Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSDATE: FEES DUE: RECEIPT #: I Permit #: / A 4- Planning & Development Services Department SC c p Building & Code Regulation Division By o 2300 Virginia Avenue S't Ft. Pierce, FL 34982-5652 LUCie �s. s_ Tel.772-462-1553 c��n� APPLICATION FOR ROOF PERMIT SEE REVERSE SDE FOR INSTRUCTIONS 1. Location/Site Address: 8307 Fort Walton Ave, Fort Pierce, FL 34951 2. Parcel ID Number: 1 301-606-0027-000-2 Office Use Only Section I Township Range, Ma Pa a ZonmLF I Land Use nk 3. Description of Project or Work Activity: 4. Total Roof Area (square feet): Z 3 C-�2 5. Roof Pitch: �/J Zr 6. Type of Roof: [ X] Fiberglass Shingle [ ] Concrete Roof Tile [ ] ood Shake / Shingle [ ] Tar & Gravel [ ] Modified Bitumen [ ] Other [ X] Product Approval required for all types of Roofing Material (2 Sets) [ ] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product Approval attached ** Roof Mitigation per F.S. 553.844 will be required. 7. Owner Information J �p 8. Contractor Information Name: L' d- FL Reg/Cert #: (-C� 1 ti 1 R R Address: 8307 Fort Walton Ave County Cert#:�,� City: Fort Pierce State: `/ FL 1 / Zip: 3 4 9 51 Phone: )� q 9. Value of Construction: $ $ 4 , 9 9 7.9 3 Business Name: Atlantic Roofing II Cell Phone: 772-492-8493 "Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval. CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all of te information conta' this ap icadon is correct and that all work will be done in comp ' 1 a;plicabI s re 11atconstruction and zoning. William Lasky, Jr. PRINT QUALIFIERS/OWNERS NAME SIGNATURE OF QUALIFI OWNS STATE OFFLORIDA,COUNTY .,F.��ZIndian River ACKNOWLEDGEDBEFOR�1'T�.'�_Z9 DAYOF May 20 12,BY William Lasky., Jr. WHO Is ME OR HAS / / Steven N Cottrell SIGNATM (,Tir' NOTARY- j Q TYPE OR PRINT NAME OF NOTARY COMMISSION NUMBER F / / tJ 6C5 S VEN N COTMELL COMMISSION # EE198W5 EXPIRES May 15, 2016 NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Revised 4/26/2010 v l C �i ,off 31b0 I Je A Ma310'HllgS QglOPvl 3H.L JO Ad00 1038wo ON 31ib1 V SI S*U IVHI "UN30 Ol SI SIHI UN100 310nl .LS volums SO 31ris 9lob'91 Am 83lNdl(3 poonpoiduolleoHlluapl;oadA1 S9988IMMOI991 Zl:.Io.oll&.Iq:,,d;;4:�nleust) d'uud) '1'13MU03NOMS uolle3l;l3uapl pampoid Jo -;�umowl ApeuosJad paln3axa sem luawtuisul woym;o;legaq uo /Wed (aalsnn'ua:)Lp s•a) A11Joglne;o adA.L ;o aweN anuaAV u0}isM -4ao3 Lou Jo; Q aauMO se 3 Ag Z 1-0Z ';oAep --fTslyl aw aJo;aq paspalmou:l3e seM 1ua J1sul sulosaJo; 041 (aow0/allu sNoleusl5) ' .ZaUMO JaseueW/jau:ld7�P-9111'1/Ja3S}0 p • oy1nV s,aassal Jo s�aump Jo'aassal Jo Jaump;o aJnleusl5) •;allaq pue aspalmou:I Aw 104saq 841 Ol awl aJe ulaJayl palels sloe; ayi;eyl pue lnawa3UaW wa3;D aollou PulosaJo; agl peal aney I leyl aJel3ap I'/Nn(Jad;o Aiieuad Japun '1N3 W 3DN3W W OO d0 3DIlON uno k 9NIOHOD3H HO HHOM 9NIDN31NWOO 3HOi39 A3 NH01 LV NV HO H30 N31 HnOA Him 1lnSNO0'9NIDNVNIi NIV190 Ol ONIM nOA it 'NOIJ33dSNi 1SHIi 3H13HOA39 3lis 90f 3Hl N0031SOd ONV 03OH003H 3a 1snw 1N3W33N3 W WOO 10 33IJ0N V'ALH3dOHd mak 01 S.LN3W3AOHdWI HOi 33IML 9NIAVd Hn0A NI 1lnS311 NVD ONV'S3J.n1VJS VOIHOIi'£I'£IL NOLL73S'I1HVd'£IL H3ldVHD H3ONn S1N3WAVd 113dOHdWI 03u301SNOD 3HV1N3WIMMOD i0 3DLLON 3H1 10 NOI.LWldX3 3H1H31iV H3NMO 31-L A9 3OVW S1N3WAVd ANV:H3NMO 019NINHVM (pa01oods sl alep luaia;pp a ssalun 9ulpioowjo alep ayl woJ; JeaA I aq ll! m 1nq'Jopejluo3 ag1 olluawAed Ieug pue uoll3nilsuo3;o ualieldwo3 ay1 aJo;aq aq )Au Aew alep uolleJldxa ag1) :lUawa3Uaww03;0 a3llou;O alep uolleJldx3 :Jaumo Aq paleuslsep Algua Jo uosiad 10 Jagwnu auoyd •saln1e15 epPoli'(q) (i)£T EIZ uoI133S ul papinoid se 031ioN s iouan agl;o Ado a anlanj of ;o saleuslsap Jaump';lasiay Jo;Iaswlg of uolllppe ul :ssaJppV :JagwnN auoyd :aweN salnleiS eppoli''L(e) (I)€I'€IZ uoll3aS M Papinoid se panics aq Aew s3uawn3op Ja410 Jo s83llou wogm uodn Jaumo Aq poleuslsop eplJoli;o 03e1S 041 ulgi!m suosJad :ssaJppe sjapual :JagwnN auoyd :aweN Japual :Jagwnu auoyd auON :ssaJppe pue aweN S :puoq;o lunowV :(pay3eue sl puoq ivawAed 84110 Adm e'algnlldde;l) AiainS E 6 V —76 — LL :JagwnNauoyd r!3 3LIORDEL 0.19A 'aAV LDJEV OZOV:SSOJPPVJOPeJIUQ:) -DUI [goEag 0.19A 30 II uT3oog oF:IuEi4V :aweNsJoPeJluoO :(anoge palsll Jaump woJ;luaJaHlp JI) Japlogallll aldwls aa;;o ssaJppe pue aweN :A1Jadoid ul lsaialul ssaJppV Aa8Mo7 g 2ST'I Aa=;;ar Z waTT ITM aweN :luauianoidwl 841 Jo; p0139J1u03 aassal ag1A uollewJo;ul vassal Jo uollewJo;ul Jaumo Joog aZ uTgS aoej ag 11 aAowag :luawanoidwl;ouolidlnsopleJauag 5L32g pooMaxEZ JanuaAV UOgTPM ga03 LO£9'(algellene;lssaippelaoilspue):AZJadOidlouolldlosealesal •luawa3uawwoD 10 031ION s(yl ul papinad sl uollewJo;ul 9ulmollo; ayl 'sainimS eplJoli'£IL JaidegD 411m a3uepl = ul pue'A1Jadoid leaf upiao of apew aq Illm ivawamudwl Imp aollou sank AgaJaypouslsiapun agl Z-00 - Z - - 'oNOI1OAXel 1N3W3:)N3WW0:) d0 DUON apnl•1S;oA4unoD eppoli;oalelS 'ON 1pwad AId 9Z:Z, ZT0Z/L0/90 PePaOOag 'LZ6Z asvd L61. DOH UO LOTZTLE # HIIa ALLNnOO SIOM INNS - IMOO IMOU10 3HS av A=0 'HSIYIS '3 Hd3SOP Property Appraiser - St.Lucie '- inty, FL Page 1 of 1 PROPERTY RECORD CARD William L Jeffrey Record: 1 of 1 «Prev Next» Spec.Assmnt Taxes Exemptions Permits Home Print Property Identification CIE Site Address: 8307 Fort Walton Av Sec/Town/Range: 02 :34S :39E ParcellD: 1301-606-0027-000-2 Account*: 1437 v� 4 Map ID: Land Use: SF Res RS-4 Zoning: RS-4 CitylCnty: St Lucie County Ownership and Mailing Legal Description Owner: William L Jeffrey Lisa R Lowery LAKEWOOD PARK -UNIT 6- BLK 57 