Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSDATE. �b —o PERMIT NUMBER:' I y I -gT SCANNED BY, St. Lucie County PLANNING & DEVELOPMENT SERVICES DEPARTMENT BUILDING & CODE REGULATIONS DIVISION 2300 Virginia Avenue Fort Pierce, FL 34982 (772) 462-1553 APPLICATION FOR REPLACEMENT OF WINDOWS, SKYLIGHTS, DOORS & OVERHEAD GARAGE DOORS 1. LOCATION/SITE ADDRESS: 1=2 S. C an l�r - — 5 �)4- Serr-Ea R 2. PARCEL ID NUMBER: 2-,5-DZ -7Cd W? ':; d 00Le 3. DESCRIPTION OF PROJECT OR WORK ACTIVITY: AAA Orpv Aed Jwf.S 4. TYPE OF STRUCTURE: SIR MOBILE HOME OTHER i 5. OWNERS INFORMATION 6. CONTRACTOR'S INFORMATIOON Name: V �V 1 �A- - FL Reg/Cert ,yyy� ( Coun �� -n�� Address: 1(�,nt�Kl�(/ Ja . I�pC, IA tyCert #- 9. CityState:���� _ Business Name: C/,a Ul��^ Zip: Phone: Phone Number - Windows, Swing Doors, Skylights, Fixed Glass Opening Design Pressure A.S.C.E - 7 Design Pressure Product Manufacture Model # Method of Attachment # Florida Product Approval # 120 mph 1130 mph 1140 mph Windows & Skylights Exposure Be- -'7- G� Exposure C Overhead Garage Doors < 30' - F.B.C. Table 1609.6 (1) + 1609.6 (2) B- Size C- Size 7. VALUE OF CONSTRUCTION: $ r FEES DUE: 9 ---) O L J RECEIPT: 13 et' a) - OWNER'S AFFiDAvrr: I certify that all of the information contained in this application is correct and that all work will be done in compliance with all a licable laws regulating constructio4and zoning. FQUALIFIBR70WNER. PRINT QUALIFIERS/OWNERS NAME G O;. T r STATE OF FLORIDA, COUNTY OF l L- �� vv'\ /�� HAS PRODUC ACKNOWLEDGED BEFORE ME THIS AS DENTOIFICATION. 2 BYM Jr fM� f "V HO IS PERS( NALt�LY TOWN TO ME OR WHO siGNATUR'E dF ROTARY TYPE OR PRINT NAME OF NOTARY TITLE: NOTARY PUBLIC COMMISSjq j' k% iIBER BNNF l I: o; �-�: • r : •*: MY COMMISSIO # 6 �F NOTICE TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF •. " MEJWplAt:4 y'1' I YOUR PAYING w.�� Bonded Tbro Notary Public Underwriters x CIVIL - STRUCTURAL - MARINE ENGINEERING, LLC SLIDER DOOR REPLACEMENT SUBMITTAL, BOOK FOR MIRAMAR CONDOS ST. LUCIE COUNT::} PROJECT. EXTERIOR SLIDER DOOR REPLACEMENT FOR UNIT #504 0 SHEA RESIDENCE CODE: FLORIDA BUILDING CODE (FBC 2007) WITH 2O09 SUPPLEMENTS AND ASCE 7-05 DESIGN PARAMETERS: WL=140 'VP H EXP. "C"; 1 = 1.0 CSM ENGINEERING 189 S.W. MONTEREY ROAD STUART',. FL 34994 772-220-4601 JLftY AN PERKINS 04TE: FLORIDA REGISTERED PROFESSIONAL ENGINEER #62332 Building Permit # Planning & Development Services Department Building & Regulations Division Product Review Affidavit 'Owners Name (K CU'XI Cp Applicant: i Product Opening Design Pressures, Product Rated Desi n Pressure Manufacturer Model Number Product Approval Number Glass Type Method of Attachment Windows Mullions Fixed Glass Block Glass Skylights i Sliding Glass Doors Swing Type Doors t �--- 53 pw -100 --?o ps - SOO 0 O $ - 0fe %'6 X*.'p4c CcmG4-e Se *, At' K,1 a >c French Doors Garage Doors Hurricane Protection i Roof Ventilation Roofing Material I have reviewed the above eomponents.or cladding and I have approved their use in this structure. These products provide adequate resistance to the wind loads and forces specified by current code provisions. . Name: YcAds9 / j�1/' ,.rl,s Signature: mot, It �'c/ Design Prof: S � - t i'l'e� Cert. No. I � 3 � c�. Date: seal ome4jt REAR. OF BUILDING IS FACING EAST GLASS SLIDER ENTRY DOOR TO BE REPLACED INTERIOR UNITS SIZE: 144" X 80° SLIDER DOOR LOCATIONS TYPICAL EACH FLOOR IMPACT - 5000. SERIES NOA#08-0630.02 ONLY DOORS LISTED IN THE CHART ARE TO BE REMOVED AND REPLACED. WIND PRESSURES SLIDER POSITIVE PRESSURE NEGATIVE PRESSURE FLOOR HT. (FT.) DOOR 53 PSF -53 PSF 100'-0" GENERAL AND STRUCTURAL NOTES: 1.'ALL CONSTRUCTION SHALL BE DONE INACCORDANCE WITH THE 2007 FLORIDA BUILDING CODE, WITH 2O09 SUPPLEMENTS. 2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS ON SITE BEFORE CONSTRUCTION HAS BEGUN. ALL OBSERVED DISCREPANCIES 'HALL BE REPORTED IMMEDIATELY TO THE ENGINEER. 3. DOORS TO ATTACH TO EXISTING STRUCTURE WITH 1./4.0 CONCRETE SCREWS WITH MIN. 1-1/2"'EMBEDMENT PER NOA#08-0213-1 & NOA#08-0630.02 CHART OF UNITS TO REPLACE SLIDER DOORS: UNIT # 3000 SERIES 5000 SERIES IMPACT X NON —IMPACT 102 105 X 305 x 504 X 704 i 802 X 805 PROJECF. ' MIRAMAR SLIDER DOOR REPLACEMENT 10,000 S. OCEAN DR. JENSEN BEACH, FLORIDA 772-229-1330 CES00 er: M TNAW1 er, 00 CIEOIEO If/: JP ROT GATE: II-od-1011 R\9JOER DOOR UFAW WIER WAN SCALE: AS SIM MOIEC 11 . THE ENONEER KREDf ERPRESgT RESERVES HIS C04xOR UR COPrWwr ANO ONEa FROPfarc WGMS. 11ESf PTN15 /NO EaARfgS AaE NOT TO RE RTPR000LE0, tHANCEO, COPED, DR ASSR@EO 10 ANY T% PARrr N ANf TON OR w ER MISOEVER WTMW RRST OarNNN6 THE EMUS WRITTEN PERWSMN AND CORSENT Of CSL DIVICERS. LLG I" DOW�ENi. THE IDUS AND OESVIS NCORP 0TEO HERON, AS AN INSiMIUENi Q PROFE59D11AL SERVKE. 6 THE PROPERR' ai CSY ENONEERS, LLC AND IS HOT TO BE USED, N WI06E OR N PARE FOR AW OTHER PROTECT WIHOIT TIE WRITER ANTHOI67AMN Of CSR ENONEERNG. LLG CSM EMTIEERS, QC WPRRGHI i2010 ALL OTIENM SHINE 6E VERfEO N TNC REID BY THE CONTRACTM THE CWINACipt 6 RESPONSIBLE fOR TIE coam Wryl GE' AlL DNFx5gx1 AE SCALES NDTEATED PERIM TO 24VV PLOTS CIVIL - STRUCTURAL MARINE ENGINEERINt3, LLC CSM ENGINEERING, LLD 189 SW MONTEREY RD STUART. FLORIDA 34994 PH: 772.22b , 4601 F%:772.220,4603 YASW.CSMENGINEERS.COM CDTRRCATE T Al31 MMPON: M6263 11A UDY ANN OERKINS DATE ROWW RED6IEIED PROFESS K ENGEEER Eq. 62331 SHEET mE: SLIDER DOOR NOTES & DETAILS SEEr �: Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue - Fort Pierce, FL 34982 772462-1553 Design Certification for Wind Load Compliance This Certification must be completed by the project design architect or engineer. This Certification must be submitted in duplicate with all applications for building permits involving the construction of new residence (single or multi- family), residential addition, any accessory structure requiring a building permit, and any nonresidential structure. This Certification shall not apply to interior renovations (provided that no exterior structural walls, columns or other components are being affected) and certain other minor building permits. For further assistance, please contact the Building Inspection Office at (772)462-1553 Pro)ecri�Iame._-- ottr Street Address (Qpop SD a--wigr)r-.J Permit Number J -e_KS Occupancy Type FL I Construction Type Certification Statement: I certify that, to the best of my knowledge and belief, these plans and specifications have been designed to comply with the applicable structural portion of the Building Codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to .the wind loads and forces specified by current code provisions. Design Parameters and Assumptions Used: (Please check or complete the appropriate box.) 1 Florida Building Code 20P 7_Edition with 20L�l I Supplements and ASCE 7 " 015- 2. Building Design is: Enclosed: _ Partially Enclosed: Open Building: 3. Mean Roof Height: 100 'n+ Roof Pitch: F [ #-+ Internal Pressure Coefficient: 4. Width of End Zone: f— Wind Speed: ` Y® (3 sec. gust) 5. Building Classification Table 1-1. ASCE 7 -7L FBC Table 1604.5 6. Wind Exposure Classification: C. Adjustment Factor for Exposure & Height: Ia,& 7. Components & Cladding Wind Pressure on Roof Zone 1 ` 2 3. PSF 8. Components & Cladding Wind Pressure on Wall Zone 4 +l n5 PSF 9. Components & Cladding wind Pressure on Overhead Garage Door PSF 10. Loads: Floor PSF Roof/dead PSF Roof/live PSF 11. Shear Walls Considered for Structure? Yes No (if No, attach explanation) 12. Continuous Load Path.provided? Yes No (if No, attach explanation). 1d}'fit �' eCP 13. Are Component and Cladding Details Provided? Yes )4 No. (if No, attach explanation) S�tr S 14. Minimum Soil Bearing Pressure: 'Presumptive: By Test: PSF As witnessed by my seal, I hereby certify that the information included with this certification is true and correct, to the best of m``y�� knowledge and belief. Name: �� "1 ��'` k C r `g Cert # Design Firm • C SDI' ` G 11 1 el P_ e4 ( Date• SLCCDV Form # 020-00 SEA Revised 2/27/09 (CL) Revised 6/11/2010 (IS) j 11 �� COl1N1'Y BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION MIAMI—DADE COUNTY, FLORIDA METRO—DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1107 MIAMI, FLORIDA 33130-1563 (305) 3754902 FAX (305) 372-6339 NOTICE OF ACCEPTANCE (NOA) www.miamidade.Govlbuildingcode Southeastern Door. Company 1505 Commerce Lane P. O. Box 794 Jupiter, FL 33458 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami -Dade County and other -areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expirationdate stated below. The Miami -Dade County Product Control Division (In .Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes: If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of'such product or material within their jurisdiction. BORA reserves the right to revoke this. acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series "Atlas Plus Series 5000" Aluminum Sliding Glass Door - S.M.I. APPROVAL DOCUMENT: Drawing No. 09 220RI; titled "Atlas Plus Series 5000 Aluminum Sliding Glass Door Small Missile Impact", sheets 1 through 13 of 13, prepared by EngCo. Inc., dated 02/05/10, signed and sealed by Pedro De Figueiredo, P. E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Division. MISSILE IMPACT RATING: Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed; then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by, the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises and renews NOA No. 03-0527.08 and consists of this page I and evidence pages. E-1, E-2 and E-3, as well as approval document mentioned above. The submitted documentation was reviewed by Jaime D. Gascon, P. E. NOA No. 08-0630.02 MIAMI-DADE COUNTY .J r Z a I Io Expiration Date: June 26,2013 Approval Date: March 03, 2010 �' -Page 1 Southeastern Door Company NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer's die drawings and sections. 2. Drawing No. 09-226R1, titled "Atlas Plus Series 5000 Aluminum Sliding Glass Door Small Missile Impact", sheets 1 through 13 of 13, prepared by EngCo. Inc., dated 02/05/10, signed and sealed by Pedro De Figueiredo, P. E. B. TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94' 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Small Missile Impact Test per FBC, TAS 201-94 5) Large Missile Impact Test per FBC, TAS 201-94 6) Cyclic Wind Pressure Loading per FBC, TAS 203-94 _ 7) Forced Entry Test, per FBC 2411 3.2.1 and TAS 202-94 along with marked up drawings and installation diagram of a Aluminum Sliding Glass Door, prepared by Hurricane Test Laboratory, Inc., Test Report No. HTL 0151480148, dated 02/12/09, signed and sealed by Vinu J. Abraham, P. E. 2. Test reports on: 1) Uniform. Static Air Pressure Test, Loading per FBC, TAS 202-94 2) Small Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked —up drawings and installation diagram of a Aluminum Sliding Glass Door, prepared by Hurricane Test Laboratory, Inc., Test Report No. HTL 0151490549, dated 10/19/09, signed and sealed by Vinu J. Abraham, P. E. 3. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94 2) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked —up drawings and installation diagram of a Aluminum Sliding Glass Door, .prepared by Hurricane Test Laboratory., Inc., Test Report No. HTL 0151-0909-01, dated 09/07/01, signed and sealed by Vinu J. Abraham, P. E. (Submitted under previous NOA No. 03-0527.08) 4. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Teat, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading. per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411 3.2.1 and TAS 202-94 along with marked —up drawings and installation diagram of a Aluminum Sliding -Glass . Door, prepared by Hurricane Test Laboratory, Inc., Test Report No. HTL 0151-1105-01, dated 12/12/01, signed and sealed by Vinu J. Abraham, P. E. (Submitted under previous NOA No. 03-052;7.08) Jaime D. Gascon, P. E. Chief, Product Control Division NOA No. 08-0630.02 Expiration Date: June 26, 2013 Approval Date: March 03, 2010 E -1 Southeastern Door Company NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED B. TESTS (CONTINUED) 5. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure. Loading per FBC, TAS 203-94 along with marked —up drawings and installation diagram of a Aluminum Sliding Glass Door, prepared by Hurricane Test Laboratory, Inc., Test Report No. HTL 0151-1209-02, dated 12/12/02, signed and sealed by Vinu J. Abraham, P. E. (Submitted under previous NOA No. 03-0527.08) 6. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 2) Small Missile Impact Test per FBC, TAS 201-94 along with marked -up drawings.and installation diagram of a Aluminum Sliding Glass Door, prepared by Hurricane Test Laboratory, Inc., Test Report No. HTL 0151-0117-03, dated 01/14/03, signed and sealed by Vinu J. Abraham, P. E. (Submitted under previous NOA No. 03-0527.08) . C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 2007, prepared by EngCo. Inc., dated October 30, 2009 and February 05, 2010, signed and sealed by Pedro De Figueiredo, P. E. Complies with ASTM E1300-04 D. QUALITY ASSURANCE 1. Miami —Dade Building Code Compliance Office (BCCO). E. MATERIAL CERTIFICATIONS I. Notice of Acceptance No. 09-0312.03 issued to E.I. DuPont DeNemours. & Co., Inc. for their "DuPont Sentry Glass® Interlayer" dated 05/13/09, expiring on 01/14/12. 2. Notice of Acceptance No. 09-0312.02 issued to E.I. DuPont DeNemours & Co., Inc. for their "DuPont Butacite®.PVB, Interlayer" dated 05/13/09, expiring on 12/11/1.0. F. STATEMENTS 1. Statement letter of conformance and no financial interest, dated October 30, 2009, signed and sealed by Pedro De Figueiredo, P. E. 2. Laboratory compliance letter for Test Reports No.'s HTL 0151— 0801— 08 and HTL 0151-0905-09, issued by Hurricane Test Laboratory, Inc., dated February 12 and October 19, 2009, signed and sealed by Vinu J. Abraham, P. E. !��4 �-- I Jaime D. Gascon, P. . Chief, Product Control Division NOA No. 08-0630.02 Expiration Date: June 26, 2013 Approval Date: March 03, 2010 E -2 Southeastern Door Company NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED F. STATEMENTS (CONTINUED) 3. Laboratory compliance letter for Test Reports No.'s HTL 0151— 0909 — 01, HTL 0151-1105-01, HTL 0151-1209-02 and HTL 0151-0117-03, issued by Hurricane Test1aboratory, Inc., dated 09/07/01, 12/12/01, 12/12/02 and 01/14/03, signed and sealed by Vinu Abraham, P. E. (Submitted under previous NOA No. 03-0527.08) G. OTHERS 1. Notice of Acceptance No. 03-0527.08, issued to'Southeastern Door Company their Series "Atlas Plus Aluminum Sliding Glass Door — SMI", approved on 06/26/03 and expiring on 06/26/08. " Jaime D. Gascon, PA. Chief, Product Control Division NOA No. 08-0630.02 Expiration Date: June 26, 2013 Approval Date: March 03, 2010 E -3 GENERAL NOTES: FLORIDA BUILDING CODE 2007 1- CODE: THIS PRODUCT HAS BEEN TESTED AND DESIGNED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE 2007 INCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ). 2- DEFINITION, THIS PRODUCT IS AN ALUMINUM SLIDING GLASS DOOR DESIGNED, CONSTRUCTED AND TESTED PROVIDING PROTECTION FROM HURRICANE FORCE WINDS AND WIND BORNE DEBRIS (SMALL MISSILE) WITHIN THE ALLOWABLE DESIGNED PRESSURES AND LIMITATIONS STATED IN THIS APPROVAL. INSTALLATION OF HURRICANE PROTECTION DEVICES ARE REQUIRED FOR INSTALLATIONS BELOW 30' ELEVATION. 3- POSTINGS 'SOUTHEASTERN DOOR COMPANY JUPITER - FLORIDA DADE COUNTY PRODUCT CONTROL APPROVED' 4- DESIGN`L:OADS+' THE DESIGNED LOADS MUST BE CALCULATED BY.A'PROFESSIONAL ARCHITECT OR ENGINEER FOR EACH SPECIFIC PROJECT, THE CALCULATED DESIGNED PRESSURE MUST NOT EXCEED THE PRODUCT DESIGNED RATING PRESSURE. 5- MATERIAL, ALL ALUMINUM PARTS TO BE 6063-T6 ALLOY OR AS NOTED AND GLAZING TO BE LAMINATED IMPACT GLASS AS SPECIFIED ON THIS APPROVAL. 6- FASTENERS, ASSEMBLY SCREWS AND ANCHORS SHALL BE AS SPECIFIED IN THE CURRENT SET OF DRAWINGS, INSTALLATION AND LOADS AS PER THIS APPROVAL. ANCHOR SPACING AND LOADS MUST NOT EXCEED THE MAXIMUM LIMITS SPECIFIED BY THIS APPROVAL, 7- USE- IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR, ARCHITECT OR ENGINEER OF RECORD TO VERIFY THE FOLLOWING, 7.1- THE STABILITY OF THE STRUCTURE WHERE THE PRODUCT IS TO BE ATTACHED INSURING PROPER ANCHORAGE. 7.2- THE SITE SPECIFIC PROJECT CRITERIA, SUCH AS BUT NOT LIMITED TO, LOCAL CODE REQUIREMENTS, DESIGNED PRESSURES ETC. 7.3- THAT THIS APPROVAL IS ADEQUATE TO THE SPECIFIC PROJECT. 8- 33 1/3% INCREASE IN ALLOWABLE LOADS HAVE NOT BEEN USED IN THE DESIGN OF THE ANCHORS FOR THIS PRODUCT APPROVAL, HOWEVER, WOOD SCREWS WITH 1.6 INCREASE FOR WIND LOAD DURATION HAVE BEEN USED, 9- DISSIMILAR MATERIALS, MATERIALS, INCLUDING BUT NOT LIMITED TO STEEL, THAT COME IN CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF 2007 FLORIDA BUILDING CODE. DOOR ELEVATIONS WITH OPERABLE AND FIXED MODULES CONFIGURATIONS 5 OR MORE MODULES -1 MODULE I--- 0_0 milli 11 --I MODULE I-- 4 MODULES 0 X X 0 --� MODULE �- 3 MODULES --I MODULE I- 2 MODULES 0 X --� MODULE I-- 0 x x 0 0 x x x x MODULE --� MODULE MODULE �- 0 X X X x O X X X X X X ---{ MODULE MODULE MODULE r-- DOOR CAN BE CONFIGURED WITH AS MANY MODULES AS THE TWO, THREE, FOUR OR FIVE TRACK SYSTEM CAN FIT DESIGN RATINGS: SHEET TABLE DESCRIPTION 1 RATING FOR 4 OR 3 DOOR MODULES WITH REINFORCEMENT 2 1 RATING FOR 2 DOOR MODULES WITH REINFORCEMENT lA RATING FOR MORE THAN 4 DOOR MODULES WITH REINFORCEMENT 2 RATING FOR 4 3 OR 2 DOOR MODULES WITHOUT REINFORCEMENT B 3 RATING FOR ANCHORAGE INTO 2 TRACK 9 4 RATING FOR ANCHORAGE INTO 3, 4 & 5 TRACKS NOTES. 1- DESIGN RATING WILL BE THE LOWEST PRESSURE FROM APPLICABLE TABLES 2- PLEASE REFER TO SHEET 6 FOR FURTHER POSITIVE PRESSURE LIMITATION DUE TO THRESHOLD HEIGHT. TABLE OF CONTENTS: SHEET DESCRIPTION SHEET DESCRIPTION 1 GENERAL NOTES, TYPICAL ELEVATIONS 8 FRAMING ANCHORAGE RATING AND SCHEDULE 2 DESIGN RATING TABLES 1, IA AND 2 9 FRAMING ANCHORAGE RATING AND SCHEDULE 3 SECTION DETAILS 10 DOOR FRAMING COMPONENTS. 