Loading...
HomeMy WebLinkAboutSUBMITTED PAPERS_2FL # FL1654-R10 Application Type Revision Code Version 2010 Application Status Approved Comments Archived Product Manufacturer POLYGLASS USA Address/Phone/Emall 150 Lyon Drive Fernley, NV 89408 (570) 384-1230 Ext242 jakins@polyglass.com Authorized Signature James Akins jakins@polyglass.com Technical Representative James Arnold, PE, RRO Address/Phone/Email 10475 Park Meadows Drive Suite 600 Lone Tree, CO 80124 (720) 279-2348 jarnold@polyglass.com Quality Assurance Representative James Akins Address/Phone/Email 555 Oakridge Road Humboldt Industrial Pkwy Hazleton, PA 18201 (800)894-4563 jakins@polyglass.com Category Roofing Subcategory Modified Bitumen Roof System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who Robert Nleminen developed the Evaluation Report Florida License PE-59166 Quality Assurance Entity Underwriters Laboratories Inc. Quality Assurance Contract Expiration Date 11/30/2012 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL1654 R10 COI Trinity ERD CI - Nieminen.odf Referenced Standard and Year (of Standard) Standard Year ASTM D6163 2000 ASTM D6164 2005 http://www.floridabuilding. org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvgqu2w%2bnFg... 6/8/2012 Florida Building Code Online Page 2 of 2 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved ASTMD6222 2002 FM 4470 1992 FM 4474 2004 Method 1 Option D 12/09/2011 12/10/2011 12/20/2011 01/31/2012 ....................................................... Summary of Products FL # IlModel, Number or Name i Description 1654.1 Polyglass SBS and APP SBS and APP modified bitumen roof systems ]Systems Modified Bitumen Roof Limits of Use Approved for use in HVHZ: No Installation Instructions FL1654 R10 II Al ER120611FINAL POLYGLASS MODBIT FL1654- R10.odf Verified By: Robert Nieminen PE-59166 Created by Independent Third Party: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-622.5 Other: 1.) The design pressure in this application relates to one particular assembly Evaluation Reports FL1654 RIO AE ER1.20611FINAL POLYGLASS MODBIT FL1654- RSO.Ddf over concrete deck. Refer to the ER Appendix for other systems and deck types. 2.) Refer Created by Independent Third Party: Yes to ER, Section 5 for other Limits of Use. Back Next Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Cooyricht 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, e-mail addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions regarding DBPR's ADA web accessibility, please contact our Web Master at webmasterCaldbor.state.fl.us. Product Approval Accepts: e a— ok6 'SrE't f:ox.rwssS U'�WASIgn http://www.floridabuilding.org/pr/P _app_dtl.aspx?param=wGEVXQwtDgvgqu2w°/D2bnFg... 6/8/2012 OTRR IN IT ERD Certificate of Authorization #9503 August 01, 2011 RE: Certification of Independence, Florida F.A.C. Rule 9N-3 To Whom It May Concern: This letter serves to document the following in accordance with Florida F.A.C. Rule 9N-3: I . Exterior Research & Design, LLC. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. Please contact our office with any questions. Sincerely, Robert Nieminen, P.E. Florida Reg. No. 59166 Vice President Email: robertnieminen@trinityerd.com EXTERIOR RESEARCH & DESIGN, LLC. d/b/a TrinitylERD - Certificate of Authorization #9503 MAIN: 80 Yesler Way . Suite 200 . Seattle, WA 98104 . P: (206) 467-0054 . F: (206) 467-5840 EAST: 353 Christian Street Unit 13 . Oxford, CT 06478 . P: (203) 262-9245 . F: (203), 262-9243 III APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE Table Deck Application Type Description Page 1A-1 Wood New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 4 IA-2 Wood New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 5 1B Wood New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 6 1C Wood New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 6 1D Wood New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 7 1E Wood New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 8-9 1F Wood New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 9 2A Steel or Conc. New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 10 2B Steel or Conc. New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 10 2C Steel or Conc. New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 11 3A-1 Concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 12-15 3A-2 Concrete New or Reroof (Tear -Off) A-1 Bonded Temporary Roof, Bonded Insulation, Bonded Roof Cover 16 3B Concrete New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 17 4A LWIC New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 18-19 4B LWIC New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 19 4C LWIC New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 20-23 5A CWF New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 24 5B CWF New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 25 5C CWF New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 25 5D CWF New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 26 5E CWF New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 26 6A Gypsum New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 27 6B Gypsum New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 28 6C Gypsum New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 28 6D Gypsum New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 28 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 29-30 7B Various Recover F Non -Insulated, Bonded Base Sheet, Bonded Roof Cover 30 The following notes apply to the systems outlined herein: 1. Roof decks shall be in accordance with FBC requirements to the satisfaction of the AHJ. Wind load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement: ➢ Wood: Minimum 0.75-inch penetration. ➢ Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck. ➢ Concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions. 3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyan u rate, polystyrene, wood fiberboard, perlite, DensDeck, DensDeck Prime, DensDeck DuraGuard, SECUROCK Gypsum -Fiber Roof Board or SECUROCK Glass -Mat Roof Board that meets the QA requirements of F.A.C. Rule 9N-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC 2603.4.1 or 2603.6, when installed with the roof cover. Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report P9290.02.08-R8 for FL1654-RlO Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 1 of 30 QOTRINITYIERD 4. Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the base sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. 5. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published instructions. ➢ HA (HA): Full coverage at 25-30 Ibs/square. ➢ Dow Insta-Stik Roofing Adhesive (D-IS): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. ➢ Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c. ➢ OMG OlyBond 500 (013500): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. (PaceCart or SpotShot). Note: OlyBond Green may be used where OlyBond 500 is referenced. ➢ OlyBond Classic (OB Classic): Full coverage at 1 gal/square. ➢ 3M CR-20: Continuous 2.5-3.5-inch wide ribbons, 12-inch o.c. Note: TITESET may be used where CR-20 is referenced. ➢ Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon -applied adhesive, adhesive ribbons shall be staggered from layer -to -layer a distance of one-half the ribbon spacing. ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 6. Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocya n u rate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to 'increase' the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table: ➢ Millennium One Step Foamable Adhesive (M-OSFA): MDP -157.5 psf (Min. 0.5-inch thick) ➢ OMG OlyBond 500 (013500): MDP -45.0 psf (Min. 0.5-inch thick Multi -Max FA-3) ➢ OMG OlyBond 500 (013500): MDP -187.5 psf (Min. 0.5-inch thick ISO 95+ GL) ➢ OMG OlyBond 500 (013500): MDP -315.0 psf (Min. 0.5-inch thick ENRGY 3) ➢ OMG OlyBond 500 (013500): MDP -487.5 psf (Min. 0.5-inch thick ACFoam II) ➢ 3M CR-20: MDP -117.5 psf (Min. 1.0-inch thick) 7. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. 8. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are PAS 117 and FM LPDS 1-29. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3 enhancements. 9. For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted. 10. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI FX-1. 11. For existing substrates in a bonded recover installation, the existing roof system shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the AHJ, as documented through field uplift testing in accordance with ASTM E907, FM LPDS 1-52, ANSI/SPRI IA-1 or TAS 124. 12. For Recover Applications using System Type D, the insulation is optional; however, the existing roof system shall be suitable for a recover application. Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 2 of 30 13. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications. Table 1: Polyglass Roof Covers Reference Layer Material Application BP -AA Base Polyglass G2 Base, Modibase, FBC Approved ASTM D4601, Type II HA at 20-40 (Base and Ply sheets, Asphalt -Applied) Ply FBC Approved ASTM D2178, Type IV or VI or ASTM D4601, Type II Ibs/square Base or Ply Elastobase, Elastobase Poly, Elastoflex V, Elastoflex S6 HA 20-40 SBS-AA (SBS, Asphalt -Applied) Cap Elastoflex S6, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, Elastoshield TS-G FR, Polyfresko at Ibs/square MOP, Polyfresko MOP FR Base or Ply Elastoflex V, Elastoflex S6 SBS-TA (SBS, Torch -Applied) Cap Elastoflex V, Elastoflex S6, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, Elastoshield TS-G Torch -Applied FR, Polyfresko MOP, Polyfresko MOP FR SBS-SA Base Elastoflex SA V Base, Elastoflex SA V FR Base, Elastoflex SA V Plus, Elastoflex SA V Plus FR Self (SBS, Self -Adhering) Cap Elastoflex SA P, Elastoflex SA P FR, Polyfresko SBS SAP, Polyfresko SBS SAP FR -Adhering APP-TA Base or Ply Polyflex, Polybond Torch (APP, Torch -Applied) Cap Polyflex, Polyflex G, Polyflex G FR, Polybond, Polybond G, Polyfresko Torch, Polyfresko Torch FR -Applied APP-SA Cap Polyflex SA P, Polyflex SA P FR, Polyfresko APP SAP, Polyfresko APP SAP FR, Polykool, Polybianko Self -Adhering (APP, Self -Adhering) 14. Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind load performance. Refer to current Roofing Materials Directory for fire ratings associated with coating usage. ➢ PG200 Non Fibered Roof Coating or Mule -Hide 111 Non-Fibrated Roof Coating; ➢ PG300 Fibered Roof Coating or Mule -Hide 102 Fibrated Roof Coating; ➢ PG600 Non-Fibered Aluminum Roof Coating or Mule -Hide 416 Standard Non-Fibrated Aluminum Roof Coating; ➢ PG650 Fibered Aluminum Roof Coating or Mule -Hide 406 Standard Fibrated Aluminum Roof Coating; ➢ PG700 White Reflective Roof Coating; ➢ PG800 Non-Fibered Asphalt Emulsion Roof Coating or Mule -Hide 311 Emulsion Non-Fibrated; ➢ PG850 Fibered Asphalt Emulsion Roof Coating or Mule -Hide 301 Emulsion Fibrated; ➢ Polyplus 60 Premium Non-Fibered Aluminum Roof Coating or Mule -Hide 410 Premium Non-Fibrated Aluminum Roof Coating; ➢ Polyplus 65 Premium Fibered Aluminum Roof Coating or Mule -Hide 401 Premium Fibrated Aluminum Roof Coating; ➢ Polybrite 70 White Elastomeric Roof Coating. 15. The following represent priming requirements for gypsum -based coverboards: ➢ DensDeck and DensDeck Prime shall be field -primed with PG100 prior to self -adhering or torch -applied membrane application. No priming is required for hot -asphalt membrane applications. ➢ SECUROCK Gypsum -Fiber Roof Board or DensDeck DuraGuard do not require field priming for any membrane application. 16. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609.1.5 for determination of design wind loads. Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report P9290.02.08-RS for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 3 of 30 QOTRINITYIERD TABLE IA-1: WOOD DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System Anchor Sheet Base Insulation Top Insulation Roof Cover MOP No. Roof Deck Type Fasteners Attach Type Attach Type Attach Base Ply Cap (psf) Min. 19/32-inch Elastobase, Elastobase 32 ga., 1- 8-inch o.c. in 4-inch lap (Optional) Min. 0.25-inch DensDeck, DensDeck plywood at max. Poly, Polyglass G2 Base, CertainTeed 5/6-inch diameter tin and 8-inch FBC Approved, Prime, SECUROCK (Optional) SBS-AA, W-1 24-inch spans Glasbase, Firestone caps with 11 o.c. in three, equally ASTM C1289, HA Gypsum -Fiber Roof Board, Min. 0.75-inch HA BP -AA or SBS-AA BP -AA or SBS-TA, -52.5 attached 6-inch o.c. with 8d MB BaseJM Perma- , ga. annular spaced, type II FescoBoard or min. SBS-AA APP-TA common nails Ply 28, Tamko Glass ring shank staggered polyiso- inch Structodek Base or GAFGLAS #75 nails center rows cyanurate HD HD Fiberboard Min. 19/32-inch Elastobase, Elastobase 32 ga., 1 8-inch o.c. in 4-inch lap (Optional) (Optional) plywood at max. Poly, Polyglass G2 Base, CertainTeed 5/8-inch diameter tin and 8-inch FBC Approved, Min. 0.25-inch DensDeck, DensDeck One or SBS-SA, W-2 spans Glasbase, Firestone caps with 11 11 three, equally equally ASTM C1289, HA Prime, SECUROCK HA SBS-SA more SBS-SA, APP-SA, SBS-TA or -52.5 attache attached 6-inch with 8d MB Base, JM Perma- ga. annular spaced, type II Gypsum -Fiber Roof SBS-TA or APP-TA o.c. common nails Ply 28, Tamko Glass ring shank staggered polyiso- Board APP-TA Base or GAFGLAS #75 nails center rows cyanurate Min. 19/32-inch 32 ga., 1- 8-inch o.c. in (Optional) Min. 0.25-inch plywood at max. Polyglass G2 Base, 5/8-inch 4-inch lap FBC DensDeck, DensDeck 24 inch spans CertainTeed Glasbase, diameter tin and 8-inch Approved, Prime, SECUROCK (Optional) SBS-AA, W-3 attached 4-inch Firestone MB Base, JM caps with 11 o.c. in three, ASTM C1269, HA Gypsum -Fiber Roof HA BP -AA or BP -AA or SBS-TA, -60.0 o.c. with 8d Perma-Ply 28, Tamko ga. annular equally type II Board, Min. 0.75-inch SBS-AA SBS-AA APP-TA common nails or Glass Base or ring shank spaced, polyiso- FescoBoard or min. 6-inch o.c. with GAFGLAS #75 nails staggered cyanurate 0.5-inch Structodek #8 screws center rows HD Fiberboard Min. 19/32-inch plywood at max. Polyglass G2 Base, 32 ga., 1- 5/8-inch 8-inch o.c. in 4-inch lap (Optional) FBC Min. 0.25-inch (Optional) 24-inch spans CertainTeed Glasbase, diameter tin and 8-inch Approved, DensDeck, DensDeck One or more SBS-SA, APP-SA, W-4 attached 4-inch Firestone MB Base, caps with li three, 11 ASTM C1269, HA Prime, SECUROCK HA SBS-SA SBS-SA, SBS-TA or -60.0 o.c. with 8d Perma-Ply 28, Tamkoo Base ga. annular equally equy type II Gypsum -Fiber Roof SBS-TA or APP-TA common nails or Glass or ring shank spaced, polyiso- Board APP-TA 6-inch o.c. with GAFGLAS #75 nails staggered cyanurate #8 screws center rows Min. 19/32-inch 32 ga., 1- 6-inch o.c. in D-IS, plywood at max. 5/8-inch 4-inch lap Min. 2-inch OB500, CR- Min. 0.25-inch 24-inch spans attached 4-inch Elastobase or diameter tin and 6-inch O.C.in four, ACFoam II, III, H-Shield, 20 or M- DensDeck, DensDeck OB50 OB500, BP -AA or (Optional) BP -AA or SBS-AA, SBS-TA, -60.0 W-5 o.c. with 8d Elastobase Poly caps with 12 ga. annular equally H-Shield CG, OSFA, atop fastener Prime or SECUROCK Gypsum -Fiber Roof CR-20 or SBS-AA SBS-AA APP-TA common nails or ring shank spaced, Multi -Max FA3 rows, 7- Board M-OSFA 6-inch o.c. with nails staggered or ENRGY-3 inch oc #8 screws center rows Min. 19/32-inch plywood max. 32 ga., 1- 32 ga., 6-inch o.c. in 4-inch lap Min. 2-inch D-IS, (Optional) 24-inch spans p diameter tin and 6-inch ACFoam II, OB500, CR- 20 or M- (Optional) Additioal One or SBS-SA, APP-SA, W-6 attached 4-inch Elastobase or Poly caps with 12 O.C.in four, equally III, H-Shield, H-Shield CG, OSFA, atop layers of base OB500, OB50 CR-20 or SBS-SA more SBS-SA, SBS-TA or -60.0 o.c. with 8d common nails or Elastobase ga. annular spaced, Multi -Max FA3 fastener insulation M-OSFA SBS-TA or APP-TA 6-inch o.c. with ring shank nails staggered or ENRGY-3 rows, 7- inch oc APP-TA #8 screws center rows Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report P9z9u.uz.Uti-Rts tor ru654-Riu Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 4 of 30 Fyo TABLE IA-2: WOOD DECKS — NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System Anchor Sheet Base Insulation Top Insulation Roof Cover MDP No. Roof Deck Type Fasteners Attach Type Attach Type Attach Base Ply Cap (Psf) Elastobase, OMG Flat 12-inch o.c. Min. 0.25-inch Min. 19/32-inch Elastobase Poly, Bottom Plates in 4-inch lap (Optional) DensDeck, DensDeck plywood at Polyglass G2 Base, (square) with and 12-inch FBC Prime, SECUROCK max. 24-inch CertainTeed Roofgrip #14, O.C.n two, Approved, Gypsum -Fiber Roof BP -AA or (Optional) SBS-AA, W-7 spans attached Glasbase, Firestone Dekfast HexTM . equally C1289, HA Board, Min. 0.75- HA SBS-AA BP -AA or SBS-TA, -52.5 6-inch o.c. with MB Base, IM Perma- with Dekfast spaced, type II inch FescoBoard or SBS-AA APP-TA 8d common Ply 28, Tamko Glass #14 or TruFast staggered polyiso- min. 0.5-inch nails Base or GAFGLAS MP-3 with center rows cyanurate Structodek HD #75 TruFast HD Fiberboard Elastobase, OMG Flat 12-inch o.c. Min. 19/32-inch Elastobase Poly, Bottom Plates in 4-inch lap (Optional) plywood at Polyglass G2 Base, (square) with and 12-inch FBC Min. 0.25-inch (Optional) SBS-SA, max. 24-inch CertainTeed Roofgrip #14, O.C.pproved, two, DensDeck, DensDeck One or APP-SA, W-8 spans attached Glasbase, Firestone Dekfast Hex 11 ally equally ASTM C1289, HA Prime, SECUROCK HA SBS-SA more SBS- SBS-TA or -52.5 6-inch o.c. with MB Base, IM Perma- with Dekfast spaced type II Gypsum -Fiber Roof SA, SBS-TA APP TA 8d common Ply 28, Tamko Glass #14 or TruFast , staggered polyiso- Board or APP-TA nails Base or GAFGLAS MP-3 with center rows cyanurate #75 TruFast HD Min. 19/32-inch 12-inch o.c. Min. 0.25-inch plywood at in 4-inch lap (Optional) DensDeck, DensDeck max. 24-inch spans attached OMG Flat and 12-inch FBC Approved, Prime, SECUROCK Gypsum -Fiber Roof (Optional) SBS-AA, W-9 4-inch o.c, with Elastobase or Bottom Plates o.c. in two, ASTM C1289, HA Board, Min. 0.75- HA BP -AA or SBS-AA BP -AA or SBS-TA, -60.0 8d common Elastobase Poly (square) with equally type II inch FescoBoard or SBS-AA APP-TA nails or 6-inch Roofgrip #12 spaced, staggered polyiso- min. 0.5-inch o.c. with #8 center rows cyanurate Structodek HD screws Fiberboard Min. 19/32-inch 12-inch o.c. plywood at max. 24-inch in 4-inch lap (Optional) FBC Min. 0.25-inch (Optional) spans attached OMG Flat and 12-inch , Approved DensDeck , DensDeck One or SBS-SA, APP-SA, W-10 4-inch o.c. with Elastobase or Elastobase Poly Bottom Plates (square) with o.c. in two, equally ASTM C1289, HA Prime, SECUROCK HA SBS-SA more SBS- SBS-TA or -60.0 8d common Roofgrip #12 spaced, type II Gypsum -Fiber Roof SA, SBS-TA APP-TA nails or 6-inch staggered polyiso- Board or APP-TA o.c. with #8 center rows cyanurate screws Exterior Research and Design, LLC. d/b/a Trinity IERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 5 of 30 (---)o `-JTR1N1TYjERD TABLE iB: WOOD DECKS — NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System Base Insulation Layer Top Insulation Layer Roof Cover MDP No. Roof Deck Type Fasteners Attach Type Attach Base Ply Cap (psi Min. 19/32-inch plywood Min. 1.5-inch Dekfast Hex with Min. 0.75-inch (Optional if (Optional if using AA SBS-AA, W-11 at max. 24-inch spans ENRGY 3, H- Dekfast #12 or 1 per FescoBoard or min. HA using AA Ply) Base) One or more SBS-TA, -52.5 attached 6-inch o.c. with Shield or TruFast MP-3 with 1.33 ft' 0.5-inch Structodek BP -AA, SBS- BP -AA, SBS-AA, APP-TA 8d common nails Polytherm TruFast DP HD Fiberboard AA SBS-TA or APP-TA Min. 19/32-inch plywood Min. 1.5-inch Dekfast Hex with Min. 0.75-inch (Optional if (Optional if using AA SBS-AA, W-12 at max. 24-inch spans attached 4-inch o.c. with ENRGY 3, H- Dekfast #12 or 1 per FescoBoard or min, HA using AA Ply) Base) One or more SBS-TA, -60.0 8d common nails or 6- Shield or TruFast MP-3 with 1.33 ftZ 0.5-inch Structodek BP -AA, SBS- BP -AA, SBS-AA, APP-TA Polytherm TruFast DP HD Fiberboard AA SBS-TA or APP-TA inch o.c. with #8 screws TABLE 1C: WOOD DECKS — NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System Base Insulation Top Insulation Layer Roof Cover MDP No. Roof Deck Layer Type Fasteners Attach Base Ply Cap (psf) Min. 0.5-inch Structodek (Optional if using Min. 19/32-inch plywood (Optional) HD Fiberboard or min. Dekfast Galvalume (Optional if AA Base) One or W-13 at max. 24-inch spans One or more layers, 0.25-inch DensDeck, Steel Hex with 1 per z using AA Ply) more BP -AA, SBS- SBS-AA, SBS- TA, APP-TA -52.5 attached 6-inch o.c. with any combination, DensDeck Prime or Dekfast #12 DP 1.33 ft BP-AA,SBS-AA AA, SBS-TA or Bd common nails loose laid SECUROCK Gypsum-FiberAPP-TA Roof Board Min. 0.5-inch Structodek (Optional if using Min. 19/32-inch plywood (Optional) HD Fiberboard or min. Dekfast Galvalume (Optional if AA Base) One or W-14 at max. 24-inch spans One or more layers, 0.25-inch DensDeck, Steel Hex with 1 per using AA Ply) more BP -AA, SBS- SBS-AA, SBS- TA, APP-TA -67.5 attached 4-inch o.c. with any combination, DensDeck Prime or Dekfast #12 DP 1.33 ftZ BP -AA, SBS-AA AA, SBS-TA or Bd common nails loose laid SECUROCK Gypsum -Fiber APP-TA Roof Board Min. 0.5-inch Structodek (Optional if using Min. 19/32-inch plywood (Optional) HD Fiberboard or min. Dekfast Galvalume (Optional if AA Base) One or W-15 at max. 24-inch spans One or more layers, 0.25-inch DensDeck, Steel Hex with 1 per 2 using AA Ply) more BP -AA, SBS- SBS-AA, SBS- APP-TA -82.5 attached 6-inch o.c. with any combination, DensDeck Prime or Dekfast #12 DP 1.33 ft BP -AA, SBS-AA AA, SBS-TA or TA, #8 screws loose laid SECUROCK Gypsum -Fiber APP-TA Roof Board Min. 19/32-inch plywood (Optional) Dekfast Galvalume Steel Hex with (Optional) One or SBS-SA, APP- W-16 at max. 24-inch spans One or more layers, Min. 1.5-inch ENRGY 3, H- Dekfast #12 DP or 1 per 1.33 ftZ SBS-SA more SBS-SA, SA, SBS-TA or -82.5 attached 6-inch o.c. with an combination, y Shield or Polytherm TruFast MP-3 with SBS-TA or APP-TA APP-TA #8 screws loose laid TruFast DP Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 6 of 30 TABLE 1D: WOOD DECKS — NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER SYSTEM TYPE D: PRELIMINARILY ATTACHED INSULATION, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Insulation Layer(s) Base Sheet Roof Cover No. Roof Deck MOP (psf) Type Attach Base Fasteners Attach Ply Cap Elastobase, Elastobase Poly, OMG Flat Bottom Min. 19/32-inch Polyglass G2 Base, Plates (square) with 12-inch o.c. in 4-inch (Optional) One or plywood at max. 24- One or more Prelim. CertainTeed Glasbase, Roofgrip #14, lap and 12-inch o.c. more BP -AA, SBS-AA, SBS- W-17 inch spans attached layers, any Attached Firestone MB Base, JM Dekfast Hex with in two, equally SBS-AA, SBS-TA TA, APP-TA -52.5 6-inch o.c. with 8d