Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Project infor
Submittal Prepared For: Date: March 17, 2020 Amazon Customer P.O. Number. Customer Project Number: Sold To: Job Number: Job Name: Amazon MEP Structural Design Amazon DVB1 7440 Commercial Circle FORT PIERCE, FL 34951 Trane U.S. Inc. is pleased to provide the enclosed submittal for your review and Product Summary r Qty Product 1 Air -Cooled Scroll 1 Performance Climate Changer (CSAA) Jose Perez Trane U.S. Inc. 2884 Corporate Way Miramar, FL 33025 The attached information describes the equipment we propose to fumish for this project, and is submitted for your approval. Product performance and submittal data is valid fora period of 6 months from the date ofsubrhittalgeneration) If six months ormore has elapsed between submittal generation and equipment release, the product performance and submittal data will heed to be verified. It is the customer's responsibility to obtain such verification. ti II J:IJOBS1441175353131Amazon DVB1 submittaLdoc ' \ ! Table Of Contents < � ProductSummary ........................................................................................... r.~~~~~~.~~. Air-Co��d�cm�U(b�olA1) °. � TagData ................................................................................................................ !^^^.^.^~~. ProductData .......................................................................................................... ..................... PerformanceData ...................................... ........................................................... ..................... ProductData 5Opump.................................................................. ..................... Mechanical Specifications---~^^^^~~~~~~~~^`~—'—`----------------- UnitDimenoions—.......—,.'_._-------------------.'------- VVeight,Qoamnna&Rigging Diagram ......................................................................................... Accessory........................~^^......~^,~^...^...,`...'```...`....................._............................ FleldVViring---.......`...`—.—`,.`.,---------------..................... Performance Climate Changer VCSAA)(Item B1) | ~n'~~~~~~`~`^`~'—`-------------------------.^^^^^~^~~ Product Data ........................................................................................................... ..................... �Performance Data .................................................................................................. -----..' ��echanioa|Spedfioo1ono.-------.--.--..--.........`--'i..................... As -Built .-----------..—..—..................,.—_---.��------' Fan Curve .............................................................................................................. —...~.,. Accessory ................................................................................................................................... � FieldWiring ............................................................................................................ 1..................... < PhAd Installed Options ^PartfOmMmrNumber Summary / Performance Climate Changer (CSAA)... --------------------............� � � � ' � | � / 1 .,'26 .,'20 ...27 --5U --34 --43 --45 --53 .-54 11 Structural Desl"i.,jiiazon DVB1 - �) 1) Item Ta s Q Descri tion Model Number 1 Al ICGAM-130p um 1 20-130 Ton Air -Cooled CGAM) CGAM130F2**2AXB2AIBlAlAXXAlDlA4XXX8BlB1 A3A1D1X-L-X I I Product Data - Air -Cooled Scroll Item: Al Qty: 1 Tag(s): CGAM-130pump Air -Cooled Scroll Packaged Chiller Startup Included - Trane Service must start equipment for warranty to be 130 nominal tons 60 hertz 460 volt 3 phases PHR High efficiency/performance Full factory refrigerant charge (HFC-410A) With factory installed freeze protection Refrigerant isolation valves (disch valve) afety standard ASHRAE 90.1 all versions p to 2016 AHRI certified Factory installed flow switc - set point 60 cm/sec o 18C) Grooved pipe connection Factory insulation 1.25" - high humidity/low evaporator temperature Performance based on water High ambient (up to 125F/up to 52C) Lanced aluminum fins Across the line starter/direct on line Single point connection main line unit power -ancillary items require other power Circuit breaker -high fault rated control panel Enclosure type UL 1995 rated for outdoor applications BACnet interface Dual high head pump Pump flow ctrl by var speed drive With buffer storage tank High A short circuit rating Elastomeric isolators With water strainer factory installed Super quiet Architectural louvered panels 2nd-5th year compressor parts list year labor warranty Performance Data - Air -Cooled Scroll Tags CGAM-130 um Refrigeration capacity tons 126.06 Total chiller power k 146.77 Cooling efficiency EER BtuAN-h 10.306 NPLV.IP (EER BtuAN-h 16.553 IPLV.IP (EER Btu/W-h 16.554 Sound power level (dBA) 95 Sound pressurelevel (dBA) 67 Refrigerant R410A Refrigerant charge circuit 1(lb) 112.0 Refrigerant charge circuit 2(lb) 112.0 Oil charge circuit 1 al 5.81 Oil charge circuit 2 al 5.81 Entering fluid eva F 53.98 Leavin fluid eva F 44.00 Flow eva m 301.81 FLD = Others KYA )XIIIl rated