HomeMy WebLinkAboutSUBMITTED PAPERSDatqff
� i
r • _ 1,�.
Planning & Development Services
Building.& Code Regulations Division
2300 Virginia Ave.
Fort Pierce, FL 34982
(772)462-1553
ScAl%so
St. Lucay
ie CcUnty
SPECIALTY PERMIT APPLICATION
❑ Electrical ❑ Plumbing 01 HVAC ❑ Fence
❑ Shed ❑ Demolition ❑ Gas ❑ Siding
See page 2 for instructions and additional paperwork requiredfor specialty permits
1. Location/SiteAddress: "70U® `�oCre4 PIn � C11"c�i>u
2. Parcel 1D Number: _ 50q — CX�0 ( -- E pp — 1
Office Use
Section
I
Township
Range
Map Page
Zoning
Land Use
Initials.
Only
2
DM
3. Complete Description of Project or Work:
4. Owners Information 5. Contractors Information
Name: Carol FL Reg/Cert #:
Address: n OLOC> -Torres A`rses Cinch, County Cert#:
City: �(2LV S+. Wdif_ State:
r L, - Business Name:
Zip: 3 L461 g Lp, Phone: (eV - q6,;k3 Phone: --_3q$-q0 LV'9 Fag:
6. Value of Construction: S a at� _ cc�r 3
OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in
compliance with all applicable laws regulating constructs I zoning.
PRINT OWNER CONTRACTORNAME °° SIGNATURE OF OWNER OR CONTRACTOR
GA -,STATE OF FLORIDA, COUNTY OF G, L,,, s� �r� /1�
ACKNOWLEDGED BEFORE ME THIS " DAY OF 1 � 20,� BY i �%G� Ll.( f
WHO IS PERSONALLY KNOWN TO ME OR WHO HAS PRODUCED
IDENTIFICATION. J �y /��1
wl `� v 0 Notary Public Sta a of. Florida
SIG ATURE OF NOTARY TYPE OR PRINT NAME OF NOT AR Deborah RusS
�� My Commission EE038992
CONWSSION NUMBER or n°� Expires I1105/2014
NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITTI YOUR
LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT:
EXEMPT: A!C-HEAT REPLACEMENT WrM CONTRACT UNDER 97980.40
Revised 04/26/2010
Job
1 HTSOFT Pro ect Summa Dat �s
- Date: April28.2012
Codler-Sy Design Entire HoYse By: Shawn Russell
Email: 2shawnruswll@bellsouth.net '11 ` _
P• • •
For: Bruce Bredickas, Amtek Air Cond
7060 Torrey Pines Cir, Port Saint Lucie, FL 34986
Email: 2shawnrusseli@bellsouth.net
Notes:
DesignInformation, h
Weather: W Palm Beach, FL, US
Winter Design Conditions
:Outsidedb47
OF
Inside db
70
OF
Design TD
23
OF
Heating Summary
Structure
17902
Btuh
Ducts
4701
Btuh
Central vent (0 cfm)
0
Btuh
Humidification
0
Btuh
Piping
0
Btuh
Equipment load
22604
Btuh
Infiltration
Method
Construction quality
Fireplaces
Simplified
Average
0
Heating Cooling
Area (ft�
1753
1753
Volume (ft)
15777
15777
Air phanges/hnur
b.38
0.20
Equiv. AVF (cfm)
100
53
Heating Equipment Summary
Make
Trade
Model
,AHR,I ,ref nq. No
Efficiency
Heating Input
Heating output
Temperature rise
Actual air flow
Air flow factor .
Static, pressure
Space thermostat
100 EFF
0 Btuh
22296 Btuh
15 OF
1333 cfm
0.059 cfm/Btuh
0 in H2O
Summer Design, Conditions
Outsidi= di
J0 -°:F
Inside db
75 OF
Design TD
15 OF
Daily range
L
Relative humidity
50 %
Moisture difference
59 gr/Ib
Sensible Cooling Equipment Load Sizing
Structure
22865
Btuh
Ducts
10954
Btuh
Central vent (0 cfm)
0
Btuh
Blower
0
Btuh
Use manufacturer's data
n
Rate/swing multiplier
0.95
EgOpmepl sensibl�)gasi
32195
Stuh
Latent Cooling Equipment Load Sizing
Structure
2091
Btuh
Ducts
2226
Btuh
Central vent (0 cfm)
0
Btuh
Equipment latent load
4316
Btuh
Equipment t9t,s119 i
36512
,B uh;
Req. total capacity at 0.70 SHR
3.8
ton
Cooling Equipment Summary
Make Rheem
Trade RHEEM 14AJM SERIES
Cond 14AJM42
000 RHU-HM_ 8521++RC!1A2.1.
AHRI ref no. 3806012
Efficiency
13.0 EER, 16 SEER
Sensible cooling
28000 Btuh
Latent cooling
12000 Btuh
Total cooling
40000 Btuh
Actual air flow
1333 cfm
Air flow factor
0.039 cfm/Btuh
Static pressure
0 in H2O
Load sensible heat ratio
0.89
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
Wrl htsott" 2012-Apr-26 14:17.45
ACC ,..._: 9 Right-Suite®Universa12012 12.0.04 RSU09070 Page 1
C:k mm'Shamm RusslMocumennts'ALL ARIGHT SOFT ih1€OISMICKES.rup talc = NV8 Fart f aor fac s:
This combination qualifies for a Federal Energy
Efficiency Tax Credit when placed in service
between Feb 17, 2009 and Dec 31, 2011.
Certificate of Product Rating's.
