Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSDA' FEES DUE: RECEIPT #: #: 17 Planning & Development Services Department Building & Code Regulation DivisionMOR � e 2300 Virginia Avenue N1�0 Ft. Pierce, FL 34982-5652 s SIP Tel. 7724624553 t L UCie G,O� APPLICATION FOR ROOF PERMIT my SEE REVERSE SIDE FOR INSTRUCTIONS 1. Location/Site Address: 2. Parcel ID Number: 396Z. Z oc► 1 • .. I 1 1 ' IM= I ..�' - ����''iii� [MIS 3. Description of Project or Work Activity: Qom; a u vP[ 4. Total Roof Area (square feet): 4 ow - 5. Roof Pitch: Ll / J Z 6. Type of Roof: [ Fiberglass Shingle [ J Concrete Roof Tile [ ] Wood Shake / Shingle [ ] Tar & Gravel I [ J Modified Bitumen [ ] Other [ ] Product Approval required for all types of Roofing Material (2 Sets) [ ] All Commercial Roofing requires design by, an Engineer or Architect (2 Sets) with Product Approval attached ** Roof Mitigation per F.S. 553.844 will be required. 7. 'Owner Information 8. Contractor Information Name: (_J � I k� It C- 4Z4 Address: f pZ 'N UU. 61-L&E i3oNn�H City: Ps'L State: Zip: -4 `iq g(. Phone: ?72 _37 2085' 9. Value of Construction: $ Sri- FL Reg/Cert #: C Cep 9 5 7 County Cert #: 16Z4q 1 Business Name: C As m a4C4 kW 10=2 ekl,fe, Cell Phone: -2-z 21 rL 90 147 **Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval. CONTRACTOR/OWNEWS AFFIDAVIT: I certify that all of the infiquiwtion contained in this application is correct and that all work will be done in oompG pica a egulating construction and zoning. PRIINT QUALI UMNOWNERS NAME 91—GNAIM OF QUALMOMMWMR t STATE OF FLORIDA, COUNTY OF c ACKNO ME THIS I C> DAY OF 2011 , BY O 15 PERSO TO OR HAS RODUCED AS IDENTMCATION �J "r ANGELA M. HUFF S1GNA F NOTARY TYPE O P NAME O NOTARY (Se My COMMISSION I EE 083530 ._ A EXPIRES: April 12, 2015 COMMISSION NUMBER Bonded Thtu Notary Public Underwriters NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR ATTORNEY BEFORE RECORDING -YOUR NOTICE OF COMMENCEMENT. Reviled 4/202010 INSTRUCTIONS ` Please complete all information in the space provided. All information must be printed (use black or blue ink only) ,or typed. This roof permit application is to be used only for those activities that are not otherwise included under a primary building permit. This application may not be' used for any activity that includes structural alteration' Building activities involving structural alteration, in addition to the roof work, must be permitted through the regular building permit review process. The information to be provided with this application includes: 1. Location/Site Address 2. Parcel ID Number 3. Description of Project or Work Activity 4. Total Roof Area 5. Type of Roof 6. Owner Information 7. Contractor Information 8. Value of Construction Indicate the street address or general location of the property where the building activity is taking place. Indicate the tax identification number of the property where the building activity is taking place. Completely describe the building activity to take place. Please indicate if tear -off or shingle over shingle etc. Indicate total roof area to be affected by this permit. Also indicate the pitch of the roof, expressed as a standard ratio of run rise. Indicate the type of roof being. repaired or resurfaced. Indicate the name and address of the owner of the property on which building activity is taking place. Indicate the State of Florida registration number (if applicable), St. Lucie County contractor license number and the name of the business doing the work. Indicate the total value of the work to take place. Total cost of construction includes all material and labor costs associated with the building/construction activity. Construction value is used to determine the permit fee. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction. This application can be submitted to St. Lucie County Building and Zoning, 2300 Virginia Avenue, Fort Pierce, FL 34982. All permit applications must be filled out completely before submission. No applications will be accepted. for p eessing_after 4:30 RK For assistance in completing this application, please call (772) 462-1553;° during regular office hours (8s00 AM = 5:00 PM), Monday through Friday. Upon issuaince''of this'per ait, required inspections can be scheduled by calling (772) 462-1261. St. Lucie County Roof Permit Application rev. 3/1/2009 JOSEPH E. SMITH, CLERK OF THE-rTRCUIT COURT - SAINT LUCIE COUNTY FILE # 3638409 OR BOOK 3332 GE 942, Recorded 10/18/2011 at 08:41 i. mod: 3beaodmiptadbsebjLinna>ritoetftiolprora�l�oc i�eea mdp VwW smd?[p• Wi*chaarc71?. E7o�ida slttds tbA �iwains t�f �6m it pnriani in melloEitii aC1a..meame� 1, v�v�rQ.�pidemiprion�ds�as.edle�i[�t.)•r�iowa�®aa �•1DZ- 4�dt o7��-oen/S _ rr, 1 0( - - ' -- L1�DIt4N iorotP :i1 i1 N _ ? PI cEoYL Sooi 7A) S Q'I �roko4r D iG WGyLaQ40u"Wi"6 14w�_o� Tb Eii�T6L3E5RLS 2 3. onsam um= a-'— I-Aj VL Iw tMM /k It5imkLe. J C-3c rl� T3nnln��i CT"PSL3��r,. arp"wW. u b.ss—• cZf IS7 ► I s. CVL- s�srg� G/t:aTerJ&.�-�tGus aop!e� %# tr 772 461-1nlllr�' - 3z7 L • A 2s&�ecz Z. - r=� aF,� ct i • 34,kgZ s. suamsaul"ADWMAM wnai*uttltttsAMUM4naQa: 6 ralminnruorSsuaa>sw>reoeat+w� . 7.Famsvi"tws`oetrA bdmipmodby0aa gmvhm=omenodardoonr®bmwbeewndupwidedby s.�oa.7uucnw� laal� SAD .AW �� : a6wo( hamsli "comploddodiosecd= 713.13p1(blpbtidaslrar�c . e..aran.anaas�:.asnuo� g.$pitadmd�leafootieadm®oeKma�t(ttieatpi�mdreslyl�esaa+�abbd�aoiesadsyae�tdma A. >sp�tmad0wara< Ptistltac�i �y's Ovnr'i Atilrrisd StarafFlaith . Of Sx- Lnr.?o. / 7 Ibe�repti��w dmoalCwbdbmalomb ` l d,d ©L� 20/ (»aid (brpo at ..a=. trmsR Womey b 13cU For Will,� A• �r,l c I hU nP[ (moo a[ptttgl m daioa rastlawle� - _pa�m8yl►m�uar padltoadlbteNaviy9�padidamibdlio¢ �✓I VEf Ltt:_ew � -2 . Yi IS tEEoettlt - (siprbsadNorfPaft) EWREB Jh"3,2013 WdWThru W"Ribk kdradOn b�+e>tad>ba>>ed%�tmoSmsinioisbaotatlrbatafnaY +� :i !Is<Ilanppaoa ar fOr �o®+unrsoNrr�h in..lyrvl.sipee�ff,— pl 1 � � l I.1�tA'.l1 ���d'ri1S I©WALE �. STATE 0f FLORIDA ST. LUCIE COUNTY THIS IS TOCERTIFYTHAT THIS IS TRUE AND CORRECT COPY OF THE ORIGINAL. n i09-EPA v SPO11�Ifs. CLEA Date: Planning-& Development Ser ices Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 772-462=2163 or 772-462-2172 - Fax: 772-462-6443 - ---- ---- - ------ - - --: __..--ROOF=1NSPECTLON-AFF:IDAVIT— - - - - - -- - - Re: Permit # I,.. S'► �ve,� ('K57-A0ec,2A�4 licensed as a( Contractor* -Engineer/Architect (Please print name &circle license type) *FS468 Buil ing Inspector *General, Building, Residential or Roofing Contractor or any individual certified under 468 F.S. to make such an inspection. On or about_ ID- LT- t ( , I did personally inspect the roof deck nailin>; (Date) work at: !7kO2— FE(rCoxzv e- : i kkeW fc-3��C (Job site address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S.) Signature and Seal License # STATE OF FLORIDAJ _ COUNTY 0F�L.-1.