Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SUBMITTED PAPERS
DATE: 47-0. /,2 I FEES DUE: V.,S& RECEIPT #: Permit #: / 20 r Planning & Development Services Department Building & Code Regulation Division SCANNED 2300 Virginia Avenue Ft. Pierce, FL 34982-5652 BY Tel.772-462-1553 St. Lucie County APPLICATION FOR ROOF PERMIT SEE REVERSE SIqE FOR INSTRUCTIONS 1. Location/Site Address: Ayienk2 M . 2. Parcel ID Number: ago'5 3. 4. 6. Office Use Only Section I Township Range I Map Page I Zoning Land Use I Initials 1 GS 135.5 1yd C 0,5-jq IRS- 0 Description of Project or Work Activity: CL3 0 5A i lle-, f'le Total Roof Area (square feet): ;�24 UO 5. Roof Pitch: _ 7— Type of Roof: [ fiberglass Shingle [ ] Concrete Roof Tile [ ] Wood Shake / Shingle [ el"Tar ar & Gravel [ ] Modified Bitumen [ ] Other [ ] Product Approval required for all types of Roofing Material (2 Sets) ] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product Approval attached ** Roof Mitigation per F.S. 553.844 will be required. 7. Owner Information 8. Contractor Information i Name: o�/ k 1_�j� ! 1 ��uOl,aa, Nicite- Address: 3 5?o 6/ e n l i e 1� . City: f State: r L Zip: Phone: - 0 9. Value of Construction: $ 7`3:�)4 FL Reg/Cert #: CCCZ 5__3-;L_7 County Cert #: d q0 % a Business Name:" l 6�-�A} 6- t Cell Phone: "Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval. CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in compliance with all applic ble 3 regulating construction and zoning. iT QUALIFIERS/OWNERS NAME IGNA OF QU L IER/OWNER STATE OF FLORIDA, COUNTY OF ACKNOW LEDG BEFORE ME THIS DAY OFMALZ 20� BY WH S NA Y O TO ME OR HAS PRODUCED AS��rj[SL�ITFISOR y �Gj�j�OwElve NOTARY PUBLIC G SAT OTA TYPE OR RINT NAME OF NOTAI�`STATE OF FLORIDA COMMISSI NUMBER 3 lv JComm# EI=149903 Expires 3/10/2016 NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Revised 4/26/2010 Property Appraiser - St.Lucie County, FL Page 1 of I _o PROPERTY RECORD CARD Joseph P Noble Record: I of 1 «Prev Next >> Spec.Assmnt Taxes Exemptions Permits Home Print Property Identification IE Site Address: 3807 Avenue N ParcelID: 2405-601 -0468-000-2 Sec/Town/Range: 05:35S :40E Account #: 18724 Map ID: 24/05N Land Use: SF Res Zoning: RS-4 City/Cnty: St Lucie County Ownership and Mailing Legal Description Owner: Joseph P Noble Pauline Noble SUNLAND GARDENS BLK 26 LOT 2 (0.18 AC) (OR 232-790: 3148- Address: 3807 Ave N 2913: 3237-2861) Fort Pierce FL 34947-1826 Sales Information Assessment 2011 Final Total Land and Building Date Price Code Deed Book/Page 2011 Final: 32500 Land Value: 4900 Acres: 0.18 10/13/2010 100 0111 QC 3237/2861 Assessed: 29734 Building Value: 27600 11/30/2009 100 0111 QC 3148/2913 Ag.Credit: 0 Finished Area: 960 SqFt 1/1/1900 0 Exempt: 25000 Taxable: 4734 Taxes: 96.32 Exterior Features View: RoofCover: FS - FIbrgIss Shg RoofStruct: GA - Gable ExtType: HC-HC YearBlt: 1970 Frame: Grade: D-D EffYrBit: 1977 PrimeWall: BS - CB Stucco Storyllght: 0010-1 Story No.Units: 1 SecWall: Interior Features BedRooms: 3 Electric: MX - MAXIMUM PrmlntWall: DW - Drywall FullBath: 1 HeatType: AvgHt/Fl: 1/213ath: 0 HeatFuel: - Prm.Flors: TZ - Terrazo %A/C: 0 %Heated: 0 %Sprinkled: 0 Special Features and Yard Items Land Information Type Y/S Qty. Units Qual. Cond. YrBlt- No. Land Use Type Measure Depth DWC - Driv-Concret Y 1 720 AV AV 1970 1 01 00-SF Res BI -Front Ft 60 134 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED http://www.paslc.org/prc.asp?prclid=240560104680002 4/26/2012 JOSEPH E. SMITH, CLERK OF THE CIRCUIT COURT - SAINT LUCIE COUNTY FILE # 3701942 Q, .00K 3387 PAGE 2291, Recorded' ;i/08/2012 at 02:40 t> I, ' Permit Number S442ed • Parcel ID Number yQ5 , 2 f: NOTICE OF COMMENCEMENT State of Flo ' ' 'County of yr.�_ The undersigned hereby gives notice that the improvements) will be made to certain real Property, and in accordance with Chaoter 713, Florida Statutes, the following information is provided in tills Notice of Commencement. .1. Description of grope (leg Addressal description of the pr ertg and sire t address 6 adaila6le) �� Ve y Legal Description_ 4 1 LA En k L t 2. General description of improvements) 3. Owner In crmatio Name 2 Address Phone & Fax Number ' Interest In pro a ("f 4• Fee Simpie Tltl Holder (If other than owner shown above) Name_ Address Phone & Fax Number S. Contractor Name Add res y�+/�!'i' P one&Fax Number 104 6. Surety (if any) NameN/A AddressN/A Phone & Fax Number 7. Lender (if any) i _-- NameNrA AddressNfA —' --- Phone & Fax Number ------------------- 8. Persons with the State of Florida designated by Owner upon who notices or other documents may be served as provided by 713.13(1) (a) 7, Florida Statutes, Name Addra �• ------ Phone & Fax Number 9. In addition to himself or herself, Owner designates the following to receive a copy of the Uenor's Notice as provided In 713.13(1) (b), Florida Statutes. Name Adore« _ _ Phone & Fax Number 10 Explrbtion date.of Notice of Commencement (the expiration date different date is.speciffed:' is'one year'from the'date of recording unless a WARNING TO OWNER: ANY, PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION- OF'THE •NOTICE OF- I COMMENCEMENT ARE CONSIDERED 'IMPROPER �•-9 PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13,.'FLORIDA STATUTES, AND CAN -RESULT IN YOUR PAYING � TWICE FOR IMPROVEMENTS TO YOUR PROPERTY:` A NOTICE. OF COMMENCEMENT Mu57'BE -RECORDED AND POSTED ON THE 108 SITE BEFORE THE FIRST INSPECTION. 08TAIN '. _ IFYOU TNTENOTO FINANCI G; CONSULT YO R. LENDER OR AN A RNEY BEFORE COMMENCING WORK OR RECORDING U NOTICE jl OF COMME1'E,-.'T),-nd i *.b.:Idl �� r/.Z. PrLrt.Name to before me this ; day Of _ 2p / NOIJ dr rat,Sworn v as (type of authority, e.g. officer, trustee, attomey in fact) for behalf of om� name of party. oh instrument 'was executed. _personally known to me or /_produced Yr as Identification. =M11-196 SSanv inlCoS ;seal) MYCO073388Name (PA l - — - EXP015 -AND-•m .. Veilfication pursuant to Section 92.525, Florida Statutes. Under penalties of perj ec are that I have readhe fooregolnRgnd. that the facts stated are true to the best of my knowledge and belief. \ , 7 /I STATE OF FLORIDA I Bu&lft & Mile RegutWon OMsI on 2Q Vnia Avmte Fort P1en�% I^t M8Z i Z -6443 I, ,T-,.,,� �ei � i`� �„ .� .....� iiE�lT 215 ��,i1�p!'�tfBCL�'�'�(�►'tS1C�iAi'C�$ f please pxinr & drele se 1t pe} *FMW ftWing tnspocWr *CMR9rO,lisakft& aEd�rsNr+►�rRAM;Cdna rarahybradcerC em�`n dar �s rn�Re ,,an on or about o tO Itv t0 0 f dW daffy Wpect the roj work at:__.m�'��#-i arc: (lab site addmss) Based,upon thn eye mi naclon t Have dete€rnk" the lansmil a don was done Accot dlog to tbft !#wecane Mmwon Retrat Aft (Based aril ssu" F.S.) S A"M Of FLOP) 7A as rsldenoaaitbn, aOrwho has produced Nawy PUNC. Rate of Fkx Simatum of NO - 0 l FSfDi� 7�a CUM in 01/29AOt1 � a OFFICE USE ONLY: DATE FILED: REVISION FEE: 2. 3. 4. 5. PERMIT # RECEIPT.' # PLANNING & DEVELOPM BUILDING & CODE REGUL 2300 VIRGINIA Al TORT PIERCE, FL 31 (772)462-1553 APPLICATION FOR BUILDINi PROJECT INFOIF LOCATION/SITE ADDRESS: © DETAILED DESCRIPTION OF PROJECT REVISIONS: �m CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: G C-c- 105 c3 �Z ST. LUCIE COUNTY CERT. #: BUSINESS NAME: p Q tt0 w\ 4-- 'p+ A+ QUALIFIERS NAME: ( v; rk,\ 6(.� S ADDRESS: 4 -7 y -S �,, ,' � , k. �, f CITY: ��e.e-fir u,c� STATE: FL PHONE (DAYTIME): 9 C (- 37 `(- IS., FAX- OWNER/BUILDER INFORMATION: NAME: ADDRESS: 1 3 9(5'7 n CITY: _ - `-4. t l �-e�- STATE: FL PHONE: FAX: ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: UITY: STATE: PHONE (DAYTIME): FAX: SLCCC: 9/23/09 Revised 04/26/2010 rvr ZIP: ZIP: 'Ge MIAMl-W', R DEPARTMENT OF PERMITTING, ENVIRONMENT, AND AFFAIRS (PERA) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) GAF Materials Corporation 1361 Alps Road Wayne, NJ 07470 MIAMI-DADE COUNTY PRODUCT CONTROL Ttis 10 .; ing issued under the applicable rules and regulations governing the use of construction mtt a1 he cumentation submitted has been reviewed and accepted by Miami —Dade County PERA — Prtduc'Control Section to be used in Miami —Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami —Dade County Product Control Section (In Miami —Dade County) and/or the AHJ (in areas other than Miami —Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction: PERA reserves the right to revoke this acceptance, if it is determined by Miami —Dade County Product Control Section that this product or material' fails to meet the requirements of the applicable building code.. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the Hi h Ve o e on a Building Code. DESCRIPTION: GAF Liberty"" SBS Self -Adhering Modified Bitumen Roofing Systems Over Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, and following statement: "Miami —Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use,.and/ or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded' by the words Miami —Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No. 09-0323.18 and consists of pages 1 thro gh 14. The submitted documentation was reviewed by_JozgaL. Ac,�y� __ _, T. LUCIE R �1.Id� r% . NOA No.: 11-1110.10 REVIEW Expiration Date: 02/22/13 DATE NS AND PERMIT Approval Date: 02/16/12 P JOB OR Page 1 of 14 pat1ST E KEPT ON NO INSPECTION WILL BE MADE L, ROOFING SYSTEM APPROVAL Category: Roofing Sub -Category: Modified Bitumen Deck Tyne: Wood Material: ' SBS Maximum Design Pressure: -60 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description Liberty"4 SBS Self -Adhering 39.375" x 66' ASTM D 6163 Self -adhered, SBS modified, Base/Ply Sheet fiberglass reinforced membrane for base or ply sheet applications. Liberty`'' MA Mechanically 39.375" x 66' ASTM D 4601 Mechanically attached, SBS modified, Attached Base Sheet Type.II fiberglass reinforced base sheet. Liberty'" SBS Self -Adhering 39.375" x 34' ASTM D 6162 Self -adhering, SBS modified, Cap Sheet - polyester / fiberglass composite reinforced cap sheet FireOut" Fire Barrier Coating N/A Proprietary Low VOC, water -based coating system that provides outstanding flame spread and penetration to combustible roof decks in the event of fire. RUBEROID® SBS Heat- 39.3.7" ASTM D 6164 Non -Woven Polyester mat coated Weld' Granule (1 meter) wide with polymer modified asphalt and, surfaced with mineral granules. RUBEROID® SBS Heat- 39.37" ASTM D 6164 Non -Woven Polyester mat coated Weld'M Smooth (1 meter) wide with polymer modified asphalt and smooth surfaced. RUBEROID® SBS Heat- 39.37" ASTM D 6164 Non -Woven Polyester mat coated Weld' 170 FR (1 meter) wide with fire retardant polymer modified asphalt and surfaced with mineral granules. RUBEROID® SBS Heat- 39.37" ASTM D 6164 Non -Woven Polyester mat coated Weld' Plus (1 meter) wide with polymer modified asphalt and surfaced with mineral granules. RUBEROID® SBS Heat -Weld 39.37" ASTM D 6164 Non -Woven Polyester mat coated Plus FR. (1 meter) wide with fire retardant polymer modified asphalt and surfaced with mineral granules. NOA No.: 11-1110.10 Expiration Date: 02/22/13 Approval Date: 02/16/12 Page 2 of 14 Test Product Product Dimensions Specification Description RUBEROID® SBS Heat- 39.37" ASTM D 6164 Non -Woven Polyester mat coated Welr 25 (1 meter) wide with polymer modified asphalt and smooth surfaced. Matrix' 307 Premium Asphalt 3, 5, 55 gallons ASTM D 41 Asphalt concrete primer used to Primer promote adhesion of asphalt in built- up roofing. Matrix 322 Elastomeric Roof 5, 55 gallons ASTM D 1653, Styrene acrylic -based roof coating Coating ASTM D 412, that forms a seamless and flexible ASTM E 470 layer of protection for your roof. ASTM D 6038 Matrix 602 MB Xtra 5, 55 gallons ASTM D 412, 'Surface coating for smooth surfaced Elastomeric Roofing ASTM B 117, and mineral surfaced roofs. Membrane ASTM C 794, ASTM G 21, FTMS 141.6271, ASTM D 21, ASTM D 1475 ASTM E 1644. Matrix 715 MB Elastomeric 5, 55 gallons ASTM D 412, Surface coating for smooth surfaced Roofing Membrane ASTM D 21, and mineral surfaced roofs. ASTM D 1475, ASTM E 1644 Topcoat® MB Plus 5, 55 gallons ASTM D 412, Water -based, low VOC, sprayable ASTM D 21, polymeric liquid, which cures to form ASTM D 1475, a seamless rubber membrane. ASTM E 1644 Topcoat® Surface Seal SB 5, 55 gallons ASTM D 412, Solvent -based, sprayable ASTM B 117, thermoplastic rubber liquid, which ASTM C 794, cures to form a seamless rubber ASTM G 21, membrane. FTMS 141.6271, ASTM D 21, ASTM D 1475, ASTM E 1644 GAFGLAS® FlexPly� 6 39.37" ASTM D 2178 Type VI asphalt impregnated glass (1 meter) wide felt with asphalt coating. GAFGLAS® Ply 4 39.37" ASTM D 2178 Type IV asphalt impregnated glass (1 meter) wide felt with asphalt coating. GAFGLAS® #75 Base Sheet 39.37" ASTM D 4601 Asphalt impregnated and coated glass (1 meter) wide mat base sheet. GAFGLAS® #80 UltimaTM 39.37" ASTM D 4601 Asphalt impregnated and coated, Base Sheet (1 meter) wide fiberglass base sheet. NOA No.: 11-1110.10 Expiration. Date: 02/22/13 Approval Date: 02/16/12 Page 3 of 14 Test Product Product Dimensions Specification Description GAFGLAS® Stratavent® 39.37" ASTM D 3672 Fiberglass base sheet coated on both Eliminator' Nailable (1 meter) wide ASTM D 4897 sides with asphalt. Surfaced on the ASTM D 4601 bottom side with mineral granules embedded in asphaltic coating. GAFGLAS® Mineral Surfaced 39.37" ASTM D 3909 Asphalt coated, glass fiber mat cap Cap Sheet (1 meter) Wide sheet surfaced with mineral granules. GAFGLAS® EnergyCapm 39.37" ASTM D 3909 Asphalt coated, glass fiber mat cap BUR Mineral Surfaced Cap (1 meter) Wide sheet surfaced with mineral granules Sheet and reflective EnergyCoteTm coating. RUBEROID® 20 39.37" ASTM D 6163 SBS modified asphalt base sheet (1 meter) wide ASTM D 5147 reinforce with a glass fiber mat. RUBEROID® Mop Smooth 39.37" ASTM D5147 Non -woven polyester mat coated with (1 meter) wide ASTM D6298 polymer modified asphalt. Does not have a factory applied surfacing. APPROVED INSULATIONS: TABLE 2 Product Name Product Description EnergyGuard7 PolyIso Polyisocyanurate foam insulation EnergyGuarr RA, EnergyGuard7 RN, Polyisocyanurate foam insulation EnergyGuarcr Ultra DensDecV DuraGuarr Modified Gypsum Roof Board Dens Deck®- Water-resistant gypsum board Securoc0' Fiber reinforced roof board Manufacturer (With Current NOA) GAF GAF Georgia-Pacific GAF USG Corporation NOA No.: 11-1110.10 Expiration Date: 02/22/13 Approval Date: 02/16/12 Page 4 of 14 APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. Drill-Tec�' #12 Standard Insulation fastener for Fastener: Various GAF Materials Corp. & Heavy Duty #14 steel, wood & concrete lengths Roofing Fasteners decks. 