LOT27 (MAP 13/02S) (OR 555- Address: 8307 Fort Walton Ave 382) Fort Pierce FL 34951-1397 Sales Information Assessment 2011 Final Total Land and Building Date Price Code Deed Book/Page 2011 Final: 39100 Land Value: 4800 Acres: 0.23 8/1/1987 52500 00 CV 0555 / 0382 Assessed: 39100 Building Value: 34300 12/1/1986 0 01 CV 0547 / 2079 Ag.Credit: 0 Finished Area: 1088 SgFt 12/1/1986 4000 00 CV 0526 / 1327 Exempt: 25000 Taxable: 14100 Taxes: 286.9 BUILDING INFORMATION �1 Exterior Features View: - RoofCover: FS - Fibrglss Shg RoofStruct: HP - Hip ExtType: HD+ - HD+ YearBit: 1987 Frame: - Grade: D+ - D+ EffYrBlt: 1987 PrimeWall: WS - Wood/Sheath StoryHght: 0010 -1 Story No.Units: 1 SecWall: - Interior Features BedRooms: 2 Electric: MX - MAXIMUM PrmintWall: DW - Drywall FullBath: 2 HeatType: FHA - FrcdHotAir AvgHt/FI: STD 1/213ath: 0 HeatFuel: ELEC - Electric Prm.Flors: CU - Carpet %A/C: 100 %Heated: 100 %Sprinkled: 0 Special Features and Yard Items Land Information Type Y!S Qty. Units Qual. Cond. YrBlt. No. Land Use Type Measure Depth 1 0100-SF Res BI-Front Ft 75 131 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED. http://www.paslc.org/paslc/Prc.asp?prclid=l30160600270002 6/8/2012 Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 772-462-2165 or 772-462-2172 Fax: 772-462-6443 ROOF INSPECTION AFFIDAVIT Re: Permit #- I, William Lasky, _Jr. _ . licensed as a(n)Contractor*/Fngineer/Architect (Please print name & circle license type) *FS468 Building Inspector *General, Building, Residential or Rooflng Contractor or any individuuf ce0ad under 468 F.S. to make Such an Inspection. On or about Ug • I •r7 D 126 ,1 did personally inspect the roof deck nailing (Date) work at: 8307 Fort Walton Ave. (Job site address) Based upon that examination l have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 554.1844 F.S.) r signature and Seal STATE OF FLORIDA COUNTYOF IL1c32an River CCC1326188 License # Sworn to and subscribed before me this day of �x.> 20J byWiiliam Lasky, Jr •.. Who is personally kn wn to me�atpxtpol xxxxxxxxxxxxXXXXXxxx=td s Notary Public, State of Florida 81MU N COTMELL MY COUMNION 6 691'1IMS Signature of Notary: $�� ts1Q4e Commission Number. 6,45�- (Se En 02/19/2012 9��Yf ATLANTIC ROOFING II OF VERO BEACH, INC. Lit. # CCC1326188 Ph:772-492-8493 Fax:772-257-5740 Tuesday, May 29, 2012 TO: Lisa Lowery 8307 Fort Walton Avenue Fort Pierce, FL 34951 RE: Re -Roof Residence 4020 43`d Ave Vero Beach, FI 32960 E-Mail: wliatrCeDaol.com_ We propose the following furnished and installed: ** Remove existing roofing, haul all related debris from job site ** Nail off plywood to code ** Install PolyGlass PolyStick IR-X vapor barrier ** Install 130 MPH Dimesional Shingles (color to be determined by customer) using ring shank roofing nails. ** White galvalume flashing and new lead plumbing jacks. ** Dade County approved Suntek Skylite ** Lemanco Shingle over ridge vent ** Included in price is permit and inspections TOTAL MATERIAL AND LABOR $ 4,997.93 ** 50% DEPOSIT 50% UPON COMPLETION ** All material is guaranteed to be as specified. All work to be completed in a workmanlike manner according to standard practices. Any alteration or deviation from above specifications involving extra cost will be executed only upon written orders, and will become an extra charge over and above. Owner is to carry fire, tornado and other necessary insurance. Our workers are fully covered by Workers Compensation Insurance. With the consent of the Bu er an rotten lumber or unsuitable substrate materials which are disclosed as the work grogresses and which are not specifically mentioned in this Proposal and agreement will be replaced or made suitable and any additional costs (Cost Plus 1091o) will be added to the contract. Authorized FROM ISSUANCE 05/29/2012 ACCEPTANCE of PROPOSAL The above specifications, prices and conditions are satisfactory and hereby accepted. You are authorized to do the work as specified. Accepted by: Date of Acceptance:N2 Florida Building Code Onlin ' Page 1 of 2 /' b' (�I a Depa "flent BCIS Home' Log In User Registration Hot Topics Submit Surcharge is Stats & Facts E Publications € FBC Staff j; BCIS Site Map !i Links Search Busines P Ofiess� Product Approval �}ppC ;USER: Public User gulation rii!!��±i}iI!nrr:�l Product Approval Menu > Product or Aoolication Search > Aoolication List > Applfcation Detail � FL # FL10674-R6 a Application Type Revision Code Version 2010 Application Status Approved Comments 0Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkw Toledo, OH 43659 (740)404-7829 greg.keeler@owenscorning. 99 Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo, OH 43659 mel.sancrant@owenscornig.com mel.sancrant@owenscornig.com Quality Assurance Representative Address/Phone/Email v Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Robert J.M. Nieminen PE-59166 Underwriters Laboratories Inc. 09/26/2014 John W. Knezevich, PE Z' Validation Checklist - Hardcopy Received FL10674 R6 COI Trinity ERD CI - Nieminen.odf Standard ASTM D3161, Class F ASTM D3462 ASTM D7158, Class H Year 2006 2007 2007 1�11rx•//xxrxxnxr flnrirlahnilrlinrr nrcr/rnr/rir grin rltl S/71/7()17 Florida Building Code Online , Page 2 of 2 Sections from the Code Product Approval Method Method 1 Option D Date Submitted 02/16/2012 Date Validated 02/21/2012 Date Pending FBC Approval 02/24/2012 Date Approved ! 