Loading...
HomeMy WebLinkAboutSUBMITTED PAPERS)0—,- D e' I Date: I Fee Due Receipt# Permit # (� / C Planning & Development Services J != Building & Code Regulations Division `SC,q� 2300 Virginia Ave. Fort Pierce, FL 34982 . ..,., (772)462-1553 CO SPECIALTY PERMIT APPLICATION ❑ Electrical Plumbing ❑ HVAC ❑ Fence ❑ Shed ❑ Demolition ❑ Gas ❑ Siding Seepage 2 for instructions and additional paperwork required for specialty permits 1. Location/Site Address: 2. Parcel ID Number: 7666 � 32 - 740 �) 0 "1 0`6(," / office flsa Only Section Township Range Map Page Zoning Ian Use Initials tt o ^,J 3. Complete Description of Project or Work: 4. Owners Information 5. Contractors Information % Name: fq /nJ Address: 7� �� / �C L, r City; , S + State: / ` Zip: 3 L/ / a Phone: 7 6 C� r� Z 7 6. Value of Construction: $ 11 / & U FL Reg/Cert #: c t)C S y County Cert#: 7 `�a / Business Name: ��A �-" &^ W/ �J So A / Phone: V6 V -V63DFax: 3! /-613 / ya•a OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done compliance with all applicable laws regulating cons d zoning/ V CC/ � .�� PRINT OWNER OR CONTRACTOR N SIGNA F OWNER OR CONTRACTOR STATE OF FLORIDA, COUNTY OF r n n I ACKNOWLEDGED BEFORE ME HIS DAY OF 20 � 0 { B7 r b CJ C) V WHO IS PERSONALLY KNOWN TO ME OR WHO HAS PRODUCED �� d=i`'0 2 %� �/ AS ID TIFICATION. " " / i/ / ' 11t ( " r rn� `� SI ATURE OF ARY TYPE OR PRINT N OF NOTARY COMMISSION NUMBER NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. EXEMPT: A/C -HEAT REPLACEMENT WITH CONTRACT UNDER $7500.00 A - Revised 04/26/2010 NOTICE TO OWNER: FAILURE I -CORD A NOTICE OF COMMENCEMENT MAC 3ULT IN YOUR PAYING TWICE FOR WROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE B ECORDING YOUR NOTICE OF COMMENCEMENT. EXEMPT: A/C -HEAT REPLACEMENT WITH CONTRACT UNDER $5,000. INSTRUCTIONS Please complete all information in the space provided. All information must be printed (use black or blue ink only) or typed. This permit application is to be used only for those activities that are not otherwise included under a primary building permit. This application may not be used for any activity that includes structural alteration. The information to be provided with this application includes: 1. Location/Site Address 2. Parcel ID Number 3. Description of Project or Work Activity 4. Owner Information 5. Contractor Information 6. Value of Construction Indicate the street address or general location of property where the building activity is taking place. Indicate the tax identification number of the property where the building activity is taking place. Fully describe the activity to take place. Indicate the name and address of the owner of the property on which activity is taking place. Indicate the State of Florida registration number (if applicable), St. Lucie County contractor license number and the name of the business doing the work. Indicate the total value of the work to take place. Total cost of construction includes all current retail material and labor costs associated with the building/construction activity. Construction value is used to determine the permit fee. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction. ❑ Gas Attach 2 piping schematics with tank size,location, and BTU of each appliance ❑ Shed: Attach 2 plot plans, 2 copies of DCA letter and plans, 2 anchor specifications ❑ Fence Attach 2 plot plans showing location of fence height of fence and type of fence ❑ Siding Attach 2 copies of manufactures specifications ❑ HVAC Attach 2 residential energy studies, 2 manual J calculations. 