Mr. William P. Platts
3640 North Milton Road
Ft. Pierce, FL 34946
-r
COMMUNITY
DEVELOPMENT
ADMINISTRATOR
TERRY L. VIRTA, AICP,
Subject: First Presbyterian Church, Major Adjustment to a Minor Site Plan
Dear Mr. Platts:
The St. Lucie County Development Review Committee has reviewed your April 28,
1994, application for a major adjustment to the above referenced project and have
determined it to meet the minimum technical requirements of Section 11.02.03(D) of the St. _
Lucie County"Land Development Code. The purpose of this adjustment is to add a 2,635
square foot administration building.
This approval does not in any. way constitute authorization to begin construction.
Prior to the commencement of any construction on this property an application for specific
building permits _must be obtained from this department. Building permit applications must
be made at any time following the receipt of this notice. For specific information on the
composition of these submissions, including applicable fees, please contact the St. Lucie
County Building Inspection section.
If you have any additional questions please contact Hank Flores at 407/468-1576.
Sin ly,
f
avid P. Kelly
Planner III
hf
cc: County Engineer
:Fire. Marshall
File
HAVERT L. FENN, District No. 1 -.JUDY CULPEPPER. District No. 2 - DENNY GREEN: District No. 3 - R. DALE TREFELNER, District No. 4 - CLIFF BARNES, Disrrict No. 5
2300 Virginia Avenue - Forr Pierce, FL 34982-5652
Administrator: (407) 468-1590 - Growth Management: (407) 468-1553 Planning: (407) 468-.157b
Codes'Complionce: (407) 468-1571
ST LUCIE COUNTY
CERTIFICATE OF CAPACITY
'CERTIFICATE NO.:C94-093
This document certifies that concurrency will be met and that adequate public
facility capacity exists to maintain the standards for levels of service as
adopted in the St. Lucie County Comprehensive Plan for:
1. TYPE OF DEVELOPMENT ORDER: MINOR SITE PLAN
. OF UNITS: N/A, NO. OF SQUARE FEET: 2,635
2`. -OROPERTY LEGAL DESCRIPTION & TAX I.D.# (& STREET ADDRESS):
-332-0001-000/2 FIRST PRESBYTERIAN CHURCH
1780 HARTMAN RD ADMINISTRATION BUILDING
3. APPROVAL #: LETTER: 05/02/94
4. SUBJECT TO THE FOLLOWING CONDITIONS FOR CONCURRENCY:
NONE
S. OWNER'S NAME: FIRST PRESBYTERIAN CHURCH
ADDRESS: 1780 HARTMAN RD
FT PIERCE, FL 34947
6. CERTIFICATE EXPIRATION DATE: 05-02-95
This certificate of capacity is transferable only to subsequent owners of the
same parcel, and is subject to the same terms, conditions, and expiration date
f. as listed herein. The expiration date can be extended only under the same
., terms and conditions as the underlying development order issued with this
r certificate, or for subsequent development order(s) issued for -the same
p. property, use and size as described herein.
3< <
SIGNED: DATE: April 29, 1994
Community velopment Administrator
ST. LUCIE COUNTY, FLORIDA
i.
i
1.
B.-
BOARD OF COUNTY
COMMISSIONERS
May 2, 1994
Mr. William P. Platts
3640 North Milton Road
Ft. Pierce, FL 34946
-< COMMUNITY
• ����� DEVELOPMENT
��OR1�P ADMINISTRATOR
TERRY L. VIRTA, AICP
Subject: First Presbyterian Church, Major Adjustment to a Minor Site Plan
Dear Mr. Platts:
The'St. Lucie County Development Review Committee has reviewed your April 28,
1994, application for a major adjustment to the above referenced project and have
determined it to meet the minimum technical requirements of Section 11.02.03(D) of the St.
Lucie, County Land Development Code. The purpose of this adjustment is to add a 2,635
square foot administration building.
This approval does not in any way constitute authorization to begin construction.
