DATE: t>. Y JLI FEES DUE: �� � RECEIPT #: 5 q,J Permit #:
=; W Planning & Development Services Department
O Building & Code Regulation Division SC
o 2300 Virginia Avenue
Ft. Pierce, FL 34982-5652 S e Y
Tel.772-462-1553 t �uCis, coo
APPLICATION FOR ROOF PERMIT ty
SEE REVERSE SIDE FO INSTRUCTIONS
1. Location/Site Address: �� 'Qa�e 7i r+U� , �o�� P�c�cG. �C-_ 3g1571
2. Parcel ID Number: 131a - 801- 0030' UDO -!t
Office Use
Section
Townshi
Ran a
Ma Pa a
zoning
Land Use
I Initials
Only
3. Description of Project or Work Activity
4. Total Roof Area (square feet): Ll _"107 5. Roof Pitch: S 11 Q
6. Type of Roof: [ ✓rFiberglass Shingle [ ] Concrete Roof Tile
[ ] Tar & Gravel [ ] Modified Bitumen
[ ] Wood Shake / Shingle
[ ] Other
[ ] Product Approval required for all types of Roofing Material (2 Sets)
] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product
Approval attached
** Roof Mitigation per F.S. 553.844 will be required.
7. Owner Information 8. Contractor Information
Name: M0.r'I v✓, L F _ 40e ma-GIL
Address: /gbq r&glL-'N✓.
City:- R , R UCe. State: F-L
Zip: 3y9S l Phone: i7a -5141- HS8
9. Value of Construction: $ 31 p� . °O
FL Reg/Cert #: Ccr_ �Q
County Cert #:
Business Name: -772-,S61-088D
Cell Phone: 77a- y'13- G317
"Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval.
CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be
done in co ance with all applicable laws regulating construction and zoning.
RINT QUALIFIERS/OWNERS NAME GNATURE OF QUALIFIER/OWNER
STATE OF FLORIDA, COUNTY OF
ACKNOWLEDGED BEFORE ME THIS DAY OF r 1 C 20 BY. C
WHO IS PERSONALLY WN TO ME OR HAS PR UCED AS IDENTIFICATION
S GNAT R TA TYPE O RINT NAME OF NOTARY I (seal)
COMMISSION NUMBER
NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE
FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR R
LE
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. B fy�"MpNRV
" "' AwwwssloN# 116 20159
Revised4/26/2010 ,��0 y�c <_ Miy
O)a
Property Appraiser - St.Lucier r aunty, FL
- :� Page 1 of 1
PROPERTY RECORD CARD
Marjorie E Yormack Record: 1 of 1
<<Prev Next>> Spec.Assmnt
Taxes Exemptions Permits Home Print
Property Identification
;UCIE CO '
Site Address: 4804 Eagle Dr
ParcellD: 1312-801-0030-000-9
G
Sec/Town/Range: 13:34S :39E
Account* 4473
, z
Map ID: 13/13N '
Land Use: SF Res
Zoning: RS-4
City/Cnty: St Lucie County
Ownership and Mailing
Legal Description
Owner: Marjorie E Yormack
HOLIDAY PINES S/D-PHASE II-B- LOT 227 (MAP 13/13N) (OR 2096-
Address: 4804 Eagle Dr
1652)
Fort Pierce FL 34951-2348
Sales information
Assessment 2011 Final
Total Land and Building
Date Price Code Deed
Book/Page 2011 Final: 115100
Land Value: 19300 Acres: 0.32
11/4/2004 269900 00 WD
2096 / 1652 Assessed: 115100
Building Value: 96800
4/24/1989 24400 05 WD
0635 / 2085 Ag.Credit: 0
Finished Area: 1854 SgFt
5/1/1981 0 01 CV
0369 / 1031 Exempt: 50000
12/1/1980 19300 00 CV
0345 / 1206 Taxable: 65100
Taxes: 1521.46
BUILDING INFORMATION
Exterior Features
View: -
RoofCover:
SA - Asph Shingle
RoofStruct:
HP - Hip
ExtType: HC- - HC-
YearBit:
1994
Frame:
-
Grade: C- - C-
EffYrBit:
1994
PrimeWall:
BS - CB Stucco
StoryHght: 0010 -1 Story
No.Units:
1
SecWall:
-
Interior Features
BedRooms: 3
Electric:
MX - MAXIMUM
PrmintWall:
DW - Drywall
FullBath: 2
HeatType:
FHA - FrcdHotAir
AvgHt/FI:
STD
1/2Bath: 0
HeatFuel:
ELEC - Electric
Prm.Flors:
CU - Carpet
%A/C: 100
%Heated:
100
%Sprinkled:
0
Special Features and Yard Items
Land Information
Type Y/S Qty.
Units Qual. Cond.
YrBlt.
No. Land Use
Type
Measure Depth
ENC2 - POOL ENC-AVG Y
1
792
AV AV
1994
1 0100-SF Res
255 -Front Ft
101 135.87
SWAV - RES POOL AVG Y
1
420
AV AV
1994
PA01 - POOL DK-AVG Y
1
372
AV AV
1994
3CFT- 3CFT S
1
1
AV AV
1994
3CFT- 3CFT S
1
1
AV AV
1994
SDSF - SITE DEV S-F Y
1
1
AV AV
2001
THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED
http://www.pasle.org/paslc/prc.asp?prclid=l31280100300009 6/5/2012
JOSEPH E. SMITH, CLERK-oF THE CIRCUIT COURT - SAINT LUCIE COL _
FILE # 3710851 OR B04, '396 PAGE 1602, Recorded 06/05/2012 D2:19 PM
NOTICE OF COMMENCEMENT
TO BE COMPLETED WHEN CONSTRUCTION VALUE EXCEEDS $2,500.00
OR WHEN HEATING OR AIR CONDITIONING REPAIR OR REPLACEMENT EXCEEDS $7,500.00
PERMIT #: TAX FOLIO #: 1312-801-0030-000-9
Stale of Florida, County of St Lucie, the undersigned hereby gives notice that Improvement will be made to certain real property, and In
accordance with chapter 713, Florida statutes, the following information Is provided in this notice of Commencement,
1. LEGAL DESCRIPTION OF PROPERTY (AND STREET ADDRESS IF AVAILABLE):
4804 Eaale Or Fort Plerce Florida 34951-2348 Holiday Plnes S/D-Phase II-B- Lot 227 (Map 13/13N1(or 2096-
1652)
2. GENERAL DESCRIPTION OF IMPROVEMENT: Complete roof covering replacement
3. []OWNER INFORMATION or []LESSEE INFORMATION (If Lessee contracted for the Improvement)
a. Name Marione E. Yonnack
Address: 4804 Eaale Dr Fort Pierce, Florida 34951-2348
b. Interest in property: Owner
c. Name and address of fee simple title holder (if other than owner):
4. CONTRACTOR:
a. Name: Dependable Roofina Systems, Inc.