combination Perma-Ply 28, Tamko Glass Dekfast #14 or spaced, staggered or APP-TA common nails Base or GAFGLAS #75 TruFast MP-3 with center rows TruFast HD OMG Flat Bottom Min. 19/32-inch Plates (square) with 12-inch o.c. in 4-inch plywood at max. 24- One or more Prelim. Elastobase or Elastobase Roofgrip #14, lap and 12-inch o.c. One or more SBS- SBS-SA, APP- W-18 inch spans attached layers, any Attached Poly with poly top surface Dekfast Hex with in two, equally SA, SBS-TA or SA, SBS-TA or -52.5 6-inch o.c. with 8d combination Dekfast #14 or spaced, staggered APP-TA APP-TA common nails TruFast MP-3 with center rows TruFast HD Min. 19/32-inch plywood at max. 24- 12-inch o.c. in 4-inch (Optional) One or inch spans attached One or more Prelim. Elastobase or Elastobase OMG Flat Bottom lap and 12-inch o.c. more BP -AA, SBS-AA, SBS- W-19 4-inch o.c, with 8d layers, any Attached Poly Plates (square) with in two, equally SBS-AA, SBS-TA TA, APP-TA -60.0 common nails or 6- combination Roofgrip #12 spaced, staggered or APP-TA inch o.c. with #8 center rows screws Min. 19/32-inch Plywood at max. 24- 12-inch o.c. in 4-inch inch spans attached One or more Prelim. Elastobase or Elastobase OMG Flat Bottom lap and 12-inch o.c. One or more SBS- SBS-SA, APP- W-20 4-inch o.c. with 8d layers, any Attached Poly with poly top surface Plates (square) with in two, equally SA, SBS-TA or SA, SBS-TA or -60.0 common nails or 6- combination Roofgrip #12 spaced, staggered APP-TA APP-TA inch o.c. with #8 center rows screws Exterior Research and Design, LLC. d/b/a Trinity IERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 7 of 30 TABLE 1E: WOOD DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE E: NON-INSULATEDr MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Base Sheet Roof Cover No. Roof Deck MDP (psf) Base Fasteners Attach Ply Cap Min. 19/32-inch plywood at Elastobase, Elastobase Poly, Polyglass 32 ga., 1-5/8-inch diameter 8-inch o.c. in 4-inch lap (Optional) One or W-21 max. 24-inch spans attached G2 Base, CertainTeed Glasbase, tin caps with 11 ga. annular and 8-inch o.c. in more BP -AA, SBS-AA, SBS- -52.5 6-inch o.c. with Bd common Firestone MB Base, JM Perma-Ply 28, ring shank nails three, equally spaced, SBS-AA, SBS-TA TA, APP-TA nails Tamko Glass Base or GAFGLAS #75 staggered center rows or APP-TA Min. 19/32-inch plywood at 32 ga., 1-5/8-inch diameter(Optional) 8-inch o.c. in 4-inch lap One or SBS-SA, APP- W-22 max. 24-inch spans attached Elastobase or Elastobase Poly with poly tin caps with 11 ga. annular and 8-inch o.c. in .. more SBS-SA, SA, SBS-TA or -52.5 6-inch o.c. with 8d common top surface ring shank nails three, equally spaced, SBS-TA or APP-TA APP-TA nails staggered center rows Min. 19/32-inch plywood at Elastobase, Elastobase Poly, Polyglass OMG Flat Bottom Plates (square) with Roofgrip #14, 12-inch o.c. in 4-inch (Optional) One or W-23 max. 24-inch spans attached G2 Base, CertainTeed Glasbase, Dekfast Hex with Dekfast lap and 12-inch o.c. in more BP -AA, SBS-AA, SBS- -52.5 6-inch o.c. with 8d common Firestone MB Base, JM Perma-Ply 28, #14 or TruFast MP-3 with two, equally spaced, SBS-AA, SBS-TA TA, APP-TA nails Tamko Glass Base or GAFGLAS #75 TruFast HD staggered center rows or APP-TA Min. 19/32-inch plywood at OMG Flat Bottom Plates (square) with Roofgrip #14, 12-inch o.c. in 4-inch One or more SBS- SBS-SA, APP- W-24 max. 24 inch spans attached Elastobase or Elastobase Poly with poly Dekfast Hex with Dekfast lap and all inch o.c. in SA, SBS-TA or SA, SBS-TA or -52.5 6-inch o.c, with Bid common top surface #14 or TruFast MP-3 with two, equally spaced, APP-TA APP-TA nails TruFast HD staggered center rows Min. 19/32-inch plywood at max. 24-inch spans attached Elastobase, Elastobase Poly, Polyglass 32 ga., 1-5/8-inch diameter 8-inch o.c. in 4-inch lap (Optional) One or W-25 4-inch o.c. with 8d common G2 Base, CertainTeed Glasbase, tin caps with 11 ga. annular and 8-inch o.c. in more BP -AA, SBS-AA, SBS- 60.0 nails or 6-inch o.c. with #8 Firestone MB Base, JM Perma-Ply 28, ring shank nails three, equally spaced, SBS-AA, SBS-TA TA, APP-TA Tamko Glass Base or GAFGLAS #75 staggered center rows or APP TA screws Min. 19/32-inch plywood at 8-inch o.c. in 4-inch lap max. 24-inch spans attached Elastobase or Elastobase Poly with poly 32 ga., 1-5/8-inch diameter and 8-inch o.cin . (Optional) One or SBS-SA, APP- W-26 4-inch o.c. with 8d common top surface tin caps with 11 ga, annular three, equally spaced, more SBS-SA, SA, SBS-TA or -60.0 nails or 6-inch o.c. with #8 ring shank nails staggered center rows SBS-TA or APP-TA APP-TA screws Min. 19/32-inch plywood at n o.c. in 4-inch (Optional) One or max. 24-inch spans attached OMG Flat Bottom Plates d inch in lap and lap more BP -AA, SBS-AA, SBS W-27 4-inch o.c. with 8d common Elastobase or Elastobase Poly (square) with Roofgrip #12 all spaced, two, equally spaced, SBS-AA, SBS-TA TA, APP-TA -60.0 nails or 6-inch o.c. with #8 staggered center rows or APP-TA screws Min. 19/32-inch plywood at 12-inch o.c. in 4-inch max. 24-inch spans attached Elastobase or Elastobase Poly with poly OMG Flat Bottom Plates lap and inch in One or more SBS- SBS-SA, APP- W-28 4-inch o.c. with Sd common top surface (square) with Roofgrip #12 two, equally spaced, , SA, SBS-TA or SA, SBS-TA or -60.0 nails or 6-inch o.c. with #8 staggered center rows APP-TA APP-TA screws Min. 19/32-inch plywood at Elastobase or Elastobase Poly with poly 32 ga., 1-5/8-inch diameter 4-inch o.in 4-inch lap c. and 4-inch o.c. in four, (Optional) One or SBS-SA, APP- W-29 max. 24-inch spans attached top surface tin caps with 11 ga, annular equally spaced, more SBS-SA, SA, SBS-TA or -97.5 6-inch o.c. with #8 screws ring shank nails. staggered center rows SBS-TA or APP-TA APP-TA Exterior Research and Design, LLC. d/b/a Trinity IERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 8 of 30 i TABLE 3E: WOOD DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Roof Deck Base Sheet Roof Cover MDP (psf) Base Fasteners Attach Ply Cap No. Min. 19/32-inch plywood at 32 ga., 1-5/8-inch diameter 6-inch o.c. in 4-inch lap and 6-inch o.c. in four, (Optional) One or more BP -AA, SBS-AA, SBS- W-30 max. 24-inch spans attached Elastobase or Elastobase Poly tin caps with 11 ga. annular equally spaced, SBS-AA, SBS-TA TA, APP-TA -112.5 6-inch o.c. with #8 screws ring shank nails . staggered center rows or APP-TA 32 ga., inch diameter .. 6-inch o.c. in 4-inch lap (Optional) One or more SBS-SA (no Min. 19/32-inch plywood at Elastobase or Elastobase Poly with poly tin caps with 11 ga, annular with and 6-inch o.c. in four, Elastoflex SA V SBS-SA, APP- W-31 max. 24-inch spans attached top surface ring shank nails. Note: Tin equally spaced, Base or Elastoflex SA, SBS-TA or -112.5 6-inch o.c. with #8 screws caps are to be primed with staggered center rows SA V FR Base), APP-TA PG100 or ASTM D41 primer. SBS-TA or APP-TA TABLE 1F: WOOD DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE F: NON -INSULATED, BONDED ROOF COVER Roof Cover System No. Deck Primer MDP (psf) ]oint Treatment Base Ply Cap Min. 19/32-inch plywood at W-32 max. 24-inch spans attached 6- (Optional) PG100 None SBS-SA (Optional) SBS-SA, SBS-SA, APP-SA, -90.0 inch o.c. with 8d ring shank SBS-TA or APP-TA SBS-TA or APP-TA nails Min. 15/32-inch plywood at Plywood joints are covered with 4-inch Elastoflex SA V (Optional) SBS-SA, SBS-SA, APP-SA, W-33 max. 24-inch spans attached 6- (Optional) PG100 wide strips of Elastoflex SA V Plus, rolled Base or Elastoflex SBS TA or APP-TA SBS-TA or APP-TA -97.5 inch o.c. with #12 screws into place to create continuous bond. SA V FR Base Min. 15/32-inch plywood at Plywood joints are covered with 4-inch Elastoflex SA V Plus (Optional) SBS-SA, SBS-SA, APP-SA, W-34 max. 24-inch spans attached 6- (Optional) PG100 wide strips of Elastoflex SA V Plus, rolled or Elastoflex SA V SBS-TA or APP-TA SBS-TA or APP-TA -135.0 inch o.c. with #12 screws into place to create continuous bond. Plus FR Exterior Research and Design, LLC. d/b/a TrinityJERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 9 of 30 TABLE 2A: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System Base Insulation Layer Top Insulation Layer Roof Cover MDP No. Roof Deck Type Fasteners Attach Type Attach Base Ply Cap (psf) Min. 22 ga., type B, Min. 1.5-inch Dekfast Hex with Dekfast #14, Trufast Min. 0.75-inch (Optional if (Optional if using AA Base) One or SBS-AA, SC-1. Grade 33 steel or ACFoam II, ENRGY MP-3 with Trufast HD 1 per 2 z FescoBoard or min. HA using AA Ply) more BP -AA, SBS- SBS-TA, -45.0* min. psi 3, Shield or or OMG 3-inch Galv ft inch Structodek BP -AA, SBS-AA AA, SBS-TA or APP-TA structrrualual concrete Polytherm Plate with OMD HD HHD D Fiberboard APP-TA Min. 22 ga., type B, Min. 2-inch Dekfast Hex with Dekfast #14, Trufast Min. 0.75-inch (Optional if (Optional if using AA Base) One or SBS-AA, SC-2. Grade 33 steel or ACFoam II, ENRGY MP-3 with Trufast HD 1 per 4 FescoBoard min. HA using AA Ply) more BP -AA, SBS- SBS-TA, -45.0* min. 2,500 psi 3, H-Shield or or OMG 3-inch Galy ftz 0.5-inch Structodek BP -AA, SBS-AA AA, SBS-TA or APP-TA structrual concrete Polytherm Plate with OMD HD HD Fiberboard APP-TA Min. 22 ga., type B, Min. 1.5-inch Dekfast Hex with Min. 0.75-inch (Optional if (Optional if using AA Base) One or SBS AA, SC-3. Grade 33 steel or ENRGY 3, H-Shield Dekfast #14 or 1 per z FescoBoard or min. HA using AA PI 9 Y) more BP -AA, SBS- SBS-TA, -90.0 min. 2,500 psi or Polytherm TruFast MP-3 with 1.33 ft 0.5-inch Structodek BP -AA SBS-AA AA, SBS-TA or APP-TA structrual concrete TruFast HD HD Fiberboard APP-TA Min. 22 ga., type B, Min. 1.5-inch Dekfast Hex with Min. 0.75-inch BP -AA, SBS-AA One or more SBS-SA, SC-4. Grade 33 steel or ENRGY 3 H-Shield Dekfast #14 or 1 per z FescoBoard or min. HA (Top surface layers, SBS-SA, APP SA, -90.0 min. 2,500 psi ' or Polytherm TruFast MP-3 with 1.33 ft 0.5-inch Structodek primed with SBS-TA or APP-TA SBS-TA or structrual concrete TruFast HD HD Fiberboard PG100 primer) APP-TA TABLE 2B: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System Base Insulation Top Insulation Layer Roof Cover MDP s (P Type Fasteners Attach Base Ply Cap No. Roof Deck Layer (Optional) (Optional if using Min. 22 ga., type B, Grade Min. 0.5-inch OMG 3-inch Galvalume 1 per (Optional if using AA Base) One or SBS-AA, SC-5. 33 steel or min. 2,500 psi One or more layers, SECUROCK Gypsum- Steel Plate with OMG #14 1ft AA Ply) BP -AA, more BP -AA, SBS-TA, -75.0 structrual concrete any combination, Fiber Roof Board HD .78 SBS-AA SBS-AA, SBS-TA APP-TA loose laid or APP-TA Min. 0.5-inch Structodek HD Dekfast Galvalume Steel (Optional if using Min. 22 ga., type B, Grade One or more layers, Fiberboard or min. Hex with Dekfast #12 (steel 1 per (Optional if using AA Base) One or SBS-AA, SC-6. 33 steel or min. 2,500 psi any combination, 0.25-inch DensDeck, only) or #14 or TruFast MP- 1.33 ftz AA Ply) BP -AA, more BP -AA, SBS-TA, -82.5 structrual concrete loose laid DensDeck Prime or 3 with TruFast DP (steel SBS-AA SBS-AA, SBS-TA APP-TA SECUROCK Gypsum- only) or HD or APP-TA Fiber Roof Board (Optional) Dekfast Galvalume Steel (Optional) One SBS-AA, Min. 22 ga., type B, Grade One or more layers, Min. 1.5-inch ENRGY Hex with Dekfast #12 (steel 1 per or more SBS-AA, SBS-TA, SC-7. 33 steel or min. 2,500 psi 3, H-Shield or only) or #14 or TruFast MP- 1.33 ftz SBS-SA SBS-TA, SBS-SA SBS-SA, -82.5 structrual concrete any combination, Polytherm 3 with TruFast DP (steel or APP-TA APP-TA, loose laid only) or HD APP-SA Exterior Research and Design, LLC. d/b/a TrinityjERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 10 of 30 QOTRINITYIERD TABLE 2C: STEEL OR CONCRETE DECKS — NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER SYSTEM TYPE D: PRELIMINARILY ATTACHED INSULATION, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER NOTE: INSULATION IS OPTIONAL FOR RECOVER APPLICATIONS System Insulation Layer(s) Base Sheet Roof Cover MDP No. Roof Deck Type Attach Base Fasteners Attach Ply Cap (P s Min. 22 ga., type B, One or more Elastobase, Elastobase OMG Flat Bottom Plates (square) with Roofgrip 12-inch o.c. in 4-inch la and P (Optional) One ( P ) SBS-AA, SC-8. Grade 33 steel or layers, any Prelim. Attached Poly or JM Perma-Ply Dekfast Hex with #14,Dekfast 18-inch stag in two, equally spaced, staggered center or more BP -AA, SBS-AA, SBS-TA SBS-TA, -45.0 * min. 2,500 psi structrual concrete combination 28 Dekfast or TruFast rows or APP-TA APP-TA h T HD MP-3 with TruFast HD Elastobase, Elastobase Min. 22 ga., type B, One or more Poly, Polyglass G2 Base, CertainTeed OMG Flat Bottom Plates (square) with Roofgrip 12-inch o.c. in 4-inch la P and (Optional) One ( P ) SBS-AA, SC-9. Grade 33 steel or layers, any Prelim. Attached Glasbase, Firestone #14, Dekfast Hex with 12-inch stag in two, equally spaced, staggered center or more BP -AA, SBS-TA SBS-TA, -52.5 min. 2,500 psi structrual concrete combination MB Base, JM Perma- Dekfast #14 or TruFast rows , or APP-TA or APP- APP-TA Ply 28, Tamko Glass MP-3 with TruFast HD Base or GAFGLAS #75 Min. 22 ga., type B, One or more Elastobase or OMG Flat Bottom Plates (square) with Roofgrip 12-inch o.c. in 4-inch la and P One or more SBS-SA, SC-10. Grade 33 steel or layers, any Prelim. Attached Elastobase Poly with #14, Dekfast Hex with spaced, stag in two, equally spaced, staggered center SBS-SA, SBS-TA APP-SA, A-52.5 SBS TA or min. 2,500 psi structrual concrete combination poly top surface Dekfast or TruFast rows or APP-TA APP-TA h T HD MP-3 with TruFast HD Min. 22 ga., type B, Grade 33 or One or more Prelim. Elastobase or Plates OMG Flat Bottom P 12-inch o.c. in 4-inch lap and 12-inch stag in two, equally (Optional) One or more BP -AA, SBS AA, SC-11. steel min. psi layers, any combination Attached Elastobase Poly (square) with Roofgrip #12 (steel only) or #14 spaced, staggered center S-AAAPP-, SBS-TA SBS-TA, APP-TA -60.0 structrual concrete structrual rows or or APP-TA Min. 22 ga., type B, Grade 33 steel or One or more Prelim. Elastobase or OMG Flat Bottom Plates 12-inch o.c. in 4-inch lap and 12-inch o.c. in two, equally One or more SBS-SA, APP SA, SC-12. min. psi layers, any Attached Elastobase Poly with (square) with Roofgrip staggered center SBS-SA, SBS-TA or -60.0 structrual structrual concrete combination poly top surface #12 (steel only) or #14 rowsspaced, or APP-TA APP TA Min. 22 ga., type B, Grade 80 steel or One or more Prelim. Dekfast isofast IF-2.375- 12-inch stag in the 5-inch (Optional) APP- SBS TA, -82.5 SC-13. min. 2,500 psi layers, any Attached Polyflex Plates with Dekfast wide, heat -welded side lap TA APP-TA structrual concrete combination #1 #15 HS Min. 22 ga., type B, Grade 80 steel or One or more Prelim. Trufast 2.4 in. Barbed 12-inch o.c. in the 6-inch (Optional) APP- SBS-TA, -82.5 SC-14. min. 2,500 psi layers, any Attached Polybond or Polyflex Seam Plates with Trufast wide, heat -welded side lap TA APP-TA structrual concrete combination EHD Fasteners Min. 22 ga., type B, Dekfast Hex with Dekfast 12-inch o.c. in the 4-inch lap (Optional) BP- SBS-AA, SC-15. Grade 33 steel or One or more layers, any Prelim. Polybond, Polyflex or #14 or OMG Flat Bottom and 18-inch stag in two, AA, SBS-AA, SBS-TA, -112.5 min. 2,500 psi Attached Elastoshield Plates with OMG Roofgrip equally spaced, staggered SBS-TA or APP APP-TA structrual concrete combination #14 center rows TA Exterior Research and Design, LLC. d/b/a Trinity IERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 11 of 30 u TABLE 3A-1: CONCRETE DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System Base Insulation Layer Top Insulation Layer Roof Cover MDP No. Deck Primer Type Attach Type Attach Base Ply Cap (Psf) SELF -ADHERING SYSTEMS WITH BASE INSULATION AND OPTIONAL TOP INSULATION OF THE SAME TYPE: (Optional) One or SBS-SA, APP- C-1 Concrete (Optional) Min. 1.5-inch H-Shield or Multi- D-IS (Optional) additional D-IS SBS-SA more SBS-SA, SA, SBS-TA or -67.5 pG100 Max FA3 layers(s) of base insulation SBS-TA or APP-TA APP-TA (Optional) One or SBS-SA, APP- C-2 Concrete (Optional) Min. 1.5 inch ACFoam II or D-IS (Optional) additional D-IS SBS-SA more SBS-SA, SA, SBS-TA or -135.0 pG100 ENRGY 3 layers(s) of base insulation SBS-TA or APP-TA APP-TA C-3 Concrete None Min. 1.5 inch, min. 1.5 pcf EPS D-IS (Optional) additional layers D-IS SBS-SA (Optional) One or more SBS-SA, SBS-SA, APP- SA, SBS-TA or -157.5 insulation board of base insulation SBS-TA or APP-TA APP-TA C-4 Concrete None Min. 1.5-inch, min. 2.0 pcf EPS OB500 (Optional) additional layers OB500 SBS-SA (Optional) One or more SBS-SA, SBS-SA, APP- SA, SBS-TA or -120.0 insulation board of base insulation SBS-TA or APP-TA APP-TA (Optional) additional (Optional) One or SBS-SA, APP- C-5 Concrete None Min. 1.5-inch ENRGY 3 OB500 layers(s) of base insulation OB500 SBS-SA more SBS-SA, SA, SBS-TA or -127.5 SBS-TA or APP-TA APP-TA C-6 Concrete None Min. 1.5-inch ACFoam II, or H- OB500 (Optional) additional OB500 SBS-SA (Optional) One or more SBS-SA, SBS-SA, APP- SA, SBS-TA or -150.0 Shield layers(s) of base insulation SBS-TA or APP-TA APP-TA Min. 1.5-inch ACFoam II, (Optional) additional (Optional) One or SBS-SA, APP- C-7 Concrete None ENRGY 3, H-Shield or Multi -Max M-OSFA layers(s) of base insulation M-OSFA SBS-SA more SBS-SA, SA, SBS-TA or -232.5 FA3 SBS-TA or APP-TA APP-TA C-8 Concrete None Min. 1.5-inch, min. 2.0 pcf EPS CR-20 (Optional) additional layers CR-20 SBS-SA (Optional) One or more SBS-SA, SBS-SA, APP- SA, SBS-TA or -240.0 insulation board of base insulation SBS-TA or APP-TA APP-TA Min. 1.5-inch ACFoam II, (Optional) One or SBS-SA, APP- C-9 Concrete None ACFoam III, ENRGY 3, H-Shield, CR-20 (Optional) additional CR-20 SBS-SA more SBS-SA, SA, SBS-TA or -270.0 H-Shield CG , Multi -Max FA3, or layers(s) of base insulation SBS-TA or APP-TA APP-TA ISO 95+ GL C-10 Concrete None Min. 2-inch ACFoam II or H- OB Classic (Optional) additional OB Classic SBS-SA (Optional) One or more SBS-SA, SBS-SA, APP- SA, SBS-TA or -270.0 Shield layers(s) of base insulation SBS-TA or APP-TA APP-TA Min. 1.5-inch ACFoam II, (Optional) additional (Optional) One or SBS-SA, APP- C-11 Concrete PG100 ACFoam III, ENRGY 3, H-Shield, HA layers(s) of base insulation HA SBS-SA more SBS-SA, SA, SBS-TA or -480.0 H-Shield CG or Multi -Max FA3 SBS-TA or APP-TA APP-TA SELF -ADHERING SYSTEMS WITH BASE INSULATION AND COVERBOARD: Min. 0.25-inch SECUROCK (Optional) One or SBS-SA, APP- C-12 Concrete None Min. 1.5-inch Multi -Max FA3 D-IS Gypsum -Fiber Roof Board D-IS SBS-SA more SBS-SA, SA, SBS-TA or -67.5 SBS-TA or APP-TA APP-TA Min. 1.5-inch, min. 2.0 pcf Min. inch DensDeck, (Optional) One or SBS-SA, APP- C-13 Concrete None ASTM C578 Expanded D-IS DensDeck eck Prime D-IS SBS-SA more SBS-SA, SA, SBS-TA or -120.0 Polystyrene SBS-TA or APP-TA APP-TA Exterior Research and Design, LLC. d/b/a Trinity IERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 12 of 30 TABLE 3A-1: CONCRETE DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System Base Insulation Layer Top Insulation Layer Roof Cover MOP No. Deck Primer Type Attach Type Attach Base Ply Cap (psf) Min. 2-inch ACFoam II, ENRGY- Min. 0.25-inch SECUROCK (Optional) One or SBS-SA, APP- C-14 Concrete None 3 or H-Shield D-IS Gypsum -Fiber Roof Board D-IS SBS-SA more SBS-SA, SA, SBS-TA or -247.5 SBS-TA or APP-TA APP-TA Min. 0.25-inch DensDeck, (Optional) One or SBS-SA, APP- C-15 Concrete None Min. 1.5-inch ENRGY 3 OB500 DensDeck Prime OB500 SBS-SA more SBS-SA, SA, SBS-TA or -127.5 SBS-TA or APP-TA APP-TA Min. 1.5-inch ACFoam II, H- Min. 0.25-inch DensDeck, (Optional) One or SBS-SA, APP- C-16 Concrete None Shield or ISO 95+GL OB500 DensDeck Prime OB500 SBS-SA more SBS-SA, SA, SBS-TA or -150.0 SBS-TA or APP-TA APP-TA Min. 2-inch ACFoam II, ENRGY- n. Min. 0.25-inch SECUROCK (Optional) One or SBS-SA, APP- C-17 Concrete None 3 H-Shield OB500 Gypsum -Fiber Roof Board OB500 SBS-SA more SBS-SA, SA, SBS-TA or -247.5 SBS-TA or APP-TA APP-TA Min. 1.5-inch ACFoam II, Min. 0.25-inch SECUROCK (Optional) One or SBS-SA, APP- C-18 Concrete None ENRGY 3, H-Shield or Multi -Max M-OSFA Gypsum -Fiber Roof Board M-OSFA SBS-SA more SBS-SA, SA, SBS-TA or -232.5 FA3 SBS-TA or APP-TA APP-TA Min. 2-inch ACFoam II, ENRGY- Min. 0.25-inch SECUROCK (Optional) One or SBS-SA, APP- C-19 Concrete None 3 or H-Shield M-OSFA Gypsum -Fiber Roof Board M-OSFA SBS-SA more SBS-SA, SA, SBS TA or -247.5 SBS-TA or APP-TA APP-TA Min. 1.5-inch, min. 2.0 pcf Min. 0.25-inch DensDeck, (Optional) One or SBS-SA, APP- C-20 Concrete None ASTM C578 Expanded CR-20 DensDeck Prime CR-20 SBS-SA more SBS-SA, SA, SBS-TA or -240.0 Polystyrene SBS-TA or APP-TA APP-TA Min. 2-inch ACFoam IV, min. 1.5-inch Ultra -Max or Multi -Max Min. 0m-Fibernch (Optional) One or SBS-SA, APP- C-21 Concrete None FA-3, min. 1.3-inch ACFoam III CR-20 Roof Board Gypsum -Fiber Roof Board CR-20 SBS-SA more SBS-SA, SA, SBS-TA or -240.0 or min. 1.0-inch ISO 95+GL, H- SBS-TA or APP-TA APP-TA Shield, H-Shield CG or ENRGY 3 Min. 2-inch ACFoam II, ENRGY- Min. 0.25-inch SECUROCK (Optional) One or SBS-SA, APP- C-22 Concrete None 3 or H-Shield CR-20 Gypsum -Fiber Roof Board CR-20 SBS-SA more SBS-SA, SA, SBS-TA or -247.5 SBS-TA or APP-TA APP-TA Min. 2-inch ACFoam II or H- Min. 0.25-inch SECUROCK (Optional) One or SBS-SA, APP- C-23 Concrete None Shield OB Classic Gypsum -Fiber Roof Board OB Classic SBS-SA more SBS-SA, SA, SBS-TA or -350.0 SBS-TA or APP-TA APP-TA Min. 1.5-inch ACFoam II, Min. 0.25-inch SECUROCK (Optional) One or SBS-SA, APP- C-24 Concrete PG100 ACFoam III, ENRGY 3, H-Shield, HA Gypsum -Fiber Roof Board HA SBS-SA more SBS-SA, SA, SBS-TA or -350.0 H-Shield CG or Multi -Max FA3 SBS-TA or APP-TA APP-TA Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 13 of 30 TABLE 3A-1 (Continued): CONCRETE DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System Base Insulation Layer Top Insulation Layer Roof Cover MDP No. Deck I Primer Type Attach Type Attach Base Ply Cap (psf) ASPHALT AND/oR TORCH APPLIED SYSTEMS: C-25 Concrete None Min. 2-inch ACFoam II or D-IS Min. 0.25-inch SECUROCK Gypsum- D-IS BP -AA, SBS-AA (Optional) One or SBS-AA -225.0 H-Shield Fiber Roof Board more BP -AA, SBS-AA C-26 Concrete None Min. 2-inch ACFoam II or D-IS Min. 0.25-inch SECUROCK Gypsum- D-IS APP-TA (Optional) One or APP-TA -232.5 H-Shield Fiber Roof Board more APP-TA C-27 Concrete None Min. 2-inch ACFoam II or OB500 Min. 0.25-inch SECUROCK Gypsum- OB500 BP -AA, SBS-AA (Optional) One or SBS-AA -225.0 H-Shield Fiber Roof Board more BP -AA, SBS-AA C-28 Concrete None Min. 2-inch ACFoam II or OB500 Min. 0.25-inch SECUROCK Gypsum- OB500 APP-TA (Optional) One or APP-TA -232.5 H-Shield Fiber Roof Board more APP-TA C-29 Concrete None Min. 2-inch ACFoam II or M-OSFA Min. 0.25-inch SECUROCK Gypsum- M-OSFA BP -AA, SBS-AA (Optional) One or SBS-AA -225.0 H-Shield Fiber Roof Board more BP -AA, SBS-AA C-30 Concrete None Min. 2-inch ACFoam II or M-OSFA Min. 25-inch 0. SECUROCK Gypsum- M-OSFA APP-TA (Optional) One or APP-TA -232.5 H-Shield Fiber Roof Board more APP-TA Min. 2-inch ACFoam IV, min. 1.5-inch Ultra -Max or Multi -Max FA-3, min. 1.3- Min. 0.25-inch (Optional) One or C-31 Concrete None inch ACFoam III or min. CR-20 SECUROCK Gypsum- CR-20 BP -AA, SBS-AA more BP -AA, SBS-AA SBS-AA -225.0 1.0-inch ISO 95+GL, H- Fiber Roof Board Shield, H-Shield CG or ENRGY 3 Min. 2-inch ACFoam IV, min. 1.5-inch Ultra -Max or Multi -Max FA-3, min. 1.3- Min. 0.25-inch (Optional) One or C-32 Concrete None inch ACFoam III or min. CR-20 SECUROCK Gypsum- CR-20 APP-TA more APP-TA APP-TA -232.5 1.0-inch ISO 95+GL, H- Fiber Roof Board Shield, H-Shield CG or ENRGY 3 C-33 Concrete None (Optional) Min. ch OB Classic Min. 0.25-inch SECUROCK Gypsum- OB Classic BP -AA, SBS-AA (Optional) One SBS-AA -225.0 hield ACFoam II or H SShiel Fiber Roof Board more BP -AA, SBS-AA C-34 Concrete None (Optional) Min. 2-inch OB Classic Min. 25-inch 0. SECUROCK Gypsum- OB Classic APP-TA (Optional) One or APP-TA -232.5 ACFoam II or H-Shield Fiber Roof Board more APP-TA Min. 1.5-inch ACFoam II, Min. 0.25-inch C-35 Concrete PG100 ACFoam III, ENRGY 3, H- Shield, H-Shield CG or HA SECUROCKGypsum- HA BP -AA, SBS-AA (Optional) One or more BP -AA, SBS-AA 585-AA -225.0 Multi -Max FA3 Fiber RoofoofBoard Exterior Research and Design, LLC. d/b/a Trinity IERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 14 of 30 TABLE 3A-1 (Continued): CONCRETE DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System Base Insulation Layer Top Insulation Layer Roof Cover MDP No. Deck Primer Type Attach Type Attach Base Ply Cap (psf) ASPHALT AND/oR TORCH APPLIED SYSTEMS: Min. 1.5-inch ACFoam II, Min. 0.25-inch C-36 Concrete PG100 ACFoam III, ENRGY 31 H- HA SECUROCK Gypsum- HA APP-TA (Optional) One or APP-TA APP-TA -232.5 Shield, H-Shield CG or Fiber Roof Board more Multi -Max FA3 (Optional if using AA (Optional if using AA C-37 Concrete PG100 Min. 0.75-inch FescoBoard HA None N/A Ply) One or more BP- Base) One or more BP -AA, SBS-AA, SBS- SBS-AA, SBS- TA, APP-TA -277 5 AA, SBS-AA TA or APP-TA Min. 1.5-inch ACFoam II, (Optional if using AA (Optional if using AA C-38 Concrete PG100 ACFoam III, ENRGY 3, H- HA Min. 0.75-inch Fesco HA Ply) One or more BP- Base) One or more SBS-AA, SBS- -290.0 Shield, H-Shield CG or Board AA, SBS-AA BP -AA, SBS-AA, SBS- TA, APP-TA Multi -Max FA3 TA or APP-TA (Optional if using AA (Optional if using AA C-39 Concrete PG100 Min. 0.5-inch Structodek HA None N/A Ply) One or more BP- Base) One or more SBS-AA, SBS- -285.0 HD Fiberboard AA, SBS-AA BP -AA, SBS-AA, SBS- TA, APP-TA TA or APP-TA Min. 1.5-inch ACFoam II, Min. 0.5-in (Optional if using AA (Optional if using AA C-40 Concrete PG100 ACFoam III, ENRGY 3, H- Shield, H-Shield CG or HA HD H HA Ply) One or more BP- Base) One or more BP -AA, SBS-AA, SBS- SBS-AA, SBS- TA, APP-TA -460.0 Multi -Max FA3 FiberbStructoarddek Fiberboard AA, SBS-AA TA or APP-TA Min. 1.5-inch ACFoam II, (Optional if using AA (Optional if using AA Concrete PG100 ACFoam ACFoam III, ENRGY 3, H- HA Min. 0.25-inch HA Ply) One or more BP- Base) One or more SBS-AA, SBS- -480.0 Shield, H-Shield CG or DensDeck Prime AA SBS-AA BP -AA, SBS-AA, SBS- TA, APP-TA Multi -Max FA3 , TA or APP-TA AA (Optional if using AA (Optional if using AA C-42 Concrete PG100 Min. 0.25-inch DensDeck HA None N/A Oneor Ply) One or more Base) One or more SBS-AA, SBS- -510.0 Prime AA, SBS-AA BP -AA, SBS-AA, SBS- TA, APP-TA TA or APP-TA Exterior Research and Design, LLC. d/b/a Trinity IERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 15 of 30 TABLE 3A-2: CONCRETE DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE A-1: BONDED TEMP ROOF, BONDED INSULATION, BONDED ROOF COVER ste Temp Base Insulation Layer Top Insulation Layer Roof Cover MOP Type Attach Type Attach Base Ply Cap myNo. Deck Prime Roof (Psi Min. 1.5-inch, min. 2.0 pcf (Optional if using polyisocyanurate base (Optional) C-43 Conc PG100 Elastoflex ASTM C578 Expanded Polystyrene or Min. 1.5-inch D-IS insulation) Min. inch D-IS SBS-SA One more SBS-SA, APP- SA, SBS-TA or -60.0 SA V Plus ACFoam II, ENRGY-3, H-Shield or DensDeck Prime or SBS-SS A, SBS- APP-TA Gypsum -Fiber TA or APP TA or Multi -Max FA3 Roof Bo Roof Board (Optional if using Elastoflex SA P or Min. 1.5-inch, min. 2.0 pcf polyisocyanurate base (Optional) SBS-SA, APP- C-44 Conc PG100 Polyglass ASTM C578 Expanded D-IS insulation) Min. 0.25-inch D-IS SBS-SA One or more SA, SBS-TA or -75.0 Base Polystyrene or Min. 1.5-inch DensDeck Prime or SBS-SA, SBS- APP-TA ACFoam II or ENRGY 3 SECUROCK Gypsum -Fiber TA or APP-TA (torched) Roof Board Min. 1.5-inch, min. 2.0 pcf (Optional if using ASTM C578 Expanded polyisocyanurate base (Optional) SBS-SA, APP- C-45 Conc PG100 Elastoflex Polystyrene or Min. 1.5-inch CR-20 insulation) Min. 0.25-inch CR-20 SBS-SA One or more SA, SBS-TA or -60.0 SA V Plus ACFoam II, ACFoam III, ENRGY DensDeck Prime or SBS-SA, SBS- APP-TA 3, H-Shield, H-Shield CG, Multi- SECUROCK Gypsum -Fiber TA or APP-TA Max FA3 or ISO 95+GL Roof Board Min. 1.5-inch, min. 2.0 pcf (Optional if using Polyglass ASTM C578 Expanded polyisocyanurate base (Optional) SBS-SA, APP- C-46 Conc PG100 Base, Polystyrene or Min. 1.5-inch CR-20 insulation) Min. 0.25-inch CR-20 SBS-SA One or more SA, SBS-TA or -75.0 (torched) ACFoam II, ACFoam III, ENRGY DensDeck Prime or SBS-SA, SBS- APP-TA 3, H-Shield, H-Shield CG, Multi- SECUROCK Gypsum -Fiber TA or APP-TA Max FA3 or ISO 95+GL Roof Board Min. 1.5-inch, min. 2.0 pcf Min. 0.25-inch DensDeck, (Optional) SBS-SA, APP- C-47 Conc PG100 Elastoflex SA P ASTM C578 Expanded CR-20 DensDeck Prime or SECUROCK Gypsum -Fiber CR-20 SBS-SA One or more SBS-SA, SBS- SA, SBS-TA or -240.0 Polystyrene Roof Board TA or APP-TA APP-TA Min. 1.5-inch ACFoam II, (Optional) SBS-SA, APP- C-48 Conc PG100 Elastoflex ACFoam III, ENRGY 31 H-Shield, CR-20 (Optional) Additional layers CR-20 SBS-SA One or more SA, SBS-TA or -250.0 SA P H-Shield CG, Multi -Max FA3 or of base insulation SBS-SA, SBS- APP-TA ISO 95+GL TA or APP-TA Min. 0.5-inch Temple HD6 Min. 1.5-inch ACFoam II, or Structodek HD (Optional) SBS-SA, APP- C-49 Conc PG100 Elastoflex ACFoam III, ENRGY 3, H-Shield, CR-20 Fiberboard or min. 0.25- CR-20 SBS-SA One or more SA, SBS-TA or -270.0 SA P H-Shield CG, Multi -Max FA3 or inch DensDeck, DensDeck SBS-SA, SBS- APP-TA ISO 95+GL Prime or SECUROCK TA or APP-TA Gypsum -Fiber Roof Board Elastoflex (Optional if SA V Vent, Min. 0.25-inch DensDeck or (Optional if using AA SA V Vent Min. 1.5-inch ACFoam II, DensDeck Prime, min. 0.5- using AA Base) One or SBS-AA, SBS- C-50 Conc PG100 FR or SA V ENRGY 3, H-Shield, ISO 95+ HA inch Structodek HD HA Ply) BP -AA, more BP -AA, TA, APP-TA -280.0 Plus GL, Multi -Max FA3 or Polytherm Fiberboard or min. 0.75- SBS-AA SBS- SBS-AA, SBS- followed by inch Fesco Board TA or APP-TA APP-TA Exterior Research and Design, LLC. d/b/a TrinityjERD Evaluation Report P9290.02.08-RB for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 16 of 30 Q0TrvN1TYjERD TABLE 3B: CONCRETE DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE F: NON -INSULATED, BONDED BASE SHEET, BONDED ROOF COVER Roof Cover System No. Deck Primer MDP (psf) Base Ply Cap C-51 Concrete PG100 Elastoflex SA V Vent or SA V (Optional) SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -280.0 Vent FR C-52 Concrete PG100 SBS-SA (Optional) SBS-SA, SBS-TA or SBS-SA, APP-SA, SBS-TA or APP-TA -315.0 APP-TA BP -AA (Optional if using asphalt f uing asphalt applied SSBS-AA, C-53 Concrete PG100 Base) BP -'AA SBS-TA or SBS-AA, SBS-TA, APP-TA -622.5 applied Ply) APP-TA Exterior Research and Design, LLC. d/b/a Trinity IERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 17 of 30 TABLE 4A: LIGHTWEIGHT CONCRETE DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Roof Deck Base Insulation Layer Coverboard Roof Cover System y (See Note 1, Page 1) MDP (psf) No. Struct. LWC Type Attach Type Attach Base Ply Cap Deck SELF -ADHERING SYSTEMS WITH BASE INSULATION AND OPTIONAL TOP INSULATION OF THE SAME TYPE: Min. 200 psi, Min. 1.5-inch, min. 2.0 pcf ASTM (Optional) Additional (Optoinal) One or more SBS- SBS-SA, APP- LWC-1 Concrete min 2-inch C578 expanded polystyrene OB500 layers of base OB500 SBS-SA SA, SBS-TA or SA, SBS-TA -120.0 Elastizell insulation APP-TA or APP-TA Min. 200 psi, Min. 1.5-inch ACFoam II, ENRGY (Optional) Additional (Optoinal) One or more SBS- SBS-SA, APP- LWC-2 Concrete min 2-inch 3, ISO 95+ GL or H-Shield OB500 layers of base OB500 SBS-SA SA, SBS-TA or SA, SBS-TA -225.0 Elastizell insulation APP-TA or APP-TA Min. 1.5-inch ACFoam II, (Optoinal) One Min. 200 psi, ACFoam III, ENRGY 3, ISO 95+ (Optional) Additional or more SBS- SBS-SA, APP- LWC-3 Concrete min. 2-inch GL, H-Shield, H-Shield CG, Multi- CR-20 layers of base CR-20 SBS-SA SA, SBS-TA or SA, SBS-TA -180.0 Elastizell Max FA3 or min. 2.0 pcf ASTM insulation APP-TA or APP-TA C578 expanded polystyrene Min. 200 psi, Min. 1.5-inch ACFoam II, ACFoam III, ENRGY 3, ISO 95+ (Optional) Additional (Optoinal) One SBS-SA, APP- LWC-4 Concrete min. 2-inch Celcore or GL, H-Shield, H-Shield CG, Multi- CR-20 layers of base CR-20 SBS-SA or more SBS- SA, SBS-TA or SA, SBS-TA -222.5 Mearlcrete Max FA3 or min. 2.0 pcf ASTM insulation APP-TA or APP-TA C578 expanded polystyrene SELF -ADHERING SYSTEMS WITH BASE INSULATION AND COVERBOARD: Min. 200 psi, Min. 1.5-inch, min. 2.0 pcf ASTM Min. 0.25-inch (Optoinal) One or more SBS- SBS-SA, APP- LWC-5 Concrete min 2-inch C578 expanded polystyrene OB500 SECUROCK Gypsum- OB500 SBS-SA SA, SBS-TA or SA, -120.0 Elastizell Fiber Roof of Board APP-TA P-TA or APP-TA Min. 200 psi, Min. 1.5-inch ACFoam II, ENRGY Min. 0.25-inch (Optoinal) One or more SBS- SBS-SA, APP- LWC-6 Concrete min 2-inch 3 ISO 95+ GL or H-Shield OB500 SECUROCK Gypsum- OB500 SBS-SA SA, SBS-TA or SA, SBS-TA -225.0 Elastizell , Fiber Roof Board APP-TA or APP-TA Min. 1.5-inch ACFoam II, (Optoinal) One Min. 200 psi, ACFoam III, ENRGY 3, ISO 95+ Min. 0.25-inch or more SBS- SBS-SA, APP- LWC-7 Concrete min. 2-inch GL, H-Shield, H-Shield CG, Multi- CR-20 SECUROCK Gypsum- CR-20 SBS-SA SA, SBS-TA or SA, SBS-TA -160.0 Elastizell Max FA3 or min. 2.0 pcf ASTM Fiber Roof Board APP-TA or APP-TA C578 expanded polystyrene Min. 200 psi, Min. 1.5-inch ACFoam II, (Optoinal) One min. 2-inch ACFoam III, ENRGY 3, ISO 95+ Min. 0.25-inch or more SBS- SBS-SA, APP- LWC-8 Concrete Celcore or GL, H-Shield, H-Shield CG, Multi- CR-20 SECUROCK Gypsum- CR-20 SBS-SA SASBS-TA or SA, SBS TA 222.5 Mearlcrete Max FA3 or min. 2.0 pcf ASTM Fiber Roof Board , APP-TA or APP-TA C578 expanded polystyrene ASPHALT ANDJOR TORCH APPLIED SYSTEMS: Exterior Research and Design, LLC. d/b/a Trinity IERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 18 of 30 TABLE 4A: LIGHTWEIGHT CONCRETE DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Roof Deck Base Insulation Layer Coverboard Roof Cover System (See Note 1, Page 1) MDP (psf) No. Struct. LWC Type Attach Type Attach Base Ply Cap Deck Min. 200 psi, Min. 1.5-inch ACFoam II, ENRGY Min. 0.25-inch BP -AA, (Optional) One or more BP -AA, SBS-AA, LWC-9 Concrete min 2-inch 3, ISO 95+ GL or H-Shield OB500 SECUROCK Gypsum- OB500 SBS-AA, SBS-AA, SBS- SBS-TA, APP- -225.0 Elastizell Fiber Roof Board APP-TA TA or APP-TA TA Min. 1.5-inch ACFoam II, (Optional) One Min. 200 psi, ACFoam III, ENRGY 3, ISO 95+ Min. 0.25-inch BP -AA, or more BP -AA, SBS-AA, LWC-10 Concrete min. 2-inch GL, H-Shield, H-Shield CG, Multi- CR-20 SECUROCK Gypsum- CR-20 SBS-AA, SBS-AA, SBS- SBS-TA, APP- -180.0 Elastizell Max FA3 or min. 2.0 pcf ASTM Fiber Roof Board APP-TA TA or APP-TA TA C578 expanded polystyrene Min. 200 psi, Min. 1.5-inch ACFoam II, (Optional) One min. inch ACFoam III, ENRGY 3, ISO 95+ Min. 0.25-inch BP -AA, or more BP -AA, SBS-AA, LWC-11 Concrete Celco reor GL, H-Shield, H-Shield CG, Multi- CR-20 SECUROCK Gypsum- CR-20 SBS-AA, SBS-AA, SBS- SBS-TA, APP- -222.5 Mearlcrete Max FA3 or min. 2.0 pcf ASTM Fiber Roof Board APP-TA TA or APP-TA TA C578 expanded polystyrene TABLE 4B: LIGHTWEIGHT CONCRETE DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER Roof Deck (See Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover MDP System No. Struct LWC Type Fasts ner Attach Type Attach Type Attach Base Ply Cap. (p'f) Min. 1.5-inch Min. 22 ga., Min. 300 7-inch o.c. at (Optional) Min. Thermaroof Composite, (Optional if Type B, psi 4-inch lap and 1.5-inch (Optional if using AA SBS-AA, LWC-12 vented steel Approved GAFGLAS OMG CP.Polytherm 7-inch o.c. in ACFoam II, H- HA Composite, or min. HA using AA Base) One or SBS-TA, -45.0 at max. 5 ft cellular #75 BSF two, equally Shield, Multi- 0.5-inch Structodek Ply) BP -AA, more BP -AA, APP-TA spans LWC spaced center Max FA3 or HD Fiberboard or SBS-AA SBS-AA, SBS rows Polytherm min. 0.75-inch TA or APP-TA FescoBoard Min. 22 ga., Min. 300 7-inch o.c. at 4-inch lap and Min. 1.5-inch (Optional) SBS-SA, LWC-13 Type B, vented steel psi Approved GAFGLAS OMG CR 7-inch o.c. in , ACFoam IIH- Shield, Multi- HA None N/A SBS-SA One or more APP-SA, -45.0 at max. 5 ft cellular #75 BSF two, equally Max FA3 or SBS-SA, SBS- SBS-TA or spans LWC spaced center Polytherm TA or APP-TA APP-TA rows Exterior Research and Design, LLC. d/b/a TrinityjERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report P9290.02.08-118 for FL1654-RIO Revision 8: 12/06/2011 Appendix 1, Page 19 of 30 TABLE 4C: LIGHTWEIGHT CONCRETE DECKS - NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER Roof Deck (See Note 1, Page 1) Base Sheet (See Note A below) Roof Cover System MDP No. Structural Deck Lightweight Concrete Type Fasteners Attach Ply Cap (Psf) (See Note A) 'GENERIC' CELLULAR LIGHTWEIGHT INSULATING CONCRETE: Min. 300 psi, min. 2-inch thick cellular LWC. Note: To Min. 22 ga., type B steel qualify the LWIC under this 7-inch o.c. in a 3-inch lap (Optional) One or LWC-14 at max 5 ft spans or assembly, an OMG CR BPF B3 OMG CR BPF and 7-inch o.c. in two, more BP -AA, SBS- SBS-AA, APP-TA -45.0 structural concrete shall achieve an average equally spaced, staggered AA withdrawal of 53 Ibf when rows in the field of the sheet tested per TAS 105 or ANSI/SPRI FX-1 CELCORE CELLULAR LIGHTWEIGHT INSULATING CONCRETE: Min. 0.0179-inch 8-inch o.c. in a 3-inch lap LWC-15 Tensilform S-75 or min. 0.0205-inch Tensilform 75 Min. 200 psi, min. 2-inch B1, B2, B3 or B7 ES FM-90 or OMG CR and 16-inch o.c, in two, One or more BP- SBS-AA -37.5 at max. 5 ft spans or thick Celcore BPF equally spaced, staggered AA, SBS-AA structural concrete rows in the field of the sheet Min. 22 ga., type B steel 7-inch o.c. in a 3-inch lap LWC-16 at max 5 ft spans or Min. 200 psi, min. 2-inch Bl through B12 ES FM-90 or OMG CR and 7-inch o.c. in two, One or more BP- SBS-AA -45.0 structural concrete thick Celcore BPF equally spaced, staggered AA, SBS-AA rows in the field of the sheet Min. 26 ga., type HF steel Bl, B2, B3, B4, 9-inch o.c. in a 3-inch lap LWC-17 at max 5 ft spans or Min. 225 psi, min. 2-inch g7, B8, B10, Bll OMG CR BPF and 9-inch o.c. in two, One or more BP- SBS-AA -45.0 structural concrete thick Celcore MF or 812 equally spaced, staggered AA, SBS-AA rows in the field of the sheet Min. 22 ga., type B steel Bl, B2, 133, B4, 7-inch o.c. in a 3-inch lap LWC-18 at max 6 ft spans or Min. 225 psi, min. 2-inch 137, 88, 1310, 1331 OMG CR BPF and 14-inch o.c. in two, One or more BP- SBS-AA -45.0 structural concrete thick Celcore MF or B12 equally spaced, staggered AA, SBS-AA rows in the field of the sheet Min. 22 ga., type B steel Bl, 132, 133, 134, 9-inch o.c. in a 3-inch lap LWC-19 at max 6 ft spans or Min. 225 psi, min. 2-inch 137, B8, 1310, Bll OMG CR BPF and 9-inch o.c. in two, One or more BP- SBS-AA -45.0 structural concrete thick Celcore MF or B12 equally spaced, staggered AA, SBS-AA rows in the field of the sheet Min. 26 ga., type HF steel Min. 200 psi, min. 2-inch 9-inch o.c. in a 4-inch lap at max 5 ft spans or min. thick Celcore or min. 225 Simplex Turbo Tube- and 12-inch o.c. in two, One or more BP - SBS-AA, SBS-TA, LWC-20 22 ga., type B steel at psi, min. 2-inch thick 82 or B11 Lok equally spaced, staggered AA, SBS-AA, SBS- or APP-TA -45.0 max 6 ft spans or Celcore MF rows in the field of the sheet TA or APP-TA structural concrete Min. 26 ga., type HF steel Min. 200 psi, min. 2-inch B2 9-inch o.c. in a 4-inch lap LWC-21 at max 5 ft spans or min. 22 ga., type B steel at thick Celcore or min. 225 (with poly -film Simplex Turbo Tube- and 12-inch o.c. in two, One or more SBS- SA, SBS-TA or SBS-SA, APP-SA, -45.0 max 6 ft spans or psi, min. 2-inch thick top surface) Lok equally spaced, staggered APP TA SBS-TA or APP-TA structural concrete Celcore MF rows in the field of the sheet Exterior Research and Design, LLC. d/b/a Trinity IERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 20 of 30 QOTRINITYIERD TABLE 4C: LIGHTWEIGHT CONCRETE DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER Roof Deck (See Note 1, Page 1) Base Sheet (See Note A below) Roof Cover System MDP No. Structural Deck Lightweight Concrete Type Fasteners Attach Ply Cap (psf) (See Note A) Min. 22 ga., type B steel 9-inch o.c. in a 4-inch lap One more BP- LWC-22 at max 5 ft spans or Min. 225 psi, min. 2-inch Bl or 82 ES Twin Loc Nail and 18-inch o.c. in two, AA, SBB S-AA, SBS- SBS-AA, SBS-TA, -45.0 structural concrete thick Celcore MF equally spaced, staggered TA or APP TA or APP-TA rows in the field of the sheet Min. 22 ga., type B steel Min. 225 psi, min. 2-inch B2 9-inch o.c. in a 4-inch lap and 18-inch o.c. in two, One or more SBS- SBS-SA, APP-SA, LWC-23 at max 5 ft spans or thick Celcore MF (with poly -film ES Twin Loc-Nail equally spaced, staggered SA, SBS-TA or SBS-TA or APP-TA -45.0 structural concrete top surface) rows in the field of the sheet APP-TA Min. 22 ga., type B steel 8-inch o.c. in a 4-inch lap LWC-24 at max 5 ft spans or Min. 300 psi, min. 2-inch 82 ES FM-90 and 8-inch o.c. in three BP -AA, SBS-AA, SBS-AA, SBS-TA, -60.0 structural concrete thick Celcore MF equally spaced, staggered SBS-TA or APP-TA or APP-TA center rows Min. 22 ga., type B steel Min. 300 psi, min. 2-inch 82 8-inch o.in a 4-inch lap p and 8-inch o.c. in three One or more SBS- SBS-SA, APP-SA, LWC-25 at max 5 ft spans or thick Celcore MF (with poly -film ES FM-90 equally spaced, staggered SA, SBS-TA or SBS-TA or APP-TA -60.0 structural concrete top surface) center rows APP-TA Min. 22 ga., type B steel 7-inch o.c. in a 3-inch lap LWC-26 at max 5 ft spans or Min. 300 psi, min. 2-inch Bl through 812 ES FM-90 or OMG CR and 7-inch o.c. in two, One or more BP- SBS-AA -75.0 structural concrete thick Celcore BPF equally spaced, staggered AA, SBS-AA rows in the field of the sheet Min. 22 ga., type B steel Min. 300 psi, min. 2-inch 10-inch o.c. in a 4-inch lap and SO -inch o.c. in three (Optional) BP -AA, SBS-AA, SBS-TA, LWC-27 at max 5 ft spans or thick Celcore MF Elastobase Poly ES FM-260 equally spaced, staggered SBS TA APP-TA 90.0 structural concrete center rows or APP-, or PP -TA ELASTIZELL CELLULAR LIGHTWEIGHT INSULATING CONCRETE: Min. 0.0179-inch 7.5-inch o.c. in a 3-inch lap LWC-28 Tensilform S-75 or min. 0.0205-inch Tensilform 75 Min. 200 psi, min. 2-inch BS through B12 ES FM-90 or OMG CR and 7.5-inch o.c. in two, One or more BP - AA, SBS- SBS-AA, SBS TA, -30.0 at max. 5 ft spans or thick Elastizell Range II BPF equally spaced, staggered or APP-, TA, or PP -TA or APP-TA structural concrete rows in the field of the sheet Min. 0.0179-inch B2 7.5-inch o.c. in a 3-inch lap Tensilform S-75 or min. Min. 200 psi, min. 2-inch ES FM-90 or OMG CR and 7.5-inch o.c. in two, One or more SBS- SBS-SA, APP-SA, LWC-29 0.0205-inch Tensilform 75 thick Elastizell Range II (with poly -film BPF equally spaced, staggered SA, SBS-TA or SBS-TA or APP-TA -30.0 at max. 5 ft spans or top surface) rows in the of the sheet field APP-TA structural concrete Min. 22 a., g type B steel Min. 200 psi, min. 2-inch ES FM-90 or OMG CR 7-inch o.c. in a 3-inch lap and 7-inch o.c. in two, One ormore BP- SBS-AA, SBS-TA, LWC-30 at max 5 ft spans or thick Elastizell Range II gl through B12 BPF equally spaced, staggered S-AA, SBS- qq� SBS-AA, or APP-TA -45.0 structural concrete rows in the field of the sheet TA, or APP-TA Min. 22 ga., type B steel Min. 200 psi, min. 2-inch B2 ES FM-90 or OMG CR 7-inch o.c. in a 3-inch lap and 7-inch o.c. in two, One or more SBS- SBS-SA, APP-SA, LWC-31 at max 5 ft spans thick Elastizell Range II (with poly -film BPF equally spaced, staggered SA, SBS-TA or SBS-TA or APP-TA -45.0 structural concrete top surface) rows in the field of the sheet APP-TA Exterior Research and Design, LLC. d/b/a Trinity IERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 21 of 30 �INITYJERD TABLE 4C: LIGHTWEIGHT CONCRETE DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE E. MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER Roof Deck (See Note 1, Page 1) Base Sheet (See Note A below) Roof Cover System MDP No. Structural Deck Lightweight Concrete Type Fasteners Attach Ply Cap (Psf) (See Note A) Min. 22 ga., type B steel 9-inch o.c. in a 4-inch lap One or more BP- SBS-AA, SBS-TA, LWC-32 at max 5 ft spans or Min. 200 psi, min. 2-inch 82 or Bll Simplex Turbo Tube- and 12-inch o.c. in two, AA, SBS-AA, SBS- SBS-SA, APP-TA -45.0 structural concrete thick Elastizell Range II Lok equally spaced, staggered TA, SBS-SA, or or APP-SA rows in the field of the sheet APP-TA Min. 350 psi, min. 2-inch Min. 22 ga., type B steel thick Elastizell with Zell- 6-inch o.c. in a 4-inch lap SBS-AA, SBS-TA, LWC-33 at max 5 ft spans or Crete Fibers, supple- B2 ES Twin Loc-Nails and 6-inch o.c, in three, One or more BP- SBS-SA, APP-TA -60.0 structural concrete mentally attached with (min. 1.8-inch) equally spaced, staggered AA or SBS-AA or APP-SA Roofgrip #21 and 3-inch rows in the field of the sheet plates at 1 per 8 ft2 Min. 350 psi, min. 2-inch Min. 22 ga., type B steel thick Elastizell with Zell- B2 6-inch o.c. in a 4-inch lap Crete Fibers, supple- ES Twin Loc-Nails and 6-inch o.c. in three, SBS-SA, SBS-TA SBS-SA, APP-SA , -60.0 LWC-34 at max 5 ft spans or mentally attached with (with poly -film (min. 1.8-inch) equally spaced, staggered or APP-TA SBS-TA or APP-TA structural concrete Roofgrip #21 and 3-inch top surface) rows in the field of the sheet plates at 1 per 8 ft2 MEARLCRETE CELLULAR LIGHTWEIGHT INSULATING CONCRETE: 7.5-inch o.c. in a 3-inch lap LWC-35 Min. 24 ga., type B steel at max 5 ft spans or Min. 200 psi, min. 2-inch Bl through B12 ES FM-90 or OMG CR and 10-inch o.c. in two, One or more BP- SBS-AA -30.0 thick Mearlcrete BPF equally spaced, staggered AA, SBS-AA structural concrete rows in the field of the sheet Min. 22 ga., type B steel Min. 300 psi, min. 2-inch ES FM-90 or OMG CR 7-inch o.c. in a 4-inch lap and 7-inch o.c. in two, One or more BP- AA, SBS-AA, SBS- SBS-AA, SBS-TA, -45.0 