Loading...
HomeMy WebLinkAboutSUBMITTED PAPERS01A Permit #: 120 - / - Planning & Development Services Department ICOUNTYBuilding & Code Regulation Division 8G, 2300 Virginia Avenue Ft. Pierce, FL 34982-5652 Tel. 772462-1553 St t4oe APPLICATION FOR ROOF PERMIT CoU { SEE REVERSE SIDE FOR INSTRUCTIONS nlJ 1. Location/Site Address: /-/I F4 pi`PXCP, �L 3K.S77l 2. Parcel ID Number: 131 a - Soo - o oat - 06o/9 Office Use Only Section Township Range I Map Ppge I Zoning Land Use Initials .3q5 f / ��i `I L q 3. Description of Project or Work Activity: 4. Total Roof Area (square feet): �_d 5. Roof Pitch: /fz 6. Type of Roof Fiberglass Shingle [ ] Concrete Roof Tile [ ] Wood Shake / Shingle [ ] Tar & Gravel ( ] Modified Bitumen [ ] Other ` [ ] Product Approval required for all types of Roofing Material (2 Sets) 46)0 59�� [ ] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product Approval attached ** Roof Mitigation per F.S. 553.844 will be required. 7. Owner Information 8. Contractor Information Name: kmdi ai&�el aahez►s FL Reg/Cert #: e&,, U,S-PO a--/ Address: Ea-1, Pnd ZM . County Cert #: 0_05V City: �r State: Business Name: 9,'c!„e TAe Rooi'ei Zip: S S7 Phone: M?-" d8"0�0l� CellPhone: 9. Value of Construction: $ lay W "Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval. CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in compliance with all applicable laws regulating construction and zoning. PRINT QUALIFIERS/OWNERS NAME URE OF QUALIFIER/OWNER I STATE OF FLORIDA, COUNTY OF I _ Le'i e, ACKNOWLEDGED BEFORE ME THIS _ DAY OF jU,4-� 20 ZBY %C O IS PERSONAL Y KN ✓ TA E OR HAS PRODUCED AS II?y4NTIFICATION 4�It'�� AU,, Nancy L, Hamilton COMMISSION#EE035845 ISNAT F NOTARY TYPE OR PRINT NAME OF NOTARY (s � c 'o- r EXPIRES: OCT. 19, 2014 COMMISSION NUMBER rnEo3S84'�_ ,,;��°�, www,AARONNoTARY.com NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Revised 4/26/2010 I- j Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 772-462-2165 or 772-462-2172 Fax: 772-462-6443 ROOF INSPECTION AFFIDAVIT Re: Permit # 26r 60 I ) I, P'A. //eW/0-/7d licensed as d(n)Contractor*/Engineer/Architect (Please print name & circle license type) *FS468 Building Inspector *General, Building, Residential or Roofing Contractor or any individual certified under 468 F.S. to make such an inspection. On or about , I did personally inspect the roof deck nailing (Date) work at: hall / Z-/, FI-.101 e1P-C-e) FL -�WS/ (Job site address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S.) Signature and Seal License # STATE OF FLORIDA COUNTY OF c5�• L I.CG! Swo n-to and sub�c�.ibed�before � me this � � day ofiwtt 20 � by X e�{Oi r2L DVZ�%Gwu-rn Who is personally kn�to me or who has produced as identification. Notary Public, Stat Florida Signature of Nota .: __ Commission NumbeW EEd q'c (Seal) "lton T'Y"!" Nancy L. �Y PGM- OM.N SSI E 315845 En 01/19/2011 3�.'.'o e fit ww" WW. ?�� WAARONN TARYccom Permit No. State of Florida County of St. Lucie NOTICE OF COMMENCEMENT Tax Folio No. /3 / a 8LI9 0 - 00,P-9 - D0%j The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. of General description of improvement: address if Owner info ation r s ee 'nfor ation if the Lp� ee co tracted for the improvement: Name Address ` Interest in property: �f,Ui'I PAY Name and address of fee simple titleholder (if different from Owner listed above): Contractor's Name: Contractor Address: Surety (if applicable, a co,fp�y� f the payment bond is attached): Amount of bond: $ Name and address: /V� Phone number: Lender Name:/" Phone Number: Lender's address: Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section, 713.13(1) (a)7., Florida Statutes: Name: NIP,- Phone Number: Address: In addition to himself or herself, Owner designates Lienor's Notice as provided in Section 713.13(1) (b), Florida Statutes. Phone number of person or entity designated by owner: to receive a copy of the Expiration date of notice of commencement: (the expiration date may not be before the completion of construction and final payment to the contractor, but will be 1 year from the date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury, I declare that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of my knoyAeoge and belief. n _ (Signature of Owner or see, or Owner's iir Lessee's Authorized Officer/Director/Partner/Manager (Signatory's Title/Office) The foregoing Instrument was acknowledged before me this day o20 -/ �Ll By&;ai4aw&&s as to for