Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
roof wind pressure wood blocking engineer
REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY FL. CerL of Auth. 932207 BOCK/ Florida's Leading Roof Consulting Source 5oecification & Design • V isuaI ConA it i_an $gry ��s_•. Boor k�zvt Management Programs • Ouality Assurance Inspections ROOF WIND PRESSURE & ATTACHMENT DESIGN CLIENT: ADVANCED ROOFING, INC. PROJECT NAME: ISLANDIA CONDOMINIUM #1 PROJECT ADDRESS: 9550 SOUTH OCEAN DRIVE JENSEN BEACH, FLORIDA 34957 PROJECT DATA: SLOPE: 0 < 7 deg FLAT MEAN HEIGHT: z:= 197 ft (Penthouse C) WIDTH: Wa := 60 ft. Wb := 9 ft. We := 20 ft. ENCLOSURE CLASS: ENCLOSED RISK CATEGORY: II PARAPET CONTINUOUS. 3 ft.? NO REGION: CENTRAL FLORIDA DESIGN WIND SPEED: V := 163 MPH EXPOSURE:D TOPO. FACTOR: H / Lh < 0.05 USE Kzt:= 1.0 DIRECTIONAL FACTOR: Kd:= 0.85 DESIGN CRITERIA: FLORIDA BUILDING CODE 2017 Wind Design perASCE 7-10 Analytical Procedure DESIGN SCOPE: ROOF CLADDING ATTACHMENT Basic Combinations Sec 2.4 (Sec.2.4.1), is Wind Uplift, 0.6W Load Combination #7: 0.6W+0.6D Neglect Deadload - Use 0.6W Install DERBIGUM Roof System. EDGE ZONE MULTIPLIER: Trial Calculations: (Tmin. ) z10.40 = 78.8 Wa-0.10=6 Wb.0.10=0.9 Wo0.10=2 Use Multiplier a:= 6 FT be 3 ft. 2a = 12 FT 2be = 6 ft. r DECKS A-B-C VELOCITY PRESSURE qz:= 0.00256Kz-Kzt-Kd•V2 qz = 93.211 PSF Page 1 of 3 DATE: 02/03/2020 RECSI #20-023-wb-ABC EXPOSURE D zmin =7ft. PRESSURE COEFFICIENT 2 11.5 z Kz 2.01. 700 Kz = 1.612 DESIGN VELOCITY PRESSURE Dqz = 0.&qz D := 0.6 Dqz = 55.927 PSF MPONENTS & CLADDI EXTERNAL COEFFICIENT: GCP From Figure 30.6-1 INTERNAL COEFFICIENT: GCpi Concrete Deck: GCpi = 0 CALCULATE UPLIFT PRESSURES: (perASCE7-10) P:= Dqz'[(-GCP) + (GC'P4] FIELD P7:= D•gzr[(-1.4) + (-0)]=-78.297 PERIMETER P2:= D•qz-[(-2.3) + (-0)] =-128.631 CORNER P3:= D•qz-[(-3.2) + (-0)] =-178.966 Pl =-78.297 P2 =-128.631 psj P3 =-178.966 psj USE: WOODBLOCK DESIGN PRESSURE ATTACHMENT CRITERIA per RAS 111, Sec 3.3.1 PERIMETER AC2:= 250 PLF CORNER AC3 := 300 PLF DIV REVIEWED FOR !.ODE COMPLIANCE ST. LUCIE COUNTY IBOCC FL. Cert. of Auth. r32207 Florida's Leading Roof Consulting Source 5uelfication & Design • Visual Condition Su r>ers • Rnut X—, Al ,1 1ment Programs • Quality Assurance Insect oRt, ROOF WIND PRESSURE & ATTACHMENT DESIGN WOOD BLOCKING: Page 2 of 3 CONCRETE PARAPET DECKS A-B-C DATE: 02/03/2020 WOODBLOCK SIZE: 2" x 6" PT (min) FOR CONCRETE PARAPET RECSI #20-023-wb-ABC FASTENER: BASE WB: TFC WOOD -CONCRETE SCREW SUBSEQUENT WOODBLOCKS ANCHOREDTO: CONCRETE PARAPET TOP BASE & LOWER WOODBLOCKS DETERMINE WOODBLOCK DESIGN VALUE: FW 1600 (1 ) FASTENER WITHDRAWAL RESISTANCE-WB TO CONCRETE ( SAFETY FACTOR 4 :1 min.) : WR := 4 LBF (2) CHECK PULL -OVER VALUE -WOODBLOCK TO CONCRETE: PO:= 801 LBF < WR- 1.25 = 500 900 (3) CHECK SHEAR VALUE (t=1-1/2" )-WOODBLOCK TO CONCRETE: 2 LBF S = 450 231 (4) FASTENER WITHDRAWAL RESISTANCE-R.S.NAILTO WB ( SAFETY FACTOR 2 : 1 min.) :NWR := 2 LBF FOR DESIGN USE: FW := WR = 400 NWR = 115.5 TRIAL CALCULATIONS FOR FASTENER SPACING: FS:=(�W)•12 PERIMETER CORNER WR FS2 := I AC2I .12 = 19.2 WR FS3:= I AC3I • 12 = 16 NWR FSN := I AC2I ' 12 = 5.544 NWR M IAC3I •12=4.62 ENSURE ATTACHMENT WOODBLOCK INTO CONCRETE PARAPET TOP AS FOLLOWS ( REFER TOABOVE COMPONENT INFORMATION) CONCRETE ATTACHMENTS: PERIMETER: ATTACH WOODBLOCK TO PARAPET USING TFC WOOD -CONCRETE SCREW STAGGERED AT 18" O.C. CORNER: ATTACH WOODBLOCK TO PARAPET USING TFC WOOD -CONCRETE SCREW STAGGERED AT 12" O.C. WOODBLOCK LAYER ATTACHMENTS: PERIMETER & CORNERS: ATTACH ADDITIONAL WOODBLOCKS USING #12 GA. RING SHANK NAILS STAGGERED AT 4" O.C. MINIMUM PENETRATION=1-112" • USE 2 FASTENERS AT EACH BUTT END. ERIMETER WIDTHS: a = 6 FT. b:= 3 c:= 3 LENGTH OF CORNER ZONE 2a = 12 FT 2-b = 6 2-c = 6 i The Roof Code Provisions in Chapter 15, & RAS 111 of the Florida Building Code 2017 Apply to This Work. 04. cu t •fOi�r\L'�,oe. �eeeaa�«p0" IvC REVIEWED FOR CODE COMPLIANCE ST. LUCIE/+C/�OUNTY FL. Ceft of Auth. 832207 BOCC Florida's Leading Roof Consulting Source SoeCficafion & Des'gn . Visual Condition Surveys • Rouf ,X, tylanagement Programs. Oualily,essurance Inspections ROOF WIND PRESSURE & ATTACHMENT DESIGN WOOD BLOCKING: Page 3 of 3 CONCRETE PARAPET DECKS A-B-C DATE: 02/03/2020 RECSI #20-023Avb-ABC Packaging and Part Number Our WOOD -TO -CONCRETE screws are supplied in 100 piece cartons and includes the appropriate carbide tip concrete drill bit for optimal performance. P.N.: 014234HCKBLTS Technical Information Screw Size: 114 x 2-3/4" with Nail Point 1 5116' Hex Countersunk Material: C-1022 Carbon Steel i Case Hardened Finish: TRI-SEAL® Long -Life Coating. Formulated for use in treated wood. Corrosion Resistance: 1,000 hrs. Salt Spray perASTM 8117. No Red Rust Drill Bit Size: Use 3/16" x 4-1/2 Carbide Drill Bit Installation Tooling: Use hammer -drill to drill hole and install the screw.