Prior to the commencement of any construction on this property an application" for specific
building permits must be obtained from this department. Building permit applications must
be made at any time following the receipt of this notice. For specific information on the
composition of these submissions, including applicable fees, please contact the St. Lucie
County Building Inspection section.
If you have any additional questions please contact Hank Flores at 407/468-1576.
Sin"ly,
avid P. Kelly
Planner III
hf
cc: County Engineer
Fire Marshall
File
HAVERT L. FENN, Disrriu No. 1 JUDY CULPEPPER, District No. 2 DENNY GREEN, District No. 3 R. DALE TREFELNER, District No. 4 CLIFF BARNES, District �
2300 Virginia Avenue • Fort Pierce, FL 34982-5652
Administrator: (407) 468-1590 • Growth Management: (407) 468-1553 • Planning: (407) 468-1576
Codes Compliance: (407) 468-1571 \
J
' �rarxo� ' a�tsnoo Hlonz • ss
sogpr4s qua�doTaea Agiunm=o:
V66T 6Z TT-T
•uTaaaq pagzaosap sp azzs pup asn 'Agaadoad
ampsagq ion panssz (s).7ap.10 quamdoTanap quanbasgns ao3 ao 'agpot�rgaao
sTgq ggTM ponssi zapso quamdoTanap buTATzapun aqq sE suoTgTpuoo pup s=aq
amps aqq aapun ATuo papuagxa aq upo agpp UdTgvaTdxa aqy •uTaaaq pagsTT sp
agpp uoTgpzTdxa pup 'suoigTpuoo 'suaaq ames aqq oq goelgns sT pup 'Tap-Md alres
"'auq go s:rauMo quanbasgns oq ATuo aTgpaa;supaq sz AgTapdpo go 9gpaT9Tja9D szgy
96-ZO-SO :Hlda NOIlvHId%H alvoiall-SHO •9
LV 6V E Ua RDUaId la
all NVNtLUVR O 8 L T : sssuaav
HDUnHo NKI2i211ASsaacl SSHIa : MMK S' Ham0 • S
HNON
AOiQMMOROO Hoa SNOIIICEN03 XIMOMOa HHZ OZ 1031'anS • t
fii6/Z0/S0 :11911H'I # ' VAOddd[V E
JNIa'IIIIa MOISvRisSINIwax a2I .NKWJjHVH" 08LT
HOMHO NVIUHSASSHHa ZSHIa Z/000-T000-ZEE-LTVZ
: (ssauaav aHHxss V) # • a • I XVI I xolsalxosaa 'IKJH'i, A-M.Mzdoud • z
S£9 ZZ :SHH3 mmflas aO -ON 'b'/N :SSIKn jo •oid
NK'Id HSI S HOMIW : HaC[HO SNaKdO'IH4Ha aO Hdxs • T
:ioj up -Ea aeTsuag9idmo3 AqunoD atones •qs aqq uT pagdopp
sp aotAias 10 918AGI 201 sPiepupgs aqq uTU4UTUM oq sgspca AgTopdEo AgTTzoEg
a-rTgnd agenbape gEgq Pup gaui aq TTTA Aouaunouoo gpgg saTJTgiao quaunoop srgsl
£60-V6O: •OH HSKOIaIMURD.
A[SIOVd[VD 30 HIVOIaIS2iHO
asrinoo Hlona is
0
WILLIAM P: -PLATT3 - ARCHITECT
ROBERT TERRY JR. - ARCHITECT
" 3640 NORTH MILTON ROAD, FT., PIERCE, FLORIDA, 34946, 407-461-3311.
First Presbyterian Administration Building
1780 Hartman Road
Ft. Pierce, FL,
Page 1 - Addendum#1 - April 15,1994
-T-his.-addendum-hereby becomes a part of the Plans and Specifications and shall
be -incorporated in the -Contract Documents.
