Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSI DATE: St PERMIT NUMBER: -0 1'0 SCANNED BY Lucie County PLANNING & DEVELOPMENT SERVICES DEPART71 BUILDING & CODE REGULATIONS DIVISION 2300 Virginia Avenue Fort Pierce, FL 34982 (772) 462-1553 APPLICATION FOR REPLACEMENT OF WINDOWS, SKYLIGHTS, DOORS & OVERHEAD GARAGE DOORS I. LOCATION/SITE ADDRESS: 2. PARCEL ID NUMBER: 47 La Puerta Del -Norte, Ft. Pierce, FL. 34951 1301-113-0001-0001 3. DESCRIPTION OF PROJECT OR WORK ACTIVITY: Replace windows on the mobile home size for size (no change in the openings) with energy efficient vinyl frame SIMONTON 43-17 single hung 4. TYPE OF STRUCTURE: SFR 5. OWNERS INFORMATION Name: Josephine Parris Address: City: _ Zip: 47 La Puerta Del -Norte Ft. Pierce State: FL 34951 Phone: 772-466-3734 MOBILE HOME Yes OTHER 6. CONTRACTOR'S INFORMATION FL Reg/Cert #: CGC060140 County Cert #: Business Name: 26290 Permaguard, Inc. Phone Number: 813-695-5579 Windows, Swing Doors, Skylights, Fixed Glass Opening Design Pressure A.S.C.E - 7 Design Pressure Product Manufacture Model # Method of Attachment # Florida Product Approval # 120 mph 1130 mph 140 mph Windows & Skylights Exposure B Simonton 43-17 5414.14 Exposure C Overhead Garage Doors < 30' - F.B.C. Table 1609.6 (1) + 1609.6 (2) B- Size C- Size 7. VALUE OF CONSTRUCTION: $ 14,000.00 FEES DUE: o RECEIPT: 917--�37 OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in compliance with all applicable laws regulating constru and zonin Petros S. Manolatos PRINT QUALI IE S/OWN S NAME LIFIER/OWNER STATE OF FLORIDA, COUNTY OF ACKNOWLEDGED BEFOR E THIS DAY OF 20 BY WHO IS PERSONALLY KNOWN TO ME OR WHO HAS PRODUCED AS IDENTIFICATION. DAWN MILONE IGNATURE OF NOTARY R PRINT NAME O - i-.r +r MY COMMISSION # DD 852587 TITLE: NOTARY PUBLIC COMMISSION NUMBER ',+' •.,,'O� EXPIRES: March 2-2, 2013 —Bonded ihru Notary Public Underwriters NOTICE TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING JOSEPH E. SMITH, CLERK OF THE CIRCUIT COURT — SAINT LUCIE COUNTY FILE # 3543881 OR BOOK 32F7'PAGE 1644, Recorded 12/17/2010 at 1F,, -', PM AI'IT.R RECORDING -RETURN TO- Pc4 guard,Inc. 128 Phillips Rd. Florahome, FL. 32140 PERMIT NUMBER: ., .. NOTICE OF COMMENCEMENT The undersigned hereby given notice that improvement will be made to certain real property, and in accordance with Chapter 713. Florida statutes the following information is provided in the Notice o(commencement. I. DESCRIPTION OF PROPERTY (Legal description and street address) TAX FOLIO NUMBER: 1301-1 13-0001-0001 SUBDIVISION LOCK -TRACT___ -- LOT BLDG UNIT 1-34 39E less N 1069.54 ft 2. GENERAL DESCRIPTION OF IMPROVEMENT: Window replacement 3. OWNER INFORMATION: a. Name Josephine Parris b. Address 47 La Puerta Del- Norte Fort Pierce, FL. 32951 c. interest in property Owner d. Name and address of fee simple titleholder (if other than owner) N/A 4. CONTRACTOR'S NAME, ADDRESS AND PHONE NUMBER: Permaguard, Inc. 128 Phillips Rd. Florahome, FL.32140 813-695-5579 S. SURETY'S NAME, ADDRESS AND PHONE NUMBER AND BOND AMOUNT: N/A 6. LENDER'S NAME, ADDRESS AND PHONE NUMBER: N/A 7, Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13 (1)(a) 7., Florida Statutes: NAME, ADDRESS AND PHONE NUMBER: Josephine Parris, 47 La Puerta Del Norte, Ft. Pierce, Fl. 34951 8. In addition to himself or herself, Owner designates the following to receive a copy of the Lienor's Notice as provided in Section 713.13 (1)(b), Florida Statutes: NAME, ADDRESS AND PHONE NUMBER: Permaguard, Inc. 128 Phillips Rd. Florahome, FI. 32140 9. Expiration date of notice of commencement (the expiration dale is I year from the date of recording unless a different date is specified) February , 1 , 2D 11 ,h�.�.c ^r 2. _��/��iL• ,1y S E-' /"F! : /i: f.. � NA� IQ i S' ature Wf Owner or Print T'tlelOtTice Owner's Authorized Offtcer/Director/Partner/Manager PETROS SPIROS MANOLATOS MY COMMISSION # D0937083 State of Florida EXPIRES December 06.2013 Cauniy of SX, \ h C 1k, par 39a-0153 FpRpppye �.uy,� The foregoing instrument was acknowledged before me this ayof ,�� S C- . , 20-lio_. By3asl2eW I a�%_ 'q�ta;s as r) �6�) 4.