Loading...
HomeMy WebLinkAboutREVISIONSOFFICE USE ONLY: % (i DATE FILED: b t � 3 PERMIT # o�$ REVISION FEE: D 0 RECEIPT # tr LOCATION/SITE ADDRESS: 170 PLANNING & DEVELOPMENT SERVI S, BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 (772)462-1553 APPLICATION FOR BUILDING PERMIT REVISIO S PROJECT INFORMATION AJ 37 z5` F-O e f,F--�, _3c/%y7 2. DETAILED DESCRIPTION OF PROJECT REVISIONS• 41s 4P 3. 4. 5. CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: _ BUSINESS NAME: QUALIFIERS NAME: ADDRESS: CITY: PHONE (DAYTIME): OWNER/BUILDER INFORrrMATIZ641 NAME: bend-'1 ADDRESS: 3.0 7 34 CITY: < a PHONE: ) % 4(0— ? J _ ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: PHONE (DAYTIME): SLCCC: 9/23/09 Revised 04/26/2010 ST. LUCIE COUNTY CERT. #: STATE: 'FAX: STATE: STATE: FAX: FAX: ZIP: ZIP: ZIP: f N(vv + 4 1,101- o JAI FORM 405-10 RECEIVED MAY4, 310q FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: NOBLE RESIDENCE Builder Name: Sheet City, State, Zip: FT. PIERCE, FL, Permit Officer Permit Number: Gamer. Jurisdiction: t" k D sign Location: FL, Fort Pierce ?' 1. New construction or existing New (From Plans) 9. Wall Types (2752.0 sqft.) Insulation Area a. Concrete Block - Ext lnsul, Exterior R=5.0 2752.00 ft' 2.:23ingle family or multiple family Single-family b. NIA R= ft2 3. Number of units, if multiple family 1 c. NIA R= ft2 4. Number of Bedrooms 4 d. N/A 10. Ceiling Types (2618.0 sqft.) R= ft2 Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=19.0 2618.00 ftz 6. Conditioned floor area above grade (ftz 2618 b. NIA R= ftz ft2 c. N/A R= Conditioned floor area below grade (ft) 0 11 Ducts R ft2 7. iA indows(356.7 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 205 6 85 a. U-Factor: Sgl, U=0.65 356.67 ftz b. Sup: Attic, Ret: Attic, AH: Attic SHGC: SHGC=0.30 12. Goofing systems kBtu/hr Efficiency h. U-Factor: WA a. Central Unit 46.0 SEER:15.00 SHGC: b. Central Unit 17.0 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 46.0 HSPF:7.70 SHGC: b. Electric Heat Pump 17.0 HSPF:7.70 Area Weighted Average Overhang Depth: 5.095 ft. Area Weighted Average SHGC: 0.300 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (2618.0 sqft-) Insulation Area EF: 0.920 a. Slab -On -Grade Edge Insulation R=0.0 2618.00 ft2 b. Conservation features 13. WA R= ft2 None .;. N/A R= ft2 15. Credits Total Proposed Modified Loads: 41.44 PASS Glass/Floor Area: 0.136 Total Standard Reference Loads: 52.68 I hereby certify that the plans and specifications covered by Review of the plans and OFTKE SrAT�, this calculation are in compliance with the Florida Energy specifications covered by this Cade. calculation. indicates compliance with the Florida Energy Code. , tt t'�. -:: i:: `' �« O evisv is -- a PF2EPAREC2 BY: Before construction completed"- 94 DATE: "7 this building will be inspected for compliance with Section 553.908 0 �•„ a .... I hereby certify that this building, as designed, is in compliance Florida Statutes. ryC''' fJp with the Florida Energy Code. OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: � °r d _ u a,• f - 5110/201310:12 AM ion 405.4.1 Compliant Software Page 1 of 6 E PROJECT _ Title: NOBLE RESIDENCE Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2618 Lot # . Owner: Total Stories: 1 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: Permit Office: Cross Ventilation: Yes County: ST. LUCIE COUNTY 'Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/E)asting: New (From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_ST_LUCIE_CO_INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Block1 2014 16112 2 Block2 604 4832 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2014 16112 Yes 2 3 1 Yes Yes Yes 2 MASTER BEDROO 604 4832 No 2 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 225 ft 0 2014 ft' ---- 0 0 1 2 Slab -On -Grade Edge Insulatio MASTER BEDRO 95 ft 0 604 ft2 _-__ 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2836 ft2 0 ft2 Medium 0.96 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2618 ft2 N N 5/10/2013 10:12 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6 CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic (Vented) Main 19 2014 ftz 0.11 Wood 2 Under Attic (Vented) MASTER BEDRO 19 604 ft' 0.11 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below :1 Omt Tn Space Wall Type 1 N Exterior Concrete Block - Ext Insul Main 5 50 8 400.0 ft2 0 0 0.75 0 2 E Exterior Concrete Block - Ext Insul Main 5 57 8 456.0 ft' 0 0 0.75 0 3 S Exterior Concrete Block - Ext Insul Main 5 50 8 400.0 ft' 0 0 0.75 0 4 W Exterior Concrete Block - Ext Insul Main 5 57 8 456.0 ft2 0 0 0.75 0 _ 5 N Exterior Concrete Block - Ext InsMASTER BE 5 14 8 112.0 ft2 0 0 0.75 0 6 E Exterior Concrete Block - Ext InsMASTER BE 5 51 8 408.0 ft' 0 0 0.75 0 `$ 7 S Exterior Concrete Block - Ext InsWASTER BE 5 14 8 112.0 ftz 0 0 0.75 0 8 W Exterior Concrete Block - Ext InsMASTER BE 5 51 8 408.0 ft2 0 0 0.75 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Insulated Main None 0.460000 6 6 8 40 ft' WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 1 Metal Single (Tinted) Yes 0.65 0.3 90.0 ft2 10 ft 0 in 6 ft 0 in Drapes/blinds None 2 N 1 Metal Single (Tinted) Yes 0.65 0.3 9.0 ftz 10 ft 0 in 6 ft 0 in Drapes/blinds None 3 E 2 Metal Single (Tinted) Yes 0.65 0.3 9.0 ft' 10 ft 0 in, 6 ft 0 in Drapes/blinds None 4 E 2 Metal Single (Tinted) Yes 0.65 0.3 30.0 ft' 10 ft 0 in 6 ft 0 in Drapes/blinds None 5 S 3 Metal Single (Tinted) Yes 0.65 0.3 20.0 ft2 2 ft 0 in 6 ft 0 in Drapes/blinds None 6 W 4 Metal Single (Tinted) Yes 0.65 0.3 53.3 ft2 2 ft 0 in 6 ft 0 in Drapes/blinds None 7 W 4 Metal Single (Tinted) Yes 0.65 0.3 15.0 ft2 2 ft 0 in 6 ft 0 in Drapes/blinds None 8 N 5 Metal Single (Tinted) Yes 0.65 0.3 53.3 ft2 2 ft 0 in 6 ft 0 in Drapes/blinds None 9 S 7 Metal Single (Tinted) Yes 0.65 0.3 30.0 ft2 2 ft 0 in 6 ft 0 in Drapes/blinds None 10 W 8 Metal Single (Tinted) Yes 0.65 0.3 30.0 ft2 2 ft 0 in 6 ft 0 in Drapes/blinds None 11 W 8 Metal Single (Tinted) Yes 0.65 0.3 9.0 ft2 2 ft 0 in 6 ft 0 in Drapes/blinds None 12 W 8 Metal Single (Tinted) Yes 0.65 0.3 8.0 ft2 2 ft 0 in 6 ft 0 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 441 ftz 441 ft2 42 ft 8 ft 11 5/101201310:12 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6 INFILTRATION -# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Best Guess 0.000500 3433.52 188.496 354.494 0.36500 9.83630 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts pnvali Electric Heat Pump (hvaliElectric Heat Pump None None HSPF: 7.7 46 kBtu/hr HSPF: 7.7 17 kBtu/hr 1 2 sys#1 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts pnvali Central Unit @nvaliCentral Unit None None SEER: 15 46 kBtu/hr 1380 cfm 0.75 SEER: 15 17 kBtu/hr 510 cfm 0.75 1 2 sys#1 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.92 40 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / — Supply — v # Location R-Value Area — Return— Air CFM25 Location Area Leakage Type Handler CO2125 OUT QN RLF HVAC # Heat Cool onvali Attic 6 205 ft2 (nvali Attic 6 85 ft2 Attic Attic 20 ft2 Default Leakage Attic (invalid) cf (Default) 20 ft2 Default Leakage Atfic (invalid) cf (Default) 1 1 2 2 TEMPERATURES Programable Thermostat: Y CoolingJan [ ] Feb Mar HeatinJan [ Feb X Mar Ventin Jan [ ] Feb X Mar Ceiling Fans: [ ] Apr [ ] May rj Jun jXj JUI rX Au [X] Se r Oct [ ] Apr [ ] May L ] Jun Jul l AuL ] Sep [ ] Oct [X] A r [ ] Ma [ ] Jun Jul [[ jjj Aug [ j Se [[[XXX]]] Oct Nov X Nov X Nov Dec Dec Dec 5/10/2013 10:12 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6 Thermostat Schedule: Schedule Type HERS 2006 Reference 1 2 3 4 5 Hours 6 7 8 9 10 11 12 -Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 �ieating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 I v 5/10/2013 10:12 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method I ADDRESS: PERMIT #: FT. PIERCE, FL, MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full deili, COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate.heating controls and cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. r Ceilings/knee walls 405.2.1 R-19 space permitting. 5/10/2013 10:12 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 6 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 79 The lower the EnergyPerformance Index, the more efficient the home. FT. PIERCE, FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family b. Concrete Block - Ext Insul, Exterior R=5.0 2752.00 ft2 b. NIA R= ft2 3. lumber of units, if multiple family 1 c. NIA R= ft2 4. lumber of Bedrooms 4 d. NIA R= ft2 10. Ceiling Types Insulation Area 5. s this a worst case? No a. Under Attic (Vented) R=19.0 2618.00 ft2 6. :,onditioned floor area (ft2) 2618 b. NIA R= ft c. NIA R= ft2 7. 'Mindows** Description Area 11. Ducts R ft2 a. U-Factor: Sgl, U=0.65 356.67 ft2 a. Sup: Attic, Ret: Attic, AH: Attic 6 205 SHGC: SHGC=0.30 b. Sup: Attic, Ret: Attic, AH: Attic 6 85 b. U-Factor. NIA ft2 SHGC: 12. Cooling systems kBtu/hr Efficiency U-Factor: N/A ft2 a. Central Unit 46.0 SEER:15.00 SHGC: b. Central Unit 17.0 SEER:15.00 1. U-Factor: N/A ft2 13. Heating systems kBtulhr Efficiency SHGC: a. Electric Heat Pump 46.0 HSPF:7.70 J4rea Weighted Average Overhang Depth: 5.095 ft. b. Electric Heat Pump 17.0 HSPF:7.70 Area Weighted Average SHGC: 0.300 8. Floor Types Insulation Area 14. Hot water systems Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 2618.00 ft2 a. Electric EF: 0.92 b. N/A R= b. Conservation features rc � c. NIA R= None � 15. Credits 1 certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code complipnt feature§, 4 .,uilder Signature: Address of New Home: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. "*Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. le EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Project Job_: -�- wrightsoft Pt S AHU 1 QUICK CALCS, INC. {y 317 ST. LUGE LN., FT. PIERCE, FL34946 Phone: 772-466-6799 Fax 772-466.6796 Email: QUICKCALCS@PAL.COM For. NOBLE RESIDENCE Weather. Fort Pierce, FL, US Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 18478 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 18478 Btuh Infiltration Method Construction quality Fireplaces Area (ft2) Volume (W) Air changes/hour Equiv. AVF (cfm) Simplified Average 0 Heating Cooling 2025 2025 16196 16196 0.26 0.13 70 35 Heating Equipment Summary Make Goodman Mfg. Trade GOODMAN, JANITROL, AMANA DISTI. Model GSZ140481A* AHRI ref no.4514279 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 8.8 HSPF 47000 Btuh @ 470F 27 OF 1567 cfm 0.085 cfm/Btuh 0 in H2O Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range Relative humidity L 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 30764 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 29225 Btuh Latent Cooling Equipment Load Sizing Structure 2869 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Equipment latent load 2869 Btuh Equipment total load 32094 Btuh Req. total capacity at 0.70 SHR 3.5 ton Cooling Equipment Summary Make Goodman Mfg. Trade GOODMAN, JANITROL, AMANA DISTI... Cond GSZ140481A* Coil AVPTC426014A* AHRI ref no. 4514279 Efficiency 13.0 EER, 15 SEER Sensible cooling 32900 Btuh Latent cooling 14100 Btuh Total cooling 47000 Btuh Actual air flow 1567 cfm Air flow factor 0.051 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.91 v Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrightSOft' RightSufte® Universal 2012 12.0.07 RSuPage o8101 2013-May 10 09:age 1 1 ACCA C:\Users\Quidc Calos\Documents\Wrightsoft WAC\NOBLE RES..rup Cale = MJ8 Front Moor faces: N -�- wrightsoft" Project Summary AHU 2 QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL34946 Phone: 772-466-6799 Fax 77246"796 Email: QUICKCALCS@AOL.COM Weather. Fort Pierce, FL, US Winter Design Conditions Outside db Inside db Design TD Job: Date: 4q Y. Summer Design Conditions 42 OF Outside db 70 OF Inside db 28 OF Design TD Daily range Relative humidity Moisture difference Heating Summary Structure 9265 Ducts 0 Central vent (0 cfm) 0 Humidification 0 Piping 0 Equipment load 9265 Infiltration Method Construction quality Fireplaces Area (ft2) Volume (ft3) Air changes/hour Equiv. AVF (cfm) 90 OF 75 OF 15 OF L 50 % 61 gr/lb Sensible Cooling Equipment Load Sizing Btuh Structure 11424 Btuh Btuh Ducts 0 Btuh Btuh Central vent (0 cfm) 0 Btuh Btuh Blower 0 Btuh Btuh Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 10853 Btuh Simplified Average 0 Heating Cooling 604 604 4828 4828 0.52 0.26 42 21 Heating Equipment Summary Make Goodman Mfg. Trade GOODMAN, JANITROL, AMANA DISTI. Model SSZ140181A* AHRI ref no.4431292 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow. factor Static pressure M Space thermostat 8.5 HSPF 18000 Btuh @ 47°F 26 OF 633 cfm 0.068 cfm/Btuh 0 in H2O Latent Cooling Equipment Load Sizing Structure 873 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Equipment latent load 873 Btuh Equipment total load 11726 Btuh Req. total capacity at 0.70 SHR 1.3 ton Cooling Equipment Summary Make Goodman Mfg. Trade GOODMAN, JANITROL, AMANA DISTI... Cond SSZ140181A" Coil AVPTC183014A' AHRI ref no. 4431292 Efficiency 13.0 EER, 15 SEER Sensible cooling 13300 Btuh Latent cooling 5700 Btuh Total cooling 19000 Btuh Actual airflow 633 cfm Air flow factor 0.055 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.93 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. �- p�,�_ WI'1 11tS0 2013-May-1009:12:34 .t ' (" g RightSuite® Universal 2012 12.0.07 RSU08101 Page 2 mil\ C:\Users\Quick Calcs\Documents\Wrightsoft HVAC\NOBLE RES..rup Calc = MJ8 Front Door faces: N ` -�- wrightsoft, Right-M Worksheet Job: AHU 1 Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL34946 Phone: 772-466-6799 Fax 772 166-6796 Email: QUICKCgLCS@AOL.COM V Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wri htsoft' 2013-May-10 09:12:34 9 RightSuite® Universal 2012 12.0.07 RSU08101 Page 1 A%A C:\Users\Quidc Calcs\Documents\Wrightsoft HVAC\NOBLE RES..rup Calc = MJ8 Front Door faces: N - wrightsoft® Right-JO Worksheet Job: AX 9 Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name LIVING BATH 2 2 Exposed wall 9.0 ft 0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 479.0 ft 479.0 ft2 10.0 x 6.0 ft 50.0 ft2 Ty Construction number U-value (Btuh/ft2-°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 13A-0ocs 6.125,.,n,. 3,60 222 0 "' 0' ' 0 6 6 0,' 0 '0 IA-clom 1.270 ..n• 35.56 34.77 .0., 0 0 " -6 0 0 0 . 0 11 1/✓ t-G 13A-5ocs IA-clom 13A-5ocs 1Aclom. 11 D0 0.125 1.270 0.125 1.270 0.390 ne ne e" a e' 0.00 0.00 3.56 35.56 10.92 0.00 0.00 2.22 .-91.12 11.31 0 0 0° 0 0 0 0 0 0 0 0 0 10 0.- 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -G r. D WI - L-G 13A5ocs 1A-c1om 13A5ocs `.: 1Aec1 om 1A1omd - 1 D c2om 0.125 1.270 6.125 1.270 : 9.270 0.870 se se s ` s' s s. 0.00 0.00 - • 3:50 35.56 35:56 0;� 0.00 0.00 ,2:22 34.77' 34.77 0.00 0 0 0 01 0;_ 0; 0 0 ; 0 0 0 0 0 0 0 0, 0` 0 0 0 p , p Q 0., 0 0 6, p. 0 • 0 0 0 p p 0 p- 0 0 p .. p 0 0 0 0 .: 0 0 0 0 1Dc2om'.. 13A5ocs 0.870 0.125 .• s sw _ 0.01) 3.50 .. _ 0.00 2.22 " 0 0 '" 0 0 , 0 0 0 6 0 0 ' :: 0 0 '- ., 0 0 , . °0 0 V�J 1Ac1om 13A-5ocs IA-clom 1 D-c2om 1.270 '-`_0 ' 125 1.270 ' 0.870 sw w . w - w. 35.56 ; 3.50 35:56 24:36 70.95 2.22 91•:12 77.43 0 72 30 10 0_ . '. 42 0 0 0 147' 1067 0 0 93 2734 0 0 . 0' . ` 0 0, 0 0 - 0 0 0 0 ; 0 0 0 ' 0 0 0 I-G �G W , L-G , 13A-5ocs 1Aclomd 12C.-0sw .:. 0.125 1.270 0.091 nw nw . - 0.00 0.00 2.55 0.00 0.00 :- _T28 ' 0 0 , :, ` .'0 0 0 0 0 0 0 0 0 0 0 0 `` 0 0 0 .. 0 0 0 . -p 0 0 0. P . C 1613-19ad 0.049 - 1.37 2.57 479 479 657 1232 50 50 69 129 F ,. 21A-20c c. 0.627 - 0.76 .. 0.00..-, . ` 479 479 362 .. 0 50 .:. 50 ., ': ` ` '38 : , 0 6 c)AED excursion 872 -0 Envelope loss/gain 2233 4931 106 123 12 a) Infiltration 130 35 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 2400 0 Subtotal (lines 6 to 13) 2363 7826 106 123 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 121 82 75 51 14 Subtotal 2484 7908 182 174 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 Total room load 2484 7908 1 182 174 Air required (cfm) 211 403 15 9 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-May-10 09:12:34 wrightsoft RightSuite® Universal 2012 12.0.07 RSU08101 Page 2 ACC " C:\Users\Quidc Calcs\Documents\wrightsoft HVAC\NOBLE RES..rup Calc = MJ8 Front Door faces: N -- wrightsoft® Right ; ® Worksheet QUICK CALCS, INC. 317ST. LUCIE LN., FT. PIERCE, FL34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICK04LCS@PAL.COM Job: Date: By: 1 Room name BEDROOM 2 HALL 2 Exposed wall 21.0 ft 0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heaUcool 4 Room dimensions 13.0 x 12.0 ft 3.0 x 13.0 ft 5 Room area 156.0 ftz 39.0 ft' Ty Construction U-value Or HTM Area (ft) Load Area (ftz) Load number (Btuh/ft2-"F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 I VVi �om n 3:50 2.22 ' •. 0 . ,.. .O . 0 °' 0 '0 0 . b 0 -, 1A 1. 16.270 n 35.56 3477 . 0 0 G -0 0 .. ': 0 0 0' yJ 13A-5ocs 0.125 ne 0.00 0.00 0 0 0 0 0 0 0 0 ' C 1Aclom. 1.270 ne_ 0.00 0.00 0 0 0 0 0 0 0, 0 11 13A-5ocs 0.125 a _ 3.50 2:22 ' , ` 104 84 294 187 0 0 0 0'. -- G '1A c1om: 1.270 a 35.56 91.12 20 0 . • 711 1,822, D 0 0 0 L-D 11 D0 0.390 e. 10.92 : 11.31 0-, 0 0 '.` 0 !0 0 0 • 0 WI 13A-0ocs 0.125 se 0.00 0.00 0 0 0 0 0 0 0 0 - L-G 1Ac1om se 0.00 0.00 0 0 0 0 0 _ 0 0 0 13A-5ocs „ _1.270 0A25 s 3.50 2.22 , 64 _ _ _ 64 224 „_ , 142 0 .: 0 0 " '0 1Ac1om 1.270' s, 35.56 34.77 0 0. ' 0 ., 0 0, 0- 0 0' 1A-clomd ; 1.270 • s 35:56 34.77 , 0 0 0 0. 0 0 .. 0 .0 1Dc2om 0.870 s 0.00' 0.00 , 0. ,, 0 0 0 0 0 1 D-c2om .- ... 0.870 ." s ... 0.00 ... _ 0.00 0 _. :.:.:. 0 0 . 0 : 0: 0 ' 0 0. 13A5ocs 0.125 sw 3.50 2.22 0 0 0 0 0 0 0 0 IW 1A-c1om_ 1.270 sw 70;95 0 0 0 0 0 0 0 0 _�--G V✓ ��--G _ 13A-5ocs , _ 0.125 _ w _ ,35.56 3.50 2.22 '. 0 - 0 0 '0 0 0 0 0 1A-cl om 1.270 w 35.56 91.12 0,°- 0 0 0 0 0 0 0 1 D-c2om .0.870 W 24.36 77.43 0. 0 0 _O 0, 0 0 0 W 13A-5ocs 0.125 nw 0.00 0.00 0 0 0 0 0 0 0 0 1Aclomd 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 P 12C-osw • . 0.091 - 2.59 1.28 ' 96 ,, ` 96 245 ° 123 ' : 80 , _- .80 - .. 204 , ., 103 C_ .. 166-19ad 0.049, 1.37 2.57 156 156 214 401 39 39 54 100 F , „ 21A-20c :. .. 0.027 _- - . .0.76 0.00 . -:156 156 _ '118, 0 '_ 39. - 39 ` :,, 29 0 6 c) AED e)cursion 85 -0 Envelope loss/gain 1806 2761 287 194 12 a) Infiltration 304 81 0 0 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 2109 2842 287 194 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 45 31 287 -194 14 Subtotal 2155 2873 0 0 15 Duct loads -0% O% 0 0 -0% 0% 0 0 Total room load 2155 2873 0 0 Air required (cfm) 1 183 1461 1 0 0 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wri htSOft" 2013-May-10 09:12:34 9 RightSuite® Universal 2012 12.0.07 RSU08101 Page 3 �� C:\Users\Quid(Calcs\Documents\Wrightson HVACINOBLE RES..rup Cale = MJ8 Front Door faces: N -- w►rightsoft, Right-JO Worksheet Job: AHU 1 Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL34946 Phone: 772-466.6799 Fax 772-466-6796 Email: QUICKCaLCS@PAL.COM 1 Room name KITCHEN BREAKFAST 2 Exposed wall 0 ft 22.6 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 169.5 ft 1.0 x 212.0 ft 5 Room area 169.5 ft2 212.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 ' WI 13A-bocs 0.125 ri 3.50 2M 0 0 .. 10 0 "- 0 0 .. 0 0 G, 1A_.1om. 1.270 n 3556 34.77 0 0. 0 0 0 .. 