HomeMy WebLinkAboutunderlaymentCIP
7-REC:'S
VEb
MAR 'lnx�J
gT, Lucie County, PermiLtin9
NEMO I etc.
Certificate ofAuthorizatioa #32455
Christian Street, Unit #13
Oxford, CT 06478
(203)262-9245
ENGINEER EVALUATE TEST ICONSULT CERTIFY
Polyglass USA, Inc. Evaluation Report P12060.02.09-R25
1111 West Newport Center Drive FL5259-R29
Deerfield Beach, FL 33442 Da to of Issuance: 02/24/2009
(954) 233-1230 Revision 25: 10/14/2019
SCOPE:
This Evaluation Report Is Issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed Iby Robert Nieminen, P.E. for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 6" Edition (2017) Florida Building Code sections noted herein.
DESCRIPTION: Polyglass Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named products) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, IP.E. of any changes to the
product(s), the Quality Assurance or the production facility location(s). NEMO(etc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMbletc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be donein its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 16
Prepared by: sn;•r1::.... -
Robert J.M. Nieminen, P.E. '-•". = j^
Florida Re[JISClOt%On NO. $9166, Florida DCA ANE1983 The facsimile seat appearing was authorized by Robert Nieminen, P.E. an
f 10/24/2019. This does net serve as an electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMOIetc. does not have, nor does it intend to acquire or will it acquire, a financial interest in my company manufacturing or
distributing products it evaluates.
2. NEMO ( etc. is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other!entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEM01 etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
02019 NEMO ETC, LLC
REVIEWED FILE PY CODE COMP FOR
ST. LUCIE CIOUNTY
BOCC
n
NEMO I etc.
1. SCOPE:
Product Category: Roofing
Sub -Category:
Underlayment
Compliance Statement:
Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated
compliance with the
following sections of the
6th Edition (2017) Florida Building Code through testing in accordance with the
following Standards.
Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1504.3.1
Wind Uplift
FM 4474
2011
1504.3.1
Wind Uplift
UL1897
2012
1507.2.3 / 1507.1.1
Physical Properties
ASTM D226
2099
1507.2.4 / 1507.1.1,1507.2.9.2 Physical Properties
ASTM D1970
2015
1507.3.3
Physical Properties
FRSA/TRI April 2022
2012
1507.11.2
Physical Properties
ASTM D6163
2008
1507.11.2
Physical Properties
ASTM D6164
2011
1S07.11.2
Physical Properties
ASTM D6222
2011
1507.11.2
Physical Properties
ASTM D6509
2009
TAS 110
Accelerated Weathering
ASTM 04798
2011
Entity
Examination
Reference
Date
Entity
Examination
Reference
Date
ERD(TST 6049)
Wind Uplift
11757.08.01-1
08/13/2001
ERD ITST 6049)
Tensile adhesion
P40390.G4.15
G4/03/2015
ERD (TST 6049)
Wind Uplift
11776.06.02
01/16/2003
ERD (TST 60491
TAS 103
P44360.10.14-R1
05/18/2015
ERD (TST 6049)
Wind Uplift
P3740.01.07
01/04/2007
ERD (TST 60491
Wind Uplift
PLYG-SC8905.05.16-1
CS/17/2016
ERD (TST 6049)
ASTM D1970
P5110.04.07-1
04/11/2007
ERD (TST 6049)
ASTM D1970
PLYG-SC10130.06.16-1
06/27/2026
ERD(T5T 6049)
Wind Uplift
P926D.03.08
03/21/2008
ERD (TST 6049)
Tensile adhesion
PLYG-SC30130.06.16-2
06/27/2016
ERD (TST 6049)
Wind Uplift
P30540.11.09-RI
11/30/2009
ERD (TST 6049)
TAS103
PLYG-SC30130.05.16-3
06/27/2016
ERD (TST 6049)
Tensile Adhesion
P11030.11.09-1
11/30/2009
ERD (TST 6049)
ASTM 01970/D4798
PLYG-SC8080.07.16
07/16/2016
ERD(TST 60491
Wind Uplift
P11030.11.09.2
11/30/2009
ERD (TST 6049)
Wind Uplift
PLYG-SC32025.10.16
10/12/2016
ERD (TST 6049)
ASTM D4977
P11030.1L09-3
11/30/2009
ERD (TST 6D49)
TA5103
PLYG.SC13G40.12.16
12/27/2016
ERD (TST 6049)
ASTM D1970
P33360.06.30
06/25/2010
ERD ITST 6D491
30/90 physicals
PLYG-SC11900.03.17
03/10/2017
ERD (TST 6049)
TA5103
P33370.03.11
03/02/2011
ERO(TST 6049)
TAS103
PLYG-SCIZ135.08.17
08/08/2017
ERD ITST 6049)
Tensile Adhesion
P33370.04.11
04/26/2011
ERO(TST 6049)
TA5103
PLYG.SC13035.08.17
10/31/2017
ERD (TST 6049)
ASTM D1970
P37300.30.11
10/19/2011
FM (TST 1867)
Wind Uplift
3004091
01/12/2000
