resistant: Yes FL15279 R1 C CAC W4 Listing Intertek.odf Design Pressure: +25 PSF/-25 PSF Quality Assurance Contract Expiration Date Other: Solid doors (no glazing) are impact -resistant (large 05/21/2028 missile impact). Installation Instructions FL15279 R1 II 103454-A-Rev06.Ddf Verified By: Intertek Testing Services NA Inc. - ETL/Warnock Hersey Created by Independent Third Party: Evaluation Reports 1.1 Created by Independent Third Party: 15279.134 134 W4-18 PAN-2F443: G4S, GS4, Gallery/Artistry/Expressions: Steel Pan (min. 24 ga.) 16'2" GD4S, GR4S, G4SV, GS4V, GD4SV, to 18'0" wide WINDCODE@ W4 Garage Door GR4SV, E4S, ED4S, E4SV, ED4SV, SS4, AR4S, SS4V, AR4SV Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 R1 C CAC Letter with proof of contract and proof of inspection.pdf Approved for use outside HVHZ: Yes Impact Resistant: Yes FL15279 R1 C CAC W4 Listing Intertek.pdf Design Pressure: +25 PSF/-25 PSF Quality Assurance Contract Expiration Date Other: Solid doors (no glazing) are impact -resistant (large 05/21/2028 missile impact). Installation Instructions FL15279 R1 II 103498-A-Rev05.pdf Verified By: Intertek Testing Services NA Inc. - ETL/Warnock Hersey Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279,135 135 W4-18 PAN-2F446: G4L, GL4, Gallery/Artistry/Expressions: Steel Pan (min. 24 ga.) 16'2" GD4L, GR4L, G41_V, GL4V, GD41_V, to 18'0" wide WINDCODE@ W4 Garage Door GR4LV, E4L, ED4L, E4LV, ED4LV, SL4, AR4L, SL4V, AR4LV Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 R1 C CAC Letter with proof of contract and proof of inspection.pdf Approved for use outside HVHZ: Yes Impact Resistant: Yes FL15279 R1 C CAC W4 Listing Intertek.pdf Design Pressure: +25 PSF/-25 PSF Quality Assurance Contract Expiration Date Other: Solid doors (no glazing) are impact -resistant (large 05/21/2028 missile impact). Installation Instructions FL15279 R1 II 103498-A-Rev05.Ddf Verified By: Intertek Testing Services NA Inc. - ETL/Warnock Hersey Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: http://floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgv3yV VKJZ 1 QRAbbA5BZkl91 GYlne%2fwb l l7x%2bh7l33oiuA... 9/4/2013 Florida Building Code Online Page 6 of 6 f Go to Page 0 Page 7 / 7 0 0 Back Next Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: f ® c-0� k M F re= efi�C�rF� http://floridabuilding.orglprlpr_app_dtl.aspx?param=wGEVXQwtDgv3yV VKJZ 1 QRAbbA5BZkl9l GYlne%2fwb l l7x%2bh7l33oiuA... 9/4/2013 DIM HE[GM • - MODEL 4F IS FLUSH TARRIATE IOIff' RALffO PANEL EIOOSS DOERS F®ELS a CA a OA DS CLOPAT T.ALLEW GD5S, GRSS GTmV, GRSSv HOLIES •ARTISTRY• Arm ARSSV T� HOUSE, EIDS EDAV I SIOTf PAEL I . y >� vD m DTnJ s SHEET 1 OF 2 REv 9z m no• 1 09 11/30/07 AOOED E1(IEKOED IETOFIIS, COYBBED wv m uKn 2 10 OB/08/08 ADDED 1 42A 488, 555 12TU' m I]'IR' 3 uv m uw 4 11 10/21/05 ADDED I 1 4F 12 8/2OD9 ADDED •CARRIAGE HOUSE' EMBOSS DO 1 13 B/2010 UPDATED MODEL TABLE 14 1/2D12 REVISED MAD SPEED TABLE FOR ASCI OPTIONAL GLAZING MAY BE STANDARD OR IMPACT 15 4/2012 ADDED IMPACT RESISTANT oFnON. RESISTANT GLAZING. SEE SECTION