HomeMy WebLinkAboutEngineeringRECEIVED 'MOM EXPRESS® FEB 2 0,77 ST. Lucie County, Permittina Order (Ref) #: 59501(43870-7846180556) Project tSiONS EW111JOMINIUM Contractor: CWS INC. 4000 N HIGHWAY AlA 11735 LANE PARK ROAD TAVARES, FL HUTCHINSON ISLAND / FORT PIERCE, FL Subject: Wind Load Design Pressure Calculations (Components & Cladding) Site Information Building Classification: enclosed Wind Speed (V It): 160 mph Exposure Category: d Roof Type: monoslope Roof Slope (0): 0.0 deg Mean Roof Height (h): 140.0 ft Min. Building Dimension (L): 85.0 ft Parapet >_ 3 feet? No General Calculation Directionality Factor (Kd): 1 Gust -Effect Factor (G): 0.85 Internal Pressure Coefficient(GCPf . )' ±0.18 Topographical Factor (K,t): 1.0 Velocity Pressure Exposure Coefficient ( nK): 1.52 Velocity Pressure (qh): 99.57 psf End Zone (a): 8.5 ft ASD Method: P = 0.6w Mark Qty Elev (ft) Size: W x H (in) Zone Shutter? Area (ft2) Kr (Kh) 9z;(9 h) GCp, IGCp_ Pressures (psf) mb (1) 140.0 113.0x77.0 4 No 60.4 1.52 99.57 0.80 1-0.83 +58.4/-60.6 mb (1) 140.0 33.0 x 77.0 4 No 17.6 1.52 99.57 0.90 -0.90 +64.5 /-64.5 Ir (1) 140.0 202.0 x 92.0 5 No 129.1 1.52 99.57 0.73 -1.34 +54.1 / -90.6 Ir (1) 140.0 107.0x92.0 5 No 68.4 1.52 99.57 0.79 -1.49 +57.7/-100.0 Ir (1) 140.0 59.0 x 65.0 4 No 26.6 1.52 99.57 0.87 -0.88 +62.9 /-63.6 gp (1) 140.0 39.0 x 94.0 4 No 25.5 1.52 99.57 0.88 -0.89 +63.2 / -63.8 gp (i) 140.0 39.0 x 94.0 4 No 25.5 1.52 99.57 0.88 -0.89 +63.2 / -63.8 Id (1) 140.0 100.0 x 59.0 5 No 41.0 1.52 99.57 0.83 -1.62 +60.5 / -107.6 Id (1) F140.0 60.0 x 92.0 5 No 38.3 1.52 99.57 0.84 -1.64 +60.9 / -108.6 gb (1) 1 140.0 84.0 x 92.0 4 No 53.7 1.52 99.57 0.81 -0.84 +59.0 / -61.0 NOTES: Design is Inaccordance with ASCE 7-10 (ASD method) and the Florida Building Code Sixth Edition (2017). Results are not valid for use unless approved via original signature and raised engineer seal of a PE from Engineering Express. Results are based on contractor -supplied data and shall be field verified by others prior to use. Selection & installation of products shall be approved using these dimensions and pressures as verified by others. Note: For openings to be properly rated in Zone 4, no part of the opening shall be within 8.5 feet of any building m?n 0; This engineer has not field visited this location and if this cannot be clearly Identified by others, the opening shallbe re- evaluated prior to installation of any fenestration. All other information provided above including mean roof height,* building minimum dimensions, opening sizes, & other sup in a e;f prroovve .�by oo hers. For definitions of tfje above terms, visit EngineeringExpress.com/WikiAli"®R .� Jal`�QPIN iMiih aised/Staml rSepi M P g97F328,- SiP1 9885•' �� SSIONF \.. 160SW1271-PAY E;tSUI�T•'E1 0�R(p)(3 R- 59501(43870-7846180556) PHO 95 S AutoPrint ENGINEERINGEXPRESS.COM PAGE 1 OF 1