Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSOFFICE!JE ONLY Date: . 0-/I ALL St. Lucie County Building and Zoning. 2300 Virginia Avenue Ft. Pierce, FL 34982-5652 By 772-462-1553 f, LUCie County/ APPLICATION FOR ALUMINUM STRUCTURES PERMIT PROJECT INFORMATION 1. LOCATION/SITE ADDRESS: Der ' - is 2. PROJECT NAME: a\Jey, r ^. SITE PLAN NAME: 3. PROPERTY TAX ID #: 3 2"z-�.b� rI — D C)C) " 3 4. LEGAL DESCRIQ ION (attach extra sheets if necessary): eD6iz:Gno 5110(2S—pV)As< TVJ O^ L4* 4rl 5. PLAT - 6. PAGE 7. BLOCK 8. LOT rf BOOK NO. NO. NO. ((�� 9. PARCEL SIZE: ACRES/SQ FT. LOT DIMENSIONS 'IR 73 1- 1/S A 6IS X 11S 10. SETBACKS (ACTUAL) FRONT: Id '� BACK: - RIGHT SIDE: LEFT SIDE: 0 11. TYPE OF STRUCTURE (CHECK ALL APPROPRIATE BOXES FOR EACH AND EVERY TYPE OF STRUCTURE) TYPE OF CONSTRUCTION N=New A= Addition R = Rebuild SG = Slab on Grade SR = Raised Slab WD = Wood Deck DIMENSIONS SQUARE FEET OF CONSTRUCTION I SCREEN ROOM , ❑ NEW IX EXISTING i I X 24 2 8S ❑ CARPORT/PATIO ROOF ❑ NEW ❑ EXISTING X ❑ HABITABLE GLASS ROOM ❑ _ NEW ❑ EXISTING X ❑ SUNROOM ❑ NEW ❑ EXISTING X ❑ SHED ❑ NEW ❑ EXISTING X ❑ 'POOL ENCLOSURE ❑ NEW ❑ EXISTING X ❑ M H ROOF OVER ❑ NEW ❑ EXISTING X ❑ ROOF SYSTEM OVER EXISTING ACCESSORY STRUCTURE ❑ NEW ❑ EXISTING X ❑ OTHER: ❑ NEW ❑ EXISTING X ❑ POOL FENCE Linear feet TOTAL SQUARE FOOTAGE OF CONSTRUCTION 12. VALUE OF CONSTRUCTION: $ 31 S O D C 11 The value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction activities. If the value is $2500 or more, a RECORDED Notice of Commencement must be submitted PRIOR TO FIRST INSPECTION. SLCCDV Form No.: 001-02 Rev. 31112009 OWNER INFORMATION NAME: n._ cL'_D bJ!X� n L% ADDRESS: t^_5l 0 LQ�ery� U� Gib CITY: i - C e STATE: ZIP 3r lrq ,51 PHONE (DAYTIME): (_) EMAIL: FILL IN NAME AND ADDRESS BELOW IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE: FEE SIMPLE TITLEHOLDER: ADDRESS: CITY: STATE: ZIP PHONE (DAYTIME): (_) CONTRACTOR INFORMATION STATE OF FLORIDA REGJCERT #: CL C 21 Z * g3 ST. LUCIE COUNTY CERT #: a --q 3 Q BUSINESS NAME: IKsT *�11flY1inUM orviG--� LLL Aba -rFe Phrb l r(A QUALIFIER'S NAME: IBC -fit'-- 6rann C J ADDRESS: _4-onLy Ka n"" Qjaje, r� CITY: -t i+. I e-1,7t _tom STATE: r-7 L— ZIP 3 � PHONE (DAYTHVIE): ( ) 419640222. FAX NO. �&5-3252 email: G1dMtr�!a�{ InCLbrC�l'�dG •l ARCHITECT/BNGWEER: N SCO G a O-L<e-e- j ADDRESS: 'B Dx .-2,5 '7 5 rI rl J CITY: �_�fA I�SVO I e STATE: {' L 21P 23 2- 0 36 PHONE (DAYTIME): NOTE: IF APPLICABLE, SUBCONTRACTOR AGREEMENTS MUST BE ATTACHED TO APPLICATION FOR ROOFING, ELECTRIC, PLUMBING, AND HVAC ZONING REQUIREMENTS All such structures will be subject to the requirements of the ST. LUCIE COUNTY LAND DEVELOPMENT CODE. ❑ 2 scaled plot plans showing lot size, dimensions of existing host structure, and proposed aluminum addition. All setbacks including front, side, rear and distance between adjacent property structures in MH Parks shall be indicated on the plot plan. ❑ 2 sets of color photos for all storm damaged areas to be reconstructed. One picture must include house address number -for - inspection verification. ( not required for construction unrelated to storms) SECTION J� TOWNSHIP RANGE MAP NO. p Additional ZONING (/` f` f LAND USE I/� LOT CVG % .� Pets 1 lua4uacu BIMS FEE $ MISC FEES TOTAL FEES CODEMIN EDATF..1 FRONT PLANS VALUE OF CONSTRUCTION COUNTER ZONING SUPERVISOR EXAM EMIN R VEGETATION USING ICC TABLE . „ 110_i1 PLAN k VIEW SPECIFICATION CHECKLIST PLEASE PROVIDE ONE OF THE FOLLOWING: 'd 2 Sets of Detailed Plans: Dated, Signed & Sealed by an Engineer or Architect holding a Florida State professional license. ❑ 2 Sets of Detailed Plans: Designed in accordance with the AAF Guide To Aluminum Construction in High Wind Areas. ❑ 2 Sets of Detailed Plans: Designed in accordance with any Approved Manual per fs-489.113. (1) ANY PLANS SUBMITTED WITHOUT COMPLYING WITH THE FOLLOWING SHALL BE RETURNED WITHOUT APPROVAL. ALL PLANS MUST BE IN INK AND ANY NOTATIONS IN PENCIL WILL NOT BE CONSIDERED A PART OF A SUBMISSION. • All plans must belegible and must be designed in Architect's Scale on pages which are 81/2" x 11" or larger. • All relevant