HomeMy WebLinkAboutunderlaymentCIP 7-REC:'S VEb MAR 'lnx�J gT, Lucie County, PermiLtin9 NEMO I etc. Certificate ofAuthorizatioa #32455 Christian Street, Unit #13 Oxford, CT 06478 (203)262-9245 ENGINEER EVALUATE TEST ICONSULT CERTIFY Polyglass USA, Inc. Evaluation Report P12060.02.09-R25 1111 West Newport Center Drive FL5259-R29 Deerfield Beach, FL 33442 Da to of Issuance: 02/24/2009 (954) 233-1230 Revision 25: 10/14/2019 SCOPE: This Evaluation Report Is Issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed Iby Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6" Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Polyglass Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named products) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, IP.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO(etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMbletc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be donein its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 16 Prepared by: sn;•r1::.... - Robert J.M. Nieminen, P.E. '-•". = j^ Florida Re[JISClOt%On NO. $9166, Florida DCA ANE1983 The facsimile seat appearing was authorized by Robert Nieminen, P.E. an f 10/24/2019. This does net serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMOIetc. does not have, nor does it intend to acquire or will it acquire, a financial interest in my company manufacturing or distributing products it evaluates. 2. NEMO ( etc. is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other!entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEM01 etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 02019 NEMO ETC, LLC REVIEWED FILE PY CODE COMP FOR ST. LUCIE CIOUNTY BOCC n NEMO I etc. 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind Uplift FM 4474 2011 1504.3.1 Wind Uplift UL1897 2012 1507.2.3 / 1507.1.1 Physical Properties ASTM D226 2099 1507.2.4 / 1507.1.1,1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2022 2012 1507.11.2 Physical Properties ASTM D6163 2008 1507.11.2 Physical Properties ASTM D6164 2011 1S07.11.2 Physical Properties ASTM D6222 2011 1507.11.2 Physical Properties ASTM D6509 2009 TAS 110 Accelerated Weathering ASTM 04798 2011 Entity Examination Reference Date Entity Examination Reference Date ERD(TST 6049) Wind Uplift 11757.08.01-1 08/13/2001 ERD ITST 6049) Tensile adhesion P40390.G4.15 G4/03/2015 ERD (TST 6049) Wind Uplift 11776.06.02 01/16/2003 ERD (TST 60491 TAS 103 P44360.10.14-R1 05/18/2015 ERD (TST 6049) Wind Uplift P3740.01.07 01/04/2007 ERD (TST 60491 Wind Uplift PLYG-SC8905.05.16-1 CS/17/2016 ERD (TST 6049) ASTM D1970 P5110.04.07-1 04/11/2007 ERD (TST 6049) ASTM D1970 PLYG-SC10130.06.16-1 06/27/2026 ERD(T5T 6049) Wind Uplift P926D.03.08 03/21/2008 ERD (TST 6049) Tensile adhesion PLYG-SC30130.06.16-2 06/27/2016 ERD (TST 6049) Wind Uplift P30540.11.09-RI 11/30/2009 ERD (TST 6049) TAS103 PLYG-SC30130.05.16-3 06/27/2016 ERD (TST 6049) Tensile Adhesion P11030.11.09-1 11/30/2009 ERD (TST 6049) ASTM 01970/D4798 PLYG-SC8080.07.16 07/16/2016 ERD(TST 60491 Wind Uplift P11030.11.09.2 11/30/2009 ERD (TST 6049) Wind Uplift PLYG-SC32025.10.16 10/12/2016 ERD (TST 6049) ASTM D4977 P11030.1L09-3 11/30/2009 ERD (TST 6D49) TA5103 PLYG.SC13G40.12.16 12/27/2016 ERD (TST 6049) ASTM D1970 P33360.06.30 06/25/2010 ERD ITST 6D491 30/90 physicals PLYG-SC11900.03.17 03/10/2017 ERD (TST 6049) TA5103 P33370.03.11 03/02/2011 ERO(TST 6049) TAS103 PLYG-SCIZ135.08.17 08/08/2017 ERD ITST 6049) Tensile Adhesion P33370.04.11 04/26/2011 ERO(TST 6049) TA5103 PLYG.SC13035.08.17 10/31/2017 ERD (TST 6049) ASTM D1970 P37300.30.11 10/19/2011 FM (TST 1867) Wind Uplift 3004091 01/12/2000 ERD(TST 6049) TAS103 P40390.08.12-1 08/06/2012 ICC-ES(EVL 2396) IBCCompliance ESR-2697 04/01/2019 ERD(TST 60491 Tensile Adhesion 1`40390.08.124 08/07/2012 M-D(CER 1592) HVHZ Compliance NOA 17-0514.22 07/06/2017 ERD (TST 6049) Tensile Adhesion C41420.09.12-3 09/11/2012 MT](TST Z5081 ASTM D4798 1g20H7A 04/0112009 ERD (TST 6049) Wind Uplift P39680.03.13 03/04/2013 NEMO (rST 6049) ASTM D1970 4-PLYG-18-004.03.18 03/29/2018 ERD (TST 6049) ASTM D1970 P45370.04.13 04/26/2013 NEMO (TST 6049) Wind Uplift 4L-PLYG-18-003.01.19 01/11/2019 ERD (TST 6049) Wind Uplift P1738.02.67-112 04/29/2013 NEMO (TST 6049) ASTM D6163 4S-PLYG-18-002.01.19-A 01/24/2019 ERD (TST 6049) Wind Uplift 11757.04.01-1-R1 04/30/2013 NEMO (TST 6049) ASTM D6222 45-PLYG-16-002.05.19-C 05/20/2019 ERD (M 6049) ASTM 06164 P37590.03.13-3A 05/06/2013 NEMO (TST 6049) TAS103 45-PLYG-18-004.10.1943 10/08/2019 ERD (TST 6049) ASTM D6509 P37590.03.13-1-R1 06/26/2013 NEMO (TST 6049) TAS103 4S.PLYG-18.004.10.19-1 10/08/2019 ERD (TST 6049) Wind Uplift P41630.08.13 08/06/2013 NEMO (TST 6049) TAS103 4S-PLYG-18-004.30.19-L 10/09/2019 ERD(TST 6049) ASTM D4601 P45940.09.13 09/04/2013 NEMO (TST 6049) TAS103 4j-PLYG-I9-SSU0L-01.A 10/10/2019 ERD (TST 6049) Wind Uplift P31751.05.03-R1 11/26/2013 PRI M5878) Tensile Adhesion PRIO1111 04/08/2002 ERD(TSr6049) Wind Uplift P11781.S1A3.R1 11/26/2013 PRI(TST 5878) TA5103 PUSA-0M02-01 07/14/2003 ERO(TST 6049) 30/90 physicals P45270.05.14 05/12/2014 PRI(TST 5878) TA5103 PUSA-035-02-01 09/29/2006 ERD (TST 6049) Tensile adhesion 6020.09.14-5 09/08/2014 PRI(TST 5878) TA5103 PUSA-055.02-02 12/10/2007 ERD(TSr 6049) Tensile adhesion 6020.09.14-6 09/08/2014 PRI(TST 58781 ASTM D6222 PUSA-061.02-02 01/28/2008 ERD (TST 6049) Tensile adhesion P46520.10.14 10/03/2014 PRI(T5T 5878) ASTM D6164 PUSA-088.02-01 07/29/2009 ERD (TST 6049) ASTM D1970/D479B P43290.30.14 10/17/2014 Polyglass USA P/(.Affidavit Mule -Hide Cross Ltg 03/0112008 NEMO ETC, U.C. Evaluation Report P12060.02.09-R25 certificate ofAum4n7ation e32455 6`" EDITION (2017)FSC NON-HVH2 EVALUATION FL5259-R29 Polyglass Raof Underlayments; (9541 233-1230 Revision 25: 10/14/2019 Page 2 of 16 Lim Examination ERD (TST 6049) TAS 103 4. 