Address: PO Box 650721, Vero Beach, FL 32965
b. Phone number: (7721569-0880
5. SURETY COMPANY (IF Applicable, a copy of the payment bond is attached):
a. Name & Address:
b. Phone number: Bond amount:
6. LENDER/MORTGAGE COMPANY:
a. Name & Address:
b. Phone number.
7. PERSONS WITHIN THE STATE OF FLORIDA DESIGNATED BY OWNER UPON WHOM NOTICES OR OTHER DOCUMENTS MAY BE
SERVED AS PROVIDED BY SECTION 713.13 (1) (a) 7., FLORIDA STATUTES:
a. Name & Address:
b. Phone number, fax number:
B. IN ADDITION TO HIMSELF OR HERSELF,
a. Owner designates of to receive
a copy of the lienor's notice as provided in section 713.13(1) (b), Florida statues.
b. Phone number.
9. EXPIRATION DATE OF NOTICE OF COMMENCEMENT:
(THE EXPIRATION DATE IS ONE (1) YEAR FROM THE DATE OF RECORDING UNLESS A DIFFERENT DATE IS SPECIFIED).
WARNING TOOWNER:
ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713.
PART I, SECTION 713.13, FLORIDA STATUTES AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT
MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
UNDER PENALTIES OF PERJURY, I DECLARE THAT I HAVE READ THE FOREGOING AND THAT THE FACTS IN IT ARE TRUE TO THE BEST OF MY
KNOWLEDGE AND BELIEF (SECTION 92.525, FLORIDA STATUTES
�G.l�IDh.tJ✓ G . �Ls�2 rriuG�J
SIGNATURE16F OWNER or LRISIE or OWNER'S AUTHORIZED OFFICER/DIRECTOR/PARTNER/MANAGER
V Owner
SIGNATORY'S TITLE/OFFICE
THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME THIS �DAY OF 20L BY:
MA R%d e
AS Owner FOR Self
NAME OF PERSON TYPE OF AUTHORITY NAME OF PARTY ON BEHALF OF WHOM INSTRUMENT WAS EXECUTED
❑PERSONALLY KNOWN OR30PRODUCEDIDENTIFICATION TYPE OFIDENTIFICATION PRODUCED LTTR/tla)P_4 L/drNd/.SL—
.� Jo C . Le lv 2/ ��.. ;- , JW c.181a
. t IJYCOHLIISSION10DIp1110
OT SIG NOTARY PRINTED NAME NOTARY SEAL �*F
EXPIRES: Juao 5, 2Dt3
STATE 0 FLORIDA
ST• LUCIE COU'NTY
THIS IS TO CERTIFYTHATTHIS IS
TRUE A40.CORRECT COPY OFTµE ` �` F cT
ORIQFP�AE �
OS H E SMITH, CLERK
r
By. m
Deputy lerk ''
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34982
772-462-2165 or 772-462-2172
Fax: 772-462-6443
ROOF INSPECTION AFFIDAVIT
Re: Permit # 1-,7 O = L/Wq
I, C4-a'(/L' licensed as a(n)Contractor*/Engineer/Architect
( lease print name & circle license type) *F$468 Building Inspector
'General, Building, Residential or Roofing Contractor or any individual certified under 468 F.S. to make such an inspection.
On or about 6 I I l2 Ft— , I did personally inspect the roof deck nailing
(Date)
work at: 011 r r,5,t4 P;el-6E.,.>
/e'l (Job site address)
Based upon that examination I have determined the installation was done according to the Hurricane
Mitigation Retrofit Manual (Based on 553.844 F.S.)
it/Ot�
Signature and Seal
STATE OF FLORIDA
COUNTYOF �✓�� "iC-jr
License #
Sworn to and subscribed before me this 11 day of 131, N1C 20J-
by_F-0-1 VL Z,! CO�'0'Who is ep rsotilly known to me orwho has produced
as identification."' RECEIVED
Notary Public, State of Florl JUN 1 2012
Signature of Notary: V~—..
Commission Number: (Seal)
En 01/19/2011
tian�au:J-:, ^BETTYL.OU ROBERTS
MY COMMIMON # DD849864
EXPIRES Januarys 07, 2013
d0i)99U-07-i5 FWISduWp�grySdrvito.aom
TO/TO 30Vd ONId00d 3-19VGN3d3G 899066ZZLL ZT:VT ZTaZ/TT/90
Florida Building Code Online
r +
Page 1 of 2
it
C S ff .'IS S't Ma Links Search
3 i*^ € %!�)anrmw lAntl BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts , Publications — to e p
usines
rpY�'` �=P
Product Approval
Professi I II USER: Public User
Regulation
Prod iyE Approv_ai Menu > Product or AnolicaCipn Search > A�Itcaiiion l;is; > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who
developed the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
FL10674-R6
Revision
2010
Approved
e'0PV
j FILE
["2;`0PY
Owens Corning
One Owens Corning Parkway
Toledo, OH 43659
(740)404-7829
greg.keeler@owenscorning.com
Greg Keeler
greg.keeler@owenscorning.com
Mel Sancrant
1 Owens Corning PKWY
Toledo, OH 43659
(419)376-8360
mel.sancrant@owenscornig.com
Roofing
Asphalt Shingles
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
(_ Evaluation Report - Hardcopy Received
Robert J.M. Nleminen
PE-59166
Underwriters Laboratories Inc.
09/26/2014
John W. Knezevich, PE
Validation Checklist - Hardcopy Received
FL10674 R6 COI Trinity ERq CI - Nieminen.odf
Standard Year
ASTM D3161, Class F 2006
ASTM D3462 2007
ASTM D7158, Class H 2O07
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5 V%2b... 6/5/2012
Florida Building Code Online
Page 2 of 2
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
mary of Products
Method 1 Option D
02/16/2012
02/21/2012
02/24/2012
04/03/2012
FL #
Model, Number or Name IlDescription
10674.1
Owens Corning Asphalt Roofing
3-tab, laminated, starter, and hip & ridge
Shingles and Starters
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Installation Instructions
FL10674 R6 II er020612FINAL OC FL10674-
R6 Asphalt Shingles,odf
Verified By: Robert J. M. Nieminen PE - 59166
Created by Independent Third Party: Yes
Other: Refer to ER, Section 5.
