HomeMy WebLinkAboutproduct approval2/13/2020 Florida Building Code Orlin
Bus i : o e
adS Home I Log In I User Registration I Hot Topic I Submit Surcriarge I Stalls &Farts I
h FIO(If'q °(' Product Approval
't: k r ❑ USER: Public User
Pmdvtt Aepm al Menu > Pmdutt or Anol"aHon Search > [policazion Ust > Application Detbll
FL #
FL20745-R1
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Archived
Product Manufacturer Extreme Metal
Address/Phone/Email -
Palm City, FL 34990
(772) 872-8034
'Authorized Signature Richard McKuhen
Technical Representative Richard McKuhen
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
richard@emfab.net
Quality Assurance Representative
Address/Phone/Email
• 4al U ..
'ublictlom I ContaR Us I 6CIS Site Map I Unk I • Search I
I
LLC
Category Structural Components)
Subcategory Roof Deck
Compliance Method Evaluation Report from,a Florida Registered Architect or a Licensed Florida
Professional Engineer I
- Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the LOCKE BOWDEN
Evaluation Report
Florida License
PE-49704
Quality Assurance Entity
Keystone Certifications,
Inc.
Quality Assurance Contract Expiration Date
04/22/2024
Validated By
Zachary R. Priest, P.E.
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
{ Validation Checklist Hardcopy
ASTM E1592
FiEVIEWE® FOR
30®Er COMPLIANCE
ST. LUCIE COUNTY
BOCC
i
1/2
2113/2020
•
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
I
Florida Building Code Online
U
Method I Option D
08/18/2017
08/25/2017 i
08/28/2017
10/10/2017
FL #
Model, Number or Name
Description)
20745.1
(1) EMAX Rib
26 gauge steel,
lapped roof panel mechanically attached to
steel puriins
Limits of Use
Installation'Instructiuns I
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
FL20745 Rig II FL 20745.1 EXMAX RIB 26GA-ssr pl f
Verified By: ,Locke Bowden;, P.E. 49704
Impact Resistant: No
Design Pressure: +N/A/-110 max.
Created by Independent Third Party: Yes
Evaluation Reports
Other: Refer to evaluation report for conditions and limitations
of use. Refer to manufacturer's Installation instructions.
FL20745 R1 AE FL 20745 1 EXMAX RIB 26GA-ssr pdf
Created by Independent Third Party: Yes
20745.2
(2) PBR MAX
26 gauge steel, lapped.roof.'panel mechanirally:attached to
steel puriins I i
Limits of Use
Installation Instructions'
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/-105
Other: Refer to evaluation report for conditions and limitations
of use. Refer to manufacturer's installation Instructions.
FL20745 Ri II FL 20745.2 PBR RIB 26 GA-5sr.pdf
Verified By: Locke Bowden; P.E. 49704
Created by Independent Third Party: Yes
Evaluation Repr[s
FL20745 Rl AEaFL 2,74.12 PBR RIB 26 GA-ssr Ddf
Created by Independent Third Party: Yes
o N--
Contact Us :: 2601 Blalr Stone Road. Tallahassr nT
The State of Florida Is, an AA1EE0 employer. Coovd lit 2007-2013 State of Florida :: Priva,
Under Florida law, email addresses are public records. If you do not want your e-mall address rate
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any quest
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must proud
provided may be used for official communication with the licensee. However email addresses are p
provide the Department with an email address which an be made available to the public. To deten
Product Approval Accepts:
Mll�T-11 N—il—=l ElF
Credit Card
Safe
Phone: 850487-1824
Itatemen :: A¢essibiliN Statement:: Refund Statement
d In response to a public -records request, do not send electronic
please contact 850.487.1395. -pursuant to Section 455.275(1),
e Department with an email address If they have one. The emails
if you are a licensee under
212
Palm City, Fl. 34990
Compliant with Florida Building Code 2017 (611 ed.)
Compliant with Florida Product Approval Rule # 611320-3
Compliant: Quality Assurance Program
Product: PBR Rib 26 GA Steel Roof Panel-FBC Sec. 2507.4.2
yield strength: 50 ksi min.; Attached to Steel Purlins� with screws.
36" Coverage
Rib Height 1-1/4"
Corrosion Resistant Compliant: FBC Sec.1507.4.3
Fastener for Method 1 Attachment:12 —14 x 1-1/4" Hex -Was her Head, self -drilling screw
with WSW to penetrate 3/4" min. thru bottom of support (thru flange of steel purlins).
Fastener for Method 2 Attachment: #14 X 7/8" Hex -Washer Head, self drilling screw with
WSW to penetrate 3/4" min. thru bottom of support (thru flainge of steel purlins).
Underlayment: To be compliant with FBC Sec. 1507.1.1
Slope: Shall be in compliance with FBC Sec. IS07
Install Details: Table A Allowable Loads
METHOD 1
METHOD 2
DESIGN PRESSURE*
-45.5 PSF
PURLIN SPACING
60"
24"
FASTENER SPACING (ALONG PANEL WIDTH)
See Details
See Details
FASTENER SPACING (ALONG PANEL LENGTH)
20" I
12"
FASTENER SIZE:
12-14 X 1-1/4"
14 X 7/8"
SPAN CONDITION
3 OR MORE 13
OR MORE
Reference Data: ARCHITECiURALTESTING, INC. TST ID#:1527
ASTM E 1592-051 Test Report F8274.02-450-44
Equivalency Statement: 1. Ate ASTM E 1592-05 is equivalent to test sta I dard ASTM E 1592-12.
*DESIGN PRESSURE SAFETY MARIGIN = 2:1
Certificate of I d d
n epen ence.
Locke Bowden, P.E. does not have, not will acquire a financial interest In gPky.wmpagyjmanufacturing or distributing products
under this evaluation. .�� ,Q y . 1rr
Locke Bowden, P.E. is not owned, operated, or controlled 6 an gk u r+
Y Y �arj ryJoWartUtdr3dr distributing products under this
report. 5.;+ ..
10,5/� �
;r
4
FI20745.2 PAMAX (26GA Steel),
36" WiQJRoof Panel - Details
i
Limitations:
1. Underlayment to be compliance with current Florida Building Code (FBC)2017
2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and pr
3. Products are compliant for State of Florida product approval per Rule 61 G20-3
4. Engineering analysis for "project specific approval by local authorities w/ jurisd
5. Fire classification is not part of this acceptance. Shear diaphragm values are o
6. Support framing in compliance w/FBC 2017 6'h ed., Chapter 22 Steel, Chapter
7. This report does not imply warranty, installation, recommended product use oL
'h ed..
with Manufacturer's installation reference.
Compliance' Method: 1-D
tion is allovaed by other registered engineers.
tside this report.
3 Wood and Chapter 16 Structural Loading.
As of this ieport.
I _l
fw�ot I
rad wt�c, moa.ic