Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SUBMITTED PAPERS
OFFICE USE ONLY: Dater _00 �l Fee Due: _� Receipt# Permit # �� %off _ w a ALL INFO MUST BE COMPLETE & FILLED IN TO BE ACCEPTED St. Lucie County Building and Zoning SC 2300 Virginia Avenue gNNE� Ft. Pierce,772 6 1553 -5652 St '� �C(e c©U my APPLICATION FOR ALUMINUM STRUCTURES PERMIT PROJECT INFORMATION 1. LOCATION/SITE ADDRESS: 95C) S -Tnd.1an 'Foie-- —twl Vve- 2. PROJECT NAME: ('hcV�e—+ — SITE PLAN NAME: 3. PROPERTY TAX ID #: 4. LEGAL DESCRIPTION (attach extra sheets if necessary): Li ( b� S 6 31 ft CE SeG tcf LV6 EE QV EEC RZP, aruA d IDnjp+ o- 553 t -f�-6� { 5. PAT 2� 6. PAGE 7. BLOCK 8. LOT BOOK NO. NO. NO. 9. PARCEL SIZE: ACRES/SQ FT. • 52.4qG LOT DIMENSIONS I t U x 4 l V 10. SETBACKS (ACTUAL) FRONT: BACK: RIGHT SIDE: LEFT SIDE: 11. TYPE OF STRUCTURE (CHECK ALL APPROPRIATE BOXES FOR EACH AND EVERY TYPE OF STRUCTURE) TYPE OF CONSTRUCTION ❑ SCREEN ROOM �I CARPORT/PATIO ROOF ❑ HABITABLE GLASS ROOM ❑ SUNROOM ❑ SHED, POOL ENCLOSURE ❑ M H ROOF OVER ❑ ROOF SYSTEM OVER N=New A= Addition R = Rebuild SG = Slab on Grade SR = Raised Slab WD = Wood Deck ❑ NEW ❑ EXISTING ❑ NEW 14 EXISTING El. NEW ❑ EXISTING ❑ NEW ❑ EXISTING ❑ NEW ❑ EXISTING ❑ NEW X EXISTING - ❑ NEW ❑ EXISTING ❑ NEW ❑ EXISTING DIMENSIONS I SQUARE FEET OF CONSTRUCTION `1 3! O X X X L ti•X rl11 X ��� `4 ❑ -OTHER. I I ❑ NEW ❑ EXISTING X ❑ POOL FENCE I I Linear feet TOTAL SQUARE FOOTAGE OF CONSTRUCTION LI- 12. VALUE OF CONSTRUCTION: $ 161000 The value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction activities. If the value is $2500 or more, a RECORDED Notice of Commencement must be submitted PRIOR TO FIRST INSPECTION. SLCCDV Form No.: 001-02 Rev. 31112009 OWNER INFORMATION NAME: ADDRE CITY: _ PHONE (DAYTIME): (M ZD9 - 0:3 E? EMAIL: _ FILL IN NAME AND ADDRESS BELOW IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE: FEE SIMPLE TITLEHOLDER: ADDRESS: CITY: PHONE (DAYTIME): (—J CONTRACTOR INFORMATION STATE: STATE OF FLORIDA REGJCERT #: C(aC 201 * 93 ST. LUCIE COUNTY CERT #: ZZ rq 3 a BUSINESS NAME: '•�. `S- tT�.ns4t m i nt) m Sarvi e-C, LLL Aa -rhe Pnr6i rGiC42 ru QUALIFIER'S NAME: ADDRESS: _ 1) Ka ri6I/1 Qlaie. CITY: STATE: 16'7L= ZIP - 3 q-/ PHONE(DAYTIIVIE): ( j4(915-(0222 FAX NO. �RA5-325'.- email: otdmt!1A -hCD=haxkr4- ARCHITECT/BNGINEER: ADDRESS: I .✓�X%' CITY: ��Ffi-A t'�Gi? STATE: ZIP PHONE (DAYTIME): ( ;2,2-4-7°74 NOTE: IF APPLICABLE, SUBCONTRACTOR AGREEMENTS MUST BE ATTACHED TO APPLICATION FOR ROOFING, ELECTRIC, PLUMBING, AND HVAC ZONING REQUIREMENTS yy�1� All su h structures will be subject to the requirements of the ST. LUCIE COUNTY LAND DEVELOPMENT CODE. 2 scaled plot plans showing lot size, dimensions of existing host structure, and proposed aluminum addition. All setbacks including front, side; rear and Aistance between adjacent property structures in MH Parks shall be indicated on the plot plan. ❑ 2 sets of color photos for all storm damaged areas to be reconstructed. One picture must include house address number -for inspection verification. ( not required for construction unrelated to storms) Q'C SECTION QI TOWNSHIP 7� RANGE1 v V MAP NO. 12'� V 1 �I ZONING I �� I LAUSE I �j� I LOT CVG % I I P rmitsII� ND XwgULLCU REPORT CODE BIMS FEE $ MSC FEES $ TOTAL FEES $ T y3i,. ...,. �.i.li✓y`? if ., 1 FRONT REVIEW COUNTER !R WMa.C{....3..i.. ,,. .