tables & details, if using a manual, must be properly highlighted and must match design checklists & drawings. • The plan view must include all dimensions; the location of the host structure and all materials must be sized and identified thereon. • All elevations must be shown, including 4`s wall detail, dimensions and all material must be sized and identified. • All primary and secondary carrier beams, spans, spacing, gauges must be shown [Example: T x 8" x .072"]. • All methods of fastening or other details which are relevant to the design must be identified on the Plans. • All upright column heights, sizes, spacing and gauges must be shown as follows: [Example: 3" x 3" x .050"]. • All chair -rails, roof purlins, gins, channels, knee -bracing, k-bracing, cable bracing or any other required component must be sized and identified. • All ridge beams and super gutter or fascia attachments must be identified. • All roof pans or composite panels, with gauges and spans, must be sized and identified. • All footing, slab and ISO pier designs must be on the plans, per the Architect / Engineer's plans & specifications.. • All light metal alloys which are utilized shall be designed in conformity with the Florida Building Code of 2007, Chapter 20, including 2006 revisions. • Barrier railings, if utilized, shall have all materials, fasteners and height specified and shall have self -closing, self - catching gates with picket spacing. (II) SITE CONSTRUCTED SHEDS, HAVING ANY ALUMINUM COMPONENT, SHALL MEET ALL OF THE ABOVE REQLTIREIVIENTS AND THE FOLLOWING ADDITIONAL ITEMS: (A) 2 copies of the current product approval [i.e. N.O.A. or State of Florida approval] with the proposed "opening" or cladding component highlighted and with fasteners and design pressures, per FBC 1714, clearly identified. (B) 2 electric schematics, in accordance with the N.E.C., if applicable. (C) Design pressures, per ASCE-7, identified on the openings of all Plans. (III) HABITABLE ROOMS/ADDITIONS DESIGNS SHALL MEET ALL OF THE ABOVE REQUIREMENTS, EXCEPT AAMA SPECIFICATIONS, AND CHAPTER 13 OF THE FLORIDA BUILDING CODE. (IV) SUNROOMS (as defined in R202 and FBC 2002.6) MAY BE CONSTRUCTED, SO LONG AS THEY MEET ALL OF THE ABOVE REQUIREMENTS AND MUST BE IN STRICT COMPLIANCE WITH AAMA/NPEA/NSA2100.02 AND MEET THE FOLLOWING ADDITIONAL ITEMS: (1) The designer or engineer will state on all Plans, which Category of Design [3.1.2] will be used, inclusive of the definition. (2) If designing a Category 4 or Category 5 structure, as defined in the current Edition of 3.1.2.4 and 3.1.2.5, proper energy calculations and long form equipment sizing calculations shall be required, pursuant to Chapter 13 of the current State of Florida Building Code. (V) MOBILE HOMES (FAC 15C-2.0081 - PAC 15C-2.0072): ALL STRUCTURES ADJACENT TO OR NEW ROOF SYSTEMS (Pan or Composite) OVER EXISTING ADJACENT STRUCTURES TO A MOBILE HOME SHALL REQUIRE: (a) A 4`s wall or a current, signed original manufacturer's attachment approval letter which includes the model number, serial number and current owner's name and street address. (b) That the complete guide to H.U.D., specifications be strictly adhered to. (c) A Certif ed Florida Engineer may design the manner of attachment of the proposed structure to the host house but shall assume full responsibility for both structures' integrity by site specific documentation. AFTER RECORDING -RETURN TO: PERMIT NUMBER: JCS Parch tmtagt&Y 4006 Mariah Circle Fort Pierce, FL 34947 JOSEPH E; �",,TH. CLERK OF THE CIRCUIT COURT SAINT LU( ;OUNTY - LE _ 1_643z_: 'r. 17 _o H0 at 10:46 ,A p� Coc Type NC ;R CAE :c.:. ,v oa NOTICE OF COMME The undersigned hereby given notice that improvement will be made to certain real property, and in. accordance with Chaptef 713, Florida Statutes the following information is provided in the Notice of commencement. 