Evaluation Reports
FL10674 R6 AE er02061.2FINAL OC FL10674-
R6 Asphalt Shingles.p,df
-
Created by Independent Third Party: Yes
Next
Contact Us :: 1940 North Monroe Street, Tallahassee FL 32M Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Copyright 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, e-mail addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not
send electronic mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions regarding DBPR's ADA web
accessibility, please contact our Web Master at webmaster(-)dbor.state.fl.us.
Product Approval Accepts:
is WN 0 go
securk
'LS'4�:ty;�sS'?y' V6k(Si�ii
http://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5 V%2b... 6/5/2012
RD
EVALUATION REPORT
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
Owens Corning Evaluation Report 037940.02.12
One Owens Corning Parkway FL10674-R6
Toledo, OH 43659 Date of Issuance: 02/06/2012
SCOPE:
This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing
the use of construction materials in the State of Florida. The documentation submitted has been
reviewed by Robert Nieminen, P.E. for use of the product under the. Florida Building Code and
Florida Building Code, Residential Volume. The products described herein have been designed to
comply with the 2010 FBC and 2010 FBC Residential Volume sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality
Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)
changes, the referenced Quality Assurance documentation changes, or provisions of the Code that
relate to the product change. Acceptance of this Evaluation Report by the named client constitutes
agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality
Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation
Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may
be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it
shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by
the manufacturer or its distributors and shall be available for inspection at the job site at the
request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized
by Robert Nieminen, P.E. on 02/06/2012
This does not serve as an electronically signed
document. Signed, sealed hardcopies have been
transmitted to the Product Approval Administrator and
to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does,not have, nor does It intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. TrinitylERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which
the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
TRINITYIERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have
demonstrated compliance with the following sections of the Florida Building Code and Florida Building
Code, Residential Volume through testing in accordance with the following Standards. Compliance is
subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard
Year
1507.2.5, R905.2.4 Physical Properties ASTM D3462
2007
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161, Class F
2006
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158, Class H
2O07
3. REFERENCES:
Entity Examination Reference
Date
UL (CER1739) Physicals & Wind Resistance File R2453, Vol. 3
02/15/2007
UL (TST1740) Physical Properties 06CA20263
04/18/2006
Miami -Dade (CER1592) FBC HVHZ Compliance 07-1116.12
02/14/2008
Miami -Dade (CER1592) FBC HVHZ Compliance 09-0915.12
12/16/2009
Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.09
10/27/2010
Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.10
10/27/2010
Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.08
10/27/2010
Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.07
10/27/2010
Miami -Dade (CER1592) FBC HVHZ Compliance 11-0411.03
06/16/2011
Miami -Dade (CER1592) FBC HVHZ Compliance 11-0919.05
10/13/2011
UL (QUA1743) Quality Control Service Confirmation
Exp. 09/26/2014
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic° and Supreme° are fiberglass reinforced, 3-tab asphalt roof shingles.
4.1.2 Berkshire° are fiberglass reinforced, 4-tab asphalt roof shingles.
4.1.3 Duration®, Duration° Premium, Oakridgeo and WeatherGuard° HP are fiberglass reinforced,
laminated asphalt roof shingles.
4.2 BerkshireO Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant and WeatherGuard° HP
Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles.
4.3 Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
S. LIMITATIONS:
5.1 This Evaluation Report is not for use in the HVHZ.
5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing
Materials Directory for fire ratings of this product.
5.3 Wind Classification:
5.3.1 / All Owens Corning shingles noted herein are Classified in accordance with FBC Tables
1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating
the shingles are acceptable for us in all wind zones up. to Vasd = 150 mph (V,it = 194 mph).
Refer to Section 6 for installation requirements to meet this wind rating.
Exterior Research and Design, LLC. Evaluation Report 037940.02.12
Certificate of Authorization #9503 FL10674-116
Date of Issuance: 02/06/2012
Page 2 of 6
s
IN ITY ERD
5.3.2 All Owens Corning hip & ridge shingles and Starter Strip Plus noted herein are Classified in
accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the
shingles are acceptable for us in all wind zones up to Vasa = 150 mph (V„it = 194 mph). Refer
to Section 6 for installation requirements to meet this wind rating.
5.3.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60
feet or less. Calculations by a qualified design professional are required for conditions outside
these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.3.4 Refer to Owens Corning published information on wind resistance and installationlimitations.
5.4 All products in the roof assembly shall have quality assurance audit in accordance with the
Florida Building Code and F.A.C. Rule 9N-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide
Product Approval, or be Locally Approved per Rule 9N-3, per FBC Sections 1507.2.3, 1507.2.4
or R905.2.3.
6.2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published
instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2
or R905.2, with the following exceptions:
➢ Berkshire° shingles require minimum five (5) nails per shingle.
➢ WeatherGuard° HP shingles require minimum six (6) nails per shingle.
➢ Starter Strip Plus requires minimum five (5) nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less
than FBC 1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of
fastening are required. Contact the shingle manufacturer for details.
6.2.5 Minimum Nailing — Classic@ & Supreme:
Normal Mamootd.or Area par;
Wind Areas H%h'�M ad dosvones y
Area pars vfontos normates- Areas viontoa f;artes
(A) t 2• B? t
L �!
V Exposaro
Expasleidn
Exterior Research and Design, LLC.
Certificate of Authorization #9503
Norman Mansard or Area pain
Wind Areas High VOW dosysnes y
Area, para vlentos normeles Areas vfentoe fuertes
1• 2' IBA 2`
21 t'�G �121
r. wi ' Exposure
Exposlaldn
Evaluation Report 037940.02.12
FL10674-R6
Date of Issuance: 02/06/2012
Page 3 of 6
6.2.6 Minimum Nailing - Berkshire@:
6.2.7 NV
6.2.8 1
Sealanfstrip.
la2iradeselladoY.