�C�� Sworn to and subscribe before me this day of 00:+_ 20 by 9'k-,e1 P_A lb Wally known to me or who h s produced identifil on. ,Notary Public,_State, of F__. ida. Signature of Notary: Commission Number: En 01/19/2011 (Seal) ANGELA M. HUFF MY COMMISSION # EE 08M EXPIRES: April 12, 2016 ' Pf;fi Bonded ihru Notary Public UnderMtem 'Ploricia Building Code Online Page I of 4 0 User Registration Hot Topics Submit Surcharge Stats & Facts Publications Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # Application Type Code Version Application Status Comments Arch ived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email FL10674-R2 Revision 2007 Approved Owens Corning One Owens Corning Parkway Toledo, OH 43659 (419) 248-7060 darrel.higgs@owenscorning.com Darrel Higgs darrel.higgs@owenscorning.com FBC http://www.floridabuilding.org/pr/pr app dtl.aspx?param--wGEVXQ�j,tDatBNbFY-5V%?.hnOTO/.?h6,,,,'7,h'D.-.I..,.,.,.,--ny -%,rxy Florida Building Code Online Page 2 of 4 Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Certification Agency Validated By Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Roofing Asphalt Shingles Certification Mark or Listing Underwriters Laboratories Inc. Robert J. M. Nieminen, PE Validation Checklist - Hardcopy Re( Standard ASTM D3161, Class F ASTM D3462 ASTM D6381, Class H ASTM D7158, Class H TAS 107 UL 2390, Class H http://www.floridabuilding.ortJpr/pr am dtl.asnx?naram=wGEVXOwt1)otRNhF.VSV%?.hn(1Ta/�?h6w7nhRPnT.z,.,-,,--DT vrT n ;, rioriaa building Lode Online Page 3 of 4 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved summary or Products Method 1 Option A 06/15/2009 06/16/2009 06/23/2009 08/11/2009 FL # Nodel, Number or Name 10674.1 Owens Corning Asphalt Roofing Shingles and Starters Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Refer to UL letter Description 3-tab, laminated, starter, ar Certification Agency Cert FL10674 R2 C CAC_AHJ_.IE Berman.pdf Quality Assurance Contra 10/01/2010 Installation Instructions FL10674_R2_II AH) letter Berman.pdf Verified By: Underwriters L Created by Independent Th Evaluation Reports Created by Independent Th Back Next DCA Administration http://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXOwtDcitBNbEY5V%2boOT%2b6w7ahRPulwvnvnrPT YNT 11111nin Florida Building Code Online Page 4 of 4 Department of Community Affairs Florida Building Code Online Codes and Standards 2555 Shumard Oak Boulevard Tallahassee, Florida 32399-2100 (850) 487-1824, Fax (850) 414-8436 © 2000-2010 The State of Florida. All rights reserved. Privacy Statement I Cogvright Statement I Accessibility Statement I Plug-in Software I Customer Product Approval Accepts: ® En qf�� VERWI► http://www.floridabuilding.org/pr/pr app dtl.aspx?Uaram=wGEVXOwtDotBNhF,YiV%)hnOTO/7h�.7,'7.1.D--T.....«......T7't �, .,. TGDY.R19380 Prepared Roofing Accessories Prepared Roofing Accessories See General Information for Prepared Roofing Accessories OWENS CORNING R19380 1 OWENS CORNING PKY TOLEDO, OH 43659 USA Asphalt underlayment accessories, "WeatherLock@G", "WeatherLock Cold Climate", "WeatherLock@Mat", "WeatherLock@P", "Weatherl-ock@PM", "Starter Shingle", self -adhered or nail down for use in the installation of Class A asphalt glass fiber mat shingles and Class C asphalt organic felt shingles. "WeatherLock@ Metal" self -adhering modified bitumen membrane for use in the installation of Class C metal shingles. "WeatherLock FLEX", self -adhering modified bitumen membrane, for use in the installation of Class A asphalt glass fiber mat shingles and Class C asphalt organic felt shingles. "Fiberglas Reinforced Felt". An asphalt saturated organic felt for use in the installation of this manufacturer's Class A asphalt glass fiber mat shingles and Class C asphalt organic felt shingles. "Fiberglas Reinforced Felt" can also have the adjunct statement - Also Classified In accordance with ASTM D6757. Last Updated on 2008-07-29 Questions? Notice of Disclaimer Page Too Copyright l7 2008 Underwriters LLbora on a rnc_ @ The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow -Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (flies) must be presented in their entirety and in a non -misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright © 2008 Underwriters Laboratories Inc.@" An indaDendenl •),Uan1ldl1On wjIktnq I o r a safer %aotId �rilh 111l0gfIty. pre1.1S1On anti knewl0J40 Underwriters Laboratories Inc.:: June 9, 2009 Mr. Darrel P. Higgs Owens Corning World Headquarters One Owens Corning Parkway, 2A Toledo, OH 43659 Our Reference: R2453 Subject: Shingle Starter Dear. Mr. Higgs: Northbrook Division 333 Plingsten Road Norihhrook. IL 60062-2096 USA VAIMAIl.cam tel 1 847 272 8800 lax• 1 847 272 3129 CuSlnrner sarvice: 1 877 85.1 3577 This is to confirm our phone conversation that, Owens Corning's Starter Strip Shingle, is now known as "Starter strip PLUS" Shingles. These products have met with ANSI/UL790 Class A, ASTM D3462, CSA 123.5 and ASTM D3161 Class F. These products have been tested and meet the criteria for these standards and are covered by UL's Follow -Up Service Program for File R2453. If you should have any questions, please feel free to contact the writer. Very truly yours, Martin K. Rowan (Ext. 42349) Senior Project Engineer Fire Protection Division r, p, r u r u i a n r �I tl _ �I i t7 n i l :1 .� i •r i n I. I. Application Instructijgins B afDvz installing this product, check local building codas for their roofing requirements. These shingles are designed for new or raroofing work over any properly built and supported wood roof deck having adequate nail holding capacity and a smooth surface. Check local building codes. precarutjonary Na'ta: The manufacturer will not be responsible for problems resulting from any deviation from the recommended application Instructions and the following precautions: Roof Top Loading: Lay shingle bundles flat Do not bend over the ridge. Roof Deck: • 6" Maximum roof deck boards • Minimum'/a" plywood - Minimum %4" OSS Regardless of deck type used, the roofing installer must; I. Install the deck material in strict compliance with the deck manufacturer's instructions. 