HomeMy WebLinkAboutSUBMITTED PAPERSr
e � -� r---
1
DATE: FEES DUE: RECEIPT #: ' �� rermn
7 Planning & Development Services Department
' Building & Code Regulation Division
2300 Virginia Avenue
Ft. Pierce, FL 34982-5652
Tel. 772462-1553 C�0
APPLICATION FORT ROOF PERMIT PEE REVERSE SIDE FOR CO
1. NCJIONS
Location/Site Address: -I v L S "
2. Parcel ID Number:
3.
4.
Office Use
Only
Section
TownshipRan
a
a
Mn
Zonin
Land Use
Initials
Description of Project or Work Activity:1-t(2C-ri
Total Roof Area (square feet): .32�LL
6. Type of Roof: . [A Fiberglass Shingle . [ ] Concrete Roof Tile
7:
9.
] Wood Shake / Shingle
[ ]Tar &Gravel [� odified Bitumen [ ] Other
r all e§ Of Roofing Material (2 Sets) v ��
[V] Product Approval required.for typ g
[ ] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product
Approval attached
** Roof. Mitigation per F.S. 553.844 will be required.
Owner Information 8. Contractor Information V �, kQ .- FL Reg/Cert #: CCL 2&
Name: to 2 U l� � I J
Address: "1�LP �\b�� us Qd' County Cert #: �} II
City: j �f State: Business Name: /+E i Area P
Zip: Phone�lo��'� Cell Phone•
Value of Construction: $
**Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval.
CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be
done in c p ce with all ap . able laws regulating construction and zoning.
Ck jg=c� e,ck�ds
PRINT QUALnURS70WNERS NAME SIG£MTURE OF QUALIFIER/OWNE
STATE OF FLORIDA, COUNTY OF . L 0 -
ACKNOWLEDGED BEFORE ME7-To
I I DAY OF
31G
IS P�4ARA��
ALLY KNOWN ME OR S PRODUCE AS IDENTIFICATION
'C
�" °"�, JENNiFER OBERT
MY COMMISSION # DD837776
ATURE OF TYPE OR PRINT NAME OF NOTARY3inn I 11r - EXPIRES: Novanber 12, 2012
OF F7. Notary Dismount Assoc. Co.
1-800.3•NOTARY
COMMISSION NUMBER
NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY.RESULT IN YOUR PAYING TWICE
FOR u"ROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
Revised 4/26/2010
,:4111912011 15:10 (pp8)
P.001 l001
Public Works Department
Code Compliance Division
2300 Virginia Avenue
Ft. Pierce, FL 34982-5652
• INSPECTION AFFIDAVIT
RE: Permit # U 01- O 16A
,licensed as a(n) Contractor*/Engineer/Architect!
(Please print'name and circle license type) FS 468 Building Inspector*
* General, Building, Residential, or Roofing Contractor or any individual certifipd under 468 F.S. to make such an
inspection. All affidavits must include photographs of each plane of the roof with the permit # or address # clearly
shown marked on the deck for each inspection.
On or about _ (1 1 , I did personally inspect the roo
(Date & time)
'_deck nailinz and/or seconddry water barrier work at ,
(lob Site Address)
Based upon that exatniiiation I have determined the installation was done according to the
Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S.)
�4
C'
Signature & Seal License #
STATE OF FLORIDA
COUNTY OF • (�l lL�
Sworn to and subscribed before me this day of C\ \o C-fL-i . 204
by _� \ \ (i(l i(,� �. Who is personally known V or who has produced
as identification.
Notary Public, State of Florida I^ Q
Signature of Notary:
v
Commission No.: .
.. . _ cmI 9/27/07
' JENNII.-'ER OBERT
My COMMSS1014 a ODB37776
�£ EXalR1 5: Nova�er I2 2012
lor
-,fi
1-NO'rP" ARY F=NOn, A —CM
R EC J.,
JAN 19 2011
Pubs
St_ Lucil-L;'SIIrY: j 7
JOSEPH E. SMITH, CLERK OF THE CIRCUIT COURT - SAINT LUCIE COUNTY
FILE # 3549297 OR iC 3259 PAGE 1284, Recorded 01/10/20`% -,t 12:45 PM
NOTICE OF COMMENCEMENT
The undersigned hereby given notice that improvement will be made to certain real property, and in accordance with Chapter 713,
Florida Statues the following information is provided In the Notice of Commencement. �( ,�
I. DESCREMONOFPROPERTY (Legal description aF�Rpllnl)y
favailablejTAX FOLIO NUMBER: 1�/l/ ba-: ,
SUBDIVISION � L.TRACE LOT / HI. .N S
min 1-�)�i AI )
d. Nune and add" offw dmple ddebdder(if omhe thm Ouse)
ML,AD 4. CONTRACTOR'SNADRESS AND PHONE NUMBP3l: FA Area ROofllt &
7 _ terprooflngInc,
5. SURETYSNAME,ADDRESSANDPHONENUMBERANDBONDAMt Pierce, FL34982
6. LENDER'S NAME, ADDRESS AND PHONE NUMBER:
7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by
Section 713.13 (1) (a) 7., Florida Statutes:
NAME, ADDRESS AND PHONE HUMMER:
8. In addition to himself or herself, Owner designates the following toreceive a copy of the Lienor's Notice as provided in Section
713.13 (1) (b), Florida Statutes:
NAME, ADDRESS AND PHONE NUMBER:
9. Expiration date of notice of commencement (the expiration date is I year from the date of recording unless a different date is
specified): 20_
)r rr PT'fr nt Nsme and Pro We Signatory's TIUdOtflce
Officer/Director/Partner/Manager
State of Florida
County of! '
The foregoing instrument was acknowledged before me this day of &) A
By In "S)Ct as�� rL�3
(name of person) (type of authority,... e.g, officer, trustee, attorney in fact)
for 1/U M }S IF
(name of party on behalf of whom rostrum t u
MY COMMISSION a DDenn6
EXPIRPS:Nevr oba 12.201 Not signature sei
mJOM1S Aar RNam DawelA—
Under Penalties of perjury, I declare that I have read the foregoing and that the f .R1 ' ore true a best of my wledge and
belief (Section 92.525, Florida Statutes).
Rev.e6.1"I(S.Rec.&W roofNm Person Signi Above
STATE Of FtORI0A
$T.
TH1'
TRV
0 R I
By
Da__
000'
MM I�MAI)E
BUIMING CODE COMPLIANCE OFFICE (BCCO)
PRODUCT CONTROL DIVISION
MIAMI-DARE COUNTY, FLORIDA
METRO-DADE FLAGLER BUILDING
140 WEST FLAGLER STREET, SUITE 1603
MIAMI, FLORIDA 33130-1563
(305) 375-2901 FAX (305) 375-2908
NOTICE OF ACCEPTANCE (NOA)
GAF Materials Corp.
1361 Alps Rd.
Wayne, NJ 07470
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product
Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having
Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The BCCO (In Miami Dade County) and/or
the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for
quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer
will incur the expense of such testing and the AH1 may immediately revoke, modify, or suspend the use of such
product or material within their jurisdiction. BCCO reserves the right to revoke this acceptance, if it is
determined by BCCO that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the .Florida Building Code,
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF -Elk Timberline Prestique 30 Shingle
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by .the words Miami -Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall
be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection -at the job site at the request of the Building Off cial.
This revises NOA #07-0507.12 and consists of pages 1 through 5.
The submitted documentation was reviewed by Alex Tigera.
MIAMI•DADE COUNTY NOA No.:08-1110.07
Expiration D 200%,
Approval Date: 03/04/09
Page 1 of 5
ROOFING SYSTEM APPROVAL
Category:
Roofing
Sub -Category:
07310 Asphalt
Shingles
Materials
Dimensional
Deck Tyne:
Wood
1. SCOPE
This revises GAF -Elk Timberline Prestique 30 as manufactured by GAF Materials Corp described in
Section 2 of this Notice of Acceptance.
2. PRODUCT DESCRIPTION
Product Dimensions
Test
Product Description
Specifications
GAF -Elk Timberline 131/4"x.393/8-
TAS 110
Fiberglass reinforced heavy
weight asphalt
Prestique 30
roof shingle, with a laminate profile _
3. EVIDENCE SUBMITTED:
Test Agency
Test Identifier
Test Name/Report
Date
Underwriters Laboratories, Inc.
ASTM D3462
05CA47541
11/10/06
Underwriters Laboratories, Inc.
ASTM D3462
06CA31580
11/30/06
PRI Asphalt Technologies, Inc.
ASTM D3462
GAF-101-02-02
11/02/05
Underwriters Laboratories, Inc.
ASTM D3462
06NK05159
08/09/06
PRI Asphalt Technologies, Inc.
ASTM D3462
GAF-098-02-02
11/08/05
Underwriters Laboratories, Inca
ASTM D3462
02NK41809
08/11/02
Underwriters Laboratories, Inc.
ASTM D3462
03NK26444
16/17/03
Center for Applied Engineering
ASTM D3462
257989
05/13/97
Underwriters Laboratories, Inc.
TAS 107
OINK45803
04/13/94
Underwriters Laboratories,. Inc.
TAS 107
06NK05159
08/09/06
Underwriters Laboratories, Inc.
TAS 107
04NK04273
02/20/04
Underwriters Laboratories, Inc.
TAS 107
05CA42840
11/11/05
Underwriters Laboratories, Inc.
