HomeMy WebLinkAboutSUBMITTED PAPERSDATE: FEES DUE: RECEIPT #: I Permit #: / A 4-
Planning & Development Services Department SC
c p Building & Code Regulation Division By
o 2300 Virginia Avenue S't
Ft. Pierce, FL 34982-5652 LUCie
�s. s_ Tel.772-462-1553 c��n�
APPLICATION FOR ROOF PERMIT
SEE REVERSE SDE FOR INSTRUCTIONS
1. Location/Site Address: 8307 Fort Walton Ave, Fort Pierce, FL 34951
2. Parcel ID Number: 1 301-606-0027-000-2
Office Use
Only
Section
I Township
Range,
Ma Pa a
ZonmLF
I Land Use
nk
3. Description of Project or Work Activity:
4. Total Roof Area (square feet): Z 3 C-�2 5. Roof Pitch: �/J Zr
6. Type of Roof: [ X] Fiberglass Shingle [ ] Concrete Roof Tile [ ] ood Shake / Shingle
[ ] Tar & Gravel [ ] Modified Bitumen [ ] Other
[ X] Product Approval required for all types of Roofing Material (2 Sets)
[ ] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product
Approval attached
** Roof Mitigation per F.S. 553.844 will be required.
7. Owner Information J �p 8. Contractor Information
Name: L' d- FL Reg/Cert #: (-C� 1 ti 1 R R
Address: 8307 Fort Walton Ave County Cert#:�,�
City: Fort Pierce State:
`/ FL
1 /
Zip: 3 4 9 51 Phone: )� q
9. Value of Construction: $ $ 4 , 9 9 7.9 3
Business Name: Atlantic Roofing II
Cell Phone: 772-492-8493
"Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval.
CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all of te information conta' this ap icadon is correct and that all work will be
done in comp ' 1 a;plicabI s re 11atconstruction and zoning.
William Lasky, Jr.
PRINT QUALIFIERS/OWNERS NAME SIGNATURE OF QUALIFI OWNS
STATE OFFLORIDA,COUNTY .,F.��ZIndian River
ACKNOWLEDGEDBEFOR�1'T�.'�_Z9 DAYOF May 20 12,BY William Lasky., Jr.
WHO Is
ME OR HAS
/ / Steven N Cottrell
SIGNATM (,Tir' NOTARY- j Q TYPE OR PRINT NAME OF NOTARY
COMMISSION NUMBER F / / tJ 6C5
S VEN N COTMELL
COMMISSION # EE198W5
EXPIRES May 15, 2016
NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE
FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
Revised 4/26/2010
v l C �i ,off 31b0
I Je
A
Ma310'HllgS QglOPvl
3H.L JO Ad00 1038wo ON 31ib1
V SI S*U IVHI "UN30 Ol SI SIHI
UN100 310nl .LS
volums SO 31ris
9lob'91 Am 83lNdl(3
poonpoiduolleoHlluapl;oadA1 S9988IMMOI991 Zl:.Io.oll&.Iq:,,d;;4:�nleust)
d'uud)
'1'13MU03NOMS
uolle3l;l3uapl pampoid Jo -;�umowl ApeuosJad
paln3axa sem luawtuisul woym;o;legaq uo /Wed (aalsnn'ua:)Lp s•a) A11Joglne;o adA.L ;o aweN
anuaAV u0}isM -4ao3 Lou Jo; Q aauMO se 3 Ag
Z 1-0Z ';oAep --fTslyl aw aJo;aq paspalmou:l3e seM 1ua J1sul sulosaJo; 041
(aow0/allu sNoleusl5)
' .ZaUMO
JaseueW/jau:ld7�P-9111'1/Ja3S}0 p • oy1nV s,aassal Jo s�aump Jo'aassal Jo Jaump;o aJnleusl5)
•;allaq pue aspalmou:I Aw
104saq 841 Ol awl aJe ulaJayl palels sloe; ayi;eyl pue lnawa3UaW wa3;D aollou PulosaJo; agl peal aney I leyl aJel3ap I'/Nn(Jad;o Aiieuad Japun
'1N3 W 3DN3W W OO d0 3DIlON uno k 9NIOHOD3H
HO HHOM 9NIDN31NWOO 3HOi39 A3 NH01 LV NV HO H30 N31 HnOA Him 1lnSNO0'9NIDNVNIi NIV190 Ol ONIM nOA it 'NOIJ33dSNi
1SHIi 3H13HOA39 3lis 90f 3Hl N0031SOd ONV 03OH003H 3a 1snw 1N3W33N3 W WOO 10 33IJ0N V'ALH3dOHd mak 01 S.LN3W3AOHdWI
HOi 33IML 9NIAVd Hn0A NI 1lnS311 NVD ONV'S3J.n1VJS VOIHOIi'£I'£IL NOLL73S'I1HVd'£IL H3ldVHD H3ONn S1N3WAVd 113dOHdWI
03u301SNOD 3HV1N3WIMMOD i0 3DLLON 3H1 10 NOI.LWldX3 3H1H31iV H3NMO 31-L A9 3OVW S1N3WAVd ANV:H3NMO 019NINHVM
(pa01oods sl alep luaia;pp a ssalun 9ulpioowjo alep ayl woJ; JeaA I aq ll! m 1nq'Jopejluo3
ag1 olluawAed Ieug pue uoll3nilsuo3;o ualieldwo3 ay1 aJo;aq aq )Au Aew alep uolleJldxa ag1) :lUawa3Uaww03;0 a3llou;O alep uolleJldx3
:Jaumo Aq paleuslsep Algua Jo uosiad 10 Jagwnu auoyd
•saln1e15 epPoli'(q) (i)£T EIZ uoI133S ul papinoid se 031ioN s iouan
agl;o Ado a anlanj of ;o saleuslsap Jaump';lasiay Jo;Iaswlg of uolllppe ul
:ssaJppV
:JagwnN auoyd :aweN
salnleiS eppoli''L(e) (I)€I'€IZ
uoll3aS M Papinoid se panics aq Aew s3uawn3op Ja410 Jo s83llou wogm uodn Jaumo Aq poleuslsop eplJoli;o 03e1S 041 ulgi!m suosJad
:ssaJppe sjapual
:JagwnN auoyd :aweN Japual
:Jagwnu auoyd auON :ssaJppe pue aweN
S :puoq;o lunowV :(pay3eue sl puoq ivawAed 84110 Adm e'algnlldde;l) AiainS
E 6 V —76 — LL :JagwnNauoyd r!3 3LIORDEL 0.19A 'aAV LDJEV OZOV:SSOJPPVJOPeJIUQ:)
-DUI [goEag 0.19A 30 II uT3oog oF:IuEi4V :aweNsJoPeJluoO
:(anoge palsll Jaump woJ;luaJaHlp JI) Japlogallll aldwls aa;;o ssaJppe pue aweN
:A1Jadoid ul lsaialul
ssaJppV
Aa8Mo7 g 2ST'I Aa=;;ar Z waTT ITM aweN
:luauianoidwl 841 Jo; p0139J1u03 aassal ag1A uollewJo;ul vassal Jo uollewJo;ul Jaumo
Joog aZ uTgS aoej ag 11 aAowag :luawanoidwl;ouolidlnsopleJauag
5L32g pooMaxEZ JanuaAV UOgTPM ga03 LO£9'(algellene;lssaippelaoilspue):AZJadOidlouolldlosealesal
•luawa3uawwoD 10 031ION s(yl ul papinad sl uollewJo;ul 9ulmollo; ayl
'sainimS eplJoli'£IL JaidegD 411m a3uepl = ul pue'A1Jadoid leaf upiao of apew aq Illm ivawamudwl Imp aollou sank AgaJaypouslsiapun agl