�.., ..... _ � PLANS ZONING SUPERVISOR EXAMINER , ... � ... .. .> .�. .,...^... VALUE OF CONSTRUCTION VEGETATION USING ICC TABLE nArM 11741(( PLAN IIEVrj�W SPECIFICATION CHE��ST PLEASE PROVIDE ONE OF THE FOLLOWING: Sets of Detailed Plans:- Dated, Signed & Sealed by an Engineer or Architect holding a Florida State professional license. ❑ 2 Sets of Detailed Plans: Designed in accordance with the AAF Guide To Aluminum Construction in High Wind Areas. ❑ 2 Sets of Detailed Plans: Designed in accordance with any Approved Manual per fs-489.113. (I) ANY PLANS SUBMITTED WITHOUT COMPLYING WITH THE FOLLOWING SHALL BE RETURNED WITHOUT APPROVAL. ALL PLANS MUST BE IN INK AND ANY NOTATIONS IN PENCIL; WILL NOT BE CONSIDERED A PART OF A SUBMISSION. • All plans must be legible and must be designed in Architect's Scale on pages which are 81/2" x 11" or larger. • All relevant tables & details, if using a manual, must be properly highlighted and must match design checklists & drawings. • The plan view must include all dimensions; the location of the host structure and all materials must be sized and identified thereon. • All elevations.must be shown, including 4`s wall detail, dimensions and all material must be sized and identified. • All primary and secondary carrier beams, spans, spacing, gauges must be shown [Example: 2" x 8" x .072"]. • All methods of fastening or other details which are relevant to the design must be identified on the Plans. • All upright column heights, sizes, spacing and gauges must be shown as follows: [Example: 3" x 3" z .050"]. • All chair -rails, roof purlins, gins, channels, knee -bracing, k-bracing, cable bracing or any other required component must be sized and identified. • All ridge beams and super gutter or fascia attachments must be identified. • All roof pans or composite panels, with gauges and spans, must be sized and identified. • All footing, slab and ISO pier designs must be on the plans, per the Architect / Engineer's plans & specifications. • All light metal alloys which are utilized shall be designed in conformity with the Florida Building Code of 2007, Chapter 20, including 2006 revisions. • Barrier railings, if utilized, shall have all materials, fasteners and height specified and shall have self -closing, self - catching gates with picket spacing. (ln SITE -CONSTRUCTED SHEDS, HAVING ANY ALUMINUM COMPONENT, SHALL MEET ALL OF THE ABOVE REQUIREMENTS AND THE FOLLOWING ADDITIONAL ITEMS: (A) 2 copies of the current product approval [i.e. N.O.A. or State of Florida approval] with -the proposed "opening" or cladding component highlighted and with fasteners and design pressures, per FBC 1714, clearly identified. (B) 2 electric schematics, in accordance with the N.E.C., if applicable. (C) Design pressures, per ASCE-7, identified on the openings of all Plans. (III) HABITABLE ROOMS/ADDITIONS DESIGNS SHALL MEET ALL OF THE ABOVE REQUIREMENTS, EXCEPT AAMA SPECIFICATIONS, AND CHAPTER 13 OF THE FLORIDA BUILDING CODE. (IV) SUNROOMS (as defined in R202 and FBC 2002.6) MAY BE CONSTRUCTED, SO LONG AS THEY MEET ALL OF THE ABOVE REQUIREMENTS