Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SUBMITTED PAPERS
Fee Due, = ,1 Permit # I r�U(a Planning & Development Services Building & Code Regulations Division 2300 Virginia Ave. Fort Pierce, FL 34982 (772)462-1553 %9C "9t < eyNF® oci; COO, SPECIALTY PERMIT APPLICATION ❑ Electrical C Plumbing ❑ HvAC ❑ Fence ❑ Shed ❑ Demolition ❑ Gas ❑ Siding Seepage 2 for instructions and additional paperwork required for specialty permits 1. Location/Site Address: 9?:0-A FOV_T�tF-q 'c �9Vp, �i i7i �, IPL ��&I 2. Parcel ID Number: 130I - (00�S' C51 A?;c CEO m I Office Use Only Section Township Range Map Page Zoning Land Use Initials 0 3. Complete Description of Project or Work: WSM(ALL. � Wpm .L�014-TE_P?, 14F.R' W-- 4. Owners Information 5. Contractors Information Name: k7)ejr a- _ VA O Address: S20?) FOPT A E1ZCr_- VIiV 0 City: 'V4-. P1e.1r(, State: VL '1 Zip: r?)at) 1 Phone: 6. Value of Construction: $�J•C)C) FL Reg/Cert #: County Cert#: Business Name: 71 o1Z10 fa A Sus Phone: 1 1^�d��l®Fax: 3GP l OWNERS AFFIDAvrr: I certify that all of the information contained in this application is correct and that all work will be done in compliance with all applicable. laws regulating construction and zoning. PRINT OWNER OR CONTRACTOR NAME p a� (� SIGNATURE OF OWNER OR CONTRACTOR STATE OF FLORIDA, COUNTY OF err_�•V l-9—® ACKN ED ED BEFORE ME THIS J,/ DAY OF ` `� 20 1 a , BY WH IS PER NALLY KNOWN TO ME " OR WHO HAS PRODUCED HEATHER M, WITH AS EN C NOTARY PUBLIC -S TATE OF FLORIDA 1 Stamm# EE122843 SI OF OTAR TYPE OR PRINT NAME OF NOTARY Expires 8/17/2015 NUMBER TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. EXEMPT: A/C -HEAT REPLACEMENT WITH CONTRACT UNDER $7500.00 Revised 04/26/2010 r , NOTICE OF COMMENCEMENT Permit No. State of Florida County of St. Lucie Tax Folio No. &I 10 The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. General description of improvementrAsithI I gAe�x col A. dhw suskm Owner Name Addres: Interesi Name and addr_es; gf ffeee simple titleholder (if different from Owner listed above): Contractors Name: Contractor AddresN Surety (if applicable, a co y of the Bayment bond is attached): Amount of bond: $ Name and address: Phone number: Lender Name: NCWn:::! Phone Number: Lenders address: Persons within the State of Florida designated by owner upon whom notices or other documents may be served as provided by Section 713.13(1q)7F(ali�a Statutes: Name: V Nam, Phone Number: Address: In addition to himself or herself, Owner designates "0 VA G of Uenors Notice as provided in Section 713.13(1) (b), Florida Statutes. Phone number of person or entity designated by owner: to receive a copy of the Expiration date of notice of commencement: (the expiration date may not be before the completion of construction and final payment to the contractor, but will be 1 year from the date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under p of perjury, I declare that I h e read the foregoing notice