Loading...
HomeMy WebLinkAboutSUBMITTED PAPERS2 ffn Planning & Development Services Building & Code Regulations Division 2300 Virginia Ave. tS�q Fort Pierce, FL 34982 �Vlvl�b (772)462-1553 &t 44 SPECIALTY PERMIT APPLICATION cie County ❑ Electrical ❑ Plumbing HVAC ❑ Fence ❑ Shed ❑ Demolition as ❑ Siding Seepage 2 for instructions and additional paperwork required for specialty permits 1. Location/Site Addr( 2. Parcel ID Number: Township Range Map Page Zoning Land Use Initials Office Use Section Only - /IWL-?012 u 3. 4. Name: •s Information v ractors Information 21yi Y- & FL Reg/Cert #: Address: 10I Y 24 P(— City: PSLY V State: 22 D �j 7n 2 V — Zip: Phone: 4(pQ 1-111 6. Value of Construction: $ 3� County Cert#: CACD)UT-(�O-�9 ZLQ�I � �n-L�t: Business Name: 'SC,YU 1 Q—A400fGOA Phon0Ig1C111 O6 Fax: C, Iq-n C3�) OWNERS AFFIDAVIT: I certify that all of the information a I is application is correct and that all work will be done in compliance with all applicable law c ruction and zoning. PRINT OWNER OR CONTRACTOR NAME %�� NATURE OF OWNER OR CONTRACTOR STATE OF FLORIDA, COUNTY OF Va V v' j� ACKNOWLEDGED BEFORE ME THIS ` DAY OF`J 1 �, 20 j `% , BY � j WHO IS PERSONALLY KNOWN TO MEX OR WHO HAS PRODUCED AS E T F TI N. !lv�� ��Y SIGNATURE OF NOTAR COMMISSION NUMBER CaS� c t f- TYPE OR PRINT NAME OF NOTARY C.VAZOUEZ MY COMMISSION # EE 066309 EXPIAE81l0ebruary 21, 2015 Bonded Thru Notary Public Underwriters NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. EXEMPT: A/C -HEAT REPLACEMENT WITH CONTRACT UNDER $7500.00 Revised 04/26/2010 r wrightsoft, Project Summary Entire House Service America Air Conditioning 2755 NW 63rd Court, Fort Lauderdale, FL 33309 Phone: 954-979-1100 Fax: 954-977-3591 Web: www.serviceamerir-a.com For: Notes: Tahseen Izhar/ Fauzia Hussain 10125 Crosby Place, Port St. Lucie, FL 34986 Phone: 772-460-1717 Job: 3272295 Jun 05, 2012 dCrplalvett Weather: West Palm Beach, FL, US Winter Design Conditions Summer Design Conditions Outside db 47 OF Outside db 89 OF Inside db 70 OF Inside db 75 OF Design TD 23 OF Design TD 14 OF Daily range Relative humidity L 50 % Moisture difference 60 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 24316 Btuh Structure 44322 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 24316 Btuh Use manufacturer's data n Rate/swing multiplier 0.94 Infiltration Equipment sensible load 41663 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3666 Btuh Ducts 0 Btuh Heating Cooling Central vent (0 cfm) latent 0 Btuh Btuh Area (ft2) 2500 2500 Equipment load 3666 Volume (ft') 22500 22500 Air changes/hour 0.32 0.16 Equipment total load 45329 Btuh Equiv. AVF (cfm) 120 60 Req. total capacity at 0.70 SHR 5.0 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade Trade Model Cond 25HBC56OA003 AHRI ref no. Coil FX4DNF061T00 AHRI ref no.3646391 Efficiency 80 AFUE Efficiency 12.5 EER, 15 SEER Heating Input 0 Btuh Sensible cooling 39900 Btuh Heating output 0 Btuh Latent cooling 17100 Btuh Temperature rise 0 OF Total cooling 57000 Btuh Actual air flow 2016 cfm Actual air flow 2016 cfm Air flow factor 0.083 