TAS 107
02NK41811
11/11/02
Underwriters Laboratories, Inc.
TAS 107
03CA35209
10/17/03
Underwriters Laboratories, Inc.
TAS 107
04CA13850
08/30/04
Center for Applied Engineering
TAS 100
257989
04/01/97
PRI Asphalt Technologies, Inc.
TAS 100
'GAF-044-02-01
01/13/04
PRI Asphalt Technologies, Inc.
TAS 100
GAF-101-02-01
11/09/05
PRI Asphalt Technologies, Inc.
TAS 100
GAF-116-02-02
03/23/06
PRI Asphalt Technologies, Inc.
TAS-100
ELK-083-02-01
10/16/02
ELK-084-02-01
10/15/02
ELK-085-02-01
10/14/02
ELK-086-02-01
10/24/02
ELK-087-02-01
10/21/02
ELK-088-02-01
10/16/02
ELK-107-02-01
10/09/03
ELK-108-02-01
10/09/03
ELK-109-02-01
10/09/03
MIAMI•DADECOUNTY NOA No.:08.1110.07
APPROVEDExpiration Date: 02/21/12
Approval Date: 03/04/09
Page 2 of 5
4. LIMITATIONS
4.1 Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials
Directory for fire ratings of this product.
4.2 Shall not be installed on roof mean heights in excess of 33 ft.
4.3 All products listed herein shall have a quality assurance audit in accordance with the Florida
Building Code and Rule 9B-72 of the Florida Administrative Code. .
5. INSTALLATION
5.1 Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
5.2 Flashing shall be in accordance with Roofing Application Standard RAS 115
5.3 The manufacturer shall provide clearly written application instructions.
5.4 Exposure and course layout shall be in compliance with Detail'A', attached.
5.5 Nailing shall be in compliance with Detail W, attached:
6. LABELING
6.1 Shingles shall be labeled withthe Miami -Dade Seal or the wording "Miami -Dade County
Product Control Approved".
MIAM MDE COUNTY
7. BUILDING PERMIT REQUIREMENTS
7.1 Application for building permit shall be accompanied by copies of the following:
7.1.1 This Notice of Acceptance.
7.1.2 Any other documents required by the Building Official or the applicable code in order
.to properly evaluate the installation of this system.
8. MANUFACTURING PLANTS
8.1
Tampa, FL
8.2
Michigan City, iN
8.3
Mobile, AL
8.4
Baltimore, MD
8.5
Myerstown, PA
8.6
Ennis, TX
8.7
Tuscaloosa, AL
8.8
Dallas, TX
MIAMI•DADE COUNTY NOA No.:08.1110.07
EXpiration Date: 02/21/12
Approval Date: 03/04/09
Page 3 of 5
DETAIL A
MLAMPnane COUNW7M NOA No.:08-1110.07
Expiration Date: 02/21/12
Approval Date: 03/04/09
Page 4 of 5
DETAIL B
1�
Front Side (Maximum Slope 12:1.2)
1:
Front Side (Maximum Slope 21:12)
Tab Sealant
2"
Back Side
END OF THIS ACCEPTANCE
MLAMMADE COUNTY
,...•
Release
Tape
I°
Release
Tape
I°
3/8H
NOA No.:08-1110.07
Expiration Date: 02/21/12
Approvals Date: 03/04/09
Page 5 of 5
FLa
ENGINEERING & TESTING, INC.
Phone: (866) 781-6889 • Fax: (866) 784-8550
www.iloridaengineeringandtesting.com
250 S.W. 131h Avenue
Pompano Beach, FL 33069
DATE: 01/10/11 JOB ORDER #: 11-268
CLIENT: All Area Roofing
ADDRESS: 3921 S. US Hi2hway 1 Fort Pierce, Florida 34982
PROJECT: Musick Residence Flat Wood Deck
ADDRESS: 7406 Hibiscus Road Fort Pierce, Florida
ASCE 7-05 DESIGN PRESSURE CALCULATIONS
Project Information:
Height = 15' Exposure: C Basic Windspeed: V=140 mph
Length = 23' Category: H Importance Factor: I=1.0
Width = 15' Slope: <7° KZ = 0.85, Kd = 0.85
Parapet Wall: < 3'
Design Calculations:
Velocity Pressure: q = 0.00256* [(0.85)(1.0)( 0.85)(140)2(1.0)] = 42.8 psf
Width of Pressure Coefficient: 0.l(15') = 1.5'
0.4(15') = 6.0' } use: 3'0"
Effective Wind Area: <1 Oftz
For parapet height three feet (3') or larger, zone three (3) can be treated as zone two (2)
(ASCE 7-05).
External Pressure Coefficient:
1)
GCP1 =
-1.0
2)
GCP2 =
-1.8
3)
GCP3 =
-2.8
Internal Pressure Coefficient:
1) GCPi = 0.18
Qualitly �1 A ��.%lssrcrd»ce
Page 2
01/10/11, Job Order # 11-268
All Area Roofing
Musick Residence - Flat Wood Deck
7406 Hibiscus Road; Fort Pierce, FL:
Design Pressures:
1) Field
P1 = 36.25*[(-1.0)
— (0.18)]
= -42.8 psf
2) Perimeter
P2 = 36.25*[(-1.8)
— (0.18)]
= -71.8 psf
3) Corners
P3 = 36.25*[(-2.8)
— (0.18)]
= -108.0 psf
Attachment Requirements:
FIL A
Based on N.O.A. #09-0224.01, pg 29 of 31, with a maximum design pressure of-45psf;
the following are our recommended fastening patterns to attach the proposed approved
base sheet to the wood deck utilizing approved 1-1/4" annular ring shank nails and 1-5/8"
tin caps:
Field: 9" o.c. @ laps and 2 staggered rows 12" o.c.
Perimeter: 9" o.c. @ laps and 3 staggered rows 9" o.c.
Corners: 9" o.c. @ laps and 5 staggered rows 9" o.c.
Notes: Corners and perimeter area dimension shall not be less than a = 3'0"
Contractor to verify that the fastening patterns meet manufacturer's
requirements for issuance of a warranty (as applicable).
All work shall be in compliance with the local building code product
control notice of acceptance and manufacturer specifications and Florida
Building Code 2007 Edition.
Wind load calculations based on ASCE 7-05 and information provided by
client.
All work shall be inspected by our field engineer (or authorized
representative) or a city inspector to verify compliance with specifications.
Sincerely,
Mark A. Mes ano; P.E:
Florida Engiheering &Testing, Inc.
Florida Reg. -No. ,48202 _ - --
Certificate of Authorization No. 6923
z
MIAMIDADE
BUILDING CODE COMPLIANCE OFFICE (BCCO)
PRODUCT CONTROL DIVISION
NOTICE OF ACCEPTANCE (NOA)
GAF Material Corporation
1361 Alps Road
Wayne, NJ 07470
MIAMI-DADE COUNTY, FLORIDA
METRO-DADE FLAGLER BUILDING
140 WEST FLAGLER STREET, SUITE 1603
MIAMI, FLORIDA 33130-1563
(305) 375-2901 FAX (305) 375-2908
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building
Code and Product Review Committee to be used in Miami Dade County and -other areas where allowed
by the Authority Having Jurisdiction (AHD.
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product
Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County)
reserve the right to have this product or material tested for quality assurance purposes. If this product or
material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing
and the AHJ. may immediately revoke, modify, or suspend the use of such product or material within
their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade
County Product Control Division that this product or material fails to meet the requirements of the
applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code and the High Velocity Hurricane Zone of the Florida.Building Code.
DESCRIPTION: GAF RUBEROEe Modified Bitumen Roof System for Wood Decks.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state
and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted
herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has
been no change in the applicable building code negatively affecting the performance of this product.
TFIt IINATION of this NOA will occur after the expiration date or if there has been a revision or
change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an
endorsement of any product, for sales, advertising or any other purposes shall automatically terminate
this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of
NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No. 07-1203.01 and consists of pages 1 through 31.
The submitted'documentation was reviewed by Jorge L. Acebo.
NOA No.: 09-0224.01
rtwourrn Expiration Date: 11/06/13
�►oEc
... , / Approval Date: 04/08/09
Page l of 31
ROOFING SYSTEM APPROVAL
Category
Roofing
Sub -Category:
Modified Bitumen
Material:
SBS/APP
Deck Type:
Wood
Maximum Design Pressure
-75 psf
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test
Product
Product
Dimensions
Specification
Description
Leak Bustefm MatrixTM
5, 55 gallons
ASTM D41
Asphalt concrete primer used to promote
307 Premium Asphalt
adhesion of asphalt in built-up roofing.
Primer
GAF Mineral Shield®
60 lb. Bags
ASTM D1863
Granules for surfacing of exposed asphalt,
Granules
1-00 lb. bags
cold process cement or emulsion. GAF
Mineral Shield® Granules shall be used
for flashing applications only.
Leak Bustefrm MatrixTM
5 gallons
ASTM D1227
Surface coating for smooth surfaced roofs.
305 Fibered Asphalt
Emulsion
Leak Bustefm MatrixTM 303
1, 5 gallons
ASTM D 2824
Fibered aluminum coating.
Premium Fibered Aluminum
Roof Coating
LeakBusterTM MatrixTM 322
55 gallons
Elastomeric roof coating.
