HomeMy WebLinkAboutSUBMITTED PAPERS7. Owner Information
Name: 5ercgio D6mingueZ
Address: 1 °7 0 5 VJy Or''"n 9 Ave -
city: 'F'or+ P i e-rLe State: F l-
Zip: 3gC113- Phone: (-T-7z)L16+ a1 of
Planning & Development Services Department
Building & Code Regulation Division oSC4'Y�ppII Av
"* 2300 Virginia Avenue E®
(� Ft. Pierce, FL 34982-5652Tel. 772-462-1553
i APPLICATION FOR ROOF PERMIT COunty
SEE REVERSE SIDE FOR INSTRUCTIONS
1. Location/Site Address: 1705 1nlyonnina Axre Fe -± Pierce -EL 3y99a
2. Parcel ID Number: 2 2 �' �D I — CEO zz — DDD— (0
Office Use
Section Townshi
Range
I Ma Pa a
Zoning
Land Use Initials
Only
3
P42dyl
ASV
4Y 214*
3. Description of Project or Work Activity: e 000 n^ _y(yUA_ &,1t
4. Total Roof Area (square feet): rl DO 5. Roof Pitch: 'F IAi- roof
6. Type of Roof: [ ] Fiberglass Shingle [ ] Concrete Roof Tile
[ ] Tar & Gravel [4 Modified Bitumen
[ ] Wood Shake / Shingle
[ ] Other
[ ] Product Approval required for all types of Roofing Material (2 Sets)
] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product
Approval attached
** Roof Mitigation per F.S. 553.844 will be required.
8. Contractor Information
FL Reg/Cert #:
County Cert #:
Business Name:
Cell Phone:
9. Value of Construction: $
"Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval.
CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be
done in compliance with all applicable laws regulating construction and zoning.
�d7 ®IA) HI�TIA.
ZbMIA) 1E2_ 1DA�
PRINT QUALIFIERS/OWNERS NAME SIGNATURE OF QUXLIFIERIOWNER
STATE OF FLORIDA, COUNTY OF
ACKNOWLEDGED BEFORE ME THIS DAY OF 20j, BY J146 bwl�,f /71
W ERSONALLY KNOWN TOME OR HA DUCED AS IDENTIFICATION
`� Y';y DAWN MILONE
SIGNATURE OF NOTARY TYP RINT NAME OF NOTARY (seal) _*. .*: iu1Y COMMISSION # DD 852587
D a` EXPIRES: March 22, 2013
B
COMMISSION NUMBER
�ndad ThN Notary Puy hl�ic Undanvriters
NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE
FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR
♦TTrmxTTiv DVDnDi,, DVr1nDT%TN11 vnTTR NnTTCF. nu CnMMF.NCEMENT.
Revised 4/26/2010
�.OAWN MII,ANf
Cgr�Mll?iMO # QA t
oI��pI ��ri;� 02 2013 ao�3
hil p"090 Tpry N910TY PAN �0491wr4ere
'1
INSTRUCTIONS
Please complete all information in the space provided. All information must be printed (use black or blue ink
only) or typed. This roof permit application is to be used only for those activities that are not otherwise included
under a primary building -permit. This application may not be used for any activity that includes structural
alteration. Building activities involving structural alteration, in addition to the roof work, must be permitted
through the regular building permit review process. The information to be provided with this application
includes:
1. Location/Site Address
2. Parcel ID Number
3. Description of Project or Work Activity
4. Total Roof Area
5. Type of Roof
6. Owner Information
7.. Contractor Information
8. Value of Construction
Indicate the street address or general location of the
property where the building activity is taking place.
Indicate the tax identification number of the property where
the building activity is taking place.
Completely describe the building activity to take place.
Please indicate if tear -off or shingle over shingle etc.
Indicate total roof area to be affected by this permit. Also
indicate the pitch of the roof, expressed as a_ standard ratio
of run rise.
Indicate the type of roof being repaired or resurfaced.
Indicate the name and address of the owner of the property
on which building activity is taking place.
Indicate the State of Florida registration number (if
applicable), St. Lucie County contractor license number and
the name of the business doing the work.
Indicate the total value of the work to take place. Total cost
of construction includes all material and labor costs
associated with the building/construction activity.
Construction value is used to determine the permit fee. St.
Lucie County reserves the right to question and/or modify
the indicated value of construction if it is demonstrated that
the submitted figures are not consistent with similar types
of construction.
This application can be submitted to St. Lucie County Building and Zoning, 2300.,Virginia Avenue, FortPierce,
FL 34982. All permit applications must be filled out completely before submission. No applications will be
accepted for processing after 4:30 P.M. For assistance in completing this application, please call (772)
462-1553, during regular office hours (8:00 AM - 5:00 PM), Monday through Friday. .
Upon issuance of this permit, required inspections can be scheduled by calling (772) 462-1261.
St. Lucie County Roof Permit Application rev. 3/1/2009
St. Lucie County
Building & Zoning Department
2300 Virginia Avenue
Fort Pierce, Florida 34982
(772)462-1553
OWNER/BUMDER AFFIDAVIT DISCLOSURE STATEMENT
F.S. 489.103 (7) EXEMPTIONS
State law requires construction to be done by licensed contractors. You have applied for a permit under an
exemption to that law. The exemption allows you, as the owner of your property, to act as your own contractor even
though you do not have a license. You must provide direct, on -site supervision of the construction yourself. You
may build or improve farm outbuildings, a one -family or two-family residence or a commercial building at a. cost of
under $75,000.00. The building or residence must be for your own occupancy. It may not be built or substantially
improved for sale or lease. If you sell or lease a building you -have built or substantially'improved your self within
one year after the construction is complete, the law will presume that you built or substantially improved it for sale
or lease, which is a violation of this exemption. You may not hire an unlicensed person to act as your contractor or
to supervise people working on your building; it is your responsibility to make sure that people employed by you
have licenses required by state law and by county or municipal licensing ordinances. You may not delegate the
responsibility for supervising work to a licensed contractor who is not licensed to perform the work being done.
Any person working on your building who is not licensed must work under your direct supervision and must be
employed by you, which means that you must deduct..F.I.C.A. and withholding tax and provide workers'
compensation for that employee, all as prescribed by law. _ Yourconstruction must comply with all applicable laws,
ordinances, building codes, and zoning regulations. Initial S—
I understand that the building official and inspectors are not there to design or give advice on how to meet
the minimum code. Initial D
I understand that as an owner -builder that any contract disputes with sub -contractors and I must be handled
in a civil court with the advice of an attorney. This department will not mitigate any contract disputes.
Initial S_
I understand that -if I compensate any person or company for work performed they are required to be
licensed in this jurisdiction. If for some reason they do not possess a license, I may be responsible and liable for the
cost of the license. Initial .S, `b
I understand that if any person that is unlicensed and uninsured gets injured on my construction project -
they may be entitled to workmen's compensation. I could be held liable for all doctor, lawyer and relate medical
cost, which could include loss of wages during recovery from their injury. Initial `
To qualify for this exemption under this subsection, an owner must personally appear and sign the building
permit application and initial the above.
I hereby acknowledge that I have read and understand the above disclosure statement and that I further
understand that any violation of the terms of the owner/builder exemption shall be reported by the Building and
Zoning Department to the Florida State Department of Professional. Regulation. Signed and acknowledged on this
-LL day of M6(y of 20 J-0Z
9
OwneirlBuilder gignature
F
STATE OF FLO -
COUNTY OF
The f egoing instrument was acknowledged before me this day of 20 /
by is personally known me, or who has
ed as identification.
0AWN l,91t.QNE ...
C_ / :' ' * trtiY Cfi`vits4lFi$I(3U # op
i e of Notary 3 ;
Title: Notary Public sondes ThM Wert Puhf� Nofwltem
fL�t!
Type or Print Name of Notary
Property Appraiser - St.Lucie r�,lnty, FL Page 1 of 1
PROPERTY RECORD CARD
Sergio Dominguez -Belmont Record: 1 of 1
<<Prev Next» Spec.Assmnt Taxes Exemptions Permits Home Print
Property Identification
��UCIEG
Site Address: 1705 Wyoming Ave
ParcellD: 2421-601-0028-000-6 y�W`
Sec/Town/Range: 21 :35S :40E
Account #: 28989
Map ID: 24/21N
Land Use: SF Res
City/Cnty: St Lucie County
Zoning: RS-4
Ownership and Mailing
Legal Description
Owner: Sergio Dominguez -Belmont
Enedina Mejia ORANGE BLOSSOM ESTATES BLK 3 LOT8 (0.24 AC) (OR 1009-
Address: 1705 Wyoming Ave
1376: 2454-2762)
Fort Pierce FL 34982-5798
Sales Information
Assessment 2011 Final Total Land and Building
Date Price Code Deed
Book/Page 2011 Final: 51000 Land Value: 8900 Acres: 0.24
1/4/2006 45500 01 WD
2454 / 2762 Assessed: 51000 Building Value: 42100
4/5/1996 56000 00 WD
1009 / 1376 Ag.Credit: 0 Finished Area: 1436 SgFt
6/12/1989 53500 00 WD
0641 / 0342 Exempt: 26000
3/1/1973 29000 00 CV
0212 / 0250 Taxable: 25000
Taxes: 516.52
BUILDING INFORMATION
Exterior Features
View:
RoofCover:
SA - Asph Shingle
RoofStruct:
GA - Gable
ExtType:
HD+ - HD+
YearBlt:
1958
Frame:
-
Grade:
D+ - D+
EffYrBlt:
1977
PrimeWall:
BS - CB Stucco
StoryHght:
0010 -1 Story
No.Units:
1
SecWall:
-
Interior Features
BedRooms:
3
Electric:
MX - MAXIMUM
PrmintWall:
PF - PF
FullBath:
2
HeatType:
FHA - FredHotAir
AvgHt/Fl:
STD
1/2Bath:
0
HeatFuel:
ELEC - Electric
Prm.Flors:
TZ - Terrazo
%A/C:
0
%Heated:
100
%Sprinkled:
0
Special Features and Yard Items
Land Information
Type
Y/S Qty.
Units Qual. Cond.
YrBlt.
No. Land Use
Type
Measure Depth
3CHT - 3CHT
S 1
1 AV AV
1977
1 0100-SF Res
BI -Front Ft
92.9 110
3CHT - 3CHT
S 1
1 AV AV
1977
SDSF - SITE DEV S-F
Y 1
1 AV AV
2001
THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED
http://www.paslc.org/paslc/prc.asp?prclid=242160100280006 5/18/2012
Planning & Development Services
Building & Code Regulation Division
Permitting Department
2300 Virginia Avenue
Fort Pierce, FL 34982
Phone: (772) 462-1663 Fax: (772) 462-1578
PROPERTY INFORMATION
Address: 1705 WYOMINGAVE
City / State / Zip: FORT PIERCE
Parcel # : 2421-601-0028-000/6
Zoning: IRS 4
APPLICATION INFORMATION
Permit Number: 1205-0245
Activity Type:
Permit Type: Roof
CONTRACTOR INFORMATION
Contractor Name:
Business Name:
Business Addr:
City / State / ZiF
REVIEWS AND COMMENTS
Review Comments
FL 34982
Jurisdiction: St. Lucie County
Lot # : 8 Block: 3
Page 1
Owner(s):
Sergio Dominguez -Belmont
Enedina Mejia
Application Type: Over the Counter Permit
Other Activity:
Stories: 1 Automatic Sprinkler System?
Fax Number - -
Review Type Status Reviewed By Date Started Date Complete Date Released
Front Counter Review Complete Dawn Milone 05/18/2012
Plans Examiner Review Incomplete Joe Cicio 05/23/2012
05/23/2012 1 Commenl THIS PROJECT IS IN A 160 M.P.H. EXPOSURE B ZONE * DETERMINE THE DESIGN PRESSURES
FOR THE 3 ROOF ZONES [ P-1, P-2 AND P-3 ] * SUBMIT 2 FULLY DIMENSIONED ROOF
SCHEMATICS SHOWING ROOF LAYOUT WITH THE ASSOCIATED DESIGN PRESSURES FOR
EACH ZONE.
05/23/2012 2 Commenl SELECTTHE SYSTEM NUMBER YOU ARE PROPOSING FROM THE PRODUCTAPPROVAL
SHEETS * THE PRESSURE FOR THE SYSTEM NUMBER MUST MEET OR EXCEED THE
CALCULATED DESIGN PRESSURES. ** ELIMINATE ALL OTHER SYSTEM SHEETS NOT USED
FROM THE APPROVALS **
05/23/2012 3 Commenl COMMENTS MAILED AS OF THIS DATE
To Be Review by Plans Exan Complete Joe Cicio 05/23/2012 06/23/2012
.Florida Building Coy' ---Online Page 1 of 2
Y ABC
ForcaCE dff tak4 BCIS Home !Log In I User Registration Hot Topics ' Submit Surcharge I Stats & Facts Publications FBC Staff
Busines�,
Professib%a� Product Approval.
USER: Public User
Regulation
MMMMEMM Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
201-' 02Y5'
ST. LUCIE COU -
BUILDING DIVIMMcategory
REVIEWED
FOR CQMBL1 Compliance M thod
REVIEWED BY
DATE
PLANS AND PERMIT
MUST BE KEPT ON JOB OR
NO INSPECTION WILL BE MADE
In-ImAr or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
FL1654-R10
Revision
2010
Approved ,,
1
L��� p®r-"y
POLYGLASS USA
150 Lyon Drive
Fernley, NV 89408
(570) 384-1230 Ext242
jakins@polyglass.com
James Akins
jakins@polyglass.com
James Arnold, PE, RRO
10475 Park Meadows Drive
Suite 600
Lone Tree, CO 80124
(720) 279-2348
jarnold@polyglass.com
James Akins
555 Oakridge Road
Humboldt Industrial Pkwy
Hazleton, PA 18201
(800)894-4563
jakins@polyglass.com
Roofing
Modified Bitumen Roof System
Evaluation Report from a Florida Registered I
Professional Engineer
Evaluation Report - Hardcopy Received
Robert Nleminen
PE-59166
Underwriters Laboratories Inc.
11/30/2012
John W. Knezevich, PE
Validation Checklist - Hardcopy Received
FL1654 R10 COI Trinity ERD CI - Nieminen.
Standard
ASTM D6163
hftp://www.floridabuilding.org/pr/pr_appjtl.aspx?patam=wG... 5/18/2012
Florida Building. Coy' - 7nline
Page 2 of 2
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
ASTM D6164
ASTMD6222
FM 4470
FM 4474
Method 1 Option D
12/09/2011
12/10/2011
12/20/2011
01/31/2012
Summary of Products
FL #
Model, Number or Name
Description
1654.1
Polyglass SBS and APP Modified .SBS
M
and APP modified bitumen roof syst
Bitumen Roof Systems
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL1654 R10 II Al ER120611FINAL P(
R10. df
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-622.5
Created by Independent Third Party: Ye
Other: 1.) The design pressure in this application
Evaluation Reports
relates to one particular assembly over concrete deck.
FL1654 R10 AE ER120611FINAL POL`r
R10. df
Refer to the ER Appendix for other systems and deck
types. 2.) Refer to ER, Section 5 for other Limits of Use.
Created by Independent Third Party: Ye
Back Next
Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-18:
The State of Florida is an AA/EEO employer. Copyright 2007-2010 State of Florida.:: Privacy Statement :: Aca
Statement
Under Florida law, e-mail addresses are public records. If you do not want your e-mail address released in respon<_
not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any
web accessibility, please contact our Web Master at webmasteradbor. state. fl.us.
Product Approval Accepts:
go ®R®
securif MHt UCS
a
r�ac.xd Ly Va=��in
I
http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wG... 5/18/2012
�� TRINII"YlER
1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE
Deck Application Tvn
1A=1
Wood
New
or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
4
IA-2
Wood
New,
Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
5
1B
Wood
New,
Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
6
1C
Wood
New,
Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
6
1D
Wood
New,
Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
7
1E
Wood
New
or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
8-9
2A
Steel or Conc. New, Reroof (Tear -Off) or Recover B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
SO
l 213
Steel or Conc. New, Reroof (Tear -Off) or Recover C
Mech. Attached Insulation, Bonded Roof Cover
10
-1 2C
Steel or Conc. New, Reroof (Tear -Off) or Recover D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
it
3A-1 Concrete New or Reroof (Tear -Off) A-1
Bonded Insulation, Bonded Roof Cover
12-15
3A-2 Concrete New or Reroof (Tear -Off) A-1
Bonded Temporary Roof, Bonded Insulation, Bonded Roof Cover
16
3B
Concrete New or Reroof (Tear -Off) F
Non -Insulated, Bonded Roof Cover
17
4A
LWIC New or Reroof (Tear -Off) A-1
Bonded Insulation, Bonded Roof Cover
18-19
4B
LWIC New or Reroof'(Tear-Off) A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
19
4C
LWIC New or Reroof (Tear -Off) E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover.
20-23
5A
CWF New or Reroof (Tear -Off) A-1
Bonded Insulation, Bonded Roof Cover
24
513
CWF New, Reroof (Tear -Off) or Recover A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
25
5C
CWF New, Reroof (Tear -Off) or Recover B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
25
5D
CWF New, Reroof (Tear -Off) or Recover C
Mech. Attached Insulation, Bonded Roof Cover
26
SE
CWF New, Reroof (Tear -Off) or Recover E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
26
6A
Gypsum New or Reroof (Teas -Off) A-1
Bonded Insulation, Bonded Roof Cover
27
6B
Gypsum New, Reroof (Tear -Off) or Recover A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
28
6C
Gypsum New, Reroof (Tear -Off) or Recover C
Mech. Attached Insulation, Bonded Roof Cover
28
6D
Gypsum New, Reroof (Tear -Off) or Recover E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
28
7A
Various Recover A-1
Bonded Insulation, Bonded Roof Cover
29-30
713
Various Recover F
Non -Insulated, Bonded Base Sheet, Bonded Roof Cover
30
= The
1.
