Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSR DATE: t>. Y JLI FEES DUE: �� � RECEIPT #: 5 q,J Permit #: =; W Planning & Development Services Department O Building & Code Regulation Division SC o 2300 Virginia Avenue Ft. Pierce, FL 34982-5652 S e Y Tel.772-462-1553 t �uCis, coo APPLICATION FOR ROOF PERMIT ty SEE REVERSE SIDE FO INSTRUCTIONS 1. Location/Site Address: �� 'Qa�e 7i r+U� , �o�� P�c�cG. �C-_ 3g1571 2. Parcel ID Number: 131a - 801- 0030' UDO -!t Office Use Section Townshi Ran a Ma Pa a zoning Land Use I Initials Only 3. Description of Project or Work Activity 4. Total Roof Area (square feet): Ll _"107 5. Roof Pitch: S 11 Q 6. Type of Roof: [ ✓rFiberglass Shingle [ ] Concrete Roof Tile [ ] Tar & Gravel [ ] Modified Bitumen [ ] Wood Shake / Shingle [ ] Other [ ] Product Approval required for all types of Roofing Material (2 Sets) ] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product Approval attached ** Roof Mitigation per F.S. 553.844 will be required. 7. Owner Information 8. Contractor Information Name: M0.r'I v✓, L F _ 40e ma-GIL Address: /gbq r&glL-'N✓. City:- R , R UCe. State: F-L Zip: 3y9S l Phone: i7a -5141- HS8 9. Value of Construction: $ 31 p� . °O FL Reg/Cert #: Ccr_ �Q County Cert #: Business Name: -772-,S61-088D Cell Phone: 77a- y'13- G317 "Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval. CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in co ance with all applicable laws regulating construction and zoning. RINT QUALIFIERS/OWNERS NAME GNATURE OF QUALIFIER/OWNER STATE OF FLORIDA, COUNTY OF ACKNOWLEDGED BEFORE ME THIS DAY OF r 1 C 20 BY. C WHO IS PERSONALLY WN TO ME OR HAS PR UCED AS IDENTIFICATION S GNAT R TA TYPE O RINT NAME OF NOTARY I (seal) COMMISSION NUMBER NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR R LE ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. B fy�"MpNRV " "' AwwwssloN# 116 20159 Revised4/26/2010 ,��0 y�c <_ Miy O)a Property Appraiser - St.Lucier r aunty, FL - :� Page 1 of 1 PROPERTY RECORD CARD Marjorie E Yormack Record: 1 of 1 <<Prev Next>> Spec.Assmnt Taxes Exemptions Permits Home Print Property Identification ;UCIE CO ' Site Address: 4804 Eagle Dr ParcellD: 1312-801-0030-000-9 G Sec/Town/Range: 13:34S :39E Account* 4473 , z Map ID: 13/13N ' Land Use: SF Res Zoning: RS-4 City/Cnty: St Lucie County Ownership and Mailing Legal Description Owner: Marjorie E Yormack HOLIDAY PINES S/D-PHASE II-B- LOT 227 (MAP 13/13N) (OR 2096- Address: 4804 Eagle Dr 1652) Fort Pierce FL 34951-2348 Sales information Assessment 2011 Final Total Land and Building Date Price Code Deed Book/Page 2011 Final: 115100 Land Value: 19300 Acres: 0.32 11/4/2004 269900 00 WD 2096 / 1652 Assessed: 115100 Building Value: 96800 4/24/1989 24400 05 WD 0635 / 2085 Ag.Credit: 0 Finished Area: 1854 SgFt 5/1/1981 0 01 CV 0369 / 1031 Exempt: 50000 12/1/1980 19300 00 CV 0345 / 1206 Taxable: 65100 Taxes: 1521.46 BUILDING INFORMATION Exterior Features View: - RoofCover: SA - Asph Shingle RoofStruct: HP - Hip ExtType: HC- - HC- YearBit: 1994 Frame: - Grade: C- - C- EffYrBit: 1994 PrimeWall: BS - CB Stucco StoryHght: 0010 -1 Story No.Units: 1 SecWall: - Interior Features BedRooms: 3 Electric: MX - MAXIMUM PrmintWall: DW - Drywall FullBath: 2 HeatType: FHA - FrcdHotAir AvgHt/FI: STD 1/2Bath: 0 HeatFuel: ELEC - Electric Prm.Flors: CU - Carpet %A/C: 100 %Heated: 100 %Sprinkled: 0 Special Features and Yard Items Land Information Type Y/S Qty. Units Qual. Cond. YrBlt. No. Land Use Type Measure Depth ENC2 - POOL ENC-AVG Y 1 792 AV AV 1994 1 0100-SF Res 255 -Front Ft 101 135.87 SWAV - RES POOL AVG Y 1 420 AV AV 1994 PA01 - POOL DK-AVG Y 1 372 AV AV 1994 3CFT- 3CFT S 1 1 AV AV 1994 3CFT- 3CFT S 1 1 AV AV 1994 SDSF - SITE DEV S-F Y 1 1 AV AV 2001 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED http://www.pasle.org/paslc/prc.asp?prclid=l31280100300009 6/5/2012 JOSEPH E. SMITH, CLERK-oF THE CIRCUIT COURT - SAINT LUCIE COL _ FILE # 3710851 OR B04, '396 PAGE 1602, Recorded 06/05/2012 D2:19 PM NOTICE OF COMMENCEMENT TO BE COMPLETED WHEN CONSTRUCTION VALUE EXCEEDS $2,500.00 OR WHEN HEATING OR AIR CONDITIONING REPAIR OR REPLACEMENT EXCEEDS $7,500.00 PERMIT #: TAX FOLIO #: 1312-801-0030-000-9 Stale of Florida, County of St Lucie, the undersigned hereby gives notice that Improvement will be made to certain real property, and In accordance with chapter 713, Florida statutes, the following information Is provided in this notice of Commencement, 1. LEGAL DESCRIPTION OF PROPERTY (AND STREET ADDRESS IF AVAILABLE): 4804 Eaale Or Fort Plerce Florida 34951-2348 Holiday Plnes S/D-Phase II-B- Lot 227 (Map 13/13N1(or 2096- 1652) 2. GENERAL DESCRIPTION OF IMPROVEMENT: Complete roof covering replacement 3. []OWNER INFORMATION or []LESSEE INFORMATION (If Lessee contracted for the Improvement) a. Name Marione E. Yonnack Address: 4804 Eaale Dr Fort Pierce, Florida 34951-2348 b. Interest in property: Owner c. Name and address of fee simple title holder (if other than owner): 4. CONTRACTOR: a. Name: Dependable Roofina Systems, Inc. Address: PO Box 650721, Vero Beach, FL 32965 b. Phone number: (7721569-0880 5. SURETY COMPANY (IF Applicable, a copy of the payment bond is attached): a. Name & Address: b. Phone number: Bond amount: 6. LENDER/MORTGAGE COMPANY: a. Name & Address: b. Phone number. 