Z-00 - Z - - 'oNOI1OAXel
1N3W3:)N3WW0:) d0 DUON
apnl•1S;oA4unoD eppoli;oalelS
'ON 1pwad
AId 9Z:Z, ZT0Z/L0/90 PePaOOag 'LZ6Z asvd L61. DOH UO LOTZTLE # HIIa
ALLNnOO SIOM INNS - IMOO IMOU10 3HS av A=0 'HSIYIS '3 Hd3SOP
Property Appraiser - St.Lucie '- inty, FL Page 1 of 1
PROPERTY RECORD CARD
William L Jeffrey Record: 1 of 1
«Prev Next» Spec.Assmnt Taxes Exemptions Permits Home Print
Property Identification
CIE
Site Address: 8307 Fort Walton Av
Sec/Town/Range: 02 :34S :39E
ParcellD: 1301-606-0027-000-2
Account*: 1437 v� 4
Map ID:
Land Use: SF Res
RS-4
Zoning: RS-4
CitylCnty: St Lucie County
Ownership and Mailing
Legal Description
Owner: William L Jeffrey Lisa R Lowery LAKEWOOD PARK -UNIT 6- BLK 57 LOT27 (MAP 13/02S) (OR 555-
Address: 8307 Fort Walton Ave
382)
Fort Pierce FL 34951-1397
Sales Information
Assessment 2011 Final Total Land and Building
Date Price Code Deed
Book/Page 2011 Final: 39100 Land Value: 4800 Acres: 0.23
8/1/1987 52500 00 CV
0555 / 0382 Assessed: 39100 Building Value: 34300
12/1/1986 0 01 CV
0547 / 2079 Ag.Credit: 0 Finished Area: 1088 SgFt
12/1/1986 4000 00 CV
0526 / 1327 Exempt: 25000
Taxable: 14100
Taxes: 286.9
BUILDING INFORMATION
�1
Exterior Features
View:
-
RoofCover:
FS - Fibrglss Shg
RoofStruct:
HP - Hip
ExtType:
HD+ - HD+
YearBit:
1987
Frame:
-
Grade:
D+ - D+
EffYrBlt:
1987
PrimeWall:
WS - Wood/Sheath
StoryHght:
0010 -1 Story
No.Units:
1
SecWall:
-
Interior Features
BedRooms:
2
Electric:
MX - MAXIMUM
PrmintWall:
DW - Drywall
FullBath:
2
HeatType:
FHA - FrcdHotAir
AvgHt/FI:
STD
1/213ath:
0
HeatFuel:
ELEC - Electric
Prm.Flors:
CU - Carpet
%A/C:
100
%Heated:
100
%Sprinkled:
0
Special Features and Yard Items
Land Information
Type Y!S
Qty. Units Qual.
Cond. YrBlt.
No. Land Use
Type
Measure Depth
1 0100-SF Res
BI-Front Ft
75 131
THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED.
http://www.paslc.org/paslc/Prc.asp?prclid=l30160600270002 6/8/2012
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34982
772-462-2165 or 772-462-2172
Fax: 772-462-6443
ROOF INSPECTION AFFIDAVIT
Re: Permit #-
I, William Lasky, _Jr. _ . licensed as a(n)Contractor*/Fngineer/Architect
(Please print name & circle license type) *FS468 Building Inspector
*General, Building, Residential or Rooflng Contractor or any individuuf ce0ad under 468 F.S. to make Such an Inspection.
On or about Ug • I •r7 D 126 ,1 did personally inspect the roof deck nailing
(Date)
work at: 8307 Fort Walton Ave.
(Job site address)
Based upon that examination l have determined the installation was done according to the Hurricane
Mitigation Retrofit Manual (Based on 554.1844 F.S.)
r
signature and Seal
STATE OF FLORIDA
COUNTYOF IL1c32an River
CCC1326188
License #
Sworn to and subscribed before me this day of �x.> 20J
byWiiliam Lasky, Jr •.. Who is personally kn wn to me�atpxtpol
xxxxxxxxxxxxXXXXXxxx=td s
Notary Public, State of Florida 81MU N COTMELL
MY COUMNION 6 691'1IMS
Signature of Notary: $�� ts1Q4e
Commission Number. 6,45�- (Se
En 02/19/2012
9��Yf
ATLANTIC ROOFING II
OF VERO BEACH, INC.
Lit. # CCC1326188
Ph:772-492-8493 Fax:772-257-5740
Tuesday, May 29, 2012
TO: Lisa Lowery
8307 Fort Walton Avenue
Fort Pierce, FL 34951
RE: Re -Roof Residence
4020 43`d Ave
Vero Beach, FI 32960
E-Mail: wliatrCeDaol.com_
We propose the following furnished and installed:
** Remove existing roofing, haul all related debris from job site
** Nail off plywood to code
** Install PolyGlass PolyStick IR-X vapor barrier
** Install 130 MPH Dimesional Shingles (color to be determined by customer) using ring
shank roofing nails.
** White galvalume flashing and new lead plumbing jacks.
** Dade County approved Suntek Skylite
** Lemanco Shingle over ridge vent
** Included in price is permit and inspections
TOTAL MATERIAL AND LABOR $ 4,997.93
** 50% DEPOSIT 50% UPON COMPLETION **
All material is guaranteed to be as specified. All work to be completed in a workmanlike manner according to
standard practices. Any alteration or deviation from above specifications involving extra cost will be executed only
upon written orders, and will become an extra charge over and above. Owner is to carry fire, tornado and other
necessary insurance. Our workers are fully covered by Workers Compensation Insurance.
With the consent of the Bu er an rotten lumber or unsuitable substrate materials which are disclosed as the
work grogresses and which are not specifically mentioned in this Proposal and agreement will be replaced or made
suitable and any additional costs (Cost Plus 1091o) will be added to the contract.
Authorized
FROM ISSUANCE
05/29/2012
ACCEPTANCE of PROPOSAL
The above specifications, prices and conditions are satisfactory and hereby accepted. You are authorized to do the
work as specified.
