HomeMy WebLinkAboutSUBMITTED PAPERSDATE: (p / FEES DUERECEIPT #: Permit #:
-3
Planning & Development Services Department
Building & Code Regulation Division SCqNN
a 2300 Virginia Avenue �®
Ft. Pierce, FL 34982-5652 St Lb
Tel. 772462-1553
APPLICATION FOR ROOF PERMIT cr�®u�tY
SEE REVERSE SIDE FOR INSTRUCTIONS
1. Location/Site Address: 8003 KEN�VOOO ROAb
2. Parcel IDNumber: /30/ -,005 -D.236- Do0 -5
Office Use
Section
Township
Range
Map Page
I Zoning
Land Use
Initials
Only
-S
�✓'�
��
3. Description of Projector Work Activity:-)' E-yOVE FC/ST/nlG S')4 i/VGLE 6CovF 1-ZVSTLIIJ— A1t-1-
4. Total Roof Area (square feet): o?, SOO S. y'. 5. Roof Pitch: 31a-Z / �;L
6. Type of Roof: M Fiberglass Shingle [ ] Concrete Roof Tile [ ] Wood Shake / Shingle
[ ] Tar & Gravel [ ] Modified Bitumen [ ] Other
[X] Product Approval required for all types of Roofimg Material (2 Sets)
] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product
Approval attached
** Roof Mitigation per F.S. 553.844 will be required.
7. Owner Information 8. Contractor Information
Name: (Jn+� i cL l . Xros k J
Address: So 0 3 9e h wocxl 2oA d
City: For4lYerct, State: PL
FL Reg/Cert #: e & D 5110,q.3 9
County Cert #: 0'/5
Business Name: Vig I.,ql« RoOrIA16,L 1P�p,A1 �S
Zip: ,3'Y 5/-2V 18 Phone: 77.� - 116I - 6.3 CellPhone:
9. Value of Construction: $ 8r.300 —
43 -6341- /5 2,7
"Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval.
CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be
done in compliance with all applicable laws regulating construction and zoning.
PRINT QUALIFIERS/OWNERS NAME SIGNATUAE OF Q IFIER/OWNER
STATE OF FLORIDA, COUNTY OF 57- LU —1E
ACKNOWLEDGED BEFORE METHIS _DAY OF JUPIE 201,?— ,BY,/QS"FPM P- �J(Ek Jam -
WHO IS PERSONALLY KNOWN _yTO ME OR HAS PRODUCED AS IDENTIFICATION
SIGNAT NOTARY TYPE OR PRINT NAME OF NOTARY `�!"Y-"%eal) VIKKI i_YNN AARON
;ro•
My COMMISSION # DD904290
COMMISSION NUMBER a� %o5/29a = EXPIRES July 01, 2013
OF Fti
Notar Servwce.com
NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEME s'''—ESULi-Y8 CE
FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
Revised 4/26/2010
Property Appraiser - St.Lucie County, FL
hitp://www.paslc.org/paslc/prc.asp?prclid=130160502300005
i
PROPERTY RECORD CARD
Cynthia L Krosky
Record: I of 1 <<Prev Next» Spec.Assmnt Taxes Exemptions Permits Home Print
Property Identification
Site Address:
8003 KENWOOD RD
ParcellD:
1301-605-0230-000-5
y y<
Sec/Town/Range:
O2:34S:39E
Account*
1258
Map ID:
13/02S
Land Use:
SF Res
Zoning:
RS-4
City/Cnty:
St Lucie County
Ownership and:Mailing '
Legal Description
Owner:
Cynthia L Krosky Brooklynn H Pohl
LAKEWOOD PARK -UNIT 5- BLK 48 LOT30 (MAP 13102S) (OR 578-1947:
Address:
8003 Kenwood Rd
1643-2228; 2989-1851)
Fort Pierce FL 34951-2418
Sales Information
Assessment 2011 Final Total Land and Building
Date
Price Code Deed
Book/Page
2011 Final: 54100 Land Value: 5100 Acres: 0.24
6/27/2008
100 01 QC
2989 / 1851
Assessed: 54100 Building Value: 49000
8/252002
100 01 QC
1643 / 2228
Ag.Credit: 0 Finished Area: 1410 SgFt
3/1/1988
100 01 CV
0578 / 1947
Exempt: 29100
12/1 /1980
61000 00 CV
0345 / 1074
Taxable: 25000
7/1/1979
55000 00 CV
0313 / 1796
Taxes: 540.94
BUILDING INFORMATION
Exterior Features
View:
-
RoofCover:
FS - Fibrglss Shg
RoofStruct:
GA- Gable
ExtType:
HD+ - HD+
YearBlt:
1975
Frame:
-
Grade:
D+ - D+
EftYrBlt:
1975
PrimeWall:
BS - CB Stucco
StoryHght:
0010 -1 Story
No.Units:
1
SecWall:
-
Interior Features
BedRooms:
3
Electric:
MX- MAXIMUM
PrmintWall:
DW - Drywall
FullBath:
2
HeatType:
FHA -FrcdHotAir
AvgHUFI:
STD
1/2Bath:
0
HeatFuel:
ELEC - Electric
Prm.Flors:
CU - Carpet
%A/C:
100
%Heated:
100
%Sprinkled:
0
Special Features and Yard
Items
Land Information
Type
Y/S Qty.
Units Qual. Cond. YrBlt,
No. Land Use
Type
Measure Depth
FNW6 - WOOD FEN 6'
Y 1
180 AV AV 1988
1 0100-SF Res
BI -Front Ft
80 131
DWC - Driv-Concret Y 1 520 AV AV 1975
THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED
1 of 1 6/5/2012 2:02 PM
JOSEPH E. SMITH, CLERK OF THE CIRCUIT COURT - SAINT,LUCIE COUNTY
FILE # 3712346 OR(-�,DK 3398 PAGE 764, Recorded C 18/2012 at 10:33 1
NOTICE OF COMMENCEMENT
Permit No. Tax Folio No. 1301-605-0230-000-5
State of Florida County of St. Lucie
The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter713, Florida Statutes,
the following information is provided in this Notice of Commencement
Legal Description of Property: (and street address if available):
8003 Kenwood Road Lakewood Park — Unit 5 — Block 48 — Lot 30
General description of improvement: Re —roof
Owner Information or Lessee information If the Lessee contracted for the improvement:
Name , Cynthia L. Krocky
Address 8003 Kenwppd Road Fort Pierce FL 34951-2418
Interest In property: owner
Name and address of fee simple titleholder (if different from Owner listed above):
Not applicable
Contractor's Name: Big Lake Roofing & Repairs
Contractor Address: 2699 NW 16 Blvd Okeechobee, FL 34972 Phone Number:863-763-7663
Surety (if applicable, a copy of the payment bond is attached): Amount of bond: $
Name and address: not applicable Phone number:
Lender Name: not applicable Phone Number:
Lender's address:
Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section
713.13(1) (a)7., Florida Statutes:
Name: Phone Number:
Address:
In addition to himself or herself, Owner designates
Uenor's Notice as provided in Section 713.13(1) (b), Florida Statutes.
Phone number of person or entity designated by owner:
to receive a copy of the
Expiration date of notice of commencement: (the expiration date may not be before the completion of construction and final payment to the
contractor, but will be 1 year from the date of recording unless a different date Is specified)
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED
IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR
RECORDING YOUR NOTICE OF COMMENCEMENT.
Under penalty of perjury, I declare that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of
my kn ledge a d belief.
n
(Si Lure of owner or Lessee, or Owne or Lessee's Authorized Officer/Director/Partner/Manager
owner
(Signatory's Title/Office)
aA
The fforegoing instrument was acknowledged before me this 8 — day of JUNE , ZB /Z,
By eynfhla_ 1. J'r05 R as OlW17er for l ynfhia L. Xrosky
Name of Person Type of authority (e.g. officer, trustee) Party on behalf of whom instrument was executed
Personally known k or produced Identification_
(Signature of Nota ublic-State of Florida) VIKKI LYNN AARON
(Print, Type, or Stamp Commissioned Name ol t:#. rgvoy COMMISSION N DD90429T
of Identification produced
syIl
^+�oF-ho,�.�' EXPIRES July 01, 2013
(407)398-53 FbnOallolarySeMLB.com
STATE Of FLORIDA
ST. LUCI COUNTY
THIS T CERTIFYTHA TH IS
TRU N CORR T O Y O TH
ORIG li L.