2.
3.
following notes apply to thesystems outlined herein:
Roof decks shall be in accordance with FBC requirements to the satisfaction of the AH]. Wind load resistance of the roof deck shall be documented through
proper codified and/or FBC Approval documentation.
Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement:
> Wood: Minimum 0:75-Inch penetration.
> Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck.
> Concrete: Minimum 1-Inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions.
Unless otherwise noted, insulation may be any one layer or combination of polyisocya n u rate, polystyrene, wood fiberboard, perlite, DensDeck, DensDeck
Prime, DensDeck DuraGuard, SECUROCK Gypsum -Fiber Roof Board or SECUROCK Glass -Mat Roof Board that meets the QA requirements of F.A.C. Rule
9N-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC 2603.4.1 or 2603.6, when installed with the roof cover.
Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report P9290.02.08-R8 for FL1654-RlO
Certificate of Authorization #9503 Revision 8: 12/06/2011
Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 1 of 30
T'RIfITY ERD
4 Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D (mechanically
`4 tta`shetl' base sheet, bonded roof cover), whereby the base sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck.
.he+structural deck shall be of equal or greater configuration to the steel and concrete deck listings.
5` Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall
expand as noted in the manufacturer's published instructions.
> HA (HA): Full coverage at 25-30 Ibs/square.
D Dow Insta-Stik Roofing Adhesive (D-IS): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c.
• Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons, 12-Inch o.c.
• OMG OlyBond 500 (06500): Continuous 0.75 to 1-Inch wide ribbons, 12-Inch o.c. (PaceCart or SpotShot). Note: OlyBond Green may be used
where OlyBond 500 is referenced.
• OlyBond Classic (OB Classic): Full coverage at 1 gal/square.
> 3M CR-20: Continuous 2.5-3.5-inch wide ribbons, 12-inch o.c. Note: TITESET may be used where CR-20 is referenced.
• Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon -applied adhesive, adhesive ribbons shall be staggered from layer -to -layer a distance of
one-half the ribbon spacing.
• Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing.
6. Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyan u rate at the following thickness
limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to 'increase' the MDP
listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may
be used as a drop -in for the equivalent thicker material listed in the table:
D Millennium One Step Foamable Adhesive (M-OSFA): MDP -157.5 psf (Min. 0.5-inch thick)
OMG OlyBond 500 (013500): MDP -45.0 psf (Min. 0.5-inch thick Multi -Max FA-3)
• OMG OlyBond 500 (O13500): MDP -197.5 psf (Min. 0.5-inch thick ISO 95+ GL)
• OMG OlyBond 500 (013500): MDP -315.0 psf (Min. 0.5-inch thick ENRGY 3)
• OMG OlyBond 500 (013500): MDP -487.5 psf (Min. 0.5-inch thick ACFoam II)
• 3M CR-20: MDP -117.5 psf (Min. 1.0-inch thick)
7. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft.
8. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the
Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified
design professional to resist the elevated pressure criteria. Commonly used methods are PAS 117 'and FM LPDS 1-29. Assemblies marked with an
asterisk* carry the limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3 enhancements.
9. For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in
accordance with FBC Chapter 16, and no rational analysis is permitted.
10. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design
professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105
or ANSI/SPRI FX-1.
11. For existing substrates in a bonded recover installation, the existing roof system shall be examined for compatibility and bond performance with the
selected adhesive, and the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction .of the AHJ, as
documented through field uplift testing in accordance with ASTM E907, FM LPDS 1-52, ANSI/SPRI IA-1 or TAS 124.
12. For Recover Applications using System Type D, the insulation is optional; however, the existing roof system shall be suitable for a recover application.
Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report P9290.02.08-118 for FL1654-R30
Certificate of Authorization #9503 Revision 8: 12/06/2011
Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 2 of 30
13. Unless , the isemoted, refer to the following references for bonded base, ply or cap sheet applications.
YiERD
Table 1: Polyglass Roof Covers
Reference
Layer
Material
Application
BP -AA
Base
Polyglass G2 Base, Modibase, FBC Approved ASTM D4601, Type II
HA at 20-40
(Base and Ply sheets,
Asphalt -Applied)
Ply.
FBC Approved ASTM D2178, Type IV or VI or ASTM D4601, Type II
Ibs/square
SBS-AA
Base or Ply
Elastobase, Elastobase Poly, Elastoflex V, Elastoflex S6
(SBS, Asphalt -Applied)
HA at 20-40
Ibs/square
Cap
Elastoflex S6, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, Elastoshield TS-G FR, Polyfresko
MOP; Polyfresko MOP FR
SBS-TA
Base or Ply
Elastoflex V, Elastoflex S6
Cap
Elastoflex V, Elastoflex S6, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, Elastoshield TS-G
(SBS, Torch -Applied)
Torch -Applied
FR, Polyfresko MOP, Polyfresko MOP FR
SBS-SA
Base
, Elasto_ff ii SA V'Base, Elastoflex SA V FR Base, Elastoflex SA V Plus, Elastoflex SA V Plus FR
(SBS, Self -Adhering)
Cap
Elastoflex SA P, Elastoflex SA P FR, Polyfresko SBS SAP, Polyfresko SBS SAP FR
Self -Adhering
APP-TA
Base. or Ply
Polyflex, Polybond
(APP, Torch -Applied)
)
Cap
Polyflex, Polyflex G, Polyflex G FR, Polybond, Polybond G, Polyfresko Torch, Polyfresko Torch FR
Torch Applied
APP-SA
(APP, Self -Adhering)
Cap
P.olyfle� x SAP, Pplyflex SA P FR, Polyfresko APP SAP, Polyfresko APP SAP FR, Polykool, Polybianko
�-�---�
Self -Adhering
14. Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind load performance. Refer
to current Roofing Materials Directory for fire ratings associated with coating usage.
➢ PG200 Non Fibered Roof Coating or Mule -Hide 111 Non-Fibrated Roof Coating;
➢ PG300 Fibered Roof Coating or Mule -Hide 102 Fibrated Roof Coating;
➢ PG600 Non-Fibered Aluminum Roof Coating..or Mule -Hide 416 Standard Non-Fibrated Aluminum Roof Coating;
➢ PG650 Fibered Aluminum Roof Coating or Mule -Hide 406 Standard Fibrated Aluminum Roof Coating;
➢ PG700 White Reflective Roof Coating;
➢ PG800 Non-Fibered Asphalt Emulsion Roof Coating or Mule -Hide 311 Emulsion Non-Fibrated;
➢ PG850 Fibered Asphalt Emulsion Roof Coating or Mule -Hide 301 Emulsion Fibrated;
➢ Polyplus 60 Premium Non-Fibered Aluminum Roof Coating or Mule -Hide 410 Premium Nan-Fibrated Aluminum Roof Coating;
➢ Polyplus 65 Premium Fibered Aluminum Roof Coating or Mule -Hide 401 Premium Fibrated Aluminum Roof Coating;
➢ Polybrite 70 White Elastomeric Roof Coating.
15. The following represent priming requirements for gypsum -based coverboards:
➢ DensDeck and DensDeck Prime shall be field -primed with PG100 .prior to self -adhering or torch -applied membrane application. No priming is required for hot -asphalt
. membrane applications.
➢ SECUROCK Gypsum -Fiber Roof Board or DensDeck DuraGuard do not require field priming for any membrane application.
16. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609.1.5
for determination of design wind loads.
Exterior Research and Design, LLC. d/b/a TrinitylERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report P9290.02.08-R8 for FL1654-R10
Revision 8: 12/06/2011
Appendix 1, Page 3 of 30
�INIIY1ERD
TABLE SA-1: WOOD DECKS — NEW CONSTRUCTION or REROOF (Tear -Off)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER -
System
Anchor Sheet
Base Insulation
Top Insulation
Roof Cover
MDP
No.
Roof Deck
Type
Fasteners
Attach
Type
Attach
Type
Attach
.Base
Ply
Cap
(psf)
Min. 19/32-inch
Elastobase, Elastobase
32 ga., 1-
8-inch o.In c.
4-inch lap
(Optional)
Min. 0.25-inch
DensDeck, DensDeck
plywood'at max.
Poly, Polyglass G2
Base, CertainTeed
5/8-Inch
diameter tin
and 8-inch
FBC
Approved,
Prime, SECUROCK
(Optional)
SBS-AA,
W-1
24-inch spans
attached 6-inch
Glasbase, Firestone
caps with 11
o.c. in three,
equally
ASTM C1289,
HA
Gypsum -Fiber Roof
Board, Min. Inch
HA
BP -AA or
SBS-AA
BP -AA or
SBS-TA,
-52.5
o.c. with 8d
MB Base JM Perma-
'
ga. annular
spaced,
type II
or mi
FescoBoard or min.
SBS-AA
APP-TA
common nails
Ply 28, Tamko Glass
ring shank
staggered
polyiso-
0.5-inch Structodek
Base or GAFGLAS #75
nails
center rows
cyanurate
HD Fiberboard
Min. 19/32-inch
Elastobase, Elastobase
32 ga. 1-
'
8-inch o.c. in
4-inch lap
(Optional)
(Optional)
plywood at max.
Poly, Polyglass G2
Base, CertainTeed
5/8-inch
diameter tin
and 8-inch
FBC
Approved,
Min. 0.25-inch
DensDeck, DensDeck
One or
more
SBS-SA,
APP-SA,
W-2
24-inch spans
attached 6-inch
Glasbase, Firestone
caps with 11
o.c. in three,
.
equally
ASTM C1289,
HA
Prime, SECUROCK
HA
SBS-SA
SBS-SA,
SBS-TA or
-52.5
o.c. with 8d
MB Base, JM Parma-
ga. annular
spaced,
type II
Gypsum -Fiber Roof
SBS-TA or
APP-TA
common nails
Ply 28, Tamko Glass
ring shank
staggered
polyiso-
Board
APP-TA
Base or GAFGLAS #75
nails
center rows
cyanurate
Min. 19/32-inch
32 ga., 1
8-inch o.c. in
(Optional)
Min. 0.25-inch
plywood at max.
Polyglass G2 Base,
5/8-inch
4-inch lap
FBC
DensDeck, DensDeck
24-Inch spans
CertainTeed Glasbase,
diameter tin
and 8-inch
Approved,
Prime, SECUROCK
(Optional)
SBS-AA,
W-3
attached 4-inch
Firestone MB Base, ]M
caps with 11
o.c. In three,
ASTM C1289,
HA
Gypsum -Fiber Roof
HA
BP -AA or
BP -AA or
SBS-TA,
-60.0
o.c. with 8d
Perma-Ply 28, Tamko
ga. annular
equally
type II
Board, Min. 0.75-inch
SBS-AA
SBS-AA
APP-TA
common nails or
Glass Base or
ring shank
spaced,
polyiso-
FescoBoard or min.
6-inch o.c. with
GAFGLAS #75
nails
staggered
cyanurate
0.5-inch Structodek
#8 screws
center rows
HD Fiberboard
Min. 19/32-inch
plywood at max.
Polyglass G2 Base,
32 ga., 1-
5/8 inch
8-inch o.c. in
4-inch lap
(Optional)
FBC
Min, 0.25 inch
(Optional)
24-Inch spans
CertainTeed Glasbase,
diameter tin
and 8-inch
Approved,
DensDeck, DensDeck
One or
more
SBS-SA,
APP-SA,
W-4
attached 4-inch
Firestone MB Base, JM
caps with 11
o.c. in three,
ASTM C1289,
HA
Prime, SECUROCK
HA
SBS-SA
SBS-SA,
SBS-TA or
-60.0
o.c. with 8d
common nails or
Perma-Ply 28, Tamko
Glass Base or
ga. annular
equally,
spaced,
type II
Gypsum -Fiber Roof
SBS-TA or
APP-TA
6-Inch o.c. with
GAFGLAS #75
ring shank
nails
staggered
polyiso-
cyanurate
Board
APP-TA
#8 screws
center rows
Min. 19/32-inch
32 ga., 1-
6-inch o.c. in
D-IS,
plywood at max.
5/8-Inch
4-Inch lap
Min. 2-inch
OB500, CR-
Min. 0.25-inch
24-inch spans
attached 4-inch
Elastobase or
diameter tin
and 6-inch
o.c. in four,
ACFoam II,
III, H-Shield,
20 or M-
DensDeck, DensDeck
D-IS,
BP -AA or
(Optional)
SBS-AA,
W-5
o.c. with 8d
Elastobase Poly
caps with 12
equally
H-Shield CG,
OSFA, atop
Prime or SECUROCK
CR-2oBso0,
CR-20 or
SBS-AA
BP -AA or
SBS-TA,
-60.0
common nails or
ga. annular
spaced,
Multi -Max FA3
fastener
Gypsum -Fiber Roof
M-OSFA
SBS-AA
APP-TA
6-inch o.c. with
ring shank
nails
staggered .
or ENRGY-3
rows, 7-
inch oc
Board
#8 screws
center rows
Min. 19/32-inch
plywood at max.
32 ga., 1-
6-inch o.c. in
4-inch lap
Min. 2-inch
D-IS,
(Optional)
24-Inch spans
5/8-inch
diameter tin
and 6-inch
ACFoam II,
OB500, CR-
20 or M-
(Optional) Additioal
D-IS,
One or
SBS-SA,
W-6
attached 4-inch
Elastobase or
caps with 12
o.c. in four,
III, H-Shield,
OSFA, atop
layers of base
OB500,
SBS-SA
more
APP-SA
-60.0
o.c. with 8d
Elastobase Poly
ga, annular
equally
H-Shield CG,
fastener
insulation
CR-20 or
SBS-SA,
SBS-TA or
common nails or
ring shank
spaced,
Multi -Max FA3
rows, 7-
M-OSFA
SBS-TA or
APP-TA
6-Inch o.c. with
nails
staggered
or ENRGY-3
inch oc
APP-TA
#8 screws
center rows
I
I
Exterior Research and Design, LLC. d/b/a TrinityjERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report P9290.02.08-RB for FL16S4-R1U
Revision 8: 12/06/2011
Appendix 1, Page 4 of 30
\i TRWITY�ERn
TABLE 1A-2: WOOD DECKS — NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
Anchor Sheet
Base Insulation
Top Insulation
Roof Cover
MOP
No.
Roof Deck
(psf)
Type
Fasteners
Attach
Type
Attach
Type
Attach
Base
Ply
Cap
Elastobase,
OMG Flat
o.c.
Min. 0.25-inch
Min. 19/32-inch
Elastobase Poly,
Bottom Plates
I n 4-inch lap
n 4-inch
(Optional)
DensDeck, DensDeck
plywood at
Polyglass 62 Base,
(square) with
and 12-inch
FBC
Prime, SECUROCK
max. 24-inch
CertainTeed
Roofgrip #14,
o.c. in two,
Approved,
G ypsum-Fiber Roof
BP -AA or
(Optional)
SBS-AA,
W-7
spans attached
Glasbase, Firestone
Dekfast Hex
equally
ASTM C1289
HA
Board, Min. 0.75-
HA
SBS AA
BP -AA or
SBS-TA,
-52.5
6-inch o.c. with,
MB Base, ]M Perma-
with Dekfast
spaced,
type II
inch FescoBoard or
SBS-AA
APP-TA
8d common
Ply 28, Tamko Glass
#14 or TruFast
staggered
polyiso-
min.0.5-inch
nails
Base or GAFGLAS
MP-3 with
center rows
cyanurate
Structodek HD
#75
TruFast HD
Fiberboard
Elastobase,
OMG Flat
12-Inch o.c.
Min. 19/32-inch
Elastobase Poly,
Bottom Plates
in 4-inch lap
(Optional)
plywood at
Polyglass G2 Base,
(square) with
and 12-inch
FBC
Min. 0.25-inch
(Optional)
SBS-SA,
max. 24-inch
CertainTeed
Roofgrip #14,
o.c. in two
Approved,
DensDeck, DensDeck
One or
APP-SA,
W-8
spans attached
Glasbase, Firestone
Dekfast Hex
'
equally
ASTM C1289,
HA
Prime, SECUROCK
HA
SBS-SA
more SBS-
SBS-TA or
-52.5
6-inch o.c. with
MB Base, ]M Perma-
with Dekfast
spaced,
type II
Gypsum -Fiber Roof
SA, SBS-TA
APP-TA
8d common
PI 28, Tamko Glass
y
#14 or TruFast
staggered
polyiso-
Board
or APP-TA
nails
Base or GAFGLAS
MP-3 with
center rows
cyanurete
#75
TruFast HD
Min. 19/32-inch
12-inch o
Min. 0.25-inch'
plywood at
.c.
in 4-inch lap
(Optional)
DensDeck, DensDeck
max. 24-inch
OMG Flat
and 12-inch
FBC
Prime, SECUROCK
spans attached
Elastobase or
Bottom Plates
o.c. in two
Approved,
Gypsum -Fiber Roof
BP -AA or
(Optional)
SBS-AA,
W-9
4-inch o.c. with
Elastobase Poly
(square) with
'
equally
ASTM C1289,
HA
Board, Min. 0.75-
HA
SBS-AA
BP -AA or
SBS-TA,
-60.0
Bd common
Roofgrip #12
spaced,
type II
inch FescoBoard or
SBS-AA
APP-TA
nails or 6-inch
staggered
polyiso-
min. 0.5-inch
o.c. with #8
center rows
cyanurate
Structodek HD
screws
Fiberboard
Min. 19/32-inch
12-inch o.c.
plywood at
in 4-inch lap
(Optional)
max.24-inch
OMG Flat
and 12-inch
FBC
Min 25-inch
0 ..p
(Optional)
(O
SBS-SA,
spans attached
Elastobase or
Bottom Plates
o.c. in two,
Approved,
DensDeck, DensDeck
One or
APP-SA,'
W-10
4-inch o.c. with
Elastobase Poly
(square) with
equally
ASTM C3289,
HA
Prime, SECUROCK
HA
SBS-SA
more SBS-
SBS-TA or
-60.0
Sd common
Roofgrip #12
spaced,
type II
Gypsum -Fiber Roof
SA, SBS-TA
APP-TA
nails or 6-Inch
staggered
polyiso-
Board
or APP-TA
with #8
center rows
cyanu.rate
screws
screws
Exterior Research and Design, LLC. d/b/a TrinitylERD
Certificate of Authorization, #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report P9290.02.08-R8 for FL1654-R10
Revision 8: 12/06/2011
Appendix 1, Page 5 of 30
{�(���ERD
TABLE 1B: WOOD DECKS — NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER
SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
Base Insulation Layer
Top Insulation Layer
Roof Cover
MDP
No.