4 SECTION DETAILS & GLAZING DETAILS 11 DOOR SASH COMPONENTS AND BILL OF MATERIALS 5 FRAMING ANCHORAGE DETAILS 12 DOOR HARDWARE 6 FRAMING ANCHORAGE DETAILS 13 DOOR & FRAMING ASSEMBLY 7 FRAMING ANCHORAGE DETAIS MANUFACTURER: S®E SOUTHEASTERN NenNeWre,a al6npe�! ResivAnt 56Grp CJnsf OO W9 1505 COMMERCE LANE, P.O. BOX 794 JUPITER, FLORIDA 33458 PHONE: (561) 746-5493 FAX: (561) 575-1826 PRODUCT: ATLAS PLUS SERIES 5000 ALUMINUM SLIDING GLASS DOOR SMALL MISSILE IMPACT Engineering: Krtq(C Jnr. CA 811ee'II�N'bty,� 697'IW tURE P OL a ` No. 2609 z-��E..&► ttt 09 DRAFTING, 5i8 PK DRAFTING & MORE MIAMI-DADE BCCO: PRODUCTR&VISED m complying with the Florida Building Code AcceptEd& No ( BY _ MiantlProduct Contort Divbion Date: 02/05/10 Scale: NA Design by: PPMF Drawing Number 09=220R1 SHEET 1 of 13 TABLE 1 2 DOOR MODULES W/ REINFORCEMENT 4 OR 3.00OR MODULES W/ REINFORCEMENT SECTIONS 7 AND 6 # OR DOOR MODULES rni io a. T Po r TUn MODULE WIDTH FRAME HEIGHT PD RATING PD RATING GLASS TYPE (+) (-) (+) I (-) 30 80 90, 0 100. 0 90. 0 100.0 B C 84 90, 0 IGO. 0 90. 0 100.0 -B-C- 96 90, 0 100. 0 90, 0 100. 0 B C 100 90. 0 100. 0 90. 0 100. 0 B C 104 90. 0 97, 6 90. 0 100. 0 B C 108 7TT 7 83. 7 0. 0 0. 0 H C 120 54. 6 54.6 66. 2 66.2 B C 36 80 90, 0 100.0 90. 0 100. 0 B C 84 90. 0 100. 0 90. 0 100.0 B C 96 90. 0 100. 0 B C 100 90, 0 970 1 B C 104 82.6 82.6 90. 0 100, 0 B C 108 70. 7 70. 7 65..7 8 B C 120 T-6 0 46. 0 5. 8 5. 8 B C 42 80 90.0 100. 0 90. 0 100. 0 B C 84 90, 0 100. 0 90. 0 100. 0 B C 96 90. 0 98. 7 90.0 100. 0 B C 100 84. 7 84. 7 90.0 100, 0 B C 104 72. 0 72. 0 B C 108 61. 6 61. 6 74. 7 74. 7 B C 120 40.0 40:0 48.4 48.4 C 48 80 go. 0 too. 0 90. 0 100. 0 B C 84 90. 0 100. 0 90.0 100. 0 B C 88 90,0 98. 2 90.0 100, 0 B C- 92 90, 0 93. 9 90. 0 100. 0 1 -B C 6 90. 0 90. 0 go. 0 100. 0 B C 100 70.0 75.8 70.0 91. 9 C 104 64, 3 64.3 70. 0 78. 0 C 105 60, 6 60. 6 70. 0 73. 4 C 52 80 90. 0 99. 7 90, 0 100, 0 B C 84 90. 0 94, 9 90. 0 100.0 B C 88 90, 0 90. 6 C 97. 5 70. 0 79, 2 C 60 80 70.0 1=6.4 C 82 /U.0 84.3 C 84 70. U I '82. 3 C NOTE- MODULE WIDTH WINCHES FRAME HEIGHT IN INCHES PRESSURE RATING IN PSF 2' THRESHOLD LIMITED TO +50 PSF EXAMPLE�TABLES 1 AND 2 192X96 DX-XO - 4 MODULES MODULE WIDTH= 192/4= 48' // FRAME HEIGHT= 96' DESIGNED PRESSURE +90, -90 PSF W/ REINF. DESIGNED PRESSURE +70, -70 PSF W/OUT REINF. EXAMPLE -TABLES 1 AND 2 96X96 OX - 2 MODULES MODULE WIDTH= 96/2= 48' // FRAME HEIGHT= 96' DESIGNED PRESSURE +90, -100 PSF W/ REINF. DESIGNED PRESSURE +70, -70 PSF W/OUT REINF. EXAMPLE -TABLES 1A 28SX96 OXX-XX❑ - 6 MODULES MODULE WIDTH= 288/6= 48' // FRAME HEIGHT= 96' DESIGNED RATING= ±70 PSF W/ REINF. TYPICAL ELEVATION AND DESIGNED PRESSURES DW - DOOR WIDTH MODULE MODULE MODULE MODULE .MODULE MODULE WIDTH WIDTH WIDTH WIDTH WIDTH --f- WIDTH 1 1 � d � 3 O x k 4 x 5 4 4 7 n Jn � wrR F. ILIZ DM= DW / NUMBER OF MODULE SEE SHEET 3 AND 4 FOR DETAILS TABLE1A MORE THAN 4 DOOR MODULES W/ REINFORCEMENT SECTIONS 7 AND 6 MODULE WIDTH FRAME HEIGHT P➢ RATING (+) (-) GLASS TYPE 30 80 90.0 100.0 B C 84 90.0 100. 0 B C 96 90.0 . 99. 6 B C 100 89. 1 89. I B C 104 75.9 75.9 B C 108 65. 1 65. 1 B C 120 42.5 42.5 B C 36 80 90.0 100.0 B C 90. 0 100. 0 B C 86. 2 86, 2 B C E 75.4 75,4 B C 64. 2 64.2 B C 55.0 55.0 B C 120 35. 8 35. 8 B C 42 80 90.0 96.0 B C 84 90. 0 91. 4 B C 96 76.8 76.8 B C 100 65.9 65.9 B C 104 56.0 56.0 B C. 108 47.9 47.9 B C 48 80 84.0 84.0 B C 84 8010 80.0 R C Be 76.4 76.4 B C 92 73.0 73. 0 B C 96 70. 0 70. 0 B C 54 80 74. 7 74. 7 B C 85 70. 3 70. 3 B C NOTE- MODULE WIDTH IN INCHES FRAME HEIGHT IN INCHES PRESSURE RATING IN PSF 2' THRESHOLD LIMITED TO +50 PSF �F� I LON] LTYPICAL DRAIN PAN SEE SHEET 11 OF 13 TABLE 2 4.3 OR 2 DOOR MODULES W/OUT REINFORCEMENT SECTIONS 4 AND 5 MODULE WIDTH FRAME HEIGHT PD RATING <+) (-)'I GLASS TYPE 30 80 70, 0 70.0 B C 84 70. 0 70.0 H C 96�770.070.0 B C 1070.0 B C 1070.0 B C 1065.1 B C 1242, 5 H C 36 80 70.0 70.0 B C 84 70.0 70.0 B C 96 70.0 70.0 B C 100 70.0 70.0 B C 104 64.2 64.2 B C 108 55. 0 55.0 B C 120 35.8 35.8 B C 42 80 70.0 70.0 B C 84 70.0 70.0 B C 96 70.0 70.0 B C 100 65.9 65.9 1 B C 104 56.0 56.0 B C 110 44.9 44.9 B C 48 80 70.0 70.0 B C 4 70. 0 70,0 B 88 70.0 70.0 B 92 70.0 70.0 B C 96 70.0 70.0 B C 54 80 70.0 70.0 B C 85 70.0 70.0 B C NOTE. MODULE WIDTH IN INCHES FRAME HEIGHT IN INCHES ' PRESSURE RATING IN PSF 2' THRESHOLD LIMITED TO +50 PSF MANUFACTURER: Sf SOUTHEASTERN MenWeeNrers W M yaC ReslsleM SYMp GhssWori 1505 COMMERCE LANE, P.O. Box 7sa JUPITER, FLORIDA 33458 PHONE: (561) 746.5493 FAX: (561) 575-1826 PRODUCT: ATLAS PLUS SERIES 5000 ALUMINUM SLIDING GLASS DOOR SMALL MISSILE IMPACT Engineering: +.Enq(�v Jnr CA 8116 Ipsi�.ww 6971 WdSiuvi6NBBpW No. * c DRAFTING: PK DRAFTING a MORE MIAMI-DADE BCCO: 90DUCrREVISED s wmvlvim with the Florida Date: 02/05/10 Scale: NA Design by: PPMF Drawing Number 09-220R1 SHEET 2of13 0 SEE SHEET 7 FOR HEADER ANCHORING DETAILS MAXIMUM 1/4' SHIM W3 O I I 2, 2A, 2B OR 2C I I HEADER �j j� W3 5 5 I OPTIONAL it j SCREEN DOORwJU 'OUTSIDE INSIDE F 1 = 1 L7 � W x a o W J = A z 8 B 3, 3A, 3B OR 3C 0 i SILL I 1 J ,j '2'THRESHOLD �i LIMITED TO+50PSF II II I N II II 10 i O I I (U SEE SHEET 6 FOR SILL W4 W4 ANCHORING DETAILS MAXIMUM W3 1/4' SHIM LOCK 11 INSIDE w � N J o W 9 OUTSIDE wQ N W3 w� wo w OPTIONAL 12 w¢ w 3A rn 1, IA, LB 0R IC JAMB LOCK STILE OPERABLE MODULE TYPICAL SECTION DETAILS PART 7 WITH 1.75X1.25X.5 DUST PLUG AT EACH ENDS WAS ATTACHED TO PART #6 WITH INSIDE #lOxl-I/2' SS FH SPACED 3' FROM EACH ENDS AND 16,' 6 MAXIMUM ON CENTER. W511 r 13� 9�\ 1 11/-13 #I0XI/2' FH SS 6' FROM END AND 24' OC LOCK JW5 � s---------r--- z 1 IIF--------- I I IC II III �� MEETING STILE ], 'I ICI r(j ^L w/OUT ----- __--- ____ --IL---------� —v — --- REINFORCEMENT OUTSIDE OPTIONAL SCREEN,DOOR W3 INSIDE L9 L11 13J W3 OUTSIDE W1 W2 � OPTIONAL 12 —E 1, 1A, 1B OR 1C q #10-16xl' PHSMS MAXIMUM SPACED AT 16'OC -1/4' SHIM 0 0 JAMB LOCK STILE INTERLOCK STILE FIXED MODULE W/ OUT REINFORCEMENT MANUFACTURER: S 7m SOUTHEASTERN MonWxNrcrsdMpatl Reah}enf SbNg (`i1099 Q'YY9 1505 COMMERCE LANE, P.O. BOX 794 JUPITER, FLORIDA33458 PHONE: (561) 746-5493 FAX: (561) 575.1826 PRODUCT: ATLAS PLUS SERIES 5000 ALUMINUM SLIDING GLASS DOOR SMALL MISSILE IMPACT Engineering: +FngC2ior Jnr. CA 8116 6971 W. Plant !