ERD(TST 6049)
TAS103
P40390.08.12-1
08/06/2012
ICC-ES(EVL 2396)
IBCCompliance
ESR-2697
04/01/2019
ERD(TST 60491
Tensile Adhesion
1`40390.08.124
08/07/2012
M-D(CER 1592)
HVHZ Compliance
NOA 17-0514.22
07/06/2017
ERD (TST 6049)
Tensile Adhesion
C41420.09.12-3
09/11/2012
MT](TST Z5081
ASTM D4798
1g20H7A
04/0112009
ERD (TST 6049)
Wind Uplift
P39680.03.13
03/04/2013
NEMO (rST 6049)
ASTM D1970
4-PLYG-18-004.03.18
03/29/2018
ERD (TST 6049)
ASTM D1970
P45370.04.13
04/26/2013
NEMO (TST 6049)
Wind Uplift
4L-PLYG-18-003.01.19
01/11/2019
ERD (TST 6049)
Wind Uplift
P1738.02.67-112
04/29/2013
NEMO (TST 6049)
ASTM D6163
4S-PLYG-18-002.01.19-A
01/24/2019
ERD (TST 6049)
Wind Uplift
11757.04.01-1-R1
04/30/2013
NEMO (TST 6049)
ASTM D6222
45-PLYG-16-002.05.19-C
05/20/2019
ERD (M 6049)
ASTM 06164
P37590.03.13-3A
05/06/2013
NEMO (TST 6049)
TAS103
45-PLYG-18-004.10.1943
10/08/2019
ERD (TST 6049)
ASTM D6509
P37590.03.13-1-R1
06/26/2013
NEMO (TST 6049)
TAS103
4S.PLYG-18.004.10.19-1
10/08/2019
ERD (TST 6049)
Wind Uplift
P41630.08.13
08/06/2013
NEMO (TST 6049)
TAS103
4S-PLYG-18-004.30.19-L
10/09/2019
ERD(TST 6049)
ASTM D4601
P45940.09.13
09/04/2013
NEMO (TST 6049)
TAS103
4j-PLYG-I9-SSU0L-01.A
10/10/2019
ERD (TST 6049)
Wind Uplift
P31751.05.03-R1
11/26/2013
PRI M5878)
Tensile Adhesion
PRIO1111
04/08/2002
ERD(TSr6049)
Wind Uplift
P11781.S1A3.R1
11/26/2013
PRI(TST 5878)
TA5103
PUSA-0M02-01
07/14/2003
ERO(TST 6049)
30/90 physicals
P45270.05.14
05/12/2014
PRI(TST 5878)
TA5103
PUSA-035-02-01
09/29/2006
ERD (TST 6049)
Tensile adhesion
6020.09.14-5
09/08/2014
PRI(TST 5878)
TA5103
PUSA-055.02-02
12/10/2007
ERD(TSr 6049)
Tensile adhesion
6020.09.14-6
09/08/2014
PRI(TST 58781
ASTM D6222
PUSA-061.02-02
01/28/2008
ERD (TST 6049)
Tensile adhesion
P46520.10.14
10/03/2014
PRI(T5T 5878)
ASTM D6164
PUSA-088.02-01
07/29/2009
ERD (TST 6049)
ASTM D1970/D479B
P43290.30.14
10/17/2014
Polyglass USA
P/(.Affidavit
Mule -Hide Cross Ltg
03/0112008
NEMO ETC, U.C.
Evaluation Report P12060.02.09-R25
certificate ofAum4n7ation e32455
6`"
EDITION (2017)FSC
NON-HVH2 EVALUATION
FL5259-R29
Polyglass Raof Underlayments;
(9541 233-1230
Revision
25: 10/14/2019
Page 2 of 16
Lim Examination
ERD (TST 6049) TAS 103
4.
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
4.10
4.11
4.12
4.13
4.14
4.15
4.16
4.17
i
i
� NNEMOjetc.
Reference Date Enti Examination Reference Date
PLYG-SC7550.03.15 03/24/21L Polyglass USA Materials Affidavit Polystick Compound 08/18/2011
UL (QUA96Z5) Quality Can Vol Service confirmation 09/13/2018
PRODUCr DESCRIPTION: I _
Product
Specification
Plant(s)
Description
Elastobase
ASTM D6163
FL
Fiberglass -reinforced, SBS modified bitumen base sheet
Elastobase P
ASTM D6164
FL
Polyester -reinforced, SBS modified bitumen base sheet
Elastoflex G TU
M-D 13-004
PA
Polyester -reinforced, modified bitumen tile underlayment
FRSA/TRI April 2012
composed of a sand-surfaceh SBS modified bitumen back-
side and granule -surfaced APP modified bitumen top -side
Elastoflex 56 G
ASTM D6164
FL
Polyester -reinforced, SBS modified bitumen cap sheet
FRSA/TRIApril 2012
1 1
Elastoflex 56 G FR
ASTM D6164
FL
Polyester -reinforced, SBS modified bitumen cap sheet
FRSA/TRI April 2012
j I
Mule -Hide SA-APP Cap Sheet
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet
FRSA/TRI April 2012
I I
HydraGuard Dual Pro
ASTM D1970
FL
Nominal 60-mil thick dual-laier rubberized asphalt
waterproofing membrane, fiberglass reinforced, with a
polyester fabric surface I
HydraGuard Tile Pro
ASTM D1970
FL
Nominal 60-mil thick dual -layer rubberized asphalt
TAS 103
waterproofing' membrane, fiberglass reinforced, with a
FRSA/TRI April 2012
polyester fabric surface 1
Mule -Hide SA-APP Cap Sheet
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet
(FR)
FRSA/TRI April 2012
I I
Polyflex G
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet for
FRSA/TRI April 2012
use as an alternate to Heat Applied "Cap Sheet" in the
"Two Ply System" from FRSAI/TRI April 2012 (04-12)
beneath mechanically fastened or adhered tile roof
systems
Polyflex G FR
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet for
FRSA/TRI April 2012
