Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SUBMITTED PAPERS
Date: 4 Fee Due: 09Z- t# Permit # Planning & Development Services Building & Code Regulations Division 2300 Virginia Ave. Fort Pierce, FL 34982 (772)462-1553 St C"Cie �pUntl� SPECIALTY PERMIT APPLICATION ❑ Electrical ❑ Plumbing HVA ❑ Fence ❑ Shed ❑ Demolition as ❑ Siding Seepage 2 for instructions and addi�tionnallppa-p-eyr�►vvorrk required for specialty permits 1. Location/Site Address, Z0 5 ' LJL.c ► 1 D r- lJ 1 �� 2. Parcel IDNumber: ,�3sL_L-_lco c-t' (Doc Township Range Map Page Zoning Land Use Initials Office Use Section _ Only I)" 3. Complete I)escription of Project or Work: (701(rrP Y 2 1nKI -7- 4. Owners Information , 5. Contractors Information n-1I1✓l1 Name: Address: 1 +2o S - Qm n c&3 City: �Y)s�enTf Vea � at : ��, 2 Zip: Z Is� Phone: 346 518Sk 6. Value of Construction: $ © .QJ FL Reg/Cert #: N-ao 14U l County Cert#: of (gam Q Business Name: sery I CQ 4m—cl�l cC vl � - 4 ?"bone: '7CI( 00 Fax: ) 4Z OWNER'S AFFIDAVIT: I certify that all of the information contain i t is plication is correct and that all work will be done in compliance with all applicable- laws regul n o tr ction and zoning. &Ninson PRINT OWNER OR CONTRACTOR NAME � r_ `SI ATU E•'OWNER.OR.CONTRACTOR STATE OF FLORIDA, COUNTY OF R)1O n, ^n `� P \ [ c /\ }/� ACKNOWLEDGED BEFORE ME THIS 1 Q DAY OF 00 201 Z , BY e,C C [lib r c `� i nv v " WHO IS PERSONALLY KNOWN TOME JV OR WHO HAS PRODUCED, _ NTI�'I TI N. SIGNATURE OF NOTA Y COMMISSION NUMBER e", C. VAZI'll cnsS ' • M COMMISSION # k1309 TYPE OR PRINT NAME OF NOTAR -�s�• 'o; EXPIRES:FebrUary2l,2015 Bonded Thru Notary Public Underwriters NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. EXEMPT: A/C -HEAT REPLACEMENT WITH CONTRACT UNDER $7500.00 Revised 04/26/2010 Property Appraiser - St.Lucic Bunty, FL Page 1 of 1 Phillip F Carlini Record: 1 of 1 Property Identification Site Address: 7420 S OCEAN DR 813 Sec/Town/Range: 22 :36S :41 E Map ID: 35/22S Zoning: Ownership and Mailing Owner: Phillip F Carlini Ilona Carlini Address: 7211 Carlyle Crossing West Bloomfield MI 48322 Sales Information Date Price Code Deed 3/17/2005 100 01 WD 4/30/2004 176700 01 WD 1/31/1991 100 01 QC 12/29/1989 100 01 QC 12/1/1983 0 01 CV 6/1/1980 48900 00 CV I] It0lR B (OBI If �OI•IOBB CBlR•OB IDBI (IOU) ]1 PROPERTY RECORD CARD <<Prev Next » Spec.Assmnt Taxes Exemptions Permits Home Print Parcel I D: 3522-604-0044-000-6 ��4UCI� C�G2 Account#: 116034 Land Use: Condo City/Cnty: St Lucie County ' Legal Description SAND DOLLAR VILLAS CONDOMINIUM C- UNIT 813 AND UND PRO- RATA SHAREIN COMMON ELEMENTS (OR 726-169 ; 20 More... Assessment 2011 Final Total Land and Building Book/Page 2011 Final: 174700 Land Value: 0 Acres: 0.02 2263 / 0526 Assessed: 174700 Building Value: 174700 2037 / 2886 Ag.Credit: 0 Finished Area: 1053 SgFt 0726 / 0169 Exempt: 0671 / 1821 Taxable: 0419 / 0654 Taxes: 3554.4 0334/2801 BUILDING INFORMATION 13 Exterior Features 3900 View: Ocean RoofCover: RoofStruct: - View ExtType: X126 - SndDolrVil-B YearBlt: 1980 Frame: Grade: XSAI - SandDVilla I EffYrBlt: 1980 PrimeWall: BS - CB Stucco StoryHght: 0010 - 1 Story No.Units: 1 SecWall: Interior Features BedRooms: 2 Electric: - PrmintWall: - FullBath: 2 HeatType: - AvgHUFI: STD 