of commencement and that the facts stated therein are true to the best of my kn I ge and belief. ignature of Owner or Lessee, or Owners or Lessee's Authorized Officer/Director/Partner/Manager If (Signatory's The fo goin strument was acknowledged before me this day o� , 2t CF`�� "' for ame on Typ of authority (e.g. officer, trustee) Party on behalf of instrument was executed Personally known_ or produced Identification ( ' hat re of o ary P blic - State of Florida) Tint, ype, or Stamp Commissioned Name of Notary Public) Type of Identification produced YA HEATHER M. SMITH NOTARY PUBLIC STATE OF FLORIDA We Comm# EE122843 h'G`li 191$ -irps 8/17/2015 X0-ncn Q ;o F 0 CU C) rn — p) U oaks ro c�0S°rz �w�nm oPmO-i oM(yrQ C2 2 n np.�{r N m 91 �f O - CO O C1 ii .n n y K m 3 (7 � n c c� 0 C 6/1/12 (.iol,c W Ilur:nl IZern1-d1 1 nl 1 P 1-4) 11 crh I d('11 I i I i l:ilil l II Site Address: 8303 Fort Pierce Blvd Sec/Town/Range: 02 :34S :39E Map ID: 13/02N Zoning: RS-4 O„lit 1,11ill anti �leiiiu 1��1 • \ operty Appraiser - St.Lucie County, FL PROPERTY RECORD CARD !'le \(.\I - 'pr,.11"nlm Owner: George W Horan Joyce C Horan Address: 8303 Fort Pierce Blvd Fort Pierce FL 34951-3414 ."A;, 101,111latinu Date Price Code Deed 10/2/2002 107000 00 WD 8/2/1993 100 01 WD 4/1/1983 14300 01 CV 1/1/1981 12500 00 CV 1/1/1973 4800 00 CV ParceliD: 1301-608-0123-000-1 Account #: 2110 Land Use: SF Res City/Cnty: St Lucie County 1: 1-a+pli lri, au1i1 Ilun11 I'lin, 7� Ih..lillliuu LAKEWOOD PARK -UNIT 8- BLK 92 LOT 18 (MAP 13/02N) (OR 1604-2115) :\ (•S,III.III'_I)lI I.111.11 Book/Page 2011 Final: 84200 1604 / 2115 Assessed: 65671 0856 / 2889 Ag.Crodit: 0 0398 / 0732 Exempt: 40671 0347 / 0455 Taxable: 25000 0210 / 2311 Taxes: 632.1 M 11.mm, I\I r)I(U I If)", I mA Land :Ill() Iiuildm„ Land Value: 13500 Acres: 0.27 Building Value: 70700 Finished Area: 1520 SgFt t CIt9'I+)!' Iivtil rt•� View: - RootCover. SD - Dim Shingle RooStruct: HP - Hip ExtType: HC - HC YearBlt: 1983 Frame: - Grade: C - C ESYrBIt: 1983 PrimeWall: FS - Frm Stucco StoryHght: 0010 - 1 Story No.Units: 1 SecWall: _ fnulio:' l�raunr• BedRooms: 3 Electric: MX - MAY1MUM PrmintWall: DW - Drywall FulfBath: 2 HeatType: FHA - FredHotAir AvgHt/FI: 1/2Bath: 0 HeatFuel: ELEC- Electric Prm.Flors: CU- Carpet %A/C: 100 %Heated: 100 %Sprinkled: 0 tipCCi:11 Fea(llre, alld i:1i'd Itoll, I atl(I f IIIUI'11111110❑ Type Y/S Qty. Units Qual. Cond. YrBlt. No. Land Use Type Measure Depth DWC - Driv-Contest Y 1 720 AV AV 1983 1 0100SF Res LF1 Front Ft 90 130 ENC2 - POOL ENC AVG Y 1 1360 AV AV 2003 PA01 - POOLDKAVG Y 1 910 AV AV 2003 S W AV - RES POOL AVG Y 1 450 AV AV 2003 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED 7 T Permit71 - No. Tax State of Florida County of St. Lucie ..... ..... The undersigned hereby gives notice that improvement will be made to certain, real pr6perty, and r ancewith-d withr Chapter a;s, the following information is provided in this Notice of Commencement