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.92 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2012-Jun-05 09:56:17 � `C wrightsoft® Right -Suite® Universal 2012 12.0.03 RSU10533 Page 1 CK W:\Wright Soft FPL Heat Loads - Cindy\Port St Lucie 3272295.rup Calc = MJ8 Front Door faces: N This combination qualifies for a Federal Energy Efficiency Tax Credit when placed in service between Feb 17, 2009 and Dec 31, 2011. AHRI Certified Reference Number: 3646391 Date: 6/4/2012 Product: Split System: Heat Pump with Remote Outdoor Unit -Air -Source Outdoor Unit Model Number: 25HBC560A**30 Indoor Unit Model Number: FX4DN(B,F)061 Manufacturer: CARRIER AIR CONDITIONING Trade/Brand name: BASE 15 PURON HP Manufacturer responsible for the rating of this system combination is CARRIER AIR CONDITIONING Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air -Conditioning and Air -Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): 57000 EER Rating (Cooling): 12.50 SEER Rating (Cooling): 15.00 Heating Capacity(Btuh)_r@ 47 F: 57000 Region IV HSPF Rating (Heating): 8.70 Heating Capacity(Btuh):@ 17 F,: - .354:00 . " Ratings followed by an asterisk (`) indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org, Air -Conditioning, Heating, click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on ROM QMand Refrigeration Institute which the certificate was issued, which is listed above, and the Certificate No., which is listed below. @2012 Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129832912166846020 Property appraiser - St.Lucif • "aunty, FL Page 1 of 1 PROPERTY RECORD CARD Tahseen Izhar Record: 1 of 1 —Prev Next » Spec.Assmnt Taxes Exemptions Permits Home Print Property Identification Site Address: 10125 Crosby PI ParcellD: 3327-710-0017-000-5 Sec/Town/Range: 33 :36S :39E Account #: 142195 y� < Map ID: 33/33N Land Use: SF Res Zoning: PUD City/Cnty: St Lucie County ' Ownership and Mailing Legal Description Owner: Tahseen Izhar Fauzia Hussain POD 26 AT THE RESERVE REPLAT CYPRESS POINT (PB 40-3) LOT Address: 10125 Crosby PI 115 (OR 1737-2461) Port St Lucie FL 34986-3051 Sales Information Assessment 2011 Final Total Land and Building Date Price Code Deed Book/Page 2011 Final: 291600 Land Value: 65600 Acres: 0.26 6/16/2003 369500 00 SP 1737 / 2461 Assessed: 291600 Building Value: 226000 1/1/1900 0 / Ag.Credit: 0 Finished Area: 2910 SgFt Exempt: 50000 Taxable: 241600 Taxes: 5112.5 BUILDING INFORMATION Exterior Features View: - RoofCover: TC - Clay Tile RoofStruct: HP - Hip ExtType: HB+ - HB+ YearBlt: 2002 Frame: Grade: B+ - B+ EffYrBlt: 2002 PrimeWall: BS - CB Stucco StoryHght: 0010 - 1 Story No.Units: 1 SecWall: Interior Features BedRooms: 3 Electric: MX - MAXIMUM PrmintWall: DW - Drywall FullBath: 3 HeatType: FHA - FrcdHotAir AvgHt/FI: 1/2Bath: 0 HeatFuel: ELEC - Electric Prm.Flors: CT - Tile -Ceramic %A/C: 100 %Heated: 100 %Sprinkled: 0 Special Features and Yard Items Land Information Type Y/S Qty. Units Qua]. Cond. YrBlt. No. Land Use Type Measure Depth SDSF - SITE DEV S-F Y 1 1 AV AV 2002 1 0100-SF Res BI -Site 1 ENC2 - POOL ENC-AVG Y 1 1351 AV AV 2002 SWAV - RES POOL AVG Y 1 450 