Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSi Date: C5-R`—i;k Fee Due: p Receint# Sec•! Permit # Qil)547)3r1 Planning & Development Services Building & Code Regulations Division ® 2300 Virginia Ave. sCq� Fort Pierce, FL 34982 Sf Q Ski (772)462-1553 CvC/o y C SPECIALTY PERMIT APPLICATION ��� ❑ Electrical ❑ Plumbing Q HVAC ❑ Fence ❑ Shed ❑ Demolition ❑ Gas ❑ Siding See page 2 for instructions and additional paperwork required for specialty permits 1. Location/Site Address: .E?,Ri(p T2&t ou, fl oir 2. Parcel ID Number: N -a5 •--jap' Cmy • `p(p Township Range Map Page Zoning Land Us c Initials Office Use Section Only 3. C 4. Owners Information 5. Contractors Information Name: t—kovi/la 1 l I J- NP q 1S FL Reg/Cert #: CRQQNDI� 12 Address: )j3 lQ - 0Ar County Cert#: ( aLA 13 City: ' Q�)jr' a UUCeA42State: f-U Business Name: 1 �-V CZU. Sf K,�PCMCW I CC41 Zip: Phone 1 F5qD Phone: 5TU- 211;)q Fax: 6. Value of Construction: $ t—I 9-N-CP OWNERS AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in compliance with all applicable laws regulating construction and zoning. Ce ?&Ir1"1 t CQ3 I PRINT OWNER OR CONTRACTOR NAME SIGN E OF OWNER R CONTRA STATE OF FLORIDA, COUNTY OF �(�..{ryl ACKNOWLEDGCDBEFOREMETHIS dj DAY OFNAM 20I2. BY ,Cat" I :� —— WHO IS PERSONALLY KNOWN TO ME 'OR WHO HAS PRODUCED jajLLl"d Gt=K AS IDCNTI noN. l NOTARY PUBLIC ' STATE CF FLORIDA SIGNATURE O NOTARY TYPE OR PRINT NAME # Y 9982 (seal) M Expires 417i 18 COMMISSION NUMBER NOTICLTOOWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. EXEMPT: A/C-H EAT REPLACEMENT WITH CONTRACT UNDER $7500.00 Revised 04/26/2010 i f NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. EXEMPT: A/C -HEAT REPLACEMENT WITH CONTRACT UNDER $5,000. ' INSTRUCTIONS Please complete all information in the space provided. All information must be printed (use blacic.or blue inlc only) or typed. This permit application is to be used only for those activities that are not otherwise included under a primary building permit, This application may not be used for any activity that includes structural alteration. The information to be provided with this application includes:. 1. Location/Site Address 2. Parcel ID Number 3. Description of Project or Work Activity 4. Owner Information S. Contractor Information -, . . :1 , , , • -- 6. Value of Construction Indicate the street address or general. location of property where the building activity is talcing place. Indicate the tax identification number of the property where the building activity is talcing place. Fully describe the activity to talce place. Indicate the name and address of the owner of the property onhicrf activityis taking"place. Indicate the State of Florida registration number (if applicable), St. Lucie County contractor license number and the name of the business doing the work. Indicate the total value oTthe work to talce place. Total cost of construction includes all current retail material arid labor costs associated with the building/construction activity. Construction value is used to determine the permit fee. St. Lucie County reserves the right to question and/or modify the indicated value of -construction if it is demonstrated that the submitted figures are not consistent with similar types -of construction. t ❑ Gas Attach 2 piping schematics with tank size; location, and BTU of eac appliance ❑ Shed: Attach 2 plot plans, 2 copies of DCA letter and plans,`2 anchor specifications ❑ Fence Attach 2 plot plans showing location of fence height of fence and type of fence ❑ Siding Attach 2 copies of manufactures specifications ❑ HVAC Attach 2 residential energy studies, 2 manuaf J calculations. 