L ID Le e I n of P de6et, '�. gav, bled; ----------- ---------------------- _Tdrekf- General. description of improvement _r -wier tionolationrifltleLWeeo ctecfbr:theimpr avement*—--M0 ;oU' Mn —y) Name _-Addres cCf)) 0 C, M ... �Interesp�ope W 7 G) rty! Z- ow—0Nzffieandaddres''ffeesimpI—titlehqlder(ifdiffeentfrom-Ownerliked 656W)_Ws?i, a V 0 > Q? o q Contractor's Name: M;� Z Contractor Addres r- hone-Numbe M Surety (if applicable,fJhT ayment bond is attached): Amount -of bond:-$:-,,, 9 0 Name and address.0, -n C, Phone-numbeor. 0 )> --I M Lender Name: Phon R 0 Lender's address- z 58 C Persons . ns; within the State of Florida. designp-te-d by Owner upon whom- it.9tices or-othei -documents may be - served as provided . ed by Section 0 713.13(l 7, 1 Statutes: 0 Phone Number: 4 In addition to himself or herself, owner designates _ NO tA S': Llenor's Notice as provided in Section 713.13(l) (b), Florida Statutes. of to receive a copy of the ro Phone number of person of entity designated by owner: Expiration date of notice of commencement: (the expiration date may not be beforethe completion of constructl - a . rLandfinal payment I to the contractor, but will be 1 year from the date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER 'THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION.713.13' FLORIDA STATUTES, . AND CAN RESULT IN YOUR, PAYING TWICE FOR IMPROVEMENTS To YOUR PROPERTY. A Nana OF COMMENCEMENT musr BE REGARDED A_N_ 6 POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Un&derp perjury, I declare that I h e read the foregoing notice of commencement and . that the facts stated therein are true to the best of of my kn I ge and belief. X-1 i ig 0 a u Zf w r or gnature of Owner Owner's or Lessee's Authorized Officer/Director/Partner/Manager (Signatory's TZ/Office) The fo g6in strument was acknowledged before me this day ll_�.' 2L2)1 for ame on Typ of authority behalf instrument (e.g. officer, trustee), Party behalf o. was executed hat re o Personally known_ or produced Identification Pei;�n 6 ary Pdblic -State of Florida) U) rint, ype, or Stamp Commissioned Name of Notary Public) Type of Identification produced y y HEATHER M- SMITH" _ram n NOTARY PUBLIC STATE OF FLORIDA Comm# EE122843 WOE is 17" irAs 8/17/2015 Planning & Development Services Building & Code Regulation Division Permitting Department 2300 Virginia Avenue Fort Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 PROPERTY INFORMATION Address: 8303 FORT PIERCE BLVD City / State / Zip: FORT PIERCE Parcel # : 1301-608-0123-000/1 Zoning: RS-4 APPLICATION INFORMATION Permit Number: 1206-0048 Activity Type: Permit Type: Solar thermal hot water heaters 4 Review Comments FL 34951 Jurisdiction: St. Lucie County Lot # : 18 Block: 92 CONTRACTOR INFORMATION Contractor Name: WEST, ARTHUR Business Name: FLORIDA SOLAR EAST Business Addr: 1743 HUNTING LANE #S-101 City / State / Zir ROCKLEDGE, FL 3295! REVIEWS AND COMMENTS Review Type