0 .0 6 VN 13A-0ocs 0.125 ne 0.00 0.00 0 0 0 0 0 0 0 0 t-G 1Aclom 1.270 ne 0.00 0.00 0 0 0 0 0 0 0_ 0 11 13A-bocs 0.125 a 3.50 2.22 0 0' 6' 0 0 0 0- 0 AA-clom 1.270 s. 35.56 91.12 0. 0 0 0 0. 0 0 0 11 DO - 0.390 a 10.92 ' 11.31 0 ... ` 0 - 0 - ,' 0 - 0 0 0 ' D WI 13A-0ocs 0.125 se 0.00 0.00 0 0 0 0 0 0 0 0 _ 1A-c1om- 1.270 se 0.00 0.00 0 0 0 0 0 0 0 13A-5ocs 0.125 s 3.50 2.22 ", .0 _ _0 .... 0 .D . 0 32: ' '17 - 60 , 38' 1A-clom 1.270 s `35.56 34.77 . 0 " 0 .', 0 0 15' ' ', , , 15 533 522 1Aclomd' 1.270 s M56 34:77. 0' : 0 0' 0, 0 0 0. , . 0 1D-c2om A:870 s 'Oi00 0.00 ,0 0. ' 0 0' 0 ' - 0 0 0 1D-c2om• _ .: 0.870 s " : -. 0.00 0.00 0 0 ..' . '0 0:, ." 0 _ 0 . - ; 0 0 �j 13A-5ocs 0.125 sw 3.50 2.22 0 0 0 0 45 31 107 68 G 1A-clom 1.270 sw 35.56 70.95 0 0 0 0 15 0 , 519 1035 13A-0ocs , 0.125 w 3.50'. 2.22 0 0 0 0 104 89 312, 198 -G 1A-clom 1.270 w 35:56 91.12 0 , ­0 _ 0 0 15 0 533 1367 G; 1 Dc2om 0.870 w 24.36 77.43 0 0• ^' 0 0 0 0 D 0 IIJ 13A-5ocs 0.125 nw 0.00 0.00 0 0 0 0 0 0 0 0 L-_G 1A-clomd 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 P ..:l kC Osw. , ° ', 0:091 . -,, ._.;2.55 ; ,, 1.28 0 . 0 . , 0 ' .' 0, 0 ' ',. 0 . O' 0'. C 16B-19ad 0.049 - 1.37 2.57 170 176 , 233 436 212 . , _ 212 - _ 291 545 , _ . 21A-20c- ..:.._ . .0.027 . - ` ' •. 0.76 .: 0.00 , . - - 170 _ 110 `. ; 128 O ; , , _ 212 212 - '•, . 160 . 0 6 c) AED excursion -150 586 Envelope loss/gain 361 286 2515 4359 12 a) Infiltration 0 0 328 88 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 2 460 Appliances/other 2400 0 Subtotal (lines 6 to 13) 361 3146 2842 4906 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 156 101 0 0 14 Subtotal 516 3248 2842 4906 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 Total room load 1 516 3248 1 2842 4906 Air required (cfm) 44 1651 241 250 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. AtL "F�' wrightSOtlt' RightSuite® Universal 2012 12.0.07 RSU08101 2013 May-10 0 Pag 34 AE75k C:\Users\Quick Calcs\Documents\Wrightsoft HVAC\NOBLE RES..rup Cale = MJ8 Front Door Faces: N wrightsoft, Right-JO Worksheet Job: AHU I Date: By: QUICK CALCS, INC. 317 ST LUC4E LN., FT. PIERCE, FL34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AC)L.COM 1 Room name FAMILYROOM HALLWAY 2 Exposed wall 19.0 ft 0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat1cool 4 Room dimensions 1.0 x 268.0 ft 14.0 x 3.0 ft 5 Room area 268.0 ft2 42-0 ft2 Ty Construction U-value Or HTM Area (W) Load Area (ft-) Load number (Btuhfftl-*F) (Btuh/ft2) or perimeter (ft) (13tuh) or perimeter (ft) (Btuh) Heat Cool Gross N/PIS Heat Cool Gross NIP/S Heat Cool 6 W� 1M4666i ­n:- 350 2220 -56 "'S6 Z 0 G- A461 ofn ,, 1 --0: ":0 0 F:O 01 -0 13A-5ocs 0.125 no 0.00 0.00 0 0 0 0 0 0 0 0 1A-clom 1.270 ne 0.00 0.00 0 0 0 0 0 0 0 O VV 1 A -.0cs -0.125 ` e- ".3 .50 2'M A ""0 '.0 -- - ---- -"0 - � 0 1A lom" 1.270 , 6 56 9l'u.:,' 0 0 0 �O 0 DO 7 .11" -:, -:�',",0.390 .a - .92, . � fo, 11.31 i- I r� �-O 0 0 w 13A-5ocs 0.125 se 0.00 0.00 0 0 0 0 0 0 0 0 " IA-.Iom 1270 se 000 000 0 0 0 0 0 0 0 0 '0 0 13A_50cs', 26 lig 251 0 a -3556 34 7 '"b 0 '0 0 IA-cloin 1 270 0 j "0 20 0 0 0 -L-L.-G 1270 35M, '3477 48 "48 11 D'62om '�'o 0 0, 0 O�870 -.s", 000 0.001:.. '0 0 0.", 0- 0 0 A 13A-5ocs 0.125 sw 3.50 2.22 0 0 0 0 '0 0 0 T-G 1A-clorn 1.270 sw 35.56 70.95 0 0 0 0 .0 -0 0 0 0 175 Ill - "0 -0 85.`56 0112 '1067 27,34 0 0 "0 Vy, 3.50 l-�� 1A-61om' 1270 W' 36 0 "0 6'870 :'w 24.36 777A3 �O 13A-5ocs 0.125 nw 0.00 0.00 0 0 0 0 0 0 0 0 Y-G 1A-clomd 1.2170. nw 0.00 0.00 0 0 0 01 0 .0. 0 0 0-09 Q 14 C 16B-1 gad 0.049 1.37 2.57 268 268 368 689 42 42 58 108 O'Y' O.QO -��42'.,-:A 268 2 6 c) AE D e)cursion 342 -11 Envelope loss/gain 35W 5585 375 240 12 a) Infiltration 275 74 0 0 b) Room ventilation 0 0. 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 3865, 5659 375 240 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 -375 240 14 Subtotal 3865 5659 0 0 15 Duct loads -0(/10 00/0 0 01 -00/. Ol/. 0 0 Total room load 1 1 3865 5659 0 0 Air required (cfm) 328 21381 01 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-May-10 09:12:34 -P1+ wrilghtSOfV Right -Suite@ Universal 2012 12.0.07 RSU08101 Page 5 14` CAUsers\QuIck Caics\Documents\Wdghtsoft HVAC\NOBLE RES.. rup Calc = MJ8 Front Door faces: N +- wrightsoft® Rig� ; ® Worksheet Job: A H Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@A )L.COM 1 Room name LAUNDRY CLOSET 2 2 Exposed wall 0 ft 1.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 9.0 x 6.0 ft 54.0 ftz 8.0 x 5.0 ft 40.0 ftz Ty Construction number U-value (Btuh/ftz-°F) Or HTM (Btuh/ftzj Area (ftz) or perimeter (ft) Load (8tuh) Area (ftz) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 13ASocs 0.125 'n 3.50 2.22 0 0 :` 0 0, 8: 8 28 18 11 L-G, 1A-c1 om 13A-rocs 1A-c1om . 13A-0o6s "IA-c1om 11D0 13A-Sots IA-clom 13A-06cs 1A-c1 om , 1Aclomd 1 D-c2orrr 1Dc2om. .. ; 13A-5ocs 4.270 0.125 1.270 0.125 1.270 0.390 0.125 1.270 0.125 1.270 '1.270 0.870 0.870 0.125 n ne ne a a a se se . s s 's s . -,s, sw 35:56 0.00 0.00 350 35:56 10.92, 0.00 0.00 3.50 35.56 36:56: . 0 00 0:00 3.50 34.77 0.00 0.00 2.22 • 91.12 11.31, 0.00 0.00 . 2.22 34.77 34.77 '0.00 :.: 000 2.22 ... 0 0 0 ' 0 0, 0- 0 0- 0,,. 6 0 0 0 0 : 0 0 0 `, 0" 0 0: 0 0 0 ' 0 0 0'' 0, 0 0 0 0 0 0 .0 0 0 -" 0 .; . 0 0' 0 .. 0 0 : 0 0 0 0_ 0 0 0 0 : 0. °- 0 0.. 0 0' 0 0 0 . _ 0 0 0 0 0 0 '•_0' 0' 0 0, 10 0 0 0 _ .0 0 0 0 6 0 0 0 , , '0 , 0 , `0 0 0 0 0 0 0 ,0 0 0 ;, 0 0 0 0. 0' 0 0'. 0 0 0' 0' 0 0 0 • 0 0 0 . 0 0 V�I -G W W W, L� t-G 1A-c1om 13A-0ocs IA-clom ,1D-c2orn 13A-5ocs 1Aclomd 12C-0sw' .. 1.270 0.125 1.270 0.870 0.125 1.270 0.091' sw w• w w' nw nw '. - 35.56 3.50 35.56 24.36 0.00 _ 0.00 2.55 . 70.95, 2:22 91.12 77.43 0.00 0.00 ' 1.28'' 0_ 0 0,. :' 0 0 0 0 0 0 0 0 0 0 ;:0 0 0 0 0 0 0 .. 0 0 0 0- 0 0 0 0 0 0 0:, 0' 0 0 p 0 0: 0 '. 0 0 . 0 .. 0:" 0 0 0 0 0 0 .: ' 0 0 6 0 0 0 0 ' :0', P C F 16B-19ad 21A ZOc 0.049 _. '0:027, - , 1.37 , .0,76 2.57 .O:pO 54 54 . - 54 :: 54 74 `, 41 139 0 - 40 `40 , 40 40 _ 55 ,., 30 103 0'. 61 c) AED wcursion -29 -6 Envelope loss/gain 1 115 1101 113 115 12 a) Infiltration 0 0 14 4 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 Appliances/other 0 0 500 0 0 0 Subtotal (lines 6 to 13) 115 610 128 119 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 198 127 0 0 14 Subtotal 313 737 128 119 15 Duct loads -00/0 0% 0 0 -0% 0% 0 0 Total room load 313 737 128 119 Air required (cfm) Z71 381 1 11 6 4 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. WPi ht50fft 2013-May-1009:12:34 f9 RightSuiteO Universal 2012 12.0.07 RSU08101 Page 6 �� C:\Users\Quick Calcs\Documents\Wrightsoft HVAC\NOBLE RES..rup Cale = MJ8 Front Door faces: N - wrightsoft® ANU - ® Worksheet Job: Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUIgCC4LCS@AOL.COM 1 Room name CLOSET BATH 3 2 Exposed wall 2.0 ft 28.9 ft 3 Room height 8.0 ft heat/cool 8.0 ft heattcool 4 Room dimensions 1.0 x 39.5 ft 1.0 x 78.5 ft 5 Room area 39.5 ft2 78.5 ft2 Ty Construction U-value Or HTM Area (W) Load Area (W) Load number (Btuh/ftmF) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NIP/S Heat Cool Gross NIP/S Heat Cool 6 `W1, 13A-5ocs 0.125 n 3.50 2.22 8 '8 28 18 80 -80 280 176 �---G 1A-clom 1.270 n ., 35.56 34.77 , 0 :" 0 . .. - 0 - 0 : .o 0 0 0 t-G 13A-0ocs 0.125 ne 0.00 0.00 0 0 0 0 0 0 0 0 1A-clom 1270 0.00 0.00 0 0 0 0 0 0 0 0 11 1IJ - 13A-5ocs 0125 -ne a ", 3.50 2.22 8 8 28 18 24 24 '84 53 1Aclom 1.270 a 35.56 91.12 0 0 0 0 0 0 0_- 0' L�_-Cp 1100 0.390 e e 10.92 11.31 0 0_ 0 0 0 0 0 0 W 13ASocs 0.125 se 0.00 0.00 0 0 0 0 0 0 0 0 E--G 1Aclom 1.270 se 0.00 0.00 0 0 0 0 0 0 0 0 13ASocs 0.125 : s 3.50 ' 2.22 0 0 ` , '0 . 0' 16 . 16 56 `, 36 IA-clom 1.270 s° 35.56 34.77 0 0 '.: 0 0 ' 0 0 0' •- 0 ,• 1A-clomd 1.270 s 35.56 34.77 0 „0 0, 0 0 0 0 0 1Dc2om 0.870 • s 0.00 0.00 0 0 0 0' i0 0: 0 0 1 D-c2om . .. 0:870 s .. 0.00 0.00 - 0 . 0 0 : , .. 0 0 0 ,,' , . 0 0 W _ 13A-5ocs 0.125 sw 3.50 _. 2.22 0 0 0 0 0 0 0 0 1A-clom 1.270 sw 35.56 70.95 0 0 ` 0 0 0 0 0 0 13A-0ocs' 0.125 w 3.50 2.22 • 0 0 .0 0 112 106 371 236 1Ac16m 1.270 w 35.56 91.12 0 0- 0 0 0 0 0' 0 1Dc2om. ' 0.870 w 124.36 .77.43. 0 ., 0 0 '0 6- 0 146 , '465 VV 13A-5ocs 0.125 nw 0.00 0,00 0 0 0 0 0 0 0 0 L-G 1A-c1omd 1.270 nw 0.00 0.00 0 0 0 0 0 0_ 0 0 P 12(j-0sw_ .. 0.091 - 2.65 1.28 , 0 ., 0 0 0. .. i0 0 0 = 0 C. 16-B-19ad 0.049 . - 1.37 2.57 40 40 54 102 79 79 " . , 108 202 F. ::21A-20c -. - - 0.027 .- 0.10 -0.00'- • 40' : ' 40 30' 0,' , 79' 79 _ 59 - O' 6 c)AEDex:ursion -7 157 Envelope loss/gain 140 131 1104 1326 12 a) Infiltration 29 8 419 112 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 169 13B 1524 1438 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 169 138 1524 1438 15 Duct loads -00/0 00/0 0 0 -0% 0% 0 0 Total room load ad 169 138 1524 1438 Air required 14 7 1291 73 Y Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -�+ wrightsoft' RlghtSuite® Universal 2012 12.0.07 RSU08101 2013 May-10 0 Page 77 AF63` CAUsers\Quick CaicMDocuments\Wrightsoft HVAC\NOBLE RES..rup Cale = MJ8 Front Door faces: N - wrightsoft° Riah -J® Worksheet Job: A hhll Date: By: QUICK CALCS, INC. 317 ST. LUGE LN., FT. PIERCE, FL34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BEDROOM 4 BEDROOM 3 2 3 4 5 Exposed wall Room height Room dimensions Room area 18.0 ft 8.0 ft heat/cool 1.0 x 142.0 ft 142.0 ftZ 18.0 ft 8.0 ft heat/cool 12.0 x 13.0 ft 156.0 ftZ Ty Construction number U-value (Btuh/ftZ--°F) Or HTM (Btuh/ft2) Area (ftZ) or perimeter (ft) Load (Btuh) Area (ftZ) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 WI � �-G VN G Val- 1G L D' 13A5ocs 1A-.1om _ 13A-5ocs IA-clom 13A-5ocs 1Aclom 11 D0 13A5ocs 1A-c1om 13ASoos 1Aclom 1A-clomd . 1 D-c2om 1 D-c2om . 13A-5ocs 1A-c1om 13A-5ocs 1A-c1om 1 D-c2om 13A-5ocs 1A-clomd 12C-0sw 0.125 1.270 0.125 1.270 0.125 1.270 0.390 0.125 1.270 0.125 1.270 1.270 0.876 0.870 0.125 1.270 0.125 1.270 0.870 0.125 1.270 0.091 n n ne ne a a a se se s s s s s sw sw w w w my nw - 3.50 35.56 0.00 0.00 3.50 35:56 10.92 0.00 0.00. 3.50 35.56 35.66 0.00 0.00 3.50 35.56 3.50 35.56 24.36 0.00 0.00 2.55 2.22 34.77 0.00 0.00 2.22 91.12 11.31 0.00 0.00 2.22 34.77 34.77 0.00 0.00 2.22 70.95 2.22 91.12 77.43 0.00 , 0.00 1.28 104 15 0 0 0 0 0 0 0 16 0 0 0 0 0 0_ 24 0 0 0 0 0 .89 0 0 0 0 0 0 0 0 16 0 0 0 0 0 0 24 01 0 0 0 0 312 533, 0 0 0 0 0: 0 0 56 0 0 0 0 0 0 84 0'. 0 0 0 0 198 522 0 0 0 0 0 0 0 36 0 0 0 0 0 0 53 0 0 0 0 0 104 15 0 0 32 0' 0 0 0_ 0 0 0 0 0 0 0 8 0 0 0 0 64 89 0 0 0 32, 0 0 0 0 0 0 0' 0 0 0 0 8 :0 0 0 0 64 312 533 0 0 112 0- 0 0 0 0 0 0 0 0 0 0 28 0 0 0 0 163 198 522 0 0 71 0 0 0 0 0 0 0 0 0 0 0 18 0 _0 0 0 82 WI L-G W -G �--G W r G P C F .. 16B-19ad 21A-20c 0.049 0.027 - - 1.37 0.76 2.57 0.00 142 , 142' 142 142 195 107 365 0 156 156 166 `. 156 214 118 401 0 6 c)AEDexwrsion -67 S2 Envelope loss/gain 1287 1107 1480 1230 12 a) Infiltration b) Room ventilation 260 0 70 0 260 0 70 0 13 Internal gains: Occupants @ 230 Appliances/other 1 230 0 0 0 0 Subtotal (lines 6 to 13) 1547 1407 1740 1300 Less extemal load Less transfer 0 0 0 0 0 0 0 0 14 15 Redistribution Subtotal Duct loads -0% 0% 0 1547 0 0 1407 0 -0% 0% 66 1806 0 42 1342 0 Total room load Air required (cfm) 1547 1 131 1407 721 1 1806 153 1342 68 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -FkWri htSOft' 2013-May-1009:12:34 L 9 RightSufte® Universal 2012 12.0.07 RSU08101 Page 8 ACCA CAUsers\Quick Calcs\Documents\Wrightsoft HVAC\NOBLE RES..rup Calc = MJ8 Front Door faces: N - - wrightsoft, Rigght-J® Worksheet Job: AX 2 Date: QUICK CALCS, INC. By. 317 ST. LUGE LN., FT. PIERCE, FL34946 Phone: 772-466-6799 Fax 772466.6796 Email: QUIGCCALCS@AOL.COM 1 Room name AHU 2 MASTER BEDROOM 2 Exposed wall 88.8 ft 34.4 ft, 3 Room height 8.0 ft d 8.0 ft heat/cool 4 5 Room dimensions Room area 603.5 ft2 1.0 x 226.0 ft 225.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft;°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WI 73A 6ocs . 0125 n °' 3 50 2.22 56 56 196 125 0 0 1Ac1om..,._... n;: 0:00 ,.. 0 _ 0 ;• 0 0 :0 `. . _0 ,. ,0 VN 13A-5ocs 0125 no 3.50 2.22 34 19 68 43 0 0 0 0 r-C 1Ao1om. 1 270 ne 35.56 70.43 15 0 519 1027 0 0 0 0 11 Wi _ 13A 5ocs-r 0125 e.`_ 350 2.22 72 52 182 116 0 0 0 0 1Ac1om 9 270 a 35.56 9L12 2' 0 711 1822 0 0 0 0 11D0 , ;.. ... _... . ':.0890 .e.: , ._..0.00 . ,' 0,00 ..Y. 0 . 0 .- ... 0 .':' . , O c.. R:... 0 0 .. °: '0 _ 13ASoos 0.125 se 3.50 2.22 34 19 68 43 0 0 0 0 1Aciom.._ 1,270 35.56 70.95 15 0 519 1035._ 0 0 0 0 __. 13A 5ocs : 0125 ,se s - 3.50 2.22 364 336 > 1176 _ 748 = 144 114 399 254 1Ac1om 1' 270 s ~' 35:56 34.77 30 ° 3D 1067 ` 1043 v 30 30 1067 1043 1A clamd. 1.270 „s' 0:00 0:00 0 0 0 ` 0 . 0 ' '"U 0 0 1D c2om 0.870 .s'. • 24:36 27,10 .6 A 6 146 " 163 0' . `0 0 0 1Dc2om":., . _, -' ;;.0 870 s;' .:,,2436 _' 27.10 ,.. >12 :-.12 _ 292 . ,.' , .325 .;_ ... ".,0 .... _, _0 ... °"0 _ 0. W 13A-0ocs 0.125 sw 0.00 0.00 0 0 0 0 0 0 0 0 1Ac1 om 1 270 sw 0.00 0. 00 0 0 0 0 0 0 0 0 ,_ 13A�ocs : 0125 _ w 3.50 2 22 64 64 224 142 ,_ 64 64 224 942 G 1Ac1om 4270 w', D:00 0,00 0 0 0 0 "� 0 0 6 0` u---G: Dc2om ° ` :.0 870 w 0.� .0.00 ; 0 , ,.< . 0 0 0 0 V�I 13A-5ocs 0.125 nw 3.50 2,22 68 28 97 62 68 28 97 62 Y--G 1Aciomd. 1.270 nw, 35.56 70.43 40 0 2834, 40 0 1431 2834 P.... ; - 12C Osw;,,' _ 0 091 • '..- . _ 0:00 ", 0.00 , .. 0 '•_ .0 .1431 ,.:... . 0 : ',. 0 _ - 0 `. ... ; ,... ,0 C 0.049 - 1.37 2.57 6D4 604 828 1553 226 226 310 581_ ._._ F„ .16B-19ad _ _...". 20c -;.'.. _ 0 027 - := ... ..`0.76 _ 0 00 ,• ;;604 ,'.:604 , ._„- C, ' :456 .,_ ,. 0 r;- ..;22ti ... - ; _ ., 226 , •, , .'.;171 0. r .F j�- 6 a)AEDex:ursion 0 94 Envelope loss/gain 7979 11079 3698 5010 12 a) Infiltration 1286 345 499 134 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 9265 11424 4197 5143 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 9285 11424 4197 5143 15 Duct loads 00/0 00/0 0 0 -0% 0°h 0 0 Total mom load 9265 11424 1 4197 5143 Air required (cfm) 633 633 287 285 16 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrilghtsofr Right -Suite® Universal 2012 12.0.07 RSU08101 2013 May-10 09:Page 9 ��` C:\Users\Quidc CalcslDocumentslWrightsoft HVAC\NOBLE RES..rup Cale = Mes:J8 Front Door facN - wrightsoft, ARU 2 ® Worksheet Job: Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL34946 Phone: 772-466.6799 Fax 772-466.6796 Email: QUICI(CALCS@AOL.COM 1 Room name WIC WIC 2 2 Exposed wall 6.0 ft 0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 6.0 x 6.0 ft 1.0 x 31.5 ft 5 Room area 36.0 ft2 31.5 ftz Ty Construction U-value Or HTM Area (ft2) Load Area Load number (Btuh/ft;°F) (Btuh/ft) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WI 13A-0ocs 0.125 n 3.50 2.22 0 0 0 0 0 0 0 0 L-G IA-clom 1.270 n 0.00 om 0 0 0 0 0 0 0 0 yJ 13A-0ocs 0.125 no 3.50 2.22 0 0 0 0 0 0 0 0 -G 1Aclom 1.270 ne 35.56 _ 70.43 0 0 0 0 0 0 0 0 11 ViV 13A 50cs Q 125 a 3.50, 2.22 0 0 0 0 0 0 0 0 �l-_-Gp 1A-c1om 1.270 a 35.56 91.12 0 0 0 0 0' 0 0 0 11D0 0.390 a 0,00 0.00 0 0 0' 0' -0 • 0 0 0 W, 13ASocs 0.125 se 3.50 2.22 0 0 0 0 0 0 0 0 �--G 1A-c1om 1.270 se 35.56 70.95 0 0 0 0 0 0 0 0 0.125 s 3.50 2.22 48 48 168 107 0 0 0 0 IA-clom 1.270 s 35.56, 34.77 0 0 0, 0 0 0 0 0 Ti13A5acs. 1A-clomd 1.270 s 0.00 000 0 0 0 0 0 0 0 0 1 Dc2om 0.870 s 24.36 27.10 0 0 0 0 0 0 0 0 1Dc2om. 0.870 s 24.36 27.10 0 0 0 0 0 0 0 0 VV _„ 13A-5ocs 0.125 sw 0.00 0.00 0 0 0 0 0 0 0 0 l-G IA-clom 1.270 sw 0.00 0.00 0 0 0 0_ 0 0 0 0 13A-6ocs 0.125 w 3.50 2.22 0 0 0 0 0 0 0 0 1Ao1om 1.270 w 0.00 0:00 0 0 0 0 0 0 0 0 1 D-c2om ' 0.870 w 0.00 -0.00 0 0 0 0 0 0 0 0 W 13A-5ocs 0.125 nw 3.50 2.22 0 0 0 0 0 0 0 0 0 0 0 0 0 P 1Aclomd 12C-0sw 1.270 0.091 nw - 35.56 0,00 70.43 0.00 0 0 0 0 0 0 0 0 0 0 0 C 1613-19ad 0.049 - 1.37 2.57 36 36 49 93 32 32 43 81 F .21A-20c 0.027 -- 0.76 0.00 36 : 5 27 0 32 32 : 24 0 6 c)AEDex:ursion -22 -8 Envelope loss/gain 1 245 178 67 73 12 a) Infiltration 87 23 0 0 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 331 201 67 73 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 331 201 67 73 15 Duct loads -0% 00/0 0 0 -0% 0-/01 0 0 Total room load 331 201 67 73 Air required (cfm) 23 11 5 4 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. WI't htsoft' 2013-May-1009:12:34 9 RightSuite® Universal 2012 12.0.07 RSUD8101 Page 10 �� C:\Users\Quick Calks\Documents\Wrightsoft HVAC\NOBLE RES..rup Cale = MJ8 Front Door faces: N - 1- wrightsoW , Righ - ® Worksheet Job: A H Date: By: QUICK CALCS, INC. 317 ST. LUGE LN., FT. PIERCE, FL34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKC4LCS@A )L.COM 1 Room name MASTER BATH STUDY 2 Exposed wall 16.9 ft 31.4 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 158.0 ft 1.0 x 162.0 ft 5 Room area 158.0 ftz 152.0 ft2 Ty Construction U-value Or HTM Area (ft) Load Area (ft) Load number (Stuh/ftx-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 13A:5ocs 0.125 n 3.50 2.22 0 0 0 0 56 56 196 125 L-G 1A,1om 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 W 13A-5ocs 0.125 ne 3.50 2.22 0 0 0 0 34 19 68 43 � C 1A-clom 1.270 ne 35.56 70.43 0 0 0 0 15 0 519 1027 11 Val 13A-0ocs 0.125 a 3.50 2.22 24 24 84 53 48 28 98 62 { 1A-c1om 1.270 a 35.56 61.12 0. 0 0 0 20 0 • 711 1822 :- S 11 D0 0.390 a 0.00 0.00 0 0 0 0 0 0 0 0 WI 13A-5ocs 0.125 se 3.50 2.22 0 0 0 0 34 19 68 43 - ---G 1Ac1om 1.270 se 35.56 70.95 0 0 0 0 15 0 519 1035 13A-5ocs 0.125 s 3.50 Z22 112 94 329 209 80 80 280 178 1A-clom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 IA-c1omd 1.270 s 0.00 0:00 0 0 0 0 0 0 0 0 1 D-c2om 0.870 s 24.36 27.10 6. 6 146 163 0 0 0 0 1D-c2om, 0.870 s 24.36 27.10 12 12 292 325 0 _ 0 0 0 W _ 13A-5ocs 0.125 sw 0.00 0.00 0 0 0 0 0 0 0 0 L-G 1A-c1om 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 13A-6ocs 0.126 w 3.50 2.22 0 0 0 0 0 0 0 0 1A-clom 1.270' w 0.00 -0.00 0 0 0 0 0 0 0 0 �G 1 Dc2om 0.870 w 0.00 0.00 0 0 0 iO 0 0 0 0 W 13A-5ocs 0.125 nw 3.50 2.22 0 0 0 0 0 0 0 0 L--G 1Ao1omd 1.270 nw 35.56 70.43 0 0 0 0 0 0 0 0 P 12C-0sw 0.091 - 0.00 0.00 .0 0 0 0 0 0 0 0. C 1613-19ad 0.049 - 1.37 15B 158 _ 217 406 152 152 209 391 •F 21A-20.c 0.027 - 0.76 _2.57 0.00 ,. 158 158 , 119 0 152 152 115 0 6 c)AEDex:ursion -120 55 Envelope loss/gain 1188 1037 2781 4781 12 a) Infiltration 246 66 455 122 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 1434 1103 3237 4903 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1434 1103 3237 4903 15 Duct loads -00/0 0% 0 0 -0% 0% 0 0 Total room load 1434 1 1103 3237 4903 Air required (cfm) 98 61 221 272 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. _ Wtt i ht50Tt' 2013-May-10 09:12:34 9 Right -Suite® Universal 2012 12.0.07 RSU08101 Page 11 ACC>- C:\Users\Quid(Calcs\Documents\Wdghtsoft HVAC\NOBLE RES..rup Cale = MJ8 Front Door faces: N i OFFICE USE ONLY: I p, DA'£E FILED: 3 3 PERMIT # 1 P 0 E O REVISION FEE: V50.0 rj RECEIPT # �- PLANNING & DEVELOP T G BUILDING & CODE REGU O 2300 VIRGINIA A FORT PIERCE, FL (772) 462-15 APPLICATION FOR BUILD IT ; PROJECT INFO 1. LOCATION/SITE SION ADDRESS: 170 dV 3 7 5t . 'P erce llc�4- 3 y 9 r 7 `,'rV. jS -- . 