Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SUBMITTED PAPERS
Apr 2712 08:54a Wolf Air Conditioning 772-464-1127 p,1 Date: 27 A Fee Due: Recei t# Permit # Planning & Development Services Building & Code Regulations Division 2300 Virginia Ave. Fort Pierce, FL 34982 `UC .1@ V (772)462-1553 CO(Jf)hl SPECIALTY PERMIT APPLICATION ❑ Electrical ❑ Plumbing Yd'HVAC ❑ Fence ❑ Shed ❑ Demolition ❑ Gas ❑ Siding See page 2 for instructions and additional paperwork required for specialty permits 1. Location/Site Address: I �� E /� �S k_ 2. Parcel ID \umber: 3 G `y(o .?- Township Range Map Page Zoning Land Use Initials t: Section Oniy 1,4 11 S • 3 3. Complete Description of project or Work: c--c r 4. Owners Information 5. Contractors Information Name: ' -.'Jv g S Marx -&u-m FL RegiCert#: Address:[ 061 5 f- 5 County Cert#: C::2 C < p j City: f`l -- `�' •^<<- State: 1 Z Business Name: Zip: -3e� f ,- Phone: (, �t5�, Phone:-%2WFax• `` Lt! 6. Yalue of Construction: $ 45� OWNER'S AFFID aVIT: I certify that all of the information contained in this application is correct and that all work will be done in compliance with all applicable laws regulating cons tion and zoning. PRINT ER OR CONTRACTORNAME e S]QgAF OWNER OR CONTRACTOR e STATE OF FLORIDA, COUNTY OF �—' v ACKNOWLEDGED BEFORE ME THIS DAY OF ( , 20 I - BY 6?F3. J + WHO IS PERSONAL KNO WN fO ME OR WHO HAS PRODUCED rn .c,ti O;y AS 4ENT]FICATION. 5 G AT E O OTARY TYPE ORP T N Atv1E O F NOTARY ��. � �' a COMMISSION NUMBER NOTICETOOWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY, IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. EXEMPT: A1C-nEAT REPLACEMENT WITH CONTRACT UNDER $ 7500.00 Revised 0412612010 Apr 271208;54a Wolf AirConditinnng 7712-464-1127 p.3 Certificate of Product Ratin AHRI Certified Reference Number: 5038876 Date: 416I2012 Product: Year -Round Air -Conditioner, Remote Air -Cooled Condensing Unit Outdoor Unit Model Number: SSX160361B* Indoor Unit Model Number: CA*F4860*6D*+TXV Furnace Model Number: G*E8080SC*13* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade/Brand name: GOODMAN, JANITROL, AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 2101240.2008 for Unitary Air -Conditioning and Air -Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): 34200 ``R Ra'u . ,ire .an �y wvwu iy). SEER Rating (Cooling): 15.50 P,atinos fallewed bV an asterisk f7 indicate a voluntary rerate of oreviousiv euolished data, unless aceornoanied wit-i a WAS. wh ch indicates an invo untary rera:e. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibilityfor, the products) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising outof the use orperformance of the product(s), or the unauthorized alteration of data fisted on this Certificate. Certified ratings arevalid only for models and configurations listed In the directory at wwt'j.anddirectory.org. TERMS AND CONDITIONS This Certificate and Its contents are proprietary products of AHRI. This Certificate shall only be used for Individual, personal and confidential reference purposes. rile i.iYlitahis i7i :i iia vCi iin�aia may uoi, iu �rir.ne u. in port, ue,oYuuu�.c<i, wyio�, .iiaamiw,a reu, r,i,�reri mus a wu.Nuier va.eoaoc, CA 6u rcwunt: uiiimad, in aUy form or manner orby any means, except for the user's individual, personal and confidential reference, CERTIFICATE VERIFICATION The information forthe model cited on this certificate can be verified atwww.ahridirectory.org, w �© Air -Conditioning. Heating, click on "Verify Certificate" link and enter theAHRI Certified Reference Numberand the date on pm. On rI and Refrigeration Institute which the certificate was issued, Which is listed above, and the Certificate No.. which Is listed below. ©2012 Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.; 12378201739487066o Apr 27 12 08:55a Wolf Air Condit yoi.g 779-454-1127 p.4 RUt2D. Qes ig nStar Load Calculation Results are intended for use with Ruud beating and cooling systernsonly Location; Street Address 1601 easy st , SAINT LUCIE, FL 34962 Latitude, Longitude 26.6726', -80.0706' House Square