sa4w Name of Person Type of authority (e.g. officer, trustee) Party on behalf of whom instrument was executed Personally known V or produced Identification Sign ur of Notary Public - State of Florida) (Prin T e, or Stamp Commissioned Name of Notary Public) Type of Identification produced !q,.yPq ,, Nancy L. Hamilton CAM!11SSION#EE035845 EXPIRES: OCT. 19,2014 ''h„0;, ,". WWW. AARON N OTARY.com rnUF>0 nQ M—(A a0a'r� 5 m� omn r O --q oc)gcz z r, --10 m O W J fJ 0 o m Property Appraiser - St.Lucie County, FL Page 1 of 1 PROPERTY RECORD CARD Ronald J Stephens Record: 1 of 1 <<Prev Next » Spec.Assmnt Taxes Exemptions Permits Home Print Property Identification Site Address: 5211 INDIAN BEND LN ParcellD: 1312-800-0028-000-9 ��VdI;IEC�G2 SecJTown/Range: 12 :34S :39E Account #: 4439 y� _ Map ID: 13/12S Zoning: RS-4 Land Use: SF Res City/Cnty: St Lucie County { 1 Ownership and Mailing Legal Description Owner: Ronald J Stephens Patricia A Stephens HOLIDAY PINES S/D-PHASE II -A- LOT 197 (MAP 13/12S) (OR 752- Address: 5211 Indian Bend Ln 2856) Fort Pierce FL 34951-2398 Sales Information Assessment 2011 Final Total Land and Building Date Price Code Deed Book/Page 2011 Final: 115600 Land Value: 19700 Acres: 0.39 8/28/1991 144000 00 WD 0752 / 2856 Assessed: 115600 Building Value: 95900 2/1/1986 24000 00 CV 0492 / 0455 Ag.Credit: 0 Finished Area: 1832 SgFt 4/1/1985 25000 00 CV 0460 / 1202 Exempt: 50000 8/1/1983 23000 00 CV 0409 / 2196 Taxable: 65600 10/1 /1980 22800 00 CV 0343 / 2476 Taxes: 1531.63 BUILDING INFORMATION Exterior Features View: - RoofCover: SA - Asph Shingle RoofStrud: HP - Hip ExtType: HC+ - HC+ YearBlt: 1987 Frame: - Grade: C+ - C+ EffYrBlt: 1987 PrimeWall: BS - CB Stucco StoryHght: 0010 -1 Story No.Units: 1 SecWall: - Interior Features BedRooms: 3 Electric: MX - MAXIMUM PrmintWall: DW - Drywall FullBath: 2 HeatType: FHA - FrcdHotAir AvgHtIFI: STD 1/213ath: 0 HeatFuel: ELEC - Electric Prm.Flors: CU - Carpet %A/C: 100 %Heated: 100 %Sprinkled: 0 Special Features and Yard Items Land Information Type Y/S Qty. Units Qual. Cond. YrBlt. No. Land Use Type Measure Depth SWAV - RES POOL AVG Y 1 300 AV AV 1987 1 0100-SF Res GFI -Front Ft 91 184.67 PA01 - POOL DK-AVG Y 1 492 AV AV 1987 ENC2 - POOL ENC-AVG Y 1 792 AV AV 1987 4CNT - 4CNT S 1 1 AV AV 1987 SDSF - SITE DEV S-F Y 1 1 AV AV 2001 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED. http://www.paslc.org/paslc/prc.asp?prclid=131280000280009 5/22/2012 REVISIONS BUILDING ROOF LAYOUT SCALE: N.TS. IlAr jAr jAr .A JQJ (9) 10101 0 L A r JA� ROOF ZONES SCALE: N.T.S. COMPONENT & CLADDING DESIGN PRESSURES: ROOF LOCATION ACTUAL ALLOWABLE ZONE 1 FIELD -27.8 PSF -90.0 PSF ZONE 2 PERIMETER -62.4 PSF -90.0 PSF ZONE 3 CORNERS -88.1 PSF -90.0 PSF WOOD DECKING: 19/32" (MIN.) PLYWOOD OR WOOD PLANKING @ 24" O.C. SPANS ATTACHED WITH 8d NAILS @ 6" O.C. MAX. IN THE FIELD & 6" O.C. MAX. AT THE PERIMETER. CALCULATIONS BASED ON THE ROOFING APP. STANDARD (RAS117) BONDED ROOF COVER: COVER PLYWOOD WITH SBS-SA BASE & CAP SHEET (BASED ON FLORIDA PRODUCT APPROVAL #FL6785-R4). ZONE 1: ALLOW. UPLIFT = -90.0 PSF > ACTUAL = .27.8 PSF ZONE 2: ALLOW. UPLIFT = -90.0 PSF > ACTUAL = -62.4 PSF ZONE 3: ALLOW. UPLIFT w -90.0 PSF > ACTUAL = -88.1 PSF USE SYSTEM NO. W 32 FROM THE "CARLISLE COATINGS & WATERPROOFING" PRODUCT APPROVAL #FL6785-R4 NOTES: 1. ROOFING OVER EXISTING WOOD DECK. 2. INSTALL FASTENERS PER REQUIRED FREQUENCY LISTED ABOVE FOR WOOD DECKING & ROOF COVER. 3. FOLLOW ALL LOCAL & REGIONAL ORDINANCES. 4. USE BONDING/FASTENERS AS PER REQUIRED MANUFACTURERS SPECIFICATIONS & FL#6785-R4. 5. ALL DIMENSIONS ARE TO BE VERIFIED BY CONTRACTOR. 9� PP, w M2 OM U��t� d"M wao � s 0 0m c POE zo 0°0 "� DESIGN CRITERIA:, • F 2010 FBC ASCE 7-10 3 WIND LOAD: 160 MPH WIND BORNE DEBRIS REGION MEAN ROOF HEIGHT:' < -16 DRAWN MAY 12 HIP/GABLE ROOF CONDITION.. RY JASON w. a . .R ENCLOSED BLDG. f1JDhTJ-asn BLDG CATEGORY II Jws EXPOSURE: "C" ADJUSTMENT FACTOR: 1.21 AS SHOWN GCPI: +/- 0.18 END ZONE (A): 5.6' SF= Sr1 Florida Building Code Online FLORIDA 011PARTMIENT OF Business & l Professional Regulation ^^�' r��rrr flodda Departn'te t BCIS Home I Log In I user Registration I Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links search Busines Professi �"dl Product Approval ■ USER: Public User Regulation Product Approval Menu > Product or ADolication Search > Aoolication Llst > Application Detail FL # FL6785-R4 Application Type Editorial Change Code Version 2010 Application Status Pending FBC Approval Comments Archived ❑ Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License` Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Page 1 of 2 Carlisle Coatings & Waterproofing 900 Hensley Lane Wylie, TX 75098 (717)245-7000 Ext7456 wert@syntec.carlisle.com Chad Wert wert@syntec.carlisle.com Roofing Underlayments Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Robert Nieminen PE-59166 UL LLC 02/20/2013 John W. Knezevich, PE ❑J Validation Checklist - Hardcopy Received FL6785 R4 COI Trinity ERD CI - Nieminen.pdf Standard ASTM D1970 Year 2001 h4://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvkdyKrmfaLgB... 