LWC-36 at max 5 ft spans or thick Mearlcrete Bl, B2 or B12 BPF equally spaced, staggered TA, or APP-TA or APP-TA structural concrete rows in the field of the sheet Min. 22 ga., type B steel Min. 300 psi, min. 2-inch 62 ES FM-90 or OMG CR p 7-inch o.c. in a 4-inch la and 7-inch o.c. in two, One or more SBS- SBS-SA, APP-SA, LWC-37 at max 5 ft spans or thick Mearlcrete (with poly -film BPF equally spaced, staggered SA, SBS-TA or SBS-TA or APP-TA -45.0 structural concrete top surface) rows in the field of the sheet APP-TA Min. 22 ga., type B steel Min. 300 psi, min. 2-inch B1, B2, B3, 84, 9-inch o.c. in a 4-inch lap and 9-inch o.c. in two, One or more BP - SBS-TA, LWC-38 at max ft spans or thick Mearlcrete B7, B8 or Bll Simplex Base-Lok equally spaced, staggered AA,SBS-AA, SBS- or APP-TA -45.0 structural concrete a rows in the field of the sheet TA, or APP-, TA, or APP-TA Min. 22 ga., type B steel Min. 300 psi, min. 2-inch 62 9-inch o.c. in a 4-inch lap and 9-inch o.c. in two, One or more SBS- SBS-SA, APP-SA, LWC-39 at max 5 ft spans or thick Mearlcrete (with poly -film Simplex Base-Lok equally spaced, staggered SA, SBS-TA or SBS-TA or APP-TA -45.0 structural concrete top surface) rows in the field of the sheet APP-TA Min. 22 ga., type B steel Min. 300 psi, min. 2-inch Simplex Turbo Tube- 9-inch o.c, in a 4-inch lap and 12-inch o.c. in two, One or more BP- AA, SBS-AA, SBS- SBS-AA, SBS-TA, SBS-SA, APP-TA -45.0 LWC-40 at max 5 ft spans or thick Mearlcrete B2 or Bll Lok equally spaced, staggered TA, SBS-SA, or or APP-SA structural concrete rows in the field of the sheet APP-TA Min. 22 ga., type B steel Min. 300 psi, min. 2-inch Bl, B2, B3, 137 or ES FM-90 or OMG CR 7-inch o.c. in a 4-inch lap and 7-inch o.c. in two, One or more 13P- AA, SBS- SBS-AA, SBS-TA, -52.5 LWC-41 at max 5 ft spans or thick Mearlcrete BS1 BPF equally spaced, staggered TA, or PP - or APP-TA , or APP-TA structural concrete rows in the field of the sheet Exterior Research and Design, LLC, d/b/a TrinitylERD tvaluation Keport F 91'JU.ut.Uts-Kt3 for mi654-Kiu Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 22 of 30 TABLE 4C: LIGHTWEIGHT CONCRETE DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER Roof Deck (See Note 1, Page 1) Base Sheet (See Note A below) Roof Cover System MDP No. Structural Deck Lightweight Concrete Type Fasteners Attach Ply Cap (Psf) (See Note A) Min. 22 ga., type B steel Min. 300 psi, min. 2-inch 82 ES FM-90 or OMG CR 7-inch o.c. in a 4-inch lap and 7-inch o.c. in two, One or more SBS- SBS-SA, APP-SA, LWC 42 at max 5 ft spans or thick Mearlcrete (with poly -film (w BPF equally spaced, staggered SA, SBS-TA or SBS-TA or APP-TA -52.5 structural concrete top surface) rows in the field of the sheet APP TA Min. 22 ga., type B steel Min. 300 psi, min. 2-inch 9-inch o.c. in a 4-inch lap and 12-inch o.c. in two, One or more BP- SBS-AA, SBS-TA, LWC-43 at max 5 ft spans or thick Mearlcrete B1, B2, B3 or B4 Simplex Base-Lok equally spaced, staggered AA, SBS-AA, SBS- or APP-TA -52.5 structural concrete rows in the field of the sheet TA, or APP-TA Min. 22 ga., type B steel Min. 300 psi, min. 2-inch 82 9-inch o.in a 4-inch lap p and inch o.c. in two, One orB more SBS- SBS-SA, P LWC-44 at max 5 ft spans or p thick Mearlcrete (with poly -film Simplex Base-Lok equally spaced, staggered equally SA, SBS-TA or r P-T SBS-TA or APP-TA -52.5 structural concrete top surface) rows in the field of the sheet APP-TA A. Base Sheets options are coded as follows: ➢ Bl: Polyglass G2 Base; ➢ B2: Elastobase or Elastobase Poly; ➢ B3: GAFGLAS #75; ➢ B4: Stratavent Eliminator Venting Base Sheet (Nailable); ➢ B5: GAFGLAS Ply 4; ➢ B6: GAFGLAS FlexPly 6; ➢ B7: JM Perma Ply No. 28; ➢ B8: JM Vensulation; ➢ B9: JM GlasPly IV, ➢ B10: JM GlasPly Premier; ➢ Bll: Tamko Glass -Base; ➢ B12: Tamko Vapor -Chan Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report P9290.02.08-118 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 23 of 30 TABLE SA: CEMENTITIOUS WOOD FIBER DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System Base Insulation Layer Top Insulation Layer Roof Cover No. Deck MDP ps Type Attach Type Attach Base Ply Cap Min. 0.25-inch Min. 1.5-inch DensDeck, DensDeck (Optional) One or CWF-1 Min. 2.5-inch Tectum ACFoam II, ISO 95+GL, H-Shield, D-IS or OB500 Prime, SECUROCK Gypsum -Fiber Roof D-IS or OB500 BP -AA, SBS- more BP -AA, SBS- SBS-AA, SBS- -45.0 Plank or Tectum LS Plank Polytherm, Board or min. 0.5- AA AA, SBS-TA or APP- TA, APP-TA ENRGY-3 inch Structodek HD TA Fiberboard Min. 1.5-inch Min. 0.25-inch ACFoam II, ISO DensDeck, DensDeck SBS-TA, (Optional) One or SBS-TA, SBS- CWF-2 Min. 2.5-inch Tectum 95+GL, H-Shield, D-IS or OB500 Prime, SECUROCK D-IS or OB500 SBS-SA or more SBS-TA, SBS- SA, APP-TA, -45.0 Plank or Tectum LS Plank Polytherm, Gypsum -Fiber Roof APP-TA SA or APP-TA APP-SA ENRGY-3 Board Min. 0.25-inch Min. 1.5-inch DensDeck, DensDeck (Optional) One or CWF-3 Min. 2.5-inch Tectum ACFoam II, ISO 95+GL, H-Shield, CR-20 Prime, SECUROCK Gypsum -Fiber Roof CR-20 BP -AA, SBS- more BP -AA, SBS- SBS-AA, SBS- -52.5 Plank or Tectum LS Plank Polytherm, Board or min. 0.5- AA AA, SBS-TA or APP- TA, APP-TA ENRGY-3 inch Structodek HD TA Fiberboard Min. 1.5-inch Min. 0.25-inch ACFoam II, ISO DensDeck, DensDeck SBS-TA, (Optional) One or SBS-TA, SBS- CWF-4 Min. 2.5-inch Tectum 95+GL, H-Shield, CR-20 Prime, SECUROCK CR-20 SBS-SA or more SBS-TA, SBS- SA, APP-TA, -52.5 Plank or Tectum LS Plank Polytherm, Gypsum -Fiber Roof APP-TA SA or APP-TA APP-SA ENRGY-3 Board Exterior Research and Design, LLC. d/b/a TrinityjERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 24 of 30 Q0TP'.1N1TYjERD TABLE SB: CEMENTITIOUS WOOD FIBER DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System Anchor Sheet Base Insulation Top Insulation Roof Cover MDP No. Roof Deck Type Fastener Attach Type Attach Type Attach Base Ply Cap (Psf) 9-inch o.c. in Min. 1.5-inch Min. 0.25-inch DensDeck, DensDeck (Optional) Min. 2.5-inch Elastobase, ES 4-inch lap and 12-inch o.c. in ACFoam II, ACFoam III, Prime, SECUROCK One or SBS-AA, CWF-5 Tectum Plank or Elastobase Poly, Polyglass Inuldek two, equally IS095+GL, H- HA Gypsum -Fiber Roof Board, Min. 0.75-inch HA BP -AA, SBS-AA more BP- AA, SBS- SBS-TA, -30.0 * Tectum LS Plank G2 Base Loc-Nail spaced, Shield, ENRGY 3, FescoBoard or min. AA, SBS-TA APP-TA staggered Polytherm or 0.5-inch Structodek or APP-TA center rows Multi -Max FA3, HD Fiberboard 9-inch o.c. in Min. 1.5-inch Elastobase, 4-inch lap and ACFoam II, Min. 0.25-inch (Optional) SBS-TA, Min. 2.5-inch Elastobase ES 12-inch o.c. in ACFoam III, DensDeck, DensDeck SBS-TA, One or SBS-SA, CWF-6 Tectum Plank or Poly, Polyglass Inuldek two, equally IS095+GL, H- HA Prime, SECUROCK HA SBS-SA or more SBS- APP-TA, -30.0* Tectum LS Plank Loc-Nail spaced, Shield, ENRGY 3, Gypsum -Fiber Roof APP-TA TA, SBS-SA APP SA G2 Base staggered Polytherm or Board or APP-TA center rows Multi -Max FA3, 9-inch o.c. in Min. 1.5-inch Min. 0.25-inch DensDeck, DensDeck (Optional) Elastobase, Simplex 4-inch lap and ACFoam II, Prime, SECUROCK One or SBS-AA, Min. 2.5-inch Elastobase Base-Lok 18-inch o.c. in ACFoam III, HA Gypsum -Fiber Roof yp HA BP -AA, more BP- SBS-TA, -45.0* CWF-7 Tectum Plank or Poly, Polyglass or ES two, equally IS095+GL, H- Board, Min. 0.75-inch SBS-AA AA, SBS- APP-TA Tectum LS Plank G2 Base Twin Loc- spaced, Shield, ENRGY 3, FescoBoard or min. AA, SBS-TA Nail staggered Polytherm or inch Structodek or APP-TA center rows Multi -Max FA3, HD Fiberboard HD 9-inch o.c. in Min. 1.5-inch Elastobase, Simplex 4-inch lap and ACFoam II, Min. 0.25-inch (Optional) SBS-TA, Min. 2.5-inch Base-Lok 18-inch o.c. in ACFoam III, DensDeck, DensDeck SBS-TA, One or SBS-SA, CWF-8 Tectum Plank or Elastobase or ES two, equally IS095+GL, H- HA Prime, SECUROCK HA SBS-SA or more SBS- ' APP-TA, -45.0* m TectuLS Plank Poly, Polyglass Twin Loc- spaced, Shield, ENRGY 3, Gypsum -Fiber Roof APP-TA TA, SBS-SA APP SA G2 Base Nail staggered Polytherm or Board or APP-TA center rows Multi -Max FA3, TABLE SC: CEMENTITIOUS WOOD FIBER DECKS — NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System Base Insulation Layer Top Insulation Layer Roof Cover MDP (psf) No. Roof Deck Type Fasteners Attach Type Attach Base Ply Cap OMG N.T.B. Plate (Optional if (Optional if using Min. 2.5-inch Tectum Min. 2-inch H-' with N.T.B. Magnum Min. 0.5-inch using AA Ply) AA Base) One or SBS-AA, CWF-9 Plank or Tectum LS Shield or or TruFast TL 3 in. 1 per 4 ftZ Structodek HD HA AA, SBS- more BP -AA, SBS- SBS-TA, -45.0* Plank Polytherm Plate with TL Fiberboard AA SBS-TA or APP-TA Fastener APP-TA Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 25 of 30 TABLE SD: CEMENTITIOUS WOOD FIBER DECKS — NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System Roof Deck Base Insulation Top Insulation Layer Roof Cover MDP (psf) Type Fasteners Attach Base Ply Cap No. Layer (Optional) One or Min. 0.25-inch DensDeck, (Optional if using Min. 2.5-inch more layers, any DensDeck Prime or SECUROCK ES Twin Loc-Nails (min. : (Optional if AA Base) One or SBS-AA, CWF-10 Tectum Plank or combination, loose Gypsum -Fiber Roof Board or 1-inch embedment) 1 per 2 ft using AA Ply) more BP -AA, SBS- SBS-TA, -45.0* Tectum LS Plank laid min. 0.5-inch Structodek HD BP -AAA SBS-AA AA, SBS-TA or APP-TA Fiberboard I I I I APP-TA TABLE SE: CEMENTITIOUS WOOD FIBER DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Base Sheet Roof Cover No. Roof Deck MDP (psf) Base Fasteners Attach Ply Cap Min. 2.5-inch 9-inch o.c. in 4-inch lap and 12- (Optional) One or CWF-11 Tectum Plank or Elastobase, Elastobase Poly, Polyglass G2 ES Inuldek Loc-Nail inch o.c. in two, equally spaced, more BP -AA, SBS-AA, SBS- -30.0* Tectum LS Plank Base staggered center rows SBS-AA, SBS-TA TA, APP-TA or APP-TA Min. 2.5-inch Elastobase, Elastobase Poly, Polyglass G2 Simplex Base-Lok or ES 9-inch o.c. in 4-inch lap and 18- (Optional) One or more BP -AA, SBS-AA, SBS- CWF-12 Tectum Plank or Base Twin Loc-Nails inch o.c. in two, equally spaced, SBS-AA, SBS-TA TA, APP-TA -45.0 * Tectum LS Plank staggered center rows or APP-TA Exterior Research and Design, LLC. d/b/a TrinityjERD Evaluation Report P9290.02.08-118 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 26 of 30 `mil TRINITY I ERD TABLE GA: GYPSUM DECKS — REROOF (Tear -Off) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System Base Insulation Layer Top Insulation Layer Roof Cover Deck MDP (psf) Type Attach Type Attach Base Ply Cap No. Min. 1.5-inch (Optional) additional Existing, sound poured ACFoam II, ENRGY 3 layers(s) of base (Optional) One or SBS-SA, APP- G-1 gypsum or gypsum plank or H-Shield or min. 2.0 pcf, ASTM C578 OB500 insulation and/or min. 0.25-inch OB500 SBS-SA more SBS-SA, SBS- SA, -112.5 deck expanded SECUROCK Gypsum- TA or APP-TA PP -TA or APP-TA polystyrene Fiber Roof Board (Optional) additional Existing, sound poured Min. 1.5-inch layers(s) of base (Optional) One or SBS-SA, APP- G-2 gypsum or gypsum plank ACFoam II, ENRGY 3, H-Shield or Multi- M-OSFA insulation and/or min. 0.25-inch M-OSFA SBS-SA more SBS-SA, SBS- SA, SBS-TA -202.5 deck Max FA3 SECUROCK Gypsum - TA or APP-TA or APP-TA Fiber Roof Board (Optional) additional Existing, sound poured Min. 1.5-inch, min. layers of base insulation and/or (Optional) One or SBS-SA, APP- G-3 gypsum or gypsum plank 2.0 pcf EPS insulation CR-20 min. 0.25-inch CR-20 SBS-SA more SBS-SA, SBS- SA, SBS-TA -240.0 deck board SECUROCK Gypsum - TA or APP-TA or APP-TA Fiber Roof Board Min. 0.25-inch (Optional if (Optional if using AA Existing, sound poured DensDeck, DensDeck using AA Base) One or more SBS-AA, SBS- G-4 gypsum or gypsum plank Prime or SECUROCK CR-20 None N/A Ply) BP -AA, BP -AA, SBS-AA, TA, APP-TA -245.0 deck Gypsum -Fiber Roof SBS-AA SBS-TA or APP-TA Board Min. 1.5-inch (Optional) additional sound poured ACFoam II, ACFoam layersExisting, of base insula nsulatioon and/or (Optional) One or SBS-SA, APP- G-5 gypsum or gypsum plank III, ENRGY 3, H- CR-20 min. ch CR-20 SBS-SA more SBS-SA, SBS- SA, SBS-TA -2S7.5 deck Shield, H-Shield CG ROCK Gypsum - SECUROCK Gypsum - TA or APP-TA or APP-TA or Multi -Max FA3 Fiber Roof Board Exterior Research and Design, LLC. d/b/a TrinityjERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 27 of 30 TABLE 6B: GYPSUM DECKS — REROOF (Tear -Off) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER Anchor Sheet Base Insulation Top Insulation Roof Cover System No. Roof Deck yp Type Attach Type e yp Attach T Type Attach Base Ply Cap MDP (psf) s 9-inch o.c. in Min. 1.5-inch Min. 0.25-inch DensDeck, DensDeck (Optional) Existing, sound Elastobase, 4-inch lap and 18-inch o.c. in ACFoam II, ACFoam III, Prime, SECUROCK One or SBS-AA, G-6 poured gypsum or p Elastobase ES FM-45 two, equally ISO95+GL, H- HA Gypsum -Fiber Roof HA BP -AA, more BP- SBS-TA, -30.0* gypsum plank Poly, Polyglass or FM-60 spaced, Shield, ENRGY 3, Board, Min. 0.75-inch SBS-AA AA, SBS- APP-TA deck G2 Base staggered Polytherm or FescoBoard or min. AA, SBS-TA center rows Multi -Max FA3, 0.5-inch Structodek or APP-TA HD Fiberboard 9-inch o.c, in Min. 1.5-inch Min. 0.25-inch DensDeck, DensDeck (Optional) Existing, sound Elastobase, ES FM-75 4-inch lap and 18-inch o.c. in ACFoam II, ACFoam III, Prime, SECUROCK One or SBS-AA, G-7 poured gypsum or Elastobase or FM-90 two, equally ISO95+GL, H- HA Gypsum -Fiber Roof HA BP -AA, more BP- SBS-TA, -45.0* gypsum plank Poly, Polyglass or Twin spaced, Shield, ENRGY 3, Board, Min. 0.75-inch SBS-AA AA, SBS- APP-TA deck G2 Base Loc-Nails staggered Polytherm or FescoBoard or min. AA, SBS-TA center rows Multi -Max FA3, 0.5-inch Structodek or APP-TA HD Fiberboard TABLE 6C: GYPSUM DECKS — REROOF (Tear -Off) or RECOVER SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System Roof Deck Base Insulation Top Insulation Layer Roof Cover MDP (psf) Type Fasteners Attach Base Ply Cap No. Layer Existing sound (Optional) One or Min. 0.25-inch DensDeck, (Optional if using G-8 poured gypsum more layers, any DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board or ES Twin Loc-Nails (min. 1 per 2 ftz (Optional if using AA Ply) AA Base) One or more BP -AA, SBS- SBS-AA, SBS-TA, -45.0 * or gypsum plank combination, loose min. 0.5-inch Structodek HD 1-inch embedment) BP -AA, SBS-AA AA, SBS-TA or APP-TA deck laid Fiberboard APP-TA TABLE 61): GYPSUM DECKS — REROOF (Tear -Off) SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Base Sheet Roof Cover No. Roof Deck Base Fasteners Attach Ply Cap MDP (psf) Existing sound Elastobase, Elastobase Poly, Polyglass G2 9-inch o.c. in 4-inch lap and 18- (Optional) One or more BP -AA, SBS-AA, SBS- * G-9 poured gypsum or Base ES FM-45 or FM-60 inch o.c. in two, equally spaced, SBS-AA, SBS-TA TA, APP-TA -30.0 gypsum plank deck staggered center rows or APP-TA G-10 Existing sound poured gypsum or Elastobase, Elastobase Poly, Polyglass G2 ES FM-75 or FM-90 or 9-inch o.c. in 4-inch lap and 18- inch o.c. in two, equally spaced, (Optional) One or more BP -AA, SBS-AA, SBS- -45.0 gypsum plank deck Base Twin Loc-Nails staggered center rows SBS-AA, SBS-TA TA, APP-TA or APP-TA Exterior Research and Design, LLC. d/b/a TrinityjERD Evaluation Report P9290.02.08-118 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 28 of 30 Q0TPnuN1TYjER1r, TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System Base Insulation Layer Top Insulation Layer Roof Cover MDP fl No. Substrate Type Attach Type Attach Base Ply Cap (Ps (Optional) additional Existing layers(s) of base (Optional) One or SBS-SA, APP- R-1 asphaltic Min. 1.5-inch Multi -Max FA3 D-IS insulation and/or.min. D-IS SBS-SA more SBS-SA, SA, SBS-TA or -67.5 roof 0.25-inch SECUROCK SBS-TA or APP-TA APP-TA Gypsum -Fiber Roof Board (Optional) additional Existing Min. 1.5-inch ACFoam II or layers(s) of base (Optional) One or SBS-SA, APP- R-2 asphaltic ENRGY 3 or min. 2.0 pcf EPS D-IS insulation and/or min. D-IS SBS-SA more SBS-SA, SA, SBS-TA or -90.0 roof insulation board 0.25-inch SECUROCK SBS-TA or APP-TA APP-TA Gypsum -Fiber Roof Board (Optional) additional Existing layers of base insulation (Optional) One or SBS-SA, APP- R-3 asphaltic Min. 1.5-inch, min. 2.0 pcf EPS OB500 and/or min. 0.25-inch OB500 SBS-SA more SBS-SA, SA, SBS-TA or -120.0 roof insulation board SECUROCK Gypsum -Fiber SBS-TA or APP-TA APP-TA Roof Board (Optional) additional Existing layers(s) of base (Optional) One or SBS-SA, APP- R-4 asphaltic Min. inch ACFoam II, OB500 insulation and/or min. OB500 SBS-SA more SBS-SA, SA, SBS-TA or -127.5 roof ENRGYY 33 or H-Shield 0.25-inch SECUROCK SBS-TA or APP-TA APP-TA Gypsum -Fiber Roof Board (Optional) additional Existing Min. 1.5-inch ACFoam II, layers(s) of base (Optional) One or SBS-SA, APP- R-5 asphaltic ENRGY 3, H-Shield or Multi -Max M-OSFA insulation and/or min. M-OSFA SBS-SA more SBS-SA, SA, SBS-TA or -157.5 roof FA3 0.25-inch SECUROCK SBS-TA or APP-TA APP-TA Gypsum -Fiber Roof Board Min. 2-inch ACFoam IV, min. 1.5-inch Ultra -Max or Multi -Max (Optional) additional Existing FA-3, min. 1.3-inch ACFoam III layers(s) of base (Optional) One or SBS-SA, APP- R-6 asphaltic or min. 1.0-inch ISO 95+GL, H- CR-20 insulation and/or min. CR-20 SBS-SA more SBS-SA, SA, SBS-TA or -240.0 roof Shield, H-Shield CG or ENRGY 3 0.25-inch SECUROCK SBS-TA or APP-TA APP-TA or min. 2.0 pcf ASTM C578 Gypsum -Fiber Roof Board expanded polystyrene (Optional) additional Existing Min. 2-inch ACFoam II, ENRGY- layers(s) of base (Optional) One or SBS-SA, APP- R-7 asphaltic 3 or ld or min. 2.0 pcf CR-20 insulation and/or min. CR-20 SBS-SA more SBS-SA, SA, SBS-TA or -247.5 roof C578expanded ASTM 578 0.25-inch SECUROCK SBS-TA or APP-TA APP-TA polystyrene Gypsum -Fiber Roof Board Min. 0.25-inch DensDeck, BP -AA, SBS- (Optional) One or Existing DensDeck Prime or D-IS AA, SBS-TA, more BP -AA, SBS- SBS-AA, SBS- -67.5 R-8 asphaltic Min. 1.5-inch Multi -Max FA3 D-IS SECUROCK Gypsum -Fiber SBS-SA, AA, SBS-TAor TA, orAPP-TA roof Roof Board APP-TA APP-TA Min. 0.25-inch DensDeck, BP -AA, SBS- (Optional) One or Existing Min. 1.5-inch ACFoam II or ACFoam DensDeck Prime or D-IS AA, SBS-TA, more BP -AA, SBS- SBS-AA, SBS- _g0.0 R-9 asphaltic ENRGY 3 or min. 2.pcf EPS D-IS SECUROCK Gypsum -Fiber SBS-SA, AA, SBS-TAor TA, or APP-TA roof insulation board Roof Board APP-TA APP-TA Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 29 of 30 �J TRIfJITY ERD TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System Base Insulation Layer Top Insulation Layer Roof Cover MDP No. Substrate Type Attach Type Attach Base Ply Cap (psf) Min. 0.25-inch DensDeck, BP -AA, SBS- (Optional) One or R 10 Existing asphaltic Min. 1.5-inch ACFoam II, ENRGY 3, H-Shield or ISO OB500 DensDeck Prime or OB500 AA, SBS-TA, more BP -AA, SBS- SBS-AA, SBS- -127.5 SECUROCK Gypsum -Fiber SBS-SA, AA, SBS-TAor TA, or APP-TA roof 95+GL Roof Board APP-TA APP-TA BP -AA, SBS- (Optional) One or R-11 Existing asphaltic Min. 1.5-inch ACFoam II, ENRGY 3, H-Shield or Multi -Max M-OSFA Min. 0.25-inch SECUROCK M-OSFA AA, SBS-TA, more BP -AA, SBS- SBS-AA, SBS- -157.5 Gypsum -Fiber Roof Board SBS-SA, AA, SBS-TAor TA, or APP-TA roof FA3 APP-TA APP-TA Min. 2-inch ACFoam IV, min. 1.5-inch Ultra -Max or Multi -Max Existing FA-3, min. 1.3-inch ACFoam III Min. 0.25-inch SECUROCK BP -AA, SBS- (Optional) One or R-12 asphaltic or min. 1.0-inch ISO 95+GL, H- CR-20 Gypsum -Fiber Roof Board CR-20 AA more BP -AA, SBS- SBS-AA -225.0 roof Shield, H-Shield CG or ENRGY 3 AA or min. 2.0 pcf ASTM C578 expanded polystyrene Min. 2-inch ACFoam IV, min. 1.5-inch Ultra -Max or Multi -Max R-13 Existing asphaltic FA-3, min. 1.3-inch ACFoam III or min. 1.0-inch ISO 95+GL, H- CR-20 Min. 0.25-inch SECUROCK CR-20 APP-TA (Optional) One or APP-TA -232.5 roof Shield, H-Shield CG or ENRGY 3 Gypsum -Fiber Roof Board more APP-TA - or min. 2.0 pcf ASTM C578 expanded polystyrene TABLE7B: RECOVER APPLICATIONS SYSTEM TYPE F: NON -INSULATED, BONDED BASE SHEET, BONDED ROOF COVER Roof Cover System No. Deck Primer MDP (psf) Base Ply Cap Existing BP -AA (Optional if using asphalt using asphalt applied R-14 asphaltic roof PG100 applied Ply) Base) BP -If AA SSBS-AA, SBS TAor SBS-AA, SBS-TA, APP-TA -45.0 APP-TA Exterior Research and Design, LLC, d/b/a TrinityjERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 30 of 30 `�J TRINITY EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 Christian Street ER® Oxford, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT Polyglass USA, Inc. 150 Lyon Drive Fernley, NV 89408 Evaluation Report P9290.02.08-1118 FL1654-R10 Date of Issuance: 02/11/2608 Revision 8: 12/06/2011 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been designed to comply with the 2010 Florida Building Code sections noted herein. DESCRIPTION: Polyglass SBS and APP Modified Bitumen Roof Systems LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P..E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 5, plus a 30-page Appendix. Prepared by: �R���,�,n�,miri•,`. +' The facsimile seal appearing was authorized �� by Robert Nleminen, P.E. on 12/06/2011 <•; This does not serve as an electronically signed Robert I.M. Nieminen P.E. document. Signed, sealed hardcoples have been '�i°�pUa�i+ transmitted to the Product Approval Administrator and Florida Registration No. 59166, Florida DCA ANE1983 f' to the named client CERTIFICATION OF INDEPENDENCE: 1. Exterior Research & Design, LLC. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Modified Bitumen Roof Systems Compliance Statement: Polyglass SBS and APP Modified Bitumen Roof Systems, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind FM 4474 2004 1504.7 Impact FM 4470 1992 1507.11.2 Physical Properties ASTM D6163 2000 1507.11.2 Physical Properties ASTM D6164 2005 1507.11.2 Physical Properties ASTM D6222 2002 3. REFERENCES: Entity Examination Reference Date ERD (TST6049) Physical Properties P10490.10.08-2 10/30/2008 ERD (TST6049) FM 4470/4474 P13760.09.09 09/10/2009 ERD (TST6049) FM 4470/4474 P13770.09.09 09/10/2009 ERD (TST6049) FM 4470/4474 P30540.11.09-R1 11/30/2009 ERD (TST6049) FM 4470/4474 P30550.12.09 12/02/2009 ERD (TST6049) Physical Properties P33960.12.10 12/30/2010 ERD (TST6049) FM 4470/4474 P33970 12/02/2009 FM Approvals (TST1867) FM 4470 2W7A7.AM 08/04/1994 FM Approvals (TST1867) FM 4470 OD3A3.AM 04/04/1997 FM Approvals (TST1867) FM 4470 2DOAO.AM 12/23/1998 FM Approvals (TST1867) FM 4470 2D5A9.AM 06/22/1999 FM Approvals (TST1867) FM 4470 3006646 01/04/2000 FM Approvals (TST1867) FM 4470 3001334 01/25/2000 FM Approvals (TST1867) FM 4470 3001334 02/15/2000 FM Approvals (TST1867) FM 4470 3000857 01/12/2000 FM Approvals (TST1867) FM 4470 3004091 01/12/2000 FM Approvals (TST1867) FM 4470 3006115 05/02/2001 FM Approvals (TST1867) FM 4470 3012321 07/29/2002 FM Approvals (TST1867) FM 4470 3014692 08/05/2003 FM Approvals (TST1867) FM 4470 3014751 08/27/2003 FM Approvals (TST1867) FM 4470 3007170 01/13/2004 FM Approvals (TST1867) FM 4470 3019317 06/30/2004 FM Approvals (TST1867) FM 4470 3020703 07/30/2004 FM Approvals (TST1867) FM 4470/4474 3018332 01/31/2006 . FM Approvals (TST1867) FM 4470/4474 3023368 03/20/2006 FM Approvals (TST1867) FM 4470/4474 3024594 05/23/2006 FM Approvals (TST1867) FM 4470/4474 3023458 07/18/2006 FM Approvals (TST1867) FM 4470/4474 3030668 09/12/2007 FM Approvals (TST1867) FM 4470/4474 3032172 06/12/2009 PRI (TST5878) Physical Properties PUSA-062-02-01 12/04/2007 PRI (TST5878) Physical Properties PUSA-061-02-02 01/28/2008 PRI (TST5878) Physical Properties PUSA-064-02-02 02/27/2008 PRI (TST5878) Physical Properties PUSA-062-02-02 12/04/2008 UL (QUA1734) Quality Control UL File R14571 Exp. 11/30/2012 Miami -Dade (CER1592) HVHZ Compliance Various NOAs Various Miami -Dade (CER1592) Proposal for Review 10-0823 10/12/2010 Exterior Research and Design, LLC. Evaluation Report'P9290.02.08-R8 Certificate of Authorization #9503 FL1654-R10 Revision 8: 12/06/2011 Page 2 of 5 i 4. PRODUCT DESCRIPTION: This Evaluation Report covers Polyglass Modified Bitumen Roof Systems installed in accordance with Polyglass USA, Inc. published installation instructions and the Limitations / Conditions of Use herein. The following Polyglass membranes make up the subject systems. Table 1: Roll -Goods for Polyglass Modified Bitumen Roof Systems Type Product Specification Reference Grade Type Base Sheets Polyglass G2 Base ASTM D4601 N/A II Modibase ASTM D4601 N/A II SBS Membranes Elastobase ASTM D6163 S I Elastoflex V ASTM D6163 S I Elastoflex SA V Base ASTM D6163, Table 2 S I Elastoflex SA V FR Base ASTM D6163, Table 2 S I Elastoflex SA V Plus ASTM D6163 S I Elastoflex SA V Plus FR ASTM D6163 S I Elastoflex SA V Vent ASTM D6163 S I Elastoflex SA V Vent FR ASTM D6163 S I Elastobase Poly ASTM D6164 S I Elastoflex S6 ASTM D6164 S I Elastoflex S6 G ASTM D6164 G I Elastoflex S6 G FR ASTM D6164 G I Polyfresko MOP ASTM D6164 S I Polyfresko MOP FR ASTM D6164 S I Elastoshield TS G ASTM D6164 S I Elastoshield TS G FR ASTM D6164 G I Elastoflex SA P ASTM D6164 G I Elastoflex SA P FR ASTM D6164 G I Polyfresko SBS SAP ASTM D6164 S I Polyfresko SBS SAP FR ASTM D6164 S I APP Membranes Polyflex ASTM D6222 S I Polyflex G ASTM D6222 G I Polyflex G FR ASTM D6222 G I Polyfresko Torch ASTM D6222 S I Polyfresko Torch FR ASTM D6222 S I Polybond ASTM D6222 S I Polybond G ASTM D6222 G I Polyflex SA P ASTM D6222 G I Polyflex SA P FR ASTM D6222 G I Polyfresko APP SAP ASTM D6222 S I Polyfresko APP SAP FR ASTM D6222 S I Polykool ASTM D6222 S I Polybianko ASTM D6222 S I Exterior Research and Design, LLC. Evaluation Report P9290.02.08-118 Certificate of Authorization #9503 FL1654-R10 Revision 8: 12/06/2011 Page 3of5 QOTRINITYIERD 5. LIMITATIONS: 5.1 This Evaluation Report is not for use in HVHZ. 5.2 Refer to a current Roofing Materials Directory for fire ratings of this product. 5.3 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply. 5.4 Unless otherwise noted in Appendix 1, roof decking and its attachment shall be specified and installed to meet project design criteria to the satisfaction of the AHJ. 5.5 For recover installations, the existing roof shall be examined in accordance with FBC 1510. 5.6 For mechanically attached insulation or membrane or strip -bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117 and FM LPDS 1-29. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3 enhancements. 5.7 For fully -adhered insulation, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems 5.8 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI FX-1. 5.9 For bonded insulation or membrane over existing substrates in a re -roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ASTM E907, FM LPDS 1-52, ANSI/SPRI IA-1 or TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.10 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the AHJ, as documented through field uplift testing in accordance with ASTM E907, FM LPDS 1-52 or TAS 124. 5.11 Metal edge attachment (exept gutters), shall be designed and installed for wind loads in accordance with FBC Chapter 16 and tested for for resistance in accordance with ANSI/SPRI ES-1 or RAS 111, except the basic wind speed shall be determined from FBC Figure 1609. 5.12 All products in the roof assembly shall have quality assurance audit in accordance with the FBC and F.A.C. Rule 9N-3. 6. INSTALLATION: 6.1 Polyglass Modified Bitumen roof systems shall be installed in accordance with Polyglass USA, Inc. published installation instructions, subject to the Limitations / Conditions of Use noted below. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. Exterior Research and Design, LLC. Evaluation Report P9290.02.08-118 Certificate of Authorization #9503 FL1654-R10 Revision 8: 12/06/2011 Page 4 of 5 PTRRINITYIEKD 6.3 Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind load performance. Refer to current Roofing Materials Directory for fire ratings associated with coating usage. ➢ PG200 Non Fibered Roof Coating or Mule -Hide 111 Non-Fibrated Roof Coating; ➢ PG300 Fibered Roof Coating or Mule -Hide 102 Fibrated Roof Coating; ➢ PG600 Non-Fibered Aluminum Roof Coating or Mule -Hide 416 Standard Non-Fibrated Aluminum Roof Coating; ➢ PG650 Fibered Aluminum Roof Coating or Mule -Hide 406 Standard Fibrated Aluminum Roof Coating; ➢ PG700 White Reflective Roof Coating; ➢ PG800 Non-Fibered Asphalt Emulsion Roof Coating or Mule -Hide 311 Emulsion Non-Fibrated; ➢ PG850 Fibered Asphalt Emulsion Roof Coating or Mule -Hide 301 Emulsion Fibrated; ➢ Polyplus 60 Premium Non-Fibered Aluminum Roof Coating or Mule -Hide 410 Premium Non-Fibrated Aluminum Roof Coating; ➢ Polyplus 65 Premium Fibered Aluminum Roof Coating or Mule -Hide 401 Premium Fibrated Aluminum Roof Coating; ➢ Polybrite 70 White Elastomeric Roof Coating. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. S. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. Rule 9N-3 QA requirements 9. QUALITY ASSURANCE ENTITY: Underwriters Laboratories - QUA1743; (314) 578-3406, k.chancellor@us.ul.com - THE 30-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report P9290.02.08-R8 Certificate of Authorization #9503 FL1654-R10 Revision 8: 12/06/2011 Page 5 of 5 APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE Table Deck Application Type Description Page 1A-1 Wood New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 4 1A-2 Wood New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 5 1B Wood New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 6 1C Wood New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 6 1D Wood New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 7 1E Wood New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 8-9 1F Wood New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 9 2A Steel or Conc. New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 10 2B Steel or Conc. New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 10 2C Steel or Conc. New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 11 3A-1 Concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 12-15 3A-2 Concrete New or Reroof (Tear -Off) A-1 Bonded Temporary Roof, Bonded Insulation, Bonded Roof Cover 16 3B Concrete New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 17 4A LWIC New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 18-19 4B LWIC New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 19 4C LWIC New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 20-23 5A CWF New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 24 5B CWF New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 25 5C CWF New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 25 5D CWF New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 26 5E CWF New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 26 6A Gypsum New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 27 6B Gypsum New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 28 6C Gypsum New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 28 6D Gypsum New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 28 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 29-30 7B Various Recover F Non -Insulated, Bonded Base Sheet, Bonded Roof Cover 30 The following notes apply to the systems outlined herein: 1. Roof decks shall be in accordance with FBC requirements to the satisfaction of the AHJ. Wind load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement: ➢ Wood: Minimum 0.75-inch penetration. ➢ Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck. ➢ Concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions. 3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, DensDeck, DensDeck Prime, DensDeck DuraGuard, SECUROCK Gypsum -Fiber Roof Board or SECUROCK Glass -Mat Roof Board that meets the QA requirements of F.A.C. Rule 9N-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC 2603.4.1 or 2603.6, when installed with the roof cover. Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 1 of 30 q0�P.,lNi-rYIERD 4. Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the base sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. 5. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published instructions. ➢ HA (HA): Full coverage at 25-30 Ibs/square. ➢ Dow Insta-Stik Roofing Adhesive (D-IS): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. ➢ Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c. ➢ OMG OlyBond 500 (013500): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. (PaceCart or SpotShot). Note: OlyBond Green may be used where OlyBond 500 is referenced. ➢ OlyBond Classic (OB Classic): Full coverage at 1 gal/square. ➢ 3M CR-20: Continuous 2.5-3.5-inch wide ribbons, 12-inch o.c. Note: TITESEfmay be used where CR-20 is referenced. ➢ Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon -applied adhesive, adhesive ribbons shall be staggered from layer -to -layer a distance of one-half the ribbon spacing. ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. S. Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocya n u rate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to `increase' the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table: ➢ Millennium One Step Foamable Adhesive (M-OSFA): MDP -157.5 psf (Min. 0.5-inch thick) ➢ OMG OlyBond 500 (013500): MDP -45.0 psf (Min. 0.5-inch thick Multi -Max FA-3) ➢ OMG OlyBond 500 (06500): MDP -187.5 psf (Min. 0.5-inch thick ISO 95+ GL) ➢ OMG OlyBond 500 (013500): MDP -315.0 psf (Min. 0.5-inch thick ENRGY 3) ➢ OMG OlyBond 500 (013500): MDP -487.5 psf (Min. 0.5-inch thick ACFoam II) ➢ 3M CR-20: MDP -117.5 psf (Min. 1.0-inch thick) 7. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. 8. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are PAS 117 and FM LPDS 1-29. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3 enhancements. 9. For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted. 10. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI FX-1. 11. For existing substrates in a bonded recover installation, the existing roof system shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the AHJ, as documented through field uplift testing in accordance with ASTM E907, FM LPDS 1-52, ANSI/SPRI IA-1 or TAS 124. 12. For Recover Applications using System Type D, the insulation is optional; however, the existing roof system shall be suitable for a recover application. Exterior Research and Design, LLC. d/b/a Trinity IERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 2 of 30 13. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications. Table 1: Polyglass Roof Covers Reference Layer Material Application BP -AA Base Polyglass G2 Base, Modibase, FBC Approved ASTM D4601, Type II HA at 20-40 (Base and Ply sheets, Asphalt -Applied) Ply FBC Approved ASTM D2178, Type IV or VI or ASTM D4601, Type II Ibs/square Base or Ply Elastobase, Elastobase Poly, Elastoflex V, Elastoflex S6 SBS-AA (SBS, Asphalt -Applied) Ca p Elastoflex S6, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, Elastoshield TS-G FR, Polyfresko HA at 20-40 Ibs/square MOP, Polyfresko MOP FR Base or Ply Elastoflex V, Elastoflex S6 SBS-TA (SBS, Torch -Applied) Cap Elastoflex V, Elastoflex S6, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, Elastoshield TS-G Torch -Applied FR, Polyfresko MOP, Polyfresko MOP FR SBS-SA Base Elastoflex SA V Base, Elastoflex SA V FR Base, Elastoflex SA V Plus, Elastoflex SA V Plus FR Self (SBS, Self -Adhering) Cap Elastoflex SA P, Elastoflex SA P FR, Polyfresko SBS SAP, Polyfresko SBS SAP FR -Adhering APP-TA Base or Ply Polyflex, Polybond Torch (APP, Torch -Applied) Cap Polyflex, Polyflex G, Polyflex G FR, Polybond, Polybond G, Polyfresko Torch, Polyfresko Torch FR -Applied APP-SA Cap Polyflex SA P, Polyflex SA P FR, Polyfresko APP SAP, Polyfresko APP SAP FR, Polykool, Polybianko Self -Adhering (APP, Self -Adhering) 14. Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind load performance. Refer to current Roofing Materials Directory for fire ratings associated with coating usage. ➢ PG200 Non Fibered Roof Coating or Mule -Hide 111 Non-Fibrated Roof Coating; ➢ PG300 Fibered Roof Coating or Mule -Hide 102 Fibrated Roof Coating; ➢ PG600 Non-Fibered Aluminum Roof Coating or Mule -Hide 416 Standard Non-Fibrated Aluminum Roof Coating; ➢ PG650 Fibered Aluminum Roof Coating or Mule -Hide 406 Standard Fibrated Aluminum Roof Coating; ➢ PG700 White Reflective Roof Coating; ➢ PG800 Non-Fibered Asphalt Emulsion Roof Coating or Mule -Hide 311 Emulsion Non-Fibrated; ➢ PG850 Fibered Asphalt Emulsion Roof Coating or Mule -Hide 301 Emulsion Fibrated; ➢ Polyplus 60 Premium Non-Fibered Aluminum Roof Coating or Mule -Hide 410 Premium Non-Fibrated Aluminum Roof Coating; ➢ Polyplus 65 Premium Fibered Aluminum Roof Coating or Mule -Hide 401 Premium Fibrated Aluminum Roof Coating; ➢ Polybrite 70 White Elastomeric Roof Coating. 15. The following represent priming requirements for gypsum -based coverboards: ➢ DensDeck and DensDeck Prime shall be field -primed with PG100 prior to self -adhering or torch -applied membrane application. No priming is required for hot -asphalt membrane applications. ➢ SECUROCK Gypsum -Fiber Roof Board or DensDeck DuraGuard do not require field priming for any membrane application. 16. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609.1.5 for determination of design wind loads. Exterior Research and Design, LLC. d/b/a Trinity IERD Evaluation Report P9290.02.08-118 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 3 of 30 TABLE 1A-1: WOOD DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System Anchor Sheet Base Insulation Top Insulation Roof Cover MDP No. Roof Deck Type Fasteners Attach Type Attach Type Attach Base Ply Cap (psf) Min. 19/32-inch Elastobase, Elastobase 32 ga., 1- 8-inch o.in c. 4-inch lap (Optional) Min. 0.25-inch DensDeck, DensDeck plywood at max. Poly, Polyglass G2 Base, CertainTeed 5/8-inch diameter tin and 8-inch FBC Approved, PrimeSECUROCK , (Optional) SBS-AA, W-1 24-inch spans Glasbase, Firestone caps with 11 o.c. in three, ASTM C1289, HA Gypsum -Fiber Roof HA BP -AA or BP -AA or SBS-TA, -52.5 attached 6-inch Base, JM Perma- ga. annular equally type II Board, Min. 0.75-inch SBS-AA SBS-AA APP-TA 8d o.c. with 8 Ply 28, Tamko Glass Ply ring shank spaced, polyiso- FescoBoard or min. common nails Base or GAFGLAS #75 nails staggered cyanurate 0.5-inch Structodek center rows HD Fiberboard Min. 19/32-inch Elastobase, Elastobase 32 ga., 1- 8-inch o.in c. 4-inch lap (Optional) (Optional) plywood at max. Poly, Polyglass G2 5/8-inch and 8-inch FBC Min. 0.25-inch One or SBS-SA, 24-inch spans Base, CertainTeed diameter tin o.c. in three, Approved, DensDeck, DensDeck more APP-SA, W-2 attached 6-inch Glasbase, Firestone caps with 11 equally ASTM C1289, HA Prime, SECUROCK HA SBS-SA SBS-SA, SBS-TA or -52.5 o.c. with 8d MB Base, JM Perma- ga. annular spaced, type II Gypsum -Fiber Roof SBS-TA or APP-TA common nails Ply 28, Tamko Glass ring shank staggered polyiso- Board APP-TA Base or GAFGLAS #75 nails center rows cyanurate Min. 19/32-inch 32 ga., 1- 8-inch o.c. in (Optional) Min. 0.25-inch plywood at max. Polyglass G2 Base, 5/8-inch 4-inch lap FBC DensDeck, DensDeck 24-inch spans CertainTeed Glasbase, diameter tin and 8-inch Approved, Prime, SECUROCK (Optional) SBS-AA, W-3 attached 4-inch Firestone MB Base, JM caps with 11 o.c. in three, ASTM C1289, HA Gypsum -Fiber Roof HA BP -AA or BP -AA or SBS-TA, -60.0 o.c. with 8d Perma-Ply 28, Tamko ga. annular equally type II Board, Min. 0.75-inch SBS-AA SBS-AA APP-TA common nails or Glass Base or ring shank i spaced, polyiso- FescoBoard or min. 6-inch o.c. with GAFGLAS #75 nails staggered cyanurate 0.5-inch Structodek #8 screws center rows HD Fiberboard Min. 19/32-inch 32 ga., 1- 8-inch o.c. in (Optional) plywood at max. Polyglass G2 Base, 5/8-inch 4-inch lap FBC Min. 0.25-inch (Optional) 24-inch spans CertainTeed Glasbase, diameter tin and 8-inch Approved, DensDeck, DensDeck One or SBS-SA, W-4 attached 4-inch Firestone MB Base, JM caps with 11 o.c. in three, ASTM C1289, HA Prime, SECUROCK HA SBS-SA more APP-SA, -60.0 o.c. with 8d Perma-Ply 28, Tamko annular equally type II Gypsum -Fiber Roof SBS-SA, SBS-TA or common nails or Glass Base orga ring shank ring spaced, polyiso- Board SBS-TA or APP-TA 6-inch o.c. with GAFGLAS #75 nails staggered cyanurate APP-TA #8 screws center rows Min. 19/32-inch 32 ga., 1- 6-inch o.c. in D-IS, plywood at max. 5/8-inch 4-inch lap Min. 2-inch OB500, CR- Min. 0.25-inch 24-inch spans diameter tin and 6-inch ACFoam II, 20 or M- DensDeck, DensDeck D-IS , (Optional) SBS-AA, W-5 attached 4-inch Elastobase or caps with 12 o.c. in four, III, H-Shield, OSFA, atop Prime or SECUROCK OB500, BP AA or BP -AA or SBS-TA, -60.0 o.c. with 8d Elastobase Poly ga. annular equally H-Shield CG, fastener Gypsum -Fiber Roof CR-20 or SBS-AA SBS-AA APP-TA common nails or ring shank spaced, Multi -Max FA3 rows, Board M-OSFA 6-inch o.c. with nails staggered or ENRGY-3 inch oc #8 screws center rows Min. 19/32-inch 32 ga., 1- 6-inch o.c. in D-IS, plywood at max. 5/8-inch 4-inch lap Min. 2-inch OB500, CR- (Optional) 24-inch spans diameter tin and 6-inch ACFoam II, 20 or M- (Optional) Additioal D-IS, One or SBS-SA, W-6 attached 4-inch Elastobase or caps with 12 o.c. in four, III, H-Shield, OSFA, atop layers of base OB500, SBS-SA more APP-SA, -60.0 o.c. with 8d Elastobase Poly ga. annular equally H-Shield CG, fastener insulation CR-20 or SBS-SA, SBS-TA or common nails or ring shank spaced, Multi -Max FA3 rows, M-OSFA SBS-TA or APP-TA 6-inch o.c. with nails staggered or ENRGY-3 inch o c APP-TA #8 screws center rows Exterior Research and Design, LLC. d/b/a Trinity IERD Evaluation Report P9290.02.08-118 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 4 of 30 TABLE 1A-2: WOOD DECKS — NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System Anchor Sheet Base Insulation Top Insulation Roof Cover MDP No. Roof Deck Type Fasteners Attach Type Attach Type Attach Base Ply Cap (psf) Elastobase, OMG Flat o.c. Min. 0.25-inch Min. 19/32-inch Elastobase Poly, Bottom Plates n 4-inch lap in 4 -inh (Optional) DensDeck, DensDeck plywood at Polyglass G2 Base, (square) with and 12-inch FBC Prime, SECUROCK max. 24-inch CertainTeed Roofgrip #14, two, Approved, Gypsum -Fiber Roof BP -AA or (Optional) SBS-AA, W-7 spans attached Glasbase, Firestone Dekfast Hex equally equally ASTM C1289, HA Board, Min. 0.75- HA SBS-AA BP -AA or SBS-TA, -52.5 6-inch o.c. with MB Base, JM Perma- with Dekfast spaced, type II inch FescoBoard or SBS-AA APP-TA 8d common Ply 28, Tamko Glass #14 or TruFast staggered polyiso- min. 0.5-inch nails Base or GAFGLAS MP-3 with center rows cyanurate Structodek HD #75 TruFast HD Fiberboard Elastobase, OMG Flat 12-inch o.c. Min. 19/32-inch Elastobase Poly, Bottom Plates in 4-inch lap (Optional) plywood at Polyglass G2 Base, (square) with and 12-inch FBC Min. 0.25-inch (Optional) SBS-SA, max. 24-inch CertainTeed Roofgrip #14, two, O.C.qu Approved, DensDeck, DensDeck One or APP-SA, W-8 spans attached Glasbase, Firestone Dekfast HexASTM 11 equally C1289, HA Prime, SECUROCK HA SBS-SA more SBS- SBS-TA or -52.5 6-inch o.c. with MB Base, JM Perma- with Dekfast spaced, type II Gypsum -Fiber Roof SA, SBS-TA APP-TA 8d common Ply 28, Tamko Glass #14 or TruFast staggered polyiso- Board or APP-TA nails Base or GAFGLAS MP-3 with center rows cyanurate #75 TruFast HD Min. 19/32-inch 12-inch o.c. Min. 0.25-inch plywood at in 4-inch lap (Optional) DensDeck, DensDeck max. 24-inch OMG Flat and 12-inch FBC Prime, SECUROCK spans attached Elastobase or Bottom Plates o.c. in two, Approved, Gypsum -Fiber Roof BP -AA or (Optional) SBS-AA, W-9 4-inch o.c. with Elastobase Poly (square) with equally ASTM C1289, HA Board, Min. 0.75- HA SBS-AA BP -AA or SBS-TA, -60.0 8d common Roofgrip #12 spaced, type II inch FescoBoard or SBS-AA APP-TA nails or 6-inch staggered polyiso- min. 0.5-inch o.c. with #8 center rows cyanurate Structodek HD screws Fiberboard Min. 19/32-inch 12-inch o.c. plywood at in 4-inch lap (Optional) max. 24-inch OMG Flat and 12-inch FBC Min. 0.25-inch (Optional) SBS-SA, spans attached Elastobase or Bottom Plates o.c. in two, Approved, DensDeck, DensDeck One or APP-SA, W-10 4-inch o.c. with Elastobase Poly (square) with equally ASTM C1289, HA Prime, SECUROCK HA SBS-SA more SBS- SBS-TA or -60.0 Sd common Roofgrip #12 spaced, type II Gypsum -Fiber Roof SA, SBS-TA APP-TA nails or 6-inch staggered polyiso- Board or APP-TA o.c. with #8 center rows cyanurate screws Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 5 of 30 i �k TABLE 1B: WOOD DECKS — NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System Base Insulation Layer Top Insulation Layer Roof Cover MOP No. Roof Deck Type Fasteners Attach Type Attach Base Ply Cap (per Min. 19/32-inch plywood Min. 1.5-inch Dekfast Hex with Min. 0.75-inch (Optional if (Optional if using AA SBS-AA, at max. 24-inch spans ENRGY 3, H- Dekfast #12 or 1 per FescoBoard or min. HA using AA Ply) Base) One or more SBS-TA, -52.5 W-11 attached 6-inch o.c. with Shield or TruFast MP-3 with 1.33 fe 0.5-inch Structodek BP -AA, SBS- BP -AA, SBS-AA, APP-TA 8d common nails Polytherm TruFast DP HD Fiberboard AA SBS-TA or APP-TA Min. 19/32-inch plywood Min. 1.5-inch Dekfast Hex with Min. 0.75-inch (Optional if (Optional if using AA SBS-AA, at max. 24-inch spans ENRGY 3, H- Dekfast #12 or 1 per FescoBoard or min. HA using AA Ply) Base) One or more SBS-TA, -60.0 W-12 attached 4-inch o.c. with Shield or TruFast MP-3 with 1.33 ftz 0.5-inch Structodek BP -AA, SBS- BP -AA, SBS-AA, APP-TA m 8d comon nails or 6- Polytherm TruFast DP HD Fiberboard AA SBS-TA or APP-TA inch with #8 screws TABLE 1C: WOOD DECKS — NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System Base Insulation Top Insulation Layer Roof Cover MDP Type Fasteners Attach Base Ply Cap No. Roof Deck Layer (ps f) Min. 0.5-inch Structodek (Optional