B-B FOR DETAILS. Blast (SEE TABLE FOR OI'0 MAX. STANDARD SIZE IS 42-1/2k16'. IMPACT RRDUEO W/ 7p0-L-E R0P A eo1 1 RESISTANT GLAZING IS 2D1-55/8k14-1/8-. y A WE"TE C��D U-01B5 IN R-1-S-1ECIIO QAT","l N, ONE U�VS ON NEXT SEP:fON. ETTa Ill�llill�lllll�lllll��lllll�lllll�lllll��llll���:1� —,�--,—T� I' ICI ICI ICI I��I�I�I ICI ICI ICI `OF Anon TEARS 1 •CIASSMA 3 RNSED-MUld SUam •GVLdAfE HOUSE SHORT RAID-0ARL IS ALSO APPROVED. E14.5/5' SHEET E41L SCREWS t/4b/4 sFtF LVRID StlRMS O u u FYn IMfFS 1e a EOEPrvmA Wnv w �,�Tc rHee —� A ` OPnONAL OUISEE NETFD =K POSOION . DOOR IMM - le•-O' D�lab15 SEE SHEET TWO FOR IMPACT RESISTANT CONSTRUCTION DETAIL "A" AND STANDARD CONSTRUCT DETAIL "B"; TRACK AND JAMB DETAILS. NCINEER: HARK WESLERFIEID. P.E P.E 148495. 12M 513 1 20 OA WL END ST ES ATOQm m DOOR —EOCEOiC srs1EMMM&} _ Pu ver "w mrl i oi� __ EAx SHIP LAP JOINTS.- 1/ DENSITY POLYSTYRENE FOAM INSULATION 1-5/16 THICK WITH VINYL HAIRCELL BACKER (INSULATED MODELS ONLY) 25 GA MIN. GALV. STEEL SKIN WITH A BAKED —ON PRIMER, AND A BAKED —ON POLYESTER TOP COAT APPLIED TO BOTH SIDES OF STEEL. SKIN. TS W PF315 OR F)REOS THE OESCI U FOR ➢E LLTa1OE IFEO SPFEnS USIED Imw ACCOIOFID m THE nnmA suaDFn DDDE a nE FFRfOtvNN•L ®RdO c40E (MTin pN AsOET-10) FOt 9E PDILwEc coFDOlorRs: 1) EEO® ANY,OOF SIOR, MO Q iLSIMC M ACOOIOVAE Ofll ZOUC 31 At9/nt9M 101 SIZE-SPFOfC fMQ4Q1016 M A OUNEID OE9011 AiS50NL MC pTA O�'Ea O�RO� MO tiz 1>D [AD ffi TATTY ),Gn A.GO 1.0 a,c1 3 NTAH _ HE F'9 US'I a IIS' DF' SECTION A —A (SIDE VIEW) 3- TALL U—BAR 20 GA GALV. STEEL MIN. YEILD STRENGTH: 50 KSI 1THICK -d 3• 1_7/8. rf: T 12 GA GALV. STEEL TOP ROLLER BRACKET. EACH BRACKET ATTACHED W/(4) /14N5/8' SHEET METAL SCREWS. — 14 GA GALV. ROLLER HINGE EACH HINGE FASTENED TO END STILES WITH (4) /144/8' SHEET METAL SCREWS AND (4) 1/4'T3/4' SELF TAPPING \SCREWS. SEE VIEW 'B-. `3' TALL N 20 GA. GALV. STEEL U—BARS IN A 2-1-2-1 PATTERN (I.E. TWO U—BAR" ON BOTTOM SECTION, ONE U—BAR ON NEXT SECTION, ETC.). EACH U—BAR ATTACHED WITH (2) 1/4k3/4- SELF TAPPING SCREWS PER STILE LOCATION. 13 GA GALV. STEEL BOTTOM BRACKET. ATTACHED WITH (2) /144/8- SHEET METAL SCREWS. _ �IO MPC: PAN-2F153 pa y DATE. 1/3/97 DESC 8585 DUKE BLVD. DRAWN By, Building Products MASON, OH 45040 JAC C O m O n (513) 770-4800 OEO= BY, B OOM O<PPOPR11mI An fthb R.. d. MWW LPPROO VAL 15279 DESIGN LOADS: +24.0 PSF & —24.5 PSF TEST LOADS: +36.0 PSF & —37.0 PSF RATTING MAX DOER SIZE. 4 _1 16'0'W X 16'0'H CLASSIC AND CH RP STEEL PAN DOUBLE -CAR, 16'W +24/-24.5 PSF O G MA®EW l Vm 101711 IBC EMBOSS DOORS I DOOR FOCHT - - MODEL 4F IS FLUSH 'CARRIAGE HOUSE' RAISED PANEL OU El6S COO S t®ELS m GA 25 GA DS CLDFAY 'GALJERR GDSS, DIM GDSSV, EASY HO MET 'Mf6TRY' ARS ARAM IDEALTARREAGE HOW EIS EDSSV IMPACT RESISTANT ASSEMBLY DETAILS DRAWING 101711-A SECTION B-B (IMPACT -RESISTANT GLAZING OPTION) �DEDv. tr aPNIONEI DEELPAiIEE IwwnOSE HIGH BOND TAPE SHAP-N NSERE. MO-EDI FRANC AND FXADEJ IONT BCA¢ BELIE SAAANI (BEIWE01 5M SON AND FRAE). ONE 65E'O i a® Ix E POEnTna1E .1 ro . NO, (10) /D . 