HomeMy WebLinkAboutSUBMITTED PAPERSDate: /J' ,i Fee Due:V t> I ReceiD -;�j Permit #
Planning & Development Services SC��NE®
Building & Code Regulations
lagionsnia Division St. Luv. cie Cpunty
Fort Pierce, FL 34982
(772)462-1553
SPECIALTY PERMIT APPLICATION
❑ Electrical ❑ Plumbing RVAC ❑Fence
❑ Shed ❑ Demolition ❑ Gas ❑ Siding
Seepage 2 for instructions and additional paperwork required for specialty permits
1. Location/Site Address:
2. Parcel ID Number: 4-009— 001a -00 �- 5✓
Office Use
Only
Section
199
Township
Range
Map Page
Zoning
Land Use
Initials
(,S
2�
VYl
3. Complete Description of Project or Work: L YA C+ AC c lltn e _ or—
A. se-LI72 �5- 79)a Mc9l . t'
4. Owners
Name:
Address:
City: W1
Zip:
6. Value of Construction: s, 1P (0 .
PA FI
ontractors Information
FL Reg/Cert #: 0 - ' . �� 16 q
'71 F-7.
County Cert#: p�Gj
Business Name: 41 "'Or Ce
�' Phone:'RfttW y(6gYFax:
OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in
compliance with all applicable laws regul ting construction and zoning.
® 1 Q5 A an I
PRINT OWNER OR CONTRACTOR N SIGNATURE OF OWNER OR CONTRACTO
STATE OF FLORIDA, COUNTY OF
ACKNOWLED THIS �2 DAY OF 20—n BY
Commission # DD 961665
WHO IS RSONALLY KNO E OR WHO HAS PRODUCED , *?15� 2014
%t= 800 5 7019
e�Th�7royFainlnsuMAW
AS IDENTIFICA ION,
(seal)
SIG A URE OF NOTARY
COMMISSION NUMBER
TYPE OR PRINT NAME OF NOTARY
NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR
LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
EXEMPT: A/C -HEAT REPLACEMENT WITH CONTRACT UNDER $7500.00
Revised 04/26/2010
06/ 05/ 2012 18: 35 9546E•-- " 30 ALL YEAR 0001-10'"-') PAGE 01 / 02
" righ Project Summary Job:
Entire House Data:
ALL YEAR COOLING AND HEATING By:
1245 NE 4TH AVE. PORT 1Ji: @;I )ALE, FL 33304 Phone: 054 556 4644 FOX 954 840 0200 Wrb; ALLMROOOLINOANpHEATINOMM
uii�mmn
Proiect I'tforftatii-ai-f
For: Sovereign Bank/Belknap
118 Ocean Bay Dr, St Lucie County, FL
"'I� tes:
�� III��III � '
• r _ •
•
Weather:
Fort Lauderdale/Hollywood, FL, US
W i1xiiii Design Conditions
Summer Design Conditions
Outside db 50 OF
Inside db 70 OF
Outside db
Inside db
90 OF
of
Design TO 20 T
Design TD
�5
15 °F
Daily range
L
Relative humidity
50
Moisture difference
61 gr/lb
Hint, ting Summary
Structure
97076
Stub
Ducts
9663
Stub
Central vent ( cfrri
0
Stuh
Humidificatiol
0
Btuh
Piping
0
Stull
Equipment for 1
106739
Stub
nfiltratKion
Method
Simplified
Construction, ,r,litj
Average
Fireplaces
0
Heating
Cooling
Area (ft�
3274
3274
Volume ("
26197.
26192
Air changes/h jr
0.28
0.15
Equiv. AVF (c ,I).