use as an alternate to Heat Applied "Cap Sheet" in the
"Two Ply System" from FRSAI/TRI April 2012 (04-12)
beneath mechanically fastened tile roof systems
Polyflex SA P
ASTM D6222
FL
Polyester -reinforced, APP modified
bitumen cap sheet
FRSA/rRI April 2012
Polyflex SA P FR
ASTM D6222
FL
Polyester -reinforced, APP modified
bitumen cap sheet
FRSA/TRI April 2012
-
1
Polyglass Base
ASTM D6509
FL
Fiberglass -reinforced, APP modified
bitumen base sheet
Polyglass G2 Base Sheet
ASTM D4601
AL
Fiberglass -reinforced, asphaltic
base sheet
Polystick IR-Xe
ASTM D1970
FL, PA
Nominal 60-mil thick rubberized
asphalt waterproofing
membrane, glass fiber reinforced,
with an aggregate
surface
Polystick MTS Plus
TAS 103
FL, PA, TX
Nominal 60-mil thick rubberized
asphalt waterproofing
FRSA/TRI April 2012
membrane, glass fiber reinforced,
surfaced with
polyolefinic f6n surface
I
NEMO ETC, U.C. Evaluation Report P32060.02.09-R25
Certifxote ofAuthorkation 032455 6-EDITION 12017) FRC NON-HVHZ EVALUATION FLSZ59.RZ9
Polyglass Roof Underlayments; (954) Z33.IZ30 Revision 25: 10/24/2019
Page 3 of 16
r
C
NNEMOletc.
4. PRODUCT DESCRIPTION:
Product
Specification
Plant(s)
Description
4.18
Pol stick MU-
ASTM D1970
FL, NV, PA
Nominal54-mil thick dual -layer rubberized asphalt
(See Section 5.8)
waterproofing membrane, fiberglass reinforced, with a
-
polypropylene film surface
4.19
PolystickTU Max
ASTM D1970
FL, PA, TX
Nominal 60-mil thick rubberized asphalt waterproofing
TAS 103
membrane with a 190 g/m2 polyester fabric surface
FRSA/TRI April 2012
—4.
olystick TU P
TAS 103
TX
Nominal 130-mil thick rubberized asphalt waterproofing
FRSA/TRI April 2012
membrane, glass-fiber/polyester reinforced, with a
granular surface
4.21
Polystick TU Plus
ASTM D1970
FL, PA
Nominal 80-mil thick rubberized asphalt waterproofing
TAS 103
membrane, glass fiber reinforced, with a polyester fabric
FRSA/TRI April 2012
surface
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither NEMOI etc. nor Robert Nieminen, P.E. are, in anyway, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless
retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of
this product.
5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within
FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this
evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
Wood Shakes
Underlayment
Asphalt Shingles
Nail -On Tile
Foam -On Tile
Metal
&Shingles
Slate
Elastobase
Yes
Yes
Yes
Yes
Yes
Yes
(Base Sheet in 2-ply system)
(Base Sheet in 2-ply system)
Elastobase P
Yes
Yes
Yes
yes
Yes
Yes
(Base Sheet in Dplysystem)
(Base Sheet In 2-ply system)
Polyglass Base
No
Yes
Yes
No
No
No
(Base Sheet In 2-plysystem)
(Base Sheet N 2ro1v system)
Polyglass G2 Base
No
Yes
Yes
No
No
No
(Base Sheet in 2-ply system)
(Base Shen in2 plY system)
Elastoflex G TU
Yes
Yes
Yes (See 5.5.11
No
Yes
Yes
Elastoflex S6G
Yes
Yes
Yes (See5.5.1)
No
Yes
Yes
Elastoflex S6 G FR
Yes
Yes
No
No
Yes
Yes
HydraGuard Dual Pro
Yes
No
No
Yes
Yes
Yes
HydraGuard Tile Pro
Yes
Yes
Yes (See 5.5.1)
Yes
Yes
Yes
Mule -Hide SA-APP Cap
Sheet
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Mule -Hide SA-APP Cap
Sheet(FR)
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
PolyflexG
Yes
Yes
Yes (See 5.5.11
No
Yes
Yes
Polyflex G FR
Yes
Yes
o
No
Yes
Yes
Polyflex SA P
Yes
ye;
Yes (i ee5.5.1)
No
Yes
Yes
Polyflex SA P FR
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Polystick IR-Xe
Yes
No
No
No
Yes
Yes
NEMO ETC, I.I.C. Evaluation Report P12060.02.09-R25
Ceimj+cote p/Apthontorion 032455 6^' EDITION(20171 FBC NON-HVHZ EVALUATION FL5259-R29
Polyglass Roof Underlayments; (954) 233-1230 Revision 25: 10/14/2019
Page 4 of 16
5.5.1
5.6
r-I
u
NNEMOjetc.
TABLE 1: iROOF COVER OPTIONS;I.
_ 1
Undedayment
Asphalt5hingles
Nail -On Tile
Foam -On Tile
Metal
Ng
1
Wood Shakes
&Shingles
Slate
Polystick MTS Plus
Yes
Yes
No
Yes (
Yes -
Yes
Yes
No
No
Yes (
Yes
Yes
Polystick TU Max 17
No
Yes
Yes (See 5.5.11
Yes I
No
No
No
Yes
Yes (See 5.5.1)
No (
No
No
Polystick TU Plus
Yes
Yes
Yes (See 5.5.1)
Yes (
Yes
Yes
"Foam -On Tile" is limited to use of the following Approved tile adhesives / underleyment combinations.