Accepted by:
Date of Acceptance:N2
Florida Building Code Onlin ' Page 1 of 2
/'
b'
(�I a Depa "flent BCIS Home' Log In User Registration Hot Topics Submit Surcharge is Stats & Facts E Publications € FBC Staff j; BCIS Site Map !i Links Search
Busines
P Ofiess� Product Approval
�}ppC ;USER: Public User
gulation
rii!!��±i}iI!nrr:�l Product Approval Menu > Product or Aoolication Search > Aoolication List > Applfcation Detail
�
FL # FL10674-R6 a
Application Type Revision
Code Version 2010
Application Status Approved
Comments 0Archived
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkw
Toledo, OH 43659
(740)404-7829
greg.keeler@owenscorning.
99
Authorized Signature Greg Keeler
greg.keeler@owenscorning.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Corning PKWY
Toledo, OH 43659
mel.sancrant@owenscornig.com
mel.sancrant@owenscornig.com
Quality Assurance Representative
Address/Phone/Email v
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who
developed the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Robert J.M. Nieminen
PE-59166
Underwriters Laboratories Inc.
09/26/2014
John W. Knezevich, PE
Z' Validation Checklist - Hardcopy Received
FL10674 R6 COI Trinity ERD CI - Nieminen.odf
Standard
ASTM D3161, Class F
ASTM D3462
ASTM D7158, Class H
Year
2006
2007
2007
1�11rx•//xxrxxnxr flnrirlahnilrlinrr nrcr/rnr/rir grin rltl S/71/7()17
Florida Building Code Online ,
Page 2 of 2
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
02/16/2012
Date Validated
02/21/2012
Date Pending FBC Approval
02/24/2012
Date Approved !
04/03/2012
Summary of Products
FL *
IMlodel, Number or Name
Description
10674.1
Owens Corning Asphalt Roofing
3-tab, laminated, starter, and hip & ridge
Shingles and Starters
Limits of Use i
Installation Instructions
Approved for: use in HVHZ: No
FL10674 R6 II er020612FINAL OC FL10674-
R6 Asphalt Shingles.pdf
Approved for use outside HVHZ: Yes
Impact Resistant:. N/A
Verified By: Robert J. M. Nieminen PE - 59166
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: Refer to ER, Section 5.
Evaluation Reports
FL10674 R6 AE er020612FINAL OC FL10674-
R6 Asphalt Shingles.pdf
Created by Independent Third Party: Yes
Back Next
Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida' is an AA/EEO employer. Copyright 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, a -mall addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not
send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions regarding DBPR's ADA web
accessibility, please contact our Web Master at webmasterOdbor.state.Fl:us.
Product Approval Accepts:
ER
azn�a.
�y�1 �rtosa"� %ecurit'go,"tbtG`S
[arY'vea<� �'vayri: Rpn
httn-//www-flnriclahnilclina_nra/nr/nr ann cltl_acnx9naram=wCTF,VXOwtl)ntRNhF,YSV%2
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT #13
ERD OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
EVALUATION REPORT
Owens Corning
One Owens Corning Parkway
Toledo, OH 436S9
Evaluation Report 037940.02.12
FL10674-R6
Date of Issuance: 02/06/2012
SCOPE:
This Evaluation Report is issued under,Rule 9N-3 and,the applicable rules and regulations governing
the use of construction materials in the State of Florida. The documentation submitted has been
reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and
Florida Building Code, Residential Volume. The products described herein have been designed to
comply with the 2010 FBC and 2010 FBC Residential Volume sections noted herein.
DESCRIPTION: Owens Corning AsphaCt`Roof Slhinglesi
LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality
Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)
changes, the referenced Quality Assurance documentation changes, or provisions of the Code that
relate to the product change. Acceptance of this Evaluation Report by the named client constitutes
agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality
Assurance documentation' changes. TrinityJERD requires a complete review of this Evaluation
Report relative to updated, Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may
be displayed in advertising literature. If any portion of the Evaluation Report Is displayed, then it
shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by
the manufacturer or its distributors and shall be available for Inspection at the job site at the
request of the Building Official.
i
This Evaluation Report consists of pages 1 through 6.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized
by RobertNiemmen, P.E. on 02/06/2012
This does not serve as an electronically signed
document Signed, sealed hardcopies have been
transmitted to [he Product Approval Administrator and
to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinityiERD does not have, nor', does it Intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates!
2. TrinitylERD Is not owned, operated or controlled by any company - manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial Interest In any company manufacturing or distributing products for which
the evaluation reports are being Issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity, involved in the approval process of the
product.
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have
demonstrated compliance with the following sections of the Florida Building Code and Florida Building
Code, Residential Volume through testing in accordance with the following Standards. Compliance is
subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
beglion Property
Standard
Year
1507.2.5, R905.2.4 Physical Properties
ASTM D3462
2007
1507.2.7.1, R905.2.6.1 Wind Resistance
ASTM D3161, Class F
2006
1507.2.7.1, R905.2.6.1 Wind Resistance
ASTM D7158, Class H
2O07
3. REFERENCES:
Entity Examination
Reference
Date
UL (CER1739) Physicals & Wind Resistance
File R2453, Vol. 3
02/15/2007
UL (TST1740) Physical Properties
06CA20263
04/18/2006
Miami -Dade (CER1592) FBC HVHZ Compliance
07-1116.12
02/14/2008
Miami -Dade (CER1592) FBC HVHZ Compliance
09-0915.12
12/16/2009
Miami -Dade (CER1592) FBC HVHZ Compliance
10-0817.09
10/27/2010
Miami -Dade (CER1592) FBC HVHZ Compliance
10-0817.10
10/27/2010
Miami -Dade (CER1592) FBC HVHZ Compliance
10-0817.08
10/27/2010
Miami -Dade (CER1592) FBC HVHZ Compliance
10-0817.07
10/27/2010
Miami -Dade (CER1592) FBC HVHZ Compliance
11-0411.03
06/16/2011
Miami -Dade (CER1592) FBC HVHZ Compliance
11-0919.05
10/13/2011
UL (QUA3743) Quality Control
Service Confirmation
Exp. 09/26/2014
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic° and Supreme® are fiberglass reinforced, 3-tab asphalt roof shingles.
4.1.2 Berkshire° are fiberglass reinforced, 4-tab asphalt roof shingles.
4.1.3 f� ration(6,) Duration® Premium, Oakridge° and
WeatherGuard® HP are fiberglass reinforced,
laminated asphalt roof shingles.
4.2 Berkshire® Hip & Ridge Shingles, High Ridge,
Hip & Ridge with Sealant and WeatherGuard° HP
Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles.
4.3 Starter Strip Plus and Starter Shingle Roll are
starter strips for asphalt roof shingles.
S. LIMITATIONS:
5.1 This Evaluation Report is not for use in the HVHZ.
5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing
Materials Directory for fire ratings of this product.
5.3 Wind Classification:
5.3.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables
1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating
the shingles are acceptable for us in all wind zones up to Vasd = 150 mph (Vint = 194 mph).
Refer to Section 6 for installation requirements to meet this wind rating.