Status Front Counter Review Complete Page 1 Owner(s): George W Horan Joyce C Horan Application Type: Over the Counter Permit Other Activity: Stories: 1 Automatic Sprinkler System? Reviewed By Dawn Milbne Fax Number 321-631-9332 To Be Review by Plans Exan Incomplete Greg Smyth 06/05/2012 1 Comment cannot use copy of engineering for permitting. Date Started Date Complete Date Released 06/05/2012 06/05/2012 06/05/2012 "s TRANSMISSION VERIFICATION REPORT TIME : 04/19/2012 04:51 NAME : FAX : 4622885 TEL SER.# BROM5J411427 DATE,TIME 04/19 04:50 .FAX NO./NAME 913216319332 DURATION 00:00:29 PAGE(S) 02 RESULT OK MODE STANDARD ECM Planning & Development Services Building & Cade Regulation Division Review Comments Permitting DepaAment 2300 Virginia Avenue Fort Pierce, FL W82 Phone: (772) 462.1662 Fax: (772) 462.1678 Address: 8303 FORT PIERCE BLVD City! State 1 Zlp: FORT PIERCE FL 34951 Parcel # : 1301.608-0123-00011 Jurisdiction: St. Lucie County Zoning: RS-4 Lot#: 18 Block: 92 APPLICATION INFORMATION Permit Number: 1206-0048 Activity Type: Permit Type: Solar thermal hot water heaters CONTRACTOR INFORMATION Contractor Name: WEST, ARTHUR Business Name: FLORIDA SOLAR EAST BusinessAddr: 1743 HUNTING LANE ##S-101 City 1 State ! 23F ROCKLEDGE, FL 3295; Page 1 Owner(s): George W Horan Joyce C Horan Application Type: Over the Counter Permit Other Activity: Stories: 1 Automatic Sprinkler System? REWEWS AND COMMENTS Review yye Status Reviewed,Bv Front Counter Review Complete dawn Milane Fax Number 321.631-9332 Date Started Data Complete Data Released 06/05/2012 0610512012 To Be Review by Plans Fxan Incomplete Greg Smyth 06/0512012 F.S.E. (886) 44-SOLAR 01 '."A fa 4541.8 St. Augustine Road 1743 Huntington Ln., Ste.101 545 Mercantile PI., Ste. #115 2600 Hammondville Rd #32 fast Jacksonville, FL 32207 Rockledge, FL 32955 Port St. Lucie, FL 34986 Pompano Beach, FL 33060 (904) 240-1574 (321) 631.8990 (772) 344-0237 (954) 968.0114 (904) 647-5431 Fax (800) 922.5299 (886) 447.6527 (954) 968-0235 CWCO27561 CPC032536 JOB LOCATION: INVOICE ADDRESS: NAME6 e�o2G� 1oRd-NAME �-t HOME PHONE 7.71-4 C- A, Seo ADDR S S O �T P l ell cc a wb ADDRESS 'WORK PHONE CITY ::T 7t FIl`� �c.. 3 Oat CITY ZIP ( JOB NO. LEGAL PO. NO. SOLAR PANEL (TYPE) gyp'=�'© ��n'T- -PLUMBING A S til€��E� LEAD SOURCE NUMBER OF PANELS. S 1-# PANEL SIZE 4 X % TO 4 X l Z., OCCUPATION MR MRS COMPANY AUTO CONTROL i N L:- *--" W�w POOL COVER _ r - L- 7;- 1 f . TANK SIZE # OF USERS OPUCINS Q urricane Package ever Lube Valves [� ignature Plumbing r) 2" Check Valves ['Self -draining System [� bel & Paint Pipes Additional Comments PERFORMANCE GUARANTEE FLORIDA SOLAR has designed your pool heating system to add 12--14 • degrees (F) to the temperature of your pool to keep your pool temperature at %6 degrees (F) or higher from approx. L'fE FERa approx. 0—' — . Your performance guarantee assumes the use of a pool cover. Your performance guarantee is based on the last 20 years of weather and your pool temperature will go up.or down as the average weather Increases or decreases. 