04/03/2012 Summary of Products FL * IMlodel, Number or Name Description 10674.1 Owens Corning Asphalt Roofing 3-tab, laminated, starter, and hip & ridge Shingles and Starters Limits of Use i Installation Instructions Approved for: use in HVHZ: No FL10674 R6 II er020612FINAL OC FL10674- R6 Asphalt Shingles.pdf Approved for use outside HVHZ: Yes Impact Resistant:. N/A Verified By: Robert J. M. Nieminen PE - 59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to ER, Section 5. Evaluation Reports FL10674 R6 AE er020612FINAL OC FL10674- R6 Asphalt Shingles.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida' is an AA/EEO employer. Copyright 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, a -mall addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions regarding DBPR's ADA web accessibility, please contact our Web Master at webmasterOdbor.state.Fl:us. Product Approval Accepts: ER azn�a. �y�1 �rtosa"� %ecurit'go,"tbtG`S [arY'vea<� �'vayri: Rpn httn-//www-flnriclahnilclina_nra/nr/nr ann cltl_acnx9naram=wCTF,VXOwtl)ntRNhF,YSV%2 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 ERD OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT Owens Corning One Owens Corning Parkway Toledo, OH 436S9 Evaluation Report 037940.02.12 FL10674-R6 Date of Issuance: 02/06/2012 SCOPE: This Evaluation Report is issued under,Rule 9N-3 and,the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2010 FBC and 2010 FBC Residential Volume sections noted herein. DESCRIPTION: Owens Corning AsphaCt`Roof Slhinglesi LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation' changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated, Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report Is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for Inspection at the job site at the request of the Building Official. i This Evaluation Report consists of pages 1 through 6. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by RobertNiemmen, P.E. on 02/06/2012 This does not serve as an electronically signed document Signed, sealed hardcopies have been transmitted to [he Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinityiERD does not have, nor', does it Intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates! 2. TrinitylERD Is not owned, operated or controlled by any company - manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial Interest In any company manufacturing or distributing products for which the evaluation reports are being Issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity, involved in the approval process of the product. ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: beglion Property Standard Year 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2007 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161, Class F 2006 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158, Class H 2O07 3. REFERENCES: Entity Examination Reference Date UL (CER1739) Physicals & Wind Resistance File R2453, Vol. 3 02/15/2007 UL (TST1740) Physical Properties 06CA20263 04/18/2006 Miami -Dade (CER1592) FBC HVHZ Compliance 07-1116.12 02/14/2008 Miami -Dade (CER1592) FBC HVHZ Compliance 09-0915.12 12/16/2009 Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.09 10/27/2010 Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.10 10/27/2010 Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.08 10/27/2010 Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.07 10/27/2010 Miami -Dade (CER1592) FBC HVHZ Compliance 11-0411.03 06/16/2011 Miami -Dade (CER1592) FBC HVHZ Compliance 11-0919.05 10/13/2011 UL (QUA3743) Quality Control Service Confirmation Exp. 09/26/2014 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic° and Supreme® are fiberglass reinforced, 3-tab asphalt roof shingles. 4.1.2 Berkshire° are fiberglass reinforced, 4-tab asphalt roof shingles. 4.1.3 f� ration(6,) Duration® Premium, Oakridge° and WeatherGuard® HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Berkshire® Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant and WeatherGuard° HP Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.3 Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ. 5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.3 Wind Classification: 5.3.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for us in all wind zones up to Vasd = 150 mph (Vint = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. Exterior Research and Design, LLC. Evaluation Report 037940.02.12 CertlflcateofAuthorization #9503 FL10674-R6 Date of Issuance: 02/06/2012 Page 2 of 6 f TRINITY j ERD 5.3.2 All Owens Corning hip & ridge shingles and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating_ the shingles are acceptable for us in all wind zones up to Vasd = 150 mph (V„n = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.3.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations: Contact the shingle manufacturer for data specific to each shingle. 5.3.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.4 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 9N-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval, or. be Locally Approved per Rule 9N-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the 'manufacturer's current published Instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: ➢ Berkshire® shingles require minimum five (5) nails per shingle. ➢ WeatherGuard® HP shingles require minimum six (6) nails per shingle. ➢ Starter Strip Plus requires minimum five (5) nails per strip. Refer to Owens Corning publishedinformation on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. 