r J r nlI L Mi H, Lf RK
Dater �=
BIG LAKE ROOFING
863-4F7-4618 P.1
Planning & Development Services
-j zjj:-_-2ZBuilding & Code Regulation Division
2300 Virginia Avenue
P Fort Pierce, FL 34982
772-462-2165 or 772-462-2172
Fax: 772-462-6443
ROOF INSPECTION AFFIDAVIT
Re: Permit# 1206-0127
I, _Joseph H. esker Jr. , licensed as a )2ontrZa�ctorEngineer/Architect
(Please print name & circle license type) *FS4 pector
*General, Building Residential ar Roofing Contractor crony individual certified under 468 F.S. to make such an inspection.
On or about 06/14/2012 ,1 did personally inspect the roof deck nailine
(Date)
work at: 8003 Kenwcod Road
(Job site address)
.Based upon that examination I have determined the installation was done according to the Hurricane
Mitigation Retrofit Manual (Based on 553.844 F.S.)
Signature and'Seal
STATE OF FLORIDA
COUNTY OF ST LUCTE
CCC.o469,39
License #
RECEIVED
j11N 13 2012
Sworn to and subscribed before me this 14 day of June 20J
by Josenh H. Baker Jr. Who is personally known to me or who has produced
as identification.
Notary Public, State of Flori
Signature of Notary:` el 11✓
Commission Number: DD9042 Sirl°A- if1lrCl t`�IV� AAi7Ohl
I'AY COf��i81i5SI0N # OD904290
En 01/19/2011 r { �=
�..1; . E):PIRES.luly 01, 2013
(4UiJSi:3•U i°iU F•onu:ranir:ry5trvix.com
r-
M I A M I•DAQE
BUILDING CODE COMPLIANCE OFFICE (BCCO)
PRODUCT CONTROL DIVISION
NOTICE OF ACCEPTANCE
Owens Corning
One Owens CorningParkway
Toledo, OH 43659
MIANH-DADE COUNTY, FLORIDA
METRO-DADE FLAGLER BUILDING
140 WEST FLAGLER STREET, SUITE 1603
MIAMI, FLORIDA 33130-1563
(305) 375-2901 FAX (305) 375-2908
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted
by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by
the Authority Having Jurisdiction (AIM).
This NOA shall not be valid after the expiration date stated below. The Miami Dade County Product Control
Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right
to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code,
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Supreme AR 3 Tab Shingles .
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall
be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This renews NOA #06-1113.06 and consists of pages 1 through 4.
The submitted documentation was reviewed by Alex Tigera.
�eA--- 91 ' LE COPY
NOA No.: 07-1116.12
Expiration Date: 03/20/13
MIAMNDAD; COUNTY Approval Date: 02/14/08
Page 1 of 4
l ,
f
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub -Category: 07310 Asphalt Shingles
Materials 3-Tab
Deck Type: Wood
1. SCOPE
This renews Owens Corning Supreme AR as manufactured by Owens Corning described in Section 2 of
this Notice of Acceptance.
2. PRODUCT DESCRIPTION
- Product Dimensions
Supreme AR 12" x 36"
3. EVIDENCE SUBMITTED:
Test Agency
Underwriters Laboratories, Inc.
Underwriters Laboratories, Inc.
Underwriters Laboratories, Inc.
PRI Asphalt Technologies, Inc.
Test Product Description
Specifications
TAS 110 A heavy weight, fiberglass reinforced
asphalt shingle.