�. (Name of person) (Type of aut ority...e.g. Owner, officer, trustee, attorney in fact) ror (Name of party on behalf of whom instrument was executed) Personally Known_ or produced the following type of ID: i�4i!w MArvQLA}gs (Printed Name of Notary Public) Jg0a1oq1N?.1�aryP.t lic) . . Under penalties of perjury, I declare that I have read the foregoing and that the facts in it are true to the best of my knowledge and belief (section 92.525, Florida Statutes). Signalure(s) of Owner(s) or Owncr(s)' Authorized Officer/Director/Partner/Manager who signed above: By R-( Vtnn(ft—lip) STATE OF FLORIDA ST. LUCIE COUNTY THIS IS TO CERTIFY THAT THIS IS A TRUE AND CORRECT COPY OF THE ORIGINAI_�, JO:SEPH S ITH, CLERK By:— �•. IlV.'r . Date• �_„ Florida Building Code Online , 5 r4aw OF unity Affairs,rx BCIS Home Log In I User Registration I Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff I BCIS Site Map Links I Search Product Approval !YI USER: Public UserF I LL"w C 0 to' 20" Y Product Approval Menu > Product or Application Search > Application List > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Certification Agency Validated By Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By FL5414-R4 Revision 2007 Approved Simonton Windows 1 Cochrane Ave Pennsboro, WV 26415 (800) 746-6687 Ext4825 patricia_robison@simonton.com Patricia Robison patricia_robison@simonton.com Patricia Robison 1 Cochrane Or Pennsboro, WV 26415 (304) 659-2903 Ext4825 patricia_robison@simonton.com AAMA 1827 Walden Office Square Suite 550 Schaumburg, IL 60173 (847)303-5664 webmaster@aamanet.org Windows Single Hung Certification Mark or Listing CONCEAL FASTENERS ORATTACH�I'S AN THE RWSPONS�9��1LDDfTY��V Tm �VIOMROF11G111 M THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPROTOMS THAT MAY BE NECESSARY IN Ogg To 001fty WITH AIDAPPWOMW 00019, American Architectural Manufacturers Association American Architectural Manufacturers Association Standard AAMA/WDMA/CSA 101/I.S 2/A440 Year 2005 STD LUOIB COUNTY BUILDING 01 R an O® Pl.t:WhL) BY � Product Approval Method Method 1 Option A DATE p PLANS ND PERMIT MUST 0 EPT ON JOB OR NO INSP TION WILL BE MADE http ://www. floridabuilding. org/pr/pr_app_dtl. aspx?param=wGEVXQwtDgtHJPwMo6 eH... 12/21 /2010 l;lorida Building Code Online Date Submitted Date Validated Date Pending FBC Approval Date Approved FILL7 COPY 10/26/2009 00• 0. 00• 0• 00• Summary of Products FL # IModel, Number or Name IlDescription 5414.1 41-18 41-18 vinyl Single Hung sold under the following marketing name: Profinish Brickmould 300 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL5414 R4 C CAC 41-18 SH 5201 30.odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 06/03/2012 Design Pressure: +30/-30 Installation Instructions Other: Single Hung, 52x71 FL5414 R4 II IN0228 52x75 sh.odf Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 5414.2 41-18 41-18 Vinyl Single Hung, sold under the following marketing names: Profinish BrickMould 300 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL5414 R4 C CAC 41-18 SH 44x63 35.odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 04/07/2012 Design Pressure: +35/-35 Installation Instructions Other: Single Hung, 44x63 FL5414 R4 II IN0228 52x75 sh.odf Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 5414.3 41-18 41-18 Vinyl Single Hung, sold under the following marketing names: Profinish BrickMould 300 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL5414 R4 C CAC 41-18 SH 36x63 45.odf Approved for use outside HVHZ: Yes FL5414 R4 C CAC 41-18 SH 44x63 R45.odf Impact Resistant: No Quality Assurance Contract Expiration Date Design Pressure: +45/-45 04/07/2012 Other: Single Hung, 36x63, 44x63 Installation Instructions FL5414 R4 II IN0228.odf Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 5414.4 41-18 41-18 Vinyl Single Hung, sold under the following Marketing name: Profinish BrickMould 300 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL5414 R4 C CAC 41-18 SH 4802 R40.Ddf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 10/10/2012 Design Pressure: +40/-40 Installation Instructions Other: Single Hung, 4802 FL5414 R4 II IN0228.odf Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 5414.5 41-18 �F41-18 Vinyl Single Hung, sold under the following marketing name: Profinish BrickMould 300 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL5414 R4 C CAC 41-18 SH 3606 50.odf Approved for use outside HVHZ: Yes FL5414 R4 C CAC 41-18 SH Twin 73x74 R50.odf Quality Assurance Contract Expiration Date Impact Resistant: No Design Pressure: +50/-50 04/07/2012 Other: Single hung, 3606, Single Hung T mull twin Installation Instructions 7304 FL5414 R4 II IN0228.odf FL5414 R4 II IN0230.odf http://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgtHJPwMo6eH... 12/21 /2010 Florida Building Code Online - FILE Verified By: American Architectural Manufacturers COPYAssociation Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 5414.6 41-18 41-18 Vinyl Single Hung T mull twin, sold under the following marketing name: Profinish BrickMold 300 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL5414 R4 C CAC 41-18 SH Twin 89x60 R30.pdf Quality Assurance Contract Expiration Date Approved for use outside HVHZ: Yes Impact Resistant: No 09/12/2012 Design Pressure: +30/-30 Installation Instructions Other: Single Hung T mull twin, 89x60 FL5414 R4 II IN0230.pdf Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 5414.7 41-18 41-18 Vinyl Single Hung T mull twin, sold under the following marketing name: Profinish BrickMold 300 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL5414 R4 C CAC 41-18 SH 73x74 twin 45.odf Quality Assurance Contract Expiration Date Approved for use outside HVHZ: Yes Impact Resistant: No 06/04/2012 Design Pressure: +45/-45 Installation Instructions Other: Single Hung T mull twin, 7304 FL5414 R4 II IN0230 SH Tmull twin.odf Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 5414.8 11 41-18 41-18 Vinyl Single Hung T mull triple, sold under the following marketing name: Profinish BrickMold 300 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL5414 R4 C CAC 41-18 SH Triple 109x63 r35.pdf Quality Assurance Contract. Expiration Date Approved for use outside HVHZ: Yes Impact Resistant: No 09/09/2012 Design Pressure: +35/-35 Installation Instructions Other: Single Hung T mull triple, 109x63 FL5414 R4 II IN0232.1)df Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 5414.9 41-18 41-18 Vinyl Single Hung T mull triple, sold under the following marketing name: Profinish BrickMold 300 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL5414 R4 C CAC 41-18 SH Triple 10902 R45.pdf Quality Assurance Contract Expiration Date Approved for use outside HVHZ: Yes Impact Resistant: No 06/19/2013 Design Pressure: +45/-45 Installation Instructions Other: Single Hung T mull triple, 10902 FL5414 R4 II IN0232.1)df Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 5414.10 =1 43-06 43-06, sold under the following marketing names: THD @ Home Services 6060, Profinish Builder, Vinyl SH Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL5414 R4 C CAC 43-06 SH 36x74 R35.pdf Approved for use outside HVHZ: Yes FL5414 R4 C CAC 43-06 SH 44x63 R35 a.pdf FL5414 R4 C CAC 43-06 SH 5201 R35 1152013.pdf Impact Resistant: No Quality Assurance Contract Expiration Date Design Pressure: +35/-35 Other: Single Hung, 44x63, 3604, 5201 01/15/2013 Installation Instructions FL5414 R4 II IN0160.pdf Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 5414.11 -11 43-06 43-06, sold under the following marketing names: THD h4://www. floridabuilding. org/pr/pr_app_dtl. aspx?p aram=wGEVXQ WtDgtHjpwMo 6eH... 12/21 /2010 Florida Building Code Online - 11 jj@ Home Services 6060, Profinish