Exterior Research and Design, LLC. Evaluation Report 037940.02.12
CertlflcateofAuthorization #9503 FL10674-R6
Date of Issuance: 02/06/2012
Page 2 of 6
f
TRINITY j ERD
5.3.2 All Owens Corning hip & ridge shingles and Starter Strip Plus noted herein are Classified in
accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating_ the
shingles are acceptable for us in all wind zones up to Vasd = 150 mph (V„n = 194 mph). Refer
to Section 6 for installation requirements to meet this wind rating.
5.3.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60
feet or less. Calculations by a qualified design professional are required for conditions outside
these limitations: Contact the shingle manufacturer for data specific to each shingle.
5.3.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.4 All products in the roof assembly shall have quality assurance audit in accordance with the
Florida Building Code and F.A.C. Rule 9N-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide
Product Approval, or. be Locally Approved per Rule 9N-3, per FBC Sections 1507.2.3, 1507.2.4
or R905.2.3.
6.2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the 'manufacturer's current published
Instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2
or R905.2, with the following exceptions:
➢ Berkshire® shingles require minimum five (5) nails per shingle.
➢ WeatherGuard® HP shingles require minimum six (6) nails per shingle.
➢ Starter Strip Plus requires minimum five (5) nails per strip.
Refer to Owens Corning publishedinformation on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less
than FBC 1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of
fastening are required. Contact the shingle manufacturer for details.
6.2.5 Minimum Nailing - Classic® & Supreme:
Hounsf Mmard a Atom pay
VW" Ams Htoh wind dssvams Y
Arw psn vlsntoi oarmshs Aroma vk fwrtss
e'Esposun
Exterior Research and Design, LLC.
Certificate ofAuthorizatlon #9503
Am pme
MaduAmn Htih MwtwdorYY
Arw pam Www" nommOss Anse visntos fwras
r p r r: t6 r �.
i SM E:posurs
Eigrosi06»
Evaluation Report 037940.02.12
FL10674-R6
Date of Issuance:02/06/2012
Page 3 of 6
6.2.6 Minimum Nailina - Berkshire@:
6"WA SWP
La th do "hdw
-ai i
I ir OW 'Sw eye
6.2.7 Minimum Nailing - Duration@ & Duration@ Premium:
4 Nall Pattem
EsWom do 4 dam
SumNIP1139unkV ana wkfth
Ar"dedawsSunNaF
tr Ir.
E.
Bqmtn
Wpuq.draspostafdn ae.os P4PU19-dd'wV$kft
6.2.8 Minimum Nallina - Oakridae(k:
4 Nall Pat.tam
Equam oat 4 d2ws
1.
- 14— Ir
6 6ff Expme
"vat EApWcOnd*6618pdg
Exterior Research and Design, LLC.
Certificate ofAuthorlzaUon #9503
'�J TRIjVI'jY (ERD
Sealarastrlp
La &a d9s:P1kcbr
0 94 ------- 0-0
" 8 8 Vf 8 Vf ew Vf47c
ship 610
6 Nag tSbflb1twIK1OU1VN1w
patlar
E
a ME opaNn
d.76XV09
Amxr tad,
LE
SWExpmm Nays SW Epoun
5ffP4f9.dOSW*On Caws 5%fVfj.&aVOOCf&
6 Nall Pam
Esquima can 6 davos
r
ir Ir
A 14
1Y
CkyNabas 6 SAr UP"
BpWd6ad@6V$pd8. I EqWddn do 6 518pdg.
Evaluation Report 037940.02.12
F1.10674-116
Date of Issuance: 02/06/2012
Page 4 of 6
6.2.9 Minimum Nailing - WeatherGuard@ HP;
u.N. aar n..
vme. i.r.i
ssl
.rll+f.rr.
6.3 Hip & Ridge Shingles:
CYD
ININIERD
6.3.1 Installation of Berkshire° Hip and Ridge Shingles, High Ridge, Hip & Ridge with Sealant and
WeatherGuardO HP Hip and Ridge Shingles shall comply with the manufacturer's current
published instructions, using four (4) nails per shingle.- Refer to Owens Corning published
information on wind resistance and installation limitations, including the use of hand -sealing for
wind warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less
than FBC 1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing - Berkshire@ Hip & Ridge and High Ridge:
6.3.4 Minimum Nailing - Hip & Ridge with Sealant:
anti Fig. 27. Hi Wind Fastening Rattem
4 Naib)
.rim Shingle
nd Discard 2" ZIPExcess 2to 1"
Sea' -~ 12 p T
' Faateninvg. 65/s" 5"Exposure
Distance
12"
Exterior Research and Design, LLC.
Certificate of Authorization #9503
Fig. 2
Toplfiew SideView
Nails Nails
Top Lerr"ed T 1
4' Piece
1' T
I
I
i
I
j:
I
JI
I
I
I
Evaluation Report 037940.02.12
FL10674-R6
Date of Issuance: 02/06/2012
Page 5 of 6
6.3.5 Minimum Nailing - WeatherGuard@ HP Hip and Ridge:
Fig. A 4 4
4— glxtbn
Pl=l gWM p
A
X7
N�I4v 4 4
A I
A
1 I
I
A I i 1
A
s'—►I
EiposUlY
7. LABELING:
FYD I
TRINITY ! ERa
Fig. C Hip & Ridge Shingle Fastening
TopVlew
Hallo Nulls
1" ��,
1` 1'
1" 1'
V uxpmrQ
I
t2'�
7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo
of the Accredited Quality Assurance Agency noted herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications
detailed in FBC Table 1507.2.7.1 / R905.2.6.1.
S. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the
installation of this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule
9N-3 QA requirements.
10. QUALITY ASSURANCE ENTITY:
Underwriters Laboratories - QUA1743; (414) 248-6409; karen.buchmann@ul.com
END OF EVALUATION REPORT' -
Exterior Research and Design, LLC.