if using Min. 19/32-inch plywood (Optional) HD Fiberboard or min. Dekfast Galvalume (Optional if AA Base) One or W-13 at max. 24-inch spans One or more layers, 0.25-inch DensDeck, Steel Hex with 1 per 1.33 ft z using Ply) more BP -AA, SBS SBS-AA, SBS- TA, APP-TA -52.5 attached 6-inch o.c. with an combination, y DensDeck Prime or Dekfast #12 DP BP -AA, SBS-AA , S AA, SBS-TA or Bd common nails loose laid SECUROCK Gypsum -Fiber APP-TA Roof Board Min. 0.5-inch Structodek (Optional if using Min. 19/32-inch plywood (Optional) HD Fiberboard or min. Dekfast Galvalume (Optional if AA Base) One or W-14 at max. 24-inch spans One or more layers, 0.25-inch DensDeck, Steel Hex with 1 per, using AA Ply) more BP -AA, SBS- SBS-AA, SBS- TA, APP-TA -67.5 attached 4-inch o.c. with an combination, Y DensDeck Prime or Dekfast #12 DP 1.33 ftZ BP -AA, SBS-AA AA, SBS-TA or 8d common nails loose laid SECUROCK Gypsum -Fiber APP-TA Roof Board Min. 0.5-inch Structodek (Optional if using Min. 19/32-inch plywood (Optional) HD Fiberboard or min. Dekfast Galvalume (Optional if AA Base) One or W-15 at max. 24-inch spans One or more layers, 0.25-inch DensDeck, Steel Hex with 1 per 1.33 ft2 using AA Ply) more BP -AA, SBS- SBS-AA, SBS- TA, APP-TA -82.5 attached 6-inch o.c. with an combination, Y DensDeck Prime or Dekfast #12 DP BP -AA, SBS-AA AA, SBS-TA or #8 screws loose laid SECUROCK Gypsum -Fiber APP-TA Roof Board Min. 19/32-inch plywood (Optional) Dekfast Galvalume Steel Hex with (Optional) One or SBS-SA, APP- W-16 at max. 24-inch spans One more layers, Min. 1.5-inch ENRGY 3, H- Dekfast #12 DP or 1 per ft 2 SBS-SA more SBS-SA, SA, SBS-TA or -82.5 attached 6-inch o.c. with combination, any coo Shield or Polytherm TruFast MP-3 with 1.33 SBS-TA or APP-TA APP-TA #8 screws loose laid TruFast DP Exterior Research and Design, LLC. d/b/a Trinity IERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 6 of 30 TABLE ID: WOOD DECKS — NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER SYSTEM TYPE D: PRELIMINARILY ATTACHED INSULATION, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Insulation Layer(s) Base Sheet Roof Cover No. Roof Deck Type Attach Base Fasteners Attach Ply Cap MDP (psf) Elastobase, Elastobase Poly, OMG Flat Bottom Min. 19/32-inch Polyglass G2 Base, Plates (square) with 12-inch o.c. in 4-inch (Optional) One or plywood at max. 24- One or more Prelim. CertainTeed Glasbase, Roofgrip #14, lap and 12-inch o.c. more BP -AA, SBS-AA, SBS- W-17 inch spans attached layers, any Attached Firestone MB Base, JM Dekfast Hex with in two, equally SBS-AA, SBS-TA TA, APP-TA -52.5 6-inch o.c. with 8d combination Perma-Ply 28, Tamko Glass Dekfast #14 or spaced, staggered or APP-TA common nails Base or GAFGLAS #75 TruFast MP-3 with center rows TruFast HD OMG Flat Bottom Min. 19/32-inch Plates (square) with 12-inch o.c. in 4-inch plywood at max. 24- One or more Prelim. Elastobase or Elastobase Roofgrip #14, lap and 12-inch o.c. One or more SBS- SBS-SA, APP- W-18 inch spans attached layers, any Attached Poly with poly top surface Dekfast Hex with in two, equally SA, SBS-TA or SA, SBS-TA or -52.5 6-inch o.c. with 8d combination Dekfast #14 or spaced, staggered APP-TA APP-TA common nails TruFast MP-3 with center rows TruFast HD Min. 19/32-inch plywood at max. 24- 12-inch o.c. in 4-inch (Optional) One or inch spans attached One or more Prelim. Elastobase or Elastobase OMG Flat Bottom lap and 12-inch o.c. more BP -AA, SBS-AA, SBS- W-19 4-inch o.c. with 8d layers, any Attached Poly Plates (square) with in two, equally SBS-AA, SBS-TA TA, APP-TA -60.0 common nails or 6- combination Roofgrip #12 spaced, staggered or APP-TA inch o.c. with #8 center rows screws Min. 19/32-inch plywood at max. 24- 12-inch o.c. in 4-inch inch spans attached One or more Prelim. Elastobase or Elastobase OMG Flat Bottom lap and 12-inch o.c. One or more SBS- SBS-SA, APP- W-20 4-inch o.c. with 8d layers, any Attached Poly with poly top surface Plates (square) with in two, equally SA, SBS-TA or SA, SBS-TA or -60.0 common nails or 6- combination Roofgrip #12 spaced, staggered APP-TA APP-TA inch o.c. with #8 center rows screws Exterior Research and Design, LLC. d/b/a Trinity IERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 7 of 30 TABLE 1E: WOOD DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Roof Deck Base Sheet Roof Cover MDP (psf) Base Fasteners Attach Ply Cap No. Min. 19/32-inch plywood at Elastobase, Elastobase Poly, Polyglass 32 ga., 1-5/8-inch diameter 8-inch o.c. in 4-inch lap (Optional) One or W-21 max. 24-inch spans attached G2 Base, CertainTeed Glasbase, tin caps with 11 ga. annular and 8-inch o.c. in more BP -AA, SBS-AA, SBS- -52.5 6-inch o.c. with 8d common Firestone MB Base, IM Perma-Ply 28, ring shank nails three, equally spaced, SBS-AA, SBS-TA TA, APP-TA nails Tamko Glass Base or GAFGLAS #75 staggered center rows or APP-TA Min. 19/32-inch plywood at 32 ga., 1-5/8-inch diameter(Optional) 8-inch o.c. in 4-inch lap One or SBS-SA, APP- yy-22 max. 24-inch spans attached Elastobase or Elastobase Poly with poly tin caps with it ga. annular and B-inch o.c. in more SBS-SA, SA, SBS-TA or -52.5 6-inch o.c. with 8d common top surface ring shank nails three, equally spaced, SBS-TA or APP-TA APP-TA nails staggered center rows Min. 19/32-inch plywood at Elastobase, Elastobase Poly, Polyglass OMG Flat Bottom Plates (square) with Roofgrip #14, 12-inch o.c. in 4-inch (Optional) One or W 23 max. 24-inch spans attached G2 Base, CertainTeed Glasbase Dekfast Hex with Dekfast lap and 12-inch o.c. in more BP -AA, SBS-AA, SBS- -52.5 6-inch o.c. with 8d common Firestone MB Base, IM Perma-Piy 28, #14 or TruFast MP-3 with two, equally spaced, SBS-AA, SBS-TA TA, APP-TA nails Tamko Glass Base or GAFGLAS #75 TruFast HD staggered center rows or APP-TA Min. 19/32-inch plywood at OMG Flat Bottom Plates (square) with Roofgrip #14, 12-inch o.c. in 4-inch One or more SBS- SBS-SA, APP- W-24 max. 24-inch spans attached Elastobase or Elastobase Poly with poly Dekfast Hex with Dekfast lap and inch in SA, SBS-TA or SA, SBS-TA or -52.5 6-inch o.c. with 8d common top surface #14 or TruFast MP-3 with ced two, equalllly spaced, a APP-TA APP-TA nails TruFast HD staggered center rows Min. 19/32-inch plywood at max. 24-inch spans attached Elastobase, Elastobase Poly, Polyglass 32 ga., 1-5/8-inch diameter 8-inch o.c. in 4-inch lap (Optional) One or W-25 4-inch with Bd common G2 Base, CertainTeed Glasbase, Firestone MB Base, IM Perma-Ply 28, tin caps with 11 ga. annular and 8-inch o.c. in three, equally spaced, more BP -AA, SBS-AA, SBS-TA SBS-AA, SBS- TA, APP-TA -60.0 6- nails or 6-inch o.c. with #8 Tamko Glass Base or GAFGLAS #75 ring shank nails staggered center rows or APP-TA screws Min. 19/32-inch plywood at 8-inch o.c. in 4-inch lap max. 24-inch spans attached Elastobase or Elastobase Poly with poly 32 ga., 1-5/8-inch diameter and 8-inch ocin . (Optional) One or SBS-SA, APP- W-26 4-inch o.c. with 8d common top surface tin caps with it ga, annular three, equally. spaced, more SBS-SA, SA, SBS-TA or -60.0 nails or 6-inch o.c. with #8 ring shank nails staggered center rows SBS-TA or APP-TA APP-TA screws Min. 19/32-inch plywood at 12-inch o.c. in 4-inch (Optional) One or max. 24-inch spans attached OMG Flat Bottom Plates lap and 12-inch o.c. in more BP -AA, SBS-AA, SBS- -60.0 W-27 4-inch o.c. with 8d common Elastobase or Elastobase Poly (square) with Roofgrip #12 two, equally spaced, SBS-AA, SBS-TA TA, APP-TA nails or 6-inch o.c. with #8 staggered center rows or APP-TA screws Min. 19/32-inch plywood at 12-inch o.c. in 4-inch max. 24-inch spans attached Elastobase or Elastobase Poly with poly OMG Flat Bottom Plates lap and 12-inch o.c. in One or more SBS- SA, SBS-TA or SBS-SA, APP- SA, SBS-TA or -60.0 W-28 4-inch o.c. with 8d common top surface (square) with Roofgrip #12 two, equally spaced, APP-TA APP-TA nails or 6-inch o.c. with #8 staggered center rows screws Min. 19/32-inch plywood at Elastobase or Elastobase Poly with poly 32 ga., 1-5/8-inch diameter 4-inch o.c. in 4-inch lap and 4-inch o.c. in four, (Optional) One or SBS-SA, APP- W-29 max. 24-inch spans attached top surface caps with 11 ga, annular equally spaced, equally more SBS-SA, SA, SBS-TA or -97.5 6-inch o.c. with #8 screws ring shank nails. staggered center rows SBS-TA or APP-TA APP-TA Exterior Research and Design, LLC. d/b/a Trinity IERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report P9290.02.08-RB for FL1654-RlO Revision 8: 12/06/2011 Appendix 1, Page 8 of 30 `�J TRINIIYIERD TABLE 3E: WOOD DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Roof Deck Base Sheet Roof Cover MOP (psf) Base Fasteners Attach Ply Cap No. Min. 19/-inch h plywood at 32 ga., inch diameter 6-inch o.c. in 4-inch lap and 6-inch o.c. in four, (Optional) One or more BP -AA, SBS-AA, SBS- W-30 max. 24-inch spans attached Elastobase or Elastobase Poly tin caps with 11 ga. annular with equally spaced, SBS-AA, SBS-TA TA, APP-TA -112.5 6-inch o.c. with #8 screws ring shank nails staggered center rows or APP-TA 32 ga., inch diameter 6-inch o.c. in 4-inch lap .. (Optional) One or more SBS-SA (no W-31 Min. 19/32-inch plywood at max. 24-inch spans attached Elastobase or Elastobase Poly with poly tin caps with 11 ga. annular with ring shank nails. Note: Tin and 6-inch o.c. in four, Elastoflex SA V SBS-SA, APP- SA, SBS-TA or 112.5 6 inch o.c. with #8 screws top surface caps are to be primed with equally spaced, staggered center rows Base or Elastoflex SA V FR Base), APP-TA PG100 or ASTM D41 primer. SBS-TA or APP-TA TABLE 1F: WOOD DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE F: NON -INSULATED, BONDED ROOF COVER Roof Cover System No. Deck Primer MOP (psf) Joint Treatment Base Ply Cap Min. 19/32-inch plywood at W-32 max. 24-inch spans attached 6- (Optional) PG100 None SBS-SA (Optional) SBS-SA, SBS-SA, APP-SA, -90.0 inch o.c. with 8d ring shank SBS-TA or APP-TA SBS-TA or APP-TA nails Min. 15/32-inch plywood at Plywood joints are covered with 4-inch Elastoflex SA V l) (Optional) (Optional) SBS-SA, P-SA, SBS-SA, APP-SA, W-33 max. 24-inch spans attached 6- (Optional) PG100 wide strips of Elastoflex SA V Plus, rolled Base or Elastoflex S S-TA APP-TA SBS-TA or -97.5 inch o.c. with #12 screws into place to create continuous bond. SA V FR Base Min. 15/32-inch plywood at Plywood joints are covered with 4-inch Elastoflex SA V Plus (Optional) SBS-SA, SBS-SA, APP-SA, W-34 max. 24-inch spans attached 6- (Optional) PG100 wide strips of Elastoflex SA V Plus, rolled or Elastoflex SA V SBS TA or APP-TA SBS-TA or APP-TA -135.0 inch o.c. with #12 screws into place to create continuous bond. Plus FR Exterior Research and Design, LLC. d/b/a Trinity IERD Evaluation Report P9290.02.08-118 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 9 of 30 QOTRINITYIERD TABLE 2A: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System Base Insulation Layer Top Insulation Layer Roof Cover MDP No. Roof Deck Type Fasteners Attach Type Attach Base Ply Cap (psf) Min. 22 ga., type B, Min. 1.5-inch Dekfast Hex with Dekfast #14, Trufast Min. 0.75-inch (Optional if (Optional if using AA Base) One or SBS-AA, SC-1. Grade 33 steel or ACFoam II, ENRGY MP-3 with Trufast HD 1 per 2 FescoBoard or min. HA using AA Ply) more BP -AA, SBS- SBS-TA, -45.0* min. 2,500 psi 3, H-Shield or or OMG 3-inch Galv ftZ 0.5-inch Structodek BP -AA, SBS-AA AA, SBS-TA or APP-TA structrual concrete Polytherm Plate with OMD HD HD Fiberboard APP-TA Min. 22 ga., type B, Min. 2-inch Dekfast Hex with Dekfast #14, Trufast Min. 0.75-inch (Optional if (Optional if using AA Base) One or SBS-AA, SC-2. Grade 33 steel or ACFoam II, ENRGY with Trufast HD 1 per 4 FescoBoard or min. HA using Ply) more BP -AA, SBS SBS-TA, -45.0* min. 2,500 psi 3, H-Shield or or 3-inch or O ftZ 0.5-inch Structodek BP -AA, SBS-AA , S AA, SBS-TA or APP-TA structrual concrete Polytherm HD Plate with OMD HD to w HD Fiberboard APP-TA Min. 22 ga., type B, Min. 1.5-inch Dekfast Hex with Min. 0.75-inch (Optional if (Optional if using AA Base) One or SBS-AA, SC-3. Grade 33 steel or ENRGY 3, H-Shield Dekfast #14 or 1 per FescoBoard or min. HA using AA Ply) more BP -AA, SBS- SBS-TA, -90.0 min. 2,500 psi or Polytherm TruFast MP-3 with 1.33 ftZ 0.5-inch Structodek BP -AA, SBS-AA AA, SBS-TA or APP-TA structrual concrete TruFast HD HD Fiberboard APP-TA Min. 22 ga., type B, Min. 1.5-inch Dekfast Hex with Min. 0.75-inch BP -AA, SBS-AA One or more SBS-SA, SC-4. Grade 33 steel or ENRGY 3, H Shield Dekfast #14 or 1 per FescoBoard or min. HA (Top surface layers, APP-SA, SBS-TA -90.0 min. 2,500 psi or Polytherm TruFast MP-3 with 1.33 ftZ 0.5-inch Structodek primed with SBS-TA or APP-TA or APP, or structrual concrete TruFast HD HD Fiberboard PG100 primer) APP-TA TABLE 2B: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System Roof Deck Base Insulation Top Insulation Layer Roof Cover MDP s (p Type Fasteners Attach Base Ply Cap No. Layer (Optional) (Optional if using Min. 22 ga., type B, Grade Min. 0.5-inch OMG 3-inch Galvalume 1 (Optional if using AA Base) One or SBS-AA, SC-5. 33 steel or min. 2,500 psi One or more layers, SECUROCK Gypsum- Steel Plate with OMG #14 per 1.78 ft' AA Ply) BP -AA, more BP -AA, SBS-TA, -75.0 structrual concrete any combination, Fiber Roof Board HD SBS-AA SBS-AA, SBS-TA APP-TA loose laid or APP-TA Min. 0.5-inch Structodek HD Dekfast Galvalume Steel (Optional if using Min. 22 ga., type B, Grade One or more layers, Fiberboard or min. Hex with Dekfast #12 (steel 1 per p (Optional if using AA Base) One or SBS-AA, SC-6. 33 steel or min. 2,500 psi any combination, 0.25-inch DensDeck, only) or #14 or TruFast MP- 1.33 ftZ AA Ply) BP -AA, more BP -AA, SBS-TA, -82.5 structrual concrete loose laid DensDeck Prime or 3 with TruFast DP (steel SBS-AA SBS-AA, SBS-TA APP-TA SECUROCK Gypsum- only) or HD or APP-TA Fiber Roof Board (Optional) Dekfast Galvalume Steel (Optional) One SBS-AA, Min. 22 ga., type B, Grade more la One or layers, Min. 1.5-inch ENRGY Hex with Dekfast #12 (steel 1 per or more SBS-AA, SBS-TA, SC-7. 33 steel or min. 2,500 psi any combination, 3, H-Shield or only) or #14 or TruFast MP- 1.33 ftZ SBS-SA SBS-TA, SBS-SA SBS-SA, -82.5 structrual concrete Polytherm 3 with TruFast DP (steel or APP-TA APP-TA, loose laid only) or HD APP-SA Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 10 of 30 TABLE 2C: STEEL OR CONCRETE DECKS — NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER SYSTEM TYPE D: PRELIMINARILY ATTACHED INSULATION, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER NOTE: INSULATION IS OPTIONAL FOR RECOVER APPLICATIONS System Insulation Layer(s) Base Sheet Roof Cover MDP No. Roof Deck Type Attach Base Fasteners Attach Ply Cap (psf) Min. 22 ga., type B, One or more Elastobase, Elastobase OMG Flat Bottom Plates (square) with Roofgrip 12-inch o.c. in 4-inch la and P (Optional) One ( P ) SBS-AA, SC-8. Grade 33 steel or layers, any Prelim. Poly or )M Perma-Ply #14, Dekfast Hex with 18-inch stag in two, equally or more BP -AA, SBS-TA, -45.0* min. 2,500 psi combination Attached 28 Dekfast #14 orTruFast spaced, staggered center SBS-AA, SBS-TA APP-TA structrual concrete MP-3 with TruFast HD rows or APP-TA Elastobase, Elastobase Min. 22 ga., type B, One or more Poly, Polyglass G2 Base, CertainTeed OMG Flat Bottom Plates (square) with Roofgrip 12-inch stag in 4-inch lap and (Optional) One SBS-AA, SC-9. Grade 33 steel or layers, any Prelim. Glasbase, Firestone #14, Dekfast Hex with stag in two, equally or more BP -AA, SBS-TA, -52.5 min. 2,500 psi combination Attached MB Base, JM Perma- Dekfast #14 or TruFast spaced, staggered center spaced, SBS-TA APP-TA structrual concrete Ply 28, Tamko Glass MP-3 with TruFast HD rows or APP-, or APP-TA Base or GAFGLAS #75 Min. 22 ga., type B, One or more Elastobase or OMG Flat Bottom Plates (square) with Roofgrip 12-inch o.c. in 4-inch la and P One or more SBS-SA, SC-10. Grade steel or min, 2,5500 psi layers, any Prelim. Attached Elastobase Poly with #14, Dekfast Hex with spaced, staggered center -inch stag in two, equally spaced, SBS-SA, SBS-TA APP-SA, SBS-TA or -52.5 structrual concrete combination poly top surface Dekfast #14 or TruFast rows or APP-TA APP-TA MP-3 with TruFast HD Min. 22 ga., type B, One or more OMG Flat Bottom Plates 12-inch o.c. in 4-inch lap and (Optional) One SBS-AA, SC-11. Grade 33 steel or layers, any Prelim. Elastobase or (square) with Roofgrip 12-inch stag in two, equally or more BP -AA, SBS-TA, -60.0 min. psi combination Attached Elastobase Poly #12 (steel only) or #14 spaced, staggered center SBS-TA APP-TA structrual concrete structrual rows or APP-, or APP-TA Min. 22 ga., type B, Grade 33 steel a One or more Prelim. Elastobase or OMG Flat Bottom Plates 12-inch o.c. in 4-inch lap and 12-inch stag in two, equally One or more SBS-SA, APP-SA, SC-12. min. 2,500 psi layers, any Attached Elastobase Poly with (square) with Roofgrip spaced, staggered center SBS-SA, SBS-TA or -60.0 structrual concrete combination poly top surface #12 (steel only) or #14 or APP-TA APP-TA Min. 22 ga., type B, Grade 80 steel or One or more Prelim. Dekfast isofast IF-2.375- 12-inch stag in the 5-inch-(Optional) APP- SBS-TA, -82.5 SC-13. min. 2,500 psi layers, any Attached Polyflex AT Plates with Dekfast wide, heat -welded side lap TA APP-TA structrual concrete combination #15 HS Min. 22 ga., type B, Grade 80 steel or One or more Prelim. Trufast 2.4 in. Barbed 12-inch stag in the 6-inch (Optional) APP- SBS-TA, -82.5 SC-14. min. 2,500 psi layers, any Attached Polybond or Polyflex Seam Plates with Trufast wide, heat -welded side lap TA APP-TA structrual concrete combination EHD Fasteners Min. 22 ga., type B, Dekfast Hex with Dekfast 12-inch o.c. in the 4-inch lap (Optional) BP- SBS-AA, SC-15. Grade 33 steel or One or morePrelim. layers, any Polybond, Polyflex or #14 or OMG Flat Bottom and 18-inch stag in two, AA, SBS-AA, SBS-TA, -112.5 min. 2,500 psi Attached Elastoshield Plates with OMG Roofgrip equally spaced, staggered SBS-TA or APP- APP-TA structrual concrete combination #14 center rows TA Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 11 of 30 TABLE 3A-1: CONCRETE DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System Base Insulation Layer Top Insulation Layer Roof Cover MOP No. Deck Primer Type Attach I Type Attach Base Ply Cap (psf) SELF -ADHERING SYSTEMS WITH BASE INSULATION AND OPTIONAL TOP INSULATION OF THE SAME TYPE: (Optional) Min. 1.5-inch H-Shield or Multi- D-IS (Optional) additional D-IS SBS-SA (Optional) One or more SBS-SA, SBS-SA, APP- SA, SBS-TA or -67.5 C-1 Concrete pG100 Max FA3 layers(s) of base insulation SBS-TA or APP-TA APP-TA C-2 Concrete (Optional) Min. 1.5-inch ACFoam II or D-IS (Optional) additional D-IS SBS-SA (Optional) One or more SBS-SA, SBS-SA, APP- SA, SBS-TA or -135.0 pG100 ENRGY 3 layers(s) of base insulation SBS-TA or APP-TA APP-TA C-3 Concrete None Min. 1.5 inch, min. 1.5 pcf EPS D-IS (Optional) additional layers D-IS SBS-SA (Optional) One or more SBS-SA, SBS-SA, APP- SA, SBS-TA or -157.5 insulation board of base insulation SBS-TA or APP-TA APP-TA C-4 Concrete None Min. 1.5-inch, min. 2.0 pcf EPS OB500 (Optional) additional layers OB500 SBS-SA (Optional) One or more SBS-SA, SBS-SA, APP- SA, SBS-TA or -120.0 insulation board of base insulation SBS-TA or APP-TA APP-TA (Optional) additional (Optional) One or SBS-SA, APP- C-5 Concrete None Min. 1.5-inch ENRGY 3 OB500 layers(s) of base insulation OB500 SBS-SA more SBS-SA, SA, SBS-TA or -127.5 SBS-TA or APP-TA APP-TA C-6 Concrete None Min. 1.5-inch ACFoam II, or H- OB500 (Optional) additional OB500 SBS-SA (Optional) One or more SBS-SA, SBS-SA, APP- SA, SBS-TA or -150.0 Shield layers(s) of base insulation SBS-TA or APP-TA APP-TA Min. 1.5-inch ACFoam II, (Optional) additional (Optional) One or SBS-SA, APP- C-7 Concrete None ENRGY 3, H-Shield or Multi -Max M-OSFA layers(s) of base insulation M-OSFA SBS-SA more SBS-SA, SA, SBS-TA or -232.5 FA3 SBS-TA or APP-TA APP-TA C-8 Concrete None Min. 1.5-inch, min. 2.0 pcf EPS CR-20 (Optional) additional layers CR-20 SBS-SA (Optional) One or more SBS-SA, SBS-SA, APP- SA, SBS-TA or -240.0 insulation board of base insulation SBS-TA or APP-TA APP-TA Min. 1.5-inch ACFoam II, (Optional) One or SBS-SA, APP- C-9 Concrete None ACFoam III, ENRGY 3, H-Shield, CR-20 (Optional) additional CR-20 SBS-SA more SBS-SA, SA, SBS-TA or -270.0 H-Shield CG , Multi -Max FA3, or layers(s) of base insulation SBS-TA or APP-TA APP-TA ISO 95+ GL C-10 Concrete None Min. 2-inch ACFoam II or H- OB Classic (Optional) additional OB Classic SBS-SA (Optional) One or more SBS-SA, SBS-SA, APP- SA, SBS-TA or -270.0 Shield layers(s) of base insulation SBS-TA or APP-TA APP-TA Min. 1.5-inch ACFoam II, (Optional) additional (Optional) One or SBS-SA, APP- C-11 Concrete PG100 ACFoam III, ENRGY 3, H-Shield, HA layers(s) of base insulation HA SBS-SA more SBS-SA, SA, SBS-TA or -480.0 H-Shield CG or Multi -Max FA3 SBS-TA or APP-TA APP-TA SELF -ADHERING SYSTEMS WITH BASE INSULATION AND COVERBOARD: Min. 0.25-inch SECUROCK (Optional) One or SBS-SA, APP- C-12 Concrete None Min. 1.5-inch Multi -Max FA3 D-IS Gypsum -Fiber Roof Board D-IS SBS-SA more SBS-SA, SA, SBS-TA or -67.5 SBS-TA or APP-TA APP-TA Min. 1.5-inch, min. 2.0 pcf Min. 0.25-inch DensDeck, (Optional) One or SBS-SA, APP- C-13 Concrete None ASTM C578 Expanded D-IS - _ DensDeck Prime D-IS SBS-SA more SBS APP-TA SA, SBS-TA or -120.0 _ Polystyrene SBS-TA or A APP-TA Exterior Research and Design, LLC, d/b/a Trinity IERD Evaluation Report P9290.02.08-118 for FL1654-RIO Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 12 of 30 TABLE 3A-1: CONCRETE DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System Base Insulation Layer Top Insulation Layer Roof Cover MDP No. Deck Primer (psf) Type Attach Type Attach Base Ply Cap C-14 Concrete None Min. 2-inch ACFoam II, ENRGY- D-IS Min. 0.25-inch SECUROCK D-IS SBS-SA (Optional) One or more SBS-SA, SBS-SA, APP- SA, SBS-TA or -247.5 3 or H-Shield Gypsum -Fiber Roof Board SBS-TA or APP-TA APP-TA Min. 0.25-inch DensDeck, (Optional) One or SBS-SA, APP- C-15 Concrete None Min. 1.5-inch ENRGY 3 OB500 DensDeck Prime OB500 SBS-SA more SBS-SA, SA, SBS-TA or -127.5 SBS-TA or APP-TA APP-TA C-16 Concrete None CFoa Min. 1.5-inch ACFoam II, H- OB500 Min. 0.25-inch DensDeck, OB500 SBS-SA (Optional) One or more SBS-SA, SBS-SA, APP- SA, SBS-TA or -150.0 Shield or ISO DensDeck Prime SBS-TA or APP-TA APP-TA (Optional) One or SBS-SA, APP- C-17 Concrete None Min. 2-inch ACFoam II, ENRGY- n. OB500 Min. 0.25-inch SECUROCK OB500 SBS-SA more SBS-SA, SA, SBS-TA or -247.5 3 H-Shield Gypsum -Fiber Roof Board SBS-TA or APP-TA APP-TA Min. 1.5-inch ACFoam II, Min. 0.25-inch SECUROCK (Optional) One or SBS-SA, APP- C-18 Concrete None ENRGY 3, H-Shield or Multi -Max M-OSFA Gypsum -Fiber Roof Board M-OSFA SBS-SA more SBS-SA, SA, SBS-TA or -232.5 FA3 SBS-TA or APP-TA APP-TA C-19 Concrete None Min. 2-inch ACFoam II, ENRGY- n. M-OSFA