5/22/2012 Florida Building Code Online Page 2 of 2 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Method 1 Option D 04/11/2012 04/25/2012 04/28/2012 Summary of Products FL # 1 Model, Number or Name Description 6785.1 JICCW Roof Underlayments Self -Adhesive Roofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ: No FL6785 R4 II er041912FINAL CARLISLE UNDERLAYMENTS FL6785- R4.odf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Nieminen 59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: 1.) Refer to ER Section 5 for Evaluation Reports of Use 2.) Refer to ER Section 6 for FL6785 R4 AE er041912FINAL CARLISLE UNDERLAYMENTS FL6785- R4.odf ,Limits Installation. Created by Independent Third Party: Yes Back Next Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, e-mail addresses are public records. If you do not want your a -mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions regarding DBPR's ADA web accessibility, please contact our Web Master at webmaster(aadbpr.state.fl.us. Product Approval Accepts: ® ® cin.. Norton. secant'"eca"' SECURED '� PoWurcd by VeriSigb http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvkdyKrmfaLgB... 5/22/2012 ,l TPJNITYIERD EVALUATION REPORT Carlisle Coatings & Waterproofing 900 Hensley Lane Wylie, TX 75098 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 Evaluation Report C39180.12.11-R1 FL6785-R4 Date of Issuance: 12/09/2011 Revision 1: 04/22/2012 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code- and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2010 Florida Building Code sections noted herein. DESCRIPTION: CCW Roof Underlayments LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement, to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinitylERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 4. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 04/22/2012 This does not serve as an electronically signed document. Signed, sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE.' 1. TrinityJERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. TrinitylERD is not awned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a .financial interest in any other entity involved in the approval process of the product. - ROOFING COMPONENT EVALUATION: TRINITY I ERD 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: CCW Roof Underlayments, as produced by Carlisle Coatings & Waterproofing, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.4, 1507.2.9.2, Physical Properties ASTM D1970 2001 1507.5.3 3. REFERENCES: Entity Examination Reference Date MTI (TST2SO8) Physical Properties PX02MOA 01/17/2011 MTI (TST2508) Physical Properties PXI6MOA 01/18/2011 MTI (TST2508) Physical Properties PXI3MOB 01/18/2011 M-D (CER1592) HVHZ Compliance 09-0630.13 08/12/2009 ICC-ES (EVL2396) 2006 IBC Compliance ESR-1556 08/01/2007 UL, LLC. (QUA9625) Quality Control Inspection Report, R18678 02/20/2012 4. PRODUCT DESCRIPTION: 4.1 CCW WIP 100 is a self -adhering, fiberglass reinforced, granule surfaced, rubberized asphalt roof underlayment. 4.2 CCW WIP 250 is a self -adhering, fiberglass reinforced, film surfaced, rubberized asphalt roof underlayment. S. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ. 