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 i i � NNEMOjetc. Reference Date Enti Examination Reference Date PLYG-SC7550.03.15 03/24/21L Polyglass USA Materials Affidavit Polystick Compound 08/18/2011 UL (QUA96Z5) Quality Can Vol Service confirmation 09/13/2018 PRODUCr DESCRIPTION: I _ Product Specification Plant(s) Description Elastobase ASTM D6163 FL Fiberglass -reinforced, SBS modified bitumen base sheet Elastobase P ASTM D6164 FL Polyester -reinforced, SBS modified bitumen base sheet Elastoflex G TU M-D 13-004 PA Polyester -reinforced, modified bitumen tile underlayment FRSA/TRI April 2012 composed of a sand-surfaceh SBS modified bitumen back- side and granule -surfaced APP modified bitumen top -side Elastoflex 56 G ASTM D6164 FL Polyester -reinforced, SBS modified bitumen cap sheet FRSA/TRIApril 2012 1 1 Elastoflex 56 G FR ASTM D6164 FL Polyester -reinforced, SBS modified bitumen cap sheet FRSA/TRI April 2012 j I Mule -Hide SA-APP Cap Sheet ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet FRSA/TRI April 2012 I I HydraGuard Dual Pro ASTM D1970 FL Nominal 60-mil thick dual-laier rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface I HydraGuard Tile Pro ASTM D1970 FL Nominal 60-mil thick dual -layer rubberized asphalt TAS 103 waterproofing' membrane, fiberglass reinforced, with a FRSA/TRI April 2012 polyester fabric surface 1 Mule -Hide SA-APP Cap Sheet ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet (FR) FRSA/TRI April 2012 I I Polyflex G ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet for FRSA/TRI April 2012 use as an alternate to Heat Applied "Cap Sheet" in the "Two Ply System" from FRSAI/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems Polyflex G FR ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet for FRSA/TRI April 2012 use as an alternate to Heat Applied "Cap Sheet" in the "Two Ply System" from FRSAI/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems Polyflex SA P ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet FRSA/rRI April 2012 Polyflex SA P FR ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet FRSA/TRI April 2012 - 1 Polyglass Base ASTM D6509 FL Fiberglass -reinforced, APP modified bitumen base sheet Polyglass G2 Base Sheet ASTM D4601 AL Fiberglass -reinforced, asphaltic base sheet Polystick IR-Xe ASTM D1970 FL, PA Nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an aggregate surface Polystick MTS Plus TAS 103 FL, PA, TX Nominal 60-mil thick rubberized asphalt waterproofing FRSA/TRI April 2012 membrane, glass fiber reinforced, surfaced with polyolefinic f6n surface I NEMO ETC, U.C. Evaluation Report P32060.02.09-R25 Certifxote ofAuthorkation 032455 6-EDITION 12017) FRC NON-HVHZ EVALUATION FLSZ59.RZ9 Polyglass Roof Underlayments; (954) Z33.IZ30 Revision 25: 10/24/2019 Page 3 of 16 r C NNEMOletc. 4. PRODUCT DESCRIPTION: Product Specification Plant(s) Description 4.18 Pol stick MU- ASTM D1970 FL, NV, PA Nominal54-mil thick dual -layer rubberized asphalt (See Section 5.8) waterproofing membrane, fiberglass reinforced, with a - polypropylene film surface 4.19 PolystickTU Max ASTM D1970 FL, PA, TX Nominal 60-mil thick rubberized asphalt waterproofing TAS 103 membrane with a 190 g/m2 polyester fabric surface FRSA/TRI April 2012 —4. olystick TU P TAS 103 TX Nominal 130-mil thick rubberized asphalt waterproofing FRSA/TRI April 2012 membrane, glass-fiber/polyester reinforced, with a granular surface 4.21 Polystick TU Plus ASTM D1970 FL, PA Nominal 80-mil thick rubberized asphalt waterproofing TAS 103 membrane, glass fiber reinforced, with a polyester fabric FRSA/TRI April 2012 surface 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMOI etc. nor Robert Nieminen, P.E. are, in anyway, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS Wood Shakes Underlayment Asphalt Shingles Nail -On Tile Foam -On Tile Metal &Shingles Slate Elastobase Yes Yes Yes Yes Yes Yes (Base Sheet in 2-ply system) (Base Sheet in 2-ply system) Elastobase P Yes Yes Yes yes Yes Yes (Base Sheet in Dplysystem) (Base Sheet In 2-ply system) Polyglass Base No Yes Yes No No No (Base Sheet In 2-plysystem) (Base Sheet N 2ro1v system) Polyglass G2 Base No Yes Yes No No No (Base Sheet in 2-ply system) (Base Shen in2 plY system) Elastoflex G TU Yes Yes Yes (See 5.5.11 No Yes Yes Elastoflex S6G Yes Yes Yes (See5.5.1) No