Min. 0.25-inch SECUROCK M-OSFA SBS-SA (Optional) One or more SBS-SA, SBS-SA, APP- SA, SBS-TA or -247.5 3 H-Shield Gypsum -Fiber Roof Board SBS-TA or APP-TA APP-TA Min. 1.5-inch, min. 2.0 pcf Min. 0.25-inch DensDeck, (Optional) One or SBS-SA, APP- C-20 Concrete None ASTM C578 Expanded CR-20 DensDeck Prime CR-20 SBS-SA more SBS-SA, SA, SBS-TA or -240.0 Polystyrene SBS-TA or APP-TA APP-TA Min. 2-inch ACFoam IV, min. 1.5-inch Ultra -Max or Multi -Max Min. 0m-Fibernch (Optional) One or SBS-SA, APP- C-21 Concrete None FA-3, min. 1.3-inch ACFoam III CR-20 Roof BoardROCK Gypsum -Fiber Roof Board CR-20 SBS-SA more SBS-SA, SA, SBS-TA or -240.0 or min. 1.0-inch ISO 95+GL, H- SBS-TA or APP-TA APP-TA Shield, H-Shield CG or ENRGY 3 C-22 Concrete None Min. 2-inch ACFoam II, ENRGY- CR-20 Min. 0.25-inch SECUROCK CR-20 SBS-SA (Optional) One or more SBS-SA, SBS-SA, APP- SA, SBS-TA or -247.5 3 or H-Shield Gypsum -Fiber Roof Board SBS-TA or APP-TA APP-TA C-23 Concrete None Min. 2-inch ACFoam II or H- OB Classic Min. 0.25-inch SECUROCK OB Classic SBS-SA (Optional) One or more SBS-SA, SBS-SA, APP- SA, SBS-TA or -350.0 Shield Gypsum -Fiber Roof Board SBS-TA or APP-TA APP-TA Min. 1.5-inch ACFoam II, Min. 0.25-inch SECUROCK (Optional) One or SBS-SA, APP- C 24 Concrete PG100 ACFoam III, ENRGY 3, H-Shield, HA Gypsum -Fiber Roof Board HA SBS-SA more SBS-SA, SA, SBS-TA or -350.0 H-Shield CG or Multi -Max FA3 SBS-TA or APP-TA APP-TA Exterior Research and Design, LLC. d/b/a Trinity IERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 13 of 30 k TABLE 3A-1 (Continued): CONCRETE DECKS - NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System Base Insulation Layer Top Insulation Layer Roof Cover MDP No. Deck Primer Type Attach Type Attach Base Ply Cap (psi ASPHALT AND/oR TORCH APPLIED SYSTEMS: C-25 Concrete None Min. 2-inch ACFoam II or D-IS Min. 0.25-inch SECUROCK Gypsum- D-IS BP -AA, SBS-AA (Optional) One or SBS-AA -225.0 H-Shield Fiber Roof Board more BP -AA, SBS-AA C-26 Concrete None Min. 2-inch ACFoam II or D-IS Min. 0.25-inch SECUROCK Gypsum- D-IS APP-TA (Optional) One or APP-TA -232.5 H-Shield Fiber Roof Board more APP-TA C-27 Concrete None Min. inch ACFoam II or OB500 Min. 0.25-inch SECUROCK Gypsum- OB500 BP -AA, SBS-AA (Optional) One or SBS-AA -225.0 e H-Shield Fiber Roof Board more BP -AA, SBS-AA C-28 Concrete None Min. 2-inch ACFoam II or OB500 Min. 0.25-inch SECUROCK Gypsum- OB500 APP-TA (Optional) One or APP-TA -232.5 H-Shield Fiber Roof Board more APP-TA C-29 Concrete None Min. 2-inch ACFoam II or M-OSFA Min. 0.25-inch SECUROCK Gypsum- M-OSFA BP -AA, SBS-AA (Optional) One SBS-AA -225.0 H-Shield Fiber Roof Board more BP -AA, SBS-AA C-30 Concrete None Min. 2-inch ACFoam II or M-OSFA Min. 0.25-inch SECUROCK Gypsum- M-OSFA APP-TA (Optional) One or APP-TA -232.5 H-Shield Fiber Roof Board more APP-TA Min. 2-inch ACFoam IV, min. 1.5-inch Ultra -Max or Multi -Max FA-3, min. 1.3- Min. 0.25-inch (Optional) One or C-31 Concrete None inch ACFoam III or min. CR-20 SECUROCK Gypsum- CR-20 BP -AA, SBS-AA more BP -AA, SBS-AA SBS-AA -225.0 1.0-inch ISO 95+GL, H- Fiber Roof Board Shield, H-Shield CG or ENRGY 3 Min. 2-inch ACFoam IV, min. 1.5-inch Ultra -Max or Multi -Max FA-3, min. 1.3- Min. 0.25-inch (Optional) One or C-32 Concrete None inch ACFoam III or min. CR-20 SECUROCK Gypsum- CR-20 APP-TA more APP-TA APP-TA -232.5 1.0-inch ISO 95+GL, H- Fiber Roof Board Shield, H-Shield CG or ENRGY 3 C-33 Concrete None (Optional) Min. 2-inch OB Classic Min. 0.25-inch SECUROCK Gypsum- OB Classic BP -AA, SBS-AA (Optional) One or SBS-AA -225.0 ACFoam II or H-Shield Fiber Roof Board more BP -AA, SBS-AA C-34 Concrete None (Optional) Min. 2-inch OB Classic Min. 0.25-inch SECUROCK Gypsum- OB Classic APP-TA (Optional) One or APP-TA -232.5 ACFoam II or H-Shield Fiber Roof Board more APP-TA Min. 1.5-inch ACFoam II, Min. 0.25-inch C-35 Concrete PG100 ACFoam III, ENRGY 31 H- Shield, H-Shield CG or HA SECUROCK Gypsum- HA BP -AA, SBS-AA (Optional) One more BP -AA, SBS-AA SBS-AA -225.0 _ _ Multi -Max FA3 _ __Fiber Roof Board_ - - Exterior Research and Design, LLC. d/b/a Trinity IERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 14 of 30 TABLE 3A-1 (Continued): CONCRETE DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System Base Insulation Layer Top Insulation Layer Roof Cover MOP No. Deck Primer Type Attach Type Attach Base Ply Cap (Psf) ASPHALT AND/OR TORCH APPLIED SYSTEMS: Min. 1.5-inch ACFoam II, Min. 0.25-inch C-36 Concrete PG100 ACFoam III, ENRGY 3, H- HA SECUROCK Gypsum- HA APP-TA (Optional) One or APP-TA APP-TA -232.5 Shield, H-Shield CG or Fiber Roof Board more Multi -Max FA3 (Optional if using AA (Optional if using AA C-37 Concrete PG100 Min. 0.75-inch FescoBoard HA None N/A Ply) One or more BP- Base) One or more BP -AA, SBS-AA, SBS- SBS-AA, SBS- TA, APP-TA -277 5 AA, SBS-AA TA or APP-TA Min. 1.5-inch ACFoam II, (Optional if using AA (Optional if using AA C-38 Concrete PG100 ACFoam III, ENRGY 3, H- HA Min. 0.75-inch Fesco HA Ply) One or more BP- Base) One or more SBS-AA, SBS- -290.0 Shield, H-Shield CG or Board AA, SBS-AA BP -AA, SBS-AA, SBS- TA, APP-TA Multi -Max FA3 TA or APP-TA (Optional if using AA (Optional if using AA C-39 Concrete PG100 Min. 0.5-inch Structodek HA None N/A Ply) One or more BP- OneSBSor Base) One or more SBS-AA, SBS- -285.0 HD Fiberboard AA, BP -AA, SBS-AA, SBS- TA, APP-TA TA or APP-TA Min. 1.5-inch ACFoam II, Min. 0.5-inch (Optional if using AA (Optional if using AA C-40 Concrete PG100 ACFoam III, ENRGY 31 H- Shield, H-Shield CG or HA Structodek HD HA Ply) One or more BP- Base) One or more BP -AA, SBS-AA, SBS- SBS-AA, SBS- TA, APP-TA -480.0 Multi -Max FA3 Fiberboard AA, SBS-AA TA or APP-TA Min. 1.5-inch ACFoam II, (Optional if using AA (Optional if using AA C-41 Concrete PG100 ACFoam III, ENRGY 31 H- HA Min. 0.25-inch HA Ply, One or more BP- Base) One or more SBS-AA, SBS- -480.0 Shield, H-Shield CG or DensDeck Prime AA, SBS-AA BP -AA, SBS-AA, SBS- TA, APP-TA Multi -Max FA3 TA or APP-TA (Optional if using AA (Optional if using AA C-42 Concrete PG100 Min. 0.25-inch DensDeck HA None N/A Ply) One or more BP- Base) One more SBS-AA, SBS- -510.0 Prime AA, SBS-AA BP -AA, SBS-AA, SBS- TA, APP-TA TA or APP-TA Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report 139290.02.08-118 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 15 of 30 C�o \�JTRINITYJERD TABLE 3A-2: CONCRETE DECKS - NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE A-1: BONDED TEMP ROOF, BONDED INSULATION, BONDED ROOF COVER Syste Temp Base Insulation Layer Top Insulation Layer Roof Cover MDP m No. Deck Prime Roof (Psf) Type Attach Type Attach Base Ply Cap Min. 1.5-inch, min. 2.0 pcf (Optional if using polyisocyanurate base (Optional) C-43 Conc PG100 Elastoflex ASTM C578 Expanded Polystyrene or Min. 1.5-inch D-IS insulation) Min. 0.25-inch D-IS SBS-SA One or more SBS-SA,APP- SA, SBS-TA or -60.0 SA V Plus ACFoam II, ENRGY-3, H-Shield Prime or SBS- APP-TA SECDensDeck Gypsum -Fiber TA or A, TA or APP-TA or Multi -Max FA3 Roof BoardROCK Roof Board Elastoflex (Optional if using SA P or Min. 1.5-inch, min. 2.0 pcf polyisocyanurate base (Optional) SBS-SA, APP- C-44 Conc PG100 Polyglass ASTM C578 Expanded D-IS insulation) Min. 0.25 inch D IS SBS-SA One or more SA, SBS-TA or -75.0 Base Polystyrene or Min. 1.5-inch DensDeck Prime or SBS-SA, SBS- APP-TA (torched) ACFoam II or ENRGY 3 SECUROCK Gypsum -Fiber TA or APP-TA Roof Board Min. 1.5-inch, min. 2.0 pcf (Optional if using ASTM C578 Expanded polyisocyanurate base (Optional) SBS-SA, APP- C-45 Conc PG100 Elastoflex Polystyrene or Min. 1.5-inch CR-20 insulation) Min. 0.25-inch CR-20 SBS-SA One or more SA, SBS-TA or -60.0 SA V Plus ACFoam II, ACFoam III, ENRGY DensDeck Prime or SBS-SA, SBS- APP-TA 3, H-Shield, H-Shield CG, Multi- SECUROCK Gypsum -Fiber TA or APP-TA Max FA3 or ISO 95+GL Roof Board Min. 1.5-inch, min. 2.0 pcf (Optional if using Polyglass ASTM C578 Expanded polyisocyanurate base (Optional) SBS-SA, APP- C 46 Conc PG100 Base, Polystyrene or Min. 1.5-inch CR-20 insulation) Min. 0.25-inch CR-20 SBS-SA One or more SA, SBS-TA or -75.0 (torched) ACFoam II, ACFoam III, ENRGY DensDeck Prime or SBS-SA, SBS- APP-TA 3, H-Shield, H-Shield CG, Multi- SECUROCK Gypsum -Fiber TA or APP-TA Max FA3 or ISO 95+GL Roof Board Min. 1.5-inch, min. 2.0 pcf Min. 0.25-inch DensDeck, (Optional) SBS-SA, APP- C-47 Conc PG100 Elastoflex ASTM C578 Expanded CR-20 DensDeck Prime or CR-20 SBS-SA One or more SA, SBS-TA or -240.0 SAP polystyrene SECUROCK Gypsum -Fiber SBS-SA, SBS- APP-TA Roof Board TA or APP-TA Min. 1.5-inch ACFoam II, (Optional) SBS-SA, APP- C 48 Conc PG100 Elastoflex ACFoam III, ENRGY 3, H-Shield, CR-20 (Optional) Additional layers CR-20 SBS-SA One or more SA, SBS-TA or -250.0 SA P H-Shield CG, Multi -Max FA3 or of base insulation SBS-SA, SBS- APP-TA ISO 95+GL TA or APP-TA Min. 0.5-inch Temple HD6 Min. 1.5-inch ACFoam II, or Structodek HD (Optional) SBS-SA, APP- C 49 Conc PG100 Elastoflex ACFoam III, ENRGY 3, H-Shield, CR-20 Fiberboard or min. 0.25- CR-20 SBS-SA One or more SA, SBS-TA or -270.0 SA P H-Shield CG, Multi -Max FA3 or inch DensDeck, DensDeck SBS-SA, SBS- APP-TA ISO 95+GL Prime or SECUROCK TA or APP-TA Gypsum -Fiber Roof Board Elastoflex (Optional if SA V Vent, Min. 0.25-inch DensDeck or (Optional if using AA SA V Vent Min. 1.5-inch ACFoam II, DensDeck Prime, min. 0.5- using AA Base) One or SBS-AA, SBS- C-50 Conc PG100 FR or SA V ENRGY 3, H-Shield, ISO 95+ HA inch Structodek HD HA Ply) BP -AA, more BP -AA, TA, APP-TA -280.0 Plus GL, Multi -Max FA3 or Polytherm Fiberboard or min. 0.75- SBS-AA SBS-AA, SBS- _ _ followed by inch Fesco Board TA or APP-TA APP=TA - Exterior Research and Design, LLC. d/b/a Trinity IERD Evaluation Report P9290.02.08-R8 for FL1654-RlO Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 16 of 30 TABLE 3B: CONCRETE DECKS - NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE F: NON -INSULATED, BONDED BASE SHEET, BONDED ROOF COVER Roof Cover System No. Deck Primer MOP (psf) Base Ply Cap C-51 Concrete PG100 Elastoflex SA V Vent or SA V (Optional) SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -280.0 Vent FR C-52 Concrete PG100 SBS-SA (Optional) SBS-SA, SBS-TA or SBS-SA, APP-SA, SBS-TA or APP-TA -315.0 APP-TA BP -AA (Optional if using asphalt (Optional if using asphalt applied C-53 Concrete PG100 applied Ply) Base) BP -AA, SBS-AA, SBS TA or SBS-AA, SBS-TA, APP-TA -622.5 APP-TA Exterior Research and Design, LLC. d/b/a Trinity IERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 17 of 30 le r TABLE 4A: LIGHTWEIGHT CONCRETE DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Roof Deck Base Insulation Layer Coverboard Roof Cover System Y (See Note 1, Page 1) MDP (psf) No. Struct. LWC Type Attach Type Attach Base Ply Cap Deck SELF -ADHERING SYSTEMS WITH BASE INSULATION AND OPTIONAL TOP INSULATION OF THE SAME TYPE: Min. 200 psi, Min. 1.5-inchmin. 2.0 pcf ASTM (Optional) Additional, (Optoinal) One or more SBS- SBS-SA, APP- LWC-1 Concrete min 2-inch C578 expanded polystyrene OB500 layers of base OB500 SBS-SA SA, SBS-TA or SA, SBS-TA -120.0 Elastizell insulation APP-TA or APP-TA Min. 200 psi, Min. 1.5-inch ACFoam II, ENRGY (Optional) Additional (Optoinal) One or more SBS- SBS-SA, APP- LWC-2 Concrete min 2-inch 3, ISO 95+ GL or H-Shield OB500 layers of base OB500 SBS-SA SA, SBS-TA or SA, SBS-TA -225.0 Elastizell insulation APP-TA or APP-TA Min. 1.5-inch ACFoam II, (Optoinal) One Min. 200 psi, ACFoam III, ENRGY 3, ISO 95+ (Optional) Additional or more SBS- SBS-SA, APP- LWC-3 Concrete min. 2-inch GL, H-Shield, H-Shield CG, Multi- CR-20 layers of base CR-20 SBS-SA SA, SBS-TA or SA, SBS-TA -180.0 Elastizell Max FA3 or min. 2.0 pcf ASTM insulation APP-TA or APP-TA C578 expanded polystyrene Min. 200 psi, Min. 1.5-inch ACFoam II, ACFoam III, ENRGY 3, ISO 95+ (Optional) Additional (Optoinal) One SBS-SA, APP- LWC-4 Concrete min. 2-inch Celcore or GL, H-Shield, H-Shield CG, Multi- CR-20 layers of base CR-20 SBS-SA or more SBS- SA, SBS-TA or SA, SBS-TA -222.5 Mearlcrete Max FA3 or min. 2.0 pcf ASTM insulation APP-TA or APP-TA C578 expanded polystyrene SELF -ADHERING SYSTEMS WITH BASE INSULATION AND COVERBOARD: Min. 200 psi, Min. 1.5-inch, min. 2.0 pcf ASTM Min. 0.25-inch (Optoinal) One or more SBS- SBS-SA, APP- LWC-5 Concrete min 2-inch C578 expanded polystyrene OB500 SECUROCK Gypsum- OB500 SBS-SA SA, SBS-TA or SA, SBS-TA -120.0 Elastizell Fiber Roof Board APP-TA or APP-TA Min. 200 psi, Min. 1.5-inch ACFoam II, ENRGY Min. 0.25-inch (Optoinal) One or more SBS- SBS-SA, APP- LWC-6 Concrete min 2-inch 3, ISO 95+ GL or H-Shield OB500 SECUROCK Gypsum- OB500 SBS-SA SA, SBS-TA or SA, -225.0 Elastizell Fiber Roof Board APP-TA PP-TASBS-T or APP-TA Min. 1.5-inch ACFoam II, (Optoinal) One Min. 200 psi, ACFoam III, ENRGY 3, ISO 95+ Min. 0.25-inch or more SBS- SBS-SA, APP- LWC-7 Concrete min. 2-inch GL, H-Shield, H-Shield CG, Multi- CR-20 SECUROCK Gypsum- CR-20 SBS-SA SA, SBS-TA or SA, SBS-TA -180.0 Elastizell Max FA3 or min. 2.0 pcf ASTM Fiber Roof Board APP-TA or APP-TA C578 expanded polystyrene Min. 200 psi, Min. 1.5-inch ACFoam II, ACFoam III, ENRGY 3, ISO 95+ Min. 0.25-inch (Optoinal) One SBS-SA, APP- LWC-8 Concrete min. 2-inch GL, H-Shield, H-Shield CG, Multi- CR-20 SECUROCK Gypsum- CR-20 SBS-SA or more SBS- SA, SBS-TA or SA, -222.5 Celcore or Mearlcrete Max FA3 or min. 2.0 pcf ASTM Fiber Roof Board APP-TA PP -TA or AP -TA C578 expanded polystyrene ASPHALT AND/OR TORCH APPLIED SYSTEMS: Exterior Research and Design, LLC. d/b/a TrinitylERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report P9290.02.08-R8 for FL1654-R10 Revision 8: 12/06/2011 Appendix 1, Page 18 of 30 JAN TABLE 4A: LIGHTWEIGHT CONCRETE DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Roof Deck Base Insulation Layer Coverboard Roof Cover System y (See Note 1, Page 1) MDP (psf) No. Struct. LWC Type Attach Type Attach Base Ply Cap Deck Min. 200 psi, Min. 1.5-inch ACFoam II, ENRGY Min. 0.25-inch BP -AA, (Optional) One or more BP -AA, SBS-AA, LWC-9 Concrete min 2-inch 3, ISO 95+ GL or H-Shield OB500 SECUROCK Gypsum- OB500 SBS-AA, SBS-AA, SBS- SBS-TA, APP- -225.0 Elastizell Fiber Roof Board APP-TA TA or APP-TA TA Min. 1.5-inch ACFoam II, (Optional) One Min. 200 psi, ACFoam III, ENRGY 3, ISO 95+ Min. 0.25-inch BP -AA, or more BP -AA, SBS-AA, LWC-10 Concrete min. 2-inch GL, H-Shield, H-Shield CG, Multi- CR-20 SECUROCK Gypsum- CR-20 SBS-AA, SBS-AA, SBS- SBS-TA, APP- -180.0 Elastizell Max FA3 or min. 2.0 pcf ASTM Fiber Roof Board APP-TA TA or APP-TA TA C578 expanded polystyrene Min. 200 psi, Min. 1.5-inch ACFoam II, ACFoam III, ENRGY 3, ISO 95+ Min. 0.25-inch BP -AA, (Optional) One SBS-AA, LWC-11 Concrete min. 2-inch Celcore or GL, H-Shield, H-Shield CG, Multi- CR-20 SECUROCK Gypsum- CR-20 SBS-AA, or more B S- SBS-AA, SBS- SBS-TA, APP- -222.5 Mearlcrete Max FA3 or min. 2.0 pcf ASTM Fiber Roof Board APP-TA TA or APP-TA TA C578 expanded polystyrene TABLE 4B: LIGHTWEIGHT CONCRETE DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER Roof Deck (See Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover MDP System No. Struct LWC Type Fastsener Attach Type Attach Type Attach Base Ply Cap (psf) Min. 1.5-inch Min. 22 ga., Min. 300 7-inch o.c. at (Optional) Min. Thermaroof Composite, (Optional if Type B, psi 4-inch lap and 1.5-inch Polytherm (Optional if using AA SBS-AA, LWC-12 vented steel Approved GAFGLAS OMG CR 7-inch o.c. in ACFoam II, H- Composite, or min. HA using AA Base) One or SBS-TA, -45.0 at max. 5 ft cellular #75 BSF two, equally Shield, Multi- 0.HA inch odek Sta ply) BP -AA, more BP -AA, LWC spaced center Max FA3 or HD Fiberboard rd or SBS-AA SBS-AA, SBS- spans rows Polytherm mn. 0.75-inch min. TA or APP-TA FescoBoard Min. 22 ga., Min. 300 7-inch o.c. at 4-inch lap and Min. 1.5-inch (Optional) SBS-SA, LWC-13 Type B, vented steel psi Approved GAFGLAS OMG CR 7-inch o.c. in ACFoam II, H- Shield, Multi- HA None N/A SBS-SA One or more APP-SA, -45.0 at max. 5 ft cellular #75 BSF two, equally spaced center Max FA3 or SBS-SA, SBS- TA or APP-TA SBS-TA or APP-TA spans LWC Polytherm rows Exterior Research and Design, LLC. d/b/a Trinity IERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 19 of 30 \,f TRINil'YIEttD TABLE 4C: LIGHTWEIGHT CONCRETE DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER Roof Deck (See Note 1, Page 1) Base Sheet (See Note A below) Roof Cover MDP System Type (Psf) No. Structural Deck Lightweight Concrete (See Note A) Fasteners Attach Ply Cap 'GENERIC' CELLULAR LIGHTWEIGHT INSULATING CONCRETE: Min. 300 psi, min. 2-inch thick cellular LWC. Note: To Min. 22 ga., type B steel qualify the LWIC under this 7-inch o.c. in a 3-inch lap (Optional)One or LWC-14 at max 5 ft spans or assembly, an OMG CR BPF shall achieve an average B3 OMG CR BPF and 7-inch o.c. in two, equally spaced, staggered more BP -AA, SBS- SBS-AA, APP-TA -45.0 structural concrete withdrawal of 53 lbf when rows in the field of the sheet AA tested per TAS 105 or ANSI/SPRI FX-1 CELCORE CELLULAR LIGHTWEIGHT INSULATING CONCRETE: Min. 0.0179-inch 8-inch c. in a inch lap LWC-15 Tensilform S-75 or min. 0.0205-inch Tensilform 75 Min. 200 psi, min. 2-inch B1, 62, 63 or B7 ES FM-90 or OMG CR . i and 16-inch o.c. n two, One or more BP- SBS-AA -37.5 thick Celcore BPF equally spaced, staggered AA, SBS-AA at max. 5 ft spans or rows in the field of the sheet structural concrete 7-inch o.c. in a 3-inch lap LWC-16 Min. 22 ga., type B steel at max 5 ft spans or Min. 200 psi, min. 2-inch Bi through B12 ES FM-90 or OMG CR and 7-inch o.c. in two, One or more BP- SBS-AA -45.0 thick Celcore BPF equally spaced, staggered AA, SBS-AA structural concrete rows in the field of the sheet 9-inch o.c. in a 3-inch lap LWC-17 Min. 26 ga., type HF steel at max 5 ft spans or Min. 225 psi, min. 2-inch Bl, 82, B3, 64, 67, B8, B10, B11 OMG CR BPF and 9-inch o.c. in two, One or more BP- SBS-AA -45.0 thick Celcore MF equally spaced, staggered AA, SBS-AA structural concrete or B12 rows in the field of the sheet 7-inch o.c. in a 3-inch lap LWC-18 Min. 22 ga., type B steel at max 6 ft spans or Min. 225 psi, min. 2-inch Bl, B2, B3, 64, B7, 88, BSO, Bil OMG CR BPF and 14-inch o.c. in two, One or more BP- SBS-AA -45.0 thick Celcore MF equally spaced, staggered AA, SBS-AA structural concrete or 612 rows in the field of the sheet 9-inch o.c. in a 3-inch lap LWC-19 Min. 22 ga., type B steel at max 6 ft spans or Min. 225 psi, min. 2-inch BS, 132, 133, 64, B7, B8, B10, Bll OMG CR BPF and 9-inch o.c. in two, One or more BP- SBS-AA -45.0 structural concrete thick Celcore MF or 612 equally spaced, staggered AA, SBS-AA rows in the field of the sheet Min. 26 ga., type HF steel Min. 200 psi, min. 2-inch 9-inch o.c. in a 4-inch lap One or more BP - LWC-20 at max 5 ft spans or min. 22 type B steel at thick Celcore or min. 225 B2 or B11 Simplex Turbo Tube- and 12-inch o.c. in two, AA, SBS-AA, SBS- ,SBS-TA, -45.0 ga., max 6 ft spans or psi, min. 2-inch thick Lok equally spaced, staggered TA or APP-TA or APP or APP-TA Celcore MF rows in the field of the sheet structural concrete Min. 26 ga., type HF steel Min. 200 psi, min. 2-inch P B2 9-inch o.c. in a 4-inch lap One or more SBS- at max 5 ft spans or min. thick Celcore or min. 225 Simplex Turbo Tube- and 12-inch o.c. in two, SA, SBS-TA or SBS-SA, APP-SA, -45.0 LWC-21 22 ga., type B steel atP psi, min. 2-inch thick film (with poly-film Lok equal) spaced, staggered APP-TA SBS-TA or APP-TA max 6 ft spans or Celcore MF to surface) rows in the field of the sheet n structural concrete Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 20 of 30 M .. TABLE 4C: LIGHTWEIGHT CONCRETE DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER Roof Deck (See Note 1, Page 1) Base Sheet (See Note A below) Roof Cover System Type MOP (psf) No. Structural Deck Lightweight Concrete (See Note A) Fasteners Attach Ply Cap Min. 22 ga., type B steel Min. 225 psi, min. 2-inch 9-inch o.c. in a 4-inch lap and 18-inch o.c. in two, One or more BP- SBS-AA, SBS-TA, LWC-22 at max 5 ft spans or thick Celcore MF Ell or B2 ES Twin Loc-Nail equally spaced, staggered AA, SBS-AA, SBS- or APP-TA -45.0 structural concrete rows in the field of the sheet TA or APP-TA Min. 22 ga., type B steel Min. 225 psi, min. 2-inch 82 9-inch o.c. in a 4-inch lap and 18-inch o.c. in two, One or more SBS- SBS-SA, APP-SA, LWC-23 at max 5 ft spans or thick Celcore MF (with poly -film ES Twin Loc-Nail equally spaced, staggered SA, SBS-TA or SBS-TA or APP-TA -45.0 structural concrete top surface) rows in the field of the sheet APP-TA 8-inch o.c. in a 4-inch lap Min. 22 ga., type B steel Min. 300 psi, min. 2-inch B2 ES FM-90 and 8-inch o.c. in three BP -AA, SBS-AA, SBS-AA, SBS-TA, -60.0 LWC 24 at max 5 ft spans or thick Celcore MF equally spaced, staggered SBS-TA or APP-TA or APP-TA structural concrete center rows Min. 22 ga., type B steel Min. 300 psi, min. 2-inch B2 8-inch o.c. in a 4-inch lap and 8-inch o.c. in three One or more SBS- SBS SA, APP-SA, LWC-25 at max 5 ft spans or thick Celcore MF (with poly -film ES FM-90 equally spaced, staggered SA, SBS-TA or SBS-TA or APP-TA -60.0 structural concrete top surface) center rows APP-TA 7-inch o.c. in a 3-inch lap LWC-26 Min. 22 ga., type B steel at max 5 ft spans or Min. 300 psi, min. 2-inch B1 through B12 ES FM-90 or OMG CR and 7-inch o.c. in two, One or more BP- SBS-AA -75.0 thick Celcore BPF equally spaced, staggered AA, SBS-AA structural concrete rows in the field of the sheet Min. 22 ga., type B steel Min. 300 psi, min. 2-inch 10-inch o.c. in a 4-inch lap and 10-inch o.c. in three (Optional) BP -AA, SBS-AA, SBS-TA, LWC-27 at max 5 ft spans or thick Celcore MF Elastobase Poly ES FM-260 equally spaced, staggered SBS-AA, SBS-TA APP-TA -90.0 structural concrete center rows or APP-TA ELASTIZELL CELLULAR LIGHTWEIGHT INSULATING CONCRETE: Min. 0.0179-inch Tensilform S-75 or min. Min. 200 psi, min. 2-inch ES FM-90 or OMG CR 7.5-inch o.c. in a 3-inch lap and 7.5-inch o.c. in two, One or more BP- SBS-AA, SBS-TA, LWC-28 0.0205-inch Tensilform 75 thick Elastizell Range II B1 through B12 BPF equally spaced, staggered AA SBS-AA, SBS- or APP-TA -30.0 at max. 5 spans or rows in the field of the sheet TA, or APP-TA structural concrete Min. 0.0179-inch B2 7.5-inch o.c. a 3-inch lap One or more SBS- LWC-29 Tensilform S-75 or min. 0.0205-inch Tensilform 75 Min. 200 psi, min. 2-inch (with poly -film ES FM-90 or OMG CR BPF and 7.5-inch o.c. in two, equally spaced, staggered SA, SBS-TA or SBS-SA, APP-SA, SBS-TA or APP-TA -30.0 at max. 5 ft spans or thick Elastizell Range II top surface) rows in the field of the sheet APP-TA structural concrete Min. 22 ga., type B steel Min. 200 psi, min. 2-inch ES FM-90 or OMG CR 7-inch o.c. in a 3-inch lap and 7-inch o.c. in two, One or more BP- AA, SBS-AA, SBS- SBS-AA, SBS-TA, -45.0 LWC-30 at max 5 ft spans or thick Elastizell Range II Bl through B12 BPF equally spaced, staggered TA, or APP-TA or APP-TA structural