1) Paint Schedule: Equal to Pittsburgh
a) Interior Walls - (low luster)
1 coat PPG 6-2 -Latex-Primer - Sealer
1 coat PPG 6411 Latex Eggshell
b) Bathrooms
1 coat PPG 6-2 Latex Primer Sealer
2 coats PPG-6-51.0 Latex.S/G�Enamel
c) Interior Doors, Wbod=T-r-im-and=Base_
1 coat PPG 77-302 Oil Stain Fruitwood
1 coat PPG.77-30 Sand -Sealer.
2 coats PPG 774 Gloss Varnish
d) Exteri&`Stubbo
1 coat -Pigmented -Primer Surfacer#39294
1 coat 4-110-Elastomeric
Color to match -existing Fellowship Hall
e) Fascia and Walkway Beams =
1 coat -PPG 1-870 Oil Primer
1 coat PPG 77 860 'series to -match existing Fellowship Hall
f) Soffit arid Walkway Ceiling. "
1 coat PPG -semi-transparent wood stain 77860 series
Color to match existing Fellowship Hall -
g) -Steel Columns-
1 c6at-PPG-primer,*97 4582
1 coat Industrial Enamel G-282. series
Page 2 - Addendum #1 - April 15, 1994
2) Stain Glass. Stain Glass in Hallway is to be installed by Owner. General
Contractor is to verify size of opening and provide finish trim.
3) Walkway Roofing. 3x6 Double T&G Douglas Fir must be kiln dried. Kiln
dried 3x8 Double T&G Ponderosa Pine is an acceptable substitute.
4) Anderson Windows. Do not provide extension jambs on Anderson Windows.
Windows are to be placed flush with interior drywall as shown on Detail #1.
Provide 2 1/4" Colonial Trim around window. Interior of window is to be stained
to match trim.
DETAIL #1.
� If.IC�ty
J
Page 3 -Addenclum #1 -April 15, 1994
5) Water and Sewer Lines. Existing water and sewer lines run from Hartman
Road along the South side of the entry road, then running North along a line
parallel -to -the Parking Lot. Se& -Detail #2.
DETAIL #2
I
W
a
4 "-to
ss
Page 4 -Addendum #1 -April 15, 1994
6) Plumbing Riser and Plan. Reverse Plumbing Riser Diagram and Plan as
shown in Detail #3.
DETAIL #3 /1
GO
3
n c'lIx
Z�l
IPA* Z11
L Wiz"
Zl�
bclG
�I
4" 411 411
rs
l~-I
PLAN
�_:L4L
tklG
William P. Platts -Architect
Robert Terry, Jr. - Architect
3640 North Milton Road, Ft. Pierce, FL, 34946
June 13, 1994
Paul Jacquin & Son, Inc.
P.O. Box 4343
Ft. Pierce, FL, 34948-4343
Re: First Presbyterian Administration Building
Dear Paul:
The Contractor may use 3000 psi Fiber -mix concrete with 1.5 lbs. per cubic yard of 100%
virgin polypropylene in place of 3000 psi concrete over 6x6, 10/10 W.W.F.
Sincerely,
Wil ' Pla
Robert Terry, J .
s
FOR OFFICE USE ONLY
REQUIRED
VEGETATION
f
]
ENVIRONMENTAL
E
]
PLANNING/SITE PLAN
F
�
CODE ENFORCEMENT
USA
I
]
TAZ
]
WATER SUPPLIER
SEWER SUPPLIER-
f
]
DER CERTIFICATION
(
]
FL DNR (CCCL),
j
FL DOT
]
SLC STORMWATER PER
j
]
MANGROVE ALT
(
]
SEA TURTLE PROT
(
I
PR* 476o(>
DATE RECEIVED NOT REQUIRED
REQUIRED FEES
BP VALUE l55_ D00,
PLANS -REVIEW FEE $ !Jo RADON FEE
_C OF C FEEQ
ROAD IMPACT FEE $ .
