Loading...
HomeMy WebLinkAboutSUBMITTED PAPERS_2MIAMI- MADE M BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA MUMI-DADE COUNTY, FLORIDA METRO-DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130-1563 (305) 375-2901 FAX (305) 375-2908 CertainTeed Corporation (PA) 1400 Union Meeting Road Blue Bell, PA 19422 F E COPY SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review -Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). Ibis NOA shall not be valid after the expiration date stated -below. The BCCO (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BCCO reserves the right to revoke this acceptance, if it is determined by BCCO that this productor material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code and the HighVelocity Hurricane Zone of the Florida Building Code. DESCRIPTION: CertainTeed Modified Bitumen Roofing Systems Over Wood Decks LABELING: Fach unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the perfon-nance of this product. TERARNATION of this NOA will occur afterthe expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any oth ' er purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMIENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the reques.t of the Building Official. This NOA revises NOA No. 08-0227.09 and consists of pages I through 38. The submitted documentation was reviewed by Jorge L. Acebo. NOA No.: 08-0410.09 WRAMMADE ICVt� Expiration Date: 06119113 Approval Date: 11/20/08 Page 1 of 38 ROOFING ASSEAMLY APPRovAL Caft2ory: Sub-Cwteiyorr Deck Type: Maximum Desian Pressure Roofing APP/SBS Modified Bitumen Wood -60 psf TRADE NAmms OF PRODUCTS MANUFACTURED OR LABELED By ArPtIcANT: TABLE 1 Test Product ro U Dimensions Specffication Description Weatherffimpire Base 3611 x 65'10"; ASTM D 4601 Asphalt coated, fiberglass jAll Sheet Roll weight: 86 lbs. Type H reinforced base sheet. (2 squar�s) UL Type 15 Flex-l-Glagm Base Sheet 36" x 98'9"; Roll UL Type G2 Modified Bitumen coated weight: 90 lbs. ASTM D 4601, fiberglass base sheet. (3 squares) type 11 Flex-I-GlasIm FR Base 39/gif x 50'; Roll UL Type G2 Modified Bitumen coated Sheet weight: 90 lbs. ASTM D 4601, fiberglass base sheet. (1.5 squares) type II Flintglas@ Ply Sheet Type 36" x 1647'; Roll ASTM D 2178 Fiberglass, asphalt impregnated ply IV or VI weight: 40/55 lbs. Type IV or VI sheet. (5 squares) UL Type GI Flintlastic STA 391/8 if x 33'; Roll ASTM D 6222, Smooth surfaced APP Modified STA Plus 5.0 weight: 90 lbs. Grade S, Type 11 Bitumen membrane with non- (1 square) woven polyester mat reinforcement for torch application. GTA�FR 3 9 %" x 33'3 "; Roll ASTM D 6222, Granule surfaced APP Modified In GTA or c Dia on weight: 105. lbs. Grade G, Type 11 Bitumen membrane with non - (I square) woven polyester mat reinforcement for torch application. Flintlastic GTS 39 3/8" x 249"; Roll ASTM D 6164, Granule surfaced SBS Modified weight: 92 lbs. Grade G, Type 11 Bitumen membrane with non- (3/4 square) woven polyester mat reinforcement for torch applicaflon. Flintlastic GMS, '39 '/g" x 34'2"; Roll ASTM D 6164, Granule surfaced SBS Modified GMS Premium weight: 1001105 lbs. Grade G, Type IEI Bitumen membrane with non - (I square) woven polyester mat reinforcement for mop application. Flintlastic FR, 39 3/8" x 34'2"; Roll ASTM D 6164, Fire resistant, granule surfaced FR-P Premium weight: 105 lbs. Grade G, Type I SBS Modified Bitumen Membrane (I square) with non -woven polyester mat reinforcement for mop application. Flintlastic FR Cap Sheet 39 3/s" x 34'2"; Roll ASTM D 6163, Fire resistant, granule surfaced weight: 90 lbs. Grade G, Type I SBS Modified Bitumen membrane (I square) with fiberglass mat reinforcement for mop applications. NOA No.: 08-0410.09 Expiration Date: 06/19113 Approval Date: 11/20/08 Page 2 of 38 Flintlastic FR Cap T 39-3/8" x 34'2"; Roll ASTM D6163 Granule surfaced SBS Modified weight: 81lbs. Bitumen membrane with fiberglass (I square) mat reinforcement for torch application. Flintlastic FR Base T 39-3/8" x 33'; Roll ASTM 136163 Modified Bitumen, coated Weight: 81lbs. fiberglass base sheet for torch (1.0 squares) applica tion. Flintlastic FR Cap CoolStar 93 3 /: — -,, z, ; Koll Aa 1.Lyi D Ol 63 ' Fire resistant� granule surfaced weight: 90 lbs. 'Q13S Modified Bitumen membrane (I square) witi, -t-relass mat reinforcement for mop applications. %:- --red with reflecii � , CoolStar Coatyp­- Flintlastic FR Cap T 39 3/8" x 34'2"; Roll ASTM D 6163 Fire resistant, granule surfaceL. CoolStar weight: 90 lbs. SBS Modified Bitumen membrane (I square) with fiberglass mat reinforcement for mop applications. Covered with reflective CoolStar Coating. Flintlastic GTA, GTA-FR 3 9 '/8" x 33'3 "; Roll ASTM D 6222 Granule surfaced, APP Modified Coo]Star or Ffintlastic weight: 1.05 lbs. Bitumen membrane with non - Diamond GTA CoolStar square) woven polyester mat reinforcement for torch application. Covered with reflective CoolStar Coating. Flintlastic GTS Coo]Star 393/8 It x 24'9"; Roll ASTM D 6164 Granule surfaced, SBS Modified weight: 92 lbs. Bitumen membrane with non- (3 /4square) woven polyester mat reinforcement for torch application. Covered with reflective CoolStar Coating. Flintlastic GMS/GMS 39 3/8" x 34'2"; Roll ASTM D 6164 Granule surfaced SBS Modified Premium CoolStar weight: 1001105 lbs. Bitumen membrane with non - square) woven polyester mat reinforcement for mop application. Covered with reflective Co6lStar Coating. Flintlastic FR-P/FR-P 39 31s" x 34'2"; Roll ASTM D 6164 Fire resistant granule surfaced Premium Coo] Star weight: 105 lbs. SBS Modified Bitumen Membrane (I square) with non -woven polyester mat reinforcement for mop application. Covered with reflective CoolStar Coating. Covered with reflective CoolStar Coating. Flexiglas Premium Cap 960 36" x 34'6" ASTM D 6163, Granule surfaced SBS Modified CoolStar (I square) Grade G, Type I Bitumen membrane with fiberglass mat reinforcement for mop application. Covered with reflective CoolStar Coating. Flexiglas Premium Cap 960 36" x 34'6" ASTM D 6163, Granule surfaced SBS Modified (I square) Grade G, Type I Bitumen membrane with fiberglass mat reinforcement for mop applications. NOA No.: 08-0410.09 Expiration Date: 06119113 Approval Date: 11/20/08 Page 3 of 38 Ultra Poly SMS 36" x 6 * 4'4" ASTM D 6164, Smooth surfaced SBS Modified (2 squares) Grade S, Type I Bitumen Membrane with non- woven polyester mat reinforcement for mop applications. GlasBas6m Base Sheet 36 x 98'9"; Roll ASTM D 4601 Asphalt coated, fiberglass base weight: 69 lbs. UL Type G2 sheet. (3 squares) PolySMS Base Sheet 39 31sto x 64'4"; Roll ASTM D 6164 Modified Bitumen coated polyester weight: 90 lbs. base sheet. (2 squares) Yosemite@ Buffer Base 3611 x 32'10"; Roll ASTM D 3909 Mineral Surfaced fiberglass Sheet weight: 90 lbs. ASTM D 4897 reinforced buffer sheet. (I square) UL Type 3 0 Black Diamondrm Base 36" x 68'T'; Roll ASTM D 1970 Self -adhering fiberglass reinforced Sheet weight: 78 lbs. modified bitumen base sheet (2 squares) FlintglasS Mineral 36" X 32'10"; Roll ASTM D 3909 Asphalt impregnated and coated Surfaced Cap. Sheet Weight: 78 lbs. inorganic glass fiber surfaced with (I square) mineral granules used as the top ply in conventional built-up roof membranes. Flintglas@ Mineral 36" X j2'l 0"; Roll ASTM D 3909 Asphalt impregnated and coated Surfaced Cap Coo]Star Weight: 78 lbs. inorganic glass fiber surfaced with (I square) mineral granules used as the top ply in conventional built-up roof membranes. Covered with reflective CoolStar Coating. NOA No.: 08-0410.09 Expiration Date: 06119113 Approval Date: 11/20/08 Page 4 of 38 APPROVED INSULATIONS: TABLE2 Product Name Product Description Manufacturer (With Current NOA) KintBoard ISO Polyisocyanurate foam insulation CertainTeed ACFoam 11 Polyisocyanurate foam insulation Atlas Energy Products ISO95+ Polyisocyanurate foam insulation Firestone Building Products, Inc. High Density Wood Fiberboard Wood fiber insulation board generic Perlite Insulation Perlite insulation board generic Dens Deck, Dens Deck Prime Water resistant gypsum board G-P Gypsum Corp. H-Shield Polyisocyanurate foam insulation Hunter Panels ENRGY-3, UltraGard Gold, PSI-25 Polyisocyanurate foam insulation Johns Manville Fesco Board Expanded mineral. fiber insulation Johns Manville Multi -Max, FA Polyisocyanurate foam insulation RMax, Inc. APPRovED FASTENERS: TABLE3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) I . # 12 & # 14 Dekfast Insulation fastener SFS Intec Fastener 2. Dekfast Hex Plate Galvalume AZ50 steel plate 2 '/g" x 3 Y4" SFS, Intec 3. Olympic Fastener # 12 Insulation fastener OMG & #14 4. Olympic Standard 3 " round galvalume AZ50 3 round OMG steel plate 5. Insul-Fixx Fastener Insulation fastener for steel SFS Intec and wood decks 6. Insul-Fixx S Plate Galvalume AZ50 steel plate 3 round SFS Intee 7. Tru-Fast Fasteners Insulation fastener for wood The Tru-Fast Corp. and steel decks 8. Tru-Fast MP-3 Galvalume AZ50 steel plate 3 " round The Tru-Fast Corp. 9. Tru-Fast Plates Galvalume AZ55 steel plate 3 " round The Tru-Fast Corp. 10. Tru-Fast Plates Polyethylene plastic plate 3 " round The Tru-Fast Corp. NOA No.: 08-0410.09 Expiration Date: 06119113 MAM10WECOUNW Approval Date: 11/20/08 Q Page 5 of 38 d EviDENcE SUBMITTED-. Test Aaencv Applied Research Laboratories Factory Mutual Research Corporation Underwriters Laboratories, Inc. United States Testing Company, Momentum Technologies, Inc. . Name Physical Properties Current Insulation Fastening Requirements TAS 114/(FMRC 4470) UL 790 ASTM D 5147 ASTM D 4601 ASTM D 3909/ D 4897 TrinityjERD TAS 114 (J) TAS 114 (J) TAS 114 (J)/TAS 117 (B) TAS 117 (B) TAS 117 (B) TAS 114 (H) FM 4470, TAS 114 FM 4470, TAS 114 TAS I I 7.(B) ASTM Requirements WHIAMMPME C( 14W I �F!1294011411)=UNW Repo 28013 FMRC 1994 J.1. OWALAM RI 1656 974574 AX3lG8D AX3lG8C #3507.08.99-1 #3514.02LAB #3515.07.03 3503.10.06 06490.04.07-RI Letter 3533.01.06 3521.07.04 C8500SC.1 1.07 C10080.09.08 Date 06/02/87 01/01/95 03/23/96 07/13/87 06/03/88 09/05/08 09/05/08 04/18/01 11/11/02 07/22/03 10/10/06 06/27/07 04165106 01/06/06 07/29/04 11/30/07 09/04/08 NOA No.: 08-0410-09 Expiration Date: 06/19113 Approval Date: W20108 Page 6 of. 38 Membrane Type: APP MODIFIED Deck Type 1: Wood, Non -insulated Deck Description: Minimum 19 /32" thick plywood attached using wood screws spaced 6"o.c. at wood joists spaced maximum 24" o.c. System Type E(7): Base sheet mechanically fastened. All General and System Limitations apply. Base Sheet: One ply of Glas Base, Flex -I Glas Base, Flex -I Glas FR Base oQ I �Weather Empire Base Sheet mechanically fastened as detailed below. Fastening: Base sheet shall be lapped 4" and fastened with Simplex Mega Cap Nails spaced 9"o.c. in the lap and 9" o.c. in two staggered rows in the center of the sheet. Ply Sheet: (Optional) One ply of All Weather/Empire Base Sheet, GlasBase, Flex-I-GlasBase, Flex-1-Glas FR Base, P6lySMS or one or more plies of Flintglas Ply Sheet (Type IV) or Flintglas Premium Ply Sheet (Type VI) adhered to the base sheet in a full mopping of approved * asphalt applied within the EVT range and at a rate of 20-40 lbsJsq. or one ply of Black Diamond Base Sheet self adhered or Flintlastic STA torch adhered. Membrane: F1 Flintlastic Diamond GTA, Flintlastic Diamond GTA CoolStar, effintlastic GTAYlintlastic GTA CoolStar, Flintlastic GTA-FR CoolStar or GTA- PR_t_o_rcE_adNe_red to base or ply sheet. Surfacing: (Optional) Install one of the following: I . 4004b./sq. gravel or 300-lb./sq. slag in a flood coat of approved mopping asphalt at an application rate of 60 IbJsq. 2. Karnak 97, FlintCoat A-150, APOC 212 Fibrated Aluminum, Henry 520 Aluminum or Grundy. AL MB at an application rate of 1 VS. gal. /sq. Maximum Design Pressure: -60psf. (See General Limitation #7) NOA No.: 08-0410.09 Expiration Date: 06/19/13 Approval Date: 11/20/08 Page 36 of 38 Membrane Type: SBS MODIFIED Deck Type 1: Wood, Non -insulated Deck Description: Minimum 19/32" thick plywood attached using wood screws spaced Vo.c. at wood joists spaced maximum 24" o.c. System Type E(8): Base sheet mechanically fastened.' All General and System Limitations apply. Base Sheet: One ply of GlasBase, Flex -I Glas Base, Flex -I Glas FR Base or All Weather/Empire Base Sheet mechanically fastened as detailed below. Fastening: Base sheet shall be lapped 4" and fastened with Simplex Mega Cap Nails spaced 9" o.c. in the lap and 9" o.c. in two staggered rows in the center of the sheet. Ply Sheet: (Optional) One ply of All Weather/Empire Base Sheet� GlasBase, Flex-l-GlasBase, Flex-1-Glas FR Base, PolySMS or one or more plies of Flintglas Ply Sheet (Type IV) or Flintglas Premium Ply Sheet (Type VI) or Ultra Poly SMS adhered to the base sheet in a full mopping of approved asphalt applied within the EVT range. and at a rate of 20-40 lbsJsq. or one ply of Black Diamond Base Sheet (for use with a torched cap sheet only) self adhered. Membrane: One ply of Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic Premium GMS, Flintlas6o Premium GMS CoolStdr, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic; FR Cap Sheet Flintlastic FR Cap Sheet CoolStar, Flexiglas Premium Cap 960 or Ultra Poly SMS, Flintglas Mineral Surface Cap Sheet, Flintglas Mineral Surface Cap Sheet CoolStar adhered to ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbsJsq. or Flintlastic GTS, FHntlastic GTS CoolStar, Flintlastic; FR Cap T or Flintlastic FR Cap T CoolStar torch adhered to ply -sheet. Sarfacing: (Optional) Install -one of the following: 1. 400-lb./sq. gravel or 300-lbJsq. slag in a flood coat of approved mopping asphalt at an application rate of 60 lbJsq. 2. Karnak 97, FlintCoatA-150 orAPOC 212 Fibrated Aluminum at an application rate of 1.5 galJsq. Maximum Design Pressure: -60psf (See General Limitation #7) NOA No.: 08-0410.09 Expiration Date: 06119113 Approval Date: 11/20108 Page 37 of 38 WOOD DECK SYSTEM LEWTATIoNs: I.- A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. GENERAL LEVHTATIONS: I. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The.first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbsJsq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt panel size shall be 4'x 4'maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt 12" diameter circles ' 241, o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be At a minimum rate of 12 lbsJsq. Note: Spot attached systems shall be limited to ' a maximum design pressure of 45 psE 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F) value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field4ested, are below 275 lbf insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistan ' ce value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and comer areas shall, comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 1] 7. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 wiH not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS I I I and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and comers). Neither rational analysis,,nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended comers and comers). (When this limitation is specifically referred within this NOA, General Limitation #7 WM not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 913-72 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 08-0410.09 Expiration Date: 06119113 Approval Date: 1V20108 Page 38 of 38 Or.., T APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE Table Deck Application Type TRINITY! ERD Description Page 1A Wood New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 5-6 1B Wood New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 7 ic Wood New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 7 1D Wood New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover B-9 1E-1 Wood New, Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 10-11 1E-2 Wood New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 12-13 1F Wood New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 13 2A Steel or Conc. New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 14-15 2B Steel or Conc. New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 16-17 2C Steel or Conc. New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 18-19 3A Concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 20-24 3B Concrete New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 24 4A LWIC New or Reroof (Tear - Off) A-1 Bonded Insulation, Bonded Roof Cover 25-26 4B LWIC New, Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 27-29 SA CWF New or Reroof (Tear-Ofo A-1 Bonded Insulation, Bonded Roof Cover 30 5B CWF New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 31 5C CWF New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 32 5D CWF New, Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 32 6A Gypsum Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 33-34 6B Gypsum Reroof (Tear -Off) 6C Gypsum Reroof (Tear -Off) 6D Gypsum Reroof (Tear -Off) 7A Various Recover 7B Various Recover Exterior Research and Design, LLC. d/b/a Trinityl Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 35 C Mech. Attached Insulation, Bonded Roof Cover 36 E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 36 A-1 Bonded Insulation, Bonded Roof Cover 37-40 F Non -Insulated, Bonded Roof Cover 40 Lj Evaluation Report 3520.03.04-115 for FL2533-RS Revision 5: 04/26/2011 Appendix 1, Page 1 of 40 z�li INITY ERD The followinci notes apply to the systems outlined herein: 1. Roof decks shall be in accordance with FBC requirements to the satisfaction of the AHJ. Wind load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Unless otherwise noted, fasteners and stress plates for Insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements: > Wood Deck: OMG #14 Roofgrip with Flat Bottom Plate (Accutrac), OMG HD with OMG 3 in. Galvalume Steel Plate, Dekfast #14 with Hex Plate or 3" Round Insulation Plate, Tru-Fast HD with MP-3 Plates or FlintFast #14 Fastener with FlintFast 3" Insulation Plates. Minimum 3/4-Inch plywood penetration or minimum 1-inch wood plank embedment. > Steel Deck: OMG #12 or #14 Roofgrip with Recessed or Flat Bottom Plate (Accutrac), OMG #12 Standard or HD with OMG 3 in. Galvalume Steel Plate, Dekfast #12 or #14 with Hex Plate or 3" Round Insulation Plate, Tru-Fast DP or HD with MP-3 or FlintFast #12 or #14 Fastener with FlintFast 3" Insulation Plates. Minimum 3/4-inch steel penetration and engage the top flute of the steel deck. Concrete Deck: OMG #14 Roofgrip with Recessed or Flat Bottom Plate (Accutrac), OMG HD or CD-10 with OMG 3 in. Galvalume Steel Plate, Dekfast #14 or DekSpike with Hex Plate or 3" Round Insulation Plate, Tru-Fast HD or CF with MP-3 or FlintFast #14 Fastener with FlintFast 3" Insulation Plates. Minimum 1-inch embedment. Fasteners installed with a pilot hole in accordance with the fastener manufacturer's published installation instructions. 