2. DETAILED DESCRIPTION OF PROJECT REVISIONS:L�-- 3. CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: ST. LUCIE COUNTY CERT. #: BUSINESS NAME: QUALIFIERS NAME: ADDRESS: CITY: STATE: ZIP: PHONE (DAYTIME): FAX: OWNERBUILDER INFORMATION: NAME: n� ✓Va&- ADDRESS: 13051- All 1-3 5-1 CITY: F:�. P" C/'C F STATE: ZIP: PHONE: (770 ZI6 - 2-7 83 FAX: ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: PHONE (DAYTIME): SLCCC: 9/23/09 Revised 04/26/2010 STATE: FAX: ZIP: Florida Building Code Online 4 s Page 1 of 2 A Product Approval Menu > Product or Application Search > Application List > Application History > Application Detail ". FL # FL14569-R2 Application Type Affirmation Code Version 2010 Application Stas Approved - P Comments Status .i � ;; ,�, °` =- � V Archived aE Co Product Man facturer JELD-WEN I Address/Phone/Email, r ' 3737 Lakeport Blvd Klamath Falls, OR 97601 (800) 535-3936 fbc@jeld-wen.com Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Certification Agency Validated By Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Janet Gerard fbc@jeld-wen.com JELD-WEN Corporate Customer Service 3737 Lakeport Blvd. Klamath Falls, OR 97601 (800)535-3936 customerserviceagents@jeld-wen.com Exterior Doors Swinging Exterior Door Assemblies Certification Mark or Listing National Accreditation & Management In., National Accreditation & Management In; Standard TAS 201 TAS 202 TAS 203 /U ST LUC19 COUNTY BUILDING DIVISION REVIEWED FOR C IAN1C@ REVIEWED BY DATE PLANS AND PERMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE http://www.floridabuilding. org/pr/pr_app_dtl.aspx?param=wGEV... 3/6/2013 Florida Building Code Online Page 2 of 2 isI affirm that there are no changes in tt Code which affect my product(s) and my compliance with the new Florida Building Documentation from approved Evaluation or Validation Entity i Yes �::, No „N/A Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved FL14569 R2 COC SA14569 signed and Method 1 Option A 12/16/2011 12/16/2011 12/18/2011 Summary of Products FL # ii���Model, Number or Name Description 14569.1 Steel Wood Edge Door 6-0" x 6'-8" , Full Lite, Single or Dout Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL14569 R2 C CAC NI006255-R4.P Approved for use outside HVHZ: Yes Quality Assurance Contract Expira Impact Resistant: Yes 09/30/2013 Design Pressure: +60/-60 Installation Instructions Other: Product must be installed per manufacturer FL14569 R2 II 3W0509-03.PDF instructions as stated on drawing 3WO50903 Verified By: National Accreditation & Created by Independent Third Party: Evaluation Reports FL14569 R2 AE PER 1398 6-13-11.t Created by Independent Third Party: Back Next Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Copyright 2007-2010 State of Florida.:: Privacy Statement :: Accessil Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any 850,487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed and provide the Department with an email address If they have one. The emails provided may be used for official commi However email addresses are public record. If you do not wish to supply a personal address, please provide the Depar which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., pl. Product Approval Accepts: ®® Cre t aar E http : //www. floridabuilding. org/pr/pr_app_dtl. aspx?param=wGEV ... 3/6/2013 N NOTICE OF PRODUCT CERTIFICATION CERTIFICATION NO: DATE: CERTIFICATION PROGRAM: COMPANY: CODE: REVISION DATE: NI006255-R4 IQ/ 14/2005 Structural JELD-WEN J-104-3 06/08/2011 The "Notice of Product Certification" is valid only when Administrator's Seal is applied to the upper left hand portion of this form and a certification label is applied to the product. This certification seal represents product conformity to the applicable specification and that all certification criteria has been satisfied. The product described below is approved for listing in the Directory of Certified Products at www.NAMICertification.com, Please review, and advise NAMI immediately if data, as shown, requires corrections. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION JELD-WEN Exterior Doors JELD-WEN's "Steel Wood -Edge" Double 3737 Lakeport Boulevard In-Swing/Out-Swing Entry Doors Klamath Falls, OR 97601 w/ODL Impact Glass or ODL Allen Frame and Endura Ultimate Hurricane Astragal Configuration:XX Glazing: IG-0.125" Temptered Glass/ Laminate- 0.125" Annealed Glass/ 0.090" PVB by Solutia/ 0.125" Annealed Glass Frame: W- 62" Panel: W- 31" DLO: W- 1'l0" H- 611" H- 617" H- 5'4" " SPECIFICATION PRODUCT RATING TAS 201/202/203-94 Design Pressure: +60/-60 psf Large Missile Impact Rated Product Tested By: National Certitied Testing Laboratones Report No: NCTL-210-3195-1 (Structural/ Impact)/ NCTL-SJW2011-070 Expiration Date: September 30, 2013 Administrator's Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway Hayes, VA 23072 TEL: (804) 684-5124/ FAX: (804) 684-5122 JFI-DIVENg Steel WOOD EDGE IMPACT GLAZED STEEL DOOR 6-8 OUTSWING SINGLE OR DOUBLE DOOR UNIT UTILIZING COMPONENTS FROM OOL' INC. AND ENDURA PRODUCTS INC. GENERAL NOTES 1. THIS PRODUCT IS DESIGNED TO COMPLY WITH THE CURRENT FLORIDA BUILDING CODE (FBC) BASE ON THE SIGNED AND SEALED DATE: INCLUDING HVHZ AND HAS BEEN EVALUATED INACCORDANOE WITH THE FOLLOWING: TAS201A1 ASTME330-02 ASTM E1666-05 TAS 202-9a ASTM E33t-D3 ASTM E1996-OS TAS 203-9a ASTLIE28I-91 2. WOOD BUCKS BY OTHERS.MUSTBE ANCHORED PROPERLY TO TRANSFER LOADS TO THE STRUCTURE. 3. PRODUCTANCHORS SHALL REASLISTEDANOSPACEDAS SHOWNON DETAILS. ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. 4. DESIGNED PRESSURE RATING SEE TABLE J. PAGE I. 5. THIS PRODUCT MEETS THE WATER REQUIREMENTS FOR HIGH VELOCITY HURRICANE ZONE (HVIO 6. PRODUCT DOES NOT REOUIRESHUTrERS RESIDENTIAL INSUTATED STEEL DOOR (Common to all frame conditions) DOOR LEAF CONSTRUCTION: Face sheets: 24 GA (0.021"min) thickness. Galvanized steelA-525 commercial quality AKDO perASTM 620 with average minimum yield strength Fy(ave)-30627pst. Core Design: Expanded polystyrene w`th 1.0 to 1.25lbs density, by Jeld-Wen Inc. Panel Construction: The active and inactive panels are constructed from 24 GA to.021- min) galvanized sleet The face sheets at top and bottom are bent 9D' over the' top and bottom rails. The top rail measures 1.D- high x 1.888' wide. The steef bottom rail measures 1.21' high x I ZM' wide. The sides of the face sheets are roll formed into the latch and lunge sfiles which measure 1.00-high x 1.686- wide. The inferior tawny is frlted with expanded polystyrene. The fats sheets are glued to the expanded polystyreno. The panels are cut out for the two-piece ODL Aluminum ALLEN frame. Units are glazed with tembered and laminaled impact 1' IG. On double door applications the inactive door is fitted with an extruded aluminum astragal of 6063-T5 alloy, manufactured by Endure. Frame Construction: The frames are constructed of fingerjoinfed pine ��'a�mbs measuring 4.8116'x 1-114'. The headjambs are mortised and buttlomiW58 7 the side jambs, and attached with three (3).16GA 7,'16' crown x 2" ton�pr��,, staples on each side. The threshhold is attached to the side jambs IYitrl a �" three (3) 160A 7116 ' crown x 2' long. staples on each side. Glazing: ODL insulated lite is 1- overall thickness, consisting of one (T pane of 0.125- tempered glass; 0.5- airspace; two (2) panes of 0.12 annealed with .090' PVB intedayer by Salutfa. All fires are sarlmviche glazed into the panels. 37 1/2` MAX. FRAME WIDTH 35 3/4` MAX. PANEL WIDTH �I o � 9 20 1/2_ � ai = MAX O = 16 D.L.O. w a �5EE5 15 0 3 3 / 4 n B 4 / � o � m I SINGLE OUTSWING UNIT (X) SCALE.- 1/2" =1'-O" _ 74" MAX. OVERALL FRAME WIDTH. 36 1 /2" MAX. PANEL WIDTH W/ASTRAGAL 20 1/2 20 1/2' x MAX MAX' Ci j" W D.LO. INACTIVE ACTIVE 00 a AID 3 v1 E C Zt n REF ASTRAGAL BOLT ITEM # 12 TABLE i DESIGN PRESSURE RATING APPROVED FOR USE WHERE PROTECTION FOR WATER INFILTRATIaN IS REWIRED POSrtwE 40.OFSF NEGATIVE - .0 PSF SHEET 9 TABLE OF CONTENTS DOUBLE OUTSWING UNIT (XXl SCALE. 1/x" =1'-0" Digitally signed by AIeX SPyrou Reason: I am approving this document Date. 2011.10.07 09:01:48 - 04i00' NOTES: 1 — ALL VIEWS FROM EXTERIOR. 2 - FOR HORIZONTAL. ANCHOR IN 1 X BUCK OPTION IN MASONRY/CONCRETE: SEE SHEET 4 FOR'DETAILS. 3 — FOR Tr- TL,OALTIANQ`�.OR IN 1X BUCK OPTION IN 1/ASoT1�C(ST�]T�fG. SEE SHEET 4 FOR DETAILS. ALEXIS SMOU FLORIOA PE. NO.4B101 CENTWORKS. LLO. 127 W. FAINBANKS AVE. STE. 418 WINTER PARK, FL 32M FBPE CENT. Of AUNT. NO.25520 Certification No.: N/ _ Il v, Reviewed By: Date Wewed— rn nCD O m o M N O Z m N O r =OWE r 00 OJ m1Ah u_ p� L m r x �M aali E Y i JW0509-03 i M 1 /4" MAX. SHIM THK. 1 1/2- MIN. EMB. SEE DETAIL A SHT. 7 T1 1 5 1 1/2" MIN. EMB. z IPAot '■■I� ��� SEE 1 DETAIL G I� 1 2322 ® I' 14 co AL RI x " I t I 4 It Ii trt ►� 21 �i�_: 30 28 1 Item DESCRIPTION Material I SIDE JAMS 1 1 4 x 4 9 16 FINGERJOINTED PINE PINE 2 HFAO JAMB 11 4 x 4 9 16 ING FERJOI,YTED PINEPINE S- p! x 4 BUTT HINGE 12GA .089 - MIN) 4 ig x 1' PHILLIPS FLATHEADWOOD SCREW STEEL 5 10 PHILLIP' HD SCREW WITH 112 MIH. EMBED- STEEL 6 f0 X 2' PMLUPS FIAIMW WOOD SCREW STEEL 7 8 X 3 PHU-UPS FLAILHEAD WOOD SCREW STEEL 8 8X1 PHILLIPS FLAT HEAD WOOD SCREW STEEL 9 COMPRESSION WFATHERSTRIP 0-LON ODS-650 VINYL I1 OUTSWING THRESHOLD ENDURA ALUMINUM 12 ASTRNGAL THROW BOLT STEEL ROD 5 16 r I8' STEEL 13 ASTRAGAL BOLT STRIKE PLATE LOCATED ON HEAD JAMB STEEL 14 116 Gm 7 16 CRONN : 2 LONG STAPLES STEEL 15 KWIKSET LOCK SERIES 400 STEEL 16 KWIKSET DEADBOLT SERIES 780 STEEL 17 ENDURA ULTIMATE HURRICANE ASTRAGAL ALUMINUM 7 ASTRAGAL BOLT STRIKE PLAIT ON BOTTOM SILL 19 2x WOOD BUCK WOOD 2 NON COMPRESSION SHIM WOOD 21 DOW 995 SILICONE SEALANT SILICONE 22 1 IMPACT IG ASSEMBLY BY ODL GLASS 23 1 8 TEMPERED GLASS CLASS 24 3 8 LAMINATED ANNEALED GLASS GLASS 25 LOCI( BLOCK SOLID WOOD x 12 LC RODD 25 TOP RAIL LVL LVL 2 BOTTOM RAILr2sGA MIN GALVANIZED STE S L 28 FXPAMU POLYSTYBEFE 1.0 W I-nft DUM BY JE1D-M FOAM 29 STEEL DOOR PANEL SKIN MATERIAL 24CJL G41.VANIZED A-525 COMMER(YAL GUAUfY 0-021' I M. MICK. STEEL GALVANIZED 30 FBA4 ALU AL,AIddJM 31 LK 32 FWGFR LVL 33 8 x 2 PHILLIPS FLATHEAD WOOD SCREW STEEL 34 3 16 IIW BWLDEX TAPCON WITH 1.25- MIN. EMBEDMENT STEEL 35 OPTIONAL ix WOOD BUCK WOOD 1" MIN. T 1' MIN. 3 g V SCALE. 6" =J'-0" 2 CONCRETE INSTALLATION SCALE. 6" =J'-0" NOTES: FOR TAPCON MASONRY AND WOOD SCREW ANCHOR SPACING (ITEMS J5 & #34), SEE' SHEET 5. FOR VERTICAL ANCHOR IN IX BUCK OPTION IN MASONRY/CONCRETE. SEE SHEET 4 FOR DETAILS. OPTIONALLY, ANCHOR CAN BE PLACED IN NARROW SECTION OF HEAD OR JAMB AS LONG AS MINIMUM EMBEDMENT IS ACHIEVED. •`%t kSsp y"'t . No 0 •rn v O o OaD Otc9 N G ci mo o m n MOM= 0 ► m_�'q O� My n lGntt i `r- M E co ]C QQ N3 15 Z F Oco j O umo yC fop VI~q W M W Ng WpZ J UO O�� WIC N. 3 In 1 cc � t. * s--ANOTED i • on. Br:: EAG RORID� REPNO. Uim CHK. BY.S. SAFFE DRAWING NO.: L10•' �j��` CERTW0RK9.LLC. JW0509-03 1I) W. FARBANKS AVE. STE aT8 SHEET 2 CF 7 OF u,uT� AAUURLL NNOMm F.vE — Certification k: Reviewed By: 1 1/2- a 3 5 WIN. �rI/SHIMS SEE DETAIL 1• SHEET 7 MIN. 6 A 3 WOOD INSTALLATION (SCALE.- 6" mil'-O" J 6 a 34 1 1/4• WIN. EMB. 1 �1/4• MAX. 1• SHIM MIN. 1- SEE DETAL A 2B MIN.�T 7 15 rn... -- ---- 6. ,/4• MA% ,MIN. 5 3 n ?AA 22SEE DETAIL 1- MIN. SEE TAIL G SHT. 6 30 21 21 n d g 31 I MIN 6 B 8 ,MOOD INSTALLATION (SCALE` 6' =1'-O' 1 1/4• 80 MIN. EMB. I Z� W 1- J O 1 4• MAX. 1 /SHIM ,• 1-O:3 U SEE DETAIL A 22 SHFET 7 MIN. 1• I MIN. Q m w LA D 51iT. 6 JO 21 n� 31 O cj 000 In } U 21 W O tq •�,Y •f i. �V :} f4._.^.:i{� :`.. T. �i.♦ -_ Imo.' �j K _ EISAF 8 (SCALE.` 6- >1'—O') 1J 6 6 3 CONCRETE INSTALLATION SCALfi 6" =f'—o~J NOTES: E> ASTAGIC FASTENER SPACING DETAIL F. SHEET 6. (TOTAL OF 14 SCREWS). LATCH AND DEADBOLT STRIKE PLATES MOUNT To ASTRAGAL WITH ABLE NUT PLATE S UPH1iUP5 BOTH PLATES REQUIRE (8 X 3 FIAT MEW WOOD SCREWS. 2. BUCK TO SUBSTRATE FASTENING MAY UTILIZE OPTIONAL 3/16• TTW BUILOEX TAPCON. E> FOR TAPCON MASONRY AND WOOD SCREW ANCHOR SPACING (RDNS /5 AI /J4), SEE SHEET 5. MACTNE FOR HORIZONTAL ANCHOR IN 1X BUCK OPTION IN MASONRY/CONCRETE. SEE SHEET 4 FOR 5 DETAILS. ttillllll", OPTIONALLY ANCHOR C ry I Ow' SECTION OF NERD OR JAMB AS LONG rR AS UN�W14 EMHEOMET�iJS�SAa 1 :mot ac•J DC NzT*, OF : LU ` ALEYISSPY"W �/ ` AP.E NM 60101 FLOi iO •A`�iD.i•it \ Q • G\ �, CERTIYORKS,LLG \ iZT W. FASRSANAS AVE. STE AM WINTER OIVALE�t\t FL ECEM.P AMftK. Na t FBPE CENT.OF ALNTL NQ t66M n Addendu 1 lo� Cef6fication NO.: 1 O D S-12 v RWe,l.'ed gy- r;: ,--- - G BY NOTE s MrYS. MMM NO_ JW0509 EET 3 OF % 1 34 1 1/4- MIN. EMB. 1' MIN. ," MIN. I _ 1/4- MAX. m 1' MIN, 1' MIN. t' r SHIM MIN. 1• SEE DETAIL A 28 29 •0 > m rn C O D MIN. SHEET 7 15 O m I?1+ 2 y N O m Q 21SEE • a•Omco i d I 9 23 DETAIL SHT. 6 35 I � O -� m In In 1 � MIN. � .�s r :� . 1I�S73 C � tl �' x 1 4- MAX. 20 MIN. ::?.'<'ti"f'ii:• X r a m SHIM THK. + r %'i�i:; �E�Y ' LL l J ... { ,a SEE EXTERIOR Y DETAIL A925 SHT. 7 26 21 24 B 28 2 O OPERATING UN? 1X BUCR 35 32 1 34 9 l�:.t:.._.. 9 OPTION IN YASONRY/BVNCRETE 20 1 1/4- o O- z 30 _ 21 (SCAL&• 6• =1'-O") 1 1/4' NNW. ENB. _f 111WNN��� 3 Z� _ 1 SHIM - ,- Qf2� JfUW/1 27 21 a',✓ SEE DETAIL A MIN. 0 _.$ 22 SHEET 7 1• U O SEE MIN. p_ Z0 SEE DETAIL G 27 J0 z 9 ' ? �.pU = O DETAIL EXTERIOR f; SHT. fi J o SHT.23 a �}C�� \ 31 I f W p J FCc oo0 Y az R a ... ». 1� W E N m �(UJ7 m y INTERN r S•�:t: `.j.t.r.� .s1 '::i'y MIN.1� 0 W w a`! N 24 �- Ic1 iy'! f=:ie,<":= l.' MIN. ot 0 W v, 21 4 aI XU 21'-'1/4• 29 28 MIN. 3 20 35 34 1 yy EMB. 4 I I c m IN 34 19 21 1 2 31 32 4 OPERATING UNIT 1X BUCK 6 OPIION IN YASONRY/L17NCRLTE • RlCRT HAVE SHOWN, LffIIT HINGE OPAISITE SHOWN 1' MIN. (SCALE.` 6" 1' MIN. • 5 c a v • \�� R7APCDN MASONRY AND WOOD SCREW ANCHOR SPADING (ITEMS 15 R 134). SEE SEE DETAL A SHEET 5. 1• NIN. I y \\\ ON SHEET 7 � O MINIMUM E B DMEIyF�I��1" �/"WROH' SECPON OF HEAD OR JAMB IS LONG 1' MIN. .° v' • 1/4• I— Mm. 2 -A V ° SHIM 4 OPERATING UMT 1X BUCK > t 1/2 FUN. EMB. OPTION !N YASONRY/L17NCR6TE - (SCALfi 6" =1'-0"J CONCRETE/ OPTIONAL MASONRY/CONCRETE INSTALL YHR` BYCROSS SECTION OF HEAD OR JAMB OTHERS V.,, �/STATEOF' 10 HTITTTTTI� C,ertifiM& No.: N I o e G 2: c- 2 Wend By: ,ID Date Review /,.�,, S MFE AS NOTED m an EAG aB.S. SAFFEL AUDAPMIS 5PYRWcmFLQROA P.E NO. MIDI o"INING NO-- cERna0RlcS.ILC. In W. FAIRSAWS AVE. GM a70 JW0509-03 WRITER PARK,FL inQ9 SHEET 4 OF 7 CE I,.DE RT.OF AUIH.N0. �85T0 2 SEE DETAIL B 2 SHEET 6 0 SEE DETAIL B zf j rn SHEET 5 SEE DETAIL A 1 SEE DETAIL B :a e o moo] N V �6"� �6• SHEET 6 io 6' 12 1/2' TYP. 6"1 — SHEET 5 0 0` m m Ln • J { l ! I I Cpwm S o y c c I ct O -j C an V N 5 ao io 5 I X '�' m ca coo 4 U _ _ TYR 4 SEE DETAIL D a Z TYR co SHEET 6 e` c Y A A B 1 m eo N to vl - n a, m G C n a p n to m 3 3 �vlw \ u 4 U o n 5 T1'P. 11 n 7TYP. n a •� co ¢aoo al � of J ¢ _ L4 in WIZ � ZO I 1 1 T 1 1 1 � owcn o w o'a I I1 SEE DETAIL A SHEET 5 I I l 6" F�H-12 1 /2" TYP- 6" —{ — SEE DETAIL A w 3 N y= 37 1/2" 5I o 74" SHEET o 0 TI ALL DOOR MODELS ARE VIEWED 18 � 1 a a FROM THE INTERIOR SIDE J m O SEE DETAIL E SHEET 6 o�oo WIInTn z M, ANCHORING LOCATIONS ANCHORING LOCAT ON DOUBLE KUKtl' J p Z OUTS1iING SINGLE UNIT XJ UTSJYI UN T V x o SCALE.- 1 $" =1 -O- SCALE.* 11Z' =1'-0" w a 0 w w v) w¢w� o 2 5 T y • T f "' p r� UJ N 00� C N Q O tt ttl\111111f/rf Sp �• •EI` !�p�if OVm¢V T r4aas. G Z 2/5/08 No o :9 fjSTATE of : �� AS NOTED owe. or: EAG cKv erS. SAFFEL DPAW.NG No_ 14 �O,p •, .c 10.7-11 q, c'�.` FLouwnnv.Eg..Naocolol •�Dii1�:�G.1`� DETAIL A DETAIL B �, %trs 'frS,ONA' EC�ttt CERTWGRK5,LLG 177W\n A g9PARX.FL R799`9 JW0509-03 5 of 7 y SCALE- �� —1'-G- SCALE' X =1•-O" FRPE CERT. of AIfTIL No 385T0 IV ilmmI Cerhficatim NO.: NI oD G ZJ3 — 2y' Reviewed By: Die n9VielV7. 1— 4 9/16° --{ ANCHOR ® EXTERIOR SIDE 1 1 EXTERIOR 3/4" 1 1/4° 2 13 7 34 6 5/8 1/2- / 2- 20 0 60, CO rn`�' N 1 33 4 3334 • r INTERIOR 13 5 1�2" 17 a o dm� molnC S R y 7? LL 5 1'/2" c q DRILL 3/8" ASTRAGAL 1 >c M a m 4 RETAINER BOLT HOLE 33 s THRU FRAME/MASONRY 3334 8 x 1-3/8' DEEP Y DETAIL B DETAIL C DETAIL D DETAIL A -BINGE KWAT/NG DETAIL _TAROWBOLT STRIKE PLATE FOR BEAD STRIKE' PLATES TO JAMBS STRIKE PLATE'S TO ASTRAGAL SCALE. 3" =1'-O" SCALE.. 3" =1'-O" SCALE.- 3/8" =1'-O•' SCALE` 3/8" =1'-0" N z La m U O J M Cma Q at WU' O -1 I z woul W � z O DRILL 3/8" ASTRAGAL RETAINER BOLT HOLE 1/2' x 1/4" CU-D SPACER v) F d v o THRU THRESHOLD/MASONRY x 1-3/8" DEEP ? 30 r a 21 o -d { ^ 1/8" TEMPERED GLASS o ° z .zz 0000 1 v 1/2' AIR SPACE ® N 3 in u51 TYP. ° M1 7 34 g :o 0.090" PvB z Z �i 4i a a 1 INTERLAYER BY Q 0_j� N z SOLUTIA f EXTERIOR (NOA #08-0206.01) z c clz z Z 12 1, 5/8' GLASS 2t 1/8" ANNEALED `yr • BITE rn 4 m o inm�o to o0 w DETAIL E DETAIL F - ENDURA AS9RACAL �' DETAIL G - ODL 3 ASTRAGAL RETAINER STRIKE ('j/ATE fY1R S/LL FASTENER SPAC/NC USE 821 PP PF N a N r 1OP SCALE: 3" =1'-0" SCALE: AT, DAm 2/5/08 3 scALL*AS NOTED Dhc. sn EAG cw- arS. SAFFEL TATE OF • _ �O.C•..F -T% : •c�' FL'Ri YQ-I Y11 ALEMSPOU OFOA P.END.Id1°I < : �`S'• C O n 1 Q.• O\� CERTNOBxS.LLC. DRAW*G No: JW0509-03 `� 127 W. FAMBANKS A%E SM.M rr 1ONA4ti WINTER PARK. FL 22788 SHEET 6 OF 7 �+ V .'• rrrl#/111111111` FDPE CENT. OF MUM HM26SM .•v mW11 IV Ill "I! Certification No.: /V / a Zs3--_,� nc1r�E;.,C-r _ JT L � 4 9/16" —{ IA 1-2 3/16"� FLAVEROOLATEV PINE SCALE.- 6" =1'-O" 2 r 2 1/2" ----I O O O 0 4" O O O O 4— 1/16" (Min) 0 1ltUTT HINGE 4x�z12 GA. SCALE: 6" =1'-0" 9/16" I n \lOdfPRE SIGN 1IEATXERSTRIP �QDS-650 SCALE.- 6" =f'-O" ��r\ENDURA AWVINU: ASTRAGAL e/ ctLoO BLOCK - FOOD �`? SCALE.• 6"=1.'-0" �I SCALE:• S" =1'-O" '�`� SCALE.• 18" ASTRAGAL BOLT ° >2 dZ1IANTC 8•C/YRELSTEEL HRROOD'VAT`•t SCALE.• 6" =f'-O" � � `•�O 13/16"� 26,' 1 11/16" 3% TOP RAIL (LYL) XINCE STILE lLVLJ 32 LA7CH STILE LVL SCALE: 6.. =1 ESALE: - =f- Al SCALE.• 6" =1"—O" RLBTE4N25CA NIN GALV. �r� SCALE: 6" =1'-O" r 2 1 ---� 1 3/4' 1 I I Oo. Oo O ASTRAGAL SILL ODL ALLEN FRAME 18 scALE:• s"=1'-a•• 30 scAL�:• s•• =1'-0" 3/1,6" C—SINK. F— NOTE 1—USE #10 WOOD INSTALLATION SCREW W/ 1 1/27- EM i No 0 WHEN INSTALLING INTO WOOD SUBSTRATE AT HEAD / 2—USE #8 x 2 1/2" PFH WOOD SCREW WHEN INSi / 3—USE 3/16" 1TW TAPCON ANCHOR W/ 1 1/4" MIN. EM of WHEN INSTALLING INTO CONCRETE/MASONRY SUBSTRATE AT SA TE SILLS. ^ O . 10-7-11 D�AIL A — COU���INK D�AIL � S SCALE.- 1/I" =1'—O.• �•�S�ONAI.. Ce(tifica on NO.: A/ 2 Reviewed By: io - Date Review I 0 r 00 n o o Om Oct) N Q m N O • 0 .0 m Y N 0 _J r- 0-m1n�n k�trx So, ca1L E Y —AS NOTED B1Fc. sT: EAG cm sr-S. SAFFEL ALENS SPVROU FLORIOAPEN0.W:Q1 ORAVANG NO, TV' CERORKS. LLC Jµ10509-D3 127 W, FAUWAN93 AVE STE. 438 HOTTER PARK, FL 3V@9 OF 7 FBPE CERT.OF AU NO.2020 OFFICE USE ONLY: DATE FILED• 1 \3 REVISION FEE: SO. C00 1. PERMIT # \ al RECEIPT # PLANNING & DEVELOPMENT BUILDING & CODE REGULATIO: 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5 (772)462-1553 1 APPLICATION FOR BUILDING PERMIT PROJECT INFORMATION LOCATION/SITE Al s'I �97 r� ADDRESS: I �7 37 S� rf /EI�CE� �� 3 2. DETAILED DESCRIPTION OF PROJECT REVISIONS: IN t 't'-FAt) o StU7TF-9S \(✓OyCcJ -r.4 !?Ft T� 1MPAS% QESd71,AJ 3. CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: BUSINESS NAME: QUALIFIERS NAME: ADDRESS: CITY: PHONE (DAYTIME): ST. LUCIE COUNTY CERT. #: STATE: FAX: 4. OWNER/BUILDER A INFORMATION: NAME: / W 8w; yd)V,4 LP ADDRESS: 30 2 CITY: FT /E STATE: PHONE: 77a- �2/ FAX: 5. ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: PHONE (DAYTIME): STATE: SLCCC: 9/23/09 Revised 04/26/2010 ZIP: ZIP: ZIP: FAX: D - ui� ST. LUCIE COUNTY BUILDING DIVISION REVIEWS NCIE FOR CO REVIEWED BY DATE PLANS AND PER IT PAUST BE KEPT ON JOB OR BE MADE NO INSPECTION" LL MIdMFI1�4D MIAMI--DADE COUNTY FLORIDA PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING, ENVIRONMENT, AND `dUI:A OI Yi 11805 S.W. 20h Street, Room 208 AFFAIRS (PERA) h`' "'f' Miami, Florida 33175-2474 _ BOARD AND CODE ADMINISTRATION DIVISIONy F 786 315 2599 NOTICE OF ACCEPTANCE OA t 1 PGT Industries �, � �,��,• _ +�.