HomeMy WebLinkAboutflashing detail,M
SET BOLTS IN
ELASTOMERIC
Bq
SEALANT
MI
OTT N Tp
ENUIOF
NEOPRENE PAD
NEp
FASTENERS APPROX.
12' O.C.
REMOIABLE
COUNTERFLASHING
INSULATION AS
FASTENERS APPROX.
SPECIFIED
9' O.C.
DERBIGUM
FLASHING MEMBRANE
DECK AS SPECIFIED
015ORGANIC
FELT BACKER SHEET
PERLITE CANT STRIP
(OPTIONAL)
SET IN BITUMEN
DERBIGUM MEMBRANE
SYSTEM BASE PU(S)
NOTE:
THIS DETAILALLOWS FOR ROOF MAIWAINENCE AROUND EQUIPMENT. THE CONTINUOUS SUPPORT
IS
PREFERRED IN LIGHTWEIGHT ROOF SYSTEMS BECAUSE THE EQUIPMENT WEIGHTCAN BE SPREAD
OVER
MORE SUPPORTING MEMBERS. CLEARANCE MUST BE PROVIDED FOR REMOIAL OF ROOFING AND
FLASHING BETWEEN PARALLEL SUPPORTS.
P-11 FLASHED CURB MOUNT DETAIL
Effective Date July 1. 2004
•
0
METAL RECEIVER -
FASTENERS APPROX.
3' LAP WITH
24'OC
SEALANT
LAP METAL AT JOINTS
f "S' W LAPS
FLEXIBLE VAPOR
OPTIONAL )
RETARDER FOR
INSULATION RETAINER
REMO ABLE
COUNTERFLASHING
2 WIDE CLIPAPPROX.
COMPRESSIBLE
24'OC
INSULATION ,
DERBIGUM
FLASHING MEMBRANE
WOOD CANT STRIP '
FASTENERSAPPROX.
8"0C
WOOD NAILER
SECURED TO DECK
WITH APPROPRIATE
A15 ORGANIC
FASTENERS 24'OC
FELT SEALER SHEET
(OPTIONAL)
DERBIGUM MEMBRANE
SYSTEM BASE PLY(s)
THIS DETAIL ALLOWS WALL AND DECK TO MOVE INDEPENDENTLY. IT SHOULD BE USED
WHERE THERE IS ANY POSSIBILITY
THAT DIFFERENTIAL MOVEMENT WILL OCCUR BETWEEN THE DECK AND VERTICAL SURFACE, SUCH AS A PENTHOUSE WALL.
THE VERTICAL WOOD MEMBER SHOULD BE FASTENED TO THE DECK ONLY. THIS IS ONE
METHOD OF JOINING THE TWO PEICE
FLASHING SYSTEM, OTHER METHODS MAY BE USED.
P-1 WALL ISOLATION DETAIL
Effective Date July 1, 2004
rawauMa
0
STRUCTURALFRAME
DERBIGUM
FLASHING MEMBRANE
CAULK WITH
NAIL FLANGE TO
ELASTOMERIC
WOOD NAILER - SET
SEALANT
FLANGE IN ROOFING
CEMENT OVER ROOF
DRAW BAND
MEMBRANE - PRIME
FLANGE BEFORE
STRIPPING
WPERTIGHT
UMBRELLA
WELDED ANCHOR
PLWE
DERBIGUM
MEMBRANE
SYSTEM BASE PLY(s)
P-16 FRAME - TYPE EQUIPMENT MOUNT
J
16 GAUGE MIN, FRAME
20 GAUGE FRAMES FOR
FOR HEM UNITS
LIGHT UNITS
NOMINAL 12' WOOD
COUNTERFLASHING
FASTENED APPROX. 8"
NAILER
O.C.
DERBIGUM
FLASHING MEMBRANE
INSULATION AS
SPECIFIED
FASTENERS APPROX, 8'
O.C.
AITERNWE FRAME
LOC9ION FOR HEAtY
UNITS
115 ORGANIC
FELT BACKER SHEET
PERLITE CANT STRIP
(OPTIONAL)
SET IN BITUMEN
DERBIGUM MEMBRANE
WOOD BLOCKING
FASTENED TO DECK
SYSTEM BASE PU(s)
P-10 PENETRATION CURB
Effecuve Uatu July 1, 2004
v v
/960A171N(E
0
FLEXIBLE\APOR
REARDER TO SERVE
DRIVE CLEAF OR
AS INSUUPION
SANDING SEAM JOINT
RETAINER IUTACHED
TO TOP OF CURB
WRERPROOFING
MEMBRANE OPTIONAL
CHAMFER TOP OF
WOOD CURBS TO
DRAIN TO ONE SIDE
FASTENERS APPROX. B
O.C. BOTH SIDES
COMPRESSIBLE
INSULKION
DERBIGUM
FLASHING
•
MEMEBRANE
i
WOOD NAILER EACH
SIDE SECURED TO
DECK WITH
FASTENERS
APPROPRIWE
APPROX.12' O.0
FASTENERS APPROX.