3. Unless otherwise noted, insulation may be any one layer or combination of polylsocyanurate, polystyrene, wood fiberboard, perlite, DensDeck, DensDeck Prime, DensDeck DuraGuard, SECUROCK Gypsum -Fiber Roof Board or SECUROCK Glass -Mat Roof Board that meets the QA requirements of F.A.C. Rule 9N-3 and Is documented as meeting FBC 1505.1 and, for foam plastic, FBC 2603.4.1 or 2603.8, when installed with the roof cover. 4. Minimum 200 psi, minimum 2-Inch thick lightweight Insulating concrete may be substituted for rigid insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the base sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck -listings. 5. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published instructions. > Hot asphalt (HA): Full coverage at 25-30 lbs/square > Ashland PlIodeck (A-PD): Continuous 3/4 Inch wide ribbons, 12-inch o.c. Ribbons of subsequent layers shall be > Dow Insta-Stlk (D-IS): > Dow Spray-N-Grip (D-SG): > Millennium Pourable Foam Insulation Adhesive (M-PFIA): > Millennium One Step Foarnable Adhesive (M-OSFA): > Millennium PG-1 Pump Grade Adhesive (M-PGI): > OMG OlyBond 500 or OlyBond Green (OB500): > 3M CR-20: perpendicular to those in the layer below. Continuous 3/4 to 1 inch wide ribbons, 12-Inch o.c. Full coverage Continuous 1/2 to 3/4-Inch wide ribbons, 12-Inch o.c. Continuous 1/4 to 1/2-inch wide ribbons, 12-inch o.c. Continuous 1/2 to 3/4-Inch wide ribbons, 12-inch o.c. Continuous 3/4-inch wide ribbons, 12-inch o.c. (PaceCart or SpotShot) Continuous 21/2 to 3-inch wide ribbons, 12-Inch o.c. (Note: TITESET may be used where CR-20 is referenced). > Note: When multiple layers(s) of insulation andlor coverboard are Installed in ribbon -applied adhesive, adhesive ribbons shall be staggered from layer -to -layer a distance of one-half the ribbon spacing. > Note: The maximum edge distance from the adhesive ribbon to the edge of the Insulation board shall be not less than one-haff the specified ribbons spacing. Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report 3520.03.04-RS for FL2533-RS Certificate of Authorization #9503 Revision 5: 04/26/2011 Prepared by: Robert Nierninen, PE-59166 Appendix 1, Page 2 of 40 ��TR"INITY ERD 6. Unless otherwise noted, all Insulations are flat stock or taper board of the minimum thickness noted. Tapered polylsocya n u rate at the following thickness lirritations may be substituted with the following Maximum Design Pressure (MDP) limitations: > Ashland Pliodeck (A-PD) @ 12-inch o.c. MDP -105.0 psf (Min. 1.0-inch thick) > Ashland Pliodeck (A-PD) @ 6-inch o.c. MDP -277.5 psf (Min. 1.0-inch thick) > Dow Insta-Stlk (D-IS): MDP -120.0 psf (Min. 1.0-inch thick) > Millennium One Step Foarnable Adhesive (M-OSFA): MDP -157.5 psf (Min. 1.0-inch thick) > Millennium PG-1 Pump Grade Adhesive (M-PGI): MDP -157.5 ps f (Min. 1.0-inch thick) > OMG OlyBond 500 or OlyBond Green (OB500): MDP -120.0 psf (Min. 1.0-inch thick) > OMG OlyBond 500 or OlyBoncl Green (OB500): MDP -90.0 psf (Min. 0.5-inch thick) > 3M CR-20: MDP -117.5 psf (Min. 1.0-inch thick) 7. Bonded polylsocyanurate insulation boards shall be maximum 4 x 4 ft. B. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117 and FM LPDS 1-29. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3 enhancements. 9. For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted. 10. For mechanically attached components over existing decks, fasteners shall be tested In the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI FX-1. 11. For existing substrates in a bonded recover installation, the existing roof surface shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the AHJ, as documented through field uplift testing In accordance with ASTM E907, FM LPDS 1-52 or ANSI/SPRI IA-1. 12. For Recover Applications using System Type D, the Insulation is optional; however, the existing roof system shall be suitable for a recover application. 13. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications. CertainTeed Flintlastic@ Modified Bitumen Components IkApplication Methods Reference Layer Material Application BP -AA Base Glasbase; All Weather/Empire Base; Flexiglas Base; Flintlastic Base 20 (Base and Ply sheets, Hot asphalt at 20-40 Asphalt -Applied) Ply Flintglas Ply Sheet Type IV; Flintglas Premium Ply Sheet Type VI lbs/square BP-AA2 Hot asphalt In 24-inch (Base, Spot -Asphalt- Base Yosemite Venting Base diameter spots In 30- Applied) grid pattern BP-AA3 -Inch Hot asphalt In 9-Inch (Base, Spot -Asphalt- Base Yosemite Venting Base I diameter spots In 24- Applied) Inch grid pattern Exterior Research and Design, LLC. d/b/a TrinitylERD Certificate of Authorization #9503 Prepared by: Robert Nleminen, PE-59166 Evaluation Report 3520.03.04-115 for FL2533-R5 Revision 5: 04/26/2011 Appendix 1, Page 3 of 40 TkINITY1 ERD CertalnTeed Flintlastic@ Modified Bitumen Components &Application Methods (continued) Reference Layer Material Application BP-CA2 Base/Ply Glasbase; All Weather/Empire Base; Flexiglas Base; Flintlastic Base 20 Henry #903 Adhesive at 1.5 gal/square Millennium Hurricane BP-CA3 Base/Ply Glasbase; All Weather/Empire Base; Flexiglas Base; Flintlastic Base 20 Force Membrane Adhesive, beads spaced 6-Inch o.c. Base Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base SBS-AA Ply Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base Hot asphalt at 20-40 Flintlastic Cap 30; Flintlastic Cap 30 CoolStar; Flintlastic FR Cap 30; Flintlastic FR Cap 30 CoolStar; Flintlastic FR- (SBS, Aspha It-Ap plied) lbs/square Cap P; Flintlastic FR-P CoolStar; Flintlastic Premium FR-P; Flintlastic Premium FR-P CoolStar; Flintlastic GMS; Flintlastic GMS CoolStar; Flintlastic Premium GMS; Flintlastic Premium GMS CoolStar Base Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base SBS-CA1 Ply Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base Karnak No. 81 at 1.5 Flintlastic Cap 30; Flintlastic Cap 30 CoolStar; Flintlastic FR Cap 30; FlIntlastic FR Cap 30 CoolStar; Flintlastic FR- (SBS, Cold -Applied) gal/square Cap P; Flintlastic FR-P CoolStar; Flintlastic Premium FR-P; FlIntlastic Premium FR-P CoolStar; Flintlastic GMS; Flintlastic GIVIS CoolStar; Flintlastic Premium GMS; Flintlastic Premium GIVIS Coolstar Base Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base SBS-CA2 Ply Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base Henry #903 Adhesive (SBS, Cold -Applied) Flintlastic Cap 30; Flintlastic Cap 30 CoolStar; Flintlastic FR Cap 30; Flintlastic FR Cap 30 CoolStar; FlIntlastic FR- at 1.5 gal/square. Cap P; FlIntlastic FR-P CoolStar; Flintlastic Premium FR-P; FlintlastIc Premium FR-P CoolStar; Flintlastic GMS; Flintlastic GMS CoolStar; Flintlastic Premium GMS; Flintlastic Premium GIVIS CoolStar Base Flintlastic Base 20; Flintlastic Poly SMS Base; FlIntlastic Ultra Poly SMS Base SBS-CA3 Ply FlIntlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base Millennium Hurricane Force Membrane Flintlastic Cap 30; Flintlastic Cap 30 CoolStar; FlIntlastic FR Cap 30; Flintlastic FR Cap 30 CoolStar; Flintlastic FR- (SBS, Cold -Applied) Adhesive, beads Cap P; Flintlastic FR-P CoolStar; Flintlastic Premium FR-P; FlIntlastic Premium FR-P CoolStar; Flintlastic GMS; spaced 6-Inch o.c. Flintlastic GMS CoolStar; Flintlastic Premium GMS; Flintlastic Premium GMS CoolStar Base FlIntlastic Base 20 T; Flintlastic FR Base 20 T SBS-TA Torch -Applied Ply Flintlastic Base 20 T; Flintlastic FR Base 20 T (SBS, Torch -Applied) Cap Flintlastic FR Cap 30 T; FlIntlastic FR Cap 30 T CoolStar; Flintlastic GTS; Flintlastic GTS CoolStar; Flintfastic GTS- FR; Flintlastic GTS-FR CoolStar; FlintClad APP-TA Base Flintlastic STA; Flintlastic STA Plus Cap Flintlastic STA; Flintlastic STA Plus; Flintlastic GTA; Flintlastic GTA CoolStar; Flintlastic GTA-FR; Flintlastic GTA-FR (APP, Torch -Applied) Torch -Applied CoolStar SBS-SA-H (SBS, Self-AdherIng, Base/Ply Black Diamond Base Sheet; Flintlastic Ultra Glass SA Self -Adhering Hybrid Systems) Base Flintlastic SA PlyBase; Flintlastic SA Mid Ply SBS-SA (SBS, Self -Adhering) Self -Adhering Ply FlIntlastic SA PlyBase; Flintlastic SA Mid Ply Cap 1 Flintlastic SA Cap; FlIntlastic SA Cap CoolStar; Flintlastic SA Cap FR; Flintlastic SA Cap FR CoolStar I Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report 3520.03.04-R5 for FL2533-R5 Certificate of Authorization #9503 Revision 5: 04/26/2011 Prepared by: Robert Nleminen, PE-59166 Appendix 1, Page 4 of 40 I V I, A, C-N \iTRINITY'ERD TABLE 1A: WOOD DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System Deck Anchor Sheet Base Insulation :J Top Insulation Roof Cover MDP Type Fasteners Attach Type___[ Attach Type Attach Base Piy cap NO. (See Note 1) � (Psf) SELF -ADHERING SYSTEMS: Min. 19/32-Inch Glasbase, All Weather 9-Inch o.c. In Min. 1.5-inch plywood at max. 24-Inch Empire, 32 ga., 1-5/8- Inch dia. tin 4-inch lap and 12-Inch a c In ACFoarn III Min. 1/4-Inch W-1 spans attached Flexiglas Base, Flintlastic Base caps with 11 two, equ;lly, FlintBoard ISO,ENRGY­ HA DensDeck with HA SBS-SA (Optional) SBS-SA -45.0* 6-Inch o.c. with 8d common or 20; Poly SMS; ga. annular ring shank nails spaced, staggered 3, H-Shleld or primed FlIntPrIme SA SBS-SA ring shank nails Ultra Poly SMS; center rows Multi -Max FA3 Yosemite Min. 19/32-inch plywood at Glasbase, All 32 ga., 1-5/8- 8-:nch o.c. In 3- nch lap and Min. 1.5-Inch HA full HA full max. 24-Inc h Weather Inch dia. tin 8-Inch o.c. In ACFoarn 11, coverage or Min. 1/4-inch coverage or W-2 spans attached Empire, Flexiglas Base, caps with 11 three, equally FlintBoard ISO, ENRGY-- OB500, M- OSFA, A-PD, D - DensDeck primed with OB500, M- OSFA, A-PD, D- SBS-SA (Optional) SBS-SA SBS-SA -52.5 6-Inch o.c. with 8d commo n or Poly SMS or ga. annular ring shank nails spaced, staggered 3, H-Shleld or IS or CR-20, 4- FlIntPrime SA IS or CR-20, 6- ring shank nails Ultra Poly SMS center rows Multl-Max FA3 inch o.c. Inch o.c. Min. 19/32-inch 8-Inch o.c. In plywood at 32 ga., 1-5/8- 3-Inch lap and Min. 1.5-inch max. 24-Inch Yosemite Inch dia. tin 8-inch o.c. in ACFoam III Min. 1/4-Inch W-3 spans attached Venting Base caps with 11 three, equally FlIntBoard ISO,ENRGY- HA DensDeck with HA S,BS-SA (Optional) SBS-SA -52.5 6-inch o.c. with Sheet ga. annular spaced, primed SBS-SA 8d common or ring shank nails staggered 3, H-Shleld or FlintPrIme SA ring shank nails center rows Multi -Max FA3 Min. 19/32-inch plywood at Glasbase, All 32 ga., 1-5/8- 8-inch o.c. In 3-Inch lap and (Optional) Min. 1.5-Inch HA full Min. 1/4-inch HA full max. 24-Inch Weather Empire, Inch dia. tin 8-inch o.c. In ACFoam III coverage or OB500, SECUROCK coverage or W-4 spans attached 6-Inch Flexiglas Base, caps with 11 three, equally FlInt8oard M- OSFA, A-PD, D- Gypsum -Fiber Roof Board OB500, M- OSFA, A-PD, D- SBS-SA (Optional) SBS-SA SBS-SA -60.0 o.c. with 8d ring shank Poly SMS or ga. annular ring shank nails spaced, staggered ISO,ENRGY_ 3, H-Shleld or IS or CR-20, 4- primed with IS or CR-20, 6- nails Ultra Poly SMS center rows Multi -Max FA3 Inch o.c. FlintPrime SA inch o.c. Min. 19/32-inch 8-Inch o.c. In (Optional) plywood at 32 ga., 1-5/8- 3-inch lap and Min. 1.5-inch Min. 1/4-Inch max. 24-Inch Yosemite Inch dia. tin 8-Inch o.c. in ACFoam III SECUROCK W-5 spans attached Venting Base caps with 11 three, equally FlIntBoard HA Gypsum -Fiber HA SBS-SA (Optional) SBS-SA -60.0 6-Inch o.c. with Sheet ga. annular spaced, ISO,ENRGY- Roof Board SBS-SA 8d ring shank ring shank nails staggered 3, H-Shleld or primed with I nails center rows Multi -Max FA3 FlintPrIme SA HYBRID SYSTEMS: Min. 19/32-Inch Glasbase, All Weather 9-Inch o.c. In Min. 1.5-inch plywood at Empire, 32 ga., 1-5/8- 4-inch lap and ACFoam III (Optional) max. 24-inch Flexiglas Base, Inch dia. tin 12-inch o.c. In FlintBoard BP -AA SBS-AA, W-6 spans attached Flintlastic Base caps with 11 two, equally ISO,ENRGY- HA None N/A SBS-SA-H SBS SBS-TA -45.0* 6-inch o.c. with 20; Poly SMS; ga. annular spaced, 3, H-Shleld or SBS-TA or or APP- 8d common or Ultra Poly SMS; ring shank nails staggered Multi -Max FA3 A PP -TA TA ring shank nails Yosemite center rows Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report 3520.03.04-115 for FL2533-RS Certificate of Authorization #9503 Revision 5: 04/26/2011 Prepared by: Robert Nlerninen, PE-59166 Appendix 1, Page 5 of 40 TABLE 1A: WOOD DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System Deck Anchor Sheet Base Insulation Top Insulation Roof Cover 1MDP Type Fasteners Attach Type Attach Type Attach---- Base Ply Cap No. (See Note 1) (psf) Min. 19/32-Inch 8-Inch o.c. In Min. 1.5-Inch plywood at Glasbase; 32 ga., 1-5/8- 3-Inch lap and ACFoarn II, (Optional) max. 24-inch Flintglas Inch dia. tin 8-Inch o.c. In FlintBoard BP -AA, SBS-AA, W-7 spans attached Premium Ply caps with 11 three, equally ISO,ENRGY- HA None N/A SBS-SA-H SBS-AA SBS-TA -60.0 6-inch o.c. with Sheet Type VI; ga. annular spaced, 3, H-Shleld or SBS-TA'or or APP- 8d ring shank Yosemite ring shank nails staggered Multi -Max FA3 APP-TA TA nails center rows CONVENTIONAL SYSTEMS: Min. 19/32-inch Glasbase, All Weather 9-Inch o.c. In Min. 1.5-Inch plywood at max. 24-inch Empire, 32 ga., 1-5/8- Inch dia. tin 4-inch lap and 12-Inch o.c. In ACFoarn II ' Min. 1/4-Inch DensDeck BP -AA, (Optional) BP-AA1 SBS-AA, W-8 spans attached Flexiglas Base, FlIntlastic Base caps with 11 two, equally FlintBoard ISO,ENRGY- HA primed with HA SBS-AA SBS_AA SBS-TA -45.0* 6-Inch o.c. with 20; Poly SMS; ga. annular spaced, 3, H-Shleld or ASTM D41 SBS-TAor APP-TA SBS-TA'or or APP- TA 8d common or Ultra Poly SMS; ring shank nails staggered Multi -Max FA3 primer APP-TA ring shank nails Yosemite center rows Min. 19/32-Inch plywood at Glasbase, All 32 ga., 1-5/8- 8- :nch o.c. In 3 - nch lap and Min. 1.5-inch HA full Min. 1/4-Inch HA full (Optional) max. 24-Inch Weather Empire, Inch dia. tin 8-Inch o.c. In ACFoarn 11, FlIntBoard coverage or OB500, M- DensDeck coverage or OB500, M- 130-AA, SBS-AA BP -AA, SBS-AA, SBS-TA W-9 spans attached 6-Inch o.c. w Ith Flexiglas Base, caps with 11 ga. annular three, equally spaced, ISO,ENRGY- OSFA, A-PD D- Pnrned with ASTM D41 OSFA, A-PD, D- SBS-TAor SBS_AA1 or APP- -52.5 8d common or Poly SMS or Ultra Poly SMS ring shank nails staggered 3, H-Shleld or Multi -Max FA3 IS or CR-20, 4- Inch primer IS or CR-20, 6- APP-TA SBS-TA or APP-TA TA ring shank nails center rows o.c. Inch o.c. Min. 19/32-Inch 8-Inch o.c. In Min. 1.5-Inch plywood at max. 24-Inch Yosemite 32 ga., 1-5/8- Inch dia. tin 3-Inch lap and 8-Inch o.c. In ACFoarn II, Min. 1/4-Inch DensDeck - BP -AA, (Optional) BP -AA, SBS-AA, W-10 spans attached Venting Base caps with 11 three, equally FlIntBoard ISO,ENRGY- HA primed with HA SBS-AA, SBS-AA, SBS-TA -52.5 6-inch o.c. with Sheet ga. annular spaced, 3, H-Shleld or ASTIVI D41 SBS-TA or APP-TA SBS-TA or or APP- 8d common or ring shank nails staggered Multi -Max FA3 primer APP-TA TA ring shank nails center rows Min. 19/32-Inch Glasbase, All 8-inch o.c. in (Optional) HA full HA full plywood at max. 24-Inch Weather 32 ga., 1-5/8- Inch dia. tin 3-inch lap and 8-Inch o.c. In Min. 1.5-Inch ACFoam II, coverage or Min. 1/4-Inch coverage or BP -AA, (Optional) SBS-AA, W-11 spans attached Empire, Flexlglas Base, caps with 11 three, equally FlintBoard OB500, M- OSFA, A-PD, D- SECUROCK Gypsum -Fiber OB500, M- OSFA, A-PD, D_ SBS-AA SBS-TAor BP -AA, SBS-AA, SBS-TA APP- -60.0 6-Inch o.c. with 8d ring shank Poly SMS or ga. annular ring shank nails spaced, staggered ISO,ENRGY- 3, H-Shield or IS or CR-20, 4- Roof Board IS or CR-20, 6- APP-TA SBS-TA or APP-TA or TA nails Ultra Poly SMS center rows Multi -Max FA3 Inch o.c. inch o.c. Min. 19/32-inch 8-inch o.c. in (Optional) plywood at max. 24-Inch Yosemite 32 ga., 1-5/8- Inch