90 Day Guarantee. If within 90 days from the original installation date of your system you are not completely satisfied with the above stated performance, we will modify the system to meet your satisfaction at no additional cost to you. The buyer has the right to cancel the transaction at any time prior to midnight of the third business I day after the date of this transaction. A�/ 3uyer i M��MM _ Mj1 _ e Date Date 3. 2o— 12 Date POOLAREA SCREENED OPEN ' BASE DN 8qcl - SYSTEM Pip OPTIONS TOTAL INVESTMENT I S ( g . s'ri C� f31$ s &q-5 DEPOSIT 5-0 BALANCE DUE ON COMPLETION A O l s, MONTHLY INVESTMENT UPON APPROVAL DESIRED INSTALLATION DATE Email -floridasolareast@bellsouth.net. Web - floridasolareastnet ►SALES REP DameH 0rc,.0 address � :it1r � hone (H)7R-116= MW4 Type ( )FAFCO Nov Tank: YES ( ) Size . f� Substrates ( ) Yes v of Users Speclaf Schedules? r (gXY0) Eagle Sun -= =No�() ) No tINS TALL /NFORMA TIOAtS TUC TURE /AfFo,#/OV Area available For Install (closet sPxe) Root Type N�) (H) Roof color ( ) Comfort System ( ) Timer 'Exterior ll Type fisc■ into Exterior !Mall Color Height (D Single ( ) Two pitch Opien Beam Ceiling-• ( ),Ness ADDITIOAfA FAppm.Pipe Run Ft. Spltds TreTION nching Length. FL Banks I�JD/CA7FSOUTH • • • , , F-I LE C.- 0 P SALES REP . • LEAD SOURCE :LECT PA iffiff.Yes ( ), ° 46' - 52' VARIES wl NUMBER OF COLLECTORS DACRON BODY STRAP AND CONNECTION TOP AND BOTTOM OF ALL PANELS FASTENED WITH ...IX THRUBOLT TO ALUMN, RACK BELOW— `—TYP. CONN. TO (2) #12 SMS 11 8'. 10', 12' TALL x 4' ROOF (FLUSH) FA CONN. WIDE SOLAR PANELS SEE DETAIL (A101) 1'x2'x118• ALUMN. DACRON BODY STRAP PULLED 'U' CHANNEL TIGHT (SEE STRAPPING SPECS 4/A-1 FOR LOCATIONS) —1'x7018' ALUMN. ANGLES DOWNWARD (SEE DETAIL 2iA-2) —TYP. CONN. TO ROOF BELOW (SEE DETAIL 31A-I) NUMBER OF BAYS VARIES AS NEEDED 1 �o SOLAR PANEL ROOF MOUNTING 1"x2"x1/8" ALUMN. "U' CHANNEL 2'x1l8' ALUMN ANGLE CLIP APPLY ADHESIVE IN ILOT HOLE AND OVER 7FAS'TNER 1/2 SS THRUBOLT� TO ATERPROOF CENTERED TYP. ELEVATED SHINGLE/TILE HOUSE ROOF & COVERING (MAY VARY ASPHAULT, TILE, METAL, (OTHER) — BRACKET CAP MOUNTING----,,,, BRACKET BASE #12 OR BETTER STAINLESS STEEL SCREW TO FULLY PENETRATE ROOF SHEATHING AND FASTENED INTO ROOF TRUSS TOP CHORD AT ALL HEADER STRAP TIEDOWNS BRACKET CAP MOUNTING BRACKET BASE \ HOUSE ROOF & COVERING (MAY VARY ASPHAULT, TILE, OTHER) 1/8" PILOT HOLE & —� SICAFLEX SEALANT LBODY STRAP OCATED WITHIN 12" OFFBOTTOM HEADER 1/8' PILOT HOLE & SICAFLEX SEALANT r #12 OR BETTER STAINLESS STEEL SCREW FULLY PENETRATE ROOF SHEATHING 0 SCALE: N.T.S. 5 t2,M:O" ` N T I N G DETAIL JJR-AP QUANTITY AND SPACING ZONE 1 & 2,- UNIT LEN.GF STRAP QUANTITY STRAP SPACING 3 DACRON BODY STRAPS STRAPS TO BE EVENLY TMARCE—D. END STRAPS TO BE WITHIN 12" FROM ND OF PANEL, 10'-0' 3 DACRON BODY STRAPS y 12'-0• 4 DACRON BODY STRAPS H MOUNT) TIE DOWN CL'QMBASE OR OTHER MOUNTIN(NARDWARE (TIE DOWN CLEAT CAN BE CC;CATED IN VALLEY AREA BETWEEN-TIL•E1— INSTALLATION INSTRUCTIONS 1. MARK HOLES AS SHOWN ON PLANS. 