Roof Deck
(psf)
Type
Fasteners
Attach
Type
Attach
Base
Ply
Cap
Min. 19/32-inch plywood
Min. 1.5-Inch
Dekfast Hex with
Min. 0.75-inch
(Optional if
(Optional if using AA
SBS-AA,
W-il
at max. 24-inch spans
ENRGY 3, H-
Dekfast #12 or
1 per
FescoBoard or min.
HA
using AA Ply)
Base) One or more
SBS-TA,
-52.5
attached 6-inch o.c. with
Shield or
TruFast MP-3 with
1.33 fe
0.5-inch Structodek
BP -AA, SBS-
BP -AA, SBS-AA,
APP-TA
8d common nails
Polytherm
TruFast DP
HD Fiberboard
AA
SBS-TA or APP-TA
Min. 19/32-inch plywood
at max. 24-inch spans
Min. 1.5-inch
Dekfast Hex with
Min. 0.75-inch
(Optional if
(Optional if using AA
SBS-AA,
W-12
attached 4-inch o.c. with
ENRGY 3, H-
Dekfast #12 or
1 per
FescoBoard or min.
HA
using AA Ply)
Base) One or more
SBS-TA,
-60.0
8d common nails or 6-
Shield or
TruFast MP-3 with
1.33 ft Z
0.5-Inch Structodek
BP -AA, SBS-
BP -AA, SBS-AA,
APP-TA
inch o.c. with #8 screws
Polytherm
TruFast DP
HD Fiberboard
AA
SBS-TA or APP-TA
TABLE 1C: WOOD DECKS — NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER
SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
Base Insulation
Top Insulation Layer
Roof Cover
MOP
No.
Roof Deck
Layer Y
(Psf)
Type
Fasteners
Attach
Base
Ply
Cap
Min. 19/32-inch plywood
(Optional)
Min. 0.5-inch Structodek
HD Fiberboard or min.
(Optional if using
W-13
at max. 24-inch spans
One or more layers,
0.25-inch DensDeck,
Dekfast Galvalume
Steel Hex with
1 per
(Optional if
using AA Ply)
AA Base) One or
more BP -AA, SBS-
SBS-AA, SBS-
SBS-
-52.5
attached 6-inch o.c. with
any combination,
DensDeck Prime or
Dekfast #12 DP
1.33 ft'
BP -AA, SBS-AA
AA, SBS-TA or
TA, APP-TA
8d common nails
loose laid
SECUROCK Gypsum -Fiber
APP-TA
Roof Board
Min. 19/32-inch plywood
(Optional)
Min. 0.5-inch Structodek
HD Fiberboard or min.
(Optional if using
at max. 24-inch spans
One or more layers,
0.25-Inch DensDeck,
Dekfast Galvalume
Steel Hex with
1 per
(Optional if
using AA Ply)
AA Base) One or
more BP -AA, SBS-
SBS AA, SBS-
-67.5
attached
attached 4-inch o.c. with
any combination,
DensDeck Prime or
Dekfast #12 DP
1.33 ft2
BP -AA, SBS-AA
AA, SBS-TA or
TA, APP-TA
8d common nails
loose laid
SECUROCK Gypsum -Fiber
APP-TA
Roof Board
Min. 19/32-inch plywood
(Optional)
Min. 0.5-Inch Structodek
HD Fiberboard or min.
(Optional if using
at max. 24-Inch spans
One or more layers,
0.25-inch DensDeck,
Dekfast Galvalume
Steel Hex with
1 per
(Optional if
using AA Ply)
AA Base) One or
more BP AA, SBS-
SBS-AA, SBS-
-82.5
attached 6-inch o.c. with
any combination,
DensDeck Prime or
Dekfast #12 DP
1.33 ftz
BP -AA, SBS-AA
AA, SBS-TA or
TA, APP-TA
#8 screws
loose laid
SECUROCK Gypsum -Fiber
APP-TA
Roof Board
Min. 19/32-inch plywood
(Optional)
Dekfast Galvalume
W-16
at max. 24-inch spans
One or more layers,
Min. 1.5-inch ENRGY 3, H-
Steel Hex with
Dekfast #12 DP or
1 per
SBS-SA
(Optional) One or
more SBS-SA,
SBS-SA, APP-
SA, SBS-TA or
-82.5
attached 6-inch o.c. with
any combination,
Shield or Polytherm
TruFast MP-3 with
1.33 fe
SBS-TA or APP-TA
APP-TA
#8 screws
loose laid
TruFast DP
Exterior Research and Design, LLC. d/b/a Trinity[ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report P9290.02.08-R8 for FL1654-R10
Revision 8: 12/06/2011
Appendix 1, Page 6 of 30
`.P TRINITIF I Eta
TABLE 1D: WOOD DECKS — NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER
SYSTEM TYPE D: PRELIMINARILY ATTACHED INSULATION, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
Insulation Layer(s)
Base Sheet
Roof Cover
� MDP (psf)
Type
Attach
Base
Fasteners
Attach
Ply
Cap
No.
Roof Deck
Min. 19/32-Inch
Elastobase, Elastobase Poly,
Polyglass G2 Base,
OMG Flat Bottom
Plates (square) with
12-inch o.c. in 4-inch
(Optional) One or
plywood at max. 24-
One or more
Prelim.
CertainTeed Glasbase,
Roofgrip #14,
lap and 12-inch o.c.
more BP -AA,
SBS-AA, SBS-
W-17
inch spans attached
layers, any
Attached
Firestone MB Base, JM
Dekfast Hex with
in two, equally
SBS-AA, SBS TA
TA, APP-TA
-52.5
6-inch o.c. with 8d
combination
Perma-Ply 28, Tamko Glass
Dekfast #14 or
spaced, staggered
or APP-TA
common nails
Base or GAFGLAS #75
TruFast MP-3 with
center rows
TruFast HD
OMG Flat Bottom
Min. 19/32-inch
Plates (square) with
12-inch o.c. in 4-Inch
plywood at max. 24-
One or more
Prelim.
Elastobase or Elastobase
Roofgrip #14,
lap and 12-inch o.c.
One or more SBS-
SBS-SA, APP-
W-18
inch spans attached
layers, any
Attached
Poly with poly top surface
Dekfast Hex with
in two, equally
SA, SBS-TA or
SA, SBS-TA or
-52.5
6-inch o.c. with 8d
combination
Dekfast #14 or
spaced, staggered
APP-TA
APP-TA
common nails
TruFast MP-3 with
center rows
TruFast HD
Min. 19/32-inch
plywood at max. 24-
12-inch o.c. in 4-inch
(Optional) One or
W-19
inch spans attached
4-inch o.c. with 8d
One or more
layers, any .
Prelim.
Elastobase or Elastobase
OMG Fiat Bottom
Plates (square) with
lap and 12-inch o.c.
in two, equally
more BP -AA,
SBS-AA SBS-
'
-60.0
common nails or 6-
combination
Attached
Poly
Roofgrip #12
spaced, staggered
SBS-AA, SBS-TA
or APP-TA
TA,'APP TA
inch o.c. with #8
center rows
screws
Min. 19/32-inch
plywood at max. 24-
12-inch o.c. in 4-inch
inch spans attached
One or more
Prelim.
Elastobase or Elastobase
OMG Flat Bottom
lap and 12-Inch o.c.
One or more SBS-
SBS-SA, APP-
W-20
4-inch o.c. with 8d
layers, any
Attached
Poly with poly top surface
Plates (square) with
in two, equally
SA, SBS-TA or
SA, SBS-TA or
-60.0
common nails or 6-
combination
Roofgrip #12
spaced, staggered
APP-TA
APP-TA
Inch o.c. with #8
center rows
screws
Exterior Research and Design, LLC. d/b/a TrinityjEFO
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report P9290.02.08-R8 for FL1654-R10
Revision 8: 12/06/2011
Appendix 1, Page 7 of 30
�� TRINIl1F � ERD
TABLE 1E: WOOD DECKS — NEW CONSTRUCTION or REROOF (Tear -Off)
SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
Roof Deck
Base Sheet
Roof Cover
MDP (psf)
Base
Fasteners
Attach
Ply
Cap
No.
Min. 19/32-inch plywood at
Elastobase, Elastobase Poly, Polyglass
32 ga., inch diameter
8-inch o.c. in 4-inch lap
(Optional) One or
W-21
max. 24-inch spans attached
G2 Base, CertainTeed Glasbase,
with
tin caps with 11 ga. annular
and 8-inch o.c. in
more BP -AA,
SBS-AA, SBS-
-52.5
6-inch o.c. with 8d common
Firestone MB Base, ]M Perma-Ply 28,
ring shank nails
three, equally spaced,
SBS-AA, SBS-TA
TA, APP-TA 4'
nails
Tamko Glass Base or GAFGLAS #75
staggered center rows
or APP-TA
Min. 19/32-inch plywood at
32 ga., 1-5/8-inch diameter
8-inch o.c. in 4-inch lap
(Optional) One or
SBS-SA, APP-
W-22
max. 24-inch spans attached
Elastobase or Elastobase Poly with poly
tin caps with 11 ga. annular
and 8-inch o .c. in
more SBS-SA,
SA, SBS-TA or
-52.5
6-inch o.c. with 8d common
top surface
ring shank nails
three, equally spaced,
SBS-TA or APP-TA
APP-TA
nails
staggered center rows
Min. 19/32-inch plywood at
Elastobase, Elastobase Poly, Polyglass
OMG Flat Bottom Plates
(square) with Roofgrip #14,
12-inch o.c. in 4-inch
(Optional) One or
W-23
max. 24-Inch spans attached
G2 Base, CertainTeed Glasbase,
Dekfast Hex with Dekfast
lap and 12-inch o.c. in
more BP -AA,
SBS-AA, SBS-
52.5
6-Inch o.c. with 8d common
Firestone MB Base, ]M Perma-Ply 28,
or TruFast MP-3 with
two, equally spaced,
SBS-AA, SBS-TA
TA, APP-TA
nails
Tamko Glass Base or GAFGLAS #75
ru Fast HD
TruFast
staggered center rows
or APP-TA
Min. 19/32-inch plywood at
OMG Flat Bottom Plates
(square) with Roofgrip #14,
12-inch o.c. in 4-inch
One or more SBS-
SBS-SA, APP-
W-24
max. 24-inch spans attached
Elastobase or Elastobase Poly with poly
Dekfast Hex with Dekfast
lap and 12-inch o.c. in
SA, SBS-TA or
SA, SBS-TA or
-52.5
6-in6 o.c. with 8d common
top surface
#14 or TruFast MP-3 with
two, equally spaced,
APP-TA
APP-TA
nails
TruFast HD
staggered center rows
Min. 19/32-inch plywood at
max. 24-inch spans attached
Elastobase, Elastobase Poly, Polyglass
32 ga., 1-5/8-inch diameter
8-inch o.c. in 4-inch lap
(Optional) One or
W-25
4-inch o.c. with 8d common
G2 Base CertainTeed Glasbase,
'
tin caps with 11 ga. annular
and 8 inch o.c. in
more BP -AA,
SBS-AA, SBS-
-60.0
nails or 6-inch o.c. with #8
Firestone MB Base, ]M Perma-Ply 28,
ring shank nails
three, equally spaced,
SBS-AA, SBS-TA
TA, APP-TA
Tamko Glass Base or GAFGLAS #75
staggered center rows
or APP-TA
screws
Min. 19/32-inch plywood at
8-inch o.c. in 4-inch lap
max. 24-inch spans attached
Elastobase or Elastobase Poly with poly
32 ga., 1-5/8-Inch diameter
and 8-inch in
(Optional) One or
SBS-SA, APP-
W-26
4-inch o.c. with 8d common
top surface
tin caps with 11 ga. annular
three, equallylly spaced,
more SBS-SA,
SA, SBS-TA or
-60.0
nails or 6-inch o.c. with #8
ring shank nails
staggered center rows
SBS-TA or APP-TA
APP-TA
screws
Min. 19/32-inch plywood at
12-inch o.c. in 4-inch
(Optional) One or
W-27
max. 24-inch spans attached
.c. with
m inch o.c. with Sd common
Elastobase or Elastobase Poly
OMG Flat Bottom Plates
lap and 12-Inch o.c. in
more BP -AA,
SBS-AA, SBS-
-60.0
nails or o.c. with #8
(square) with Roofgrip #12
two, equally spaced,
SBS-AA, SBS-TA
TA, APP-TA
staggered center rows
or APP-TA
screws
Min. '19/32-inch plywood at
12-inch o.c. in 4-inch
W-28
max. 24-inch spans attached
4-inch o.c. with 8d common
Elastobase or Elastobase Poly with poly
OMG Flat Bottom Plates
lap and 12-inch o.c. in
One or more SBS-
SA, SBS-TA or
SBS-SA, APP-
SA, SBS-TA or
-60.0
nails or 6-inch o.c. with #8
top surface
(square) with Roofgrip #12
two, equally spaced,
APP-TA
APP-TA
staggered center rows
screws
Min. 19 32-inch plywood at
/ P y
Elastobase or Elastobase Poly with poly
32 a., 1-5/8-inch diameter
9
4-inch o.c. in 4-inch lap .
and 4-inch o.c. in four,
(Optional) One or
SBS-SA, APP-
W-29
max. 24-inch spans attached
top surface
tin caps with 11 ga. annular
equally spaced,
more SBS SA;
SA, SBS-TA or
-97.5
6-inch o.c. with #8 screws
ring shank nails.
staggered center rows
SBS-TA or APP-TA
APP-TA
Exterior Research and Design, LLC. d/b/a TrinitylERD
Certificate of Authorization #9503
Prepared by: Robert Nfenrl PE-59166
Evaluation Report P9290.02.08-R8 for FL1654-R10
Revision 8: 12/06/2011
Appendix 1, Page 8 of 30
QTRII�II�
T�FEitt
TABLE 1E: WOOD DECKS — NEW CONSTRUCTION or REROOF (Tear -Off)
SYSTEM TYPE E: NON-INSULATEDr MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
Base Sheet
Roof Cover
MDP (psf)
Base
Fasteners
Attach
Ply
Cap
k3O
Roof Deck
Min.
hs plywood at
32 ga., Inch diameter
6-inch o.c. In 4-inch lap
and 6-inch o.c. in four,
(Optional) One or
more BP -AA,
SBS-AA, SBS-
max. 24 inch spans attached
24-in
Elastobase or Elastobase Poly
tin caps with 11 ga. annular
with
equally spaced,
SBS-AA, SBS-TA
TA, APP-TA
-112.5
6-Inch o.c. with #8 screws
ring shank nails
staggered center rows
or APP-TA
32 ga., 1-5/8-inch diameter
6-inch o.c. in 4-inch lap
(Optional) One or
more SBS-SA (no
W-31
Min. 19/32-inch plywood at
max. 24-inch spans attached
Elastobase or Elastobase Poly with poly
tin caps with it ga. annular
ring shank nails. Note: Tin
and 6-inch o.c. in four,
Elastoflex SA V
SBS-SA, APP-
SA, SBS-TA or
-112.5
6-inch o.c. with #8 screws
top surface
caps are to be primed with
equally spaced,
staggered center rows
Base or Elastoflex
SA FR Base),
APP-TA
•
PG100 or. ASTM D41 primer.
SBS-TA or APP-TA
TABLE 1F: WOOD DECKS — NEW CONSTRUCTION or REROOF (Tear -Off)
SYSTEM TYPE F: NON -INSULATED, BONDED ROOF COVER
Roof Cover
System No.
Deck
Primer
MDP (psf).
joint Treatment
Base
Ply
Cap
vMm .19/32 inch -plywood at, -
max 24 mch spans a(fached 6-
f
, f' -
SA _
(.Optional) SBS=SA;;
SBS-SA, APP-SA,ti3
_
( g�0.0�
W-32
rinch_o.c: with 8tling,sharik - '
(Optional) PG100
None .._,
SBS
SBS-TA or APP-TA"
SBS=TA or APP=TA
nails
Min. 15/32-inch. plywood at
Plywood joints are covered with 4-inch
Elastoflex SA V
(Optional) SBS-SA,
SBS-SA, APP-SA,
W-33
max. 24-Inch spans attached 6-
(Optional) PG100
wide strips of Elastoflex SA V Plus, rolled
Base or Elastoflex
SBS-TA or APP-TA
SBS-TA or APP-TA
-97.5
inch o.c. with #12 screws
into place to create continuous bond.
SA V FR Base
Min. 15/32-inch plywood at
Plywood joints are covered with 4-inch
Elastoflex SA V Plus
(Optional) SBS-SA,
SBS-SA, APP-SA,
W-34
max. 24-inch spans attached 6-
(Optional) PG100
wide strips of Elastoflex SA V Plus, rolled
or Elastoflex SA V
SBS-TA or APP-TA
SBS-TA or APP-TA
135.0
inch o.c. with #12 screws
into place to create continuous bond.
Plus FR
Exterior Research and Design, LLC. d/b/a TrinityJERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report P9290.02.08-R8 for FL1654-R10
Revision 8: 12/06/2011
Appendix 1, Page 9 of 30
TABLE 2A: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER
SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
Base Insulation Layer
Top Insulation Layer
Roof Cover
No.