6.2.5 Minimum Nailing - Classic® & Supreme: Hounsf Mmard a Atom pay VW" Ams Htoh wind dssvams Y Arw psn vlsntoi oarmshs Aroma vk fwrtss e'Esposun Exterior Research and Design, LLC. Certificate ofAuthorizatlon #9503 Am pme MaduAmn Htih MwtwdorYY Arw pam Www" nommOss Anse visntos fwras r p r r: t6 r �. i SM E:posurs Eigrosi06» Evaluation Report 037940.02.12 FL10674-R6 Date of Issuance:02/06/2012 Page 3 of 6 6.2.6 Minimum Nailina - Berkshire@: 6"WA SWP La th do "hdw -ai i I ir OW 'Sw eye 6.2.7 Minimum Nailing - Duration@ & Duration@ Premium: 4 Nall Pattem EsWom do 4 dam SumNIP1139unkV ana wkfth Ar"dedawsSunNaF tr Ir. E. Bqmtn Wpuq.draspostafdn ae.os P4PU19-dd'wV$kft 6.2.8 Minimum Nallina - Oakridae(k: 4 Nall Pat.tam Equam oat 4 d2ws 1. - 14— Ir 6 6ff Expme "vat EApWcOnd*6618pdg Exterior Research and Design, LLC. Certificate ofAuthorlzaUon #9503 '�J TRIjVI'jY (ERD Sealarastrlp La &a d9s:P1kcbr 0 94 ------- 0-0 " 8 8 Vf 8 Vf ew Vf47c ship 610 6 Nag tSbflb1twIK1OU1VN1w patlar E a ME opaNn d.76XV09 Amxr tad, LE SWExpmm Nays SW Epoun 5ffP4f9.dOSW*On Caws 5%fVfj.&aVOOCf& 6 Nall Pam Esquima can 6 davos r ir Ir A 14 1Y CkyNabas 6 SAr UP" BpWd6ad@6V$pd8. I EqWddn do 6 518pdg. Evaluation Report 037940.02.12 F1.10674-116 Date of Issuance: 02/06/2012 Page 4 of 6 6.2.9 Minimum Nailing - WeatherGuard@ HP; u.N. aar n.. vme. i.r.i ssl .rll+f.rr. 6.3 Hip & Ridge Shingles: CYD ININIERD 6.3.1 Installation of Berkshire° Hip and Ridge Shingles, High Ridge, Hip & Ridge with Sealant and WeatherGuardO HP Hip and Ridge Shingles shall comply with the manufacturer's current published instructions, using four (4) nails per shingle.- Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand -sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing - Berkshire@ Hip & Ridge and High Ridge: 6.3.4 Minimum Nailing - Hip & Ridge with Sealant: anti Fig. 27. Hi Wind Fastening Rattem 4 Naib) .rim Shingle nd Discard 2" ZIPExcess 2to 1" Sea' -~ 12 p T ' Faateninvg. 65/s" 5"Exposure Distance 12" Exterior Research and Design, LLC. Certificate of Authorization #9503 Fig. 2 Toplfiew SideView Nails Nails Top Lerr"ed T 1 4' Piece 1' T I I i I j: I JI I I I Evaluation Report 037940.02.12 FL10674-R6 Date of Issuance: 02/06/2012 Page 5 of 6 6.3.5 Minimum Nailing - WeatherGuard@ HP Hip and Ridge: Fig. A 4 4 4— glxtbn Pl=l gWM p A X7 N�I4v 4 4 A I A 1 I I A I i 1 A s'—►I EiposUlY 7. LABELING: FYD I TRINITY ! ERa Fig. C Hip & Ridge Shingle Fastening TopVlew Hallo Nulls 1" ��, 1` 1' 1" 1' V uxpmrQ I t2'� 7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. S. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: Underwriters Laboratories - QUA1743; (414) 248-6409; karen.buchmann@ul.com END OF EVALUATION REPORT' - Exterior Research and Design, LLC. Certifleate of Authorization #9503 Evaluation Report 037940.02.12 FL10674-R6 Date of Issuance: 02/06/2012 Page 6 of 6 FL # FL5259-R15 Application Type Revision Code Version 2010 .Application Status Pending FBC Approval Comments Archived .._ Product Manufacturer POLYGLASS USA Address/Phone/Email 150 Lyon Drive Fernley, NV 89408 (570)384-1230 Ext242 jakins@polyglass.com Authorized Signature James Akins jakins@polyglass.com Technical Representative Steve Wadding Address/Phone/Email 150 Lyon Drive Fernley, NV 98408 (602)363-7139 stevew@polyglass.com Quality Assurance Representative. James Akins Address/Phone/Email 555 Oakridge Road Humboldt Industrial Pkwy Hazleton, PA 18201 (800)894-4563 jakins@polyglass.com Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 1. Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who Robert Nieminen developed the Evaluation. Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 11/30/2012 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL5259 R15 COI Trinity ERD CI - Nieminen.odf Referenced Standard and Year (of Standard) Standard Year ASTM D1970 2001 ASTM D226 2006 ASTM D6164 2005 h"://www.floridabuildin%z.org/pr/Dr am) dtl.aspx?param=wGEVXOwtDgvbSgA4Zp3Crk... 5/23/2012 Florida Building Code Online, Page 2 of 2 ASTM D6222 2002 ASTM G154 2005 ASTM G155 2005 FM 4474 2004 FRSA/TRI07320 2005 TAS 103 1995 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/23/2012 Date Validated 04/25/2012 Date Pending FBC Approval 04/28/2012 Summary of Products FL # Model, Number or Description Name 5259.1 Polyglass Roof Roofing underlayments Underlayments Limits of Use Installation Instructions Approved for use in HVHZ: No FL5259 R15 II er042212FINAL POLYGLASS UNDERLAYMENTS FL5259- R15. df Approved for use outside HVHZ: Yes Verified By: Robert Nieminen PE-59166 Impact Resistant:. N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-622.5 Evaluation Reports Other: 1.) The design pressure in.this FL5259 R15 AE er042212FINAL POLYGLASS UNDERLAYMENTS FL5259- 1115.0f application relates to one particular underlayment system for use under Created by Independent Third Party: Yes foam -on tile systems. Refer to ER Section 5.5.2 for other systems and maximum design pressures. 