Certifleate of Authorization #9503
Evaluation Report 037940.02.12
FL10674-R6
Date of Issuance: 02/06/2012
Page 6 of 6
FL #
FL5259-R15
Application Type
Revision
Code Version
2010
.Application Status
Pending FBC Approval
Comments
Archived
.._
Product Manufacturer POLYGLASS USA
Address/Phone/Email 150 Lyon Drive
Fernley, NV 89408
(570)384-1230 Ext242
jakins@polyglass.com
Authorized Signature James Akins
jakins@polyglass.com
Technical Representative Steve Wadding
Address/Phone/Email 150 Lyon Drive
Fernley, NV 98408
(602)363-7139
stevew@polyglass.com
Quality Assurance Representative. James Akins
Address/Phone/Email 555 Oakridge Road
Humboldt Industrial Pkwy
Hazleton, PA 18201
(800)894-4563
jakins@polyglass.com
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
1. Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who Robert Nieminen
developed the Evaluation. Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 11/30/2012
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL5259 R15 COI Trinity ERD CI - Nieminen.odf
Referenced Standard and Year (of Standard) Standard
Year
ASTM D1970
2001
ASTM D226
2006
ASTM D6164
2005
h"://www.floridabuildin%z.org/pr/Dr am) dtl.aspx?param=wGEVXOwtDgvbSgA4Zp3Crk... 5/23/2012
Florida Building Code Online,
Page 2 of 2
ASTM D6222
2002
ASTM G154
2005
ASTM G155
2005
FM 4474
2004
FRSA/TRI07320
2005
TAS 103
1995
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 04/23/2012
Date Validated 04/25/2012
Date Pending FBC Approval 04/28/2012
Summary of Products
FL #
Model, Number or
Description
Name
5259.1
Polyglass Roof
Roofing underlayments
Underlayments
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL5259 R15 II er042212FINAL POLYGLASS UNDERLAYMENTS FL5259-
R15. df
Approved for use outside
HVHZ: Yes
Verified By: Robert Nieminen PE-59166
Impact Resistant:. N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-622.5
Evaluation Reports
Other: 1.) The design pressure in.this
FL5259 R15 AE er042212FINAL POLYGLASS UNDERLAYMENTS FL5259-
1115.0f
application relates to one particular
underlayment system for use under
Created by Independent Third Party: Yes
foam -on tile systems. Refer to ER
Section 5.5.2 for other systems and
maximum design pressures. 2.) Refer
to ERSection 5 for other limits of use.
Back Next
Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Convrlaht 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, e-mail addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not
send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions regarding DBPR's ADA web
accessibility, please contact our Web Master at webmasterOdbor.state.Fl.us.
Product Approval Accepts:
FOR] OR
\ jSFC Eq
P,vsszd by vatisign
httn://www.floridabuilding.ora/nr/nr ann dtl.asnx?naram=wGEVXOwtDovbSaAaZn3Crk... 5/23/2012
01
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
PHONE: (203) 262-9245
EVALUATION REPORT FAX: (203) 262-9243
Polyglass USA, Inc. Evaluation Report 1332060.02.09-1110
150 Lyon Drive FL5259-R15
Fernley, NV 98408 Date of Issuance: 02/24/2009
Revision 10: 04/22/2012
SCOPE:
This Evaluation Report is issued under Rule 9N73 and the applicable rules and regulations governing
the use of construction materials in the State of Florida. The documentation submitted has been
reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and
Florida Building Code, Residential Volume. The products described herein have been designed to
comply with the 2010 Florida Building Code sections noted herein.
DESCRIPTION: Polyglass _hoof �Underlayments
� n $
LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality
Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)
changes, the referenced Quality Assurance documentation changes, or provisions of the Code that
relate to the product change. Acceptance of this.Evaluation Report by the named client constitutes
agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality
Assurance documentation changes. TrinityiERD requires a complete review of this Evaluation
Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may
be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it
shall be done in Its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by
the manufacturer or its distributors and shall be available for inspection at the job site at the
request of the Building Official.
This Evaluation Report consists of pages i through 10.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registiation No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized
by Robert Nleminen, P.E. on 04/22/2012
This does not serve as an electronically signed
document Signed, sealed hardcoples have been
transmitted to the Product Approval Administrator and
to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinityiERD does not have, nor does it intend to acquire or will it acquire, a financial Interest in any company manufacturing or
distributing products it evaluates.
2. TrinityiERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial Interest in any company manufacturing or distributing products for which
the evaluation reports are being Issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial Interest in any other entity Involved in the approval process of the
product.
ti
i
4
TRINITY ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have
demonstrated compliance with the following sections of the Florida Building Code through testing in
accordance with the following Standards. Compliance is subject to the Installation Requirements_ and
Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
1507.2.3, 1507.3.3, 1507.5.3,
1507.7.3, 1507.8.3, 1507.9.3
Property
Physical Properties
Standard
ASTM D226
Year
2006
1507.2.4, 1507.2.9.2, 1507.3.3,
1507.5.3
Physical Properties
ASTM D1970
2001
1507.11.2
Physical Properties
ASTM D6164
2005
1507.11.2
Physical Properties
ASTM D6222
2002
1504.6
Accelerated Weathering
ASTM G154
2005
1504.6
Accelerated Weathering
ASTM G155
2005
1504.3.1
Wind Uplift
FM 4474
2004
1507.3.3
Installation Practice
FRSA/TRI 07320
2005
1523.6.5.2.1
Physical Properties
TAS 103
1995
3. REFERENCES:
Entity
Examination
Reference
Date
FM Approvals (TST 1867)
Wind Uplift
3004091
01/12/2000
PRI (TST 5878)
Physical Properties
PRIO1111
04/08/2002
PRI (TST 5878)
Physical Properties
PUSA-005-02-01
01/31/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-01
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-02
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-03
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-018-02-01
07/14/2003
PRI (TST 5878)
Physical Properties
PUSA-028-02-01
07/13/2005
PRI (TST 5878)
Physical Properties
PUSA-033-02-01
01/12/2006
PRI (TST 5878)
Physical Properties
PUSA-035-02-01
09/29/2006
PRI (TST 5878)
Physical Properties
PUSA-055-02-02
12/10/2007
PRI (TST 5878)
Physical Properties
PUSA-061-02-02
01/28/2008
PRI (TST 5878)
Physical Properties
PUSA-076-02-01
02/22/2008
PRI (TST 5878)
Physical Properties
PUSA-083-02-01
04/14/2008
PRI (TST 5878)
Physical Properties
PUSA-088-02-01
07/29/2009
MTI (TST 2508)
Physical Properties
JX20H7A
04/01/2608
MTI (TST 2508)
Physical Properties
RX14E8A
01/29/2009
ERD (TST 6049)
Physical Properties
11752.09.99-1
02/08/2000
ERD (TST 6049)
Wind Uplift
11776.06.02
01/16/2003
ERD (TST 6049)
Physical Properties
02200.07.03
07/14/2003
ERD (TST 6049)
Wind Uplift
P1740.01.07
01/04/2007
ERD (TST 6049)
Physical Properties
P5110.04.07-1
04/11/2007
ERD (TST 6049)
Wind Uplift
P9260.03.08
03/21/2008
ERD (TST 6049)
Physical Properties
P13450.08.09
08/13/2009
ERD (TST 6049)
Wind Uplift
P30540.11.09-R1
11/30/2009
ERD (TST 6049)
Physical Properties
P33360.06.10
06/25/2010
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R10
Certificate ofAuthorizatlon #9503 FL5259-R15
Revision 10: 04/22/2012
. Page 2 of 10
2
4.
5.