7. PERSONS WITHIN THE STATE OF FLORIDA DESIGNATED BY OWNER UPON WHOM NOTICES OR OTHER DOCUMENTS MAY BE SERVED AS PROVIDED BY SECTION 713.13 (1) (a) 7., FLORIDA STATUTES: a. Name & Address: b. Phone number, fax number: B. IN ADDITION TO HIMSELF OR HERSELF, a. Owner designates of to receive a copy of the lienor's notice as provided in section 713.13(1) (b), Florida statues. b. Phone number. 9. EXPIRATION DATE OF NOTICE OF COMMENCEMENT: (THE EXPIRATION DATE IS ONE (1) YEAR FROM THE DATE OF RECORDING UNLESS A DIFFERENT DATE IS SPECIFIED). WARNING TOOWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713. PART I, SECTION 713.13, FLORIDA STATUTES AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. UNDER PENALTIES OF PERJURY, I DECLARE THAT I HAVE READ THE FOREGOING AND THAT THE FACTS IN IT ARE TRUE TO THE BEST OF MY KNOWLEDGE AND BELIEF (SECTION 92.525, FLORIDA STATUTES �G.l�IDh.tJ✓ G . �Ls�2 rriuG�J SIGNATURE16F OWNER or LRISIE or OWNER'S AUTHORIZED OFFICER/DIRECTOR/PARTNER/MANAGER V Owner SIGNATORY'S TITLE/OFFICE THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME THIS �DAY OF 20L BY: MA R%d e AS Owner FOR Self NAME OF PERSON TYPE OF AUTHORITY NAME OF PARTY ON BEHALF OF WHOM INSTRUMENT WAS EXECUTED ❑PERSONALLY KNOWN OR30PRODUCEDIDENTIFICATION TYPE OFIDENTIFICATION PRODUCED LTTR/tla)P_4 L/drNd/.SL— .� Jo C . Le lv 2/ ��.. ;- , JW c.181a . t IJYCOHLIISSION10DIp1110 OT SIG NOTARY PRINTED NAME NOTARY SEAL �*F EXPIRES: Juao 5, 2Dt3 STATE 0 FLORIDA ST• LUCIE COU'NTY THIS IS TO CERTIFYTHATTHIS IS TRUE A40.CORRECT COPY OFTµE ` �` F cT ORIQFP�AE � OS H E SMITH, CLERK r By. m Deputy lerk '' Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 772-462-2165 or 772-462-2172 Fax: 772-462-6443 ROOF INSPECTION AFFIDAVIT Re: Permit # 1-,7 O = L/Wq I, C4-a'(/L' licensed as a(n)Contractor*/Engineer/Architect ( lease print name & circle license type) *F$468 Building Inspector 'General, Building, Residential or Roofing Contractor or any individual certified under 468 F.S. to make such an inspection. On or about 6 I I l2 Ft— , I did personally inspect the roof deck nailing (Date) work at: 011 r r,5,t4 P;el-6E.,.> /e'l (Job site address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S.) it/Ot� Signature and Seal STATE OF FLORIDA COUNTYOF �✓�� "iC-jr License # Sworn to and subscribed before me this 11 day of 131, N1C 20J- by_F-0-1 VL Z,! CO�'0'Who is ep rsotilly known to me orwho has produced as identification."' RECEIVED Notary Public, State of Florl JUN 1 2012 Signature of Notary: V~—.. Commission Number: (Seal) En 01/19/2011 tian�au:J-:, ^BETTYL.OU ROBERTS MY COMMIMON # DD849864 EXPIRES Januarys 07, 2013 d0i)99U-07-i5 FWISduWp�grySdrvito.aom TO/TO 30Vd ONId00d 3-19VGN3d3G 899066ZZLL ZT:VT ZTaZ/TT/90 Florida Building Code Online r + Page 1 of 2 it C S ff .'IS S't Ma Links Search 3 i*^ € %!�)anrmw lAntl BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts , Publications — to e p usines rpY�'` �=P Product Approval Professi I II USER: Public User Regulation Prod iyE Approv_ai Menu > Product or AnolicaCipn Search > A�Itcaiiion l;is; > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By FL10674-R6 Revision 2010 Approved e'0PV j FILE ["2;`0PY Owens Corning One Owens Corning Parkway Toledo, OH 43659 (740)404-7829 greg.keeler@owenscorning.com Greg Keeler greg.keeler@owenscorning.com Mel Sancrant 1 Owens Corning PKWY Toledo, OH 43659 (419)376-8360 mel.sancrant@owenscornig.com Roofing Asphalt Shingles Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer (_ Evaluation Report - Hardcopy Received Robert J.M. Nleminen PE-59166 Underwriters Laboratories Inc. 09/26/2014 John W. Knezevich, PE Validation Checklist - Hardcopy Received FL10674 R6 COI Trinity ERq CI - Nieminen.odf Standard Year ASTM D3161, Class F 2006 ASTM D3462 2007 ASTM D7158, Class H 2O07 http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5 V%2b... 6/5/2012 Florida Building Code Online Page 2 of 2 Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved mary of Products Method 1 Option D 02/16/2012 02/21/2012 02/24/2012 04/03/2012 FL # Model, Number or Name IlDescription 10674.1 Owens Corning Asphalt Roofing 3-tab, laminated, starter, and hip & ridge Shingles and Starters Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Installation Instructions FL10674 R6 II er020612FINAL OC FL10674- R6 Asphalt Shingles,odf Verified By: Robert J. M. Nieminen PE - 59166 Created by Independent Third Party: Yes Other: Refer to ER, Section 5. Evaluation Reports FL10674 R6 AE er02061.2FINAL OC FL10674- R6 Asphalt Shingles.p,df - Created by Independent Third Party: Yes Next Contact Us :: 1940 North Monroe Street, Tallahassee FL 32M Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Copyright 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, e-mail addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions regarding DBPR's ADA web accessibility, please contact our Web Master at webmaster(-)dbor.state.fl.us. Product Approval Accepts: is WN 0 go securk 'LS'4�:ty;�sS'?y' V6k(Si�ii http://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5 V%2b... 6/5/2012 RD EVALUATION REPORT EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 Owens Corning Evaluation Report 037940.02.12 One Owens Corning Parkway FL10674-R6 Toledo, OH 43659 Date of Issuance: 02/06/2012 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the. Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2010 FBC and 2010 FBC Residential Volume sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 02/06/2012 This does not serve as an electronically signed document. Signed, sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does,not have, nor does It intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. TrinitylERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. TRINITYIERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2007 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161, Class F 2006 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158, Class H 2O07 3. REFERENCES: Entity Examination Reference Date UL (CER1739) Physicals & Wind Resistance File R2453, Vol. 3 02/15/2007 UL (TST1740) Physical Properties 06CA20263 04/18/2006 Miami -Dade (CER1592) FBC HVHZ Compliance 07-1116.12 02/14/2008 Miami -Dade (CER1592) FBC HVHZ Compliance 09-0915.12 12/16/2009 Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.09 10/27/2010 Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.10 10/27/2010 Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.08 10/27/2010 Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.07 10/27/2010 Miami -Dade (CER1592) FBC HVHZ Compliance 11-0411.03 06/16/2011 Miami -Dade (CER1592) FBC HVHZ Compliance 11-0919.05 10/13/2011 UL (QUA1743) Quality Control Service Confirmation Exp. 09/26/2014 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic° and Supreme° are fiberglass reinforced, 3-tab asphalt roof shingles. 4.1.2 Berkshire° are fiberglass reinforced, 4-tab asphalt roof shingles. 4.1.3 Duration®, Duration° Premium, Oakridgeo and WeatherGuard° HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 BerkshireO Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant and WeatherGuard° HP Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.3 Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ. 5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.3 Wind Classification: 5.3.1 / All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for us in all wind zones up. to Vasd = 150 mph (V,it = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. Exterior Research and Design, LLC. Evaluation Report 037940.02.12 Certificate of Authorization #9503 FL10674-116 Date of Issuance: 02/06/2012 Page 2 of 6 s IN ITY ERD 5.3.2 All Owens Corning hip & ridge shingles and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for us in all wind zones up to Vasa = 150 mph (V„it = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.3.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.3.4 Refer to Owens Corning published information on wind resistance and installationlimitations. 5.4 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 9N-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 9N-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: ➢ Berkshire° shingles require minimum five (5) nails per shingle. ➢ WeatherGuard° HP shingles require minimum six (6) nails per shingle. ➢ Starter Strip Plus requires minimum five (5) nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. 6.2.5 Minimum Nailing — Classic@ & Supreme: Normal Mamootd.or Area par; Wind Areas H%h'�M ad dosvones y Area pars vfontos normates- Areas viontoa f;artes (A) t 2• B? t L �! V Exposaro Expasleidn Exterior Research and Design, LLC. Certificate of Authorization #9503 Norman Mansard or Area pain Wind Areas High VOW dosysnes y Area, para vlentos normeles Areas vfentoe fuertes 1• 2' IBA 2` 21 t'�G �121 r. wi ' Exposure Exposlaldn Evaluation Report 037940.02.12 FL10674-R6 Date of Issuance: 02/06/2012 Page 3 of 6 6.2.6 Minimum Nailing - Berkshire@: 6.2.7 NV 6.2.8 1 Sealanfstrip. la2iradeselladoY. &Yt' 9Yf ' 9•v}' BYi'�' } i Nailing - Duration@ & Duration@ Premium: 4 Nall-Pattem Esquema de 4 davov, . ;Swe•eaail°tastenlogaleawidth` .. __... _.. de elawsSureNaila 9 f rl¢ 4f 6Ye Exposure Nails W Exposure 6Yptrlg.de,exppskt4n 'Gairor. 6H,ptilg.c?eexpbs(ol6n. linimum Nailing - Oakridge@: 4Nail Patfem Es4ueMa'P9it 4-elavos 7r 1e; 'I-*— ir' =y►1 H� tz =1►1 ` 5 fits" Exposure Nails S 5/8 Exposure Erpcslcfgri4sb5/Bpu14•,. CfaYos Exposta4irtda55/Bpufg.• ("•-'" ITR IT . , ER _SureflaL''a.'-SNeYbiP :tasisnln� 3113W�A tastmin99• 8leawitllA AreadB _ � �P.' �. - \1 Neida S aNSJ+^' . �_ `12` ^i► \ � ^ n2' �suuHaiP 5ib'.' Exposure,. 'Nails 5^hpufg. do erposlel4u Claws SW Exposure 5% ping. de exppstet4n S'NaIIPztCera` Esguema;op 6;cl�vos' Nall$. 