&Yt' 9Yf ' 9•v}' BYi'�' }
i Nailing - Duration@ & Duration@ Premium:
4 Nall-Pattem
Esquema de 4 davov,
. ;Swe•eaail°tastenlogaleawidth` .. __... _..
de elawsSureNaila
9 f rl¢ 4f
6Ye Exposure Nails W Exposure
6Yptrlg.de,exppskt4n 'Gairor. 6H,ptilg.c?eexpbs(ol6n.
linimum Nailing - Oakridge@:
4Nail Patfem
Es4ueMa'P9it 4-elavos
7r 1e;
'I-*— ir' =y►1
H� tz =1►1 `
5 fits" Exposure
Nails S 5/8 Exposure
Erpcslcfgri4sb5/Bpu14•,.
CfaYos Exposta4irtda55/Bpufg.•
("•-'"
ITR
IT . , ER
_SureflaL''a.'-SNeYbiP
:tasisnln�
3113W�A
tastmin99•
8leawitllA
AreadB
_ �
�P.' �.
-
\1
Neida
S aNSJ+^'
. �_ `12` ^i► \ �
^ n2'
�suuHaiP
5ib'.' Exposure,. 'Nails
5^hpufg. do erposlel4u Claws
SW Exposure
5% ping. de exppstet4n
S'NaIIPztCera`
Esguema;op 6;cl�vos'
Nall$.
5:518" Exposuree Gasps 6: big" Ezposu�a,
Ezposl8f6p ile 66/8 pufg. Expos(clbn de 65/8 ping.
Exterior Research and Design, LLC. Evaluation Report 037940.02.12
Certificate of Authorization #9503 FL10674-R6
Date of Issuance: 02/06/2012
Page 4 of 6
6.2.9 Minimum Nailing - WeatherGuard@ HP:
is"Btil. sift %%w
yr kftl ►•
r�lwe7�rdr'Nil u.
C�wYYlre i };d(Ir
6.3 Hip & Ridge Shingles:
6.3.1 Installation of Berkshire° Hip and Ridge Shingles, High Ridge, Hip & Ridge with Sealant and
WeatherGuard® HP Hip and Ridge Shingles shall comply with the manufacturer's current
published instructions, using four (4) nails per shingle. Refer to Owens Corning published
information on wind resistance and installation limitations, including the use of hand -sealing for
wind warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less
than FBC 1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing - Berkshire@ Hip & Ridge and High Ridge:
Fig. 1 4
t— Preva!lingWind• \\\
OirediohA \...
Nails A'
yQ
Exposure
6.3.4 Minimum Nailing - Hip & Ridge with Sealant:
itteirn Fig. 2 - fthi,W W Fastelning Pattern:
i 9014)
rim ° Shingle
ncl :Discalrc!' ;2 .:2,r;
6c ,ire�r
SS#ri
P 12"
' Fas#enngS°Exposure
D�s�noe
Exterior Research and Design, LLC. Evaluation Report 037940.02.12
Certificate of Authorization #9503 FL10674-R6
Date of Issuance: 02/06/2012
Page 5 of 6
6.3.5 Minimum Nailing — WeatherGuard® HP Hip and Ridge:
Fg..A fN q 4
Preuailing WInC
-- Dlredlon A Nails' 'T"?
1
p I' I
R I I
I I P I
I' I
\ A I I I
5 —
' 'Expgsuro
7. LABELING:
Fig. C Hip:& Ridge Shingle fastening
TopView'
Nails Nall$
7
2" 2"
I. t"
61
'Exposure
1: 12'
7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo
of the Accredited Quality Assurance Agency noted herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications
detailed in FBC Table 1507.2.7.1 / R905.2.6.1.
S. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the
installation of this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule
9N-3 QA requirements.
10. QUALITY ASSURANCE ENTITY:
Underwriters Laboratories — QUA1743; (414) 248-6409; karen.buchmann@ul.com
- END OF EVALUATION REPORT. -
Exterior Research and Design, LLC. Evaluation Report 037940.02.12
Certificate of Authorization #9503 FL10674-116
Date of Issuance: 02/06/2012
Page 6 of 6
Florida Building Code Online
Page 1 of 2
25i 4.°Et... �� g y�� .,f ,4trXa d►er
li
•! 9 y§ tD 9 4j'S
a..,o,.....zu"5'.f'..rytts.._..._.._,__cF.6 fr-a`w�wf...«,>, ,,.'f .. ♦..' rt
C'; ;iiGd DeptlneriitL'' BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search
Busines
�������� Product Approval
P (1i"111 - —�,( USER: Public User
Regulation
Produc A proyai Menu > Product or Applic4tlon Search > Appligation Ust > Application Detail
FL #
Application Type
_�¢
����,"
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who
developed the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
FL5259-R14
Revision
2010
Approved
POLYGLASS USA
150 Lyon Drive
Fernley, NV 89408
(570)384-1230 Ext242
jakins@polyglass.com
James Akins
jakins@polyglass.com
Steve Wadding
150 Lyon Drive
Fernley, NV 98408
(602)363-7139
stevew@polyglass.com
James Akins
555 Oakridge Road
Humboldt Industrial Pkwy
Hazleton, PA 18201
(800) 894-4563
jakins@polyglass.com
Roofing
Underlayments
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
r Evaluation Report - Hardcopy Received
Robert Nieminen
PE-59166
Underwriters Laboratories Inc.
11/30/2012
John W. Knezevich, PE
2 Validation Checklist - Hardcopy Received
FL5259 R14 COI Trinity ERD CI - Nieminen.odf
Standard
Year
ASTM D1970
2001
ASTM D226
2006
ASTM D6164
2005
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvbSgAaZp3 Crk2... 6/5/2012
Florida Building Code Online Page 2 of 2
ASTM D6222 2002
ASTM G154 2005
ASTM G155 2005
FM 4474 2004
FRSA/TRI07320 2005
TAS 103 1995
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
12/09/2011
Date Validated
12/15/2011
Date Pending FBC Approval
12/20/2011
Date Approved
01/31/2012
Date Revised
04/23/2012
...............
_....__.__.._.._.--...._...
CSummary of Products
FL #
Model, Number or
D escription
Name
5259.1
Polyglass Roof
Roofing underlayments
Underlayments
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL5259 R14 II er120611FINAL POLYGLASS UNDERLAYMENTS FL5259-
R14.Ddf
Approved for use outside
HVHZ: Yes
Verified By: Robert Nieminen PE-59166
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-622.5
Evaluation Reports
Other: 1.) The design pressure in this
FL5259 R14 AE er120611FINAL POLYGLASS UNDERLAYMENTS FL5259-
R14. d
application relates to one particular
underlayment system for use under
Created by Independent Third Party: Yes
foam -on tile systems. Refer to ER
Section 5.5.2 for other systems and
maximum design pressures. 2.) Refer
to ER Section 5 for other limits of use.