2. Drill-Tec'm ASAP® 3S Pre -assembled Fastener: Various GAF Materials Corp. fasteners and metal and lengths plastic plates. Plate: 3" diameter 3. Drill -Teem Plastic Round Polypropylene Plate: 3" & 3-'/z" GAF Materials Corp. Polypropylene Plates plate. diameter 4. Drill-Tec'T Metal Round galvalume Plate: 3" & 3-'h" GAF Materials Corp. Insulation Plates plate. diameter 5. Annular Ring Shank Galvanized steel Nail: Minimum Generic Nails & Tin Caps Ring shank roofing 12 Gauge (Dade County Approved) nails with Galvanized Various lengths steel tin caps. Tin Caps: Minimum 32 Ga 1%" Diameter EVIDENCE SUBMITTED: Test Agency/Identifier Name Report Date IRT-ARCON, Inc.. TAS 114 02-005 01/18/02 TAS 114 02-014 03/22/02 Factory Mutual Research Corp. 4470 3024805 11/20/06 Trinity I ERD ASTM D 6164 G6850.08.08 08/29/08 ASTM D 6222 G6850.11.08 11/05/08 ASTM D 6222 G6850.10.08 10/06/08 ASTM b 3909 G6850.08.07-1 08/13/07 ASTM D 3909 G30250.02.10 3 02/15/10 Exterior Research and Design, LLC TAS- 114 18035.12.02-2 12/24/02 ASTM D 5147 18034.03.03-2 04/23/03 TAS 114 01501.04.03 04/03/03 TAS 114 01516.04.06 04/20/06 TAS 114 G4280LAB.10.06 10/20/06 Atlantic & Caribbean Roof TAS 114 07-079 12/13/07 Consulting TAS 114 08-044 07/01/08 NOA No.: 11-1110.10 Expiration Date: 02/22/13 Approval Date: 02/16/12 Page 5 of 14 APPROVED ASSEMBLIES: Deck Type II: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank System Type A: Optional Fire Barrier over the deck. All layers of insulation are adhered to a mechanically attached anchor sheet. Membrane fully" or partially adhered. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Layer (Table 2) (Optional) Insulation Fasteners Fastener (Table 3) Density/ft2 EnergyGuai-C PolyIso, EnergyGuardT` RA, EnergyGuard 4 RN or EnergyGuardT' Ultra Minimum 1" thick N/A N/A Top Insulation Layer (Table 2) Insulation Fasteners Fastener (Table 3) Density/ft2 DensDecO or Securock"" Minimum 1/4"' thick N/A N/A Note: All layers of insulation shall be adhered to the anchor sheet in full mopping of approved hot .asphalt within the EVT range at a rate of 20-40 Ibs/100 sq. ft. or in 3/4" to 1" wide beads 6" o.c. of Olympic OlyBond5OOTm Adhesive or Olympic OlyBond Adhesive Fastener at a rate of 1 gal./100 W. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Fire Barrier: (Optional) VersaShieldo, Dens Deck® or Securoc0m. Anchor sheet: GAFGLAS® #80 ULTIMA� Base Sheet, GAFGLAS® # 75 Base Sheet, GAFGLAS® Ply 4 or GAFGLAS® F1exPly' 6, GAFGLAS® Stratavent® Eliminator Nailable Base Sheet, RUBEROID® 20 or RUBEROIDa Mop Smooth mechanically fastened to deck as described; Anchor sheet attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field. Ply Sheet: (Optional) One or more layers of Liberty'" SBS Self -Adhering Base/Ply Sheet, self -adhered. Membrane: One layer of Liberty"" SBS Self -Adhering Cap Sheet self -adhered or One or more layers of RUBEROID® SBS Heat -Weld' 25, RUBEROID® EnergyCap� SBS Heat Weld Plus, RUBEROID® SBS Heat -Weld"" Smooth, RUBEROID® SBS Heat -Weld' Granule, RUBEROID® SBS Heat -Weld"'` 170 FR, RUBEROID® SBS Heat -Weld``` Plus FR or RUBEROID® SBS Heat -Weld' Plus, applied according to manufacturer's application instructions. NOA No.: 11-1110.10 Expiration Date: 02/22/13 Approval Date: 02/16/12 Page 6 of 14 Surfacing: (Optional, required over RUBEROID® SBS Heat -Weld"" 25 or RUBEROIDID SBS Heat -Weld`"' Smooth) Install one of the following: 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. or applied in a flood coat of Leak Buster" Matrix 103 Cold Process Adhesive applied at a rate of 3 gal./sq. 2. GAFGLAS® Mineral Surfaced Cap. Sheet, GAFGLAS® EnergyCap"" Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. 3. Leak Buster Matrix"" 303 Premium Fibered Aluminum Roof Coating, at 1.5 gal./sq. 4. Leak Buster"" Matrix"" 715, Leak Buster" Matrix 322, TOPCOAT® MB Plus, TOPCOAT® Fireshield Elastomeric Roofing Membrane, applied at 1 to 1.5 gal./sq. 5. Leak BusterT' Matrix"" 662 MB Xtra Elastomeric Roofing Membrane, EnergyCote"" roof coating applied at 1 to 1.5 gal./sq. 6. TOPCOAT® Surface Seal SB, TOPCOAT® Fireshiele SB Solvent based 'Elastomeric Roofing Membrane applied at Ito 1.5 gal./sq. Maximum Design Pressure: -45 psf (See General Limitation 47) NOA No.: 11-1110.10 Expiration Date: 02/22/13 Approval Date: 02/16/12 Page 7 of 14 Deck Type 1I: Wood, Insulated Deck Description: Min. 15/32" plywood to supports max. 24" o.c. with 8d common nails max. 6" o.c. System Type C(1): Optional Fire Barrier over the deck. Top layer of insulation is simultaneously mechanically attached with optional layer of base insulation to the deck. Membrane fully or partially adhered. All General and System Limitations apply. Fire Barrier: (Optional) VersaShiele, Dens Deck® or-SecurocOm. One or more layers of any of the following insulations. Base Insulation Layer (Optional) (Table 2) Insulation Fasteners Fastener (Table 3) Density/fe Any approved rigid board insulation (EnergyGuardTm PolyIso, EnergyGuardT'" RA, EnergyGuardTM RN or EnergyGuardT" Ultra) (Loose laid) N/A N/A Top Insulation Layer (Table 2) Insulation Fasteners Fastener (Table 3) Density/ft2 EnergyGuarC PolyIso Minimum 1.5" thick 1 & 4 1:2 Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density., Please refer to -Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: Liberty"'' SBS Self -Adhering Base/Ply Sheet. Ply Sheet: (Optional) One or more layers of LibertyTM SBS Self -Adhering Base/Ply Sheet, self - adhered. Membrane: One layer of LibertyT`" SBS Self -Adhering Cap Sheet self -adhered or One or more layers of RUBEROID® SBS Heat-WeIC 25, RUBEROID® EnergyCapTM SBS Heat Weld Plus, RUBEROID® SBS Heat -Weld? Smooth, RUBEROID® SBS Heat-Wele Granule, RUBEROID® SBS Heat WelP 170 FR, RUBEROID® SBS Heat-Wele Plus FR or RUBEROID® SBS Heat-WeldTM Plus, applied according to manufacturer's application instructions. APPROVED:''j'` NOA No.: 11-1110.10 Expiration Date: 02/22/13 Approval Date: 02/16/12 Page 8 of 14 �1 1 Surfacing: (Optional, required over RUBEROID® SBS Heat-WeIC 25 or RUBEROID® SBS Heat -Weld"'' Smooth) Install one of the following: 1. Gravel or slag applied at 400 lbs./sq. and 3001bs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. or applied in a flood coat of Leak Buster"' MatrO 103 Cold Process Adhesive applied at a rate of 3 gal./sq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® EnergyCapT" Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. 3. Leak Buster' Matrix 303 Premium Fibered Aluminum Roof Coating, at 1.5 gal./sq. 4. Leak Buster' Matrix 715, Leak Buster'' Matrix 322, TOPCOAT® MB Plus, TOPCOAT® Fireshield Elastomeric Roofing Membrane, applied at 1 to 1.5 gal./sq. 5. Leak Buster' Matrix 602 MB Xtra Elastomeric Roofing Membrane, EnergyCote"4 roof coating applied at 1 to 1.5 gal./sq. 6. TOPCOAT® Surface Seal SB, TOPCOAT® Fireshiele SB Solvent based Elastomeric Roofing Membrane applied at lto 1.5 gal./sq. Maximum Design Pressure: -45 psf (See General Limitation # 7) S�1APPROVED' NOA No.: 11-1110.10 Expiration Date: 02/22/13 Approval Date: 02/16/12 Page 9 of 14 r Deck Type 1I: Wood, Insulated Deck Description: Min. 15/32" plywood to supports max. 24" o.c. with 8d common nails max. 6" o.c. System Type C(2): Optional Fire Barrier over the deck. Top layer of insulation is simultaneously mechanically attached with optional layer of base insulation to the deck. Membrane fully or partially adhered. All General and System Limitations apply. Fire Barrier: (Optional) VersaShieldo,.Deris Deck® or Securock7. One or more layers of any of the following insulations. Base Insulation Layer (Optional) (Table 2) Insulation Fasteners Fastener (Table 3) Density/fe Any approved rigid board insulation (EnergyGuard7M Polylso, EnergyGuard"' RA, EnergyGuard' RN or EnergyGuard' Ultra) (Loose laid) N/A N/A Top Insulation Layer (Table 2) Insulation Fasteners Fastener (Table 3) Density/ft2 DensDecko DuraGuard"" Minimum 1/2" thick 1 & 4 1:2 Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: Liberty". SBS Self -Adhering Base/Ply Sheet. Ply Sheet: (Optional) One or more layers of Liberty'' SBS Self -Adhering Base/Ply Sheet, self - adhered. Membrane: One layer of Liberty' SBS Self -Adhering Cap Sheet self -adhered or One or more layers of RUBEROID® SBS Heat -Weld' 25, RUBEROID® EnergyCap"' SBS Heat Weld Plus, RUBEROID® SBS Heat -Weld' Smooth, RUBEROID® SBS Heat -Weld''' Granule, RUBEROID® SBS Heat -Weld' 170 FR, RUBEROIDO SBS Heat -Weld"`` Plus FR or RUBEROID® SBS Heat -Weld` Plus, applied according to manufacturer's application instructions. NOA No.: 11-1110.10 Expiration Date: 02/22/13 Approval Date: 02/16/12 Page 10 of 14 Surfacing: (Optional, required over RUBEROID® SBS Heat -Weld? 25 or RUBEROID® SBS Heat -Weld? Smooth) Install one of the following: 1. Gravel or slag applied at 4001bs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. or applied in a flood coat of Leak Buster ` Matrix"M 103 Cold Process Adhesive applied at a rate of 3 gal./sq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® EnergyCapTm Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. 3. Leak Buster' Matrix ` 303 Premium Fibered Aluminum Roof Coating, at 1.5 gal./sq. 4. Leak Buster' Matrix 715, Leak Buster"4 Matrix M 322, TOPCOAT® MB Plus, TOPCOAT® Fireshield Elastomeric Roofing Membrane, applied at 1 to 1.5 gal./sq. 5. Leak Buster' Matrix 602 MB Xtra Elastomeric Roofing Membrane, EnergyCote"m roof coating applied at 1 to 1.5 gal./sq. 6. TOPCOAT® Surface Seal SB, TOPCOAT® Fireshiele SB Solvent based Elastomeric Roofing Membrane applied at Ito 1.5 gal./sq. Maximum Design Pressure: -52.5 psf (See General Limitation # 7) NOA No.: 11-1110.10 Expiration Date: 02/22/13 Approval Date: 02/16/12 Page 11 of 14 Deck Type 1: Wood, Non -insulated Deck Description: Min. L5/32" plywood to supports max. 24" o.c. with 8d common nails max. 6" o.c. System Type E(1): Optional Fire Barrier over the deck. Base Sheet is mechanically attached to the deck. Membrane fully or partially adhered. All General and System Limitations shall apply. Fire Barrier: (Optional) VersaShieldo, Dens Deck® or Securock7". Base Sheet: LibertyTM MA Mechanically Attached Base Sheet. Fastening Options: Base sheet is mechanically attached to the deck with Drill-Tec"4 #14 Fasteners and Drill-TeCT" 3" Galvalume Plates, 8" o.c. in the 3" laps and 8" o.c. in two staggered rows in the field. (Maximum Design Pressure —60 psf,_&e_Gen raUJu.t lion heet-is-m-chanic�ttached to the deck with FBC HVHZ tin -caps and nails .c. in the 3" laps and 8" o.c. in three equally spaced, staggered rows in the f the sheet. Cat mum Design Pressure —45 psf, See Genera[ Limitation #7) Ply Sheet: (Option a or more layers of Liberty SB e - ermg ase y Sheet. Cap Sheet: One layer of Liberty SBS Self -Adhering Cap Sheet self adhered or One or more layers of RUBEROID® SBS Heat -Weldor 25, RUBEROID®EnergyCap"m SBS Heat Weld Plus, RUBEROID® SBS Heat -Weld' Smooth, RUBEROID® SBS Heat -Weld' Granule, RUBEROID® SBS Heat -Weld' 170 FR, RUBEROID® SBS Heat -Weld` Plus FR or RUBEROID® SBS Heat -Weld' Plus, applied according to manufacturer's application instructions. Surfacing: (Optional, required over RUBEROID® SBS Heat -Weld"'' 25 or RUBEROID® SBS Heat -Weld'" Smooth) Install one of the following: 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. or applied in a flood coat of Leak Buster'`' Matrix'' 103 Cold Process Adhesive applied at a rate of 3 gal./sq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® EnergyCap'" Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-401bs./sq. 3. Leak Buster' Matrix 303 Premium Fibered Aluminum Roof Coating, at 1.5 gal./sq. 4. Leak Buster"'' Matrix 715, Leak Buster'" Matrix 322, TOPCOAT® MB Plus, TOPCOAT® Fireshield Elastomeric Roofing Membrane, applied at 1 to 1.5 gal./sq. 5. Leak Buster` Matrix 602 MB Xtra Elastomeric Roofing Membrane, EnergyCote'" roof coating applied at 1 to 1.5 gal./sq. 6. TOPCOAT® Surface Seal SB, TOPCOAT® Fireshieie SB Solvent based Elastomeric Roofing Membrane applied at lto 1.5 gal./sq. Maximum Design Pressure: See fastening options above '<�_� _ :.APPROVED: �•�_,�a. ��� AA NOA No.: 11-1110.10 Expiration Date: 02/22/13 Approval Date: 02/16/12 Page 12 of 14 Deck Type 1: Wood, Non -insulated Deck Description: Min. "/32" CDX plywood nailed to 6" o.c. at the field of the sheet with #8 ring shank nails and 4" o.c. at the perimeter of the sheet with #10 ring shank nails. Plywood installed over wood rafters spaced 24" o.c. System Type E(2): Optional Fire Barrier over the deck. Base Sheet is mechanically attached to the deck. Membrane fully or partially adhered. All General and System Limitations shall apply. Fire Barrier: (Optional) VersaShieldo, Dens Deck® or Securock7. Base Sheet: GAF StormSafeTM base sheet fastened to the plywood deck using Drill -Tee.. Standard #12 screws and 3" Drill-TecT`" Accutrac Flat bottom plates or Drill-Tec"4 AccuTrac Plate spaced 9"o.c. at the 4" side laps and 3 rows spaced 9"o.c. in the field of the sheet. Ply Sheet: (Optional) One or more layers of Liberty7. SBS Self -Adhering Base/Ply Sheet. Cap Sheet: One or more layers of Liberty SBS Self -Adhering Cap Sheet self adhered. Seams sealed by applying TOPCOAT®SB900 or Flexseal. Surfacing: (Optional) Install one of the following: 1. Gravel or slag applied at 400 lbs./sq. and 300 ,lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. or applied in a flood coat of Leak Buster Matrix 103 Cold Process Adhesive applied at a rate of 3 gal./sq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® EnergyCapTM Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. 