1. DESCRIPTION OF PROPERTY (Legal description and street address) stet,,3,unben TAX FOLIO NUMBER: SUBDIVISION CK�TRACT LOT q.7 .. UNIT 67%1Toli11A 2. GENERAL; DESCRIPTION OF IMPROVEMENT: sC eey /tea Re 3. OWNER`.INFORMATION: a. Name: Tom M,-y 40Wc k b. Address: 3 cst-(Al) Q'eYCiiZ c. Interest in�property:, f7h, li(�ft� d. Name and Address of fee simple titleholder (if other than owner) 4. CONTRACTOR'S NAME, ADDRESS AND PHONE NUMBER: IZS,T 'Pow �+oru `t LRZO Ma.rkl I't i rc>ge, °4-,_P(ewce 5. SURETY'S NAME, ADDRESS, AND PHONE NUMBER AND BOND AMOUNT: 6. LENDER'S NAME, ADDRESS AND PHONE NUMBER: -�{U,(`y^V1v/�.i�YlwyL C- e�rJk-e-esa d%:;,a 11 ✓7 hhe, 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13 (1) (aa)7., Florida Statutes: AMEE, ADDRESS AV PHONE NUMBER: ii %� 5i�C fs /i3od��rl �rnomy Jd/ 6ofQ 8. In addition to himself or herself, Owner designates the following to receive a copy of the Lienor's Notice as provided in Section713.13 (1) (b). Florida Statutes: NAME, ADDRESS AND PHONE NUMBER: 9. Expiration.date of notice of commencement (the expiration date is 1 year from the date of recording unless a different date is specified) 20 WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENTARE mlw L-o tc e,2 Signatur o wrier or �' Print Name and Pr vide Signatory's Title/on9 - Owner's thorized Officer/Director/Partner/Manager State of Florida County of Sr LvG / e The Foregoing instrument w_�as acknowledged before me this day of ��e��17�E/�20 n�. By: -Tomm-1 i (Nam of Person) FL, p��ro�g (Type ut I ... e.g. wrier, officer, Trustee, attorney in fact) 3 D v A� ROBIN SECOR ®� Notary Public, State of Florida (Printed Name of Notary Public) (Sig ature otary'Public) 00mmission#0629169 My Comm, axplres Jae, 15, 9011 Under penalties of perjury, I declare that I have read the foregoing and that the facts in it a "!_� d belief (section 92.525, Florida Statutes). Sig ature(s) of Owner(s) Owner(s)' Authorized Officer/Director/Partner/Manager who signed above: 4e- By: T� MM v V. Lowe ice( CERTIFICATION: This application is hereby made in order to obtain a permit to do the work and installations as indicated, and to obtain a certificate of capacity, if applicable, for the permitted work. NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE TO APPLICANT;.... IN THE EVENT IT IS NOT YOUR RIGHT TITLE OR INTEREST THAT IS SUBJECT TO ATTACHMENT, THE APPLICANT DOES HEREBY MAKE A GOOD FAITH PROMISE TO DELIVER A -COPY OF THE ATTACHED CONSTRUCTION LIEN LAW NOTICE TO THE PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT, AND DOES SO AS .A CONDITION PRECEDENT TO THIS PERMIT 1. If utilizing the AAF Guide to Aluminum Construction in High Wind Zones, I the Contractor/Owner Builder hereby certify that the components being used, fasteners type and fastening pattern meet all the requirements for the designated wind zones established by the county and take full responsibility for complying with the submitted design of the structure being permitted. 2. I further certify that all the foregoing information is accurate, that no work or installation has commenced prior to the issuance of a permit and that all work shall be performed in compliance with all applicable laws regulating construction and, zoning in this jurisdiction. I understand that separate permits may be required for ELECTRICAL, and HVAC, etc., not otherwise included with this building permit application. 3. I , the Contractor / Owner Builder, have verified that the existing foundation meets the requirements of the Engineer of Record and is in adequate condition to withstand the uplift and weight of the aluminum structure and said structure will not e c l the9kotprint�of the structure that was in exostence prior to remov�y the storms. SIGNATURE STATE OM COUNTY OF The foregoing instrument was acknowledged before me me thiis 2-0daffy Of � , 20 00 , � by Ao* 111cnde,6rQ n who is personally known ✓ to me, or who has produced as id ' ication gignana of Notary IMPORTANT • R. mft We 6Y FICA to ` R*MV A41KMON $t MY C,0 P1Yt4 f4W ®WWO STATE OF'I COUNTY OF The foregoing instrument was acknowledged before me me this k dayoff� by Mw who is personally known -I./ to me, -or who has produced as Raymond Atkinson My commission DD918265 Expires 0812312013 y TWO (2) SIGN - � __ •� � � � - ACH SIGNATURE MUS L'O D. IF APPLYING FOR THIS BUILDING PERMIT AS AN OWNER/BUILDER, THE OWNER