2.) Refer to ERSection 5 for other limits of use. Back Next Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Convrlaht 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, e-mail addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions regarding DBPR's ADA web accessibility, please contact our Web Master at webmasterOdbor.state.Fl.us. Product Approval Accepts: FOR] OR \ jSFC Eq P,vsszd by vatisign httn://www.floridabuilding.ora/nr/nr ann dtl.asnx?naram=wGEVXOwtDovbSaAaZn3Crk... 5/23/2012 01 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 PHONE: (203) 262-9245 EVALUATION REPORT FAX: (203) 262-9243 Polyglass USA, Inc. Evaluation Report 1332060.02.09-1110 150 Lyon Drive FL5259-R15 Fernley, NV 98408 Date of Issuance: 02/24/2009 Revision 10: 04/22/2012 SCOPE: This Evaluation Report is issued under Rule 9N73 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2010 Florida Building Code sections noted herein. DESCRIPTION: Polyglass _hoof �Underlayments � n $ LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this.Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityiERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in Its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages i through 10. Prepared by: Robert J.M. Nieminen, P.E. Florida Registiation No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nleminen, P.E. on 04/22/2012 This does not serve as an electronically signed document Signed, sealed hardcoples have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinityiERD does not have, nor does it intend to acquire or will it acquire, a financial Interest in any company manufacturing or distributing products it evaluates. 2. TrinityiERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial Interest in any company manufacturing or distributing products for which the evaluation reports are being Issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial Interest in any other entity Involved in the approval process of the product. ti i 4 TRINITY ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements_ and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section 1507.2.3, 1507.3.3, 1507.5.3, 1507.7.3, 1507.8.3, 1507.9.3 Property Physical Properties Standard ASTM D226 Year 2006 1507.2.4, 1507.2.9.2, 1507.3.3, 1507.5.3 Physical Properties ASTM D1970 2001 1507.11.2 Physical Properties ASTM D6164 2005 1507.11.2 Physical Properties ASTM D6222 2002 1504.6 Accelerated Weathering ASTM G154 2005 1504.6 Accelerated Weathering ASTM G155 2005 1504.3.1 Wind Uplift FM 4474 2004 1507.3.3 Installation Practice FRSA/TRI 07320 2005 1523.6.5.2.1 Physical Properties TAS 103 1995 3. REFERENCES: Entity Examination Reference Date FM Approvals (TST 1867) Wind Uplift 3004091 01/12/2000 PRI (TST 5878) Physical Properties PRIO1111 04/08/2002 PRI (TST 5878) Physical Properties PUSA-005-02-01 01/31/2002 PRI (TST 5878) Physical Properties PUSA-013-02-01 12/23/2002 PRI (TST 5878) Physical Properties PUSA-013-02-02 12/23/2002 PRI (TST 5878) Physical Properties PUSA-013-02-03 12/23/2002 PRI (TST 5878) Physical Properties PUSA-018-02-01 07/14/2003 PRI (TST 5878) Physical Properties PUSA-028-02-01 07/13/2005 PRI (TST 5878) Physical Properties PUSA-033-02-01 01/12/2006 PRI (TST 5878) Physical Properties PUSA-035-02-01 09/29/2006 PRI (TST 5878) Physical Properties PUSA-055-02-02 12/10/2007 PRI (TST 5878) Physical Properties PUSA-061-02-02 01/28/2008 PRI (TST 5878) Physical Properties PUSA-076-02-01 02/22/2008 PRI (TST 5878) Physical Properties PUSA-083-02-01 04/14/2008 PRI (TST 5878) Physical Properties PUSA-088-02-01 07/29/2009 MTI (TST 2508) Physical Properties JX20H7A 04/01/2608 MTI (TST 2508) Physical Properties RX14E8A 01/29/2009 ERD (TST 6049) Physical Properties 11752.09.99-1 02/08/2000 ERD (TST 6049) Wind Uplift 11776.06.02 01/16/2003 ERD (TST 6049) Physical Properties 02200.07.03 07/14/2003 ERD (TST 6049) Wind Uplift P1740.01.07 01/04/2007 ERD (TST 6049) Physical Properties P5110.04.07-1 04/11/2007 ERD (TST 6049) Wind Uplift P9260.03.08 03/21/2008 ERD (TST 6049) Physical Properties P13450.08.09 08/13/2009 ERD (TST 6049) Wind Uplift P30540.11.09-R1 11/30/2009 ERD (TST 6049) Physical Properties P33360.06.10 06/25/2010 Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R10 Certificate ofAuthorizatlon #9503 FL5259-R15 Revision 10: 04/22/2012 . Page 2 of 10 2 4. 5. QOTRINITYIERD Entity Examination Reference Date ERD (TST 6049) Physical Properties P33370.03.11 03/02/2011 ERD (TST 6049) Physical Properties P33370.04.11 - 04/26/2011 ICC-ES (EVL 2396) IBC Compliance ESR-1697 11/01/2011 Miami -Dade (CER 1592) HVHZ Compliance NOA Current Polyglass USA Manufacturing Affidavit Products Current 02/18/2009 Polyglass USA P/L Affidavit Mule -Hide Cross Ltg 03/01/2008 Polyglass USA Materials Affidavit Polystick SA Compound 08/18/2011 UL, LLC. (QUA9625) Quality Control File No. R14571, Vol 1 Exp. 11/30/2012 PRODUCT DESCRIPTION: 4.1 Mechanically Fastened Underlavments• 4.1.1 ELASTOBASE is a fiberglass reinforced, SIBS modified bitumen base sheet. 4.1.2 ELAsroBASE P is a polyester -reinforced, SBS modified bitumen base sheet. 4.2 Self -Adhering Underlavments• 4.2.1 POLYSTICK MTS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced with polyolefinic film surface; meets ASTM D1970 and TAS 103. 4.2 2 PoLYSTICK IR-Xe is a nominal -al -mil thick rubberized asphalt waterproofing membrane, glass `�fibe lerr nforced, vhfi-an'aggreg-ate surface; meets ASTM D1970. 4.2.3 POLYSTICK TU is a nominal 100-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a granular surface; meets ASTM D1970 and TAS 103. 4.2.4 POLYSTICK TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a polyester fabric surface; meets ASTM D1970 and TAS 103. 4.2.5 POLYSTICK TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass- fiber/polyester reinforced, with a granular surface; meets ASTM D1970 and TAS 103. 4.2.6 POLYFLEX SAP, POLYFLEX SAP FR, MULE -HIDE SA-APP CAP SHEET AND MULE -HIDE SA-APP CAP SHEET (FR) are a polyester reinforced, APP modified bitumen cap sheets. 