Elastomeric Roof Coating
LeakBusterTM MatrixTM 306
55 gallons
Asphalt emulsion fibered.
LeakBusterTM MatrixTM 204
1,.5 gallons
ASTM D3019
Refined asphalt blended. with a mineral
ent
ASTM D3409
stabilizer and fibers. Permits adhesion to
ASTM D4586
wet and dry surfaces.
TGAFGLASO
ASTM D3409
#75
39.37" (1 meter)
ASTM D4601
Type II Asphalt impregnated and coated
Wide
glass mat base sheet.
GAFGLAS® #80
39.37" (1 meter)
ASTM D4601.
Type H Asphalt impregnated and coated,
ULTIMATM Base Sheet
Wide
fiberglass base sheet
GAFGLAS® Flex P1yTM 6
39.37".(1 meter)
ASTM D2178
Type Wasphalt impregnated glass felt
Wide
with asphalt coating.
GAFGLAS® Ply 4
39.37". (1 meter)
ASTM D2178
Type IV asphalt impregnated glass felt
Wide
with asphalt coating.
GAFGLAS®Mineral
39.37" (1 meter)
ASTM D3909
Asphalt coated, glass fiber mat cap sheet
Surfaced Cap Sheet
Wide
surfaced with mineral granules.
NOA No.: 09-0224.01
MWM ® UNTYM Expiration Date: 11106113
Approval Date: 04/08/09
Page 2 of 31
Test
Product
Product
Dimensions
Specification
Description
GAFGLAS®EnergyCalYm
39.37" (1 meter)
ASTM D3909
Asphalt coated, glass fiber mat cap sheet
Mineral Surfaced Cap Sheet
Wide
surfaced with mineral granules with
factory applied layer of TOPCOAT®
EnergyCoteTM.
GAFGLAS® EnergyCapTM
39.37" (1 meter)
ASTM D3909
Asphalt coated, glass fiber mat cap sheet
BUR Mineral Surface Cap
wide
EnergystarTM
surfaced with mineral granules with
Sheet
Title 24
factory applied EnergyCotdrM
Compliant
GAFGLAS®
39.37" (1 meter)
ASTM D3672
Fiberglass base sheet coated on both sides
STRATAVENT*
Wide
ASTM D4897
with asphalt. Surfaced on the bottom side
EliminatorTM Perforated
with mineral granules embedded in
asphaltic coating with factory
perforations.
GAFGLAS® Flashing
various
Asphalt coated glass fiber mat flashing
sheet available in three sizes.
GAFGLAS®
39.37" (1 meter)
ASTM D3672
Fiberglass base sheet coated on both sides
STRATAVENT"
Wide
ASTM D4-897
with asphalt. Surfaced on the bottom side
Eliminatofm Perforated'
with mineral granules embedded in
Nailable
asphaltic coating.
RUBEROe SBS
1 meter (39.3T')
ASTM D6164
Non -Woven Polyester mat coated with
Heat-We1dTM Smooth
wide
polymer -modified asphalt and smooth
surfaced.
RUBEROID® SBS
1 meter (39.37")
ASTM D6164
Non -Woven Polyester mat coated with
Heat-WeldTM Granule
wide
polymer modified asphalt and surfaced
with mineral granules.
Roof MatchTM
107 sq. ft.
ASTM D6222
Non -woven polyester mat coated with
SBS Mop Granule
(9.9 m2)
ASTM D5147
polymer modified asphalt and surfaced
with colored mineral granules.
RU13EROO SBS
1 meter (39.37")
ASTM D6164
Non -Woven Polyester mat coated with
Heat=WeldTM 170 FR
wide
fire retardant polymer modified asphalt
and surfaced with mineral granules.
RU13EROO SBS
1 meter (39.37")
ASTM D6164
Non -Woven Polyester mat coated with
Heat-WeldTM PLUS
wide
polymer modified asphalt and surfaced
with mineral granules.
RUBEROMP SBS
1 meter (39.37'�
ASTM D6164
Non -Woven Polyester mat coated with
Heat-WeldTm PLUS FR
wide
fire retardant polymer modified asphalt
and surfaced with mineral granules.
RUBEROID®EnergyCap
1 meter (39.37")
ASTM D6164
A fiberglass mat reinforced, SBS modified
SBS Heat-WeldTM PLUS FR
wide
bitumen cap membrane.
RUBEROID® Modified 39.37" (1 meter) ASTM D4601, Premium glass fiber reinforced SBS-
Base Sheet Wide Type Ii, UL Type modified base sheet
G2 BUR
RUBEROO SBS 1 meter (39.37") ASTM D6164 Non -Woven Polyester mat coated with
Heat WeldTM 25 wide polymer -modified asphalt and smooth
surfaced.
NOA No.: 09-0224.01
MAW DADE COUNTY
Expiration Date: 11/06/13
• • Approval Date: 04/09/09
Page 3 of 31
Test
Product
Product
Dimensions
Specification Description
RUBEROID® Mop Granule 39.37" (1 meter)
ASTM D6222 Non -woven polyester mat coated with
Wide
ASTM D5147 polymer modified asphalt and surfaced
RUBEROID® MOP Smooth 1 sq. roll
with mineral granules.
ASTM D6298 Non -woven polyester mat coated with
87 lbs.
ASTM D5I47 polymer -modified asphalt and smooth
RUBEROID® MOP PLUS
39.37" (1 meter)
surfaced.
ASTM D6164 Non -woven polyester mat coated with
Wide
ASTM D5147 polymer modified asphalt and surfaced
RUBEROID® MOP 170FR
39.37" (1 meter)
ASTM D6164
with mineral granules.
Non -Woven polyester mat coated with fire
Wide
ASTM D5147
retardant polymer modified asphalt and
RUBEROID® MOP FR
39.37" (1 meter)
ASTM D6164
surfaced with mineral granules.
Non -Woven polyester mat coated with fire
Wide
ASTM D5147
retardant polymer modified asphalt and
RUBEROV TORCH
39.37' (1 meter)
ASTM D6222
surfaced with mineral granules.
Heavy duty, polyester reinforced, asphalt
Smooth
'Wide
ASTM D5147
modified bitumen membrane, smooth
'
UBEROID® TORCH
39.37" (1 meter)
ASTM D6222
surface.
Heavy duty, polyester reinforced, asphalt
r Granule
Wide
ASTM D5147
modified bitumen membrane; granule
RUBEROID®EnergyCap
1 meter (39.37")
ASTM D6222
surface.
A fiberglass mat reinforced, SBS modified
Torch Granule FR
wide
ASTM D5147
bitumen cap membrane.
Roof MatchTm
107 sq. ft.
ASTM D6222
Non -woven polyester mat coated with
APP Torch Granule
(9.9 m2)
ASTM D5147
polymer modified asphalt and surfaced
with colored mineral granules.
RUBEROID® TORCH
39.37" (1 meter)
ASTM D6222
Heavy duty, polyester reinforced, asphalt
PLUS
Wide
ASTM D5147
modified bitumen membrane, granule
RUBEROiD® TORCH FR
39.37" (1 meter)
ASTM D6222
surface .
Heavy duty, polyester reinforced, coated
Wide
ASTM D5147
with fire retardant asphalt modif ed
RUBEROID® 170FR
39.37" (1 meter)
ASTM D6222
bitumen membrane, granule surface.
Heavy duty, polyester reinforced, coated
TORCH
Wide
ASTM D5147
with fire retardant asphalt modified
bitumen membrane, granule surface.
RUBEROID® EnergyCap
1 meter (39.37') .
ASTM D6163
A fiberglass mat reinforced, SBS modified
SBS Heat Weld Plus FR
wide
ASTM D5147
bitumen cap membrane.
RUBEROV 20
39.37" (1 meter)
ASTM D6163
SBS modified asphalt base sheet reinforce
RUBEROID®30
Wide
ASTM D5147
with a glass fiber mat.
39.37" (1 meter)
ASTM D6163
Non woven fiberglass mat coated with
Wide
ASTM D5147
polymer modified asphalt and surfaced
with mineral granules.
NOA No.: 09-0224.01
MuuhapapECOUNi Expiration Date: 11/06/13
Approval Date: 04/08/09
Page 4 of 31
` 1 '
Product
RUBEROID®30 FR
Dimensions
Test Product
Specification Description
39.37" (1 meter)
ASTM D6298 Non woven fiberglass mat coated with fire
Wide
ASTM D5147 retardant, polymer modified asphalt and
RUBEROID®EnergyCap
1 meter (39.37")
surfaced with eral granules.
ASTM D6163 A fiberglass atlre' forced, SBS modified
SBS 30 FR
wide
bitumen cap membrane.
RUBEROID®
ULTRACLAD® SBS
39.37" (1 meter_)
ASTM D6163 Woven fiberglass mat coated with
Wide
ASTM D5147 Polymer modified asphalt surfaced with
RUBEROID®.Dual FR
39.37" (1 meter)
copper or
ASTM D6164 Non woovaen polyester and berss sgglass
Wide
mat
ASTM D5147 coated with file retardantpolymer-
modified asphalt and surfaced with
Vent Stacks
(metal and plastic)
mineral granules.
TAS 100(A) One-way valve vent used to relieve built
ASTM D1929 up pressure within the roof system. GAF
ASTM D635 Vent Stacks are available in metal or
GAF Built -Up Roofing
Asphalt
100 lb. cartons,
plastic.