24' O.C.
DERBIGUM MEMBRANE
1' X 4' TREIUED WOOD
115 ORGANIC
CANT TO PROVIDE
FELT BACKER SHEET
STRUCTURAL
(OPTIONAL)
STRENGTH-NAILTOP
AND BOTTOM APPROX.
16' D.C.
SYSTEM BASE PLY(s)
NOTE:
THIS DETAILALLOWS FOR BUILDING MOVEMENT IN BOTH DIRECTIONS.
IT HAS PROVEN SUCCESSFUL
WITH MANY CONTRACTORS FOR MANY YEARS.
P-8 CURB EXPANSION JOINT DETAIL
,n
44,
�eranuMa
SMOOTH CONCRETE
CAULK WITH
EXPOSED SURFACES
ELASTOMERIC
MUST BE
SEALANT
WUERPROOFED
HEMMED EDGE
COMPRESSIBLE
ELASTOMERIC
ANGLE CLAMPING BAR
SEALANT1APE
WITH SLOTTED
ANCHOR HOLES
SEAL TOP OF
'r
FASTENERS 17 O.C.
FLASHING MEMBRANE
WITH GLASS FIBER
FASTENERS APPROX. 8'
FABRIC AND MASTIC
O.C.
DERBIGUM FLASHING
MEMBRANE
ATTACH WOOD
NAILER TO CONCRETE
WITH APPROPRIATE
N15 ORGANIC
FASTENER
FELT BACKER SHEET
(OPTIONAL)
PERLITE CANT STRIP
DERBIGUM MEMBRANE
SET IN BITUMEN
SYSTEM BASE PLY(s)
NOTE:
WHERE DECK IS SUPPORTED BY AND FASTENED TO THE CONCRETE DECK WALL,
VERTICAL WOOD NAILER SHOULD BE
SECURED TO THE WALL WITH SUITABLE FASTENERS.
P-3 WALUSURFACE MOUNTED COUNTERFLASHING
Fffechve Date July 1, 2004
A
0
10' MAXIMUM
DRIVE CLEW JOINT
LENGTH
EACH PIECE
SEAL TOP OF
FLASHING WITH
NWERPROOFING '
FABRIC AND MASTIC
MEMBRANE
FASTENERS APPROX.
8' O.C.
EXTERIOR GRADE
"1
114 X 1-1/2' SCREW
PLYWOOD ON CLEW -" :-%
FASTENERS APPROX.
OR TAPERED
24' O.C. THRU
BLOCKING TO
ELONGWED HOLES
PROVIDE SLOPE
115 ORGANIC
FELT BACKER SHEET
CONTINUOUS
(OPTIONAL)
CLEW
ASPHALT PRIMER
PERLITE CANT STRIP
DERBIGUM
SET IN BITUMEN
BASE FLASHING
DERBIGUM MEMBRANE
SYSTEM BASE PLY(s)
NOTE:
THIS DEWIL SHOULD BE USED ONLY WHEN THE DECK IS SUPPORTED BYTHE WALL
P-2 WALL FLASHING DETAIL
Effective Date July 1. 2004
0
DERBIGUM FLASHING
GRAVEL STOP MEMBRANE
METAL GRAVEL STOP
FABRICATE SCUPPER
FROM SHEET METAL
FABRICATED COLLECTOR
BOX AND LEADER
i
NOTE
TRIM INSULATION TO PROVIDE POSITIVE DRAINAGE
P-22 OPEN SCUPPER
Ufedli C DoW wily I. 2004
J
.M
F15 ORGANIC
DERBIGUM FLASHING
FELT BACKER SHEET
MEMBRANE
(OPTIONAL)
STRIP SCUPPER WI
DERBIGUM FLASHING
MEMBRANE -EXTEND
TO FRONT EDGE OF
SCUPPER
DERBIGUM ROOF
MEMBRANE
ASPHALT PRIMER
SET SCUPPER IN
PLASTIC ROOF CEMENT
NAIL 3' O.C.
PERLITE CANT STRIP
SET IN BITUMEN
j
SYSTEM BASE PLY(s)
INSULATION AS
SPECIFIED
P-21 THRU WALL SCUPPER
_.. di,iy I, ZU04
v�roaxwa
0
GUTTER STRAPS
MIN. 2' GALMIZED
APPROX. 30' O.C.