2. DRILL 1/8" PILOT HOLES. 3. APPLY SICAFLEX ADHESIVE IN AND ABOVE HOLE. 4. SECURE BASE W/ #12 OR BETTER SS SCREW. 5. INSTALL BODY STRAP AND SECURE CAP. 6. SEE 4 / A-1 FOR SPECIFICATIONS ON NUMBER OF BODY STRAPS PER SOLAR PANEL. REFER TO MANUFACTURER INSTALLATION INFORMATION FOR MORE DETAILED INSTALLATION DESCRIPTION. HEADER STRAF TOP HEADER — BODY STRAP LOCATED WITHIN 12' OF TOP HEADER STRAPS FILE COPY ST LUCIE COUNTY 13UILDING DIVISIO REVIIEWED [FOR C®MnLAwcE : N.T iUS'f��q�rMIT OB OR I ECi(ON WILL BE MADE a �1� ROOF SHEATHING 3/8'x3"MIN. SS LAG SCREW (2' o �1 h11N. PEN. TO WOOD TRUSS 4 o STRAPPING S P E C ' S SCALE: N.T.S.rVI TRUSSSS OR BLOCKING \ ROOF SHEATHING 2'MIN. WOOD �' r 12 OR BETTER SS SCREW TO FULLY THESE PLANS ARE NOT VALID FOR PERMITTING WITHOUT THE RAISED SEAL & SIGNATURE ENETRATE ROOF SHEATHING GNATURE OF CONTRACTOR IS RESPONSIBLE FOR ANY SCALE: N.T.S. AND ALL DAMAGES 70 TILES o, ENGINEER/ARCHITECT OF RECORD. SCALE: N.T.S. 3 W ELEVATED SOLAR PAN ONNECTION DETAIL ,'JRITTENDIMENSIONS SHALL HAVE 6 MOUNTING HARDWARE OVER TILE PRECEDENCE OVER SCALE DIMENSIONS, o E ROOF Contractors shall verify and be responsible for dimensions and conditions of the job and the owner must be notified in writing of any changes in the dimensions• conditions, and specifications appearing on these plans. U �1 R C t—i t N O L a .rs I Drawn By: J M.L. Checked By: D.B. Date: Scale: As Noted Job Number. CO-00005 drawing no. A-01 i0I. AR OE TAILS 1 �"7 . Ia DACRON BODY STRAPS & CONNECTIONS. TOP, MID, & BOTTOM OF ALL PANELS FASTENED PER; . DETAILS_41P-01 & 51P-M; (SEE CHART FOR SIZES &.STRAP PLACEMENTI— BREAKER Id. 19 TALL X * tlb 90LARPANRA STRAP ) PTO POOL VALVE mom;014d I ME 1plimp Va d Ap FLORIDA SOLAR ENERGY CENTER CERTIFICATION SPEC'S. COLLECTOR GLAZING ABSORBER GROSS THERMAL PERFORMANCE AREA INTERMEDIATE TEMPERATURE RATING REVOLUTION UV STABILIZED FAFCO INC. 908R 98003C 0 NONE PLASTIC NONE 31.76 18300 576 POLYMER REVOLUTION UV STABILIZED FAFCO INC. 91OR 98004C 0 NONE PLASTIC NONE 39.70 22900 576 POLYMER REVOLUTION UV STABILIZED FAFCOINC. 912R 96023 0 NONE PLASTIC NONE 47.45 27300 576 POLYMER SUN SAVER UV STABILIZED FAFCO INC. 918 95001C 0 NONE PLASTIC NONE 31.60 14300 452 POLYMER SUN SAVER UV STABILIZED FAFCO INC. 920 95002C 0 NONE PLASTIC NONE 39.50 17900 452 POLYMER SUN SAVER UV STABILIZED FAFCOINC. 922 95006C 0 NONE PLASTIC I NONE 147.791 21600 452 POLYMER 7 o SOLAR ROOF MOUNTING PLAN (FLUSH AND SCI IIP. 4'-0' MIN. TYP. SYSTEM HAS BEEN DESIGNED WITH THE FOLLOWING LIMITATIONS: A. UP TO 14OMPH WINDS (3 SECOND GUSTS). B. ROOF HEIGHT NOT TO EXCEED 30' ABOVE GRADE (IF ANY OF THE ABOVE LIMITATIONS ARE EXCEEDED SPECIAL ENGINEERING WILL BE REQUIRED). DESIGN NOTES: STRAPS SHALL BE DACRON BODY STRAPS AND HAVE A MINIMUM DESIGN TENSILE STRENGTH OF 1,600LBS. SCREWS SHALL BE #12 OR BETTER STAINLESS STEEL AND SHALL FULLY PENETRATE 1/2' MIN. COX. PLYWOOD SHEATHING AND BE HELD IN PLACE WITH SICAFLEX 1a CONSTRUCTION SEALANT APPLIED TO A 118" PILOT HOLE PRIOR TO AND AFTER PLACEMENT OF THE FASTNER AS SHOW HEREIN. EACH PANEL SHALL HAVE MINIMUN OF (5) MOUNTING POINTS WITH AN ADDITIONAL (5) ON ONE END OF THE ARRAY. A FOUR PANEL SYSTEN WILL HAVE (25) MOUNTING POINTS. DETAIL VALID FOR HVHZ ZONES UP TO AND INCLUDING 140 MPH. THIS DETAIL NOT VALID IN DADE COUNTY. DESIGN REQUIREMENTS NOTE: THIS STRUCTURE HAS BEEN DESIGNED TO MEET OR EXCEED REQUIREMENTS OF THE FLORIDA BUILDING CODE 2010 1. WIND EXPOSURE -CATEGORY (B OR C) 2. ULTIMATE DESIGN WIND SPEED -170 MPH. NOMINAL DESIGN WIND SPEED • 132 MPH. 3. WIND IMPORTANCE FACTOR -1.0 4. INTERNAL PRESSURE' COEFFICIENT-.18 S. MAXIMUM PRESSURE FOR COMPONENTS AND CLADDING, 42.0 p.s.fJ-54.9 p.s f. UNLESS NOTED OTHERWISE. SCALE: N.T.S. 8'4',19-',12'-W AS NEEDED 'x2"x1/8' "U' CHANNEL TO BELOW w/ (2) #12x2' SMS 'U' CHANNEL 1"x2'xl/8"U' CHANNEL wl 1/2' THRBOLT @ EA. END 252'xl/8"U' CLIP (SEE DETAIL 31A-1) EXISTING SECTION (ELEVATED) SCALE: N.T.S. GENERAL NOTES: 6-ENIGINEERiN ..VALID FOR SOLAR POOL HEATING AND DOMESTIC WAMUJEATIN y 0NS. 2. ENGINEERING VALID FOR ALL PANEL ORIENTATIONS INCLUDING VERTICAL (SHOWN) AND HORIZONTAL. 3. CALCULATIONS VERIFIED FOR THE UPLIFT ONLY PER CODE. INSTALLERS SHALL USE CAUTION WHEN INSTALLING THE PANELS TO MINIMIZE AND DISTRIBUTE LOADING ACROSS THE ROOF SURFACE. NO WARRANTY, EXPRESSED OR IMPLIED IS OFFERED FOR THEINTEGRITY OF THE EXISTING STRUCTURE. • ' 4.112' MINIMUM EXTERIOR GRADE COX PLYWOOD SHALL EXIST AS A CONNECTION SUBSTRATE. 5. NO CERTIFICATION IS OFFERED FOR PLUMBING OR ELECTRICAL WORK THIS IS A STRUCTURAL CERTIFICATION ONLY FOR ANCHORAGE TO THE EXISTING ROOF STRUCTURE. 6. DIMENSIONS ARE SHOWN TO ISSUSTRATE DESIGN FORCES AND OTHER DESIGN CRITERIA. THEY MAT VARY SLIGHTLY. CONTRACTOR IS TO VERIFY ALL FIELD DIMENSIONS PRIOR TO INSTALLATION. 7. ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR, et. al. INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COST DAMMAGES INCLUDING LEGAL FEES & APPELATE FEES RESULTING FROM MATERIAL FABRICATION SYSTEM ERECTION, & CONSTRUCTION PRACTICES BEYOND THAT WHICH IS CALLED FOR BY LOCAL, STATE, & FEDERAL CODES, & FROM DEVIATIONS OF THIS PLAN. r 8. SYSTEM HAS BEEN DESIGNED WITH THE FOLLOWING LIMITATIONS: A. UP TO 14OMPH WINDS (3 SECOND GUST). `�f B. ROOF HEIGHT NOT TO EXCEED 30' ABOVE GRADE. l�( (IF ANY OF THE ABOVE LIMITATIONS ARE EXCEEDED SPECIAL ENGINEERING WILL REQUIRED. 9 Drawn By: J.M.L. Checked By. D.B. Data. Scale: As Noted Job Number. 