Roof Deck
MOP (psf)
Type
Fasteners
Attach
Type
Attach
Base
Ply
Cap
Min. 22 ga., type B,
Min. 1.5-inch
Dekfast Hex with
Dekfast #14, Trufast
Min. 75-inch 0
.
(Optional if
(Optional if using
AA Base) One or
SBS-AA,
SC-1.
Grade 33 steel or
ACFoam II, E
MP-3 with Trufast HD
1 per 2
FescoBoard or min.
HA
using AA Ply)
more BP -AA, SBS-
SBS-TA,
-45.0*
min. 2,500 psi
� 3, H-Shield orr
or OMG 3-inch Galv
ftZ
0.5-inch Structodek
BP -AA, SBS-AA
AA, SBS-TA or
APP-TA
structrual concrete
Polytherm
Plate with OMD HD
HD Fiberboard
APP-TA.
Min. 22 ga., type B,
Min. 2-inch
Dekfast Hex with
Dekfast #14, Trufast
. Min0.75-inch
(Optional if
(Optional if using
AA Base) One or
SBS-AA,
SC-2.
Grade 33 steel or.
ACFoam II, ENRGY
-3
MP-3 with Trufast HD
1 per 4
FescoBoard or min.
HA
using AA Ply)
more BP -AA, SBS-
SBS-TA,
-45.0*
min. 2,500 psi
3, H-Shield or
or 3-inch Galy
ft�
0.5-inch Structodek
BP -AA, SBS-AA
AA, SBS-TA or
APP-TA
structrual concrete
Polytherm
Plate with OMD HD
HD Fiberboard
APP-TA
Min. 22 ga., type B,
Min. 1.5-Inch
Dekfast Hex with
Min. 0.75-inch
(Optional if
(Optional if using
AA Base) One or
SBS-AA,
SC-3.
Grade 33 steel or
ENRGY 3, H-Shield
Dekfast #14 or
1 per
ft'
FescoBoard or min.
HA
using AA Ply)
more BP -AA, SBS-
SBS-TA,
90.0
min. 2,500 psi
or Polytherm
TruFast MP-3 with
1.33
0.5-inch Structodek
BP -AA, SBS-AA
AA, SBS TA or
APP-TA
structrual concrete
TruFast HD
HD Fiberboard
APP-TA
Min. 22 ga., type B,
Min. 1.5-inch
Dekfast Hex with
Min. 0.75-Inch
BP -AA, SBS-AA
One or more
SBS-SA,
SC-4.
Grade 33 steel or
ENRGY 3, H-Shield
Dekfast #14 or
1 per
FescoBoard or min.
HA
(Top surface
layers, SBS-SA,
APP.-SA,
-90.0
min. 2,500 psi
or Polytherm
TruFast MP-3 with
1.33 ftz
0.5-inch Structodek
primed with
SBS-TA or APP-TA
SBS-TA or
structrual concrete
TruFast HD
HD Fiberboard
PG100 primer)
APP-TA
TABLE 26: STEEL Olt CONCRETE DECKS - NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER
SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
Roof Deck
Base Insulation
Top Insulation Layer
Roof Cover
MOP (psf)
Type
Fasteners
Attach
Base
Ply
Cap
No.
Layer
Y
(Optional)
(Optional if using
Min. 22 ga., type B, Grade
One or more layers,
Min. 0.5-inch
OMG 3-inch Galvalume
1 per
(Optional if using
AA Base) One or
SBS-AA,
SC-5.
33 steel or min. 2,500 psi
SECUROCK Gypsum-
Steel Plate with OMG #14
1 78 ftz
AA Ply) BP -AA,
more BP -AA,
SBS-TA,
-75.0
structrual concrete
any combination,
Fiber Roof Board
HD
SBS-AA
SBS-AA, SBS-TA
APP-TA
loose laid
or APP-TA
Min. 0.5-inch
Structodek HD
Dekfast *Galvalume Steel
(Optional if.using
Min. 22 ga., type B, Grade
One or more layers,
Fiberboard or min.
Hex with Dekfast #12 (steel
1 per
(Optional if using
AA Base) One or
SBS-AA,
SC-6.
33 steel or min. 2,500 psi
any combination,
0.25-inch DensDeck,
only) or #14 or TruFast MP-
1.33 ftz
AA Ply) BP -AA,
more BP -AA,
SBS-TA,
82.5
structrual concrete
loose laid
DensDeck Prime or
3 with TruFast DP (steel
SBS-AA
SBS-AA, SBS-TA
APP-TA
SECUROCK Gypsum-
only) or HD
or APP-TA
Fiber Roof Board
(Optional)
Dekfast Galvalume Steel
(Optional) One
SBS-AA,
Min. 22 ga., type B, Grade
One or more layers,
Min. 1.5-inch ENRGY
Hex with Dekfast #12 (steel
1 per
or more SBS-AA,
SBS-TA,
SC-7.
33 steel or min. 2,500 psi
any combination,
3, H-Shield or
only) or #14 or TruFast MP-
1.33 ftx
SBS-SA
SBS-SA
SBS-SA,
-82.5
structrual concrete
loose laid
Polytherm
3 with TruFast DP (steel
or APP-,
or PP TA
APP-TA,
only) or HD
APP-SA
Exterior Research and Design, LLC. d/b/a TrinitylERD
Certificate of Authorization 09503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report P9290.02.08-118 for FL1654-RIO
Revision 8: 12/06/2011
Appendix 1, Page 10 of 30
TONIC ERD
TABLE 2C: STEEL OR CONCRETE DECKS — NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER
SYSTEM TYPE D: PRELIMINARILY ATTACHED INSULATION, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
NOTE: INSULATION IS OPTIONAL FOR RECOVER APPLICATIONS
System
Insulation Layer(s)
Base Sheet
Roof Cover
No.
Roof Deck
MDP (psf)
Type
Attach
Base
Fasteners
Attach
Ply
Cap
Min. 22 ga., type B,
One or more
Elastobase, Elastobase
OMG Flat Bottom Plates
(square) with Roofgrip
12-inch o.c. in lap and
(Optional) One
SBS-AA,
SC 8.
Grade 33 steel or
min. 2,500 psi
layers, any
Prelim.
Attached
Poly or ]M Perma Ply
#14, Dekfast Hex with
18-inch stag in two, equally
two, a
spaced, staggered center
or more BP -AA,
SBS-AA, SBS-TA
SBS-TA,
-45.0*
structrual concrete
combination
28
Dekfast #14 or TruFast
rows
or APP-TA
APP-TA
MP-3 with TruFast HD
Elastobase, Elastobase
Min. 22 ga., type B,
One or more
Poly, Polyglass G2
Base, CertainTeed
OMG Flat Bottom Plates
(square) with Roofgrip
12-inch stag in 4-inch lap and
(Optional) One
SBS-AA,
SC 9.
Grade 33 steel or
min. 2,500 psi
layers, any
Prelim.
Attached
Glasbase, Firestone
#14, Dekfast Hex with
12-Inch stag in two, equally
spaced, staggered center
or more BP -AA,
SBS-AA, SBS-TA
SBS-TA,
-52.5
structrual concrete
combination
MB Base, JM Perma-
Dekfast #14 or TruFast
rows
or APP-TA
APP-TA
Ply 28, Tamko Glass
MP-3 with TruFast HD
Base or GAFGLAS #75
Min. 22 ga., type B,
One or more
Elastobase or
OMG Flat Bottom Plates
(square) with Roofgrip
12-inch stag in 4-inch lap and
One or more
SBS-SA,
SC-10.
Grade 33 steel or
layers, any
Prelim.
Elastobase Poly with
#14, Dekfast Hex with
12-inch stag in two, equally
SBS-SA, SBS-TA
APP-SA,
-52.5
min. 2,500 psi
combination
Attached
poly top surface
Dekfast or TruFast
spaced, staggered center
or APP TA
SBS-TA or
structrual concrete
h T HD
MP-3 with TruFast HD
rows
APP-TA
Min: 22 ga., type B,
One or more
OMG Flat Bottom Plates
12-inch o.c. in 4-inch lap and
(Optional) One
SBS-AA,
SC-11.
Grade 33 steep or
layers, any
Prelim.
Elastobase or
(square) with Roofgrip
12-inch o.c. in two, equally
or more BP -AA,
SBS-TA,
-60.0
min. 2,500 psi
combination
Attached
Elastobase Poly
#12 (steel only) or #14
spaced, staggered center
SBS-AA, SBS-TA
APP-TA
structrual concrete
rows
or APP-TA
Min. 22 ga., type B,
One or more
Elastobase or
OMG Flat Bottom Plates
12-inch o.c. in 4-inch lap and
One or more
SBS-SA,
SC-12.
Grade 33 steel or
layersany
Prelim.
Elastobase Poly with
(square) with Roofgrip
12-inch stag in two, equally
SBS-SA, SBS-TA
APP SA,
-60.0
min. 2,500 psi
,
combination
Attached
poly top surface
#12 (steel only) or #14
spaced, staggered center
or APP TA
SBS-TA or
structrual concrete.
rows
APP-TA
Min. 22 ga., type B,
Grade 80 steel or
One or more
Prelim.
Dekfast isofast IF-2.375-
12-inch o.c. in the 5-inch
(Optional) APP-
SBS-TA,
SC 13.
min. 2,500 psi
la
layer any
Attached
Poly
AT Plates with Dekfast
wide, heat -welded side lap
TA
APP-TA
-82.5
structrual concrete
combination
#15 HS
Min. 22 ga., type B,
Grade 80 steel or '
One or more
Prelim.
Trufast 2.4 in. Barbed
12-inch o.c. in the 6-inch
(Optional) APP-
SBS-TA,
SC-14,
min. psi
layers, any
Attached
Polybond or Polyflex
Seam Plates with Trufast
wide, heat -welded side lap
TA
APP-TA
-82.5
structrual concrete
structrual
combination
EHD Fasteners
Min. 22 ga., type B,
One or more
Dekfast Hex with Dekfast
12-inch o.c. in the 4-inch lap
(Optional) BP -
SBS-AA,
SC-15.
Grade 33 steel or
layers, any
Prelim.
Polybond, Polyflex or
#14 or OMG Flat Bottom
and 18-inch stag in two,
AA, SBS-AA,
SBS-TA,
-112.5
min. 2,500 psi
combination
Attached
Elastoshield
Plates with OMG Roofgrip
equally spaced, staggered
SBS-TA or APP-
APP-TA
structrual concrete
#14
center rows
TA
Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report P9290.02.08-R8 for FL1654-R10
Certificate of Authorization #9503 Revision 8: 12/06/2011
Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 11 of 30
KJ
�.t 1 KINITYERD
TABLE 3A-1: CONCRETE DECKS — NEW CONSTRUCTION or REROOF (Tear -Off)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
Base Insulation Layer
Top Insulation Layer
Roof Cover
MDP
No.
Deck
Primer
Type I Attach
I Type Attach
Base Ply Cap
(psf)
SELF -ADHERING SYSTEMS WITH BASE INSULATION AND OPTIONAL TOP INSULATION OF THE SAME TYPE:
(Optional)
Min. 1.5-inch H-Shield or Multi-
(Optional) additional
(Optional) One or
SBS-SA, APP-
C-1
Concrete
pG100
Max FA3
D-IS
layers(s) of base insulation
D-IS
SBS-SA
more SBS-SA,
SA, SBS-TA or
-67.5
SBS-TA or APP-TA
APP-TA
(Optional)
Min. 1.5-inch ACFoam II or
(Optional) additional
(Optional) One or
SBS-SA, APP-
C-2
Concrete
pG100
ENRGY 3
D-IS
layers(s) of base insulation
D-IS
SBS-SA
more SBS-SA,
SA, SBS-TA or
-135.0
SBS-TA or APP-TA
APP-TA
Min. 1.5 inch, min. 1.5 pcf EPS
(Optional) additional layers
(Optional) One or
SBS-SA, APP-
C-3
Concrete
None
insulation board
D-IS
of base insulation
D-IS
SBS-SA
more SBS-SA,
SA, SBS-TA or
-157.5
SBS-TA or APP-TA
APP-TA
Min. 1.5-inch, min. 2.0 pcf EPS
(Optional) additional layers
(Optional) One or
SBS-SA, APP-
C-4
Concrete
None
Insulation board
OB500
of base insulation
OB500
SBS-SA
more SBS-SA,
SA, SBS-TA or
-120.0
SBS-TA or APP-TA
APP-TA
l) additional
(Optional)
(Optional) One or
SBS-SA, APP-
C-5
Concrete
None
Min. 1.5-inch ENRGY 3
OB500
of base insulation
OB500
SBS-SA
more SBS-SA,
SA, SBS-TA or
-127.5
SBS-TA or APP-TA
APP-TA
Min. 1.5-inch ACFoam II, or H-
l) additional (Optional)
(Optiona
(Optional) One or
SBS-SA, APP-
C-6
Concrete
None
Shield
OB500
of base Insulation
OB500
SBS-SA
more SBS-SA,
SA, SBS-TA or
-150.0
SBS-TA or APP-TA
APP-TA
Min. 1.5-inch ACFoam II,
(Optional) additional
(Optional) One or
SBS-SA, APP-
C-7
Concrete
None
ENRGY 3, H-Shield or Multi -Max
M-OSFA
layers(s) of base insulation
M-OSFA
SBS-SA
more SBS-SA,
SA, SBS-TA or
-232.5
FA3
SBS-TA or APP-TA
APP-TA
Min. 1.5-inch, min. 2.0 pcf EPS
(Optional) additional layers
(Optional) One or
SBS-SA, APP-
C-8
Concrete
None
insulation board
CR-20
of base insulation
CR-20
SBS-SA
more SBS-SA,
SA, SBS-TA or
-240.0
SBS-TA or APP-TA
APP-TA
Min. 1.5-inch ACFoam II,
(Optional) One or
SBS-SA, APP-
C-9
Concrete
None
ACFoam III, ENRGY 3, H-Shield,
CR-20
(Optional) additional
CR-20
SBS-SA
more SBS-SA,
SA, SBS-TA or
-270.0
H-Shield CG , Multi -Max FA3, or
layers(s) of base insulation
SBS-TA or APP-TA
APP TA
ISO 95+ GL
Min. 2-inch ACFoam II or H
(Optional) additional
(Optional) One or
SBS-SA, APP
C-10
Concrete
None
Shield
OB Classic
layers(s) of base insulation
OB Classic
SBS-SA
more SBS-SA,
SA, SBS-TA or
-270.0
SBS-TA or APP-TA
APP-TA
Min. 1.5-inch ACFoam II,
(Optional) additional
(Optional) One or
SBS-SA, APP-
C-11
Concrete
PG100
ACFoam III, ENRGY 3, H-Shield,
HA
layers(s) of base insulation
HA
SBS-SA
more SBS-SA,
SA, SBS-TA or
-480.0
H-Shield CG or Multi -Max FA3
SBS-TA or APP-TA
APP-TA
SELF -ADHERING SYSTEMS WITH BASE INSULATION AND COVERBOARD:
Min. 0.25-inch SECUROCK
(Optional) One or
SBS-SA, APP-
C-12
Concrete
None
Min. 1.5-inch Multi -Max FA3
D-IS
Gypsum -Fiber Roof Board
D-IS
SBS-SA
more SBS-SA,
SA, SBS-TA or
-67.5
SBS-TA or APP-TA
APP-TA
Min. 1.5-inch, min. 2.0 pcf
Min. 0.25-Inch DensDeck
(Optional) One or
SBS-SA, APP-
C-13
Concrete
None
ASTM C578 Expanded
D-IS
DensDeck Prime
D-IS
SBS-SA
more SBS-SA,
SA, SBS-TA or
-120.0
Polystyrene
SBS-TA or APP-TA
APP-TA
Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report P9290.02.08-R8 for FL1654-R10
Certificate of Authorization #9503 Revision 8: 12/06/2011
Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 12 of 30
'�,J TRINITY � ERD
TABLE 3A-1: CONCRETE DECKS — NEW CONSTRUCTION or REROOF (Tear -Off)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
Base Insulation Layer
Top Insulation Layer
Roof Cover
MOP
No.
Deck
Primer
(Psf)
Type
Attach
Type
Attach
Base
Ply
Cap
C-14
Concrete
None
n.
Min. 2-inch ACFoam II, ENRGY-
D-IS
Min. 0.25-inch SECUROCK
D-IS
SBS-SA
(Optional) One or
more SBS-SA,
SBS-SA, APP-
SA, SBS-TA or
-247.5
3 H-Shield
Gypsum -Fiber Roof Board
SBS-TA or APP-TA
APP-TA
Min. 0.25-inch DensDeck,
(Optional) One or
SBS-SA, APP-
C-15
Concrete
None
Min. 1.5-inch ENRGY 3
OB500
DensDeck Prime
OB500
SBS-SA
more SBS-SA,
SA, SBS-TA or
-127.5
SBS-TA or APP-TA
APP-TA
C-16
Concrete
None
Min. 1.5-Inch ACFoam II, H=
OB500
Min. 0.25-Inch DensDeck,
OB500
SBS-SA
(Optional) One or
more SBS-SA,
SBS-SA, APP-
SA, SBS-TA or
-150.0
Shield or ISO 95+GL
DensDeck Prime
SBS-TA or APP-TA
APP-TA
C-17
Concrete
None
Min. 2-inch ACFoam II, ENRGY-
OB500
Min. 0.25-Inch SECUROCK
OB500
SBS-SA
(Optional) One or
more SBS-SA,
SBS-SA, APP-
SA, SBS-TA or
-247.5
3 or H-Shield
Gypsum -Fiber Roof Board
SBS-TA or APP-TA
APP-TA
Min. 1.5-inch ACFoam II,
Min. 0.25-inch SECUROCK
(Optional) One or
SBS-SA, APP-
C-18
Concrete
None
ENRGY 3, H-Shield or Multi -Max
M-OSFA
Gypsum -Fiber Roof Board
M-OSFA
SBS-SA
more SBS-SA,
SA, SBS-TA or
-232.5
FA3
SBS-TA or APP-TA
APP-TA
C 19
Concrete
None
n.