3. Leak BusterT Matrix 303 Premium Fibered Aluminum Roof Coating, at 1.5 gal./sq. 4. Leak BusterT MatrixTM 715, Leak BusterTM Matrix . 322, TOPCOAT® MB Plus, TOPCOAT® Fireshield Elastomeric Roofing Membrane, applied at 1 to 1.5 gal./sq. 5. Leak Buster Matrix 602 MB Xtra Elastomerie Roofing Membrane, EnergyCoteTM roof coating applied at 1 to 1.5 gal./sq. 6. TOPCOAT® Surface Seal SB, TOPCOAT® Fireshiele SB Solvent based Elastomeric Roofing Membrane applied at lto 1.5 gal./sq. Maximum Design -Pressure: -60 psf (See General Limitation # 7) AP.P.flOVED'.., xv: NOA No.: 11-1110.10 Expiration Date: 02/22/13 Approval Date: 02/16/12 Page 13 of 14 WOOD DECK SYSTEM LIMITATIONS: 1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. GENERAL LIMITATIONS: I. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product: 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-401bs./sq., or mechanically attached,using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 2751bf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchoribase sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised'fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform with Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10 All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 11-1110.10 Expiration Date: 02/22/13 Approval Date: 02/16/12 Page 14 of 14 LIBERTY SELF -ADHERING FLAT ROOF o APPLICATION SYSTEM (NOA 11-1110.10) z 1/12 ROOF SLOPE (EXISTING). W Z w U LIBERTY BASE SHEET (MECH. FASTEN -- SEE SCHEDULE)Oi O � 1 LAYER LIBERTY SELF -ADHERING PLY SHEET F+ a Q a LIBERTY SELF -ADHERING CAP SHEET pM 0 4.4 EXISTING 518" PLYWOOD SHEATHING N �P M M U w BASE SHEET FASTENING SCHEDULE FASTENER: HVHZ tin caps & nails U FIELD: 8" OC @ LAP (3" LAPS), 3 ROWS @ 8" OC A W 0 p�A EDGE: 4" OC @ LAP, 4 ROWS @ 4" OC H (REFERENCE: RAS 117 d CORNER: 4" OC @ LAP, 4 ROWS @ 4" OC DESIGN PRESSURES FROM FBC2010, CH 16 (Vult =160 mph) FIELD: -44.9 psf ROOF HEIGHT = 12 ft .•' A; BL �•• Lildon Engineering Company, Inc. yC:•• ''•� •• 920 Sunset Shores Dr. ENS PERIMETER: -69.0 psf �,\GF ' Mineola, Florida 34715 ' No 52583 CORNER: -96.3 psf ■ 2) -2590 Ph. &FAX STATE OF • ,o o R�pPC ; •••SwONA�� • ay 21, 2012 Wayne A Block, PE#52583 i aim WINOOW DIAGRAM SHEET . . . . . . . . . . : : , - - - , . . . . " , , . . . . . . I P k 4 * . . '0" #. 1 • P CL IT cm ZQ !( a > 1 • • } +�� • t . • • iii • a } ■ • 1 ! i r • 1 r r r r. • J p a ' . ' I • • • . • a . • • > ♦ r • yI a i J ♦ [j • > } ° • • f . • • t . a • • > • • > • . ♦ a I • e • • a \ • • r . • • • • : w ..i,. ` P 1 J . r . • a i J`(■1 r/rl,�r], • . • ` • a r • J • . • J . , * . • a a . > . s 1 a . ill � • • { r • > a �� � • • r a a � ■ a / . � • •.•a ` f . . Ji , • y, { a S r A +1•� • • 1 a • • • > ( r { . . . . t 1 / a • a LULIj ... > ( ■ � X Akan Roof ldetght � > Mean Roof Height Ballding Width > Roorstope �-02•t�5 S�'G•f� _ BalJding Length THD AT -HOME -SERVICES PRE -INSTALLATION INSPECTION,,"_'.�:ET CUSTOMER NAME Noble PROJECT MANAGER JOE P. �. ADDRESS 3807 Ave N DATE 4/3/2012 AT-HOME CITY Fort Pierce DAY / WORK PHONE JOB # 6170498 EVENING / HOME PHONE DRAWING: INDICATE ACCESS, WATER, POWER SEPTIC TANK, EXPOSED ROOF SECTIONS PITCH ROOF . . . . . . . . . EXISTING ................................................SQUARES 13 ...............................................INSTALLING .................. ............... �SC�GSGtt FLAT ROOF .........................................EXISTING ................................................SQUARES 8 ................................................INSTALLING ................................................ . . . . . . . . . . . . . . . . . . . . . . . . . . . . NO OF STORIES 1 ................................................ROOF HEIGHT AMOUNT MATERIALS PITCH ROOF 1 1/2" LEAD FLAT ROOF ROOF SLOPE 3/12 DECK HEIGHT 1.5/12 2" LEAD RIDGE HEIGHT 14' PARAPET HT 3" LEAD EAVE HEIGHT 8' TOTAL HEIGHT 1 4" LEAD MEAN HEIGHT 10' Gooseneck - 4" FLASHINGS —TYPE Gooseneck - 6" EXTRA ROOF LAYERS 1 Gooseneck - 10" ACCESS EASY RIDGE VENT /TYPE &SIZE TURBINES N REUSE/REPLACE/REMOVE DECKING SIZE / TYPE SKYLIGHTS N REUSE/REPLACE/REMOVE FASCIA SIZE /TYPE SCREEN ENCLOSURE N RAFTER SIZE / TYPE ATTIC FANS N FURRING STRIP SOLAR HEATERS N DRIP FT 2X / TYPE A/C UNIT - N DRIP FT 3X / TYPE 4X5 L-FLASHING SOFFIT VENTING INFORMATION SPECIAL FLASHING TYPE SIZE INSULATION OVERHANG SIZE CANT STRIP ROOF TYPE: GABLE JOB OK AS IS: YES :JOB ON HOLD: EXISTING DAMAGE TO: INTERIOR EXTERIOR CEILINGS DRIVEWAY N N ------------------- ------ Y ----------------------------------------- WALLS N -------------------------------------------------- ---------------------------N WALKWAY N FLOORS------------------------------------------------------------------------------------------- ----------------------------------------------------------------LANDSCAPE--- N LIGHT FIXTURES N GUTTERS N -------------------------- ------------------------------------------------------------------------- DOORS N ------------------------------------------- FURNITURE-----------N--------------------------------- —WINDOWW S N WALLS ---------------------------------------------------------- SPECIAL INSTRUCTION: �ME DEPOT AT HOME SER`�_ ''ES Vendor: Location: Material Purchase Order 674 S. Military Trail Deerfield Beach, Florida 33442 phone 954-379-1560 Bradco Deliver To: Name: Phone No Address: City: State: Zip: Directions: Noble 77 :.2 4,6.0, 6070 3807 Ave N Fort Pierce FL 34947 TRUCK TYPE: BOOM XX,RANE P.O. # 6170498 Order Date: 4/3/2012 Delivery Date: Job Number: 6170498 Work Designated Stage Area: ROOF PIGGYBACK 13 SQ. ATLAS GLASSMASTER 25 - Oyster Shell 2r BNDL PRO -CUT HIP & RIDGE BNDL PRO -CUT STARTER ...,RL Weather Watch (Storm Guard) 10 PC Cobra II Ridge Vent- 1 RL Membrane 6" 1 PL Bull 30 lb Felt 13 RL x24= PC 3X3 Drip Edge *** White *** :t 1' RL 16" flashing (valley metal) 50ft k PC 1 1/2 " Lead Jack PC 2" Lead Jack 1 ' PC 10" Gooseneck 1 _ PC 4" Lead Jack 3 RL 75 lb Felt (Miami) 4 RL Polyglass underlayment 8 RL Polyglass Cap for Flat (FR) 1 can Asphalt Primer Requested By: Joe P. Date Requested: Approved By: Date Approved: TOTAL $ _ 4/3/2012 MIAMI.: Im BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION Atlas Roofing Corporation 2000 Riverside Pkwy Atlanta, GA. 30328 r 1 �J MIAMI-DADE COUNTY, FLORIDA METRO -)JADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130-1553 (305) 375-2901 FAX (305) 375-2908 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use, of construction materials: The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (in Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing -and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BOR4 reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control. Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane zone of the Florida Building Code. TION: G1assMast------------- er LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA 405-020I ,09 and consists of pages I through 4. The submitted documentation was reviewed by Alex Tigera. NOA No.: 09-0114,01"- MIAiM bDADE COUNTY Expiration Date: 04/22/14 Approval Date: 03/11/09 . Page 1 of 4 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -category: 07310 Asphalt Shingles Material: 3-Tab I. SCOPE This approves. G1assMater 25 manufactured by Atlas Roofing Corp. described in Section" 2 of this Notice of Acceptance, designed to comply with Florida Building Code,, High Velocity Hurricane Zone, 2. PRODYJCT DESCRIPTION Product Dimensions Test Specifications Product Description GalssMater 25 12" x 36" TAS 110 A heavyweight, fiberglass reinforced. Three tab asphalt shingle. 3. EVIDENCE SUBMITTED Test Aeencv Test identifier Test Name/Report Date PRI Asphalt TAS 100 Wind driven rain. 07/09/03 Technologies. Underwriters TAS 107 02NK6989 03/04/02 Laboratories, Inc. Underwriters ASTM 3462 Physical Properties 09/17/02 Laboratories, Inc. 4. LIMITATIONS 4.1 Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. - .2 Shall not be installed on roof mean heights in excess of 33 ft. 5. INSTALLATION 5.1 Shingles shall be installed in accordance with Roofing Application Standard RAS 115. 5.2 Flashings shall be in accordance with -Roofing Application Standard RAS l 15. 5.3 The manufacturer shall provide clearly written application instructions. 5.4 Exposure and course layout shall be in compliance with Detail 'A', attached. 5.5 Nailing shall be in compliance with Detail'B', attached. 6. LABELING 6.1 Shingles shall be labeled with the Miami -Dade Product Control Approved Sea] or the wording "Miami -Dade County Product Control Approved". MIAMI-DADS COUtITY CMIAMEADE COUNTY NOA No.: 09-0114.01 Expiration Date: 002/14 Approval Date: 03/11/09 Page 2 of 4 7. BUILDING PERMIT REQUIREMENTS 7.1 Application for building permit. shall be accompanied by copies of the following: 7.1.1 This Notice of Acceptance. 7.1.2 Any other documents required by the Building Official or the applicable Building. Code in order to properly evaluate the installation of this system. DETAIL "A" "GSSM&STER 25" Start let aararee Wilt iull'&Nrds _. .. Qrip-eckge- Starter Strip NOA No.: 09-0114.01 Expiration Date: 04/22/14 Approval Date: 03/11/09 Page 3 of 4 DETAIL "B" END OF THIS ACCEPTANCE MIAMI•DADE COUNTY NOA No.: 09-0114.01 o ► Expiration Date: 04/22/14 Approval Date. 03/11/09 Page 4 of 4 #3 ROOFING MATERIALS AND SYSTEMS DiREo. ;lY 2 ROOF COVERING MATERIALS (TEVT) Prepared Roof Covering Materials ('TFWZ)—Continued be activated by solar heat of intensity Senerally attained on warm, sunny days. Other shingle's with factory -applied adhesive utilize a' combination pressure-sensitive'and heat -sensitive adhesive. Due to the nature of"adhe- sives of this type, sealing is induced by application of pressure and/or heat. Hip. and Ridge Shingles are composed, of asphalt or modified asphalt - coated glass -fiber mat surfaced •wish granules and are intended to be, installed as specified on packaging supflied with the product for hip and ridge installations only. They are investigated for fire resistance in accor- dance with Subject 2375, "Outline of Investigation for Hip and Ridge Shingldg." Where indicated, they have also bebn investigated for wind resis- tance at velocities up• to 110 mph: Wind -resistant hip 4' id ridge shingles may utilize'Iocking'mechanisms, field -applied adhesives"or factory -applied heat -sensitive adhesive which must be activated by's•'olar'heat bf intensity generally;affaw6d on warm, sunny days. ' RELATED PRODUCTS Prepared roof covering materials investigated for impact resistance are covered Vndrs Roof Covering Materials, Impact Resistance (TGAM ). Asphalt'shingke investigated'fdr wind resistance are covered under Pre- pared Root Cdveiiq Material's, AsphaIt Shingle Wind=Resistance (TGAH ). Accessoiy'cd*bnedts titilized in the preparedd ib6f{covering system are covered -under P46red Roofing Accessories` (TGDY ).