ROAD IMPACT DISTRICT ROAD PO
_ ROAD -IMPACT CREDIT-_,. YFS j I NO
ALTERNATE DEV FEE $ ALT_ DE.V_ FEE ZO G
SCHOOL IMPACT FEE $ ' ! V SCHOOL IMPACT
SCHOOL BOARD APPROVEDCTIF="DfT
POLICE' IMPACT FEE $ EXEMPTION YES j ] NO
FIRE IMPACT FEE $
SUB PERMTI'S REQUIRED - NOT REQUIRED
GAS ] [
AIR CONDITIONING T�
ELECTRIC I
PLUMBING t ]
SCREEN ENCL/FENCE I E I
ROOF
DRIVEWAY ] [ ]/
f
j]NOj]
/ ZONING CHECKS
V BBL LOT COVERAGE
GE EASEMENT LOT SPUTS)
- A'FFIDAVIT FOR RELIGIOUS FACILITY G
.,
STATE=';OF FLORIDA
COUNTY OF ST. LUCIE
BEFORE MZI, the undersigned authority, personally appeared
Ah-A, �Kic , who be duly sworn deposes and says:
1. Affiant is t1 o:z 1 ft" k'
.2. As a representative and agent of >E
0ma
he says thatF_jjg�
rtI&AK (2�luam
will not presently house a school or day care facility, and
that, if at some point in the future the
1 should decide to house a school or
day care facility, the -(�S�" �(����uem
will voluntarily pay a road impact fee appropriate for that
use, according to the most current Road Impact Fee Ordinance
fee schedule.
3. Affiant understands that St. Lucie County is relying on the
statements made in the Affidavit in determining whether to
issue a building permit without,.j�ayment of a road impact fee.
STATE OF FLORIDA, COUNTY OF
The foregoring instrument was acknowledged before me this'Iday
Of , 19-TL, by _�mn eg, who is personally
known to me or who has produced as identification.
Marsha -
Signature of Notary Type of Print Name of Notary
Notary Public Title U,0590 L Commission Number
(seal)
EE�
MARSHA G. PETERSON
.MY COMMISSION # CC 295911
EXPIRES: June 20.1997
Bonded Thor Notary Public Undewlters
BUILDING PLAN CHECK
ST. LUCIE COUNTY -FORT PIERCE FIRE PREVENTION BUREAU
FORT PIERCE, FLORIDA
TELEPHONE 407-467-2312
FAX 407-467-2325
.;J'URISDICTION:
St. Lucie County PLAN NUMBER
#6390
` PROJECT NAME:
FIRST PRESBYTERIAN CHURCH BUILDING DEPT. NO.
PR 40766
. ` CONTRACTOR:
Paul Jacquin PHONE NUMBER
465-2475
ARCHITECT: __
Robert Terry Jr. PHONE NUMBER
461-3311
OWNER:
First Presbyterian Church DATE RECEIVED
5-16-94
LOCATION:
1780 Hartman Rd.
5-16-94
BUILDING SIZE:
2518 sq. ft. NUMBER OF STORIES
1
OCCUPANCY TYPE:
Business BUILDING HEIGHT
' CONSTRUCTION TYPE: SBCCI. V Un.
'
NFPA. III (200)
` IRE PROTECTION:
Automatic Sprinkler Yes No X
Occupancy Hazard N.F.P.A. #13
Requirements:
1. Provide an approved illuminated exit sign as shown in red.
2: Provide a 2A-10BC rated fire extinguisher for each 75' of travel.
3. Draftstopping shall be provided in wood frame construction and shall be required in attic
spaces so that horizontal areas do not exceed 3000 square feet.
Draftstopping materials shall be not less than 1/2" gypsum board or 1/2" plywood,
adequately supported.
1.4. We -recommend an emergency lighting system for the corridor and at each exterior exit.
CONTRACTORS RESPONSIBILITY TO NOTIFY BUREAU ON ALL INSPECTIONS
jHOUR NOTICE, REQUIRED ON ALL INSPECTIONS
REVIEWED BY:
DATE
Sheet No, / of
Coln anent
PerfNrmance Method for
Commercial Buildings Form 40UB-94
ENERGY EFFICIENCY CODE
FOR BUILDING
CONSTRUCTION
Florida Department
of Community
Affairs
FLA/COX-94
Version 2.1
PROJECT NAME_FIRST PRESBYTERIAN ADDITION
PERMITTING OFFICE:
ADDRESS:
LAKEWOOD PARK_____ _
ST. LUCIE COUNTY
CLIMATE ZONE: 6
- OWNER: _FIRST PRESBYTERIAN CHURCH_ PERMIT NO: 00-94-0000
JURISDICTION NO: 661000
Y
U I LD I NG TYPE: _Pre'schoo l /E 1 .