Min. 2 inch ACFoam II, ENRGY-
M-OSFA
Min. 0.25-inch SECUROCK
M-OSFA
SBS-SA
(Optional) One or
more SBS-SA,
SBS-SA, APP-
SA, SBS-TA or
-247.5
3 H-Shield
Gypsum -Fiber Roof Board
SBS-TA or APP-TA
APP-TA
Min. 1.5-inch, min. 2.0 pcf
Min. 0.25-inch DensDeck,
(Optional) One or
SBS-SA, APP-
C-20
Concrete
None
ASTM C578 Expanded
CR-20
DensDeck Prime
CR-20
SBS-SA
more SBS-SA,
SA, SBS-TA or
-240.0
Polystyrene
SBS-TA or APP-TA
APP-TA
Min. 2-inch ACFoam IV, min.
1.5-inch Ultra -Max or Multi -Max
Min.
(Optional) One or
SBS-SA, APP-
C-21
Concrete
None
FA-3, min. 1.3-inch ACFoam III
CR-20
um-Fibernch Roof Board
Gypsum -Fiber Roof Board
CR-20
SBS-SA
more SBS-SA,
SA, SBS-TA or
-240.0
or min. 1.0-inch ISO 95+GL, H-
SBS-TA or APP-TA
APP-TA
Shield, H-Shield CG or ENRGY 3
C-22
Concrete
None
Min. 2-inch ACFoam II, ENRGY-
CR-20
Min. 0.25-inch SECUROCK
CR-20
SBS-SA
(Optional) One or
more SBS-SA,
SBS-SA, APP-
SA, SBS-TA or
-247.5
3 or H-Shield
Gypsum -Fiber Roof Board
SBS-TA or APP-TA
APP-TA
C-23
Concrete
None
Min. 2-inch ACFoam II or H-
OB Classic
Min. 0.25-inch SECUROCK
OB Classic
SBS-SA
(Optional) One or
more SBS-SA,
SBS-SA, APP-
SA, SBS-TA or
-350.0
Shield
Gypsum -Fiber Roof Board
SBS-TA or APP-TA
APP-TA
Min. 1.5.-inch ACFoam II,
Min. 0.25-inch SECUROCK
(Optional) One or
SBS-SA, APP-
C-24
Concrete
PG100
ACFoam III, ENRGY 3, H-Shield,
HA
Gypsum -Fiber Roof Board
HA
SBS-SA
more SBS-SA,
SA, SBS-TA or
-350.0
H-Shield CG or Multi -Max FA3
SBS-TA or APP-TA
APP-TA
Exterior Research and Design, LLC. d/b/a TrinitylERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report P9290.02.08-R8 for FL1654-R10
Revision 8: 12/06/2011
Appendix 1, Page 13 of 30
TABLE 3A-1 (Continued): CONCRETE DECKS — NEW CONSTRUCTION or REROOF (Tear -Off)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
Base Insulation Layer
Top Insulation Layer
Roof Cover
MOP
No.
Deck
Primer
Type Attach
Type Attach
Base Ply Cap
(PS0
ASPHALT AND/oR TORCH APPLIED SYSTEMS:
Min. 2-inch ACFoam II or
Min. 0.25-inch
(Optional) One or
C-25
Concrete
None
H-Shield
D-IS
SECUROCK Gypsum-
D-IS
BP -AA, SBS-AA
more BP -AA, SBS-AA
SBS-AA
-225.D
Fiber Roof Board
C-26
Concrete
None
Min. 2-inch ACFoam II or
D-IS
Min. 0.25-Inch
SECUROCK Gypsum-
D-IS
APP-TA
(Optional) One or
APP-TA
-232.5
H-Shield
Fiber Roof Board
more APP-TA
C-27
Concrete
None
Min. 2-Inch ACFoam II or
OB500
Min. 0.25-inch
SECUROCK Gypsum-
OB500
BP -AA, SBS-AA
(Optional) One or
SBS-AA
-225.0
H-Shield
Fiber Roof Board
more BP -AA, SBS-AA
C-28
Concrete
None
Min. 2-inch ACFoam II or
OB500
Min. 0.25-inch
SECUROCK Gypsum-
OB500
APP-TA
(Optional) One or
APP-TA
-232.5
H-Shield
Fiber Roof Board
more APP-TA
Min. 2-Inch ACFoam II or
Min. 0.25-inch
(Optional) One or
C-29
Concrete
None
H-Shield
M-OSFA
SECUROCK Gypsum-
M-OSFA
BP -AA, SBS-AA
more BP -AA, SBS-AA
SBS-AA
-225.0
Fiber Roof Board
Min. 2-Inch ACFoam II or
Min. 0.25-Inch
(Optional) One or
C-30
Concrete
None
H-Shield
M-OSFA
SECUROCK Gypsum-
M-OSFA
APP-TA
more APP-TA
APP-TA
232.5
Fiber Roof Board
Min. 2-inch ACFoam IV,
min. 1.5-inch Ultra -Max or
Multi -Max FA-3, min. 1.3-
Min. 0.25-inch
(Optional) One or
C-31
Concrete
None
inch ACFoam III or min.
CR-20
SECUROCK Gypsum-
CR-20
BP -AA, SBS-AA
more BP -AA, SBS-AA
SBS-AA
-225.0
1.0-Inch ISO 95+GL, H-
Fiber Roof Board
Shield, H-Shield CG or
ENRGY 3
Min. 2-inch ACFoam IV,
min. 1.5-inch Ultra -Max or
Multi -Max FA-3, min. 1.3-
Min. 0.25-inch
(Optional) One or
C-32
Concrete
None
inch ACFoam III or min.
CR-20
SECUROCK Gypsum-
CR-20
APP-TA
more APP-TA
APP-TA
-232.5
1.0-inch ISO 95+GL, H-
Fiber Roof Board
_
Shield, H-Shield CG or
ENRGY 3
(Optional) Min. 2-inch
Min. 0.25-inch
(Optional) One or
C-33
Concrete
None
ACFoam II or H-Shield
OB Classic
SECUROCK Gypsum-
OB Classic
BP -AA, SBS-AA
more BP -AA, SBS-AA
SBS-AA
-225.0
Fiber Roof Board
C-34
Concrete
None
(Optional) Min. 2-inch
OB Classic
Min. 0.25-inch
SECUROCK Gypsum-
OB Classic
APP-TA
O
(Optional) One or
APP-TA
-232.5
ACFoam II or H-Shield
Fiber Roof Board
more APP-TA
Min, 1.5-inch ACFoam II,
Min. 0.25-inch
C-35
Concrete
PG100
ACFoam III, ENRGY 3, H-
HA
SECUROCK Gypsum-
HA
BP -AA, SBS-AA
(Optional) One or
SBS-AA
-225.0
Shield, H-Shield CG or
Fiber Roof Board
more BP -AA, SBS-AA
Multi -Max FA3
.
Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report P9290.02.08-RB for FL1654-RlO
Certificate of Authorization #9503 Revision 8: 12/06/2011
Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 14 of 30
ERD
TABLE 3A-1 (Continued): CONCRETE DECKS — NEW CONSTRUCTION or REROOF (Tear -Off)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
Base Insulation Layer
Top Insulation Layer
Roof Cover
MDP
NO.
Deck
Primer
Type Attach
Type Attach
Base Ply Cap
(P)
ASPHALT AND/OR TORCH APPLIED SYSTEMS:
Min. 1.5-inch ACFoam II,
Min. 0.25-inch
C-36
Concrete
PG100
ACFoam III, ENRGY 3, H-
Shield, H-Shield CG or
HA
SECUROCK Gypsum-
HA
APP-TA
-
(Optional) One or
more APP-TA
APP-TA
-232.5
Multi -Max FA3
Fiber.Roof Board
(Optional if using AA
(Optional if using AA
C-37
Concrete
PG100
Min. 0.75-inch FescoBoard
HA
None
N/A
Ply) One or more BP-
Base) One or more
BP -AA, SBS-AA, SBS-
SBS-AA, SBS-
TA, APP-TA
-277 5
AA, SBS-AA
TA or APP-TA
Min. 1.5-inch ACFoam II,
(Optional if using AA
(Optional if using AA
C-38
Concrete
PG100
ACFoam III, ENRGY 3, H-
HA
Min. 0.75-Inch Fesco
HA
Pig) One or more BP-
Base) One or more
SBS-AA, SBS-
-290.0
Shield, H-Shield CG or
Board
AA, SBS-AA
BP -AA, SBS-AA, SBS-
TA, APP-TA
Multi -Max FA3
TA or APP-TA
(Optional if using AA
f using
gape')
C-39
Concrete
PG100
Min. 0.5-inch Structodek
HA
None
N/A
Ply) One or more BP-
Oneonal
SBS AA, SBS-
-285.0
HD Fiberboard
AA, SBS-AA
BP -AA, SBS-AA, SBS-
TA, APP-TA
TA or APP-TA
Min. 1.5-inch ACFoam II,
Min. 0.5-inch
(Optional if using AA
(Optional if using AA
C-40
Concrete
PG100
ACFoam III, ENRGY 3, H-
HA
Structodek HD
HA
Ply) One or more BP-
Base) One or more
SBS=AA, SBS-
-480.0
Shield, H-Shield CG or
Fiberboard
AA, SBS-AA
BP AA, SBS-AA, SBS-
TA, APP-TA
Multi -Max FA3
TA or APP-TA
Min. 1.5-inch ACFoam II,
(Optional if using AA
(Optional if using AA
C 41
Concrete
PG100
ACFoam III, ENRGY 3, H-
HA
Min. 0.25-inch
HA
Ply) One or more BP-
Base) One or more
SBS-AA, SBS-
-480.0
Shield, H-Shield CG or
DensDeck Prime
AA' SBS-AATA
BP -AA, SBS-AA, SBS-
TA, APP-TA
Multi Max FA3
or APP-TA
(Optional if using AA
(Optional if using AA
C-42
Concrete
PG100
Min. 0.25-Inch DensDeck
HA
None
N/A
Ply) more BP-'
One or
OneSBSor
Base) One or more
SBS-AA, SBS-
510.0
Prime
AA,
BP -AA, SBS-AA, SBS-
TA, APP-TA
TA or APP-TA
Exterior Research and Design, LLC. d/b/a TrinityjERD Evaluation Report 139290.02.08-118 for FL1654-R10
Certificate of Authorization #9503 Revision 8: 12/06/2011
Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 15 of 30
TRINITY [ER D
TABLE 3A-2: CONCRETE DECKS — NEW CONSTRUCTION or REROOF (Tear -Off)
SYSTEM TYPE A-1: BONDED TEMP ROOF, BONDED INSULATION, BONDED ROOF COVER
Syste
Temp
Base Insulation Layer
Top Insulation Layer
Roof Cover
MDP
m No.
Deck
Prime
Roof
(P�
Type
Attach
Type
Attach
Base
Ply
Cap
Min. 1.5-inch, min. 2.0 pcf
(Optional if using
polyisocyan u rate base
(Optional)
C-43
Conc
PG100
ElastoFlex
ASTM C578 Expanded
Polystyrene or Min. 1.5-inch
D-IS
insulation) Min. 0.25-inch
D-IS
SBS SA
One or more
SBS-SA, APP-
SA, SBS-TA or
-60.0
SA V Plus
ACFoam IT, ENRGY-3, H-Shield
DensDeck Prime or
SBS-SA, SBS-
APP-TA
or Multi -Max FA3
Gypsum -Fiber
ROtKBoard
TA or APP-TA
RoofSEC
Roof Board
Elastoflex
(Optional if using
SA P or
Min. 1.5-inch; min. 2.0 pcf
polyisocyanurate base
(Optional)
SBS-SA, APP-
C-44
Conc
PG100
Polyglass
ASTM C578 Expanded
D-IS
insulation) Min. 0.25-Inch
D-IS .
SBS-SA
One or more
SA SBS-TA or
-75.0
Base
Polystyrene or Min. 1.5-inch
DensDeck Prime or
SBS-SA, SBS-
APP-TA
(torched)
ACFoam II or ENRGY 3
SECUROCK Gypsum -Fiber
TA or APP-TA
Roof Board
Min. 1.5-inch, min. 2.0 pcf
(Optional if using
ASTM C578 Expanded
polyisocyanurate base
(Optional)
SBS-SA, APP-
C 45
Conc
PG100
Elastoflex
Polystyrene or Min. 1.5-Inch
CR-20
insulation) Min. 0.25-inch
CR-20
SBS-SA
One or more
SA SBS-TA or
-60.0
SA V Plus
ACFoam II, ACFoam III, ENRGY _
DensDeck Prime or
SBS-SA, SBS-
APP TA
3, H-Shield, H-Shield CG, Multi-
SECUROCK Gypsum -Fiber
TA or APP-TA
Max FA3 or ISO 95+GL
Roof Board
Min. 1.5-inch, min. 2.0 pcf
(Optional if using
Polyglass
ASTM C578 Expanded
polyisocyanurate base
(Optional)
SBS-SA, APP-
C-46
Conc
PG100
Base,
Polystyrene or Min. 1.5-inch
CR-20
insulation) Min. 0.25-inch
CR-20
SBS-SA
One or more
SA, SBS-TA or
-75.0
(torched)
ACFoam II, ACFoam III, ENRGY
DensDeck Prime or
SBS-SA, SBS-
APP-TA
3, H-Shield, H-Shield CG, Multi-
SECUROCK Gypsum -Fiber
TA or APP-TA
Max FA3 or ISO 95+GL
Roof Board
Min. 1.5-inch, min. 2.0 pcf
Min. 0.25-inch DensDeck,
(Optional)
SBS-SA, APP-
C-47
Conc
PG100
ElastoFlex
ASTM C578 Expanded
CR-20
DensDeck Prime or
CR-20
SBS-SA
One or more
SA, SBS-TA or
-240.0
SAP
Polystyrene
SECUROCK Gypsum -Fiber
SBS-SA, SBS-
APP-TA
Roof Board
TA or APP-TA
Min. 1.5-inch ACFoam II,
(Optional)
SBS-SA, APP-
C-48
Conc
PG100
ElastoFlex
ACFoam III, ENRGY 3, H-Shield
CR-20
(Optional) Additional layers
CR-20
SBS-SA
One or more
SA SBS-TA or
-250.0
SA P
H-Shield CG, Multi -Max FA3 or
of base insulation
SBS-SA, SBS-
APP-TA
ISO 95+GL
TA or APP-TA
Min. 0.5-inch Temple HD6
Min. 1.5-inch ACFoam II,
or Structodek HD
(Optional)
SBS-SA, APP-
C-49
Conc
PG100
Elastoflex
ACFoam III, ENRGY 3, H-Shield,
CR-20
Fiberboard or min. 0.25-
CR-20
SBS-SA
One or more
SA SBS-TA or
-270.0
SA P
H-Shield CG, Multi -Max FA3 or
inch DensDeck, DensDeck
SBS-SA, SBS-
APP-TA
ISO 95+GL
Prime or SECUROCK
TA or APP-TA
Gypsum -Fiber Roof Board
ElastoFlex
(Optional if
SA V Vent,
Min. 0.25-inch DensDeck or
(Optional if
using AA
SA V Vent.
Min. 1.5-inch ACFoam II,
DensDeck Prime, min. 0.5-
using AA
Base) One or
SBS-AA, SBS-
C-50
Conc
PG100
FR or SA V
ENRGY 3, H-Shield, ISO 95+
HA
inch Structodek HD
HA
Ply) BP -AA,
more BP AA,
TA, APP-TA
-280.0
Plus
GL, Multi -Max FA3 or Polytherm
Fiberboard or min. 0.75-
SBS-AA
SBS-AA, SBS-
followed by
inch Fesco Board
TA or APP-TA
APP-TA
Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report P9290.02.08-R8 for FL1654-R10
Certificate of Authorization #9503 Revision 8: 12/06/2011
Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 16 of 30
TRINIl1F[ERD
TABLE 3B: CONCRETE DECKS — NEW CONSTRUCTION or REROOF (Tear -Off)
SYSTEM TYPE F: NON -INSULATED, BONDED BASE SHEET, BONDED ROOF COVER
Roof Cover
.System No.
Deck
Primer
MOP (psf)
Base
Ply
Cap
C-51
Concrete
PG100
Flex SA V Vent or SA V
Vent FR
Vent
(Optional) SBS-TA or APP-TA
SBS-AA, SBS-TA, APP-TA
-280.0
C-52
Concrete
PG100
SBS-SA
(Optional) SBS-SA, SBS-TA or
SBS-SA, APP-SA; SBS-TA or APP-TA '
,315.0
APP-TA
BP -AA (Optional if using asphalt
(Optionalf using asphalt
C-53
Concrete
PG100
applied Ply)
BBPI-IAA SSBS-AA, SBS TAeor
SBS-AA, SBS-TA, APP-TA
-622.5
APP-TA
Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report 139290.02.08-118 for FL1654-R10
Certificate of Authorization #9503 Revision 8: 12/06/2011
Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 17 of 30
TRINITi' I ERD
TABLE 4A: LIGHTWEIGHT CONCRETE DECKS — NEW CONSTRUCTION or REROOF (Tear -Off)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
Roof Deck
System
(See Note 1, Page 1)
Base Insulation Layer
Coverboard
Roof Cover
No.
$trUCt.