cond temp circuit 1 F 123.54 rated cond temp circuit 2 F 123.54 pressor power input (M) 134.35 - compressor 1A A 33.00 - compressor 1A A 215.00 - compressor 1 B A 33.00 ) - compressor 1 B A 215.00 - compressor 1 C A 41.90 - compressor 1 C A 260.00 - compressor 2A A 41.90 - compressor 2A A 260.00 - compressor 2B A 33.00 - compressor 26 A 215.00 - compressor 2C A 33.00 - compressor 2C A 215.00 airflow cfm 91332 bar of fans 10 jower M 12.22 fan FLA A 33.00 ik water ru rLu = Others Amazon MEP Structural Desiwazon DVB1 It I March 17 2020 Job Information Ton Air -Cooled i 7/PW20-130 Tag Model Number CGAM-130pump CGAM 130 Quantity 1 (t;� TOPSS version number 233 • 39 < Unit nominal tonnage 130 tons Unit type High efficiency iy�• General Information ' Sound attenuator package Super quiet IPLV.IP 16.55 EER (Btu/W-h) Refrigerant R410A NPLV.IP 16.55 EER (BtwW-h) Refrigeration capacity 126.1 tons Sound power level 95 dBA Full load refrigeration efficiency 10.31 EER (Btu/W-h) Sound pressure level 67 dBA Note: • At 30 feet in free field. Evaporator Information Evaporator application Sid cooling ,. Fouling factor 6.000100 hr-sq ft-deg F/ Btu Entering temperature 53.98 F Saturated temperatureckt 1 3I .6 F Leaving temperature 44.00 F Saturated temperature-ckt 2 37.6 F Fluid flow rate 301.E gpm Minimum flow rate 146.9 gpm Pressure drop 14.8 It H2O Pressure drop at min flow rate 5ii99 It H2O Total PD evap+strainer 20.9 ft H2O Flow switch set point 1 Flow switch set point 60 cm/s( c Evap fluid type Water i Freeze protection (factory inst) With freeze protection Evap fluid freeze point 32.00-F Condenser Information Unit application High ambient Total fan FLA i 39.00 A Ambient air temperature 95.0 F Total airflow 91 332 cfm Elevation 0.000 ft Fin material Lanced aluminum Number of fans 10.00 Each Saturated temperature -ckt 1 0 1.23.5 F Fan power 12.22 kW Saturated tem erature-ckt 2 123.5 F t Compressor Information Number of compressors 6 RLA. LRA Number of circuits 2 CompressorA 1 33.00A 215.00A Refrigeration capacity steps 6 Compressor B. 33.00 A 215.00 A Compressor power input 134.4 kW Compressor C 41.90 A 260.00 A Compressor D 41.911 0 A 260.00 A Compressor E i 33.00 A 215.00 A Compressor F 33.00 A 215.00 A Electrical Information Unit voltage 460. volt 3 phases Iv1CA MOP Unit hertz 60. hertz Single point power 285 A 300 A Short circuit High Incoming power line connection Single point Short circuit current rating 65000 A Starter type Across the line Total power input 146.8 kW Note: Unit power includes: compressors, condenserfans, and control kW 3/17/2020 TOPSS version number 233 i Data aeoeration data 117/ 020 Paae 1 of 2 FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 5 of 54 Others Amazon MEP Structural Des :._�nazon DVB1 ^-) nn�.,.r. 17 Iran IonAir- oo e Job Information TRAME` ! Tag CGAM-130pump Model Number CGAM 130 Quantity 1 TOPSS version number 233 - Unit nominal tonnage 130 tons .f Unit type High efficiency Certified in accordance with the AHRI Air -Cooled Water -Chilling Packages Certification Program which,is based on AHRI Standard 5501590 (I-P). Certified units may be found in the AHRI directory at wmw.ahridirectory.org. i a Pump Package Information { Pump type Dual high head Pump size 1 15.196 hp Avail head pressure at water 77.0 ft H2O Pump nominal current il 21.00 A connection Total PD pump+evap+strainer 26.8 fit H2O Expansion tank volume 6.30 gal Buffer tank With buffer storage tank Pump Bow control 1%ar speed drive Buffer tank volume 201.00 gal Physicallnformation Length 202in Water connection (inlet) 41000in Width 89 in Refrigerant charge circuit 1 112.0 lb Height 92 in Refrigerant charge circuit 2 1�12.0 lb Operating weight 116231b Oil charge circuit 1 5181 961 Shipping weight 9722lb Oil charge circuit 2 I &81 gal Note: This information includes the pump and buffer tank. Information for LEED Projects ASHRAE 90.1/CSA compliance ASHRAE allto2016 IPLV 16.55 EER (BtulW-h) Refrigerant charge circuit 1 112.0 lb Rated refrigeration capacity 126.1 tons (AHRI) Refrigerant charge circuit 2 112.0 lb Rated cooling efficiency 1 10.31 EER (Btu/W-h) Note: This product meets the minimum efficiency requirements of ASHRAE Standard 90.1 andCANS/CSA C743 I for all versions (which are based on AHRI standard rating conditions) and, therefore, also meets the LEED "Minimum Energy Performance" prerequisite Iln the Energy and. Atmosphere section. - The USED Green Building Rating System-, developed by the U.S. Green Building Council, i provides independent, third -party verification That a building project meets green buildina and p dmirriangemeaswes 3/17/2020 TOPSS version number 233 I r I I I i i Data generation date 3/17/2020 ( Pace of FLD = Furnished by Trans U.S. Inc. / Installed by Equipment Submittal Page 6 of 54 Others I 11 Structural Item I Tag(s)I City I Description I Model Number 131 AHU-whse 11 1 Performance Climate Changer CSAA CSAA080UB Product Data - Performance Climate Changer (CSAA) Item: 131 City: 1 Tag(s): AHU-whse Unit level options Outdoor unit Unit size 80 No 6in. integral base frame UL listed unit Single metal handle - ganged latches 142.63 Unit length Field Provided (mtrs, lights, controls) No seismic certification required Controls and VFD/starter Supply fan field provided VFD Return/exhaust fan no NEMA Energy wheel field provided starter or no wheel CDQ field, provided starter or no wheel Warranty Standard warranty only Pipe cabinet section No pipe cabinet YES YES YES YES YES YES YES YES YES YES YES YES Air mixing section (Pos #1) Air mixing section Mixing box w/filter Door- right side Back damper - parallel blade Front full face opening Left side - High velocity parallel 2in. filter frame Pleated media - run set (Fld) Coil section (Pos #2) Horizontal coil Medium Door- right side Stainless steel drain pan Left side - drain connection Left side - coil supply Service panel opposite connection side Unit coil height Cooling coil Chilled water Single use coil Type "UU" coil 4 rows 84 fins per foot nominal fin spacing Aluminum fins Others Amazon MEP StructuralDesl'. =.nazon DVB1 Delta flo H (Hi efficient) .016"(0.406 mm) copper tubes 1/2in. tube diameter (12.7 mm) Galvanized steel coil casing Turbulators Fan section (Pos #3) Fan section Supply fan Door- right side Outward swing 24.5in. dd plenum, full width, M press Higher efficiency 4 Fan quantity Plenum fan Right side drive NEMA premium compliant ODP Voltage 460/3 NEMA motor hps only 10 max applied hp 1800 RPM Inverter balance with shaft grounding Side rectangular discharge Field provided VFD Performance Data - Performance Climate Changer (CSAA) Tags AHU-whse Unit level options Position Length in 142.631 Width in 140.500 Hei ht. in 107.500 Rigging weight(lb) 7400.8 Installed weight(lb) 8081.7 Roof curb weight(lb) 401.2 Actual airflow cfm 40000 Unit elevation ft 0.00 Shipping split 1 weight(lb) 3965.1 Shipping split 2'wei ht(lb) 3715.4 Fan section Position #3 Section length in 61.478 Section weight(lb 3715.4 Fan airflow cfm 40000 Elevation ft 0.00 Overall ESP in H2O 2.000 Total static pressure in H2O 3.895 Maximum TSP 60 Hz in H2O 3.895 Fah pressure drop in H2O 2.319 Speed (rpm) 1752 Total brake horsepower h 37.084 Unit static efficient % 66.24 Motor hertz Hz 60 Discharge 1 side - airflow cfm 40000 Discharge 1 side - face velocity ft/min 1596 Discharge 1 side - pressure drop in H2O 0.319 Discharge 1 side - area (sq ft 25.06 Coil section Position 1#2 Section length in 27.028 I I I �fnazon DVB1 - I March 17. 2020 or bottom con ary weic nt Ib 355.2 I dry bulb F 60.84 wet bulb F 59.44 dry bulb F 80.40 I wet bulb F 70.80 no Inrs... EEKIT, 10.00 308.71 � 17.74 I 3.78 i j #1 in 54.000 (lb) 2216.9 k - airflow cfm 40000 it - airflow cfm 40000 - airflow cfm 20000 k - area (sq ft 30.83 it - area (sq ft 92.42 - area (sq ft 18.45 k - face velocity ft/min 1297 - face velocity ft/min 1084 k - pressure drop in H2O 0.273 - nraccure drnn (in H70) n nR3 V OI III ly I IOII JIUO Wltll PIUbb UIC UI UJJ k1lI nZV U.000 I Back hood pressure drop in H2O '0.220 Back hood area (sq ft 54.54 Back inlet type Unducted Left side inlet type Ducted Greatest entry PD in H2O 0.493 Filter condition Mid-life Filter airflow cfm 40000 Filter area (sa ft) 85.56 rLU = Others FLO =. Furnished by Trane U.S. Inc. /Installed by Equipment Submittal j j Page 29 Others ) I I Amazon MEP Structural Des...1,nazon oval March 1 Mechanical Specifications - Performance Climate Changer (CSAA) Item: 131 Qty: 1 Tag(s): AHU-whse GENERAL Outdoor air handling units will be shipped with all openings covered to protect unit interiors from in -transit debris Installing contractor is responsible for long term storage in accordance with the Installation; Operation, and Maintenance manual (CLCH-SVX07B-EN). Unit shall be UL and C-UL Listed. Supply fans within the scope of AHRI Standard 430 shall be certified in accordance with AHRI Standard 430. Unit sound performance data shall be provided using AHRI Standard 260test methods ah, d reported as sound power. Trane, in providing this program and data, does not certify or warrant NC levels. These levels are affected by factors specific to each application and/or installation and therefore unable to be predicted or certified by Trane. Refer to product data for specific fan footnote references. Unit Construction Outdoor unit roofs shall incorporate a standing seam on the exterior to ensure a rigid rooflconstruction and prevent water infiltration . Roof assembly shall overhang all walls by 1.5-inch minimum to prevent, sheeting from roof to side panels. Rain gutters shall also be provided overall doors shorter than total uhit height to direct rain away from the door assembly. Outdoor roofs shall be sloped, not less than 0.125 inches per foot, for water drainage. Where outdoor units are shipped in multiple sections, provide standing -seam joiners at each split with adhesive, hardware, and cover strips for field joining by the installing contractor. I All unit panels shall be 2" solid, double -wall construction to facilitate cleaning of unit interior. Unit panels shall be provided with a mid -span, no -through -metal, internal thermal break. Casing thermal performance shall be such that under 55OF supply air temperature and design conditions on the exterior of the unit of 81 OF dry bulb and 730F wet