2 sets of duct layouts for new system. or full replacement This application can be submitted to St. Lucie County Building and Zoning, 2300 Virginia Avenue, Fort Pierce, FL 34982. All permit applications must be filled out completely before submission. No applications will be accepted for processing after 4:30 P.M. For: assistance in completing this application, please call-(772) 462-1.553, during regular,offce hours (8:00 AM - 5:00 PM), Monday through Friday. NOTE: Emergency electric service change out inspections will not be performed after 3: 00 PM without special arrangements and additional fee paid. Upon issuance of this permit, required inspections can be scheduled by calling (772) 462-1261. -�- Pre'd Summary Job: HUPMAN wrightsof® Date: May 19, 2012 Entire House n I If CJK EAST COAST MECHANICAL INC I i 1500 N HIGH RIDGE RD, BOYNTON BEACH, FL 33426 Phone: 561-586-3739 Email: EQUIPSALES@ECMSERVICE.COM Web: For: JANETTE HUPMAN 3816 FETTERBUSH CIR, PORT SAINT LUCIE, FL 34952 Phone: 772-340-1890 Notes: Weather: West Palm Beach, FL, US wintr.Cesign Cgnditiolls Outside db 47 OF Inside db 70 OF Design TD 23 OF Heating Summary Structure 18820 Btuh Ducts 5541 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh. Piping 0 Btuh Equipment load 24361 Btuh Infiltration Method Construction quality Fireplaces Area (ft2) Volume (ft3) Air changes/hour Equiv. AVF (cfm) Simplified Average 0 He 1710 Co 1710 13680 13680 0.38 0.20 87 46 Heating,Equipment. Summery Make Trade Model AHRI ref no. Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor . Static pressure Space thermostat 100 EFF 0 Btuh 23351 Btuh 15 OF 1400 cfm 0.057 cfm/Btuh 0 in H2O Summer Design: A�ondltions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 59 gr/lb Sensible Cooling Equipment Load Sizing Structure 24984 Btuh Ducts 9074 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 32356 Btuh Latent Cooling Equipment Load Sizing Structure 1823 Btuh Ducts 2384 Btuh Central vent (0 cfm) Equipment latent load 0 4207 Btuh Btuh Equipment total load 36563 Btuh Req. total capacity at 0.70 SHR 3.9 ton Cooling ,Equipment Summary Make Rheem Trade RHEEM RSPM SERIES Cond RSPM-AO42JK Coil AHRI ref no1076065 Efficiency 11.9 EER, 14 SEER Sensible cooling 29400 Btuh Latent cooling 12600 Btuh Total cooling 42000 Btuh Actual air flow 1400 cfm Air flow factor 0.041 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.89 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2012-May-19 09:18:17 .� wrilghtsoft• Right -Suite@ Universal 201212.0.04 RSU02217 Page 1 /(CGa Projectl.rup Calc=MJ8 FrontDoorfaces: N 05/21I2012 10:01 5614932-__ ECM — PAGE 02/03 Planning & Development Services Building & Code Regulations Division 2300 Virginia Ave. Fort fierce, FL 34982 (772)462-1553 SPECIALTY PERMIT APPLICATION ❑ El.ectric7.1 ❑ PlumbingFU(HVAC ❑ Fence ❑ Shed L] Demolition ❑ Gas Ll Siding i See page 2for instructions and additional paperwork required for specialty permits J<. Lorl�tion/Site Address: C. tC i 21 Parcel 1•ll Mamber: c.'