� � 4 , ��� 1070 Technology Drive Nokomis FL 34275 n } SCOPE: This NOA is being issued under the applicable rules and regulations over r g the s ,; oft�..c�onstruction materials. The documentation submitted has been reviewed and accepted by Mi nty PERA- Product Control Section to be used in Miami -Dade County and other areas where allowed b}-the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series "SH 700" Aluminum Single Hung Window - L.M.I. APPROVAL DOCUMENT: Drawing No. 404020, titled "Alum. Single Hung Window, Impact", sheets 1 through 11 of 11, dated 09/01/2005, with revision "D" dated 10/07/2011, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P. E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and Expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING; Large and Small Missile Impact Resistant. LIMITATIONS: Miami -Dade County Product Control Approved Shutters Or Protection Devises shall be required for GIazing Option "M" at installations above 30 Ft, above ground (See sheet 1 of 11). LABELING: Each unit shall bear a permanent label with the manufacture's name or logo, city, state, model/ series and following statement: "Miami -Dade County Product Control Approved" unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami=Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official, This NOA revises NOA No. 11-0405.10 and consists of this page 1, evidence pages E-1, E-2 and E 3, as well as approval document mentioned above, The submitted documentation was reviewed by Jaime D. Gascon, P. E. MIAM dADE CO N7'Y l• I9 t, d3 NOA No. 11-1013.14 Expiration Date: March 26, 2016 Approval Date: November 03, 2011 Page 1 PGT Industries NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer's die drawings and sections. 2. Drawing No 4040 20, titled "Alum. Single Hung Window, Impact", sheets 1 through 11 of 11, dated 09/01/2005, with revision "D" dated 10/07/2011, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P. E. B. TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411 3.2.1, TAS 202 94 along with marked up drawings and installation diagram of an aluminum single hung window, with fin frame, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-4957, dated 10/03/06, signed and sealed by Edmundo Largaespada, P. E. (Submitted under previous NOA No.07-0322.06) 2. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per. FBC, TAS 201 94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of an aluminum single hung window, with fin frame, prepared by Fenestration Testing Laboratory, Inc., Test Reports No.'s FTL-4958 and FTL-5063, dated 10/03atid 11/21/06, both signed and sealed by Edmundo Largaespada, P. E. (Submitted under previous NOA No.07--0322.06) 3. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201--94 2) Cyclic Wind Pressure Loading per FBC, TAS 203 94 along with marked up drawings and installation diagram of an aluminum single hung window, with fin frame, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-4645, dated 08/11/05, signed and sealed by Edmundo Largaespada, P. E. (Submitted under previous NOA No.07- 0322.06) 4. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94 2) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of an aluminum single hung window, with fin frame, prepared by Fenestration Testing Laboratory, Inc., Test Reports No.'s FTL-4649 and FTL-4723, dated 10/05 and 08/11105, both signed and sealed by Edmundo Largaespada, P. E. (Submitted under previous NOA No. 05 1018.01) Jaime D. Casco- , P. E. Product Control Section Supervisor NOA No.11-1013.14 Expiration Date: March 26, 2016 Approval Date: November 03, 2011 E.-1 i Z PGT Industries NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED B. TESTS (CONTINUED) 3) Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Small Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure )goading per FBC, TAS 203-94 6) Forced Entry Test, per F13C 2411 3.2.1, TAS 202-94 along with marked up drawings and installation diagram of an aluminum single hung window, with fin frame, prepared by Fenestration Testing Laboratory, inc., Test Reports No.'s FTL-4947 and FTL-4650, dated 08/11105, both signed and sealed by Edmundo Largaespada, P. E. (Submitted under previous NOA No. 05-1018. 01) 4) Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202--94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked —up drawings and installation diagram of an aluminum single hung window, with fin flame, prepared by Fenestration Testing Laboratory, Inc,, Test Reports No.'s FTL-4948 and FTL-4646, dated 08/10105, both signed and sealed by Edmundo Largaespada, P. E. (Submitted under previous NOA No. 05 1018.01) C. CALCULATIONS ; . 1. Anchor verification calculations and structural analysis, complying with FBC 2007,. dated 01/11/2011, prepared, signed and'sealed by Robert L. Clark, P. E. Complies with ASTM B1300-04 (Submitted under previous NOA No.11-0128.03) D. QUALITY ASSURANCE I. Miami —Dade Department of Permitting, Environment, and Regulatory Affairs (PERA). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 11-0624.01 issued to E.I. DuPont DeNemours & Co., Inc. for their "DuPont Butacite® PVB Interlayer" dated 09108111, expiring on 12/11/16. 2. Notice of Acceptance No. 114325.05 issued to Solutia Inc. for their "Saflex and Vanceva clear and color interlayers" dated 05/05/2011, expiring on 05/21/2016. Jaime D. Gasco ►, P. E. Product Control Section Supervisor NOA No. 11-1013.14 Expiration Date: March 26, 2016 Approval Date: November 03, 2011 E-2 PGT Industries NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED F. STATEMENTS 1. Statement letter of conformance and compliances with the FBC -2007 , and FBC 2010, dated October 07, 2011, signed and sealed by Anthony Lynn Miller, P. E. 2. Statement letter of no financial interest and independency, dated October 07, 2011, signed and sealed by Anthony Lynn Miller, P. E. 3. Laboratory compliance letter for Test Reports No.'s FTL -4957, FTL-4958, FTL-5063, FTL-4645, FTL-4649, FIFL--4723, FTL-4947, FTL-4650, FTL--4948 and FTL-4646, issued by Fenestration Testing Laboratory, dated 10/03/06 through 08/10/05, all signed and sealed by Edmundo Largaespada, P, E. (Submitted underprevious NOA No. 07-0322.06 and 05-1018.01) G. OTHERS 1. Notice of Acceptance No. 11-0405.10, issued to PGT Industries for their Series "SH-700 Aluminum Single Hung Window - L.M.I.", approved on 04/2112011 and expiring on 03/23/2016. 9 Q- �- ,Jaime D. Gasc n, P. E. Product Control Section Supervisor -NOA No. 11-1013.14 Expiration Date: March 26, 2016 Approval Date: November 03, 2011 E-3 ® GENERAL NOTES: IMPACT SINGLE HUNG FLANGED AND INTEGRAL FIN WINDOWS 1. GLAZING OPTIONS: (SEE DETAILS ON SHEET 2) A 5/16" LAMI CONSISTING OF (2) LITES OF IV ANNEALED GLASS WITH A .090 DUPONT BUTACITE OR SAFLEXIKEEPSAFE MAXIMUM PVB INTERLAYER. B. 6116" LAMI CONSISTING OF (1) LITE OF 11W ANNEALED GLASS AND (1) LITE OF 1/8" HEAT STRENGTHENED GLASS WITH A .000 DUPONT BUTACITE OR SAFLEXIKEEPSAFE MAXIMUM PV13 INTERLAYER. C. 5/16" LAMI CONSISTING OF (2) LITES OF 118" HEAT STRENGTHENED GLASS WITH AN .090 DUPONT BUTACITE OR SAFLEX/KEEPSAFE MAXIMUM PVB INTERLAYER. D. 7/16" LAMI CONSISTING OF (2) LITES OF 3116" ANNEALED GLASS WITH AN .090 DUPONT BUTACITE OR SAFLEXIKEEPSAFE MAXIMUM PVB INTERLAYER. E. 716" LAMI CONSISTING OF (1) LITE OF 3/16" ANNEALED GLASS AND (1) LITE OF 3118" HEAT STRENGTHENED GLASS WITH AN .090 DUPONT BUTACITE OR SAFLEXfKEEPSAFE MAXIMUM PVB. F. 7/16" LAMI CONSISTING OF (2) UTES OF 3/16' HEAT STRENGTHENED GLASS WITH AN .090 DUPONT BUTACITE OR SAFLEX/KEEPSAFE MAXIMUM PVB INTERLAYER. G.13/16" LAMI IG: (1) UTE OF IV TEMPERED GLASS, AN AIR SPACE AND 6/16" LAMI CONSISTING OF (2) LITES OF 1/8" ANNEALED GLASS WITH A .090 DUPONT BUTACITE OR SAFLEXIKEEPSAFE MAXIMUM PVB INTERLAYER. 0 H.13/1S" LAMI IG: (1) LITE OF 1/8' TEMPERED GLASS, AN AIR SPACE AND 616" LAMI CONSISTING OF (1) LITE OF 1/8" ANNEALED GLASS AND (1) LITE OF 118' HEAT STRENGTHENED GLASS WITH A90 DUPONT SUTACITE OR SAFLEX/KEEPSAFE MAXIMUM PVB KrERLAYER. I. 13/16' LAMI IG: (1) LITE OF 10 TEMPERED GLASS, AN AIR SPACE AND 6/16" LAMI CONSISTING OF (2) LITES OF 1I8" HEAT STRENGTHENED GLASS WITH AN .090 DUPONT BUTACITE OR SAFLEWKEEPSAFE MAXIMUM PVS INTERLAYER. J.13/16" LAMI IG: (1) LITE OF 1/8" TEMPERED GLASS, AN AIR SPACE AND 7/18" LAMI CONSISTING OF (2) LITES OF 3H8"ANNEALED GLASS WITH A .090 DUPONT BUTACITE OR SAFLEXMEEPSAFE MAXIMUM PVB INTERLAYER. K 13I1S' LAMI IG: (1) LITE OF IV TEMPERED GLASS, AN AIR SPACE AND 716" LAMI CONSISTING OF (1) LITE OF 3/10" ANNEALED GLASS AND (1) LITE OF 3/16' HEAT STRENGTHENED GLASS WITH AN .090 DUPONT BUTACITE OR SAFLEX/KEEPSAFE MAXIMUM PVEL L. 13116' LAMI IG: (1) LITE OF IV TEMPERED GLASS, AN AIR SPACE AND 7/16" LAMI CONSISTING OF (2) LITES OF 3/16" HEAT STRENGTHENED GLASS WITH AN AD DUPONT BUTACITE OR SAFLEX/KEEPSAFE MAXIMUM PVB INI'F.RLAYER. &M. 13/16" LAMI IG: (1) LITE OF 1/8" ANNEALED GLASS, AN AIR SPACE AND 6/16' LAMI CONSISTING OF (2) LITES OF IV ANNEALED GLASS WITH AN .090 DUPONT BUTACITE OR SAFLEYJKEEPSAFE MAXIMUM PVB INTERLAYER. 2. CONFIGURATIONS: 'OX° (1H, VIEW AND RADIUS TOP, ALL W/ LOW OR HIGH SILL OPTION) ®3. DESIGN PRESSURES: (SEE TABLES, SHEETS 3) A. NEGATIVE DESIGN LOADS BASED ON TESTED PRESSURE AND GLASS TABLES ASTM E 1300A2. S. POSITIVE DESIGN LOADS BASED ON WATER TEST PRESSURE AND GLASS TABLES ASTM E 1300-02. 4. ANCHORAGE: THE 33113%STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT. SEE SHEETS S THROUGH 11 FOR ANCHORAGE DETAILS. S. SHUTTERS ARE NOT REQUIRED. 0. FRAME AND PANEL CORNERS SEALED WITH NARROW JOINT SEALANT OR GASKET. ®7. REFERENCES: TEST REPORTS FTL-4645, FTL4646, FTL-4647. FTL-4648, FTL-4649, FTL4650, FTL-4651, PTL4723, FTLA957, FTL-4958 AND FTL•6083. ANSI/AFB,PA NDS•2001 FOR WOOD CONSTRUCTION ADM•2000 ALUMINUM DESIGN MANUAL 0. SERIES/MODEL DESIGNATION SH700, ALSO REFERRED TO AS SH701. 9. THIS PRODUCT HAS BEEN DESIGNED & TESTED TO COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE, INCLUDING THE HIGH VELOCITY ® HURRICANE ZONE (HVHZ). NOa.sq FL6g VWbly Bette a.`.aw,e sue ar.s Oe1e�' sumo N75 ! + 11 4040.20 NOA DRAWING MAP SHEET GENERAL NOTES ............. I GLAZING DETAILS ............ 2 DESIGN PRESSURES....._ 3 ELEVATIONS ... ........... _... 4 VERT. SECTIONS............ 5 HORIZ. SECTIONS.......... 6 PARTS LIST..................... 0 EXTRUSIONS .......... _...... 7 CORNER DETAIL .......... _.. 7 ANCHORAGE ............... _.. 8.11 FRODUCrIMMED w eomptying wih the Fkdda Building Code _ , . _ . JINN WileP,,� c al"� of(( t A. L�nldIXMAIlLEi3, P.E. FL P.E.A 58705 ® NOTE: 1 LAMI IG OUTBOARD LITES MAY BE UPGRADED TO 3/16" WITH NO CHANGE IN DESIGN PRESSURE. 1/2" NOM. 1[j1h" MOM. GLASS BITE GLASSBITE EXTERIOR INTERIOR �V7" (ALL SECTIONS) ® 37 or 82 63,Sa or 85 70 70 1/0"ANNEALED OR HEAT STRENGTHENED GLASS 3NB"ANNEALED OR HEAT STRENGTHENED CLASS 090 SOLUTIA OR DUPONT PVB INTERLAYER 000 SOLUTIA OR DUPONT PVB INTERLAYER IVANNEALED OR HEAT STRENGTHENED GLASS 3116" ANNEALED OR HEAT STRENGTHENED GLASS 5/16" NOM. 711W LAMINATED 5/16" LAMINATED GLASS 7/16" LAMINATED GLASS 112" NOM. GLASS SITE I ,88 or 92 89,90 or 9' 7D 70 VS' ANNEALED OR HEAT STRENGTHENED GLASS .090 SOLUTIA OR DUPONT PVB INTERLAYER 1/8" ANNEALED OR HEAT STRENGTHENED GLASS 5/16" LAMINATED AIRSPACE 1/3" ANNEALED OR TEMPERED GLASS & 13116' NOM. 13116" LAMI IG GLASS W/ 5/16" LAMI faw/if D M7 CHANGES 7MSSHEET RIK- 040111 1 C CMWGEDCAP GLASS TYPE70 TEMPERED FROMHG NO K%K-88V 11/I&4B B ADD REMB2 T06/16LW I.G. 0 AW MA 6 LAW IGNOTE PA. QX 1�8 NZBMFL992/I �MM5 dd 224mr V2" NOM. GLASS BITE 1 3/16" ANNEALED OR HEAT STRENGTHENED GLASS 090 SOLUTIA OR DUPONT PVB INTERLAYER 3116" ANNEALED OR HEAT STRENGTHENED GLASS 7/16" LAMINATED AIR SPACE IV TEMPERED GLASS& 13/16' NOM. IWi6" LAMI IG GLASS W/ 7116" LAMI ING WINDOW IMPAG 2 d 11 "4040-20 WLuz SSATE of 02, �O� •.,. FL.!�R. �IS 0,10 �'��FSSIONP� A. L1/I�N' MILD P.E. FL P.E.# 68705 111 FLANGE OR INTEGRAL FIN WINDOWS Wl HIGH SILL OPTION BASED ON FLANGED WINDOW TIP -TO -TIP FRAME DIMENSIONS WINDOW HEIGHT WIDTH GLASS TYPE or 80" 1 W. 70" 72" 74" TABLE 1. TB" 48" A.S,M +80.0 -80.0 +80,0 -80.0 +80.0 -80.0 +80.0 -60.0 +60.0 •80.0 +80.0 -80.0 +60.o -80.0 60" A,B,M +80.0 -80.0 +80.0 -S0.0 +80.0 .80.0 +8Mo -80.0 +00.0 •80.0 +60.0 -80.0 +79.0 -79.0 32" A,S,M +80.0 00.0 +80.0 -80.0 +BD.O 80.0 +80.0 80.0 +70.8 -78.8 +77.3 -77.3 +769 •75.0 631/8" A,B,M +60.0 •80.0 +B0.0 •B0.0 +78.8 .70.8 +78.2 -78.2 +76.9 -76.0 +75A •76.4 +74.D .74.0 t)PTOS11/8" C,D,E,F,G,H,I,J,KL +Bo.o -80.0 +60.0 -60.0 +60.0 -60.0 +K0 •80.0 +b0.0 -e0A +80.0 -00.0 +60.0 -80.0 STANDARD VIEW & RADIUS TOP FLANGE OR INTEGRAL FIN WINDOWS W/ HIGH SILL OPTION ® BASED ON FLANGED WINDOW TIP -TO -TIP FRAME DIMENSIONS WINDOW HEIGHT WIDTH GLASS TYPE I 303ro" 4V' 1 60618" 63" 72' 74" TABLE 2. 78" 48" A,B,M +00.0 -80.0 1 +80.0 1 -80.0 1 +80.0 1 -8D.0 +60.0 •60.0 +7o•0 -70.0 1 +70.0 1 -70.0 +70.0 70.0. 60" A B,M +80.0 .80.0 +00.0 -BD.0 +80.0 •80.0 +79.9 •79.9 +70.0 -70.0 +70.0 1 •70.0 +70.0 .70.0 62" A B,M +80.0 -80.0 +00.0 -00.0 +00.0 •80.0 +76.9 .76.9 +70.0 .70.0 +8&8 40.6 +07.8 -87.0 631/8" A,B,M +80.0 -80.0 +80.0 -60.0 +80.0 •00.0 +75.0 -75.0 I;wo 8&0 +68.1 4)B.7 +65.5 •65.5 UPT003118" O,H,I,J,KL +80,0 80.0 +80.0 80.0 +80.0 -D.O +80.0 -80.0 +70.0 -70.0 +70.0 -70.0 +70.0 •70.0 "0" MEETING RAIL HT. "X" STH 10, HT. MEETING RAIL t "XI1" "O" MINUS WI SASH T. HT. MEETING RAIL 41, 0. 1311V LAMI 10 -118" T, AIH SPACE, 5115" LAMI - 10A,.000,118"A) FTL4848, 4723 H.13110" LAMI IG -118" T, AIRSPACE, 5118•' LAMI - 01B"A,.090,1/8"HS FTL-4848 L 13/16" LAMI IG -118" T. AIR SPACE, 6118" LAMI - (118"HS,.080,118"H3) M-4640 J. ISMS LAMI IG -1/8" T. AIR SPACE, 7118" LAMI - (3119-A,.090, 3/18"A) FTL-4649, 4050 K. 13/18" LAMI IS -1/8" T. AIR SPACE, 7118" LAMI - (3/1OW-060. 3/1S"HS) FTL•4849, 4650, 4050 L 13118" LAMI 10.118" T, AIR SPACE, 7/16" LAMI - (3/18"HS .090, 3/18"HS) FTLr4649, 4650 9 IM 13118" LAMI 10.1183A AIR SPACE 5116" LAMI- (VB••A .080, tl8"A)AN I• IL-Q w I NOTES: 1. WINDOWS WITH THE LOW SILL OPTION ARE LIMITED TO A POSITIVE DESIGN PRESSURE OF +64.0 PSF OR LOWER AS SHOWN IN THE TABLES. NEGATIVE DESIGN PRESSURES ARE UNEFFECTED. 2. FOR INTEGRAL FIN WINDOW DESIGN PRESSURES USE THE ABOVE TABLES BY DEDUCTING 1" FROM THE FLANGED TIP -TO -TIP FRAME DIMENSIONS. (� 3. AVAILABLE SASH HEIGHTS FOR CUSTOM WINDOWS ARE 12 618" MINIMUM TO 38" MAXIMUM. & N-112H. 1 -2ah Bro---- - .t p MS 9 r 11 404020 I111111 �•j�.•J�,E.NSF••••., P'iC�i is ; Ho, 58105 six �o.FLOR\DP •���: A. LYISI(IIIUIL, P.E. FL P.E.9 60705 531/8" MAX. FLANGED WIDTH 52118" MAX. I.F. WIDTH 49 6/S" MAX. FIXED (ALL) D T-FDLO 75 SEE DLO TABLE O % I.F.MAX, 1 I Dom+ H"rQ SDI I7 TABL L , AX. TTAE I x / I�I 38SASH1/16 ()(MAX.HEIGK ) VENT DLO (ALL) DETAIL A 1/1 A A I.F. O HEI T 76' MAX. FLANGED TE HEI HT X NO 4 DETAIL B VIEW (STANDARD SASH) 7T B E� I 76" MAX. I 76" MAX. I I.F. I.F. SEE DLO I HE[ HT E HEI HT TABLE ® SEE OLD A TABLE O O / 78" MAX. 78" MAX. FLANGED � FLANGED T HEI HTSEE DLOTABLE X SASSEE DLO TABLE X j g SASH !J HEIGHT HEIGHT -7 .--j --F DETAIL D DETAIL E VIEW (CUSTOM SASH) RADIUS TOP (CUSTOM SASH) NOTES: 1. SEE SHEET 6 FOR VERTICAL AND HORIZONTAL SECTION DETAILS. 2. SEE SHEET 7 FOR CORNER DETAIL VIEWS. 3. SEESHEETS 8THROUGH 11 FORANCHORAGE INFORMATION. 4. SASH HEIGHTS FOR STANDARD SASH WINDOWS (DETAILS B & CARE BASED ON A THREE OVER TWO FORMAT. PA.BOXIM n�I" N=MBI, FL3W4 . nsibl9 Better eHM X Of DETAIL C VERTICAL DAYLIGHT OPENING DETAIL FIXED LITE LOW SILL HIGH SILL A 341/2" 34 3118" B 415/8" 411/4" C 411/4" 407/8" D 52 5/8' 5211/16" E 521/4' 52 5/1B' SH DETAIL LOW SILL HIGH SILL A 34112' 34 3116 B 27 7/16" 27118" C 27 7/16" 271/8" D 16 31W 15314. E 16 3/8' 15 3/4" TABLE 5. l/VL7 VVIIVUVPY IMI-AL 4 d 11 �404"0 75" MAX I.F. HEIGHT MAX. FLANGED HEI HT S N E4 "tlllll I/,,, V4NN Al/4, 55705 of= �'PO'•.. 9SA GF : � �� T� .' • flOA�aPtC1���� SION0, ' A. LYI•G U111161, P.E. FL P.E.# 68705 A If-2.784•---�{ III INSIDE Q/ (LOW SILL) SEE NOTE ABOVE ULTRALIFT 12 ONLY NOTE: MIN. (1) SWEEP LATCH AT VENT CENTERLINE OR 26 27 OPTIONAL BOTTOM LOCKS, (1)6' FROM EACH SIDE OF SASH. INSIDE MAX VENT DAYLIGHT OPENING NOTE: BALANCE PARTS USED ® BASED ON SASH WEIGHT 9,10,11,15,16 �.•—MAX. FIXED LITE DAYLIGHT OPENING OUTSIDE r+ MAX. WIDTH SECTION A -A INTEGRAL FIN (I.F.) FRAME SECTIONS® INSIDE 47 2. 48 HIGH SI 2 LOW 31).L HIGH SILL 48 LOW SILL HEAD 88 2.1710"j ®I.F. FRAME _T_Ao5E 53 II OUTSIDE o ULTRALIFT 12 ONLY ALTERNATE HIGH SILL UTECHNOLOOYORIVE taoKoneaFLa�c— T _E rroi I+ ALUM. S NaI�PLl9,0.M2T4 TFL' l�kfb�•Better eK.am BFBDO SECTION C-C RADIUS TOP DETAIL - FLANGED V ING VVINDOW IMPAC e e.� - 5 r 91 404020 the modde �c No.55705 • �i,k� ;may S1AS60 r SIONA w A. LYN VIR10HIt WE. FL P.E.# 68705 ITEM DWG# . DESCRIPTION PGf# 1 4002A FLANGE FRAME HEAD 612225 2 1165 08 X 1.000 QUAD PN. SINS 781 POA 3 4003C FLANGE FRAME SLL(LOWSILLY 612228 5 1628 . ADHESNE EN CELL FOAM PAD 7PAD1626 8 4064 FLANGE FRAMS 612227 7 4025 SASH STOP 812244 6 4025 SASH STOP (EGRESS)1.128 LONG 612244 B 4029 SPIRAL BALANCE, 3I8",'a' OR I Via" 10 1080 BALANCECOVER, 8f8"OR5w 6BALCVRB70 11 #8X.750PH.PN.6MI8 7034PA 12 BALANCEBOTTOMBRACKET 7BALTBKT 13 10851`1086 SASH TOP GUIDE ' 42604 15 #8 Xt PHILLIPS FLATHEAD S. STL 78XIFPAX 16 108D-1 BALANCE COVER,11n8" 6BPLCVRO70 17 4003 SASH STOP COVER 04053 18 4029-1 SASH BRACKET 7ULB KT 19 08.32 X 1Q" I.G. PH. FH. TYPE F S. STL 7832Xl2FPFX 21 4064C OtkD NE GRAIL 04054C 23 4008C SAS TO RAIL 64008 25 1236 WSTP 170 X170 BACK FIN SEAL 676160 26 1023 SWEEP LATCH 71006 27 1018 #5 X 0 5 PH. FL.3MS 7068 28 1 4007 SArH 60 RA1L (LOW SILL) 65230 30 1 1228 WSTP., BUILS VINYL OTP249 31 4008 SASH $1150 RAIL 612231 34 1268 SASH PACE GUIDE 42501 36 1622 LAMSETTINOBLOCK3/32"X26184"X1° 7122K .36 1052 lAM 10 8&T11N0 BLOCK 1"X 314" X 1118" 71062K 37 1224 VINYL GLAZ. BULB IC OTP247W,K 38 1226 NNYLG B BULB(THIN) 6TP24.0K 41 40300 GLAZING SM. SMS LAM. GLASS. 640390 42 4044B GLAZING BEAD, 5n6 LAWVVIORLL KIT 844703 44 4222A GLAZM B 7n8" 64 222 45 985C GLAZING BEAD, 7116" LAM W/GRILL KIT 6985 46 4067 OWING DEAD, 13n8" LAN I.O. 64067 47 4071A FRAME. I.F. H 04071 46 4072A FRAME,L .LOWSILL 64072 49 4073A FRAfiE, LF. HIGH SILL 64073 60 4074B FRANE,IF. JAM6 64074 62 4009 SILL LATCH (EGREW (LOWSLL) 764009 53 1086 SPRING, SILL LATCH (EGRESS 76PRNO 4 2740 SILLLATC SS EIG LL) 62740 55 1014 SCREEN FRAME (NOR. 8 VER.) 61014 68 1630 SCREEN CORNER KEYW/RINGS 71630 67 1831 SCREEN CORNER KEY W/OUT RINGS 71631 68 1073 SCREENSPRINO 7CASP 59 1624 SCREEN SPLINE-,135 DIA FOAM 81624K ra eqx id7D N.aa,zu A rrEM DWGB DESCRIPTION PGT# 60 1635 SCREF-NSPLINE-.135DIAHARD 81636K 61 SCREEN CLOTH 81610 83 605 GLCHANNELAZIO(.688X.600) 2 65B3V314501 64 1161 #6X1.00PH.SUOLEIX 708X7 87 GLA4N 1n6 0 BB 4051A SASH BOTTOM RAIL (HIGH SILL 04061 8B 4050A FLANGE FRAME SILL HIGH 81LL) 64060 70 3LICONE pOW898.9650REQUN. 60 GLASS, 5(lW' , (1 A,.OB0 PVII,IIW' 81 B.0 S, Bl18"LAM1, 1/8 q.090 PVB,118°HS) 62 C, GLASS, 6116" LAM, (118°HS,.090 PV9,118°HS 83 D. GLASS, 7118" LAM, 1/8"A•090 PVB,118" 84 E. G.ASS, 7/18' (1)VA•090 PV3,118°HB) 85 LASS,7118"LM�O,(116°H8,.090PUS,1/8'HS) 86 G. GLASS, 13116" IG;118'T, AIR SPACE, 6n8° LAM, 116"A.OBD PVB,1/0 A) 87 H. GLASS, 13/16" LAM 10;118"P, M SPACE, 511 "LAM, (1/B A.090 A/8'HS 88 I. GLASS,13/1 V LAM 10;1/8"P, AIR SPACE, 5/1 B" LAM, (1/8"HS,.000 PVB,1/8'HS) 89 J. GLASS,13/16" 10;118-T, AIR SPACE, TMV LAN, OR 6°A•090 PVB 16"A) 00 K. S,13/18" IG;118T,AIRSPAC 7n8"LAW, (3/16AA00PVB,3/18"HS) 81 L OLAS3,13n8°LAM 101/87, AIR SPA(3n8"HS,.090 PVB,3n8'HS 92 O 1 1 ,1 A /1 , (!B° .0 ,1 ° �-----2.781 1 47 FRAME, I.F. HEAD ® #4071A, 6063-T6 ®48 FRAME, I.F. LOW SILL #4072A.6063-T6 .082 NOM THICKNESS 71 Au NOM THICKNESS ® ,@FRAME. I.F. JAMB ® 49 FRAME I.F. HIGH SILL #40748, 6083-T6 #4073A, 606346 (USED AS RADIUS TOP HEAD) Vidb{ &mr I sr = I NUS 18 o 11 I •�4040" m Plmida . ►n O��•'' NSE '...... iC ti'Z'r'• JG6 �� No•581p5 to Pb F �!'O '•. 