bulb, condensation shall not form on the casing exterior. All outdoor AHU interior casing panels will be made of galvanized steel. Unit Paint External surface of unit casing will be coated with water -based polyurethane paint. Color to be standard "Slate Gray". Factory -painted units will be able to withstand a salt spray test in accordance with ASTM b117 for a minimum of 500 consecutive hours and shall meet the following requirements following the salt -spray test it -Mean scribe creepage rating of at least 6 per ASTM D1654 procedure A - Blister size no larger than #6 per ASTM D714 - Blister density no greaterthan Medium per ASTM D714 I - No onset of red rust Casing Deflection I !I The casing shall not exceed 0.0042 inch deflection per inch of panel span at,1.00 times design static pressure. Maximum design static shall not exceed +8 inches w.g. in all positive pressure; sections and -8 inches w.g. in all negative pressure sections. 11 Floor Construction The unit floor shall be of sufficient strength to support a 300.0 lb load during maintenance more than 0.0042 inch per inch of panel span. Unit base Manufacturer to provide a full perimeter integral base frame for either ceiling suspension c all sections of the unit for proper trapping. Indoor unit base frame will either be bolted cos construction. All outdoor unit base frames shall be welded construction. For indoor units, height and construction type. Contractor will be responsible for providing a housekeeping not of sufficient height to properly trap unit. Unit base frames not constructed of galvanize cleaned and coated with both a rust -inhibiting primer and finished coat of rust -inhibiting e included in total height required for proper trap height. , and shall deflect no units or to support and raise Itruction or welded �fer to schedule for base sad when unit base frame is t steel shall be chemically amel. Unit base height to be Others Amazon MEP Panel insulation shall provide a minimum thermal resistance (R) value of 13 ft'-h °F/Btu throughout the entire unit Insulation shall completely fill the panel cavities in all directions so that no voids exist and settling of insulation is prevented. Panel insulation shall comply with NFPA 90A. 1 ;1 Drain Pan In sections provided with a drain pan, the drain pan shall be designed in accordance with ASHRAE 62.1. To address indoor air quality (IAQ) the drain pan shall be sloped in two planes promoting positive drainage to eliminate stagnant water conditions. Drain pan shall be insulated, and of double wall construction. The outlet shall be the lowest point on the pan, and shall be of sufficient diameter to preclude drain pan overflow under normally expected operating conditions. All drain pans connections shall have a threaded connection, extending a minimum of 2-1/2" beyond the unit base, and shall be made from the same material as the drain pan. Drain pan located under a cooling coil shall be of sufficient size to collect all condensate produced from the coil. Refer to Product Data for specific information on which sections are supplied with a drairi pan, the drain pan material and connection location. Access Door Construction Access doors shall be 2" double wall construction. Interior and exterior door panels shall be of the same construction as the interior and exterior wall panels respectively. All doors shall be provided with a thermal break construction of door panel and door frame. Gasketing shall be provided around the full perimeter of the doors to prevent air leakage. Surface mounted handles shall be provided to allow quick access to the interior of the functional section and to prevent through cabinet penetrations that could likely weaken the casing leakage and thermal perfonnance. Handle hardware shall be designed to prevent unintended closure. Access doors shall be hinged and removable for quick easy access. Hinges shall be interchangeable with the door handle hardware to allow for alternating door swing in the field to minimize access interference due to unforeseen job site obstructions. Door handle hardware shall be adjustable and visually indicate locking position of door latch external to the section. Door hinges shall be galvanized. All doors shall be a minimum of 60" high when sufficient height is available or the maximum height allowed by the unit height. j Door handles shall be provided for each latching,point of the door necessary, to maintain the specified air leakage integrity of the unit. Optionally for indoor AHUs and as standard on outdoor AHUs, outward swing doors are provided with a single handle linked to multiple latching points. An optional shatterproof window shall be provided in access doors where indicated on the plans. Window shall either be single pane, or thermal dual pane, as defined on schedule. Window shall be capable of withstanding unit operating pressures and shall be safe for viewing UV-C lamps. Refer to Product Data for specific information on which sections are supplied with an access door, the door location, a single handle and a window. Factory -supplied Curb Outdoor AHU will be provided with a factory -supplied roof curb. Curb