2. Prevent the deck from getting wet before, during and after installation. Ventilation: Must meet or exceed FHA Minimum Property Standards. Handling: Use extra care in handling shingles when the temperature is below 40°F. Storage: Store in a covered ventilated area at a maximum temperature of I10•F. Stack in a flat fashion (maximum of 16 bundles high). Protect shingles from weather when stored at the job site. Do not store near steam pipes, radiators, etc. (Nails must be corrosion -resistant, I I. or 12•gauge, with heads at least 'A" in diameter. Staples must be 16-gauge minimum,''/4" minimum crown width, and sufficient length to penetrate'/4" into wood decking or through APA rated roof sheathing. Staples are to be corrosion -protected. Properly Driven Improperly Driven W min. Decking tif" •"diameter Shingly All Fasteners must penetrate at least'/" into the wood deck or completely through sheathing. Notice: Owens Corning recommends the use of nails as the preferred method of attaching shingles to wood decking or other nailable surface. Caution: IRocf surface may be slippery, especiaily when wet or icy. Use a fall protection systam when installing, Wear rubber -soled shces.Walk with care. Falling Haaard: secure area below work and mataria!s on roof. Unsecured matarWs may slide on roof. Place on level plane or secure to prevent sliding.Wyear a hard hat listruccl031e3 de apilC20611 Antes de instalar ante producto, corsulta los cadigos d, construction locales para iniormarse sobre Jos requisites detechado. Estas tajas han sido diseAadas para la construction de techos nuevos o el arreglo de techos existentes sobre estructuras de madera construicias correctamente y clue poseen una capacidad adecuada de sujeci6n de cavos y una superficie lisa. Consulte Jos cadigos de construcci6n loeaiies. tNota de prec2uclahs El fabricante.no sera responsable de problemas clue sean consecuencia de no seguir exactamente las instrucciones de aplicac16n recamendadas y las siguientas precaueimnes: Carga sobre tacho: Coloque los paquetes de tajas de manera Plana sobre el tacho. No los doble sobre la cumbrera. Superflcle del tacho: • Tablas de superficie de techo de 6 pulg, miximo - % pulg. Como minimo de madera terciada •'/ie puig. Como minima para pantiles de fibra orientada Cualquiera sea el tipo de superficie utilizada, el instafador debe: I. Instalar el material de la superficie sigulendo estrictamente las instrucciones del fabricante de la superficie. 2. Evltar qua la superficie se mole antes. durance y despu6s de la instalaci6n. Ventllacl6n: Debe cumplir o excader las normas minimas para propiedades establecidas por el FHA Manipulaci6n: Tenga mucho cuidado al manipular las tajas cuando la temperatura sea Inferior a los 40°F. Almaeenaje: En un irea cub!erta y ventilada a una temperacura no mayor de I10eF. Apilar de manera plana (un miximo de 16 paquetes de altura). Proteja las tejas del clima cuando las almacene en el lugar de trabajo. No las almacene Carta de tuberlas de vapor, radiaderes, etc. Los elavos deben ser inoxidables, de calibre 11 6 12, con cabezas de por to menos'/j puig. de diimetro. Las ,arapas deben ser, como minimo, de calibre 16, con unancho de corona de al menos's/6 puig. y una longitud suficiente Para penetrar'/+ puig. en la superf tie de madera o a traves de un revestimiento de techo que cumpla con las normas APA. Las grapas deben ser inoxidables. Bien calacado Mal colocado dlimatro min. entablonado Apuig. ei-%puig. Tale % puig. H puig. min. Todos los sujetadores deben penetrar al meros'/ pu!g. an la superficie de madera o atravesar ccmpleramente an Jos recubrimientos de madera terciada. Aviso: Owens Corning recomienda el use de c!a,/os como m6tado prafarido para filar t_>jas a superf:cies da madera u otras superf:cias aptas pars elavos. El Cuidado: El tacho puede estar resbaloso, especialrnente cuando aszi mojado o helado, Utilica un sistama de protec- ci6n contra caidas durance la instalacion. Use zaoatos de hule, Camine con culdado. Pel!gro de caida de objetos: Por favor asegure el area que se encuentra debajo de la zona de trabajo y amarre los mntp Al 1.e of #­kI I n- ..--4-,.:-1-.....- __ ­.. _.., . Spea:i2l9:y Eave Rashing; ,o WeatherLock' Underlayment or equivalent eava and flashing mernbrane applied to a point at least 241t beyond interior wall line. See manufacturer's Installation instructions. See Fig. 1, Underlayment: Standard Slope (4" in 12" or more) Application of underlayment, metal drip edges and eave flashing - See Fig. 2. Low Slope (2n in 12" to less than 4" in IT) Application of underlayment and metal drip edges: See Fig. 2A. Chalk Uses: To aid in shingle alignment, it is recommended chat chalk lines be srapped on the exposed surface of the underlayment prior to shingle applicacicn. See Fig. 3. Specialty Eave Flashing Fig2 Ravestfmiento especial Para alero Eaves flashing where required Da a1Ho, donea w necasano reh 24' 3evond ieredm —� wad Gna 2I putg. maY adl de la linty inrema depared Wadrme Linea de pared 2 Underlayment Standard Slope Pendiente estandar del lmpermeabRizante Slapes C 1n 12' or none Pendlentes de 4 pulp. cads 12 pulp. o m!f Drip Ldgs — "offs" and Waaneruce at rake edge Bardir de pares sabre Wathertace y in bards do ufga inciesate Tp1w superpodddn suprrisr, ]pulp. tr mln.End hp uly. Suparpt 1fiaC (pulp. aim Vertical ssama a' min. WatharbcN over drip edge at save WeathatUck' sobm bards do gotta in d darn FibJj Underlayment tow Slope t A Pendiente bala del impermeabilizanta Slapse r in 12* to lea thane a 1r• Pendrenhas do 2pdo, coda 12 pulp., testa merles de! pulp. ads 12 pulp. Venial toms /lS� _ �► b' min. ado edge — II over 'Neather{aep B it is edge garde de ga a —WeatharLocN robra'waattwLos, :n horde de wer drip edge st:eve indimde '� Wsadtertccka g� Tap hp b' min. End lap 9at�m , do ea Nder: Supnpadcfdo Snpupasiddn RnsC kpulg. nut. supariat rpulo. Chalk Lines Uneas de tiza Ravest:3r"9k 1e73o espeglal Para alar�p; Mernbrana autnadhesiva ` eatherl.act.•'' o membrana equivalenta para alero y bawd`, aplicada en un punto al rnenos 24 pulp. mas ally de la Linea .de la pared interior. Consulte las instrucciones de instalaci6n dal fabrieante. Consulte la Fig. I. Impermeaibllizantso Pendiente estandar (4 pulg. cads 12 pulg, o mas) Aplicaci6n de impermeabilizante, bordes de goteo metalicos y revestimiento del alero: Consute la Fig. 2. Pendiente ibaja (2 pulg. en 12 pulg. a menos de 4 pulg. en 12 pulg.) Aplicaci6n de impermeabilizante y bordes de goteo metalicos: Consute la Fig. 2A. Uneas da tiza; Para facilitar Is alineac& de Las tejas, se recomienda hater marcas de tiza (utilizando sagas imoregnadas en Liza) sobre la superficle expuesta del impermeabilizante antes de colocar las cejas. Consulte la Fig. 3. 3hi'-rigle Fastening; Standard Fastening Pattern Fasteners must be placed in the SureNaila fastening area. See Fig. 4. Six Nail Fastening Pattern For 6 nail fastening pattern. See Fig. 4. Mansard or Steep Slope Fastening Pattern Fasten between SureNail area and top of cut out. See Fig. 4A. REQUIRED: For slopes exceeding 60 degrees or 21 inches per foot, use six fasteners and four spots of asphalt plastic cement per shingle. Apply immediately; one I"diameter spot of asphalt plastic cement under each shingle tab. Center asphalt roof cement 2"up from bottom edge of shingle tab. Roof Cement where required must meet ASTM D-4586 Type I or II (Asbestos Free). Fig Standard Fastening Pattern , Esquema de fijacicin estindar ! Nail Pattam c;quema de J clavor Sur#Ja'P fastening area :vidth Am de c4ror sun:llar 5%-Eapawit Ma a, SrA'Eapawn 54Pulg.drvoosiddn clavor Slipulg.d.erporlddn ISix Nail fastening Pattern Esquema de fiiacidn de sais clavos S Nail Pattern Esquema do a lava SuteNaar fastening ana width Am drdaraa Sun miP .