AHRI Certified Reference Number: 3806012 Date: 4/26/2012
Product: Split System: Air -Cooled Condensing Unit, Coil with Blower
Outdoor Unit Model Number: 14AJM42
Indoor Unit Model Number: RHLL-HM3821+RCSL-H*3821
Manufacturer: RHEEM MANUFACTURING COMPANY
Trade/Brand name: RHEEM 14AJM SERIES
Manufacturer responsible for the rating of this system combination is RHEEM MANUFACTURING COMPANY
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air -Conditioning and Air -Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third
party testing:
Cooling Capacity (Btuh):
40000
EER Rating,(Cooling): .....
13.00
SEER.Rating (Cooling):
16.00
Ratings followed by an asterisk (') indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate.
DISCLAIMER
AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for,
the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the
unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectoryorg.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products of AHRL This Certificate shall only be used for Individual, personal and confidential reference purposes.
The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any
form or manner or by any means, except fortre user's Individual, personal and confidential reference.
CERTIFICATE VERIFICATION
The Information forthe model cited on this certificate can be verified at wwmahridirectoruorg, ' Air -Conditioning, Heating,
dick on "Verify Certificate" link and entertreAHRI Certified Reference Number and the date on 0,11111 so IL/ and Refri eration Institute
which the certificate was issued, which Is fisted above, and the Certificate No., which Is listed below, g
02012 Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129799333830801274
S
Property Appraiser - St.Lucie ; vnty, FL
Page 1 of 1
Bruce R Bredickas
Record: 1 of 1
Property Identification
Site Address:
7060 TORREY PINES CIR
Sec/Town/Range:
22 :36S :39E
Map ID:
33/22N
Zoning:
PUD
PROPERTY RECORD CARD
«Prey Next» Spec.Assmnt Taxes Exemptions Permits Home Print
ParcellD: 3322-504-0031-000-1
Account* 143770
Land Use: SF Res
CityiCnty: St Lucie County
Ownership and Mailing
Owner. Bruce R Bredickas Carol A Bredickas
Address: 7060 Torrey Pines Cir
Port St Lucie FL 34986-3200
Legal Description
POD 7B REPLAT AT THE RESERVE PUD I TORREY PINES LOT 20D
(OR 3187-196)
Sales Information
Assessment 2011 Final
Total Land and Building
Date Price Code
Deed Book/Page
2011 Final:
157000
Land Value: 30000 Acres: 0.06
3/31/2010 180000 0001
WD 3187 / 0196
Assessed:
157000
Building Value; 127000
6/29/2002 220500 00
SP 1540 / 0928
Ag.Credit:
0
Finished Area: 1753 SgFt
Exempt:
Taxable:
Taxes:
3194.28
BUILDING INFORMATION
Exterior Features
View.
-
RoofCover.
TC - Clay Tile
RoofStruct
HP - Hip
ExtType:
HB-- HB-
YearBlt:
2002
Frame:
-
Grade:
B- - B-
EffYrBit:
2002
PrimeWall:
BS - CB Stucco
StoryHght
0010 -1 Story
No.Units:
1
SeCWall:
-
Interior Features
BedRooms:
2
Electric:
MX-MAXIMUM
PrmintWall:
DW- Drywall
FullBath:
2
HeatType:
FHA - FrcdHotAir
AvgHt/Fl:
1/28ath:
0
HeatFuel:
ELEC - Electric
Prm.Flors:
CU - Carpet
%A/C:
100
%Heated:
100
%Sprinkled:
0
Special Features and Yard Items
Land Information
Type
Y/S Qty.
Units Qua[. Cond.
YrBlt No. Land Use
Type
Measure Depth
SDSF - SITE DEV S-F
Y 1
1 AV AV
2002 1 0100-SF Res
SVI -Site
1
WAL4 - CBSWall8'Blk
Y 1
32 AV AV
2002
THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED
http://www.paslc.org/prc.asp?prclid=332250400310001 4/26/2012
MOMPLANNING AND DEVELOPMENT SERVICES DEPARTMENT
BUILDING AND CODE REGULATIONS DIVISION
• 2360 VIRGINIA AVE,
FORT PIERCE, FL 34982
(712)4624553 Fa: (772)462-1579
PERMIT RENEWAL REQUEST
PERMIT NUMBER: l n (D 4 ._ j�30oi ADDRESS: e-6—) 1 • D e' C_G�' ('
71 am requesting that the above .permit be renewed. I
understand tI at must schedule and pass all required inspections for the permit to be finaled. ' Further, I
understand that this is a ONE TIME RENEWAL and the permit shall expire should'I not receive a
passing;inspeetion during any six month: period. during the renewal period.
Justification-t M4-Q �n
f car -i-p �C' D� QcQt e� `in2fi P n� ► 5nneCt
LP,11 3!
DATE
Print Name -
STATE OF FLORIDA
COUNTY QF _S 11. N e . ..
P
ACKNOWLEDGED BEF/O�RE ME ., THIS DAY OF (3LLX .20
BY C 11�ax� 1_ q a,' c 1 WHO IS. PERSONALLY KNOWN TO ME �OR
13AS PROVIDED AS IDENTIFICATION..
SIWT.E I OF FLORIDA, County of .._ L—a .
SIGNATURE OF NOTARY r I'll
SEAL °tr SEAL DEBORAH RUSSELL
?+ �"•°�: Notary Public - State of Florida
+ r •c
Commission # FF 179630
ag
FOR OFFICE USE ONLY:
Number o€'Open Inspections:
Total Inspections:
(Divide open by total to get % of open inspections)
Percentage. -
Original permit fee: x %open = $ Renewal fee
Example: (15 divided by 23=.65(°/o)] $175(permit fee) x .65=S 113`.75 (renewal fee)
Revised 7121n014