51P POP' A LYI(!(4 MR1L6k�, P.E. FL P.E.# E6705 +-2.784--{ r 1.363 „jl� .082 O FLANGE FRAME HEAD #4002A,6003•TG 1.749 121.710 .062 O FLANGE FRAME JAMB #4004, 0063-TS (USED AS RADIUS TOP HEAD) (+--�III 1 or47 I.F. FRAME2 .062 830 2.0 2.784__ O FLANGE FRAME SILL (LOW) 94003C, 606346 082 .490 h-1.451-JI OSASH STOP 04025,606346 1.342 InFloy� .062 .155 .aez 21 FIXED MEETING RAIL #4054A,6063HD-T6 23 SASH TOP RAIL #4008C.6063HS-T6 .oez 2.946 3.448 I`-2.784--I 69 FLANGE FRAME SILL (HIGH) #4050A, 6063-T6 6 or 50 6or60 ' SEALANT OR GASKET — f-�•1.613-��.736 AT HEAD AND SILL VIEW D-D 17 SASH STOP COVER fW053, 8083 T550 (111 &VIEW HEAD 8 SILL, RADIUS TOP SILL) _ _ FRAME CORNER CONSTF I 2.328--+i -� 1.186FL � � oe2 1 �s .876 1.098-{•+----�_T GLAZING 41 ZING BEAD, #40395, 6083•T6 1.979 E O SASH SIDE RAIL 31 #4008, 6063•T6 28 SASH BOTTOM RAIL(LOW) 94007, 6063-T5050 f J378 1.096-I••—^I T O GLAZING BEAD 7/16" #4222, 6083-T6 68 SASH BOTTOM RAIL (HIGH) 94051A.6003-T6 ra IKp(+RB NOKOM6S, FL34ZM .050- 1;L 45 GLAZING BEAD, 7/16" #986C, 6033•T6 (USED W/ GRILL KIT) SEALANT ALONG ENTIRE JOINT I.F. FRAMEQ VIEW E-E (RADIUS TOP HEAD ONLY) oso�.678 I 1.098T 42 GLAZING BEAD, 5/16" #40448, 6063•T6 (USED W/ GRILL KIT) L�.683 I 050 -�---may1.09T 46 GLAZING BEAD, 13/li #4067, 6063-TS �EXTRUSIONS & FRAME CORNER DED �— ALUM. SINGLE HUNG WINDOW IMPAC Better a"""e mr —m.."m, sHft10 Harl 7 + 11 4040-20 WELD ALONG SCREW BOSS (2) tlwFI.id° tt1111 tr IG — a�•: •vc�se 140 *03Y W 7 w= 5fA1E 05 O.o' ............ "',,SSIONA ! SON A. LYNIIMILLLA; P.E. FL P.E.# 68705 ANCHOR QUANTITIES FOR 111 FLANGED WINDOWS TABLE S. WINDOW HEIGHT SUBSTRATE: 28.603 1 34.603 1 0.603 46.603 52.603 58803 64.603 76.000 ANCHOR TYPE: p "ONZ N U O�ON U Ze'ONZ p U O�UN U pZe p ONz 0 O�ON 0 ze'ONoz p 0 U 0 pMoNz 8N� p 0 00 0 ze'ONz 0 p 0 0'U� 0 pz"'ONpz p 0 U�UC' 0 pz"'ONpoZ p 0 Ur0 0 z WINDOW WIDTH GLASS TYPE 18.125 C,D,E,F,G, H,IJ,K,L 1 1 21 1 1 1 1 1 1 1 2 1 1 1 1 1 2 _1 2 2 1 1 2 1 2 2 1 2 2 _7 2 2 1 2 2 1 2 2 1_ 2 2 1 2 2 1 2 2 1 2 2 _7 2 2 1 2 2 _1 2 2 1 2 2 1 2 3 1 2 2 1 3 3 A,BM 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1_ 1 1_ 1 1 1 12 1111121112221222222222222222222222222222232233 _1 C,D,E,F,G, 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 24.000 H,I,J,K,L121112121212221222222.222222222232222232223332233 AB,M 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 129112121212221222222222222222232222232223332233 _1 _1 _1 _1 C,D,E.F,G, 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 2 1 1 2 1 1 32000 H,I,J,K,L 721 222231222231223232223232223332233343233343344 _1 A,B,M 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 121222 3:1222231223232223232123332233343233343341 C,D,E,F,G, 1 1 1 1 1 1 2 1 1 2 1 2 2 1 2 2 1' 2 2 1 2 2 1 2 37.000 H,I,J,K,L 221 222 337 22323222323222323232334233334 3334353 344 1 1 1 1 1 1 2 1 1 2 1 2 1 2 2 1 2 2 1 2 2 1 2 ABM 2 2 1 2 2 2 2 3 1 2 2 3 2 3 2 2 2 3 2 3 2121 2 3 _2 2 3 2 3 2 3 3 4 2 3 3 3 3 4 3 3 3 4 3 5 3 3 4 4 PSF 79 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 _2 2 2 2 2 2 2 2 2 40.000 2:1 222232223232223232323242333342334353334453344 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 _2 2 2 2 2 2 VHK 221222232223232223232323242333342334353334463344 79 44.000 ,,,, 2 2222222 2 2 2 322232 2 2 2 322332423333423333423343 2 2 2 2 2 2 2 2 2 2 _2 2 53334453445 2 2 2 2 2 A 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 B,M 222222232223232233242333342333342334353334453445 `2 PSF 79 79 C,D,E,F,G, 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 2 2 3 2 2 48.000 H,I,J,K,L 2222222322233423333423343423343 53334353345463455 ARM 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 2 2 3 2 2 222222232223342333342334342334353334353345463455 PSF 72 79 79 C,D,E,F,G 2 2 2 2 2 2 2 2 2 2 2 2 3 2 2 3 2 2 3 2 3 3 2 3 53.125 H,I,J,K,L 2222222 32223342334 34 233434333435334446344546 3456 2 2 2 2 2 2 2 2 2 2 2 3 2 2 3 2 2 3 2 2 3 2 3 ICBM 2 2 _2 2 2 2 2 2 3 2 2 2 3 3 d 2 3 3 g 3 4 2 3 3 4 3 4 3 3 3 4 3 5 3 3 4 4 4 5 3 3 4 5 4 6 3 4 4 b P.O. 1911Q0 Blau e[ NgtOMl9, FLgYltd Vtstbb Batts stnoo 1/1 8 d 11 1. ANCHOR TYPES: 1-1/4" ELCO TAPCONS 2. 1/4" ELCO 864 CRETE•FLEX ® 3-412 SCREWS 2. ANCHOR LOCATIONS ARE BASED ON THE FOLLOWING DIMENSIONS. HEAD-181/2" MAX. FROM TOP CORNERS JAMBS -17 1/2" MAX FROM TOP CORNERS 16" MAX. FROM BOTTOM CORNERS 8" MAX BELOW MTG. RAIL ® SILL - ANCHORS NOT REQUIRED 3. INSTALL PER THE ADJACENT TABLE ANCHOR GUANTTIES USING THE DIMENSIONAL CRITERIA OF VOTE 2. 4. TABLE WIDTH AND. HEIGHT DIMENSION ARE FOR FLANGED WINDOWS. INTEGRAL FIN DIMENSIONS ARE 1" LESS. 5. DESIGN PRESSURE LIMITATIONS: SIZE BLOCKS OF THE ADJACENT TABLE WITH A BOLD ITAUCIZED VALUE ABOVE THEM, INDICATE A MAXIMUM DESIGN PRESSURE WITH THE QUANTITY OF ANCHORS SHOWN IN BOLD. OTHERWISE, THE MAXIMUM DESIGN PRESSURE FOR THE RESPECTIVE SIZE AND GLASS TYPE IS AVAILABLE. TABLE KEY: MAC. PSF (DP LIMITED) 118 HEAD 2 JAMB ABOVE 2 3 MTG. RAIL RODUCTEEVISEI complying with the uEdingcngu coeptaucsNo J W.. JAMB BELOW Ieml de ProdM MTG. RAIL (FULL DP) I II II Ili - M1(4F'rrr HEAD 2 JAMB ABOVE 2 3J�isr \�`�`V�VNN ''•q * �� MTG. RAIL — JAMB BELOW No•56105 MTG. RAIL = ': LIJJ o ',opp' S �oR°P��?� SS(ONP�I``�` A. LY�t4'AMH I ; P.E. VINDOWS IW, IMPACT .cone rt.s 404020 D FL P.E.058706 ANCHOR QUANTITIES FOR STANDARD VIEW AND RADIUS TOP FLANGED WINDOWS TABLES. WINDOW HEIGHT SUBSTRATE: 29.655 37.155 44.655 62,165 59.655 67.165 74.655 76.000 ANCHOR TYPE. o coo N O Z—Zco0 NO U ON o p$ U z NOON U zrk o O Z�Zcl NO U ON o O Q$ U z NO'-ONNO U zcm o U zrzgo U ON o U z NOON U zin0 o O z—Zmo NO U Coro 0 U Z—z 0!O U WINDOW GLASS WIDTH TYPE U U U U U U U U U U U U U U U U C,D,E,F,G, 1 1 1 1 1 1 1 1 1 1 1 11 1 1 1 1 1 1 1 1 1 1 1 1 1 H,I,J,K,L 1 1 -ITT 1 1 2 2 2 1 2 2 2 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 2 2 2 3 2 3 2 2 2 3 2 19.125 A,B,M 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 1 2 2 2 2 2 1 2 2 _1 2 2 2 2 2 2 2 2 2 2 _1 2 2 2 2 2 2 2 2 3 2 2 2 3 2 3 2 2 2 3 2 PSF 79 C,D,E,F,G, 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 24.000 H,I,J,K,L 11 1 1 11 221 1 2222222222222222 2232322322232322232 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 L22ili A,B,M 1 1 1 1 1 1 2 2 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 2 3 2 2 3 2 2 2 3 2 3 2 2 2 3 2 PSF 69 77 C,D,E,F,G, 1 1 1 1 1 1 1 1 1 1 2 1 1 2 1 1 1 1 1 1 1 1 1 1 1 32.000 H,I,JKL 11 ]1-1 11 22222223222233223333 3233332233433243433243 1 1 1 1 1 1 1 1 1 2 1 1 2 1 1 1 1 1 1 1 1 1 1 1 A,B,M 1 1 1 1 111 2 2 2 2 2 2 2 3 2 2 2 2 3 3 2 2 3 3 3 3 3 2 3 3 3 3 2 2 3 3 4 3 3 2 4 3 4 3 3 2 4 3 59 B7 79 1 1 1 2 1 1 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 37.000 1 1 1 1 1 1 2 2 2 2 2 2 2 3 2 2 2 3 3 3 2 2 3 3 3 3 3 3 4 3 3 3 3 2 3 3 43324 34 4 3 2 4 3 rH.I.JKL 1 1 1 2 1 1 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 1 1 1 1 1 1 2 2 2 2 2 2 2 3 2 2 2 3 3 3 2 2 3 3 3 3 3 3 4 3 3 3 3 2 3 3 4 3 3 2 4 3 4 4 3 2 4 3 5f 79 82 79 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 40.000 H,I,J,K,L 111111 22222223223333 2233433343333343443343443363 2 2 2 2 2 2 2 2 2 2 2 2 2 2 1 2 2 2 2 2 2 2 2 2 A,B,M 1 1 1 1 1 1 2 2 2 2 2 2 2 3 2 2 3 3 3 3 2 2 3 3 4 3 3 3 4 3 _2 3 3 3 3 4 3 4 4 3 3 4 3 4 4 3 3 5 3 PSF 49 79 56 79 79 C,D,E,F,G, 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 44.0DO H,I,J,K,L 111 111 222 22233 2233342333443343443343443 34344 3354 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 ABM 1 1 1 1 1 1 2 2 2 2 2 2 3 3 2 2 3 3 3 4 2 3 _2 3 3 4 4 3 3 4 3 4 4 3 3 4 3 4 4 3 3 4 3 4 4 3 3 5 4 PSF 45 74 51 74 79 79 C,D,E,F,G, 2 2 2 2 2 2 2 2 2 2 2 2 3 2 2 2 2 2 3 2 2 3 2 17 2 48.000 H,I,J,K,L 111 111 222222332233343333443344443344444 36444 43 54 2 2 2 2 2 2 2 2 2 2 2 2 3 2 2 2 2 2 3 2 2 3 2 2 ABM 1 FI 1 1 1 7 2 2 2 2 2 2 3 3 2 2 3 3 314 3 F3 3 3 4 4 3 3 4 4 4 4 3 3 4 4 4 4 4 3 5 4 4 4 4 3 6 4 PSF 41 67 46 67 76 79 C,D,E,F,G, 2 2 2 2 2 2 3 2 3 2 3 3 2 3 3 2 3 3 2 3 3 2 3 b3.125 H,I,J,K,L 111 111 2 2222233 'ZI2 333344 3344443344443344554 354 554364 AM 2 2 2 2 2 2 3 2 2 3 2 3 3 2 3 3 2 2 3 2 3 3 2 3 1 1 1 1 11112121212 21213 131313131314 4 3 3 4 4 4 4 3 3 4 4 4 4 3 3 4 4 5 4 4 3 5 4 5 4 4 3 5 4 INOCNANGES7MSHEET PA.8QX 76� - - � --�-- --- NOKOMIs. FL91Z/4 V4ib(y Better sH70o NTS 9 • 11 ANCHORAGE NOTES: 1. ANCHOR TYPES: 1-1/4" ELCO TAPCONS 2 -1/4' ELCO S84 CRETE-FLEX ® 3-#12 SCREWS 2. ANCHOR LOCATIONS ARE BASED ON THE FOLLOWING DIMENSIONS: HEAD-181/2' MAX. FROM TOP CORNERS JAMBS-171/2" MAX, FROM TOP CORNERS 15" MAX. FROM BOTTOM CORNERS 6' MAX BELOW MTG. RAIL ®SILL •ANCHORS NOT REQUIRED 3. INSTALL PER THE ADJACENT TABLE ANCHOR QUANTITIES USING THE DIMENSIONAL CRITERIA OF ®NOTE 2. 4. TABLE WIDTH AND HEIGHT DIMENSION ARE FOR FLANGED WINDOWS. INTEGRAL FIN DIMENSIONS ®ARE 1"LESS. 5. DESIGN PRESSURE LIMITATIONS: SIZE BLOCKS OF THE ADJACENT TABLE WITH A BOLD ITALICIZED VALUE ABOVE THEM, INDICATE MAXIMUM DESIGN PRESSURE WITH THE QUANTITY OF ANCHORS SHOWN IN BOLD. OTHERWISE, THE MAXIMUUM DESIGN PRESSRE FOR TH RESPECTIVE SIZE AND GLASS TYPE IS AVAILABLE. A TABLE KEY: MAX. P MTG. RAIL JAMB BELOW MTG. RAIL JAMB ABOVE 2 2 �20� •��ENSF '�' MTG. RAIL `: O6 JAMB BELOW N •'* *: o MTG. RAIL = (0 0 l O•••. g1AT OF r '; p �� Off. ••,• FLOR�Q�'' •C1 F '�, SNNSIONP� A. LYMILL�I1; P.E. DARD VIEW W, IMPACT vw w. 4040M D FL P.E.B 68705 ANCHOR QUANTITIES ABOVE MEETING RAIL HEAD & JAMBS1 CUSTOM FLANGED WINDOW HEIGHT MINUS SASH HEIGHT TABLE 7. WINDOW HEIGHT MINUS SASH HEIGHT FROM TABLE 8. SUBSTRATE: 17.125 22.668 28.211 33.54 1 39.296 44.839 50,382 65.925 ANCHOR TYPE: CIO NV�vc-T Qo 0 0 0 1`�SNU�ON$zm po 0 O o 0 NO'UN5N�'UN5N�'ONSNV�UN�$N0 U go c� O zmo og c) U oQ U 0 o 0 U 0 W WIWINDTH GLASSN TYPE 19.125 D.E,F.J, K L 1 _._.. 1 1 __---- 1 1 1 1 --- 2 1 -- 2 1 --'-- 2 1 ---- 2 1 ---- 2 1 -- 2 1 2 1 2 1 2 1 2 1 2 1 2 1 3 1 2 1 3 1 3 1 2 1 3 1 3 1 -._... 3 1 ___. 3 24.000 D,E.F,J,-'�---.1_�...-'1---1-'--.�_. K,L 1 1 1 2 2 2 2 2 2 2 2 3 3 2 3 3 2 3 3 3 3 3 3 4 32.000 O.E F,J, K,L . 1 9 _ 1 1 1 1 1 2 1_ 2 1 2 2 3 1 2 1 3 2 8 1 3 1 3 '--3 1_ -1-- _- 1 _- 1 3 1 4 3 4 ...4. 3 4 5 3 5 PSF 79 37.000 D.E.F,J. K,L 1 1 1 1- 1 1- 2 2 1 2 2 2 2 3 1 2 2 3 2 3 1 3 2 4 2 3 1 3 2 3 2 4 1 3 2 4 2 4 1 4 2 6 2_ 5 1 4 2_ 5 PSF 79 79 79 79 40.000 D,E,F,A 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 1 2 2 2 2 2 2 2 K.L 1 1 1 2 2 2 3 3 3 4 1 3 4 4 1 3 1 4 4 3 6 4 4 5 5 4 6 PSF 79 76 79 1 77 1 79 79 79 44.0D0 D,E.F,J, 2 2 2 2 2 2 2 2 2_ 2 2 2 2 2 2 2 2 2 2 2 2K,L 1 1 1 2 2 2 3 3 4 4 4 3 5 4 3 6 5 4 6 5 4 6 PSF 78 79 70 79 79 71 79 76 48.000 DE,F,J, 2 2 2 2 2 2 2 2 2 2 2 2 2 3 2 2 K,L 1 1 1 2 2 2 3 3 f22 4 4 5 4 b 5 4 8 6 4 8 6 8 8 PSF 71 78 83 71 79 64 74 69 53.125 D,EFJ, 2 2 2 2 2 2 3 22 3 3 2 3 3 2 3 3 2_ 3 3 2_ 3 K,L 1 11 2 2 2 3 34 4 '5 4 5 8 6 8 8 5 7 8 5 7 ANCHOR QUANTITIES AT JAMBS BELOW MEETING RAIL, CUSTOM FLANGED WINDOWS BASED ON SASH HT. TABLES. SASH HEIGHT SUBSTRATE. 12.776 16.776 1 18.776 21.776 2A.776 27.776 30.776 31.106 ANCHOR TYPE. o N of N oD U^ o t..lN N 0D N 8'$t+/ p� oQ N $ N p U' p °0 c7§ . Q N U e oo fiN N N (ZOO U'UN$ �p QQ� N Q (7' cp1 U�$ QQo N Qu v' po N Zq0 0 WINDOW WIDTH 18.125 1 1 1 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Z 2 24.000 2 1 1 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 3 2 2 3 2 2 32.000 2 1 2 2 2 2 3 2 2 3 2 3 3 2 3 3 2 3 4 2 3- 4 2 1 3 79 37.000 2 1 2 2 2 2 3 2 3 3 2 3 3 1 3 1 3 3 3 3 4 3 3 4 3 4 74 40.000 2 2 2 2 2 2 3 2 3 3 2 3 3 3 3 4 3 3 4 3 4 4 3 4 68 78 44.000 2 T 2 2 2 2 2 3 2 3 3 3 3 4 1 3 1 3 4 3 4 5 3 A 5 3 4 63 72 79 48.000 2 2 2 3 2 3 —WW2�2 4 3 3 .4 3 4 4 3 4 5 3 4 5 58 88 72 53.125 2 2 2 3 3 1 3 1 4 3 1 4 1 4 1 3 1 4 1 b 1 3 1, 41 5 1 3 1 5 1 5 1 3 1 5 ANCHORAGE NOTES: 1. ANCHOR TYPES: 1-114" ELCO TAPCONS 2 -1W ELCO 554 CRETE-FLEX 3 - #12 SCREWS 2. ANCHOR LOCATIONS ARE BASED ON THE FOLLOWING ® DIMENSIONS: HEAD-18112" MAX. FROM CORNERS JAMBS-17117' MAX. FROM TOP CORNERS 11 1/2" MAX. ABOVE THE MEETING RAIL 8" MAX BELOW MTG. RAIL 15" MAX FROM BOTTOM CORNERS SILL - ANCHORS NOT REQUIRED 3. DETERMINE THE ANHCOR QUANTITIES FOR CUSTOM ® VIEW WINDOWS FROM TABLES 7. AND S. USING THE DIMENSIONAL CRITERIA OF NOTE 2. USE TABLE 7. FOR ABOVE THE MEETING RAIL AND TABLE 8. FOR BELOW. A. AVAILABLE SASH HEIGHTS FOR CUSTOM VIEW ® WINDOWS ARE 12 518" MIN. TO 38" MAX. TABLE WIDTH AND HEIGHT DIMENSION ARE FOR FLANGED WINDOWS. INTEGRAL FIN DIMENSIONS ARE 1" LESS. 6, DESIGN PRESSURE LIMITATIONS: ® SIZE BLOCKS OF THE ADJACENT TABLE WITH A BOLD ITALICIZED VALUE ABOVE THEM, INDICATE A MAXIMUM DESIGN PRESSURE WITH THE QUANTITY OF ANCHORS SHOWN IN BOLD. OTHERWISE, THE MAXIMUM DESIGN PRESSURE FOR THE RESPECTIVE SIZE AND GLASS TYPE IS AVAILABLE. ® TABLE 7. KEY: MAX. PSF (DP 1110TED) 112 HEAD 2 JAMB ABOVE 2 MTG. RAIL (FULL DP) HEAD 2 JAMB ABOVE 4 MrG. RAIL ® TABLE 8. KEY: c Can1m1 MAX PSF oFm (DP LIMITED) 112 JAMB BELOW1 2 1ItUun i 4....,41144 MTG. RAIL .`� p0� FULL DIP) JAMB BELOW 2 Q 58705 = MTG, RAIL •k = G(o a •• ,OF CUSTOM VIEW ''O� S7pT ;' �� ' �'o�� •. FcoR1o? :aC�: - K —imaroe ._B dEb7SPiCdwit'i1�ri9irE�(Ar�Tdk'bii'r§ amrc7EoevsaEI rae� 163" I �, - - - grow . A. LYNNMILLVA; P.E. I I �; —7 nm, 11oKonita Fl.aus+ V"ly Bettor sumo NTS 10 + 11 4040.20 D FL P.E.# 68706 FK 7f1R/O6 Jd 21W77 eLl EXTERIOR INTERIOR ALL HEAD AND SILL DETAI ) ® CONCRETEANCHOR 3.35 KSI MIN. CONCRETE (SEE NOTE 1 & 3) ® 2x WOOD BUCK WOOD ANCHOR A(SEE NOTE 4) (SEE NOTE 2 & 3)® "� • 1 3/8' MIN., 114"TAPCON® .'; .1•.314"MIN.,1/4" CRETE•FLEX +" OPTIONAL 1x o - _M WOOD BUCK (SEE NOTE 4) va• 114' MAX MAX SHIM SHIM DETAIL A DETAIL B TYPICAL FLANGED HEAD ANCHORAGE 1 3/8' MIN. r 1 114' 114• MAXSHIM MAN. 114" MAX. CONCRETE ANCHOR, FH BELOW MEETING A' RAIL. (SEE NOTE 1 & 3) �• 335 KSI MIN. CONCRETE ,•r„i OR 1.6 KSI MIN. CMU® 1x BUCK OPTIONAL WITH SOLID CONCRETE SUBSTRATE (SEE NOTE 4)® DETAIL C 131" DIA. M x211VW AT CORNE AND 5' C 1. FOR CONCRETE APPLICATIONS IN MIAMI•DADE COUNTY, USE ONLY MIAMI-DADE COUNTY APPROVED 1/4' ELCO TAPCONS OR IW SS4 CRETE-FLEX. MINIMUM DISTANCE FROM ANCHOR TO CONCRETE EDGE IS 1 3W. 2. FOR WOOD APPLICATIONS IN MIAMI-DADE COUNTY, USE #12 STEEL SCREWS (GS) OR 1/4• SS4 CRETE-FLEX. 3. FLAT HEAD ANCHORS, WHERE REQUIRED, MUST 14AVE#12 TRIMFIT HEADS. 4. WOOD BUCKS DEPICTED IN THE SECTIONS ON THIS PAGE AS 1x ARE BUCKS WHOSE TOTAL THICKNESS IS LESS THAN 1 112". 1x WOOD BUCKS ARE OPTIONAL IF UNIT CAN BE INSTALLED DIRECTLY TO SOLD CONCRETE. WOOD BUCKS DEPICTED AS 2x ARE 112" THICK OR GREATER. INSTALLATION TO THE SUBSTRATE OF WOOD BUCKS TO BE ENGINEERED BY OTHERS OR AS APPROVED BY AUTHORITY HAVING JURISDICTION,. S. FOR ATTACHMENT TO ALUMINUM: THE MATERIAL SHALL BE A MINIMUM STRENGTH OF 6063-T6 AND A MINIMUM OF 118• THICK. THE ALUMINUM STRUCTURAL MEMBER SHALL BE OF A SIZE TO PROVIDE FULL SUPPORT TO THE WINDOW FRAME SIMILAR TO THAT SHOWN IN THESE DETAILS FOR 2x WOOD BUCKS. THE ANCHOR SHALL BE A#12 SHEET METAL SCREW WITH FULL ENGAGEMENT INTO THE ALUMINUM. IF THESE CRITERIA ARE MET, THE RESPECTIVE DESIGN PRESSURES AND ANCHORAGE SPACING FOR TAPCONS MAYBE USED. A FLANGED FRAME COMPONENT MAYBE SUBSTITUTED FOR AN INTEGRAL FIN FRAME COMPONENT FOR MULLED APPLICATIONS. FOR INTEGRAL FIN MULLED APPLICATIONS IT IS EXCEPTABLE TO REMOVE THE FIN AND ATTACH TO THE MULL THROUGH THE FRAME USING THE FLANGED FRAME ANCHORAGE REQUIREMENT, 6. ANCHORS ARE NOT REQUIRED AT THE SILL OF FLANGED UNITS. 7, MATERIALS, INCLUDING BUT NOT LIMITED TO STEEL SCREWS, THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OFFBC CURRENT, EDITION, SECTION 2003.8A (SUPPLEMENT 2005). WOOD ANCHOR, FH BELOW MEETING RAIL.(SEENOTE2&3) INTERIOR (ALL JAMB DETAILS) EXTERIOR 2x WOOD BUCK (SEE NOTE 4)® DETAIL D TYPICAL FLANGED JAMB ANCHORAGE AN E'J; vm DETAIL F, (HEAD) va MAX. I �— SHIM I pm, WOOD FRAME FRAME� .131' DIA. MIN. x 2112' NAIL, AT CORNERS AND 6" O.C. . x 2112' NAIL, AT CORNERS AND W O.C. DETAIL E, (JAMB) TYPICAL INTEGRAL FIN ANCHORAGE DETAILDETAIL G, (SILL) P.O NOXMIS, R. MV4 VLIb(y 8st4r �` smso NTS H • N 1/4" MAX. SHIM FRAME LYNN M11le i,�' 68105 ' "O lu ' 'p F ''' �s1Aff€o IMPACT A. LYNNMILLiA, P.E. 4040,20 D FL P.E.A' 58705 MIAMFlaADE MIAMI—DADE COUNTY, FLORIDA DUCT CONTROL SECTION '1 1805 SW 26 Street, Room 208 DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGU AFFAIRS (PERA) M —Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION 4`p 6)315-2599 NOTICE OF ACCEPTANCE (NOA) ,amiila eioy/6erat PGT Industries q1M, 1070 Technology Drive Nokomis,.Fl 34275 VA SCOPE: This NOA is being issued under the applicable rules and regulations governing the us, uction materials. The documentation submitted has been reviewed and accepted by Miami Dade Co{tnty` PERA- Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series "PW-701" Aluminum Fixed Window - L.M.I. APPROVAL DOCUMENT: Drawing No. 4259-4 titled "Aluminum Picture Window, Impact", sheets I through 8 of 8, prepared by manufacturer, dated 07/14/03 with revision "D" dated 10/18/11, signed and sealed by Anthony Lynn Miller, P. E., bearing the -Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and Expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant. LABELING: Each unit shall bear a permanent label with the manufacturer's name or to' state, go, city, model/ series and following statement: "Miami -Dade County Product Control Approved" unless otherwise noted herein. RENEWAL of this ' NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance, of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT; The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may I be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at ' the request of the Building Official. This NOA revises NOA No. 10-0504.05 and consists of this page 1, evidence pages E-1 and E-2, as well as approval document mentioned above. The submitted documentation was reviewed by Jaime D. Gascon, P. E. NOA No. 11-1110.15 Expiration Date: February 19,2014 Approval Date: February 02,2012 Page 1 PGT Industries NOTICE OF ACCEPTANCE: " EVIDENCE SUBMITTED A. DRAWINGS ` . 