will be shipped to jobsite disassembled. Contractor will be responsible for assembly and mounting to roof structure per the Roof Curb Manual. Units with factory -supplied external piping cabinet(s), the factory -supplied curb will include a curb section for the pipe cabinet(s). Refer to the Roof Curb Detail drawing and Product Data section of submittal for height of factory -supplied roof curb(s). MIXING SECTION A mixing section shall be provided to support the damper assembly for outdoor, return, and/or exhaust air. Dampers Dampers shall modulate the volume of outdoor, return, or exhaust air. The dampers shall be of double -skin airfoil design with metal, compressible jamb seals and flexible blade -edge seals on all blades. The blades shall rotate on stainless -steel sleeve bearings. The dampers shall be rated for a maximum leakage rate of 3 cfm/ft' at 1 in. w.g. complying with ASHRAE 90.1 maximum damper leakage. All leakage testing and pressure ratings shall be based on AMCA Standard 500-D. Dampers may be arranged in a parallel or opposed -blade configuration. Inlet Hoods Inlet hoods are provided on the outside air openings and equipped with high performance moisture eliminators to minimize water carryover from the outside into the unit casing. Eliminators also perform the function of a bird screen to prevent nesting. Refer to the unit As -Built and Product Data section for specific information on which sections are supplied with inlet hood. .I FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 31 of 54 Others mazon DVB1 Dampers shall modulate the volume of outdoor, return, or exhaust air. The dampers shall be of double -skin airfoil design with metal, compressible jamb seals and flexible blade -edge seals on all blades. The blatles shall rotate on stainless -steel sleeve bearings. The dampers shall be rated fora maximum leakage rate1of 3 cfMAt2 at 1 in. w.g. complying with ASHRAE 90.1 maximum damper leakage. All leakage testing and pressire ratings shall be based on AMCA Standard 500-D. Dampers may be arranged in a parallel or opposed -'blade configuration. Title 24 The following specifications apply only to units with outside air and return air, dampers, warranty applies only to these items. This unit contains Economizer that meets or exceeds all mandatory requirements pres not limited to: - 5 yr parts only warranty - Successfully tested to 60, 000 Actuations - Less than 10 cfm/sq.ft. of damper leakage at 1" WG per AMCA 500L Filters Mixing sections shall be provided with a filter rack as indicated in the Product Data and 2-inch pleated media filters made with 100% synthetic fibers that are continuously la grid with water repellent adhesive shall be provided. Filters shall be capable'of open without loss of filter efficiency and holding capacity. The filters shall have a MERV 8 with the ANSI/ASHRAE Standard 52.2. COIL SECTION WITH FACTORY INSTALLED COIL The coil section shall be provided complete with coil and coil holding frame. ;The coils st headers and return bends are enclosed by unit casings. If two or more cooling coils are intermediate drain pan shall be installed between each coil and be of the same material < the primary drain pan, the intermediate drain pan shall be designed being of sufficient sh produced from the coil and sloped to promote positive drainage to eliminate stagnant wa intermediate pan shall begin at the leading face of the water -producing device and be of downstream to prevent condensate from passing through the air stream of tfie lower coil. include downspouts to direct condensate to the primary drain pan. The outlet shall be loc pan and shall be sufficient diameter to preclude drain pan overflow undei any normally e actuators. The 5 year by Title 24, including but sections of the submittal. ad to a supported steel -wire p to 625 fpm face velocity when tested in accordance f be installed such that cked in the unit, an the primary drain pan. Like to collect all condensation conditions. The fficient length extending ntermediate drain pan shall ad at the lowest point of the ected operating condition. Coil with Inspection The coil section shall include an inspection section complete with a double -wall, removable door downstream of the coil for inspection, cleaning, and maintenance. Interior and exterior door panels 'shall be of the' same construction as the interior and exterior wall panels, respectively. All doors shall be provided with a thermal b,'reak construction of door panel and doorframe. In lieu of a door, an easily removable service panel shall be provided in sections as specified, to facilitate access to unit for periodic servicing, or for removal and replacement of coils. Removal of service panel will not impact the structural integrity of the unit. I Casing penetrations supplied for hydronic drain and vents. Piping contractor shall Water Coils (UP, WP, UW, UU, UA, 3W 3U, W, 5W, 5A, WD, 5D, D1, D2, P, or TT) The coils shall have aluminum fins and seamless copper tubes. Copper fins may be applil Fins shall have collars drawn, belled, and firmly bonded to tubes by mechanical expansio, may be galvanized or stainless steel. Refer