� ' I F ice Use Only 3. Complete Description of Project or Worlc; ^.�1��•vrr; 3-��� 1 Range I Msln Pn�c Zon1n Land USO IafLi:tl3 -AIc- njAn vi/),o r"1 n4- 4, Owners 1'nforntati0n S. Contractors .Information i Name: �{• i/j �. Address: OAr City: Zip: � _ Pfione: ( ►7 6. Value I f Construction: $ -1-.Cx�) IM Reg/Cert #i: C,d aOcCC t 2 County Cert#, 1i 11siness Nnme: - ,�( j I CCci Phonei�i�P'_T'ax: 1' - (5 vNr rs Ar3,1DAV1Y: 1 certl-y that all oJ°the information contained in this appf ication is correet and that all work will be done in compliance with all applicable laws regulating construction and zoning, PRINT OWNf'R OR CONTRACTOR NAME SIGN E QP OWNGn R CON1'itA STATE Or FLORIDA, COUNTY OF ACKNOWLLDOrM BEFORI:': ME TI-I1S�� DAY QP 20� 2 BY WI101S PERSONALLY KNOWN TQ MI: OR WHO HAS t RODUCF1D I _ AS iDENTI ATfpN, Wes^ NOTARY PUBLIC STATE OF FLORIDA SIGNATUREO NOTARY TYPE ORPRTNTNAME 4i7= 2 (zeal) COMMISSION NUMBER_. _.. NOTICE, TO OWNER; PAt't,.URE TO RECORD A NOTICE Or CQtvIMpNCEMENi MAl' RESULT IN 11OUR PAYING TM.Cr fQR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT Wi•l-14 YOUR t.rNDER OR AN ATTORNEY BUITO'RY; RECORf)fNG YOUR NOTIGIT. or, COMMI?NC1t;MCNT. EXEMPTt A/C-TiEAT R'EPLACCMUNT WITH CONTRACT UNDER $7500,0D RcYlscd 002G 0.11} 05/21/2012 10:01 5614932 ECM PAGE 03/03 wrightsoft° Project Summary Entire Mouse EAST COAST MECHANICAL INC 1300 N H(GH RIDGE RD, BOYNTON BEACH, FL 33426 Phone:581.586.3739 sme(1: E0U1PSALES For: JANETTE HUPMAN 3816 FETTERBUSH CIR, PORT SAINT LUCIE, FL 34952 Phone: 772-$40-1890 Notes: Design Information Weather; I West Palm Beach, FL, US Job: HUPMAN Date: May 19, 2012 ey: CJK Winter Design Conditions Summer Design Conditions Outside db 47 °F Inside db 70 OF Outside db Inside db 90 75 OF Design TD 23 °F Design TD 15 °F Daily range L Relative humidity Moisture difference 50 59 gr/lb Heating Summary Structure 18820 Btuh Ducts 5541 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Pi in Equipment ipment load 24361 Btuh Infiltration Method Construction quality Simplified Average Fireplaces 0 Area (ft2) Heft 10 co1710 Volume (ftJ 13680 13680 Air changes/hour 0.38 0.20 Equiv, AVF (cfm) 87 46 Heating Equipment Summary Make Trade Model AHRI ref no. Efficiency 100 EFF Heating input 0 Btuh Heating output 23351 Btuh Temperature rise 15 °F Actual air flow 1400 cfm Air flaw factor Static pressure 0.057 0 cfm/Btuh in H2O Space thermostat Sensible Cooling Equipment Load Sizing Structure 24984 Btuh Ducts 9074 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 32356 Btuh Latent Codling Equipment Load Sizing Structure Ducts Central vent (0 cfm) Equipment latent load 1825 2384 0 4207 Stuh Btuh Btuh Stuh Equipment total load Req. total capacity at 0,70 SHR 36563 3,9 Btuh ton Cooling Equipment Summary Trade RHEEM RSPM SERIES Cond RSPMAO42JK Coil AHRI ref no1076065 Efficiency 11,9 EER, 14 SEER Sensible cooling 29400 Btuh Latent cooling 12600 Btuh Total cooling Actual air flow 42000 1400 Stuh cfm Air flow factor Static