1. Manufacturer's die drawings and sections. (Submitted under previous NOA No. 03-1105.01) 2. Drawing .No. 4259-4 titled "Aluminum Picture Window, Impact", sheets 1 through 8 of 8; prepared by manufacturer, dated 07/14/03 with revision "D" dated 10/18/1 f, signed and sealed by Anthony Lynn Miller, P. E. B. TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203 94 along with marked -up drawings and installation diagram of aluminum fixed window, prepared by Fenestration Testing Laboratory, Inc., Test Reports No.'s FTL-3835 and FTL--3850, dated 07/18 and 31103, all signed and sealed by Joseph C. Chan, P. E. (Submitted under previous NOA No. 03 1105.01) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, dated 08/19/10 complying with FBC-2007, prepared by manufacture, signed and sealed by Anthony L. Miller, P. E. (Submitted under previous-NOA No. 10-0504 05) 2. Glazing complies with ASTM E1300-02/ 04 D. QUALITY ASSURANCE 1. Miami -Dade Department of Permitting, Environment, and Regulatory Affairs (PERA) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 11-0325.05 issued to Solutia, Inc, for their "Saflex -- Clear or colored Interlayer" dated 04/21/11, expiring on 04/21/16, 2. Notice of Acceptance No. 11- 0624.01 issued to E. I. DuPont DeNemours & Co., Inc. for their "DuPont Butacite® PVB Interlayer" dated 09/08/11, expiring on 12/11/16. F. STATEMENTS 1. Statement, letter of conformance and compliance with the FBC-2007 (with the 2009 supplement) and FBC-2010, dated 10/29/11, signed and sealed by Anthony Lynn Miller, P. E. 2: Statement letter of no financial interest and independence, dated 10/29/11, signed and sealed by Anthony Lynn Miller, P. E. 9"- �:�- Jaime D. Gascon, P. E. Product Control Section Supervisor NOA No. 11-1110.15 Expiration Date: February 19, 2014 Approval Date: February 02, 2012 E-1 PGT Industries NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED F. STATEMENTS 3. Letter of Adoption of as his Own, the Work of another Engineer per Section 61G15 27.001 of the F.B.P.E., dated 08/19/10 signed and sealed by Anthony Lynn Miller, P. E. . (Submitted under previous NOA No.10-0504.08) 4. Statement letter of conformance and compliance with the Florida Building Code, dated 08/19/10 signed and sealed by Anthony Lynn Miller, P. E. (Submitted under previous NOA No.10-0504.08) 5. Statement letter of no financial interest and -independence, dated 08/19/10 signed and sealed by Anthony Lynn Miller, P. E. (Submitted under previous NOA No. 10-0504. 08) 6. Laboratory compliance letter for Test Reports No.'s FTL-3835 and FTL-3850, issued by Fenestration Testing Laboratory, Inc., dated 07/31/03, signed and sealed by Joseph C. Chan, P. E. (Submitted under previous NOA No. 03-1105.01) G. OTHERS 1. Notice of Acceptance No. 10-0504.05, issued to PGT Industries for their Series "PW- 701 Aluminum Fixed Window - L.M.I." approved on 09/22/10 and expiring on 02/19/14. Jaime D. Gascon, . E. Product Control Section Supervisor NOA No.11-1110.15 Expiration Date: February 19, 2014 Approval Date: February 02, 2012 E-2 NOTES: SERIES 701 ALUMINUM FIXED WINDOW 1. DIRECTIONS FOR USE: A. DETERMINE THE PRODUCT'S MAXIMUM DESIGN PRESSURE FROM EITHER TABLES ON SHEET 2 (DEPENDING ON YOUR GLASS TPE). B. DETERMINE THE TYPE AND QUANTITY OF ANCHORS REQUIRED TO MEET THE WINDOWS DESIGN PRESSURE FROM SHEET 6 FOR WOOD SUBSTRATES, OR SHEET 7 FOR MASONRY SUBSTRATES. SPACE ANCHORS APART EQUALLY PER NOTES ON SHEET. C. USE SHEETS 3 THROUGH 6 TO INSTALL PRODUCT, REFERENCING NOTES FROM SHEETS 6 & 7. 2. DESIGN PRESSURE RATINGS: NEGATIVE DESIGN LOADS 114SED ON TESTED PRESSURE AND ASTM E1300-02, 3-SECOND GUST. POSRNE DESIGN LOADS BASED ON WATER TEST PRESSURE AND ASTM E1300-02, 3-SECOND GUST. 3. ANCHORAGE: THE 33-1/39 STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT. MATERIALS, INCLUDING BUT NOT LIMITED TO STEEL, SCREWS, THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE FLORIDA BUILDING CODE. LOAD DURATION, Co. OF 1.6 WAS USED IN WOOD SUBSTRATES ONLY. 4. SNLITIER REQUIREMENT: NONE REQUIRED 5. MATERIALS USED FOR ANCHOR EVALUATIONS WERE SOUTHERN PINE, C-90 CONCRETE MASONRY UNITS AND CONCRETE WITH MIN. KSI PER ANCHOR TYPE, SEE SHEET 7. S. REFERENCES: TEST REPORTS. FrL-3835 & FTL-3850, NGA: 07-0425.01 (ULTRACON), 03-0225.05 (CRETE-FLEX), ANSI/AF&PA NDS-2005 FOR WOOD CONSTRUCTION, ADM-2005 ALUMINUM DESIGN MANUAL 7. THIS PRODUCT HAS BEEN DESIGNED & TESTED TO COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE, INCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ). 8. SHIMS ARE REQUIRED AT EACH ANCHOR LOCATION WHERE THE PRODUCT IS NOT FLUSH TO THE SUBSTRATE. USE SHIMS CAPABLE OF TRANSFERRING APPLIED LOADS. WOOD BUCKS, BY OTHERS, MUST BE SUFFICIENTLY ANCHORED TO RESIST LOADS IMPOSED ON THEM BY THE WINDOW. 9. NARROW JOINT SEALANT IS USED ON ALL FOUR CORNERS OF THE FRAME. INSTALLATION ANCHORS SHOULD BE SEALED 44-1/4' 45-1/4" VISIBLE LIGHT WSIBLE LIGHT 6' 12-7/8" MAX. g MAX. O.C. C C A A 98 1/4' I FIN ND 1 92-1/4" 5" T L V M. 1 \\ UGHT 93-1/4" GN1 D.C.AX\\ VISIBLE 96, ucHr 12-7/e' FIANCE 96, MAX. FLANGE L[ I I NOA DRAWING TABLE OF CONTENTS GENERAL NOTES........................I ELEVATIONS, FLANGEO...............1 ELEVATIONS, INTEGRAL FIN....... 1 GLAZING DErAILS.......................2 DESIGN PRESSURES, FLANGED. 2 DESIGN PRESSURES, FINNED....2 INSTALLATION, INTEGRAL FIN.....3 CORNER ASSY, INTEGRAL FIN..3 INSTALLATION, FLANGED ....._......4 CORNER ASSY, FLANGED......... 4 INSTALLATION, MISC.................. 5 ANCHORAGE ............................... 8,7 EXTRUSION PROFILES................8 PARTS LIST... I............................8 MAX. , 0 FLANGE 2' MAX. J 48' Ll—� TOFIN 1/4' TYR FLANGED FRAME ELEVATION TYP. INTEGRAL FIN FRAME ELEVATION (TESTED UNIT1 (TESTED UNITi ADHESIVE SEALANT SHALL BE USED BETWEEN SUBSTRATE AND OTHER SHAPES AS SHOWN BELOW OR SIMILAR, MAY BE USED BY FLANGE OR FIN. OVERALL SEALING/FLASHING STRATEGY FOR INSCRIBING THE SHAPE IN A BLOCK AND OBTAINING DESIGN PRESSURES WATER RESISTANCE OF INSTALLATION SHALL BE DONE 13Y FOR THAT BLOCK SIZE FROM THE TABLES ON SHEET 2. PRODUCI'RHVIS® f�— WIDTH --1 t mXN17Lu9WM,enl7mida WIDTH —�i� H — WIDTH q�saealmpp mNo I l.fJJJ9 -o� WIDTH --i WIDTH F+-I WIDTH F- i � i Minim edo FYR q T F+— WIDTH --4 WIDTH --•I F•"- WIDTH + 1-- WIDTH - H F— WIDTH —I b T T Tr T T �oNy LYNN AA�� �i. 13 P r2 .`l'ri' GENSB L L .� � 1 1 L J j- � �*• N0 .58T65 '., Y R 9 q J.J. I0/18 11 D 2010 fHC VPG4TE %� '•. -STA O L E // AnGN 1ma TEOHNOLOGY D ELEVATIONS AND NOTES �.P'•. F(0RID7:♦.'�`C9=� J.R. J 31 f0 C INFO ON FOR LING WS. M VENICE. R 34273 '�i �s "••....••' 4` `� TE RE . 1 Q-D2 RLYIs ALUMINUM PICTURE WINDOW, IMPACT F.K. 4 4 07 B ANLT'iORAGE iF J. P.O. BOX 1629 _ m NOKOMIS, FL 34274 V/AP( YM Y•E, FX 7H4NJ naM TK701 NTS �: e 8 4.%4 D. P.E.L 58705 Fin end Flanged Maximum Deelgn ,Af wm18n4i-A90PV3-31/016 Pre66Mre (+!-peQ ,/ae 1m416i9n6RAP•,nBNP•3niA-A90aY0.3AN8 24 30 3B 42 48 1 54 60 67.875 38 80.0 60.0 'me 80.0' 80.0 80.0 60.0 80.0 48 60.0 80.0 80.0 80.0 MO BGO MD 80.0 8D 60.0 Sao me 60.0 80.0 71.1 71.1 64.0 u 67.876 80.0 no 80.0 MO 60.0 71.1 84.0 621 F 72 no 80.0 80.0 Sao 7R3 71.1 64.0 •aE��l 76.8 80.0 80.0 80.0 80.0 76.0 70.0 04.0 84 BOLO MO 80.0 74.3 88.3 83.6 a 85.3 80.0 80.0 60.0 73.6. 47.4 6Z6 b 88 100.7 80.0 80.0 80.0 60.0 77.2 'a3 64.7 58.3 68.2 120 80.0 80.0 70.4 128 60.0 600 70.0 116 80.0 8D.0 Flo end Fwmw W01d0W'4 Maximum Design 7lr4M.a�3nels•A33Fv4anNn Pressure (+-peQ 714ledle3AA 71MAal•7AGI!I alwe.snsHs A'Of"B D IOn(IB 24 30 38 1 42 48 84 60 07.076 38 me no 80.0 80.0 60.0 me 60.0 no 48 BOLA no 80.0 Sao 80.0 BOA 80.0 Sao DD me 80.0 80.0 80.0 00.0 71.1 71.1 64.0 07.878 80.0 no 80.0 MO 80.0 71.1 "0 o21 72 80.0 BO.O MO 60.0 MO 71.1 64.0 76.8 00.0 80.0 80.0 80.0 00 71.1 64.0 84 MO 80.0 60.0 80.0 BI 71.1 85.3 BOB SOLO 60.0 BOLO 80.0 71.1 b BB 80.0 80.0 BD.O 80.0 80.0 108.7 60.0 80.0 80.0 me 12D 60.0 BOLD 80.0 128 80.0 6" 80.0 1. 80.0 no 7/19• 1- G ROa®41L Ago• 0UP0111 Bufaffl[ oA 3/13' AwALu, OR m, .Rnanw- olAiS WIW 1FA MIN J/la' N I1 RCRQIMOtm C1A53 'B' DIM. A' h DIMENSIONS MAY BE ORIENTED VEfi11CALLY OR " 10 17 21 HORIZONTALLY AS SHOWN. OOFJ>dH I I5 I+- 'B' DIM. -.•i \ 'B' D DIM. U� .-. 13 2 7/16" LAMI GLAZING DETAIL FLANGED OR INTEGRAL FIN FRAME (FLANGE FRAME SHOWN) 7/IO' uaa CVss NOMMK 1-I/I6' VNI CUSS N01MUL A30- OtnP WTA OR 7/1a• M sTAca � c euttMw 3/la•.WxFNip OR 16AT NlmlaleVAtO awsle• xra J/le' mvoav 4TA49 RFM0111FNfD CIAO n/la - w,ss mn: 1-1/16" LAMI I.G. GLAZING DETAIL FLANGED OR INTEGRAL FIN FRAME NOTES; (INTEGRAL FIN FRAME SHOWN) 1. ANY ONE S10E OF THE WINDOW CANNOT BE MORE THAN 145' NOR CAN THE: WINDOW AREA EXCEED 32FT'. 2. FOR SIZES NOT SHOWN. ROUND .UE TO THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION. 3. FOR ARCHITECTURAL WINDOWS. FIND THE SMALLEST WINDOW SIZE IN THE TABLE ABOVE WHICH THE OVERALL WIDTH AND HEIGHT DIMENSIONS COMPLETELY FITWITHIN. 4. THE WINDOWS WIDTH AND HEIGHT (DIMENSIONS -A- AND 'n MAY BE REVERSED TO OBTAIN A MORE ACCURATE RESULT FROM THE TABLE (SEE FIGURE, THIS SHEET). NO P.O. BOX 7529 NOXOMIS. FL 34274 iLUmaIVUMr-AirU=YVITYUUW MyyIMI"Fll 1> RYf01 zs 2 + e 4n&4 uCENSg '•;y�'� N., 58705 � ST 7E F �ll.W;, A PE.�d587U5P.E. INSTALLATION DETAILS FOR FINNED FRAMES 2X WOODBUCKAMING OR �— 1/4" MAX. SHIM 1/4' MAX. SHIM -+1 ZX WOOD BUCK OR FRAMNG SEE ANCHOR • GUIDELINES, 1 13 SHEET 5 1 13 INTERIOR 375' MIN, 2X WOOD BUCK OR FRAMING EDGE DISTANCE .131' (1/8') X 2-1/2" NAIL. WITHIN 2' OF .131' (1/8') 1-3/6' MIN. CORNERS AND 5' D.C.. X 2-1/2' NAR, EMBEDMENT 11 .375' MIN. 1 EDGE DISTANCE WITHIN 2' OF CORNERS AND 5' O.C. 11 1B a8O fl O 10 MAX, VISIBLE OPEN[N 13 OW MAX. WINDOW HEIGHT HORIZONTAL SECTION C—C MAX. WINDOW HEIGHT MAX VISIBLEVISIBLE ucHN OPENING 18 22 17 21 1N�Lv& SEE ANCHOR GUIDELINES, SHEET 8 13 10 1 rMAX. EXTERIOR SHIM 1 3/8' MIN. EXTERIOR EMBEDMENT MITERED FRAME WNW INTERIOR 2X WOOD BUCK AND EXTERIOR FRAME WELDS SHEET 6 (SHOWN) OR CORNER KEYS AT OR FRAMING SCREW BOSSES VERTICAL SECTION D—D PRODUCT REVISED O e°°WlYinpxlW Ih° FIaACa BcmpI N ('(•1 90°CORNER ASSEMBLY ANGLED CORNER ASSEMBLY ^°N° 04 NOTES 1. USE ONLY NAILS PER ABOVE, OR ANCHORS LISTED ON SHEET 6. FOLLOW EMBEDMENT AND EDGE DISTANCE LIMITS. 111 � '��;•'VCEN$F �;F.p �'ii *' N°. 58105 Euz id..E-7/14w D NO CRANCE THIS SHEET ,,j F MINSTALLATION FINNED FRAMEINCLUDE �or:,.• sTnrEG '�1U� J.R. C / fDRMATON LAR ER WN00)IM 0N.0 1VEMCE, R J9275 S •.�OR...... :� P.M BQX 1528 ALLIMINUMPICTUREWINDOW, IMPACT �SIONAI-E G NDKDMIS, FL J9274 T'�" "° x°n ,°i A {LhhI TMLar, P.E. F.m4 PX�7N NTS'3 a 8 4259.4 D tf�3 E.d M705 INSTALLATION DETAILS FOR FLANGED FRAMES SEE ANCHOR 1X WOOD BUCK 1/4' MAX. SHIM GUIDELINES, SEE ANCHOR SHEET 7 1/4' MAX. SHIM GUIDELINES, —2% WOOD BUCK OR FRAMING MIN. CONCRETEPER I 2 SH 6 T3 2 SEE ANCHOR ANCHOR 1TYPE,--' f gEQg .-13 GUIDELINES, MIN. CONCRETE K51 SEE SHEET 7 SHEET 7 PER ANCHOR TYPE, 5. SHEET OR 1.5 KSI EE AN 7. OR 1.5 KSI MIN. CMU MIN. CMU 3UIDELINES, 1X WOOD BUCK SHEEP 7 1/4" MAX. SHIM 1T SEE CUI ANCHOR N 18 RO 17 aR 21 10 SEE ANCHOR SHEET 7 GUIDELINES, 13 SHEET 8 MAX. WINDOW HEIGHT HORIZONTAL SECTION A -A MAX. 1B oRO WINDOW HEIGHT 17 21 MA% VISIBLE OPENM.G UGHT INTERIOR _ II `ram I BOB!C ' Lzx WOOD BUCK OR FRAMING VERTICAL SECTION B-B EMERIOR KMITERED FRAME WITH INTERIOR PNO EXTERIOR FRAME WELDS (SHOWN) OR CORNER KEYS AT SCREW BOSSES ANGLED CORNER.ASSEMBLY NOTE 1. USE ONLY ANCHORS LISTED ON SHEETS 6 AND 7. FOLLOW EMBEDMENT AND EDGE DISTANCE LIMITS, Illlf LYNN 2. WOOD BUCKS DEPICTED IN THE SECTIONS ON THIS PAGE AS 1X ARE BUCKS WHOSE TOTAL THICKNESS IS LESS THAN 1-1/2", 1X WOOD 1y` :�(t;,�% BUCKS ARE OPTIONAL IF UNIT CAN BE INSTALLED DIRECTLY TO SOLID CONCRETE. WOOD BUCKS DEPICTED AS 2X ARE 1-1/2' THICK OR `.:'VGEN3F -r GREATER. INSTALLATION TO THE SUBSTRATE OF WOOD BUCKS TO BE ENGINEERED BY OTHERS OR AS APPROVED BY AUTHORITY HAVING JURISDICTION. *+ N.. 58705 ' J.J. TD 18 11 D"""' NO CHANGE THIS SHEET '�0.'•, STATA E'T OF J.R. to vlO C INFORMAIIO FOR LZZ N WS.NON 1. INCLUDE 1070 TECHNOLOGYE. FL DRRS INSTALLATION, FLANGED FRAME P.O. BOX 1529 ALUM/NUMPICTURE W/NDOW, IMPACT 'c�SIIOJNAI.,`E Gam. p"y; NOXOMIS, FL 34274 tl d' °'"'°" a* A. LIT,1�i 1MIiIW, P.E F.H. 7/14M PW-701 NTS 4 r B 42594 D P.Ej 68705 MISC INSTALLATION DETAILS SEE ANCHOR GUIDELINES, FIN FRAME WITH SHEET 6 FIN REMOVED INTERIOR 1/4' MAX. 1 SHIM 1 3/B' MIN. EMBEDMENT 2X WOOD BUCK OR FRAMING EQUAL LEG FRAME (OTHER FRAMES SW 2X WOOD SUBSTRATE Q12 STEEL 1/e' NOM. MIN. SELF —DRILLING SMS (GS) USE SAME ANCHOR DUANTITY & SPACING AS #12 STEEL SCREW EXTERIOR (SHE 6) DADE APPROVED MULLION (SEE SEPERATE N0 ALUMINUM: 6063—T6 MIN. .125' MIN. WALL THICKNESS FLANGE FRAME (OTHER FRAMES SIM.) ALUMINUM MULL SUBSTRATE SEE ANCHOR SEE ANCHOR GUIDELINES, GUIDELINES, FIN FRAME WITH SHEET 7 FIN FRAME WITH SHEET 7 FIN REMOVED FIN REMOVED :TERIOR INTERIOR 1R WOOD BUCK 1/4' 1/4' MAX. 1 SHIM SHIM SEE ANCHOR �::. :''� SHEET 7 GUIDELINES,:+'�.•., SHEET MIN. CONCRETE KSI PER ANCHOR, SEE SHEET 7 MIN. CONCRETE KSI PER ANCHOR TYPE, OR 1.5 KSI MIN, CMU SEE SHEET 7 OR 1.5 KSI MIN. CMU EQUAL LEG FRAME EQUAL LEG FRAM (OTHER FRAMES SIM.) (OTHER FRAMES SIM.) 1X WOOD BUCKSTRIP DIRECTLY TO MASONRY SEE ANCHOR GUIDELINES, SHEET 7 Q: 1CliER1OR 1/4' MAX. SHIM ANCHOR ,•,. �c..v� ' DE11NE5, MIN —CONCRETE KSI ' PER ANCHOR, SEE SHEET 7 OR 1.5 KSI MIN. CMU FLANGE FRAME PRECAST SLOPED SILL 1-3/e' MIN. 1/4" MAX. SHIM --r{ �+-- 1/4` MAX SHIM EMBEOi.1FNT 2% WOOD BACKER 1/4' MAX. SHIM If EXCLUDING POINT #12 STEEL 1/8' NOM. MIN. #12 STEEL #12 STEM ELF —DRILLING SELF —DRILLING SELF—DRILUNG SMS (G5) SMS (GS) SMS (05) USE SAME USE SAME USE SAME ANCHOR ANCHOR ANCHOR QUANTITY & QUANTITY. QUANTITY i4 SPACING AS SPACING &EDGE SPACING AS ®12 STEEL DISTANCE AS 012 STEEL SCREW EXTERIOR 812 STEEL EXTERIOR SCREW f EXTERIOR (SHEET 6) METAL FRAMING (SHCEET 9) REW FULL—LENGTH, W000 (SHEET 6) A35 STEEL: Fy-36 KSI MIN. BACKED STEEL STUD STEEL STUD KSI .125' MIN. WALL THICKNESS ALL GAUGE THICKNESSES IS G4 MIN. FLANGE MIN. (ATTACHMENT BY OTHERS) FLANGE FRAME FLANGE FRAME FLANGE FRAME (OTHER FRAMES SIM (OTHER FRAMES SIM,I (OTHER FRAMES SIM.) STRUCTURAL STEEL SUBSTRATE STEEL STUD/WOOD SUBSTRATE STEEL STUD SUBSTRATE NOTES 1. USE ONLY ANCHORS LISTED ON SHEETS 6 AND 7. FOLLOW EMBEDMENT AND EDGE DISTANCE LIMITS. 2. WOOD BUCKS DEPICTED IN THE SECTIONS ON THIS PAGE AS 1X ARE BUCKS WHOSE TOTAL THICKNESS IS LESS THAN 1-1/2'. 1X WOOD BUCKS ARE OPTIONAL IF UNIT CAN BE INSTALLED DIRECTLY TO SOLID CONCRETE. WOOD BUCKS DEPICTED AS 2X ARE 1-1/2` THICK OR GREATER. INSTALLATION TO THE SUBSTRATE OF WOOD BUCKS TO BE ENGINEERED BY OTHERS OR AS APPROVED uy AUTHORITY HAVING JURISDICTION. 3. FOR ATTACHMENT TO METAL' THE STRUCTURAL MEMBER SHALL BE OF A SIZE TO PROVIDE FULL SUPPORT TO THE WINDOW FRAME. 4. IF APPLICABLE, LOWER DESIGN PRESSURE FROM EITHER WINDOW OR MULLION NOA APPLIES TO WHOLE SYSTEM. r J.J. lD%IB/If D NO CHANGE MIS SHEET * 1. 5B705 * �'• a `° u '� ` ••. STATE NDNDL95, Rf34Z74 eM,Wm+: urva:o w. 0. Lyrltl llL�lar, P.E. FJC 7%f4A73 f c PYKIT/l (1�T$ 6 H 8 4259-0 D P.E. 50705 Head, Sill and Jamb Anchor Quantities Into Wood or Metal (Anchor Types 1-4) Anchor TYPO 'A• or "B" Dimension Qn) 24 30 38 42 48 54 80 07.875 Anchor Location 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 38 Jamb 3 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 Head/SIO 2 2 2 2 3 3 3 3 4 3 4 3 6 4 6 4 6 5 6 6 6 6 6 6 0 a e e 7 6 7 8 4a Jamb 4 4 5 4 5 4 5 4 5 5 5 6 6 5 6 5 6 6 6 6 5 5 8 6 6 5 0 6 6 6 8 6 Hea"M 2 2 2 2 3 3 3 3 4 3 4 3 8 4 0 4 6 6 6 6 .6 0 7 8 8 6 7 6 7 7 8 7 Jamb 6 6 6 0 6 5 B 5 6 8 0 6 0 8 7 8 B 6 7 617 6 7 6 7 6 7 6 7 0 7 6 HeedlSill 2 2 2 2 9 3 3 9 4 3 4 3 6 4 5 4 6 6 8 b B 8 7 8 7 6 7 8 8 7 8 7 67.875 Jamb 8 6 7 8 7 6 7 6 7 6 7 0 7 7 8 7 7 7 8 7 7 7 8 7 8 7 B 7 8 7 8 7 Head1a81 2 2 2 2 3 3 3 3 4 3 4 3 6 4 6 4 5 5 8 5 6 6 7 6 7 6 7 8 8 7 8 7 72 Jamb 8 e 8 0 1 6 B 6 7 7 6 7 7 7 8 7 7 7 8 7 8 7 9 7 8 7 B 7 78.8 Head1S01 2 2 2 2 3 3 3 3 4 3 4 3 5 4 5 4 6 6 0 5 6 0 7 6 7 0 7 0 Jamb 7 7 8 7 8 7 8 7 8 7 a 7 8 8 8 8 a a a 8 8 B g e B B 8 B B5.3 90 1087 17B L128 145 Had/SN 2 2 2 2 3 3 3 3 4 3 4 3 5 4 5 4 5 6 0 6 6 0 7 0 7 (21. 7 8 9 8 8 8 9 B B B 10 8 9 a. 10 a 4 3 6 a 8 4 6 6 fi 6 86 7 6 9 8 8 a B a 8 8 10 a 9 a 10 8 4 3 5 4 5 4 6 6 6 b 0 8 7 0 10 B 9 9 10 9 B B 11191 4 3 8 4 5 4 5 5 8 M. 12 f0 f0 10 12 f0 4 3 5 4 6 4 13 11 ' Width and Height dimensions maybe 4 3 reversed to locate anchor quantities an the 4 3 table. If so, the Head/Sill and Jamb rows 4 3 mustalso be reversed so dimension getsthe most Jamb 7 7 B 7 e 7 8 7 8 8 HmNSill 2 2 2 2 3 3 3 1314 3 Jamb 7 7 B 7 8• 7 9 7 8 8 Headf3Y1 2 2 2 2 3 3 3 9 4 3 Jamb 8 8 10 8 9 8 10 0 8 B Head/810 2 2 2 12 3 3 3 3 4 3 Jamb 9 9 121 a 10 B 12 a 10 10 Head/S11 2 2 2 2 3 3 3 3 4 3 Jamb 10 10 13 1D 11 10 13 10 11 11 HeedlSlll 2 2 2 2 2 2 3 9 3 3 4 3 Jamb 11 11 12 11 13 11 12 12 HeadISW 2 2 2 2 3 3 3 3 4 3 Jamb 12 12 16 12 13 12 16 12 Head/501 2 2 2 2 3 3 3 9 NOTES: 1. ANY ONE SIDE OF THE WINDOW CANNOT BE MORE THAN 145' NOR CAN THE WINDOW AREA EXCEED 32FT'. 2. FOR SIZES NOT SHOWN, ROUND JIE TO THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION. 3. FOR ARCHITECTURAL WINDOWS, FIND THE SMALLEST WINDOW SIZE IN THE TABLE ABOVE WHICH THE OVERALL WIDTH AND HEIGHT DIMENSIONS COMPLETELY FIT WITHIN. 4. THE WINDOWS WIDTH AND HEIGHT (DIMENSIONS 'A' AND 'B7 MAY BE REVERSED TO OBTAIN A MORE ACCURATE RESULT FROM THE TABLE (SEE FIGURE, THIS SHEET). 5. DIFFERENT ANCHORS MAY BE CHOSEN FROM MULTIPLE TABLE COLUMNS TO MATCH THE SUBSTRATE. NeS Anehar TChayp. Anchor Description Substrate Min. Edge Dlsbmce Min Embed menl d/2, Steel ac,aw(G5) S. Plne_ 0.e84' 1.375' 1 Steel 6CrOW ( SU. Stud, Gr 33 0.324 .048./18Ga _A72. 012. Steel screw (G6� NM T. 60M:M ... 0,324 g12, Stall screw (G5) A38 Steel 0.324 Q72S 014. Steel screw(G5) S. Pine O.Bw 2 d14, Steel screw (GS) Su. Slud, Gr 33 0.361° _IzM .048'/18Ge #14, Steel screw (G5) _Alum. BOB3-TB 0.381' 0.126' 914, 8lwi screw (G A38 Steel 0.381' 0.125' 1/4' Steel Ultmcon so 1312 1°1,375' E 114. 410 SS CreteFle% _ S. Pine 1' 1.375' Wig• Steel Ultmcon S. Pine 1.28' 1.376' that the longer p' & N DIMENSIONS MAY alMhOrS. BE ORIENTED VERTICALLY OR HORIZONTALLY AS SHOWN. A' f ODA. BIN. —y \ \� "B° DIN. DL \\ NOKOMIS, R 392]{ ��� eaN"r — PW-70f NT$ 6 a 8 416!)d PBODUCFRSVISED caagdy4vllhrimPlah„la -Coeuol `l� ����1111111�j�� 1�%VCENaE '• i `* No. 50705 TA E F _ ]]f� i�hAuihal� P.L Head, Sill and Jamb Anchor Quantities Into Masonry (Anchor Types 6"7) Anchor Type 'A" cr'B' Dimenslon on) 24 30 1 38 1 42 1 48 1 64 1 6D 1 67.876 for Loca6on- 6 0 7 6 0 7 6 0 7 6 0 7 5 0 7 5 8 7 5 6 7 6 0 7 36 Jamb 3 4 4 3 4 4 3 4 4 3 4 4 8 4 4 3 4 4 3 4 4 3 HeadISlO 2 3 3 3 4 4 3 6 6 4 5 6 4 8 B 6 6 8 5 7 7 848 Jamb 4 5 5 4 5 6 4 0 6 6 6 6 5 6 6 5 8 6 5 8 6 6 Heaahl 2 3 3 3 4 4 3 5 6 4 0 5 5 7 6 6 7 a 6 g 7 7 60 Jamb j43 6 8 0 6 6 0 8 7 6 6 7 0 6 7 0 6 7 B 67 0 8HesdISIR 2 3 3 3 4 4 3 6 5 4 6 6 5 7 0 6 7 6 6 8 7 767676 Jamb 8 7 0 8 7 7 8. 8 7 7 8 7 7 8 7 7 8 7 7 8 8 7HesdlSH] 2 3 3 3 4 4 3 6 6 4 6 6 6 7 8 6 7 6 0 8 8 7 72 Jemb 8 6 8 8 7 6 B 7 8 8 7 7 9 7 7 9 7 7 B 8 7 7&B Head/SIII 2 2 2 3 3 3 4 4 3 6 b 4 8 5 51 7 1 6 6 7 8 6 8 'lob 8 7 7 B 7 7 8 8 7 8 8 8 9 a e 9 8 B B 8 E Head O'll 2 2 2 3 3 3 4 4 3 6 5 4 6 6 5 7 8 8 7 0 0 Jamb B 7 7 8 8 7 B 8 7 B 8 8 10 8 8 10 8 B C Hea61SM 2 2 2 3 3 3 4 4 3 5 5 4 8 5 5 Jamb 07 7 0 8 7 9 8 7 0$86.3Headl6111 9-6 109 7 120 1ze 145 2 2 2 3 3 3 4 4 3 6 6 4 8 6 6 81101 0 9 11 8 9 3 5 6 4 0 6 6 9 12 10 10 3 5 6 4 •Width and Height dimensions may 10 be reversed teloLatearchor 3 table, if so, the 11 quantities On and Head/Sill and Jamb rows mustalso 3 be reversed so that the longer dlmenslml gets the most anchors. Jamb 10 8 B 10 9 8 10 9 HeadlSIN 2 2 2 3 3 3 4 4 Jamb 12 9 9 12 10 9 12 10 HeadlSN 2 2 2 3 3 3 4 4 Jamb 13 10 10 13 11 10 13 11 Head/Sill 2 2 2 3 3 3 4 4 Jamb 13 11 11 13 12 11 13 12 Head/S®1 2 2 2 3 3 3 4 4 Jamb 16 12 1216 13 12 Head/S10 2 2 2 3 3 3 NOTES: 1, ANY ONE SIDE CANNOT BE MORE THAN 145' AND HAVE AN AREA OF MORE THAN 32171. 2. FOR SIZES NOT SHOWN, ROUND ME TO THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION. 3. FOR ARCHITECTURAL WINDOWS, FIND THE SMALLEST WINDOW SIZE IN THE TABLE ABOVE WHICH THE OVERALL WIDTH AND HEIGHT DIMENSIONS COMPLETELY FIT WITHIN. 4. THE WINDOWS WIDTH AND HEIGHT (DIMENSIONS "A* AND "87 MAY BE REVERSED TO OBTAIN A MORE ACCURATE RESULT FROM THE TABLE (SEE FIGURE, THIS SHEET). 