to the Product Data section of the submittal i The coils shall be proof -tested to 300 psig and leak -tested under water to 200 psig. Coils glycol are certified in accordance with the AHRI Forced -Circulation Air -Cooling and Air-H Program which is based on AHRI Standard 410 within the Range of Standard Rating Cor, Standard. Certified units may be found in the AHRI Directory at wwwahndirectory.org. Ft chloride, or mixtures thereof, are outside the scope ofAHRI Standard 410 and, therefore, c or certification. Coil connections are constructed of cast iron with female connections, steel block with piping. i to coils with 5/8-inch tubes. of the tubes. The coil casing r the coil casing material. ontaining water or ethylene Sting Coils Certification itions listed in Table I of the pylene glycol and calcium not require AHRI 410 rating connections or steel pipe Others Amazon MEP Structural Des mazon DVB1 II ;, „f March 17,2020 with male connections. Type P or TT coil connections do not extend out of unit casing. All other water coil types have connections that extend out beyond unit casing. Headers on downstream coil bank of staggered coil sections do not extend beyond the unit casing and must be completed by the on -site piping contractor. 11 Tubes are 112"[13 mm] OD 0.016" [0.406 mm] thick copper. DIRECT -DRIVE PLENUM FAN SECTION The fan type shall be provided as required for stable operation and optimum energy efficiency. The fan shall be a single -width, single -inlet, multiblade-type direct -drive plenum fan. Motor bearing life of the direct -drive plenum fan shall be not less than L-10 250,000 his. Refer to the Product Data section for fan'and number of blades selected within each unit. Fans shall be certified as complying with AHRI Standard 430 for airflow performance. Fans shall be tested and rated in -accordance with AHRI Standard 260 for sound performance. Fans that are selected with inverter balancing shall first be dynamically balanced at design RPM. The fans then will be checked in the factory from 25% to 100% of design RPM to insure they are operating within vibration tolerance specifications, and that there are no resonant frequency issues throughout this operating range. Inverter balancing that requires lockout frequencies inputted into a variable frequency drive to in order to bypass resonant frequencies shall not be acceptable. If supplied in this manner by the unit manufacturer, the contractor will be responsible for rebalancing in the field after unit installation. Fans selected with inverter balancing shall have a maintenance free grounding assembly installed on the fan motor to discharge both static and induced shaft currents to ground. I On units supplied with plenum or motorized impeller fans, expanded metal door guard(s) shall be supplied on the 11 access door(s) to the fan and those downstream access door(s) where unintended access to the plenum or motorized impeller fan could occur. Door guard is intended to deter unauthorized entry and incidental contact with rotating components. Refer to the Product Data section for fans with access door guard(s).11 Motor Frame The motor shall be mounted integral to the isolated fan assembly and furnished by the unit manufacturer. The motor is mounted inside the unit casing on an adjustable base to permit adjustment of drive belt tension (not applicable for direct drive plenum fans). The motor shall meet or exceed all NEMA Standards Publication MGI1 requirements and comply with NEMA Premium efficiency levels when applicable except for fractional horsepower motors which are not covered by the NEMA classification. The motor shall be T-frame, squirrel cage with size, type, and electrical characteristics as shown on the equipment schedule. Refer to the Product Data section for seiected fan motors within each unit. Two -Inch Spring Isolators Direct -drive fan and motor assemblies shall be internally isolated from the unit casing with 2-inch (50.8 mm) deflection spring isolators. The isolation system shall be designed to resist loads produced by external forces, such as earthquakes, and conform to the current IBC seismic requirements. Lifting Instructions The air handling units must be rigged, lifted, and installed in strict accordance with the Installation, Operation, and Maintenance manual (CLCH-SVX07G-EN). The units are also to be installed in strict accordance with the specifications. Units may be shipped fully assembled or disassembled to the minimum functional section size in accordance with shipping and job site requirements. Outdoor units shall be shipped on 6" integral base frame for the purpose of mounting units on a roof curb or field -supplied pier support system. Refer to the Product Data section for type of the base'frame provided (for roof curb or pier -mount). J All units will be shipped with an integral base frame designed with the necessary number of lift points for safe installation. All lifting lugs are to be utilized during lift. The lift points will be designed to accept standard rigging devices and be removable after installation. Units shipped in sections will have a minimum of four points of lift. Others a D A— . 