Builder, Vinyl SH Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL5414 R4 C CAC 43-06 SH 48x72 R40 mav09.odf Quality Assurance Contract Expiration Date Approved for use outside HVHZ: Yes Impact Resistant: No 03/10/2013 Design Pressure: +40/-40 Installation Instructions Other: Single Huna, 48x720 FL5414 R4 II IN0160.odf Verified By: American Architectural Manufacturers aAssociation Er YEvaluation Created by Independent Third Party: Reports Created by Independent Third Party: 5414.12 43-06 43-06, sold under the following marketing names: THD @ Home Services 6060, Profinish Builder, Vinyl SH Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL5414 R4 C CAC 43-06 SH 44x63 R45.odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 05/20/2013 Design Pressure: +45/-45 Installation Instructions Other: Single,Hung, 44x63 FL5414 R4 II IN0160 (2).odf Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 5414.13 43-06 43-06, sold under the following marketing names: THD @ Home Services 6060, Profinish Builder, Vinyl SH Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL5414 R4 C CAC 43-06 SH 32x62 R50.odf Approved for use outside HVHZ: Yes FL5414 R4 C CAC 43-06 SH 36x74 R50.odf Impact Resistant: No FL5414 R4 C CAC 43-06 SH 36x84 R50 may09.[)df Quality Assurance Contract Expiration Date Design Pressure: +50/-50 Other: Single Hung, 36x84 3604 32x62 11/11/2012 Installation Instructions FL5414 R4 II IN0160 (2).1)df Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 4 4. ,4 43 17 43-17, sold under the following marketing names: Profinish Contactor, Profinish Master, Amcraft Grand Estates New Construction, vinyl SH Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL5414 R4 C CAC 43-17 SH 3606 LC50 09.odf FL5414 R4 C CAC 43-17 SH 36x96 R50 09.odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No Design Pressure: +50/-50 12/08/2012 Other: Single Hung, 36x76, 36x96 Installation Instructions FL5414 R4 II IN0162.odf Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 5414.15 43-17 under the following marketing names: J F317old Contactor, Amcraft Grand Estates New tion, Vinyl T mull SH twin Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL5414 R4 C CAC 43-17 SH Twin 89x63 R30.ndf Quality Assurance Contract Expiration Date Approved for use outside HVHZ: Yes Impact Resistant: No 11/11/2012 Design Pressure: +30/-30 Installation Instructions Other: SH T mull twin 89x63 FL5414 R4 II IN0161.odf Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 5414.16 43-17 43-17, sold under the following marketing names: Profinish Contactor,Amcraft Grand Estates New Construction, vinyl SH T mull twin Limits of Use 71 Certification Agency Certificate hq://www. floridabuilding. org/pr/pr_app_dtl.aspx?param=wGEVXQWtDgtHjpwMo6eH... 12/21 /2010 Florida Building Code Online 1 Approved for use in HVHZ: No FL5414 R4 C CAC 43-17 SH Twin 73x63 R35.pdf FL5414 R4 C CAC 43-17 SH44x63 R35.pdf Approved for use outside HVHZ: Yes Impact Resistant: No Quality Assurance Contract Expiration Date Design Pressure: +35/-35 11/11/2012 Other: SH T mull twin, 73x63 Installation Instructions FL5414 R4 II IN0161.pdf FL5414 R4 II IN0162.pdf Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 5414.17 43-17 43-17, sold under the following marketing names: Profinish Contactor,Amcraft Grand Estates New Construction, vinyl SH T mull twin Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL5414 R4 C CAC 43-17 SH 73x74 R45.Ddf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 07/31/2013 Design Pressure: +45/-45 Installation Instructions Other: SH T mull twin, 7304 FL5414 R4 II IN0161.pdf Verified By: American Architectural Manufacturers Association .Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 5414.18 43-17 43-17, sold under the following marketing names: Profinish Contactor, Amcraft Grand Estates New Construction, Vinyl SH T mull twin Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL5414 R4 C CAC 43-17 SH Triple 109x63 r35.Ddf Quality Assurance Contract Expiration Date Approved for use outside HVHZ: Yes Impact Resistant: No 09/10/2012 Design Pressure: +35/-35 Installation Instructions Other: SH T mull triple, 109x63 FL5414 R4 II IN0248 Model (1) 4317 tmull triple.ndf Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Back Next Department of Community Affairs Florida Building Code Online Codes and Standards 2555 Shumard Oak Boulevard Tallahassee, Florida 32399-2100 (850) 487-1824, Fax (850) 414-8436 cp 2000-2010 The State of Florida. All rights reserved. Privacy Statement I Copyright Statement I Accessibility Statement I Plug-in Software I Customer Service Survey I Contact Us Product Approval Accepts: eche'ct M —10 securitvucralcs VerlSlpn � . � Trailed VLMIlVV Y � W http : //www. floridabuilding. org/pr/pr_app_dtl. aspx?param=wGEVXQwtD gtHJPwMo6 eH... 12/21 /2010 CENGINEERING • INSPECTIONS CERTIFICATIONS TESTING December 14, 2010. FlUice C'Opy RE: Window replacement at: Parris Mobile Home FUGUA 1986 Model Prestige 600 Series Serial # FX258-8-24 St. Lucie County To Whom It May Concern: This is to advise that the mobile home is capable of supporting the weight of the proposed replacement windows without adding any additional supports. The replacement windows are Simonton Pro Finish Contractor, 43-17, vinyl S.H. with Florida product approval-# 5414.14. The wall pressures for component and cladding for 140 mph, 3 second gust, are +35.3 psf and --47.2 psf -for zone 5, exposure B, effective wind area of 10 square feet. Similarly for zone 4 the component and cladding pressures are +35.3 psf and —38.2 psf. Respectfully, HILBORN, WERNER, CARTER & ASSOCIATES, INC. Dietrich Kindl, R.A. HILBORN, WERNER, CARTER AND ASSOCIATES, .INC. 1627 SOUTH MYRTLE AVENUE CLEARWATER, FLORIDA 33756 (727) 584-8151 FAX:.(727) 586-3343 / (727) 585-2392 1 (727) 587.0447 Modular Qaple Inapecden MODEL DESIGNATION: Simonton Single Hung Series 43-17 Vinyl Window MAXIMUM OVERALL NOMINAL SIZE: See Size Chart DESIGN PRESSURE RATING: Anchors: See Size Chart Windows: Design Pressure Ratings Vary, See Corresponding AAMA Test Report or Dade NOA or Florida P.E. Evaluation. USABLE CONFIGURATIONS: 0 X GENERAL DESCRIPTION: The head and side jambs are extruded PVC. The wall thickness through which the anchor screw penetrates is a minimum of 0.070". SIZE CHART OVERALL SIZE DP RATING WIDTH HEIGHT 44" 96" ±20 PSF 48" 80" ±25 PSF 44" 63" ±35 PSF 36" 76" f50 PSF 36" 96" ' REVISIONS: REVISED BY; DATE: NO P.E. SEAL REQUIRED 8 x BD AND 44 x 96 1 ADDED SIZES 48. M717 CHART TO T,D.D. 01/17/( INSTALLATION SUPPORTED 2 ADDED "NO PE SEAL REQUIRED" NOTE. T.D.D. 02/26/1 BY AAMA TEST REPORTS 3 CORRECTED MODEL D NA i M 4 —O6 T.D.D. 05/13/( 4 ADDED 44 x 63 UNIT WITH *35.0 PSF T.D.D. 04/10/I 5 UP A ANCMO L CA N N W S T.D.D. 1D/13/( REPORTS. SILICONE CAULK #6 X 1 1/4" MIN. WOOD 2X BUCK SCREW WITH 1.00" MIN. EMBEDMENT INTO WOOD SILICONE CAULK 1/4" MAX. SHIM 1 HEAD 1 4X SCALE 2X BUCK SILICONE CAULK #6 X 1 1/4" MIN. WOOD 1/4" MAX. SHIM SCREW WIEMBEDM NTD INTO WOOD 1/4" MAX. SHIM SILICONE CAULK J ts SILICONE CAULK #6 X 1 1/4" MIN. WOOD 1 JAMB SCREW WITH 1.00" MIN. 2X BUCK 4X SCALE EMBEDMENT INTO WOOD SILICONE CAULK 1 SILL 4X SCALE NOTES: 1. This installation has been evaluated for use in locations adhering to the Florida Building Code and where design pressure requirements as determined by ASCE 7 Minimum Design Loads for Buildings and Other Structures do not exceed the design pressure ratings listed herein. 2. All interior and exterior perimeter surfaces of the window must be caulked. 3. Anchors shall be specified and spaced as shown. Anchor embedment to base material shall be beyond wall dressing or stucco all, into wood or concrete. 4. Wood bucks (by others) must be engineered and anchored properly to transfer loads to the structure. 5. The responsibility for selection of Simonton Products to meet any applicable local laws, building codes, ordinances, or other safety requirements rests solely with the architect, building owner, or contractor. 