HomeMy WebLinkAboutSUBMITTED PAPERSDATE: �3 - �/ FEES 1;'., RECEIPT #: i Permit #:
LUC
Planning & Development Services Department
® Building & Code Regulation Division SCAvjq�o
e 2300 Virginia Avenue
Ft Pierce, FL 34982-5652 St C
Tel.772-4624553 UCie Count
APPLICATION FOR ROOF PERMIT Y
SEE REVERSE RE FO INSTRUCTIONS
1. Location/Site Address: Col (� 3 Ocr1 ce Kea n pir✓ c e r
2. Parcel ID Number: 1300 l l 006 l 0000
3.
4.
6.
Office Use --
Only
Section
Townshi
Ran a
Ma Page
ZoningLand
Use
itials
3�
Via,- o i olcd Tco� . re,�/ace �.eel
Description of Project or Work Activity: �" aHnl 3o„Y be alas s k,os It
Total Roof Area (square feet): 9000 5. Roof Pitch: a12
Type of Roof: [ Fiberglass Shingle [ J Concrete Roof Tile [ J Wood Shake / Shingle
/ [ J Tar & Gravel [ J Modified Bitumen [ J Other
[✓J Product Approval required for all types of Roofing Material (2 Sets)
[ J All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product
Approval attached
** Roof Mitigation per F.S. 553.844 will be required.
7. Owner Information . 8. Contractor Information
Name: �Rr I Pleger FL Reg/Cert #: C C C 1325 "7 7-7
Address: (0-7 0 QyI Ce County Cert #: dQ V�
City: ej PPerc e State: L Business Name: Tan 4- 5� 1 �S
Zip: I Phone: S a3 Cell Phone: (77 913 P J 546
a •
9. Value of Construction: $ 7.3oo, 6a??�3 2397
**Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval.
CONTRACTOR/OW NEWS AFFIDAVIT: I certify that allof the info ation contained in this application is correct and that all work will be
nn , done in comp ance wi applicable laws regulating construction and zoning.
err Caudal
PRINT Q[JALIFIERS/O NAME I OF QUALWIEER/OWNER
STATE OF FLOREDA, COUNTY OF _ —^ ' /
-//
ACKNOWLEDGED BEFORE ME THIS � DAY OF 20� , BY l�f r 1` Cay� I
O Is PERSONALLY KNOWN TONE OR HAS ODUC
DAWN MILONE
�IY ('gMMISSION # DD 852587
OF NOTARY TYPE OR PRINT NAME OF NOTARY =': ..Real EXPIRES: March 22, 2013
' " Public Und'1*4
•��gf tip, Bonded ThN Notary
COMMISSION NUMBER
NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE
FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
Revised 4)26/2010
� INSTRUCTIONS
Please complete all information in the space provided. All information must be printed (use black or blue ink
only) °or typed. This roof permit application is to be used only for those activities that are not otherwise included
under a primary building permit. This application may not be used for any activity that includes structural
alteration. Building activities involving structural alteration, in addition to the roof work, must be permitted
through the regular building permit review process. The information to be provided with this application
includes:
1. Location/Site Address
2. Parcel ID Number
3. Description of Project or Work Activity
4. Total Roof Area
5. Type of Roof
6. Owner Information
7. Contractor Information
8. Value of Construction
Indicate the street address or, general location of the
property where the building activity is taking place.
Indicate the tax identification number of the property where
the building activity is taking place.
Completely describe the building activity to take place.
Please indicate if tear -off or shingle over shingle etc.
Indicate total roof area to be affected by this permit. Also
indicate the pitch of the roof, expressed as a standard ratio
of run rise.
Indicate the type of roof being. repaired or resurfaced.
Indicate 'the name and address of the owner of the property
on which building activity is taking place.
Indicate the State of Florida registration number (if
applicable), St. Lucie County contractor license number and
the name of the business doing the work.
Indicate the total value of the work to take place. Total cost
of construction includes all material and labor costs
associated with the building/construction activity.
Construction value is used to determine the permit fee. St.
Lucie County reserves the right to question and/or modify
the indicated value of construction if it is demonstrated that
the submitted figures are not consistent. with similar types
of construction.