3tn3 95/81/4-13 o 4 W man � f 1 Opening left A M 82.000 x 44.000 2 Plenum fan -24.5In. old Ip N ■ plenum, full width, M press Supply fan 10 hp 460/3 " n None 03 2 3 - 5 T 6 126 1401/2 3 Cooling wil-4 Coil type i UU Damper left -parallel blade 88.000 x34.250 � O M4 y Y Q m r— ' 5 Damper back -parallel blade — = 3 40.000 x 123.000 C T 6 Head back N 7 Flat filters- S n a 20" 10' 23° 45 1I8 Doors N ID N 7 1/4 20 width x 61 height U3 Cy10 Width x 61 height t0 23 width x 97 height n � 7 t 79 1/2 107 1/2 6 45 1/8 15 7/8 61 112 81118 Ship Spli Ship Spli 37151bs 3965 lbs 142 5/8 For maneuvering purposes, Include 1.1251nches to each ship split length for ovedapping panel flange. Flange will not add to overall Installed unit length shown. OPENING AND DIMENSIONS MAY VARYFROM CONTRA CTOOCUMENTS/RETURN OFAPPROVED DRAWINGS CONSTITUTES ACCEPTANCE OF THESE VARWNCES/NOT TO SCALE Unit size: 80 OI7 Name: Unit Casing: 2m Double Wall Foam y e s Product group: Outdoorunit ctual airflow: 40000 cfm Proposal Number. Integral base frame: 61n. integral base frame Paint Slate gray loales Office: Rigging/Installed Weight: 7400.E Ib/ 8081.71b PUOnnarce fl ale tlunpea N,�em 0 0 / Amazon MEP Structural Delli _ +mazon DVB1 --, '1p As -Built - Performance Climate Changer (CSAA) Item: B1 Qty: 1 Tag(s): AHU-whse 3' ,72- 4 ; .-.IS2 .p� r_ N-1 •;i r - M2 Sib s { 6 Furmaneuvedng purposes„Include 1.125 Inch" to each ship split length for overlapping panel flange.: Fit area will not a to overall Installed unit length Pos # Module Length Weight 3 Fan section 61 1/2 3715.411 I 2 Coil section 27 1/8 1748.257 1 Air mixing section 54 2216.85'' f Installed Unit Weight 7680.51 Ibs f f I 1 1 r I Pmduct group!outdeor-dual airflow: 40000 cfm Proposal Number: ;I a imsaral ease(sofa: as, I. cullllease mama 1 I e.m�n.�,�ama.w,a Paint: Slate rmv iSales Office: TK08W aD81,71VI FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal j Others Amazon MEP Structural. DetL +mazon DVB1 I March 17, 2020 As -Built - Performance Climate Changer (CSAA) Item: B1 Qty: 1 Tag(s): AHU-whse j I � n w 0 v ' ... ... I iam - a �wi . • • ,�h . ILL Imo- 611;2 271/8—Ir— 54— I Right Side of Unit Detailed Plan,View: Top -' Measurements n inches di a elect Conn (NEMA) { I I • i j - I ' I Ti�3`s 1n • I I i I ' 1 i I 301/8 —271/8 I . 54 1 1 1/2 Left Side of Unit Detailed Plan View: Bottom - Measurements) in inches OPENINGANDDIMENSIONSMAYVARYFROMCON CTDOCUMERTS/RETURNOFAPPROVEDDRAWINGSCONSPTUTESACCEPTANCEOFTNESEVARIANOES/NOTTOSCALE Unit size: 60 Job Nagle: Unit Casing: tin Double Wall Foam Proposal Number. dual airflow: 40000 efm ip�ry •••W:R51• Protluclgroup: Outdoor unit Int,.1G ehere:".INegmlbaeName I Sales Office: alhainZl.awamrt vwnemr eoevlb;l Pnbmw fLnle CNryer NP,rCIc, PaInC Blategmy I I i I , l i I I FLD Furnished by Trane U.S. Inc./Installed by Equipment Submittal - it Page 36 of 54 Others Amazon MEP Structural De! ..amazon DVB1 -� r March 17 2020 As -Built - Performance Climate Changer (CSAA) j Item: B1. Qty: 1 Tag(s): AHU-whse IV _ N - . I n 3 3 3/e " 2 118 7 3/4 7518, 54 6 142 5/e rI f N. I O 9 T _• •� ..gyp _ 13 M�l MIL i m 13 a 9 v r L2 7 1/2 6 'W 27 1/8 1 1/ 54 j Detailed Elevation View: Left -Measurements in, inches i OPENINGANDDIMENSIONS M4YVARYFROMCONffi CTDOCUMEMS/RETURNOFAPPROVEDDR MNGSCONSTIT SACOEPTANCEOF.TRESEVARMCES/NOTTOSCALE Unit size,80 Job Name: Unit Casing 2mDouble Wall Fcam } Product group :Outdoor unit ctual airflow: 40000 cfm Proposal Number. imeaai ease name: su.Imegm ease name 7.m8m eW1.71e] IAIrYrW,n Paint; Slate gray ISales Office: r I FLD = Furnished by Tmne U.S. Inc. / Installed by Equipment Submittal Page 37 0/ 54 Others Amazon MEP Structural De;.mazon DV81 ��- As-Built - Performance Climate Changer (CSAA) Item: B1 Qty: 1 Tag(s): AHU-whse i Detailed Elevation View: Front - Measurements in inches I i i i I I i 1 1l'T m � N 15 7/8 7 1/4 Detailed Elevation View: Back - Measurements in inches { Name: ial airflow: 40000 cfm pmbmerca pmLe Qeryer FLO= Furnished by Tian U.S. Inc./Installed by Equipment Submittal Others 3 E� W N 3 00 pp 5. I z M O �su CD CD Q f I ML 1425/8 NPTI : National Pipe Thread Internal Connection NPTE : National Pipe Thread External Connection OPENING AND DIMENSIONS MAY VARYFROM CONTRACT DOCUMENTS/RETURN OFAPPROVED DRAWINGS CONSTITUTES ACCEPTANCE OF THESE VARIANCES /NOT TO SCALE Unit size: 80 JOb Name: jUnit Casing: 21n Double Wall Foam i ` e Product :Outd dual airflow: 40000 cfm Pro osal Number baSegmupfM a 6irunit Integral base bir. integral base frame Paint: Slate gray Sales Office: RiggingAnstalleo Weight: 7400.8lb/ 8081.71b v.m.,.ke coma. w,a, I 1 m y W D H 3 A M v �54 271re 11/2� •• .a 0 y e .. •. � n A m �3/8 .y^.. c:K • iOo Return _ T =r N N C 2.5" (N- Su Ply, f0 m ca • ��J W dram (NPTI D ' ;ei ire 83/ s X i X ,.. 