Test Identifier
Test Name/Reyort
Date
02NK45241
ASTM D 3462
12/05/97
05CA53426
12/02/05
02NK45241
TAS 107
11/14/02
03NK04954
03/20/03
04CA52475
03/23/05
06CA03524
03/30/06
04NK40618
11/12/04
R2453
Reference
01/09/03
OCF-067-02-01
TAS 100
11/12/02
OCF-076-02-01
02/24/04
OCF-094-02-01
08/29/06
OCF-095-02-01
09/22/06
4. LE%HTATIONS
4.1 Fire classification is not part of this acceptance; refer to a current Approved Roofing
Materials Directory for fire ratings of this product.
4.2 Shall not be installed on roof mean heights in excess of 33 ft.
5. INSTALLATION
5.1 Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
5.2 Flashing shall be in accordance with Roofing Application Standard RAS 115
5.3 The manufacturer shall provide clearly written application instructions.
5.4 Exposure and course layout shall be in compliance with Detail 'A', attached.
5.5 Nailing shall be in compliance with Detail B', attached.
NOA No.: 07-1116.12
MIAMFDADE COMMiration Date: 03/20/13
OUNTY
. Approval Date: 02/14/08
Page 2 of 4
6. LABELING
6.1 Shingles shall be labeled with the Miami Dade Logo or the wording "Miami -Dade County
Product Control Approved".
7. BUILDING PERMIT REQUIREMENTS
7.1 Application for building permit shall be accompanied by copies of the following:
7.1.1 This Notice of Acceptance.
7.1.2 Any other documents required by the Building Official or the applicable code in
order to properly evaluate the installation of this system
8. MANUFACTURING PLANTS
8.1
Atlanta, GA
8.2
Jacksonville, FL
8.3
Irving, TX
8.4
Memphis, TN.
8.5
Jessup, MN.
8.6
Medina, OH.
NOA No.: 07-1116.12
Expiration Date: 03/20/13
Approval Date: 02/14/08
Page 3 of 4
9
EXPOSURE 5"
FUMATM1
DETAIL B
36"
NAILS ADHESIVE STRIPE
" 5R511 �10
8
END OF THIS ACCEPTANCE
NOA No.: 07-1116.12
Expiration Date: 03/20/13
Approval Date: 02/14/08
Page 4 of 4
1u
12"
M I A M I•DADE
BUILDING CODE COMPLIANCE OFFICE (BCCO)
PRODUCT CONTROL DIVISION
NOTICE OF ACCEPTANCE (NOA)
TAMKO Building Products, Inc.
P.O. Bog 1404
220 West 0 Street
Joplin, MO 64801
MIAMI-DADE COUNTY, FLORIDA
METRO-DADE FLAGLER BUILDING
140 WEST FLAGLER STREET, SUITE 1603
MIAMI, FLORIDA 33130-1563
(305) 375-2901 FAX (305) 375-2908
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building
Code and Product Review Committee to be used in Miami Dade County and other areas where allowed
by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product
Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County)
reserve the right to have this product or material tested for quality assurance purposes. If this product or
material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing
and the AHJ may immediately revoke, modify, or suspend the use of such product or material within
their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade
County Product Control Division that this product or material fails to meet the requirements of the
applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code and the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Tamko Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state
and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted
herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has
been no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or
change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an
endorsement of any product, for sales, advertising or any other purposes shall automatically terminate
this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of
NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed, then it shall be done in its entirety.
E cor"
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufactur
distributors and shall be available for inspection at the job site at the request of the Building R11cial.
This NOA revises NOA No. 07-1130.01 and consists of pages 1 through f.
The submitted documentation was reviewed by Jorge L. Acebo.
- NOA No.: 08-1008.04
Expiration Date: 07/05/12
MIAMICADECOUNTY Approval Date: 02/25/09
Page 1 of 5
ROOFING ASSEMBLY APPROVAL
Category:
Roofing
Sub -Category:
Underlayment
Material:
SBS
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Test
Product
Product
Dimensions Specification
Description
TW Metal and Tile
75 mils thickness TAS 103
Flexible, self -adhering rubberized asphalt sheet
Underlayment
39-%" x 30.5'rolls ASTM D 1970
material with a polymer surface for use as an
(Manufactured in Joplin,
39 '/a" x 6l' rolls
underlayment in sloped roof assemblies. May be
MO)
4" x 66' rolls
used as a secondary water barrier for full -roof
6" x 66' rolls
coverage or, when cut into appropriate width strips,
9" x 66' rolls
for taping sheathing joints.