4.2.7 DUAL PROTm is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface. 4.2.8 TILE PROTM is .a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface. 4.3 Mechanically Fastened and/or Bonded Underlavments 4.3.1 ELAsToFLEx S6G AND ELASTOFLEX S6G FR are polyester reinforced, SBS modified bitumen cap sheets. 4.3.2 POLYFLEx G AND PoLYFLEx.G FR are polyester reinforced, APP modified bitumen cap sheets. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ. 5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.3 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the AH] for approval based on this evaluation combined with supporting data for the prepared roof covering. Exterior Research and Design, LLC. Certificate ofAuthorizadon #9503 Evaluation Report P12060.02.09-R10 FL5259-R15 Revision 10. 04/22/2012 Page 3 of 10 �,.J � RIMT'ZIiERD 5.4• Allowable roof covers a lied ato the "pried- ment f II s are as Table 1: Root Cover Options Underlayment Asphalt Shingles Nall -On Tile Foam -On Tile Metal Wood Shakes & Slate Shingles Elastobase Yes Yes No Yes Yes Yes Elastobase P Yes Yes No Yes Yes Yes Polystick MTS Yes Yes No Yes Yes Yes Polystick IR-Xe Yes No No No Yes Yes Polystick TU Yes Yes Yes No Yes Yes See 5.4.1 Polystick TU P Yes Yes Yes No Yes Yes See 5.4.1 Polystick TU Plus Yes Yes Yes Yes Yes Yes See 5.4.1 Dual Pro Yes Yes No Yes Yes Yes Tile Pro Yes Yes Yes Yes Yes Yes See 5.4.1 Elastoflex S6G or S6G FR Yes Yes No No Yes Yes Polyflex G or G FR Yes Yes Ye No Yes Yes See 554. i Polyflex SAP or SAP FR Yes Yes Yes No Yes Yes See 5.4.1 Mule -Hide SA-APP Cap Sheet Yes or SA-APP Cap Sheet (FR) Yes Yes See 5.4.1 No Yes Yes 5.4.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives unless tensile adhesion / long term aging data from an accredited testing laboratory is provided. ➢ Polyfoam PolyPro AH160: Polystick TU, Polystick TU P, Polystick TU Plus, Polyflex G, Polyflex G FR, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule - Hide SA-APP Cap Sheet (FR) or Tile Pro. ➢ Dow TileBond: Polystick TU P, Polystick TU Plus, Polyflex SAP or Tile Pro 5.4.2 For nail -on file systems over Polystick MTS, battens are required for loading / staging of the tile. 5.4.3 A 2-ply underiayment system, consisting of Polystick MTS followed by Polystick MTS, TU, TU P or TU Plus, or Polyflex SAP is allowable for use under mechanically attached prepared roof systems. This is not a requirement, but is allowable if a 2-ply underiayment system is desired. Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1110 CertiflCate ofAuthorizatlon #9503 FL5259-R15 Revision 10: 04/22/2012 Page 4 of 10 TRINITY J ERD 5.5 Allowable substrates are noted below: 5.5.1 Direct -Bond to Deck: Polystick, Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: ➢ New untreated plywood; ➢ ASTM D41 primed new untreated plywood; ➢ Existing plywood; ➢ ASTM D41 primed existing plywood; ➢ ASTM D41 primed OSB; ➢ Southern Yellow Pine; ➢ ASTM D41 primed Southern Yellow Pine; ➢ ASTM D41 primed. structural concrete; ➢ Huber Engineered Woods "ZIP System" Panels (designed and installed to meet wind loads for project). Note: Polyg/ass does not require priming of new or existing plywood sheathing. New or existing plywood sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes. Elastoflex S6G or S6G FR in hot asphalt to: ➢ ASTM D41 primed structural concrete. Polyflex G or G FR torch -applied to: ➢ ASTM D41 primed structural concrete. 5.5.2 Wind Resistance for Underlayment Systems in Foam On Tile Aoolications: FRSA/TRI 07320 does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI 07320 and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609.1.5 for determination of design wind pressures. 5.5.2.1 Maximum Design Pressure — -622 5 psf. Deck: Structural concrete to meet project.requirements to satisfaction of AHJ. Primer: ASTM D41 Underlayment: Polyflex G or G FR torch -applied. 5.5.2.2 Maximum Design Pressure = -315 psf. Deck: Structural concrete to meet project requirements to satisfaction of AHJ. Primer: ASTM D41 Underlayment: Polystick TU, Polystick TU P, Polystick TU Plus, Tile Pro, Polyflex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR). 5.5.2.3 Maximum Design Pressure = -135 psf. Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Primer: (Optional) ASTM D41 Joints: Min. 4-inch wide strips of Elastoflex SA-V over all plywood joints. Underlayment: Polystick TU, Polystick TU P, Polystick TU Plus, Polyflex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) Exterior Research and Design, I.I.C. Evaluation Report P12060.02.09-R10 Certificate of Authorisation #9503 FL5259-R15 Revision 10: 04/22/2012 Page 5 of 10 �.l TRINITY IERD 5.5.2.4 Maximum Design Pressure = -90 per. Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AH]. Primer: (Optional) ASTM D41 Underlayment: Polystick TU, Polystick TU P, Polystick TU Plus, Polyflex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) 5.5.2.5 All other direct -deck, adhered Polyglass underlayment systems beneath foam -on tile systems carry a Maximum Design Pressure of -45 psf. 5.5.3 Bond -to -Insulation: ➢ Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: ASTM C1289, Type II, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; DensDeck DuraGuard; DensDeck Prime; or SECUROCK Gypsum -Fiber Roof Board. ➢ Elastoflex S6G or S6G FR in hot asphalt to: DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board. ➢ Polyflex G or G FR torch -applied to: ASTM D41 primed structural concrete; DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board. For Installation under mechanically attached prepared roof coverings, Insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system In accordance with FM 4470, Appendix K or TAS 114, Appendix J. 5.5.4 Bond to Mechanically Attached Base Laver: ➢ Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or Tile Pro self -adhered to: ASTM D226, Type I or II felt; Elastobase; Elastobase P or Mule -Hide Nail Base. ➢ Elastoflex S6G or S6G FR in hot asphalt to: ASTM D226, Type I or II felt; Elastobase; Elastobase P or Mule -Hide Nail Base. ➢ Polyflex G or G FR. torch -applied to: Elastobase; Elastobase P or Mule -Hide Nail Base. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam -on the systems, base layer shall be attached per minimum requirements of FRSA/TRI 07320/8-05 or RAS 120. 5.6 Exposure Limitations: 5.6.1 Elastobase, Elastobase P, shall not be left exposed for longer than 30-days after installation. 5.6.2 Polystick IR-Xe, Dual Pro or Tile Pro shall not be left exposed for longer than 90-days after installation. 5.6.3 Polystick MTS, TU, TU P or TU Plus shall not be left exposed for longer than 180-days after installation. 5.6.4 Polyflex SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure limitation, unless the prepared roof covering is to be adhesive -set tile, in which case the maximum exposure is 30 days. 5.6.5 Elastoflex S6G or S6G FR or Polyflex G or G FR does not have an exposure limitation, unless the prepared roof covering is to be adhesive -set tile (Polyflex G or G FR only), in which case the maximum exposure is 180 days. Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R10 Certificate of Authorisation #9503 FL5259-R15 Revision 10: 04/22/2012 Page 6 of 10 'J TRINITYIERD 5.7 For tile roof installations governed by the FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, use is limited to the following. Reference is made to the FRSA/TRI Technical Brief titled "Florida High Wind Roof Tile Self -Adhered Underlayment Requirements as of 02/14/2011" for limitations for self -adhering underlayments used beneath tile roof systems. Table 2: Tile System Options per FRSA/TRI 07320/8-05 System Underlay Option Section Reference Product(s) 3.02A 1 Batten Modified Cap Sheet Elastoflex S6G or Elastoflex S6G FR; Polyflex G or G FR only System One: 2 3.02B No. 30 / Modified Cap Base Layer: Elastobase; Elastobase P Sheet Top Layer: Elastoflex S6G or Elastoflex S6G FR; Polyflex G Mechanically or G FR Fastened Tile, 4 3.02D No. 30 Elastobase; Elastobase P Unsealed or 5 Self -Adhered Polystick MTS; TU; TU P; TU Plus; Polyflex SAP or SAP FR; Sealed Underlayment 3.02E Underlayment Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR); System Dual Pro; Tile Pro Base Layer: ASTM D226, Type II; Elastobase; Elastobase P; 6 3.02E No. 30 / Self -Adhered Mule -Hide Nail Base Underlayment Top Layer: Polystick MTS; TU; TU P; TU Plus; Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR); Dual Pro; Tile Pro 3.02A 1 Batten Modified Cap Sheet Elastoflex S6G or Elastoflex $6G FR; Polyflex G or G FR only System Two: 2 3.02B No. 30 / Modified Cap Base Layer: Elastobase; Elastobase P Sheet Top Layer: Elastoflex S6G or Elastoflex S6G FR; Polyflex G Mechanically or G FR Fastened Tile, Sealed Self -Adhered Polystick TU; TU P; TU Plus; Polyflex SAP or SAP FR; Mule- Underlayment 4 3.02D Underlayment Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR); Dual System Pro; Tile Pro Base Layer: ASTM D226, Type II; Elastobase; Elastobase P; 5 3.02E No. 30 / Self -Adhered Mule -Hide Nail Base Underlayment Top Layer: Poiystic4 TU; TU P; TU Plus; Polyflex SAP or SAP Fit, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro; Tile Pro i 3.02A Modified Cap Sheet Polyflex G or G FR 2 3.02B No. 30 /'Modified Cap Base Layer: Elastobase; Elastobase P System Four 'A": Sheet Top Layer: Polyflex G or G FR 4 3.0213 Self -Adhered Polystick TU; TU P; TU Plus; Polyflex SAP or SAP FR; Tile Adhesive -Set Tile, Unsealed or Underlayment Pro; Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Sealed Base Layer: ASTM D226, Type II; Elastobase; Elastobase P; Underlayment System 5 3.02E No. 30 / Self -Adhered Mule -Hide Nail Base Underlayment Top Layer: Polystick TU; TU P; TU Plus; Polyflex SAP or SAP FR; Tile Pro; Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR) 1 3.02A No. 30 / Modified Cap Base Layer: ASTM D226, Type II; Elastobase; Elastobase P System Four Sheet Top Layer: Polyflex G or G FR 3 3.02C Self -Adhered Polystick TU; TU P; TU Plus; Polyflex SAP or SAP FR; Tile 'B": Adhesive -Set Underlayment Pro; Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Base Layer: ASTM D226, Type II; Elastobase; Elastobase P; Tile, Sealed Underlayment 4 No. 30 / Self -Adhered Mule -Hide Nail Base System 3.021) Underlayment Top Layer: Polystick TU; TU P; TU Plus; Polyflex SAP or SAP FR; Tile Pro; Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR) Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1110 Cerdi7cate ofAuthorizadon #9503 FL5259-R15 Revision 10: 04/22/2012 Page 7 of 10 a TRINITY 1 ERD 6. INSTALLATION: 6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published Installation requirements subject to the Limitations set forth in' Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 Elastobase Elastobase P or Mule -Hide Nail Base: 6.3.1 Shall be installed in compliance with the codified requirements for ASTM D226, Type II underiayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.3.2 For use in non -tile applications: 6.3.2.1 Reference is made to the current edition of the NRCA Steep -slope Roofing Manual and ARMA recommendations for installing shingle underlayments and flashings 6.3.2.2 Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of 'Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), Dual Pro or Tile Pro, self -adhered, Elastoflex S6G or S6G FR in hot asphalt or Polyflex G or G FR, torch applied. 