5. DIFFERENT ANCHORS MAY BE CHOSEN FROM MULTIPLE TABLE COLUMNS TO MATCH THE SUBSTRATE. CWWCE THIS SHEET SHEET P.O. W 1529 NOKOma, FL 34274 Min. M M Anchor DeacApllon 8ubsbma Edge Embed• TypeAnchor Olatanoe mein 6 1/4' Stee!UlOwn Hollow Blodl 1' _ 114' Steel Ultraceo 2.7k Concrete 1" _ 1.376 8 1/4' 41D SS CmteFlex Hollow Block 1' 126' 1/4' 41D SS CreteFlox 3.351cConcrete _ 1' _ 1' 7 5110' Steel UBmcon HdMW Block 1.563'_ 1.217__ _ 6116' Steel Ullmcon &5k Concrete 1.25' _ t' "A' & "B" DIMENSIONS MAY BE ORIENTED VERTICALLY OR HORIZONTALLY AS SHOWN. 'A' I DIM. "8" DIM. --I \ I 'B' DIM. Di. \\ J M7e1 I IM 1 7 a 8 1 42594 PR0DUCTRBVTSED 9a� � mtho Flndds L� D � pp VOENSF '.'P . *' No.68705 STATE� " :'C� ............... 'G\�: 2.704• 094' 2.50D' III u-u }E' .Dn• �jII 1,1112*-mil I .11W 1.125" INTEGRAL FIN FRAME O MAT'L: 6063-T5 DWG NO. 4256A .094• 1.875' 1_ �- FOT� .062' z.7ea' FLANGED FRAMMAT'L: 6063-T5 O DWG NO. 4253 Imo-- .970' -1 I .050'-rT_{I•+- 7/16" LAMI GLASS BEAD 1a MAT'L: 6063-T5 DWG NO. 4255 .346' .975' I I .047. .050" 1-1/16" LA MI I.G. GLASS BEAD INSTALL. FASTENER COVER MAT'L: 6063-T5 73 MAT'L: 6063-T5 DWG NO. 4254 DWG NO. 4224 ITEM DWG# PART# DESCRIPTION 1 4255A 64256 Integral fin frame head, sill 8 jamb 2 4253 64253 Flanged frame head, s818 jamb 7 1155 781PDX #8 x 1 Quad PH SMS stalnless steel 8 Schnee -Morehead SM5504 acryl-r narrow joint sealant or 10 4255 64255 7/16 lami glass bead 11 4254 64254 14116 I.G. glass bead 12 1224 M247 Virryl bulb weatherstrip (thick) 13 4224 Installation fastener cover 14 Dow Corning 899 glazing sealant or equtualend 16 Dow Coming 995 silicone structural sealant, black 7116" Iemi glass 3116" annealed -.090 DuPont Butac@e or 17 Safiex KeWSafs Maximum PVB intetlayer- 3/16" heat strengthened 14116" laml I.G. glaaw 3/16" heat strengthened outboard - 18 7/W elrspace - 3116" annealed - .0W DuPont Butacite or Sallex KeepSale Maximum PVB intedayer- 3/16" heat strengthened 20 4252 64262 Architectural comer key 7116" laml glass 3/16" heat strengthened -.090 DuPont 21 Buteclte or Saflex KeepSafe Maximum PVB Intedayer- 3116" heat strengthened 14116" laml I.G. glass 3116" heat strengthened outboard - 22 7115' airspace - 3116' heat strengthened -.090 DuPCM Butscite or Saftex KeepSafe Maximum PVB intedayer - 3/16' heat strengthened r0 TECHNOLOGY OFM I EXTRUSION PROFILES A PARTS LIST I. VENICE, FL 34275 r.o. eox 1s2a ALUMlNUMPICTURE WINDOW, IMPAL N0xOw5. FL 34274 PynT IVTS I 8 m 8 1 4269-0 V N N 4f,,"/, 'l .'VGENa& �'k � • No. 68705 •• * ' •'•. STATE FI ; • _�` FORM 1100A-08 FLOR`aQA-ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Performance Method A Project Name: NOBLE RESIDENCE Builder Name: Street; Permit Office: City, State, Zip: FT. PIERCE, FL, Permit Number: Owner. Jurisdiction: Design Location: FL, Fort Pierce 1. New construction or existing New (From Plans) 9. Wall Types . Insulation Area -_2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=5.4 2424.50 ftz 3. Number of units, if multiple family 1 b. N/A R= ftzc. N/A R= ftz 4. -Number of Bedrooms 4 d. N/A R= ftz 5. Is this a worst case? No 10. Ceiling Types Insulation Area 6. _Conditioned floor area (ftz) 2618 a. Under Attic (Vented) R=19.0 2618.00 ftz 7. Windows Description Area b. WA R= ftz :a.: U-Factor. Sgl, default 345.77 ftz c. WA R= ftz SHGC: Tinted, default 11. Ducts b__U-Factor. N/A ftz a. Sup: Attic Ret: Attic AH: Attic Sup. R= 6, 201 ftz - SHGC: 12. Cooling systems c. U-Factor: N/A ftz a. Central Unit Cap: 57.0 kBtu/hr SHGC: SEER: 14.5 A. U-Factor. N/A ftz 13. Heating systems SHGC: e. U-Factor. N/A ftz a. Electric Heat Pump Cap: 57.0 kBtu/hr SHGC: HSPF:8.8 8. Floor Types Insulation Area 14. Hot water systems a. Slab -On -Grade Edge Insulation R=0.0 2618.00 ftz a. Electric Cap: 50 gallons ns ns b. N/A R= ftz EF: 0.9 c. WA R= ftz b. Conservation features None 15. Credits CF, Pstat Glass/Floor Area: 0.132 Total As -Built Modified Loads: 42.92 PASS Total Baseline Loads: 51.41 hereby certify that the plans and specifications covered by Review of the plans and Sr'4?� this calculation are in compliance with the Florida Energy specifications covered by this D�viE ti = O Code. calculation indicates compliance with the Florida Energy Code.�O PREPARED BY:4& Before construction is completed DATE: _ this building will be inspected for compliance with Section 553.908 ~I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energ Code. G'0 WET OWNER/AGENT: ( BUILDING OFFICIAL: GATE: _ DATE: n 3/24/2011 9:08 AM EnergyGauge® USA - FlaRes2008 Page 1 of 5 • r PROJECT Title: NOBLE RESIDENCE Bedrooms: 4 Adress Type: Street Address Building Type: FLAsBuilt Bathrooms: 0 Lot # Owner Conditioned Area: 2618 SubDivision: - # of Units: 1 Total Stories: 1 PlatBook: Builder Name: Worst Case: No Street: Permifaffice: Rotate Angle: 0 County: ST. LUCIE COUNTY Jurisdiction: Cross Ventilation: No City, State, Zip: FT. PIERCE, Family Type: Single-family Whole House Fan: No FL, New/Existing: New (From Plans) Comment: CLIMATE V IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL ST LUCIE_CO INTL 2 39 90 75 70 722 62 Low FLOORS # Floor Type Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio 279.4 ft 0 2618 ft2 0 0 1 ROOF V Roof Gable Roof Solar Deck # Type Materials Area Area Color Absor. Tested Insul. Pitch 1 Gable or Shed Composition shingles 2759 ft2 436 ft2 Medium 0.9 N 0 18.4 deg ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2618 ft2 N N CEILING # Ceiling Type R-Value Area Framing Frac Truss Type 1 Under Attic (Vented) 19 2618 ft2 0.1 Wood WALLS Cavity Sheathing Framing Solar # Ornt Adjacent To Wall Type R-Value Area R-Value Fraction Absor. 1 N Exterior Concrete Block - Ext Insul 5.4 140.03 ft2 0 0 0.8 2 NE Exterior Concrete Block - Ext Insul 5.4 393 ft2 0 0.8 3 E Exterior Concrete Block - Ext Insul 5.4 74.5 ft2 0 0.8 4 SE Exterior Concrete Block - Ext Insul 5.4 523.05 ft2 0 0 0.8 5 S Exterior Concrete Block - Ext Insul 5.4 23.6 ft2 0 0.8 6 SW Exterior Concrete Block - Ext Insul 5.4 528.4 ft2 0 0.8 " 7 W Exterior Concrete Block - Ext Insul 5.4 87.2 ft2 0 0.8 8 NW Exterior Concrete Block - Ext Insul 5.4 654.76 ft2 0 0.8 • DOORS # Ornt Door Type Storms U-Value Area 1 SE Insulated None 0.39 42 ft2 - WINDOWS Window orientation below is as entered. Actual orientation is modified by rotate angle shown in 'Project' section above. / Overhang v # Ornt Frame Panes NFRC U-Factor SHGC Storms Area Depth Separation Int Shade Screening 1 N None Single (Tinted) No 0.5 0.64 N 40.43 ft2 2 ft 0 in 7 ft 0 in HERS 2006 None 2 NE None Single (Tinted) No 0.5 0.64 N 30 ft2 2 ft 0 in 6 ft 0 in HERS 2006 None 3 E None Single (Tinted) No 0.5 0.64 N 14.58 ft2 2 ft 0 in 6 ft 0 in HERS 2006 None 4 SE None Single (Tinted) No 0.5 0.64 N 40 ftz 2 ft 0 in 6 ft 0 in HERS 2006 None 5 S None Single (Tinted) No 0.5 0.64 N 14.58 ft2 2 ft 0 in 6 ft 0 in HERS 2006 None 6 SW None Single (Tinted) No 0.5 0.64 N 45 ft2 2 ft 0 in 6 ft 0 in HERS 2006 None 7 SW None Single (Tinted) No 0.5 0.64 N 47.6 ft2 2 ft 0 in 7 ft 0 in HERS 2006 None 8 SW None Single (Tinted) No 0.5 0.64 N 6 ft2 2 ft 0 in 4 ft 0 in HERS 2006 None 9 SW None Single (Tinted) No 0.5 0.64 N 12 ft2 2 ft 0 in 5 ft 0 in HERS 2006 None 10 W None Single (Tinted) No 0.5 0.64 N 14.58 ft2 2 ft 0 in 6 ft 0 in HERS 2006 None 11 NW None Single (Tinted) No 0.5 0.64 N 75 ft2 2 ft 0 in 6 ft 0 in HERS 2006 None 12 NW None Single (Tinted) No 0.5 0.64 N 6 ft2 2 ft 0 in 4 ft 0 in HERS 2006 None INFILTRATION & VENTING - Forced Ventilation - Run Time Fan Method SLA CFM 50 ACH 50 ELA EgLA Supply CFM Exhaust CFM Fraction Wafts Default 0.00036 2472 7.08 135.7 255.2 0 cfm 0 cfm 0 0 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Ductless 1 Central Unit None SEER: 14.5 57 kBtu/hr cfm 0.7 FALSE HEATING SYSTEM # System Type Subtype Efficiency Capacity Ductless 1 Electric Heat Pump None HSPF: 8.8 57 kBtu/hr FALSE HOT WATER SYSTEM # System Type EF Cap Use SetPnt Conservation 1 Electric 0.9 50 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS — Supply — — Return — Air Percent V/ # Location R-Value Area Location Area Leakage Type Handler CFM 25 Leakage QN RLF 1 Attic 6 201 ftZ Attic 20 ftZ Default Leakage Attic TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan HeatiX1 Feb Jan Mar Rj Apr X Ma �X� Jun Jul Jul Jun Ri AugX Se Oct Nov rNov i Dec Dec Ri Venting Jan Feb Mar Apr May X� Jul lXj Auun g Sep Lx� Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 FORM 1100A-08 Code Compliance Cheklist Residential Whole Building Performance Method A - Details ADDRESS: PERMIT #: FT. PIERCE, FL, INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors N1106.AB.1.1 Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area. Exterior & Adjacent Walls N1106.AB.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from, and is sealed to, the foundation to the top plate. Floors N1106.AB.1.2.2 Penetrations/openings > 1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings N1106.AB.1.2.3 Between walls & ceilings; penetrations of ceiling plane to top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures N1106.AB.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC with < 2.0 cfm from conditioned space, tested. Multi -story Houses N 1 106.AB. 1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts N1106.AB.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters N1112.AB.3 Comply with efficiency requirements in Table N112.ABC.3. Switch or clearly marked circuit breaker (electric) or cutoff (gas) must be provided. External or built-in heat trap required. Swimming Pools & Spas N1112.AB.2.3 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. Heat pump pool heaters shall have a minimum COP of 4.0. Shower heads N1112.AB.2.4 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems N1110.AB All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated and installed in accordance with the criteria of Section N1110.AB. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls N1107.AB.2 Separate readily accessible manual or automatic thermostat for each system. Insulation N1104.AB.1 Ceilings -Min. R-19. Common walls -frame R-11 or CBS R-3 both N1102.13.1.1 sides. Common ceiling & floors R-11. ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD _ ESTIMATED ENERGY PERFORMANCE INDEX* = 83 The lower the EnergyPerformance Index, the more efficient the home. , FT. PIERCE, FL, 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows— Description a. U-Factor: Sgl, default SHGC: Tinted, default b. U-Factor: N/A SHGC: c. U-Factor: N/A SHGC: d. U-Factor. N/A SHGC: e. U-Factor: N/A SHGC: 8. Floor Types a. Slab -On -Grade Edge Insulation b. N/A c. N/A New (From Plans) 9. Wall Types Insulation Area Single-family a. Concrete Block - Ext Insul, Exterior R=5.4 2424.50 ft2 b. N/A R= ft2 1 c. N/A R= ft2 4 d. N/A R= ft2 No 10. Ceiling Types Insulation Area 2618 a. Under Attic (Vented) R=19.0 2618.00 ft2 b. N/A R= ft2 Area c. N/A R= ft2 345.77 ft2 11. Ducts ft2 a. Sup: Attic Ret: Attic AH: Attic Sup. R= 6, 201 ft2 12. Cooling systems ft2 a. Central Unit Cap: 57.0 kBtu/hr SEER: 14.5 ft2 13. Heating systems a. Electric Heat Pump Cap: 57.0 kBtu/hr HSPF: 8.8 14. Hot water systems Insulation Area a. Electric Cap: 50 allons R=0.0 2618.00 ft2 EF: 0.9 R= ft2 Ev b. Conservation feat esR= ft2 None15. Credits 0 P-F, Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise; a new EPL Display Card will be completed based on installed Code complian�feptures. 1�1 Address of New Home: City/FL Zip: *Note: The home's estimated Energy Performance Index is only available through the EnergyGauge USA - FlaRes2008 computer program. This is not a Building Energy Rating. If your Index is below 100, your home may qualify for incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at (321) 638-1492 or see the Energy Gauge web site at energygauge.com for information and a list of certified Raters. For information about Florida's Energy Efficiency Code for Building Construction, contact the A Department of Community Affairs at (850) 487-1824. **Label required by Section 13-104.4.5 of the Florida Building Code, Building, or Section B2.1.1 of Appendix G of the Florida Building Code, Residential, if not DEFAULT. EnergyGauge® USA - FlaRes2008 Project Summary Job: : Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@/\OL.COM For: NOBLE RESIDENCE ST. LUCIE COUNTY,F L Notes: Weather: Fort Pierce, FL, US Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 30571 Btuh Ducts 0 Btuh Central vent (76 cfm) 2332 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 32903 Btuh Infiltration Method Construction quality Fireplaces Area (ft2) Volume (ft3) Air changes/hour Equiv. AVF (cfm) Simplified Average 0 He tin Co li 2618 2618 23933 23933 0.32 0.16 128 64 Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range Reative Humidity L 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 43530 Btuh Ducts 0 Btuh Central vent (76 cfm) 1249 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 42540 Btuh Latent Cooling Equipment Load Sizing Structure 2866 Btuh Ducts 0 Btuh Central vent (76 cfm) 3166 Btuh Equipment latent load 6032 Btuh Equipment total load 48572 Btuh Req. total capacity at 0.70 SHR 5.1 ton Heating Equipment Summary Cooling Equipment Summary Make Amana Make Amana Trade ASZ14 SERIES Trade ASZ14 SERIES Model ASZ140601A* Cond ASZ140601A* ARI ref no. 1288567 Coil ASPF426016A*+TXV ARI ref no. 1288567 Efficiency 8.8 HSPF Efficiency 14.5 EER Heating Input Sensible cooling 39900 Btuh Heating output 59000 Btuh @ 47°F Latent cooling 17100 Btuh Temperature rise 28 OF Total cooling 57000 Btuh Actual air flow 1900 cfm Actual air flow 1900 cfm Air flow factor 0.062 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.88 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. ^'� -Ff&- wrightsoft- Right -Suite® Universal 7.1.08 RSU08101 2011-Mar-24 09:06:03 ACM C:\Documents and Settings\Nikki_2\My Documents\Wrightsoft HVACWOBLE RES..rup Calc = MJ8 Orient Page 1 ° G , Right-M Worksheet Job: Entire House Date: r QUICK CALCS, INC. By. 317$T. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name Entire House MASTER BEDROOM 2 Exposed wall 279.4 ft 34.4 ft 3 Ceiling height 9.1 ft d 9.0 ft heat/cool 4 Room dimensions 1.0 x 226.0 ft 5 Room area 2626.2 ft2 226.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V t-- G 13A-5ocs 0.125. n 3:50 2.22 76 36 126 80 76, 36 126 80 1A-clomd 1.270 n 35.56 34.77 40 0 1431 1399 40 0 1431 1399 W Y-G 13A-5ocs 0.125 ne 3.50 2.22 423 393 1376 874 0 0 0 0 1A-clom 1.270 ne 35.56 70.43 30 0 1067 2113 0 0 0 0 VN �-G 11 13A-50cs IA-clom 0.125 1.270 a a 3.50 35.56 2.22 91.12 '89 15 75 0 261 519 166 1329 0 0 0 0- 0 0 0 0 WI - 13A-5ocs 0.125 se 3.50 2.22 525 443 1551 986 0 0 0 0 1A-clom 1.270 se 35.56 70.95 40 0 1422 2838 0 0 0 0 [::G �--D 11DO 0.390 se 10.92 11.31 42 42 459 475 0 0 0 0 W �G 13A-5ocs 0.125 s 3.50 2.22 38 24 83 53 0 0 0 0 1A-clam 1.270 s 35.56 34.77 15 ° 15 519 507 0 0 0 0 13A-5ocs 0.125 sw 3.50 2.22 639 528 1849 1176 162 132 462 294 1A-clom 1.270 sw 35.56 70.95 45 0 1600 3193 30 0 1067 2128 IA-clomd 1.270 sw 35.56 70.95 48 0 1693 3377 0 0 0 0 1 D-c2om 0.870 sw 24.36 59.41 6 0 146 356 0 0 0 0 1 D-c2om 0.870 sw 24.36 59.41 12 0 292 713 0 0 0 0 �i �--G 13A-5ocs 0.125 . w 3.50 2.22 -102 87 305 194 0 0 0 0 1A-c1om 1.270 w 35.56 91.12 15 0 519 1329 0 0. 0 0 VjJ It--GG 13A-5ocs 0.125 nw 3.50 2.22 657 576 2016 1282 72 72 252 160 IA-clom 1.270 nw 35.56 70.43 75 0 2667 5282 0 0 0 0 1 D-c2om 0.870 nw 24.36 58.95 6 0 146 354 0 0 0 0 P 12G-0sw. 0.091 - ..2.55 1.28 396 396, 1009 508, 0 0 0 0 C 166-19ad 0.049 - 1.37 2.57 2626 2626 3603 6756 226 226 310 581 F 21A-20c 0,027 - 0,76 0.00 2626 2626 1985 0 226 226 171 0 6 c) AED excursion 2109 115 Envelope loss/gain 26643 37448 3819 4758 12 a) Infiltration 3928 1052 478 128 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances @ 1200 4 48001 0 0 Subtotal (lines 6 to 13) 30571 43530 4297 4886 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 -0 0 0 14 Subtotal 30571 43530 4297 4886 15 Duct loads 0% 0% 0 0 0% 0% 0 0 Total room load 30571 43530 4297 4886 Air required (cfm) 1900 1900 267 213 Printout certified by ACCA to meet all reauirements of Manual J 8th Ed. Cs -i e- wrigf�tsoft- Right -Suite® Universal 7.1.08 RSU08101 2011-Mar-24 09:06:04 iR.a...P. C:\Documents and Seftings\Nikki_21My Documents\Wrightsoft HVACWOBLE RES..rup Calc = MJ8 Orient Page 1 Right-JO Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name WIC WIC 2 2 Exposed wall 6.0 ft 0 ft 3 Ceiling height 9.0 ft heatf000l 9.0 ft heat(cool 4 Room dimensions 6.0 x 6.0 ft 1.0 x 31.5 ft 5 Room area 36.0 ft2 31.5 ft' Ty Construction U-value Or HTM Area (ftZ) Load Area (ftZ) Load number. (Btuh/ftz-°F) (13tuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V,U I---G 13A-5ocs 0.126, n 3.50 2.22 0 0 0 0 0 0 0 0 to-clomd 13A-5ocs 1.270 0.125 n ne 35.56 3.50 34.77 2.22 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 �j 11 IA-clom 13A-5ocs 1A-clom 1.270 0.125 1.270 ne a a 35.56 3.50 35.56 70.43 2.22 91.12 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -G W �--G �--G 13A-5ocs 0.125 se 3.50 2.22 0 0 0 0 0 0 0 0 1A=clom 11bo 1.270 0.390 se se 35.56 10.92 70.95 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 LLL--DDD Val �G 13A-5ocs IA-b1om 0.125 1.270 s s 3.50 35.56 2.22 34.77 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13A-5ocs 0.125 sw 3.50 2.22 54 54 189 120 0 0 0 0 1A-clom 1.270 sw 35.56 70.95 0 0 0 0 0 0 0 0 IA-clomd 1.270 sw 35.56 70.95 0 0 0 0 0 0 0 0 1 D-c2om 1 D-c2om 0.870 0.870 sw sw 24.36 24.36 59.41 59.41 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 VLW, G' 13A-5ocs 0.125 w 3.50 2.22 0 0; 0 a .0 0 0 0 1A-clom 1.270 w 35.56 91:12 0 0 0 0 0 0 0 0 13A-5ocs 0.125 nw 3.50 2.22 0 0 0 0 0 0 0 0 1A-clom 1 D-c2om 1.270 0.870 nw nw 35.56 24.36 70.43 58.95 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 P 12C-Osw 0.091' - 2.55 1.28 0 0 0 0 0 0 0 0 C 16B-19ad 0.049 - 1.37 2.57 36 36 49 93 32 32 43 81 F 21A-20c 0,027 0,76 0.00 30 36 27 0 32 32 24 0 6 c) AED excursion -20 -7 Envelope loss/gain 266 192 67 74 12 a) Infiltration 83 22 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 1200 0 0 01 1 0 Subtotal (lines 6 to 13) 349 215 67 74 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 349 215 67 74 15 Duct loads 0% 0% 0 0 0% 0% 0 0 Total room load 349 215 67 74 Air required (cfm) 22 9 4 3 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. -�- wrigtitsoTt- Right -Suite® Universal 7.1.08 RSU08101 2011-Mar-24 09:06:04 C:1Documents and SettingsWikki_2wy Documents\Wrightsoft HVACWOBLE RES..rup Cale= MJ8 Orient Page 2 Rig ht-JO Worksheet Entire House QUICK CALCS, INC. 317ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@,AOL.COM Job: Date: By: 1 Room name MASTER BATH STUDY 2 Exposed wall 16.9 ft 31.4 ft 3 Ceiling height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 1.0 x 158.0 ft 1.0 x 152.0 ft 5 Room area 158.0 ft2 152.0 ft2 Ty Construction U-value Or HTM Area (W) Load Area (W) Load number (Btuh/ft2-°F) (13tuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W, G 13k5ocs 0.125 n 150 2:22 b 0 0 0 0 0 0 0 1A-'clomd 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0 W Y--G 13A-5ocs 0.125 ne 3.50 2.22 0 0 0 0 63 63 221 140 1A-clom 1.270 ne 35.56 70.43 0 0 0 0 0 0 0 0 ' G 11 13A-5ocs 1A-clom 0.125' 1.270 a a 3.50 35.56 2.22 91.12. 