Back Next
Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: SSO-487-1824
The State of Florida is an AA/EEO employer. copyright 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, e-mail addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not
send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions regarding DBPR's.ADA web
accessibility, please contact our Web Master at webmaster(aidbor.state.Fl.us.
Product Approval Accepts:
"] ® sChzS.: El
�s,VNLrfcw\ St'GUtZt i'CjitC:°S°
•pc��z!�� nY' yar'i52ye1
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvbSgAaZp3 Crk2... 6/5/2012
'�T�,��RINITYJERD
EVALUATION REPORT
Polyglass USA, Inc.
150 Lyon Drive
Fernley, NV 98408
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
Evaluation Report P12060.02.09-R9
FL5259-R14
Date of Issuance: 02/24/2009
Revision 9: 12/06/2011
SCOPE:
This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing
the use of construction materials in the State of Florida. The documentation submitted has been
reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and
Florida Building Code, Residential Volume. The products described herein have been designed to
comply with the 2010 Florida Building Code sections noted herein.
DESCRIPTION: Polyglass Roof Underlayments
LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality
Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)
changes, the referenced Quality Assurance documentation changes, or provisions of the Code that
relate to the product change. Acceptance of this Evaluation Report by the named client constitutes
agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality
Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation
Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may
be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it
shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by
the manufacturer or its distributors and shall be available for inspection at the job site at the
request of the Building Official.
This Evaluation Report consists of pages 1 through 10.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized
by Robert Nleminen, P.E. on 12/06/2011
This does not serve as an electronically signed
document. Signed, sealed hardcopies have been
transmitted to the Product Approval Administrator and
to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial Interest in any company manufacturing or
distributing products it evaluates.
2. TrinitylERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which
the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
iR.o� ;ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have
demonstrated compliance with the following sections of the Florida Building Code through testing in
accordance with the following Standards. Compliance is subject to the Installation Requirements and
Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.3, 1507.3.3, 1507.5.3, Physical Properties ASTM D226 2006
1507.7.3, 1507.8.3, 1507.9.3
1507.2.4, 1507.2.9.2, 1507.3.3, Physical Properties ASTM D1970 2001
1507.5.3
1507.11.2
Physical Properties
ASTM D6164
2005
1507.11.2
Physical Properties
ASTM D6222
2002
1504.6
Accelerated Aging
ASTM G154
2005
1504.6
Accelerated Aging
ASTM G155
2005
1504.3.1
Wind Uplift
FM 4474
2004
1507.3.3
Installation Practice
FRSA/TRI 07320
2005
1523.6.5.2.1 Physical Properties TAS 103 1995
3. REFERENCES:
Entity
Examination
Reference
Date
FM Approvals (TST 1867)
Wind Uplift
3004091
01/12/2000
PRI (TST 5878)
Physical Properties
PRI01111
04/08/2002
PRI (TST 5878)
Physical Properties
PUSA-005-02-01
01/31/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-01
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-02
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-03
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-018-02-01
07/14/2003
PRI (TST 5878)
Physical Properties
PUSA-028-02-01
07/13/2005
PRI (TST 5878)
Physical Properties
PUSA-033-02-01
01/12/2006
PRI (TST 5878)
Physical Properties
PUSA-035-02-01
09/29/2006
PRI (TST 5878)
Physical Properties
PUSA-055-02-02
12/10/2007
PRI (TST 5878)
Physical Properties
PUSA-061-02-02
01/28/2008
PRI (TST 5878)
Physical Properties
PUSA-076-02-01
02/22/2008
PRI (TST 5878)
Physical Properties
PUSA-083-02-01
04/14/2008
PRI (TST 5878)
Physical Properties
PUSA-088-02-01
07/29/2009
MTI (TST 2508)
Physical Properties
JX20H7A
04/01/2008
MTI (TST 2508)
Physical Properties
RX14E8A
O1/29/2009
ERD (TST 6049)
Physical Properties
11752.09.99-1
02/08/2000
ERD (TST 6049)
Wind Uplift
11776.06.02
01/16/2003
ERD (TST 6049)
Physical Properties
02200.07.03
07/14/2003
ERD (TST 6049)
Wind Uplift
P1740.01.07
01/04/2007
ERD (TST 6049)
Physical Properties
P5110.04.07-1
04/11/2007
ERD (TST 6049)
Wind Uplift
P9260.03.08
03/21/2008
ERD (TST 6049)
Physical Properties
P13450.08.09
08/13/2009
ERD (TST 6049)
Wind Uplift
P30540.11.09-R1
11/30/2009
ERD (TST 6049)
Physical Properties
P33360.06.10
06/25/2010
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-119
Certificate of Authorization #9503 FL5259-R14
Revision 9: 12/06/2011
Page 2 of 10
Entity
ERD (TST 6049)
ERD (TST 6049)
ICC-ES (EVL 2396)
Miami -Dade (CER 1592)
Polyglass USA
Polyglass USA
Polyglass USA
UL (QUA1743)
4. PRODUCT DESCRIPTION:
Examination
Physical Properties
Physical Properties
IBC Compliance
HVHZ Compliance
Manufacturing Affidavit
P/L Affidavit
Materials Affidavit
Quality Control
4.1 Mechanically Fastened Underlavments:
T I ITYIERD
Reference Date
P33370.03.11 03/02/2011
P33370.04.11 04/26/2011
ESR-1697 11/01/2009
NOA Current
Products Current 02/18/2009
Mule -Hide Cross Ltg 03/01/2008
Polystick SA Compound 08/18/2011
File No. R14571, Vol 1 Exp. 11/30/2012
4.1.1 ELASTOBASE is a fiberglass reinforced, SBS modified bitumen base sheet.
4.1.2 ELASTOBASE P is a polyester -reinforced, SBS modified bitumen base sheet.
4.2 Self -Adhering Underlavments:
4.2.1 POLYSTICK MTS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber
reinforced, surfaced with polyolefinic film surface; meets ASTM D1970 and TAS 103.
4.2.2 POLYSTICK IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass
fiber reinforced, with an aggregate surface; meets ASTM D1970.