Footage: 1693 sq. R Name: ED BLUM Phone: Email: Outdoor Dry bulb (OF) Daily range Relative humidity Moisture difference Indoor Indoor temperature (OF) Design temperature difference(F) Heating Cooling 47 90 M 50 % 64 Heating Cooling 70 75 23 15 Area Btuh % of load Wall 1903 10.5 Floor 4908 27.1 Ceiling 2064 11.4 Windows 2795 15.4 Infiltration 4780 26.4 System Efficiency Loss 1645 9.1 Total: 18094 Heating Loads ETU-i Y Floor System Efficiency Loss Ceiling Infiltratlon J Windows I Apr 2712 08:55a Wolf Air Condit;^-'r,g 770 a54-1127 p.5 Area Btuh % of load Wall 1241 3.8 Ceiling 1346 4.2 Windows 15169 46.9 Sensible Infiltration 2338 7.2 Latent Infiltration 6167 19.1 System Efficiency Gain 2526 8.1 Intemal 1900 5.9 Sensible People Load 779 2.4 Latent People Load 779 2.4 Total: 32344 Sensible load 25396 Latent load 6946 SHR 0.79 Capacity at.75 SHR 2.82 Tons Cooling Loads 32'.ca1 31 U!iiC Wlndoms Sensible People Load Latent People Load 1 r---- Wall 3 arnai Sensible lnfilaatit System Efficiency Latent infiltration i • • • �t�rt�.:ra:�.t•>tyncay�vca�.-�r►• AED Graph Sam 9a.,n 10am 11am 12pm 1pin 2pm 3pm 4orn 5am 6pm 7pm 8p,- — Hourly Loads — Average System equipment selection will be made using the fdloMrig Manual S derived values Summer Outdoor 90'F Summer Wet Bulb 760F Summer Indoor 75°F Summer Design Grains 50% Winter Outdoor 47°F Apr 2712 08:55a Wolf Air Condit;- ,,-g 77-454-1127 p.6 Winter Indoor 70"F Sensible Coding 25,398 Btuh Latent Coding 6,946 Bfuh Required Coding Ai. flav 1,154 CFM Sensible Heating 18,094 Btuh Required Heaing Airflow 235 CFM All calculations are based upon approved hvac industry standards and procedures, and comply with all local, state and federal code requirements. All computed results are Estimates. Product provided by Energy Design Systems and Idea Tree Property Appraiser - St.Lude Cot,-'-,,, FL Page 1 of 1 Edward A Blum Record: 1 of 1 Property Identification Site Address: 1601 Easy St Sec/Town/Range: 11 :36S :40E Map ID: 34/11S Zoning: RS-3 Ownership and Mailing Owner: Edward A Blum Marie L Blum Address: 1601 E Easy St Fort Pierce FL 34982-8605 Sales Information Date Price Code 2/1 /1979 10500 02 E.(m) PROPERTY RECORD CARD <<Prev Next» Spec.Assmnt Taxes ParcellD: 3402-610-0625-000-3 Account* 38710 Land Use: SF Res City/Cnty: St Lucie County Exemptions Permits Home Print 0, Legal Description INDIAN RIVER ESTATES-UNIT-09- BLK 92 LOTS 31, 32 AND 33 (MAP 34/11 S) (OR 304-571) Assessment 2011 Final Total Land and Building Deed Book/Page 2011 Final: 104400 Land Value: 40300 Acres: 1.25 CV 0304 / 0571 Assessed: 104400 Building Value: 64100 Ag.Credit: 0 Finished Area: 1693 SgFt Exempt: 75000 Taxable: 29400 Taxes: 1082.65 BUILDING INFORMATION Exterior Features View: - RoofCover: FS - Fibrglss Shg RoofStruct: HP - Hip ExtType: HC - HC YearBlt: 1980 Frame: - Grade: C - C EffYrBlt: 1980 PrimeWall: BS - CB Stucco StoryHght: 0010 - 1 Story No.Units: 1 SecWall: - Interior Features BedRooms: 2 Electric: MX - MAXIMUM PrmintWall: DW - Drywall FullBath: 2 HeatType: FHA - FrcdHotAir AvgHt/FI: 1/2Bath: 0 HeatFuel: ELEC - Electric Prm.Flors: CU - Carpet %A/C: 100 %Heated: 100 %Sprinkled: 0 Special Features and Yard Items Land Information Type Y/S Qty. Units Qual. Cond. YrBlt. No. Land Use Type Measure DWC - Driv-Concret Y 1 2100 AV AV 1980 1 0100-SF Res BI -Front Ft 198 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED Depth 275 http://www.paslc.org/prc.asp?prclid=340261006250003 4/27/2012 Planning & Development Services Building & Code Regulation Division Permitting Department Receipt 2300 Virginia Avenue Fort Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Date: 27 April 2012 Receipt M 0000085189 Permit Number: 1204-0378 Job Address: 1601 EASY ST \mount: $87.36 Paid With: VS Check Number: Paid By: WOLF AIR CONDITIONING Received By: eileenn 5196 Online address: http://www.stlucieco.org/planning/permitting.htm Quick Links Permit Status Lookup Online Building Inspection System a Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone: (772) 462-2172 Fax: (772) 462-6443 BUILDING PERMIT Online address: http://www.stlucieco.org/planning/permitting.htm Quick Links Permit Status Lookup Online Building Inspection System Permit #: SLC 1204-0378 Conf #: 574 Issued: 04/27/2012 Job Location: 1601 EASY ST City: FORT PIERCE Permit Type: Mechanical/HVAC Residential Job Description: REPLACE GAS FURNANCE AND CASE COILAND CONDENSER WITH NEW FURNACE, COILAND CONDENSER. 