TABLEIA: ALLOWABLE TILE ADHESIVE If UNDERLAYMENT GOM_BINATIONst
Florida Product
Adhesive
Approval
I Underlaymen is
DAP Foam Touch'n Seal StormBond
FL14506
I
Polystick TU Max Polystick TU Plus
Roof Tile Adhesive
or
HydraGuard Tile Pro, Polyfllex SA P, Polystick TU Max, Polystick TU P or
Dow TileBond"
FL22525
Polystick TU Plus I
Elastoflex G TU, Elastaflex S6 G, HydraGuard Tile Pro, Mule -Hide 5A-APP
ICP Adhesives Polyset® AH-160
FL6332
Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex G, Polyflex SAP,
Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus
Elastaflex 56 G, HydraGuard Tile Pro, Mule°!Hide SA-APP Cap Sheet, Mule-
ICP Adhesives Polyset° RTA-1
FL6276
Hide SA-APP Cap Sheet (FR), Polyflex G, Po flex: SA P, Polyflex SA P FR,
Polystick TU Max, Polystick TU P or Polystic TU Plus
Allowable Substrates:
_ TABLEZ: -SUBSTRATE OPTIONS FOR ADHERED UNOERLAYMENTS 1
Substrates (designed to meet wind loads, for project)
Underlayment
Application
Type Primer Material(s)
plywood, OSB, Southernl/ellow Pine or Huffer
HydraGuard Duet
Deck /
(Optional) ASTM D41
Engineered Woods "21P System" Panels
HydraGuard Tile Prro,o,
sheathing
' ASTM D41structural
concrete
Polystick (all variations),
self-
ASTM C1289 Type II Class 1 polyisocyanurate, ASTM
Mule -Hide SA-APP Cap
adhering
Insulation
(Optional) ASTM D41
C1289 Type Vpolyisocyanurate-compositea DensDeck
Sheet, Mule -Hide SA-APP
or WB-3000
,
Prime o[SECUROCK Gypsum-Fiber'Roof Board
Cap Sheet (FR), Polyflex
Base
N/A
ASTM D226 felt, Elastobase, Elastobase P or Mule -Hide
SA P or Polyflex SA P FR
Sheet
Nail Base 8
Deck
ASTM D41
structural concrete 0
ElastoflexG TU, Elastoflex
hot asphalt
Insulation
(Optional) ASTM D41
DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board
Base
ASTM 0226 felt, Elastobase, Elastobase P, Mule -Hide Nail
S6 G or Elastoflex S6 G FR
Sheet
N/A
Base or Polyglass G2 Base
Deck
ASTM D41
structural concrete i
Polyflex G or Polyflex G FR
torch-
Insulation
(Optional) ASTM D41
DensDeck Prime or SECUROCK ,Gypsum -Fiber Roof Board
Base
Elastobase, Elastobase P,1 Mule -Hide Nail Base, Polyglass
applied
Sheet
N/A
G2 Base or Polyglass Base
I
r Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida Product Approval for OverturningMoment Resistance Performance.
NEMO ETC, LLC. ! IEvaluation Report P32060.02.09-R25
Certificate 01Avthariration a324SS 6a'EDITION (2017) FBC NON.HVH2 EVALUATION FL5259-1129
Polyglass Roof Underlayments; (9S4) Z33-1230 Revision 25:10/14/2019
Page 5 of 16
r-�
NNEW10letc.
5.6.1 Wind Resistance for Underlayment systems in Foam -On Tile Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptively addressed in FRSA/fRI April
2012 (04-12) and are used in foam -on or mortar -set tile applications. Maximum Design Pressure is the result of testing for
wind load resistance based on allowable wind loads and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin
of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table SA or FBC 1609
for determination of design wind loads.
#1 Maximum Design Pressure=-52.5 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Joints: Min. 4-inch wide strips of Elastoflex SA-V over all OSBjoints
Base Ply: Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FRI, Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
92 Maximum Design Pressure=-90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: None
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#3 Maximum Design Pressure=-97.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1Y." ring shank nails
through 32 ga.,1-5/8" diameter tin caps spaced 12-inch o.c.
#4 Maximum Design Pressure=-105 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: WB-3000
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1Y." ring shank nails
through 32 ga., 1-5/8" diameter tin caps spaced 12-Inch o.c.
#5 Maximum Design Pressure =-135 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional) PG100 or ASTM D41
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Joints: Min. 4-inch wide strips of Elastoflex SA-V over all plywood joints.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
46 Maximum Design Pressure=-315 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FRI, Polyflex SA P, Polyflex SA P FR,
Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered.
#7 Maximum Design Pressure = -622.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction,
Primer: PG100 or ASTM D41
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
NEMO ETC, U.C. Evaluation Report P32060.02.09-R25
Certfmte of Autho&ation#32455 6r"EDITION(20171 FBC NON-HVHZ EVALUATION FL5259.RZ9
Polyglass Roof Underlayments; (954) 233-1230 Revision 25; 10/14/2019
Page 6 of 16
#8
#9
410
#11
0
ONEMOletc.