(> ENa �SF ;'PtIO * _ N 52609 DRAFTING. PK DRAFTING & MORE MIAMI-DADE BCCO IRODUCr REVISED s comclvine with Ate Florida ------ Date:02/05/10 OPTIONAL Scale: NA . SCREEN DOOR Design by: PPMF Drawing Number 09-220R1 SHEET 3of13 TYPICAL SECTION DETAILS 20 INSIDE PART 7 WITH 1.75X1.25X.5 DUST PLUG AT EACH ENDS WAS ATTACHED TO PART #6 WITH l3 11 4 #10xl-1/2' SS FH SPACED 3' INSIDE FROM EACH ENDS AND 16' MAXIMUM ON CENTER. us 11 11 9 13 OUTSIDE 13 20 6 11 Cn w ❑ t- 0 4— W5-- __ 20 ' ICi P Zz s7 L Jr -----_#10-16x1' �L` �---- == I4�11L_ L _� SPACED AT 1610C OPTIONAL SCREEN DOOR OUTSIDE OPTIONAL SCREEN DOOR O INTERLOCK STILE W1 REINFORCEMENT O MEETING STILE WI REINFORCEMENT 3A 0 JAMB LOCK STILE INTERLOCK STILE OPERABLE MODULE W/ REINFORCEMENT 13 GLAZING DETAILS MANUFACTURER: S 1/4' HS GLASS /—E. I. DUPDNT INTERLAYER: SOUTHEASTERN 0.060' BUTACITE PVB DR 0. 035° SENTRYGLAS PLUS IONOPLAST 1505 COMMERCE LANE, P.O. /--1/4' HS GLASS BOX794 w JUPITER, FLORIDA 33458 9/16' LAMINATED. IMPACT GLASS N o PHONE: (561) 746-5493 z FAX: (561) 575-1826 13 O PRODUCT: ATLAS PLUS w m SERIES 5000 ALUMINUM l w SAME GLAZING DETAIL 13 SLIDING GLASS DOOR J ❑ APPLICABLE AT THIS SMALL MISSILE IMPACT z SECTION — Engineering: CA 8116 6971 W S Blvd 104 unrlse TYPE B GLASS: Plante 9/16' LAMINATED HS WITH 0. 06' E. I, DUPONT Y^' , ,`;;^"G(/� EN A�JL. BUTACITE_ PVB INTERLAYER .v ENSF'��Fp' TYPE C GLASS- 9/16' LAMINATED HS WITH 0.035' E. I. DUPONT .* 9 SENTRYGLAS.PLUS IONOPLAST INTERLAYER (11) GLAZING ADAPTOR SLID IN PLACE �i f!e°ro.{�ergaeo�Q.'ts• AND SECURED WITH #IOXI 1/2 SS FH —�0�� 5 �G rrr LOCATED 1' FROM EACH END AND SPACED TO BE DRAFTING:"�������� SOEAL�DEWITHNCRL'3ILICOONERS pKDRAFTiNG&MORE LOCKING STILE (13) GLAZING GASKET MIAMI-DADE BCCO: OUTSIDE 1/4' HS GLASS E. I. DUPDNT INTERLAYER: 0. 060' BUTACITE PVB OR RODUCT RBVISED wmplymg with the Florida 0. 035' SENTRYGLAS PLUS IONOPLAST uilding Code _ mphmce No 02 INSIDE 1/4' HS GLASS are bf3 MIN. . LAMINATED IMPACT GLASS y. GLASS miond product Contm BITE Division 3/4' SAME GLAZING DETAIL Date:02105/10 APPLICABLE AT THESE Scale: NA SECTIONS Design by: PPMF INTERLOCK MEETING STILE 13 DI8W1119 Number OUTSIDE 13 OUTSIDE 09-220R1 INsIDE SHEET INSIDE 4 Of 13 FRAMING ANCHORAGE DETAILS MAXIMUM �•�_~ 1/4' SHIM ;wLn LO ¢ . q ..: JAMB TRACK ANCHORED TO a ~ CONCRETE TO MASONRY .. RI W V1,�_ ., A 21 TYPICAL SHEAR CLIP AT EACH ANCHOR LOCATION ANCHOR TYPE A OR B 1/4' TAPCONS BY ITN BUILDEX 0 SPACED AT 16'OC 0 ri 1, IA, 1B OR 1C :0 w z. r, 0j W. a fUw� ,.•:• TYPICAL PERIMETER SEALANT VULKEM 116 POLYURETHANE STRUCTURAL 2X BUCK TO BE DESIGNED BY OTHERS MAXIMUM 1/4' SHIM JAMB TRACK'. ANCHORED TO WOOD 21 TYPICAL SHEAR CLIP AT EACH ANCHOR LOCATION TII ANCHOR TYPE C 0 I/4' TAPCONS BY ITN BUILDER 0 SPACED AT 16'DC 0 r ri �d L �1, 1A, 1B OR 1C TYPICAL PERIMETER SEALANT VULKEM 116 POLYURETHANE 2 TRACK ca 21 w IA 1 -au w W O HK 21 a two W 7 Z OUTSIDE ti mJ METAL STRUCTURE 1/9' MIN. THICKNESS TRACK OPTIONS '! TRAr w MAXIMUM JAMa IHAUK 1/4' SHIM ANCHOREDTO METAL STRUCTURE 21 TYPICAL SHEAR CLIP AT EACH ANCHOR LOCATION ANCHOR TYPE D 1/4-14 SS SHEET METAL SCREWS SPACED AT 16'OC 11IA, 1B OR 1C TYPICAL PERIMETER SEALANT VULKEM 116 POLYURETHANE IC L� UUI31Ut MANUFACTURER: S SOUTHEASTERN Mande[Ivren 0I MPoC Rukfan, G4Uup Gott Gawa 1505 COMMERCE LANE, P.O. BOX 794 JUPITER. FLORIDA 33458 PHONE: (561) 746-5493 FAX: (561) 575-1826 PRODUCT: ATLAS PLUS SERIES 5000 ALUMINUM SLIDING GLASS DOOR SMALL MISSILE IMPACT Engineering: Kitg(Go Inc. CA 8116 697t W. S�9iPr9H1Yj 104 PlanEta OtrS15.1 f F DRAFTING, PK ORAFnINO & MORE MIAMI-DADE BCCO: PRODUCT REVISED ss cemelvina with the Fledda Date: 02/05110 Scale: NA Design by: PPMF Drawing Number 097220R1 SHEET 5of13 I C STAGGERED AT 2 TRACK 3 TRACK OPTIONS 3' FROM EA OTHER .. SEE ILLUSTRATION ON SHEET 7 THRESHOLD LIMITATION, v (SEE SHEET 6 OF 13) N � m OUTSIDE OUTSIDE E. D. E. D. E. D. 1 3 FRAMING ANCHORAGE DETAILS 3A ANCHOR TYPE A 1/4' TAPCONS BY ITW BUILDEX SPACED AS PER TABLE 3 FOR 2 TRACK AND 3 TRACK iu M SPACED AS PER TABLE 4 FOR 3, 4 OR 5 TRACK r 3, 3A, 3B OR 3C E. D. SEE ILLUSTRATION 'Z'&.NOTES ILLUSTRATION'Z" & NOTES OVERHANG MUST BE THRESHOLD GREATER OR! EQUAL TO MAXIMUM PRESSURES (PSF) TYPE FLOUR TO CEILING DIM• CASE 408 l CASE 2 3-1/4' +90 2' 1- +90 +50 l� ~ z CASE 1- DOORS W/ OVERHANG AS PER ILLUSTRATION 'Z' o = [OVERHANG CASE 2- DOORS WITHOUT OVERHANG 0 0� U a w NOTES, = I- THE ABOVE POSITIVE PRESSURES ARE THE MAXIMUM FOR 3-1/4' OR 2' THRESHOLD. 2- USE THE LESSER OF THE ABOVE POSITIVE PRESSURE AND THE POSITIVE PRESSURES FROM TABLES 1, IA OR 2 SILL TRACK ANCHOREDTO CONCRETE 21 21 i.. SILL TRACK TO BE SET ON BEAD OF " '. •.�.�.'.'K .',:r,?,••.e'� POLYURETHANE SEALANT (VULKEM 116) *'•'.::...'..=,- :' OR BASE OF HIGH QUALITY NON -SHRINK ' 3 KSI GROUT 2. 50 �---- EDGE 3.00 DISTANCE SHEAR CLIP PART #21 ARE NOT REQUIRED WHEN TRACK IS SET ON NON -SHRINK 3 KSI GROUT ANCHOR TYPE C 1/4' TAPCONS BY ITW BUILDEX SPACED AS PER TABLE 3 FOR 2 TRACK AND SPACED AS PER TABLE 4 FOR 3, 4 OR 5 TRACK 3, 3A, 3B OR 3C SEE ILLUSTRATION °Z° & NOTES SILL TRACK ANCHORED TO WOOD 21 , r 21 1. 00 3. 