ASTM D312, Interply mopping and surfacing asphalt
bulk
Types I, II, III
RUBEROID® MOD Asphalt
Asphalt L & Asphalt P
60 lb. kegs
and IV
SEBS modified asphalt
TOPCOAT'
Surface Seal SB
5 gallons
Surface coating for smooth surfaced and
mineral surfaced roofs.
LEAK BUSTERTM
MatrixTM 715 *MB
5 .gallons
ASTM D3412 Surface coating for smooth surfaced and
ASTM
Elastomeric Roofing
D21 mineral surfaced roofs.
ASTM D 1475
Membrane
ASTM E 1644
EnergyCoteTM Coating
2, 5 gallons
ASTM D6083
Highly reflective elastomeric coating
VersaShield®
350 sq.* ft roll
ASTM-D226 Non -Asphaltic Fiberglass -Based
TOPCOAT' FireShield ®
4869 Type I, II Underlayment
5, 55 gallons ASTM D412 Elastomeric roofing membrane
MB
ASTM D21
ASTM 1475
Leak BusterTM MatrixTM
ASTM E1644
5 gallons Surface coating for smooth surfaced
531 WeatherCoteTM
Elastomeric Flashing Grade
and
mineral surfaced roofs.
LeakBusterTM MatrixTM 201
Premium SBS Flashing
5 gallons ASTM D3019 Cold Applied Modified SEBS Asphalt
Adhesive —Flashing Grade.
Leak BusterTM MatrixTM
102 SBS Adhesive Label
5 gallons ASTM D3019 Cold Applied Modified SEBS Asphalt
Adhesive.
NOA No.: 09-0224.01
Mu�r+Nn�anEcourrnr Expiration Date: 11/06/13
PRMD Approval Date: 04/08/09
Page 5 of 31
Test
Product
Product
Dimensions
Specification
Description
Leak BusterTM MatrixTm 202
5 gallons
ASTM D4586
Cold Applied Modified SEBS Asphalt
SBS Flashing Cement Label
Adhesive — Flashing Grade.
Leak BusterTM MatrixTM
5 .gallons
ASTM D4586
Standard Plastic Asphalt Roofing Cement
203 Plastic Roof Cement
Label
Leak BusterTM MatrixTM
5 gallons
ASTM D3019
Cold Applied Asphalt Adhesive.
103 Cold Process Adhesive
Label
LeakBusteim Matrkm 304
5 gallons
ASTM D2824,
Non-Fbered. Aluminum pigmented,
Non-Fibered Aluminum
Type I
asphalt roof coating.
Roof
Leak BusterTM MatrixTM
5 gallons
ASTM D412
Surface coating for smooth surfaced and
602 MB Xtra Elastomeric
ASTM B 117
mineral surfaced roofs.
Roofing Membrane
ASTM C794
ASTM G21
FTMS141.6271
ASTM D2196
ASTM D1475
ASTM E 1644
TOPCOAT® MB Plus
5, 55 gallons
ASTM D412,
Water -based, low VOC, sprayable
ASTM D21,
polymeric Iiquid, which cures to form a
ASTM D1475
seamless rubber membrane:
ASTM E1644
NOA No.: 09-0224.01
MIAMFDADECOUNTY Expiration Date: 11/06/13
Approval Date: 04/08/09
Page 6 of 31
t �f
APPROVED INSULATIONS:
Table 2
Product Name
Product Description
Manufacturer
(With Current NOA)
EnergyGuardTm Fiberboard
Fiberboard insulation
GAF Materials Corp.
EnergyGuardTM Permalite
Perlite insulation board
GAF Materials Corp.
EnergyGuardTM Strip
Cut perlite board
GAF Materials Corp.
EnergyGuardTM Recover Board
Perlite recover board
GAF Materials Corp.
EnergyGuardTM Tapered Edge Strip
Tapered perlite board
GAF Materials Corp.
EnergyGuardTM Polylso
Polyisocyanurate foam insulation
GAF Materials Corp.
EnergyGuardTM RA, RN
Polyisocyanurate foam insulation
GAF Materials Corp.
EnergyGuardTM Composite, RA
Polyisocyanurate/wood fiberboard or
GAF Materials Corp.
perlite composite
DensDecO
Water resistant gypsum board
G P Gypsum Corp.
DensDeck Prime'
Water resistant gypsum board
G-P Gypsum Corp.
DensDeck DuraGuardTM
Water resistant gypsum board
G-P Gypsum Corp
StructodeV
Wood fiber insulation board
Knight Celotex
StructodeV TD
Flame Resistant High Density Wood
Knight-Celotex
Fiber board.
SecurockTM
Fiber reinforced roof board
USG Corporation
APPROVED FASTENERS:
TABLE 3
Fastener Product
Product
Manufacturer
Number Name
Description Dimensions
(With Current NOA)
1, Drill-TecTM #12 Standard,,
Insulation fastener and Various
GAF Materials Corp.
#14 and #15 extra Heavy
Base Play fastener for
Duty Fastener, Heavy Duty steel, wood & concrete
Roofing Fastener .
'decks.
2. Drill-TecTM ASAP ,
Pre -assembled Drill-TecTM Various
GAF Materials Corp.
Fasteners and metal and
.plastic plates.
3. Drill-TecTM CR Base
Base sheet fastening Various
GAF Materials Corp.
Sheet Fastener and Plate
assembly.
4. Drill-Tedm Galvalume
Round Galvalume stress 3" and 3 %z'
GAF Materials Corp.
Plates
plates.
5. Drill-TecTM Polypropylene
Round polypropylene 3" and 3 %Z'
GAF Materials Corp.
Plates
stress plates.
6. Drill-Te6m AccuTrac
Square Galvalume® coated 3" Square
OMG
Plate
steel plate.
NOA No.: 09-0224.01
Expiration Date: 11/06/13
MIAMFDADE CODU
...
Approval Date: 04/08/09
Page 7 of 31
EVIDENCE SUBMITTED:
Test Agency
Test Identifier
Description
Date
Factory Mutual Research Corp.
3029832
4470 - TAS 114
05/11/07
3010215
4470 - TAS 114
03/O1/01
3001276
4470 - TAS 114
.01/28/99
1B9A8.AM
4470 - TAS 114
09/04/97
3D4Q2.AM
4470 - TAS 114
04/30/97
ODIA8.AM
4470 - TAS 114
04/01/98
Underwriters Laboratories
TGFU.RI9254
UL 790
10/27/06
Trinity Engineering
4483.04 97-1
TAS 114
06/06/97
PRI Asphalt Technologies, Inc.
GAF-020-02-01
ASTM D 249
02/01/02
ASTM D 4977
IRT-ARCON Inc.
02-005
TAS 114
03/01/02
02-014
TAS 114
04/08/02
Trinity I ERD
01-039
TAS 114
03/01/02
G6850.08.08
ASTM D6164
08/29/08
G6850.08.08
ASTM D6163
08/01/08
G6850.10.08
ASTM D6222
10/06/08
G6850.11.08
ASTM D6222
11/05/08
NOA No.: 09-0224.01
MIAMI-DAD COExpiration Date: 11/06/13
' ' ' • • UNTY Approval Date: 04/08/09
Page 8 of 31
APPROVED ASSEMBLIES
Membrane Type:
SBS
Deck Type 1I:
Wood, Insulated
Deck Description:
19/32" or greater plywood or wood plank
System Type A(1):
Anchor sheet mechanically fastened, all layers of insulation adhered with
approved asphalt.
All General and System Limitations shall apply.
One or more layers of any of the following insulations.
Insulation Layer
Insulation Fasteners
('fable 3)
EnergyGuaru-- Polylso, RA, RNy EnergyGuardTM Composite RA,
Minimum 1" thick
N/A
Wood Fiber, Structodek®, StructodeV TD, EnergyGuardTM Recover Board
Minimum %" thick N/A
EnergyGuardTM Perlite
Minimum %" thick
N/A
Fastener
Density/fe
N/A
N/A
N/A'
Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt
within the EVT range and at a rate of 2040 lbs/100 fe. Please refer to Roofing Application
Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used
only as base layers with a second layer of approved top layer insulation installed as the final
membrane substrate. Composite insulation panels may be used as a top layer placed with the
polyisocyanurate side facing down. GAF requires either a ply of GAFGLAS® STRATAVENT®
EliminatorTM Perforated laid dry or a layer of EnergyGuardTM, Perlite or wood fiber overlay -
board on all polyisocyanurate applications.
Fire Barrier: FireOutTM Fire Barrier Coating, VersaShield®Non-Asphaltic Fiberglass -Based
(optional) . Underlayment or SecurockTM.
Anchor sheet: GAFGLAS® #80 ULTIMATM Base Sheet, STRATAVENT® BliminatorTm Nailable
Base Sheet, RUBEROID® Modified Base Sheet, RUBEROID® 20, RUBEROID®
SBS Heat-WeldTM Smooth or RUBEROID® SBS Heat-WeldTM 25 base sheet
mechanically fastened to deck as described below;
Fastening GAFGLAe Ply 4, GAFGLAS® Flex PlyTM 6, GAFGLAS® #75 Base Sheet or any
Options: of above Anchor sheets attached to deck with approved annular ring shank nails
and tin caps at. a fastener spacing of 9" o.c. at the lap staggered and in two rows
12" o.c. in the field.