Maximum Design Pressure=-30.0 Dsf•:
Deck: Min. 15/32-inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga, x 1.25-inch long x 1-Inch head diameter round metal cap nails
Spacing: 5-Inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS Plus, self -adhered. I
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex IA P, Polyflex Sp P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered. gppy
Maximum Design Pressure=-37.5 Dsf•:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
i
Fasteners: 11 ga. x 1.25-Inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex S P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
Maximum Design Pressure=-37.5 Dsf•:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One (1) or two (2) layers ASTM D226, Type 11 felt
Fasteners: - 11 ga. x1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. i
i
Maximum Design Pressure =-45 Dsf•:
Deck: Min. 19/32-Inch plywood to meet project requirements to satisfaction of Authority Having I Jurisdiction.
Base Sheet: One (1) layer ASTM D226, Type 11 felt 1yy
Fasteners: 11 ga. x 1.25-inch x 3/94nch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c. at the 2-Inch wide side laps and 4-inch o.c. at two (2) equally spaced staggeredcenter rows.
Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (Fit), Polyflex SA P, Polyflex SA P FR, Polystick TU Max; Polystick
TU P or Polystick TU Plus, self -adhered or Elastoflex G TU, applied In full mopping of hot asphalt.
#12 Maximum Design Pressure =-45 Dsf•
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Two (2) layers ASTM D226, Type II felt.
Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch
diameter tin caps
Spacing: -9-inch o.c. at the 2-inch wide side laps and 9-inch o.c. at two (2) equally spaced staggered
center rows.
Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA
P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered or Elastoflex G TU or Elastoflex 56 G, applied infull
mopping of hot asphalt.
#13 Maximum Design Pressure =-45 Dsf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AuthorityHaving
Jurisdiction.
Base Sheet: Elastobase (sanded tap surface for hot -asphalt or torch -applied cap or poly-flim surface for
torch -applied cap)
Fasteners: Simplex MAX)( Cap Fasteners I .
Spacing: 9-inch o.c. at the 2-inch wide side laps and 18-inch o.c. at two (2) equally spaced staggere
center rows.
Underlayment Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch
-applied.
gI@
#14 Maximum Design Pressure =-45.0 Dsf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, 05B sheathing to meet project requirements to
satisfaction of Authority Having
Jurisdiction. j
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 12 ga. annular ring shank nails with 1-5/8" diameter tin caps
Spacing: 6-inch o.c. at the 3-Inch wide side laps and 6-inch o.c. at four (4) equally spaced stagger
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FRI, Polyflex SA P, Polyflex
TU P or Polystick TU Plus, self -adhered.
rows.
P FR, Polystick TU Max, Polystick
NEMO ETC, LLC. Evaluation Report P32060.02.09-R25
certificate ofAuthorliation 032455 6^ EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-RZ9
Potyglass Roof Underlayments; (954) 233-1230 Revision 25:10/14/2019
Page 7 of 16
r�
NNEMO[etc.
#15 Maximum Design Pressure = -45.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSS sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: 12 ga. annular ring shank nails with 1-5/8" diameter tin caps
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt.
#16 Maximum Design Pressure =-45.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: 12 ga. annular ring shank nails with 1-5/8" diameter tin caps
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-Inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
U17 Maximum Design Pressure=-52.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 55 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#18 Maximum Design Pressure =-52.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: Simplex Original Cap Nails -
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex 5A P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#19 Maximum Design Pressure =-52.5 psf
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-Inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#20 Maximum Design Pressure =-60 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: 11 ga. x 1.25-Inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
U21 Maximum Design Pressure=-60 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip with OMG Flat Bottom Metal Plates
Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
NEMO ETC, U.C. Evaluation Report P32060.02.09-R25
Ccrtiifcotc ofAwhoriwmt 932455 6^'EDITION (2017)FBC NON-HVH2 EVALUATION FLS259-R29
Polyglass Roof Underlayments; (954) 233-1230 'Revision 25: 10/14/2019
Page 8 of 16
C�
,
i
#22 Maximum Design Pressure=-60.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements I
Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8-inch D.C. at the 3-inch wide side laps and 8-Inch D.C. at three (3) equally spaced staggere
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule-HideSA-APP Cap Sheet, Mule-HideSA-APP Cap Sheet (FR), Polynex SA P, Polyflex SF
TU P or Polystick TU Plus, self -adhered.
#23 Maximum Design Pressure =-60.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements t
Jurisdiction...
Base Sheet: Elastobase (sand top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8-inch o.c. at the 3-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggere
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt.
#24 Maximum Design Pressure=-60.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project. requirements t
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: Simplex MAXX Cap Fasteners ,
Spacing: 8-inch o.c. at the 3-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggere
Underlayment: Polyflex G, torch -applied.
#25 Maximum Design Pressure=-67.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Havinj
Base Sheet: Polyglass G2 Base or Polyglass Base (requires use of torch -applied underlayment)
Fasteners: 12 ga. x 1.25-inch long x 3/8-Inch head diameter annular ring shank roofing nails at 1-5/8-
Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at four (4) equally spaced staggered
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied t
#26 Maximum Design Pressure =-67.5 psf: ,
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements I
Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate Installed 180° into
the width direction of the sheet. I
Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced stagger
Primer: (Optional) PG100 or ASTM D41 primer applied to stress plates. I
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule-HideSA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SP
TU P or Polystick TU Plus, self -adhered.
#27 Maximum Design Pressure =-67.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements I
Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into
the width direction of the sheet.
Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-Inch o.c. at two (2) equallyspaced stagger
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. 1
ONEMOletc.