concrete rows in the field of the sheet Min. 22 ga., type B steel Min. 200 psi, min. 2-inch B2 ES FM-90 or OMG CR 7-inch o.c. in a 3-inch lap and 7-inch o.c. in two, One or more SBS- SA, SBS-TA or SBS-SA, P -45.0 LWC-31 at max 5 ft spans or thick Elastizell Range II (with poly -film BPF equal) spaced, staggered APP-TA r P-T SBS-TA or APP-TA structural concrete top surface) n rows in the field of the sheet Exterior Research and Design, LLC. d/b/a Trinity IERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 21 of 30 F�1-0 '\\JTRINITYIERD TABLE 4C: LIGHTWEIGHT CONCRETE DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER Roof Deck (See Note 1, Page 1) Base Sheet (See Note A below) Roof Cover System M DP No. Structural Deck Lightweight Concrete Type Fasteners Attach Ply Cap (Psf) (See Note A) Min. 22 ga., type B steel 9-inch o.c. in a 4-inch lap One or more BP- SBS-AA, SBS-TA, LWC-32 at max S ft spans or Min. 200 psi, min. 2-inch B2 or Bll Simplex Turbo Tube- and 12-inch o.c. in two, AA, SBS-AA, SBS- SBS-SA, APP-TA -45.0* concrete thick Elastizell Range II Lok equally spaced, staggered TA, SBS-SA, or ' or APP-SA structural rows in the field of the sheet APP-TA Min. 350 psi, min. 2-inch Min. 22 ga., type B steel thick Elastizell with Zell- 6-inch o.c. in a 4-inch lap SBS-AA, SBS-TA, LWC-33 at max 5 ft spans or Crete Fibers, supple- B2 ES Twin Loc-Nails and 6-inch o.c. in three, One or more BP- SBS-SA, APP-TA -60.0 structural concrete mentally attached with (min. 1.8-inch) equally spaced, staggered AA or SBS-AA or APP-SA Roofgrip #21 and 3-inch rows in the field of the sheet plates at 1 per 8 ft2 Min. 350 psi, min. 2-inch thick Elastizell with Zell- B2 6-inch o.c. in a 4-inch lap Min. 22 ga., type B steel Crete Fibers, supple- ES Twin Loc-Nails and 6-inch o.c. in three, SBS-SA, SBS-TA SBS-SA, APP-SA, -60.0 LWC-34 at max 5 ft spans or mentally attached with (with ol py-film (min. 1.8-inch) equally spaced, staggered or APP-TA SBS-TA or APP-TA structural concrete Roofgrip #21 and 3-inch top surface) rows in the field of the sheet plates at 1 per 8 ft2 MEARLCRETE CELLULAR LIGHTWEIGHT INSULATING CONCRETE: 7.5-inch o.c. in a 3-inch lap LWC-35 Min. 24 ga., type B steel at max 5 ft spans or Min. 200 psi, min. 2-inch Bl through B12 ES FM-90 or OMG CR and 10-inch o.c. in two, One or more BP- SBS-AA -30.0 thick Mearlcrete BPF equally spaced, staggered AA, SBS-AA structural concrete rows in the field of the sheet Min. 22 ga., type B steel Min. 300 psi, min. 2-inch ES FM-90 or OMG CR 7-inch o.c. in a 4-inch lap and 7-inch o.c. in two, One or more BP - AA, SBS- SBS-AA, SBS-TA, -45.0 LWC-36 at max 5 ft spans or thick Mearlcrete B3, 82 or 612 BPF equally spaced, staggered r APP-TA , TA, or PP - or APP-TA structural concrete rows in the field of the sheet Min. 22 ga., type B steel Min. 300 psi, min. 2-inch B2 ES FM-90 or OMG CR 7-inch o.c, in a 4-inch lap and 7-inch o.c. in two, One or more SBS- SA, SBS-TA or SBS-SA, APP-SA, -45.0 LWC-37 at max 5 ft spans or thick Mearlcrete (with poly -film BPF equally spaced, staggered a APP-TA SBS-TA or APP-TA structural concrete top surface) rows in the field of the sheet Min. 22 ga., type B steel Min. 300 psi, min. 2-inch B1, B2, 63, B4, 9-inch o.c. in a 4-inch lap and 9-inch o.c. in two, One or more BP - SBS-AA, SBS-TA, LWC-38 at max ft spans or thick Mearlcrete B7, B8 or Bll Simplex Base-Lok equally spaced, staggered AA, , SBS- or APP-TA -45.0 l concrete structural rows in the field of the sheet or APP-TA TA, or PP - Min. 22 ga., type B steel Min. 300 psi, min. 2-inch 82 9-inch o.c. in a 4-inch lap and 9-inch o.c. in two, One or more SBS- SBS-SA, APP-SA, LWC-39 at max 5 ft spans or p thick Mearicrete poly -film (with py Simplex Base-Lok equally spaced, staggered equally SA, SBS-TA or SBS-TA or APP-TA -45.0 structural concrete top surface) in the field of the sheet APP-TA Min. 22 ga., type B steel Min. 300 psi, min. 2-inch Simplex Turbo Tube- 9-inch o.c. in a 4-inch lap and 12-inch o.c. in two, One or more BP- AA, SBS-AA, SBS- SBS-AA, SBS-TA, LWC-40 at max 5 ft spans or thick Mearlcrete B2 or BSS Lok equally spaced, staggered TA, SBS-SA, or SBS-SA, APP-TA or APP-SA -45.0 structural concrete rows in the field of the sheet APP-TA Min. 22 ga., type B steel Min. 300 psi, min. 2-inch Bl, B2, 63, B7 or ES FM-90 or OMG CR 7-inch o.c. in a 4-inch lap and 7-inch o.c. in two, One or more BP- AA, SBS-AA, SBS- , SBS-AA, SBS-TA -52.5 LWC-41 at max.5 ft.spans or thick Mearlcrete -Bll BPF equally spaced, staggered - TA, or APP-TA - -or APP_-TA structural concrete rows in the field of the sheet Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization *9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 22 of 30 dill a. TABLE 4C: LIGHTWEIGHT CONCRETE DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER Roof Deck (See Note 1, Page 1) Base Sheet (See Note A below) Roof Cover System Type MOP (psf) No. Structural Deck Lightweight Concrete (See Note A) Fasteners Attach Ply Cap Min. 22 ga., type B steel Min. 300 psi, min. 2-inch B2 ES FM-90 or OMG CR 7-inch o.c. in a 4-inch lap and 7-inch o.c. in two, One or more SBS- SBS-SA, APP-SA, LWC-42 at max 5 ft spans or thick Mearlcrete (with poly film BPF equally spaced, staggered a SA, SBS-TA or SBS TA or APP-TA -52.5 structural concrete top surface) rows in the field of the sheet APP-TA Min. 22 ga., type B steel Min. 300 psi, min. 2-inch 9-inch o.c. in a 4-inch lap and 12-inch o.c. in two, One or more BP- SBS-AA, SBS-TA, LWC-43 at max 5 ft spans or thick Mearlcrete B1, B2, B3 or B4 Simplex Base-Lok equally spaced, staggered AA, SBS-AA, SBS- or APP-TA -52.5 structural concrete rows in the field of the sheet TA, or APP-TA Min. 22 ga., type B steel Min. 300 psi, min. 2-inch B2 9-inch o.c. in a 4-inch lap and 12-inch o.c. in two, One or more SBS- SBS-SA, APP-SA, LWC-44 at max 5 ft spans or thick Mearlcrete (with poly -film Simplex Base-Lok equally spaced, staggered SA, SBS-TA or SBS-TA or APP-TA -52.5 structural concrete top surface) rows in the field of the sheet APP-TA A. Base Sheets options are coded as follows: ➢ Bl: Polyglass G2 Base; ➢ B2: Elastobase or Elastobase Poly; ➢ B3: GAFGLAS #75; ➢ B4: Stratavent Eliminator Venting Base Sheet (Nailable); ➢ B5: GAFGLAS Ply 4; ➢ B6: GAFGLAS FlexPly 6; ➢ B7: JM Perma Ply No. 28; ➢ B8: JM Vensulation; ➢ B9: JM GlasPly IV; ➢ B10: JM GlasPly Premier; ➢ B11: Tamko Glass -Base; ➢ B12: Tamko Vapor -Chan Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 23 of 30 TABLE SA: CEMENTITIOUS WOOD FIBER DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System Base Insulation Layer Top Insulation Layer Roof Cover MDP (psf) Type Attach Type Attach Base Ply Cap No. Deck Min. 0.25-inch Min. 1.5-inch DensDeck, DensDeck (Optional) One or CWF-1 Min. 2.5-inch Tectum ACFoam II, ISO 95+GL, H-Shield, D-IS or OB500 Prime, SECUROCK Gypsum -Fiber Roof D-IS or OB500 BP -AA, SBS- more BP -AA, SBS- SBS-AA, SBS- -45.0 Plank or Tectum LS Plank Polytherm, Board or min. 0.5- AA AA, SBS-TA or APP- TA, APP-TA ENRGY-3 inch Structodek HD TA Fiberboard Min. 1.5-inch Min. 0.25-inch ACFoam II, ISO DensDeck, DensDeck SBS-TA, (Optional) One or SBS-TA, SBS- CWF-2 Min. 2.5-inch Tectum 95+GL, H-Shield, D-IS or OB500 Prime, SECUROCK D-IS or OB500 SBS-SA or more SBS-TA, SBS- SA, APP-TA, -45.0 Plank or Tectum LS Plank Polytherm, Gypsum -Fiber Roof APP-TA SA or APP-TA APP-SA ENRGY-3 Board Min. 0.25-inch Min. 1.5-inch DensDeck, DensDeck (Optional) One or CWF-3 Min. 2.5-inch Tectum ACFoam II, ISO 95+GL, H-Shield, CR-20 Prime, SECUROCK Gypsum -Fiber Roof CR-20 BP -AA, SBS- more BP -AA, SBS- SBS-AA, SBS- -52.5 Plank or Tectum LS Plank Polytherm, Board or min. O.5- AA AA, SBS-TA or APP- TA, APP-TA ENRGY-3 inch Structodek HD TA Fiberboard Min. 1.5-inch Min. 0.25-inch ACFoam II, ISO DensDeck, DensDeck SBS-TA, (Optional) One or SBS-TA, SBS- CWF-4 Min. 2.5-inch Tectum 95+GL, H-Shield, CR-20 Prime, SECUROCK CR-20 SBS-SA or more SBS-TA, SBS- SA, APP-TA, -52.5 Plank or Tectum LS Plank Polytherm, Gypsum -Fiber Roof APP-TA SA or APP-TA APP-SA ENRGY-3 Board Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 24 of 30 "�JTRINITYJE F)o TABLE SB: CEMENTITIOUS WOOD FIBER DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System Anchor Sheet Base Insulation Top Insulation Roof Cover MOP No. Roof Deck Type Fastener Attach Type Attach Type Attach Base Ply Cap (Psi 9-inch o.c. in Min. 1.5-inch Min. 0.25-inch DensDeck, DensDeck (Optional) Min. 2.5-inch Elastobase, ES 4-inch lap and 12-inch o.c. in ACFoam II, ACFoam III, Prime, SECUROCK One or SBS-AA, CWF-5 Tectum Plank or Elastobase Poly, Polyglass Inuldek two, equally ISO95+GL, H- HA Gypsum -Fiber Roof Board, Min. 0.75-inch HA BP -AA, SBS-AA more BP- AA, SBS- SBS-TA, -30.0* Tectum LS Plank G2 Base Loc-Nail spaced, Shield, ENRGY 3, FescoBoard or min. AA, SBS-TA APP-TA staggered Polytherm 0.5-inch Structodek or APP-TA center rows Multi -Max FAA 3, HD Fiberboard 9-inch o.c. in Min. 1.5-inch Elastobase, 4-inch lap and ACFoam II, Min. 0.25-inch (Optional) SBS-TA, Min. 2.5-inch Elastobase ES 12-inch o.c. in ACFoam III, DensDeck, DensDeck SBS-TA, One or SBS-SA, CWF-6 Tectum Plank or Poly, Polyglass Inuldek two, equally ISO95+GL, H HA Prime, SECUROCK HA SBS-SA or more SBS- APP-TA, -30.0* Tectum LS Plank G2 Base Loc-Nail spaced, Shield, ENRGY 3, Gypsum -Fiber Roof APP-TA TA, SBS-SA APP-SA staggered Polytherm or Board or APP-TA center rows Multi -Max FA3, 9-inch o.c, in Min. 1.5-inch Min. 0.25-inch DensDeck, DensDeck (Optional) Elastobase, Simplex 4-inch lap and ACFoam II, Prime, SECUROCK One or Min. 2.5-inch Elastobase Base-Lok 18-inch o.c. in ACFoam III, Gypsum -Fiber Roof BP -AA, more BP- SBS-AA, CWF-7 Tectum Plank or Poly, Polyglass or ES two, equally I5O95+GL, H- HA Board, Min. 0.75-inch HA SBS-AA AA, SBS- SBS-TA, -45.0* Tectum LS Plank G2 Base Twin Loc- spaced, Shield, ENRGY 3, FescoBoard or min. AA, APP-TA Nail staggered Polytherm or inch Structodek P-TA or APP-TA center rows Multi -Max FA3, HD Fiberboard HD 9-inch o.c. in Min. 1.5-inch Elastobase, Simplex 4-inch lap and ACFoam II, Min. 0.25-inch (Optional) SBS-TA, Min. 2.5-inch Elastobase Base-Lok 18-inch o.c. in ACFoam III, DensDeck, DensDeck SBS-TA, One or SBS-SA, CWF-8 Tectum Plank or Poly, Polyglass or ES two, equally ISO95+GL, H- HA Prime, SECUROCK HA SBS-SA or more SBS- APP-TA, -45.0* Tectum LS Plank G2 Base Twin Loc- spaced, Shield, ENRGY 3, Gypsum -Fiber Roof APP-TA TA, SBS-SA APP-SA Nail staggered Polytherm or Board or APP-TA center rows Multi -Max FA3, TABLE SC: CEMENTITIOUS WOOD FIBER DECKS — NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System Base Insulation Layer Top Insulation Layer Roof Cover No. Roof Deck Type Fasteners Attach Type Attach Base Ply Cap MDP (psf) OMG N.T.B. Plate (Optional if (Optional if using Min. 2.5-inch Tectum Min. 2-inch H- with N.T.B. Magnum Min. 0.5-inch using Ply) AA Base) One or SBS-AA, CWF-9 Plank or Tectum LS Shield or or TruFast TL 3 in. 1 per 4 ftz Structodek HD HA BP -AA, SBS more BP -AA, SBS- SBS-TA, -45.0* Plank Polytherm Plate with TL Fiberboard , AA, SBS-TA or APP-TA Fastener APP-TA Exterior Research and Design, LLC, d/b/a TrinityjERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 25 of 30 TABLE SD: CEMENTITIOUS WOOD FIBER DECKS — NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System Roof Deck Base Insulation Top Insulation Layer Roof Cover MDP (Psi Type Fasteners Attach Base Ply Cap No. Layer (Optional) One or Min. 0.25-inch DensDeck, (Optional if using Min. 2.5-inch more layers, any DensDeck Prime or SECUROCK ES Twin Lbedm is (min. a (Optional if AA Base) One or SBS-AA, CWF-10 Tectum Plank or combination, loose Gypsum -Fiber Roof Board or 1-inch embedment) 1 per 2 ft using AA Ply) more BP -AA, SBS- SBS-TA, -45.0* Tectum LS Plank laid min. 0.5-inch Structodek HD BP -AAA SBS-AA AA, SBS-TA or APP-TA Fiberboard APP-TA TABLE SE: CEMENTITIOUS WOOD FIBER DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Base Sheet Roof Cover No. Roof Deck Base Fasteners Attach Ply Cap MOP (psf) Min. 2.5-inch Elastobase, Elastobase Poly, Polyglass G2 9-inch o.c. in 4-inch lap and 12- (Optional) One or more BP -AA, SBS-AA, SBS- CWF-11 Tectum Plank or Base ES Inuldek Loc-Nail inch o.c. in two, equally spaced, SBS-AA, SBS-TA TA, APP-TA -30.0* Tectum LS Plank staggered center rows or APP-TA Min. 2.5-inch Elastobase, Elastobase Poly, Polyglass G2 Simplex Base-Lok or ES 9-inch o.c. in 4-inch lap and 18- inch o.c. in two, equally spaced, (Optional) One or more BP -AA, SBS-AA, SBS- -45.0 * CWF-12 Tectum Plank or Base Twin Loc-Nails SBS-AA, SBS-TA TA, APP-TA Tectum LS Plank staggered center rows or APP-TA Exterior Research and Design, LLC. d/b/a TrinityjERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 26 of 30 TABLE 6A: GYPSUM DECKS — REROOF (Tear -Off) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System Base Insulation Layer Top Insulation Layer Roof Cover Deck MDP (psf) Type Attach Type Attach Base Ply Cap No. Min. 1.5-inch (Optional) additional Existing, sound poured ACFoam II, ENRGY 3 layers(s) of base (Optional) One or SBS-SA, APP- G 1 gypsum or gypsum plank or H-Shield or min. 2.0 pcf, ASTM C578 OB500 insulation and/or min. 0.25-inch OB500 SBS-SA more SBS-SA, SBS- SA, -112.5 deck expanded SECUROCK Gypsum- TA or APP-TA PP -TA or APP-TA polystyrene Fiber Roof Board (Optional) additional Existing, sound poured Min. 1.5-inch ACFoam II, ENRGY layers(s) of base insulation and/or (Optional) One or SBS-SA, APP- G-2 gypsum or gypsum plank 3, H-Shield or Multi- M-OSFA min. 0.25-inch M-OSFA SBS-SA more SBS-SA, SBS- SA, SBS-TA -202.5 deck Max FA3 SECUROCK Gypsum - TA or APP-TA or APP-TA Fiber Roof Board (Optional) additional Existing, sound poured Min. 1.5-inch, min. layers of base insulation and/or (Optional) One or SBS-SA, APP- G-3 gypsum or gypsum plank 2.0 pcf EPS insulation CR-20 min. 0.25-inch CR-20 SBS-SA more SBS-SA, SBS- SA, SBS-TA -240.0 deck board SECUROCK Gypsum - TA or APP-TA or APP-TA Fiber Roof Board Min. 0.2S-inch (Optional if (Optional if using AA Existing, sound poured DensDeck, DensDeck using AA Base) One or more SBS-AA, SBS- G-4 gypsum or gypsum plank Prime or SECUROCK CR-20 None N/A Ply) BP -AA, BP -AA, SBS-AA, TA, APP-TA -245.0 deck Gypsum -Fiber Roof SBS-AA SBS-TA or APP-TA Board Min. 1.5-inch (Optional) additional Existing, sound poured ACFoam II, ACFoam layers(s) of base insulation and/or (Optional) One or SBS-SA, APP- G-5 gypsum or gypsum plank III, ENRGY 3, H- CR-20 min. ch CR-20 SBS-SA more SBS-SA, SBS- SA, SBS-TA -257.5 deck Shield, H-Shield CG ROCK Gypsum - SECUROCK Gypsum - TA or APP-TA or APP-TA or Multi -Max FA3 Fiber Roof Board Exterior Research and Design, LLC. d/b/a TrinityjERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-S9166 Appendix 1, Page 27 of 30 TABLE 6B: GYPSUM DECKS — REROOF (Tear -Off) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER Anchor Sheet Base Insulation Top Insulation Roof Cover MDP System No. Roof Deck Type Fast Attach Type Attach Type Attach Base Ply Cap (Psf) sener 9-inch o.c. in Min. 1.5-inch Min. 0.25-inch DensDeck, DensDeck (Optional) Existing, sound Elastobase, 4-inch lap and 18-inch o.c. in ACFoam II, ACFoam III, , PrimeSECUROCK One or SBS-AA, G-6 poured gypsum or Elastobase ES FM-45 two, equally ISO H- HA Gypsum -Fiber Roof HA BP -AA, more BP- SBS-TA, -30.0* gypsum plank Poly, Polyglass or FM-60 spaced, Shield, EN RGY 3, Shield, Board, Min. 0.75-inch SBS-AA AA, SBS- APP-TA deck G2 Base staggered Polytherm or FescoBoard or min. AA, SBS-TA center rows Multi -Max FA3, 0.5-inch Structodek or APP-TA HD Fiberboard 9-inch o.c. in Min. 1.5-inch Min. 0.25-inch DensDeck, DensDeck (Optional) Existing, sound Elastobase, ES FM-75 4-inch lap and 18-inch o.c. in ACFoam II, ACFoam III, Prime, SECUROCK One or SBS-AA, G-7 poured gypsum or Elastobase or FM-90 two, equally ISO95+GL, H- HA Gypsum -Fiber Roof HA BP -AA, more BP- SBS-TA, -45.0* gypsum plank Poly, Polyglass or Twin spaced, Shield, ENRGY 3, Board, Min. 0.75-inch SBS-AA AA, SBS- APP-TA deck G2 Base Loc-Nails staggered Polytherm or FescoBoard min. AA, SB _TA center rows Multi -Max FA3, uc HD inch Structodek HD Fiberboard or APP-TA PP -TA TABLE 6C: GYPSUM DECKS — REROOF (Tear -Off) or RECOVER SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System Roof Deck Base Insulation Top Insulation Layer Roof Cover MDP (psf) Type Fasteners Attach Base Ply Cap No. Layer Existing sound (Optional) One or Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK (Optional if (Optional if using AA Base) One or SBS-AA, G-8 poured gypsum more layers, any Gypsum -Fiber Roof Board or ES Twin Loc-Nails (min. 1 per 2 ftZ using AA Ply) more BP -AA, SBS- SBS-TA, -45.0* or gypsum plank combination, loose min. 0.5-inch Structodek HD 1-inch embedment) BP -AA, SBS-AA AA, SBS-TA or APP-TA deck laid Fiberboard APP-TA TABLE 6D: GYPSUM DECKS — REROOF (Tear -Off) SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Base Sheet Roof Cover MDP No. Roof Deck Base Fasteners Attach Ply Cap (psf) G-9 Existing sound poured gypsum or Elastobase, Elastobase Poly, Polyglass G2 ES FM-45 or FM-60 9-inch o.c. in 4-inch lap and 18- inch o.c. in two, equally spaced, (Optional) One or more BP -AA, SBS-AA, SBS- -30.0* gypsum plank deck Base staggered center rows SBS-AA, SBS-TA or APP-TA TA, APP-TA Existing sound Elastobase, Elastobase Poly, Polyglass G2 ES FM-75 or FM-90 or 9-inch o.c. in 4-inch lap and 18- inch o.c. in two, equally s aced, (Optional) One or more BP -AA, SBS-AA, SBS- -45.0* G-10 poured gypsum or gypsum plank deck Base Twin Loc-Nails p staggered center rows SBS-AA, SBS-TA TA, APP-TA or APP-TA Exterior Research and Design, LLC. d/b/a TrinityjERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 28 of 30 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System Base Insulation Layer Top Insulation Layer Roof Cover MDP No. Substrate Type Attach Type Attach Base Ply Cap (psf) (Optional) additional Existing layers(s) of base (Optional) One or SBS-SA, APP- R-1 asphaltic Min. 1.5-inch Multi -Max FA3 D-IS insulation and/or min. D-IS SBS-SA more SBS-SA, SA, SBS-TA or -67.5 roof 0.25-inch SECUROCK SBS-TA or APP-TA APP-TA Gypsum -Fiber Roof Board (Optional) additional Existing Min. 1.5-inch ACFoam II or layers(s) of base (Optional) One or SBS-SA, APP- R-2 asphaltic ENRGY 3 or min. 2.0 pcf EPS D-IS insulation and/or min. D-IS SBS-SA more SBS-SA, SA, SBS-TA or -90.0 roof insulation board 0.25-inch SECUROCK SBS-TA or APP-TA APP-TA Gypsum -Fiber Roof Board (Optional) additional Existing layers of base insulation (Optional) One or SBS-SA, APP- R-3 asphaltic Min. 1.5-inch, min. 2.0 pcf EPS OB500 and/or min. 0.25 inch OB500 SBS-SA more SBS-SA, SA, SBS-TA or -120.0 roof insulation board SECUROCK Gypsum -Fiber SBS-TA or APP-TA APP-TA Roof Board (Optional) additional Existing layers(s) of base (Optional) One or SBS-SA, APP- R-4 asphaltic Min. 1.5-inch ACFoam II, OB500 insulation and/or min. OB500 SBS-SA more SBS-SA, SA, SBS-TA or -127.5 roof ENRGY 3 or H-Shield 0.25-inch SECUROCK SBS-TA or APP-TA APP-TA Gypsum -Fiber Roof Board (Optional) additional Existing Min. 1.5-inch ACFoam II, layers(s) of base (Optional) One or SBS-SA, APP- R-5 asphaltic ENRGY 3, H-Shield or Multi -Max M-OSFA insulation and/or min. M-OSFA SBS-SA more SBS-SA, SA, SBS-TA or -157.5 roof FA3 0.25-inch SECUROCK SBS-TA or APP-TA APP-TA Gypsum -Fiber Roof Board Min. 2-inch ACFoam IV, min. 1.5-inch Ultra -Max or Multi -Max (Optional) additional Existing FA-3, min. 1.3-inch ACFoam III layers(s) of base (Optional) One or SBS-SA, APP- R-6 asphaltic or min. 1.0-inch ISO 95+GL, H- CR-20 insulation and/or min. CR-20 SBS-SA more SBS-SA, SA, SBS-TA or -240.0 roof Shield, H-Shield CG or ENRGY 3 0.25-inch SECUROCK SBS-TA or APP-TA APP-TA or min. 2.0 pcf ASTM C578 Gypsum -Fiber Roof Board expanded polystyrene (Optional) additional Existing Min. 2-inch ACFoam II, ENRGY- layers(s) of base (Optional) One or SBS-SA, APP- R-7 asphaltic 3 or ld or min. 2.0 pcf CR-20 insulation and/or min. CR-20 SBS-SA more SBS-SA, SA, SBS-TA or -247.5 roof ASTM 578 expanded C578 0.25-inch SECUROCK SBS-TA or APP-TA APP-TA polystyrene Gypsum -Fiber Roof Board Min. 0.25-inch DensDeck, BP -AA, SBS- (Optional) One or R-8 Existing asphaltic Min. 1.5-inch Multi -Max FA3 D-IS DensDeck Prime or D-IS AA, SBS-TA, more BP -AA, SBS- SBS-AA, SBS- -67.5 SECUROCK Gypsum -Fiber SBS-SA, AA, SBS-TAor TA, orAPP-TA roof Roof Board APP-TA APP-TA Min. 0.25-inch DensDeck, BP -AA, SBS- (Optional) One or Existing ACFoam Min. 1.5-inch ACFoam II or DensDeck Prime or D-IS AA, SBS-TA, more BP -AA, SBS- SBS-AA, SBS- g0.0 R-9 asphaltic ENRGY 3 or min. 2.pcf EPS D-IS SECUROCK Gypsum -Fiber SBS-SA, AA, SBS-TAor TA, or APP-TA roof insulation board Roof Board APP-TA APP-TA Exterior Research and Design, LLC. d/b/a Trinity IERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report P9290.02.08-118 for FL1654-R10 Revision 8: 12/06/2011 Appendix 1, Page 29 of 30 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System Base Insulation Layer Top Insulation Layer Roof Cover No. Substrate Type Attach Type Attach Base Ply Cap MDP (psf) Existing Min. 1.5-inch ACFoam II, Min. 0.25-inch DensDeck, BP -AA, SBS- (Optional) One or R-10 asphaltic ENRGY 3, H-Shield or ISO OB500 DensDeck Prime or OB500 AA, SBS-TA, more BP -AA, SBS- SBS-AA, SBS- -127.5 SECUROCK Gypsum -Fiber SBS-SA, AA, SBS-TAor TA, or APP-TA roof 95+GL Roof Board APP-TA APP-TA BP -AA, SBS- (Optional) One or R-11 Existing asphaltic Min. 1.5-inch ACFoam II, ENRGY 3, AC ld or Multi Max M-OSFA Min. 0.25-inch SECUROCK M-OSFA AA, SBS-TA, more BP -AA, SBS- SBS-AA, SBS- -157.5 Gypsum -Fiber Roof Board SBS-SA, AA, SBS-TAor TA, or APP-TA roof FA3 APP-TA APP-TA Min. 2-inch ACFoam IV, min. 1.5-inch Ultra -Max or Multi -Max Existing FA-3, min. 1.3-inch ACFoam III Min. 0m-Fibernch BP -AA, SBS _ (Optional) One or BP SBS- SBS-AA R-12 asphaltic or min. 1.0-inch ISO 95+GL, H- CR`-20 Roof Board Gypsum -Fiber Roof Board CR-20 AA more -AA, -225.0 roof Shield, H-Shield CG or ENRGY 3 AA or min. 2.0 pcf ASTM C578 expanded polystyrene Min. 2-inch ACFoam IV, min. 1.5-inch Ultra -Max or Multi -Max Existing FA-3, min. 1.3-inch ACFoam III Min. 0.25-inch SECUROCK (Optional) One or R-13 asphaltic or min. 1.0-inch ISO 95+GL, H- CR-20 Gypsum -Fiber Roof Board CR-20 APP-TA more APP-TA APP-TA -232.5 roof Shield, H-Shield CG or ENRGY 3 or min. 2.0 pcf ASTM C578 expanded polystyrene TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE F: NON -INSULATED, BONDED BASE SHEET, BONDED ROOF COVER Roof Cover System No. Deck Primer MOP (psf) Base Ply Cap Existing BP -AA (Optional if using asphalt Basei) BP iAA using R-14 asphaltic roof PG100 applied Ply) SBS-AA, SBS-TA or SBS-AA, SBS-TA, APP-TA -45.0 APP-TA Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report P9290.02.08-R8 for FL1654-R10 Certificate of Authorization #9503 Revision 8: 12/06/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 30 of 30