AND MUST BE IN STRICT COMPLIANCE WITH AAMA/NPEA/NSA2100.02 AND MEET THE FOLLOWING ADDITIONAL ITEMS: (1) The designer or engineer will state on all Plans, which Category of Design [3.1.2] will be used, inclusive of the definition. (2) If designing a Category 4 or Category 5 structure, as defined in the current Edition of 3.1.2.4 and 3.1.2.5, proper energy calculations and long form equipment sizing calculations shall be required, pursuant to Chapter 13 of the current State of Florida Building Code. (V) MOBILE HOMES (FAC 15C-2.0081 - PAC 15C-2.0072): ALL STRUCTURES ADJACENT TO OR NEW ROOF SYSTEMS (Pan or Composite) OVER EXISTING ADJACENT STRUCTURES TO A MOBILE HOME SHALL REQUIRE: (a) A 4`s wall or a current, signed original manufacturer's attachment approval letter which includes the model number, serial number and current owner's name and street address. (b) That the complete guide to H.U.D. specifications be strictly adhered to. (c) A Certified Florida Engineer may design the manner of attachment of the proposed structure to the host house but shall assume full responsibility for both structures' integrity by site. specific documentation. CERTIFICATION: ' This application is hereby made in order to obtain a permit to do the work and installations as indicated, and to obtain a certificate of capacity, if applicable, for the permitted work. NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE TO APPLICANT;_.. IN THE EVENT IT IS NOT YOUR RIGHT TITLE OR INTEREST THAT IS SUBJECT TO ATTACHMENT, THE APPLICANT DOES HEREBY MAKE A GOOD FAITH PROMISE TO DELIVER A COPY OF THE ATTACHED CONSTRUCTION LIEN LAW NOTICE TO THE PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT, AND DOES SO AS .A CONDITION PRECEDENT TO THIS PERMIT 1. If utilizing the AAF Guide to Aluminum Construction in High Wind Zones, I the Contractor/Owner Builder hereby certify that the components being used, fasteners type and fastening pattern meet all the requirements for the designated wind zones established by the county and take full responsibility for complying with the submitted design of the structure being permitted. 2. I further certify that all the foregoing information is accurate, that no work or installation has commenced prior to the issuance of a permit and that all work shall be performed in compliance with all applicable laws regulating construction and, zoning in this jurisdiction. I understand that separate permits may be required for ELECTRICAL, and HVAC, etc., not otherwise included with this building permit.application. 3. I , the Contractor / Owner Builder, have verified that the existing foundation meets the requirements of the Engineer of Record and is in adequate condition to withstand the uplift and weight of the aluminum structure and said structure will not exceAth oo t o"he structure that was in existence prior to remogl by thft storms. SIGNATURE STATE OT-M COUNTY OF The foregoing instrument was acknowledged before me me this !A day of ✓J &J Qn/M�, er_ 20 O by t,,_�Qls � it A4gWJc--, 9 rA,*i , who is personally known to me, or who has produced as identification. Notary Public State of Florida Raymorr����}��k��son My Corr�li�l;it3h DD919255 Expires 08/23/2013 ANT NOTICES: rJ STATE OF FLORIDA COUNTY OF ST L-J C t C--- The foregoing instrument was acknowledged before me me this -La day of Ajoy eAn , 20 io . , by - v--) Q,-s 8 Y 6k2A-2e--- 39,A j r , who is personally known _L� to me, or who has produced identification. State of Florida Expires 08/23/2013 9255 • TWO (2) SIGNATURES ARE REQUIRED. EACH SIGNATURE MUST BE NOTARIZED. IF APPLYING FOR THIS BUILDING PERMIT AS AN OWNER/BUILDER, THE OWNER -MUST PERSONALLY APPEAR, IN THE OFFICE LISTED ON THE FRONT OF THE APPLICATION, TO SIGN THIS APPLICATION & THE OWNER/BLDR AFFIDAVIT. • ALL SIGNATURES ON APPLICATION SUBMITTED SHALL BE ORIGINAL, SIGNED IN INK. COPIES, FAXES, OR STAMPED REPRODUCTIONS ARE PROHIBITED. • WHEN A PERMIT IS AVAILIBL.E FOR ISSUANCE BUT IS NOT PICKED UP WITHIN THIRTY (30) DAYS AFTER NOTIFICATION OF AVAILIBILITY, IT WILL, BE VOIDED. IF THE APPLICATION IS RESUBMITTED, AN ADDITIONAL FEE WILL BE CHARGED. JOSEPH E. SMITH, CLERK OF THE CIRCUIT CURT — SAINT LUCIE COUNTY FILE # 3536118 OR BOOK 325 PAGE 2112, Recorded 11/19/2010 at 0�=�`., PM AFTER RECORDING -RETURN TO: PERMIT NUMBER: NOTICE OF COMMENCEMENT The undersigned hereby given notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes the following information is provided in the Notice of commencement. _ 1. DESCRIPTION OF PROPERTY (Legal description and street address) cr50 r7 S 7hGuom � ve f 1 )r TAX FOLIO NUMBER: S5I9-g414-0WI-t)Ib-{O 3. OWNER INFORMATION: a. Name: f'lt rlxi+ b. Address: 1502 c. Interest in.property: fywrld-i d. Name and Address of fee simple titleholder (if other than owner) nn 4. CONTRACTOR'S NAME, ADDRESS AND PHONE NUMBER: �F—i�� 4, T l.C,try yju(^n dL60.—%C t'L)YC.(-1 5. SURETY'S RMME, ADDRESS, AND PHONE NUMBER AND BOND AMOUNT: 6. LENDER'S NAME, ADDRESS AND PHONE NUMBER: 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13 (1) (a) 7., Florida Statutes: NAME, ADDRESS AND PHONE NUMBER: 8. In addition to himself or herself, Owner designates the following to receive a copy ofthe Lienor's Notice as provided In Sectlon713.13 (1) (b). Florida Statutes: NAME, ADDRESS AND PHONE NUMBER: 9. Expiration date of notice of commencement (the expiration date Is 1 year from the date of recording unless a different date is specified) ,20 g tur f Owner or wn 's orized OHleer/Dlrector/Partner/Manager State of Flo. County of �SD21'�bf�Cf-(- - �1Y1eIr Print Narde and Provide Signatory's Title/Office The Foregoing instrument was acknowledged before me this H day of MAJQ 20 / V By:3N,sp r C.t�ri3�! 1— as b-.1 N e%Z (Name of Person) (Type of authority... e.g.,Owner, offic o 1 f �^1 V*'r'4 Notary Public State of Florida -FJ A � ` S V N My CommissionRaymond Atkinson DDe192b5 (Printed Name of Notary Public) (Signs of Notary Public) �Y Exoire60a12312013 Under penalties of perjury, I declare that 1 have read the foregoing and that the fads In It are true to the best of my knowle ge an belief (section 92.525, Florida Statutes). Signature(s) of Owner(s) or Owner(s)' Authorized Officer/Director/Partner/Manager who signed above: Br• By: �OG�L�P1 � ++ - D1, I THIS IS ff'rEi�7trYru.grTt,r,.._ . STATE OF FLORI&q ST. UXIE COUNTY Linda Pendarvis From: Linda Pendarvis Sent: Monday, January 24, 2011 8:20 AM To: Linda Pendarvis; 'admin@theporchfactory.com' Cc: Paula Bushby Subject: RE: 9507 S. Indian River Drive Dear Ms. Meade-Brann I was out Friday afternoon and I wanted you to know that I did receive the revised plans for the subject property. Although I did not receive scale plot plans. I will forward this project to the plans examiner because the construction is not going outside the footprint of the home there fore does not appear to encroach into any setbacks. If an encroach does occur it may require a variance. This is not the normal procedure for this type of permit application. In the future please adhere to the requirement of the "Application for Aluminum Structures Permit" that you submit two (2) scaled plot plan. If you have any questions please contact me. Linda From: Linda Pendarvis Sent: Friday, January 14, 20114:35 PM To: 'admin@theporchfactory.com' Subject: 9507 S. Indian River Drive Dear Ms. Meade-Brann I called your office on Tuesday 1/11/11 regarding the permit for the referenced address. The survey submitted does not show the location of the proposed patio roof and pool enclosure according to the dimensions on the application and there was only one survey and the application indicated that there were two scaled plot plans. If you have two scaled plot plans please submit them. If you have any questions please call me. This permit cannot move forward to the next review process until we have this information. Thank you Linda Linda Pendarvis, Planner Planning Division Planning & Development Services St. Lucie County 2300 Virginia Avenue Fort Pierce, FL 34982 772-462-1562 pendarvisl@stlucieco.org Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and / or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error, please notify the sender by reply e-mail and delete all materials from all computers. Linda Pendarvis From: admin@theporchfactory.com Sent: Monday, January 17, 2011 1:55 PM To: Linda Pendarvis Subject: RE: 9507 S. Indian River Drive Hello Linda, I had to send the print back to the engineer to make a few modifications. As soon as I receive it from Bennett, we will bring it in and make the necessary adjustments to the plans. Thank you!! Warm Regards, Heather Ring R & T Aluminum Services, Inc. dba "The Porch Factory" Office: 772-465-6772 admin@theporchLctory.com From: Linda Pendarvis Imailto:pendarvisl@stlucieco.org] Sent: Friday, January 14, 2011 4:35 PM To: 'admin@theporchfactory.com' Subject: 9507 S. Indian River Drive Dear Ms. Meade-Brann I called your office on Tuesday 1/11/11 regarding the permit for the referenced address. The survey submitted does not show the location of the proposed patio roof and pool enclosure according to the dimensions on the application and there was only one survey and the application indicated that there were two scaled plot plans. If you have two scaled plot plans please submit them. If you have any questions please call me. This permit cannot move forward to the next review process until we have this information. Thank you Linda Linda Pendarvis, Planner Planning Division Planning & Development Services St. Lucie County 2300 Virginia Avenue Fort Pierce, FL 34982 772-462-1562 pendarvisl@stlucieco.org Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error, please