2 sets of duct layouts for new system or full replacement This application can be submitted to St. Lucie County Building and Zoning, 2300 Virginia Avenue, Fort Pierce, FL 34982. All permit applications must be filled out completely before submission. No applications will be accepted for processing after 4:30 P.M. For assistance in completing this application, please call (772) 462-1553, during regular office hours (8:00 AM - 5:00 PM), Monday through Friday. NOTE: Emergency electric service change out inspections will not he performed after 3: 00 PM without special arrangements and additional fee paid. Upon issuance of this permit, required inspections can be scheduled by calling (772) 462-1261. sSUMMARY INFI_—IMATION SHEET FLORIDA SOLAR ENERGY CENTER 7 October 1995 1679 CLEARLAKE ROAD, COCOA FLORIDA 32922-5703 (407)638-1000 n�C FSEC # 94009 MANUFACTURER Revised November 1995 Collector Model Sealed Air Corporation FP-48 3433 Arden Road Hayward, California 94545 This solar collector was tested by the Florida Solar Energy Center (FSEC) in accordance with prescribed methods and was found to meet the minimum standards established by FSEC. The purpose of the tests is to verify initial performance conditions and quality of construction only. The resulting certification is not a guarantee of long term performance or durability. DESCRIPTION Gross Length 3.658 meters 12.00 feet Gross Width 1.192 meters 3.91 feet Gross Depth 0.006 meters 0:02 feet Gross Area 4.359 square meters 46,92 square feet Transparent Frontal Area 4.359 square meters 46.92 square feet Volumetric Capacity 11.7 liters 3.1 gallons Weight (empty) 13.4 kilograms 29.5 pounds Recommended Flow Rate 303 ml/s 4.8 gpm Maximum Operating Pressure 207 kPag 30 psig Maximum Wind Load Not Applicable Number of Cover Plates None Flow Pattern Parallel Forced Circulation Number of Flow Tubes Multitube mat MATERIALS Enclosure None Glazing None Absorber Co -polymer plastic with UV stabilization FILE COPY Absorber Coating None Insulation None THERMAL PERFORMANCE Tested per ASHRAE 96-1980 (RA 1989) Incident Angle Modifier Kta = 1.0 - 0.08 1 _ 1 coact 1 Test Flow Rate 303 ml/s 4.8 gpm Efficiency Equations rl = 79.4 - 1596 (Ti-Ta)/I rl = 79A - 281 (Ti-Ta)/I 171 = 79.4 - 1586 (Ti-Ta)/I 617 [(Ti-Ta)/I)1 rl = 79.4 - 279 (l i-Ta)A - 19 [(Ti-Ta)/1)2 Units of Ti-Ta/I are °C / WattJmz Units of Ti-Ta are OF / Btu/hr•ft' RATING The collector has been rated for energy output on measured performance and an assumed standard day. Total solar energy available for the standard day is 5045 Watt-hours/ml (1600 Btu/tV) distributed over a 10 hour period. Output energy ratings for this collector based on the second -order efficiency curve are: Collector Temperature Energy Output Low Temperature, 35°C (95°F) 46,900 Kilojoules/day 44,500 Btu/day Intermediate Temperature, 50°C (122°F) 20,800 Kilojoules/day 19,700 Btu/day High Temperature, 100°C (212°F) 0 Kilojoules/day 0 Btu/day Property Appraiser - St.Lucie r-linty, FL Page 1 of 1 PROPERTY RECDRD CARD Anthony Melein Record: 1 of 1 <<Prev Next » Spec.Assmnt Taxes Exemptions Permits Home Print Property Identification ��UCIECoG� Site Address: 7666 Greenbrier Cir ParcellD: 3322-700-0046-000-1 Sec/Town/Range, 22 :36S :39E Account # 149672 Map ID 33/22S Zoning: PUD Land Use City/Cnty: SF Res St Lucie County Ownership and Mailing Legal Description Owner Anthony Melein Elisabeth Melein POD 19 PUD II GREENBRIER (PB 41-5) LOT 41 (OR 3203-906) Address: 7666 Grennbrier Cir Port St Lucie FI 34986 Sales Information Assessment 2010 Final Total Land and Building Date Price Cnde Deed Book/Page 2010 Final 199900 Land Value: 52000 Acres 0.17 5/10/2010 150000 0112 SP 3203 / 0906 Assessed: 199900 Building Value 147900 12/17/2009 100 0112 CT 3166 / 2580 Ag.Credit: 0 Finished Area 2156 SgFt 5/21/2004 226500 00 SP 1977 / 2986 Exempt: 4/21/1998 21320600 02 WD 1140 / 1945 Taxable: Taxes. 