I satisfaction of Authority Having
center rows.
P FR, Polystick TU Max, Polystick
satisfaction of Authority Having
center rows.
satisfaction of Authority Having
center rows.
Jurisdiction.
Ich diameter tin caps
:enter rows.
Polyflex G, torch -applied.
I satisfaction of Authority Having
he holes of the plate, parallel to
d center rows.
P FR, Polystick TU Max, Polystick
I satisfaction of Authority Having
he holes of the plate, parallel to
d center rows.
NEMO ETC, U.C. Evaluation Report P12060.02.09-R25
Cemfirote ofAurhoniadon 032455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-RZ9
Polyglass Roof Underlayments; (954) 233-2230 Revision 25: 10/14/2019
Page 9 of 16
ONEMOletc.
#28 Maximum Design Pressure =-67.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to
the width direction of the sheet.
Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#29 Maximum Design Pressure =-75 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass Base (requires use of torch -applied underloyment)
Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with OMG Flat
Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners
Spacing: 10-inch o.c. at the 4-inch wide side laps and 10-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied.
#30 Maximum Design Pressure=-90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
1#31 Maximum Design Pressure =-90 psf:
Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#32 Maximum Design Pressure =-90 psf:
Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastaflex S6 G, applied in full mopping of hot asphalt.
N33 Maximum Design Pressure=-90 psf:
Deck:
Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Polyglass G2 Base or Polyglass Base (requires use of torch -applied underloyment)
Fasteners:
Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with OMG Flat
Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners
Spacing:
9-inch o.c. at the 4-Inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment:
Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied.
#34 Maximum Design Pressure =-90.0 psf:
Deck:
APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet:
Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners:
TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate Installed 180' into the holes of the plate, parallel to
the width -direction of the sheet
Spacing:
9-Inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Primer:
PG100 or ASTM D41 primer applied to stress plates.
Base Ply:
(Optional) Polystick MTS Plus, self -adhered.
Underlayment:
Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FRI, Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
NEMO ETC, LLC. Evaluation Report P32060.02.09-R25
Certificate ofAuthodmtion 0324S5 6"'EDITION (2017) FBC NON.HVHZ EVALUATION FLS2S9.RZ9
Polyglass Roof Underlayments; (9541 233-1230 Revision 25: 10/14/2019
Page 10 of 16
H35
#36
#37
#38
#39
#40
#41
Maximum Design Pressure =-90.0 osf: �
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements
Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' intc
the width -direction of the sheet I
Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggerc
Underlayment: Elastoflex G TU or Elastoflex S6 6, applied in full mopping of hot asphalt. i
Maximum Design Pressure =-90.0 osf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base -
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' intc
the width -direction of the sheet
Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggere
Underlayment: Polyflex G, torch -applied.
Maximum Design Pressure =-97.5 osf: I
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Havin
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch
Spacing: 4-inch o.c. at the 4-inch wide side laps and 4-inch o.c at four (4) equally spaced staggerec
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FRI, Polyflex SA P, Polyflex Si
TU P or Polystick TU Plus, self -adhered.
Maximum Design Pressure=-97.5 osf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathingto meet project requirements
Jurisdiction. i
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggerec
Primer: PG100 or ASTM D41 primer applied to stress plates. I
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FRI, Polyflex SA P, Polyflex S)
TU P or Polystick TU Plus, self -adhered.
Maximum Design Pressure=-97.5 osf:
Deck: APA rated, 19/32 CAT, 0.578In., Exposure 1, OSB sheathing to meet project requirements
Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggerec
Underlayment: Elastoflex 6 TU or Elastoflex 56 G, applied in full mopping of hot asphalt.
Maximum Design Pressure =-97.5 osf: ,
Deck: APA rated, 19/32 CAT, 0,578 in., Exposure 1, OSB sheathing to meet project requirements
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-Inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally solaced staggerec
Underlayment: Polyflex G, torch -applied.
Maximum Design Pressure =-105 osf:
Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Havin
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap Or poly -Rim surface R
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-Inch o.c. at three (3) equally spaced staggere
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, ton
NEMO ETC, I.I.C.
Ceni(r#te o/Authodwtion#324SS 6- EDITION (2017) FBC NON-HVHZ EVALUATI Ot
Polyglass Roof Undedayments, (954) 233-2230
ONEIVIOletc.
o satisfaction of Authority Having
ithe holes of the plate, parallel to
d center rows.
o satisfaction of Authority Having
the holes of the plate, parallel to
J center rows.
(,Jurisdiction.
diameter tin raps
center rows.
P FR, Polystick TU Max, Polystick
o satisfaction of Authority Having
center rows.
P FR, Polystick TU Max, Polystick
0 satisfaction of Authority Having
center rows.
o satisfaction of Authority Having
center rows.
Jurisdiction.
r torch -applied cap)
J center rows.
h-applied.
Evaluation Report P32060.02.09-1125
FL5259-R29
Revision 25: 10/14/2019
Page 11 of 16
NNEMOletc.
#42 Maximum Design Pressure = -105.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastabase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Primer: PG300 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#43 Maximum Design Pressure = -105.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase (sand tap surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elasto0ex G TU or ElastoRex S6 G, applied in full mopping of hot asphalt.
U44 Maximum Design Pressure=-105.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' Into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
U45 Maximum Design Pressure = -112.5 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer at all tin -caps
Base Ply: Polystick MTS Plus, self -adhered
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#46 Maximum Design Pressure =-120 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip or OMG 414 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows.