This application can be submitted to St. Lucie County Building and Zoning, 2300 Virginia Avenue, Fort Pierce,
FL 34982. All permit applications must be filled out completely before submission. No applications will W
acre ted'for rocessiQgafter-430 PAL For assistance in completing this application, please call (772)
P P, i�" . , . ,.
462-1553;, during: regular- office, hours (8:00 ;AM - 5:00 PM), Monday through Friday.
Upon issuance of this=permit;;required inspections can be scheduled by calling (772) 462-1261.
St Lucie County Roof Permit Application rev. 3/1/2009
JOSEPH E. SMITH, CLERK OF THE CIRCUIT COURT.— SAINT LUCIE COUNTY
FILE # 3615067 OR 13OC' 312 PAGE 2305, Recorded 08/03/2011-`yt0:28 AM
NOTICE OF COMMENCEMENT
711e undersigned hereby given -tics that improvement will made to certain real property, and in accordance with Chapter 713,
Florida Statues the following information is provided in the Notice of Commencement
I. DEscRomoN of PROPERTY (Legal description and street address, if available) TAX Fouo Nusmt.H:
2. GYNERAL qqF�S ON Ol DID: R VEaff.Nr:
mar _ 0l'1' cld %�� t ftpltl t wig _XfY, Qj 1 5471b -0,nq 3D�,�ry)css
3. OWNER INFORMATION: aNeme
0.lrtrraninPropow
d Noma ud add noffw zhWeWlelatder (1[ativr rho Owns) p/
d. ^C70*'SNAM4 AHD IHON! el Nis. C�j Z7V7
S. SURETY'S NAME, ADDRESS AND PHONE NUMBER AND BOND AMOUNI.
6. LENDER'S NAIL ADDRESS AND PEONS Kum=:
7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by
Section 713.13 (I) (a) 7., Florida Statutes:
NAME. ADDRESS AND PHONE NUMBER:
B. In addition to himself or hersel[ Owner designates the following to receive a copy of the Lienor's Notice as provided in Section
713.13 (1) (b), Florida Statutes:
NAME. ADDRESS AND PHONE NUamER:
9. Expiration date of notice of commencement (the expiration data is 1 year from the data of recording unless a different date is
specified):— 2f11
State of Florida
Countyof S-t. Lucie
The fo oin ittg ern was aclinowledged before me this, day of ^y am 20_ I
By I nn L_ as Uwe _ u—r
(name of person) (type ofauthorisy,...e.g. officer, trustee, attorney in fact)
For
(name of party on be calf of whom instrument was executed) r LpL. P4W -Jr08-3$-4--Xr
a
Pe ofidentification: P-4L 4a(o-oj;k.Lq.5gr
BETTY:Stal,,F
r ; h�Jgtery Public -
loridaMj Comm. Exp, 2014Commission 009E(Sigrenue ofNotary Pu is1;�%B".,., _Bonded Through Nary Asan,Under Pen o a< ongoing and that the facts in it are true to the best of my knowledge and
belief (Section 92.M, Florida Statutes).
Signsture(e) Oan�11,er(s)' Autborhed OIIIeer/DireetorI Parmer/Mmajer who signed above. By
Rar,01-09-01 (S.Recordaa)
STATE Of FLORIDA
ST. LUCIE COUNTY
Im
TR
OR
By
9_4
MIAMI.I7�ADE
® MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION` Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315.2599
NOTICE OF ACCEPTANCE (NOA) www.ininniidade.gov/buildine/
Owens Corning Roofing and Asphalt, LLC
One Owens Corning Parkwa
Toledo, OH 43659 y
SCOPE: COPY
This NOA is being issued under the applicable. rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control
Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction
(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right
to have this product or material tested for quality assurance purposes. If this product or material fails to
perform in the Accepted manner, the manufacturer will incur the expense of such testing and the AHJ may
immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC
reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control
Section that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida -Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: OakridgeO Shingle
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been fled and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other -purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal- of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall
be done in its entirety.
INSPECTION: A copy of this entire NOA shall' be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Offioial.
This revises NOA# 10-1015.01 and consists of pages i through 4.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 11-0411.03
Expiration Date: 02/03/16
Approval Date: 06/16/11
Page 1 of 4
ROOFING ASSEMBLY APPROVAL
Category:
Roofing
Sub=Cateaorv.