dia. tin 3-inch lap and 8-inch o.c. In Min. 1.5-inch ACFoarn II, Min. 1/4-inch BP -AA, (Optional) BP -AA SBS-AA, W-12 spans attached VentIng Base caps with 11 three, equally FlintBoard HA SECUROCK HA SBS-AA, S BS_ SBS-TA -60.0 6-Inch o.c. with Sheet ga. annular spaced, ISO,ENRGY- Gypsum -Fiber SBS-TA or S S- 'or or APP- 8d ring shank ring shank nails staggered 3, H-Shield or Roof Board APP-TA A P- TA nails center rows Multi -Max FA3 Exterior Research and Design, LLC. d/b/a TrInItyjERD Evaluation Report 3520.03.04-R5 for FL2533-RS Certificate of Authorization #9503 Revision 5: 04/26/2011 Prepared by: Robert Nierninen, PE-59166 Appendix 1, Page 6 of 40 L % TRINITYIERD TA:LE 1B: WOOD DECKS — NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER SYSTEM TYPE B: M CHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System Deck Base Insulation Layer I Top insulation Layer Roof Cover NO. (See Note 1) MDP (psf) Type Fasteners I A ch Type ttach Base Ply cap CONVENTIONAL SYSTEMS: Min. 23/32-Inch Min. 1.5-Inch ACFoam Min. 1/2-inch FM Approved Wood (Optional) SBS-AA, W-13 thick exterior grade II, FlIntBoard ISO, See Note 2 1 per 2 ft? Fiberboard, min. HA BP -AA or SBS- BP -AA, SBS- SBS-TA -45.0* plywood attached ENRGY 3, H-Shleld 3/4-Inch FM AA AA, SBS-TA or APP- per Code. Approved perlite or APP-TA TA Min. 1/4-Inch Min. 23/32-Inch Min. 1.5-inch ACFoam SECUROCK BP -AA, SBS- (Optional) SBS-AA, W-14 thick exterior grade 11, FlintBoard ISO, See Note 2 1 per 2 ft? Gypsum -Fiber HA AA, SBS-TA or BP -AA, SBS- SBS-TA -45.0* plywood attached ENRGY 3, H-Shleld Roof Board, APP-TA AA, SBS-TA or APP- per Code. DensDeck or or APP-TA TA DensDeck Prime I TABLE IC: WOOD DECKS — NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER SYSTEM TYPE Q MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System Deck Base Insulation Top Insulation Layer :T Roof Cover No. (See Note 1) Layer MDP (psf) Type Fasteners Attach ease Ply cap SELF -ADHERING SYSTEMS: Min. 19/32-Inch thick (Optional) One or more layers, any Min. 1/4-Inch 1 per (Optional) SBS- W-15 exterior grade plywood combination, loose DensDeck primed See Note 2 2 1.33 ft SBS-SA SA SBS-SA -45.0 attached per Code. laid with FlIntPrime SA Min. 1.5-Inch ACFoam Min. 19/32-Inch plywood (Optional) One or II, ENRGY 3, H- W-16 at max. 24-Inch spans more layers, any Shield, Multi -Max FA3 See Note 2 1 per SBS-SA (Optional) SBS- SBS-SA -60.0 attached 6-Inch o.c. with combination, loose or FlintBoard ISO 1.45 ft2 SA 8d ring shank nails laid primed with I I I FlintPrime SA CONVENTIONAL SYSTEMS: Min. 23/32-Inch thick (Optional) One or Min. 1/2-Inch FM Approved Wood (Optional) BP - SBS-AA, W-17 exterior grade plywood more layers, a ny combination, loose Fiberboard, min. 3/4- See Note 2 1 per 2 ft2 BP -AA or SBS- AA AA, SBS-AA, SBS-TA or APP SBS-TA or -45.0* attached per Code. laid Inch FM Approved TA APP-TA perlite Min. 23/32-Inch thick (Optional) One or more layers, any Min. 1/4-Inch SECUROCK Gypsum- 1 per 2 BP-AA1 S'BS- (Optional) BP - AA SBS-AA, SBS-AA, W-18 exterior grade plywood combination, loose Fiber Roof Board, See Note 2 ft2 AA, SBS-TA or SBS-TA or APP- SBS-TA or -45.0* attached per Code. laid DensDeck or APP-TA TA APP-TA DensDeck Prime Exterior Research and Design, LLC. d/b/a TrInItyjERD Evaluation Report 3520.03.04-RS for FL2533-RS Certificate of Authorization #9503 Revision 5: 04/26/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 7 of 40 K a �'j TRINITY1 ERD TABLE 1D: WOOD DECKS — NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER SYSTEM TYPE D: PRELIMINARILY ATTACHED INSULATION, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Deck Insulation Layer(s) Base or Anchor Sheet Roof Cover MDP Type Attach Base Fasteners Attach Ply cap No.. (See Note 1) (psf) SELF -ADHERING SYSTEMS: Min. 19/32-inch B-Inch o.c. at 3-Inch lap and 8- plywood at max Min. 1.5-Inch, Inch o.c. In two, equally spaced, W-19 24-inch spans One or more Prelim. Flintlastic SA See Note 2 staggered center rows SBS-SA SBS-SA -82.5 attach 6-Inch o.c. layers, any Attached NailBase Stress plates shall be primed using #8 wood combination with ASTM D41 primer or screws FlintPrime SA Min. 15/32-inch Flintfast 3 In. Insulation 6-Inch o.c. at 4-inch lap and 6- plywood at max Min. 1.5-inch, Plates with FlintFast #12 inch o.c. in three, equally W-20 24-Inch spans One or more Prelim. FlIntlastic SA or #14; Trufast MP3 spaced, staggered center rows. SBS-SA SBS-SA -97.5 attach 6-inch o.c. layers, any Attached NaIlBase with DP or HD; OMG 3 Stress plates shall be primed using #8 wood combination In. Round Metal Plates with ASTM D41 primer or screws with OMG #14 HD I'lintPrIme SA. Min. 15/32-Inch FlIntfast 3 In. Insulation 6-Inch o.c. at 4-inch lap and 6- plywood at max Min. 1.5-Inch, Plates with FlintFast #12 Inch o.c. In four, equally spaced, W-21 24-Inch spans One or more Prelim. Flintlastic SA or #14; Trufast M133 staggered center rows. Stress SBS-SA SBS-SA -127.5 attach 4-inch o.c. layers, any Attached NallBase with DP or HD; OMG 3 plates shall be primed with using #10 wood combination In. Round Metal Plates ASTM D41 primer or FlintPrime screws with OMG #14 HD SA. HYBRID SYSTEMS: Min. 15/32-inch Glasbase; FlIntfast 3 In. Insulation 6-inch o.c. at 4-inch lap and 6- plywood at max Min. 1.S-Inch, Flexiglas; Plates with FlIntFast #12 Inch o.c. In three, equally W-22 24-Inch spans One or more Prelim. Flintlastic Base or #14; Trufast MP3 spaced, staggered center rows. SBS-SA-H SBS-AA, SBS-TA or -97.5 attach 6-Inch o.c. layers, any Attached 20; Poly SMS with DP or HD; OMG 3 Stress plates shall be primed using #8 wood combination Base; Ultra Poly In. Round Metal Plates with ASTM D41 primer or APP-TA screws SMS Base with OMG #14 HD FIIntPrIme SA. Min. 19/32-Inch Glasbase; plywood at max Min. 1.5-inch, Flexlglas; 7-Inch o.c. at 3-Inch lap and 7- SBS-AA, W-23 24-Inch spans One or more Prelim. Flintlastic Base See Note 2 Inch o.c. in three, equally SBS-SA-H SBS-TA or -105.0 attach 6-inch o.c. layers, any Attached 20; Poly SMS spaced, staggered center rows APP-TA using #8 wood combination Base; Ultra Poly screws SMS Base Min. 15/32-inch Glasbase; FlIntfast 3 In. Insulation 6-Inch o.c. at 4-Inch lap and 6- plywood at max Min. 1.5-Inch, Flexiglas; Plates with FlintFast #12 Inch o.c. In four, equally spaced, W-24 24-Inch spans One or more Prelim. Flintlastic Base or #14; Trufast MP3 staggered center rows. Stress SBS-SA-H SBS-AA, SBS-TA or -127.5 attach 4-Inch o.c. layers, any Attached 20; Poly SMS with DP or HD; OMG 3 plates shall be primed with using #10 wood combination Base; Ultra Poly in. Round Metal Plates ASTM D41 primer or FlintPrime APP-TA screws SMS Base with OMG #14 HD SA. I Exterior Research and Design, LI-C. d/b/a TrInItyjERD Evaluation Report 3520.03.04-115 for FL2533-RS Certificate of Authorization #9503 Revision 5: 04/26/2011 Prepared by: Robert Nleminen, PE-59166 Appendix 1, Page 8 of 40 1 4 '�,Q'TR-jNjTy1ERD TABLE 1D: WOOD DECKS — NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER SYSTEM TYPE D: PRELIMINARILY ATTACHED INSULATION, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Deck I insulation Layer(s) I Base or Anchor Sheet Roof cover MD No. (See Note 1) Type Attach Base Fasteners Attach Ply Cap (PSO CONVENTIONAL SYSTEMS: Glasbase; All Min. 23/32-Inch thick exterior Min. 1.5-Inch, One or more Prelim. Weather/Empire Base; Flexiglas 12-Inch o.c. at 4-Inch lap and BP -AA, SBS- SBS-AA, W-25 grade plywood layers, any Attached Base; Flintlastic See Note 2 36-Inch o.c. In two, equally AA, SBS-TA SBS-TA or -30.0* attached per Code. combination Base 20; spaced, staggered center rows or APP-TA APP-TA Yosemite Glasbase; All Min. 23/32-Inch thick exterior Min. 1.5-Inch, One or more Prelim. Weather/Empire Base; Flexiglas 12-Inch o.c. at 4-Inch lap and BP -AA, SBS- SBS-AA, W-26 grade plywood layers, any Attached Base; Flintlastic See Note 2 24-inch o.c. In two, equally AA, SBS-TA SBS-TA or -45.0* attached per Code. combination Base 20; spaced, staggered center rows or APP-TA APP-TA Yosemite Min. 23/32-Inch thick exterior Min. 1.5-inch, One or more Prelim Poly SMS Base; 12-inch o.c. at 4-inch lap and BP -AA, SBS- SBS-AA, W-27 grade plywood layers, any Atta&d Ultra Poly SMS See Note 2 36-Inch o.c. In two, equally AA, SBS-TA SBS-TA or -45.0* attached per Code. combination Base spaced, staggered center rows or APP-TA APP-TA Min. 15/32-Inch Glasbase; Flexlglas; FlIntfast 3 in. Insulation 6-Inch o.c. at 4-Inch lap and 6- plywood at max Min. 1.5-inch, FlIntlastic Base Plates with FlintFast #12 Inch o.c. In three, equally (Optional) SBS-AA, W-28 24-Inch spans One or more Prelim. 20; Poly SMS or #14; Trufast MP3 spaced, staggered center rows. BP -AA, SBS_ SBS-TA or -97.5 attach 6-Inch o.c. layers, any Attached Base; Ultra Poly with DP or HD; OMG 3 Stress plates shall be primed AA, SBS-TA APP-TA using #8 wood combination SMS Base; In. Round Metal Plates with ASTM D41 primer or or APP-TA screws Yosemite with OMG #14 HD FIIntPrIme SA. Min. 19/32-Inch Glasbase; plywood at max 24-Inch spans Min. 1.5-inch, One or more Pr -ellm. Flexlglas; FlIntlastic Base 7-Inch o.c. at 3-Inch lap and 7- BP -AA, SBS- SBS-AA, W-29 attach 6-Inch o.c. layers, any Attached 20; Poly SMS See Note 2 Inch o.c. In three, equally AA, SBS-TA SBS-TA or -105.0 using #8 wood combination Base; Ultra Poly spaced, staggered center rows or APP-TA APP-TA screws SMS Base; Yosemite Min. 15/32-Inch Glasbase; Flexlglas- Flintfast 3 In. Insulation 6-Inch o.c. at 4-inch lap and 6- plywood at max Min. 1.5-inch, FlIntlastic Base Plates with FlintFast #12 Inch o.c. In four, equally spaced, (Optional) SBS-AA, W-30 24-Inch spans One or more Prelim 20; Poly SMS or #14; Trufast MP3 staggered center rows. Stress BP -AA, SBS- SBS-TA or -127.5 attach 4-Inch o.c. layers, any Atta&d Base; Ultra Poly with DP or HD; OMG 3 plates shall be primed with AA, SBS-TA APP-TA using #10 wood combination SMS Base; In. Round Metal Plates ASTM D41 primer or FIIntPrIme or APP-TA screws Yosemite with OMG #14 HD I SA. Exterior Research and Design, LLC. d/b/a TrInItylERD Evaluation Report 3520.03.04-RS for I'l-2533-115 Certificate of Authorization #9503 Revision 5: 04/26/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 9 of 40 . 1� TRINITY ERD TABLE 1E-1: WOOD DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Deck Base Sheet Roof Cover MDP Base Fasteners Attach Ply Cap No. (See Note 1) (Psf) SELF-ADHEPING SYSTEMS: Min. 15/32-inch plywood at -long, 6-Inch o.c. at 3-Inch lap and 6- W-31 max 24-inch spans attach 6- Inch o.c. using 8d ring shank FlIntlastic SA NallBase Min. I -Inch 12 ga. Simplex Metal Cap Nails Inch o.c. In four, equally spaced, SBS-SA SBS-SA -52.5 nails staggered center rows Min. 19/32-Inch plywood at max. 24-Inch spans attached 32 ga., 1-5/8-Inch dia. tin 8-Inch o.c. at 3-Inch lap and 8- W-32 6-Inch o.c. with Bd common Flintlastic SA NallBase caps with 11 ga. annular Inch o.c. in three, equally spaced, SBS-SA SBS-SA -52.5 nails ring shank nails staggered center rows Min. 19/32-Inch plywood at max. 24-Inch spans attached 6- 32 ga., 1-5/8-Inch dia. tin 8-Inch o.c. at 4-Inch lap and 8- W-33 inch o.c. with 8d ring shank Flintlastic SA NailBase caps with 11'ga. annular Inch o.c. in three, equally spaced, SBS-SA SBS-SA -60.0 nails or 4-Inch o.c. with 8d ring shank nails staggered center rows common nails Min. 19/32-Inch plywood at 32 ga., 1-5/8-Inch dia. tin 6-Inch o.c. at 3-Inch lap and 6- W-34 max 24-Inch spans attach 6- Flintlastic SA NallBase caps with 11 ga. annular Inch o.c. In four, equally spaced, SBS-SA SBS-SA -75.0 Inch o.c. using #8 wood screws ring shank nails staggered center rows Min. 19/32-Inch plywood at 32 ga., 1-5/8-inch dia. tin 4-inch o.c. at 3-Inch lap and 4- W-35 max 24-Inch spans attach 6- Flintlastic SA NallBase caps with 11 ga. annular Inch o.c. In four, equally spaced, SBS-SA SBS-SA 105.0 Inch o.c. using #8 wood screws ring shank nails staggered center rows HYBRID SYSTEMS: Glasbase; Flexlglas; Min. 19/32-Inch thick exterior FlintlastIc Base 20; All 32 ga., 1-5/8-Inch dia. tin 9-Inch o.c. at 4-Inch lap and 12- SBS-AA, W-36 grade plywood attached per Weather / Empire Base; caps with 11 ga. annular Inch o.c. In two, equally spaced, SBS-SA-H SBS-TA or -45.0* Code. Poly SMS Base; Ultra Poly ring shank nails staggered center rows APP-TA SMS Base Min. 15/32-Inch plywood at Glasbase; Flexiglas; W-37 max 24-Inch spans attach 6- FlIntlastic Base 20; All Weather / Empire Base; Min. I -Inch long 12 ga 6-Inch o.c. at 3-Inch lap and 6- inch o.c. In four, equally spaced, SBS-SA-H SBS-AA, SBS-TA or -52.5 Inch o.c. using 8d ring shank nails Poly SIVIS Base; Ultra Poly Simplex Metal Cap Nall; staggered center rows APP-TA SMS Base Min. 19/32-inch plywood at max 24-Inch spans attach 6- Glasbase; Flexiglas; FlIntlastic Base 20; Poly 32 ga., 1-5/8-Inch dia. tin 8-inch o.c. at 4-inch lap and 8- SBS-AA, W-38 Inch o.c. using 8d common SMS Base; Ultra Poly SMS caps with 11 ga. annular Inch o.c. In three, equally spaced, SBS-SA-H SBS-TA or -52.5 nails Base ring shank nails staggered center rows APP-TA Min. 19/32-inch plywood at max 24-inch spans attach 6- Glasbase; Flexiglas; Fllntlastic Base 20; Poly 32 ga., 1-5�8-lnch dia. tin 8-Inch o.c. at 4-Inch lap and 8- SBS-AA, W-39 inch o.c. using 8d ring shank SMS Base; Ultra Poly SMS caps with 11 ga. annular Inch o.c. In three, equally spaced, SBS-SA-H SBS-TA or -60.0 nails Base ring shank nails I staggered center rows APP-TA Exterior Research and Design, LLC. d/b/a TrInItyjERD Evaluation Report 3520.03.04-RS for FL2533-R5 Certificate of Authorization #9503 Revision 5: 04/26/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 10 of 40 I gumn 44, -Nm TRINITY I ERD TABLE 1E-1: WOOD DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Deck Base Sheet Roof Cover MDP Base Fasteners Attach Ply Cap No. (See Note 1) (Psf) Min. 19/32-inch plywood at Glasbase; Flexiglas; Flintlastic Base 20, Poly 32 ga., 1-5/8-Inch dia. tin 6-Inch o.c. at 4-Inch lap and 6- SBS-AA, W-40 max 24-Inch spans attach 6- SMS Base; Ultra Poly SMS caps with 11 ga. annular Inch o.c. In four, equally spaced, SBS-SA-H SBS-TA or -82.5 Inch o.c. using #8 wood screws Base ring shank nails staggered center rows APP-TA Min. 19/32-Inch plywood at Glasbase; Flexlglas; FlIntlastic Base 20; Poly. 32 ga., 1-5/8-Inch dia. tin 4-inch o.c. at 3-Inch lap and 4- SBS-AA, W-41 max 24-Inch spans attach 6- SIVIS Base; Ultra Poly SMS caps with 11 ga. annular Inch o.c. In four, equally spaced, SBS-SA-H SBS-TA or -105.0 Inch o.c. using #8 wood screws Base ring shank nails staggered center rows APP-TA CONVENnONAL SYSTEMS: Glasbase; Flexiglas; Min. 19/32-Inch thick exterior Flintlastic Base 20; All 32 ga., 1-5/8-Inch dia. tin 9-Inch o.c. at 4-Inch lap and 12- BP -AA, SBS- SBS-AA, W-42 grade plywood attached per Weather/ Empire Base; caps with 11 ga. annular Inch o.c. In two, equally spaced, AA, SBS-TA or SBS-TA or -45.0* Code. Poly SMS Base; Ultra Poly ring shank nails staggered center rows APP-TA APP-TA SMS Base; Yosemite Min. 15/32-Inch plywood at Glasbase; Flexlglas; FlIntlastic Base 20; All 6-inch o.c. at 3-inch lap and 6- (Optional) BP- SBS-AA, W-43 max 24-Inch spans attach 6- Inch -o.c. using Bd ring shank Weather / Empire Base; Min. 1-Inch long, 12 ga. Simplex Metal Cap Nails Inch o.c. In four, equally spaced, AA, SBS-AA, SBS-TA or SBS-TA or -52.5 nails Poly SMS Base; Ultra Poly staggered center rows APP-TA APP-TA SMS Base; Yosemite Min. 19/32-Inch plywood at max 24-inch spans attach 6- Glasbase; Flexlglas; FlIntlastic Base 20; Poly 32 ga., 1-5/ 8-inch dia. tin 8-Inch o.c.