00 SILL TRACK TO BE SET ON BEAD OF POLYURETHANE SEALANT (VULKEM 116) WOOD MIN. (G> 55) STRUCTURE BY OTHERS MANUFACTURER: ONE SOUTHEASTERN IUmWatlu,ers N Niptl Reshfenf 5�9 CJau Ooors 1505 COMMERCE LANE, P.O. BOX 794 JUPITER, FLORIDA 33458 PHONE: (561) 746-5493 FAX: (561) 575-1826 PRODUCT: ATLAS PLUS SERIES 5000 ALUMINUM SLIDING GLASS DOOR SMALL MISSILE IMPACT Engineering: q.Eng(Ja .Ja r CA 8116 ........./ 6971 W1/SI�PT@e�lpo„'�_ DRAFTING- PK DRAFTING & MORE MIAMI-DADE BCCO: Division Date: 02/05/10 Scale: NA Design by: PPMF Drawing Number 09-220R1 SHEET 6of13 ANCHOR TYPE C I/4' TAPCONS BY ITW BUILDEX SPACED AS PER TABLE 3 FOR 2 TRACK AND SPACED AS PER TABLE 4 FOR 3, 4 OR 5 TRACK HEADER TRACK ANCHORED TO WOOD 3 DOOR FRAMING -� STRUCTURAL 2X BUCK TO BE DESIGNED BY OTHERS TYPICAL PERIMETER SEALANT VULKEM MAXIMUM 116 POLYURETHANEF777 1/4' SHIM 2, 2A, 2B OR 2C ANCHOR TYPE A 1/4' TAPCONS BY ITW BUILDEX SPACED AS PER TABLE 3 FOR 2 TRACK AND HEADER TRACK SPACED AS PER TABLE 4 FOR 3, 4 OR 5 TRACK ANCHOREDTO CONCRETE • 2, 2. 50 • •"• EDGE •".� 3, 00 EDGE ➢ISTANCE"""' ;'."DISTANCE.`, - TYPICAL PERIMETER SEALANT VULKEM MAXIMUM 116 POLYURETHANEF1 1/4' SHIM - ---2, 2A, 211 OR 2C HEADER TRACK ANCHORED TO METAL STRUCTURE -ANCHOR TYPE D I/4'-14 SS SHEET METAL SCREWS • SPACED AS PER TABLE 3 FOR 2 TRACK AND SPACED AS PER TABLE 4 FOR 3, 4 OR 5 TRACK METAL STRUCTURE TYPICAL PERIMETER 1/8' MIN. THICKNESS SEALANT VULKEM 3.00 116 POLYURETHANE MAXIMUM 1/4' SHIM 2, 2A, 2B OR 2C OUTSII TRACK OPTIONS STAGGERED AT ,r 3' FROM EA OTHER E. ➢. 1� E. D. OUTSIDE 2 TRACK 2 =24 TRACK (RACK MANUFACTURER: ANCHS®E RAGE TOP VIEW LAY —OUT APPLICABLE ONLY SOUTHEASTERN FOR.TWO TRACK SYSTEM 1505 COMMERCE LANE, P.O. BOX 794 JUPITER, FLORIDA 33458 PHONE: (561) 746-5493 FAX: (561) 575-1826 PRODUCT: ATLAS PLUS SERIES 5000 ALUMINUM SLIDING GLASS DOOR SMALL MISSILE IMPACT L Engineering: .3nr. CA 8116 6971 W. Sunrise Blvd.104 Plant jLp 'EN p��.' "EN140 \ FEB * 0901¢ ®eai ; 0�. •Pagtti" 11 =IFS 6uly till PR DRAFTING & MORE MIAMI-DADE BCCO: Date: 02/05110 Scale: NA Design by: PPMF Drawing Number 09-22OR1 SHEET 7of13 FRAMING ANCHORAGE RATING AND SCHEDULE TABLE 3 - (2 TRACK FRAMING) ANCHORAGE CAPACITY IN PSF FUNCTION OF ANCHOR TYPE AND NUMBER OF CLUSTERS ANCHOR TYPE A C D MODULE .WIDTH FRAME HEIGHT 1 2 1 3 1 p 3 30 80 86. 6 100. 0 100.0 55.0 100. 0 100.0 100. 0N3, 84 82. 5 100. 0 100. 0 52, 3 100. 0 100.0 100.0 96 72.2 100.0 100.0 45.8, 91.6 100.0 100.0 100 69. 3 100. 0 100. 0 44. 0 87. 9 100.0 100, 0 104 6 97. 6 '97. 6 42, 3 84. 6 --97.-6 97, 108 164.2 83. 7 83, 7 40. 7 81. 4 83.7 83. 7 120 154. 6 54. 6 54.6 36. 6 54. 6 54-.6 54. 6 1 54, 6 36 80 72.2 100.0 100.0 45, 8 91. 6 100.0 100.0 100. 0 84 68; 8 100: 0 100. 0 43, 6 1 87, 2 100. 0 100. 0 100. 0 6 60.2 100.0 100.0 38.2 76.3 100.0 93.3 100.0 100 57.8 100. 0 100.0 36.6 73.3 100.0 89.6 100.0 104 55. 5 100. 0 1 100. 0 35. 2 70, 5 100.01 86.2 1 100. 0 108 53, 5 85. 7 85. 7 33. 9 67. 9 85. 7 83.0 1 85. 7 .120 48. 1 55.8 55.8 30.5 35.8 55.8. 55.8 55.8 42 80 61.9 100.0 100.0 39.3 78.5 100.0 96.0 100.0 84 58.9 100, 0 100. 0 37. 4 74. 8 100. 0 91, 4 100. 0 96 51.6 100, 0 100. 0 32. 7 65. 4 98. 1 80.0 100.0 100 49. 5 99. 0 100, 0 31. 4 62.8 94.2 76. 8 100.0 104 - 47. 6 87, 3 87. 3 30.2 60. 4 B7. 3 .73. 8 87. 3 108 45.8 74.7 74.7 29. 1 58.2 74.7 71. 1 74.7 120 41. 3 48. 4 48. 4 26.2 48. 4 48.4. 48.4 48, 4 48 80 54. 2 100. 0 100. 0 34. 4 68. 7 . 100, 0 84.0 100. 0 84 51. 6 100. 0 100.0 32, 7 65. 4 98, 1 80.0 100. 0 Be 49.2 98.5 100.0 31.2 62.5 93.7 76.4 100.0 92 47. 1 94.2 100.0 29.9 59.7 89.6 73.0 100.0 96 45. 1 90. 3 100. 0 28. 6 57. 3 85. 9 70.0 100, 0 100 43. -3 86. 6 91. 9 27.5 .55. 0 82. 4 67.2 91. 9 104 41, 7 78. 0 78.0 26. 4 52. 8 78. 0 64.6 78. 0 105 41. 1 73.4 73.4 26.0 52. 1 73.4 63.7 73.4 52 80 50, 0 100. 0 100. 0 31.7 63. 4 95. 1 77. 5 TO0. 0 84 47. 6 95, 2 100. 0 30.2 60. 4 90: 6 73.8 100. 0 88 45. 4 90. 9 100. 0 28.8 57. 7 1 86. 5.70. 5 100. 0 97.5 41._0 82.0 96.0 26.0 52.0 78.0 63.6 96.0 60 80 43.3 86.6 98.3 27.5 55.0 82.4 67.2 99.3 82 42. 3 84, 5 97. jI 26, 8 53. 6 1 80. 41 65.6 97. 3 84 41. 3 1 82. 5 96, O 26. 2 52. 3 1 78. 51 64. 0 96. 0 TABLE 3 EXAMPLEi DOOR MODULE= 48' -- FRAME HEIGHT= 96' HEADER & SILL ANCHOR TYPE A - WITH I CLUSTER - MAXIMUM PRESSURE PD= t 45.1 PSF WITH 2 CLUSTER - MAXIMUM PRESSURE PD= t 90.3 PSF WITH 3 CLUSTER - MAXIMUM PRESSURE PD= ±100.0 PSF _ NUMBER OF CLUSTERS (n) ANCHORS ANCHORS -16�-A2 MOC 24'❑C U aC3 �zo 0 U f � X < aQ =w U U z¢ ¢ o_ L7 ID I I I TRACK OPTION I I I I I I II L - - - - - MANUFACTURER: S �]E SOUTHEASTERN MenWecW, a&WaR+ fMgw,,Do 1505 COMMERCE LANE, P.O. BOX 794 JUPITER, FLORIDA 33458 PHONE: (561)746-5493 FAX: (561) 575-1826 PRODUCT: ANCHORS ATLAS PLUS ,,ANCHORS AT MAX. 24' OC AT MAX, ---{ 24' ❑C SERIES 5000 ALUMINUM I SLIDING GLASS DOOR SMALL MISSILE IMPACT - -7�--p- - - - -, Engineering: 1 TRACK TEnq(ffO Jnr. III TRACK RAC OPTION CA8116 6971 W. Sunrise Blvd. 104 I.I OPTION i i Y,o Plantation, Fl IiI I I r ENGCOPA Cog f/GG� -_ s i �Q�a;. GENSF •.,�Fo i I . I-G4) I I 7 I \ �t.FE '�5 2010 w/ i t�NF W/RaF'. I ���• En ee i5A21 =•Q �� �_ IiI I I III I I DRAFTING _��i•�iiiuiAal if i I i i i PN DRAFTING & MORE MIAMI-DADE BCCO: TRACK --j 6 r- ADDUCT RfiV1SED TYPICAL PAIR OF ANCHOR OPTION wmplgin wittift Flarida CLUSTERED IN 1, 2 OR 3 SETS adding Code ccepaNo SPACED AT 6' OC 'on on Dnu SEE TABLE 3 FOR CAPACITY MINIMUM EDGE ANCHOR TYPES, ➢ISTANCE <E. D, ) A- 1/4' TAPCON BY ITW WITH 1 3/4' MIN, 'EMBEDMENT INTO 3000 psi CONCRETE 2 1/2' B- 1/4' TAPCON BY ITW WITH 1 1/4' MIN.. EMBEDMENT INTO HOLLOW BLOCK 2 1/2' C- 1/4' TAPCON BY ITW WITH 1 1/2' MIN. EMBEDMENT INT❑ PT WOOD (SG=.55) 3/4' D- 1/4-14 SS SHEET METAL SCREWS INTO 1/8' METAL STRUCTURES 1/2' NOTES- 1- MINIMUM EMBEDMENT ARE BEYOND WALL DRESSING, 2- TAPCONS WITH FLAT, HEX AND/OR PAN HEADS CAN BE USED. 3- METAL STRUCTURES ARE ASTM A36 STEEL OR 6063-T6 ALUMINUM 4- ANCHOR TYPE D MUST HAVE A MINIMUM 3 THREADS EMBEDMENT Date: 02/05/10 Scale: NA Design by: PPMF Drawing Number 09-220R1 SHEET 8of13 FRAMING ANCHORAGE SELECTION TABLE 4 - (3,4 OR 5 TRACK FRAMING) ANCHORAGE CAPACITY IN PSF FUNCTION OF ANCHOR TYPE AND NUMBER OF CLUSTERS ANCHOR TYPE A C MODULE FRAME D IDTH HE GHT 1 3 1 2 3 30 80 86. 6 100. 0 100.0 55. 0 100.0 100. D 100, 0 2 100. 0 84 82.5 100. 0 100, 0 52. 3 100. 0 100. 0 100, 0 100. 0 96 72. 2 100. 0 100. 0 45, 8 91.6 100. 0 100. 0 100. 0 L 00 69. 3 100. 