1/2Bath: 0 HeatFuel: - Prm.Flors: - %A/C: 0 %Heated: 0 %Sprinkled: 0 Special Features and Yard Items Land Information Type Y/S Qty. Units Qual. Cond. YrBlt. No. Land Use Type Measure Depth 1 0400-Condo N -Unit 0 0 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED. http://www.pasle.org/pasle/Prc.asp?prclid=352260400440006 5/16/2012 Project Summary Entire House Service America Air Conditioning 2755 NW 63rd Court, Fort Lauderdale, FL 33309 Phone: 954-979-1100' Fax: 954-977-3591 Web: www.serviceamerica.com Job: 2250921 Date: May 16, 2012 py: Crystal Lovett For: Phillip & Ilona Carlini 7420 S. Ocean Dr. C-813, Jensen Beach, FL 34957 Phone: 248-342-5858 Notes:'PY r! E C " Desi_qn Information Weather: West Palm Beach, FL, US Winter Design Conditions Summer Design Conditions Outside db 47 OF Outside db 89 OF Inside db 70 OF Inside db 75 OF Design TD 23 OF Design TD 14 OF Daily range Relative humidity L 50 % Moisture difference 60 gr/lb. Heating Summary Sensible Cooling Equipment Load Sizing Structure 12847 Btuh Structure 17998 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Central,vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 12847 Btuh Use manufacturer's data n Rate/swing multiplier 0.94 Infiltration Equipment sensible load 16919 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2218 Btuh Ducts 0 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ftz) 1000 1000 Equipment latent load 2218 Btuh Volume (ft') 9000 9000 Air changes/hour 0.45 0.23 Equipment total load 19136 Btuh Equiv. AVF (cfm) 68 35 Req. total capacity at 0.70 SHR 2.0 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade Trade , Model Cond, CA13NA0240OGBA AHRI ref no. Coil FFIENP025007 AHRI ref.noA540984 Efficiency 80 AFUE Efficiency, 11.7 EER, 14 SEER Heating Input 0 Btuh Sensible cooling 16100 Btuh Heating output 0 Btuh Latent cooling 6900 Btuh Temperature rise 0 OF Total cooling 23000 Btuh Actual air flow 819 cfm Actual air flow 819 cfm Air flow factor 0.064 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.89 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .riy 2012-May-1613:18:43 IWrl htsotRight-Sulte® Universal 201212.0.04RSU10533 Page 1 WAWright Soft FPL Heat Loads - CindytJensen Beach 2250921.rup Calc = MJ8 Front Door.faces: N AHRI Certified Reference Number: 4540984 Date: 5/16/2012 Product: Split System: Air -Cooled Condensing Unit, Coil with Blower Outdoor Unit Model Number: CA13NA024****(A,B) Indoor Unit Model Number: FF1 ENP025 Manufacturer: CARRIER AIR CONDITIONING Trade/Brand name: 13 SEER PURON AC Manufacturer responsible for the rating of this system combination is CARRIER AIR CONDITIONING Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air -Conditioning and Air -Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): 23000 EER Rating (Cooling): 11.70 SEER Rating (Cooling): 14.00 * Ratings followed by an asterisk (*) indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org, Air -Conditioning, Heating, click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on on IL"lop1 and Refrigeration Institute which the certificate was issued, which is listed above, and the Certificate No., which is listed below. 02012 Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129816547450721953