�—b4 •'mis �_ _ TA-Erpown Nay s'A a/ .dear odddn clavor SYr' Ldj. doe P e P s+Apdg. dr eaporrddn I �� Mansard or Steep Slope Fastening Pattern t Esquema de 1ljadin pan mansaidas o pendlentes agudis a Nail 6luadea,er tq. Pattern hsa.t„r,w 6.wiP uem� is71,14 au W ne daawt ,huMrrrdae,r de a claroa arrmr rrtmrrae. d e . . urz..w�rroe.v '� ywirelnmrti _ e.a a ax t' tr } ir�'s:r .''��. •..mis'.:, S'A' Espasufe Nail SSP Eaporum S'A pulp. de vpodddn darer $SS pulp, do aapoddda 3hirl9le A} pilicatlan: These shingles are applied with a 6'/," offset, with Ss/e" exposure, over prepared roof deck, starting at the bottom of the roof and working across and up. This will blend shingles from one bundle into the next and minimize any normal shade variation. Application with offsets of 4" or 5" are also acceptable. Caution must be exercised to assure that end joints are no closer than 2" from fastener in the shingle below and that side laps are no less than 4" in succeeding courses. Refer to course application steps for specific instructions. (continued cn next page) FI)atiba de tzj33: Esquema de fajacion ast_ndar Los sujetadores se deben cofocar an el area de sujeci6n SureNail' Consulte la Fig. 4. =squema da fijacion de sais cle.•vos Para un esquema de fijacion de 6 clavos. Consulte fa Fig. 4. Esquema de fijac16n en pendientes pronuncladas o mansardas Filar entre el area SureNail y la parze superior del recorte. Consuhe la Fig. 4i1. REWISITOS: Para pendientes de mis de 60 grados o 21 pulg. par pie, utilice seis sujemdores y cuatro pequenas cantidades de cemento plistico asfaltado por tela. Inmediatamente, aplique una pequena canddad de cemento plistico asfaltado de I pulg, de diimetro debajo de cads lengiieta de las tejas. Asegtirese de que el cemento plistico asfaltado este centrado 2 pulg. por encima del borde inferior de la leng0em de la teja. Cuando sea necesario utilizar cemento para techos, dste debe cumplir con la norma ASTM D-4386 Tipo 16 it (sin asbestos). Apilicaci®n de alas tajms: Estas tejas se aplican con un desplazamiento de 6'A pulg., con una superficie expuesta de 5% pulg., sobre estructuras base de techos preparadas. La colccacibn comienza por la paste inferior del Cacho y se realiza en forma transversal hacia arriba. De esta manera, las tejas de un paquete se mezclan con las del siguiente y se reducen al minimo las variac!ones normales de tonalidad. Tambien se pueden aplicar tejas con un desplazamiento de 4 6 5 pulg. Aseg6resa de qua las uniones de los extremos no se encuentren a menos de 2 pulg. del sujetador de la teja qua se encuentra mis abajo y qua las superposiciones laterales no sean de menos de 4 pulg. an las hileras siguientes. Consults los pasos de aplicaci6n de hileras para ver las instruccicnes especificas. (continua an la pigina siguiente) Shingle AkPPISCation Starter Course: Use starter roll or trim SIA" from the starter course shingle. Trim 6%" off the rake of the starter course shingle and flush with the drip edge along the rake and eaves edge, and continue across the roof. Use 5 fasteners for each shingle, placed 2" to 3" up from eaves edge. See Fig. S. (If no drip edge is used, shingles must extend a minimum of/%" and no more than I" from rake and e31es edge.) First Course: Apply first course starting with the full shingle even with the starter course. See Fig, SA. Fasten securely according to fastening Instructions. See Fig, 4. Second Course: Remove 6%" from the left end of this shingle and apply the remaining piece over and above the first course shingle and flush with edge of the first course with SW exposure. See Fig. S& ' Fasten securely according to fastening instructions. See Fig. 4. Third Course: Remove. 13" from the left end of this shingle and apply the remaining piece over and above the second course shingle flush with edge of the second course with 5s/" exposure. See Fig. SC. Fasten securely according to fastening instructions.. See Fig. 4. (continued on next page) Fig,5 Shingle Application Aplicacidn de tajas Stanor Caurso Hiles inicial Rake Edge . Horde de viga incdnado Trim 6%* from left edge Trim 5'4' Recomr 9Aping. rid fib' from fmm edge bade izquimdo Rera W a Apulg. del . .. bode dWnnm Shingle Application :!go �� Aplicacidn de teias nrstCauno PrimeraWers Akplicaci-in de 123 Hilerz inicial: Utilice un rollo de inicic o corta a 5s/a pulg. de la teja de la hilera inicial, de manera que el sellador este alineado con el borde del alero. Corte 6%2 pulg. desde la viga inclinada en la teja de ►a hilera inicial y extienda. M$s ails de la viga inclinada y el borde del alero, y continue a to ancho del techo. Utilice 5 sujetadores para cada teja, colocados a una distancia de entre 2 y 3 puig. del horde del alero. Consuhe to Fig. S. (Si utiliza un borde de gotao, las tejias deben extenderse un minir'no de '/2 pulg. y un maxirno de I pulg. de la viga inclinada y el borde del alero.) Prlmera hilera: N4�.da• ,. 4. Coloque la primera hilera comenzando Rake Edge -- con la teja cortada alineada con la md do "'An "'°' ,� _ hilera inicial. Consulte la Fig. SA. 'o; Sujete flrmemente de acuerdo con :. las instrucciones de sujecidn. Consuhe la Fig 4. Segunda hilera: Shingle Application Figs 5B Aplicacidn de teias Quite 6%: pulg, del borde izqulerdo de esta teja y aplique la pieza restante sabre y por encima de la teja de la seeandCaar:. primera hilera y al ras del borde de segundohifert la primers hilera, con 5r/e pulg. de a h 0pv ,. exposici6n. Consuhe la Fig. 58, lea w,- Sujete firmemente de acuerdo con ' ;;'r las instrucciones de sujecidn. Rake Edge lards, do vlga add Consuhe fa Fig. 4. indlnada Tarzara hilera: Trim B'h' r'• 6�,.4.; ,.. hob Heir edge j•, ° s%'@dpawn `s.. Quite 13 pulg, del borde izquierdo de Reearcu 6?4P'd9 del yard. aquf. 5!kpulg. ds, e.rpdaieida esta teja y aplique la pieta resmnte sobre y por encima de la teja de la segunda hilera y al ras del borde de Shingle Application Fig�� r Aplicacidn de teias la segunda hilera, con 5% pulg, de ex osicion. Consuhe la Fi p i'• SC Sujete firmemente de acuerdo con Third Caune las instrucclones de sujecion. Tercorahilera ` ai9 cikte , Consuhe !a Fig. 4. g, �toya'en''Z.,:. (ccntintia en la pigina siguiente) Rake Edge large de viga r e� • r: ��. illdinada Nm 13' hob ` / :•\ "c'}' left edge \ Reaertar .. 