0 100.0 44.0 87. 9 100. 0 100. 0 100. 0 104 6. 6 97, 6 97, 6 42. 3 84.6 97. 6 9. 6 108 64. 2 83. 7 Al7 40. 7 81, 4 83. 7 83. 7 36 180 72. 2 100, 0 I 100, 0 45. 8 9t. 6 100. 0 100. 0 100. 0 84 68, 8 100. 0 100. 0 43. 6 87. 2 100, 0 100, 0 100. 0 96 60. 2 100. 0 100. 0 31.2 76.3 IOD, 0 93. 3 100. 0 100 57. 8 100. D 100. 0 36.6 73.3 100. 0 89. 6 100. 0 104 55. 5 100. 0 100. 0 35, 2 70.5 100. 0 86, 2 100. 0 109 53.5 85.7 85.7 33.9 67.9 85.7 83.0 85.7 42 120 48. 1 55.8 55.8 30.5 55.8 55.8 55.8 55.8 80 61, 9 100. 0 100. 0 39. 3 78.5 100. 0 96. 0 10D, 0 84 58.9 100.0 100.0 37.4 74.8 300.0 91.4 100.0 96 51. 6 100. 0 100. 0 32, 7 65. 4 98. 1 80. 0 100; 0 100 49. 5 100. 0 31. 4 62. 8 94.2 76.8 1 100. 0 104 47. 6 87, 3 87. 3 30, 2 60. 4 87. 3 73. 8 87. 3 108 45.8 74. 7 74. 7 29. 1 58. 2 74. 7 71, 1 48 180 54. 2 100. 0 100. 0 34. 4 68. 7 140, 0 84. 0 0 84 51.6 100.0 100.0 32.7 65.4 98.1 80.0 -00. 100.0 88 49. 2 98. 5 100. 0 31. 2 62. 5 93. 7 76, 4 100. 0 92 47. 1 94.2 100.0 29.9 59.7 89. 6 73.0 100.0 96 41 90. 3 100. 0 -28, 6 57. 3 85. 9 70. 0 100. 0 10 43. 3 86. 6 91. 9 27. 5 55, 0 82. 4 67. 2 91. 9 1044 41. 7 78. 52 I80 41. 173. 4 63, 7 73. 4 80 50.0 195.2 100.0 31.7 63.4100.0 84 47. 6 95, 2 100. 0 30. 2 60. 4 90, 6 73. 8 100. 0 88 45. 4 90.9 100. 0 28. 8 57. 7 86. 5 70, 5 100.97. 0 5 60 80 43. 86.6 B. 3 27. 5 55. 0 82, 4D 97. 2 98, 82 42. 3 84.5 97. 3 26. 8 84 41. 3 82.5 96.0 2- - 52.3 78. 5 64.0 96.0 TABLE 4 EXAMPLE, DOOR MODULE= 48' -- FRAME HEIGHT= 96' HEADER & SILL ANCHOR TYPE A: WITH 1 CLUSTER - MAXIMUM PRESSURE PD= ±45.1 PSF WITH 2 CLUSTER - MAXIMUM PRESSURE PD= ±90.3 PSF WITH 3 CLUSTER - MAXIMUM PRESSURE PD= ±100 PSF _ NUMBER [IF CLUSTERS (n) ANCHORS 6 AT MAX. 24' OC I a I r-M I � I TRACK v j I OPTION piX < I 3: I I a¢ I I I I I TRACK LOPTION � L- - - - -- ANCHORS ANCHORS AT MAX. AT MAX. 24' DC 24' OC TYPICAL PAIR OF ANCHOR CLUSTERED IN 1, 2 OR 3 SETS SPACED AT 6'DC SEE TABLE 4 FOR CAPACITY I.- MINIMUM EMBEDMENT ARE BEYOND WALL DRESSING. 2- TAPCONS WITH FLAT, HEX AND/OR PAN HEADS CAN BE USED. 3- METAL STRUCTURES ARE ASTM A36 STEEL OR 6063-T6 ALUMINUM 4- ANCHOR TYPE D MUST HAVE A MINIMUM 3 THREADS EMBEDMENT ANCHORS AT MAX, 24'OC TRACK OPTION I I � I a_ I I 5 I 4 I 7 I I I I I I -1I I TRACK OPTION MANUFACTURER: S®E SOUTHEASTERN uenmewmnr armneoi x.want ssmno co:. � 1505 COMMERCE LANE, P.O. BOX 794 JUPITER, FLORIDA 33458 PHONE: (561) 746-5493 FAX: (561) 575-1826 ATLAS PLUS SERIES 5000 ALUMINUM SLIDING GLASS DOOR SMALL MISSILE IMPACT Engineering: +En.g(2 31tr CA 8116 6971 W. Sunrise Blvd. 104 9�-�EBr�'io101U 'Q ggppg�g� � • 6V �'(�pArbf�4Wrs�,��11�� Js/ •dll DRAFTING PK DRAFFING & MORE MIAMI-DADE BCCO: LODUCr REVISED complying with the Flocide d1ding Code xepl... No .Q 0 pnation De1e 20 Date: 02/05/10 Scale: NA Oesfgn by: PPMF Drawing Number 09-22OR1 SHEET 9of13 2. ' 1. 50 99 O 1. SD - I LCS 1, 28 1. 28 .". 0. 25 0. 10 2-TWO TRACK HEADER ALLOY:6063-T6 6.04 1.50 1. 53 1. 53 1. 50 0 1.28 1.28 I. 28 - 1. 28 cu 0 25 0, t0 26- FOUR TRACK HEADER ALLOY: 6063-T6 iN 0 6 3- 3-1/4" TWO TRACK SILL ALLOY: 6063-T6 ' 2' THRESHOLD LIMITED TO +50 PSF 36- 3-1/4' FOUR TRACK SILL ALLOY: 606348 ' 2' THRESHOLD LIMITED TO +50 PSF DOOR FRAMING MANUFACTURER: MINIMUM S 2-1/2' 1. 13 j1- 50 1.53 1.50 o-' 0. 63 SOUTHEASTERN T0 o - I 1505 COMMERCE LANE, P.O. BOX 794 28I.28 a 1/4' JUPITER. FLORIDA 33458 21- JAMB SHEAR CLIP D IAM 0 08 PHONE: (561) 746-5493 ALUMINUM 6063-T6 HOLE FAX: (561) 575-1826 0.25 0. 10 ALLOY:602A- THREE TRACK HEADER 0. OB N Cu ATLAS PLUS ALLOY:6083-T6 0 n 1. 13 d a SERIES 5000 ALUMINUM 7. 0, 63 SLIDING GLASS DOOR 57 SMALL MISSILE IMPACT 1. 50 1. 53 1. 53 �+- I. 53 t. 50 �� T- m N p, pp I I o " Engineering: -L +Enq(9 Jnr. T a FiF 1. 28 1. 28 1. 28 1, 28 Cu r CA 8116 6971 W. Sunrise Blvd. 104 o M 1A- THREE TRACK JAMB PlantatiglVWOTM4 0, 25 0 10 m o ALLOY:8063-T6 ENC/+�E�'('� 2C- FIVE TRACK HEADER �tdQ�O ALLOY:6063-Tfi d4�0;.'JG SF'••,.Fpo•, 0. 13.4 ice- 7 • No. '; 1-TWOTRACKJAMB 5.20 ALLOY:8063-TB -1 1. 13 FERr• a0�0: I 4. 70 -t} I--• 1. 40 ---i i- t. 4D i--- 1. 4D 1 II L N m ■ T N O I'1 3A- 3-1/4' THREE TRACK SILL ALLOY: 6063-T8 ' 2' THRESHOLD LIMITED TO+50 PSF 3C-3.1/4' FIVE TRACK SILL ALLOY: 6063-T6 2' THRESHOLD LIMITED TO +50 PSF 0. T63 DRAFTIfSUiaii::1i��I0.PK DRAFTING &MORE MIAMI-DADE BCCO: 0. 08RODUCTREVISED mplyitigwith the FloriildingCodemtancexo ha ion Date 0�3 rt N O � etni a odtut Control ivision m Date:02/05/10 Scale: NA � N _T N Design by: PPMF O 0� o Drawing Number T T 09-220R1 1 B-FOUR TRACK JAMB ALLOY:6063-T6 IC- FIVE TRACK JAMB SHEET ALLOY:6083-T6 10 of 13 DOOR PANEL COMPONENTS & BILLOF MATERIALS 0. 08 2 1. 81 a 0. 88 0. 90 cu 1, 72 ro n I n o co n N N 1. 02 n a 3 0 �o C3 r n1 .. �l. 90 3. 50 --� 1. 14 I-•- 5- DOOR TOP RAIL 4-ATLAS INTERLOCK ALLOY:6063-T6 ALLOY: 6063-T6 ONLY ON OPERABLE PANELS 2. 50 0. D8 0.54 0, 08 0. 88 0. 90 1. 72 ..7�� 1. 72 � N � mT� Zoo 9- DOOR END RAIL ALLOY: 6063-T6 -3. 50 ----� 8- DOOR BOTTOM RAIL I ALLOY: 6063-T6 m �r 1.63 L o In `* � d 0.93 0, 10 OPTIONAL FRAME m In 0. 08 co In j 1-- SNAP COVER CiIn o o ALLOY: 6063-T6 13- GLAZING GASKET j c3 OF - EXTRUDED PVC 75 DUROMETER 11- GLAZING ADAPTER MARINE GASKET PARTA 992 ALLOY:6063-TS MADE BY TEAM PLASTICS, INC. 6-ATLAS END RAIL ALLOY:6063-T6 BILL OF MATERIALS # DESCRIPTION MATERIAL SUPPLIER 1 TWO TRACK JAMB ALUMINUM 6063-T6 SOUTHEASTERN DOOR COMPANY IA THREE TRACK JAMB ALUMINUM 6063-T6 SOUTHEASTERN DOOR COMPANY 1B FOUR TRACK.JAMB ALUMINUM 6063-T6 SOUTHEASTERN DOOR COMPANY 1C FIVE TRACK JAMB ALUMINUM 6063-T6 SOUTHEASTERN DOOR COMPANY 2 TWO TRACK HEADER ALUMINUM 6063-T6 SOUTHEASTERN DOOR COMPANY 2A THREE TRACK HEADER ALUMINUM 6063-T6 SOUTHEASTERN DOOR COMPANY 2B FOUR TRACK HEADER ALUMINUM 6063-T6 SOUTHEASTERN DOOR COMPANY 2C IFIVE TRACK HEADER ALUMINUM 6063-T6 SOUTHEASTERN DOOR COMPANY 3 TWO TRACK SILL ALUMINUM 6063-T6 SOUTHEASTERN DOOR COMPANY 3A THREE TRACK SILL ALUMINUM 6063-T6 SOUTHEASTERN DOOR COMPANY 3B FOUR TRACK SILL ALUMINUM 6063-T6 SOUTHEASTERN