6.3.3 For use in tile applications, reference is made to Polyglass published installation instructions in conjunction with FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein. 6.4 Polystick MTS IR-Xe TU TU P or TU Plus Polyflex SAP or SAP FR Mule Hide SA APP Cap Sheet or SA-APP Can Sheet (FR) Dual Pro or Tile Pro: 6.4.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.4.2 For non -tile applications: 6.4.2.1 All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) should be back -nailed in selvage edge seam in accordance with Polyglass/ Mule -Hide Back Nailing Guide. Nails shall be corrosion resistant, it gauge ring -shank type with a minimum 1-inch diameter metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back - nailed using the above noted fasteners and spacing, in area marked "nail area, area para clavar" on the face of membrane. The head lap membrane is to cover the area being back - nailed 6.4.2.2 All seal -lap seams (selvage laps) must be firmly rolled with a minimum 28 lb. hand roller to ensure full contact and adhesion. For Dual Pro and Tile Pro, align the edge of the top sheet to the end of the glue pattern (the sheet will overlap the fabric). Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1110 Certificate of Authorization #9503 FL5259-R15 Revision 10: 04/22/2012 Page 8 of 10 �TRIN(jYIERD View of Ovelap Seam of Dual Pro and Tile Pro 6.4.2.3 All over -fabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Polystick TU Plus Tile Underlayment Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Electrometric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic, applied in between the application of the lap. 6.4.2.4 Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details 6.4.2.5 Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, -Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Polystick TU Plus Tile Underlayment Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide' 251 Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic to the area in need of repair, followed by a minimum 6 x 6 inch patch of the Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be installed in a water shedding manner. 6.4.2.6 All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied for the field membrane. Hand rollers are acceptable for rolling of patches, laps (min. 28 lb roller) or small areas of the roof that are not accessible to a large roller or broom. 6.4.3 For tile applications (not allowed for Polystick IR-Xe): 6.4.3.1 -Reference is made to Section 6.4.2 herein in conjunction with FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein, using the instructions noted above as a guideline. 6.4.3.2 For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the tile. Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1110 Certificate ofAuthorization #9503 FL5259-1115 Revision 10: 04/22/2012 Page 9 of 10 `J TRINITY (ERD 6.5 Elastoflex S6G or 16G FR: 6.5.1 Elastoflex S6G or S6G _FR shall be installed in compliance with current Polyglass published installation requirements. For use in nail -on tile applications, reference is made to FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein. 6.5.2 Elastoflex S6G or S6G FR shall be fully asphalt -applied to the substrates noted in Section 5.5. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, and off set end -laps minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge. 6.6 Polyflex G or G FR: 6.6.1 Polyflex G or G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications, reference is made FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein. 6.6.2 Polyflex G or G FR shall be fully asphalt -applied to the substrates noted in Section 5.5. Side laps shall be minimum 3-inch . and end -laps minimum 6-inch wide, and off set end -laps minimum 3 feet from course to course. Side and end laps shall be fully heat -welded and inspected to ensure minimum 3/8-Inch flow of modified compound beyond the lap edge. 6.7 Tile Staging: 6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Polyglass published requirements for tile staging.. 6.7.2 Battens and/or Counter -battens, as required by the the manufacturer and FRSA/TRI 07320/8- 05 must be used on' all roof slopes greater than 7:12. For roof slopes in excess of 61/4:12, precautions should be taken, such as the use of battens, to prevent tile sliding during the loading process. 6.7.3 For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the tile. 6.7.4 The minimum cure time after installation of self -adhering membranes and before loading of roofing tiles is forty-eight (48) hours. 7. LABELING: Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. S. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9: MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL, LLC — QUA9625; (314) 578-3406; k.chancellor@us.ul.com - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R10 Certificate of Authorization #9503 FL5259-RIS Revision 10: 04/22/2012 Page 10 of 10