6. Shims are optional. Max. shim stack is 1/4". DISCLOSURE STATEMENT This document Is the property of Simonton Windows. which retains all proprietary and other rights to its subject matter. This document is provided to the recipient on the expressed ;onditlon that it is not to be disclosed reproduced in whole o part, nor used in not with the design, manufacture or repair of goods for anyone other than Simonton Windows without its co eent. This restriction does not limit the recipients rights to utilize information contained in this document which is properly obtained from another source. Dimensional Tolerances :f SIMONTON' DRAWN B' Unless Otherwise Scecifed u' r R n o s I Cochrane Avenue T.D.D. Pennsboru, wV 26415 CHECKED Decimals Angles SCALE: [SHEET: APPRVD A d:.03 nT 1 of 1 Ax f .01 0' 30 min. SERIES: .xxx t .005 43-17 SINGLE HUNG 2x (Validator / Operations Administrator) Simonton Windows 1 Cochrane Ave. Pennsboro, WV 26415 Attn: Patricia Robison AAMA CERTIFICATION PROGRAM AUTHORIZATION FOR PRODUCT CERTIFICATION The product described below is hereby approved for listing in the next issue of the AAMA Certified Products Directory. The approval is based on successful completion of tests, and the reporting to the Administrator of the results of tests, accompanied by related drawings, by an AAMA Accredited Laboratory. 1. The listing below will be added to the next published AAMA Certified Products Directory. SPECIFICATION RECORD OF PRODUCT TESTED AAMANVDMA/CSA 101/I.S.2/A440-05 H-LC50*-914x1930 (36x76) COMPANY AND PLANT LOCATION CODE SERIES MODEL & PRODUCT MAXIMUM SIZE TESTED NO. DESCRIPTION Simonton Windows - Pennsboro, WV SIM-1 43-17 SH FRAME SASH Simonton Windows - Paris, IL SIM-2 (PVC)(O/X)(IG & OG)(INS GL) 914 mm x 1930 mm 860 mm x 937 mm Simonton Windows - McAlester, OK SIM-4 (MODIF)(REINF)(TILT)(ASTM) (3'0" x 6'4") (2110" x 3'1") 2. This Certification will expire December 8, 2012 and requires validation until then by continued listing in the current AAMA Certified Products Directory. x 3. Product Tested and Reported by: Architectural Testing, Inc. x Report No.: 87803.01-501-47 ' ;=gCOPY Date of Report: December 23, 2008 Date: June 24, 2009 Cc: AAMA JGS ACP-04 (Rev. 8/06) Validated for Certification ,h, 4L Adocited Laboratories, Inc. Authorized for Certification America rchitec ural Manu acturer Association AAMA (Validator/Operations Administrator) CERTIFICATION PROGRAM AUTHORIZATION FOR PRODUCT CERTIFICATION Simonton Windows 1 Cochrane Ave. Pennsboro, WV 26415 Attn: Patricia Robison EI The product described below is hereby approved for listing in the next issue of the AAMA Certified Products Directory. The approval is based on successful completion of tests, and the reporting to the Administrator of the results of tests, accompanied by related drawings, by an AAMA Accredited Laboratory. 1. The listing below will be added to the next published AAMA Certified Products Directory. SPECIFICATION RECORD OF PRODUCT TESTED AAMAIWDMA/CSA 101/I.S.2/A440-05 H-R50*-914x2438 (36x96) COMPANY AND PLANT LOCATION CODE SERIES MODEL & PRODUCT MAXIMUM SIZE TESTED NO. DESCRIPTION Simonton Windows - Pennsboro, WV SIM-1 43-17 SH FRAME SASH Simonton Windows -Paris, IL SIM-2 (PVC)(0/X)(IG & OG) 914 mm x 2438 mm 857 mm x 705 mm Simonton Windows - McAlester, OK SIM-4 (INS GL)(MODIF)(REINF) (TILT)(ASTM) (3'0" x 8'0") (2'10" x 2'4") 2. This Certification will expire July 27, 2013 and requires validation until then by continued listing in the current AAMA Certified Products Directory. 3. Product Tested and Reported by: Architectural Testing, Inc. Report No.: 89922.01-501-47 COPY Date of Report: September 9, 2009 Validated for Certification Ad'4-L h, 4k ocited Laboratories, Inc. Authorized for Certification Date: September 10, 2009 Cc: AAMA JGS America Architect uraI MIanu acture Association ACP-04 (Rev.8/06)