00-0000s drawing no. A-02 SOLAR DETAILS THE GUARDIAN SOLAR WATER HEATING SYSTEM (OPTIONAL) SYSTEM DIAGRAMS OPTIONAL 2nd PANELASNEFOrO 1s ; ROOF PENETRATION AND FLASMINO DETAIL 7IA43 , twNTINt1 BRACKETS A72 t r fr LOCATIONS TOP A BOTTOM FASTENED PER DETAIL. G, SOLAR RETURNl ?SOLAR 120 VAC r' I 1 I 1 1 1 RETURN SOLAR FROM ® SUPPLY' PVPANEL I • I TO PV 1 ,, THERMOSTAT FANB- ` 6 HEATING. I ELEMENT ; 12 7 IB I 1 s 1 ,IT 13 S I ,IT 1 \� --- COLD A 3``�~��� 1 I TOP d OF TANK IPVLOC) UMSING DETAILS LECTOR OUILET, ROOF ETRATiON AND FLASHING DETAIL 7IA43 \ Or E)IT LAP �ErO J`� rtILr NO. DESCRIPTION 1 SOLAR STORAGFJ WATER HEATER S 'CIFFERENTIALTEMP CONTROL �1E 'TEMPERATURE SFNSOIt(S) IIRELECQUCAL'MRS S CATE'SHUrOFF•YALVE s FREEZEPROTE:TION VALVE 7 CIRCULATION PUMP - 1610 ISOLATION BALL VA011M q14 SOILERDRAINM 10. PRESSLRERELEFVALVF 12 ANT4THERr OSPHONVALVE 15 SOLAR COLLECTORS) 1s "PVMCOLLE 17 ARVENT 9 "PV HRIrR CONTROL ' ACONLYITEMs •• PV-DC CNLYITE.M3 8 �W SOLAR WATER HEATING SYSTEM (OPT.) GALVANIZED METAL FLASHING SURROUNDING ROOF PENETRATION ATTACHED TO EXISTNG ROOF STRUCTURE WITH SICAFLEX SEALANT PER MANUFACTURERS SPECIFICATIONS TO PREVENT LEAKING GALVANIZED METAL FLASHING (TYP) SCALE: N.T.S. OPT. ATTIC FAN DETAIL OR TWO PREMANUFACTURED OPENINGS IN FLASHING `e - -ffic-a ion: 0 Drawn By: J.M L Checked By: D.B. Dale: Scale. As Noted ` Job Number. V 00.00005 \I drawing no. t'I A-03 .. I 30LAR DETAILS THE GUARDIAN W/ SUNPAC SOLAR PANEL COLLECTOR qr SOLAR WATER HEATING SYSTEM SOLAR WATER HEATING FASTENED TO MOUNTING PANEL MOUNTING BRACKET BRACKET BY MFG. - -- MIN. 2 LOCATIONS ON TOP & - - - - - - - - :3 BOTTOM (OPT. SIDES) _-----ROOF SHINGLE/TILE ROOF SHEATHING-,""." '-APPLY ADHESIVE IN PILOT HOLE AND OVER FASTNER TO WATERPROOF 2"x4"MIN. WOOD TRUSS OR BLOCKING 3/8" x 4" LAG SCREW OPTIO PANEL PANEL I 0 OP y fj SEE ROOF PENETRATION & FLASHING DETAIL 71A-03 MOUNTING BRACKETS @ 2 - LOCATIONS TOP & BOTTOM FASTENED PER DETAIL 91A-04. R TO WATER FROM INCOMING SOLAR SOLAR COLD WATER HOT WATE9' TO (OPT) PERING VALVE 0 L-i WATER SUNPAC HEATER 8 Q SGOrAR WATER HEATING SYSTEM w/ SUNPAC (OPT.) SCALE: N.T.S. UNIVERSAL HINGE, MOUNT PANELS FASTENED @ MIN. 2 LOCATIONS @ TOP & BOTTOM SHINGLES 2"x2"xl/4" STEEL ANGLE EXTENDING A MIN. OF 2 TRUSSES BEYOND END OF PANEL. ATTACHED TO UNDERSIDE OF TRUSS TOP CHORD w/ 3/8"x4" LAG SCREW 3/8" THREADED ROD BOLTED TO STEEL ANGLE w/ 1" WASHERS TRIANGLE BRACKET 318"x1-3/4" BOLT SHEATHING J C: 4 Drawn By: IM.L. Checked By: D.B. Date: Scale: As Noted Job Number. 00-0000-q Jrawiro no. A-04 A AR OETAILS COW watoisu Pply. Hot w*W-fa homal. Tbsolarcelladiars Arr Coldwater 'Z r fa val" 7CNeekYalva AL A Temperswro sypas, 7011.71 Control Valve ,I. M V111w. 53 pgr con"... MM F. Water heater gxpunsbs reservoir - Aft ftlar collectors SCALE: N.T.S. Air VaMseetim reservoir Ho! water 16 III!=-& V; c6ld Water sup*• ;7 tW. L Temwevature to soar. woutm ConhoLvklvo YiIr FIN valve 7 Check Val" ji self m Cleaning,' ordlavalSolarcollectors Ffter Prr vat" I- s. M Temperature ContrdVa.1va ifiaterheaft SCALE: N.T.S. F-FFAFCO- 50-0 SERIES -DUAL -TANK HOVWATER - -HEATER -SYSTEM F_AFCO 500 SERIES SINGLE TANK HOT WATER HEATER SYSTEM IM Er 2 Drawn By: J.M.L. Checked By: 0. B. Date: Scale: As Noted Job Number-, 00-0000S drawing no. A-05 SOLAR nETAILS