notify the sender by reply e-mail and delete all materials from all computers. ALUMINUM ALLOY 0005-T5 I— rn rn r rn D O z WIND ZONE: 140 MPH EXPOSURE: C IMPORTANCE FACTOR: .77 BASIC WIND PRESSURE: 23 ROOF PSF SCREEN: 8 WINDWARD WALL PSF SCREEN: 28 LEEWARD WALL PSF SCREEN: 23 - 00 I- v I00, VN ^N X X XX ' N N IUN. N 10' I HEREBY CERTIFY THAT THESE PLANS MEET OR EXCEED THE REQUIREMENTS OF THE 2007 FLORIDA BUILDING CODE WITH 2O09 SUPPLEMENTS, CHAPTER 20 A5M35 AND THE 2005 ADM PART I -A * II AND ASCE 7-05. ADDENDUM TO PLANS DATED 12-09-10 EXISTING CONCRETE RIBBON FOOTER 14" d a c o e : °• 6 < d d ° < .. E GRADE .4 a d ° a .:L d. e / d (2) #50 BAR ° MIN 3" OFF \\/ GROUND END VIEW SIDE VIEW (2) #50 BAR DOWELED INTO EXISTING CONCRETE WITH EPDXY (MIN 411) 40 2X2 lr�2,','G 2 G 2 G 2 G 2 0 2 G 2 G 2XIG s T. LL``CIE CMUTINTr BON DL4G DfV1816, 2X2 REVIE«'ED FOR CON T _' E .......... 20' REVIEWED S P N FLANS ANPEA i'1IT MUST BE IaPT ON 7 u 5) OR NO M Sa ECTIO`ti' FILL BE 1V4&DE. G u 2�/4 L•J ; LJ ; LJ ; L j ;LJ L XX - Solid Roof - g'_ 113" :5" 5UPER GUTTER Edge Beam 9' oad I G I %'- I i' Trih C4 ADD Tiifi oad NI— N Elite Roof 3nDiliLoad :2X8BeamSpan :EXISTING 5LA5 END51 RIBBdN EliteSpm2 O j �, FOOTER5 (40) 2" X:8" X 0.'.072" X:0.224. CARRIER BEAM ' X X CON N -----_----------•-------------------•-------------•------------------------------------------------------------ -- N1-- 70' RESIDENCE PLAN VIEW OF PROPOSED ENCLOSURE DRAWN 1 2-09-10. ADDENDUM TO ADD RIBBON FOOTERS WITH DOWELING REQUIREMENTS DRAWN 01-1 7-1 1. DATE: 0 1- 17-1 1 5CALE: 1 /8" F- U O U X6,�ro ALUMINUM ALLOY 6005-T5 I— rn rn r rn O z WIND ZONE: 140 MPH EXPOSURE: C IMPORTANCE FACTOR: .77 BASIC WIND PRESSURE: 23 ROOF PSP SCREEN: 8 WINDWARD WALL P5F SCREEN: 29 LEEWARD WALL PSF 5CREEN: 23 U.1 Q J U1 = N NN N N NN DO ' i -NIP J i I HEREBY CERTIFY THAT THESE PLANS MEET OR EXCEED THE REQUIREMENTS OF THE 2007 FLORIDA BUILDING CODE WITH 2O09 SUPPLEMENTS, CHAPTER 20 A5M35 AND THE 2005 ADM PART I -A * II AND ASCE 7-05. N O UVA] 13 ? V]'2 189 15 19�b IL I III I I�III� I Ida III I I� III I 1�III� I I�III� I I� ( I I � � I L ?-XL CLIIC KUUr rANr-L5Y51CM ................. 20' : 3" X 48" X 0.024" THICK ALUMINUM S P N 3105 H-14 OR H-25 ALUMINUM ALLOY MIN. # I DENSITY E.P.S. FOAM CORE 10'I .............................................. GI 51 I II /\�1 J L-1 :L-1 L-j : L ... .II 1- Solid Roof J� g�_ 113" ,f g'_ II' �:511 5UPER GUTTER Edge Beam 1 (9 9' Trfh Load 'I I c I 16 Trib oad 7 - N I— N Elite Roof W Trib Load :2X8Beam span Elite Span (40) 2" X 8" X 0.072" X:0.224' CARRIER BEAM ` X X --------------------------------- - - 701 I (n Lu U-j Q Ln C\I D u.i U U z Q U 't 0 w u0-N DECrj 6 20 RESIDENCE s"EET N I I V 0 U PLAN VIEW WITH LEFT REAR ELEVATIONS WITH TRIBUTARY LOAD5 FOR MAIN FRAME WIND RE515TANCE COMPONET5 AND SPANS FOR ELITE COMP051TE ROOF DATE: 1 2-09-10 SCALE: 1/8" = I' o> 5 p I t `ROOF BEAM 2" X 0" X 0.050" X 0. 1 20" S.M.B. (d - 1 /2" = d GUSSET) 'ROOF BEAMS w 0" - 1 /2" = 5-1/2" GUSSET 2" X G" X 0.050" X 0. 1 20" S.M.B. (SCREWS @ 24" O.C.) v `WALL BEAMS Ucc LUIt 2" X 4" X 0.046" X 0, 100" S.M.B. (SCREWS @ 24" O.C.) 2 Q CHAIR RAIL OR WALL GIRTS ATTACHED TO z Q `r ov c m ® BEAM OR POST WITH INTERNAL "U" CHANNEL �. N v ® O ® WITH MIN. (4) # 10 S.M.S. < °o �- ® ® O It 2 v ® ® ® ® ® INTERNAL SCREW BOSSES �i ® REQUIRE (4) # 10 X 2" 5.M.5. 