(Maximum Design Pressure -45 psf, See General Limitation #7)
GAFGLAS® Ply 4, GAFGLAS® Flex P1yTM 6, GAFGLAS® #75 Base Sheet or any
of above Anchor sheets attached to deck with Drill-TecTM #12 standard, #14 or #
15 Screws and 3" Drill-TecTM steel plate or Drill-Tedm AccuTrac PIates, 12" o.c.
in 3 rows. One row is in the 2" side lap. The other rows are equally spaced
approximately 12" o.c. in the field of the sheet.
(Maximum Design Pressure -45 psf, See General Limitation #7
NOA No.: 09-0224.01
Mwr�waoEcounrnr Expiration Date: 11/06/13
APPROVED Approval Date: 04/08/09
Page 9 of 31
I
GAFGLAS® Flex PlyTM 6, GAFGLAS® #75 Base Sheet or any of above Anchor
sheets attached to deck with approved annular ring shank nails and tin caps at a
fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the
field.
(Maximum Design Pressure —52.S psf, See General Limitation #7)
GAFGLAS® #80 ULTIMATM, RUBEROID®20, RUBEROID® Mop Smooth, base
sheet attached to deck with approved annular ring shank nails and tin caps at a
fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the
field.
(Maximum Design Pressure —60 psf, See General Limitation #7)
GAFGLAS® #75 Base Sheet or any of above Anchor sheets attached to deck with
Drill-Tedm #12 standard, #14 or # 15 Screws and 3" Drill-TecTM steel plate or
Drill-TecTM AccuTrac Plates, 12" o.c. in 4 rows. One row is in the 2" side lap.
The other rows are equally spaced approximately 9" o.c. in the field of the sheet.
(Maximum Design Pressure —60 psf, See General Limitation #7) .
Any of above Anchor sheets attached to deck approved annular ring shank nails
and 3" inverted.Drill-TecTM insulation plates at a fastener spacing of 9" o.c. at the
4" lap staggered 'in two rows 9" in the field..
(Maximum Design Pressure —60 psf, See General Limitation #7)
GAFGLAS® #75 Base Sheet or any of above Anchor sheets attached to deck with
Drill-TecTM #12 standard, #14 or # 15 Screws and 3" Drill-TecTM steel plate or
Drill-TecTM AccuTrac Plates, 8" o.c. in 4 rows. One row is in the 2" side lap. The
other rows are equally spaced approximately 9" o.c. in the field of the sheet.
(Maximum Design Pressure —75 psf, See General Limitation #7)
Base Sheet: (Optional) Install one ply of GAFGLAS® #75, GAFGLAS® #80 ULTIMATM Base
Sheet, GAFGLAS® PLY 4, GAFGLAS Flex PlyTM 6, GAFGLAS®
STRATAVEN170 Eliminatoim Perforated (laid dry), RUBEROID® Modified Base
Sheet, RUBEROID® MOP Smooth, RUBEROID® 20, RUBEROID® SBS Heat-
WeldTM'Smooth or RUBEROID® SBS Heat-WeldTM 25 directly over the top layer
of insulation. Adhere with any approved mopping asphalt applied within the EVT
range and at.a rate of 20-40 '1bsJsq (see General Limitation #4).
Ply Sheet: (Optional) One or more plies GAFGLAS® PLY 4, GAFGLAS® Flex PlyTM 6
sheet, GAFGLAS® #80, RUBEROID® MOP Smooth, RUBEROIDD 20 adhered in
a full mopping of approved asphalt applied within the EVT range and at a rate of
20-40 lbsJsq.
Membranes One or more plies of RUBEROID®2% RUBEROID® 30, RUBEROV
EnergyCap SBS 30 FR, RUBEROID0 30 FR RUBEROID® MOP Smooth,
RUBEROID®Mop 170 FR, RUBEROID®Mop Granule, RoofMatchTM SBS Mop
Granule, RUBEROID® MOP PLUS, RUBEROID® MOP FR, RUBEROID®
ULTRACLAD0 SBS, or RUBEROID® Dual FR fully adhered in an approved
asphalt at an application rate of 25 lb./sq. f 15%.
NOA No.: 09-0224.01
Expiration Date: 11/06/13
Approval Date: 04/08/09
Page 10 of 31
Surfacing: (Optional, required if RUBEROID® MOP Smooth or RUBEROID® 20 is top
membrane) Install one of the following:
1. Gravel or slag applied at 400 lbs./sq. and 3001bs./sq. respectively in a flood
coat of approved asphalt at 60 lbs./sq. or applied in a flood coat of Leak
BusterTM MatrixTM 103 Cold Process Adhesive applied at a rate of 3 gallsq.
2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral
Surfaced Capsheet adhered in a full mopping of approved asphalt applied
within the EVT range and at a rated 20-401bs./sq.
3. Leak Busteim MatrixTM 303 Premium Fibered Aluminum Roof Coating, at
1.5 gal,/sq.
4. Leak BusterTM MatrixTM 715, Leak Busteim MatrixTM 322, TOPCOAT'
MB+, TOPCOAT® Firbshield Elastomeric Roofing Membrane, applied at l to
1.5 gal./sq.
5. Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane,
EnergyCotea roof coating applied at 1 to 1.5 gal./sq.
6. TOPCOAT®. Surface Seal, TOPCOAT' Fireshield® SB Solvent based
Elastomeric Roofing Membrane applied at Ito 1.5. gal./sq
7. Advance Green Technologies Photovoltaic Laminate solar energy collector
auxiliary roof equipment installed in compliance with manufacturer's
specifications and applicable Building Codes.
Maximum
Design Pressure: See Fastening Above
NOA No.: 09-0224.01
Expiration Date: 11/06/13
Approval Date: 04/08/09
Page 11 of 31
{
Membrane Type: APP/SBS Heat Weld
Deck Type II: Wood, Insulated
Deck Description: 19/32" or greater plywood or wood plank
System Type A(2): Anchor sheet mechanically fastened, all layers of insulation adhered with
approved asphalt.
All General and System Limitations shall apply.
One or more layers of any of the following insulations.
Insulation Layer Insulation Fasteners
Fastener
(Table 3)
Density/fe
EnergyGuardTM RA, EnergyGuardTM RA Composite
Minimum I" thick N/A
N/A
Wood Fiber, StructodeV, StructodeV TD, EnergyGuardTM RecoverBoard
Minimum %" thick N/A
N/A
EnergyGuardrm Perfite
Minimum %" thick N/A'
N/A
Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt
within the EVT range and at a rate of 2040 lbs/100 fe. Please refer to Roofing Application
Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only
as base layers with a second layer of approved top layer insulation installed as the final membrane
substrate. Composite insulation panels may be used as a top layer placed with the
polyisocyanurate side facing down. GAF requires either a ply of GAFGLAS® STRATAVENT®
EliminatorTM perforated laid dry or a layer of EnergyGuardTM Perlite or EnergyGuardTM wood
fiber overlay board on all polyisocyanurate applications.
Fire Barrier: FireOutTM Fire Barrier Coating, VersaShieie Non -Asphaltic Fiberglass -Based
(optional) Underlayment or SecurockTM.
-Anchor sheet: GAFGLAS®#80 ULTIMA TM Base Sheet, STRATAVEN14 EliminatorTM
Nailable, RUBEROID® Modified Base Sheet, RUBEROID®'20, RUBEROV
SBS Heat WeldTM Smooth or RUBEROV SBS Heat=WeldTM 25 base sheet
mechanically fastened to deck as described below;
Fastening GAFGLAS® Ply 4, GAFGLAS® Flex P1yTM 6, GAFGLAS® #75 Base Sheet or any
Options: of above Anchor sheets attached to deck with approved annular ring shank nails
and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows
12" o.c. in the field.
(Maximum Design Pressure --4S psf, See General Limitation #)
GAFGLAS® Ply 4, GAFGLAS® Flex P1yTM 6, GAFGLAS® #75 Base Sheet or any
of above Anchor sheets attached•to deck with Drill-TecTM #12 standard, #14 or #
15 Screws and 3" .Drill-TecTM steel plate or Drill-TecTM AccuTrac Plates, 12" o.c.
in 3 rows. One row is in the 2" side lap. The other rows are equally spaced
approximately 12" o.c. in the field of the sheet.
(Maximum Design Pressure -4S psf, See General Limitation #7)
NOA No.: 09-0224.01
MAMI•DADE COUNTY Expiration Date: 11/06/13
Approval Date: 04/08/09
Page 12 of 31
i
GAFGLAS® Flex P1yTM 6, GAFGLAS® #75 Base Sheet or any of above Anchor
sheets attached to deck with approved annular ring shank nails and tin caps at a
fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the
field.
(Maximum Design Pressure 52.5 psf, See General Limitation #7)
GAFGLAS® #80.ULTIMATM, RUBEROID® 20, RUBEROID® Mop Smooth, base
sheet attached to deck with approved annular ring shank nails and tin caps at a
fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the
field.
(Maximum Design Pressure —60 psf, See General Limitation #7)
GAFGLAS® #75 Base Sheet or any of above Anchor sheets attached to deck with
Drill-Tedm #12 standard, 914 or # 15 Screws and 3" Drill-TecTM steel plate or
Drill-TecTM AccuTrac Plates, ] 2" o.c. in 4 rows. One row is in the 2" side lap.
The other rows are equally spaced approximately 9" o.c. in the field of the sheet.
