Loading...
HomeMy WebLinkAboutroof wind pressure drip edge engineerC CLIENT: ADVANCED ROOFING, INC. PROJECT NAME: ISLANDIA CONDOMINIUM #1 PROJECT ADDRESS: 9550 SOUTH OCEAN DRIVE JENSEN BEACH, FLORIDA 34957 PROJECT DATA: SLOPE: B < 7 deg FLAT MEAN HEIGHT:z:= 197 ft WIDTH: Wa:= 60 ft. �Rb = 9ft. Wc:= 20ft. ENCLOSURE CLASS: ENCLOSED RISK CATEGORY: II PARAPET CONTINUOUS. 3 ft.? NO REGION: CENTRAL FLORIDA DESIGN WIND SPEED: L.= 163 MPH EXPOSURE: D TOPO. FACTOR: H / Lh < 0.05 USE K71:= 1.0 DIRECTIONAL FACTOR: Kd:= 0.85 DESIGN CRITERIA: FLORIDA BUILDING CODE 2017 Wind Design perASCE 7-10 Analytical Procedure DESIGN SCOPE: ROOF CLADDING ATTACHMENT Basic Combinations Sec 2.4 (Sec.2.4.1), is Wind Uplift, 0.6W Load Combination #7: 0.6W+0.6D Neglect Deadload - Use 0.6W Install DERBIGUM Roof System. EDGE ZONE MULTIPLIER: Trial Calculations: (3' min. ) z•0.40 = 78.8 Wa•0.10=6 Wb•0.10=0.9 Wc•0.10=2 Use Multiplier a:= 6 FT bc:= 3 ft. 2a = 12 FT 2bc = 6 ft. PROJECT DATA based on information provided by Client. U '®EY`' 'E CODE C ST. LUC 6RIP-EDGE j CONCRETE DECK: ROOF AREAS, _ r'A' MAIN ROOF I B & C: PENTHOUSES ,.-- --- --- VELOCITY PRESSURE qz 0.00256Kz•Kzt•Kd•V2 qz = 93.211 PSF Page 1 of 3 DATE: 02/03/2020 RE-CSI#: 20-023<ie zmin=7ft. 2 r z 11.5 Kz :^ 2.01.1 700) DESIGN VELOCITY PRESSURE Dqz := 0.6•gz D := 0A Dqz = 55.927 PSF 'COMPONENTS & CLADDING: EXTERNAL COEFFICIENT. GCp From Figure 30.6-1 i INTERNAL COEFFICIENT: GCpi Concrete Deck: GCpi = 0 = 1.612 CALCULATE UPLIFT PRESSURES: I pe'r ASCE 740 P Dqz•[(-GCp) + (GCpr)] FIELD PI D•qz•[(-1.4) + (-0)] =-78.297 PERIMETER P2:= D•qz•[(-2.3) + (-0)] =-128.631 CORNER P3:= D•qz•[(-3.2) + (-0)] -178.966 Cp, Reference PA 111 P:=D•gz•Cp PERIMETER UP P2U:= -128.6 psf OUT P20:=-128.61 psf CORNER UP P3U:=-179.0 psf OUT P30:= -179.0 psf ropy � r c REVIEWED FOR ®®E 'OMPLIA►NCE ST. LUCM COUNTY $R$®CC FL. Cert. of Auth. #32207 P Florida's Leading Roof Consulting Source Gi e... v{...,I !•....d:H.... C.-- . Rnnf A —I M...—wnhPrnommv . nnality A,a...... Insoections DRIP EDGE COMPONENT INFORMATION: EDGE MATERIAL: 24 GAUGE STEEL EDGE METAL: MAX LENGTH VERTICAL FACE: 3" FASTENER: 12 GA STEELANNULAR RING SHANK NAIL ANCHORED TO: TOP 3" MIN FLANGE OF GRAVEL STOP / DRIP EDGE METAL SECURED INTO DETERMINE FASTENER VALUE: (1) #12 GA RING SHANK NAIL / WOODBLOCK FAST. WITHDRAWAL RESISTANCE( 2of3 02/03/2020 tl#: 20-023-0e DR 2:1 min.) : := 231 = 2 LBF (2) #12 GA RING SHANK NAIL SHEAR RESISTANCE VALUE ( SAFETY FACTOR 2': 1 min.) : I�V2 120 _ 2 LBF (3) #12 GA RING SHANK NAIL PULLOVER RESISTANCE ( SAFETY FACTOR 2 :1 min.) : := 300 _ 2 LBF USE 1 FT. WIDE TO DESIGN, P (PSF) = P (PLF ) FS:=(p)•12 IUI.12=10.778 IpOI.12=13.997 IP2Ol•12=5.599 Ip UI •12=7.743 IP OI •12=10.056 IPy OI •12=4.022 S SPACING LIMITS GOVERNED BYRAS 111, SEC5.1. #12 GA RING SHANK NAIL: STAGGERED @ 4.0" O.C. EACH EDGE OF THE VERTICAL PERIMETER WIDTHS: a= 6 FT. b := 3 := 3 LENGTH OF CORNER ZONE 2a = 12 FT 2•b = 6 2•c = 6 The Roof Code Provisions in Ch.15 of the Florida Building Code 2014 Apply To This Work. FL. Cent. of Auth. #32207 Florida's Leading Roof Consulting Source 24 GA. STEEL DRIP EDGE 24 gauge steel gravel stop/drip edge 3" Min. T 1--'4" Ring Shank Nail Staggered: 4" O.C. REVIEWED FOR CODE COMPLIANCE ST. L�UCIE COUNTY I BOCC 311 3of3 02/03/2020 I I#: 20-023-0e