Moisture Guard Plus
60 mils thickness ASTM D 1970
Flexible, self -adhering rubberized asphalt sheet
(Manufactured in Joplin,
39 3/B" x 30.5'rolls
material with a granular surface for use as an
MO)
.
39 %" x 45' rolls
underlayment in sloped roof assemblies. May be
39 %" x 61' rolls
used as a secondary water barrier for full -roof
4" x 66' rolls
coverage or, when cut into appropriate width strips,
6" x 66' rolls
for taping sheathing joints.
9"x66'rolls
TW Underlayment
40 mils thickness ASTM D 1970
Flexible, self -adhering rubberized asphalt sheet
(Manufactured in
39 %" x 61' rolls
material with a polymer surface for use as an
Columbus, KS)
4" x 66' rolls
underlayment in sloped roof assemblies. May be
6" x 66' rolls
used as a secondary water barrier for full -roof
9" x.66' rolls
coverage or, when cut into appropriate width strips,
for taping sheathing joints.
Awaflex
125 mils thickness TAS 104
SBS modified cap sheet with a non- woven polyester
(Manufactured in Joplin,
35.9' x 36" rolls
mat saturated with asphalt, coated on both sides with
MO)
SBS rubber modified asphalt and surfaced with
ceramic.granules.. Applied in hot asphalt.
Awaplan 17C
145 mils thickness TAS 104
A polyester reinforced SBS modified bitumen
(Manufactured in Joplin,
33' 11" x 39 3/8"
membrane surfaced with granules. Applied in hot
MO)
rolls
asphalt.
Awaplan Premium M
150 mils thickness TAS 104
A polyester reinforced SBS modified bitumen
(Manufactured in Joplin
33' 11" x 393/8"
membrane surfaced with granules. Applied in hot
MO)
rolls
asphalt.
Tatnko SA Base
60 mils thickness ASTM D 1970
A fiberglass -reinforced self -adhering SBS modified
(Manufactured in Joplin,
65' 10" x 39 3/8'
bitumen membrane with a polymer film on the
MO)
rolls
surface and a removable treated split release film on
the adhesive side. Shall only be mechanically
fastened to wood deck. Direct adhesion to wood
deck not permitted in the HVHZ. Do Not Remove
Release Film!
Tamko SA Cap
140 mils thickness ASTM D 6164
A dual -coated SBS-modified cap sheet with a
(Manufactured in Joplin
33' 6'/0" x 39 3/8"
nonwoven polyester mat surfaced with ceramic
MO)
rolls
granules and a split removable release film on the
adhesive side.
NOA No.: 08-1008.04
Expiration Date: 07/05/12
Approval Date: 02/25/09
Page 2 of 5
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Reaort Date
Exterior Research & Design, LLC 4448.12.01-1 TAS 103 12/19/2001
4448.05.02-1 TAS 103 05/29/2002
Trinity I ERD
T11090.09.08 TAS 117(B)/ TAS 114(C) 09/18/08
PRI Asphalt Technologies, Inc. TAP-058-02-01 TAS 103 04/30/02
TAP-058-02-02 TAS 103 05/23/02
TAP-191-02-01 ASTM D 1970 11/16/07
TAP-192-02-01 ASTM D 1970 11/13/07
TAP-193-02-01 ASTM D 1970 11/16/07
TAP-207-02-OIREV TAS 104/ ASTM D 4798 12/10/08
TAP-185-02-OIREV ASTM D 6164 11/06/08
TAP-196-02-01 ASTM D 1970 01/09/08
APPROVED ASSEMBLIES:
Deck Type 1:
Wood, Non -insulated
Deck Description:
19/32' or greater plywood or wood plank
System E(1):
Anchor sheet mechanically fastened to deck, membrane adhered.
Base Sheet:
One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4" side
lap and a 6" end lap mechanically fastened to deck with approved annular ringshank
nails and tin caps 6" o.c. at the laps and two staggered rows 12" o.c. the field of the roll.