5.2 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.3 CCW Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the AH] for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.4 Allowable roof covers applied atop the underlayments are follows: Table 1: Roof Cover Options Asphalt Foam -On Wood Slate & Underlayment Shingles Nail -On Tile Tile Metal Shakes & Synthetic Shingles Slate/Shake CCW WIP 100 Yes No No No No No CCW WIP 250 Yes No No Yes No No Exterior Research and Design, LLC. Evaluation Report C39180.12.11-R1 certificate of Authorization #9503 FL6785-R4 Revision 1: 04/19/2012 Page 2of4 ��TRINITYJERD 5.5 Allowable substrates are noted below: 5.5.1 Direct -Bond to Deck: Self -adhering membranes applied to: ➢ New untreated plywood; ➢ Primed new untreated plywood; ➢ Existing plywood; ➢ Primed existing plywood; Note: While not required, CCW-702 or CAV-GRIP primer may be used when deemed appropriate or when temperatures are below 40°F. 5.5.2 Bond to Mechanically Attached Base Layer: Self -adhering membranes applied to: ➢ ASTM D226, Type I or II felt; For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. 5.6 Exposure Limitations: 5.6.1 CCW WIP 100 and CCW WIP 250 shall not be left exposed for longer than 30-days after installation. 6. INSTALLATION: 6.1 CCW Roof Underlayments shall be installed in accordance with Carlisle Coatings & Waterproofing published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application. Prime the substrate (if applicable) with CCW-702 or CAV-GRIP Primer. 6.3 CCW WIP 100 and CCW WIP 250: 6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.3.2 While not required, CCW-702 or CAV-GRIP primer may be used when deemed appropriate. Priming is required when temperatures are below 40°F. 6.3.3 Cut WIP roofing underlayment into 10 to 15 ft lengths. Remove 2 to 3 ft of release film and align the edge of the membrane, sticky -side down, so it overhangs the drip edge by 3/8-inch. Continue to remove release film and press as you move across the roof. Use a hand roller and/or hand pressure to press into place. 6.3.4 Horizontal seams should be minimum 3.5-inches, configured to shed water. Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in the course below. 6.3.5 Consult Carlisle Coatings & Waterproofing for steep slope & back nailing requirements. 6.3.6 For Valleys and Ridges: Cut WIP 100 roofing underlayment into manageable lengths. Align over the center of the valley, hip or ridge. Remove release film. Press the middle of the membrane first before working toward the edges. For open valleys, cover roofing underlayment with metal valley liners. Exterior Research and Design, LLC. Evaluation Report C39180.12.11-R1 CertiFcate of Authorization #9503 FL678S-R4 Revision 1: 04/19/2012 Page 3 of 4 i Q�TRINJTYJERD 7. LABELING: Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. S. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the manufacturer or the named QA entity for plants covered under Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL, LLC- QUA9625; (847) 664-3281 - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report C39180.12.11-R1 certiFcate of Authorization #9503 FL6785-R4 Revision 1: 04/19/2012 Page 4 of 4 - EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 Christian Street TRINITY ERD Oxford, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT Polyglass USA, Inc. Evaluation Report P9290.02.08-118 150 Lyon Drive FL1654-R10 Fernley, NV 89408 Date of Issuance: 02/11/2008 Revision 8: 12/06/2011 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been designed to comply with the 2010 Florida Building Code sections noted herein. DESCRIPTION: Polyglass SBS and APP Modified Bitumen Roof Systems LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 5, plus a 30-page Appendix. Prepared by: 5�= The facsimile seal appearing was authorized -pp_ ;'4 by Robert Nieminen, P.E. on 12/06/2011 This does not serve as an electronically signed '�sbq tiC'r`.: •' document. Signed, sealed hardcopies have been Robert J.M. Nieminen, P.E. '��,s�ip��l�;��7 transmitted to the Product Approval Administrator and Florida Registration No. 59166, Florida DC ANEd983 4"""" to the named client pp CERTIFICATION OF INDEPENDENCE: 1. Exterior Research & Design, LLC. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Modified Bitumen Roof Systems Compliance Statement: Polyglass SBS and APP Modified Bitumen Roof Systems, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind FM 4474 2004 1504.7 Impact FM 4470 1992 1507.11.2 Physical Properties ASTM D6163 2000 1507.11.2 Physical Properties ASTM D6164 2005 1507.11.2 Physical Properties ASTM D6222 2002 3. REFERENCES: Entit Examination Reference Date ERD (TST6049) Physical Properties P10490.10.08-2 10/30/2008 ERD (TST6049) FM 4470/4474 P13760.09.09 09/10/2009 ERD (TST6049) FM 4470/4474 P13770.09.09 09/10/2009 ERD (TST6049) FM 4470/4474 P30540.11.09-R1 11/30/2009 ERD (TST6049) FM 4470/4474 P30550.12.09 12/02/2009 ERD (TST6049) Physical Properties