2"XG"X0.050"X0.120"5.M.5. o ® z z _ U --------- ------ U � U z �NO INTERNAL 5-1/2" X 0. 1 25" GUSSET PLATE (5052 H-32) (1) # 12 X 3/4" SMS w w >1 U- # 12 X 3/4" S.M.S. (MIN. OF G FOR 2" X G" BEAM) @ 24" ON CENTER >m � o EACH SIDE OF SPLICE * EACH SIDE OF BEAM TOP 4 BOTTOM Q u z o MAINTAIN 2d EDGE DISTANCE ON SCREWS OF EACH BEAM. a z w N a)a) °L z ON O U ROOF BEAM GUSSET PLATE DETAILS SCALE: 2" = P GIRT TO P05T OR PURLIN TO BEAM ATTACHMENT SCALE: 2" = P BEAM 5TICHTING DETAIL (2XG ROOF 2X4 WALL) SCALE: 2" = I' o �r U = Lo 1-3/4" X 3-3/4" X 0.000" STRAPS HEADER DIAGONAL PURLIN o (4) # 12 X 3/4" SMS <o �- TOP * BOTTOM OF BEAM z N (12)#12X3/4"SMS „ 2 X 2 X 0.044 PURLIN 2"X8"X0.050"STRAP Lea EACH 51DE OF BEAM (8) # 12 X 3/4" SMS w 91 g z (TOP SIDE ONLY) a- W 0 o 2" X 2" X 0.044" J EXTRUSION a 2" X 2" X 0.044" ® ® 1 " X 2" X 0.044" OPEN ®® ®0 ®® „ „ „ BACK EXTRUSION ® 2X4XO.OG3 • 4 4 4 ° °lu u} � N� w = o hu ®® REC / CHANNEL v tn ®®® ®®®® ®® (4) # 10 X 3/4" 5M5 i `" o °o # 10 X 1- I /2" SMS @ 24" ON CENTER ®® `ROOF BEAM # 10 X 1- I /2" SMS EACH SIDE OF 2" X G" X 0.050" X 0. 1 20" S.M.B. @ 24" ON CENTER CONNECTION POST m "WALL BEAM 0 2"X4"X0.04G"X0.100"5.M.B. 2"X4"X0.046"X0.100" z WALL POST COLUMN DEC 16 201A 'ALL 5.M.5.5 ARE TO BE 5EAL o sneer 5TICHED W/ # 12 X 3/4" SMS @ 24" O.C. (BOTH SIDES) . 2 LD 0 FULL LAP CONNECTION ROOF TO WALL DETAIL SCALE: 2" = P ROOF PURLIN TO 51DE WALL CONNECTION DETAIL SCALE: 2" = P WIND BRACING DETAILS DATE: 1 2-09-10 SCALE: N.T.S. of 5 U p SAVE RAIL WALL POST ® ® 4" X 4" X 0.063" PLATE u� U w L/ -t o ®® 2" X 2" X 0.044" BRACE ® ® INTERNAL OR EXTERNAL RECEIVING CHANNEL BASE ATTACHED TO CONCRETE WITH: Q w o 0 Z U 62/ U N O o DISPLAYED SCREWS ®® (2) I /4" X 2-1 /2" WEDGE 50LT5 (4) # 14 X 3/4" SHEET METAL SCREWS W ARE # 12 X 3/4" CHAIR RAIL ®® m O O O ® ® ® u� w Lu U o N O W't� g 3" X 3" X 0.090" POSTS 3" X 3" X 0.090" POSTS � Z 0 z Qww 0 ® (NOTE FASTENING PATTERN) o' W o co o o' uj o ®® O I"X2"X0.044" 50LE PLATE ' 1 /4 X I 1 /4 EMBEDMENT WEDGE ANCHORS m ..'.. OR TAPCONS @ 24 ON CENTER PLATED K-BRACING CONNECTION WITH REQUIRED # OF SCREWS SCALE: 2" = 1' SIDE VIEW POST TO CONCRETE CONNECTION FRONT VIEW POST TO CONCRETE CONNECTION in - N [` Z N z II II II 2 X 2 X O.OG3 ANGLES ANCHORED TO �`p,�+, m o Z yjE Q Z 2" X 4" X 0.04G" X 0. 1 00" WALL POSTS " I F PAVERS ARE ADDED ON TOP OF CONCRETE W 6 E p U- ° � o WITH (4) # 12 X 3/4" S.M.S. AND INTO ANCHOR LENGHT MUST BE INCREASED TO ACHIEVE J � n o CONCRETE WITH (2) 1 /4" X 2-3/4" WEDGE 2" X 4" X 0.04G" X 0. 100" 1-0 1 -1 /4 MIN. EMBEDMENT INTO CONCRETE SLAB. (n u ti- ANCHORS. (BOTH SIDES OF POST) INSTALL (1) # 10 X 3/4" S.M.S. °� �� Z @ 24" ON CENTER w = m � EACH 51DE OF BEAM 1 /4" X 1-1 /4" EMBEDMENT WEDGE ANCHORS 3 ° THRU O.OG3" ANGLES AND @ 24" ON CENTER. u u Lu m 0 0 0 00 0 1" X 2" X 0.044" SOLE PLATE--- 4L o r z TAPCONS MAY BE USED IN :� � �:�� :�� EC 16-2010 LIEU OF ` r E WEDGE A NCHO S , A. k .. SEAL O O N S I1EET • F" f': 0 SIDE VIEW CONNECTION OF 2" X 4" POSTS TO CONCRETE WITH ANGLES FRONT VIEW CONNECTION OF 2" X 4" POSTS TO CONCRETE DATE: 1 2-09-16 SCALE: 2" = P of 5 U p