- at 4-Inch lap and 8- BP -AA, SBS- SBS-AA, W-44 Inch o.c. using 8d common SMS Base; Ultra Poly SMS caps with 11 ga. annular inch o.c. In.three, equally spaced, AA, SBS-TA or SBS-TA or -52.5 nails Base; Yosemite ring shank nails staggered center rows APP-TA APP-TA Min. 19/32-Inch plywood at max 24-Inch spans attach 6- Glasbase; Flexiglas; Flintlastic Base 20; Poly 32 ga., 1-5/8-Inch dia. tin 8-Inch o.c. at 4-Inch lap and 8- BP -AA, SBS- SBS-AA, W-45 inch o.c. using 8d ring shank SMS Base; Ultra Poly SMS caps with 11 ga. annular Inch o.c. In three, equally spaced, AA, SBS-TA or SBS-TA or -60.0 nails as , semite ring shank nails staggered center rows APP-TA APP-TA /W-46 Min. 19/32-Inch plywood at Qlasb se>IexIgIas; Flintlastic Base 20; Poly 32 ga., 1-5/8-inch dIa. tin 6-Inch o.c. at 4-inch lap and 6- BP -AA, SBS- SBS-AA, max 24-Inch spans attach 6- SMS Base; Ultra Poly SMS caps with 11 ga. annular Inch o.c. In four, equally spaced, _AA—SA5-TA o r SBS-TA or -82.5 Inch o.c. using #8 wood screws Base; Yosemite ring shank nails staggered center rows -TA AP-TZ� Min. 19/32-Inch plywood at Glasbase; Flexlglas; Flintlastic Base 20; Poly 32 ga., 1-5/8-inch dia. tin 4-Inch o.c. at 3-Inch lap and 4- BP -AA, SBS- SBS-AA, W-47 I max 24-Inch spans attach 6- SMS Base; Ultra Poly SMS caps with 11 ga. annular Inch o.c. In four, equally spaced, AA, SBS-TA or SBS-TA or -105.0 I Inch o.c. using #8 wood screws Base; Yosemite ring shank nails . staggered center rows . APP-TA I APP-TA I I Exterior Research and Design, LLC. d/b/a TrInityjERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 F, � � Evaluation Report 3520.03.04-115 for FL2533-RS Revision 5: 04/26/2011 Appendix 1, Page 11 of 40 1 0 1 \,JTR1N1TYj1ERD TABLE 1E-2: WOOD DECKS — NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Deck Base Sheet Roof Cover MD Base Fasteners Attach Ply cap No. (See Note 1) (Psf) SELF -ADHERING SYSTEMS: Min. 19/32-Inch plywood at 8-Inch o.c. at 3-inch lap and 8-Inch o.c. max 24-Inch spans attach Flintlastic SA In two, equally spaced, staggered W-48 6-Inch o.c. using #8 wood NallBase See Note 2 center rows. Stress plates shall be SBS-SA SBS-SA -82.5 primed with ASTM D41.primer or screws FlintPrime SA Min. 15/32-Inch plywood at FlIntfast 3 In. Insulation 6-Inch o.c. at 4-Inch lap and 6-Inch o.c. max 24-Inch spans attach FlIntlastic SA Plates with FlintFast #12 or In three, equally spaced, staggered W-49 6-Inch o.c. using #8 wood NallBase #14; Trufast MP3 with DP or center rows. Stress plates shall be SBS-SA SBS-SA -97.5 HD; OMG 3 In. Round Metal primed with ASTM D41 primer or screws Plates with OMG #14 HD FlintPrime SA. Min. 15/32-Inch plywood at Flintfast 3 In. Insulation 6-Inch o.c. at 4-Inch lap and 6-Inch o.c. max 24-Inch spans attach Flintlastic SA Plates with FlintFast #12 or in four, equally spaced, staggered W-50 4-Inch o.c. using #10 wood NallBase #14; Trufast MP3 with DP or center rows. Stress plates shall be SBS-SA SBS-SA -127.5 HD; OMG 3 In. Round Metal primed with ASTM D41 primer or screws I I I Plates with OMG #14 HD FlIntPrime SA. HYBRID SYSTEMS: Min. 15/32-Inch plywood at Glasbase; Flexlglas; Flintfast 3 In. Insulation 6-inch o.c. at 4-Inch lap and 6-Inch o.c. max 24-Inch spans attach Flintlastic Base 20; Plates with FlintFast #12 or In three, equally spaced, staggered SBS-AA, W-51 6-inch o.c. using #8 wood Poly SMS Base; Ultra #14; Trufast MP3 with DID or center rows. Stress plates shall be SBS-SA-H SBS-TA or -97.5 screws Poly SMS Base HD. OMG 3 In. Round Metal primed with ASTM D41 primer or APP-TA Plaies with OMG #14 HD FlIntPrIme SA. Min. 19/32-Inch plywood at Glasbase; Flexiglas; 7-Inch o.c. at 3-Inch lap and 7-Inch o.c. SBS-AA, W-52 max 24-Inch spans attach 6-Inch o.c. using #8 wood Flintlastic Base 20; Poly SMS Base; Ultra See Note 2 In three, equally spaced, staggered SBS-SA-H SBS-TA or -105.0 screws Poly SMS Base center rows APP-TA Min. 15/32-Inch plywood at Glasbase; Flexiglas; Flintfast 3 In. Insulation 6-Inch o.c. at 4-Inch lap and 6-Inch o.c. max 24-inch spans attach FlIntlastic Base 20; Plates with FlIntFast #12 or In four, equally spaced, staggered SBS-AA, W-53 4-Inch o.c. using #10 wood Poly SMS Base, Ultra #14; Trufast M133 with DP or center rows. Stress plates shall be SBS-SA-H SBS-TA or -127.5 screws Poly SMS Base HD; OMG 3 In. Round Metal primed with ASTM D41 primer or APP-TA Plates with OMG #14 HD FlIntPrime SA. CONVENTIONAL SYSTEMS: Glasbase; All Min. 23/32-inch thick Weather/Empire 12-Inch o.c. at 4-Inch lap and 36-Inch BP -AA, SBS-AA, SBS-AA, W-54 exterior grade plywood Base; Flexiglas See Note 2 o.c. In two, equally spaced, staggered SBS-TA or APP- SBS-TA or -30.0* attached per Code. Base; Flintlastic center rows TA APP-TA Base 20; Yosemite Exterior Research and Design, LLC. d/b/a TrInItyjERD Evaluation Report 3520.03.04-R5 for FL2533-RS Certificate of Authorization #9503 Revision 5: 04/26/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 12 of 40 11 4 ITRINITYIERD TABLE 1113-2: WOOD DECKS — NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Deck Base Sheet Roof Cover MDP Base Fasteners Attach Ply Cap No. (See Note 1) (Psf) Glasbase; All Min. 23/32-Inch thick Weather/Empire 12-inch o.c. at 4-Inch lap and 24-Inch BP -AA, SBS-AA, SBS-AA, W-55 exterior grade plywood Base; Flexiglas See Note 2 o.c. In two, equally spaced, staggered SBS-TA or APP- SBS-TA or -45.0* attached per Code. Base; FlIntlastic center rows TA APP-TA Base 20; Yosemite Min. 23/32-inch thick Poly SMS Base; Ultra 12-inch o.c. at 4-Inch lap and 36-Inch BP -AA, SBS-AA, SBS-AA, W-56 exterior grade plywood Poly SMS Base See Note 2 o.c. in two, equally spaced, staggered SBS-TA or APP- SBS-TA or -45.0* attached per Code. center rows TA APP-TA Min. 15/32-inch plywood at Glasbase; Flexlglas; Flintfast 3 In. Insulation (Optional) BP - max 24-Inch spans attach Flintlastic Base 20; Plates with FlIntFast #12 or 6-inch o.c. at 4-Inch lap and 6-Inch o.c. AA, SBS-AA, SBS-AA, W-57 6-Inch o.c. using #8 wood Poly SMS Base; Ultra #14; Trufast MP3 with DP or in three, equally spaced, staggered SBS-TA or APP- SBS-TA or -97.5 Poly SMS Base; HID; OMG 3 In. Round Metal center rows TA APP-TA screws Yosemite Plates with OMG #14 HD Min. 19/32-Inch plywood at Glasbase; Flexiglas; FlIntlastic Base 20; 7-Inch o.c. at 3-Inch lap and 7-inch o.c. BP -AA, SBS-AA, SBS-AA, W-58 max 24-Inch spans attach 6-Inch o.c. using #8 wood Poly SMS Base; Ultra See Note 2 In three, equally spaced, staggered SBS-TA or APP- SBS-TA or -105.0 Poly SMS Base; center rows TA APP-TA screws Yosemite Min. 15/32-Inch plywood at Glasbase; Flexlglas; Flintfast 3 In. Insulation (Optional) BP - max 24-Inch spans attach Flintlastic Base 20; Plates with FlIntFast # 12 or 6-Inch o.c. at 4-inch lap and 6-Inch o.c. AA, SBS-AA, SBS-AA, W-59 4-Inch a.c. using #10 wood Poly SMS Base; Ultra #14; Trufast MP3 with DID or In four, equally spaced, staggered SBS-TA or APP- SBS-TA or screws Poly SMS Base; HD; OMG 3 In. Round Metal center rows TA APP-TA Yosemite Plates with OMG #14 HD TABLE IF: WOOD DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE F: NON -INSULATED, BONDED ROOF COVER System Deck Roof Cover No. (See Note 1) Primer MDP (Psf) Base Ply Cap Min. 19/32-Inch plywood at max W-60 24-Inch spans attach 6-Inch o.c. FIIntPrIme SA SBS-SA (Optional) SBS-SA SBS-SA -127.5 using #8 wood screws I Exterior Research and Design, LLC. d/b/a TrInItyjERD Evaluation Report 3520.03.04-R5 for FL2533-RS Certificate of Authorization #9503 Revision 5: 04/26/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 13 of 40 ,-- N/­ \,/TRINITY! ERD TABLE 2A: STEEL OR CONCRETE DECKS — NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System Deck Base Insulation Layer Top Insulation Layer Roof Cover No. (See Note 1) MDP (psf) Fastener Type Attach 7 __:F� ype Attach _F_ I Base piy cap SELF -ADHERING SYSTEMS: Min 22 ga., type B, Min. 2-Inch ACFoam Min. 1/4-inch HA, D-IS, M- S-1 GQe 33 steel or min. 2,500 psi II, FlintBoard, ENRGY See Note 2 1 per 4 ft2 SECUROCK Gypsum -Fiber OSFA, OBSOO or SBS-SA (Optional) SBS-SA SBS-SA -37.5* structrual concrete 3 or H-Shleld Roof Board CR-20 Min. 22 ga., type B, Min. 1.5-inch ACFoam Min. 1/4-Inch HA, D-IS, M- S-2 Grade 33 steel or II, FlintBoard, ENRGY See Note 2 1 per 2 ft2 SECUROCK OSFA, OB500 or SBS-SA (Optional) SBS-SA -45.0* min, 2,500 psi 3 or H-Shield Gypsum -Fiber CR-20 SBS-SA structrual concrete Roof Board CONVENTIONAL SYSTEMS: Min. 22 ga., type B, Min. 2-Inch ACFoam Min. 1/4-inch HA, D-15, M- BP -AA, SBS- (Optional) SBS-AA, S-3 Grade 33 steel or II, FlIntBoard, ENRGY See Note 2 1 per 4 ft2 SECUROCK OSFA, OB500 or AA, SBS-TA or BP -AA, SBS- SBS-TA -37.5* min. 2,500 psi 3 or H-Shleld Gypsum -Fiber CR-20 APP-TA AA, SBS-TA or APP- structrual concrete Roof Board or APP-TA TA Min. 22 ga., type B, Min. 1.5-inch ACFoam Min. 1/2-inch FM Approved Wood (Optional) SBS-AA, S-4 Grade 33 steel or II, FlintBoard, ENRGY See Note 2 1 per 2 ft2 Fiberboard, min. HA BP -AA or SBS- BP -AA, SBS- SBS-TA -45.0* min. 2,500 psi 3 or H-Shield -Y4-inch FM AA AA, SBS-TA or APP- structrual concrete Approved perlite. or APP-TA TA Min. 22 ga., type B, Min. 1.5-inch ACFoam Min. 1/4-Inch BP -AA, SBS_ (Optional) SBS-AA, S-5 Grade 33 steel or II, FlintBoard, ENRGY See Note 2 1 per 2 ft2 DensDeck or HA AA, SBS-TA or BP -AA, SBS- SBS-TA -45.0* min. 2,500 psi 3 or H-Shield DensDeck Prime APP-TA AA, SBS-TA or APP- structrual concrete or APP-TA TA Min. 22 ga., type B, Min. 1.5-inch ACFoarn Min. 1/4-Inch HA, D-IS, M- BP -AA, SBS_ (Optional) SBS-AA, S-6 Grade 33 steel or min. 2,500 psi II, FlintBoard, ENRGY See Note 2 1 per 2 ft? SECUROCK Gypsum -Fiber OSFA, OB500 or AA, SBS-TA or BP -AA, SBS- AA, SBS-TA SBS-TA or APP- -45.0* structrual concrete 3 or H-Shield Roof Board CR-20 APP-TA or APP-TA TA Min. 22 ga., type B, Min. 2-Inch ACFoam Min. 1/2-inch FM Approved Wood (Optional) SBS-AA, S-7 Grade 33 steel or II, FlintBoard, ENRGY See Note 2 1 per 3.2 ft2 Fiberboard, min. HA BP -AA or SBS- BP -AA, SBS- SBS-TA -45.0* min. 2,500 psi 3 or H-Shield 3/4-inch FM AA AA, SBS-TA or APP- structrual concrete Approved perlite. or APP-TA TA Min. 22 ga., type B, Min. 2-Inch ACFoam Min. 1/4-inch BP -AA, SBS- (Optional) SBS-AA, S-8 Grade 33 steel or II, FlintBoard, ENRGY See Note 2 1 per 3.2 ft2 DensDeck or HA AA, SBS-TA or BP -AA, SBS- SBS-TA -45.0* min. 2,500 psi 3 or H-Shield DensDeck Prime APP-TA AA, SBS-TA or APP- structrual concrete or APP-TA TA Min. 22 ga., type B, Min. 1.5-Inch ACFoam Min. 3/4-inch (Optional) SBS-AA, S-9 Grade 33 steel or II, FlintBoard, ENRGY See Note 2 I per 1.33 FescoBoard HA BP -AA or SBS- BP -AA, SBS- SBS-TA -52.5 min. 2,500 psi 3 or Mult-Max FA3 ft2 (homogeneous) AA AA, SBS-TA or APP- structrual concrete or APP-TA I TA Exterior Research and Design, LLC. d/b/a*Trinity I ERD Evaluation Report 3520.03.04-RS for FL2533-RS Certificate of Authorization #9503 Revision 5: 04/26/2011 Prepared by: Robert Nlemlnen, PE-59166 Appendix 1, Page 14 of 40 1jT6JN1TY ERD TABLE ZA: STEEL OR CONCRETE DECKS — NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System Deck Base Insulation Layer Top Insulation Layer Roof Cover No. (See Note 1) Type Fasteners Attach Type Attach Base Ply Cap MDP (psf) Min. 22 ga., type B, Min. 2-inch ACFoarn Min. 1/4-inch HA, D-IS, M- BP --AA, SBS- (Optional) SBS-AA, S-10 Grade 33 steel or II, FlintBoard, ENRGY See Note 2 1 per 1.6 ft2 SECUROCK OSFA, OB500 or AA, SBS-TA or BP -AA, SBS- SBS-TA -60.0 min. 2,500 psi 3 or H-Shleld Gypsum -Fiber CR-20 APP-TA AA, SBS-TA or APP- structrual concrete Roof Board or APP-TA TA Min. 22 ga., type B, Min. 1.5-inch ACFoam Min. 1/2-inch (Optional) SBS-AA, S-11 Grade 33 steel or II, FlintBoard, ENRGY See Note 2 'I per 1.33 Structodek High HA BP -AA or SBS- BP -AA, SBS- SBS-TA -67.5 min. 2,500 psi 3 or Mult-Max FA3 ft2 Density AA AA, SBS-TA or APP- structrual concrete I I Fiberboard I I or APP-TA TA Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report 3520.03.04-R5 for FL2533-R5 Certificate of Authorization #9503 Revision 5: 04/26/2011 Prepared by: Robert Nleminen, PE-59166 Appendix 1, Page 15 of 40 -J TRINITY I ERD TABLE 2B: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER SYSTEM TYPE C. MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System Deck Base Insulation Top Insulation Layer I Roof Cover No. (See Note 1) Layer(s) MBP (Psf) Type Fasteners I Attach _T Base Ply Cap SELF -ADHERING SYSTEMS: Min. 22 ga., type B, (Optional) One or Min. 1/4-inch SECUROCK S-12 Grade 33 steel or min. more layers , any Gypsum -Fiber Roof See Note 2 1 per 3.2 ft2 SBS-SA (Optional) SBS- SBS-SA -30.0* 2,500 psi structrual combination, loose Board SA concrete laid Min. 22 ga., type B, (Optional) One or Min. 3/8-Inch S-13 Grade 33 steel or min. more layers, any SECUROCK Gypsum- See Note 2 1 per 2.7 ft2 SBS-SA (Optional) SBS- SBS-SA -45.0* 2,500 psi structrual combination, loose Fiber Roof Board SA concrete laid Min. 22 ga., type B, (Optional) One or Min. 1/4-inch DensDeck S-14 Grade 33 steel or min. more layers , any primed with FlintPrime See Note 2 1 per 2 1.33 SBS-SA (Optional) SBS- SBS-SA -45.0 2,500 psi structrual combination, loose SA ft SA concrete laid Min. 22 ga., type B, Min. 1.5-inch, One S-15 Grade 33 steel at max. 6 or more layers, any Min. 1/4-inch DensDeck See Note 2 1 per 1 33 SBS-SA (Optional) SBS- SBS-SA -52.5 ft spans or min. 2,500 combination, loose DuraGuard ft2 SA psi structrual concrete laid HYBRID SYSTEMS: Min. 22 ga., type B, (Optional) One or (Optional) BP - S-16 Grade 33 steel or min. more layers, any Min. 1/4-inch DensDeck; See Note 2 1 per 2 ft2 SBS-SA-H AA, SBS-AA, SBS-AA, SBS-TA or -30.0* 2,500 psi structrual combination, loose DensDeck Prime SBS-TA or APP- concrete laid TA APP-TA Min. 22 ga., type B, (Optional) One or Min. 1.5-inch ACFoam S-17 Grade 33 steel or min. more layers, any II, FlintBoard ISO, See Note 2 I per 133 SBS-SA-H (Optional) BP -AA SBS-AA -52.5 2,500 psi structrual combination, loose ENRGY 3 or Multi -Max ft2 or SBS-AA concrete laid FA3 Min. 22 ga., type B, (Optional) One or Min. 1.5-inch ACFoam S-18 Grade 33 steel or min. more layers, any II, FlintBoard ISO, See Note 2 I per 1.33 SBS-SA-H (Optional) SBS- SBS-TA or -82.5 2,500 psi structrual combination, loose ENRGY 3 or Multl-Max ft2 TA or APP-TA APP-TA concrete laid FA3 CONVENTIONAL SYSTEMS: Min. 22 ga., type B, (Optional) One or (Optional) BP- S-19 Grade 33 steel or min. more layers, any Min. 3/4-inch FM See Note 2 1 per 2.67 BP -AA, SBS- AA, SBS-AA, SBS-AA, SBS-TA or -30.0* 2,500 psi structrual combination, loose Approved perlite ftZ AA SBS.-TA or APP- concrete laid TA APP-TA Min. 22 ga., type B, (Optional) One or Min. 1/2-inch FM (Optional) BP- SBS-AA, S-20 Grade 33 steel or min. 2,500 psi structrual more layers, any combination, loose Approved high density See Note 2 1 per 4 ft2 BP -AA' SBS- AA AA, SBS-AA, SBS_-TA or APP- SBS-TA or -37.5* I concrete I laid —1 wood fiberboard 1 1 1 1 TA I APP-TA Exterior Research and Design, LLC. d/b/a Trinity[ERD Evaluation Report 3520.03.04-RS for FL2533-RS Certificate of Authorization #9503 Revision 5: 04/26/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 16 of 40 IF", n",__ \\JTRINITYII�RD TABLE 2B: STEEL OR CONCRETE DECKS — NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System Deck Base Insulation Top Insulation Layer Roof Cover No. (See Note 1) Layer(s) MDP (psf) Type Fasteners I Attach Base Ply Cap Min. 22 ga., type B, (Optional) One or Min. 1/4-inch SECUROCK (Optional) BP- SBS-AA, S-21 Grade 33 steel or min. more layers, any Gypsum -Fiber Roof See Note 2 1 per 4 ft,2 BP -AA, SBS- AA, SBS-AA, SBS-TA or -37.5* 2,500 psi structrual combination, loose Board AA -SBS-TA or APP- APP-TA concrete laid TA Min. 22 ga., type B, (Optional) One or (Optional) BP - S-22 Grade 33 steel or min. more layers, any Min. 2-Inch ACFoam II, See Note 2 1 per 1.6 ft2 BP-AA2 AA, SBS-AA, SBS-AA, SBS-TA or -37.5* 2,500 psi structrual combination, loose FlintBoard or ENRGY 3 SBS-TA or APP- concrete laid TA APP-TA Min. 22 ga., type B, (Optional) One or Min. 1/4-Inch SECUROCK BP -AA SBS- (Optional) BP- SBS-AA, S-23 Grade 33 steel or min. 2,500 psi structrual more layers, any combination, loose Gypsum -Fiber Roof See Note 2 1 per 4 ft2 AA, S9S-TA or AA, SBS-AA, SBS-TA or APP- SBS-TA or -45.0* concrete laid Board APP-TA TA APP-TA Min. 22 ga., type B, (Optional) One or Min. 1/2-inch FM (Optional) BP- S-24 Grade 33 steel or min. more layers, any Approved Wood See Note 2 1 per 2 ft2 BP -AA or SBS- AA, SBS-AA, SBS-AA, SBS-TA or -45.0* 2,500 psi structrual combination, loose Fiberboard, min. 3/4-inch AA SBS-TA or APP- concrete laid FM Approved perlite TA APP-TA Min. 22 ga., type B, (Optional) One or BP -AA, SBS- (Optional) BP- SBS-AA, S-25 Grade 33 steel or min. more layers, any Min. 1/4-inch DensDeck See Note 2 1 per 2 ft2 AA, SBS-TA or AA, SBS-AA, SBS-TA or -45.0* 2,500 psi structrual combination, loose or DensDeck Prime APP-TA SBS-TA or APP- APP-TA concrete laid TA Min. 22 ga., type B, (Optional) One or Min. 1-Inch FescoBoard (Optional) BP- S-26 Grade 33 steel or min. more layers, any (homogeneous) or min. See Note 2 1 per 1.6 ft2 BP-AA2 AA, SBS-AA, SBS-AA, SBS-TA or -45.0* 2,500 psi structrual combination, loose 1.5-inch FescoBoard SBS-TA or APP- concrete laid (laminated) TA APP-TA Min. 22 ga., type B, (Optional) One or Min. 1/2-inch Structodek, (Optional) BP - S-27 Grade 33 steel or min. more layers, any Structodek HD, GP HD See Note 2 1 per 2 ft2 BP-AA2 AA SBS-AA, SBS-AA, SBS-TA or -45.0* 2,500 psi structrual combination, loose Roof Fiberboard or SBS-TA or APP- concrete laid Temple HDI or HD6 TA APP-TA Min. 22 ga., type 5, (Optional) One or Min. 1.5-inch ACFoam S-28 Grade 33 steel or min. more layers, any II, FlintBoard,.ENRGY 3, See Note 2 1 per IAS BP-AA3 (Optional) BP -AA SBS-AA -52.5 2,500 psi structrual combination, loose MultiMax FA3 or H- itz or SBS-AA concrete laid Shield Min. 22 ga., type B, (Optional) One or Min. 1.5-inch ACFoam S-29 Grade 33 steel or min. more layers, any 11, FlintBoard, ENRGY 3, See Note 2 1 per 1.45 BP-AA3 BP -AA or SBS-AA SBS-TA 2,500 psi structrual combination, loose MultlMax FA3 or H- ft2 -52.5 concrete laid Shield Min. 22 ga., type B, Grade 33 steel or min. Min. 2-Inch ACFoam 11, Min. 1/2-Inch SECUROCK I per 1.78 BP -AA, SBS- (Optional) BP - AA, SBS-AA, SBS-AA, S-30 2,500 psi structrual FlintBoard, H- Gypsum -Fiber Roof See Note 2 ftZ AA, SBS-TA or SBS-TA or APP- SBS-TA or -60.0 concrete Shield or ENRGY 3, Board APP-TA TA APP-TA loose laid. Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report 3520.03.04-115 for FL2533-RS Certificate of Authorization #9SO3 Revision 5: 04/26/2011 Prepared by: Robert Nleminen, PE-59166 Appendix 1, Page 17 of 40 I rTRINITYIERD ,I TABLE 2C: STEEL OR CONCRETE DECKS — NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER SYSTEM TYPE D: PRELIMINARILY ATTACHED INSULATION, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Deck insulation Layer(s) Base or Anchor Sheet Roof Cover MDP No. I (See Note 1) Type Attach Base Fasteners Attach Ply Cap (Psf) SELF -ADHERING SYSTEMS: Min. 22 ga., type B, Grade 33 steel Min. 1.5-inch, One or Prelim. Flintlastic SA 9-inch o.c. at 4-inch lap and 18- S-1 or min. 2,500 psi more layers, any Attached NaIlBase See Note 2 Inch o.c. In two, equally spaced, SBS-SA SBS-SA -45.0* structrual concrete combination staggered center rows Min. 22 ga., type B, Grade 33 steel Min. 1.5-Inch, One or Prelim. I'lintlastIc SA 12-Inch o.c. at 4-Inch lap and S-2 at max. 6 ft spans more layers, any Attached NaIlBase See Note 2 12-inch o.c. In two, equally SBS-SA SBS-SA -60.0 or min. 2,500 psi combination spaced, staggered center rows I structrual concrete Min. 22 ga., type B, Grade 33 steel Min. 1.5-inch, One or Prelim. Flintlastic SA S-3 at max. 6 ft spans more layers, any Attached NaIlBase See Note 2 8-Inch o.c. at 4-Inch lap SBS-SA SBS-SA -82.5 or min. 2,500 psi combination structrual concrete CONVENTIONAL SYSTEMS: Min. 22 ga., type Glasbase; All B, Grade 33 steel Min. 1.5-Inch, One or Prelim Weather/Emplre 12-Inch o.c. at 4-Inch lap and BP -AA, SBS- SBS-AA S-4 or min. 2,500 psi more layers, any Attached Base; Flexiglas See Note 2 36-inch o.c. In two, equally AA, SBS-TA or SBS-TA or -30.0* structrual concrete combination Base; Flintlastic spaced, staggered center rows APP-TA APP-TA Base 20; Yosemite Min. 22 ga., type B, Grade 33 steel Min. 1.5-Inch, One or Prelim. Glasbase; All Weather/EmpIre 12-Inch o.c. at 4-Inch lap and BP -AA, SBS- SBS-AA, S-5 or min. 2,500 psi more layers, any Attached Base; Flexiglas See Note 2 24-inch o.c. In two, equally AA, SSS-TA or SBS-TA or -45.0* structrual concrete combination Base; FlIntlastic spaced, staggered center rows APP-TA APP-TA Base 20; Yosemite Min. 22 ga., type B, Grade 33 steel Min. 1.5-inch, One or Prelim. Poly SMS Base; 12-Inch o.c. at 4-Inch lap and BP -AA, SBS- SBS-AA, S-6 or min. 2,500 psi more layers, any Attached Ultra Poly SMS See Note 2 36-Inch o.c. In two, equally AA, SBS-TA or SBS-TA or -45.0* structrual concrete combination Base spaced, staggered center rows APP-TA APP-TA I Min. 22 ga., type B, Grade 33 steel Min. 1.5-inch, One or Prelim. Poly SMS Base; 18-Inch o.c. at 4-Inch lap and BP -AA, SBS- SBS-AA, S-7 or min. 2,500 psi more layers, any Attached Ultra Poly SMS See Note 2 18-Inch o.c. In one staggered AA, SBS-TA or SBS-TA or I 45.0* structrual concrete combination Base I center row APP-TA APP-TA Min. 22 ga., type B, Grade 33 steel Min. 1.5-Inch, One or Prelim. Poly SMS Base; Dekfast IF- 2-SB plates 12-Inch o c. within the min. 4- SBS-AA, SBS- SBS-AA or min. 2,500 psi more layers, any combination Attached Ultra Poly SMS Base with #14 Inch wide, heat -welded side lap TA or APP-TA S13S-TA.r APP-TA -45.0* structrual concrete Dekfast Exterior Research and Design, LLC. d/b/a TrInItyjEPD Evaluation Report 3520.03.04-R5 for FL2533-R5 Certificate of Authorization #9503 Revision 5: 04126/2011 Prepared by: Robert Nleminen, PE-59166 Appendix 1, Page IS of 40 1� R TY ERD INI TABLE 20 STEEL OR CONCRETE DECKS — NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER SYSTEM TYPE D: PRELIMINARILY ATTACHED. INSULATION, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Deck Insulation Layer(s) Base or Anchor Sheet Roof Cover MDP No. (See Note 1) Type Attach Base Fasteners Attach Ply Cap (Psf) Glasbase; Flexiglas Min. 22 ga., type B, Grade 33 steel Min. 1.5-Inch, One or Prelim. Base; FlIntlastic Base 20; All 12-inch o.c. at 3-Inch lap and BP -AA, SBS- SBS-AA, S-9 or min. 2,500 psi more layers, any Attached Weather/ Empire See Note 2 12-inch o.c. In two, equally AA, SBS-TA or SBS-TA or -52.5 structrual concrete combination Base; Poly SMS spaced, staggered center rows APP-TA APP-TA Base; Yosemite TruFast 2.4 Min. 22 ga., type Min. 1.5-inch, One or in. Barbed (Optional) S-10 B, Grade 80 steel more layers, any Prelim. Ultra Poly SMS Seam 12-Inch o.c. within the min. 4- SBS-TA or SBS-TA or -60.0 or min. 2,500 psi combination Attached Base Plates with Inch wide, heat -welded side lap APP-TA APP-TA structrual concrete TruFast EHD OMG Flat Min. 22 ga., type B, Grade 33 steel Min. 1.5-Inch, One or Prelim. Bottom . Plates with 6-inch o.c. at 4-Inch lap and 6- BP -AA, SBS- SBS-AA, 5-11 or min. 2,500 psi more layers, any Attached Glasbase; Yosemite OMG #14 Inch o.c. In two, equally spaced, AA, SBS-TA or SBS-TA or -67.5 structrual concrete combination HD staggered center rows APP-TA APP-TA (Accutrac) Min. 22 ga., type B, Grade 33 steel Min. 1.5-Inch, One or Prelim Flexiglas Base; 6-Inch o.c. at 4-Inch lap and 6- BP -AA, SBS- SBS-AA, S-12 or min. 2,500 psi more layers, any Attached FlIntlastic Base 20; See Note 2 Inch o.c. In two, equally spaced, AA, SBS-TA or SBS-TA or -67.5 structrual concrete combination Yosemite staggered center rows APP-TA APP-TA Min. 22 ga., type B, Grade 80 steel Min. 1.5-Inch, One or Prelim. Poly SMS Base; 12-inch o.c. at 4-Inch lap and SBS-TA or SBS-TA or S-13 or min 2,500 psi more layers, any Attached Ultra Poly SMS See Note 2 12-inch o.c. In two, equally APP-TA APP-TA -112.5 structr�al concrete combination Base spaced, staggered center rows Min. 22 ga., type B, Grade 80 steel Min. 1.5-Inch, One or Prelim Poly SMS Base; 12-Inch o.c. at 4-inch lap and SBS-AA or S-14 or min. 2,500 psi more layers, any Atta&d Ultra Poly SMS See Note 2 12-Inch o.c. In two, equally SBS-AA SBS-TA -120.0 structrual concrete combination Base spaced, staggered center rows COLD -APPLIED SYSTEMS: Min. 22 ga., type Glasbase; All B, Grade 33 steel Min. 1.5-Inch, One or Prelim. Weather/Empire 6-inch o.c. at 4-Inch lap and 12- S-15 or min. 2,500 psi more layers, any Attached Base; Flexiglas See Note 2 Inch o.c. In two, equally spaced, SBS-CA1 SBS-CA1 -45.0* structrual concrete combination Base; FlIntlastic staggered center rows Base 20 Exterior Research and Design, LLC. d/b/a TrIn1tyjERD Evaluation Report 3520.03.04-RS for FI-2533-115 Certificate of Authorization #9503 Revision 5: 04/26/2011 Prepared by: Robert Nleminen, PE-59166 Appendix 1, Page 19 of 40 TY;ERD -J TRINI TABLE 3A: CONCRETE DECKS - NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER SYS. Dec'k) Base Insulation Layer 7 Top Insulation Layer I Roof Cover No. (Se4 I Primer MDP (psf) Note Type Attach Type Attach Base Ply Cap SELF -ADHERING SYSTEMS: C-1. Concrete ASTM D41 Min. 1.5-inch FlintBoard ISO, ACFoam II, ENRGY 3 or Multi- HA Min. 1/4-inch DensDeck HA SBS-SA (Optional) SBS- SBS-SA -105.0 Max FA3 DuraGuard SA C-2. Concrete ASTM D41 Min. 1.5-inch ACFoam II, HA Min. 1/4-inch SECUROCK Gypsum- HA SBS_SA (Optional) SBS- SBS-SA -172.5 FlintBoard, ENRGY 3 or H-Shleld Fiber Roof Board SA C-3. Concrete ASTM D41 Min. 1.5-inch ACFoarn II, FlintBoard, ENRGY 3 or Multi -Max HA Min. 1/4-inch DensDeck primed HA SBS-SA (Optional) SBS- SBS-SA -192.5 FA3 with FlintPrime SA SA C-4. Concrete None Min. 1.5-inch ACFoarn II, FlintBoard, ENRGY 3 or Multi -Max A-PD Mjn. 1/4-inch DensDeck primed A-PD SBS-SA (Optional) SBS- SBS-SA -105.0 FA3 w th FlintPrime SA SA C-5. Concrete None Min. 1.5-inch ACFoam II, A-PD Min. 1/4-inch SECUROCK Gypsum- A-PD SBS-SA (Optional) SBS- SBS-SA- -172.5 FlintBoard, ENRGY 3 or H-Shield Fiber Roof Board SA C-6. Concrete None Min. 1.5-inch ACFoarn 11, FlintBoard, ENRGY 3 or Multi -Max A-PD Min. 1/4-inch DensDeck primed A-PD SBS-SA (Optional) SBS- SBS-SA -192.5 FA3 6-inch o.c. with FlintPrime SA 6-Inch o.c. SA C-7. Concrete (Optional) Min. 1.5-inch Multi -Max FA D-IS or D- Min. 1/4-inch DensDeck primed D-IS or D- SBS-SA (Optional) SBS- SBS-SA -67.5 ASTM D41 SG with FlintPrime SA SG SA C-8. Concrete (Optional) Min. 1.5-inch FlintBoard ISO, ACFoam 11, ENRGY 3 or Muld- D-IS or D- Min. 1/4-inch DensDeck D-IS or D- SBS-SA (Optional) SBS- SBS-SA -105.0 ASTM D41 Max FA3 SG DuraGuard SG SA C-9. Concrete (Optional) Min. 1.5-inch ENRGY 3 D-IS or D- Min. 1/4-inch DensDeck primed D-IS or D- SBS-SA (Optional) SBS- SBS-SA -112.5 ASTM D41 SG with FlintPrime SA SG SA C-10. Concrete (Optional) Min. 1.5-inch ACFoarn II or D-IS or D- Min. 1/4-inch DensDeck primed D-IS or D- SBS-SA (Optional) SBS- ASTM D41 FlintBoard SG with FlintPrime SA SG SA SBS-SA -120.0 C-1 1. Concrete None Min. 1.5-inch ACFoam II 4-Shleld D-IS Min 1/4-inch SECUROCK Gypsum- D-IS SBS-SA (Optional) SBS- SBS-SA -172.5 FllntBoard, ENRGY 3 or Fiber Roof Board SA C-12. Concrete None Min. 1.5-inch ACFoarn II, FlintBoard, ENRG Y 3 or Multl-Max M-PFIA Min 1/4-inch DensDeck Primed M-PFIA SBS-SA (Optional) SBS- SBS-SA -135.0 I FA wlt� FllntPr1me SA SA C-13. Concrete (Optional) Min. 1.5-inch FlintBoard ISO ACFoam II, ENRGY 3 or Mul ii- M-OSFA or Min. 1/4-inch DensDeck M-OSFA or SBS-SA (Optional) SBS- SBS-SA -105.0 ASTM D41 Max FA3 M-PG1 DuraGuard M-PG1 SA C-14. Concrete None Min. 1.5-inch ACFoam 11, M-OSFA or Min. 1/4-inch SECUROCK Gypsum- M_OSFA or SBS-SA (Optional) SBS- SBS-SA -172.5 FlintBoard, ENRGY 3 or H-Shield M-PG1 Fiber Roof Board M-PG1 SA C-15. Concrete None Min. 1.5-inch ACFoam II Flintl3oard, ENRGY 3 or �ulti-Max M-OSFA or Min. 1/4-inch DensDeck primed M_OSFA or SBS-SA (Optional) SBS_ I SBS-SA -192.5 I I I FA M-PG1 with FlintPrime SA I M-PG1 SA Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report 3520.03.04-R5 for FL2533-RS Certificate of Authorization #9503 Revision 5: 04/26/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 20 of 40 \,ITRINITYIERD TABLE 3A: CONCRETE DECKS - NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Deck Base Insulation Layer Top Insulation Layer Roof Cover Sys. No. (See Primer MOP (psf) Note 1) Type Attach Type Attach Base Ply Cap (Optional) Min. 1.5-inch FlintBoard ISO, Min. 1/4-inch DensDeck (Optional) SBS- C-16. Concrete ASTM D41 ACFoam II, ENRGY 3 or Multi OB500 DuraGuard OBSOO SBS-SA SA SBS-SA -105.0 Max FA3 C-17. Concrete ASTM D41 Min. 13-Inch ACFoam 11, OB500 Min. 1/4-Inch DensDeck primed OB500 SBS-SA (Optional) SBS_ SBS-SA -120.0 FlintBoard ISO or ENRGY 3 with FlintPrime SA SA C-18. Concrete None Min. 1.5-inch ACFoam 11, OB500 Min. 1/4-Inch DensDeck primed OB500 SBS-SA (Optional) SBS- SBS-SA _IS0.0 FlintBoard ISO or ENRGY 3 with FlIntPrIme SA SA C-19. Concrete None Min. 1.5-Inch ACFoam II, OB500 Min. 1/4-Inch SECUROCK Gypsum- OB500 SBS-SA (Optional) SBS- SBS-SA -172.5 FlIntBoard, ENRGY 3 or H-ShIeld Fiber Roof Board SA Min. 1.0-Inch ISO 95+ GL, H- Shield, H-Shield CG, ENRGY 3 or C-20. Concrete None JM ISO 3 min. 1.3-Inch ACFoam CR-20 Min. 1/4-inch DensDeck CR-20 SBS-SA (Optional) SBS- SBS-SA -105.0 III, Min. 1.5-Inch Multi -Max FA3 DuraGuard SA or Ultra -Max or min. 2.0-Inch ACFoam IV Min. 1.0-inch ISO 95+ GL, H- Shield, H-Shleld CG, ENRGY 3 or C-21. Concrete None JM ISO 3 min. 1.3-inch ACFoam CR-20 Min. 1/4-inch SECUROCK Gypsum- CR-20 SBS-SA (Optional) SBS- SBS-SA -172.5 III, Min. 1.5-inch Multi -Max FA3 Fiber Roof Board SA or Ultra -Max or min. 2.0-inch ACFoam IV Min. 1.0-Inch 150 95+ GL, H- Shield, H-Shield CG, ENRGY 3 or C-22. Concrete None JM ISO 3 min. 1.3-Inch ACFoam CR-20 M,1n. 1/4-inch DensDeck primed CR-20 SBS-SA (Optional) SBS- SBS-SA -192.5 III, Min. 1.5-Inch Multi -Max FA3 w th FlintPrIme SA SA or Ultra -Max or min. 2.0-Inch ACFoam IV CONVENTIONAL SYSTEMS: C-23. Concrete ASTM D41 Min. 1.5-inch thick ACFoam II or HA Min. 1/4-Inch DensDeck, DensDeck Prime or DensDeck HA SBS-TA (Optional) SBS- SBS-TA -180.0 FlintBoard ISO. DuraGuard TA BP -AA, (Optional) BP- C-24. Concrete ASTM D41 M:nj 1.5 Inch thick ACFoam 11 or HA Min. 1/4-Inch SECUROCK Gypsum- HA SBS-AA, AA, SBS-AA, SBS-AA, SBS-TA or -180.0 Fl n Board ISO. Fiber Roof Board SBS-TA or SBS-TA or APP- APP-TA TA APP-TA Min. 2-Inch ACFoam II, Min. 1/4-inch SECUROCK Gypsum- BP -AA or (Optional) BP- AA, SBS-AA SBS-AA, C-25. Concrete ASTM D41 FlintBoard ISO, ENRGY 3 or H- HA Fiber Roof Board HA SBS-AA SBS-TA or XPP_ SBS-TA or -225.0 Shield TA APP-TA Min. 1.5-Inch ACFoam II, Min. 1/2-inch Structodek High BP -AA or (Optional) BP- AA, SB S-AA, SBS-AA, C-26. Concrete ASTM D41 FlintBoard ISO, ENRGY 3 or H- HA Density Fiberboard HA SBS-AA SBS-TA or APP- SBS-TA or I I I Shield I I I I I TA APP-TA Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report 3520.03.04-115 for FL2533-RS Certificate of Authorization #9503 Revision 5: 04/26/2011 Prepared by: Robert Niemlnen, PE-59166 Appendix 1, Page 21 of 40 TRINITYIERD 11 TABLE 3A: CONCRETE DECKS - NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Sys. Deck Base Insulation Lay r Top Insulation Layer Roof Cover No. (See Note 1) Primer MOP (psf) Type Attach Type Attach Base Ply - Cap C-27. Concrete ASTM D41 Min. 2-Inch ACFoam 11, FlintBoard ISO, ENRGY 3 or H- HA Min. 1/4-Inch SECUROCK Gypsum- HA SBS-TA or (Optional) SBS- SBS-TA or Shield Fiber Roof Board APP-TA TA or APP-TA APP-TA -232.5 Min. 1.5-Inch ACFoam II, (Optional) 1313- SBS-AA, C-28. Concrete ASTM D41 FlIntBoard ISO, ENRGY 3 or H- HA Min. 1/4-inch DensDeck HA BP -AA or AA, SBS-AA, SBS-TA or -240.0 Shield SBS-AA SBS-TA or APP- APP-TA TA (Optional) BP- C-29. Concrete ASTM D41 Min. 1.5-Inch ACFoam 11 or HA Min. 1/4-Inch FescoBoard HA BP -AA or AA, SB S-AA, SBS-AA, FlintBoard ISO (homogeneous) SBS-AA SBS-TA or APP- SBS-TA or -412.0 TA APP-TA C-30. Concrete ASTM D41 1:,n 1.5-Inch ACFoam 11 or HA Min. 1/2-inch DuraBoard HA BP -AA or (Optional) 1313- AA, SBS-AA SBS-AA, Fl 'i Board ISO (homogeneous) SBS-AA SBS-TA or XPP- SBS-TA or -430.0 TA APP-TA Min. 1.5-Inch ACFoam II, Min. 1/2-Inch Structodek High (Optional) BP- SBS-AA, C-31. Concrete None FlintBoard ISO, ENRGY 3 or H- A-PD Density Fiberboard or Min. 1/4- A-PD BP -AA or AA, SBS-AA �Pp- SBS-TA or -105.0 Shield Inch DensDeck SBS-AA SBS-TA or APP-TA TA Min. 1.5-inch ACFoam II, N-PD Min. 1/2-Inch Structodek High A-PD (Optional) 1313- SBS-AA, C-32. Concrete None FlIntBoard ISO, ENRGY 3 or H- Density Fiberboard or Min. 1/4- BP -AA or AA, SBS-AA, SBS-TA or -217.5 Shield 6-Inch o.c. inch DensDeck 6-Inch o.c. SBS-AA SBS-TA or APP APP-TA TA C-33. Concrete None Min. 2-Inch ACFoam 11, FlintBoard ISO, ENRGY 3 or H- A-PD Min. 1/4-inch SECUROCK Gypsum- A-PD BP -AA or SBS-AA, (Optional) BP- AA, SBS-AA, SBS-AA, Shield Fiber Roof Board SBS-TA or SBS-TA or APP- SBS-TA or -217.5 APP-TA TA APP-TA C-34. Concrete None Min. 1.5-inch thick ACFoam 11 or FlintBoard ISO. D-IS Min. 1/4-Inch DensDeck D-IS SBS-TA (Optional) SBS- SBS-TA -112.5 TA C-35. Concrete None Min. 2-Inch ACFoam II, FlintBoard ISO, ENRGY 3 or H- D-IS Min' 1/4-inch SECUROCK Gypsum- D-IS BP -AA or (Optional) BP- AA, SBS-AA, SBS-AA, Shield Fiber Roof Board SBS-AA SBS-TA or APP- SBS-TA or -225.0 TA APP-TA Min. 2-Inch ACFoam II, C-36. Concrete None FlintBoard ISO, ENRGY 3 or H- D-IS Min. 1/4-Inch SECUROCK Gypsum- D-IS SBS-TA or (Optional) SBS- SBS-TA or Shield Fiber Roof Board APP-TA TA or APP-TA APP-TA -232. C-37. Concrete None Min. 1.5-Inch thick ACFoam 11 or FlintBoard ISO. M-PFIA Min. 1/4-inch DensDeck M-PFIA SBS-TA (Optional) SBS- SBS-TA -135.0 TA C-38. Concrete None Min. 1.5-Inch thick ACFoam 11 or FlintBoard ISO. M-PFIA Min. 1/4-Inch SECUROCK Gypsum- M-PFIA SBS-TA (Optional) SBS- SBS-TA -180.0 Fiber Roof Board TA C-39. Concrete None Min. 1.5-Inch ACFoam 11, Flintl3oard ISO, ENRGY 3 or H- M-OSFA Min. 1/2-Inch Structodek High M-OSFA BP -AA or (Optional) BP- AA, SB S-AA SBS-AA, Shield Density Fiberboard SBS-AA SBS-TA or �pp- SBS-TA or -127.5 TA APP-TA Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report 3520.03.04-115 for FL2533-R5 Certificate of Authorization #9503 Revision 5: 04/26/2011 Prepared by: Robert Nlemlnen, PE-59166 Appendix 1, Page 22 of 40 j . TRINITY ERD TABLE 3A: CONCRETE DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Deck Base Insulation Layer Top Insulation Layer Roof Cover Sys. No. (See Primer MDP (psf) Note 1) Type Attach Type Attach Base Ply Cap C-40. Concrete None Min. 1.5-inch ACFoarn II, FlintBoard ISO, ENRGY 3 or H- M-PG1 Min. 1/2-inch Structodek High M_PG1 BP -AA or (Optional) BP- AA, SBS-AA SBS-AA, SBS-TA or -180.0 Shield Density Fiberboard SBS-AA SBS-TA or XPP- APP-TA TA Min. 1.5-inch ACFoarn II, (Optional) BP- SBS-AA, C-41. Concrete None FlintBoard ISO, ENRGY 3 or H- M-OSFA Min. 1/4-inch DensDeck M-OSFA BP -AA or AA, SBS-AA SBS-TA or -232.5 Shield SBS-AA SBS-TA or XPP- APP-TA TA Min. 1.5-inch ACFoarn II, (Optional) BP- SBS-AA, C-42. Concrete None FlintBoard ISO, ENRGY 3 or H- M-PG1 Min. 1/4-inch DensDeck M-PG1 BP -AA or AA, SBS-AA XPP- SBS-TA or -240.0 Shield SBS-AA SBS-TA or APP-TA TA C-43. Concrete None M:n. 2-inch ACFoarn II, F1 ntBoard ISO, ENRGY 3 or H- I S M-0 FA or Min. 1/4-Inch SECUROCK Gypsum- M-OSFA or BP -AA or (Optional) BP- AA, SBS-AA, SBS-AA, SBS-TA or -225.0 Shield M-PG1 Fiber Roof Board M-PG1 SBS-AA SBS-TA or APP APP-TA I TA C-44. Concrete None Min. 2-inch ACFoam II, FlintBoard ISO, ENRGY 3 or H- M-OSFA or Min. 1/4-inch SECUROCK Gypsum- M-OSFA or SBS-TA or (Optional) SBS- SBS-TA or -232.5 Shield M-PG1 Fiber Roof Board M-PG1 APP-TA TA or APP-TA APP-TA C-4S. Concrete None Min. 1.S-Inch ACFoarn II, FlintBoard ISO, ENRGY 3 or H- OB500 Min. I/z-lnch Structodek High OB500 BP -AA or (Optional) BP- AA, SBS-AA SBS-AA, SBS-TA or -120.0 Shield Density Fiberboard SBS-AA SBS-TA or XPP- APP-TA 1 TA C-46. Concrete None Min. 1.5-inch thick ACFoarn II or OB500 Min. 1/4-inch DensDeck or OB500 BP -AA, SBS-AA, (Optional) BP- AA, SBS-AA, SBS-AA, SBS-TA or -150.0 FlintBoard ISO. DensDeck Prime SBS-TA or SBS-TA or APP- APP-TA TA APP-TA C-47. Concrete None Min. 2-inch ACFoam 11, FlintBoard ISO, ENRGY 3 or H- OB500 Min 1/4-inch SECUROCK Gypsum- OB500 BP -AA or (Optional) BP- AA, SBS-AA, SBS-AA, SBS-TA or -225.0 Shield Fiber Roof Board SBS-AA SBS-TA or APP- APP-TA TA C-48. Concrete None Min. 2-inch ACFoann 11, FlintBoard ISO, ENRGY 3 or H- OB500 Min. 1/4-inch SECUROCK Gypsum- OB500 SBS-TA or (Optional) SBS- SBS-TA or -232.5 Shield Fiber Roof Board APP-TA TA or APP-TA APP-TA Min. 1.0-inch ISd'95+ GL, H- Shield, H-Shleld CG, ENRGY 3 or Min. I/z-lnch Structodek High (Optional) BP- C-49. Concrete None JM ISO 3 min. 1.3-inch ACFoarn CR-20 Density Fiberboard or DuraBoard CR-20 BP -AA or AA, SBS-AA, SBS-AA, SBS-TA or -180.0 III, Min. 1.5-inch Multi -Max FA3 (homogeneous) or min. 1.5-inch SBS-AA SBS-TA or APP- or Ultra -Max or min. 2.0-inch FescoBoard (laminated) TA APP-TA ACFoam IV Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report 3520.03.04-RS for FL2533-R5 Certificate of Authorization #9503 Revision 5: 04/26/2011 Prepared by: Robert Nlerninen, PE-59166 Appendix 1, Page 23 of 40 t 0 f�RINITY 1 ERD TABLE 3A: CONCRETE DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Deck Base Insulation Layer Top Insulation Layer Roof Cover Sys. No. (See Primer MOP (psf) Note 1) Type Attach Type Attach Base Ply Cap Min. 1.0-inch ISO 95+ GL, H- Shield, H-Shleld CG, ENRGY 3 or (Optional) BP- SBS-AA, C-50. Concrete None JM ISO 3 min. 1.3-inch ACFoam CR-20 Min. 1/4-inch SECUROCK Gypsum- CR-20 BP -AA or AA, SBS-AA, SBS-TA or -225.0 III, Min. 1.5-inch Multi -Max FA3 Fiber Roof Board SBS-AA SBS-TA or APP- APP-TA or Ultra -Max or min. 2.0-Inch TA ACFoam IV Min. 1.0-inch ISO 95+ GL, H- Shield, H-Shleld CG, ENRGY 3 or C-51. Concrete None JM ISO 3 min. 1.3-inch ACFoam CR-20 Min. 1/4-inch SECUROCK Gypsum- CR-20 SBS-TA or (Optional) SBS- SBS-TA or -232.5 III, Min. 1.5-inch Multl-Max FA3 Fiber Roof Board APP-TA TA or APP-TA APP-TA or Ultra -Max or min. 2.0-inch ACFoarn IV Min. 1.0-inch ISO 95+ GL, H- Shield, H-Shleld CG, ENRGY 3 or (Optional) BP- C-52. Concrete None IM ISO 3 min. 1.3-inch ACFoarn CR-20 Min. 1/4-inch DensDeck CR-20 BP -AA or AA, SBS-AA ' SBS-AA, SBS-TA or -240.0 III, Min. 1.5-inch Multi -Max FA3 SBS-AA SBS-TA or APP- APP-TA or Ultra -Max or min. 2.0-Inch TA ACFoam IV I TABLE 3B: CONCRETE DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE F: NON -INSULATED, BONDED ROOF COVER System No. Deck (See Note 1) I Primer I Roof Cover T MOP (pSf) se Ply I Ba Cap SELF -ADHERING SYSTEMS: C-53. Concrete FlintPrlrne SA T_SBS-SA T—(Optional) SBS-SA SBS-SA -555.0 C-54. concrete ASTM D41 SBS-SA (Optional) SBS-SA SBS-SA -630.0 HYBRID SYSTEMS: C-55. Concrete I ASTM D41 SBS-�A-H (Optional) BP -AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -240.0 CONVENTIONAL SYSTEMS: C-56. Concrete ASTM D41 BP -AA or SBS-AA (Optional) BP -AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -240.0 C-57. Concrete ASTM D41 SBS-TA (Optional) SBS-TA SBS-TA -542.5 Exterior Research and Design, LLC. d/b/a TrinityjERD Evaluation Report 3520.03.04-R5 for FL2533-R5 Certificate of Authorization #9503 Revision 5: 04/26/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 24 of 40 r-, N. TRINITY ERD TABLE 4A: LIGHTWEIGHT CONCRETE DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Deck Base Insulation Layer C . overboard Roof Cover System (See Note 1) MOP No. Struct'. LWC Type Attach Type Attach Base Ply Cap (PSf) Deck SELF -ADHERING SYSTEMS: Min. 200 psi, min. 2-Inch Min. 1.5-Inch FlintBoard ISO, A-PD, 6- Min. 1/4-Inch DensDeck A-PD, 6- (Optional) LWC-1 Concrete thick Elastizell ACFoam II, ENRGY 3 or Multi -Max inch o.c. DuraGuard Inch o.c. SBS-SA SBS-SA SBS-SA -105.0 FA3 LWC-2 Concrete Min. 200 psi, min. 2-inch Min. 1.5-Inch ACFoam II, , A-PD, 6- Min. 1/4-Inch SECUROCK Gypsum -Fiber Roof A-PD, 6- SBS-SA (Optional) SBS-SA -172.5 thick Elastizell FlintBoard, ENRGY 3 or H-Shield Inch o.c. Board Inch o.c. SBS-SA Min. 200 psi, min. 2-inch Min. 1.5-inch ACFoam II, A-1313, 6- Min. 1/4-Inch DensDeck A-PD, 6- (Optional) LWC-3 Concrete thick Elastizell FlintBoard, ENRGY 3 or Multi -Max inch o.c. primed with FlintPrime Inch o.c. SBS-SA SBS-SA SBS-SA -187.5 FA3 SA LWC-4 Concrete Min. 200 psi, min. 2-Inch Min. 1.5-Inch FlintBoard ISO, ACFoam II, ENRGY 3 or Multi -Max OB500 Min. 1/4-Inch DensDeck OB500 SBS-SA (Optional) SBS-SA -105.0 thick Elastizell FA3 DuraGuard SBS-SA LWC_S Concrete Min. 200 psi, min. 2-inch Min. 1.5-Inch ACFoam II, Flint5oard OB500 Min. 1/4-inch DensDeck primed with FlintPrime OB500 SBS_SA (Optional) SBS-SA -150.0 thick Elastizell ISO or ENRGY 3 SA SBS-SA LWC-6 Concrete Min. 200 psi, min. 2-Inch Min. 1.5-Inch ACFoam II, OBSOO Min. 1/4-Inch SECUROCK Gypsum -Fiber Roof OB500 SBS-SA (Optional) SBS-SA -172.5 thick Elastizell FlintBoard, ENRGY 3 or H-Shleld Board SB5-SA Min. 1.0-inch ISO 95+ GL, H-Shleld, Min. 200 psi, min. 2-Inch H-Shleld CG, ENRGY 3 or JM ISO 3 Min. 1/4-Inch DensDeck (Optional) LWC-7 Concrete thick Celcore, Elastizell or min. 1.3-Inch ACFoam III, Min. 1.5- CR-20 DuraGuard CR-20 SBS-SA SBS-SA SBS-SA -105.0 Celcore Inch Multi -Max FA3 or Ultra -Max or min. 2.0-inch ACFoam IV Min. 1.0-Inch ISO 95+ GL, H-Shield, Min. 200 psi, min. 2-Inch H-Shleld CG, ENRGY 3 or JM ISO 3 Min. 1/4-inch SECUROCK (Optional) LWC-8 Concrete thick Celcore, Elastizell or min. 1.3-Inch ACFoam 111, Min. 1.5- CR-20 Gypsum -Fiber Roof CR-20 SBS-SA SBS-SA SBS-SA -172.5 Celcore Inch Multi -Max FA3 or Ultra -Max or Board min. 2.0-Inch ACFoam IV Min. 1.0-inch ISO 95+ GL, H-Shield, Min. 200 psi, min. 2-Inch H-Shield CG, ENRGY 3 or JM ISO 3 Min. 1/4-inch DensDeck (Optional) LWC-9 Concrete thick Celcore, Elastizell or min. 1.3-inch ACFoam 111, Min. 1.5- CR-20 primed with FlintPrime CR-20 SBS-SA SBS-SA SBS-SA -180.0 Celcore Inch Multi -Max FA3 or Ultra -Max or SA min. 2.0-inch ACFoam IV CONVENTIONAL SY EMS: A-PD Min. 1/2-Inch Structodek A-PD (Optional) BP - SBS-AA1 LWC-10 Concrete Min. 200 psi, min. 2-Inch Min. 1.5-Inch ACFoam 11, FlintBoard 6-inch High Density Fiberboard 6-Inch BP -AA or AA, SBS-AA SBS-TA or -187.5 thick Elastizell ISO, ENRGY 3 or H-Shleld or Min. 1/4-Inch SBS-AA SBS-TA or . D.C. DensDeck O.C. APP-TA APP-TA Exterior Research and Design, LLC. d/b/a TrInItyjERD Evaluation Report 3520.03.04-115 for FL2533-RS Certificate of Authorization #9503 Revision 5: 04/26/2011 Prepared by: Robert Nleminen, PE-59166 Appendix 1, Page 25 of 40 '\j TRINITY ERD TABLE 4A: LIGHTWEIGHT CONCRETE DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Deck System (See Note 1) Base Insulation Layer Coverboard Roof Cover MDP No. Struct, — (PSf) Deck LWC Type Attach Type Attach Base Ply Cap LWC-11 Concrete Min. 200 psi, min. 2-Inch Min. 1.5-Inch ACFoam II, FlIntboard A-PD, 6- Min. 1/4-Inch SECUROCK Gypsum -Fiber Roof A-PD, 6- BP -AA or SBS-AA, (Optional) BP- AA, SBS-AA, SBS-AA, thick Elastizell ISO, ENRGY 3 or H-Shleld Inch o.c. Board Inch o.c. SBS-TA or SBS-TA or SBS-TA or -217.5 APP-TA APP-TA APP-TA BP -AA, (Optional) BP- LWC-12 Concrete Min. 200 psi, min. 2-Inch Min. 1.5-Inch thick ACFoam II or OB500 Min. 1/4-Inch DensDeck OBSOO SBS-AA, AA, SBS-AA SBS-AA, thick Elastizell FlIntBoard ISO. or DensDeck Prime SBS-TA or SBS-TA or SBS-TA or -150.0 APP-TA APP-TA APP-TA LWC-13 Concrete Min. 200 p si, min. 2-Inch thick Elastizell Min. 1.5-inch thick ACFoarn 11 or FlintBoard ISO. OB500 Min. 1/4-Inch SECUROCK Gypsum -Fiber Roof OB500 SBS-TA (Optional) SBS-TA -180.0 Board SBS-TA LWC-14 Concrete Min. 200 psi, min. 2-Inch Min. 2-Inch ACFoarn II, FlIntBoard OBSOO Min. 1/4-Inch SECUROCK Gypsum -Fiber Roof OBSOO BP-AA1 SBS-AA, I (Optional) BP- AA, SBS-AA1 SBS-AA, thick Elastizell ISO, ENRGY 3 or H-Shield Board SBS-TA or SBS-TA or SBS-TA or -225.0 APP-TA APP-TA APP-TA Min. 1.0-Inch ISO 95+ GL, H-Shield, Min. 1/2-Inch Structodek Min. 200 psi, min. 2-Inch H-Shleld CG, ENRGY 3 or JM ISO 3 High Density Fiberboard (Optional) BP- SBS-AA, LWC-15 Concrete thick Celcore, Elastizell or min. 1.3-inch ACFoam III, Min. 1.5- CR-20 or DuraBoard (homogeneous) or min. CR-20 BP -AA or SBS-AA AA, SBS-AA, SBS-TA SBS-TA or -180.0 Celcore Inch Multi -Max FA3 or Ultra -Max or or APP-TA min. 2.0-Inch ACFoarn IV 1.5-Inch FescoBoard APP-TA I (laminated) Min. 1.0-Inch ISO 95+ GL, H-Shleld, Min. 200 psi, min. 2-Inch H-Shield CG, ENRGY 3 or 3M ISO 3 Min. 1/4-Inch SECUROCK BP -AA, (Optional) BP- SBS-AA, LWC-16 Concrete thick Celcore, Elastizell or min. 1.3-Inch ACFoam III, Min. 1.5- CR-20 Gypsum -Fiber Roof CR-20 SBS-AA, AA , SBS-AA ' SBS-TA or -180.0 Celcore Inch Multi -Max FA3 or Ultra -Max or Board or DensDeck or SBS-TA or SBS-TA or APP-TA min. 2.0-Inch ACFoam IV DensDeck Prime APP-TA APP-TA COLD APPLIED SYSTEMS: Min. 22 ga. steel at Min. 3SO psi, min 2-Inch LWC-17 max 5 ft spans or thick Range II Elastizell Ughtwelght Insulating Min. 1.5-inch H-Shield CG OB500, 6-inch (Optional) Additional layers of base OB500, 6-inch BP-CA3 or (Optional) BP - CA3 or SBS- SBS-CA3 -60.0 structural Concrete with Zell Fibers. D.C. Insulation D.C. SBS-CA3 CA3 concrete Min. 350 psi, min 2-inch Min. 22 ga. thick Range II Elastizell steel at Ughtwelght Insulating max 5 ft Concrete with Zell Fibers. OB500, (Optional) Additional OB500, BP-CA3 (Optional) BP- LWC-18 spans or When walkable, attach LWC Min. 1.5-Inch H-Shield CG 6-inch layers of base 6-Inch or SBS-CA3 CA3 or SBS- SBS-CA3 -67.5 structural with Flintfast #14 and D.C. Insulation D.C. CA3 concrete FlIntfast 3" Round Plates at 1 per 8 ft2 through to the structural deck. Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report 3520.03.04-115 for FL2533-RS Certificate of Authorization #9503 Revision 5: 04/26/2011 Prepared by: Robert Nierninen, PE-59166 Appendix 1, Page 26 of 40 T�1NITY11ERD TABLE 4C: LIGHTWEIGHT CONCRETE DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Deck (See Note 1) Base Sheet Roof Cover NO. Structural Deck Lightweight Concrete Type Fasteners Attach Ply cap MD ipsf) SELF -ADHERING SYSTEMS: Min. 22 ga. Min. 300 psi, min. 2-Inch thick Approved cellular 7-Inch o.c. at the 4-Inch lap and steel at max lightweight Insulating concrete. Note: To qualify the LINIC under this assembly, a 1. 8-Inch Twin Min. 1.8-inch 7-Inch o.c. In two, equally spaced, LWC-19 5 ft spans or Loc-Nail shall achieve an average withdrawal of Flintlastic SA NallBase ES Products staggered center rows SBS-SA SBS-SA -60.0 structural 69 lbf when tested per TAS 105 or ANSrISPRI Twin Loc-Nall Stress plates shall be primed with concrete FX-1 ASTM D41 primer or FlintPrime SA Min. 22 ga. Min. 300 psi, min. 2-Inch thick Approved cellular 9-fnch o.c. at the 4-Inch lap and steel at max lightweight Insulating concrete. Note: To q ualify the LIVIC under this assembly, a 1. 8-inch Twin Min. 1.8-Inch 9-Inch o.c. In two, equally spaced, LWC-20 5 ft spans or Loc-Nail shall achieve an average withdrawal of Flintlastic SA NallBase ES Products staggered center rows SBS-SA SBS-SA -60.0 structural 88 Jbf when tested per TAS 105 or ANSIISPRI Twin Loc-Nail Stress plates shall be primed with concrete FX-J ASTM D41 Primer or FlintPrime SA HYBRID SYSTEMS: Min. 26 ga. Glasbase; Flexiglas ES Products LWC-21 steel at max 5 ft spans or Min. 200 psi, min 2-Inch thick Range II Elastizell Base; Flintlastic Base 0 B t ase Ply Fas eners 71/2-inch o.c. at the 4-Inch lap and SBS-AA, Lightweight Insulating Concrete. 20; All Weather/ or Twin Loc- 71/2-Inch o.c. In two, equally SBS-SA-H SBS-TA or -30.0 structural Empire Base or Poly Nails (1.8 spaced, staggered center rows APP-TA concrete SMS Base Inch) Min. 22 ga. Glasbase; Flexiglas ES Products LWC-22 steel at max 5 ft spans or Min. 200 psi, min 2-Inch thick Range II Elastizell Base; FlIntlastic Base - as Ply F st ne 7-Inch o.c. at the 4-Inch lap and SBS-AA, Lightweight Insulating Concrete. 20; All Weather/ . orT 1 oc- 7-fnch o.c. In two, equally spaced, SBS-SA-H SBS-TA or -45.0 structural Empire Base or Poly Nails staggered center rows APP-TA concrete SMS Base Inch) Min. 22 ga. Min. 300 psi, min. 2-Inch thick Approved cellular steel at max lightweight Insulating concrete. Note: To qualify the LWIC under this assembly, a 1.8-Inch Twin Glasbase; Flexiglas Base; Flintlastic Base Min. 1.8-inch 9-Inch o.c. at the 4-Inch lap and SBS-AA, LWC-23 5 ft spans or structural Loc-Nall shall achieve an average withdrawal of 20; All Weather ES Products 9-inch o.c. In two, equally spaced, SBS-SA-H SBS-TA or -60.0 88 1bf when tested per TAS 105 or ANS11SPRI Empire Base Twin Loc-Nall staggered center rows APP-TA concrete FX-1 Min. 22 ga. Min. 350 psi, min. 3-Inch thick Approved cellular steel at max lightweight Insulating concrete. Note: To qualify the LWIC under this assembly, a 1.8-Inch Twin Flexiglas Base; ES Products 7-Inch o.c. at the 4-Inch lap and SBS-AA, LWC-24 5 ft spans or Lac-Naff shall achieve an average withdrawal of FlIntlastic Base 20 or FM-90 Base 10-Inch o.c. In two, equally SBS-SA-H SBS-TA or -67.5 structural 97 lbf when tested per TAS 105 or ANSIISPRI Poly SMS Base Ply Fasteners spaced, staggered center rows APP-TA concrete FX-1 Min. 22 ga. Min. 300 psi, min. 2-Inch thick Approved cellular steel at max lightweight Insulating concrete. Note: To qualify the LWIC under this assembly, a 1.8-inch Twin Poly SMS Base; Ultra Min. 1.8-Inch 9-Inch o.c. at the 4-Inch lap and SBS-AA, LWC-25 5 ft spans or Loc-Nall shall achieve an average withdrawal of Poly SMS Base ES Products 9-Inch o.c. In two, equally spaced, SBS-SA-H SBS-TA or -75.0 structural 110 lbf when tested per TAS 105 or ANSrISPRI Twin Loc-Nall staggered center rows APP-TA concrete FX-1 Exterior Research and Design, I-I-C. d/b/a Trinity[ERD Evaluation Report 3520.03.04-115 for FI-2533-115 Certificate of Authorization #9503 Revision 5: 04/26/2011 Prepared by: Robert Nlemlnen, PE-59166 Appendix 1, Page 27 of 40 TKINITY il ERD TABLE 4C: LIGHTWEIGHT CONCRETE DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Deck (See Note 1) Base Sheet Roof Cover No. Structural Deck Lightweight Concrete Type Fasteners Attach Ply Cap p S; CONVENTIONAL SYSTEMS: Min. 26 ga. Glasbase; Flexiglas ES Products steel at max Min. 200 psi, min 2-Inch thick Range II Elastizell Base; Flintlastic Base FM-90 Base Ply Fasteners 71/2-inch o.c. at the 4-Inch lap and BP -AA, SBS-AA, SBS-AA, LWC-26 5 It spans or Ughtwelght Insulating Concrete. 20; All Weather or Twin Loc- 71/2-Inch o.c. in two, equally SBS-TA or SBS-TA or -30.0 structural Empire Base; Poly SMS Nails (1 . 8 spaced, staggered center rows APP-TA APP-TA concrete Base; Yosemite inch) Min. 22 ga. Glasbase; Flexiglas ES Products steel at max Min. 200 psi, min 2-Inch thick Range II Elastizell Base; Flintlastic Base FM-90 Base Ply Fasteners 7-Inch o.c. at the 4-inch lap and BP -AA, SBS-AA SBS-AA, -45.0 LWC-27 5 It spans or Lightweight Insulating Concrete. 20; All Weather/ or Twin Loc- 7-inch o.c. In two, equally spaced, SBS-TA or SBS-TA or structural Empire Base; Poly SMS Nails (1 . 8 staggered center rows APP-TA APP-TA concrete Base; Yosemite Inch) Min. 22 ga. Glasbase; Flexlglas steel at max Base; Flintlastic Base OMG CR Base 7-Inch o.c. at the 4-Inch lap and BP -AA or SBS-AA, LWC-28 5 ft spans or Min. 250 psi, min 2-Inch thick Mearicrete. 20; All Weather / Ply Fasteners 7-Inch 6.c. In two, equally spaced, SBS-TA or -45.0 structural Empire Base; Poly SMS (1.7) staggered center rows SBS-AA APP-TA concrete Base; Yosemite Min. 22 ga. Glasbase; Flexiglas steel at max Base; FlIntlastic Base Simplex Base- 9-inch o.c. at the 4-Inch lap and BP -AA or SBS-AA, LWC-29 5 ft spans or Min. 250 psi, min 2-Inch thick Mearlcrete. 20; All Weather/ Lok Fasteners 9-Inch o.c. In two, equally spaced, SBS-AA SBS-TA or -45.0 structural Empire Base; Poly SIVIS staggered center rows APP-TA concrete Base; Yosemite Min. 22 ga. steel at max OMG CR Base 7-Inch o.c. at the 4-Inch lap and SBS-AA, LWC-30 5 ft spans or Min. 250 psi, min 2-Inch thick MearIcrete. Poly SMS Base Ply Fasteners 7-inch o.c. in two, equally spaced, BP -AA or SBS-TA or -52.5 structural (1.7) staggered center rows SBS-AA APP-TA concrete Min. 22 ga. steel at max Simplex Base- 9-Inch c.c. at the 4-Inch lap and BP -AA or SBS-AA, LWC-31 5 ft spans or Min. 250 psi, min 2-inch thick Mearicrete. Poly SMS Base Lok Fasteners 12-Inch o.c. In two, equally SBS-AA SBS-TA or -52.5 structural spaced, staggered center rows APP-TA concrete Min. 22 ga. Glasbase; Flexiglas steel at max Base; Flintlastic Base OMG CR Base 7-Inch o.c. at the 4-Inch lap and BP -AA or SBS-AA, LWC-32 S ft spans or Min. 300 psi, min 2-Inch thick Mearlcrete. 20; All Weather / Ply Fasteners 7-inch o.c. In two, equally spaced, SBS-TA or -52.5 structural Empire Base; Poly SMS (1.7) staggered center rows SBS-AA APP-TA concrete Base; Yosemite Min. 22 ga. Glasbase; Flexiglas steel at max Concrecel Bonding Agent on deck; Min. 300 psi, Base; FlIntlastic Base OMG CR Base 7-Inch o.c. at the 3-Inch lap and BP -AA or SBS-AA, LWC-33 5 it spans or min 2V4-Inch thick Concrecel Concrete. 20; All Weather / Ply Fasteners 7-Inch o.c. In two, equally spaced, SBS-AA SBS-TA or structural Empire Base; Poly SMS (1.7) staggered center rows APP-TA concrete Base; Yosemite Exterior Research and Design, LLC. d/b/a TrInItVjERD Evaluation Report 3520.03.04-115 for FL2533-RS Certificate of Authorization #9503 Revision 5: 04/26/2011 Prepared by: Robert Nlemlnen, PE-59166 Appendix 1, Page 28 of 40 . 