P33960.12.10 12/30/2010 ERD (TST6049) FM 4470/4474 P33970 12/02/2009 FM Approvals (TST1867) FM 4470 2W7A7.AM 08/04/1994 FM Approvals (TST1867) FM 4470 OD3A3.AM 04/04/1997 FM Approvals (TST1867) FM 4470 2DOAO.AM 12/23/1998 FM Approvals (TST1867) FM 4470 2D5A9.AM 06/22/1999 FM Approvals (TST1867) FM 4470 3006646 01/04/2000 FM Approvals (TST1867) FM 4470 3001334 01/25/2000 FM Approvals (TST1867) FM 4470 3001334 02/15/2000 FM Approvals (TST1867) FM 4470 3000857 01/12/2000 FM Approvals (TST1867) FM 4470 3004091 01/12/2000 FM Approvals (TST1867) FM 4470 3006115 05/02/2001 FM Approvals (TST1867) FM 4470 3012321 07/29/2002 FM Approvals (TST1867) FM 4470 3014692 08/05/2003 FM Approvals (TST1867) FM 4470 3014751 08/27/2003 FM Approvals (TST1867) FM 4470 3007170 01/13/2004 FM Approvals (TST1867) FM 4470 3019317 06/30/2004 FM Approvals (TST1867) FM 4470 3020703 07/30/2004 FM Approvals (TST1867) FM 4470/4474 3018332 01/31/2006 FM Approvals (TST1867) FM 4470/4474 3023368 03/20/2006 FM Approvals (TST1867) FM 4470/4474 302,4594 05/23/2006 FM Approvals (TST1867) FM 4470/4474 3023458 07/18/2006 FM Approvals (TST1867) FM 4470/4474 3030668 09/12/2007 FM Approvals (TST1867) FM 4470/4474 3032172 06/12/2009 PRI (TST5878) Physical Properties PUSA-062-02-01 12/04/2007 PRI (TST5878) Physical Properties PUSA-061-02-02 01/28/2008 PRI (TST5878) Physical Properties PUSA-064-02-02 02/27/2008 PRI (TST5878) Physical Properties PUSA-062-02-02 12/04/2008 UL (QUA1734) Quality Control UL File R14571 Exp. 11/30/2012 Miami -Dade (CER1592) HVHZ Compliance Various NOAs Various Miami -Dade (CER1592) Proposal for Review 10-0823 10/12/2010 Exterior Research and Design, LLC. Evaluation Report P9290.02.08-R8 Certificate of Authorization #9503 FL1654-R10 Revision 8: 12/06/2011 Page 2of5 4. PRODUCT DESCRIPTION: This Evaluation Report covers Polyglass Modified Bitumen Roof Systems installed in accordance with Polyglass USA, Inc. published installation instructions and the Limitations / Conditions of Use herein. The following Polyglass membranes make up the subject systems. Table 1: Roll -Goods for Polyglass Modified Bitumen Roof Systems Type Product Specification Reference Grade Type Base Sheets Polyglass G2 Base ASTM D4601 N/A II Modibase ASTM D4601 N/A II SBS Membranes Elastobase ASTM D6163 S I Elastoflex V ASTM D6163 S I Elastoflex SA V Base ASTM D6163, Table 2 S I Elastoflex SA V FR Base ASTM D6163, Table 2 S I Elastoflex SA V Plus ASTM D6163 S I Elastoflex SA V Plus FR ASTM D6163 S I Elastoflex SA V Vent ASTM D6163 S I Elastoflex SA V Vent FR ASTM D6163 S I Elastobase Poly ASTM D6164 S I Elastoflex S6 ASTM D6164 S I Elastoflex S6 G ASTM D6164 G I Elastoflex S6 G FR ASTM D6164 G I Polyfresko MOP ASTM D6164 S I Polyfresko MOP FR ASTM D6164 S I Elastoshield TS G ASTM D6164 S I Elastoshield TS G FR ASTM D6164 G I Elastoflex SA P ASTM D6164 G I Elastoflex SA P FR ASTM D6164 G I Polyfresko SBS SAP ASTM D6164 S I Polyfresko SBS SAP FR ASTM D6164 S I APP Membranes Polyflex ASTM D6222 S I Polyflex G ASTM D6222 G I Polyflex G FR ASTM D6222 G I Polyfresko Torch ASTM D6222 S I Polyfresko Torch FR ASTM D6222 S I Polybond ASTM D6222 S I Polybond G ASTM D6222 G I Polyflex SA P ASTM D6222 G I Polyflex SA P FR ASTM D6222 G I Polyfresko APP SAP ASTM D6222 S I Polyfresko APP SAP FR ASTM D6222 S I Polykool ASTM D6222 S I Polybianko ASTM D6222 S I Exterior Research and Design, LLC. Evaluation Report P9290.02.08-118 Certificate of Authorization #9503 FL1654-RIO Revision 8: 12/06/2011 Page 3 of 5 �..TRINITY I I ERD 5. LIMITATIONS: 5.1 This Evaluation Report is not for use in HVHZ. 5.2 Refer to a current Roofing Materials Directory for fire ratings of this product. 5.3 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply. 5.4 Unless otherwise noted in Appendix 1, roof decking and its attachment shall be specified and installed to meet project design criteria to the satisfaction of the AHJ. 5.5 For recover installations, the existing roof shall be examined in accordance with FBC 1510. 5.6 For mechanically attached insulation or membrane or strip -bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117 and FM LPDS 1-29. 'Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3 enhancements. 5.7 For fully -adhered insulation, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems 5.8 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI FX-1. 