3/4' PAM IOU NNON E SCROSE wFW.a T16 THE IIPACr-PSISTANE STANDARD ASSEMBLY DETAILS DRAWING 101711-8 SECTION B-8 (NON -IMPACT RESISTANT GLAZING OPTION) FROM FRAE THIN U.V. COMM ON OUTSIDE SURFACE NOTE THAT FRONT FRWE 6 NNUMM THAN IMPACr-RESSANf FRAME. G GAaB MOVED 068E *VYF UTE RETARFR. /GES/N• NYW NEAR SCREW. �ANDARD ASSEMBLY CONSTRUCTION: CON�U�ON: OPf1a1NL 556E DSB OR 1 ACVR C UIER AVAE�nc OPf10N1L ACRIML 6 PIASNOUTE OPTOC OR ACHE CP APPROVED CC! PLASTIC N ACCORDANCE RAIN BC/EBC 2W. THE ENDUE DOOR A40Blr INSTALLED N CDPLMNCE WITH TH6 SECTION NESTS THE WIND LOAD REQUIREMENTS OF RE FLp2M BOOM CODE OR NTE NATONAL BUILDING CODE BUT �• EBI MEET THE OVACr RESISTANT REDIIREIIONT FOR RimBOUE DEBR6 RESIGNS (REF. OAPTER 16 N)C/BC). O0Q FR"SHEET 2 OF 2 3/NI•Es UC SC%16 ON n'^CENfF16.E BIND` 1- 1-1/� =. fA9EA NRGUEBD. IAO Smw MAY BE CGRNIE m (W NOI ISgr 70 PR0110E A Fl191 VOIACING SURFACE NOIRWNL JAMBS DO NOf 1RANSFEIi u110. y�Mn ArrAOR-xr (C-00 �__ In s1MO 19 w. aNrnnc 6'EY SIFFE AMOIOR BWS ON m• CFNIFRS (GD00 P9 NIL CONpEflE)�- IA9Di6 NGIAFD tW1M SLLEVE ANROIS OR 1E4TER TAPCOII MOCK), ON tR DINERS REQUIRED PSI IN. APOORL) OR G' CENTERS (O-GO COIN IT O.D. ILLLSI NDT REGIILFD NIII IAPCOIS NCNd6 WV BE CGADEIIARN (BUr IIOf REGARED W PROEIDE A FU/S1 HORNING SAPAC. HORQONTAL JIYBS 00 110E UmD. ipTQ, REFER To DASMA TDS-101. A OfENSER DEDON PROFESSIONAL RAT ASD BE EMPLODED TO APPROVE ALTERNATE EAs1EIFI6 AND/OR due mKINJUDMEL PRFPARAOII eF AJ� STOP NOADNG BY DOLL NSOWEA GO SLID GEO YFLLDII PIES .RIB m G 1NL MY. "IF3 7DO SERE / m G GILV. STEEL HIFR STILE II I 7//16' ID. (ROUND D PIIDNID i71S1E1� ((TIE PER ROLLDD 11 G GAV. INCE EIOU TO STLES BIN (4HFIGE E))~��� �/E• . ZEAL 3CJFER4 14 G GLV. POLLEN HYE. EAOI HNCE EASRRED To END STI S TINN (4) SHEET MET& SCREWS AND %4�ie7/%C SELF TAPPING SC EWS. (4) 2' 10 BALL SNOUT SUM STEEL ROLLER WON STEEL OR NRLN THE .NIBJNLBWBe1xIL1 sBGEIGn c-G MM- THE DESGN OF THE SUPPORTING SIRWTURAL n8EXIS SMALL BE THE fESPO1BBNIY OF THE PROFESSIONAL M RECORD FOR THE 13 O OR SIRUCIUE AND N ACCORDANCE WON CURRENT BUBDW CODES FOR THE UM LIM ON THE DRAWM ENGINEER: MARK INEMEFfIE D. Clopay Building Products MMAASON UpFj 45040 C011113anY (513) 77D-48W 15279 DESCRIPTION ON SHEET ONE. MM TRACK CONFIGURATION ABOVE THE DOOR OPENING DOES NOT AFFECT THE WIND LOAD RATING OF THIS DOOR. RA T Of HORMDNTA TRACK DOOR iFA (O TALLS AND IAOR xv sm FLAG [RALTEf. LHR TOP BRACKET S1FNm W R700 .NAB WAIN it-SEE'WOOD LAO SCRmmTiU(.KDOUBLE DOUBLEHORQONUL rTAD LOW HEADROOM OPTION . STEEL iiOt IIILGGI/YdI STEELOC iRYJQIi PR SOIL 3E NEEDED. DAVAAABE DOORS OVER M TAIL O' OAK 57FEL 1PACK 1w. 1HICIQE.4 LW' uN. ikkMiE OTIE WN I AO WP MH ICK S NOT W MIDI) 30' Olt I MM FOR DOORS OVER 'L• Ir-O• HwK V" $ aCOIFIGIRMOSOUL NOT SOUNOT b EXCEED uAOAtY S•AOO PROV CONSULT FICMW FOR MORE OCTAL F ROD. }Iz I DESIGN LOADS: +24.0 PSF & -24.5 PSF TEST LOADS: +36.0 PSF & -37.0 PSF �hCTURDli PRODUCT MPC: PAN-2F753 AD�LD4n RMiTG NAK >mL slzE DATE W 4 16'0'W x 16'0'H 1/3/97 N=WTZN CLASSIC AND CH RP STEEL PAN DRAWN BY. JAC DOUBLE -CAR, 16'W +24/-24.5 PSF C EOED BY, DRAVD6 -N'm I VM MWW B 101711 BC