(Maximum Design Pressure —60 psf, See General Limitation #7)
Any of above Anchor sheets attached to deck approved annular ring shank nails
and 3" inverted Dril]-Tedm insulation plates at a fastener spacing of 9" o.c. at the
4" lap staggered in two rows 9" in the field.
(Maximum Design Pressure —60 psf, See General Limitation. #7)
GAFGLAS®#75 Base Sheet or any of above Anchor sheets.attached to deck with
Drill-TeOm #12 standard, #14 or # 15 Screws and 3" Drill-Tedm steel plate or
Drill=TecTM AccuTrac Plates, 8" o.c. in 4 rows. One row is in the 2" side lap. The
other rows are equally spaced approximately 9" o.c. in the field of the sheet.
(Maximum Design Pressure —75 psf, See General Limitation #7)
Base Sheet: Install one.ply of GAFGLAS® #75, GAFGLAS® #80 ULTIMATM Base Sheet,
GAFGLAS®. PLY 4, GAFGLAS® Flex PlyTM 6, GAFGLAS® STRATAVENT®
Eliminatoim Perforated (laid dry), RUBEROID® Modified Base Sheet,
RUBEROV MOP Smooth, RUBEROID® 20, RUBEROV SBS Heat-WeldTH
Smooth or RUBEROV. SBS Heat-Weldrm 25 directly over the top layer of
insulation. Adhere with any approved mopping asphalt applied within the EVT
range and at a rate of 20-40 lbs./sq (see General. Limitation #4).
Ply Sheet: (Optional except over RUBEROID® Modified Base Sheet, RUBEROID® MOP
Smooth, RUBEROID® 20, RUBEROID® SBS Heat We]dTM Smooth or
RUBEROID® SBS Heat-Weldrm) One or more plies GAFGLAS® PLY 4,
GAFGLAS® Flex P1yTM 6 or GAFGLAS® #80 ULTIMATM sheet adhered in a full
mopping of approved asphalt applied within the EVT range and at a rate of.20-40
lbs./sq. or RUBEROID® Torch Smooth torch applied according to manufacturer's
application instructions.
NOA No.: 09-0224.01
Expiration Date: 11/06/13
Approval Date: 04/08/09
Page 13 of 31
Membrane:
One ply of RUBEROID® Torch Smooth, RUBEROID® Torch Granule,
RUBEROID®EnergyCap Torch Granule FR, Roof MatchTM APP Torch Granule,
RUBEROID® Torch Plus Granule, RUBEROV EnergyCap Torch Plus FR,
or RUBEROW9 Torch FR torch applied according to manufacturer's application
instructions.
Or
One or more plies of RUBEROID® SBS Heat WeldTM PLUS, RUBEROID® SBS
Heat WeldTM PLUS FR, RUBEROID® SBS Heat-WeldTM 170 FR, RUBEROID®
EnergyCapTM SBS Heat Weld Plus, RUBEROID®SBS Heat WeldTM,
RUBEROID® SBS Heat WeldTM Smooth, RUBEROMOULTRACLAD® SBS and
RUBEROV SBS Heat-WeldTM 25 applied according to manufacturer's
application instructions.
Surfaeing:
(Optional, required if RUBEROV MOP Smooth or RUBEROW0 20 is top
membrane) Install one of the following:
l . Gravel or slag applied at 400 lbs./sq. and 300 lbsJsq. respectively in a flood
coat of approved asphalt at 60 lbsJsq. or applied in a flood coat of Leak
Busteim MatrixTM -103 Cold Process Adhesive applied at a rate of 3 gal./sq.
2. GAFGLAS® Mineral Surfaced Cap Sheet; GAFGLAS® Energy Cap Mineral
Surfaced Capsheet adhered in a full mopping of approved asphalt applied
within the EVT range'and at a rate of20-40 IbsJsq.
3. Leak Buster' MatrixTM 303 Premium Fibered Aluminum Roof Coating;, at
1.5 gaIJsq..
4. Leak BusterTM MatrixTm 715, Leak BusterTM MatrixTM 322, TOPCOAT®
MB+, TOPCOAT® Fireshield Elastomeric Roofing Membrane, applied at 1 to
1.5 gal./sq.
5. Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane,
EnergyCoteo roof coating applied at 1 to 1.5 galJsq.
6. TOPCOATS' Surface Seal, TOPCOAT® Fireshieldo SB Solvent based
Elastomeric Roofing Membrane applied at Ito 1.5 gal./sq
7. Advance Green Technologies Photovoltaic Laminate solar energy collector
auxiliary roof equipment installed in compliance with manufacturer's
specifications and applicable Building Codes.
Maximum
Design Pressure:
See Fastening Above
NOA No.: 09-0224.01
MMWADECOUNTYM Expiration Date: 11/06/13
" Approval Date: 04/08/09
Page 14 of 31
Membrane Type: SBS
Deck Type II: Wood, Insulated
Deck Description: 19/32" or greater plywood or wood plank
System Type B(1): Optional, base sheet Iaid dry; base layer of insulation mechanically fastened,
optional top layer adhered with approved asphalt.
All General and System Limitations shall apply.
One or more layers of any of the following insulations.
Base Insulation Layer
Insulation Fasteners
Fastener
EnergyGuardTM RA
(Table 3)
Density/ft
Minimum 1.3' thick
1, 2, or 3
1:3 ft2
EnergyGuardTM RN
Minimum 1.4" thick
1, 2, or 3
1:3 ft2
EnergyGuardTM
Minimum 1.3" thick
1, 2, or 3
1:3 ft2
EnergyGgardTM
Minimum 1.5" thick
3
1:3 ft2
EnergyGuardTM Perlite
Minimum %" thick
1, or 3
1:2 ft2
Wood Fiber, EnergyGuardTM Fiberboard, StructodeV, StructodeV TD
Minimum I" thick
1, 2, or 3
1:2 ft2
Note: Base layers of insulation shall be mechanically attached using the fastener density listed.
The insulation panels listed are minimum sizes and dimensions; if larger panels are used, the
number of fasteners shall be increased maintaining the same fastener density. Insulation fasteners
shall be tested for withdrawal resistance in compliance with Protocol TAS 105 to confirm
compliance with the wind load requirements. Please refer to Roofing Application: Standard RAS
117 for insulation attachment. GAF requires either a ply of GAFGLAS® STRATAVENT®
EWninatorTm perforated laid dry or a layer of EnergyGuardTM Perlite or wood fiber overlay
board on all poWsocyanurate applications.
Top Insulation Layer Insulation Fasteners Fastener
Any of the insulation listed for Base Layer, above. (Table 3) Density/ft2
Any
High Density Wood Fiber, Structodek®, Structodek® TD, EnergyGuardTM Recover Board
Minimum 1/" thick N/A N/A
Note: Optional top layer of insulation shall be adhered with approved asphalt within the EVT
range and at a rate of 20-40 lbs/100 ft2. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. Composite insulation boards used as a top layer shall be installed with the
polyisocyanyrate"face down.
Fire Barrier: FireOutTM Fire Barrier Coating, VersaShield®Non-Asphaltic Fiberglass -Based
(optional) Underlayment or SecurockTM.
NOA No.: 09-0224.01
MIAWFDADECOUNTY Expiration Date: 11/06/13
Approval Date: 04/08/09
Page 15 of 31
Base Sheet: (Optional) Install one ply of GAFGLAS® #75, GAFGLAS® #80 ULTIMATM Base
Sheet, GAFGLAS® PLY 4, GAFGLAS® Flex P1y1m 6, GAFGLAS®
STRATAVENT' Eliminatofrm Perforated (laid dry), RUBEROID® Modified Base
Sheet, RUBEROID® MOP Smooth or RUBEROID° 20 directly over the top layer
of insulation. Adhere with any approved mopping asphalt applied within the EVT
range and at a rate of 20-40 lbs./sq; (see.General Limitation #4).
Ply Sheet: (Optional) One or more plies GAFGLAS® PLY 4, GAFGLAS Flex Ply' 6 sheet
or GAFGLAS® #80 ULTUVIATM adhered in a full mopping of approved asphalt
applied within the EVT range and at a rate of 2040 lbsJsq.
Membrane: One or more plies of RUBEROID® 20i RUBEROV 30, RUBEROID®EnergyCap
SBS 30 FR RUBEROID®30 FR RUBEROID® MOP Smooth, RUBEROV Mop
170 FR, RUBEROV Mop Granule, Roof MatchTM SBS Mop Granular
RUBEROID® MOP PLUS, RUBEROID® MOP FR, RUBEROID® Dual FR or
RUBEROV ULTRACLAe SBS, fully adhered in an approved asphalt at an
application rate of 25 lb./sq. f I S%.
Surfacing: (Optional, required if RUBEROV MOP Smooth or RUBEROID® 20 is top
membrane) Install one of the following:
l Gravel or slag applied at 400 lbs./sq.. and 3001bs./sq. respectively in a flood
coat of approved asphalt at 60 lbs./sq. or applied in a flood coat of Leak
BusterTM MatrixTM 103 Cold Process Adhesive applied at a rate of 3 gal./sq.
2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral
Surfaced Capsheet adhered in a full mopping of approved asphalt applied
within the EVT range and at a rate of 20-40 lbsJsq.
3. Leak Bustefm MatrixTM 303 Premium Fibered Aluminum Roof Coating, at
1.5 gal./sq.