Asphalt Shingles
Materials
Laminate
Deck Type:
Wood
SCOPE
This approves a roofing system using Owens Corning Oakridge® asphalt shingles manufactured by Owens
Corning as described in Section 2 of his Notice of Acceptance.
PRODUCT DESCRIPTION
Product Dimensions Test Product'Description
Specifications
Oakridge® 13 '/4" x 39 3/8" TAS 110 A heavy weight, fiberglass reinforced
Manufacturing laminate asphalt shingle with continuous
Locations #1, 2, 3, 4 bead of sealant.
Oakridge® 13 'A" x 39 a/8" TAS 110 A heavy weight, fiberglass reinforced
Manufacturing Iaminate asphalt shingle with dashed bead of
Location #1, 3, 4 sealant.
MANUFACTURING LOCATION
1. Memphis, TN
2. Irving, TX
3. Savannah, GA
4. Jacksonville, FL
EVIDENCE SUBMITTED
Test Agency
Test Identifier
Test Name/Report
Date
PRI Construction Materials Technologies
OCF-153-02-01
TAS 100
09/22/10
PRI Construction Materials Technologies
OCF-152-02-01
TAS 100
09/21/10
PRI Construction Materials Technologies
OCF-158-02-01
TAS 100
I 1/10/10
PRI Construction Materials Technologies.
OCF-151-02-01
TAS 100
09/27/10
PRI Construction Materials Technologies
OCF-150-02-01
TAS 100
09/21/10
PRI Construction Materials Technologies
OCF-165-02-01
TAS 100
01/07/11
PRI Construction Materials Technologies
OCF-170-02-01
TAS 100
06/06/11
Underwriters Laboratories
09NK14530
ASTM D 3462
12/31/09
Underwriters Laboratories
R2453
ASTM D 3462
10/11/10
Underwriters Laboratories
R2453
ASTM D 3462
11/03/10
Underwriters Laboratories
R2453
ASTM D 3462
10/11/10
Underwriters Laboratories
R2453
ASTM D 3462
10/11/10
Underwriters Laboratories
R2453
ASTM E 108
01/13/11
Underwriters Laboratories
R2453
ASTM E 108
10/11/10
Underwriters Laboratories
R2453
ASTM E 108
11/03/10
NOA No.:11-0411.03
MIAMI DME COUNTY
Expiration Date: 02/03/16
Approval Date: 06/16/11
Page 2 of 4
Underwriters Laboratories
R2453
ASTM E 108
10/11/10
Underwriters Laboratories
R2453
ASTM E 108
10/11/10
Underwriters Laboratories
09NK14530
TAS 107 (ASTM D 3161)
12/31/09
Underwriters Laboratories
OINK44201
TAS 107 (ASTM D 3161)
09/09/02
Underwriters Laboratories
IONK13947
TAS 107 (ASTM D 3161)
11/12/10
Underwriters Laboratories
R2453
TAS107 (ASTM D 3161)
10/11/10
Underwriters Laboratories
03NK04954
TAS 107 (ASTM D 3,161)
03/07/03
Underwriters Laboratories
IONK13947
TAS 107 (ASTM D 3161)
01/28/11
Underwriters Laboratories
11CA15662
TAS 107 (ASTM D-3161)
05/27/11
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory
for fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall. have a quality assurance audit in accordance with the Florida Building
Code and Rule 9B-72 of the Florida Administrative Code.
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail'A', attached.
5. Nailing shall be in compliance with Detail'B', attached.
LABELING
1. Shingles shall be labeled with the Miami -Dade Seal as seen below, or the wording "Miami -Dade County
Product Control Approved".
MIAMI-DADE COUNTY
BUILDING PERMIT REQUIREMENTS
1. Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code in order to properly
evaluate the installation of this system.