Membrane:
One or more plies of TW Metal and Tile Underlayment with a minimum 4" side lap
and 6" end lap. Place the first course of membrane parallel to the cave, rolling the
membrane to obtain maximum contact. Remove the release liner as the membrane is
applied. Vertical strapping of the roof with TW Metal and Tile Underlayment is
acceptable.
When used in Tile roof systems the capsheet shall be back nailed to deck with approved
annular ring shank nails and tin caps at a maximum 12"° o.c. at the side laps and 6" o.c.
at the end laps. No nails or tin caps shall be exposed.
Surfacing:
Approved Mechanically Fastened Tile or Metal Roofing Assembly or Any Approved
Roofing Assemblies where an ASTM D 1970 underlayment is allowed.
Deck Type 1:
Wood, Non -insulated
Deck Description:
19/32' or greater plywood or wood plank
System E(2):
Anchor sheet mechanically fastened to deck, membrane adhered.
Base Sheet:
One or more plies of ASTM D 226 Type H or ASTM D 2626 with a minimum 4" side
lap and a 6" end lap mechanically fastened to deck with approved annular ringshank
nails and tin caps 6" o.c. at the laps and two staggered rows 12" o.c. the field of the roll.
Membrane:
One or more plies of Moisture Guard Plus with a minimum 3.5" side lap and 6" end
lap. Place the first course of membrane parallel to the cave, rolling the membrane to
obtain maximum contact. Remove the release liner as the membrane is applied. Vertical
strapping of the roof with Moisture Guard Plus is acceptable.
Surfacing:
Any Approved Roofing Assemblies where an ASTM D 1970 underlayment is allowed.
NOA No.: 08-1008.04
Expiration Date: 07/05/12
Approval Date: 02/25/09
Page 3 of 5
Deck Type 1:
Wood, Non -insulated
Deck Description:
19/32' or greater plywood or wood plank
System E(3):
Anchor sheet mechanically fastened to deck, membrane adhered.
Base Sheet:
One or more plies of ASTM D 226 Type 11 or ASTM D 2626 with a minimum 4" side
lap and a 6" end Iap mechanically fastened to deck with approved annular ringshank
nails and tin caps 6" o.c. at the laps and two staggered rows 12" o.c. the field of the roll.
Membrane:
One or more plies of TW Underlayment with a minimum 4" side lap and 6" end lap.
Place the first course of membrane parallel to the eave, rolling the membrane to obtain
maximum contact. Remove the release liner as the membrane is applied. Vertical
strapping of the roof with TW Underlayment is acceptable.
Surfacing:
Any Approved Roofing Assemblies where an ASTM D 1970 underlayment is allowed.
Deck Type 1: Wood, Non -insulated
Deck Description: 19/32' or greater plywood or wood plank
System E(4): Anchor sheet mechanically fastened to deck, membrane adhered.
Base Sheet: One or more plies of ASTM D 226 Type 11 or ASTM D 2626 with a minimum 4" side
lap and a 6" end lap mechanically fastened to deck with approved annular ringshank
nails and tin caps 6" o.c. at the laps and two staggered rows 12" o.c. the field of the roll.
Membrane: One or more plies of Awaflex, Awaplan 170 or Awaplan Premium applied at a right
angle (90) to the slope of the deck adhered in a full mopping of approved asphalt
applied within the EVT range and at a rate of 20-40 lbs./sq. Vertical strapping of the
roof with Awaflex, Awaplan 170 or Awaplan Premium underlayments is acceptable.
When used in Tile roof systems the capsheet shall be back nailed to deck with approved
annular ring shank nails and tin caps at a maximum 12" o.c. at the side laps and 6" o.c.
at the end laps. No nails or tin caps shall be exposed.
Surfacing: Approved Mechanically Fastened or Adhered Tile or Metal Roofing Assembly or Any
Approved Roofing Assemblies where an TAS 104 underlayment is allowed.
Deck Type 1: Wood, Non -insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(5): Anchor sheet mechanically fastened to deck, membrane adhered.