s:CONSTRUCTION CONDITION: New.construction
�-DESIGN..GOMPLETION: _Finished Building_____—___
CONDITIONED�FLOOR AREA: 2550 NUMBER OF ZONES:'-1
MAX. TONNAGE OF EQUIPMENT PER -SYSTEM:
'COMPLIANCE CALCULATION:
METHOD B
DESIGN
CRITERIA
RESULT'
ENVEhOPE_ "PERFORMANCE
51.35
73.00
PASSES .
OTHER ENVELOPE REQUIREMENTS
PASSES;
HVAL •: EQU.I PMENT
I NG . EQU I PMENT
r,Mr�rr,Ci'OL
.. 1 . SEER
10.00
10. 00
PASSES
HEATING EQUIPMENT
l- -Et
1.00
N/A
AIR DISTRIBUTION SYSTEM INSULATION
LEVEL
1. :Ventilated
6.00
6.00.
PASSES,
WATER HEATING EQUIPMENT
1.' EF ..
0.88
0.88
PASSES
PIPING INSULATION REQUIREMENTS
1-.,Non-Circulating
-----------------------------------------------------------------------
0.50
0.40
PASSES
COMPLIANCE CERTIFICATION:
I hereby•certify that the plans and
specifications covered by this calcu-
lation are in compliance with the
Flo rida.Energy'Efficiency Code.
PREPARED BY:
- --- ----- ----
DATE: •
Review of the plans and specifica
tions covered by this calculation,.
indicates compliance with the
Florida Energy Efficiency Code.
Before construction is completed,,
this building,will be inspected
for compliance in accordance with
I hereby certify that this building is Section 553.908, Florida Statutes.'
in compliance with the Florida Energy BUILDING OFFICIAL:
Efficiency Code. DATE: -------- --
------------------------
OWNER/AGENT:
. DATE: .------------------------
--=;---------------------------
.'IRthdii""eby, certify, <*> that the system design is in compliance with the Florida
E ergy,.Eff.iciency Code.
SYSTEM DESIGNER REGISTRATION/ST TE
ARCHITECT
MECHANICAL:PLUMB ING 4_913_Oleander Ave.
ELECTRICAL: Y -FT. RERCE, FL 34982-- --- ------------------
NG
�E�W>:, '-----------------------------------------------------=—
F *> Signature is required where Flori a law requires design to be erformed-
byy.registered design professionals. Typednames and registration numbers may
.be used -where all relevant information is contained on signed/sealed plans.
---------------------------------------------------------------------------
4 .. BUILDING INFORMATION COMPLIANCE
CHECK'
401.=7--7-GLAZING--ZONE 1----------------------------------------------- -v.-
Elevation Type U SC VLT Shading Area(Sgft)
-Northeast Commercial 1.1 0.92 Continuous Ove 60
Southeast Commercial 1.1 0.92 Continuous Ove 32
Southwest Commercial 1.1 0.92 Continuous Ove 40
Northwest Commercial 1.1 0.92 Continuous Ove 45
Total Glass Area in Zone 1 = 177
Total Glass Area = 177
402.------WALLS--ZONE 1------------------------------------------------ ---
Elevation Type U Added R Gross(Sgft)
.Q-------=--------------------------------- ----- ------- -----------
Northeast 8" BLOCK + INSULATION .07 0 376
Southeast 8" BLOCK + INSULATION .07 0 464
Southwest 8" BLOCK + INSULATION .07 0 440
Northwest 8" BLOCK + - INSULATION .07 0 0
Total Wall Area in Zone 1 = " 1280
Total Gross Wall Area = 1280
,403.---7---DOORS--ZONE 1------------------------------------------------ ---
Elevation, Type U Area(Sgft)
0 0
Total Door Area in Zone 1 = 0
y Total Door Area = 0
404.----_--ROOFS--ZONE 1------ ------------------------------------------ ;
Type Color U Added R Area(Sgft)
------------------------------------ ------ ----- ------- ----------
TRUSSES W/ DRYWALL CLG.-R-30 Medium 0.03 2550
Total Roof Area in Zone 1 = 2550
Total Roof Area 2550
405.------FLOORS-ZONE 1------------------------------------------------ ---
Type. R Area (Sgf.t )
Slab on Grade%Uninsulated 0 2500
Total Floor Area in Zone '1 = 2500
Total Floor Area = 2500
406.------INFILTRATION -------------------------------------------------- ---
I CHECK
Infiltration Criteria in 406.1.ABC.1 have been met..