MDP (P
Deck
LWC
Type
Attach
Type
Attach
Base
Ply
Cap
SELF -ADHERING SYSTEMS WITH . BASE INSULATION AND OPTIONAL TOP INSULATION OF THE SAME TYPE:
LWC-1
Concrete
Min. 200 psi,
min 2-inch
Min. 1.5-inch, min. 2.0 pcf ASTM
OB500
(Optional) Additional
layers of base
OB500
SBS-SA
(Optoinal) One
or more SBS-
SBS-SA, APP-
SA, SBS-TA
-120.0
Elastizell
C578 expanded polystyrene
insulation
SA, SBS-TA or
or APP-TA
APP-TA
Concrete
Min. 200 psi,
p
min
Min. 1.5-inch ACFoam II, ENRGY
OB500
(Optional) Additional
layers of base
OB500
SBS-SA
(Optoinal) One
or more SBS-
SBS-SA, APP-
SA, SBS-TA
-225.0
izinch
Elastizell
Elastizell
3, ISO 95+ GL or H Shield
insulation
SA, SBS-TA or
or APP-TA
APP-TA
Min. 1.5-inch ACFoam II,
Min. 200 psi,
ACFoam III, ENRGY 3, ISO 95+
(Optional) Additional
(Optoinal) One
SBS-SA, APP-
LWC-3
Concrete
min. 2-inch
GL, H-Shield, H-Shield CG, Multi-
CR-20
layers of base
CR-20
SBS-SA
or more SBS-
SA, SBS-TA
-180.0
Elastizell
Max FA3 or min.'2.0 pcf ASTM
Insulation
SA, SBS-TA or
or APP TA
C578 expanded polystyrene
APP-TA
Min. 200, psi,
P
min. 2-inch
Min. 1.5-inch ACFoam II,
ACFoam III, ENRGY 3, ISO 95+
(Optional) Additional
(Optoinal) One
SBS-SA, APP-
LWC-4
Concrete
Celcore or
GL, H-Shield, H-Shield CG, Multi-
CR-20
layers of base
CR-20
SBS-SA
or more SBS-
SA, SBS-TA or
SA, SBS-TA
-222.5
Mearlcrete
Max FA3 or min. 2.0 pcf ASTM
insulation
APP-TA
or APP-TA
C578 expanded polystyrene
SELF -ADHERING SYSTEMS WITH BASE INSULATION AND COVERSOARD:
LWC-5
Concrete
Min. 200 psi,
min 2-inch
Min. 1.5-inch, min. 2.0 pcf ASTM
OB500
Min. 0.25-inch
SECUROCK Gypsum-
OB500
SBS-SA
(Optolnal) One
or more SBS-
SBS-SA, APP-
SA, SBS-TA
-120.0
Elastizell
C578 expanded polystyrene
Fiber Roof Board
SA, SBS-TA or
or APP-TA
APP-TA
LWC-6
Concrete
Min. 200 psi,
min 2-inch
Min. 1.5-inch ACFoam II, ENRGY
OB500
Min. 0.25-inch
SECUROCK Gypsum-
OB500
SBS-SA
(Opl) O i tonaOne
or more SBS-
SBS-SA, APP-
SA, SBS-TA
-225.0
Elastizell
3, ISO 95+ GL or H-Shield
Fiber Roof Board
SA, SBS-TA or
or APP-TA
APP-TA
Min. 1.5-inch ACFoam II,
Min. 200 psi,
ACFoam III, ENRGY 3, ISO 95+
Min. 0.25-inch
(Optoinal) One
SBS-SA, APP-
LWC-7
Concrete
min. 2-inch
GL, H-Shield, H-Shield CG, Multi-
CR-20
SECUROCK G ypsum-
CR-20
SBS-SA
or more SBS-
SA, SBS-TA
-180.0
Elastizell
Max FA3 or min.. 2.0 pcf ASTM
Fiber Roof Board
SA, SB
SASB
, SBS-TA or
or APP-TA
C578 expanded polystyrene
TA
Min. 200 psi,
min. 2-inch
Min. 1.5-inch ACFoam II,
ACFoam III, ENRGY 3, ISO 95+
Min. 0.25-inch
(Optoinal) One
SBS-SA, APP-
LWC-8
Concrete
Celcore
GL, H-Shield, H-Shield CG, Multi
CR-20
SECUROCK Gypsum-
CR 20
SBS-SA
or more SBS-
SA, SBS TA
-222.5
Mearlcrete
to
Max FA3 or min. 2.0 pcf ASTM
Fiber Roof Board
SA, SBS-TA or
APP-TA
or APP-TA
C578 expanded polystyrene
ASPHALT AND/OR TORCH APPLIED SYSTEMS: ,
Exterior Research and Design, LLC. d/b/a Trinity[ERD Evaluation Report P9290.02.08-R8 for FL1654-R10
Certificate of Authorization #9503 Revision 8: 12/06/2011
Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 18 of 30
`�E TRINITY I ERA
TABLE 4A: •LIGHTWEIGHT CONCRETE DECKS —NEW CONSTRUCTION or REROOF (Tear -Off)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
Roof Deck
-System
(See Note 1, Page 1)
Base Insulation Layer
Coverboard
Roof Cover
MOP (per
No.
Struct.
Deck
LWC
Type
Attach
Type
Attach
Base
Ply
Cap
Min. 200 psi,
Min. 1.5-inch ACFoam II, ENRGY
Min. 0.25-inch
BP -AA,
(Optional) One
or more BP -AA,
SBS-AA,
LWC-9
Concrete
min 2-inch
3, ISO 95+ GL or H-Shield
OB500
SECUROCK Gypsum-
OB500
SBS-AA,
SBS-AA, SBS-
SBS-TA, APP-
-225.0
Elastizell
Fiber Roof Board
APP-TA
TA or APP-TA
TA
Min. 1.5-inch ACFoam II,
(Optional)_One
Min. 200 psi,
ACFoam III, ENRGY 3, ISO 95+
Min. 0.25-inch
BP -AA,
or more BP -AA,
SBS-AA,
LWC-10
Concrete
min. 2-inch
GL, H-Shield, H-Shield CG, Multi-,
CR-20
SECUROCK Gypsum-
CR-20
SBS-AA,
SBS-AA, SBS-
SBS-TA, APP-
-180.0
Elastizell
Max FA3 or min. 2.0 pcf ASTM
Fiber Roof Board
APP-TA
TA or APP-TA
TA
C578 expanded polystyrene
Min. 200 psi,
Min. 1.5-inch ACFoam II,
(Optional) One
min. 2-inch
ACFoam III ENRGY 3 ISO 95+
Min. 0.25-inch
BP -AA,
or more BP -AA,
SBS-AA,
LWC-11
Concrete
Celcore or
GL, H-Shield, H-Shield CG, Multi-
CR-20
SECUROCK Gypsum-
CR-20
SBS-AA
'
SBS-AA, SBS
SBS-TA APP-
'
-222.5
Mearlcrete
Max FA3 min. pcf ASTM
Fiber Roof Board
APP-TA
TA or APP-TA
TA
C578 expanded polystyrene
TABLE 4B: LIGHTWEIGHT CONCRETE DECKS — NEW CONSTRUCTION or REROOF (Tear -Off)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
Roof Deck (See Note 1)
Anchor Sheet
Base Insulation
Top Insulation
Roof Cover
No.
Struct
LWC
Type
Fasts ner
Attach
T
Type
Attach
Type
Attach
Base
Ply
Cap
MOP
(per
Min. 1.5-inch
Min. ga.,
Min. 300
7-inch o.c. at
(Optional) Min.
Thermaroof
Composite,
(Optional if
Type B,
psi
GAFGLAS
OMG CR
4-Inch lap and
7-Inch o.c. iri
1.5 inch
ACFoam II H-
Polytherm
(Optional if
using AA
using AA
Base) One or
SBS-AA,
LWC-12
vented steel
Approved
#75
BSF
two, equally
Shield, Multi-
HA
Composite, or min.
HA
Ply) BP -AA,
more BP -AA
SBS-TA,
-45.0
at max. 5 ft
cellular
spaced center
Max FA3 or
0.5-inch Structodek
SBS-AA
SBS-AA, SB,
S-
APP-TA
spans
LWC
rows
Polytherm
HD Fiberboard or
TA or APP-TA
min. 0.75-inch
FescoBoard
Min. 22 ga.,
Min. 300.
7-inch o.c. at
4-inch lap and
Min. 1.5-inch
(Optional)
SBS-SA,
LWC-13
Type B,
vented steel
psi
A
Approved.
GAFGLAS
OMG CR
7-inch o.c. in
ACFoam II, H-
Shield, Multi-
HA
None
N/A
SBS-SA
One or more
APP-SA,
-45.0
at max. 5 ft
cellular
#75
BSF
two, equally
Max FA3
Max FA3 or
SBS-SA, SBS-
SBS-TA or
spans
LWC
spaced center
TA or APP-TA
APP-TA
rows
Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report P9290.02.08-R8 for FL1654-R10
Certificate of Authorization #9503 Revision 8: 12/06/2011
Prepared by: Robert Nieminen, PE-59166 Ap
pendix i, Page 19 of 30
fTkl.N-Il1(I END
TABLE 4C: LIGHTWEIGHT CONCRETE DECKS — NEW CONSTRUCTION or REROOF (Tear -Off)
SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
Roof Deck (See Note 1, Page 1)
Base Sheet (See Note A below)
Roof Cover
System
MD
No.
Structural Deck
Lightweight Concrete
Type
Fasteners
Attach
Ply
Cap
(psf)
(See Note A)
'GENERIC' CELLULAR LIGHTWEIGHT INSULATING CONCRETE:
Min. 300 psi, min. 2-Inch
thick cellular LWC. Note: To
Min. 22 ga., type B steel
qualify the LWIC under this
7-inch o.c. in a 3-inch lap
(Optional) One or
LWC-14
at max 5 ft spans or
assembly, an OMG CR BPF
shall achieve an average
83
OMG CR BPF
and 7-Inch o.c. in two,
equally spaced, staggered
more BP -AA, SBS-
SBS-AA, APP-TA
-45.0
structural concrete
withdrawal of 53 lbf when
rows In the field of the sheet
AA
tested per TAS 105 or
ANSIISPRI FX-1
CELCORE CELLULAR LIGHTWEIGHT INSULATING CONCRETE:
Min. 0.0179-inch
8-inch o.c. in a 3-inch lap
LWC-15
Tensilform S-75 or min.
0.0205-inch Tensilform 75
Min. 200 psi, min. 2-Inch
Bi, B2, B3 or 67
ES FM-90 or OMG CR
and 16-inch o:c. in two,
One or more BP-
SBS-AA
-37.5
at max. 5 It spans or
_ thick Celcore
BPF
equally spaced, staggered
AA, SBS-AA
structural concrete
rows in the field of the sheet
LWC-16
Min. 22 ga., type B steel
at max 5 ft spans or
Min. 200 psi, min. 2-inch
BI through B12
ES FM-90 or OMG CR
7-inch o.c. in a 3-inch lap
and 7-inch o.c. in two,
One or more BP-
SBS-AA
45.0
structural concrete
thick Celcore
BPF
equally spaced, staggered
AA, SBS-AA
rows in the field of the sheet
Min. 26 ga., type HF steel
Min. 225 psi, min. 2-Inch
B3, B2 B3, B4,
9-inch o.c. in a 3-inch lap
and 9-Inch o.c. in two,
One or more BP-
LWC-17
at max 5 ft spans or
thick Celcore MF
B7, B8, B10, B11
OMG CR BPF
equally spaced, staggered
AA, SBS-AA
SBS-AA
-45.0
structural concrete
or B12
rows in the field of the.sheet
Min. 22 ga., type,B steel
Min. psi, min. 2-Inch
Bl, B2, B3, 84,
7-Inch o.c. in a 3-inch lap
and h o.c. two,
One more BP
LWC-18
at max 6 It spans or
thick Celcore MF
Celcore
B7, B8, B10, B11
OMG CR BPF
equally t
equally spaced, staggered
sp
AA, SBS-AA
B
SBS-AA
-45.0
structural concrete
or B12
rows in the field of the sheet
Min. 22 ga., type B steel
Min. psi, min. 2-inch
B1, 82, B3, 64,
9-inch o.c. in a 3-inch lap
and inch is two,
One more BP
LWC-19
at max 6 it spans or
thick Celcore MF'
Cel
B7, B8, B30, B11
OMG CR BPF
equally spaced, staggered
l spao.cced,
AA, SBS AA
B
SBS-AA
-45.0
structural concrete
or B12
rows in the field of the sheet
Min. 26 ga., type HF steel
at max 5 ft spans or min.
Min. 200 psi, min. 2-Inch
9-inch o.c. in a 4-inch lap
One or more BP -
LWC-20
22 ga., type B steel at
thick Celcore or min. 225
B2 or B11
Simplex Turbo Tube-
and 12-inch o.c. in two,
AA, SBS-AA, SBS-
SBS-AA, SBS-TA,
-45.0
max 6 It spans or
psi, min. 2-inch thick
Lok
equally spaced, staggered
TA or APP-TA
or APP-TA
structural concrete
Celcore MF
rows in the field of the sheet
Min. 26 ga., type HF steel
at max 5 ft spans or min.
Min. 200 psi, min. 2-Inch
B2
9-inch o.c. in a 4-inch lap
One or more SBS-
LWC-21
22 ga., type B steel at
thick Celcore or min. 225
(with poly -film
Simplex Turbo Tube-
and inch o.c. in two ,
SA, SBS-TA or
SBS-SA, APP-SA,
-45.0
max 6 ft spans or
psi, min. 2-inch thick
top surface)
Lok
equally spaced, staggered
equally
APP-TA
SBS-TA or APP-TA
structural concrete
Celcore MF
rows in the field of the sheet
Exterior Research and Design, LLC. d/b/a TrinitylERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report P9290.02.08-R8 for FL1654-R10
Revision 8: 12/06/2011
Appendix 1, Page 20 of 30
Q�TANJTY[ERD
TABLE 4C: LIGHTWEIGHT CONCRETE DECKS — NEW CONSTRUCTION or REROOF (Tear -Off)
SYSTEM TYPE E. MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
Roof Deck (See Note 1, Page 1)
Roof
Base Sheet (See Note A below)
Roof CoVer
System
MOP
No.
Structural Deck
Lightweight Concrete
Type
Fasteners
Attach
Ply
Cap
(Psf)
(See Note A)
LWC-22
Min. 22 ga., type B steel
at max 5 ft spans or
Min. 225 psi, min. 2-Inch
Bl or B2
ES Twin Loc-Nail
9-inch o.c. in a 4-Inch lap
and 18-Inch o.c. in two,
One or more BP -
ASBS-
AA, SBS-A,
SBS-AA, SBS-TA,
45.0
structural concrete
thick Celcore MF
equally spaced, staggered
TA or APP-
or APP-TA
rows in the field of the sheet
Min. 22 ga., type B steel
Min. 225 psi, min. 2-Inch
B2
9-inch o.c. in a 4-Inch lap
and 18-inch o.c, in two,
One or more SBS-
SBS-SA, APP-SA,
LWC-23
at max 5 ft spans or
thick Celcore MF
(with poly -film
ES Twin Loc-Nail
equally spaced, staggered
SA, SBS-TA or
SBS-TA or APP-TA
-45.0
structural concrete
top surface)
rows in the field of the sheet
APP-TA
8-inch o.c. in a 4-inch lap
LWC-24
Min. 22 ga., type B steel
at max 5 ft spans or
Min. 300 psi, min. 2-inch
B2
ES FM-90
and 8-inch o.c. in three
BP -AA, SBS-AA,
SBS-AA, SBS-TA,
60.0
thick Celcore MF
equally spaced, staggered
SBS-TA or APP-TA
or APP-TA
structural concrete
center rows
Min. 22 ga., type B steel
Min. 300 psi, min. 2-inch
B2
8-incin a 4-inch la c h o.. p
and 8-Inch o.c. in three
One or more SBS-
SBS-SA, APP-SA,
LWC-25
at max 5 ft spans or
thick Celcore MF
( with poly -film
ES FM-90
equally spaced, staggered
SA, SBS-TA or
APP-TA
SBS-TA or APP-TA
-60.0
structural concrete
top surface)
center rows
LWC-26
Min. 22 ga., type B steel
at max 5 ft spans or
Min. 300 psi, min. 2-inch
Bl through B12
ES FM-90 or OMG CR
7-inch o.c. in a 3-inch lap
and 7-inch o.c. In two,
One or more BP-
S135-AA
-75.0
structural concrete
thick Celcore
13PF
equally spaced, staggered
AA, SBS-AA
rows in the field of the sheet
Min. 22 ga., type B steel
Min: 300 psi; min. 2-inch
10-inch o.c. in a 4-inch lap
and 10-inch o.c. in three
(Optional) BP -AA,
SBS-AA, SBS-TA,
LWC-27
at max 5 ft spans or -
thick Celcore MF
Elastobase Poly
ES FM-260
equally spaced, staggered
SBS AA, SBS-TA
APP-TA
-90.0
structural concrete
center rows
or APP-TA
ELASTIZELL CELLULAR LIGHTWEIGHT INSULATING CONCRETE:
Min. 0.0179-inch
Tensilform S-75 or min.
7.5-inch o.c. in a 3-Inch lap
One or more BP-
LWC-28
0.0205-inch Tensilform 75
Min. 200 psi, min. 2-inch
Bl through B12
ES. FM-90 or OMG CR
and 7.5-inch o.c. in two,
AA, SBS-AA, SBS-
SBS-AASBS-TA
, ,
-30.0
at max. 5 ft spans or
thick Elastizell Range IIBPF
equally spaced, staggered
TA, or APP-TA
or APP-TA
structural concrete
rows in the field of the sheet
Min. 0.0179-inch
Tensilform S-75 or min.
B2
7.5-inch o.c. in a 3-Inch lap
One or more SBS-
LWC-29 .