4. Leak Bustefm MatrixTM 715, Leak Busteim MatrixTM 322, TOPCOAT®
MB+, TOPCOAT' Fireshield Elastomeric Roofing Membrane, applied at I to
1.5 gal./sq.
5. Leak Bustefrm MatrixTM 602 MB Xtra EIastomeric Roofing Membrane,
EnergyCoteo roof coating applied at 1 to 1.5 galJsq.
6. -TOPCOAT® Surface Seal, TOPCOAT' Fireshiele SB Solvent based
Elastomeric Roofing Membrane applied at Ito 1.5 galJsq
7. Advance Green Technologies Photovoltaic Laminate solar energy collector
auxiliary roof equipment installed in compliance with manufacturer's
specifications and applicable Building Codes. .
Maximum Design
Pressure: 45 psf; (See General Limitation #7)
NOA No.: 09-0224.01
MIAMFWIDE COUNTY
Expiration Date: 11/06/13
• Approval Date: 04/08/09
Page 16 of 31
}
Membrane Type: APP/SBS Heat Weld
Deck Type 1I: Wood, Insulated
Deck Description: 19/32" or greater plywood or wood plank.
System Type B(2): Optional base sheet laid dry; base layer of insulation mechanically fastened,
optional top layer adhered with approved asphalt.
All General and System Limitations shall apply.
One or more layers of any of the following insulations.
Base Insulation Layer Insulation Fasteners
Fastener
(Table 3)
Density/ft,
EnergyGuardTM RA
Minimum 1.3" thick 1, 2, or 3
1:3 ft2
EnergyGuardTM RN
Minimum 1.4" thick 1, 2, or 3
1:3 R
EnergyGuardTM
Minimum 1.3" thick 1, 2, or 3
1:3 ftz
EnergyGuardTM Composite EnergyGuardTM RA Composite
Minimum 1.5" thick 3
1:3 ft2
EnergyGuardTM Perlite
Minimum 3/" thick 1, or 3
1:2 ft2
Wood Fiber, EnergyGuardTM Fiberboard, Structodek®, Structodek® TD
Minimum 1" thick 1, 2, or 3
1:2 ft2
Note: Base layers of insulation shall be mechanically attached using the fastener density listed.
The insulation panels listed are minimum sizes and dimensions; if larger panels are used, the
number of fasteners shall be increased maintaining the same fastener density. Insulation fasteners
shall be tested for withdrawal resistance in compliance with Protocol TAS 105. to confirm
compliance with the wind load requirements. -Please refer to Roofing Application Standard RAS
117 for insulation attachment. GAF requires either'a ply of GAFGI " STRATNVENT*
EliminatorTM perforated laid dry or a layer of EnergyGuardTM Perlite or wood fiber overlay board
on all polyisocyanurate applications.
Top Insulation Layer
Fastener
Density/ft?
Any of the insulation listed for Base Layer, above.
High Density Wood Fiber, Structodek®, Structodek® TD, EnergyGuardTM Recover Board
Minimum'/2" thick N/A
Insulation Fasteners
(Table 3)
N/A
Note: Optional top layer of insulation shall be adhered with approved asphalt within the EVT
range and at a rate of 20-40 lbs/100 W. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. Composite insulation boards used as a top layer shall be installed with the
polyisocyanurate face down.
Fire Barrier: FireOutTM Fire Barrier Coating, VersaShield®Non-Asphaltic Fiberglass -Based
(optional) Underlayment or SecurockTM.
NOA No.: 09-0224.01
Expiration Date: 11/06/13
Approval Date: 04/08/09
Page 17 of 31
Base Sheet:
Install one ply of GAFGLAS® #75, GAFGLAS® #80 ULTIMA' Base Sheet,
GAFGLAS® PLY 4, GAFGLAS® Flex Ply "" 6, GAFGLAS® STRATAVENT®
Eliminatofm Perforated (laid dry), RUBEROID® Modified Base Sheet,
RUBEROID® MOP Smooth, RUBEROID® 20, RUBEROID® SBS Heat-We1dTM
Smooth or RUBEROV SBS Heat-WeldTM 25 directly over the top layer of
insulation. Adhere with any approved mopping asphalt applied within the EVT
range and at a rate of 20-40 lbsJsq; (see General Limitation #4).
Ply Sheet:
(Optional, required when using RUBEROID® 20) One or more plies GAFGLAS®
PLY 4, GAFGLAS® Flex PIyTM 6 sheet or GAFGLAS® #80 ULTIMATM adhered
in a full mopping of approved asphalt applied within the EVT range and at a rate
of 20-40 lbsJsq.
Membrane:
One ply of RUBEROID® Torch Smooth, RUBEROID® Torch Granule, Roof
MatchTM APP Torch Granule, RUBEROID® EnergyCapTM Torch Granule FR,
RUBEROID® Torch Plus Granule or RUBEROW0 Torch FR, RUBEROID®
EnergyCaplm Torch Plus FR torch applied according to manufacturer's application
instructions.
Or
One or more plies of RUBEROV SBS Heat-WeldTM PLUS, RUBEROID® SBS
Heat-WeIdTM PLUS FR, RUBEROID® SBS Heat WeldTM 170 FR, RUBEROID®
EnergyCapTM SBS Heat-WelldTM Plus FR, RUBEROID® SBS Heat-WeldTM,
RUBEROID® SBS Heat-We1dTM Smooth, RUBEROMP ULTRACLAD® SBS and
RUBEROID® SBS Heat-WeldTM 25 applied according to manufacturer's
application instructions.
Surfacing:
(Optional, required if RUBEROID® MOP Smooth or RUBEROV 20 is • top
membrane) Install one of the following:
1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood
coat of approved asphalt at 60 lbsJsq. or applied in a flood coat of Leak
BusterTM MatrixTM- 103 Cold Process Adhesive applied at a rate of 3 galJsq.
2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral
Surfaced Capsheet adhered in a full mopping of approved asphalt applied
within the EVT range and at a rate of 20-40 lbsJsq. .
3... Leak BusterTM MatrixTM 303, Premium Fibered Aluminum Roof Coating, at
1.5 galJsq.
4. Leak BusterTM MatrixTM 715, Leak BusterTM MatrixTM 22, TOPCOAT® MB+,
TOPCOAT' Fireshield Elastomeric Roofing Membrane, applied at 1 to 1.5
gal./sq.
5. Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane,
EnergyCoteo roof coating applied, at 1 to 1.5 gal./sq.
6. TOPCOAT® Surface Seal, TOPCOAT' Fireshieie SB Solvent based
Elastomeric Roofing Membrane applied at Ito 1.5 galJsq
7. Advance Green Technologies Photovoltaic Laminate solar energy collector
auxiliary roof equipment installed in compliance with manufacturer's
specifications and applicable Building Codes.
Maximum Design
.
Pressure:
-45 psf;(See General Limitation #7)
NOA No.:. 09-0224.01
MMWMDECO-UNWM Expiration Date: 11/06/13
• Approval Date: 04/08/09
Page 18 of 31
E
Membrane Type: SBS
Deck Type 1I: Wood, Insulated
Deck Description: 7/$211 or greater plywood or wood plank
System Type C(1): One or more -layers of insulation simultaneously attached; Base layer optional.
All General and System Limitations shall apply.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/fe
EnergyGuardTM RA, EnergyGuardTM RN
Minimum 1.3" thick N/A N/A
EnergyGuardm
Minimum 1.4" thick
EnergyGuardTM Composite, EnergyGuardTM RA Composite
Minimum 1.5" thick n
EnergyGuardTM Perlite
Minimum 3/4" thick
Wood Fiber, EnergyGuardTM Fiberboard
Minimum 1" thick
NIA N/A
N/A . N/A
N/A - N/A
N/A N/A
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density.
Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number
of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing .
Application Standard RAS 117 for insulation attachment.
Top Insulation Layer Insulation Fasteners Fastener
EnergyGnard RA (Table 3) Density/fla
Minimum 1.3" thick 1, 2, or 3 1:3 ft2
EnergyGuardTM RN
Minimum 1.4" thick 1, 2, or 3 13 ft2
EnergyGuardTm RA, EnergyGuard
Minimum 1 Y' thick 1, 2, . or 3 1:3 ft2
EnergyGuard, Composite, EnergyGuardTM RA Composite
Minimum 1.5" thick 3 1:3 ft2
EnergyGuardTM Perlite
Minimum 3/4" thick 1, or 3 1:2 ft2
EnergyGuardTM Fiberboard, StrnctodeO, Structodek® TD
Minimum 1" thick 1, 2, or 3 1:2 ft2
Note: Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the
number of fasteners shall be increased maintaining the same fastener density. Please refer to
Roofing Application Standard RAS 117 for insulation attachment. GAF requires either a ply of
GAFGLAe STRATAVENT®EliminatorTM Perforated laid dry or a layer of EnergyGuardTM
Perlite or wood fiber overlay board on all polyisocyanurate applications.
NOA No.: 09-0224.01
r+uuHFnnaecoM Expiration Date: 11/06/13
• Approval Date: 04/08/09
Page 19 of 31
Fire Barrier:
(optional)
FireOutTM Fire Barrier Coating, VersaShield® Non -Asphaltic Fiberglass -Based
Underlayment or SecurockTM.