13 pule. del borde Lpierdo da.e+aaae a':+��aaS2dbd®TJ (i;i��1'Se): Fourth Coursa: Remove 19%ir from the left end of this shingle and apply the remaining piece over and above the third course shingle and flush with edge of the third course with SW exposure. See Fig. SD. Fasten securely according to fastening instructions. See Fig. 4. Fifth Course: Remove 26" from the left and of this shingle and apply the remaining piece over and above the fourth course shingle and flush with edge of the fourth course with SYs" exposure. See Fig. SE Fasten securely according to fastening Instructions. See Fig. 4. Sixth Course: Remove MS" from the left end of this shingle and apply the remaining piece over and above the fifth course shingle and flush with edge of the fifth course with 5W exposure. See Fig. 5F Fasten securely according to fastening instructions. See Fig. 4. Succeeding Courses: For succeeding courses, repeat first through sixth course. See Fig. Sc. Shingle Application Fig. 5D Aplicacidn de tejas Fourth Ccune C11an9 hilera X"a V n `cs�'Sd,N ,Ye. Nab e \ ve; Rake Edge \� • .� § i C�1�.'';: indinaaa ��b" Ulm :Frg 19'h' ham left edge• R—rar 19'dpulg. dal borde mlerdo as Shingle Application 0191 5E Aplicacidn de Was Ffth cause 0ulntahilera akdpee"NI Raira Edge, nor Artado " ego .........Y> ' Trim 29' fmm 4h edge Recorw 29palg. del bards kWordo FigC Shingle Application . J Aplicacidn de tejas swli caung Soap More Sd N' ��aa e1�� � �pd • '„� �s *Goo u • (y' .. '=fie: .�� �.y � t, . . .' :$ " r. '$..... ..g� Trim32.Yhom fah edge 'y Raortar 32%pule. del bordekgeienda �jA Shingle Application I G Aplicacidn de Was Succeeding Counee Hileras siguievrtoa :AplicadAn de las tajaz Cuarta hilera: Quite 19'/z pulg, del borde izquierdo de esta teja y aplique la pieza re$tante sabre y por encima de la teja de la cercera hilera y al ras del borde de la tercera hilera, con 5%a pulg. de exposic16n. Consuke la Fig. SD. Sujete firmemence de acuerdo con las instrucciones de sujeci6n. Consuhe to Fig 4. Quinta hilera: Quite 26 pulg, del borde izquierdo de esta teja y aplique la pieza restante sabre y par encima de la teja de la cuarta hilera y al ras del borde de la cuarta hilera, con SSS/e pulg. de exposici6n. Consuke la Fig. SE Sujete firmemente de acuerdo con las instrucciones de.sujeci6n. Consuke la Fig. A Sexta hilera: Quite 32% pulg. del borde izquierdo de esta teja y aplique la pieza restante sabre y par encima de la teia de la quinta hilera y al ras del borde de la quinta hilera, con S% pulg, de exposici6n. Consuhe la Fig. 5F. Sujete firmemence de acuerdo con las instrucciones de sujec16n. Consuke la Fig. 4. Hileras siguientes: Para las hileras siguientes, repita Jos pasos que se indican desde la primera haste la sexta hilera. Consuke la Fig. 5G. Malley C-onstrunti'Dn-. Closed -Cut Valley See Fig. 6. A closed -cut valley can be used as an alternative and is applied as follows: Lay a 36"-wide valley liner of self - adhered membrane underlayment or equivalent. A 36"-wide minimum SO -lb. smooth surface roll roofing can also be used as a valley liner. Lay all shingles on one side of valley and across center line of valley a minimum of 12 Fasten a minimum of 6" away from cancer line on each side of valley. Strike a chalk line 2" from the center line of the unshingled side. Apply shingles on the unshingled side up to the chalk line and trim, taking care not to cut the underlying shingles. Clip upper corners of these shingles, cement and fasten. Both woven and metal valleys are acceptable alternatives. Step Flashing-. Use 10" x 7" corrosion -resistant metal where roof planes butt against vertical sidewalls or chimneys. See Fig. 7. Hip & Ridge Api✓3§gatjtn9. Use High Ridge Hip a Ridge shingles. Follow application instructions as printed on the High Ridge Hip 8 Ridge carton. See Fig. 8. No6 Closed -Cut galley Construction ya Ccnstrucci6n con canal da torte carrado l vauey Unef —I ROvWinieno ilmv INund it Unde,bvment ldsm6nna a impermoa6duanyrr /��' cahteffim Lima ®opal F, 1 Step Flashing gt Escalonado Min. -nino Ca�st;•a�gg9�n del sana]: Canal con carte carrado Consuhe la Fig. 6, Coma altarnaciva, se puede utilizar Esv'a !lea clava ero^d una limahoya con canal cerrado qua Asphah Roof Camem Cemento pan txhas de sslano se aplica de Is siguiente manera: I'llColoque �11—torcarnts"i un revestimiento de limahoya Rarrrar n ins de impermeabilizanta de membrana autoadhesiva o equivalente de 36 ping de ancho. Para revescir la limahoya, tambien se puede utilizar un rollo de ` yx. techado de superftcie lisa de 36 pulg, de ancho y un minima de SO libras. Coloque codas las celas sobre un lado del canal y a traves de la linea central del canal al menos 12 pulg. Sujete a un minimo de 6 pulg. desde la Ifnea central a cada lado del canal. Marque una linea de tiza a 2 pulg. de la lines central del lado qua no tiene tejas. Coloque las• tejas del lado que no Ilene tejas hasta la Ifnea de tiza y recorte, con cuidado de no cortar las tejas que se encuentran debajo. Una los extremos superiores de estas tejas, coioque cemento y sujete. Se pueden utilizar canales de teildo o metal. Y tap lap BuPerpon'adn Metal flashing n+penar do2pulp. 10"sT ;c NO fleshing to foal, Matallca do al Nrhe ro pulg, a) pu1g,Ft Fsevestietaineta escalonade: Utilice metal resistente a la corrosion de 10 x 7 pulg, an los puntos an Jos que los planes del tncho se unan a las parades laterales verticales o a chimeneas. Consuhe la Fig, 7, F' D Hip & Ridge Application COIQgac';6n de raballetzs y t Preparation de las teias Para caballetes y cumbreras 49 curbs;ass Frevading'Nlnd Olncdon Dirxcidn predomNante dal viemo 7• uig. n Gulg, 8 d. aaat� Utilice tejas para lima tesa y cumbrera. Siga las instruccior,es de colocaci6n del envoltorio. Consuhe la Fig. 8. V Fattening Dispnee Distantia ds hJacidn, 9 ping. Florida Building Code Online z Page 1 of 5 FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature 10 0ZZ7 )t Topics Submit Surcharge Stats & Facts Publications FBC Staff 131 :ion Search > Application List > Application Detail FL5259-R10 Revision 2007 Pending FBC Approval POLYGLASS USA 150 Lyon Drive Fernley, NV 89408 (720) 279-2348 jarnold@polyglass.com Jim Arnold jarnold@polyglass.com http://www.floridabuilding.orglnr/i)r ann dtl.asnx?nara.m=wCTF.VXnwtT)nvhcn A --'%T4T T-4: TIT TTT Florida Building Code Online Page 2 of 5 Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By James Arnold, PE, RRO 10475 Park Meadows Drive Suite 600 Lone Tree, CO 80124 (720) 279-2348 jarnold@polyglass.com Amir Khan 621 Snively Avenue Winter Haven, FL 33380 (866) 802-8017 Ext 238 ajhan@polyglass.com Roofing Underlayments Evaluation Report from a Florida Registered Ar Florida Professional Engineer Evaluation Report - Hardcopy Received Robert Nieminen PE-59166 Underwriters Laboratories Inc. 11/30/2012 John W. Knezevich, PE http://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDQvbSQAaZn3Crk2vS%2fea01inp-inai%2bZPLoQV6TTrfnKTJTT.._ 7/16/2010 Florida Building Code Online Page 3 of 5 Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Validation Checklist - Hardcopy Received FL5259 R10 COI Trinity ERD CI - Nieminen.p Standard ASTM D 1970 ASTM D226 ASTM D6164 ASTM D6222 ASTM G 154 ASTM G155 FM 4470 Method 1 