MUST PERSONALLY APPEAR, IN THE OFFICE LISTED ON THE FRONT OF THE APPLICATION, TO SIGN THIS APPLICATION & THE OWNER/BLDR AFFIDAVIT. • ALL SIGNATURES ON APPLICATION SUBMITTED SHALL BE ORIGINAL, SIGNED IN INK. COPIES, FAXES, OR STAMPED REPRODUCTIONS ARE PROHIBITED. • WHEN A PERMIT IS AVAILIBLE FOR ISSUANCE BUT IS NOT PICKED UP WITHIN THIRTY (30) DAYS AFTER NOTIFICATION OF AVAILIBILITY, IT WILL BE VOIDED. IF THE APPLICATION IS RESUBMITTED, AN ADDITIONAL FEE WILL BE CHARGED. vg 5(-S.f i "Foof"L : p4o��tjff ON W VTA]rf' EMMENT \� viip, j 1" .1 . Will 0 � � 0� DD A 3, Ur.4. DESCRINION WAS PRCMDED BY COWT /A 4. L*42,401A 110=0MAL AWUV--V I ;W WOW N3 to- 2 lW.o%Foo,,v*r x WS LOT F0. IN V LOT 428 BCALE T-W A-10.2 Al?0- 5y PLAr 2 10mr, 7V6-F' FOT j' E)2O . ICMIFS't-BoAf Bmto i'o""EA PIAT ST. CC DIG DIVISIGi� OFq2xF,MR 14 CF'ED FOR CO; Ir IN CE B lie LANSANIPE1 T MUST BE KTPT 6NJOR OR NO V SPLCTION NVILL BE MA' DE. —p .oR.,oFn)y SJOR, HA 0 ny THE' *REOF RECORDED IN PLAT BOOK 43 PAGES T3, 33A—E THE T E PLAT M E 8LIC RE -CORDS OF ST, LUCIE COUNTY,- ALORMA. MM Maw -#E m6viwi A)DRESS: MEW O aaerWN &Tmmmm Audn 5WycwuE tlaI'ANT To 16ftnMrA 1M ... . . .. . .............. ...... ...... . .. ......... ALUMINUM SCREEN ENCLOSURE DESIGN PROJECT NO. DA10-378 DRISCOLL ENGINEERING, INC. PO BOX 357577 Gainesville, Florida 32606 1- NAME: LOWERY (352) 331-1513 CA. 8690 2- LOCATION: 5663 SUNBERRY CIRCLE FT PIERCE, FL 3- DESCRIPTION: SCREEN ENCLOSURE 4- CERTIFICATION I hearby certify that the accompanying aluminum design for the Lowery screen enclosure & wood deck as referenced above, demonstrates compliance with the 2007 Florida Building code Chapter 20 and the 2009 amendments to chapter 20 of the F.B.C. 2007 to the best of my knowledge. Project wind load information 1. Basic wind speed = 140 MPH 2. Wind importance factor table 2002.4 3. Wind exposure for this design is exposure C 4. Interior pressure coefficient or Gcpi = 0.0 5. Design pressures are per table 2002.4 of the 2007 FBC. Screen Roof 21.9 PSF Screen wall 6.1 PSF GENERALNOTES 1. All aluminum extrusions shall be assembled and attached in accord with the manufacturer's specifications and requirements, And with the attached engineering design for wind speeds of up to 140 miles per hour. The more stringent requirements of the two shall be used. All aluminum extrusions shall be 6005-T-5 aluminum alloy (U.N.O.) 2. Any existing structures to which the screen enclosure and/or solid roof structure is to be attached shall be structurally sound and of adequate structural integrity to support the fully loaded screen enclosure or solid roof. The loads imposed by those structures are provided on sheet 2 of 4 If the structural integrity of the existing structure to support the superimposed loads is in doubt, It shall be the responsibility of the homeowner and / or the contractor to retain services of an architect or engineer licenced to practice in the State of Florida to field verify that the existing structure is capable of supporting the required loads. 3. Any connections of aluminum structures to the fascia of existing structures shall be limited to roof overhangs of 24" or less, unless noted otherwise (U.N.O.) 4. All aluminum structures with elite roofs & screen enclosed roofs and walls, as referenced herein, are designed as closed structures in accord with FBC 2007, Chapter 20. & the 2009 amendments to Chapter 20 of the 2007 F.B.C. 5. A mean height of 30 feet used and screen cloth size of 18X14x0.013 mesh any changes the engineer shall be notified. 6. All fasteners shall be aluminum, non-magnetic stainless steel, cadmium plated steel, ceramic coated zink 7. Minimum edge distance between exterior frame ( screen walls) and the edge of supporting slab and / or footing shall be 2" 8. All fasteners use to attach aluminum frame members to concrete slab and/ or foundation shall be simpson titan ( or equal) 1/4" dia.. 2" min embed into concrete, embedment anchors shall be placed amin of 3" from edges. 9. Contractor is responsible for protecting aluminum structure from dissimilar metals. 