5.9 For bonded insulation or membrane over existing substrates in a re -roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ASTM E907, FM LPDS 1-52, ANSI/SPRI IA-1 or TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.10 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the AHJ, as documented through field uplift testing in accordance with ASTM E907, FM LPDS 1-52 or TAS 124. 5.11 Metal edge attachment (exept gutters), shall be designed and installed for wind loads in accordance with FBC Chapter 16 and tested for for resistance in accordance with ANSI/SPRI ES-1 or RAS 111, except the basic wind speed shall be determined from FBC Figure 1609. 5.12 All products in the roof assembly shall have quality assurance audit in accordance with the FBC and F.A.C. Rule 9N-3. 6. INSTALLATION: 6.1 Polyglass Modified Bitumen roof systems shall be installed in accordance with Polyglass USA,. Inc. published installation instructions, subject to the Limitations / Conditions of Use noted below. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. Ekterior Research and Design, LLC. Evaluation Report P9290.02.08-118 Certificate of Authorization ##9503 FL1654-RIO Revision 8: 12/06/2011 Page 4of5 t'RINITY I ERR 6.3 Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind load performance. Refer to current Roofing Materials Directory for fire ratings associated with coating usage. ➢ PG200 Non Fibered Roof Coating or Mule -Hide 111 Non-Fibrated Roof Coating; ➢ PG300 Fibered Roof Coating or Mule -Hide 102 Fibrated Roof Coating; ➢ PG600 Non-Fibered Aluminum Roof Coating or Mule -Hide 416 Standard Non-Fibrated Aluminum Roof Coating; ➢ PG650 Fibered Aluminum Roof Coating or Mule -Hide 406 Standard Fibrated Aluminum Roof Coating; ➢ PG700 White Reflective Roof Coating; ➢ PG800 Non-Fibered Asphalt Emulsion Roof Coating or Mule -Hide 311 Emulsion Non-Fibrated; ➢ PG850 Fibered Asphalt Emulsion Roof Coating or Mule -Hide 301 Emulsion Fibrated; ➢ Polyplus 60 Premium Non-Fibered Aluminum Roof Coating or Mule -Hide 410 Premium Non-Fibrated Aluminum Roof Coating; ➢ Polyplus 65 Premium Fibered Aluminum Roof Coating or Mule -Hide 401 Premium Fibrated Aluminum Roof Coating; ➢ Polybrite 70 White Elastomeric Roof Coating. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. Rule 9N-3 QA requirements 9. QUALITY ASSURANCE ENTITY: Underwriters Laboratories - QUA1743; (314) 578-3406, k.chancellor@us.ul.com - THE 30-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report 139290.02.08-118 Certificate of Authorization #9503 ' • FL1654-R10 Revision 8: 12/06/2011 Page 5 of 5 ',j TRIM Y { ER® TABLE IE: WOOD DECKS - NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Base Sheet Roof Cover MDP (psf) Base Fasteners Attach Ply Cap No. Roof Deck Min. 19/32-inch plywood at 32 ga., 1-5/8-inch diameter 6-Inch o.c. In 4-inch lap and Inch in four, (Optional) One or more SBS-AA, SBS- 112.5 W-30 max. 24-inch spans attached Elastobase or Elastobase Poly tin caps with 11 ga. annular spaced, equally spaced, 11 A, SB SBS-AA, SBS-TA TA, APP-TA 6-Inch o.c. with #8 screws ring shank nails staggered center rows or APP-TA (Optional) One or Min. 19/32-Inch plywood at Elastobase or Elastobase Poly with poly 32 ga., 1-5/8-inch diameterSBS- tin caps with 11 ga. annular In 4-Inch lap 6-inch and 6-inch o.c. In four, and more Ilex SA (no E/astofiex SA V SBS-SA, APP- 112.5 W-31 max. 24-Inch spans attached top surface ring shank Halls. Note: Tin equally spaced, Base or ElastoFlex SA, SBS-TA or AP; -TA 6-Inch o.c. with #8 screws caps are to be primed with staggered center rows SA Base), PG100 orASTM D41 primer. -FR SBS-TA or APP-TA TABLE 1F: WOOD DECKS - NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE F: NON -INSULATED, BONDED ROOF COVER System N..N Deck Primer; Roof Cover MDP_-(Psf)-� ]oint Treatment Base x24-inch spans attached 6 r SS - (Optional) 565 SA, SB5=5A; APP SA _ 90 0 W-32 I a.¢, with 8d rf­g shank gg�� (Opaonaf) PG100 - - — -SBS TA APP-TA (Optional) SBS SA, to or APP-T!C SBS-SA, APP-SA, -97 5 MI 15/32-inch plywood at Plywood joints are covered with 4-Inch ElastoFlex SA V W-33 ma . 24-inch spans attached 6- (Optional) PG100 wide strips of ElastoFlex SA V Plus, rolled Base or ElastoFlex SBS-TA or APP-TA S85-TA or APP-TA in o.c. with #12 screws into place to create continuous bond. SA V FR Base . 