345/8 s> - 31 112 i Coil Connection view: Left- Measurements in inches NPTI : National Pipe Thread Internal Connection NPTE : National Pipe Thread External Connection OPENING AND DIMENSIONS MAY VARYFROM CONTRACT DOCUMENTS/RETURN OF APPROVED DRAWINGS CONSTITUTES ACCEPTANCE OF THESE VARIANCES/NOT TO SCALE Unit size: 80 JOl) Name: jUnit Casing: tin Double Wall Foam m ° Pratlud grou :Duttloor unll Integral base frame: bir. integral base forme ctual airflow: 40000 cfm Pro osal Number. Paint: Slate gray pales Office: Rigging/Installed Weight: 7400.8 IN 8081.7Ib r:�w,�.z. coma. c" uiwom.. V N N 0 Amazon MEP Structural Dell mazon DVB1 - -{ j March 17 2020 As -Built - Performance Climate Changer (CSAA) Item: B1 Qty: 1 Tag(s): AHU-whse I 1 i i �Y< z ' W U g I Q W i � E W t a I o I U 2 m E a l °w o m 0 1 U LL P rt m r = C N ` E {V � 4a U o n c o 2 N U m I o O � I 1 V 2 1 M 3 i 0 U E m O 75 i to 0 N W m o E � I 2 m � ¢ a 1 2 2 � • �m 1 O e I "gym @ • �eNv 2 y a i �'N a_a c I I 1 FLO = Fumished by Trane U.S. Inc. / Installed by Equipment Submittal �i Page 41 of 54 Others r , I , Certificate of Product Ratings AHRI Certified Reference Number: 201986574 Date: 02-27-2020 Model Status : Act ve Brand Name: DELTA-FLO E AND DELTA-FLO H Model Number: UP/C/E10.500 lol1.250x1.0821furbulator/SineWave/Delta Flo E i I Coll Line Designation: UP I Function :Cooling (C) I Fluid Type: Ethylene Glycol & Water (EG&W) I ; Tube Outside Diameter: 0.500 i Does this coil require a header?: Yes Header: 1.500; 2.000 Certified Row(s) : 2, 4, 6, 8 ' I Tube Spacing across Coil Face (Stf) X Tube Spacing between Coil Rows (Str) : 1.250 X 1.082 Tube Internal Construction :.Turbulator Manufacturing Location : Columbia South Carolina " r. . Fin Configuration : Sine Wave Rated as follows in accordance with the latest edition of AHRI.. Standard 410 Forced -Circulation Air -Cooling and 'r-Heating Coils and subject to rating accuracy by AHRI-sponsored, independent, third party testing: 9 Software: Name:.. TOPSS t Software Version: Update 231' " 6 }"Active" Model Status are those that an AHRI Certification Program Participant is currently producing AND. selling or offering for site; OR new models that are being marketed but are not yet being produced."Production Stopped" Model Status are those that an AHRI Certification Program Particip'+ent is no longer producing BUT is still setRaingorofleringfor sale. _ i I Ratings that are accompanied by WAS indicate an involuntary re -rate The new Deblished rating is shown along with the orevious (i.e. WAS) ratina. DISCLAIMER I' AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or pe' ormance of the product(s), orthe unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed In the directory at www.ahrldliectory.org. + TERMS AND CONDITIONS This Certificate and Its contents are proprietary products of AHRI. This Certificate shall only be used for Individual, personal and confidential reference purposes. The contents of this Certificate may not, In whole or In part, be reproduced; copied; disseminated; entered Into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's Individual; personal and confidential reference. it AIRCONOITIONING, HEATING, CERTIFICATE VERIFICATION t & REFRIGERATION INSTITUTE The Information for the model cited on this certificate can be verified at www.ahrldimetory.org, click on "Verify Certificate" Iiok we make life better - and enter the AHRI Certified Reference Number and the date on which the certificate was Issued, it which is listed above, and the Certificate No., which is listed at bottom right i, l - ©2020Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 1322ne59922649729 CERTIFIED" www.ahr.ldir;Story.org Certificate of Product Ratingf AHRI Certified Reference Number: 8321947 Date: 02-27-2020 Model Status : Acti Brand Name: TRANE PERFORMANCE CLIMATE CHANGER Model Number: CSW**- BMG 5 Rated as follows in accordance with the latest editions of AHRI Standard 430 (I-P) and AHRI Standard 431 (SI) for Central Station Air -Handling Unit Supply Fans and subject to rating accuracy by AHRI-sponsored, independent, third parry testing: Configuration : Ducted Fan Discharge Supply Fan Type: Housed Fan Geometry: Airfoil/Backwards-Inclined Drive Type : Belt -drive Software Name: Trane Official Product Selection (TOPSS) Software Version : Citrix Customer Version t"Active" Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offer marketed but are not yet being produced."Production Stopped' Model Status are those that an AHRI Certification Program DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, a the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or pe unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed In tl directory at www.ahrldlrectory.org. TERMS AND CONDITIONS This Certificate and Its contents are proprietary products of AHRI. This Certificate shall only be used for Individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminat entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individua personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahrldlrectory.org, click on "Verify Certilicate" li and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above, and the Certificate No., which is listed at bottom right. [ ©2020Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE N OR new models that are being s no longer producing BUT is still s no responsibility for, of the product(s), or the AIR-CONDITIONING, HEATING, & REFRIGERATION INSTITUTE we make life better^ 132272957709676552