5:518" Exposuree Gasps 6: big" Ezposu�a, Ezposl8f6p ile 66/8 pufg. Expos(clbn de 65/8 ping. Exterior Research and Design, LLC. Evaluation Report 037940.02.12 Certificate of Authorization #9503 FL10674-R6 Date of Issuance: 02/06/2012 Page 4 of 6 6.2.9 Minimum Nailing - WeatherGuard@ HP: is"Btil. sift %%w yr kftl ►• r�lwe7�rdr'Nil u. C�wYYlre i };d(Ir 6.3 Hip & Ridge Shingles: 6.3.1 Installation of Berkshire° Hip and Ridge Shingles, High Ridge, Hip & Ridge with Sealant and WeatherGuard® HP Hip and Ridge Shingles shall comply with the manufacturer's current published instructions, using four (4) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand -sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing - Berkshire@ Hip & Ridge and High Ridge: Fig. 1 4 t— Preva!lingWind• \\\ OirediohA \... Nails A' yQ Exposure 6.3.4 Minimum Nailing - Hip & Ridge with Sealant: itteirn Fig. 2 - fthi,W W Fastelning Pattern: i 9014) rim ° Shingle ncl :Discalrc!' ;2 .:2,r; 6c ,ire�r SS#ri P 12" ' Fas#enngS°Exposure D�s�noe Exterior Research and Design, LLC. Evaluation Report 037940.02.12 Certificate of Authorization #9503 FL10674-R6 Date of Issuance: 02/06/2012 Page 5 of 6 6.3.5 Minimum Nailing — WeatherGuard® HP Hip and Ridge: Fg..A fN q 4 Preuailing WInC -- Dlredlon A Nails' 'T"? 1 p I' I R I I I I P I I' I \ A I I I 5 — ' 'Expgsuro 7. LABELING: Fig. C Hip:& Ridge Shingle fastening TopView' Nails Nall$ 7 2" 2" I. t" 61 'Exposure 1: 12' 7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. S. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: Underwriters Laboratories — QUA1743; (414) 248-6409; karen.buchmann@ul.com - END OF EVALUATION REPORT. - Exterior Research and Design, LLC. Evaluation Report 037940.02.12 Certificate of Authorization #9503 FL10674-116 Date of Issuance: 02/06/2012 Page 6 of 6 Florida Building Code Online Page 1 of 2 25i 4.°Et... �� g y�� .,f ,4trXa d►er li •! 9 y§ tD 9 4j'S a..,o,.....zu"5'.f'..rytts.._..._.._,__cF.6 fr-a`w�wf...«,>, ,,.'f .. ♦..' rt C'; ;iiGd DeptlneriitL'' BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search Busines �������� Product Approval P (1i"111 - —�,( USER: Public User Regulation Produc A proyai Menu > Product or Applic4tlon Search > Appligation Ust > Application Detail FL # Application Type _�¢ ����," Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) FL5259-R14 Revision 2010 Approved POLYGLASS USA 150 Lyon Drive Fernley, NV 89408 (570)384-1230 Ext242 jakins@polyglass.com James Akins jakins@polyglass.com Steve Wadding 150 Lyon Drive Fernley, NV 98408 (602)363-7139 stevew@polyglass.com James Akins 555 Oakridge Road Humboldt Industrial Pkwy Hazleton, PA 18201 (800) 894-4563 jakins@polyglass.com Roofing Underlayments Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer r Evaluation Report - Hardcopy Received Robert Nieminen PE-59166 Underwriters Laboratories Inc. 11/30/2012 John W. Knezevich, PE 2 Validation Checklist - Hardcopy Received FL5259 R14 COI Trinity ERD CI - Nieminen.odf Standard Year ASTM D1970 2001 ASTM D226 2006 ASTM D6164 2005 http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvbSgAaZp3 Crk2... 6/5/2012 Florida Building Code Online Page 2 of 2 ASTM D6222 2002 ASTM G154 2005 ASTM G155 2005 FM 4474 2004 FRSA/TRI07320 2005 TAS 103 1995 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 12/09/2011 Date Validated 12/15/2011 Date Pending FBC Approval 12/20/2011 Date Approved 01/31/2012 Date Revised 04/23/2012 ............... _....__.__.._.._.--...._... CSummary of Products FL # Model, Number or D escription Name 5259.1 Polyglass Roof Roofing underlayments Underlayments Limits of Use Installation Instructions Approved for use In HVHZ: No FL5259 R14 II er120611FINAL POLYGLASS UNDERLAYMENTS FL5259- R14.Ddf Approved for use outside HVHZ: Yes Verified By: Robert Nieminen PE-59166 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-622.5 Evaluation Reports Other: 1.) The design pressure in this FL5259 R14 AE er120611FINAL POLYGLASS UNDERLAYMENTS FL5259- R14. d application relates to one particular underlayment system for use under Created by Independent Third Party: Yes foam -on tile systems. Refer to ER Section 5.5.2 for other systems and maximum design pressures. 2.) Refer to ER Section 5 for other limits of use. Back Next Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: SSO-487-1824 The State of Florida is an AA/EEO employer. copyright 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, e-mail addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions regarding DBPR's.ADA web accessibility, please contact our Web Master at webmaster(aidbor.state.Fl.us. Product Approval Accepts: "] ® sChzS.: El �s,VNLrfcw\ St'GUtZt i'CjitC:°S° •pc��z!�� nY' yar'i52ye1 http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvbSgAaZp3 Crk2... 6/5/2012 '�T�,��RINITYJERD EVALUATION REPORT Polyglass USA, Inc. 150 Lyon Drive Fernley, NV 98408 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 Evaluation Report P12060.02.09-R9 FL5259-R14 Date of Issuance: 02/24/2009 Revision 9: 12/06/2011 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2010 Florida Building Code sections noted herein. DESCRIPTION: Polyglass Roof Underlayments LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 10. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nleminen, P.E. on 12/06/2011 This does not serve as an electronically signed document. Signed, sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial Interest in any company manufacturing or distributing products it evaluates. 2. TrinitylERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. iR.o� ;ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.3, 1507.3.3, 1507.5.3, Physical Properties ASTM D226 2006 1507.7.3, 1507.8.3, 1507.9.3 1507.2.4, 1507.2.9.2, 1507.3.3, Physical Properties ASTM D1970 2001 1507.5.3 1507.11.2 Physical Properties ASTM D6164 2005 1507.11.2 Physical Properties ASTM D6222 2002 1504.6 Accelerated Aging ASTM G154 2005 1504.6 Accelerated Aging ASTM G155 2005 1504.3.1 Wind Uplift FM 4474 2004 1507.3.3 Installation Practice FRSA/TRI 07320 2005 1523.6.5.2.1 Physical Properties TAS 103 1995 3. REFERENCES: Entity Examination Reference Date FM Approvals (TST 1867) Wind Uplift 3004091 01/12/2000 PRI (TST 5878) Physical Properties PRI01111 04/08/2002 PRI (TST 5878) Physical Properties PUSA-005-02-01 01/31/2002 PRI (TST 5878) Physical Properties PUSA-013-02-01 12/23/2002 PRI (TST 5878) Physical Properties PUSA-013-02-02 12/23/2002 PRI (TST 5878) Physical Properties PUSA-013-02-03 12/23/2002 PRI (TST 5878) Physical Properties PUSA-018-02-01 07/14/2003 PRI (TST 5878) Physical Properties PUSA-028-02-01 07/13/2005 PRI (TST 5878) Physical Properties PUSA-033-02-01 01/12/2006 PRI (TST 5878) Physical Properties PUSA-035-02-01 09/29/2006 PRI (TST 5878) Physical Properties PUSA-055-02-02 12/10/2007 PRI (TST 5878) Physical Properties PUSA-061-02-02 01/28/2008 PRI (TST 5878) Physical Properties PUSA-076-02-01 02/22/2008 PRI (TST 5878) Physical Properties PUSA-083-02-01 04/14/2008 PRI (TST 5878) Physical Properties PUSA-088-02-01 07/29/2009 MTI (TST 2508) Physical Properties JX20H7A 04/01/2008 MTI (TST 2508) Physical Properties RX14E8A O1/29/2009 ERD (TST 6049) Physical Properties 11752.09.99-1 02/08/2000 ERD (TST 6049) Wind Uplift 11776.06.02 01/16/2003 ERD (TST 6049) Physical Properties 02200.07.03 07/14/2003 ERD (TST 6049) Wind Uplift P1740.01.07 01/04/2007 ERD (TST 6049) Physical Properties P5110.04.07-1 04/11/2007 ERD (TST 6049) Wind Uplift P9260.03.08 03/21/2008 ERD (TST 6049) Physical Properties P13450.08.09 08/13/2009 ERD (TST 6049) Wind Uplift P30540.11.09-R1 11/30/2009 ERD (TST 6049) Physical Properties P33360.06.10 06/25/2010 Exterior Research and Design, LLC. Evaluation Report P12060.02.09-119 Certificate of Authorization #9503 FL5259-R14 Revision 9: 12/06/2011 Page 2 of 10 Entity ERD (TST 6049) ERD (TST 6049) ICC-ES (EVL 2396) Miami -Dade (CER 1592) Polyglass USA Polyglass USA Polyglass USA UL (QUA1743) 4. PRODUCT DESCRIPTION: Examination Physical Properties Physical Properties IBC Compliance HVHZ Compliance Manufacturing Affidavit P/L Affidavit Materials Affidavit Quality Control 4.1 Mechanically Fastened Underlavments: T I ITYIERD Reference Date P33370.03.11 03/02/2011 P33370.04.11 04/26/2011 ESR-1697 11/01/2009 NOA Current Products Current 02/18/2009 Mule -Hide Cross Ltg 03/01/2008 Polystick SA Compound 08/18/2011 File No. R14571, Vol 1 Exp. 11/30/2012 4.1.1 ELASTOBASE is a fiberglass reinforced, SBS modified bitumen base sheet. 4.1.2 ELASTOBASE P is a polyester -reinforced, SBS modified bitumen base sheet. 4.2 Self -Adhering Underlavments: 4.2.1 POLYSTICK MTS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced with polyolefinic film surface; meets ASTM D1970 and TAS 103. 4.2.2 POLYSTICK IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an aggregate surface; meets ASTM D1970. 4.2.3 POLYSTICKTU is a nominal 100-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a granular surface; meets ASTM D1970 and TAS 103. 4.2.4 POLYSTICK TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a polyester fabric surface; meets ASTM D1970 and TAS 103. 4.2.5 POLYSTICK TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass- fiber/polyester reinforced, with a granular surface; meets ASTM D1970 and TAS 103. 4.2.6 POLYFLEX SAP, PoLYFLEX SAP FR, MULE -HIDE SA-APP CAP SHEET AND MULE -HIDE SA-APP CAP SHEET (FR) are a polyester reinforced, APP modified bitumen cap sheets. 4.2.7 DUAL PROTM is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membranes, fiberglass reinforced, with a polyester fabric surface. 4.2.8 TILE PROTM is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membranes, fiberglass reinforced, with a polyester fabric surface. 4.3 Mechanically Fastened and/or Bonded Underlavments: 4.3.1 ELASTOFLEx S6G AND ELASTOFLEx S6G FR are polyester reinforced, SBS modified bitumen cap sheets. 4.3.2 POLYFLEx G AND POLYFLEx G FR are polyester reinforced, APP modified bitumen cap sheets. 5. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ. 