Yes Yes Elastoflex S6 G FR Yes Yes No No Yes Yes HydraGuard Dual Pro Yes No No Yes Yes Yes HydraGuard Tile Pro Yes Yes Yes (See 5.5.1) Yes Yes Yes Mule -Hide SA-APP Cap Sheet Yes Yes Yes (See 5.5.1) No Yes Yes Mule -Hide SA-APP Cap Sheet(FR) Yes Yes Yes (See 5.5.1) No Yes Yes PolyflexG Yes Yes Yes (See 5.5.11 No Yes Yes Polyflex G FR Yes Yes o No Yes Yes Polyflex SA P Yes ye; Yes (i ee5.5.1) No Yes Yes Polyflex SA P FR Yes Yes Yes (See 5.5.1) No Yes Yes Polystick IR-Xe Yes No No No Yes Yes NEMO ETC, I.I.C. Evaluation Report P12060.02.09-R25 Ceimj+cote p/Apthontorion 032455 6^' EDITION(20171 FBC NON-HVHZ EVALUATION FL5259-R29 Polyglass Roof Underlayments; (954) 233-1230 Revision 25: 10/14/2019 Page 4 of 16 5.5.1 5.6 r-I u NNEMOjetc. TABLE 1: iROOF COVER OPTIONS;I. _ 1 Undedayment Asphalt5hingles Nail -On Tile Foam -On Tile Metal Ng 1 Wood Shakes &Shingles Slate Polystick MTS Plus Yes Yes No Yes ( Yes - Yes Yes No No Yes ( Yes Yes Polystick TU Max 17 No Yes Yes (See 5.5.11 Yes I No No No Yes Yes (See 5.5.1) No ( No No Polystick TU Plus Yes Yes Yes (See 5.5.1) Yes ( Yes Yes "Foam -On Tile" is limited to use of the following Approved tile adhesives / underleyment combinations. TABLEIA: ALLOWABLE TILE ADHESIVE If UNDERLAYMENT GOM_BINATIONst Florida Product Adhesive Approval I Underlaymen is DAP Foam Touch'n Seal StormBond FL14506 I Polystick TU Max Polystick TU Plus Roof Tile Adhesive or HydraGuard Tile Pro, Polyfllex SA P, Polystick TU Max, Polystick TU P or Dow TileBond" FL22525 Polystick TU Plus I Elastoflex G TU, Elastaflex S6 G, HydraGuard Tile Pro, Mule -Hide 5A-APP ICP Adhesives Polyset® AH-160 FL6332 Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex G, Polyflex SAP, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus Elastaflex 56 G, HydraGuard Tile Pro, Mule°!Hide SA-APP Cap Sheet, Mule- ICP Adhesives Polyset° RTA-1 FL6276 Hide SA-APP Cap Sheet (FR), Polyflex G, Po flex: SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystic TU Plus Allowable Substrates: _ TABLEZ: -SUBSTRATE OPTIONS FOR ADHERED UNOERLAYMENTS 1 Substrates (designed to meet wind loads, for project) Underlayment Application Type Primer Material(s) plywood, OSB, Southernl/ellow Pine or Huffer HydraGuard Duet Deck / (Optional) ASTM D41 Engineered Woods "21P System" Panels HydraGuard Tile Prro,o, sheathing ' ASTM D41structural concrete Polystick (all variations), self- ASTM C1289 Type II Class 1 polyisocyanurate, ASTM Mule -Hide SA-APP Cap adhering Insulation (Optional) ASTM D41 C1289 Type Vpolyisocyanurate-compositea DensDeck Sheet, Mule -Hide SA-APP or WB-3000 , Prime o[SECUROCK Gypsum-Fiber'Roof Board Cap Sheet (FR), Polyflex Base N/A ASTM D226 felt, Elastobase, Elastobase P or Mule -Hide SA P or Polyflex SA P FR Sheet Nail Base 8 Deck ASTM D41 structural concrete 0 ElastoflexG TU, Elastoflex hot asphalt Insulation (Optional) ASTM D41 DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board Base ASTM 0226 felt, Elastobase, Elastobase P, Mule -Hide Nail S6 G or Elastoflex S6 G FR Sheet N/A Base or Polyglass G2 Base Deck ASTM D41 structural concrete i Polyflex G or Polyflex G FR torch- Insulation (Optional) ASTM D41 DensDeck Prime or SECUROCK ,Gypsum -Fiber Roof Board Base Elastobase, Elastobase P,1 Mule -Hide Nail Base, Polyglass applied Sheet N/A G2 Base or Polyglass Base I r Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida Product Approval for OverturningMoment Resistance Performance. NEMO ETC, LLC. ! IEvaluation Report P32060.02.09-R25 Certificate 01Avthariration a324SS 6a'EDITION (2017) FBC NON.HVH2 EVALUATION FL5259-1129 Polyglass Roof Underlayments; (9S4) Z33-1230 Revision 25:10/14/2019 Page 5 of 16 r-� NNEW10letc. 5.6.1 Wind Resistance for Underlayment systems in Foam -On Tile Applications: The following wind uplift limitations apply to underlayment systems that are not prescriptively addressed in FRSA/fRI April 2012 (04-12) and are used in foam -on or mortar -set tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table SA or FBC 1609 for determination of design wind loads. #1 Maximum Design Pressure=-52.5 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Joints: Min. 4-inch wide strips of Elastoflex SA-V over all OSBjoints Base Ply: Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FRI, Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. 92 Maximum Design Pressure=-90 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: None Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #3 Maximum Design Pressure=-97.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1Y." ring shank nails through 32 ga.,1-5/8" diameter tin caps spaced 12-inch o.c. #4 Maximum Design Pressure=-105 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: WB-3000 Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1Y." ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-Inch o.c. #5 Maximum Design Pressure =-135 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) PG100 or ASTM D41 Base Ply: (Optional) Polystick MTS Plus, self -adhered. Joints: Min. 4-inch wide strips of Elastoflex SA-V over all plywood joints. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. 46 Maximum Design Pressure=-315 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FRI, Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #7 Maximum Design Pressure = -622.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction, Primer: PG100 or ASTM D41 Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. NEMO ETC, U.C. Evaluation Report P32060.02.09-R25 Certfmte of Autho&ation#32455 6r"EDITION(20171 FBC NON-HVHZ EVALUATION FL5259.RZ9 Polyglass Roof Underlayments; (954) 233-1230 Revision 25; 10/14/2019 Page 6 of 16 #8 #9 410 #11 0 ONEMOletc. Maximum Design Pressure=-30.0 Dsf•: Deck: Min. 15/32-inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga, x 1.25-inch long x 1-Inch head diameter round metal cap nails Spacing: 5-Inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS Plus, self -adhered. I Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex IA P, Polyflex Sp P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. gppy Maximum Design Pressure=-37.5 Dsf•: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) i Fasteners: 11 ga. x 1.25-Inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex S P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. Maximum Design Pressure=-37.5 Dsf•: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One (1) or two (2) layers ASTM D226, Type 11 felt Fasteners: - 11 ga. x1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. i i Maximum Design Pressure =-45 Dsf•: Deck: Min. 19/32-Inch plywood to meet project requirements to satisfaction of Authority Having I Jurisdiction. Base Sheet: One (1) layer ASTM D226, Type 11 felt 1yy Fasteners: 11 ga. x 1.25-inch x 3/94nch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-inch o.c. at the 2-Inch wide side laps and 4-inch o.c. at two (2) equally spaced staggeredcenter rows. Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (Fit), Polyflex SA P, Polyflex SA P FR, Polystick TU Max; Polystick TU P or Polystick TU Plus, self -adhered or Elastoflex G TU, applied In full mopping of hot asphalt. #12 Maximum Design Pressure =-45 Dsf• Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Two (2) layers ASTM D226, Type II felt. Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: -9-inch o.c. at the 2-inch wide side laps and 9-inch o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered or Elastoflex G TU or Elastoflex 56 G, applied infull mopping of hot asphalt. #13 Maximum Design Pressure =-45 Dsf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AuthorityHaving Jurisdiction. Base Sheet: Elastobase (sanded tap surface for hot -asphalt or torch -applied cap or poly-flim surface for torch -applied cap) Fasteners: Simplex MAX)( Cap Fasteners I . Spacing: 9-inch o.c. at the 2-inch wide side laps and 18-inch o.c. at two (2) equally spaced staggere center rows. Underlayment Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. gI@ #14 Maximum Design Pressure =-45.0 Dsf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, 05B sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. j Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 12 ga. annular ring shank nails with 1-5/8" diameter tin caps Spacing: 6-inch o.c. at the 3-Inch wide side laps and 6-inch o.c. at four (4) equally spaced stagger Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FRI, Polyflex SA P, Polyflex TU P or Polystick TU Plus, self -adhered. rows. P FR, Polystick TU Max, Polystick NEMO ETC, LLC. Evaluation Report P32060.02.09-R25 certificate ofAuthorliation 032455 6^ EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-RZ9 Potyglass Roof Underlayments; (954) 233-1230 Revision 25:10/14/2019 Page 7 of 16 r� NNEMO[etc. #15 Maximum Design Pressure = -45.0 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSS sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sand top surface) Fasteners: 12 ga. annular ring shank nails with 1-5/8" diameter tin caps Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. #16 Maximum Design Pressure =-45.0 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: 12 ga. annular ring shank nails with 1-5/8" diameter tin caps Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-Inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Polyflex G, torch -applied. U17 Maximum Design Pressure=-52.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex 55 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #18 Maximum Design Pressure =-52.