DOOR COMPANY 3C FIVE TRACK SILL ALUMINUM 6063-T6 SOUTHEASTERN DOOR COMPANY 4 ATLAS INTERLOCK ALUMINUM 6063-T6 SOUTHEASTERN DOOR COMPANY 5 DOOR TOP RAIL ALUMINUM 6063-T6 SOUTHEASTERN DOOR COMPANY 6 ATLAS END RAIL ALUMINUM 6063-T6 SOUTHEASTERN DOOR COMPANY 7 ATLAS DOOR ASTRAGAL ALUMINUM 6063-T6 SOUTHEASTERN DOOR COMPANY 8 DOOR BOTTOM RAIL ALUMINUM 6063-TG SOUTHEASTERN DOOR COMPANY 9 DOOR END RAIL ALUMINUM 6063-T6 SOUTHEASTERN DOOR COMPANY 10 1/4' PILE WEATHER-STRIP PILE W31255BNG ULTRAFAB 11 GLAZING ADAPTER ' ALUMINUM 6063-T5 SOUTHEASTERN DOOR COMPANY 12 OPTIONAL SNAP COVER ALUMINUM 6063-T5 SOUTHEASTERN DOOR COMPANY 13 GLAZING GASKET EXTRUDED VINYL TEAM PLASTIC 17 1 11/16' DIAM, ROLLER TANDEM ROLLER AMESBURY 17A 1 I1/16' DIAM. ROLLER SINGLE ROLLER AMESBURY 18 #2815-84 I ULTI-POINT LOCK AMESBURY 19 #2470-84 KEEPER AMESBURY 20 . ATLAS INTERLOCK REINF. (FULL LENGTH) ALUMINUM 6063-T6 SOUTHEASTERN DOOR COMPANY 21 IJAMB SHEAR CLIPI ALUMINUM 6063-T6 SOUTHEASTERN DOOR COMPANY 22 ISEALANT VULKEN 116 1 POLYURETHANE TREMCO WEATHER STRIPPING OPERABLE PANELS W1 INTERLOCK STILE IULTRAFAB W31205 SINGLE FIN 3/8' PILE HEIGHT W2 INILHLUUK SIILL 10.638xG.382 TEAM PLASTICS BULB VINYL PART 1 VT- I UPAI A 1 SINGLE FIN 3?8' PILE HEIGHT- W4 BOTTOM RAIL I ULTRAFAB W31255 SINGLE FIN 1/2' PILE HEIGHT W5 ASTRAGAL ULTRAFAB W31155BNG SINGLE FIN 3/8' PILE HEIGHT FIXED PANELS W61 INTERLOCK STILE ULTRAFAB W3426BNG SINGLE FIN 3/8' PILE HEIGHT It INTERLOCK STILE 0.638x0.382 TEAM PLASTICS BULB VINYL PART 191 W3 I TOP RAIL I ULTRAFAB W31175 SINGLE FIN 3/8' PILE HEIGHT W4 I BOTTOM RAIL ULTRAFAB W31255 SINGLE FIN 1/2' PILE HEIGHT FRAME W3 JAMB I ULTRAFAB W31175 SINGLE FIN 3/8' PILE HEIGHT W7 SILL IN,. VEEP HOLE UXUU 1/2' WEEP DRAIN PAN PLUG PART#890 0-2618 L.24 1.67 I CLUSTER OF MINIMUM FOUR DIAM WEEP HOLES T 0. 10 1 I AT EA DRAIN PAN �T 2e 0.25 �,3 1 1/8x1' OPENING 0.20 �r =1- FACTORY APPLIED DRAIN PAN 7-ATLAS DOOR ASTRAGAL 20-ATLAS INTERLOCK LOCATED AT CENTERLINE OF EACH PANEL ALLOY:6063-T6 REINFORCEMENT -6063-T6 SEE SHEET 2 OF 13 MANUFACTURER: S M SOUTHEASTERN M,nur,aaonmmroonRo9slnNsra�s orns,man 1505 COMMERCE LANE, P.O. BOX 794 JUPITER, FLORIDA 3345E PHONE: (561) 746-5493 FAX: (561) 57.5-1826 PRODUCT: ATLAS PLUS SERIES 5000 ALUMINUM SLIDING GLASS DOOR SMALL MISSILE IMPACT Engineering: +FttgTjor Jrtr CA 8116 6971 W. $U1Y/9uA",104 A'• FWA F201b�$�r DRAFTING, PK RRARING & MORE MIAMI-DADE BCCO: RODUCTREVISED s complying with the Florida luilding Code rcceptance No, - . ixpua 'an ale. (3 •T ty�� diaml Product Contra HvWon Date: 02/05/10 Srala: NA Design by: PPMF Drawing Number 09-220R1 SHEET 11 of 13 DOOR HARDWARE 18— DEADLOCK 1 MULTIPOINT MORTISE LOCK PER LOCK MEETING STILE HARDWARE SUPPLIER, AMESBURY PART H2e15-e4 19 - STRIKE PLATE ATTACHED TO THE DOOR WITH (2) k6X 1/4' SS. FLAT HEAD SCREWS. I KEEPER PER MEETING STILE OR JAMB 10. 137 -HARDWARE SUPPLIER- AMESBURY PART #2470-84 ATTACHED AT JAMB OR ASTRAGAL RAIL 0 O O O 0 USING FOUR W/ 010-16X 1-1/2'PHSMS. 10, l30 56 2. 5 5. 662 / 0 00 - .00 0 0 0 O O 0 0 0, 13 1. 969 . 75 3. -37 17A— SINGLE WHEEL ASSEMBLY 17— TANDEM WHEEL ASSEMBLY 2 PER FIXED DOOR PANEL 2 PER OPERABLE DOOR PANEL HARDWARE SUPPLIER. AMESBURY HARDWARE SUPPLIER. AMESBURY PART a1966-7000-12 PART a1966-7501.-14 ADJUSTABLE 111/16' DIAMETER NYLON ROLLER ADJUSTABLE-1 11/16' DIAMETER NYLON ROLLER ASSEMBLY WITH ALUMINUM HOUSING ATTACHED TO ASSEMBLY WITH ALUMINUM HOUSING ATTACHED TO THE BOTTOM RAIL USING ONE 1/4'X1'SS ROD. .THE BOTTOM RAIL USING ONE 1/4'XI SS ROD. DOOR HARDWARE TYPICAL LOCATIONS 1 1 3 O 4 X 5 X 4 X 4 7 LOCK 7 7 W/RE F. pW/REM WIRPTF. 6 WIRE F. m 13 13 y // 2 2 MANUFACTURER: -s® SOUTHEASTERN a� tcwem mnwarromsunesaennsm, oawr 1505 COMMERCE LANE, P.O. BOX 794 JUPITER, FLORIDA 33458 PHONE: (561) 746.5493 FAX: (561).575-1826 - PRODUCT: ATLAS PLUS SERIES 5000 ALUMINUM SLIDING GLASS DOOR SMALL MISSILE IMPACT Engineering: +.Ett-gTer 3ttr-. CA 8116 6971 W. Sunrise B1Wd. 104 DRAFTING, - """ - PK RRAFTMNG & MORE MIAMI-DADE BCCO: CT REVISED R 2ODWDU11 nt3 with the Florida K Date: 02/05/10 Scale: NA Design by: PPMF Drawing Number 09-220R1 SHEET 12of13 0. 25 DOOR CORNER ASSEMBLY _J L-- ---4 1.00 1--- ALL DOOR PANEL JOINTS TO BE SEALED BY USING A BEAD OF SEALANT TOP RAIL — — — #1 PER CORNER) #14X1' SSPH SMS VERTICAL STILES TOP RAIL SQUARE CUT to N Uri APPLICABLE ONLY FOR REINFORCED DOORS I/4-1X5-1/4' 6063-T6 ALUMINUM STRESS BAR LOCATED BETWEEN THE INTERLOCK VERTICAL STILES AND TOP AND BOTTOM RAILS CORNERS VERTICAL STILE TOP ENDS ARE NOTCHED TO RECEIVE BOTTOM RAIL RIBS AND SECURED BY (2) 014X1 SS (1 PER CORNER) #14X1' SSPH SMS VERTICAL STILE BOTTOM ENDS (1 INT❑ ROLLER ASSEMBLY) ARE NOTCHED TO RECEIVE #14X1' SSPH SMS BOTTOM RAIL RIBS AND ------- SECURED BY (1) #14X1 SS AT RAIL AND (1) #14X1 SS INTO ROLLER u � JLLU BOTTOM RAIL BOTTOM RAIL SQUARE CUT VERTICAL STILE TOP & BOTTOM RAIL - LL V 0-- ps� - STRESS BAR SEALANTS FRAMING CORNER ASSEMBLY FRONT VIEW MANUFACTURER; S SOUTHEASTERN SECTION VIEW+wnuracru,�mwmnana..immxw,�cw,cm•, 1505 COMMERCE LANE, P.O. BOX 794. JUPITHEADER PHONER561)746-5493, FLORIDA 8 SQUARE CUT PHONE: () 57 -1 8-5493 FAX:(581)575.1826 JAMB NOTCHED PRODUCT: TO RECEIVE ATLAS PLUS ' HEADER RIBS SERIES 5000 ALUMINUM SLIDING GLASS DOOR SMALL MISSILE IMPACT JAMB NOTCHED Engineering: TO RECEIVE I IU,jT SILL RIBS CA 8116 6971 W. Sunrise alvd.104 SILLiI APPLY BEAD OF SEALANT AT � SILL TOP AND BOTTOM JOINTS SQUARE CUT .JAMB SHEAR CLIP ASSEMBLY JAMB^CLIP^AT.EACH PERIMETER SEALANT - VULKEN 116 POLYURETHANE SEALANT FRAME JOINT SEALANT - CRL SILICONE OR VULKEN POLYURETHANE SEALANT DOOR PANEL JOINT SEALANT - CRL SILICONE OR VULKEN POLYURETHANE SEALANT NQZW09 1 _� Qm15 2af� �O�Ccs g ISe�I ad 4e, ,1 .inirrr DRAFTING. " PK DRAFTING MRE MIAMI-DADE BCCO: RODUCT REVISED t complying with the Florida uilding Code cceptance No rryiredoa ate. 2"01i. - - �1 8 ade Ptodtttt Control Date: 02/05/10 Scale: NA Design by: PPMF Drawing Number, 09-22OR1 SHEET, 13 of 13