5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.3 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the AHJ for approval based on this evaluation combined with supporting data for the prepared roof covering. Exterior Research and Design, LLC. Evaluation Report P12060.02.09-119 Certificate of Authorization #9503 F1_5259-R14 Revision 9: 12/06/2011 Page 3 of 10 5.4 Allowable roof covers aDDlied atop the underlavments are as follows: Table 1: Roof Cover Options Underlayment Asphalt Nail -On Tile Foam -On Metal wood Shakes & Slate Shingles Tile Shingles Elastobase Yes Yes No Yes Yes Yes Elastobase P Yes Yes No Yes Yes Yes Polystick MTS Yes Yes No Yes Yes Yes Polystick IR-Xe Yes No No No Yes Yes Polystick TU Yes Yes es No Yes Yes See 5.Polystick TU P Yes Yes es No Yes Yes See 5.Polystick TU Plus Yes Yes es Yes Yes Yes See 5.Dual Pro Yes Yes No Yes Yes Yes Tile Pro Yes Yes es Yes Yes Yes See 5.Elastoflex S6G or S6G FR Yes Yes No No Yes Yes Polyflex G or G FR Yes Yes es No Yes Yes See 5.Polyflex SAP or SAP FR Yes Yes es No Yes Yes See 5.Mule-Hide SA-APP Cap Sheet Yes Yes Yes No Yes Yes or SA-APP Cap Sheet (FR) See 5.4.1 5.4.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives unless tensile adhesion / long term aging data from an accredited testing laboratory is provided. ➢ Polyfoam PolyPro AH160: Polystick TU, Polystick TU P, Polystick TU Plus, Polyflex G, Polyflex G FR, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule - Hide SA-APP Cap Sheet (FR) or Tile Pro. ➢ Dow TileBond: Polystick TU P, Polyflex SAP or Tile Pro 5.4.2 For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the tile. 5.4.3 A 2-ply underlayment system, consisting of Polystick MTS followed by Polystick MTS, TU, TU P or TU Plus, or Polyflex SAP is allowable for use under mechanically attached prepared roof systems. This is not a requirement, but is allowable if a 2-ply underlayment system is desired. Exterior Research and Design, LLC. Evaluation Report 11312060.02.09-119 Certificate of Authorization #9503 FL5259-R14 Revision 9: 12/06/2011 Page 4 of 10 5.5 Allowable substrates are noted below: 5.5.1 Direct -Bond to Deck: Polystick, Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: ➢ New untreated plywood; ➢ ASTM D41 primed new untreated plywood; ➢ Existing plywood; ➢ ASTM D41 primed existing plywood; ➢ ASTM D41 primed OSB; ➢ Southern Yellow Pine; ➢ ASTM D41 primed Southern Yellow Pine; ➢ ASTM D41 primed structural concrete; ➢ Huber Engineered Woods "ZIP System" Panels (designed and installed to meet wind loads for project). Note: Polyglass does not require priming of new or existing plywood sheathing. New or existing plywood sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes. Elastoflex S6G or S6G FR in hot asphalt to: ➢ ASTM D41 primed structural concrete. Polyflex G or G FR torch -applied to: ➢ ASTM D41 primed structural concrete. 5.5.2 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI 07320 does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI 07320 and are used in foam -on the applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609.1.5 for determination of design wind pressures. 5.5.2.1 Maximum Design Pressure = -622.5 Psf. Deck: Structural concrete to meet project requirements to satisfaction of AHJ. Primer: ASTM D41 Underlayment: Polyflex G or G FR torch -applied. 5.5.2.2 Maximum Design Pressure = -315 psf. Deck: Structural concrete to meet project requirements to satisfaction of AHJ. Primer: ASTM D41 Underlayment: Polystick TU, Polystick TU P, Polystick TU Plus, Tile Pro, Polyflex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR). 5.5.2.3 Maximum Design Pressure = -135 psf. Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Primer: (Optional) ASTM D41 Joints: Min. 4-inch wide strips of Elastoflex SA-V over all plywood joints. Underlayment: Polystick TU, Polystick TU P, Polystick TU Plus, Polyflex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) Exterior Research and Design, LLC. Evaluation Report 1312060.02.09-119 Certificate of Authorization #9503 FL5259-1114 Revision 9: 12/06/2011 Page 5 of 10 I INITY f ERQ 5.5.2.4 Maximum Desian Pressure = -90 psf. Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Primer: (Optional) ASTM D41 Underlayment: Polystick TU, Polystick TU P, Polystick TU Plus, Polyflex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) 5.5.2.5 All other direct -deck, adhered Polyglass underlayment systems beneath foam -on tile systems carry a Maximum Design Pressure of -45 psf. 5.5.3 Bond -to -Insulation: ➢ Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: ASTM C1289, Type II, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; DensDeck DuraGuard; DensDeck Prime; or SECUROCK Gypsum -Fiber Roof Board. ➢ Elastoflex S6G or S6G FR in hot asphalt to: DensDeck. Prime or SECUROCK Gypsum -Fiber Roof Board. ➢ Polyflex G or G FR torch -applied to: ASTM D41 primed structural concrete; DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on the systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4470, Appendix K or TAS 114, Appendix I 5.5.4 Bond to Mechanically Attached Base Layer: ➢ P.olystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or Tile Pro self -adhered to: ASTM D226, Type I or II felt; Elastobase; Elastobase P or Mule -Hide Nail Base. ➢ Elastoflex S6G or S6G FR in hot asphalt to: ASTM D226, Type I or II felt; Elastobase; Elastobase P or Mule -Hide Nail Base. ➢ Polyflex G or G FR torch -applied to: Elastobase; Elastobase P or Mule -Hide Nail Base. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam -on tile systems, base layer shall be attached per minimum requirements of FRSA/TRI 07320/8-05 or RAS 120. 5.6 Exposure Limitations: 5.6.1 Elastobase, Elastobase P, shall. not be left exposed for longer than 30-days after installation. 5.6.2 Polystick IR-Xe, Dual Pro or Tile Pro shall not be left exposed for longer than 90-days after installation. 5.6.3 Polystick MTS, TU, TU P or TU Plus shall not be left exposed for longer than 180-days after installation. 5.6.4 Polyflex SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure limitation, unless the prepared roof covering is to be adhesive -set tile, in which case the maximum exposure is 30 days. 5.6.5 Elastoflex S6G or S6G FR or Polyflex G or G FR does not have an exposure limitation, unless the prepared roof covering is to be adhesive -set the (Polyflex G or G FR only), in which case the maximum exposure is 180 days. Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R9 Certificate of Authorization #9503 FL5259-1114 Revision 9: 12/06/2011 Page 6of10 I TRIG 1 IRd i 5.7 For tile roof installations governed by the FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, use is limited to the following. Reference is made to the FRSA/TRI Technical Brief titled "Florida High Wind Roof Tile Self -Adhered Underlayment Requirements as of 02/14/2011" for limitations for self -adhering underlayments used beneath the roof systems. Table 2: Tile System Options per FRSA/TRI 07320/8-05 System Underlay Option Section Reference Product(s) 3.02A 1 Batten Modified Cap Sheet Elastoflex S6G or Elastoflex S6G FR; Polyflex G or G FR only No. 30 /Modified Cap Base Layer: Elastobase; Elastobase P System One: 2 3.02B Sheet Top Layer: Elastoflex S6G or Elastoflex S6G FR; Polyflex G Mechanically or G FR Fastened Tile, 4 3.02D No. 30 Elastobase; Elastobase P Unsealed or Sealed Self -Adhered Polystick MTS; TU; TU P; TU Plus; Polyflex SAP or SAP FR; Underlayment 5 3.02E Underlayment SA-APP Cap Sheet or SA-APP Cap Sheet (FR); System Dual Dual Pro; Tile Pro Base Layer: ASTM D226, Type II; Elastobase; Elastobase P; No. 30 / Self -Adhered Mule -Hide Nail Base 6 3.02E Underlayment Top Layer: Polystick MTS; TU; TU P; TU Plus; Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR); Dual Pro; Tile Pro 3.02A 1 Batten Modified Cap Sheet Elastoflex S6G or Elastoflex S6G FR; Polyflex G or G FR only No. 30 / Modified Cap Base Layer: Elastobase; Elastobase P System Two: 2 3.026 Sheet Top Layer: Elastoflex S6G or Elastoflex S6G FR; Polyflex G Mechanically or G FR Fastened Tile, Self -Adhered Polystick TU; TU P; TU Plus; Polyflex SAP or SAP FR; Mule - Sealed 4 3.02D Underlayment Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR); Dual Underlayment Pro; Tile Pro System Base Layer: ASTM D226, Type II; Elastobase; Elastobase P; No. 30 / Self -Adhered Mule -Hide Nail Base 5 3.02E Underlayment Top Layer: Polystick TU; TU P; TU Plus; Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro; Tile Pro 1 3.02A Modified Cap Sheet Polyflex G or G FR System Four 2 3.02B No. 30 / Modified Cap Base Layer: Elastobase; Elastobase P Sheet Top Layer: Polyflex G or G FR Adhesive -Set 4 3.021D Self -Adhered Polystick TU; TU P; TU Plus; Polyflex SAP or SAP FR; Tile Tile, Unsealed or Underlayment Pro; Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Sealed Base Layer: ASTM D226, Type II; Elastobase; Elastobase P; Underlayment No. 30 / Self -Adhered Mule -Hide Nail Base System 5 3.02E Underlayment Top Layer: Polystick TU; TU P; TU Plus; Polyflex SAP or SAP FR; Tile Pro; Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR) 1 3.02A No. 30 / Modified Cap Base Layer: ASTM D226, Type II; Elastobase; Elastobase P Sheet Top Layer: Polyflex G or G FR System Four 3 3.02C Self -Adhered Polystick TU; TU P; TU Plus; Polyflex SAP or SAP FR; Tile Adh Adhesive -Set Underlayment Pro; Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Base Layer: ASTM D226, Type II; Elastobase; Elastobase P; Tile, Sealed Underlayment No. 30 / Self -Adhered Mule -Hide Nail Base System 4 3.02D Underlayment Top Layer: Polystick TU; TU P; TU Plus; Polyflex SAP or SAP FR; Tile Pro; Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1119 Certificate of Authorization #9503 FL5259-1114 Revision 9: 12/06/2011 Page 7of10 6. INSTALLATION: 6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 Elastobase. Elastobase P or Mule -Hide Nail Base: 6.3.1 Shall be installed in compliance with the codified requirements for ASTM D226, Type II underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.3.2 For use in non -tile applications: 6.3.2.1 Reference is made to the current edition of the NRCA Steep -slope Roofing Manual and ARMA recommendations for installing shingle underlayments and flashings 6.3.2.2 Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), Dual Pro or Tile Pro, self -adhered, Elastoflex S6G or S6G FR in hot asphalt or Polyflex G or G FR, torch applied. 