15/32-Inch plywood at Plywood joints are covered with 4-inch ElastoFlex SA V Plus (Optional) SBS SA, SBS SA, APP-SA, _ mi x. 24-Inch spans attached 6- (Optional) PG100 wide strips of ElastoFlex SA V Plus, rolled I or ElastoFlex SA V SBS-TA or APP-TA SBS-TA or APP-TA135.0 o.c. with #12 screws Into place to create continuous bond. Plus FR Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report P9290.02.08-R8 for FL1654-R30 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 9 of 30 l� Florida Building Code Onlit O Page 1 of 2 Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo, OH 43659 (740)404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo, OH 43659 (419)376-8360 mel.sancrant@owenscornig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who Robert J.M. Nieminen developed the Evaluation Report Florida License PE-59166 Quality Assurance Entity Underwriters Laboratories Inc. Quality Assurance Contract Expiration Date 09/26/2014 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL10674 R6 COI Trinity ERD CI Nieminen.odf Referenced Standard and Year (of Standard) Standard Year ASTM D3161, Class F 2006 ASTM D3462 2007 ASTM D7158, Class H 2O07 Equivalence of Product Standards Certified By http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5 V%2b... 6/5/2012 Florida Building Code Onlii ) Page 2 of 2 Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Iry of Products Method 1 Option D 02/16/2012 02/21/2012 02/24/2012 04/03/2012 FL # Model, Number or Name IlDescriDtion 10674.1 Owens Corning Asphalt Roofing 3-tab, laminated, starter, and hip & ridge Shingles and Starters Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Installation Instructions FL10674 R6 II er020612FINAL OC FL10674- R6 Asphalt Shingles.pdf Impact Resistant: N/A Verified By: Robert 1. M. Nieminen PE - 59166 Design Pressure: N/A Other: Refer to ER, Section 5. Created by Independent Third Party: Yes Evaluation Reports FLI 74 R6 AE er02061.2FINAL OC FL10674- R6_ Asphalt Shinclles.pdf Created by Independent Third Party: Yes Stack Pdext Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, e-mail addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions regarding DBPR's ADA web accessibility, please contact our Web Master at webmasterOdbor.state.Fl.us. Product Approval Accepts: rz ���� i 5CY.'ldCit55ti SSi14::�° i 3 sre ':p yxexl9igf� http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5 V%2b... 6/5/2012 F EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 I 353 CHRISTIAN STREET, UNIT #13 ' , T 1 ERR OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12 One Owens Corning Parkway FL10674-116 Toledo, OH 43659 Date of Issuance: 02/06/2012 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein -have been designed to comply with the 2010 FBC and 2010 FBC Residential Volume sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 02/06/2012 This does not serve as an electronically signed document. Signed, sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION or- INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity] ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. (TTRINITYIERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2007 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161, Class F 2006 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158, Class H 2O07 3. REFERENCES: Entity Examination Reference Date UL (CER1739) Physicals & Wind Resistance File R2453, Vol. 3 02/15/2007 UL (TST1740) Physical Properties 06CA20263 04/18/2006 Miami -Dade (CER1592) FBC HVHZ Compliance 07-1116.12 02/14/2008 Miami -Dade (CER1592) FBC HVHZ Compliance 09-0915.12 12/16/2009 Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.09 10/27/2010 Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.10 10/27/2010 Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.08 10/27/2010 Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.07 10/27/2010 Miami -Dade (CER1592) FBC HVHZ Compliance 11-0411.03 06/16/2011 Miami -Dade (CER1592) FBC HVHZ Compliance 11-0919.05 10/13/2011 UL (QUA1743) Quality Control Service Confirmation Exp. 09/26/2014 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic® and Supreme® are fiberglass reinforced, 3-tab asphalt roof shingles. 4.1.2 Berkshire° are fiberglass reinforced, 4-tab asphalt roof shingles. 4.1.3 Duration®, Duration° Premium, Oakridge° and WeatherGuard° HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Berkshire® Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant and WeatherGuard° HP Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.3 Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ. 