i 407.- ----- COOLING SYSTEMS----------------------------------------------- ---
Type No Efficiency IPLV Tons
--------------------------- ------------- -------------------
1. Split System 2 10.0 Q 4.00
Ift 408.------HEATING SYSTEMS----------------------------------------------- ----
. Type No Efficiency BTU/hr
1. Electric Resistance 2 1.0 10000
. 409.------VENTILATION --------------------------------------------------- -----
CHECK
•• Ventilation Criteria in 409.1,ABC.1 have been met.
410.-=---'AIR DISTRIBUTION SYSTEM---------------------------------------- ---
AHU Type Duct Location R-value
a-----------------------------------
�l. Split / PTAC Air Conditioner Ventilated 6.0
411.7-7 --- PUMPS AND PIPING -ZONE 1--------------------------------------- ---
Type R-value/in Diameter Thickness
------------=--------------------------------------
1. Non -Circulating 5 .75 0.5
12. ---WATER HEATING SYSTEMS -ZONE 1----------------------------------
-Type Efficiency StandbyLoss InputRate Gallons
-------------------------------------------------------
1. <=12 .kW 0.878 0 4.5 40
413.-----ELECTRICAL POWER DISTRIBUTION ----------------- =---------------- ----
CHECK
Metering .criteria in 413. 1. ABC. 1 have been met,
Transformer. criteria in 413. 1. ABC. 2 have been met.
414.---'-MOTORS--------------------------------------------------- ----- -----
Motor efficiencies in 414.1.ABC.1 have been met.
415.----=LIGHTING SYSTEMS -ZONE 1--------------------------------------- ---
•Space Type No Control Type 1 No .Control Type 2 No Watts Area(Sgft)
„-------- =---------------
Classroom/ 1 On/Off 10 0 4600 2550
*r Total Watts for Zone 1 = 4600
Total Area for Zone 1 = 2550
Total'Watts = 4600
Total Area = 2550
CHECK
Lighting criteria in 415.1.ABC have been met.
--------------------------------- ----- -
16, HVAC load sizing has been performed. (407.1.ABC.1)
------------------------------ ----- --.
17. Z7uct siting and design have been performed. (410. 1. ABC. 1. 2)
---------------------------------------'---
18. Testing and balancing will be performed. (410.1.ABC.4)
------------------------------------
-------------------------- ---
19. Operation%maintenance manual will be provided to owner.(102.1)
------------------------------------------------------------------------
P
PROJECT TITLE
FIRST PRESBYTERIAN
ADDITION
BUILDING TYPE
Preschool/El.
BUILDING LOCATION :
ST. LUCIE COUNTY
f.
BUILDING AREACft2>:
2550
.BUILDING ;ENVELOPE COMPONENT PERFORMANCE
WALL ORIENTATION
WEIGHTED
m N NE
E SE N.
SW W
NW AVER. CRITERIA
WALL
376
464
440
0.14
:0.278
GL
60
32
40
WWR
WWR`
s Sc
0.920
0.920
0.920
0.92
0.500
PF
0.33
0.33
0.33
0.33
0.00.