0.0205-inch Tensilform 75
Min. 200 psi, min_ 2-inch
thick Elastizell Range II
(with poly -film
ES FM-90 or OMG CR
BPF
and 7.5-inch o.c. in two,
equally spaced, staggered
SA, SBS-TA or
SBS-SA, APP-SA,
SBS-TA or APP-TA
-30.0
at max. 5 ft spans or
top surface)
rows in the field of the sheet
APP-TA
structural concrete
LWC-30
Min. 22 ga., type B steel
at max 5 ft spans or
Min. 200 psi, min. 2-inch
gl through 612
ES FM-90 or OMG CR
in a 3-inch lap 7-inch o.c.
and inch in two,
One or more BP-
AA, SBS-AA, SBS-
SBS-AA, SBS-TA,
-45.0
structural concrete
thick Elastizell Range II
BPF
equally spaced, staggered
TA, or APP-TA
or APP-TA
rows in the field of the sheet
Min. 22 ga., type B steel
Min. 200 psi, min. 2-Inch
B2
ES FM-90 or OMG CR
7-inch o.c. in a 3-inch lap
and 7-inch o.c. in two,
One or more SBS-
SBS-SA, APP-SA,
LWC-31
at max 5 ft spans or
thick Elastizell Range II
(with poly -film
BPF
equally spaced, staggered
SA, SBS-TA or
SBS-TA or APP-TA
-45.0
structural concrete
top surface)
rows in the field of the sheet
APP-TA
Exterior Research and Design, LLC. d/b/a Trinity IERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report P9290.02.08-R8 for FL1654-R10
Revision 8: 12/06/2011
Appendix 1, Page 21 of 30
QTRiNITYIE�tD
TABLE 4C: LIGHTWEIGHT CONCRETE DECKS — NEW CONSTRUCTION or REROOF (Tear -Off)
SYSTEM TYPE E. MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
Roof Deck (See Note 1, Page 1)
Base Sheet (See Note A below)
Roof Cover
System
MOP
No.
Structural Deck
Lightweight Concrete
Type
Fasteners
Attach
Ply
Cap
(Psf)
(See Note A)
Min. 22 ga., type B steel
Min. 200 psi, min. 2-inch
Simplex Turbo Tube-
9-inch o.c. in a 4-Inch lap
and 12-inch o.c. in two,
One or more BP-
AA, SBS-AA, SBS-
SBS-AA, SBS-TA,
SBS-SA, APP-TA
-45.0*
LWC-32
at max 5 ft spans or
thick Elastizell Range II
B2 or B11
Lok
equally spaced, staggered
TA, SBS-SA, or
APP-SA
structural i concrete
rows in the field of the sheet
APP-TA
or
Min. 350 psi, min. 2-inch
Min. 22 ga., type B steel
thick Elastizell with Zell-
6-inch o.c. in a 4-inch lap
SBS-AA, SBS-TA,
LWC-33
at max 5 ft spans or
Crete Fibers, supple-
B2
ES Twin Loc-Nails
and 6-inch o.c. in three,
One or more BP-
SBS-SA, APP-TA
-60.0
structural concrete
mentally attached with
(min. 1.8-inch)
equally spaced, staggered
AA or SBS-AA
or APP-SA
Roofgrip #21 and 3-inch
rows In the field of the. sheet
plates at 1 per 8 ft2
Min. 350 psi, min. 2-inch
Min. 22 ga., type B steel
thick Elastizell with Zell-
Crete Fibers, supple-
B2
ES Twin Loc-Nails
6-inch o.c. in a 4-Inch lap
and 6-inch o.c. in three,
SBS-SA, SBS-TA
SBS-SA, APP-SA,
-60.0
LWC 34
at max 5 It spans or
p
mentally attached with
(with poly -film
(min. 1.8-inch)
equally spaced, staggered
or APP-TA
SBS-TA or APP-TA
structural concrete
Roofgrip #21 and 3-inch
top surface)
rows In the field of the sheet
plates at 1 per 8 ft2
MEARLCRETE CELLULAR LIGHTWEIGHT INSULATING CONCRETE:
7.5-inch o.c. in a 3-inch lap
LWC-35
Min. 24 ga., type B steel
at max 5 ft spans or
Min. 200 psi, min. 2-inch
Bi through B12
ES FM-90 or OMG CR
and 10-inch o.c. in two,
One or more BP-
SBS-AA
-30.0
thick Mearlcrete
BPF
equally spaced, staggered
AA, SBS-AA
structural concrete
rows in the field of the sheet
LWC-36
Min. 22 ga., type B steel
at max 5 ft spans or
Min. 300 psi, min. 2-inch
Bl, B2 or B12
ES FM-90 or OMG CR
7-Inch o.c. in a 4-inch lap
and 7-inch o.c. in two,
One or more BP -
�I SBS-AA, SBS-
SBS-AA, SBS-TA,
-45.0
structural concrete
thick Mearicrete
.
BPF
equally spaced, staggered
TA, or APP-TA
or APP-TA
rows in the field of the sheet
Min. 22 ga., type B steel
Min. 300 psi, min. 2-inch
62
ES FM-90 or OMG CR
7-Inch o.c. in a 4-inch lap
and 7-inch o.c. in two,
One or more SBS-
SA, SBS TA or
SBS-SA, APP-SA,
-45.0
LWC-37
at max 5 ft spans or
thick Mearicrete
(with poly -film
BPF
equally spaced, staggered
APP TA
SBS-TA or APP-TA
structural concrete
top surface)
rows in the field of the sheet
LWC-38
Min. 22 ga., type B steel
at max 5 ft spans or
Min. 300 psi, min. 2-inch
B3, B2, B3, 84,
Simplex Base-Lok
9-inch o.c. in a 4-inch lap
and 9-inch o.c. in two,
One or more BP -
AA, SBS-AA, SBS-
SBS-AA, SBS-TA,
-45.0
structural concrete
thick Mearicrete
B7, B8 or Bll
equally spaced, staggered
TA, or APP TA
or APP-TA
rows in the field of the sheet
Min. 22 ga., type B steel
Min. 300 psi, min. 2-inch
B2
9-inch o.c. in a 4-inch lap
and inch is two,
One or more 58S-
SBS-SA, P
LWC-39
at max 5 ft spans or
thick Mearicrete
(with poly -film
Simplex Base-Lok
ll spaced,
equally spaced, staggered
SA, SBS-TA or
r P-T
SBS-TA or APP TA
-45.0
structural concrete
top surface)
rows in the field of the sheet
APP-TA
Min. 22 ga.,'type B steel
9-inch o.c. in a 4-inch lap
One or more BP -
SBS-AA, SBS-TA,
LWC-40
at max 5 ft spans or
Min. 300 psi, min. 2-inch
B2 or Bii
Simplex Turbo Tube-
and 12-inch o.c. in two,
AA, SBS-AA, SBS-
SBS-SA, APP-TA
-45.0
structural concrete
thick Mearicrete
Lok
equally spaced, staggered
TA, SBS-SA, or
or APP-SA
rows in the field of the sheet
APP-TA
Min. 22 ga., type B steel
Min. 300 psi, min. 2-inch
B1, B2, B3, B7 or
ES FM-90 or OMG CR
in a 4-inch lap 7-inch o.c.
and 7-inch o.c. in two,
One or more BP -
SBS-AA, SBS-TA,
LWC-41
at max 5 ft spans or
thick Mearicrete
B11
BPF
equally spaced, staggered
AA, , SBS-
or APP-TA
52.5
structural concrete
rows in the field of the sheet
TA, or PP -
or APP-TA
Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report P9290_.02.08-R8 for FL1654-RlO
Certificate of Authorization #9503 Revision 8: 12/06/2011
Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 22 of 30
TRINITY jeRD
TABLE 4C: LIGHTWEIGHT CONCRETE DECKS — NEW CONSTRUCTION or REROOF (Tear -Off)
SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
Roof Deck (See Note 1, Page 1)
Base Sheet (See Note A below)
Roof Cover
System
MOP
No.
Structural Deck
Lightweight Concrete
Type
Fasteners
Attach
Ply
Cap
(Psf)
(See Note A)
Min. 22 ga., type B steel
Min. 300 psi, min. 2-Inch
B2
ES FM-90 or OMG CR
7-inch o.c. in a 4-inch lap
and 7 inch o.c. in two,
One or more SBS
SBS-SA, APP-SA,
LWC-42
at max 5 ft spans or
thick Mearicrete
poly -film
BPF
equally spaced, staggered
SA, SBS-TA or
SBS-TA or APP-TA
-52.5
structural concrete
twits
top surface)
rows in the field of the sheet
APP-TA
Min. 22 ga., type B steel
Min. 300 psi, min. 2-inch
in a 4-inch lap 9-inch o.c.
and 12-inch o.c. in two,
One or more BP-
SBS-AA, SBS-TA,
LWC-43
at max 5 ft spans or
thick Mearicrete
B3, B2, B3 or B4
Simplex Base-Lok
equally spaced, staggered
AA SBS-AA, SBS-
or APP-TA
-52.5
structural. concrete
rows in the field of the sheet
TA, or APP-TA
Min. 22 ga., type B steel
Min. 300 psi, min. 2-inch
82
9 Inch o.c. in a 4-inch lap
and 12-inch o.c. in two,
One or more SBS-
SBS-SA, APP-SA,
LWC-44
at max 5 ft spans or
thick Mearicrete
poly -film
Simplex Base-Lok
equally spaced, staggered
SA, SBS-TA or
SBS-TA or APP-TA
-52.5
structural concrete
twits
top surface)
rows in the field of the sheet
APP-TA
Base Sheets options are coded as follows:
> 61: Polyglass G2 Base;
> 132: Elastobase or Elastobase Poly;
> 63: GAFGLAS #75;
> 84: Stratavent Eliminator Venting Base Sheet (Nailable);
➢ B5: GAFGLAS Ply 4;
> B6: GAFGLAS FlexPly 6;
> B7: JM Perma Ply No. 28;
➢ B8: JM Vensulation, -
➢ 139: JM GlasPly IV;
> B10: JM GlasPly Premier;
> B11: Tamko Glass -Base;
> 612: Tamko Vapor -Chan .
Exterior Research and Design, LLC. d/b/a TrinityjERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report P9290.02.08-R8 for FL1654-RIO
Revision 8: 12/06/2011
Appendix 1, Page 23 of 30
�i I KII`+1111i18RD
TABLE SA: CEMEMTITIOUS WOOD FIBER DECKS — NEW CONSTRUCTION or REROOF (Tear -Off)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
Base Insulation Layer
Top Insulation Layer
Roof Cover
Deck
MDP (psf)
Type
Attach
Type
Attach
Base
Ply
Cap
No.
Min. 0.25-inch
Min. 1.5-inch
DensDeck, DensDeck
(Optional) One or
CWF-1
Min. 2.5-inch Tectum
ACFoam II, ISO
95+GL, H-Shield,
D-IS or OB500
Prime, SECUROCK
Gypsum -Fiber Roof
D-IS or OB500
BP -AA, SBS-
more BP -AA, SBS-
SBS-AA, SBS-
-45.0
Plank or Tectum LS Plank
Polytherm,
Board or min. 0.5-
AA
AA, SBS-TA or APP-
TA, APO -TA
ENRGY-3
inch Structodek HD
TA
Fiberboard
Min. 1.5-inch
Min, 0.25-inch
Min. 2.5-inch Tectum
ACFoam II, ISO
DensDeck, DensDeck
SBS-TA,
(Optional) One or
SBS-TA, SBS-
CWF-2
Plank or Tectum LS Plank
95+GL, H-Shield,
D-IS or OB500
Prime, SECUROCK
D-IS or OB500
SBS-SA or
more SBS-TA, SBS-
SA, APP-TA,
-45.0
Polytherm,
Gypsum -Fiber Roof
APP-TA
SA or APP-TA
APP-SA
ENRGY-3
Board
Min. 0.25-inch
Min. 1.5-inch
DensDeck, DensDeck
(Optional) One or
CWF-3
Min. 2.5-inch Tectum
ACFoam II, ISO
95+GL, H-Shield,
CR-20
Prime, SECUROCK
Gypsum -Fiber Roof
CR-20
BP -AA SBS-
more BP -AA, SBS-
SBS-AA, SBS-
-52.5
Plank or Tectum LS Plank
Polytherm,
Board or min. 0.5-
AA
AA, SBS-TA or APP-
TA, APP-TA
ENRGY-3
inch Structodek HD
TA
Fiberboard
Min. 1.5-inch
Min. 0.25-inch
Min. 2.5-inch Tectum
ACFoam II, ISO
DensDeck, DensDeck
SBS-TA,
(Optional) One or
SBS-TA, SBS-
CWF 4
Plank or Tectum LS Plank
95+GL, H-Shield,
CR-20
Prime, SECUROCK
CR-20
SBS-SA or
more SBS-TA, SBS-
SA, APP-TA,
-52.5
Polytherm,
Gypsum -Fiber Roof
APP-TA
SA or APP-TA
APP-SA
ENRGY-3
Board
Exterior Research and Design, LLC. d/b/a TrinitylERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report P9290.02.08-R8 for FL1654-RIO
Revision 8: 12/06/2011
Appendix 1, Page 24 of 30
(.. I k -.11. � I E
RD
TABLE 5B: CEMENTITIOUS WOOD FIBER DECKS — NEW CONSTRUCTION or REROOF (Tear -Off)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
Anchor Sheet
Base Insulation
Top Insulation
Roof Cover
MDP
No.
Roof Deck
Type
Fastener
Attach
Type
Attach
Type
Attach
Base
Ply
Cap
(Psf)
9-inch o.c. in
Min. 1.5-inch
Min. 0.25-Inch
DensDeck, DensDeck
(Optional)
Min. 2.5-inch
Elastobase,
ES
4-Inch lap and
12-Inch o.c. in
ACFoam II,
ACFoam III,
Prime, SECUROCK
One or
SBS-AA,
CWF-5
Tectum Plank or
Elastobase
Poly, Polyglass
Inuldek
two, equally
IS095+GL, H-
HA
Gypsum -Fiber Roof
Board, Min. 0.75-inch
HA
BP -AA,
SBS-AA
more BP-
AA, SBS-
SBS-TA,
-30.0*
Tectum LS Plank
G2 Base
Loc-Nail
spaced,
Shield, ENRGY 3,
FescoBoard or min.
AA, SBS-TA
APP-TA
staggered
0.5-inch Structodek
or APP-TA
center rows
Multi-PolythMax FA
Multi -Max FA3,
HD Fiberboard
9-inch o.c. in
Min. 1.5-inch
Elastobase,
4-inch lap and
ACFoam II,
Min. 0.25-inch
(Optional)
SBS-TA,
Min. 2.5-inch
Elastobase
ES
12-Inch o.c. in
ACFoam III,
DensDeck, DensDeck
SBS-TA,
One or
SBS-SA,
CWF-6
Tectum Plank or
Poly, Polyglass
Inuldek
two equally
IS095+GL, H-
HA
Prime SECUROCK
HA
SBS-SA or
more SBS-
APP-TA,
-30.0*
Tectum LS Plank
G2 Base
Loc-Nail
spaced,
Shield, ENRGY 3,
Gypsum -Fiber Roof
APP-TA
TA, SBS-SA
APP-SA
staggered
Polytherm or
Board
or APP-TA
center rows
Multi -Max FA3,
9-inch o.c. in
Min. 1.5-inch
Min. 0.25-inch
DensDeck, DensDeck
(Optional)
Min. 2.5-Inch
Elastobase,
Simplex
Base-Lok
4-Inch lap and
18-inch o.c. in
ACFoam II,
ACFoam III,
Prime SECUROCK
'
One or
SBS-AA,
CWF-7
Tectum Plank or
Elastobase
Poly, Polyglass
or ES
two, equally
IS095+GL, H-
HA
Gypsum -Fiber Roof
Board, Min. 0.75-inch
HA
BP -AA,
SBS-AA
more BP-
AA, SBS-
SBS-TA,
-45.0*
Tectum LS Plank
G2 Base
Twin Loc-
spaced,
Shield, ENRGY 3,
FescoBoard or min.
AA, SBS-TA
APP-TA
Nail
staggered
Polytherm or
U.5-inch Structodek
or APP-TA
center rows
Multi -Max FA3,
HD Fiberboard
9-inch o.c. in
Min. 1.5-inch
Elastobase,
Simplex
4-inch lap and
ACFoam II,
Min. 0.25-Inch
(Optional)
SBS-TA,
Min. 2.5-inch
Elastobase
Base-Lok
18-inch o.c. in
ACFoam III,
DensDeck, DensDeck
SBS-TA,
One or
SBS SA,
CWF 8
Tectum Plank or
Poly, Polyglass
or ES
two, equally
IS095+GL, H-
HA
Prime, SECUROCK
HA
SBS SA or
more SBS-
APP-TA,
45.0 *
Tectum LS Plank
G2 Base
Twin Loc-
spaced,
Shield, ENRGY 3,
Gypsum -Fiber Roof
APP-TA
TA, SBS-SA
APP-SA
Nail
staggered
Polytherm or
Board
or APP-TA
center rows
Multi -Max FA3,
TABLE SC: CEMENTITIOUS WOOD FIBER DECKS — NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER
SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
Base Insulation Layer
Top Insulation Layer
Roof Cover
MOP
No.
Roof Deck
Type
Fasteners
Attach
Type
Attach
Base
Ply
Cap
(psf)
OMG N.T.B. Plate
'0.5-inch
(Optional if
(Optional if using
Min. 2.5-inch Tectum
Min. 2-inch H-
with N.T.B. Magnum
Min.
using, AA Ply)
AA Base) One or
SBS-AA,
CWF-9
Plank or Tectum LS
Shield or
or TruFast TL 3 in.
1 per 4 fe
Structodek HD
HA
SBS _
more BP -AA, SBS-
SBS-TA,
-45.0
Plank
Polytherm
Plate with TL
Fiberboard
AA
AA,
AA, SBS-TA or
APP-TA
Fastener
APP-TA
Exterior Research and Design, LLC. d/b/a TrinitylERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen; PE-59166
Evaluation Report P9290.02.08-R8 for FL1654-R10
Revision 8: 12/06/2011
Appendix 1, Page 25 of 30
* i ITY ERD
_.. I
TABLE SD: CEMENTITIOUS WOOD FIBER DECKS — NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER
SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
Roof Deck
Base Insulation
Top Insulation Layer
Roof Cover
MDP (per
Type
Fasteners
Attach
Base �
Ply
Cap
No.