Option D 06/25/2010 06/28/2010 http://www.floridabuildin2.orv/nr/nr am dtl.asnx?naram=wGFVXOwt.DovbgnAa7.nICrk?.vQ%9.fPn(llinoirnni%,7h7.PT naV6T TrfnKT TTT '711 C%001 0 Florida Building Code Online Page 4 of 5 Date Pending FBC Approval 06/30/2010 Summary of Products FL # Model, Number or Name Description 5259.1 Polyglass Roof Underlayments Roofing underiayments Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-135 Other: The design pressure in this application relates to direct -bonding to plywood deck. Refer to ER Section 5 for other limits of use. Installation Instructions FL5259 R10 II er062510FINAL PC UNDERLAYMENTS FL5259-R10.pdf Verified By: Robert Nieminen PE-59 Created by Independent Third Party Evaluation Reports FL5259 R10 AE er062510FINAL P UNDERLAYMENTS FL5259-R10.pdf Created by Independent Third Party Back Next Department of Community Affairs Florida Building Code Online Codes and Standards 2555 Shumard Oak Boulevard Tallahassee, Florida 32399-2100 (850) 487-1824, Fax (850) 414-8436 © 2000-2010 The State of Florida. All rights reserved. Privacy Statement I Copyright Statement I Accessibility Statement I Plug-in Software Product Approval Accepts: Customer Service E http://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDavbSaAaZn3Crk2vS%2fea01iDQinai%2bZPT.ogV6T IrfnKT ITT... 7/16/9.01() Florida Building Code Online Page 5 of 5 9�f http://www.floridabuilding.orp/-Pr/pr apt) dtl.asnx?naram=wGEVXOwtDavbSoAaZn3Crk2vS%2fea01ingina.i%2bZPT.ogVF1TrfnKTTTT.. 7/16/9.010 EXTERIOR RESEARCH & DESIGN, LLC. ,• i Certificate of Authorization #9503 g�p 353 CHRISTIAN STREET, UNIT #13 -..t T�,16 �t�� ERD OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT Polyglass USA, Inc. Evaluation Report P12060.02.09-R5 150 Lyon Drive FL5259-RIO Fernley, NV 98408 Date of Issuance: 02/24/2009 Revision 5: 06/25/2010 SCOPE: This Evaluation Report is issued under Rule 9B-72 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2007 Florida Building Code sections noted herein. DESCRIPTION: Polyglass Roof Underlayments LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinityl ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 9. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 06/25/2010 This does not serve as an electronically signed document. Signed, sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. TrinitylERD is not owned; operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. t ROOFING COMPONENT EVALUATION: 1. SCOPE: TRINITY ERD Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Roof. Underlayments, as produced by Polyglass USA, Inc.,, have demonstrated compliance with the following sections of the Florida Building Code (non-HVHZ) through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.4, 1507.2.9.2, 1507.3.3, Physical Properties ASTM D1970 2001 1507.5.3, 1507.6.3 1507.2.3, 1507.3.3, 1507.5.3, Physical Properties ASTM D226 1997 1507.7.3, 1507.8.3, 1507.9.3, 1507.11.2 Physical Properties ASTM D6164 2000 1507.11.2 Physical Properties ASTM D6222 2002 1504.6 Accelerated Aging ASTM G154 2000 1504.6 Accelerated Aging ASTM G155 2004 1504.3.1 Wind Uplift FM 4470 1992 3. REFERENCES: Entity Examination Reference Date PRI (TST 5878) Physical Properties PRIO1111 04/08/2002 PRI (TST 5878) Physical Properties PUSA-005-02-01 01/31/2002 PRI (TST 5878) Physical Properties PUSA-013-02-01 12/23/2002 PRI (TST 5878) Physical Properties PUSA-013-02-02 12/23/2002 PRI (TST 5878) Physical Properties PUSA-013-02-03 12/23/2002 PRI (TST 5878) Physical Properties PUSA-018-02-01 07/14/2003 PRI (TST 5878) Physical Properties PUSA-028-02-01 07/13/2005 PRI (TST 5878) Physical Properties PUSA-033-02-01 01/12/2006 PRI (TST 5878) Physical Properties PUSA-035-02-01 09/29/2006 PRI (TST 5878) Physical Properties PUSA-055-02-02 12/10/2007 PRI (TST 5878) Physical Properties PUSA-061-02-02 01/28/2008 PRI (TST 5878) Physical Properties PUSA-076-02-01 02/22/2008 PRI (TST 5878) Physical Properties PUSA-083-02-01 04/14/2008 PRI (TST 5878) Physical Properties PUSA-088-02-01 07/29/2009 MTI (TST 2508) Physical Properties JX20H7A 04/01/2008 MTI (TST 2508) Physical Properties RX14E8A 01/29/2009 ERD (TST 6049) Physical Properties 11752.09.99-1 02/08/2000 ERD (TST 6049) Physical Properties 02200.07.03 07/14/2003 ERD (TST 6049) Physical Properties P5110.04.07-1 04/11/2007 ERD (TST 6049) Physical Properties P13450.08.09 08/13/2009 ERD (TST 6049) Physical Properties P33360.06.10 06/25/2010 ICC-ES (EVL 2396) IBC Compliance ESR-1697 01/01/2005 ICC-ES (EVL 2396) IBC Compliance ESR-1160 03/01/2005 Miami -Dade (CER 1592) HVHZ Compliance NOA Current Polyglass USA Manufacturing Affidavit Products Current 02/18/2009 Polyglass USA P/L Affidavit Mule -Hide Cross Ltg 03/01/2008 UL (QUA1743) Quality Control File No. R14571, Vol 1 Exp. 11/30/2012 Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R5 Certificate of Authorization #9503 FL5259-R10 Revision 5: 06/25/2010 Page 2 of 9 ERD TRINITY 4. PRODUCT DESCRIPTION: 4.1 Mechanically Fastened Underlayments: 4.1.1 ELASTOBASE is a fiberglass reinforced, SBS modified bitumen base sheet. 4.1.2 ELASTOBASE P is a polyester -reinforced, SBS modified bitumen base sheet. 4.2 Self-Adherino Underlavments: 4.2.1 POLYSTICK MTS is a rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced with polyolefinic film surface. 4.2.2 POLYSTICK IR-Xe is a rubberized asphalt waterproofing membrane, glass fiber reinforced, with a sand surface. 4.2.3 POLYSTICK TU is a rubberized asphalt waterproofing membrane, glass fiber reinforced, with a granular surface. 4.2.4 POLYSTICK TU Pius is a rubberized asphalt waterproofing membrane, glass fiber reinforced, with a high strength polyester fabric surface. 4.2.5 POLYSTICK TU P is a rubberized asphalt waterproofing membrane, glass-fiber/polyester reinforced, with a granular surface. 4.2.6 POLYFLEX SAP, PoLYFLEX SAP FR, MULE -HIDE SA-APP CAP SHEET AND MULE -HIDE SA-APP CAP SHEET (FR) are a polyester reinforced, APP modified bitumen cap sheets. 4.2.7 DUAL PROT" is a dual -layer rubberized asphalt waterproofing membranes, fiberglass reinforced, with a high strength polyester fabric surface. 4.2.8 TILE PROTM is a dual -layer rubberized asphalt waterproofing membranes, fiberglass reinforced, with a high strength polyester fabric surface. 4.3 Mechanically Fastened and/or Bonded Underlayments: 4.3.1 ELASTOFLEX S6G AND ELASTOFLEX S6G FR are polyester reinforced, SBS modified bitumen cap sheets. 4.3.2 POLYFLEx G AND POLYFLEx G FR are polyester reinforced, APP modified bitumen cap sheets. S. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ. 