4.2.3 POLYSTICKTU is a nominal 100-mil thick rubberized asphalt waterproofing membrane, glass fiber
reinforced, with a granular surface; meets ASTM D1970 and TAS 103.
4.2.4 POLYSTICK TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane, glass
fiber reinforced, with a polyester fabric surface; meets ASTM D1970 and TAS 103.
4.2.5 POLYSTICK TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-
fiber/polyester reinforced, with a granular surface; meets ASTM D1970 and TAS 103.
4.2.6 POLYFLEX SAP, PoLYFLEX SAP FR, MULE -HIDE SA-APP CAP SHEET AND MULE -HIDE SA-APP CAP SHEET (FR)
are a polyester reinforced, APP modified bitumen cap sheets.
4.2.7 DUAL PROTM is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membranes,
fiberglass reinforced, with a polyester fabric surface.
4.2.8 TILE PROTM is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membranes,
fiberglass reinforced, with a polyester fabric surface.
4.3 Mechanically Fastened and/or Bonded Underlavments:
4.3.1 ELASTOFLEx S6G AND ELASTOFLEx S6G FR are polyester reinforced, SBS modified bitumen cap
sheets.
4.3.2 POLYFLEx G AND POLYFLEx G FR are polyester reinforced, APP modified bitumen cap sheets.
5. LIMITATIONS:
5.1 This Evaluation Report is not for use in the HVHZ.
5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing
Materials Directory for fire ratings of this product.
5.3 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is
specifically referenced within FBC approval documents. If not listed, a request may be made
to the AHJ for approval based on this evaluation combined with supporting data for the
prepared roof covering.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-119
Certificate of Authorization #9503 F1_5259-R14
Revision 9: 12/06/2011
Page 3 of 10
5.4 Allowable roof covers aDDlied atop the underlavments are as follows:
Table 1: Roof Cover Options
Underlayment
Asphalt
Nail -On Tile
Foam -On
Metal
wood
Shakes &
Slate
Shingles
Tile
Shingles
Elastobase
Yes
Yes
No
Yes
Yes
Yes
Elastobase P
Yes
Yes
No
Yes
Yes
Yes
Polystick MTS
Yes
Yes
No
Yes
Yes
Yes
Polystick IR-Xe
Yes
No
No
No
Yes
Yes
Polystick TU
Yes
Yes
es
No
Yes
Yes
See
5.Polystick
TU P
Yes
Yes
es
No
Yes
Yes
See
5.Polystick
TU Plus
Yes
Yes
es
Yes
Yes
Yes
See
5.Dual
Pro
Yes
Yes
No
Yes
Yes
Yes
Tile Pro
Yes
Yes
es
Yes
Yes
Yes
See
5.Elastoflex
S6G or S6G FR
Yes
Yes
No
No
Yes
Yes
Polyflex G or G FR
Yes
Yes
es
No
Yes
Yes
See
5.Polyflex
SAP or SAP FR
Yes
Yes
es
No
Yes
Yes
See
5.Mule-Hide
SA-APP Cap Sheet
Yes
Yes
Yes
No
Yes
Yes
or SA-APP Cap Sheet (FR)
See 5.4.1
5.4.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives unless tensile
adhesion / long term aging data from an accredited testing laboratory is provided.
➢ Polyfoam PolyPro AH160: Polystick TU, Polystick TU P, Polystick TU Plus, Polyflex G,
Polyflex G FR, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -
Hide SA-APP Cap Sheet (FR) or Tile Pro.
➢ Dow TileBond: Polystick TU P, Polyflex SAP or Tile Pro
5.4.2 For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the
tile.
5.4.3 A 2-ply underlayment system, consisting of Polystick MTS followed by Polystick MTS, TU, TU P
or TU Plus, or Polyflex SAP is allowable for use under mechanically attached prepared roof
systems. This is not a requirement, but is allowable if a 2-ply underlayment system is
desired.
Exterior Research and Design, LLC. Evaluation Report 11312060.02.09-119
Certificate of Authorization #9503 FL5259-R14
Revision 9: 12/06/2011
Page 4 of 10
5.5 Allowable substrates are noted below:
5.5.1 Direct -Bond to Deck:
Polystick, Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP
Cap Sheet (FR) self -adhered to:
➢ New untreated plywood;
➢ ASTM D41 primed new untreated plywood;
➢ Existing plywood;
➢ ASTM D41 primed existing plywood;
➢ ASTM D41 primed OSB;
➢ Southern Yellow Pine;
➢ ASTM D41 primed Southern Yellow Pine;
➢ ASTM D41 primed structural concrete;
➢ Huber Engineered Woods "ZIP System" Panels (designed and installed to meet wind loads
for project).
Note: Polyglass does not require priming of new or existing plywood sheathing. New or
existing plywood sheathing should be cleaned of all dirt and debris prior to application of
Polystick membranes.
Elastoflex S6G or S6G FR in hot asphalt to:
➢ ASTM D41 primed structural concrete.
Polyflex G or G FR torch -applied to:
➢ ASTM D41 primed structural concrete.
5.5.2 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI 07320
does not address wind uplift resistance of all underlayment systems beneath foam -on tile
systems, where the underlayment forms part of the load -path. The following wind uplift
limitations apply to underlayment systems that are not addressed in FRSA/TRI 07320 and are
used in foam -on the applications. Maximum Design Pressure is the result of testing for wind
load resistance based on allowable wind loads. Refer to FBC 1609.1.5 for determination of
design wind pressures.
5.5.2.1 Maximum Design Pressure = -622.5 Psf.
Deck: Structural concrete to meet project requirements to satisfaction of AHJ.
Primer: ASTM D41
Underlayment: Polyflex G or G FR torch -applied.
5.5.2.2 Maximum Design Pressure = -315 psf.
Deck: Structural concrete to meet project requirements to satisfaction of AHJ.
Primer: ASTM D41
Underlayment: Polystick TU, Polystick TU P, Polystick TU Plus, Tile Pro, Polyflex SAP, PolyFlex
SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR).
5.5.2.3 Maximum Design Pressure = -135 psf.
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optional) ASTM D41
Joints: Min. 4-inch wide strips of Elastoflex SA-V over all plywood joints.