QOTRINITYIERD
Entity Examination Reference Date
ERD (TST 6049) Physical Properties P33370.03.11 03/02/2011
ERD (TST 6049) Physical Properties P33370.04.11 - 04/26/2011
ICC-ES (EVL 2396) IBC Compliance ESR-1697 11/01/2011
Miami -Dade (CER 1592) HVHZ Compliance NOA Current
Polyglass USA Manufacturing Affidavit Products Current 02/18/2009
Polyglass USA P/L Affidavit Mule -Hide Cross Ltg 03/01/2008
Polyglass USA Materials Affidavit Polystick SA Compound 08/18/2011
UL, LLC. (QUA9625) Quality Control File No. R14571, Vol 1 Exp. 11/30/2012
PRODUCT DESCRIPTION:
4.1 Mechanically Fastened Underlavments•
4.1.1 ELASTOBASE is a fiberglass reinforced, SIBS modified bitumen base sheet.
4.1.2 ELAsroBASE P is a polyester -reinforced, SBS modified bitumen base sheet.
4.2 Self -Adhering Underlavments•
4.2.1 POLYSTICK MTS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber
reinforced, surfaced with polyolefinic film surface; meets ASTM D1970 and TAS 103.
4.2 2 PoLYSTICK IR-Xe is a nominal -al -mil thick rubberized asphalt waterproofing membrane, glass
`�fibe lerr nforced, vhfi-an'aggreg-ate surface; meets ASTM D1970.
4.2.3 POLYSTICK TU is a nominal 100-mil thick rubberized asphalt waterproofing membrane, glass fiber
reinforced, with a granular surface; meets ASTM D1970 and TAS 103.
4.2.4 POLYSTICK TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane, glass
fiber reinforced, with a polyester fabric surface; meets ASTM D1970 and TAS 103.
4.2.5 POLYSTICK TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-
fiber/polyester reinforced, with a granular surface; meets ASTM D1970 and TAS 103.
4.2.6 POLYFLEX SAP, POLYFLEX SAP FR, MULE -HIDE SA-APP CAP SHEET AND MULE -HIDE SA-APP CAP SHEET (FR)
are a polyester reinforced, APP modified bitumen cap sheets.
4.2.7 DUAL PROTm is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane,
fiberglass reinforced, with a polyester fabric surface.
4.2.8 TILE PROTM is .a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane,
fiberglass reinforced, with a polyester fabric surface.
4.3 Mechanically Fastened and/or Bonded Underlavments
4.3.1 ELAsToFLEx S6G AND ELASTOFLEX S6G FR are polyester reinforced, SBS modified bitumen cap
sheets.
4.3.2 POLYFLEx G AND PoLYFLEx.G FR are polyester reinforced, APP modified bitumen cap sheets.
LIMITATIONS:
5.1 This Evaluation Report is not for use in the HVHZ.
5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing
Materials Directory for fire ratings of this product.
5.3 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is
specifically referenced within FBC approval documents. If not listed, a request may be made
to the AH] for approval based on this evaluation combined with supporting data for the
prepared roof covering.
Exterior Research and Design, LLC.
Certificate ofAuthorizadon #9503
Evaluation Report P12060.02.09-R10
FL5259-R15
Revision 10. 04/22/2012
Page 3 of 10
�,.J � RIMT'ZIiERD
5.4• Allowable roof covers a lied ato the "pried- ment f II
s are as
Table 1: Root Cover Options
Underlayment
Asphalt
Shingles
Nall -On Tile
Foam -On
Tile
Metal
Wood
Shakes &
Slate
Shingles
Elastobase
Yes
Yes
No
Yes
Yes
Yes
Elastobase P
Yes
Yes
No
Yes
Yes
Yes
Polystick MTS
Yes
Yes
No
Yes
Yes
Yes
Polystick IR-Xe
Yes
No
No
No
Yes
Yes
Polystick TU
Yes
Yes
Yes
No
Yes
Yes
See 5.4.1
Polystick TU P
Yes
Yes
Yes
No
Yes
Yes
See 5.4.1
Polystick TU Plus
Yes
Yes
Yes
Yes
Yes
Yes
See 5.4.1
Dual Pro
Yes
Yes
No
Yes
Yes
Yes
Tile Pro
Yes
Yes
Yes
Yes
Yes
Yes
See 5.4.1
Elastoflex S6G or S6G FR
Yes
Yes
No
No
Yes
Yes
Polyflex G or G FR
Yes
Yes
Ye
No
Yes
Yes
See 554. i
Polyflex SAP or SAP FR
Yes
Yes
Yes
No
Yes
Yes
See 5.4.1
Mule -Hide SA-APP Cap Sheet
Yes
or SA-APP Cap Sheet (FR)
Yes
Yes
See 5.4.1
No
Yes
Yes
5.4.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives unless tensile
adhesion / long term aging data from an accredited testing laboratory is provided.
➢ Polyfoam PolyPro AH160: Polystick TU, Polystick TU P, Polystick TU Plus, Polyflex G,
Polyflex G FR, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -
Hide SA-APP Cap Sheet (FR) or Tile Pro.
➢ Dow TileBond: Polystick TU P, Polystick TU Plus, Polyflex SAP or Tile Pro
5.4.2 For nail -on file systems over Polystick MTS, battens are required for loading / staging of the
tile.
5.4.3 A 2-ply underiayment system, consisting of Polystick MTS followed by Polystick MTS, TU, TU P
or TU Plus, or Polyflex SAP is allowable for use under mechanically attached prepared roof
systems. This is not a requirement, but is allowable if a 2-ply underiayment system is
desired.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1110
CertiflCate ofAuthorizatlon #9503 FL5259-R15
Revision 10: 04/22/2012
Page 4 of 10
TRINITY J ERD
5.5 Allowable substrates are noted below:
5.5.1 Direct -Bond to Deck:
Polystick, Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP
Cap Sheet (FR) self -adhered to:
➢ New untreated plywood;
➢ ASTM D41 primed new untreated plywood;
➢ Existing plywood;
➢ ASTM D41 primed existing plywood;
➢ ASTM D41 primed OSB;
➢ Southern Yellow Pine;
➢ ASTM D41 primed Southern Yellow Pine;
➢ ASTM D41 primed. structural concrete;
➢ Huber Engineered Woods "ZIP System" Panels (designed and installed to meet wind loads
for project).
Note: Polyg/ass does not require priming of new or existing plywood sheathing. New or
existing plywood sheathing should be cleaned of all dirt and debris prior to application of
Polystick membranes.
Elastoflex S6G or S6G FR in hot asphalt to:
➢ ASTM D41 primed structural concrete.
Polyflex G or G FR torch -applied to:
➢ ASTM D41 primed structural concrete.
5.5.2 Wind Resistance for Underlayment Systems in Foam On Tile Aoolications: FRSA/TRI 07320
does not address wind uplift resistance of all underlayment systems beneath foam -on tile
systems, where the underlayment forms part of the load -path. The following wind uplift
limitations apply to underlayment systems that are not addressed in FRSA/TRI 07320 and are
used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind
load resistance based on allowable wind loads. Refer to FBC 1609.1.5 for determination of
design wind pressures.
5.5.2.1 Maximum Design Pressure — -622 5 psf.
Deck: Structural concrete to meet project.requirements to satisfaction of AHJ.
Primer: ASTM D41
Underlayment: Polyflex G or G FR torch -applied.
5.5.2.2 Maximum Design Pressure = -315 psf.
Deck: Structural concrete to meet project requirements to satisfaction of AHJ.