- Ridge 'vents utilized in the prepared roof covering system are covered under Rldge'Vehts' (TGEW ). Type 15 aria Type 30 asphalt felts, uged'as underla ents; are covered. under Roofing: Systems (TGFU ). Underlayiirents, nd�gge'vents and accessory compbnerits,'when utilized, are inteirdt d't6 be"Classified materials, ADDITIONAL -INFORMATION' For additional information, see Roof Covering Materials (TEVT) and Roofing Materials and Systems (AARivI REQULItEA4ENTS' • The basic standafds used to JhVestigate pidducts iri this'category are ANSI/UL 790,'•'Test's for Fire Resistance of Roof C6veang Materials" (ASTA E#68-and ANSI/NFPA 256 ), and UL 997, "Wind Resistance of Pre- pareH Roof'Goveridg Material's" (ASTM D3162'): ; : UL-MARK- The Listingg.Ivfar% of Underwriters Laboratories Inc. on the product is the only'method'Rovided•by UL to identify proddcts'manufactirred tinder its Listingg and PolloW-Up Service: The Listingg'M' k'for 'these pioducts' iricIydes`th'e LIL'symbol (as ill6strated in the.Irftioductiori "of"this Directory) together With'the ivora "'LISTED," and the foll&Wing additional information: PREPARED ROOF COVERlN•G MATERIAIS - • ` DEGREE OF -RESISTANCE TO"EXTERNAL }IRE =CLASS + issue 0. ' The Listing Mark maq also include one or more 'of the fo116i4g state- " rn n'*;as apprdpp'nate: `DEGRE_E, 61' VDb RE 18YAINCE IN •ACCOitf7ANCE WITH UL 997 WIND RESISTANCE HAS'MSO BEE9_IW1&IGATED AT WIND - .; ,, . _• VELOCITIES UP FO ++IYIi?I4 ' �YIND 12ESISTAIVCg• '• .' '. • ` :.. : ALSb Ci.AS'SIFIEEON ACCORDANCE 4VII`F1 t1STi�3'D31b1, CLASS +++ 'At` 6' CLASSIFIED IN ACCORDANCE ` ftlT ASTM D3462 A StS'Ct"gill;EDllgACCOIIDANCLt'tiVITIi'CANICSA-A123.5 +A,BorC ++ Specific'maximum Wind velocity used in tyre investigation ::'^•, r ATLAS ROOFING CORP . It4052 SUifE'800'2000 I - I.. 6D ,kPKY,ATLANTQ•GA30328 Asphalt orgranfc felt sheet roo nrenaiad inn ,• fine and shingles; for installation as Class C Asphalt - glass .iijz}'.shingles, fore insfaiaHon: as Class A :prepared ,r6bf coverings. Suitable for, fast ation 9verp3%8 i}t. and 1/2 in; pl} 's<400d decks.. Asphalf organic'fgl}:shingles and ashalt.glass ritaf shinglle, tion as wind resistant roof coverings. for ingtaTla= _ Asplialt,.glass fitsei What shirigIes; • foi .16tallation• as wind -resistant roof coverings; May :also bear:the follRyimg statement "also evaltrated'at Velocities up to 110 mph". ]Vodified,asphalt glass fiber mat s deckhingles, for installation as Class A preps. ared roof coverings for installation on minimum 15/32 in, chick plywood Ivfodified asphalt, glass fiber mat shingles, foi irisfallatioii as wind resistant root coverings. Three tab••and laminated shingles may bear the stafeirient, "Also evaluated ai wind velocities up to 110 mph" , 114odified,,asphalt glass fiber sheet roll roofing for installation as Class C prepared coo.coverings. BUILDING PRODUCTS OF CANADA CORP R14399 9510 St PATRiCK•ST, LASALLE, QC H8R 1R9 CANADA. Asphalt.•glass ,mat shingles, for installation as Class A prepared roof coverings Suitable for installation over 3/8 in. min. plywood decks; iMay also bear the following statement "Also Classified in Accordance with ASTM D3161, Class D-or R ROOF COVERING MATERIALS (TEVT) Prepared Roof Covering Materials (TFWZ)—Continued Asphalt organic felt shingles, for installation as Class C prepared roof coverings, Srrhtable for installatidri over•3/8 in.'min, plyivgod decks. Asphalt organic'felt shingles and:asphdt glass mat shingles, .tor installa- tion as wind resistant roof coveringgs: May also bear the following statement "Also Classified in Accordance ivitf ASTM D3161; Class D'br-P. " CANROOF CORP INC R2459 560 COMMISSIONERS ST, TORONTO, ON114ti4•IA7 CANADA Asphalt organic -felt 'sheet roofing and slilriiles, fof'fnstallatiori a's'Clas4 C prepared roof coverings. Asphalt orgaruc-felt shingles, for installation as wind resistant roof covehi gs, Asphalt mineral wool=fe1t'shingles for insta)ation as Class A prepared roof •covering's. Asphalt min fat ivoiil'felt shingles, for installation as wind resistant roof coverings; . CERTAINTEED CORP = R684 ROOFING PRODUCTS GROUP 1400 UNIOI�I`h2EE'T N' RIJ PO ' BOX•ifk, BLUE 'BEU PA i9422 '' " .. ' Asphalt glass mat shingles,, for, installation as Class pprepared roof coverings. Suitable for fwtallaQi rl on mirfttini 3/8 in: thic�plywood decks. Asphalt glass mat and hip and .ridge shingles, for installation as wind resistant roof, coverings. Windpresistance has also been evaluated in accordance with ASTMM D316#, Claw: p and R Wind re isiance for "Presidential Accessory, Oxfords ] fatteras Accessory,, Siiang7e 7tfdge and Shadow Ridge, hie ,6E ridge shingles have als6 beerl evaluated in,accoidagce with ASTM IJ31,61, C1ass.P whisk BASV Sorjr4olastic AIS % a,¢liesi e p,t Kinkel PLO Polyurethane Roof 4 FIastiing Sealant, applied al; specified in niGdacturer' apphcation.ipst;ric- AsgIialt;glass mah'shingles,.Classified in accordance with'Abim D3�62r inclyding tear resisance...;; •,,. `. i Aspha f.,glass, ivat .shingles, for -irist4l Oon as, Mass . prepared: hoof coygripgs : Asphalt organic felt shingles, for .installation as Class C,prepared 'roof Asphalt organic felt; shingles, f6r, installation as.iyind resistant roof cet- Asph£lt 'glass fiber neat, shingles,. Classified ,in •accordance with CAN/CSA123.5-M90. • '.' WdhRed a'sphaft glass fiber mat shingles, foi:installation as:Class A prepared• roof coverings. Suitable- for installation alinirnurn �/8 in. thick plywood:decks.=Mgdified"asphalt glass, fiber mat shingles, for,installaEion.as iiind resisfant roof coverings: , ,. Asphalt glass mat shingles, for• iis*lallation.as C1ass.'t�:tpiepared r6of covering when used with minfrnum.Type 30 underlayment Ever existing wood shingle roof. ELK CORP :: ;, 93915 .. SIJiTE 66014911 QUORUM DR, DALLAS TX 752S4 Asphalt• glass mat shingles,, for installation as .Class A prepared roof covRl tgs, Suitable for .iustallation on minimum 3/8 in.thick •plywood ljecks. Asphalt glass mat shingles, for installation as tviAd-resistant•roof coyerings. Wind resistance has also been evaluated at tvfnd•velbcltfes up to 110 mph. Asphalt.glass mat, shingles Prestfque Plr s,•.for installation as Class A prepared roof covering when used over existing wood.sh gl�rogf, Asphalt glass niat shrrrgles, Prestique I and Prestique T1, for insiallathon as CIass A prepared roof coyering when used ,with mirdmum.'fype 15 underiayr meat over existing wood shingle roof. halt glass mat shingles, Classified in acco;dance Ivith Standard AST'M Q Modified asphalt glass fiber mat shing•1es,,for installation, as Class A prepared roof coverings. Suitable for installatioin. ri,on $/8,thick =plytivoga d GAF sMATERIALS CORP • , R21 1361 ALPS. RD, WAYNE Nf 0147¢ Asphalt organic/glass fiber mat shingles and sheet roofing, for. installation as Class C•preparedroof,coverings, ;. ;,,.: Asphalt organic/glass fiber mat shingles for installation as wind resistant roof coverings. Asphalt glass fiber mat shingles, for installation es,C(ass A roof:coyeringc Suitable for installation on minimum 3/8.iniljdd<.pply.vood, "Slateline".as halt glass fiber prat shingles; f0tdnstagation as Class;A roof covering: Suitable for installation on •15/324n, •thick.plywoQd in combination with minimum one ply "Shingle -Mate" or Type 15 or Type 30 underlayment Asphalt glass fiber mat shingles,.for installation as wind resistant roof coverings. .. • : • . : •. Asphalt glass fiber mat sheet-ro4ng, for installation as Class C prepared roof covering.... . .. s:. : •u! 1 Asphalt -glass mat slrin8les,-for installation as wind resistant roof coverings. Asphalf: glass. mat shingles, for installation as Class A prepared roof covering when used with minimum Type 30 underlayment over existing wood shingle roof, LOOK FOR THE UL MARK ON PRODUCT GlassMaster feral Instructions - Ardmore, OK & Ha,;,r,:on, GA A7 Atlas Roofing ROOFFAINr.oG GlassMaster® General Instructions - Ardmore, OK & Hampton, GA For Spanish Instructions Cilick Here (Para gas Instrucciones Escaeiollas Haga Clic Aqu() (For Metric Size Franklin OH Instructions Click Here) IMPORTANT: THE STATEMENTS EXPRESSED ON THIS WRAPPER ARE THE RECOMMENDATIONS FOR THE APPLICATION OF THE ROOFING PRODUCTS AS OUTLINED AND ILLUSTRATED. ANY DEVIATION FROM THESE RECOMMENDED PROCEDURES SHALL BE AT THE SOLE RISK OF THE INSTALLERS. FAILURE TO FOLLOW THESE INSTRUCTIONS MAYRESULT IN SERIOUS DAMAGE TO THE APPLICATION AND LIFE OF THIS ROOFING PRODUCT, RESULTING IN THE TERMINATION OF ANY WARRANTY, EXPRESS OR IMPLIED. 1. GENERAL INSTRUCTIONS These shingles are warranted against manufacturing defects and wind gusts up to 60 MPH. A copy of the GlassMaster® 25 Limited Warranty is available from your supplier, or applicator, or by writing to: Atlas Roofing Corporation, Attn: Consumer Service Department, 2564 Valley Road, Meridian, Mississippi, 39307. The following instructions must be followed to qualify for protection under the GlassMaster® 25 Limited Warranty. Important: Do not apply GlassMaster® 25 shingles on roofs having a slope less than 2" per ft. See special in for Low Slopes (2" to 4" per ft.) and for Steep Slope/Mansard/High Wind application. To obtain stated area coverage and to achieve design performance and appearance, the directions on this package must be followed. Sealing of the adhesive strips on each shingle to the shingle beneath is created by heat from sunlight. Sealing may be delayed if shingles are applied during cooler temperatures, or to roof areas that do not receive direct sunlight. Dust accumulation may also further delay sealing. If any of the strips have not activated properly after a reasonable time period, hand sealing may be necessary. Shingles in prolonged -storage rray-pick up temporary staining, which is removed by natural weathering. Double stacking can cause staining and sticking in the bundle. Atlas Roofing Corporation also endorses the Asphalt Roofing Manufacturers Association's (ARMA) recommendations for application details not specified on this wrapper. 2. ROOF DECK VENTILATION Adequate ventilation under the roof deck must be provided to prevent harmful condensation in winter and heat build-up in summer. These conditions can cause: A.) Accelerated roof weathering B.) Deck rot and attic fungus C.) Shingle distortion/cracking due to deck movement D.) Blisters Atlas will not be responsible for damage to shingles as a result of inadequate ventilation. Ventilation provisions must meet or exceed current FHA Minimum Property Standards and conform to all building codes and regulations. To best ensure adequate ventilation and circulation of air, a combination of vents at ridge and eaves should be used. All roof structures, especially mansard and cathedral type ceilings, must have complete through ventilation from bottom to top. FHA Minimum Property Standards require one sq. ft. of net free ventilation area for each 150 sq. ft. of attic floor space to be vented; or one sq. ft. per 300 sq. ft., if vapor barrier is installed on the warm side of f �1 GlassMaste \-- Aneral Instructions -Ardmore, OK & HaG.,,rton, GA A�Pko Atlas Roofing ATLAS ROOF ; NO ceiling, or if at least one half the ventilation area is provided near the ridge. 3. ROOF DECK These instructions are for the application of Atlas asphalt shingles to nominal 7/16" thick American Plywood Association (APA/TECO) rated, code approved plywood, OSB decks or minimum 1" thick (nominal) wood decks. The plywood or non -veneer (OSB) decks must comply with the roof deck specifications of APA/TECO. Solid wood decking must be well seasoned, not over 6" (nominal) width, and fastened securely to each rafter. The deck surface must be clean, bare and flat. GlassMaster® shingles must not be applied to any surface other than roof deck types described here. Atlas also honors its Shingle Limited Warranty when Atlas shingles are installed on the Atlas CrossVent® Nailable Insulation panels. Atlas will not be responsible for the performance of its shingles if applied directly to non -vented, insulated decks composed of perlite board, plastic foam, fiberboard, gypsum plank, lightweight concrete, cementitious wood fiber; or similar materials or to any decks with insulation installed directly to the underside of the decking, with the exception of CrossVento Nailable Insulation. Atlas shingles may be installed over a roof system containing a radiant barrier material if: 1. the required full, flow through ventilation is maintained directly under the decking material in all cases, 2. the radiant barrier material is highly vapor permeable ( > 2 perms), and, 3. the radiant barrier is installed on the underside of or below the decking - not used as an underlayment above the decking. Spray -on types of below deck vapor permeable radiant barriers will be considered only on a job by job basis, and only if tested confirm > 2 perms or greater vapor permeability. 4. UNDERL.AYMENT Atlas highly recommends the use of high performance, ASTM 6757 compliant - Gorilla Guard® or Summit® proprietary underlayment products for long term roof system performance and WeatherMaster® Granular, self adhering, waterproofing underlayment for critical areas, such as valleys and eaves. Atlas does not approve the use of any self -described, metalized or metal containing category of "Radiant Barrier", as an asphalt shingle underlayment installed above the deck. Use of these types of radiant barrier would void the..shingle warranty. Underlayment-must be applied flat and -unwrinkled. Building codes vary with geographic areas, and the installation must comply with local building codes or shingle manufacturer's requirements, whichever is stricter. Shingles should be applied as soon as possible after the application of organic underlayment felt, which is not intended for prolonged exposure. Atlas recommends that the shingles be applied the same day as the felt underlayment application to avoid wetting and wrinkling. If an underlayment is used for prolonged dry -in, Atlas recommends Summit@ Synthetic Underlayment as the dry -in underlayment, for up to 6 months exposure. Standard Slope Application: Proper application requires that a single layer of approved underlayment be applied to decks with slopes of 4" per ft, or greater and consistent with all applicable building codes. This approved underlayment is a required roof assembly component to maintain a Class A fire rating of the deck assembly. Install underlayment over the entire deck, parallel to the eaves, overhanging 1/4" to 3/8", with fasteners placed 2" from the deck edge,12" O.C. across the lower edge and with 2" overlap parallel to eaves and with 4" min. end lap, parallel to the rake. Underlayment end laps shall be staggered 6 feet apart from the adjacent courses. Corrosion -resistant drip edge should be placed over the underlayment at the rake and beneath the underlayment at the eaves. Low Slope Application: 2:12-4:12 (51mm/305mm) on slopes of 2" to 4" rise per foot, a double layer of approved underlayment over the entire deck surface is required. Starting with a 19" wide strip at 2/8 GlassMaster l_,,,Ieral Instructions - Ardmore, OK & Hai :,)n, GA ® Atlas Roofing TLAS CcoO R' Ir oG eaves and overhanging the eaves 1/4" to 3/8", cover the first 19" course with a full 36" wide strip. Expose the first course 17" and continue up the deck with 36" wide strips, lapping each course 19" over the preceding course.