Underlayment: Polystick TU, Polystick TU P, Polystick TU Plus, Polyflex SAP, PolyFlex SAP FR,
Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR)
Exterior Research and Design, LLC. Evaluation Report 1312060.02.09-119
Certificate of Authorization #9503 FL5259-1114
Revision 9: 12/06/2011
Page 5 of 10
I
INITY f ERQ
5.5.2.4 Maximum Desian Pressure = -90 psf.
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optional) ASTM D41
Underlayment: Polystick TU, Polystick TU P, Polystick TU Plus, Polyflex SAP, PolyFlex SAP FR,
Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR)
5.5.2.5 All other direct -deck, adhered Polyglass underlayment systems beneath foam -on tile systems
carry a Maximum Design Pressure of -45 psf.
5.5.3 Bond -to -Insulation:
➢ Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR)
self -adhered to: ASTM C1289, Type II, Class 1 polyisocyanurate or Type V
polyisocyanurate-composite insulation; DensDeck DuraGuard; DensDeck Prime; or
SECUROCK Gypsum -Fiber Roof Board.
➢ Elastoflex S6G or S6G FR in hot asphalt to: DensDeck. Prime or SECUROCK Gypsum -Fiber
Roof Board.
➢ Polyflex G or G FR torch -applied to: ASTM D41 primed structural concrete; DensDeck
Prime or SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be
attached per minimum requirements of the prepared roof covering manufacturer's Product
Approval. For installations under foam -on the systems, insulation attachment shall be
designed by a qualified design professional and installed based on testing of the
insulation/underlayment system in accordance with FM 4470, Appendix K or TAS 114,
Appendix I
5.5.4 Bond to Mechanically Attached Base Layer:
➢ P.olystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR)
Dual Pro or Tile Pro self -adhered to: ASTM D226, Type I or II felt; Elastobase; Elastobase
P or Mule -Hide Nail Base.
➢ Elastoflex S6G or S6G FR in hot asphalt to: ASTM D226, Type I or II felt; Elastobase;
Elastobase P or Mule -Hide Nail Base.
➢ Polyflex G or G FR torch -applied to: Elastobase; Elastobase P or Mule -Hide Nail Base.
For installations under mechanically attached prepared roof coverings, base layer shall be
attached per minimum codified requirements. For installations under foam -on tile systems,
base layer shall be attached per minimum requirements of FRSA/TRI 07320/8-05 or RAS 120.
5.6 Exposure Limitations:
5.6.1 Elastobase, Elastobase P, shall. not be left exposed for longer than 30-days after installation.
5.6.2 Polystick IR-Xe, Dual Pro or Tile Pro shall not be left exposed for longer than 90-days after
installation.
5.6.3 Polystick MTS, TU, TU P or TU Plus shall not be left exposed for longer than 180-days after
installation.
5.6.4 Polyflex SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not
have an exposure limitation, unless the prepared roof covering is to be adhesive -set tile, in
which case the maximum exposure is 30 days.
5.6.5 Elastoflex S6G or S6G FR or Polyflex G or G FR does not have an exposure limitation, unless
the prepared roof covering is to be adhesive -set the (Polyflex G or G FR only), in which case
the maximum exposure is 180 days.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R9
Certificate of Authorization #9503 FL5259-1114
Revision 9: 12/06/2011
Page 6of10
I
TRIG 1 IRd
i
5.7 For tile roof installations governed by the FRSA/TRI 07320/8-05 Installation Manual, Fourth
Edition, use is limited to the following. Reference is made to the FRSA/TRI Technical Brief
titled "Florida High Wind Roof Tile Self -Adhered Underlayment Requirements as of
02/14/2011" for limitations for self -adhering underlayments used beneath the roof systems.
Table 2: Tile System Options per FRSA/TRI 07320/8-05
System
Underlay
Option
Section
Reference
Product(s)
3.02A
1
Batten
Modified Cap Sheet
Elastoflex S6G or Elastoflex S6G FR; Polyflex G or G FR
only
No. 30 /Modified Cap
Base Layer: Elastobase; Elastobase P
System One:
2
3.02B
Sheet
Top Layer: Elastoflex S6G or Elastoflex S6G FR; Polyflex G
Mechanically
or G FR
Fastened Tile,
4
3.02D
No. 30
Elastobase; Elastobase P
Unsealed or
Sealed
Self -Adhered
Polystick MTS; TU; TU P; TU Plus; Polyflex SAP or SAP FR;
Underlayment
5
3.02E
Underlayment
SA-APP Cap Sheet or SA-APP Cap Sheet (FR);
System
Dual
Dual Pro; Tile Pro
Base Layer: ASTM D226, Type II; Elastobase; Elastobase P;
No. 30 / Self -Adhered
Mule -Hide Nail Base
6
3.02E
Underlayment
Top Layer: Polystick MTS; TU; TU P; TU Plus; Polyflex SAP
or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap
Sheet (FR); Dual Pro; Tile Pro
3.02A
1
Batten
Modified Cap Sheet
Elastoflex S6G or Elastoflex S6G FR; Polyflex G or G FR
only
No. 30 / Modified Cap
Base Layer: Elastobase; Elastobase P
System Two:
2
3.026
Sheet
Top Layer: Elastoflex S6G or Elastoflex S6G FR; Polyflex G
Mechanically
or G FR
Fastened Tile,
Self -Adhered
Polystick TU; TU P; TU Plus; Polyflex SAP or SAP FR; Mule -
Sealed
4
3.02D
Underlayment
Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR); Dual
Underlayment
Pro; Tile Pro
System
Base Layer: ASTM D226, Type II; Elastobase; Elastobase P;
No. 30 / Self -Adhered
Mule -Hide Nail Base
5
3.02E
Underlayment
Top Layer: Polystick TU; TU P; TU Plus; Polyflex SAP or SAP
FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR)
Dual Pro; Tile Pro
1
3.02A
Modified Cap Sheet
Polyflex G or G FR
System Four
2
3.02B
No. 30 / Modified Cap
Base Layer: Elastobase; Elastobase P
Sheet
Top Layer: Polyflex G or G FR
Adhesive -Set
4
3.021D
Self -Adhered
Polystick TU; TU P; TU Plus; Polyflex SAP or SAP FR; Tile
Tile, Unsealed or
Underlayment
Pro; Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR)
Sealed
Base Layer: ASTM D226, Type II; Elastobase; Elastobase P;
Underlayment
No. 30 / Self -Adhered
Mule -Hide Nail Base
System
5
3.02E
Underlayment
Top Layer: Polystick TU; TU P; TU Plus; Polyflex SAP or SAP
FR; Tile Pro; Mule -Hide SA-APP Cap Sheet or SA-APP Cap
Sheet(FR)
1
3.02A
No. 30 / Modified Cap
Base Layer: ASTM D226, Type II; Elastobase; Elastobase P
Sheet
Top Layer: Polyflex G or G FR
System Four
3
3.02C
Self -Adhered
Polystick TU; TU P; TU Plus; Polyflex SAP or SAP FR; Tile
Adh
Adhesive -Set
Underlayment
Pro; Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR)
Base Layer: ASTM D226, Type II; Elastobase; Elastobase P;
Tile, Sealed
Underlayment
No. 30 / Self -Adhered
Mule -Hide Nail Base
System
4
3.02D
Underlayment
Top Layer: Polystick TU; TU P; TU Plus; Polyflex SAP or SAP
FR; Tile Pro; Mule -Hide SA-APP Cap Sheet or SA-APP Cap
Sheet (FR)
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1119
Certificate of Authorization #9503 FL5259-1114
Revision 9: 12/06/2011
Page 7of10
6. INSTALLATION:
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published
installation requirements subject to the Limitations set forth in Section 5 herein and the
specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the
substrate thoroughly to remove any dust and debris prior to application, and prime the
substrate (if applicable).