10. All primary members shall be connected with bolts, pop rivets, or other positive fasteners. 11. It is the contractors responsibility to maintain all critical edge & end distances as required for all fasteners, anchors etc.. CONCRETE CONSTRUCTION NOTES 1. Concrete work shall conform to "Building Code Requirements for Reinforced concrete" (ACI-318) and "Specifications for Structural Concrete (ACI- 301), Latest edition. 2. Concrete mix "A" shall be used for foundation walls, footings,and exterior slabs on grade. the following spec's apply to the concrete mix design. All concrete mixes shall contain a water -reducing admixture conforming to ASTM C-94. All air -entraining admixture shall conform to ASTM C-260. (See sheet 2 for concrete mix A) 3. All concrete shall cure for a minimum of 28/ days. If forms for vertical surfaces are removed prior to the end of the curing period, spray surface with liquid membrane curing compound. 4. Reinforcing steel shall conform to ASTM A615, GRADE 40 (fy=40ksi). Lap contiuous bars for tension lap splice per ACI-318 U.N.O. Provide corner bars of same size as horizontal reinforcement. Cover for concrete reinforceing steel shall be in accordance with ACI-318 paragraph 7.7. 5. Welded wire fabric (WWF) shall conform to ASTM A-185. Lap sheets on mesh space and wire tie adjacent sheets together Cut alternate reinforcement at control joints. 6. All slab on grade shall have construction or control joints not to exceed 12'-0" spacing U.N.O. 7. Electrical conduit and other pipes to be embedded in structural concrete floors slabs or walls shall be placed in accordance with the requirements of ACI-318, paragraph 6.3. FOUNDATIONS 1- Foundation concrete to have a minimum of 28/ day compression strength of 3,000 p.s.i. steel reinforcement to be min of (1) #5 rebar cont. Grade 40 having a minimum splice of 30" at all locations, In absence of geotechnical information, this foundation design is based on an allowble bearing capacity of 1,500 psf. Minimum slab thickness for aluminum enclosure shall be 4 inches with 616 1 0x1 0 wwf in accord with F.B.C. 2007 2- Foundation for exterior load bearing walls: Monolithic- type construction with a minimum of 8"H x8"D with (1) #5 continuous REFER TO PLANS FOR FOUNDATION SIZE & LOCATION WINDLOAD ANALYSIS PREPARED BY DRISCOLL ENGINEERING,INC. CONSULTING ENGINEERS PO BOX 357577 CA 8690 GAINESVILLE, FL. 32606 PH (352) 331-1513 PREPARED FOR CLIENT & LOCATION: LOWERY 5663 SUNBERRY CIRCLE FT PIERCE, FL DA10-378 DATE: 12-20-10 CONTRACTOR: R+T ALUMINUM SERVICES 4006 MIRIAH CIRCLE FT. PIERCE, FL (772) 465- 6772 INDEX SHEET 1: COVER SHEET, WINDLOAD ANALYSIS, GENERAL NOTES SHEET 2: WINDLOAD PRESSURES CHART, LOADS & PROFESSIONAL SERVICES SHEET 3: PLANS SHEET 4: DRAWING DETAILS PLANS HAVE BEEN PREPARED IN COMPLIANCE ITI4� " THE 2007 FLORIDA BUILDING CODE CHAPTER 20 AN���11w THE 2009 AMENDMENTS TO CHAPTER 20 \ THIS IS A SITE SPECIFIC WINDLOAD ANALYSIS ���•��,�CENBF►•.�ts'� �� MAY NOT BE COPIED OR REUSED FOR ANY PURPOSE * No 439 r * - ST c MICHAEL E: DRISCOLL F -E. / �` \\�\O FL REG. 0431322 [ 2' DESIGN WINDLOAD PRESSURES FROM TABLE 2002.4 OF THE 2007 FBC EXPOSURE (B OR C) DESIGN PRESSURE (PSF) CIRCLED NUMBERS USED FOR WINDLOAD CALCULATIONS BASIC WIND SPEED M.P.H. 100 110 120 130 40 150 B C B C B C B C B CO B C WALLS HORIZONTAL PRESSURES 12 17 13 18 15 21 18 25 21 29 24 33 ON WINDWARD SURFACES HORIZONTAL PRESSURES 10 13 10 14 13 17 14 19 15 23 18 27 ON LEEWARD SURFACES ROOFS VERTICAL PRESSURES 3 5 4 5 4 6 5 7 6 8 7 9 SCREEN SURFACES VERTICAL PRESSURES 10 14 11 15 13 18 15 21 17 24 20 28 SOLID SURFACES COLUMN REACTIONS PROVIDED AS FOLLOWS, MAIN & END (SEE DRAWING L-1 FOR LOCATIONS OF WALLS) %/AI I IFC RFI nIA/ APT: RFAr:TI111%I n;= r`nt I IRAN I r)AIIC r1M ;:nl IAInATInKI MAIN COLUMN WALL DRAWING L-1 REACTION LOADS UPLIFT I COLUMN END VIEW LATERAL GRAVITY FMOMMI FOUNDATION AREA , T-1 GRAVITY & UPLIFT LOAD MAIN COLUMNS 240 LBS EA. LATERAL LOADS MAIN WALL COLUMN 1314 LBS GRAVITY & UPLIFT SIDE WALLS 128 LBS EA LATERAL LOADS SIDE WALLS 657 LBS PULL OFF FROM HOST 132 PLF GRAVITY & UPLIFT LOAD A HOST 230 LBS EA * LOAD APPLIED TO HOST CONCRETE MIX A