Base Sheet: One or more plies of Tamko SA Base with a minimum 4" side lap and a 6" end lap
mechanically fastened to deck with approved annular ringshank nails and tin caps 6"
o.c. at the laps and two staggered rows 12" o.c. the field of the roll. Shall only be
mechanically fastened to wood deck. Direct adhesion to wood deck not permitted
in the HVHZ. Do Not Remove Release Film!
Membrane: One or more plies of Tamko SA Cap with a minimum 4" side lap and 6" end lap. Place
the first course of membrane parallel to the eave, rolling the membrane to obtain
maximum contact with base sheet. Remove the release liner as the membrane is
applied. Vertical strapping of the roof with Tamko SA Cap underlayment is acceptable.
When used in Tile roof systems the capsheet shall be back nailed to deck with approved
annular ring shank nails and tin caps at a maximum 12" o.c. at the side laps and 6" o.c.
at the end laps. No nails or tin caps shall be exposed
Surfacing: Approved Mechanically Fastened Tile or Metal Roofing Assembly or Any Approved
Roofing Assemblies where an ASTM D 6164 membrane is allowed.
NOA No.: 08-1008.04
Expiration Date: 07/05/12
Approval Date: 02/25/09
Page 4 of 5
GENERAL LEW[TATIONS:
1. Fire classification is not part of this acceptance.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in
compliance with applicable building code. Tamko Underlayments shall be installed in strict
compliance with applicable Building Codes.
3. All Tamko Underlayments shall be applied to a smooth, clean and dry surface with deck free of
irregularities. Deck shall be fastened in strict compliance with applicable Building Codes.
4. All Tamko Underlayments shall not be applied over an existing roof membrane as a recover system
but may be applied over an approved roofing Base/Anchor sheet underlayment.
5. TW Metal and Tile Underlayment, Moisture Guard Plus, TW Underlayment, Tamko SA Base &
Tamko SA CAP shall not be left exposed as a temporary roof for longer than 30 days of application.
6. Awaflex, Awaplan 170 and Awaplan Premium shall not be left exposed as a temporary roof for
longer than 180 days of application.
7. The standard maximum roof pitch for Awaflex, Awaplan 170 and Awaplan Premium shall be 6:12
- for flat tile installation and 6:12 profiled tiles with lugs.
8. The standard maximum roof pitch for TW Metal and Tile Underlayment and Tamko SA CAP shall
be 4:12 for flat tile installation and 4:12 profiled tiles with lugs.
9. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this
product with specific prepared roofing products.
10. Tile storage shall be on a battened roof deck when the underlayment slope limit (See #7 & #8 above)
is exceeded. Care should be taken during the loading procedure to keep foot traffic to a minimum
and to avoid dropping of tile directly on the underlayment.
11. The Tamko Underlayments may be used with any approved roof covering Notice of Acceptance
listing the Tamko Underlayment as a component part of an assembly in the Notice of Acceptance. If
Tamko Underlayments are not listed, a request may be made to the Authority Having Jurisdiction
(AHJ) or the Miami -Dade County Product " Control Department for approval provided that
appropriate documentation is provided to detail compatibility of the products, wind uplift resistance,
and fire testing results.
12. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking
panels. Sweep the deck thoroughly to remove any dust and debris prior to application.
13. When applying the membrane in the valley, start at the low point and work to the high point, rolling
the membrane from the center outward in both directions. For ridge applications, center the
membrane and roll from the center outward in both directions.
14. For the self adhered membranes roll or broom the entire membrane surface so as to have 100%
contact with the base sheet, giving special attention to overlap areas.
15. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current
Product Control Notice of Acceptance and applicable Building Code.
16. All protrusions or drains shall be initially taped with a 6" piece of approved Tamko Underlayment.
The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A
second layer of the same Tamko Underlayment shall be applied over the taped underlayment.
17. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's
name or logo, city, state and the following statement: "Miami -Dade County Product Control
Approved" or the Miami -Dade County Product Control Seal as shown below.
MIAMNDADE COUNTY
END OF THIS ACCEPTANCE
NOA No.: 08-1008.04
Expiration Date: 07/05/12
Approval Date. 02/25/09
Page 5 of 5