Layer
(Optional) One or
Min. 0.25-inch DensDeck,
(Optional if using
CWF-SO
Min. 2.5-inch
Tectum Plank or
more layers, any
DensDeck Prime or SECUROCK
Gypsum -Fiber Roof Board or
ES Twin Lac -Nails (min.
1 per 2 ftZ
(Optional if
using AA Ply)
AA Base) One or
more BP -AA, SBS-
SBS-AA,
SBS-TA,
-45.0 *
Tectum LS Plank
combination, loose
min. 0.5-inch Structodek HD
1-inch embedment)
BP -AA, SBS-AA
AA, SBS-TA or
APP-TA
laid
Fiberboard
APP-TA
TABLE 5E: CEMENTITIOUS WOOD FIBER DECKS — NEW CONSTRUCTION or REROOF (Tear -Off)
SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED'BASE SHEET, BONDED ROOF COVER
System
Base Sheet
Roof Cover
MDP
No.
Roof Deck
Base
Fasteners
Attach
Ply
Cap
(psf)
CWF-11
Min. 2.5-inch
Tectum Plank or
Elastobase, Elastobase Poly, Polyglass G2
ES Inuldek Loc Nail
9-inch o.c. in 4-inch lap and 12- ..
inch o.c. in two, equally spaced,
(Optional) One or
more BP -AA,
SBS-AA, SBS-
-30.0*
Tectum LS Plank
Base
staggered center rows
SBS-AA, SBS-TA
or APP-TA
TA, APP-TA
CWF-12
Min. 2.5-Inch
Tectum Plank or
Elastobase, Elastobase Poly, Polyglass G2
Simplex Base-Lok or ES
9-inch o.c. in 4-inch lap and 18- ..
inch o.c. in two, equally spaced,
(Optional) One or
more BP -AA,
SBS-AA, SBS-
-45.0
Tectum LS Plank
Base
Twin Loc-Nails
staggered center rows
SBS-AA, SBS-TA
TA, APP-TA
or APP-TA
Exterior Research and"Design, LLC. d/b/a TrinitylERD Evaluation Report P9290.02.08-118 for FL1654-R30
Certificate of Authorization *9503 Revision 8: 12/06/2011
Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 26 of 30
�RINIT1f�ERD
TABLE 6A: GYPSUM DECKS — REROOF (Tear -Off)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
Base Insulation Layer
Top Insulation Layer
Roof Cover
MDP (psf)
Type
Attach
Type
Attach
Base
Ply
Cap
No.
Deck
Min. 1.5-inch
(Optional) additional
Existing, sound poured
ACFoam II, ENRGY 3
or H-Shield or min.
layers(s) of base
insulation and/or
(Optional) One or
SBS-SA, APP-
G-1
gypsum or gypsum plank
2.0 pcf, ASTM C578
OB500
min. 0.25-inch
0B500
SBS SA
more SBS-SA, SBS-
SA,
-112.5
deck
expanded
SECUROCK Gypsum-
TA or APP TA.
or APP-TA
PP TA
polystyrene
Fiber Roof Board
(Optional) additional
Existing, sound poured
Min. 1.5-inch
ACFoam II, ENRGY
layers(s) of base
insulation and/or
(Optional) One
SBS-SA, APP-
G 2
gypsum or gypsum plank
3, H-Shield or Multi-
M-OSFA
min. 0.25-inch
M-OSFA
SBS-SA
S-
more SBS-SA, SBS-
SA, SBS-TPP-TA
-202.5
deck
Max FA3
SECUROCK Gypsum-
TA or APP TA
or APP-TA
Fiber Roof Board
(Optional) additional
Existing, sound poured
Min. 1.5-inch, min.
layers of base
insulation and/or
(Optional) One or
SBS-SA, APP-
G-3
gypsum or gypsum plank
2.0 pcf EPS insulation
CR-20
min. 0.25-inch
CR-20
SBS-SA
more SBS-SA, SBS-
SA, SBS-TA
-240.0
deck
board
SECUROCK Gypsum -
TA or APP-TA
or APP-TA
Fiber Roof Board
Min. 0.25-inch
(Optional if
(Optional if using AA
Existing, sound poured
DensDeck, DensDeck
using AA
Base) One or more
SBS-AA, SBS-
G-4
gypsum or gypsum plank
Prime or SECUROCK
CR-20
None
N/A
Ply) BP -AA,
BP -AA, ,
TA, APP-TA
-245.0
deck
Gypsum -Fiber Roof
SBS AA
or APP
SBS-TA or APP-TA
Board
Min. 1.5-inch
(Optional) additional
Existing, sound poured
ACFoam II, ACFoa
layers(s) of basem
insulation and/or
(Optional) One or
SBS-SA, APP-
G-5
gypsum or gypsum plank
III, ENRGY 3, H-
CR-20
min. 0.25-inch
CR-20
SBS-SA
more SBS-SA, SBS-
SA, SBS-TA
-257.5
deck
Shield, H-Shield CG
SECUROCK Gypsum -
TA or APP-TA
or APP-TA
or Multi Max FA3
Fiber Roof Board
Exterior Research and Design, LLC. d/b/a TrinityjERD Evaluation Report P9290.02.08-R8 for FL1654-R10
Certificate of Authorization #9503 Revision 8: 12/06/2011
Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 27 of 30
TRINI7Y��RD
TABLE 6113: GYPSUM DECKS — REROOF (Tear -Off)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
Anchor Sheet
Base Insulation
Top Insulation
Roof Cover
System
No.
Roof Deck
MOP
(psf)
Type
Fastsener
Attach
�
Type
Attach
Type
Attach
Base
Ply
Cap
9-inch o.c. in
Min. 1.5-inch
Min. 0.25-inch
DensDeck, DensDeck
(Optional)
Existing, sound
Elastobase,
4-inch lap and
18-Inch o.c. in
ACFoam II,
ACFoam III,
Prime, SECUROCK
One or
SBS-AA,
G-6
poured gypsum or
Elastobase
ES FM-45
two, equally
IS095+GL, H-
HA
Gypsum -Fiber Roof
HA
BP -AA,
more BP-
SBS-TA,
-30.0*
gypsum plank
Poly, Polyglass
or.FM-60
spaced,
Shield, ENRGY 3,
Board Min. 0.75-inch
'
SBS-AA
AA, SBS-
APP-TA
deck
G2 Base
staggered
Polytherm or
FescoBoard or min.
AA,
center rows
Multi -Max FA3,
inch Structodek
P-TA
or APP-TA
HD Fiberboard
HD
9-Inch o.c. in
Min. 1.5-inch
Min. 0.25-Inch
DensDeck, DensDeck
(Optional)'
Existing, sound
Elastobase,
ES FM-75
4-inch lap and
18-inch o.c. in
ACFoam II,
ACFoam III,
Prime SECUROCK
One or
SBS-AA,
G-7
poured gypsum or
Elastobase
or FM-90
two, equally
IS0 H-
HA
Gypsum Fiber Roof
HA'
BP -AA,
more BP-
SBS-TA,
-45.0*
gypsum plank
Poly, Polyglass
or Twin
spaced
Shield, ENRGY 3,
Board, Min. 0.75-inch
SBS-AA
AA, SBS-
APP-TA
deck
G2 Base
Loc-Nails
,
staggered
,
Polytherm or
FescoBoard or min,
AA, SBS-TA
center rows
Multi -Max FA3,
0.5-Inch Structodek
or APP-TA
HD Fiberboard
TABLE 6C: GYPSUM DECKS — REROOF (Tear -Off) or RECOVER
SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
Roof Deck
Base Insulation
Top Insulation Layer
Roof Cover
MOP (psf)
Type
Fasteners
Attach
Base
Ply
Cap
No.
Layer
Existing sound
(Optional) One or
Min. 0.25-inch DensDeck,
(Optional if using
G-8
poured gypsum
more layers, any
DensDeck Prime or SECUROCK
Gypsum -Fiber Roof Board or
ES Twin Loc-Nails (min.
1 per 2 ft'
(Optional if
using AA Ply)
AA Base) One or
more BP -AA, SBS-
SBS-AA,
SBS-TA,
-45.0*
or gypsum plank
combination, loose
min. '0.5-inch Structodek HD
1-inch embedment)
BP -AAA SBS-AA
AA, SBS-TA or
APP-TA
deck
laid
Fiberboard
I
APP-TA
TABLE 6D: GYPSUM DECKS — REROOF (Tear -Off)
SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
Base Sheet
Roof Cover
No.
Roof Deck
Base
Fasteners
Attach
Ply
Cap
MOP (psf)
Existing sound
Elastobase, Elastobase Poly, Polyglass G2
9-Inch o.c. in 4-inch lap and 18-
(Optional) One or
more BP -AA,
SBS-AA SBS-
G-9
poured gypsum or
Base
ES FM-45 or FM-60
inch o.c. in two, equally spaced,
SBS-AA, SBS-TA
TA, APP-TA
-30.0*
gypsum plank deck
staggered center rows
or APP-TA
G-10
Existing sound
poured gypsum or
Elastobase, Elastobase Poly, Polyglass G2
ES FM-75 or FM-90 or
9inch o.c. in 4 inch lap and 18-
,
inch o.c. in two, equally spaced,
(Optional) One or
more BP -AA,
SBS-AA, SBS-
-45.0
gypsum plank deck
Base
Twin Loc-Nails
staggered center rows
SBS-AA, SBS-TA
TA, APP-TA
or APP-TA
Exterior Research and Design, LLC. d/b/a TrinitylERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report P9290.02.08-R8 for FL1654-R10
Revision 8: 12/06/2011
Appendix 1, Page 28 of 30
(Z)�
RINIIY [ER.
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
Base Insulation Layer
Top Insulation Layer
Roof Cover
No.
Substrate
MDP (psf)
Type
Attach
Type
Attach
Base
Ply
Cap
(Optional) additional
Existing
layers(s) of base
(Optional) One or
SBS-SA, APP-
R-1
asphaltic
Min. 1.5-Inch Multi -Max FA3
D-IS
insulation and/or min.
D-IS
SBS-SA
more SBS-SA,
SA, SBS-TA or
-67.5
roof
0.25-inch SECUROCK
SBS-TA or APP-TA
APP-TA
Gypsum -Fiber Roof Board
(Optional) additional
Existing
Min. 1.5-inch ACFoam II or
layers(s) of base
(Optional) One or
SBS-SA, APP-
R-2
asphaltic
ENRGY 3 or min. 2.0 pcf EPS
D-IS
insulation and/or min.
D-IS
SBS-SA
more SBS-SA,
SA, SBS-TA or
-90.0
roof
insulation board
0.25-inch SECUROCK
SBS-TA or APP-TA
APP-TA
Gypsum -Fiber Roof Board
(Optional) additional
Existing
Min. 1.5-inch, min. 2.0 pcf EPS
layers of base Insulation
(Optional) One or
SBS-SA, APP-
R-3
asphaltic
insulation board
OB500
and/or min. 0.25-inch
OB500
SBS-SA
more SBS-SA,
SA, SBS-TA or
-120.0
roof
SECUROCK Gypsum -Fiber
SBS-TA or APP-TA
APP-TA
Roof Board
(Optional) additional
Existing
-Min. 1.5-Inch ACFoam II,
layers(s) of base
'and/or
(Optional) One or
SBS-SA, APP-
R-4
asphaltic
ENRGY 3 or H Shield
OB500
1 nsu lation min.
06500
SBS-SA
more SBS-SA,
SA, SBS-TA or
-127.5
roof
0.25-inch SECUROCK
SBS-TA or APP-TA
APP-TA
Gypsum -Fiber Roof Board
(Optional) additional
Existing
Min. 1.5-inch ACFoam II,
layers(s) of base
(Optional) One or
SBS-SA, APP-
R-5
asphaltic
ENRGY 3, H-Shield or Multi -Max
M-OSFA
insulation and/or min.
M-OSFA
SBS-SA
more SBS-SA,
SA, SBS-TA or
-157.5
roof
FA3
0.25-Inch SECUROCK
SBS-TA or APP-TA
APP-TA
Gypsum -Fiber Roof Board
Min. 2-inch ACFoam IV, min.
1.5-Inch Ultra -Max or Multi -Max
(Optional) additional
Existing
FA-3, min. 1.3-inch ACFoam III
layers(s) of base
(Optional) One or
SBS-SA, APP-
R-6
asphaltic
or min. 1.0-inch'ISO 95+GL, H-
CR-20
Insulation and/or min.
CR-20
SBS-SA
more SBS-SA,
SA, SBS-TA or
-240.0
roof
Shield, H-Shield CG or ENRGY 3
0.25-inch SECUROCK
SBS-TA or APP-TA
APP-TA
or min. 2.0 pcf ASTM C578
Gypsum -Fiber Roof Board
expanded polystyrene
Min. 2-inch ACFoam II, ENRGY-
(Optional) additional
Existing
3 or H-Shield or min. 2.0 pcf
layers(s) of base
(Optional) One or
SBS-SA, APP-
R-7
asphaltic
ASTM C578 expanded
CR-20
insulation and/or min.
CR-20
SBS-SA
more SBS-SA,
SA, SBS-TA or
-247.5
roof
polystyrene
0.25-inch SECUROCK
SBS-TA or APP-TA
APP-TA
Gypsum -Fiber Roof Board
Existing
-
Min. 0.25-inch DensDeck,
BP -AA, SBS-
(Optional) One or
R-8
asphaltic
Min. 1.5-inch Multi -Max FA3
D-IS
DensDeck Prime or
D-IS
AA, SBS-TA,
more BP -AA, SBS-
SBS-AA, SBS-
-67.5
roof
SECUROCK Gypsum -Fiber
SBS-SA,
AA, SBS-TAor
TA, orAPP-TA
Roof Board
APP-TA
APP-TA
Existing
Min. 1.5-inch ACFoam II or
Min. 0.25-inch DensDeck,
BP -AA, SBS-
(Optional) One or
R-9
asphaltic
ENRGY 3 or min. 2.0 pcf EPS
D IS
DensDeck Prime or
tS
AA, SBS-TA,
more BP -AA, SBS-
SBS-AA, SBS-
-90.0
roof
insulation board
SECUROCK Gypsum -Fiber
SBS-SA,
AA, SBS-TAor
TA, or APP-TA
Roof Board
APP-TA
APP-TA
Exterior Research and Design, LLC. d/b/a TrinitylERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report P9290.02.08-R8 for FL1654-R10
Revision 8: 12/06/2011
Appendix 1, Page 29 of 30
�.! TRINITY [ERD
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
Base Insulation Layer
Top Insulation Layer
Roof Cover
No.
Substrate
MDP (psf)
Type
Attach
Type
Attach
Base
Ply
Cap
Existing
Min. 1.5-inch ACFoam II,
Min. 0.25-inch DensDeck,
BP -AA, SBS-
(Optional) One or
R-10
asphaltic
ENRGY 3, H-Shield or ISO
OB500
DensDeck Prime or
OB500
AA, SBS-TA,
more BP -AA, SBS-
SBS-AA, SBS-
-127.5
roof
95+GL
SECUROCK Gypsum -Fiber
SBS-SA,
AA, SBS-TAor
TA, or APP-TA
Roof Board
APP-TA
APP-TA
Existing
Min. 1.5-inch ACFoam II,
BP -AA, SBS-
(Optional) One or
R-11
asphaltic
ENRGY 3, H Shield or Multi -Max
M OSFA
Min. 0.25-inch SECUROCK
M OSFA
AA, SBS-TA,
more BP -AA, SBS-
SBS-AA, SBS-
-157.5
roof
FA3
Gypsum -Fiber Roof Board
SBS-SA,
AA, SBS-TAor
TA, or APP-TA
APP-TA
APP-TA
Min. 2-inch ACFoam IV, min.
1.5-inch Ultra -Max or Multi -Max
Existing
FA-3, min. 1.3-inch ACFoam III
Min. 0.25-inch SECUROCK
BP -AA, SBS-
(Optional) One or
R-12
asphaltic
or min. 1.0-Inch ISO 95+GL, H-
CR-20
Gypsum -Fiber Roof Board
CR-20
AA
more BP -AA, SBS-
SBS-AA
-225.0
roof
Shield, H-Shield CG or ENRGY 3
AA
or min. 2.0 pcf ASTM C578
expanded polystyrene
Min. 2-inch ACFoam IV, min.
1.5-inch Ultra -Max or Multi -Max
Existing
FA-3, min. 1.3-Inch ACFoam III
Min. 0.25-inch SECUROCK
(Optional) One or
R-13
asphaltic
or min. 1.0-inch ISO 95+GL, H-
CR-20
Gypsum -Fiber Roof Board
CR-20
APP-TA
more APP-TA
APP-TA
-232.5
roof
Shield, H-Shield CG or ENRGY 3
or min. 2.0 pcf ASTM C578
expanded polystyrene
TABLE 7B: RECOVER APPLICATIONS
SYSTEM TYPE F: NON -INSULATED, BONDED BASE SHEET, BONDED ROOF COVER
Roof Cover
System No.
Deck
Primer
MOP (psf)
Base
Ply
Cap
Existing
(Optional if using asphalt
ing sphalt applied
R-14
asphaltic roof
PG100
applied
applied Ply)
Base) BP -AA, SBS-*AA, SBS TA or
A,
SBS-AA, SBS-TA, APP-TA
-45.0
APP-TA
Exterior Research and Design, LLC. d/b/a TrinityjERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report P9290.02.08-R8 for FL1654-R10
Revision 8: 12/06/2011
Appendix 1, Page 30 of 30