AV AV 2002 PA01 - POOL DK-AVG Y 1 901 AV AV 2002 PHTR - POOL HEATER Y 1 1 AV AV 2002 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED. http://www.paslc.org/paslc/Pre.asp?prclid=332771000170005 6/4/2012 .:�Z29.. OFFICE USE ONLY: n DATE FILED: ( �� PERMIT # 1 REVISION FEE: S RECEH'T # 1. �r PLANNING & DEVELOP BUILDING & CODE REG T IVI 2300 VIRGINIA A FORT PIERCE, FL 6 (772) 462-155 + _tinm APPLICATION FOR BUILDI T PROJECT INFO v. LOCATION/SITE DDRE SSITE : 1012,15 Gros V�1 -PL 2. DETAILED DESCRIPTION OF PROJECT REVISIONS: �Q r P.A t+O 2-67t k k 14/ 3. 4. 61 CONTRACTOR INFORMATION: STATE of FL REG./CERT. #:C0 `- t" k ST BUSINESS NAME: QUALIFIERS NAME: jkl C lxv 1 J ADDRESS: 27 S A (0 3 ro C CITY: P�TL STATE: PHONE (DAYTIME): 9 Gi-1 Ci ) I M FA: OWNER/BUILDER INFORMATION: L NAME: a h S-e�;11Z V)c r ADDRESS: Iol 2 - Gros f-'L- CITY: RS STATE: PHONE: -77{0 2- 40- 1717 ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: STATE: PHONE (DAYTIME): SLCCC: 9/23/09 Revised 04/26/2010 Sion ).©ivy w UCIE COUNTY CERT. #: 2 (p (D 1 S FAX: FAX: ZH': ZIP: 06/13/2012 10:07 9549773t''=_ wrightsoft" - 2765 NW 0ard-606rt;FOA 4nuderd* -- - Winter - outside db - inside db Design TO Structure Ducts Central vent (0 1 Humidification Piping - Equipment load Cotlstruction qualit Fit'eplaces Area (ft") Volume (fit') Air changes/hour Equiv. A F (cfm) Heating E, Make Trade - Model AHRI ref no. Efficient Heating -Input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat t Summary House America Air Conditioning i`ahseen lzhar!-Fautia'Hussain 10126 GrosbY place Port'St. Lucie, FL 34986 Phone: 772-460-171`!VIM SERVICE AMERICA.' Job: _ 3272295 Date: -Jun 09, 2 11 y; e"Al PAGE 01/01 Weather- West Palm Beach, 1=L, USNV - - Summer_D_esign Conditions i Conditiortis 89- 'F- 47 of -outside db--- - 74 OF 2g 6F Inside db Design TgD Relat ve humidity 5a °!o Moisture' difference 60 grAb Sensible Cooling Equipment Load Sizing Summary 44322 Btuh 24316 Btuh 0 Stuh Structure Ducts . 0 Btuh 0 Stuh 0 Stuh Central Vent (0 cfm) Stuh 0 B 0 Btuh Blower 0 Stuh 24316 'Btuh Use manufacturer's data n 0.94 Ratelswing multiplier Equipment sensible load 41663 Btuh ation Simplified Latent Cooling Equipment Load Sizing -Average- 0 Structure - - - - - 0 13tuh Heating Cooling 250 Ducts . Central vent (0 cfm) Equipment latent load 0, Btuh' 86gg . Btuh 2500 2250D 22500 0.32 3p,16 Equipment total load Re_q, total capacity at 0.70 SHR 45329 BtGh 5.0 ton 60 Cooling Equipment Summary ant Summary Make Rheem Trade Cond - 14AJM60A01 Coll RBHP25J11SH7 AHRI ref n6.3620618 11.5 -EER, -EfEiclency 14.SEER 80 AFU.E 0 .Btuh- - ..Sensible coaling 38150 Stuh -16g50 Btuh - 0 Stuh 0 Latent cooling Total cogling 54600 Stuh 2016 oft - 2016 cfm 0.083 cfm/Stuh Actual air flow Air flow factor 0,045 cfmlBtuh 0 In H20 C to H2O Static:pressure Load sensible heat ratio 0.92 ge►tlllterle valuee haw been mnpuaiiy overridden Manual J Sth Ed. r^%era by ACCA to meet all requirements of -{�t- wrilghtso et-su IV°rent 2o1212.0.03 RGV1o833 P61 W:1Wr1ghCSoft FPS Heat lcifitl;o<18l Lucic 327229S.rup Cglc = MJB Front Doorla°es: N 201241n-03 11:33:00 Pepe 1