4154.76 BUILDING INFORMATION Exterior Features View RoofCover CT - Conc Tile RoofStruct: HP - Hip ExtType HB - HB YearBlt 2004 Frame. Grade B - B EffYrBlt 2004 PrimeWall BS - CB Stucco StoryHght 0010 - 1 Story No.Units 1 SecWall Interior Features BeclRooms: 3 Electric: MX - MAXIMUM PrmintWall. DW - Drywall FullBath 2 HeatType FHA - FrcdHotAir AvgHUFI: STD 1/2Bath: 0 HeatFuel: ELEC - Electric Prm.Flors: CT - Tile -Ceramic %A/C: 100 %Heated: 100 %Sprinkled: 0 Special Features and Yard Items Land Information Type Y/S Qty. Units Qual Cond YrBlt, No Land Use Tvpe faeasu Cr; n' 1 0100-SF Res BI -Site 1 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED http://www.paslc.org/prc.asp?preIid=332270000460001 12/28/2010 DETAIL 1 COUPLING HOSE SEALED AIR PART # 3825 FRAMELESS COLLECTOR ❑SE. ST DETAIL 2 THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH k+WWWW 19 TIE -DOWN SEALED AIR PART # 3550 i/4'X 2-1/2 LAG SCREW NYLON STRAP 5/8'SEALED AIR PART # 4360 STAINLESS CLAMP SEALED AIR PART # 3325 CONCEALED FASTENERS OR ATTACHIMS ARE THE RESPONSIBILITY OF THE CONIWOROF RECORD AND TIE -DO ASSEMBLY 1 /4' X 2-1/2' LAG BOLT 8T. LUCIE CO BUILDING DIN REVIEWED BY DATE MUST 0 KEPT ON JOB OR NO INS CTION WILL BE MADE WOVEN NYLON STRAP WITH DOUBLE CLOVE KNOT .,— TIE DOWN ROOFING MATERIAL DECKING TRUSS OR RAFTER HEADER PTPF CTUBE) MAT ABSORBER PLATE DETAIL O\ REINFORCING RING PP SERIES COLLECTER CROSS SECTT❑N FBC2007 W/2009 Amendments MODEL FP-48 I FP-40 I FP-32 SIZE 3, 94' x 12' 3, 94' x 10' 3. 94' x8' ENERGY OUTPUT 2 95DEG. F (BTU) 44, 500 36 800 29, 400 FP —SERIES IS AN UNGLAZED COLLECTOR WITHOUT FRAME REFERENCE FLORIDA SOLAR ENERGY, CENTER REPORT NOS. 94009,95020C AND 95019C, STATIC PRESSURE TEST 13Y ENTESTING INC, TEST REPORTTRNOS. HETI-03-1363GANDDHETI-03-1364 STRAP SPACING, CHART MAX ELEVATION 25.FT. BUILDINGS UNDER 60 FT. HEIGHT W I ND STRAP SPACING L IN- > STRAP FOR 1/2' SPACING 0. S. C IN. B. SPEED FOR 5/8' PLYWOOD (100 32 32 100 32 32 110 3C 30 in 28 30 140 24 24 142 24 L J um 0 Jz a C5 U d C `\ LJ L 20 - ASSEMBLY - �NQAL TIE DOWN ASSEM CASTER PLAN"'i8 1� 155 �ILEi Rf NOTE: IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ,< ^�;,, .: FPII2003F FIL DETERMINE THAT MATERIALS, INSTALLATION AND ASSEMBLY ;'_., ON FULLY COMPLY WITH THE LATEST REVISION OF THE FLORIDA SHEET BUILDING CODES 1 - Jan 2007 2 SHE STRAP SPACING PER SCHEDULE ON SHEET 2 ciI I p � � I c� bow 0 N 3 a v DETAILI SHEET 2 --47 1/4• —47 1/4 —47f 1%4• —47 1/4' -+ TYPICAL PLAN SEALED AIR FRAMELESS SERIES SOLAR COLLECTOR MODELS FP-32, FP-40, FP-48 f^rll 1 rP rr-IM Ann - OL IPPLY NE 11 PLUMBING DIAGRAM CUP13LYMER PLASTIC U. V. STABILIZED. S DETAIL SHEET vern..0 — "1 .ter.. TYPICALrR00F SPLIT SYSTEM LINE MULTI -BANK SYSTEM Y O 3 c F-- Co U O Q CC a O a ¢ C.>t Zca _ Z t »' Z'UO3C>_ W C13 --i :m O� W ui Q , 2 o Q to cis TYP, ) S. SCHED.40 IC PIPE J E�'� �. €CE�FiyPi�1►I NJ a �• a, iD DES{rxD ,r',dDR:nA s7s. a �, )sc0lls . !: 7 APPROVED AS DESIGNED SI GNED: a Ir 0 U vlw�= ZJC7U Q G1 J Q Pn0_L9Q�-W �0_xmF-Q p P W Z_W> WL7ZY0 !-Q(nQWO.. QUW0�SO_ =v)==U Q FILE, REF -PM2003. G SHEET 1