15.50 SEER. MANUAL &AHRI CERT SUBMITTED WITH PERMIT APPLICATION. Subdiv: Indian River Estates Unit 9 Lot: 31-33 Block: 92 Parcel: 3402-610-0625-000/3 Setbacks Left: Right: Front: Rear: Zoning: RS-3 Number of Units: 1.00 Floors: 1 Buildings: 1 Square Footage: 0.00 Minimum Floor Elevation: Flood Map: Flood Zone: Elev: Contractor WINN, LOGAN 3785 OLEANDER AVE Property Owner EDWARD A BLUM WOLF AIR CONDITIONING & HEATING (772) 464-8298 FT PIERCE, FL 34982 (772) 465-8136 1601 E EASY ST FORT PIERCE, FL 34982-8605 �--�, _=-�_�------t�..__-.__-_____�...�__:_---.�--_-�_u-�-=-:-__--�:���:;�-�----:�-_=.--�_---�� �_--•--_�.-may,—�_��.��� Property Owner MARIE L BLUM 1601 E EASY ST FORT PIERCE, FL 34982-8605 Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code including those for all electric, plumbing, mechanical, roofing and structural work. Further, he/she acknowledges responsibility to comply with all requirements of the 2007 Florida Building Code and the St Lucie County Land Development Code. Issuance of this permit may be appealed to the St Lucie County Board of Adjustment by an aggrieved party by filing a notice of appeal with the St Lucie County Growth Management Director within thirty (30) days of the issuance of this permit in accordance with St Lucie County Land Development Code, Section 11.11.00., Appeals. Building Permits shall expire and become null and void if work authorized by such Building Permit is not commenced, having called for and received a satisfactory inspection, within six (6) months from the date of issuance of the permit, or if the work is not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date of issuance of the Building Permit in accordance with St Lucie County Land Development Code Section 11.05.01 (A)(2). NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. s:553.79(10), F.S. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s:713.135 (1)(a), F.S. Kenneth Arnold Building Official Date INSPECTION CARD Planning & Development Services Online address: Building & Code Regulation Division http://www.stfucieco.org/planning/permitting.htm 2300 Virginia Avenue Quick Links Fort Pierce, FL 34982 Permit Status Lookup Phone: (772) 462-2172 Fax: (772) 462-6443 Online Building Inspection System Permit #: SLC- 1204-0378 Confirmation #: 574 Status ISS Issued: 04/27/2012 Type: Mechanical/HVAC Residential Job Location: 1601 EASY ST City: FORT PIERCE Jurisdiction: St. Lucie County Parcel: 3402-610-0625-000/3 Subdiv: Indian River Estates Unit 9 Lot: 31-33 Block: 92 Flood: Elev: Flood Map: Setbacks Left: Right: Front: Rear: Job Description: REPLACE GAS FURNANCE AND CASE COIL AND CONDENSER WITH NEW FURNACE, COIL AND CONDENSER. 15.50 SEER. MANUAL J & AHRI CERT SUBMITTED WITH PERMIT APPLICATION. Contractor WINN, LOGAN WOLF AIR CONDITIONING & HEATING (772) 464-8298 3785 OLEANDER AVE FT PIERCE, FL 34982 Property Owner EDWARD A BLUM (772) 465-8136 1601 E EASY ST FORT PIERCE, FL 34982-8605 Property Owner MARIE L BLUM ( ) - 1601 E EASY ST FORT PIERCE, FL 34982-8605 SUB -PERMITS Permit # Status PT Cert # DBA Owner / Builder Job Description Inspection Notes: For the automated inspection system call (772)462-1261. To schedule an inspection online go to http://airs.slcfl.vetrol.com/AIRSweb.php. All inspections requested prior to 9:00 PM will be scheduled for the next business day. Inspection requests between 9:00 PM Friday and 9:00 PM Monday will be scheduled for the following Tuesday. If you require any assistance, please contact the Building Department at (772) 462-2172. Permit # Type Code Description Priori Date Sched. Res Description Inspector Date Insp. 1204-037f 380 Mechanical Final 1 1204-037f 999 Final Inspection 1 Permit Nun 1204-0378