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: Simplex Original Cap Nails - Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex 5A P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #19 Maximum Design Pressure =-52.5 psf Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-Inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #20 Maximum Design Pressure =-60 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: 11 ga. x 1.25-Inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. U21 Maximum Design Pressure=-60 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: OMG #12 Standard Roofgrip with OMG Flat Bottom Metal Plates Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. NEMO ETC, U.C. Evaluation Report P32060.02.09-R25 Ccrtiifcotc ofAwhoriwmt 932455 6^'EDITION (2017)FBC NON-HVH2 EVALUATION FLS259-R29 Polyglass Roof Underlayments; (954) 233-1230 'Revision 25: 10/14/2019 Page 8 of 16 C� , i #22 Maximum Design Pressure=-60.0 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements I Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: Simplex MAXX Cap Fasteners Spacing: 8-inch D.C. at the 3-inch wide side laps and 8-Inch D.C. at three (3) equally spaced staggere Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule-HideSA-APP Cap Sheet, Mule-HideSA-APP Cap Sheet (FR), Polynex SA P, Polyflex SF TU P or Polystick TU Plus, self -adhered. #23 Maximum Design Pressure =-60.0 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements t Jurisdiction... Base Sheet: Elastobase (sand top surface) Fasteners: Simplex MAXX Cap Fasteners Spacing: 8-inch o.c. at the 3-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggere Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. #24 Maximum Design Pressure=-60.0 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project. requirements t Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: Simplex MAXX Cap Fasteners , Spacing: 8-inch o.c. at the 3-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggere Underlayment: Polyflex G, torch -applied. #25 Maximum Design Pressure=-67.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Havinj Base Sheet: Polyglass G2 Base or Polyglass Base (requires use of torch -applied underlayment) Fasteners: 12 ga. x 1.25-inch long x 3/8-Inch head diameter annular ring shank roofing nails at 1-5/8- Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at four (4) equally spaced staggered Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied t #26 Maximum Design Pressure =-67.5 psf: , Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements I Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate Installed 180° into the width direction of the sheet. I Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced stagger Primer: (Optional) PG100 or ASTM D41 primer applied to stress plates. I Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule-HideSA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SP TU P or Polystick TU Plus, self -adhered. #27 Maximum Design Pressure =-67.5 psf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements I Jurisdiction. Base Sheet: Elastobase (sand top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the width direction of the sheet. Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-Inch o.c. at two (2) equallyspaced stagger Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. 1 ONEMOletc. I satisfaction of Authority Having center rows. P FR, Polystick TU Max, Polystick satisfaction of Authority Having center rows. satisfaction of Authority Having center rows. Jurisdiction. Ich diameter tin caps :enter rows. Polyflex G, torch -applied. I satisfaction of Authority Having he holes of the plate, parallel to d center rows. P FR, Polystick TU Max, Polystick I satisfaction of Authority Having he holes of the plate, parallel to d center rows. NEMO ETC, U.C. Evaluation Report P12060.02.09-R25 Cemfirote ofAurhoniadon 032455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-RZ9 Polyglass Roof Underlayments; (954) 233-2230 Revision 25: 10/14/2019 Page 9 of 16 ONEMOletc. #28 Maximum Design Pressure =-67.5 psf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to the width direction of the sheet. Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Polyflex G, torch -applied. #29 Maximum Design Pressure =-75 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass Base (requires use of torch -applied underloyment) Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners Spacing: 10-inch o.c. at the 4-inch wide side laps and 10-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied. #30 Maximum Design Pressure=-90 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. 1#31 Maximum Design Pressure =-90 psf: Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #32 Maximum Design Pressure =-90 psf: Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface) Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastaflex S6 G, applied in full mopping of hot asphalt. N33 Maximum Design Pressure=-90 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass Base (requires use of torch -applied underloyment) Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners Spacing: 9-inch o.c. at the 4-Inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied. #34 Maximum Design Pressure =-90.0 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate Installed 180' into the holes of the plate, parallel to the width -direction of the sheet Spacing: 9-Inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FRI, Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. NEMO ETC, LLC. Evaluation Report P32060.02.09-R25 Certificate ofAuthodmtion 0324S5 6"'EDITION (2017) FBC NON.HVHZ EVALUATION FLS2S9.RZ9 Polyglass