Underlayment: ElastoRex G TU or ElastoRex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#47 Maximum Design Pressure =-120 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-Inch o.c. at five (5) equally spaced staggered center rows.
Underlayment: ElastoRex G TU or ElastaRex S6 G, applied In full mopping of hot asphalt.
NEMO ETC, U.C. Evaluation Report P32060.02.09-RZ5
Cenifthrate ofAuthuri:otion a32J55 6" EDITION IZO171 FBC NON-HVHZ EVALUATION FL5259-R29
Polyglass Roof Underlayments; (954) 233-1230 Revision 25: 10/14/2019
Page 12 of 16
#48 Maximum Design Pressure = -127.5 psf: Nenno I etc.
Deck: APA rated, 19/32 CAT, 0.578 In., Exposure 1, 058 sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole.
Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered. I
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SAP FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#49 Maximum Design Pressure=-127.5 psf: ,
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction. I
Base Sheet: Elastobase (sand top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole.
Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mapping of hot asphalt.
i
#50 Maximum Design Pressure = -127.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, O56 sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole.
Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied. 1
5.6.1.1 All other direct -deck, adhered Polyglass underlayment systems beneath foam -on the systems carry a Maximum Design
Pressure of -45 psf. I I
5.6.1.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that
required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure
determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a
qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDS, FM Loss
Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk' carry the
limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations: I
TABLE 3: EXPOSURE LIMITATIONS
Underlayment
'Maximum
Exposure (days)
Elastoflex G TU, HydraGuard Dual Pro, HydraGuard Tile Pro, Polystick MTS Plus, Polystick TU
Max, Polystick TU P or Polystick TU Plus
180
Polystick IR-Xe or Polystick MU-X
0
90
Elastobase, Elastobase P, Polyglass G2 Base or Polyglass Base
'
30
180
Elastoflex S6 G, Elastoflex S6 G FR, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA -API Cap Sheet
(for adhesive -set tile)
UNLIMITED
(FR), Polyflex G, Polyflex G FR, Polyflex SA P or Polyflex SA P FR
(for
mechanically fastened roof
prepared roof covers)
5.8 Polystick MU-)( has been found through comparative testing to have a lesser coefficient of
felt in a dry condition, tested at standard laboratory conditions. Agreement between pur
Section 4.3, Note 1 of ASTM D1970-15, should be established as to slip resistance.
i
NEMO ETC, U.C.
CeRhcate afAut#adrada.#32455 6- EDITION (2017) FBC NON-HVHZ EVALUATION
Polyglass Roof Underlayments; (954) 233-1230
than ASTM D226 roofing
and seller, as set forth in
eport P32060.02.09-R25
FLSZS9-RZ9
Revision 25:10/14/2019
Page 13 of 16
NNEMOletc.
5.9 Tile Slippage Limitations (FRSA/TRI April 2012 (04-121):
When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These
slope limitations can only be exceeded by using battens during loading of the roof tiles.
TAB LE 2: TILE SUPPAGE LIMITATIONS
FOR DIRECFDECK TILE INSTALLATIONS
Underlayment
Tile Profile
Staging Method
Maximum Slope
Elastoflex G TU
Flat
10-tile stack
7:12
Lugged
8-tile stack (6 over 21
6:12
Elastoflex S6 G or S6 G FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
HydraGuard Tile Pro
Flat or Lugged
6-tile stack (4 over 2)
7:12
Polyflex G or G FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polyflex SA P or SA P FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polystick MTS Plus
Flat
6-tile stack (4 over 2)
5:12
Lugged
6-tile stack (4 over 2)
4:12
Polystick TU Max
Flat
6-tile stack (4 over 2) or 10-tile stack
7:12
Lugged
6-[itestack(4over2)
7:12
Lugged
10-tile stack
6:12
Polystick TU P
Flat
6-tile stack (4 over 2)
6:12
Lugged
6-tile stack (4 over 2)
4:12
Polystick TU Plus
Flat or Lugged
6-tile stack (4 over 2)
7:12
Flat or Lugged
10-tile stack
6:12
6. INSTALLATION:
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements subject to the
Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust
and debris prior to application, and prime the substrate (if applicable).
6.3 Elastobase, Elastobase P or Mule -Hide Nail Base:
6.3.1 Non -Tile Applications:
Shall be installed in compliance with the codified requirements for ASTM D226, Type II underlayment in FBC Table 1507.1.1 for
the type of prepared roof covering to be installed and Polyglass published requirements.
Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP, Polyflex SA P FR, Mule -
Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered, Elastoflex G TU, Elastoflex 56 G or Elastoflex 56 G FR in hot
asphalt or Polyflex G or Polyflex G FR, torch applied. Roof cover limitations are those are those associated with the top -layer
underlayment, as set forth in Table 1.
6.3.2 Tile Applications:
Elastobase, Elastobase P or Mule -Hide Nail Base are limited to use as a mechanically attached base sheet in the "Two Ply
System" from FRSA/TRI April 2012 (04-12). Reference is made to Table 1 and Section 5.6.1 herein, coupled with FRSA/TRI April
2012 (04-12) Installation Manual.