6.3 Elastobase. Elastobase P or Mule -Hide Nail Base:
6.3.1 Shall be installed in compliance with the codified requirements for ASTM D226, Type II
underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed.
6.3.2 For use in non -tile applications:
6.3.2.1 Reference is made to the current edition of the NRCA Steep -slope Roofing Manual and ARMA
recommendations for installing shingle underlayments and flashings
6.3.2.2 Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick,
Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), Dual Pro or
Tile Pro, self -adhered, Elastoflex S6G or S6G FR in hot asphalt or Polyflex G or G FR, torch
applied.
6.3.3 For use in tile applications, reference is made to Polyglass published installation instructions in
conjunction with FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2
herein.
6.4 Polystick MTS, IR-Xe, TU _TU P or TU Plus, Polvflex SAP or SAP FR. Mule -Hide SA-
APP Cap Sheet or SA-APP Cap Sheet (FR), Dual Pro or Tile Pro:
6.4.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment
in FBC Sections 1507 for the type of prepared roof covering to be installed.
6.4.2 For non -tile applications:
6.4.2.1 All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR
and Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) should be back -nailed in selvage
edge seam in accordance with Polyglass / Mule -Hide Back Nailing Guide. Nails shall be
corrosion resistant, 11 gauge ring -shank type with a minimum 1-inch diameter metal disk or
Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back -
nailed using the above noted fasteners and spacing, in area marked "nail area, area para
clavar" on the face of membrane. The head lap membrane is to cover the area being back -
nailed
6.4.2.2 All seal -lap seams (selvage laps) must be firmly rolled with a minimum 28 lb. hand roller to
ensure full contact and adhesion. For Dual Pro and Tile Pro, align the edge of the top sheet to
the end of the glue pattern (the sheet will overlap the fabric).
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-119
Certificate of Authorization #9503 FL5259-1114
Revision 9: 12/06/2011
Page 8 of 10
�R0 I ERD
i
View of Ovelap Seam of Dual Pro and Tile Pro
6.4.2.3 All over -fabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyglass
Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing
Cement, Polyglass PG500 MB Flashing Cement, Polystick TU Plus Tile Underlayment Flashing
Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry
Electrometric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade
mastic, applied in between the application of the lap.
6.4.2.4 Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as
crickets, exposed valleys, or exposed roof to wall details
6.4.2.5 Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55
Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement,
Polyglass PG500 MB Flashing Cement, Polystick TU Plus Tile Underlayment Flashing Cement,
Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry
Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade
mastic to the area in need of repair, followed by a minimum 6 x 6 inch patch of the Polystick
material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed,
shall be installed in a water shedding manner.
6.4.2.6 All Polystick membranes shall be installed to ensure full contact with approved substrates.
Polyglass requires a minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff
broom with approximately 40-lbs of load applied for the field membrane. Hand rollers are
acceptable for rolling of patches, laps (min. 28 lb roller) or small areas of the roof that are not
accessible to a large roller or broom.
6.4.3 For tile applications (not allowed for Polystick IR-Xe):
6.4.3.1 Reference is made to Section 6.4.2 herein in conjunction with FRSA/TRI 07320/8-05
Installation Manual, Fourth Edition, and Table 2 herein, using the instructions noted above as
a guideline.
6.4.3.2 For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the
tile.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-119
Certificate of Authorization #9503 FL5259-1114
Revision 9: 12/06/2011
Page 9of10
6.5 Elastoflex S6G or S6G FR:
6.5.1 Elastoflex S6G or S6G FR shall be installed in compliance with current Polyglass published
installation requirements. For use in nail -on tile applications, reference is made to FRSA/TRI
07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein.
6.5.2 Elastoflex S6G or S6G FR shall be fully asphalt -applied to the substrates noted in Section 5.5.
Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, and off set end -laps
minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete
mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge.
6.6 Polyflex G or G FR:
6.6.1 Polyflex G or G FR shall be installed in compliance with current Polyglass published installation
requirements. For use in tile applications, reference is made FRSA/TRI 07320/8-05
Installation Manual, Fourth Edition, and Table 2 herein.
6.6.2 Polyflex G or G FR shall be fully asphalt -applied to the substrates noted in Section 5.5. Side
laps shall be minimum 3-inch and end -laps minimum 6-inch wide, and off set end -laps
minimum 3 feet from course to course. Side and end laps shall be fully heat -welded and
inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge.
6.7 Tile Staging:
6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment. Refer to Polyglass published requirements for tile staging..
6.7.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRI 07320/8-
05 must be used on all roof slopes greater than 7:12. For roof slopes in excess of 61/4:12,
precautions should be taken, such as the use of battens, to prevent tile sliding during the
loading process.
6.7.3 For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the
tile.
6.7.4 The minimum cure time after installation of self -adhering membranes and before loading of
roofing tiles is forty-eight (48) hours.
7. LABELING:
Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the
Accredited Quality Assurance Agency noted herein.
S. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the
installation of this product.
9. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C. Rule 9N-3 QA
requirements
10. QUALITY ASSURANCE ENTITY:
Underwriters Laboratories - QUA1743; (314) 578-3406; k.chanceilor@us.ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-119
Certificate of Authorization #9503 FL5259-1114
Revision 9: 12/06/2011
Page 10 of 10