NOA No.: 11-0411.03
Expiration Date: 02/03/16
Approval Date: 06/16/11
Page 3 of 4
�--- 19-1/2"
t
I
l
l
I I
I I
I i
I 1
I
I
1
FIR:
DETAIL A
DETAIL B
3/8"
211
OWENS CORNING OAKRIDGE
WITH CONTINUOUS OR DASHED SEALANT
END OF THiS ACCEPTANCE
5 5/8" EXPOSURE
NOA No,: 11-0411.03
MIAMbDADE COgt TY Expiration Date: 02/03/16
Approval Date: 06/16/11
Page 4 of 4
f
COUNTY , ;�
BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT {BNC)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA
Polyglass USA Inc.
150 Lyon Drive
Fernley, NV 89408
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
www.miamidade.gov/building/
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control
Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction
(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right
to have this product or material tested for quality assurance purposes. If this product or material fails to
perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may
immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC
reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control
Section that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Polystick NITS, IR-Xe, TU, TU Plus and TU P
LABELING: Each unit shall.bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall
be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This revises NOA#09-0806.07 and consists of pages 1 through 6.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 11-0203.02
Expiration Date: 09/13/11
Mi; oAnE eouNnr Approval Date: 04/21/11
Page I of 6
f
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub -Category- Underlayment
Material: SBS , APP Self -Adhering Modified Bitumen
PRODUCTS DESCRIPTION:
Test
Product
Product
Dimensions
Specification
Description
Polystick MTS
Roll:
TAS 103
A homogeneous, rubberized asphalt
underlayment
65'8" x 3'3 '/g"
waterproofing membrane, glass fiber
60 mils thick
reinforced with polyolefinic film on the upper
Manufacturing
surface for use as an underlayment for metal
Location #2
roofing, roof tile, slate tiles and shingle
underlayment.
Polystick IR-Xe
Roll:
TAS 103 and
A fine granular/sand top surface self-
underlayment
.6558" x 3'33/8"
ASTM D 1970
adhering, APP polymer modified, fiberglass
80 mils thick
-
reinforced, bituminous sheet material for use
and
as an underlayment in sloped roof assemblies.
Manufacturing
67" x 36"
Designed as an ice & rain shield and as a flat
Location #1 & #2
80 mils thick
roof tile underlayment.
Polystick TU
Roll:
TAS 103 and
A heavy granuled surface self adhering, APP
underlayment
32' 10" x 333-3/8"
ASTM D 1970
polymer modified, fiberglass or polyester
100 mils thick
reinforced, bituminous sheet material for use
Manufacturing
as an underlayment in sloped roof assemblies.
Location #1 & #2
Designed as a a roof tile underlayment.
Polystick TU Plus
Roll:
TAS 103 and
A non -wicking fabric surfaced, self -adhering,
underlayment
65'8" x 3533/8"
ASTM D 1970
APP polymer modified, fiberglass reinforced
(Facer of Membrane
80 mils thick
with a high strength polyester fabric,
Labeled in Orange
bituminous sheet material for use an an
or Black Ink)
underlayment in sloped roof assemblies.
Manufacturing
Designed as a metal roofing and roof tile
Location #1 & #2
underlayment.
Polystick TU P Roll:
underlayment 32' 10" x 3'3-3/8"
Manufacturing 130 mils thick
Location #2
MANUFACTURING PLANTS:
TAS 103 and A rubberized asphalt waterproofing .
ASTM D 1970 membrane, glass-fiber/polyester reinforced,
with a granular surface designed for use as a
tile roof underlayment.
1. 555 Oakridge Road, Hazelton, PA
2. 621 Sniveley Avenue, Winter Haven, FL
NOA No.: 11-0203.02
Expiration Date: 09/13/11
Approval Date: 04/21/11
Page 2. of 6
)EVIDENCE SUBMITTED:
Test Agency
Test Identifier
Test Name/Reyort
Date
Exterior Research & Design, LLC
# 11756.04.01-1
TAS 103
04/27/01
#11756.08.01-1
ASTM D 1970
08/14/01
#02202.08.05
TAS 103
08/29/05
Trinity I ERD
#P5110.08.07
TAS 103
08/29/07
P10870.09.08-R1
TAS 103
12/04/08
P10870.04.09
TAS 103/ASTM D4798 & G 15 5
04/13/09
PRI Asphalt Technologies
PRIOI 111
ASTM D 4977
04/08/02
PUSA-005-02-01
ASTM D 4977
01/31/02
PUSA-018-02-01
ASTM D 2523
07/14/03
PUSA-035-02-01
TAS 103
09/29/06
PUSA-033-02-01
ASTM D 1970
01/12/06
PUSA-055-02-02
TAS 103
12/10/07
PUSA-083-02-01
TAS 103
06/30/08
PUSA-089-02-01
TAS 103/ASTM D4798 & G155
07/06/09
Momentum Technologies, Inc.