Roof Underlayments; (9541 233-1230 Revision 25: 10/14/2019 Page 10 of 16 H35 #36 #37 #38 #39 #40 #41 Maximum Design Pressure =-90.0 osf: � Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements Jurisdiction. Base Sheet: Elastobase (sand top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' intc the width -direction of the sheet I Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggerc Underlayment: Elastoflex G TU or Elastoflex S6 6, applied in full mopping of hot asphalt. i Maximum Design Pressure =-90.0 osf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements Jurisdiction. Base Sheet: Elastobase or Polyglass Base - Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' intc the width -direction of the sheet Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggere Underlayment: Polyflex G, torch -applied. Maximum Design Pressure =-97.5 osf: I Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Havin Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch Spacing: 4-inch o.c. at the 4-inch wide side laps and 4-inch o.c at four (4) equally spaced staggerec Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FRI, Polyflex SA P, Polyflex Si TU P or Polystick TU Plus, self -adhered. Maximum Design Pressure=-97.5 osf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathingto meet project requirements Jurisdiction. i Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggerec Primer: PG100 or ASTM D41 primer applied to stress plates. I Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FRI, Polyflex SA P, Polyflex S) TU P or Polystick TU Plus, self -adhered. Maximum Design Pressure=-97.5 osf: Deck: APA rated, 19/32 CAT, 0.578In., Exposure 1, OSB sheathing to meet project requirements Jurisdiction. Base Sheet: Elastobase (sand top surface) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggerec Underlayment: Elastoflex 6 TU or Elastoflex 56 G, applied in full mopping of hot asphalt. Maximum Design Pressure =-97.5 osf: , Deck: APA rated, 19/32 CAT, 0,578 in., Exposure 1, OSB sheathing to meet project requirements Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-Inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally solaced staggerec Underlayment: Polyflex G, torch -applied. Maximum Design Pressure =-105 osf: Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Havin Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap Or poly -Rim surface R Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-Inch o.c. at three (3) equally spaced staggere Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, ton NEMO ETC, I.I.C. Ceni(r#te o/Authodwtion#324SS 6- EDITION (2017) FBC NON-HVHZ EVALUATI Ot Polyglass Roof Undedayments, (954) 233-2230 ONEIVIOletc. o satisfaction of Authority Having ithe holes of the plate, parallel to d center rows. o satisfaction of Authority Having the holes of the plate, parallel to J center rows. (,Jurisdiction. diameter tin raps center rows. P FR, Polystick TU Max, Polystick o satisfaction of Authority Having center rows. P FR, Polystick TU Max, Polystick 0 satisfaction of Authority Having center rows. o satisfaction of Authority Having center rows. Jurisdiction. r torch -applied cap) J center rows. h-applied. Evaluation Report P32060.02.09-1125 FL5259-R29 Revision 25: 10/14/2019 Page 11 of 16 NNEMOletc. #42 Maximum Design Pressure = -105.0 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastabase or Mule -Hide Nail Base (poly -film top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to the width -direction of the sheet Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows. Primer: PG300 or ASTM D41 primer applied to stress plates. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #43 Maximum Design Pressure = -105.0 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sand tap surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to the width -direction of the sheet Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elasto0ex G TU or ElastoRex S6 G, applied in full mopping of hot asphalt. U44 Maximum Design Pressure=-105.0 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' Into the holes of the plate, parallel to the width -direction of the sheet Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Polyflex G, torch -applied. U45 Maximum Design Pressure = -112.5 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer at all tin -caps Base Ply: Polystick MTS Plus, self -adhered Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #46 Maximum Design Pressure =-120 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: OMG #12 Standard Roofgrip or OMG 414 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows. Underlayment: ElastoRex G TU or ElastoRex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #47 Maximum Design Pressure =-120 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface) Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-Inch o.c. at five (5) equally spaced staggered center rows. Underlayment: ElastoRex G TU or ElastaRex S6 G, applied In full mopping of hot asphalt. NEMO ETC, U.C. Evaluation Report P32060.02.09-RZ5 Cenifthrate ofAuthuri:otion a32J55 6" EDITION IZO171 FBC NON-HVHZ EVALUATION FL5259-R29 Polyglass Roof Underlayments; (954) 233-1230 Revision 25: 10/14/2019 Page 12 of 16 #48 Maximum Design Pressure = -127.5 psf: Nenno I etc. Deck: APA rated, 19/32 CAT, 0.578 In., Exposure 1, 058 sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole. Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional) Polystick MTS Plus, self -adhered. I Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SAP FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #49 Maximum Design Pressure=-127.5 psf: , Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. I Base Sheet: Elastobase (sand top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole. Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mapping of hot asphalt. i #50 Maximum Design Pressure = -127.5 psf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, O56 sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole. Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Polyflex G, torch -applied. 1 5.6.1.1 All other direct -deck, adhered Polyglass underlayment systems beneath foam -on the systems carry a Maximum Design Pressure of -45 psf. I I 5.6.1.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDS, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk' carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.7 Exposure Limitations: I TABLE 3: EXPOSURE LIMITATIONS Underlayment 'Maximum Exposure (days) Elastoflex G TU, HydraGuard Dual Pro, HydraGuard Tile Pro, Polystick MTS Plus, Polystick TU Max, Polystick TU P or Polystick TU Plus 180 Polystick IR-Xe or Polystick MU-X 0 90 Elastobase, Elastobase P, Polyglass G2 Base or Polyglass Base ' 30 180 Elastoflex S6 G, Elastoflex S6 G FR, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA -API Cap Sheet (for adhesive -set tile) UNLIMITED (FR), Polyflex G, Polyflex G FR, Polyflex SA P or Polyflex SA P FR (for mechanically fastened roof prepared roof covers) 5.8 Polystick MU-)( has been found through comparative testing to have a lesser coefficient of felt in a dry condition, tested at standard laboratory conditions. Agreement between pur Section 4.3, Note 1 of ASTM D1970-15, should be established as to slip resistance. i NEMO ETC, U.C. CeRhcate afAut#adrada.#32455 6- EDITION (2017) FBC NON-HVHZ EVALUATION Polyglass Roof Underlayments; (954) 233-1230 than ASTM D226 roofing and seller, as set forth in eport P32060.02.09-R25 FLSZS9-RZ9 Revision 25:10/14/2019 Page 13 of 16 NNEMOletc. 5.9 Tile Slippage Limitations (FRSA/TRI April 2012 (04-121): When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TAB LE 2: TILE SUPPAGE LIMITATIONS FOR DIRECFDECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope Elastoflex G TU Flat 10-tile stack 7:12 Lugged 8-tile stack (6 over 21 6:12 Elastoflex S6 G or S6 G FR Flat or Lugged 6-tile stack (4 over 2) 4:12 HydraGuard Tile Pro Flat or Lugged 6-tile stack (4 over 2) 7:12 Polyflex G or G FR Flat or Lugged 6-tile stack (4 over 2) 4:12 Polyflex SA P or SA P FR Flat or Lugged 6-tile stack (4 over 2) 4:12 Polystick MTS Plus Flat 6-tile stack (4 over 2) 5:12 Lugged 6-tile stack (4 over 2) 4:12 Polystick TU Max Flat 6-tile stack (4 over 2) or 10-tile stack 7:12 Lugged 6-[itestack(4over2) 7:12 Lugged 10-tile stack 6:12 Polystick TU P Flat 6-tile stack (4 over 2) 6:12 Lugged 6-tile stack (4 over 2) 4:12 Polystick TU Plus Flat or Lugged 6-tile stack (4 over 2) 7:12 Flat or Lugged 10-tile stack 6:12 6. INSTALLATION: 6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 Elastobase, Elastobase P or Mule -Hide Nail Base: 6.3.1 Non -Tile Applications: Shall be installed in compliance with the codified requirements for ASTM D226, Type II underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed and Polyglass published requirements. Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP, Polyflex SA P FR, Mule - Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered, Elastoflex G TU, Elastoflex 56 G or Elastoflex 56 G FR in hot asphalt or Polyflex G or Polyflex G FR, torch applied. Roof cover limitations are those are those associated with the top -layer underlayment, as set forth in Table 1. 6.3.2 Tile Applications: Elastobase, Elastobase P or Mule -Hide Nail Base are limited to use as a mechanically attached base sheet in the "Two Ply System" from FRSA/TRI April 2012 (04-12). Reference is made to Table 1 and Section 5.6.1 herein, coupled with FRSA/TRI April 2012 (04-12) Installation Manual. NEMO ETC, U.C. Evaluation Report P12060.02.09-R25 Cenifrcare 0Aurhado6oa 02455 6- EDIT] ON (2017) FBC NON-HVHZ EVALUATION FL5259-R29 Polyglass Roof Underlayments; (954) 233-1230 Revision 25: 10/14/2019 Page 14 of 16 • �J 6.4 HydraGuard Dual Pro, HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide S Polyflex SA P FR, Polystick IR-Xe, Polystick MTS Plus, Polystick MU-X, Polystick TU Max, 6.4.1 General: All seal -lap seams (selvage laps) must be firmly rolled with a in accordance with Polyglass requirements to ensure full contact and adhesion. For HydraGuard Dual Pro and HydraGuard Tile Pro, align