ULTIMATE COMPRESSIVE STRENGTH A 28 DAYS 3000 psi. SLUMP RANGE 4"+/- 1" MAXIMUM AGGREGATE SIZE V ENTRAINED AIR NONE DRY WEIGHT PER CUBIC FOOT 150 # IT-2 T-1 PROFESSIONAL SERVICES DRISCOLL ENGINEERING, INC. PO BOX 357577 Gainesville, Florida 32606 (352) 331-1513 C.A. 8690 PLANS AND SPECIFICATIONS The plans and specifications presented herein are only for the anticipated construction at the locations shown. If constuctlon plans change, the Design Professional should be notified so the plans and specifications can be re-evaluated. The Design Professional should be given the opportunity to review final plans and specifications to see if the intent of the plans and specifications has been followed and/or if supplement details and recommendations are needed. The Design Professional warrants that the plans and specifications contained herein, have been prepared in accordance with generally accepted professional engineering practice. No otherwarranties are Implied or expressed CORPORATE PROTECTION It is understood and agreed that the Design Professional's Basic Services under this agreement do not Include project observation or review of the Contractors preformance or any other construction phase services will be provided by the client. The client assumes all responsibility for Interpretation of the contractors documents and for construction observation and supervision and waives any claims against th Design Professional that may In any way connected thereto. In addtlon, The client agrees, to the fullest extent permitted by law, to Indemnify and hold the Design Professional harmless from any loss, claim or cost Including reasonable attorney's fees and cost of defence, arising or resulting from the performance of such services by otherperson or entities and from any and all claims allsing from modifications, clarifications, Interpretations, adjustments or changes made to contract documentsto reflect changed field or other conditions, except for claims arising from the sole negligence or willful misconduct thereto. OWNERSHIP OF INSTRUMENTS OF SERVICE All reports, plans, specificatlons, computer files, field data, notes and other documents and Instruments prepared by the Design Professional as Instruments of service shall remain property of the Design Professional. The Design Professional shall retain all common law, statutory and other reserved rights, Including the copyright thereto. DEFECTS IN SERVICE The client shall promptly report to the Design Professional any defects or suspected defects In the Design Professionals work or services of which the client becomes aware, so that the Design Professional may take measures to minimize the consequences of such defect. The client warrants that he or she will Impose similar notification requirements on all contractors in his or her client/contractor contract and shall require all subcontractors at anylevel to contain a like requirement. Failure by the client's contractors or subcontractors to notify the Design Professional, shall relieve the Design Professional of the cost of remedying the defects above the sum such remedy would have cost had prompt notification been given. Inasmuch as the remodeling and/or rehabilitation of an existing building requires certian assumptions be made regarding existing conditions, and because some of these assumptions may not be verifiable without expending additional sums of money or destroying otherwise adequate serviceable portions of the building, The client agrees, to the fullest extent permitted by law, to Indemnify and hold the Design Professional harmless In any claim, liability or cost ( Including attorney's fees and cost of defense) for injury as economoc loss arising out of professional services provided under this agreement, except only those damages, liability, or cost attributable to the sole negligence or willful misconduct of the Design Professional. ALUMINUM SPECIFICATIONS MAJOR AXIS BENDING ALLOWBLE STRESS Fbx (ksi) MAJOR AXIS BENDING ALLOWBLE MOMENT MaxFbxSx (in. -kips) BEAM SIZE T, T, BEAM TYPE BEAM MATERIAL 1,,x 2,, .044 .044 OPEN BACK 6063 T-6 ALUMINUM ALLOY " ^ .090 .090 PATIO SECTION 6005 T-5 ALUMINUM ALLOY .070 .070 PATIO SECTION 6005 T-5 ALUMINUM ALLOY .110 .050 SELF MATING BEAM 6005 T-5 ALUMINUM ALLOY 7.5 7.3 .116 .050 SELF MATING BEAM 6005 T-5 ALUMINUM ALLOY 8.2 12.2 t"X .120 .060 SELF MATING BEAM 6005 T-5 ALUMINUM ALLOY 8.2 15.7 .120 .055 SELF MATING BEAM 6005 T-5 ALUMINUM ALLOY 8.2 20.1 224 .072 SELF MATING BEAM 6005 T-5 ALUMINUM ALLOY 13.8 64.8 .224 .072 SELF MATING BEAM 6005 T-5 ALUMINUM ALLOY 15.4 107 2"X1 0" .389 .092 SELF MATING BEAM 6005 T-5 ALUMINUM ALLOY 15.4 3"x 3" .125 .125 1 PATIO SECTION 6005 T-5 ALUMINUM ALLOY ```�Q, 4"x 4" .125 .125 PATIO SECTION 6005 T-5 ALUMINUM ALLOY ALUMINUM PROPERTIES CAN BE FOUND IN THE ALUMINUM DESIGN MANUAL MICHAEL E. DRI6C0L.L P.E. FL REG. 0431322 / ,DWgRO A IN . W W 2 fq 00 W co ,J U� L.L Q U� W LL M W D 1. f F— W(nW_ 3 IX O t1 LID LL. O 0) 00 M Q U r U � z' u W" Z W CN Z_ v W u a Z W �U, u L' 10 1= 7 lt,...�jc�n J O tA N 110 ILL M Z x u i tU O m ` aw Z ul Zrn 6 O a a¢ y WQ J w¢ 3 DRAWING NOT TO SCALE DO NOT COPY OR REPRODUCE THESE DRAWINGS OR DETAILS DRAWINGS & DETAILS ARE FOR SITE SPECIFIC ENGINEERING ONLY 2"X 2" i� 2"X 7' N I 2"X 3" 2"X 3" X 0.070 DIAG. 6"X B" THICKENED CONCRETE SLAB ROOF BRACES (TYP) WI 1 #5 BAR CONT. 24'-1" PLAN VIEW ----------------- •----------------- ------------------ ------------------ N 2"X 3" 1"X 3" 2"X 5" 2"X Y' w 1 "X 2" 2"x 2" x 0.090 K-Braces (typ) 1 ELEVATION WALL SPACING SAME AS BEAMS HOST STRUCTURE AREA 140 MPH EXPOSURE (C) 1/2 MANSARD ROOF EUft }/ATE:11-8-10 • C) � = FOR�QL�Q LYSI$�L'i i MICH LOLL FL REG. 043922 i MATE OF : �.41V A ~M LU w cn 00 ti W m J U� rY Q U� � J W LL co }.0 z W U) W 3:cy)CL O OLoL~L a U CO fb Z L',T 1 V Lu T Z Lu M Zlo�_Lo R W Z 5.. Z w J� J I.- U. p N �w �� U Z u 00 z � a(D (2) YX 2' X 1/B' ANGLE BRACKETS PRIMARY CONNECTOR TO CONCRETE ATTACH TO BEAM W/3 #12 SMS ITW SCOTS TAPCON 114' DIA 2• EMBED EACH SIDE OF COLUMN EXISTING TRUSS INTO CONCRETE (OR EQUAL) PRIMARY CONNECTOR TO CONCRETE 2' MIN ITW SCOTS TAPCON 1/4' DIA 2' EMBED " INTO CONCRETE (OR EQUAL) i 3" MIN PAVERS •• '• •0, 4' CONCRETE SLAB (TYP) ' # 5 REBAR CONT. 3" ° ° SEE PLANS FOR SIZE & LOCATION EXISTING HOST POST TO CONCRETE CONNECTION DETAIL WALL W/ BRICK PAVERS SIDE VIEW SEE PLAN FOR COLUMN SIZE & SPACING (2) Z'X 2' X 1/8' ANGLE BRACKETS PRIMARYCONNECTORTOCONCRETE ATTACH TO BEAM W7d 412 SMS ITW SCOTS TAPCON 1/4' DIA 2' EMBED EACH SIDE OF COLUMN INTO CONCRETE (OR EQUAL) PRIMARY CONNECTOR TO CONCRETE 2'MIN —� ° ITW SCOTS TAPCON 1/4' DIA. Z' EMBED (OREQUAL) W MIN :'e..e::•e; 4' CONCRETE SLAB (TYP) # 5 REBAR CONT. 3" SEE PLANS FOR SIZE POST TO CONCRETE CONNECTION DETAIL SIDE VIEW 2-1/4" DIA X 3" LAG BOLTS THRU FASCIA INTO EACH TRUSS OR RAF (MIN 2"X 6° SYP) 24" MAX SPACING EXISTING TRUSSES OR RAFTERS — B" WIDE Z" GUTTER BRACE — @ EA. BEAM & 112 SPAN ATTACH TO FACIA W/ 2- 1/4" DIA. SS LAG SCREWS 2" MIN EMBEDMENT SUPER GUTTER 2"X 2" ATTACH TO TOP OF —I' �--2- EACH SIDE OF BEAM 318" DIA. SS GUTTER W/ #10 SMS @ 24° LAG BOLTS THRU ANGLE BRACKET, O.C. MAX & TO BEAM BEAM GUTTER, Z- BRACE & INTO FACIA 2" MIN. W 3 #10 SMS EMBEDMENT BEAM CONNECTION TO SUPER GUTTER PLAN VIEW 5" GUTTER ONLY 8 #12X 3/4" S.M.S. IN UPRIGHT 5 #12 X 3/4" IN ANGLE BRACE fi'SQU PARE PLAA TE . K- BRACE UPRIGHT POST UPRIGHT POST 5 #12X 3/4' IN ANGLE BRACE 6"X 8" SQUARE PLATE GIRT 8 #12 X 3/4" IN UPRIGHT PO; 6"X 8' SQUARE K- BRACE PLATE 8 #12X 3/4" IN ANGLE BRACE .'e: .'a, a .'e, .'e, .'e; .'e: ,'e; .•e; :'e; .'e .'e ::'e;'.•n;'�e:�' 1'', e, CONCRETE FLOOR 4 #12 X 314" IN BOTTOM PLATE AND UPRIGHT POST K- BRACING CONNECTION DETAIL N.TS. I� BRACES SHALL BE INSTALLED OUTSIDE FLUSH W/ EDGE OF STUDS 2- EA 3/8' DIA. SS LAG SCREWS FIELD VERIFY THAT FACIA IS SOLID W/NO SIGNS & 3/4" DIA. SS WASHERS THRU FACIA OF DETERIOATION PRIOR TO INSTALLATION INTO TRUSS TAIL 1-112' EMBEDMENT EVENLY SPACED GUTTER BRACE TO FASCIA USE 3/8" DIA. X 3' LAG BOLT 4 @ EACH GUTTER BRACE F8" LONG "Z' GUTTER BRACE &@# 10 ATTACX 3 S M. FROM 2"XI2' TO GUTTER S 24"MAXTRUSS —EXISTING FACIA OVERHANG FACIA TO TRUSS TAIL CONNECTION ANGLED OR STRAIGHT FIELD VERIFY THAT FACIA IS SOLID WINO SIGNS OF DETERIOATION