NAILS 3' - 4' O.C.
METAL GUTTER WITH
METAL EDGE SET IN
METAL EDGE
PLASTIC ROOFING
CEMENT - PRIME
FLANGE BEFORE
INSIALLWION OF
ROOFING MEMBRANE
DERBIGUM ROOF
MEMBRANE RUN TO
FORWARD EDGE OF
TURN DOWN
METAL
MEMBRANE TO BELOW
WOOD BLOCKING
TURN DERBIGUM
MEMBRANE DOWN TO
BELOW WOOD
BLOCKING. EXTEND A
MINIMUM OF 12` ON TO
BASE SHEET SURFACE
SYSTEM BASE PLY)5)
NOTE:
THIS DETAIL SHOULD BE USED WHERE THE DECK IS SUPPORTED BY THE OUTSIDE
WALL, IT IS USED TO
RELIEVE STANDING NWERALONG THE ROOF EDGE. ALL ROOF SURFACES SHOUI D BE SLOPED TO DRAIN.
P-20 TWO-PIECE GUTTER DETAIL
_ifecuve Date July 1. 2004
11
0
DERBIGUM
CAST IRON STRAINER
I
FLASHING MEMBRANE - 36'
4�
4A LEAD FLASHING -
30' X 30' S IN
PEAFLAS OR
i
PLASTIC ROOFING
TAPERED STRIPS TO
CEMENT
PROVIDE 48' SQUARE
Y
DERBIGUM MEMBRANE
SUMP AREA
;,,: j j
SYSTEM BASE PIY(s)
UNDER DECK CLAMP
22 GAUGE CAST IRON
PLXE - 36' X 36'
CENTERED OVER
DRAIN
P-19 INTERIOR DRAIN PENETRATION
18 X 1/2' SHEET METAL
SCREWS, MIN. 2 PER SIDE
DERBIGUM MEMBRANE
STRIPPING. EXTEND MIN.4'
ONTO ROOF MEMBRANE
NOTE:
THIS DETAIL CAN BE MODIFIED FOR SINGULAR OR MULTIPLE PENETRATIONS.
0
24 GAGE G.I. CAP WITH
EXTENDED FRONT SIDE TO
FORM OVER
PENETRATIONS
24 GAGE G.I. CLOSURE
SET FLANGE IN A LAYER OF
PERFLAS OR PLASTIC
ROOFING CEMENT
CLOSURE MUST BE FABRICATED WITH ONE SIDE OPEN TO FIT AROUND PENETRATIONS WHICH CANNOT BE INTERRUPTED.
'OPEN' SIDE SHALL BE SEALED BY SOLDERING IN PLACE.
P-18 CONDUIT HOUSING
Effective Date July 1, 2004
Pi
*A,
rarforouxa
0
-15 ORGANIC DERBIGUM
FELT BACKER SHEET FLASHING MEMBRANE
(OPTIONAL)
DERBIGUM MEMBRANE
ASPHALT PRIMER
PERLITE CANT
STRIP SET IN BITUMEN
1 j
SYSTEM BASE PLY(s)
P-17 PENETRATION SPACING MINIMUMS
Effective Dow, .July f, 2004
ELASTOMERIC
SEALANT
DRPWBAND OR
UMBRELLA TO Sl
METAL PITCH P01
4' MIN. HEIGHT
4' MIN.FLANGE
IINSULNION AS
SPECIFIED
AL UMBRELLA/
PHERCAP
FLANGE CORNERS
3ET FLANGE IN
)LASTIC ROOFING
'EMENTAND PRIME
FOP FLANGE FOR
:LASHING
IBIGUM
SHING MEMBRANE
TBIGUM MEMBRANE
SYSTEM BASE PIY(5)
NOTE:
FILL PITCH PAN HALF WAY WITH NON -SHRINK GROUT AND REMAINDER WITH PERFLASH® OR ELASTOMERIC
SEALANT SLOPED AWAY FROM THE PENETRATION TO FORM AWATERSHED.
P-15 PITCH PAN DETAIL
Etiectice Uate July 1. 2004
�•�
0
ROLL LEAD FLASHING
MINIMUM 1' DOWN
PIPE
PLUMBING VENT
SIACK
DERBIGUM
FLASHING MEMBRANE
INSULWIONAS
SPECIFIED
DECK AS SPECIFIED
DERBIGUM MEMBRANE
SYSTEM BASE PLY(s)
NOTE:
SHEET LEAD MINIMUM OF 2 -112 POUNDS PER ROOF SQUARE,
P-13 VENT STACK DETAIL
Effective Date July 1, 2D04