5.2 Fire Classification is not part of this Laboratory Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.3 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the AHJ for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.4 Allowable roof covers applied atop the underlayments are as follows: Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R5 Certificate of Authorization #9503 FL5259-R10 Revision 5: 06/25/2010 Page 3of9 r r r' ERD TRINITY Table 1: Roof Cover Options Underlayment Asphalt Shingles Nail -On Tile Foam -On Tile Metal Wood Shakes & Shingles Slate Elastobase Yes Yes No Yes Yes Yes Elastobase P Yes Yes No Yes Yes Yes Polystick MTS Yes (Batten Yes only) No Yes Yes Yes Polystick IR-Xe Yes No No No Yes Yes Polystick TU Yes Yes Yes No Yes Yes Polystick TU P Yes Yes Yes No Yes Yes Polystick TU Plus Yes Yes Yes Yes Yes Yes Dual Pro Yes Yes No Yes Yes Yes Tile Pro Yes Yes No Yes Yes Yes Elastoflex S6G or S6G FR Yes Yes Yes No Yes Yes Polyflex G or G FR Yes Yes Yes No Yes Yes Polyflex SAP or SAP FR Yes Yes Yes No Yes Yes Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Yes Yes Yes No Yes Yes 5.4.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives unless tensile adhesion / long term aging data from an accredited testing laboratory is provided. ➢ Polyfoam PolyPro AH160: Polystick TU, Polystick TU P, Polystick TU Plus, Elastoflex S6G, Elastoflex S6G FR, Polyflex G, Polyflex G FR, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR). ➢ Dow TileBond: Polystick TU P or Polyflex SAP 5.4.1.1 The maximum design pressure for direct -bond Polystick self -adhering applications to plywood or primed plywood is -135 psf. This is pertinent for foam -on tile systems only, where the bonded underlayment forms part of the load -path. 5.4.2 For nail -on tile systems over Polystick MTS, battens are required for both loading / staging of the tile and tile installation; direct -to -deck nail -on tile applications are not permissible with Polystick MTS. 5.4.3 For mechanically attached metal and nail -on tile, an underlayment system consisting of Polystick MTS followed by Polystick MTS, TU, TU P or TU Plus or Polystick SAP is permissible. 5.5 Allowable substrates are noted below: 5.5.1 Direct -Bond to Deck: ➢ Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: ASTM D41 primed structural concrete; OSB; Southern Yellow Pine; New untreated plywood; existing plywood primed as needed with ASTM D41 primer; or Huber Engineered Woods "ZIP System" Panels (designed and installed to meet wind loads for project). ➢ Dual Pro or Tile Pro self -adhered to: New untreated plywood; or existing plywood primed as needed with ASTM D41 primer. ➢ Elastoflex S6G or S6G FR in hot asphalt to: ASTM D41 primed structural concrete. ➢ Polyflex G or G FR torch -applied to: ASTM D41 primed structural concrete. Exterior Research and Design, LLC. Evaluation Report P12060.02.09-115 Certificate of Authorization #9503 FL5259-R10 Revision 5: 06/25/2010 Page 4 of 9 i ERD Ti�INITY 5.5.1.1 The maximum design pressure for direct -bond Polystick self -adhering applications to plywood or primed plywood is -135 psf. This is pertinent for foam -on tile systems only, where the bonded underlayment forms part of the load -path. For other substrates, consult Polyglass USA, Inc. 5.5.2 Bond -to -Insulation: ➢ Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: ASTM C1289, Type II, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; DensDeck DuraGuard; DensDeck Prime; or SECUROCK Gypsum -Fiber Roof Board. ➢ Elastoflex S6G or S6G FR in hot asphalt to: DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board. ➢ Polyflex G or G FR torch -applied to: ASTM D41 primed structural concrete; DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile systems, insulation shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4470, Appendix K or TAS 114, Appendix J. 5.5.3 Bond to Mechanically Attached Base Layer: ➢ Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or Tile Pro self -adhered to: ASTM D226, Type I or II felt; Elastobase; Elastobase P or Mule -Hide Nail Base. ➢ Elastoflex S6G or S6G FR in hot asphalt to: ASTM D226, Type I or. II .felt; Elastobase; Elastobase P or Mule -Hide Nail Base. ➢ Polyflex G or G FR torch -applied to: Elastobase; Elastobase P or Mule -Hide Nail Base. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam -on tile systems, base layer shall be attached per minimum requirements of FRSA/TRI 07320/8-05 or RAS 120. 5.6 Exposure Limitations: 5.6.1 Elastobase, Elastobase P, Dual Pro or Tile Pro shall not be left exposed for longer than 30- days after installation. 5.6.2 Polystick IR-Xe shall not be left exposed for longer than 90-days after installation. 5.6.3 Polystick MTS, TU, TU P or TU Plus shall not be left exposed for longer than 180-days after installation. 5.6.4 Polyflex SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure limitation, unless the prepared roof covering is to be adhesive -set tile, in which case the maximum exposure is 30 days. 5.6.5 Elastoflex S6G or S6G FR or Polyflex G or G FR does not have an exposure limitation, unless the prepared roof covering is to be adhesive -set tile, in which case the maximum exposure is 180 days. Exterior Research and Design, LLC. Evaluation Report P12060.02.09-115 Certificate of Authorization #9503 FL5259-R10 Revision 5: 06/25/2010 Page 5 of 9 TRINITY ERD 5.7 For tile roof installations governed by the FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, use is limited to the following: Table 2: Tile System Options for Roof Underlayments per FRSA/TRI 07320/8-05 System Underlay Option Section Reference Product(s) 1 3.02A Modified Cap Sheet Elastoflex S6G or S6G FR; Polyflex G or G FR 2 3,02B No. 30 / Modified Cap Elastobase; Elastobase P / Elastoflex S6G or S6G FR or Sheet Polyflex G or G FR System One: 3 3.02C No. 30 / Modified Cap Sheet Elastobase; Elastobase P / Elastoflex S6G or S6G FR Mechanically Fastened Tile, 4 3.02D No. 30 Elastobase; Elastobase P Self -Adhered Polystick MTS (batten only); TU; TU P; TU Plus; Polyflex Unsealed or Sealed Underlayment 5 3.02E Underlayment SAP or SAP FR; Mule -Hide SA-APP Cap Sheet or SA-APP System Cap Sheet (FR); Dual Pro; Tile Pro Elastobase; Elastobase P; Mule -Hide Nail Base / Polystick 6 3.02F No. 30 / Self -Adhered MTS (batten only); TU; TU P; TU Plus; Polyflex SAP or Underlayment SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR); Dual Pro; Tile Pro 1 3.02A Modified Cap Sheet Elastoflex S6G or S6G FR; Polyflex G or G FR No. 30 / Modified Cap Elastobase; Elastobase P / Elastoflex 56G or S6G FR or 2 3.02B Sheet Polyflex G or G FR System Two: 3 3.02C No. 30 / Modified Cap Elastobase; Elastobase P / Elastoflex S6G or S6G FR Mechanically Sheet Self -Adhered Polystick TU; TU P; TU Plus; Polyflex SAP or SAP FR; Fastened Tile, Sealed 4 3.02D men Underlayment y Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR); Underlayment Dual Pro; Tile Pro System Elastobase; Elastobase P; Mule -Hide Nail Base /Polystick 5 3.02E No. 30 / Self -Adhered TU; TU P; TU Plus; Polyflex SAP or SAP FR, Mule -Hide SA- Underlayment APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro; Tile