PRIOR TO INSTALLATION #10 SMS j24" (TYPJI CORNER POST TO CORNER POST OR EVE RAIL CONNECTION N.rc PURLIN, BEAM OR (2) # 12 SMS THRU BRACE INTO RAIL OR BEAM 2"x T' x 0.93 ALUMINUM FLAT — PLATE ATTACH EACH END W/6#12SMS DIAG. RAIL OR "DIAGONAL ROOF BRACE DETAIL PLAN VIEW N.TA CONTINUOUS ANGLE SUPPORT FOR ANGLED FASCIA 24" MAX TRUSS OVERHANG BEAM 3/B" DIA LAG SCREW THRU GUTTER INTO FACIA MIN 1-112" EMBEDMENT INTO WOOD FACIA USE 3 # 14 S.M.S. AT EACH SIDE OF BEAM TO CHANNEL 2- # 12 S.M.S. THRU ANGLE BRACKET GUTTER., Z" BRACE JPER GUTTER BEAM CONNECTION TO SUPER GUTTER FASCIAANGLED OR STRAIGHT 5" GUTTER ONLY SEE PLAN FOR SIZE PURLINS ATTACHED TO BEAM AND SPA W13 #IOX 1-112' S.M.S. PURLINS ATTACHED TO BEAM W/ 3 #10X I AM S.M.S. PX 2' SNAP SECTIONS ATTACHED TO EVE RAIL Wl #12 X 2' S,M,S. 0 24' O.C. MAX SPACING (TYP) , ATTACH V X T TO POST W2 910 X 2' S.M.S. o 12 X 3/4' S.M.S. SCREWS FULL LAP TOP & BOTTOM @ 24' SPACING SQUARE BOTTOM MAX (TYP) 2-3/4" MIN LAP 5 # 12 SMS EACH SIDE STITCHING # 12 S.M.S. @ 24" O.C. (TYP) & 4" FROM EACH END MAX. 2"X 5" & LARGER POST OR COLUMN TO BEAM PURLIN MAY SLOPING OR HORTZONAL PARTIAL LAP CONNECTION MAY BE ROTATED FOR MANSARD OR GABLE APPLICATION (2)#1OX 4'THRU EVE RAIL '--- f r— NUMBER OF SCREWS SEE TABLE BELOW INTO PURLIN BOSSES SCREW PATTERN EQUAL SPACING 3/4 FROM END & SIDES & 518" MIN. BETWEEN EACH SCREW — BEAM SIZE (SEE PLAN) 7314" max 0 0 o ° 0 0 518' MIN. o ° o ° 3/4' max ° 0 0 . a 0 0 0 0 0 E A •I a 6' FOR m &' BEAMS & SMALLER & 10' FOR Z'XS'&2'X 10' BEAMS SIDE VIEW ATTACH 1' X 2' TO POST Wf2 #10 X 2' S.M.S. • ATTACH RELIVING CHANNEL W/ (4) 1'X A SNAP SECTIONS ATTACHED TO 2'X 2' #10 SMS EACH SIDE 'X S'X 1116' MIN. PLATE SIZE WI#1 OX 2' S,M,S. @ 18' O.C. SEE TABLE BELOW FOR MAX SPACING (TYP) SPLICE PLATE DETAILS SEE PLAN FOR COLUMN #12 SMS @ SIZE & SPACING 24" MAX SPACING SIDEWALL COLUMN TO PURLIN DETAIL I NTs 3/8" MAX. EDGE DISTANCE TOP & BOTIOM BEAM SIZE PLATE THICKNESS #14 SCREWS PER END # 14 SCREWS PER SIDE 2"X 4"X 0.045 X 0.100 SMB 1/4" 12 24 2"X 5"X 0.05OX 0.116 SMB 1/4" 12 24 2"X 6"X 0.050X 0.120 SMB 3/16" 14 28 2"X 7"X 0.050X 0.120 SMB 1/8" 14 1 28 2"X 8"X 0.072X 0.224 SMB 3/16" 16 32 2"X 9"X 0.072X 0.224 SMB 3/16" 16 32 2"X 9"X 0.082X 0.306 SMB 114" 20 40 2"X 10"X 0.092X 0.389 SMB 1/4" 24 48 ALL MITERED BEAM SPLICES SHALL BE MOMENT CONNECTIONS (4)#10X2' EACH SIDE 11 I I , I (TYP) `�� BEAMS LATERAL BRACING FOR BEA,-A�S�'� COLUMNS, PURLINS & CHAIr/y�F� COLUMN OR BEAM (TYP) " J FIELD VERIFY THAT FACIA IS SOLID WINO SIGNS OF DETERIOATION PRIOR TO INSTALLATION 4' WIDE Z GUTTER BRACE ATTACH TO FASCIA Wl2 1/4'X 3' LAG BOLTS & TO GUTTER W/ 2 # 12 SMS AT EACH PURUN TO GUTTER CONNECTION STING TRUSS I`___Fr—l'X2' FSUPER PURUNMAYSLOPING OR HORMONAL TX 2' X118' ANGLE ATTACH TO PURUN Wl4 #12 SMS EACH SIDE & TO GUTTER W/ 4 #12 SMS EACH SIDE 4-# 14 S.M.S. THRU ANGLE GUTTER BRACKET GUTTER. "Z" BRACE ITINUOUS ANGLE SUPPORT FOR ANGLED FASCIA PURLIN TO GUTTER DETAIL HOST STRUCTURE CONNECTOR TO CONCRETE USEITW SCOTS TAPCON 1/4" DIA: 2" EMBED(OR EQUAL) 1 "X 2" OB @ EACH END & 16" O.C. MAX. (TYP) CONNECTOR TO WOOD USE 1/4" DIA. LAG SCREWS INTO WOOD STUDS OR SOLID BACKING 2" MIN EMBED. (TYP) 1"X 2" TO RAIL INTERNALLY USE 4 # 10 X 2" SMS INT RAIL BOSSES 1 "X 2" OB MT& WOOD OR MASONRY HOST CHOOSE CONNECTOR THAT IS APPLICABLE 8" LONG "Z" GUTTER BRACE @ EA. BEAM GUTTER BRACE TO FASCIA ATTACH 2"X 2" TO BEAM USING 2 # 10 S.M.S. USE 3/8' DIA. X 3' LAG BOLT 2 & # 10 X 3" S.M.S. FROM 2"X 2" TO GUTTER @ EACH GUTTER BRACE I— @ 24" O.C. CONT. EXISTING TRUSS RISE WALL SIZE &HEIGHT SEE PLANS I ° 3/8- DIA LAG SCREW THRU"GUTTER• INTO FACIA MIN 1-1/2" EMBED.M IN INTO WOOD FACIA USE 3 # 14 S.M.S. AT EACJ IDE OF BEAM TO CHANNEL 2- # 12 S.M.S. THRU ANGLE BRACKET GUTTER. "Z" BRACE UPER GUTTER an I r/i'L=w- N.T.B 5" GUTTER ONLY o 43922 �<< * jrFUR WINDLOAD ANALYSIS ONLY OIF 1S�CHAEL E. ORISCOLL P.E. %r REG. 0431322 FOR ANGLED FASCIA —� 24" MAX TRUSS OVERHANG NECI \CEN,g�.� �Ll i of W c� J U� Q U� LL MW W W }. Z U W ' VJ W W o a _jloLLLL L Z Z LL LL Z 0 cn /D co M j U A I ✓�/ M co Ju N JJ Lo ze Ja Z ZF C ' J a JJ LAM O L11 LL In co U ZxJ J O O > w a A