2, '-,JTR1N1TY.1ERQ TABLE 4C: LIGHTWEIGHT CONCRETE DECKS - NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Deck (See Note 1) Base Sheet Roof Cover No. Structural Deck Lightweight Concrete Type Fasteners Attach Ply Cap MDP (PSf) Min. 22 ga. Min. 300 psi, min. 2-inch thick Approved cellular Glasbase; Flexiglas steel at max lightweight Insulating concrete. Note: To qualify Base; Flintlastic Base Min. 1.8-Inch 9-Inch o.c. at the 4-Inch lap and BP-AA1 SBS-AA, LWC-34 5 ft spans or the LWIC under this assembly, a 1.8-Inch Twin Loc-Nail shall achieve an average withdrawal of 201* All Weather/ ES Products 9-Inch o.c. in two, equally spaced, SBS-AA, SBS-TA or SBS-TA or -60.0 structural 88 lbf when tested per TAS 105 or ANSIISPRI Empire Base; Twin Loc-Nall staggered center rows APP-TA APP-TA concrete FX-1 Yosemite Min. 22 ga. Min. 300 psi, min. 2-Inch thick Approved cellular Glasbase; Flexiglas steel at max lightweight Insulating concrete. Note: To qualify the LWIC under this assembly, a 1.8-Inch Twin Base; Flintlastic Base Min. 1.8-Inch 7-Inch o.c. at the 4-inch lap and BP -AA or SBS-AA, LWC-35 5 ft spans or Loc-Nall shall achieve an average withdrawal of 20; All Weather ES Products 7-Inch o.c.-In two, equally spaced, SBS-AA SBS-TA or -67.5 structural 77 Ibl' when tested per TAS 105 or ANSIISPRI Empire Base; Twin Loc-Nall staggered center rows APP-TA concrete FX-1 Yosemite Min. 22 ga. Min. 350 psi, min. 3-Inch thick Approved cellular steel at max lightweight Insulating concrete. Note: To qualify the LWIC under this assembly, a 1. 8-inch Twin Flexiglas Base; Flintlastic Base 20; ES Products 7-Inch o.c. at the 4-inch lap and BP-AA1 SBS-AA, SBS-AA, LWC-36 5 ft spans or Loc-Nall shall achieve an average withdrawal of Poly SMS Base; FM-90 Base 10-Inch o.c. In two, equally SBS-TA or SBS-TA or -67.5 structural. 97 1& when tested per TAS 105 or ANSIISPRI Yosemite Ply Fasteners spaced, staggered center rows APP-TA APP-TA concrete FX-1 Min. 22 ga. Min. 300 psi, min. 2-Inch thick Approved cellular steel at max lightweight Insulating concrete. Note: To qualify the LWIC under this assembly, a I.B-16ch Twin Poly SMS Base; Ultra Min. 1.8-inch 9-inch o.c. at the 4-Inch lap and BP-AA1 SBS-AA, SBS-AA, LWC-37 5 ft spans or Loc-Nafl shag achieve an average withdrawal of Poly SMS Base ES Products 9-Inch o.c. In two, equally spaced, SBS-TA or SBS-TA or -75.0 structural 110 lbf when tested per TAS 105 or ANSrISPRr Twin Loc-Nall staggered center rows APP-TA APP-TA concrete FX-1 Min. 22 ga. Glasbase; Flexiglas steel at max Min. 300 psi, min 2-Inch thick Celcore Cellular Base; Flintlastic Base ES Products 7-Inch o.c. at the 3-Inch lap and SBS-AA, LWC-38 S ft spans or Concrete. After setting to support foot traffic, 20; All Weather/ FM-90 Base 7-Inch o.c. In two, equally spaced, BP -AA or SBS-TA or -75.0 structural Celcore PVA Curing Compound Is applied. Empire Base; Poly SMS Ply Fasteners staggered center rows SBS-AA APP-TA concrete Base; Yosemite COLD APPLIED SYSTEMS: Min. 22 ga. steel at max Min. 350 psi, min 2-inch thick Range II Elastizell FlIntlastic Base 20; ES Products 7-Inch o.c. at the 4-Inch lap and (Optional) LWC-39 5 ft spans or Lightweight Insulating Concrete with Zell Fibers. Poly SMS Base FM-90 Base 7-Inch o.c. In two, equally spaced, BP-CA2 or SBS-CA2 -45.0 structural Ply Fasteners staggered center rows SBS-CA2 concrete Min. 22 ga. Min. 350 psi, min 2-Inch thick Range II Elastizell Glasbase; Flexiglas ES Products 7-Inch o.c. at the 4-Inch lap and (Optional) LWC-40 steel at max Ughtwelght Insulating Concrete with Zell Fibers. Base; Poly SMS Base FM-90 Base 7-Inch o.c. In two, equally spaced, BP-CA3 or SBS-CA3 -52.5 5 ft spans Ply Fasteners staggered center rows SBS-CA3 r ctural St u Min. 350 psi, min 2-inch thick Range 11 Elastizell Glasbase; Flexiglas ES Products 7-:nch o.c. at the 4-inch lap and (Optional) LWC-41 concrete Lightweight Insulating Concrete with Zell Fibers. Base; Poly SMS Base FM-90 Base 7- nch o.c. In two, equally spaced, BP-CA3 or SBS-CA3 Ply Fasten-r-q staggered center rows SBS-CA3 I Exterior Research and Design, LLC. d/b/a TrInItyjERD Evaluation Report 3520.03.04-115 for FL2533-RS Certificate of Authorization #9503 Revision 5: 04/26/2011 Prepared by: Robert Nleminen, PE-59166 Appendix 1, Page 29 of 40 TRINITY ERD TABLE SA: CEMENTITIOUS WOOD FIBER DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System Base Insulation Layer Top Insulation Layer Roof Cover No. Deck I MDP (psf) Type Attach Type Attach Base Ply Cap SELF -ADHERING SYSTEMS: Min. 1/4-inch DensDeck primed CWF-1. Tectum Min. 1.5-inch FlintBoard ISO, ACFoam II, ENRGY OB500 with FlintPrime SA; DensDeck OB500 SBS-SA (Optional) SBS-SA -45.0* 3 or Multi -Max FA3 DuraGuard or SECUROCK SBS-SA Gypsum -Fiber Roof Board Min. 1.0-inch ISO 95+ GL, H-Shleld, H-Shleld CG, Min. 1/4-inch DensDeck primed CWF-2. Tecturn ENRGY 3 or JM ISO 3 min. 1.3-inch ACFoam III, CR-20 with FlintPrime SA; DensDeck CR-20 SBS-SA (Optional) SBS-SA -52.5 Min. 1.5-Inch Multi -Max FA3 or Ultra -Max or min. DuraGuard or SECUROCK SBS-SA 2.0-inch ACFoam IV Gypsum -Fiber Roof Board CONVENTIONAL SYSTEMS: CWF-3. Tecturn Min. 1.5-inch FlintBoard ISO, ACFoam II, ENRGY OB500 Min. 1/2-inch Structodek High OB500 BP -AA or (Optional) BP -AA, SBS- SBS-AA, SBS-TA -45.0* 3 or Multi -Max FA3 Density Fiberboard SBS-AA AA, SBS-TA or APP-TA or APP-TA Min. 1.5-Inch FlintBoard ISO, ACFoam 11, ENRGY Min. 7/4-Inch SECUROCK BP -AA, SBS-AA, (Optional) BP -AA, SBS SBS-AA, CWF-4. Tecturn 3 or Multi -Max FA3 OB500 Gypsum -Fiber Roof Board or OBSOO SBS-TA or AA, SBS-TA SBS-TA -45.0* DensDeck or DensDeck Prime APP-TA or APP-TA or APP-TA Min. 1.0-inch ISO 95+ GL, H-Shleld, H-Shleld CG, Min. 1/2-inch Structodek High (Optional) CWF-5. Tecturn ENRGY 3 or JM ISO 3 min. 1.3-inch ACFoam III I CR-20 Density Fiberboard or OuraBoard (homogeneous) or CR-20 BP_AA or BP -AA SBS- SBS-AA1 SBS-TA -52.5 Min. 1.5-inch Multi -Max FA3 or Ultra -Max or min. min. 1.5-Inch FescoBoard SBS-AA AA, S9S-TA or APP-TA 2.0-inch ACFoam IV (laminated) or APP-TA Min. 1.0-inch ISO 95+ GL, H-Shleld, H-Shield CG, Min. 1/4-inch SECUROCK BP-AA1 (Optional) SBS-AA, CWF-6. Tectum ENRGY 3 or IM ISO 3 min. 1.3-inch ACFoam III CR-20 Gypsum -Fiber Roof Board or CR-20 SBS-AA, E I IP-AA SBS- SBS-TA -52.5 Min. 1.5-inch Multi -Max FA3 oir Ultra -Max or min'. DensDeck or DensDeck Prime SBS-TA or AA, SBS-TA or APP-TA I I 2.0-inch ACFoam IV I APP-TA or APP-TA Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report 3520.03.04-R5 for FL2533-R5 Certificate of Authorization #9503 Revision 5: 04/26/2011 Prepared by: Robert Nleminen, PE-59166 Appendix 1, Page 30 of 40 \,,J TRINITY ERD TABLE 5B: CEMENTITIOUS WOOF FIBER DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER Deck Anchor Sheet Base Insulation Top Insulation Roof Cover System (See MDP NO. Note 1) Type Fasteners Attach Type Attach Type Attach Base Ply T Cap Psf) HYBRID SYSTEMS: Glasbase; Flexiglas Base; 7-Inch o.c. at the 4- Min. 1.5-inch (Optional) Flintlastic Base Min. 1.8-inch Inch lap and 7-Inch ACFoam II, SBS-AA, SBS-AA, CWF-7. Tecturn 20; All Weather/ ES Products o.c. In two, equally FlIntBoard ISO, HA None N/A SBS-SA-H SBS-TA or SBS-TA or -60.0 Empire Base; Twin Loc-Nall spaced,staggered ENRGY 3 or Multi- APP-TA APP-TA Yosemite center rows Max FA3 CONVENTIONAL SYSTEMS: 9-Inch o.c. at the 4- (Optional) Min. Min. -Y4-Inch All Weather/ Insuldeck Loc- Inch lap and 12-Inch 1.5-Inch ACFoam FescoBoard (homogeneous) or BP -AA or (Optional) SBS-AA, CWF-8. Tecturn Empire Base; Nails o.c. In two, equally II, FlIntBoard ISO, HA min. 1/2-Inch HA SBS-AA BP -AA or SBS-TA or -30.0* Yosemite spaced, staggered ENRGY 3 or Multi- Structodek High SBS-AA APP-TA center rows Max FA3 Density Fiberboard 71/2-Inch o.c. at the (Optional) Min. Min. 3/4-inch 'All Weather/ Insuldeck Loc- 4-Inch lap and 71/2- Inch o.c. in two, 1.5-Inch ACFoarn FescoBoard (homogeneous) or BP -AA or (Optional) SBS-AA, CWF-9. Tecturn Empire Base; Nails equally spaced, II, FlintBoard ISO, HA min. 1/2-Inch HA SBS-AA BP -AA or SBS-TA or -45.0* Yosemite staggered center ENRGY 3 or Multi- Structodek High SBS-AA APP-TA rows Max FA3 Density Fiberboard Glasbase; Flexiglas Base; 7-Inch o.c. at the 4- Min. 1.5-inch Min. 3/4-Inch FescoBoard CWFF-10. Flintlastic Base Min. 1.8-Inch Inch lap and 7-Inch ACFoam II (homogeneous) or BP -AA or (Optional) SBS-AA, Tecturn 20; All Weather ES Products o.c. In two, equally FlintBoard ISO, HA min. 1/2-Inch HA SBS-AA BP -AA or SBS-TA or -60.0 Empire Base; Twin Loc-Nall spaced, staggered ENRGY 3 or Multi- Structodek High SBS-AA APP-TA Yosemite center rows Max FA3 Density Fiberboard Exterior Research and Design, LLC. d/b/a TrInItyjERD Evaluation Report 3520.03.04-RS for FL2533-R5 Certificate of Authorization #9503 Revision 5: 04/26/2011 Prepared by: Robert Nlemlnen, PE-59166 Appendix 1, Page 31 of 40 TRINITY ERD TABLE SC: CEMENTITIOUS WOOD FIBER DECKS — NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System Deck Base Insulation Top Insulation Layer Roof Cover No. (See Note 1) Layer(s) MDP (psf) Type Fasteners Attach Base Ply Cap CWF-11. Tecturn (Optional) One or more layers, any Min. 1/2-inch I'M Approved high density OMG Polymer GypTec 1 per 2 ft2 BP -AA or SBS- (Optional) BP - AA, SBS-AA, SBS-AA, SBS-TA or -45.0* combination, wood fiberboard with 3" GypTec Plate AA SBS-TA or APP- APP-TA loose laid TA CWF-12. Tecturn (Optional) One or more layers, any Min. 1/4-Inch DensDeck OMG Polymer GypTec 1 per 1.78 BP -AA SBS- (Optional) BP- AA, SBS-AA, SBS-AA, combination, or DensDeck Prime with 3" GypTec Plate ft 2 AA, S9S-TA or SBS-TA or APP- SBS-TA or -45.0* loose laid APP-TA TA APP-TA (Optional) One or Min. 1/2-inch FM ES Products Twin Loc- (Optional) BP- SBS-AA, CWF-13. Tecturn more layers, any combination, Approved high density Nails (minimum 1- Inch embedment Into 1 per 2 ft2 BP -AA or SBS- AA AA, SBS-AA, SBS-TA or APP- SBS-TA or -45.0* loose laid wood fiberboard deck) TA APP-TA (Optional) One or Min. 1/4-inch DensDeck ES Products Twin Loc- BP -AA, SBS- (Optional) BP- SBS-AA, CWF-14. Tecturn more layers, any combination, E' or DensDeck Prime or SECUROCK Gypsum- Nails (minimum 1- Inch embedment Into 1 per 2 ft2 AA, SBS-TA or AA, SBS-AA, SBS-TA or APP- SBS-TA or -45.0* loose laid I Fiber Roof Board I deck) I APP-TA TA APP-TA TABLE SD: CEMENTrTOUS WOOD FIBER DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Deck Base Sheet Roof Cover No. I (See Note 1) MOP (psf) Base Fasteners Attach ply cap SELF -ADHERING SYSTEMS: CWF-15. Tecturn FlIntlastic SA NallBase I Min. 1.8-Inch ES Products Twin Loc- I 7-Inch o.c at the 4-Inch lap and 7-11n ch o.c. In SBS-SA SBS-SA T -60.0 Nall two, equaily spaced, staggered center rows CONVENTIONAL SYSTEMS: CWF-16. Tecturn All Weather/ Empire Base; ES Products 9-1hch o.c. at the 4-Inch lap and 12-Inch o.c. in BP -AA or SBS- Yosemite Insuldeck Loc-Nalls two, equally spaced, staggered center rows AA SBS-AA -30.0* CWF-17. Tecturn All Weather/ Empire Base; ES Products 71/2-inch o.c. at the 4-Inch lap and 71/2-inch o.c. BP -AA or SBS- Yosemite Insuldeck Loc-Nalls In two, equally spaced, staggered center rows AA SBS-AA -45.0* CWF-18. Tecturn Glasbase; Flexlglas Base,, All Weather/ Empire Base; Simplex Turbo Tube- 9-Inch o.c. at the 4-Inch lap and 12-Inch o.c. In SBS-AA, SBS- SBS-AA, Yosemite Lok two, equally spaced, staggered center rows TA or APP-TA SBS-TA or -45.0* APP-TA CWF-19. Tecturn Glasbase; Flexiglas Base-, Flintlastic Base 20 or All, Min. 1.8-inch ES Products Twin Loc- 7-Inch o.c. at the 4-inch lap and 7-Inch o.c. In BP -AA or SBS- SBS-AA, Weather / Empire Base; Nail two, equally spaced, staggered center rows AA SBS-TA or -67.5 Yosemite APP-TA Exterior Research and Design, LLC. d/b/a TrInItyjERD Evaluation Report 3520.03.04-R5 for FL2533-115 Certificate of Authorization #9503 Revision 5: 04/26/2011 Prepared by: Robert Nlemlnen, PE-59166 Appendix 1, Page 32 of 40 JTRINITYIERD i TABLE 6A: GYPSUM DECKS - REROOF (Tear -Off) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System Base Insulation Layer Top Insulation Layer Roof Cover No. Deck I MDP(psf) Type Type Attach Base Ply Cap SELF -ADHERING SYSTEMS: G-1. Existing sound gypsum or Min. 1.5-inch FlintBoard ISO, ACFoam II, ENRGY M-OSFA Min. 1/4-inch DensDeck M-OSFA SBS-SA (Optional) SBS-SA -105.0 gypsum plank 3 or Multi -Max FA3 DuraGuard SBS-SA G-2. Existing sound gypsum or 1-1 -in. 1.5-inch ACFoam II, FlintBoard, ENRGY 3 M-OSFA Min. 1/4-inch SECUROCK M-OSFA SBS-SA (Optional) SBS-SA -172.5 gypsum plank or H-Shleld Gypsum -Fiber Roof Board SBS-SA G-3. Existing sound gypsum or Min 1.S-Inch ACFoam II, FlintBoard, ENRGY 3 �ultl-Max M-OSFA Min. 1/4-Inch DensDeck primed M-OSFA SBS-SA (Optional) SBS-SA -192.5 gypsum plank or FA with FlintPrime SA SBS-SA G-4. Existing sound gypsum or Min. 1.5-inch FlintBoard ISO, ACFoam II, ENRGY OB500 Min. 1/4-Inch DensDeck OB500 SBS-SA (Optional) SBS-SA -105.0 gypsum plank 3 or Multi -Max FA3 DuraGuard SBS-SA Existing sound Min. 1/4-inch DensDeck primed G-5. gypsum or Min. 1.5-inch ACFoam II, FlintBoard ISO or OB500 with FlintPrime SA or OB500 SBS-SA (Optional) SBS-SA -135.0 gypsum plank ENRGY 3 SECUROCK Gypsum -Fiber SBS-SA Roof Board Existing sound Min. 1.0-inch ISO 95+ GL, H-Shleld, H-Shleld G-6. gypsum or CG, ENRGY 3 or IM ISO 3 min. 1.3-inch ACFoam CR-20 Min. 1/4-inch DensDeck CR-20 SBS-SA (Optional) SBS-SA -105.0 gypsum plank III, Min. 1.5-inch Multi -Max FA3 or Ultra -Max or DuraGuard SBS-SA min. 2.0-inch ACFoam IV Existing sound Min. 1.0-inch ISO 95+ GL, H-Shleld, H-Shield G-7. gypsum or CG, ENRGY 3 or JM ISO 3 min. 1.3-inch ACFoa m CR-20 Min. 1/4-Inch SECUROCK CR-20 SBS-SA (Optional) SBS-SA -172.5 gypsum plank III, Min. 1.5-inch Multi -Max FA3 or Ultra -Max or Gypsum -Fiber Roof Board SBS-SA min. 2.0-inch ACFoam IV Existin g sound Min. 1.0-Inch ISO 95+ GL, H-Shleld, H-Shleld G-8. gypsum or CG, ENRGY 3 or 3M ISO 3 min. 1.3-inch ACFoam CR-20 Min. 1/4-inch DensDeck primed CR-20 SBS-SA (Optional) SBS-S,]A -192.5 gypsum plank III, Min. 1.5-inch Multi -Max FA3 or Ultra -Max or with FlintPrime SA SBS-SA min. 2.0-inch ACFoam IV CONVENTIONAL SYSTEMS: Existing sound (Optional) SBS-AA, G-9. gypsum or Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY M-OSFA Min. 1/2-inch Structodek High M-OSFA BP -AA or BP -AA, SBS- SBS-TA -127.5 gypsum plank 3 or H-Shield Density Fiberboard SBS-AA AA, SBS-TA or APP- or APP-TA TA Existing sound (Optional) SBS-AA, G-10. gypsum or Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 H-Shleld M-OSFA Min. 1/4-inch DensDeck M-OSFA BP -AA or BP -AA, SBS- SBS-TA -232.5 gypsum plank or SBS-AA AA, SBS-TA or APP- or APP-TA TA Existing sound BP -AA or (Optional) SBS-AA, G-11. gypsum or Min. 2-Inch ACFoam II, FlintBoard ISO, ENRGY 3 M-OSFA Min. 1/4-inch SECUROCK M-OSFA SBS-AA, BP -AA, SBS- SBS-TA -202.5 gypsum plank or H-Shield 1 Gypsum -Fiber Roof Board SBS-TA or AA, SBS-TA or APP- 1 1 APP-TA or APP-TA TA Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report 3520.03.04-115 for FL2533-RS Certificate of Authorization #9503 Revision 5: 04/26/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 33 of 40 RI-NITY'ERD t TABLE 6A: GYPSUM DECKS - REROOF (Tear -Off) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System Base Insulation Layer Top Insulation Layer Roof Cover No. Deck MDP (psf) Type Attach Type' Attach Base Ply Cap Existing sound (Optional) SBS-AA, G-12. gypsum or Min. 1.5-Inch ACFoam II, FlintBoard ISO, ENRGY OB500 Min. I/z-inch Structodek High OB500 BP -AA or BP -AA, SBS- SBS-TA -120.0 gypsum plank 3 or H-Shield Density Fiberboard SBS-AA AA, SBS-TA or APP- or APP-TA TA Existing sound Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY Min. 1/4-Inch DensDeck, BP -AA, SBS-AA, (Optional) BP -AA, SBS- SBS-AA, SBS-TA G-13. gypsum or gypsum plank 3 or H-Shleld OB500 DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board OB500 SBS-TA or AA, SBS-TA or APP- -135.0 APP-TA or APP-TA TA Existing sound Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shleld G-14. gypsum or CG, ENRGY 3 or JM ISO 3 min. 1.3-inch ACFoa m CR-20 1/4 Min. -inch DensDeck or CR-20 SBS-TA (Optional) SBS-TA -180.0 gypsum plank III, Min. 1.5-inch Multi -Max FA3 or Ultra -Max or DensDeck Prime SBS-TA min. 2.0-inch ACFoam IV Existing sound Min. 1.0-inch ISO 95+ GL, H-Shleld, H-Shield Min. I/z-lnch Structodek High Density Fiberboard or (Optional) SBS-AA, G-15. gypsum or CG, ENRGY 3 or JM ISO 3 min. 1.3-inch ACFoam CR-20 DuraBoard (homogeneous) or CR-20 BP -AA or BP -AA, SBS- SBS-TA -180.0 gypsum plank III ' Min. 1.5-inch Multi -Max FA3 or Ultra -Max or min. 1.5-inch FescoBoard SBS-AA AA, SBS-TA or APP- min. 2.0-inch ACF.am IV (laminated) or APP-TA TA Existing sound Min. 1.0-inch ISO 95+ GL, H-Shleld, H-Shield (Optional) SBS-AA, G-16. gypsum or CG, ENRGY 3 or 3M ISO 3 min. 1.3-inch ACFoam CR-20 Min. 1/4-inch SECUROCK CR-20 BP -AA or or -AM, 5,15S- SBS-TA -225.0 gypsum plank III, Min. 1.5-inch Multi -Max FA3 or Ultra -Max or Gypsum -Fiber Roof Board SBS-AA AA, SBS-TA or APP- min. 2.0-inch ACFoam IV or APP-TA TA Existing sound Min. 1.0-inch ISO 95+ GL, H-Shleld, H-Shleld (Optional) SBS-TA G-17. gypsum 0 r CG, ENRGY 3 or 3M ISO 3 min. 1.3-inch ACFoam CR-20 Min. 1/4-inch SECUROCK CR-20 SBS-TA or SBS-TA or or APP- -232.5 gypsum plank III ' Min. 1.5-inch Multi -Max FA3 or Ultra -Max or Gypsum -Fiber Roof Board APP-TA APP-TA min. 2.0-inch ACFoam IV TA Existing sound Min. 1.0-inch ISO 95+ GL, H-Shleld, H-Shiel (Optional) SBS-AA, G-18. gypsum or CG " ENRGY 3 or JM ISO 3 min. 