0 0 0 0 0 0 0' 0 38 15 24 0 83 519 53 1329 �i 13A-5ocs 0.125 se 3.50 2.22 27 27 95 60 54 34 119 76 1A-clom 1.270 se 35.56 70.95 0 0 0 0 20 0 711 1419 �C �D W �-G 11 DO 13A-50cs IA-clom 0.390 0.125 1.270 se s s. 10.92 3.50 35.56 11.31 2.22 34.77 0 0 0 0 0 0 0 0 0 0 0 0 0 38 15 0 24 15 0 83 519 0 53 507 VN 13A-5ocs 0.125 sw 3.50 2.22 126 108 378 240 90 90 315 200 1A-clom 1.270 sw 35.56 70.95 0 0 0 0 0 0 0 0 1A-clomd 1.270 sw 35.56 70.95 0 0 0 0 0 0 0 0 1 D-c2om 1 D-c2om 0.870 0.870 sw sw 24.36 24.36 59.41 59.41 6 12 0 0 146 292 356 713 0 0 0 0 0 0 0 0 W, L--G 13A-5ocs - 0.125 w 3.50 2.22 0 0 0 0 0 0 0 0 IA-clom 1.270. .w 35.56 91.12 0 0 0 0 0. 0, 0 0 13A-5ocs 0.125 nw 3.50 2.22 0 0 0 0 0 0 0 0 1A-c1om 1.270 nw 35.56 70.43 0 0 0 0 0 0 0 0 1 D-c2om 0.870 nw 24.36 58.95 0 0 0 0 0 0 0 0 P 12C-Osw 0.091 2.55 1.28 0 0 0- 0 0 0 0 0 C 16B-19ad 0.049 - 1.37 2.57 158 158 217 406 152 152 209 391 F 21A-20c 0.027 0.76 0.00 158 .158 119. 0 152 152 115 0 6 c) AED excursion 253 37 Envelope loss/gain 1247 2029 2892 4204 12 a) Infiltration 236 63 437 117 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 1200 0 0 0 0 Subtotal (lines 6 to 13) 1483 2092 3328 4321 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1483 2092 3328 4321 15 Duct loads 0% 0% 0 0 0% 0% 0 0 Total room load 1483 2092 3328 4321 Air required (cfm) 92 91 207 189 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. . P. wriy�.tsoR- Right -Suite® universal 7.1.08 RSU08101 2011-Mar-24 09:06:04 C:\Documents and SeftingsWikki_2wy Documents\Wrightsoft HVACWOBLE RES..rup Calc = MJ8 Orient Page 3 p1 tc�x Right-.1® Worksheet Job: - Entire House Date: QUICK CALCS, INC. By. 317-ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@SOL.COM 1 Room name FOYER LIVING 2 Exposed wall 10.0 ft 9.0 ft 3 Ceiling height 12.0 ft heat/cool 9.0 It heat1cool 4- Room dimensions 1.0 x 99.0 ft 1.0 x 479.0 ft 5 Room area 99.0 ftz 479.0 ft2 Ty Construction U-value Or HTM Area (ftz) Load Area (ft2) Load number (Btuh/ft;°F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 T 13A-5ocs 0.125 n 3.50 2.22 0 0 0 .0 0 0 0 0 1A-clomd 1.270 n 135.56 34.77 0 0 0 0 0 0 0 0 -G 13A-5ocs 0.125 ne 3.50 2.22 0 0 0 0 0 0 0 0 IA-clom 1.270 ne 35.56 70.43 0 0 0 0 0 0 0 0 W �G 11 13A-5ocs 1A-clom 0.125 1.270 a a 3.50 35.56 2.22 91.12 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 �j 13A-5ocs 0.125 se 3.50 2.22 120 78 273 174 0 0 0 0 IA-clom 1.270 se 35.56 70.95 0 0 0 0 0 0 0 0 �G �D 11 DO 0.390 se 10.92 11.31 42 42 459 475 0 0 0 0 UN 13A-5ocs 1A-clam 0.125 1.270 s s 3.50 35.56 2.22 34.77 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 vu 13A-5ocs 0.125 sw 3.50 2.22 0 0 0 0 0 0 0 0 1A-clom 1.270 sw 35.56 70.95 0 0 0 0 0 0 0 0 IA-clomd 1.270 sw 35.56 70.95 0 0 0 0 0 0 0 0 1 D-c2om 1 D-c2om 0.870 0.870 sw sw 24.36 24.36 59.41 59.41 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13A-5ocs 0.125: w.: 3.50 2.22 0 ON 0 0 0 0 0 0 IA-clom 1.2M w 35.56 91.12 0 0 0 0 0 0 0 0 W,� �GG 13A-5ocs 0.125 nw 3.50 2.22 0 0 0 0 81 51 179 113 1A-clom 1 D-c2om 1.270 0.870 nw nw 35.56 24.36 70.43 58.95 0 0 0 0 0 0 0 0 30 0 0 0 1067 0 2113 0 P 12C-Osw 0.091` - 2.55 1.28 . 0 0 0 0 0 0 0, 0 C 16B-19ad 0.049 1.37 2.57 99 99 136 255 479 479 657 1232 F 21A-20c 0.027 - 0,76 0.00 99 99 75 0 479 479 362 0 6 c) AED excursion -83 159 Envelope loss/gain 942 821 2265 3617 12 a) Infiltration 185 50 125 33 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 1200 0 0 2 1 2400 Subtotal (lines 6 to 13) 11127 870 2389 6051 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 131 83 14 Subtotal 1127 870 2521 6134 15 Duct loads 1 0% 0% 0 0 0% 0% 0 0 Total room load 1127 870 2521 6134 Air required (cfm) 70 38 157 268 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. -Pf *- Right -Suite® Universal 7.1.08 RSU08101 2011-Mar-24 09:06:04 C:1Documents and SettingsWikki_2\My DocumentslWrightsoft HVACWOBLE RES..rup Calc = MJB Orient Page 4 Right-.1® Worksheet Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@,AOL.COM Job: Date: By: 1 Room name BATH 2 BEDROOM 2 2 Exposed wall 0 ft 21.0 ft 3 Ceiling height 9.0 ft heat1cool 9.0 ft heat/cool Room dimensions 10.0 x 5.0 ft 13.0 x 12.0 ft 5 Room area 50.0 ft2 156.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-OF) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W, -G 13A-5ocs 0.126 n 3.50 2.22 0 0 0 0 0 0 0 0 1A-clomd 1.270, n 35.56 34.77 0 0 0 0 0 0 D 0 13A-5ocs 0.125 ne 3.50 2.22 0 0 0 0 0 0 0 0 IA-clom 1.270 ne 35.56 70.43 0 0 0 0 0 0 0 0 11 13A-5ocs IA-clom 0.125 1.270 a a 3.50 35.56 2.22 91.12 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 �j 13A-5ocs 0.125 se 3.50 2.22 0 0 0 0 117 97 340 216 1A-clom 1.270 se 35.56 70.95 0 0 0 0 20 0 711 1419 �G �D 11 DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 13A-5ocs 0.125 s 3.50 2.22 0 0 0 0 0 0 0 0 IA-clom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 13A-5ocs 0.125 sw 3.50 2.22 0 0 0 0 72 72 252 160 1A-clom 1.270 sw 35.56 70.95 0 0 0 0 0 0 0 0 IA-clomd 1.270 sw 35.56 70.95 0 0 0 0 0 0 0 0 1 D-c2om 1 D-c2om 0.870 0.870 sw sw 24.36 24.36 59.41 59.41 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 WI - 13A-5ocs 0.125 w 3.50 2.22 0 0 0 0 0: 0 0 0 1A-clom 1.270 w 35.56 91.12 0 0 0 01 0 0 0 0 -i 13A-5ocs 0.125 nw 3.50 2.22 0 0 0 0 0 0 0 0 IA-clom 1.270 nw 35.56 70.43 0 0 0 0 0 0 0 0 1 D-c2om 0.870 nw 24.36 58.95 0 0 0 0 0 0 0 0 P 12C-0sw 0.091, - 2.55 1.28 0 0 0 0 108 108 275 139 C 16B-19ad 0.049 - 1.37 2.57 50 50 69 129 156 156 214 401 F 21A-20c 0,027 - 0,76 0,00 50 50 38 0 150 156 118 0 6 c) AED excursion -11 341 Envelope losstgain 106 117 1910 2676 12 a) Infiltration 0 0 291 78 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 l) Appliances @ 1200 0 1 01 0 1/0 Subtotal (lines 6 to 13) 106 117 2201 2754 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 82 52 49 31 14 Subtotal 189 169 2250 2785 15 Duct loads 0% 0% 0 0 0% 0% 0 0 Total room load 189 169 2250 2785 Air required (cfm) 12 7 140 122 Printout certified by ACCA to meet all reauirements of Manual J 8th Ed. --Vsj"Iz--vt- Right -Suite® Universal 7.1.08 RSU08101 2011-Mar-24 09:06:04 C:1Documents and SettingsWikki_2WIy DocumentslWrightsoft HVACWOBLE RES..rup Calc = MJ8 Orient Page 5 cs, Right-J® Worksheet Job: • Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@J\OL.COM 1 Room name HALL KITCHEN 2 Exposed wall O ft O ft 3 Ceiling height 9.0 ft heat/cool 9.0 ft heaUcool 4 Room dimensions 3.0 x 13.0 ft 1.0 x 169.5 ft 5 Room area 39.0 ft' 169.5 ft' Ty Construction number U-value (Btuh/ft2-°F) Or HTM t Area (ft2) I or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 13A-5ocs 0.126 n 3.50 2.22 0 0 0 0 0 0 0 0 �C IA-clomd 1.270. n 35.56 34.77 0 0, 0 0 0 0 0 0 W T-G 13A-5ocs 0.125 ne 3.50 2.22 0 0 0 0 0 0 0 0 1A-clom 1.270 ne 35.56 70.43 0 0 0 0 0 0 0 0 Val �G 11 13A-5ocs 1A-clom 0.125 1.270 a a 3:50 35.56 2.22 91.12 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 �i 13A-5ocs 1A-clam 0.125 1.270 se se 3.50 35.56 2.22 70.95 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I-G L -D W (-G 11130 13A-5ocs 1A-clom 0.390 0.125 1.270 se s s 10.92 3:50 35.56 11.31 2.22 34.77 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13A-5ocs 0.125 sw 3.50 2.22 0 0 0 0 0 0 0 0 1A-clom IA-clomd 1 D-c2om 1 D-c2om 1.270 1.270 0.870 0.870 sw sw sw sw 35.56 35.56 24.36 24.36 70.95 70.95 59.41 59.41 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 WJ t-G 13A-5ocs 1A-clom 0.125 1.270: w w 3.50 35.56 2.22 9.1.12 0 0 01 0 0 0' 0 0 0 0. 0 0 0 0 0 0 13A-5ocs 0.125 nw 3.50 2.22 0 0 0 0 0 0 0 0 IA-clom 1 D-c2om 1.270 0.870 nw nw 35.56 24.36 70.43 58.95 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 �G P 12C-Osw 0.091 - 2.55 1.28 90 90 229 115 0. A 0 0 C 16B-19ad 0.049 - 1.37 2.57 39 39 54 100 170 170 233 436 F 21A-20c 0,027, 0.76 0,00 39 39 29 0 170 170 128 0 6 c) AED excursion -19 -266 Envelope loss/gain 312 197 361 170 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances @ 1200 0 0 2 1 2400 Subtotal (lines 6 to 13) 312 197 361 2800 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -312 -197 170 104 14 Subtotal 0 0 531 2904 15 Duct loads 1 0% 0% 0 0 0% 0% 0 0 Total room load 0 0 531 2904 Air required (cfm) 0 0 33 127 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. '4ft-FP- Right -Suite® Universal 7.1.08 RSU08101 2011-Mar-24 09:06:04 C:\Documents and Settings\Nikki_2\My Documents\Wrightsoft HVACWOBLE RES..rup Calc = MJ8 Orient Page 6 • Right-J® Worksheet Job: • Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BREAKFAST FAMILY ROOM 2 Exposed wall 22.6 ft 24.7 ft 3 Ceiling height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 1.0 x 212.0 ft 1.0 x 268.0 ft 5 Room area 212.0 ft' 268.0 ft' Ty Construction U-value Or HTM Area (W) Load Area (ftz) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 �-G 13A-5ocs 0.125 ri 3.50 2.22 0 0 0 0 0 0 0 0 IA-clomd 1.270 . n. 35.56 , 34.77 0 0 0 0 0 0 0 0 W T-G 13A-5ocs 0.125 ne 3.50 2.22 0 0 0 0 19 19 66 42 1A-clom 1.270 ne 35.56 70.43 0 0 0 0 0 0 0 0 VE13A-5ocs `G 11 1A-clom 0.125 1.270. a a 3.50 35.56 2.22 91.12 0 0 0 0 0 0. 0 0 51 0 51 0 178 0 113 0 13A-5ccs 0.125 se 3.50 2.22 0 0 0 0 0 0 0 0 1A-clom 1.270 se 35.56 70.95 0 0 0 0 0 0 0 0 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 W ' 13A-5ocs 0.125 1.270 s s 3.50 35.56 2.22 34.77 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 G'IA-clom 13A-5ocs 0.125 sw 3.50 2.22 36 21 74 47 63 15 54 34 1A-clom 1.270 sw 35.56 70.95 15 0 533 1064 0 0 0 0 1A-clomd 1.270 sw 35.56 70.95 0 0 0 0 48 0 1693 3377 1 D-c2om 1 D-c2om 0.870 0.870 sw sw 24.36 24.36 59.41 59.41 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 yJ T-G 13A-5ocs: 0;125 w &50 2.22 51 36. 127 81 0 0 0 0 1A-clom 1.270 w 35.56 91.12 15 0 519 1329 0 0 0 0 W, 13A-5ocs 0.125 nw 3.50 2.22 117 102 357 227 90 60 210 133 1A-clom 1 D-c2om 1.270 0.870 nw nw 35.56 24.36 70.43 58.95 15 0 0 0 533 0 1056 0 30 0 0 0 1067 0 2113 0 r� P 12C-Osw 0.091 2.55 1.28 0 0 0 0 0' .0 0 0 C 166-19ad 0.049 - 1.37 2.57 212 212 291 545 268 268 368 689 F 21A-20c 0.027 - 0.76 0.00 212 212 160 0 268 268 203 0 6 c) AED excursion 864 1174 Envelope loss/gain 2594 5213 3837 7676 12 a) Infiltration 314 84 343 92 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 1200 0 1 01 0 1 0 Subtotal (lines 6 to 13) 2908 5297 4181 7768 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2908 5297 4181 7768 15 Duct loads 1 0% 0% 0 0 0% 0% 0 0 Total room load 2908 5297 4181 7768 Air required (cfm) 181 231 260 339 Printout certified by ACCA to meet all reouirements of Manual J 8th Ed. -�$+- wrigr+tsoft- Right -Suite® universal 7.1.08 RSU08101 2011-Mar-24 09:06:04 C:\Documents and SettingsWikki_2WIy Documents\Wrightsoft HVACWOBLE RES..rup Calc = MJ8 Orient Page 7 VU M -s. Right-J® Worksheet Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@/10L.COM Job: Date: By: 1 2 Room name Exposed wall HALLWAY O ft LAUNDRY O ft 3 4 5 Ceiling height Room dimensions Room area 9.0 ft heat/cool 14.0 x 3.0 ft 42.0 ft2 9.0 ft heat/cool 9.0 x 6.0 ft 54.0 ft2 Ty Construction U-value Or HTM Area 2 (ft2) Load number (Btuh/ft�-°F) (Btuh/ft2) or perimeter (ft) (Btuh) ore perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6VE-G13A-5ocs IA-clomd 13A-5ocs 0.126 1.270.. 0.125 n n. ne 3.60 35.56 3.50 '2.22 34.77 2.22 0 0 0 0 0 0 0 0 0 0' 0 0 0• 0 0 0 0 0 0 0 0 0 0 0 11 1A-clom 13A-5ocs IA-c1om 13A-5ocs IA-clom 11 DO 13A-5ocs 1A-c1om 13A-5ocs 1.270 0.125 1.270 0.125 1.270 0.390 0.125 1.270 0.125 ne e" a se se se s s sw 35.56 3.50 35.56 3.50 35.56 10.92 3.50 35,56 3.50 70.43 2.22 91.12 2.22 70.95 11.31 2.22 34.77 2.22 0 0 0 0 0 0 0 0 0 0 0 0; 0 0 0 0 0 0 0 0 0 0 0 0 0 - 0 0 0 0 0 0 0 0 0 01 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 T-G �i �G -D VN L--G 1A-clom 1.270 sw 35.56 70.95 0 0 0 0 0 0 0 0 1A-clomd 1 D-c2om 1 D-c2om 13A-5ocs IA-clom 13A-5ocs IA-clom 1 D-c2om 12C-Osw 1613-19ad 21A-20c 1.270 0.870 0.870 0.125 1.270 0.125 1.270 0.870 0.091 0.049 0.027 sw sw sw w w nw nw nw - - - 35.56 24.36 24.36 3.50 35.56 3,50 35.56 24.36 2.55 1.37 0.76 70.95 59.41 59.41 2.22 91.12' 2.22 70.43 58.95 1.28 2.57 0.00 0 0 0 ,- 0 0 0 0 0 126 42 42' 0 0 0 0 0 0 0 0 126 42 42 0 0 0 0 0 0 0 0 321 58 32 0 0 0 0 0 0 0 0 .162 108 0 0 0 0 0 0 0 0 0 0 54 54' 0 0 0 0 0 0 0 0 0 54 54 0 0 0 0 0 0 0 0 0 74 41.' 0 0 0 0 0 0 0 0 0 139 0 �i I-G VG P C F 6 c) AED excursion -23 -12 Envelope loss/gain 410 246 115 127 12 a) Infiltration b) Room ventilation 0 0 0 0 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 1200 0 0 0 0 Subtotal (lines 6 to 13) 410 246 115 127 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 0% 0% 0 0 410 0 0 0 0 -246 0 0 0% 0% 0 0 217 332 0 0 0 130 257 0 Total room load Air required (cfm) 0 0 0 0 332 21 257 11 Printout certified by ACCA to meet all reouirements of Manual J 8th Ed Ate- -�- wrigi�tsoft- Right -Suite® Universal 7.1.08 RSU08101 2011-Mar-24 09:06:04 C:\Documents and SettingMikki_My Documents\Wrightsoft HVAC\NOBLE RES..rup Calc = MJB Orient Page 8 Right-JO Worksheet Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM Job: Date: By: 1 Room name CLOSET 2 CLOSET 2 Exposed wall 1.0 ft 2.0 ft 3 Ceiling height 9.0 ft heat/cool 9.0 ft heat1cool 4 Room dimensions 8.0 x 5.0 ft 1.0 x 39.5 ft 5 Room area 40.0 ftz 39.5 ft' Ty Construction U-value Or HTM Area '(ft� Load Area (W) Load number (13tuh/fl:22F) (Bt or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/PIS Heat Cool Gross N/PIS Heat Cool 6 W, 13A-5ocs 0.125 n 3.50 2.22 0 0 0 0 0 0 0 0 1A-clomd 1.270 n 35.56 34.77 0 0 0 0 0 10 0 0 13A-5ocs 0.125 ne 3.50 2.22 9 9 32 20 9 9 32 20 1A-clom 1.270 ne 35.56 70.43 0 0 0 0 0 0 0 0 ILG 11 13A-5ocs 1A-clom 0.125 1.270 a a 3.50 35.56 2.22 91.12 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 �i 13A-5ocs 0.125 se 3.50 2.22 0 0 0 0 9 9 32 20 IA-clom 1.270 se 35.56 70.95 0 0 0 0 0 0 0 0 �G �--D 11 DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 V�1 ' G 13A-5ocs 1A-clom 0.125. 1.270, s s 3.50 35.56 2.22 34.77 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13A-5ocs 0.125 sw 3.50 2.22 0 0 0 0 0 0 0 0 IA-clom 1.270 sw 35.56 70.95 0 0 0 0 0 0 0 0 1A-clomd 1.270 sw 35.56 70.95 0 0 0 0 0 0 0 0 1 D-c2om 1 D-c2om 0.870 0.870 sw sw 24.36 24.36 59.41 59.41 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13A-5ocs 0.125 w 3.50 2.22 0 0 0 0 0 0 0 0 1A;clom 1.270 w 35.56 91.12 0' 0 0 0 0 0 0 0 13A-5ocs 0.125 nw 3.50 2.22 0 0 0 0 0 0 0 0 1A-clom 1.270 nw 35.56 70.43 0 0 0 0 0 0 0 0 1 D-c2om 0.870 nw 24.36 58.95 0 0 0 0 0 0 0 0 P 12C-Osw 0.091 -. 2.55 1.28 0' 0 0 0 0 0 0 0 C 16B-19ad 0.049 - 1.37 2.57 40 40 55 103 40 40 54 102 F 21A-20c 0,027 - 0.76 0.00 40 40 30 0 40 40 30 0 6 c) AED excursion -11 -13 Envelope loss/gain 117 112 147 129 12 a) Infiltration 14 4 28 7 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 1200 0 0 0 0 Subtotal (lines 6 to 13) 1130 116 175 136 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 130 116 175 136 1151 Duct loads 1 0% 0% 0 0 0% 0% 0 0 Total room load 130 116 175 136 Air required (cfm) 8 5 11 6 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. -�- wrigF.tsoft- Right -Suite® Universal 7.1.08 RSU08101 2011-Mar-24 09:06:04 C:XDocuments and SettingsWikki_21My Documents%Wrightsoft HVACWOBLE RES..rup Calc = MJ8 Orient Page 9 Right-M Worksheet Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM Job: Date: By: 1 Room name BATH 3 BEDROOM 4 2 Exposed wall 33.0 ft 38.4 ft 3 Ceiling height 9.0 ft heat1cool 9.0 ft heat/cool 4 Room dimensions 1.0 x 78.5 ft 1.0 x 140.2 ft 5 Room area 78.5 ftz 140.2 ftz Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load number (Btuh/W-OF) (Btuh/ft-) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 VL 13A-5ocs 0.125. n 3.50 2.22 0 0 0 0 0 0 0 0 1A-clomd 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0 W, 13A-5ocs 0.125 ne 3.50 2.22 90 90 315 200 116 101 354 225 1A-clom 1.270 ne 35.56 70.43 0 0 0 0 15 0 533 1056 -G W �G 11 13A-5ocs IA-clom 0.125 1.270 a a 3.50 35.56 2.22 91.12 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 L913A-5ocs 0.125 se 3.50 2.22 63 63 221 140 99 99 347 220 1A-clom 1.270 se 35.56 70.95 0 0 0 0 0 0 0 0 11 DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 W T-G 13A-5ocs 0.125 s 3.50 2.22 0 0 0 0 0 0 0 0 1A-clom, 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 W 13A-5ocs 0.125 sw 3.50 2.22 19 19 66 42 17 17 60 38 IA-clom 1.270 sw 35.56 70.95 0 0 0 0 0 0 0 0 1A-clomd 1.270 sw 35.56 70.95 0 0 0 0 0 0 0 0 1 D-c2om 0.870 sw 24.36 59.41 0 0 0 0 0 0 0 0 1 D-c2om 0.870 sw 24.36 59.41 0 0 0 0 0 0 0 0 W L--G 13A-5ocs 0.125 w 3.50 2.22 0 0 0 0 51 51 178 113 IA-clom 1.270 w 35.56 91.12 0 0 0 0 0 0 0 0 13A-5ocs 0.125 nw 3.50 2.22 126 120 420 267 63 63 221 140 1A-clom 1.270 nw 35.56 70.43 0 0 0 0 0 0 0 0 1D-c2om 0.870 nw 24.36 58.95 6 0 146 354 0 0 0 0 P 12C-Osw 0.091: - 2.55' 1.28 0 0 0 0 0 .0 0 0 C 16B-19ad 0.049 1.37 2.57 79 79 108 202 140 140 192 361 F 21A-20c 0,027: - 0.76 0.00 79 79 59 0 140 140 106 0 6 c) AED excursion 8 -193 Envelope losstgain 1334 1213 1992 1962 12 a) Infiltration 459 123 534 143 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 1200 0 1 0 0 0 Subtotal (lines 6 to 13) 1793 1336 2525 2105 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1793 1336 2525 2105 15 Duct loads 10% 0% 0 0 0% 0% 0 0 Total room load 1793 1336 2525 2105 Air required (cfm) 111 58 157 92 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. Right -Suite® Universal 7.1.08 RSU08101 2011-Mar-24 09:06:04 C:\Documents and SettingsWikki_21My Documents\Wrightsoft HVACWOBLE RES..rup Calc= MJ8 Orient Page 10 Right-M Worksheet Job: Entire House Date: By. QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BEDROOM 3 2 Exposed wall 29.0 ft 3 Ceiling height 9.0 ft heat/cool 4 Room dimensions 12.0 x 13.0 ft 5 Room area 156.0 ftz Ty Construction U-value Or HTM Area (ftq Load Area Load number (Btuh/ft? `F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V,V L-C 13A-5ocs .0.125 n 3.50 2.22 0 0 0 0 1A-clomd 1.270 n 35.56 34.77 0 0 0 0 VV T-G 13A-5ocs 0.125 ne 3.50 2.22 117 102 357 227 1A-clom 1.270 ne 35.56 70.43 15 0 533 1056 �-G 11 13A-5ocs 1A-clom 0.125 1.270 ,e a 3.50 35.56 2.22 91.12 0 0 0 0 0 0 0 0 �i 13A-5ocs 0.125 se 3.50 2.22 36 36 126 80 1A-clom 1.270 se 35.56 70.95 0 0 0 0 �G �-D 11D0 0.390 se 10.92 11.31 0 0 0 0 W L-G 13A-5ocs IA-clom 0.125 1.270 s s 3.50 35.56 2.22 34.77 0 0 0 0 0 0 0 0 VN 13A-5ocs 0.125 sw 3.50 2.22 0 0 0 0 1A-clom 1.270 sw 35.56 70.95 0 0 0 0 1A-clomd 1.270 sw 35.56 70.95 0 0 0 0 1 D-c2om 0.870 sw 24.36 59.41 0 0 0 0 1 D-c2om 0.870 sw 24.36 59.41 0 0 0 0 13A-5ocs 0.125 w 3.50 2.22 0 10, 0 0 1A-clom 1.270. w 35.56 -.91.12 0- 0 0 0 13A-5ocs 0.125 nw 3.50 2.22 108 108 378 240 1A-clom 1 D-c2om 1.270 0.870 nw nw 35.56 24.36 70.43 58.95 0 0 0 0 0 0 0 0 P 12C-Osw. 0.091 . - 2.55 1.28 72 72 183 92 C 16B-19ad 0.049 1.37 2.57 156 156 214 401 F 21A-20c - 0.027 - 0.76 0,00 156 156 118 0 6 c) AED excursion -185 Envelope loss/gain 1910 1913 12 a) Infiltration 402 108 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances @ 1200 0 0 Subtotal (lines 6 to 13) 1 2312 2021 Less external load 0 0 Less transfer 0 0 Redistribution 72 43 14 Subtotal 2384 2064 15 Duct loads 0% 0% 0 0 Total room load 2384 2064 Air required (cfm) 148 90 Printout certified by ACCA to meet all reauirements of Manual J 8th Ed. +$�- wrigr�tsoTt- Right -Suite® Universal 7.1.08 RSU08101 2011-Mar-24 09:06:04 C:1Documents and SettingsWikki_2WIy DocumentslWrightsoft HVACWOBLE RES..rup Calc= MJ8 Orient Page 11