5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.3 Wind Classification: 5.3.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for us in all wind zones up to Vasd = 150 mph (V,it = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. Exterior Research and Design, LLC. Evaluation Report 037940.02.12 Certificate of Authorization #9503 FL10674-1116 Date of Issuance: 02/06/2012 Page 2 of 6 6.2.6 Minimum Nailing - Berkshire@: V1�s Seatamstrip !a bra de sdtador 84 8 ya' 911f a+/f 8 ys" 1' t 1 2" Asphalt rooting oement Cemaeto de texho de aataho 6.2.7 Minimum Nailing - Duration@ & Duration@ Premium: 4 Nail Pattern Esquoma de 4 claws SureNaitslpsteningata'r V*11h Areade dawsSureNaita t' t' IV Exposure rags Erb"Exposure S%Patg.deexposlddn Clavos 6%pu1g.dedxpos1c16n 6.2.8 Minimum Nailing - Oakridge@: 4 Nail Pattern Esquema con 4 claws 1r I•E -- +z —sl It— �r. —+•I — t — 5618"Exposure Nails 66/S"Exposure Exposidande66/81u# CIAvS Exposiddndo66/6ptdg. (a"raetdaMSWPS6Nel nunlam 4 anaacPrnMILPattern Esquema b xa 8� ax dwd s do 6 daws • • aw Herat rnh u �casanarasay�ie � a�rSradaG�lreale. ', SUrtNa $aAiW "'1ftlfufM �` 1d9M�9 ergrW115 avaai o ` LE Ir � sa�Fj a' �r S%" Exposure Naffs 5W Exposure 666pu1g.dearposictdo Clavos 691palq,dooxposida7 6 Nail Pattern Esquema con 6 claws r I 6 6/8" Exposure Claws 6 6/8" Exposu e Fxpostddn de 65/BPrdg. Exposiddn & G&T putg. Exterior Research and Design, LLC. Evaluation Report 037940.02.12 Certificate of Authorization #9503 F1.10674-116 Date of Issuance: 02/06/2012 Page 4 of 6 6.3.5 Minimum Nailing — WeatherGuard@ HP Hip and Ridge: Fig. A � 4 Prevalling Wnp 4 Olrecibn ... A A\ Nails "_""--------->44 i t I 1 1 7. LABELING: Fig. C Hip & Ridge Shingle Fastening TopVbvi Nails Nails VT _I 1 51 , Exposure 12 7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. S. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: Underwriters Laboratories — QUA1743; (414) 248-6409; karen.buchmann(cbul.com END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report 037940.02.12 Certificate of Authorization #9503 FL10674-116 Date of Issuance: 02/06/2012 Page 6 of 6 5.3.2 All Owens Corning hip & ridge shingles and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for us in all wind zones up to V,,d = 150 mph (V,,,t = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.3.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.3.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.4 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 9N-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 9N-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: ➢ Berkshire° shingles require minimum five (5) nails per shingle. ➢ WeatherGuard° HP shingles require minimum six (6) nails per shingle. ➢ Starter Strip Plus requires minimum five (5) nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. 6.2.5 Minimum Nailing - Classic® & Supreme: Normal Mansard or Area paro Wind Areas High Wind dosvanos y Aron pars viontos normalos Ames viontos luertes 5"Exposuro ExposicMa Exterior Research and Design, LLC. Certificate of Authorization #9503 Normal Monsord or Ara& pars Wind Areas High Wind dosvanoa y Aron porn viontos normalos Aroas viontos firertos r r •L__._ 8 W8 Exposure Exposicl6n Evaluation Report 037940.02.12 FL10674-R6 Date of Issuance: 02/06/2012 1 Page 3 of 6 6.2.9 Minimum Nailing - WeatherGuard® HP: Ciw�r IeY°ri lwaib 6.3 Hip & Ridge Shingles: 6.3.1 Installation of Berkshire° Hip and Ridge Shingles, High Ridge, Hip & Ridge with Sealant and WeatherGuard° HP Hip and Ridge Shingles shall comply with the manufacturer's current published instructions, using four (4) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand -sealing for wind warranties. 6.3.2 C-193 6.3.4 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. Minimum Nailing - Berkshire® Hip & Ridge and High Ridge: Fig.1 4 Direction VNnU \�A� Nails fe, i A � l i i 1 1 i 1 i v v w r Exposure Minimum Nailing - Hip & Ridge with Sealant: tternn Fig. 2 -High WM Fastening ftttem 14 Flails) rriYii�n ryShingrk- - �• and DCS t`Ci y°N 9 �ii GeSs .lop l9! Ex --� Sealant �-•--r/ R Strip I . "1 12" „ Fastening S Vtk? S Er ExRosti e Distance � 12 Exterior Research and Design, LLC. Certificate of Authorization #9503 Fig. 2 TepYieRl sidemev Nails Nails 10 2' Tap Lan6latal I(1 !I{" piece i � '—•......._. ..... ..._.�s..._............... 1 J 1 1 II" et I J) z1 cY t 1 l t I Evaluation Report 037940.02.12 FL10674-R6 Date of Issuance: 02/06/2012 Page 5 of 6