NEMO ETC, U.C. Evaluation Report P12060.02.09-R25
Cenifrcare 0Aurhado6oa 02455 6- EDIT] ON (2017) FBC NON-HVHZ EVALUATION FL5259-R29
Polyglass Roof Underlayments; (954) 233-1230 Revision 25: 10/14/2019
Page 14 of 16
•
�J
6.4 HydraGuard Dual Pro, HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide S
Polyflex SA P FR, Polystick IR-Xe, Polystick MTS Plus, Polystick MU-X, Polystick TU Max,
6.4.1 General:
All seal -lap seams (selvage laps) must be firmly rolled with a in
accordance with Polyglass requirements to ensure full contact
and adhesion. For HydraGuard Dual Pro and HydraGuard Tile
Pro, align the edgeofthe top sheet to the end of the glue
pattern (the sheet will overlap the fabric).
View of Ovelap Seam of HydraGuard
6.4.2 Non -Tile Applications:
Shall be installed in compliance with the codified requirements for ASTM D1970 (except Polys
Table 1507.1.1 for the type of prepared roof covering to be installed and Polyglass published r(
6.4.3 Tile Applications /excludes HydraGuard Dual Pro, Polystick 1R-Xe and Polystick MU-X):
Shall be installed in compliance with the requirements for Self -Adhered Membrane set forth in
Polyglass published requirements.
For mechanically fastened the roofing over 2-ply system, consisting of Base Sheet and self -ad
fastening shall be not less than FRSA/TRI April 2012 (04-12), Table 1.
For adhesive -set tile applications, refer to Section 5.6.1 herein.
6.4.4 Multi-PlyUnderlavment Systems:
Polystick MTS Plus followed by HydraGuard Tile Pro, Polyflex SA P, Polystick MTS Plus, Poll
Polystick TU P or Polystick TU Plus is allowable for use under mechanically attached prepared
those associated with the top -layer material. This is not a requirement, but is'allowable if t
desired. I
Polystick MTS Plus followed by HydraGuard Tile Pro, Polyflex SA P, Polystick Tl) Max, Polysti
allowable for use under adhesive -set tile systems. Limits of use are those associated with the
requirement, but is allowable if a 2-ply underlayment system is desired.
6.5
6.5.1
Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR: f
Elastoflex GTU, Elastoflex S6 G or Elastoflex56 G FR shall be installed in compliance with current
requirements. For use in tile applications:
✓ Elastoflex GTU is for use as an alternate to "Mineral Surface Roll Roofing" (AST M D6380, Cla
from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the H
in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or
✓ Elastoflex S6 G is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Cla,
from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the H
in the'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened of
✓ Elastoflex 56 G FR is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D63
System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened the roof systems I
Sheet" in the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fast
�MU
Sheet (FR), Polyflex SA P,
U P or Polystick TU Plus:
Pro and HydraGuard Tile Pro
TU P) underlayment in FBC
April 2012 (04-12) and
top sheet(s), Base Sheet
MU-X, Polystick TU Max,
systems. Limits of use are
ly underlayment system is
TU P or Polystick TU Plus is
-layer material. This is not a
published installation
M) in the "Single Ply System"
Asphalt applied "Cap Sheet"
dhered tile roof systems.
M) in the "Single Ply System"
Asphalt applied "Cap Sheet"
dhered'tile roof systems.
I, Class M) in the "Single Ply
the Hot Asphalt applied "Cap
ed the roof systems.
NEMO ETC, I.I.C. i Evaluation Report P12060.02.09-R25
Certifmre o(Authonzatlen 032455 6- EDITION (2017) FBC NON.HVHZ EVALUATION FL5259-RZ9
Polyglass Roof Underlayments; (954) 233-1230 Revision 25:10/14/2019
Page 15 of 16
NNEMOjetc.
6.5.2 For hot -asphalt -applications, Elastoflex GTU, El a stoflexS6G or Elastoflex S6 G FR shall be fully asphalt -applied to the substrates
noted in Table 2. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, off -set minimum 3 feet from course
to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately
3/8-inch beyond the lap edge.
6.6 I Polyflex G or Polyflex G FR:
6.6.1 Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements. For use
in the applications:
✓ Polyflex G is for use as an alternate to the Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-
12) beneath mechanically fastened or adhered tile roof systems (Refer to Table 2 for base sheet options).
✓ Polyflex G FR is for use as an alternate to the Heat Applied "Cap Sheet' in the "Two Ply System" from FRSA/TRI April 2012
(04-12) beneath mechanically fastened tile roof systems (Refer to Table 2 for base sheet options).
6.6.2 Polyflex G or Polyflex G FR shall be fully torch -applied to the substrates noted in Table 2. Side laps shall be minimum 3-inch and
end -laps minimum 6-inch wide, off -set minimum 3 feet from course to course. Side and end laps shall be fully heat -welded and
inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge.
6.7 Tile Staging:
6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Table 2
herein, and Polyglass published requirements for tile staging.
6.7.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRI April 2012 (04-12) must be used on all roof
slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or nail -boards, to prevent the
sliding and/or damage to the underlayment during the loading process.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
8. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C. 6113203 QA requirements. Refer to
Section 4 herein for product & production locations having met codified physical properties specifications.
9. QUALITY ASSURANCE ENTITY:
UL, LLC—QUA9625; (314) 578-3406; k.chancellor@us.ul.com
- END OF EVALUATION REPORT -
NEMO ETC, I.I.C. Evaluation Report P32060.02.09-R25
Certifimte ofAuthorimtion #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FLSZ59-RZ9
Polyglass Roof Underlayments; (954) 233-1230 Revision 25: 10/14/2019
Page 16 of 16