1.3-inch ACFoam CR-20 Min. 1/4-inch DensDeck CR-20 BP_AA or BP -AA, SBS- SBS-TA -240.0 gypsum plank III, Min. 1.5-Inch Multi -Max FA3 or Ultra -Max or SBS-AA AA, SBS-TA or APP- min. 2.0-inch ACFoam IV or APP-TA TA Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report 3520.03.04-RS for FL2533-RS Certificate of Authorization #9503 Revision 5: 04/26/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 34 of 40 TRINITY'ERD TABLE 6B: GYPSUM DECKS — REROOF (Tear -Off) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER system Deck Anchor Sheet Base Insulation Top insulation Roof Cover MOP Type Fasteners ch Type Attach Type A ch Base Cap No. (See Note 1) I (Psf) HY13RID SYSTEMS: Glasbase; 7-Inch o.c. at the Min. 1.5-Inch Existing sound Flexiglas Base; Min. 1.8-inch 4-Inch lap and 7- ACFoam II, (Optional) SBS-AA, G-19. gypsum or Flintlastic Base 20; All Weather ES Products inch o.c. In two, equally spaced FlintBoard ISO, HA None N/A SBS-SA-H SBS-AA, SBS-TA or SBS-TA or -60.0 gypsum plank / Empire Base; Twin Loc-Nall staggered cenier ENRGY 3 or Multi- APP-TA APP-TA Yosemite rows Max FA3 CONVENTIONAL SYSTEMS: 9-Inch o.c. at the Min. :144-Inch ES Products 4-Inch lap and IS- (Optional) Min. 1.5- FescoBoard Existing sound All Weather/ FM-75 or PM-90 inch o.c. In two Inch ACFoam II, (homogeneous) or BP -AA or (Optional) SBS-AA, G-20. gypsum or Empire Base; Base Ply equally spaced, FlintBoard ISO, HA min.1/2-Inch HA SBS-AA BP -AA or SBS-TA or -45.0* gypsum plank Yosemite Fasteners staggered center ENRGY 3 or Muld- Structodek High SBS-AA APP-TA Max FA3 Density rows Fiberboard Glasbase; 7-Inch o.c. at the Min. 1.5-Inch Min. V4-inch FescoBoard Existing sound Flexiglas Base; Flintlastic Base Min. 1.8-Inch 4-inch lap and 7- Inch o.c. In two, ACFoam II, (homogeneous) or BP -AA or (Optional) SBS-AA G-21. gypsum or 20; All Weather ES Products equally spaced FlintBoard ISO, HA min. 1/2-inch HA SBS-AA BP -AA or SBS-TA or -60.0 gypsum plank / Empire Base; Twin Loc-Nall j'e staggered cen r. ENRGY 3 or Multi- Structodek High SBS-AA APP-TA Yosemite rows Max FA3 Density I I I Fiberboard Exterior Research and Design, LLC. d/b/a TrInItylERD Evaluation Report 3520.03.04-115 for FL2533-R5 Certificate of Authorization #9503 Revision 5: 04/26/2011 Prepared by: Robert Nleminen, PE-59166 Appendix 1, Page 35 of 40 4 . ---,JTR1N1TYjERD TABLE 6C: GYPSUM DECKS — REROOF (Tear -Off) SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System Deck Base Insulation Top Insulation Layer Roof Cover No. (See Note 1) Layer(s) MDP (psf) Type Fasteners Attach Base Ply Cap G-22. Existing sound gypsum or (Optional) One or more layers' any Min. 1/2-Inch FM Approved high density OMG Polymer GypTec 1 per 2 BP_AA or SBS- (Optional) BP- AA, SBS-AA SBS-AA, SBS-TA or -45.0* gypsum plank combination, wood fiberboard with 3" GypTec Plate AA SBS-TA or XPP- APP-TA loose laid TA Existing sound (Optional) One or more layers, any Min. 1/4-Inch DensDeck OMG Polymer GypTec I per 1.78 BP -AA SBS- '(Optional) BP- AA SBS-AA, SBS-AA, G-23. gypsum or gypsum plank combination, or DensDeck Prime with 3" GypTec Plate ft 2 AA, S9S-TA or APP-TA , SBS-TA or APP- SBS-TA or APP-TA -45.0* loose laid TA Existing sound (Optional) One or Min. 1/2-Inch FM ES Products Twin Loc- (Optional) BP- SBS-AA, G-24. gypsum or more layers, any combination, Approved high density Nails (minimum 1- Inch embedment Into 1 per 2 ft2 BP -AA or SBS- AA AA, SBS-AA, SBS-TA or APP- SBS-TA or -45.0* gypsum plank loose laid wood fiberboard deck) TA APP-TA Existing sound (Optional) One or Min. 1/4-Inch DensDeck ES Products Twin Loc- BP -AA SBS- (Optional) BP- SBS-AA, G-25. gypsum or more layers, any or DensDeck Prime or Nails (minimum I- 1 per 2 ft? AA SBS-TA or AA, SBS-AA, SBS-TA or -45.0* gypsum plank combination, SECUROCK Gypsum- Inch embedment Into ' APP-TA SBS-TA or APP- APP-TA loose laid Fiber Roof Board deck) TA I TABLE 6D: GYPSUM DECKS — REROOF (Tear -Off) SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Deck Base Sheet Roof Cover No. (See Note 1) MDP (psf) Base Fasteners Attach ply cap SELF -ADHERING SYSTEMS: Existing sound gypsum or Min. 1.8-Inch ES 9-Inch o.c. at the 4-Inch lap and 9- G-26. F9yX pl� sum plank Flintlastic SA NallBase Products Twin Inch o.c. In two, equally spaced, SBS-SA SBS-SAA -60.0 Loc-Nall staggered center rows CONVENTIONAL SYSTEMS: G-27. Existing sound gypsum or All Weather/ Empire Base; ES Produ cts FM- 75 or FM-90 Base 9-Inch o.c. at the 4-Inch lap and 18- inch o.c. In two, equally spaced, BP -AA or SBS- SBS-AA -45.0* gypsum plank Yosemite Ply Fasteners staggered center rows AA Existing sound gypsum or Glasbase; Flexiglas Base; All S Implex Turbo 9-Inch o.c. at the 4-Inch lap and 12- SBS.-AA, SBS-TA SBS-AA, G-28. gypsum plank Weather/ Empire Base; Tube-Lok Inch o.c. In two, equally spaced, or APP-TA SBS-TA or -45.0* Yosemite staggered center rows APP-TA Existing sound gypsum or Glasbase; Flexiglas Base; Flintlastic Base 20; All Min. 1.8-inch ES 9-Inch o.c. at the 4-Inch lap and 9- BP -AA or SBS- SBS-AA, G-29. gypsum plank Weather/ Empire Base; Products Twin Inch o.c. In two, equally spaced, AA SBS-TA or -67.5 I I Yosemite Loc-Nall I staggered center rows APP-TA Exterior Research and Design, LLC. d/b/a TrInItyjERD Evaluation Report 3520.03.04-115 for FL2533-R5 Certificate of Authorization #9SO3 Revision 5: 04/26/2011 Prepared by: Robert Nlemlnen, PE-59166 Appendix 1, Page 36 of 40 k . 6 10 _" 4 . \JTRINITYERD TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A., BONDED INSULATION, BONDED ROOF COVER System Substrate (See I Base Insulation Layer Top Insulation Layer Roof Cover N Notes I & 11) MDP (psf) Type Attach Type Attach Bass _IPly__ _7­&-_P_� SELF -ADHERING SYSTEMS: Existing fully Min. 1/4-inch DensDeck bonded BUR or Min. 13-Inch ACFoarn II, FlintBoard primed with FlintPrime SA; R-1 modified bitumen ISO, ENRGY 3, H-Shleld or Multi -Max HA DensDeck DuraGuard; or HA SBS-SA (Optional) SBS- SBS-SA -105.0 roof cover FA3 SECUROCK Gypsum -Fiber SA Roof Board. Existing fully Min. 1/4-inch DensDeck R-2 bonded, smooth Min. 1.5-inch ACFoam 11, FlintBoard, A-PD primed with FlintPrime SA A-PD (Optional) SBS- surface BUR or ENRGY 3 or Multi -Max FA3 6-inch o.c. or SECUROCK Gypsum- 6-inch o.c. SBS-SA SA SBS-SA -52.5 modified bitumen Fiber Roof Board Existing fully Min. 1/4-inch DensDeck R-3 bonded, mineral Min. 1.5-inch ACFoam 11, FlintBoard, A-PD primed with FlintPrime SA A-PD (Optional) SBS- surface BUR or ENRGY 3 or Multi -Max FA3 6-Inch o.c. or SECUROCK Gypsum- 6-Inch o.c. SBS-SA SA SBS-SA -172.5 modified bitumen Fiber Roof Board Existing fully R-4 bonded BUR or modified bitumen Min. 1.5-inch ACFoam 11, FlintBoard, ENRGY 3 or Multi -Max FA M-PFIA Min. 1/4-Inch Densbeck primed with FlintPrime SA M-PFIA SBS-SA (Optional) SBS- SBS-SA -135.0 roo cover SA Existing fully R-5 bonded BUR or Min. 1.5-inch FlintBoard ISO, ACFoarn M-OSFA or Min. 1/4-inch DensDeck M-OSFA or (Optional) SBS- modified bitumen II, ENRGY 3 or Multi -Max FA3 M-PG1 DuraGuard M-PG1 SBS-SA SA SBS-SA -105.0 roofcover Existing fully R-6 bonded BUR or modified bitumen Min. 1.5-inch ACFoam II, FlintBoard, ENRGY 3 or H-Shield M-OSFA Min. 1/4-inch SECUROCK Gypsum -Fiber Roof Board M-OSFA SBS-SA (Optional) SBS- SBS-SA -157.5 roo cover SA Existing fully R-7 bonded BUR or Min. 1.5-inch ACFoam 11, FlintBoard, M-PG1 Min. 1/4-inch SECUROCK (Optional) SBS- modified bitumen ENRGY 3 or H-Shleld Gypsum -Fiber Roof Board M-PG1 SBS-SA SA SBS-SA -172.5 roof cover Existing fully R-8 bonded BUR or modified bitumen Min. 1.5-inch ACFoam 11, FlintBoard, ENRGY 3 or Multi -Max FA M-OSFA Min. 1/4-inch DensDeck primed with FlintPrime SA M-OSFA SBS-SA (Optional) SBS� SBS-SA -157.5 roofcover SA Existing fully R-9 bonded BUR or Min. 1.5-inch ACFoam II, FlintBoard, M-PG1 Min. 1/4-inch DensDeck (Optional) SBS- modified bitumen ENRGY 3 or Multi -Max FA primed with FlintPrlme SA M-PG1 SBS-SA SA SBS-SA -180.0 roofcover Existing fully R-10 bonded BUR or modified bitumen Min. 1.5-inch FlintBoard ISO, ACFoarn 11, ENRGY 3 or Multi -Max FA3 OB500 Min. 1/4-inch DensDeck DuraGuard OB500 SBS-SA (Optional) SBS- SBS-SA roof cover I SA Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report 3520.03.04-RS for FL2533-RS Certificate of Authorization *9503 Prepared by: Robert Nleminen, PE Revision 5: 04/26/2011 -59166 Appendix 1, Page 37 of 40 1, _1110� r I I , " I cnrjr, �JTRINITYIERD TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A: BONDED INSULATION, BONDED ROOF COVER System Substrate (See Base Insulation Layer Top Insulation Layer Roof Cover No. Notes I & 11) MDP (psf) Type Attach Type Attach Base Ply Cap Existing fully Min. 1/4-Inch DensDeck R-11 bonded BUR or Min. 1.5-Inch ACFoam II, FlintBoard OBSOO primed with FlIntPrime SA OBSOO SBS-SA (Optional) SBS- SBS-SA -120.0 modified bitumen ISO or ENRGY 3 or SECUROCK Gypsum- SA roofcover Fiber Roof Board Existing fully Min. 1.0-Inch ISO 95+ GL, H-Shleld, R-12 bonded BUR or H-Shleld CG, ENRGY 3 or JM ISO 3 min. 1.3-inch ACFoam III, Min. 1.5- CR-20 Min. 1/4-inch DensDeck CR-20 SBS-SA (Optional) SBS- SBS-SA -105.0 modified bitumen Inch Multi -Max FA3 or Ultra -Max or DuraGuard SA roofcover min. 2.0-Inch ACFoam IV Existing fully Min. 1.0-inch ISO 95+ GL, H-Shleld, R-13 bonded BUR or H-Shleld CG, ENRGY 3 or IM ISO 3 min. 1.3-inch ACFoam III, Min. 1.5- CR-20 Min. 1/4-Inch SECUROCK CR-20 SBS-SA (Optional) SBS- SBS-SA -172.5 modified bitumen Inch Multi -Max FA3 or Ultra -Max or Gypsum -Fiber Roof Board SA roof cover min. 2.0-Inch ACFoam IV Existing fully Min. 1.0-inch ISO 95+ GL, H-Shleld, R-14 bonded BUR or H-Shield CG, ENRGY 3 or JM ISO 3 min. 1.3-inch ACFoam III, Min. 1.5- CR-20 Min. 1/4-Inch DensDeck CR-20 SBS-SA (Optional) SBS- SBS-SA -192.5 modified bitumen inch Multi -Max FA3 or Ultra -Max or primed with FlintPrIme SA SA roof cover min. 2.0-Inch ACFoam IV CONVENTION.L SYSTEMS: Min. 1/2-Inch Structodek Existing fully Min. 1.5-inch ACFoam 11, FlintBoard High Density Fiberboard, (Optional) BP - SBS-AA, R-15 bonded BUR or modified bitumen ISO, ENRGY 3, H-Shleld or Multi -Max HA Min. 3/4-Inch FescoBoard (homogeneous) or Min. HA BP -AA or SBS-AA AA, SBS-AA, SBS-TA or APP- SBS-TA or -105.0 roof cover FA3 1/2-inch DuraBoard TA APP-TA (homogeneous) Existing fully bonded BUR Min. 1.5-Inch ACFoam II, FlintBoard Min. 1/4-Inch SECUROCK Gypsum -Fiber Roof Board, BP -AA, SBS- (Optional) BP- SBS-AA, R-16 or modified bitumen ISO, ENRGY 3, H-Shleld or Multi -Max HA DensDeck,DensDeck HA AA, SBS-TA AA, SBS-AA, SBS-TA or APP- SBS-TA or -105.0 roof cover FA3 Prime or DensDeck or APP-TA TA APP-TA DuraGuard Existing fully (Optional) BP- R-17 bonded, smooth Min. 1.5-inch ACFoam II, FlIntBoard A-PD Min. 1/2-Inch Structodek A-PD BP -AA or AA, SBS-AA, SBS-AA, surface BUR or ISO, ENRGY 3 or H-Shleld 6-inch o.c. High Density Fiberboard 6-Inch o.c. SBS-AA SBS-TA or APP- SBS-TA or -52.5 modified bitumen TA APP-TA Existing fully bonded, smooth Min. 2-inch ACFoam II, FlintBoard ISO,' A-PD Min. 1/4-Inch SECUROCK A-PD BP -AA or SBS-AA, (Optional) BP - AA, SBS-AA SBS-AA, R-18 surface BUR or ENRGY 3 or H-Shleld 6-Inch o.c. Gypsum -Fiber Roof Board DensDeck 6-Inch o.c SBS-TA or SBS-TA or �Pp- SBS-TA or -52.5 modified bitumen or APP-TA TA APP-TA Existing fully (Optional) BP- R-19 bonded, mineral Min. 1.5-inch ACFoarn II, FlIntBoard A-PD I Min. 1/2-inch Structodek A-PD BP -AA or AA, SBS-AA, SBS-AA, surface BUR or ISO, ENRGY 3 or H-Shield 6-inch o.c. High Density Fiberboard 6-Inch o.c. SBS-AA SBS-TA or APP- SBS-TA or -172.5 modified bitumen I TA APP-TA Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report 3520.03.04-115 for FL2533-R5 Certificate of Authorization #9503 Revision 5: 04/26/2011 Prepared by, Robert Nfeminen, PE-59166 Appendix 1, Page 38 of 40 � r I& I 3 ." . 1116 1ERD JTRINITY1 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A: BONDED INSULATION, BONDED ROOF COVER System Substrate (See Base Insulation Layer Top Insulation Layer Roof Cover No. Notes I & 11) MDP (psf) Type Attach Type Attach Base Ply Cap R-20 Existing fully bonded, mineral Min. 2-Inch ACFoam II, FlintBoard ISO, A-PD Min. 1/4-Inch SECUROCK A-PD BP -AA or SBS-AA, (Optional) BP- AA, SBS-AA SBS-AA, surface BUR or ENRGY 3 or H-Shield 6-Inch o.c. Gypsum -Fiber Roof Board or DensDeck 6-Inch 0.c SBS-TA or SBS-TA or �Pp- SBS-TA or -172.5 modified bitumen APP-TA TA APP-TA Existing fully bonded BUR or Min. 1.5-Inch thick ACFoam II or Min. 1/4-Inch DensDeck or BP -AA or SBS-AA, (Optional) BP- AA, SBS-AA SBS-AA1 R-21 modified bitumen FlIntBoard ISO. M-PFIA SECUROCK Gypsum -Fiber M-PFIA SBS-TA or SBS-TA or �Pp- SBS-TA or -135.0 roof cover Roof Board APP-TA TA APP-TA Existing fully (Optional) BP- R-22 bonded BUR or Min. 1.5-Inch ACFoam II, FlintBoard M-OSFA Min. 1/2-Inch Structodek M-OSFA BP -AA or AA, SBS-AA, SBS-AA, modified bitumen ISO, ENRGY 3 or H-Shleld High Density Fiberboard SBS-AA SBS-TA or APP- SBS-TA or -127.5 roof cover TA APP-TA R-23 Existing fully bonded BUR or Min. 1.5-Inch ACFoam II, FlintBoard Min. 1/4-inch SECUROCK BP -AA or SBS-AA, (Optional) BP- AA, SBS-AA, SBS-AA, modified bitumen ISO, ENRGY 3 or H-Shleld M-OSFA Gypsum -Fiber Roof Board M-OSFA SBS-TA or SBS-TA or APP- SBS-TA or -157.5 roof cover or DensDeck APP-TA TA APP-TA Existing fully (Optional) BP- R-24 bonded BUR or Min. 1.5-Inch ACFoam 11, FlIntBoard M-PG1 Min. 1/2-Inch Structodek M-PG1 BP -AA or AA, SBS-AA, SBS-AA, modified bitumen ISO, ENRGY 3 or H-Shield High Density Fiberboard SBS-AA SBS-TA or APP- SBS-TA or -180.0 roof cover TA APP-TA R-2S Existing fully bonded BUR or Min. 1.5-Inch ACFoam II, FlintBoard Min. 1/4-Inch SECUROCK BP -AA or SBS-AA, (Optional) BP- AA, SBS-AA, SBS-AA, modified bitumen ISO, ENRGY 3 or H-Shleld M-PG1 Gypsum -Fiber Roof Board M-PG1 SBS-TA or SBS-TA or APP- SBS-TA or -180.0 roof cover or DensDeck APP-TA TA APP-TA Existing fully (Optional) BP- R-26 bonded BUR or Min. 1.5-Inch ACFoam II, FlintBoard OB500 Min. 1/2-Inch Structodek OB500 BP -AA or AA, SBS-AA, SBS-AA modified bitumen ISO, ENRGY 3 or H-Shleld High Density Fiberboard SBS-AA SBS-TA or APP- SBS-TA or 120.0 roof cover TA APP-TA R-27 Existing fully bonded BUR or Min. 1.5-Inch ACFoam II, FlintBoard Min. 1/4-inch SECUROCK Gypsum -Fiber Roof Board, BP -AA, SBS- (Optional) BP- AA, SBS-AA, SBS-AA, modified bitumen ISO, ENRGY 3 or H-Shleld OB500 DensDeck or DensDeck OB500 AA, SBS-TA SBS-TA or APP- SBS-TA or 120.0 roof cover Prime or APP-TA TA APP-TA Existing fully Min. 1.0-Inch ISO 95+ GL, H-Shleld, R-28 bonded BUR or bitumen H-Shfeld CG, ENRGY 3 or JM ISO 3 min. 1.3-Inch ACFoam III, Min. 1.5- CR-20 Min. 1/4-Inch DensDeck or CR-20 SBS-TA (Optional) SBS_ SBS-TA 180.0 modified roof cover Inch Multi -Max FA3 or Ultra -Max or DensDeck Prime TA min. 2.0-Inch ACFoam IV Existing fully Min. 1.0-Inch ISO 95+ GL, H-Shleld, Min. 1/2-inch Structodek High Density Fiberboard or (Optional) BP- R-29 bonded BUR or H-Shield CG, ENRGY 3 or IM ISO 3 min. 1.3-Inch ACFoam III, Min. 1.5- CR-20 DuraBoard CR-20 BP -AA or AA, SBS-AA SBS-AA, SBS-TA modified bitumen Inch Multi -Max FA3 or Ultra -Max or (homogeneous) or min. SBS-AA SBS-TA or XPP- or APP-TA -180.0 roof cover min. 2.0-Inch ACFoam IV 1.5-inch FescoBoard TA I I (laminated) I Exterior Research and Design, LLC. d/b/a TrinityjERD Evaluation Report 3520.03.04-R5 for FL2533-115 Certificate of Authorization #9503 Revision 5: 04/26/2011 Prepared by: Robert Nleminen, PE-59166 Appendix 1, Page 39 of 40 * P \J TRINITY 1 ERD TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A: BONDED INSULATION, BONDED ROOF COVER System Substrate (See Base Insulation Layer Top Insulation Layer Roof Cover MDP (psf) Type Attach Type Attach —Base Ply Cap No. Notes I & 11) Existing fully Min. 1.0-Inch ISO 95+ GL, H-Shield, (Optional) BP - R-30 bonded BUR or H-Shleld CG, ENRGY 3 or JM ISO 3 Min. 1.3-inch ACFoam III, Min. 1.5- CR-20 Min. '/4-Inch SECUROCK CR-20 BP -AA or AA, SBS-AA, SBS-AA, SBS-TA or -225.0 modified bitumen Inch Multi -Max FA3 or Ultra -Max or Gypsum -Fiber Roof Board SBS-AA SBS-TA or APP- APP-TA roof cover min. 2.0-inch ACFoam IV TA Existing fully Min. 1.0-Inch ISO 95+ GL, H-Shield, R-31 bonded BUR or H-Shleld CG, ENRGY 3 or JM ISO 3 min. 1.3-inch ACFoam III, Min. 1.5- CR-20 Min. 1/4-Inch SECUROCK CR-20 SBS-TA or (Optional) SBS- SBS-TA or -232.5 modified bitumen Inch Multi -Max FA3 or Ultra -Max or Gypsum -Fiber Roof Board APP-TA TA or APP-TA APP-TA roof cover min. 2.0-Inch ACFoam IV Existing fully Min. 1.0-inch ISO 95+ GL, H-Shleld, (Optional) BP - bonded BUR or H-Shleld CG, ENRGY 3 or JM ISO 3 BP -AA or AA, SBS-AA, SBS-AA, modified bitumen min. 1.3-inch ACFoam III, Min. 1.5- CR-20 Min. 1/4-inch DensDeck CR-20 SBS-AA SBS-TA or APP- SBS-TA or -240.0 roof cover Inch Multi -Max FA3 or Ultra -Max or TA APP-TA min. 2.0-Inch ACFoam IV TABLE 7B: RECOVER DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE F: NON -INSULATED, BONDED ROOF COVER System No. Substrate (See Notes I & 11)T Primer Roof Cover MDP (psf) Base Ply Cap COLD -APPLIED SYSTEMS: R-33 I Existing fully bo nded BUR over concrete deck (OP tional) ASTIVI D41 BP-CA1 (Optional) SBS-CA1 SBS-SA-1 I 187.5 I Exterior Research and Design, LLC. d/b/a TrInItyjERD Evaluation Report 3520.03.04-115 for FL2533-R5 Certificate of Authorization #9503 Revision 5: 04/26/2011 Prepared by: Robert Nleminen, PE-59166 Appendix 1, Page 40 of 40