- providing a 17" exposure. End laps for low slopes shall be of at least 12" overlap and staggered 6 feet apart. Install drip'edge over the underlayment at the rake and beneath the underlayment at the eaves. 5. FLASHING All flashing should be in place before shingles are installed. Cap flashings of sheet metal and base flashings of metal or mineral surfaced roll roofing should be used at vertical surfaces such as chimneys, skylights, vents, walls, etc. All flashings should be sealed with asphalt plastic cement. Consult the Residential Asphalt Roofing Manual published by the Asphalt Roofing Manufacturers Association (ARMA) for details concerning specific methods.and types of flashing installation. S. ICE DAM PROTECTION Eave and rake edge waterproof flashings must be installed per local building codes and where there is a possibility of icing along the eaves and rake edges causing a potential for ice damming and a backup of water. Atlas' WeatherMaster® Granular Underlayment, or equivalent must be applied directly over the decking according to application instructions provided with the product, and local building codes. The waterproof flashing material must extend up the roof at least 24" beyond the interior warm wall line, and in areas of severe icing, at least up to the highest water level expected to occur from ice dams. If the overhang requires flashing wider than 36", the horizontal lap -must be located on the overhang area and cemented or sealed. End laps must be 12" (minimum) and cemented/sealed. WeatherMaster® Granular Underlayment, as supplied by Atlas, is recommended as the first layer of Ice Dam Protection. WeatherMaster® Granular Underlayment conforms to ASTM D-1970. 7. VALLEYS Valleys must be installed before GlassMaster®. 25-shingles are applied -.Closed Cut Valley: Over felt underlayment, apply a 36" wide mineral surface roll roofing (with granule side up) or smooth roll roofing centered in the valley, nailing 2" from outer edges only. Apply all shingles on one side of valley and across center of valley, a minimum of 12". Nail a minimum of 6" away from the center line of the valley on the unshingled side and strike a chalk line 2" from the center line on the un-shingled side. Apply shingles on the unshingled side up to the chalk line and trim. Do not cut the underlying shingle. Cut upper corners of the shingle, cement and nail. See Diagram #1. GlassMaster— nieral Instructions - Ardmore; OK & Hat .,_.on, GA y Atlas Roofing ATLAS ROOFING G wealberMaste.r@l tfalley centerline o membrana pars techo dE"36"de ancho Linea. central do is limaboya No nails %vithih w"vild Droll t\ W of centerline 6" v�lde roll rcctzn n roofing t, Ningun clavo dentaa de Ids 5" dal la ilnea central Underiaymen 1 a Etta no. .irM lava extra en tvtembrana base ' ? �`a Brad of shiP41e el final de la,tela. Extend end shingle Extender la Itsphalt plastic cement `" at least 12" beyond tela frnal.al `x. valley centerline mends 1.2' centerato,,`' plaslaen asaltlea `, pasando la; . r `ti [ne central a d� t�dlrttalirtys �•'�r�n� -'1 'e'''�ry.Ra�. Glippedcorner i�l3n%r1.rt:Or37Ci�• Shingles trimmed: Z! back Irani tr Eloy et lit 6 �relas r rtacl aZ de ralrnea.ceD'tral de ra lithaboya CL OSt CUT vA. L Y 1 LIMAH YA DS TWO Ct1RtE C M S. FASTENING Placement of fasteners is critical to overall performance. New Roofing Application (first shingle layer): 4 nails are required per shingle to maintain wind performance. The nails are to be located 5/8" above the cutouts (5 5/8" above.the bottom edge of the shingle) and 1" in from each side of the shingles as illustrated in Diagram #4. 51. All nails must be driven straight, with the heads flush to the shingle surface, never cutting into the shingle. Nails must not be exposed (visible) on the finished roof. Nails must be 11 or 12 gauge; corrosion -resistant roofing nails with 3/8" minimum heads and must be a minimum of 1-1/4" long. Atlas recommends 2" nails for a roof over. However, if coils with 2" nails are not available in your 8 r" GlassMaster it _(eral Instructions - Ardmore, OK & HanI..- ern, GA © Atlas Roofing ATLAS ROOFING area, Atlas will accept the recommendation from the Asphalt Roofing Manufacturers Association (ARMA) that the nails should be long enough to penetrate 3/4" into the roof deck. Where the roof deck is less than 3/4" thick, the nails should be long enough to penetrate fully and extend at least 1/8" through the roof deck. Re -Roofing Application (second shingle layer): Requires the same nail placement as New Roofing but NAILS MUST BE A MINIMUM OF 1-1/2" LONG, NAIL PLACEMENT IS IMPORTANT FOR WIND RESISTANCE. INCORRECTLY PLACED NAILS MAY VOID WIND COVERAGE OF WARRANTY. 9. APPLICATION Prepare deck with Atlas underlayment, drip edges and flashings as recommended. Horizontal and vertical chalk lines should be utilized to ensure proper shingle alignment from eave to ridge. Starter Course: Use PRO -CUT® STARTER STRIP or you may use GlassMaster® 25 3-tab shingle for starter course. Trim off tabs and apply with 1/4" to 3/8" overhang on the eaves. Note the seal -down feature should be in line with the eave. In order to offset seams, cut 6" off the left end of the first shingle. Begin application at lower left rake of roof, and then continue across with full-length shingle, nailed with 4 nails equally spaced across the shingle and nailed 3" up from the eave. See Diagram #5. Und6dayMent ti+fetritiran� bss Drip edge 8drdd de g©tea • start1st strip �Vlth 6" removed t✓amnzat la frlmera ilia. Pon r? R relimdes DIAGRAM $ Ice dam flashing (it Yeq irsd) Tapaluntaspara acum.ulacl6n de ltilla {sis nacasio): Pulls located « 3" from eaves- .... �lavps ub.€G�d4s a�"'dEl a12.ra: .AdjaOq t. MrIpA. . .—are full length 'Las tiras adyacentes.. son' deb.largo.totai %,r',/ Self sealing adiaeslve lxositio6ed along eaves Adh�savc aulo seilanw. posid bnatio a to largt�:del;alero . Starter strips overhang -saves. .and rakes. V4" -t4 3t8'x l.as 0rasde iriiclo sgbresalen'ft alero.y volzdlzo 114"'a.3/8' First Course: Begin first full shingle at lower left rake of roof or right of vertical chalk line and continue course across roof with full shingles laid flush with starter course and fastened with 4 nails placed as specified. Note: An optional band of asphalt plastic cement meeting ASTM D-4586 may be applied to the rake of the roof with each shingle course to enhance wind resistance and to resist wind driven rain. See Diagram #6. Second Course: Cut 6" off the left.end of a shingle and apply the remaining larger piece over the first course shingle, flush with the left edge and exposing the first course 5". Proceed with full shingle across roof maintaining 5" exposure. See Diagram #6. 5/8 GlassMastei __�neral Instructions -Ardmore, OK & HG...r.�on, GA Atlas Roofing ATLA 000x i Nc Third Course: Cut 12" off the left end of a shingle and apply the remaining larger piece flush with the left rake edge, over the second course and exposing 5". Proceed across the roof maintaining the 5" exposure. See Diagram #6. Sanda do 8 - Optional 6 in. oulgactas de bond of asphalt 6rnetr14 asiallica, urrd: rlayn,nt,# cement optional t�lernbrano base Oak cub-reric Ortp edge. yr B rde de.g9teo y 5" Exposure ,S`ta1t'4hG6t3fl Wtti 18' rettt4ved xt7tip edge! eorde de go" Car�enzarla cizarte � ��' �� � � � � �� � �.,*'?� Pll�_gltarter stri t��lad icon aa" 1. Ura d fto rebrAdas ` r' y ��, Las telas paten ' Start 8ru course. el 44rdd'd.aEee yl —1 With 12' M' Q' tt St rk tat abUrse With► ull. Axogle . Ccmenzar.ta' Start 2nciaursretrtcvett ernener Ia prtrneia hprtda terc�r,hilada With t"i" cdn tcja epmplvla GORkt2't8br d s comerlia 1.:5gqudda. -- - -- NOCoif � rolkadas: Fourth Course: Cut 18" off a shingle and apply the right half over the third course, flush with the left -rake edge, exposing 5".-Proceed with full shingles across the roof, maintaining 5" exposure on the course below. Fifth Course: Repeat the above sequence to complete the roof, . STEEP SLOPIEMANgAR®/HIGH 111 IN' D APPLICA- 10N For Steep Slope/Mansard/High Wind application; 6 fasteners must be used with fasteners located 5 5/8" above shingles butt edge, 1" from each side and 1" to either side of the cutouts. Immediately upon application to slopes exceeding 45 degrees (or 12" per ft.), apply six (6) quarter size spots of asphalt plastic cement under each shingle as shown below.'Two spots of cement about the size of a quarter are to be placed under each tab. One spot is to be placed 1" to 2" from each side edge of tab and near bottom and press into position. Cement should come near edge of shingle, but not be exposed. CAUTION: Excessive use of roofing cement can cause shingles to blister, See Diagram #7. 6i GlassMaster� v'jeral Instructions - Ardmore, OK & Ha.-,,.. gin, GA AT�Atlas Roofing a0 AS uxn"u.. 11. HIP AND RIDGE To:prevent cracking in cold climates when applying to hips and ridges, shingles must be sufficiently warm and flexible. Apply Atlas Pro -Cut® Hip & Ridge shingles with a 5 5/8" exposure, beginning at the bottom of the hip or from the end of the ridge in the direction opposite of prevailing winds. Use two 1-1/2" long nails per shingle, with one nail on each side, 6 " back from the exposed end and 1" up from the edge so succeeding shingles conceal nail heads..Trim final shingle to fit and set in plastic cement. Hip and Ridge shingles may also be made from the GlassMaster® 25 3-tab shingle. Cut the strip in thirds. Taper the top portion of each slightly so that. it is narrower than. the exposed portion. See Diagram #8.- � �i�€ctann af':jsrewaiEEng iw7tt�i Dlri� �i�sndr�tu�an�lopre�rttinante �, NAIL 401CATdo{ USICAOtOt3 DE-DE Start hamacpt Camenz�r ExpcXP05n tte 5. 5 exp�swre necwwr 5Y.o1 IM.9 �Wil i0.YM1 M4R .aaM AM.iF' P.W Y.ilta Rat,+ aaaM l" CIavo DIAGRAMBta—i2^—� 12. RE -ROOFING OVER ASPHALT SHINGLES 7/8 + .. GlassMastesral Instructions - Ardmore, OK & Fla:.• -4n GA r Atlas Roofing ATLAS ROOF 4 0G Replace all missing shingles. Split and securely nail all buckles, raised tabs or curled shingles. Ensure attic ventilation complies with FHA Minimum Property Standards as stated previously. Install a layer of number 30 felt underlayment to maintain a Class A fire rating, Asphalt Felt is to be applied over the old shingles and then proceed with the new shingles as if applying a new roof. The nesting method is also acceptable over flat, uncurled, and secured three -tab shingles. IMPORTANT: NAILS MUST BE A MINIMUM OF 1-1/2" LONG AND PLACED AS STATED UNDER FASTENING. See Section 8. WARNINGS & PRECAUTIONS WARNING: Roofing application can be dangerous. All necessary precautions and safety guidelines should be observed in accordance with proper roofing trade practices. Every effort should be made to keep roof traffic to a minimum. Regular roof maintenance should be performed in the cooler parts of the day. Important Precautions: Store on flat surface. Protect from weather during storage and on job site. Sealant protection tape is placed on the back of each shingle and does not have to be removed before applying. DISCOLORATION: Some shading or variations in the colors -may occur due to positioning or embedment of the granule. When asphalt shingles are packaged, they are under a certain amount of pressure due to weight. Minor staining may occur. While in storage, they may also pick.up varying amounts of backing material used to keep the shingles from sticking together. These discolorations are.temporary and are removed by natural weathering. MINIMUM STANDARD SLOPE REQUIREMENT NOT LESS THAN 4 INCHES PER FOOT.LOW SLOPE REQUIREMENT NOT LESS THAN 2 INCHES PER FOOT. DO NOT MIX WITH MATERIAL BEARING DIFFERENT COLOR NAME. OR OTHER PRODUCT SIZES ON THE.SAME ROOF. t M fA M l,DADE.no BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION ANCE GAYMaterial ( 1361 Alps Road Wayne, NJ 074' MIAMI-DADE COUNTY, FLORIDA METRO-DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130-1563 (305) 375-2901 FAX (305) 375-2908 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AM (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AH1 may immediately revoke, modify, or suspend the use of such, product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as desdribed herein, and. has been designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: onventional Built -Up Roof System for o0 LABELING.- Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in -the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any'section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 03-0501.05 and consists of pages I tI�ro gh 19. The submitted documentation was reviewed by Jorge L. Acebo. CDate: 9.09 4/13 MlAMIDADECO JNTY 0/O8f 19 ROOFING SYSTEM APPROVAL Category Rooting Sub -Category: BUR Deck Type: Wood Maximum Design Pressure -75 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test I roduet Product Dimensions Specification Description Leak BusterTM MatrixTM 3, 5, 55 gallons ASTM D 41 Asphalt concrete primer used to promote 307 Premium Asphalt adhesion of asphalt in built-up roofing. Primer • GAF Mineral ShieldTM 60 & 1001b, bags ASTM D 1863 Granules for surfacing of exposed asphalt, Granules cold process cement or emulsion. GAF Mineral ShieldTM Granules shall be used for flashing applications only. Leak BusterTM MatrixTM 5 gallons ASTM 1227 Surface coating for smooth surfaced roofs. 305 Fibered Asphalt Emulsion Leak BusterTM MatrixTM 1, 5 gallons ASTM D 2824 Fibered aluminum coating. 303 Premium Fibered Aluminum Roof Coating LeakBustefrm MatrixTM 55 gallons Elastomeric roof coating: 322 Elastomeric Roof Coating LeakBusterTM MatrixTM 55 gallons Asphalt emulsion fibered. Select Asphalt Emulsion Fibered 306 Leak BusterTM MatrixTM 1, 5 gallons ASTM D-4586 Refined asphalt blendedwith a mineral 204 Wet/Dry Roof . ASTM D-3409 stabilizer and fibers. Permits adhesion to Cement wet and dry surfaces. RUBEROID® Modified 5 gallons ASTM D 4586 Fiber reinforced, polymer modified Flashing Bitumen Flashing cement Cement LeakBusterTM MatrixTM 5 gallons ASTM D 4586 Asphalt flashing Cement 201 Premium SBS Flashing Cement GAFGLAS® #75 39.37" (1 meter) ASTM D 4601 Asphalt impregnated and coated glass mat wide base sheet. NOA No.: 07-1219.09 Expiration Date: 11/04/13 MfAM4DADE eauiVr� Approval Date: 03/20108 Page 2 of 19 i Test Product Product Dimensions Specification Description GAFGLASO #80 39.37" (1 meter) ASTM D4601 Asphalt impregnated and coated, fiberglass ULTIMATM Base Sheet wide base sheet GAFGLAS® 39.37" (1 meter) ASTM D 2178 Type VI asphalt impregnated glass felt with Flex P1yTM 6 wide asphalt coating, GAFGLAS® Ply 4 39.37" (1 meter) ASTM D 2178 Type rV asphalt impregnated glass felt with wide asphalt coating. GAFGLAS® Mineral 39,37" (1 meter) ASTM D 3909 Asphalt coated, glass fiber mat cap sheet Surfaced Cap Sheet wide surfaced with mineral granules. GAFGLAS® . 39:37" (1 meter) ASTM D 3909 Asphalt coated, glass fiber mat cap sheet EnergyCapTM Mineral wide surfaced with mineral granules with factory Surfaced Cap Sheet applied layer of TOPCOATOEnergyCoteTM. GAFGLAS® 39.37".(l meter) ASTM D 4897 Fiberglass base sheet impregnated and STRATAVENT® wide D 3672 coated on both sides with asphalt. Surfaced EliminatorTM Perforated on the bottom side with mineral granules embedded in asphaltic coating with factory perforations. GAFGLAS® Flashing Various Asphalt coated glass fiber mat flashing sheet available in three sizes. GAFGLAS 39-37" (1 meter) ASTM D 4897 Fiberglass base sheet impregnated and STRATAVENTO wide D 3672 coated on both sides with asphalt. Surfaced EliminatorTM Nailable on the bottom side with mineral granules . embedded in asphaltic coating. RUBEROID® SBS 1 metei° (39.37") -ASTM D-6164 Non -Woven Polyester mat coated with Heat-WeIdTM Smooth wide . polymer -modified asphalt and smooth surfaced. RUBEROO SBS I meter (39.37") ASTM D-6164 Non -Woven Polyester mat coated with Heat-WeIdTM Granule wide polymer modified asphalt and surfaced with mineral granules.. RUBEROID® SBS 1 meter (39.37") ASTM D-6164 Non -Woven Polyester mat coated with fire Heat-WeIdTM 170 FR wide retardant polymer modified asphalt and ' surfaced with mineral granules. RUBEROID® SBS 1 meter (39.37") ASTM D-6164 Non -Woven Polyester mat coated with Heat WeIdTM PLUS wide polymer modified asphalt and surfaced with mineral granules. RUBEROID® SBS 1 meter (39.37") ASTM D-6164 Non -Woven Polyester mat coated with fire Heat-WeIdTM PLUS FR wide retardant polymer modified asphalt and surfaced with mineral granules. RUBEROID® SBS 1 meter (39.37") ASTM D-6164 Non -Woven Polyester niat coated with Heat WeIdTM 25 wide polymer -modified asphalt and smooth surfaced. RUBEROID® Modified 39.37" (1 meter) ASTM D4601, Premium glass. fiber reinforced SBS Base Sheet wide Type 11, UL modified base sheet Type G2.BUR NOA No.: 07-1219.09 Expiration Date: W04113 MIAMI•DADE couN7Y approval Date: 63/20/08 Page 3 of 19 Product RUBEROID® 20 RUBEROID® Mop Granule RUBER6ID�' Mop Plus (Granule) RUBEROID® MOP Smooth RUBEROID® MOP 170FR RUBEROID® MOP FR RUBEROIbo TORCH Smooth . RUBEROID® TORCH Granule RUBEROID® TORCH PLUS (Granule) RUBEROID®TORCH FR RUBEROID® I70FR TORCH RUBEROID® 30 RUBEROID® 30 FR RUBEROID® ULTRACLAD" RUBEROID®DuaI FR Vent Stacks (metal and plastic) APPROVED Test Product Dimensions Specification Description 39.37" (1 meter) ASTM D 6163 SBS modified asphalt base sheet and wide ASTM D 5-147 interply sheet reinforce with a glass fiber mat. 39.37" (1 meter) ASTM D 6222 Non -woven polyester mat coated with wide ASTM D 5I47 polymer modified asphalt and surfaced with mineral granules. 39.37" (1 meter) ASTM D 6222 Non -woven polyester mat coated with wide ASTM D 5147 polymer modified asphalt and surfaced with miner al granules. 39.37" (1 meter) ASTM D 6164 Non -woven polyester mat coated with wide ASTM D 5147 polymer -modified asphalt and smooth surfaced. 39.37" (1 meter) ASTM D 6164 Non -Woven polyester mat coated with fire wide ASTM D 5147 retardant polymer modified asphalt and surfaced with mineral granule$, 39.37" (1 meter) ASTM D 6164 Non -Woven polyester mat coated with fire wide ASTM D 5147 retardant polymer modified asphalt and surfaced with mineral granule's. 39.37" (1 meter) ASTM D 5147 Heavy duty, polyester reinforced, asphalt wide modified bitumen membrane, smooth surface. 39.37" (1 meter) ASTM D 5147 Asphalt impregnated, coated felt, surfaced wide with mineral granule. 39.37" (1 meter) ..ASTM D 6222 Heavy duty, polyester reinforced, asphalt wide ASTM D 5147 modified bitumen membrane, granule surface. 39.37" (1 meter) ASTM D 6222 Heavy duty, polyester reinforced, coated wide ASTM D 5147 with -fire retardant asphalt modified bitumen membrane, granule surface. 39.37" (1 meter) ASTM D 6222 Heavy duty, polyester reinforced, coated Wide ASTM D 5147 with fire retardant asphalt modified bitumen membrane, granule surface, 39.37" (I meter) ASTM D 6163 Non -woven fiberglass mat coated with wide ASTM D 5147 polymer modified asphalt and surfaced with mineral granules. 39.37" (1 meter) ASTM D 6163 Non -woven fiberglass mat coated with fire wide ASTM D 5147 retardant polymer modified asphalt and surfaced with mineral granules. 39.37" (1 meter) ASTM D 6298 Woven fiberglass mat coated with Polymer wide ASTM D 5147 modified asphalt and surfaced with aluminum, copper or stainless steel foil, 39.37" (1 meter) ASTM D 6164 Non -woven polyester and fiberglass mat Wide ASTM D 5147 coated -with file retardant, polymer modified asphalt and surfaced with mineral granules. TAS 100(A) One way valve vent used to relieve built-up ASTM D 1929 pressure within the roof system, GAF Vent ASTM D 635 Stacks -are available in metal or plastic. NOA No.: 07-1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 4 of 19 Test Product Product Dimensions Specification Description Leak BusterTM MatrixTM 5 gallons ASTM D2824, Non-fibered aluminum pigmented, asphalt 302 Non Fibered Type 1 roof coating. Aluminum Roof Coating GAF Built -Up Roofing 100 lb. cartons, ASTM D312, Interply mopping and surfacing asphalt. Asphalt bulk Types 1, IT, III and IV RUBEROID° MOD 60 lb, kegs SEBS modified asphalt. Asphalt, Asphalt L & Asphalt P • Leak BusterTM MatrixTM 5 gallons Surface coating for smooth surfaced and 602 mineral surfaced roofs. Leak BusterTM MatrixTM 5 gallons Surface coating for smooth surfaced and 715 mineral surfaced -roofs. Leakl3usteim MatrixTM 2 gallons Surface coatuig• for smooth surfaced and 531 WeatherCoteTM mineral surfaced roofs. SeamCoteTM 2, 5 gallons proprietary Elastomeric roofing membrane. . FireOutTm 5, 55 gallons Low VOC, fire barrier coating. VersaShield° 350 sq fl. roll Non -Asphaltic Fiberglass -Based Underlayment. VersaShield FB-1S 350 sq ft. roll Non -Asphaltic Fiberglass -Based Underlayment. VersaShield® FB-2S 350 sq ft. roll Non -Asphaltic Fiberglass -Based Underlayment, TOPCOAT' FireShiele 5, 55 gallons ASTM D-412 Elastomeric roofing membrane MB ASTM D-21-96 ASTM D1475 ASTM E-1644 Leak BusterTM MatrixTM 5 gallons ASTM D3019 Cold Applied Modified SEBS Asphalt 201 SBS Flashing Adhesive — Flashing Grade, Cement Leak BusterTM MatrixTM 5 gallons ASTM D3019 Cold Applied Modified SEBS Asphalt 102 SBS Adhesive Adhesive. Leak BusterTM MatrixTM 5 gallons ASTM D4586 Cold Applied Modified SEBS Asphalt 202 SBS Flashing Adhesive -- Flashing Grade. Cement Leak BusterTM MatrixTM 5 gallons ASTM D4586 Standard Plastic Asphalt Roofing Cement 203 Plastic Roof Cement Leak BusterTM MatrixTM 5 gallons ASTM D3019 Cold Applied Asphalt Adhesive. 103 Cold Process Adhesive NOA No.: •07-1219.09 Expiration Date: 11/04/13 MiaMi•flane couNtY Approval Date: 03/20/08 Page 5 of 19 Product Leak BusterTM MatrixTM 303 Fibered Aluminum Roof Coating Leak BusterTM MatrixTM 304 Non Fibered Aluminum Roof Coating Test Dimensions Specification Product Description 5 gallons ASTM D 2824 Fibered aluminum coating. 5 gallons ASTM D2824, Non-Fbered aluminum pigmented, asphalt Type I roofcoating. .APPROVED INsuLATIONS: Product Name- EnergyGuardTM RA, RN Composite A & N EnergyGuardTM Fiberboard EnergyGuardTM Permalite EnergyGuardTM GAFCANTTM EnergyGuardTM Permalite Recover Board EnergyGuardTM Tapered Edge Strip EnergyGuardTM Per[ite EnergyGuardTM High Density Fiberboard EnergyGuardTM Composite EnergyGuardTM Composite RA Wood Fiber High Density Wood Fiberboard Perlite Insulation Dens Deck, Dens Deck® Prime, Dens DecleDura GuardTM Structodek SecurockTM ° APPROVED, - Table 2 Product Description Polyisocyanurate foam insulation Polyisocyanurate foam insulation with high density fiberboard or Permalite perlite insulation. . Fiberboard insulation. Perlite insulation board. Cut perlite board Perlite recover board Manufacturer (With Current NOA) BMCA GAF Materials Corp. GAF. Materials Corp. GAF Materials Corp. GAF Materials Corp. . GAF Materials Corp. Tapered perlite board GAF Materials Corp. Perlite insulation board GAF Materials Corp. High density Wood fiberboard insulation. GAF Materials Corp. Polyisocyanurate/wood fiberboard composite . Polyisocyanurate/wood fiberboard composite Wood fiber insulation board Wood fiber insulation board Perlite insulation board Water resistant gypsum board Wood fiber insulation board Fiber reinforced roof board BMCA BMCA generic generic generic G-P Gypsum Corp Knight Celotex USO Corporation NOA No.: 07-1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 6 of 19 APPROVED FASTENERS: TABLE3 Fastener Product Product Manufacturer Number "Name Description Dimensions (With Current NOA) 1. D IIJecTM 412 Standard, Insulation fastener and Various GAF Materials Corp. #14 and #15 extra Heavy. Base Play fastener for Duty Fastener, Heavy steel, wood & concrete Duty Roofing•Fastener decks. 2. Drill-TecTM ASAP Pre -assembled Drill- Various GAF Materials Corp. TecTM Fasteners and metal and plastic plates. 3. Drill-TecTM #12 or #14 Base sheet fastening Various GAF Materials Corp. Standard screws with assembly. AccuTrac Plate 4. Drill-TecTM Galvalume Round Galvalume stress 3" and 3 1/2" GAF Materials Corp. Plates plates, 5. Drill-TecTM Round polypropylene 3" and-31/2" GAF Materials Corp, Polypropylene Plates stress plates. 6. Drill-TecTM AccuTrac Square Galvalume® 3" Square GAF Materials Corp. Plate . coated steel plate. EVIDF,NCE SUBMITTED: Test Aeeney Test Identifier Description Date Factory Mutual Research Corp. J.I.2B8A4.AM 4470 07.02.97 J.I.3B9Q1:A.M 4470 01.08.98 J.I.ODOA8.AM 4470 07.09.99 M. ODIA8.AM 4470 -TAS 114 07.29''94 J.I.OY9Q5.AM 4470 - TAS 114 04.01.98 3029832 4470-TAS"114 05,11.07 PRI Asphalt Technologies, Inc, GAF-012-02-02 Physical Properties 11.06.01 GAF-020-02-01 ASTM D 4977. 