VLT
0,00
0.00
0.00
0100
IAA ',"
Uof
1.100
1.100
1.100
1.10
1. 150
W Up
0.07
0. 07
0. 07
0.07
0.371
HC
6.58
6.58
6.58
6.58
1
-IP
3
3
3
3
N/A
'
L O A D S
TOTAL
HEAT
0.315
0 . 266
0.262
0. 843 <
3.2 16 .
COOL
16.429
17.190
16.881
50.503<
69.784
f SUM -
16.744
17.456
17.146
51.346<
73.000
K K K%k PASSES
OTHER ENVELOPE REQUIREMENTS
MAXIMUM PERCENTAGE OF
ROOF AREA IN SKYLIGHTS:
DESIGN
LIMIT
Percentage of -Roof Area in Skylights
0.000 =
0.0000
MAXIMUM ALLOWABLE Up:
Roof
0.030 <
0.0990
PASSES*.
e
PROJECT TITLE FIRST PRESBYTERIAN ADDITION
BUILDING TYPE Preschool/El.
jBUILDING LOCATION ST. LUCIE COUNTY
BUILDING AREACft2>.: 2550
SYSTEM -PERFORMANCE CRITERIA
BUILDING DESIGN
Interior Lighting Power 4600 W 1.80 'W/Gross ft2
,Exter-ior Lighting Power 0 W
°INTERIOR LIGHTING CRITERIA:
Space No.
Type',�Area CIS Ht Spaces AF UPI) PE LPB Total LPB
• �e I
3 2550.0 8.0 1 I 1.01 2.00 2.02 5148 5148
Unit -Power Density 2.02 W/Gross ft2
.Interior Lighting Power Allowance 5148 W
PASSES
EXTERIOR LIGHTING CRITERIA:
AREA. AREA AREA OR ALLOWANCE
CODE., DESCRIPTION LENGTH WATTS
Exterior Lighting Power Allowance 0.00 W
******** PASSES ****K***
THE hIGHTING SYSTEM CONTROL REQUIREMENTS:
TOTAL EQUIVALENT
SPACE NO. CONTROLS CONTROL POINTS
NO. DESCRIPTION AREA TASKS TYPE 1 NO. TYPE 2 NO. INSTLD. REQD.'.-
3 Classroom/ 2550.0 1 On/Off 10 0 10 > 3
*%K****** PASSES ********
n �
PROJECT TITLE FIRST PRESBYTERIAN ADDITION
BUILDING, TYPE Preschool/El.
t BUILDING-:LOCAT I ON ST . LUC I E COUNTY
BUILDING AREA<ft2>: 2550
v
HVAC SYSTEMS PERFORMANCE:
Cooling System
. Type
Measure
#1 #2
Minim.
#1
Minim,
#2
System
Eff. #1
System-
Eff. #2
Result
for #1
Result.
for #2
Split Sys:
SEER
10.00
0.00
10.00
0.00
PASSES
Heating System
&A
Measure
Minimum Req.
Efficiency
Result
Ele. Resis.'
Et
1.00
NIA
PASSES ****
AIR DISTRIBUTION SYSTEM INSULATION LEVELS:
Zone # Duct Location Minimum R-Value
1. Ventilated 6.00
*:* PASSES K K**
9
PROJECT TITLE FIRST PRESBYTERIAN ADDITION
BUILDING TYPE Preschool/El.
BUILDING LOCATION' ST. LUCIE COUNTY
BUILDING AREA Cft2> : 2550
WATER HEATING SYSTEMS PRESCRIPTIVE CRITERIA
Design R-Value
(5.100
Result
PASSES
System.
Type
Measure
Minimum
EF / Et
Maximum
SL
Design
EF / Et
Design
SL
Result
Electric <= 12kW
EF
0.877
0.000
0.878
0'.000
PASSES
PASSES
PIPING INSULATION REQUIREMENTS:
Pipe Insulation Thicknass<in>
System Type
O.D.Cin>
Minimum Req.
Design
Result
Non -Circulating
0.75
0.40
0.50
PASSES-
:k K PASSES