6.3.3 For use in tile applications, reference is made to Polyglass published installation instructions in conjunction with FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein. 6.4 Polystick MTS, IR-Xe, TU _TU P or TU Plus, Polvflex SAP or SAP FR. Mule -Hide SA- APP Cap Sheet or SA-APP Cap Sheet (FR), Dual Pro or Tile Pro: 6.4.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.4.2 For non -tile applications: 6.4.2.1 All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) should be back -nailed in selvage edge seam in accordance with Polyglass / Mule -Hide Back Nailing Guide. Nails shall be corrosion resistant, 11 gauge ring -shank type with a minimum 1-inch diameter metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back - nailed using the above noted fasteners and spacing, in area marked "nail area, area para clavar" on the face of membrane. The head lap membrane is to cover the area being back - nailed 6.4.2.2 All seal -lap seams (selvage laps) must be firmly rolled with a minimum 28 lb. hand roller to ensure full contact and adhesion. For Dual Pro and Tile Pro, align the edge of the top sheet to the end of the glue pattern (the sheet will overlap the fabric). Exterior Research and Design, LLC. Evaluation Report P12060.02.09-119 Certificate of Authorization #9503 FL5259-1114 Revision 9: 12/06/2011 Page 8 of 10 �R0 I ERD i View of Ovelap Seam of Dual Pro and Tile Pro 6.4.2.3 All over -fabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Polystick TU Plus Tile Underlayment Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Electrometric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic, applied in between the application of the lap. 6.4.2.4 Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details 6.4.2.5 Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Polystick TU Plus Tile Underlayment Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic to the area in need of repair, followed by a minimum 6 x 6 inch patch of the Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be installed in a water shedding manner. 6.4.2.6 All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied for the field membrane. Hand rollers are acceptable for rolling of patches, laps (min. 28 lb roller) or small areas of the roof that are not accessible to a large roller or broom. 6.4.3 For tile applications (not allowed for Polystick IR-Xe): 6.4.3.1 Reference is made to Section 6.4.2 herein in conjunction with FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein, using the instructions noted above as a guideline. 6.4.3.2 For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the tile. Exterior Research and Design, LLC. Evaluation Report P12060.02.09-119 Certificate of Authorization #9503 FL5259-1114 Revision 9: 12/06/2011 Page 9of10 6.5 Elastoflex S6G or S6G FR: 6.5.1 Elastoflex S6G or S6G FR shall be installed in compliance with current Polyglass published installation requirements. For use in nail -on tile applications, reference is made to FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein. 6.5.2 Elastoflex S6G or S6G FR shall be fully asphalt -applied to the substrates noted in Section 5.5. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, and off set end -laps minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge. 6.6 Polyflex G or G FR: 6.6.1 Polyflex G or G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications, reference is made FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein. 6.6.2 Polyflex G or G FR shall be fully asphalt -applied to the substrates noted in Section 5.5. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, and off set end -laps minimum 3 feet from course to course. Side and end laps shall be fully heat -welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge. 6.7 Tile Staging: 6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Polyglass published requirements for tile staging.. 6.7.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRI 07320/8- 05 must be used on all roof slopes greater than 7:12. For roof slopes in excess of 61/4:12, precautions should be taken, such as the use of battens, to prevent tile sliding during the loading process. 6.7.3 For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the tile. 6.7.4 The minimum cure time after installation of self -adhering membranes and before loading of roofing tiles is forty-eight (48) hours. 7. LABELING: Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. S. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. Rule 9N-3 QA requirements 10. QUALITY ASSURANCE ENTITY: Underwriters Laboratories - QUA1743; (314) 578-3406; k.chanceilor@us.ul.com - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report P12060.02.09-119 Certificate of Authorization #9503 FL5259-1114 Revision 9: 12/06/2011 Page 10 of 10