the edgeofthe top sheet to the end of the glue pattern (the sheet will overlap the fabric). View of Ovelap Seam of HydraGuard 6.4.2 Non -Tile Applications: Shall be installed in compliance with the codified requirements for ASTM D1970 (except Polys Table 1507.1.1 for the type of prepared roof covering to be installed and Polyglass published r( 6.4.3 Tile Applications /excludes HydraGuard Dual Pro, Polystick 1R-Xe and Polystick MU-X): Shall be installed in compliance with the requirements for Self -Adhered Membrane set forth in Polyglass published requirements. For mechanically fastened the roofing over 2-ply system, consisting of Base Sheet and self -ad fastening shall be not less than FRSA/TRI April 2012 (04-12), Table 1. For adhesive -set tile applications, refer to Section 5.6.1 herein. 6.4.4 Multi-PlyUnderlavment Systems: Polystick MTS Plus followed by HydraGuard Tile Pro, Polyflex SA P, Polystick MTS Plus, Poll Polystick TU P or Polystick TU Plus is allowable for use under mechanically attached prepared those associated with the top -layer material. This is not a requirement, but is'allowable if t desired. I Polystick MTS Plus followed by HydraGuard Tile Pro, Polyflex SA P, Polystick Tl) Max, Polysti allowable for use under adhesive -set tile systems. Limits of use are those associated with the requirement, but is allowable if a 2-ply underlayment system is desired. 6.5 6.5.1 Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR: f Elastoflex GTU, Elastoflex S6 G or Elastoflex56 G FR shall be installed in compliance with current requirements. For use in tile applications: ✓ Elastoflex GTU is for use as an alternate to "Mineral Surface Roll Roofing" (AST M D6380, Cla from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the H in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or ✓ Elastoflex S6 G is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Cla, from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the H in the'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened of ✓ Elastoflex 56 G FR is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D63 System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened the roof systems I Sheet" in the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fast �MU Sheet (FR), Polyflex SA P, U P or Polystick TU Plus: Pro and HydraGuard Tile Pro TU P) underlayment in FBC April 2012 (04-12) and top sheet(s), Base Sheet MU-X, Polystick TU Max, systems. Limits of use are ly underlayment system is TU P or Polystick TU Plus is -layer material. This is not a published installation M) in the "Single Ply System" Asphalt applied "Cap Sheet" dhered tile roof systems. M) in the "Single Ply System" Asphalt applied "Cap Sheet" dhered'tile roof systems. I, Class M) in the "Single Ply the Hot Asphalt applied "Cap ed the roof systems. NEMO ETC, I.I.C. i Evaluation Report P12060.02.09-R25 Certifmre o(Authonzatlen 032455 6- EDITION (2017) FBC NON.HVHZ EVALUATION FL5259-RZ9 Polyglass Roof Underlayments; (954) 233-1230 Revision 25:10/14/2019 Page 15 of 16 NNEMOjetc. 6.5.2 For hot -asphalt -applications, Elastoflex GTU, El a stoflexS6G or Elastoflex S6 G FR shall be fully asphalt -applied to the substrates noted in Table 2. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, off -set minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge. 6.6 I Polyflex G or Polyflex G FR: 6.6.1 Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements. For use in the applications: ✓ Polyflex G is for use as an alternate to the Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04- 12) beneath mechanically fastened or adhered tile roof systems (Refer to Table 2 for base sheet options). ✓ Polyflex G FR is for use as an alternate to the Heat Applied "Cap Sheet' in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems (Refer to Table 2 for base sheet options). 6.6.2 Polyflex G or Polyflex G FR shall be fully torch -applied to the substrates noted in Table 2. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, off -set minimum 3 feet from course to course. Side and end laps shall be fully heat -welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge. 6.7 Tile Staging: 6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Table 2 herein, and Polyglass published requirements for tile staging. 6.7.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRI April 2012 (04-12) must be used on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or nail -boards, to prevent the sliding and/or damage to the underlayment during the loading process. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. 6113203 QA requirements. Refer to Section 4 herein for product & production locations having met codified physical properties specifications. 9. QUALITY ASSURANCE ENTITY: UL, LLC—QUA9625; (314) 578-3406; k.chancellor@us.ul.com - END OF EVALUATION REPORT - NEMO ETC, I.I.C. Evaluation Report P32060.02.09-R25 Certifimte ofAuthorimtion #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FLSZ59-RZ9 Polyglass Roof Underlayments; (954) 233-1230 Revision 25: 10/14/2019 Page 16 of 16