Primer: ASTM D41
Underlayment: Polystick TU, Polystick TU P, Polystick TU Plus, Tile Pro, Polyflex SAP, PolyFlex
SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR).
5.5.2.3 Maximum Design Pressure = -135 psf.
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optional) ASTM D41
Joints: Min. 4-inch wide strips of Elastoflex SA-V over all plywood joints.
Underlayment: Polystick TU, Polystick TU P, Polystick TU Plus, Polyflex SAP, PolyFlex SAP FR,
Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR)
Exterior Research and Design, I.I.C. Evaluation Report P12060.02.09-R10
Certificate of Authorisation #9503 FL5259-R15
Revision 10: 04/22/2012
Page 5 of 10
�.l TRINITY IERD
5.5.2.4 Maximum Design Pressure = -90 per.
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AH].
Primer: (Optional) ASTM D41
Underlayment: Polystick TU, Polystick TU P, Polystick TU Plus, Polyflex SAP, PolyFlex SAP FR,
Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR)
5.5.2.5 All other direct -deck, adhered Polyglass underlayment systems beneath foam -on tile systems
carry a Maximum Design Pressure of -45 psf.
5.5.3 Bond -to -Insulation:
➢ Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR)
self -adhered to: ASTM C1289, Type II, Class 1 polyisocyanurate or Type V
polyisocyanurate-composite insulation; DensDeck DuraGuard; DensDeck Prime; or
SECUROCK Gypsum -Fiber Roof Board.
➢ Elastoflex S6G or S6G FR in hot asphalt to: DensDeck Prime or SECUROCK Gypsum -Fiber
Roof Board.
➢ Polyflex G or G FR torch -applied to: ASTM D41 primed structural concrete; DensDeck
Prime or SECUROCK Gypsum -Fiber Roof Board.
For Installation under mechanically attached prepared roof coverings, Insulation shall be
attached per minimum requirements of the prepared roof covering manufacturer's Product
Approval. For installations under foam -on tile systems, insulation attachment shall be
designed by a qualified design professional and installed based on testing of the
insulation/underlayment system In accordance with FM 4470, Appendix K or TAS 114,
Appendix J.
5.5.4 Bond to Mechanically Attached Base Laver:
➢ Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR)
Dual Pro or Tile Pro self -adhered to: ASTM D226, Type I or II felt; Elastobase; Elastobase
P or Mule -Hide Nail Base.
➢ Elastoflex S6G or S6G FR in hot asphalt to: ASTM D226, Type I or II felt; Elastobase;
Elastobase P or Mule -Hide Nail Base.
➢ Polyflex G or G FR. torch -applied to: Elastobase; Elastobase P or Mule -Hide Nail Base.
For installations under mechanically attached prepared roof coverings, base layer shall be
attached per minimum codified requirements. For installations under foam -on the systems,
base layer shall be attached per minimum requirements of FRSA/TRI 07320/8-05 or RAS 120.
5.6 Exposure Limitations:
5.6.1 Elastobase, Elastobase P, shall not be left exposed for longer than 30-days after installation.
5.6.2 Polystick IR-Xe, Dual Pro or Tile Pro shall not be left exposed for longer than 90-days after
installation.
5.6.3 Polystick MTS, TU, TU P or TU Plus shall not be left exposed for longer than 180-days after
installation.
5.6.4 Polyflex SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not
have an exposure limitation, unless the prepared roof covering is to be adhesive -set tile, in
which case the maximum exposure is 30 days.
5.6.5 Elastoflex S6G or S6G FR or Polyflex G or G FR does not have an exposure limitation, unless
the prepared roof covering is to be adhesive -set tile (Polyflex G or G FR only), in which case
the maximum exposure is 180 days.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R10
Certificate of Authorisation #9503 FL5259-R15
Revision 10: 04/22/2012
Page 6 of 10
'J TRINITYIERD
5.7 For tile roof installations governed by the FRSA/TRI 07320/8-05 Installation Manual, Fourth
Edition, use is limited to the following. Reference is made to the FRSA/TRI Technical Brief
titled "Florida High Wind Roof Tile Self -Adhered Underlayment Requirements as of
02/14/2011" for limitations for self -adhering underlayments used beneath tile roof systems.
Table 2: Tile System Options per FRSA/TRI 07320/8-05
System
Underlay
Option
Section
Reference
Product(s)
3.02A
1
Batten
Modified Cap Sheet
Elastoflex S6G or Elastoflex S6G FR; Polyflex G or G FR
only
System One:
2
3.02B
No. 30 / Modified Cap
Base Layer: Elastobase; Elastobase P
Sheet
Top Layer: Elastoflex S6G or Elastoflex S6G FR; Polyflex G
Mechanically
or G FR
Fastened Tile,
4
3.02D
No. 30
Elastobase; Elastobase P
Unsealed or
5
Self -Adhered
Polystick MTS; TU; TU P; TU Plus; Polyflex SAP or SAP FR;
Sealed
Underlayment
3.02E
Underlayment
Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR);
System
Dual Pro; Tile Pro
Base Layer: ASTM D226, Type II; Elastobase; Elastobase P;
6
3.02E
No. 30 / Self -Adhered
Mule -Hide Nail Base
Underlayment
Top Layer: Polystick MTS; TU; TU P; TU Plus; Polyflex SAP
or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap
Sheet (FR); Dual Pro; Tile Pro
3.02A
1
Batten
Modified Cap Sheet
Elastoflex S6G or Elastoflex $6G FR; Polyflex G or G FR
only
System Two:
2
3.02B
No. 30 / Modified Cap
Base Layer: Elastobase; Elastobase P
Sheet
Top Layer: Elastoflex S6G or Elastoflex S6G FR; Polyflex G
Mechanically
or G FR
Fastened Tile,
Sealed
Self -Adhered
Polystick TU; TU P; TU Plus; Polyflex SAP or SAP FR; Mule-
Underlayment
4
3.02D
Underlayment
Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR); Dual
System
Pro; Tile Pro
Base Layer: ASTM D226, Type II; Elastobase; Elastobase P;
5
3.02E
No. 30 / Self -Adhered
Mule -Hide Nail Base
Underlayment
Top Layer: Poiystic4 TU; TU P; TU Plus; Polyflex SAP or SAP
Fit, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR)
Dual Pro; Tile Pro
i
3.02A
Modified Cap Sheet
Polyflex G or G FR
2
3.02B
No. 30 /'Modified Cap
Base Layer: Elastobase; Elastobase P
System Four
'A":
Sheet
Top Layer: Polyflex G or G FR
4
3.0213
Self -Adhered
Polystick TU; TU P; TU Plus; Polyflex SAP or SAP FR; Tile
Adhesive -Set
Tile, Unsealed or
Underlayment
Pro; Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR)
Sealed
Base Layer: ASTM D226, Type II; Elastobase; Elastobase P;
Underlayment
System
5
3.02E
No. 30 / Self -Adhered
Mule -Hide Nail Base
Underlayment
Top Layer: Polystick TU; TU P; TU Plus; Polyflex SAP or SAP
FR; Tile Pro; Mule -Hide SA-APP Cap Sheet or SA-APP Cap
Sheet(FR)
1
3.02A
No. 30 / Modified Cap
Base Layer: ASTM D226, Type II; Elastobase; Elastobase P
System Four
Sheet
Top Layer: Polyflex G or G FR
3
3.02C
Self -Adhered
Polystick TU; TU P; TU Plus; Polyflex SAP or SAP FR; Tile
'B":
Adhesive -Set
Underlayment
Pro; Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR)
Base Layer: ASTM D226, Type II; Elastobase; Elastobase P;
Tile, Sealed
Underlayment
4
No. 30 / Self -Adhered
Mule -Hide Nail Base
System
3.021)
Underlayment
Top Layer: Polystick TU; TU P; TU Plus; Polyflex SAP or SAP
FR; Tile Pro; Mule -Hide SA-APP Cap Sheet or SA-APP Cap
Sheet(FR)
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1110
Cerdi7cate ofAuthorizadon #9503 FL5259-R15
Revision 10: 04/22/2012
Page 7 of 10
a
TRINITY 1 ERD
6. INSTALLATION:
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published
Installation requirements subject to the Limitations set forth in' Section 5 herein and the
specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the
substrate thoroughly to remove any dust and debris prior to application, and prime the
substrate (if applicable).