pressure 0.041 0 cfm/Btuh in H2O Load sensible heat ratio 0.89 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wriightsot° RlghtSuhe<IDunPogrsa1201212,0,04R91ro2217 2012.41y-1909:1817 PNedl.rup We-Md8 Fmntoaorfam: N Pop 05/21/2012 09:58 7724663?PP?,, SEACOAST AC PAGE 01 05/14/2012 13:14 7724G2,---_A1 ST LUCIE COUNTY PAGE 041.1 �T I L(1CIE 13UXLDZNrx 8: CODE REGULATION DXWSION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982 772-462-1553 FAX 7762 8 AUT14ORIZATION FORM FOR CREDIT CARD PAYMENT TO-' St Lucie County RE. - Permit # Credit Card Users: _1,5/o ,SrrrL,.hatge #ddedper tr ao7saction, Payments must: he received in this department by 4:00 PM for transattlon to be Pro ssed that day, if not it will be processed the fbilowing business day. VISA MA5MRCARD Credit Card Number, �t Expiration Date I Zip Code 3 digit security code Amount $ _ � + 1.5% surcharge Business Name: Authorized Print Names i . Phone: LIL) _ Fax: Comments; 51,CPQ5b ROViSed 4/01/2010 FN 05/21/2012 09:58 7724663�" SEACOAST AC PAGE 02 M Date: I Fee Due: Recei W Permit # Planning & Development Services Building & Code Regulations DivisioD �. 2300 Virginia Ave. Fort Pierce, FIL 34982 (772)462-1553 SPECIALTY PERMIT APPLICATION ❑ Electrical ❑ Plumbing ❑ 1IVAC L7 Fence ❑ Shed. ❑ Demolition 0 Gas ❑ Siding See page 2 for instrucdons and addiifonul,papenvork required fvr sp¢cialty permilS 1. Location/Site Addressjf ` /1` 2. Parcel U) Number, 1� � ` � -� `—'� � ` l Township Only Zoning 3. Com le Description of Projector r[c: LIKE FOR LIKE. CUAE4UN V. t � r 4. Owners Information , 5. Contractors In'formatlon Name: A i FL Deg/Cent #: __rA ran h r A d A Address: County Cert#: $_2 3 City -� State: Business Name: SEA-_ COAST AC Zip:• �_J - U °' Phone • r" Phone;466-2400 Fax: 772-466-3053 6. Value of Construction: $+r~ OWNER'S AFRIDAVii: I certify that all of the informatUlon contained ua t}i application ' ect at all work will he done iu compl.iauce with all applicable laws regulating strnc 'oin !I ,TORN_ ��?•AN�',�,L,.R PRINT OWNER OR CONTRAC fOR NAME SIGN . OF O It OR CONTRA :TOR STATE OF'FLORIDA,COUNTYOF ST. I,UCIE �O& ACKNOWLEDOED BEFORE ME THISDAY OF BY �Lroi�N V LAATGEII•_ IS PERSONALLY M4CAW TO MF �; _ OR WIIO HAS FIROD D — TRACY LANM 3GNATME E IFICA NOTARY PUBLIC CX— �n/�p —Tracyn 1 STATE OF �$M 0 AIL Type OR PRINTNAME OF NOTARY coNWSSIONNLNMER EEO 21 9 ZS— B/3613p14 NOTICE TOOWNIM FAILURE TO RECO" A NOTICE Or COMMENCEMENT MAY RiESU"'C IN YOUR PAYING TWICE FOR I,MPROVEMENT5 TO YOUR PROPERTY. IF YOU INITNA TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY HEFORR RECORDING YOUR NOTICE OF COMMENCEMENT, EXEMPT: NC -HEAT REPLACEMENT WITH CONTRACT UNDER S7500-DO Revised 04/26I2010 05/21/2012 09:58 7724663`�' SEACOAST AC PAGE 03 This aorlthTgiltianj. wel es foi�'aiFgdersl Energy "imp � ;F !y;��,J,. • .. r clan Yt It ret!<It'w�ti��ih,pl""""•In service Eifl•: a 2011. rdsm 1 bstWdAit; .,.!',"17r' 8 slnd,bpc 1, C. cd.eil Praut- tin-gs AHRI Certlfled Reference Number: 38.69097Date: 5121/ U12 Product: Split System: Alr-CooledCondensing Unit, Call with Blower Outdoor Unit Model Number,14ACX-041,230' Indoor Unit Model Number: CBX27UH-048-230-+Te E Manufacturer: LENNOX INDUSTRIES, INC. Trode/Brand name,,.14ACX'SA.RIES ' Manufacturer responsible for the rating of this system combination is LENNOXINDUSTRIES, INC. Heat Pum polEquipment ndasub ewith et to RrifIca�tion of rating accuraacy► byAHRI-sary ponsored, Indep� dent third Party teang; Cooling Opacity Pull): 39000 EER Rating (Cooling):.... 