02.01.02 lkT of S. Fl. 02-005 TAS 114 01.18.02 02-014 TAS 114 03,22.02 MfAM! DADS COUN NOA No.: 07-1219.09 Expiration Date: 11/04113 Approval Date: 03/20/08 Page 7 of 19 t APPROVED ASSEMBLIES Deck Type II: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank System Type A: Anchor sheet mechanically fastened, all layers of insulation adhered with approved asphalt. All General and System Limitations shall apply. One or more layers of any of the following insulations. . Insulation Layer (Table 2) Insulation Fasteners Fastener (When applicable: Steel plate only =S, plastic plate only (Table 3) Density/fe =P). EnergyGuardTM, EnergyGuardTM Composite, EverGuard® ISO,'EnergyGuardTM RA, EnergyGuardTM RA Composite Minimum 1" thick N/A' N/A EnergyGuardTM High Density Wood Fiber, EnergyGuardTM Recover Board, Wood Fiber, Minimum Y2" thick N/A N/A EnergyGuardTM Perlite Minimum Y4" thick • N/A N/A Fiberglas (Min. `116" thick) N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 Ibs/100 fe. Please refer to Roofing Application Standard'RAS 117 for insulation attachment. Insulation -listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. GAF requires either a ply of GAFGLASP STRATAVEN-r EliminatorTM Perforated laid dry or a layer of EnergyGuardTM Perlite or wood fiber overlay board on all isocyanurate applications, Fire Barrier: FireOutTM Fire Barrier Coating, VersaShiel& Non -Asphaltic Fiberglass -Based (optional) Underlayment or SecurockTM. Anchor sheet: GAFGLAS® 480 ULTIMATM Base Sheet, STRATAVENT® EliminatorTM Nailable, RUBEROID® Modified Base Sheet, RUBEROID® 20, RUBEROID Heat-WeldTM Smooth or RUBEROID® Heat-WeIdTM 25 base sheet mechanically fastened as described below; Fastening Options: GAFGLAS® Ply 4, GAFGLAS® Flex P1yTM 6, GAFGLAS® 475 Base Sheet or any of above Anchor sheets attached to deck with approved annular ring shank naiIs and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field. (Maximum Design Pressure -�S psf, See General ,Limitation 47) NOA No.; 07-1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 8 of 19 Fastening Options: GAFGLAS® Ply 4, GAFGLAS® FIex PIyTM 6, GAFGLAS® #75 Base Sheet or any of above Anchor sheets attached to deck with Drill-TecTM #12 standard, 014 or # 15 Screws and 3" Drill-TecTM steel plate or Drill-TecTM AccuTrac Plates, 12" o.c. in 3 rows, One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c, in the field of the sheet, (Maximum Design Pressure_25_nsf. See General Limitation 97) GAFGLAS® Flex PIyTM 6, GAFGLAS #75 Base Sheet or any of above Anchor sheets attached to deck with approved annular ring shank nails and tin caps at a. fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressured52.S psf, See General Limitation 97) GAFGLAS #80ULT11 AT"', RUBER0Ill®20, RUBEROID®Mop Smooth, base sheet attached to deck with approved 1'/4" annular ring shank nails and inverted 3" steel plate at a fastener spacing of 9" o.c. at the 4" lap and in two rows staggered with a fastener spacing of 9" o.c. in the center of the membrane. (Maximum Design Pressure -60 psf, See General Limitation #7) GAFGLAS° 975 Base Sheet or any of above Anchor sheets attached to deck with Drill-TecTM #12 standard, 914 br # 15 Screws and 3" Drill-TecTM steel plate or Drill-TecTM AccuTrac Plates, IT'o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —60 psf, See General Limitation #7) Any of above Anchor sheets attached to deck approved annular ring shank. nails and 3" inverted Drill-TecTM insulation plates at a fastener spacing of 9" o.c. at the 4" lap staggered in two rows 9" -in the field. (Maximum Design Pressure —60 psf, See General Limitation 97) GAFGLAS #75 Base Sheet or any of above Anchor sheets attached to deck- with Drill-TecTM 912 standard, #14 or # 15 Screws and 3" Drill-TecTM steel plate or Drill-TecTM AccuTrac Plates, 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —75 psf, See General Limitation #7) Base Sheet: (Optional) Install one ply of GAFGLAS #75, GAFGLAS® #80 ULTIMATM Base'Sheet, GAFGLAS® STRATAVENT® Eliminatofm Perforated, RU_BEROID`� Modified Base Sheet, RUBEROID®Mop Smooth, RUBEROID0 20 RUBEROID® Heat-WeldTM Smooth or RUBEROIID® Heat -re directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq; (see General Limitation- #4). Ply Sheet: One or more plies GAFGLAS® PLY 4, GAFGLAS® Flex PIyTM 6 sheet, #80 Ultima, RUBEROID5 Mop Smooth or RUBEROID° 20 adhered -in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. NOA No.: 07-1219.09 Expiration Date: 11/04/13 , Approval Date: 03/20/08 Page 9 of 19 Cap Sheet: (Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet or GAFGLAS®EnergyCapTm Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20.40 lbs./sq. Surfacing: (Optional, required if RUBEROID° MOP Smooth or RUBEROID® 20 is top membrane) Install one of the following: 1. Gravel or slag applied at 400 lbs./sq. and 300 lbsJsq. respectively in a flood coat of approved asphalt at 60 lbs./sq. or applied in a*flood coat of Leak BusterTM MatrixTM 103 Cold Process Adhesive applied at a rate of 3 gal./sq. 2. GAFGLAe Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. 3. Leak BusterTM MatrixTM 303 Premium Fibered Aluminum Roof Coating, at 1.5 gal./sq. 4. Leak 13usterrM MatrixTM 715, Leak BusterTM MatrixTM 322, TOPCOAT® MB+, TOPCOAT® Fireshield Elastomeric Roofing Membrane, applied at 1 to 1.5 gal./sq. 5. Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane, BnergyCoteO roof coating applied at 1 to 1.5 gal./sq. 6. TOPCOAT* Surface Seal, TOPCOAT® Fireshiele SB Solvent based Elastomeric Roofing Membrane applied at Ito 1.5 gal./sq 7.. Advance Green Technologies .Photovoltaic Laminate solar energy collector auxiliary roof equipment installed in compliance with manufacturer's.specifications and applicable Building Codes. Maximum Design Pressure: See Fastening above. APPROVED °:? NOA No.: 07-1219.09 Expiration Date: 11104/13 Approval Date: 03/20/08 Page 10 of 19 'Deck Type 11: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank System Type B: Optional base sheet laid dry; base layer of insulation mechanically fastened, optional top layer adhered with approved asphalt. All General and System Limitations shall apply. One or more layers of any of the following insulations. Insulation for Base Layer (Table 2) When applicable: Steel plate only =S, plastic plate only =P EnergyGuardTM, EnergyGuardT" s RA Minimum 1.3" .thick EnergyGuardTM RN Minimum 1.4" thick EnergyGuardTM Composite, EnergyGuardTM RA Composite Minimum 1.5 thick EnergyGuardTM Perlite Minimum 3/4" thick Insulation Fasteners Fastener (Table 3) Density/ft2 1, 2, or 3 1:3 ft2 1, 2, or 3 1:3 ft2 1:3 ft2 1 S(3.5"), or 3 1:2 ft2 EnergyGuardTM Fiberboard, EnergyGuardTM High Density Fiberboard Minimum 1" thick 1, 2, or 3 1:4 ft2 Note: Base layer shall be mechanieally attached with fasteners and density described. Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be increased maintaining the same fastener density (See Roofing Application Standard RAS 117 for fastening details). GAF requires either a ply of GAFGLAS® STRATAVENTO Eliminatoe" perforated laid dry or a layer of EnergyGuardTr4 or wood fiber overlay board on all isocyanurate applications. Insulation for Top Layer (Table 2) Insulation Fasteners Fastener When applicable: Steel plate only =S, plastic plate only =P (Table 3)' De4sity/ff2 Any of the insulations listed for Base Layer, above. N/A N/A EnergyGuardTM high Density Wood Fiber, EnergyGuardT14 High D ensity. Wood Fiberboard, EnergyGuarVm Recover Board Minimum %2"thick NIA N/A Note:.Optional top layer of insulation shall be adhered with approved asphalt within the EVT range and at a rate of 20-40 lbs/100 W. PIease refer to Roofing Application Standard RAS 11.7 for insulation attachment. Composite insulation boards used as a tbp layer shall be installed with the polyisocynnurate face down. Fire Barrier: FireOutTM Fire Barrier Coating, VersaShieldo Ndn-Asphaltic Fiberglass -Based (optional) Underlayment or SecurockTM. NOA No.: 07-1219.09 Expiration Date: 11/04/13 htiaMivarrscouNrr Approval.Date - 03/20/08 Page 11 of 19 Base Sheet: (Optional) Install one ply of GAFGLAS® 075, GAFGLAS° 980 ULTiMATM Base Sheet, GAFGLAS® PLY 4, .GAFGLAS® Flex P1yTm 6, GAFGLAS® STRATAVENTs' Eliminator Perforated(laid dry), RUBEROID® Modified Base Sheet, RUBEROID® Mop Smooth or RUBEROID° 20 directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq; (see General Limitation 94). Ply Shept; Two or more plies of GAFGLAS® PLY 4, GAFGLAS® FlexPly" 6 ply sheet, #80 Ultima, RUBEROMP Mop Smooth or RUBEROID® 20 adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq, (See specification number for appropriate number of plies). Cap Sheet: (Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet or GAFGLAS®EnergyCapTM Mineral Surfaced Cap Sheet adhered in a full . mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. (See GAF appIicatiQn instructions for approved method of installation). Surfacing: (Optional, required if RUBEROID® MOP Smooth or RUBEROID® 20 is top membrane) Install one of the following; 1. Gravel or slag applied at 4001bs./sq, and 300 lbs./sq. respectively in a flood coat of approved asphalt at 601bs,/sq. or applied in a flood coat of Leak BusterTM MatrixTM 103 Cold Process Adhesive applied at a rate of 3 gal./sq: 2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLASO Energy Cap Mfiieral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-401bsJsq, 3. Leak BusterTM MatrixTM 303 Premium Fibered Aluminum Roof Coating, at 1.5 gal./sq. 4. Leak BusterTM MatrixTM 715, Leak•Bustefrm MatrixTM 322, TOPCOAT® MB+; TOPCOAT' Fireshield Elastomeric Roofing Membrane, applied at 1 to 1.5 galJsq. 5. Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane, EnergyCoteg roof coating applied at 1 to 1.5 gal./sq. 6. TOPCOAT® Surface Seal, TOPCOAT® Fireshi-,ie SB Solvent based Elastomeric Roofing Membrane applied at Ito 1.5 gal./sq 7. Advance Green Technologies Photovoltaic Laminate solar energy collector auxiliary roof equipment installed in compliance with manufacturer's specifications and applicable Building -Codes. Maximum Design Pressure: -45 psf; (See General Limitation #7) NOA No.: 07-1219.09 Expiration Date: 11104113 Approval Date: 03/20/08 . Page 12 of 19 Deck Type 11: Wood, Insulated Deck Description: 19/321' or greater plywood or wood plank System Type C: One or more layers of insulation simultaneously attached; Base layer optional. All General and System Limitations shall apply. One or more layers of any of the following insulations. Insulation for Base Layer (Table 2) (When applicable: Steel plate only =S, platic plate only =P) EnergyGuardTM RN, EiiergyGuardTM, EnergyGuardTM RA Minimum 1.3" thick EnergyGuardTM Min.1.4" thick EnergyGuardTM Composite, EnergyGuardT"r RA Composite Minimum 1.5" thick EnergyGuardTM Perlite Minimum %" thick Insulation Fasteners Fastener (Table 3) Density/ft N/A N/A N/A N/A N/A N/A N/A N/A Wood Fiber, EnergyGuardTM Fiberboard, EnergyGuardTm High Density Fiberboard Minimum 1" thick N/A N/A Note: -All layers shall be simultaneously fastened; see top layer below for fasteners and density. Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining' the same fastener density. Please i efei to Roofing Application Standard RAS 117 ' for insulation attachment. 'GAF requires either a ply of GAFGLAS®. STRATAVENTO EIirninatorTM perforated laid dry or a layer of EnergyGuardTM Perlite or wood fiber overlay board on all isocyanurate applications. Insulation for Top Layer (Table 2) Insulation Fasteners Fastener When applicable: Steel plate only =S, plastic plate only =P (Table 3) Density/fe EnergyGuard, EnergyGuard RA Minimum 1.3" thick 1, 2, or 3 1:3 ft2 EnergyGuardTM RN Minimum 1.4" thick 1, 2, or 3 1:3 ft2 EnergyGuardTM Composite, EnergyGuardTM RA Composite Minimum 1•.5 thick 3 1:3 R2 EnergyGuardThi Perlite Minimum g/" thick IS(3.5"), or 3 1:2 RI Fiberglas Minimum thick 1, 2, or 3 1:2.67 W Wood Fiber, EnergyGuardTM Fiberboard, EnergyGuardTM High Density )fiberboard Minimum 1" thick 1, 2, or 3 1:4 ft2 NOA No.: 07-1219.09 Expiration Date: 11/04/13 Approval Date: 031Z0/08 Page 13 of 19 Note: Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fasterie'r density, Please refer to Roofing Application Standard RAS 117 for insulation attachment. GAF requires either a ply of GAFGLAS® STRATAVENTO Elimina'toirl" Perforated laid dry or a layer of EnergyGuardTM Perlite or wood fiber overlay board on all isocyanurate applications. Fire Barrier: FireOutTM Fire Barrier Coating, Versa.Shield®Non-Asphaltic Fiberglass -Based (optional) Underlayment or SecurockTM. Base Sheet: (Optional) Install one ply of GAFGLAS® 475, GAFGLAS° 980 ULTIMATM Base Sheet, GAFGLAS® PLY 4, GAFGLAS-FIexPlim 6, GAFGLAS® STRATAVENT" EliminatorTM Perforated (laid dry), RUBEROID® Modified Base Sheet, RUBEROID® Mop Smooth or RUBEROID® 20 directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the CVT range and at a rate of 20-40 lbs./sq.. if -base sheet is applied -directly to polyisocyanurate insulation only a spot or strip mopped application as detailed in this approval the use of an overlay -board is approved; see General Limitation f4. Ply Sheet: Two or more plies of GAFGLAS® PLY 4, GAFGLAS® F1exPlyTm 6 ply sheet; #80 ULTIMATM; , RUBEROe Mop Smooth or RUBEROID° 20 adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Cap Sheet: (Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet or GAFGLAS° EnergyCapTM Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Surfacing: (Optional, required if RUBEROID® MOP Smooth or RUBEROV 20 is top membrane) Install one of the following: 1. Gravel or slag applied at 400 lbsJsq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. or applied in a flood coat of Leak BusterTM Matrhxm 103 Cold Process Adhesive applied at a rate of 3 gal./sq. 2. GAF GLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-401bs./sq. 3. Leak BusterTM MatrixTM 303 Premium Fibered Aluminum Roof Coating, at 1.5 galJsq. 4. Leak BusterTM MatrixTM 715, Leak BusterTM MatrixTM . 322, TOPCOAT® MB+, TOPCOAT® Fireshield Elastoriieric Roofing Membrane, applied at 1 to 1.5 galJsq. 5. Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofing . Membrane, EnergyCoteOD roof coating applied at 1 to 1.5 gal./sq. 6. TOPCOAT° Surface Seal, TOPCOAT® Fireshieldo SB Solvent based Elastomeric Roofing Membrane applied at Ito 1.5 galJsq 7. Advance Green Technologies Photovoltaic Laminate solar energy collector auxiliary roof equipment installed in compliance with manufacturer's specifications and applicable Building Codes. Maximum Design Pressure: -45 psf; (See General Limitation 97) NOA No.: 07-1219.09 Expiration Hate: 11/04/13 MtAMt•DADE couNTT Approval Bate: 03/20/08 Page 14 of 19 Deck Type 11- Wood, Insulated Deck Description: 19/32" or greater plywood.or wood plank System Type D: Insulation and Base sheet simultaneously All General and System Limitations shall apply. One or more layers of any of the following insulations. Insulation Layer loosely laid with firmly butted joints. Insulation Fasteners Fastener (Table 3) Density/fe EnergyGuardTM, EnergyGuardTM RA, Minimum 1.3" thick N/A NIA EnergyGuardT"t High Density Fiberboard, EnergyGuardT"r Fiberboard Minimum 1" thick N/A N/A Fire Barrier: FireOutTM Fire Barrier Coating, VersaShieleNon-Asphaltic Fiberglass -Based (optional) Uhderlayment or SecurockTM. Base Sheet: Install one ply of GAFGLAS® #75, GAFGLAS® 980 Ultima ULTIMATM Base Sheet, GAFGLAS® STRATAVENTO EliminatorTM Nailable. or RUBEROID® 20 base sheet applied over the loose laid insulation with 2" side laps mechanically fastened as described below; Fastening Options: Drill-TecTM #12 standard, #14 or # 15 Screws and 3" Drill-TecTM steel plate or Drill-TecTM AccuTrac Plates are installed through the base sheet and insulation in 3 rows 12" o.c. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the'sheet. (Maximum Design Pressure —45 psf, See General Limitation #7) Drill-TecTM #12 standard, #14 or # 15 Screws and 3" Drill-TecTM steel plate or Drill-TecTM AccuTrac Plates are installed through the base sheet and insulation in 4 rows 8" o.c. One 'row is in the 2" side lap. The other 3 rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure—75,usf, See General Limitation 97) GAFGLAS' #80ULTIMATM, RUBEROID®20, RUBEROID®Mop Smooth, base - sheet attached to deck with approved annular ring shank nails with a minimum embedment of 1" into the wood substrate and inverted 3" steel plate at a fastener spacing of 9" o.c. at the 4" lap and in two rows staggered with a fastener spacing of 9" o.c. in the center of the membrane. (Maximum Design Pressure —60 psf, See General Limitation #7) Drill-TecTM #12 standard, #14 or # 15 Screws and 3" Drill-TecTM steel plate or Drill-TecTM AccuTrac Plates in 4 rows 12" o.c. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —60 psf, See General Limitation #7) Ply Sheet: One or more plies GAFGLAS® PLY 4, GAFGLAS®, GAFGLAS® FlexPlyTM 6 sheet, #80 UItima or RUBEROID® 20adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. NOA N6.: 07-1219.09 Expiration Date: 11/04/13 QMIAMMI•aaon =INTY Approval Date: 03/20/08 Page 15 of 19 Cap Sheet: (Optional) One ply of GAFGLASO Mineral Surfaced Cap Sheet or GAFGLAS® EnergyCapTM Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range. and at a rate of 20-401bs./sq. Surfacing: (Optional, required if RUBEROID® MOP Smooth or RUBEROID® 20 is top membrane) Install one of the following: 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively. in a flood coat of approved asphalt at 60 lbs:/sq. or applied in a flood coat of Leak BusterTM MatrixTM 103 Cold Process Adhesive applied at -a rate of 3 gal./sq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS° Energy Cap Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbsJsq: 3. Leak-BusterTM MatrixTM 303 Premium Fibered Aluminum Roof Coating, at 1.5 gal./sq. 4, Leak BusterTM MatrhCrm 715, Leak BusterTM MatrixTM 322, TOPCOAT® MB+, TOPCOAT® Fireshield Elastomeric Roofing . Membrane, applied at 1 to 1.5 gal./sq. 5'. Leak BusterTM MatrixTm 602 MB Xtra Elastomeric Roofing Membrane, EnergyCote® roof coating applied at 1 to 1.5 gal./sq. 6. TOPCOAT® Surface Seal, TOPCOA74 Fireshiele SB Solvent based Elastomeric Roofing Membrane applied at Ito 1.5 gal./sq 7. Advance Green Technologies Photovoltaic Laminate solar energy collector auxiliary roof equipment installed in compliance with manufacturer's specifications and applicable Building Codes. Maximum Design Pressure: See Fastening Above NOA No.: 07-1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 16 of 19 Deck Type 1: Wood, Non -insulated ' Deck Description: 19/32" or greater plywood or wood plank decks System Type E: Base sheet mechanically fastened. All General and System Limitations shalt apply. Fire Barrier: FireOutTM Fire Barrier Coating, VersaShield°Non-Asphaltic Fiberglass -Based .(optional) Underlayment or SecurockTm. Base sheet: GAFGLAS® #80 ULTIMATM Base Sheet, STRATAVENTO Eliminatofrm Nailable, RUBEROIDO Modified Base Sheet, RUBEROe 20, RUBEROID' Heat-WeldTM Smooth or RUBEROID" Heat -Weld' 25 base sheet mechanically fastened to deck as described below; Fastening Options:. GAFGLAS® Ply 4, GAFGLAS" Flex PlyTM 6, GAFGLASO.#75 Base Sheet or any of above Base sheets attached to deck with approved annular ring.shank nails and tin caps at a fastener spacing of, 9" o.c. at the lap staggered and in. two rows 12" o.c. in the field. (Maxim um Design Pressure --45 psf, See General Limitation #7) r MIAl�11-DADE COUNTY GAFGLASO Ply 4, GAFGLASO Flex P1yTM 6, GAFGLAS® 475 Base Sheet or any of above Base sheets attached to deck with Drill-TecTM 912 standard, 914 or # 15 Screws and 3" Drill-TecTM steel plate or Drill-TecTM AccuTrac Plates, 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately: I T'o.c. in the field of the sheet. (Maximum Design Pressure —45 ps, ,, See General Limitation #7) GAFGLAS® Flex P1yTM 6, GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure —52.5 psf, See General Limitation #7) GAFGLAS® #80ULT1MATM, RUBEROID®20, RUBEROID®Mop Smooth, base sheet attached to deck with approved 1'/a" annular ring shank nails and inverted 3" steel plate at a fastener spacing of 9" o.c. at the 4" lap and in two rows staggered with a fastener spacing of 9" o.c. in the center of the membrane. (Maximum Design Pressure —60 psf, See General Limitation #7) GAFGLAS® 475 Base Sheet or any of above Base sheets attached to deck with Drill-TecTM #12 standard, 914 or # 15 Screws and 3" Drill-TecTM steel plate or Drill-TecTM AccuTrac Plates, 12" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —60 psf, See General Limitation #7) Any of above Base sheets attached to deck approved annular ring shank nails and;3" inverted Drill-TecTM insulation plates at a'fastener spacing of 9" o.c. at the 4" lap staggered in two rows 9" in the field. (Maximum Design Pressure —60 psf, See General Limitation #7) NOA, No.: 07-121.9.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 17 of 19 GAFGLAS® 975 Base Sheet or any of above Base sheets attached to deck with Drill-TecTM 912 standard, #14 or # 15 Screws and 3" Drill-TecTM steel plate or Drill-TecTM AccuTrae Plates, 8" o.c. in 4,rows. One raw is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. -in the field of the sheet. (Maximum Design Pressure —7S psf, See General Limitation V) Ply Sheet: One or more plies of GAFGLASO PLY 4, #80 ULTIMA, RUBEROID® MOP Smooth or RUBEROe 20 adhered in a full mopping of Approved asphalt applied within the EVT range and at a rate of 20-401bs./sq. Cap Sheet: (Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet or GAFGLAeEnergyCapTM Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Surfacing: (Optional, required if RUBEROI)o MOP Smooth or RUBEROID® 20 is top membrane) Install one of the following: 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. or applied in a flood coat of Leak BusterTM MatrixTM 103 Cold Process Adhesive applied at a rate of 3 gal./sq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs.lsq. 3. Leak BusterTM MatrixTM 303 Premium Fibered Aluminum Roof Coating, at 1.5 gal./sq. 4. Leak BusterTM MatrixTM 715 , Leak BusterTM MatrixTM 322, TOPCOAT* MB+, TOPCOAT'' Fireshield Elastomeric Roofing Membrane, applied at I to 1.5 gal./sq. 5. Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane, FaiergyCote@ roof coating applied at I to 1.5 gal./sq. 6. TOPCOAT9 Surface Seat, TOPCOA'& Fireshieldo SB Solvent based Elastomeric Roofing Membrane applied at Ito- 1.5 gal./sq 7. Advance Green Technologies Photovoltaic Laminate solar energy collector auxiliary roof equipment installed in compliance with manufacturer's specifications and applicable Building Codes. Maximum Design Pressure: See Fastening Above NOA No.: 07-1219.09 Expiration gate: 11/04/13 -- MIAP}LDAPE'COUN'fY Approval Date: 031201.08 Page 18 of 19 WOOD DECK SYSTEM MUTATIONS: I A slip sheet is required with Ply 4 and Flex P1yTM 6 when used as a mechanically fastened base or anchor { sheet. 2. Minimum '/4" Dens Deck -TM or ''/z" Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL LBRTAUONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-401bs./sq., or mechanically attached using the fastening pattern of the top layer 3: All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. .An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. if no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 1211 diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center -of the sheet •allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every IT in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to &-maximum design pressure of -45 psf. S. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 IV., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field- tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anehor/base sheet or -membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be, less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the.enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, Generallimitation 09 wilI not be applicable.) 8. All attachment and sizing of -perimeter nailers,'metal profile, and/or flashing termination designs shall conform with Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred Nvithin this NOA, General Limitation 97 will not be applicable.) 10.. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B-72 of the Florida Administrative Code. END CE THIS ACCEPTANCE APEROV£a ; NOA No.: 07-1219.09 Expiration Date- 11/04/13 Approval ]Dale: 03/20/08 Page 19 of 19 MIA MIDADE mm BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) GAF Materials Corporation 1361 Alps Road Wayne, NJ 07470 MIAMI-DADE COUNTY, FLORIDA METRO-DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130-1563 (305) 375-2901 FAX (305) 375-2908 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The BCCO (In Miami Dade County) and/or the AHI (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the .manufacturer will incur the expense.of such testing and the.AHJ may immediately revoke, modify, or 'suspend the use of such product or material within their jurisdiction. BCCO reserves the right to revoke this acceptance, if it is determined by 13CCO that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Cobra Ridge Runner RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to. comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of pages 1 through 3. The submitted documentation was reviewed by Jorge L ce� _o C o: 07-0326.02ate:11/01/12ate: 11/01/07 Page 1 o£ 3 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: Ventilation Materials: Plastic TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Test Product Product Dimensions Specification Description Cobra Ridge Runner �,20' Length (Roll) TAS 100 Low profile attic ridge vent in roll form for 11.5" Width installation under ridge shingles. .7" Hieght EVIDENCE SUBMITTED: Test AgencyAdentifier Name Report Date ETC Laboratories, Inc. ASTM D 1929 ETC-07-718-19959.0 09/27/07 ASTM D635 ASTM D 2843 PRI Construction Materials ASTM G 26 GAF-138-02-06 02109/07 Technologies, Inc. TAS 100(A) GAF-139-02-04 02/09/07 LIMITATIONS: 1. Refer to applicable building codes for required ventilation. 2. All ridge vents in this NOA shall not be installed on roof mean heights greater than 33 feet. APPROVED APPLICATIONS: Slot: Determine whether the rafters are truss or ridgepole construction. Chalk a cut Iine of each. side of ridge. Cut a 1-3/a" (no ridge board) or 31/a" (ridge board) maximum slot along the apex of the roof by cutting 7/8" (no ridge board) or 1%" (ridge board) on each side of the ridge. The slot shall terminate 1 foot shorter at each end than the total length of ridge vent used. Installation: Place, center and conform the end of a piece of ridge vent at each end of slots. Mark the location of the end of the baffle. Strike a chalk Iine on both sides of the ridge to produce baffle alignment. Place vent sections centered over the slot using a chalk line. Place nails at pre -marked locations on the. Nails shall be mhumum 11 guage 23/11" corrosion resistant smooth shank roofing nails, a minimum 3/4" penetration into wood substrate is required. Ridge Shingle: Using nail lines provided on top of vent. NO cap shingles in place with a 5" exposure through vent using 2 nails. Nails shall be minimum 11 guage 23/s" corrosion resistant smooth shank roofing nails, a minimum 3/4" penetration into wood substrate is required. Net Free Area: Refer to manufacturers published literature Minimum Slope: 3:1.2 NOA No: 07-0326.02 Expiration Date:11/01112 Ci'_z Approval Date:11101/07 Page 2 of 3 Length .7" nWvirui�nt�xf rfarFtti►�nv.nrusn. END OF TMS ACCEPTANCE NOA No: 07-0326.02 Expiration Date:11101112 0- Approval Date:11/O1/07 Page 3 of 3