122
65
Heal n.[.1i , ?quipment Summary
Make
Trade
Model
AHRI ref no. r i
Efficiency
Heating Input
Heating outpu
Temperature i ,a
Actual air flow
Air flow factor
Static pressur
Space therma Iill•
100 EFF
0 Btuh
106739 Btuh
51 "F
1917 cfm
0,018 cfm/Btuh
0 in H2O
Sensible Cooling Equipment Load Sizing
Structure 34249 Stub
Ducts 16807 Stub
Central vent (0 cfm) 0 Stub
Blower 0 Htuh
Use manufacturer's data n
Rate/swing multiplier 0.95
Equipment sensible load 48504 Btuh
Latent Cooling Equipment Load Sizing
Structure
$$$$
Stub
Ducts
4784
Stub
Central vent (0 cfm)
0
Stuh
Equipment latent load
s320
Stub
Equipment total load
56823
Btuh
Req, total capacity at 0.70 SHR
5.8
ton
Cooling Equipment Summary
Make Trane
Trade XR15
Cond 4TTR5061 E1
Coil *AM7A0C60H51
AHRI ref no. 4385368
Efficlency
13.0 EER, 18 SEER
Sensible cooling
40250
Btuh
Latent cooling
17250
Btuh
Total cooling
57500
Btuh
Actual airflow
1917
cfm
Air flow factor
0.038
cfm/Btuh
Static pressure
0
in H2O
Load sensible heat ratio
0.86
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
x�l I�I'iaPl t* 2012�May-31 M07;07
RIAht-8ult®®Unlveraa12072 12.0.07 RSU12433 mutt ilroddavo lenlr,Ir, win—smlth.rup calc - MJa Fronl Door Mana; N Page I
This combination qualifies for a Federal Energy
Efficiency Tax Credit when placed in service
between Feb 17, 2009 and Dec 31, 2011.
Certificate of Product Ratings
AHRI Certified Reference Number: 4385368 Date: 5/17/2012
Product: Split System: Air -Cooled Condensing Unit, Coil with Blower
Outdoor Unit Model Number: 4TTR5061 E1
Indoor Unit Model Number: *AM7A0C60H51
Manufacturer: TRANE
Trade/Brand name: XR15
Manufacturer responsible for the rating of this system combination is TRANE
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air -Conditioning and Air -Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third
party testing:
Cooling Capacity (Btuh):
57500
* Ratings followed by an asterisk (*) indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate.
DISCLAIMER
AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for,
the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the
unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectoryorg.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes.
The contents of this Certificate may not, In whole or In part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any
form or manner or by any means, except for the user's Individual, personal and confidential reference.
CERTIFICATE VERIFICATION
The Information for the model cited on this certificate can be verified at www.ahridirectoryorg, Air -Conditioning, Heating,
click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on On ,' and Refrigeration Institute
which the certificate was issued, which is listed above, and the Certificate No., which is listed below.
02012 Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129817420323152433
Property Appraiser - St.Lucie 1'^unty, FL
Page 1 of 1
\
PROPERTY RECORD CARD
Brian B Belknap Record: 1 of 1 <<Prev Next» Spec.Assmnt
Taxes Exemptions Permits Home Print
Property Identification
CIE
Site Address: 118 Ocean Bay Dr
ParcellD: 3522-608-0012-000-5 �G,L
Sec/Town/Range: 22:36S:41 E
Account* 168782
y
Map ID: 35/22S
Land Use: Condo
Zoning: HIRD
City/Cnty: St Lucie County
'
Ownership and Mailing
Legal Description
Owner: Brian B Belknap Andrea B Belknap
OCEAN BAY VILLAS (OR
2627-1946) UNIT 118 (OR 3391-1687)
Address: 118 Ocean Bay Dr
Jensen Beach FL 34957
Sales Information
Assessment 2011 Final
Total Land and Building
Date Price Code Deed
Book/Page 2011 Final: 264900
Land Value: 0 Acres: 0.02
5/2/2012 280000 0112 SP
3391 11687 Assessed: 264900
Building Value: 264900
3/29/2012 100 0112 CT
3376 / 1022 Ag.Credit: 0
Finished Area: 2374 SgFt
2/14/2007 826700 00 SP
2763 / 2065 Exempt:
6/25/2004 10000000 02 SP
2000 / 2701 Taxable:
Taxes: 5389.58
BUILDING INFORMATION
Exterior Features
0030
View: - RoofCover: -
30%
ExtType: X233 - OceanBayVila YearBlt: 2007
Grade: 233E - OcnBayVila-B EffYrBit: 2007
StoryHght: 0030 - 3 Story No.Units: 1
Interior Features
RoofStruct: -
Frame:
PrimeWall: BS - CB Stucco
SecWall: -
BedRooms: 4 Electric: - PrmintWall: -
FullBath: 0 HeatType: - AvgHt/FI:
1/2Bath: 0 HeatFuel: - Prm.Flors: -
%A/C: 0 %Heated: 0 %Sprinkled: 0
Special Features and Yard Items Land information
Type Y/S Qty. Units Qual. Cond. YrBlt. No. Land Use Type Measure Depth
1 0400-Condo N -Unit 1
THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED.
126 � OV