13.00 SEER Rating'(C.00ling): 16.00 v ' RaUnps followed by on aaa�l�k ('� triaceb a vohm>SY + of R�rY Pei dole, melees a000�nparYed wnh a w+�S, wntri� trtQaalOs en Imld�m�Y nnt+. � D)sl;CI.AIM0 AHRI dw not aiiloM t%prodildt O NO oil dds CwWlaetd Mid mdm no atlM or d`uiMtW et tip; ow spui ""a iwponst" fot, the Wxwegs) Maud on tnis Cady dL AHM wWVB y &wh& + IN NOW for sr0et�+at wW Idnd sew at of dN wo or IMrtamwm orm. pro kmo), arti,e 1r�eifNlalrsd aN�wtfon at data Ill d1 tl+ts GNtlasb, nitlnps sus.r�d aWy tar models end C#MipiNallons AsiAd (n du dN�toly etwwwaltifdtreemryarg. TERMS AND CONDMOM Th4 GAlftoaM and Nil OA1ltpinm ant p1ap111tMy P of Al IRL clds Cerd6ade o1Mlr 6t used far hidiVlAint, P M M� I�Idw, ff ��a p41n WV 1 Pis aontwRi ofto c wftds "W 114In who* a in pod, he mpWu md; FapW,. diem *uftd; rr�W IN MtO� • dststwse; Qr G++wMse> d+Y fam or nwswr or by goy rtwals, +xs+Pttorths wer's s+dEviduat, pwscr+ri and coMldentllst �irlN er a CUM FICATE VEFURCATI ON The kdamadilaiwow modNdW WUNs oerl oftQai1bsvotn.datwww.etnidtreMY-wV, Air -Conditioning, Healing, dkkon'vearrcatdiosa*Anx.ndennrllh.wl I dR.dRdewr+c•Nunb�radf>bd,esonAMIand RehlMewflon Inafltuts which the a llsne+cx moss Wvat, wlMen is wad sbNk sW chs CwditMe ism, wirod It NOW II tw- 02012 Air-Conditloning, Heating, and Refrigeration Institute CERTIFICATE NO.: 1=08301819N0093 Property Appraiser - St.Lucie C ity, FL Page 1 of 1 PROPERTY RECORD CARD Janette E Hupman Record: 1 of 1 <<Prev Next » Spec.Assmnt Taxes Exemptions Permits Home Print Property Identification ��UCIECO Site Address: 3816 Fetterbush Court ParcellD: 3425-706-0094-000-6 Sec/Town/Range: 25:36S :40E Account #: 141395 Map ID: 34/25N Land Use: Mob Homes Zoning: PUD City/Cnty: St Lucie County Ownership and Mailing Legal Description Owner: Janette E Hupman THE PRESERVE AT SAVANNA CLUB- BLK 46 LOT 36(OR 1508-928: Address: 3816 Fetterbush Ct 2988-1214) Port St Lucie FL 34952 Sales Information Assessment 2011 Final Total Land and Building Date Price Code Deed Book/Page 2011 Final: 68600 Land Value: 16000 Acres: 0.12 6/24/2008 100 01 QC 2988 / 1214 Assessed: 68600 Building Value: 52600 3/26/2002 0 01 LE 1508 / 0928 Ag.Credit: 0 Finished Area: 1772 SgFt 1/1/1900 0 / Exempt: 68600 Taxable: 0 Taxes: 434.07 Exterior Features View: - ExtType: MHA - MHA Grade: SAVL - SAVL StoryHght: 0010 -1 Story Interior Features BUILDING INFORMATION RoofCover: - YearBit: 2001 EffYrBlt: 2001 No.Units: 1 RoofStruct: - Frame: - PrimeWall: - SecWall: - BedRooms: 0 Electric: - PrmintWall: - FullBath: 0 HeatType: FHA - FrcdHotAir AvgHUFI: 1/213ath: 0 HeatFuel: ELEC - Electric Prm.Flors: - %A/C: 100 %Heated: 100 %Sprinkled: 0 Special Features and Yard Items Land Information Type Y/S Qty. Units Qual. Cond. YrBlt. No. Land Use Type Measure Depth 1 0200-Mob Homes 165 -Flat 1 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED. http://www.paslc.org/paslc/prc.asp?prclid=342570600940006 5/21/2012