JX20147A
TAS 103/ASTM D4798 & G155
04/01/08
RX14E8A
TAS 103/ASTM D4798 & G155
11/09/09
DX23D8B
TAS 103/ASTM D4798 & G155
02/18/10
DX23D8A
TAS 103/ASTM D4798 & G155
02/18/10
INSTALLATION PROCEDURES:
Deck Type 1: Wood, non -insulated
Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head
lap. (for base sheet only)
Membrane: Polystick membranes self -adhered.
Surfacing: None
1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking
panels, and sweep the deck thoroughly to remove any dust and debris prior to application.
2. Place the underlayment over metal drip edge in accordance with RAS 111.
3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum
contact. Remove the release film as the membrane is applied. . All side laps shall be a minimum
of 3-'/z" and end laps shall be a minimum of 6." Roll the membrane into place after removing the
release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back
nailed in accordance with applicable building code.
4. When applying the membrane in the valley, start at the low point and work to the high point,
rolling the membrane from the center outward in both directions.
5. For ridge applications, center the membrane and roll from the center outward in both directions.
6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving
special attention to lap areas.
7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current
Product Control Notice of Acceptance.
8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing
tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second
layer of Polystick shall be applied over the underlayment.
NOA No.: 11-0203.02
• Expiration Date: 09/13/I1
QM1 DADS COUNTY Approval Date: 04/21/11
Page 3 of 6
GENERAL LIMITATIONS:
11.
2.
3.
4.
5.
6.
7.
8.
10.
Fire classification is not part of this acceptance.
Polystick MTS and TU Plus may be used in asphaltic shingles, wood shakes and shingles, non-structural
metal roofing, roof tile systems and quarry slate roof assemblies. IR-Xe, TU, and TU P may be used in all the
previous assemblies listed except metal roofing.
Deck requirements shall be in compliance with applicable building code.
Polystick membranes shall be applied to a smooth, clean and dry surface. The deck shall be free of
irregularities.
Polystick membranes shall not be adhered directly over a pre-existing roof membrane as a recover. system.
The following membranes manufactured in Winter Haven, FL Plant; Polystick MTS, IR-Xe, TU, TU P and
TU Plus shall not be left exposed as a temporary roof for longer than 180 days after application. Polystick TU
Plus, manufactured in Hazelton, PA Plant shall not be left exposed as a temporary roof for longer than 180
days after application. Polystick IR-Xe and TU fanufactured in Hazelton, PA Plant shall not be left
exposed as a temporary roof for longer than 30 days after application. Polyglass reserves the right to revise or
alter product exposure times; not to exceed the preceeding maximum time limitations.
All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 913-72 of the Florida Administrative Code.
In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile
manufacturer's Notice of Acceptance. Polystick TU and TU Plus may be used in both adhesive set and
mechanically fastened roof tile applications. Polystick IR-Xe is limited to mechanically fastened roof tile
applications. Polystick MTS is limited to mechanically fastened with battens roof tile applications. Polystick
TU P may be used in both adhesive set and mechanically fastened roof tile applications with the exception of
mortar set tile applications.
The maximum roof slope for use as roof tile underlayment for (direct -to -deck) the assemblies shall be as
follows: (See Table Below)
Tile Profile
Polystick MTS
Polystick IR-Xe
Polystick TU, TU
Plus TU P
Flat.Tile
Prohibited without battens
5:12
No limitation
Profiled Tile
Prohibited without battens
Prohibited
No limitation'
The above slope limitations can be exceeded only by using battens and counter battens in accordance. with the
Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. Polystick
MTS shall not be used in direct -to -deck applications. Battens are required for both loading and
installation of tiles at all times.
Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of
tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure for all
underlayments except Polystick MTS which shall be loaded onto battens.