Pro 1 3.02A Modified Cap Sheet Elastoflex S6G or S6G FR; Polyflex G or G FR "A": 2 3.02B No. 30 / Modified Cap Elastobase; Elastobase P / Elastoflex S6G or S6G FR or System Four Sheet Polyflex G or G FR Adhesive -Set Tile, Unsealed or Sealed 4 3.02D Self -Adhered Polystick TU; TU P; TU Plus; Polyflex SAP or SAP FR; Underlayment Underlayment Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) System No. 30 / Self -Adhered Elastobase; Elastobase P; Mule -Hide Nail Base / Polystick 5 3.02E Underlayment TU; TU P; TU Plus; Polyflex SAP or SAP FR, Mule -Hide SA- APP Cap Sheet or SA-APP Cap Sheet (FR) 1 3.02A No. 30 / Modified Cap Elastobase; Elastobase P / Elastoflex S6G or S6G FR or System Four "B": Sheet Polyflex G or G FR Adhesive -Set Tile, 3 3.OZC Self -Adhered Polystick TU; TU P; TU Plus; Polyflex SAP or SAP FR; Sealed Underlayment Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Underlayment No. 30 / Self -Adhered Elastobase; Elastobase P; Mule -Hide Nail Base / Polystick System 4 3.02D Underlayment TU; TU P; TU Plus; Polyflex SAP or SAP FR, Mule -Hide SA- APP Cap Sheet or SA-APP Cap Sheet (FR) 6. INSTALLATION: 6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). Exterior Research and Design, LLC. Certifcate of Authorization #9503 Evaluation Report P12060.02.09-R5 FL5259-R10 Revision 5: 06/25/2010 Page 6 of 9 I i TRINITY ERD 6.3 Elastobase, Elastobase P or Mule -Hide Nail Base: 6.3.1 Shall be installed in compliance with the requirements for ASTM D226, Type II underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.3.2 For use in non -tile applications: 6.3.2.1 Reference is made to the current edition of the NRCA Steep -slope Roofing Manual and ARMA recommendations for installing shingle underlayments and flashings 6.3.2.2 Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), Dual Pro or Tile Pro, self -adhered, Elastoflex S6G or S6G FR in hot asphalt or Polyflex G or G FR, torch applied. 6.3.3 For use in tile applications, reference is made to Polyglass published installation instructions in conjunction with FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein. 6.4 Polystick MTS, IR-Xe, TU, TU P or TU Plus, Polyflex SAP or SAP FR, Mule -Hide SA- APP Cap Sheet or SA-APP Cap Sheet (FR), Dual Pro or Tile Pro: 6.4.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.4.2 For non -tile applications: 6.4.2.1 All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) should be back -nailed in selvage edge seam as per Polyglass / Mule -Hide Back Nailing Guide. Nails shall be corrosion resistant, 11 gauge ring -shank type with a minimum 1-inch diameter metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.c. "Polystick TU Plus should be back -nailed using the above noted fasteners and spacing, in area marked "nail area, area para clavar" on the face of membrane. The head lap membrane is to cover the area being back -nailed 6.4.2.2 All seal lap seams (selvage laps) must be firmly rolled with a minimum 28 lb. hand roller to ensure full contact and adhesion. For Dual Pro and Tile Pro, align the edge of the top sheet to the end of the glue pattern (the sheet will overlap the fabric). View of Ovelap Seam of Dual Pro and Tile Pro Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R5 Certificate of Authorization #9503 FL5259-R10 Revision 5: 06/25/2010 Page 7of9 t' TRINITY . ERD 6.4.2.3 All over -fabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Electrometric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic, applied in between the application of the lap. 6.4.2.4 Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details 6.4.2.5 Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Mule -Hide 241. Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic to the area in need of repair, followed by a minimum 6 x 6 inch patch of the Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be installed in a water shedding manner. 6.4.2.6 All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied for the field membrane. Hand rollers are acceptable for rolling of patches, laps (min. 28 lb roller) or small areas of the roof that are not accessible to a large roller or broom. 6.4.3 For tile applications (not allowed for Polystick IR-Xe): 6.4.3.1 Reference is made to Section 6.4.2 herein in conjunction with FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein, using the instructions noted above as a guideline. 6.4.3.2 For nail -on tile systems over Polystick MTS, battens are required for both loading / staging of the tile and tile installation; direct -to -deck nail -on tile applications are not permissible with Polystick MTS. 6.5 Elastoflex S6G or S6G FR: 6.5.1 Elastoflex S6G or S6G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications, reference is made FRSA/TRI 07320/8- 05 Installation Manual, Fourth Edition, and Table 2 herein. 6.5.2 Elastoflex S6G or S6G FR shall be fully asphalt -applied to the substrates noted in Section 5.5. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, and off set end -laps minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge. 6.6 Polyflex G or G FR: 6.6.1 Polyflex G or G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications, reference is made FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein. 6.6.2 Polyflex G or G FR shall be fully asphalt -applied to the substrates noted in Section 5.5. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, and off set end -laps minimum 3 feet from course to course. Side and end laps shall be fully heat -welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge. Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R5 Certificate of Authorization #9503 FL5259-R10 Revision 5: 06/25/2010 Page 8 of 9 J 7 6.7 Tile Staging: ` TRINITY--; ERD 6.7.1 A maximum of 6 tiles per stack are allowed when loading the directly onto the underlayments. Refer to the Polyglass Tile Loading Guidelines. 6.7.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRI 07320/8- 05 must be used on all roof slopes of 7:12 or greater. For roof slopes in excess of 61/4:12, precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. 6.7.3 For nail -on tile systems over Polystick MTS, battens are required for both loading / staging of the tile and tile installation; direct -to -deck nail -on tile applications are not permissible with Polystick MTS. 6.7.4 The minimum cure time after installation of self -adhering membranes and before loading of roofing tiles is forty-eight (48) hours. 7. LABELING: Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. S. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. Rule 9B-72 QA requirements 10. QUALITY ASSURANCE ENTITY: Underwriters Laboratories — QUA1743 (847)664-3281 - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R5 Certificate of Authorization #9503 FL5259-R10 Revision 5: 06/25/2010 Page 9 of 9