6.3 Elastobase Elastobase P or Mule -Hide Nail Base:
6.3.1 Shall be installed in compliance with the codified requirements for ASTM D226, Type II
underiayment in FBC Sections 1507 for the type of prepared roof covering to be installed.
6.3.2 For use in non -tile applications:
6.3.2.1 Reference is made to the current edition of the NRCA Steep -slope Roofing Manual and ARMA
recommendations for installing shingle underlayments and flashings
6.3.2.2 Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of 'Polystick,
Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), Dual Pro or
Tile Pro, self -adhered, Elastoflex S6G or S6G FR in hot asphalt or Polyflex G or G FR, torch
applied.
6.3.3 For use in tile applications, reference is made to Polyglass published installation instructions in
conjunction with FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2
herein.
6.4 Polystick MTS IR-Xe TU TU P or TU Plus Polyflex SAP or SAP FR Mule Hide SA
APP Cap Sheet or SA-APP Can Sheet (FR) Dual Pro or Tile Pro:
6.4.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment
in FBC Sections 1507 for the type of prepared roof covering to be installed.
6.4.2 For non -tile applications:
6.4.2.1 All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR
and Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) should be back -nailed in selvage
edge seam in accordance with Polyglass/ Mule -Hide Back Nailing Guide. Nails shall be
corrosion resistant, it gauge ring -shank type with a minimum 1-inch diameter metal disk or
Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back -
nailed using the above noted fasteners and spacing, in area marked "nail area, area para
clavar" on the face of membrane. The head lap membrane is to cover the area being back -
nailed
6.4.2.2 All seal -lap seams (selvage laps) must be firmly rolled with a minimum 28 lb. hand roller to
ensure full contact and adhesion. For Dual Pro and Tile Pro, align the edge of the top sheet to
the end of the glue pattern (the sheet will overlap the fabric).
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1110
Certificate of Authorization #9503 FL5259-R15
Revision 10: 04/22/2012
Page 8 of 10
�TRIN(jYIERD
View of Ovelap Seam of Dual Pro and Tile Pro
6.4.2.3 All over -fabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyglass
Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing
Cement, Polyglass PG500 MB Flashing Cement, Polystick TU Plus Tile Underlayment Flashing
Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry
Electrometric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade
mastic, applied in between the application of the lap.
6.4.2.4 Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as
crickets, exposed valleys, or exposed roof to wall details
6.4.2.5 Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55
Premium Modified Flashing Cement, -Polyglass Polyplus 50 Premium MB Flashing Cement,
Polyglass PG500 MB Flashing Cement, Polystick TU Plus Tile Underlayment Flashing Cement,
Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide' 251 Premium Wet/Dry
Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade
mastic to the area in need of repair, followed by a minimum 6 x 6 inch patch of the Polystick
material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed,
shall be installed in a water shedding manner.
6.4.2.6 All Polystick membranes shall be installed to ensure full contact with approved substrates.
Polyglass requires a minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff
broom with approximately 40-lbs of load applied for the field membrane. Hand rollers are
acceptable for rolling of patches, laps (min. 28 lb roller) or small areas of the roof that are not
accessible to a large roller or broom.
6.4.3 For tile applications (not allowed for Polystick IR-Xe):
6.4.3.1 -Reference is made to Section 6.4.2 herein in conjunction with FRSA/TRI 07320/8-05
Installation Manual, Fourth Edition, and Table 2 herein, using the instructions noted above as
a guideline.
6.4.3.2 For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the
tile.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1110
Certificate ofAuthorization #9503 FL5259-1115
Revision 10: 04/22/2012
Page 9 of 10
`J TRINITY (ERD
6.5 Elastoflex S6G or 16G FR:
6.5.1 Elastoflex S6G or S6G _FR shall be installed in compliance with current Polyglass published
installation requirements. For use in nail -on tile applications, reference is made to FRSA/TRI
07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein.
6.5.2 Elastoflex S6G or S6G FR shall be fully asphalt -applied to the substrates noted in Section 5.5.
Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, and off set end -laps
minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete
mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge.
6.6 Polyflex G or G FR:
6.6.1 Polyflex G or G FR shall be installed in compliance with current Polyglass published installation
requirements. For use in tile applications, reference is made FRSA/TRI 07320/8-05
Installation Manual, Fourth Edition, and Table 2 herein.
6.6.2 Polyflex G or G FR shall be fully asphalt -applied to the substrates noted in Section 5.5. Side
laps shall be minimum 3-inch . and end -laps minimum 6-inch wide, and off set end -laps
minimum 3 feet from course to course. Side and end laps shall be fully heat -welded and
inspected to ensure minimum 3/8-Inch flow of modified compound beyond the lap edge.
6.7 Tile Staging:
6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment. Refer to Polyglass published requirements for tile staging..
6.7.2 Battens and/or Counter -battens, as required by the the manufacturer and FRSA/TRI 07320/8-
05 must be used on' all roof slopes greater than 7:12. For roof slopes in excess of 61/4:12,
precautions should be taken, such as the use of battens, to prevent tile sliding during the
loading process.
6.7.3 For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the
tile.
6.7.4 The minimum cure time after installation of self -adhering membranes and before loading of
roofing tiles is forty-eight (48) hours.
7. LABELING:
Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the
Accredited Quality Assurance Agency noted herein.
S. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the
installation of this product.
9: MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C. Rule 9N-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL, LLC — QUA9625; (314) 578-3406; k.chancellor@us.ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R10
Certificate of Authorization #9503 FL5259-RIS
Revision 10: 04/22/2012
Page 10 of 10