MIAMI•DADE COUNTY
NOA No.: 11-0203.02
Expiration Date: 09/13/11
Approval Date: 04/21/11
Page 4 of 6
o
`J 1
GENERAL LIMITATIONS: (CONTINUED)
11. Refer to prepared roofing system Product Control Noticed Acceptance for listed approval of this
product with specific prepared roofing products. Polystick NITS, IR-Xe, TU, TU Plus and TU P
may be used with any approved roof covering Notice of Acceptance listing Polystick NITS, IR-Xe,
TU, TU Plus and TU P as a component part of an assembly in the Notice of Acceptance. If
Polystick NITS, IR-Xe, TU, TU Plus and TU P is not listed, a request may be made to the
Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for
approval provided that appropriate documentation is provided to detail compatibility of the
products, wind uplift resistance, and fire testing results.
LABELING:
1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's
name or logo, city and state of manufacturing facility and the following statement: "Miami -Dade
County Product Control Approved" or the Miami -Dade County Product Control Seal as shown
below.
QM1•D DDE COUNTY
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly
evaluate the installation of this materials.
POLYGLASs GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES:
1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks.
Installers are cautioned to refer to applicable local building codes prior to direct deck installation
to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the
corresponding products.
2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edge seam as
per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a
minimum 1" metal disk as required in Dade County or simplex type nail as otherwise allowable in
other regions, at a minimum rate of 12" o.c. Polystick TU Plus should be back nailed in designated
area marked "nail area, area para clavar" on the face of membrane, with the above stated nails
and/or disks. The head lap membrane is to cover the area being back -nailed. (Please refer to
applicable local building codes prior to installation.)
3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact.
4. All fabric over fabric; and granule'over granule end laps, shall have a 6" wide, uniform layer of
Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB
Flashing Cement, Polyglass PG500 MB Flashing Cement, Mule -Hide 241 Premium Modified
Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide
421 Mod Bit Flashing Adhesive Trowel Grade mastic, applied in between the application of the
lap. The use of mastic between the laps does not apply to Polystick MTS.
NOA No.: 11-0203.02
Expiration Date: 09/13/11
MIAMI•DADHcoUN YY Approval Date: 04/21/11
Page 5 of 6
r-.
5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the
Polyglass Tile Loading Guidelines. See General Limitations #9 and #10.
6. Battens and/or Counter -battens, as required by the the manufacturers NOA's, must be used on all
projects for pitch/slopes of T712" or greater. It is suggested that on pitch/slopes in excess of 6
'/4"/12", precautions should be taken, such as the use of battens to prevent rile sliding during the
loading process.
7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight
(48) Hours.
8. Polystick membranes may not be used in any exposed application such as crickets, exposed
valleys, or exposed roof to wall details.
9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium
Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing -Cement, Polyglass
P0500 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251
Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive
Trowel Grade mastic to the area in need of repair, followed by a patch of the Polystick material of
like kind should be set and hand rolled in place over the area needing such repair. Patching
membrane shall be a minimum. of 6 inches in either direction. The repair should be installed in
such a way so that water will run parallel to or over the top of all laps of the patch.
10.. All self -adhered membranes must be rolled to ensure full contact with approved substrates.
Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane.
Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be
used where slope prohibits rolling.
11. All approved substrates should be dry, clean and properly prepared, before any application of
Polystick membranes commences. An approved substrate technical bulletin can be furnished upon
request. It is recommended to refer to applicable building codes prior to installation to verify
acceptable substrates.
12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes and
PolyProtector UDL can be furnished upon request by our Technical Services Department by
calling 1 (800) 894-4563.
13. Polyglass offers a 10 year Limited Material Warranty on all properly installed Polystick self -
adhered underlayments. Warranty must be requested and registered by Polyglass to be in force.
14. Questions in regards to the application of Polyglass products should be directed to our Technical
Services Department at 1 (800) 894-4563.
15. Polyglass recommends thatapplicators follow good roofing practices and applicable procedures as
outlined by the National Roofing Contractors Association (NRCA).
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF
SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS
REQUIREMENTS AND RECOMMENDATIONS.
END OF THIS ACCEPTANCE
NOA No.: 11-0203.02
Expiration Date: 09/13/11
MIAMI-DADECOUNTY Approval Date: 04/21/11