Base Sheet:
Install one ply of GAFGLAS® #75, GAFGLAS® #80 ULTIIVIA TM Base Sheet
GAFGLAS® PLY 4, GAFGLAS® FlexPlyw 6, GAFGLAS® STRATAVENT®
Perforated (laid dry), RUBEROID® Modified Base Sheet, RUBEROID® MOP
Smooth or RUBEROID® 20 directly over the top layer of insulation. Adhere with
any approved mopping asphalt applied within the EVT range and at a rate of 20-40
lbs./sq. If base sheet is applied directly to polyisocyanurate insulation only a spot
or strip mopped application as detailed in this approval the use of an overlay board
is approved, (see General Limitation #4).
Ply Sheet:
(Optional) One or more plies GAFGLAS® PLY 4, GAFGLAS® Flex PIyTM 6 sheet
or GAFGLASO #80
ULTIMA' adhered in a full mopping of approved asphalt
applied within the EVT range and at a rate of 20-40 lbs./sq.
Membrane:
One or more plies of RUBEROID® 20, RUB EROID® 30, RUBEROID®
EnergyCap ® SBS 30 FR,RUBEROID® 30 FR, RUBEROM@ MOP Smooth,
RUBEROID Mop
170 FR, RUBEROM' Mop Granule, Roof MatchTM SBS
Mop Granule, RUBEROID® MOP PLUS, RUBEROID® MOP FR, RUBEROV
Dual FR or RUBEROID® ULTRACLAD® SBS, fully adhered in an approved
asphalt at an application rate of 20-40 lbs./sq.
Surfacing:
(Optional, required if RUBEROID® MOP Smooth or RUBEROV 20 is top
membrane) Install one of the following:
I. Gravel or slag applied at 4001bsJsq. and 300 lbs./sq, respectively in a flood
coat of approved asphalt at 601bsJsq. or applied in a flood coat of Leak
BusterTM MatrixTM 103 Cold Process Adhesive applied at a rate of 3 gal./sq.
2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral
Surfaced Capsheet adhered in a full mopping of approved asphalt applied
within the EVT range and at a rate of 2040 lbsJsq. '
3. Leak BusterTM-MatrixTM 303 Premium Fibered Aluminum Roof Coating, at
1.5. galJsq.
4. Leak BusterTM MatrixTM 715, Leak BusterTM MatrixTM 322, TOPCOAT®
MB+, TOPCOAT' Fireshield Elastomeric Roofing Membrane, applied at l
to 1.5 galJsq.
5. Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane,
EnergyCote®roof coating applied at 1 to 1.5 galJsq.
6. TOPCOAT' Surface Seal, TOPCOAT® Fireshield® SB Solvent based
Elastomeric Roofing Membrane applied at Ito 1.5 galJsq
7. Advance Green Technologies Photovoltaic Laminate solar energy collector
auxiliary roof equipment installed in compliance with manufacturer's
specifications and applicable Building Codes. .
Maximum Design
Pressure:
-45 psf,(See General Limitation #7)
NOA No.: 09-0224.01
MAMI-DADECouNTY Expiration Date: 11/06/13
�RWZ[61741Approval Date: 04/08/09
Page 20 of 31
1 t �
Insulation Fasteners Fastener
(Table 3) Density/fe
N/A N/A
N/A N/A
N/A N/A
N/A N/A
EnergyGuardTM Fiberboard
Minimum 1" thick N/A N/A
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density.
Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number
of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing
Application Standard RAS 117 for insulation attachment.
Top'Insulation Layer
EnergyGuardTM RA
Minimum 1.3" thick
EnergyGuardTM RN
Minimum 1.4" thick
EnergyGuarem
Minimum 1.3" thick
EnergyGuard7m Composite, EnergyGuardlm RA Composite
Minimum 1.5" thick
EnergyGuardTM Perlite
Minimum :%" thick
EnergyGuardTM Fiberboard, Structodek®, StructodeV TD
Minimum I" thick
Membrane Type:
Deck Type 1I:
Deck Description:
System Type C(2):
APP/SBS Heat Weld
Wood, Insulated
79
/32" or greater plywood or wood plank
One or more layers of insulation simultaneously attached; Base layer optional.
AB General and System Limitations shall apply.
Base Insulation Layer
EnergyGuardTM, EnergyGuardTM RA, EnergyGuardTM RN
Minimum 1.3" thick
EnergyGuardTM
Minimum 1.4" thick
EnergyGuardTM Composite, EnergyGuardTM RA Composite
Minimum 1.5" thick
EnergyGuardTM Perlite, EnergyGuardTM Recover Board
Minimum %" thick
Insulation Fasteners Fastener
(Table 3) Density/ft2
1, 2, or 3 1:3 ft2
1,2,or3 .1:3fV
1; 2, or 3 1:3 ft2
3 I :3 ft2
1,or3 1:2.ft2
1,2or3 1:2R2
Note: Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the
number of fasteners shall be increased maintaining the same fastener density. Please refer to
Roofing Application Standard RAS 117 for insulation attachment. GAF requires either a ply of
GAFGLAS® STRATAVENT® EliminatorTM Perforated laid dry or a layer of EnergyGuardTM
Perlite or wood fiber overlay board on all polyisocyanurate applications.
APPROVED
NOA No.: 09-0224.01
Expiration Date: 11/06/13
Approval Date: 04/08/09
Page 21 of 31
Fire Barrier:
(optional)
FireOutl Fire Barrier Coating, VersaShield® Non -Asphaltic Fiberglass -Based
Underlayment or SecurockTM.
Base Sheet:
Install one ply of GAFGLAS® #75, GAFGLAS® #80 ULTIMA TM Base Sheet
GAFGLAS® PLY 4, GAFGLAS® F1exPlyTM 6, GAFGLAS®
STRATAVENr
EliminatorTM Perforated (laid dry), RUBEROID® Modified Base Sheet,
RUBEROID® MOP Smooth or RU13EROIDO 20 directly over the top layer of
insulation. Adhere with any approved mopping asphalt applied within the EVT
range and at a rate of 20-40 lbs./sq. If base sheet is applied directly to
polyisocyanurate insulation only a spot or strip mopped application as detailed in
this approval the use of an overlay board is approved; (see General Limitation
#4).
Ply Sheet:
(Optional, required when using RUBEROID® 20) One or more plies GAFGLAS®
PLY 4, GAFGLAS® Flex
P1yTM 6 sheet or GAFGLAS® #80 ULTIMATM adhered
in a full mopping of approved asphalt applied within the EVT range and at a rate
of 20.40 lbs./sq.
Membrane:
One ply of RUBEROID® Torch Smooth, RUBEROID® Torch Granule, Roof
MatchTM APP Torch Granule, RUBEROID® Torch Plus Granule, RUBEROV
EnergyCapTM Torch Granule FR, RUBEROV
EnergyCapTM Torch Plus FR, or
RUBEROID® Torch FR torch applied according to manufacturer's application
instructions.
Or
One or more plies of RUBEROID® SBS Heat-WeldTM PLUS, RUBEROID11 SBS
Heat-WeldTM PLUS FR, RUBEROID® SBS Heat-WeldTM 170 FR, RUBEROV
EnergyCapTM SBS Heat-WeldTM
Plus FR, RUBERO.ID® SBS Heat WeldTM,
RUBEROID® SBS Heat-WeldTM Smooth, RUBEROIDO ULTRACLAD SBS
and
RUBEROID® SBS Heat-WeldTM 25 applied according to manufacturer's
application.instructions.
Surfacing:
(Optional, required if RUBEROID® MOP Smooth or RUBEROID® 20 is top
membrane) Install one of the following:
1. Gravel or slag applied at 400 lbsJsq. and 3001bsJsq. respectively in a flood
coat of approved asphalt at 601bs./sq. or applied in a flood coat of Leak
BusteiTM MatrixTM 103 Cold Process Adhesive applied at a rate -of 3 gaUsq.
2. GAFGLAS® Mineral
Surfaced Cap Sheet, .GAFGLAS® Energy Cap Mineral
Surfaced Capsheet adhered in a full mopping of approved asphalt applied
within the EVT range and at a rate of 20-401bsJsq.
3. Leak BusterTM MatrixTM 303 Premium Fibered Aluminum Roof Coating, at
1.5 gal./sq.
4. Leak BusterTM MatrixTM 715, Leak BusterTM MatrixTM 322, TOPCOAT®
.
MB+, TbPCOAT Fireshield Elastomeric Roofing Membrane, applied at 1 to
1.5 galJsq..
5. Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane,
EnergyCotO roof coating applied at I to 1.5 gal./sq2.
6. TOPCOATS'
Surface Seal, TOPCOAT' Fireshield SB Solvent based
Elastomeric Roofing Membrane applied at Ito 1.5 galJsq
7. Advance Green Technologies Photovoltaic Laminate solar energy collector
auxiliary roof equipment installed in compliance with manufacturer's
Maximum Design
specifications and applicable Building Codes.
Pressure:
45 psf;(See General Limitation #7)
ffflMILE WCOUNW
9 . 0
NOA No.: 09-0224.01
Expiration Date: 11/06/13
Approval Date: 04/08/09
Page 22 of 31
Membrane Type: SBS/SBS Cold Applied
Deck Type 1I: Wood, Insulated
Deck Description: 19/32 or greater plywood or wood plank
System Type D(1): Insulation and Base sheet simultaneously attached
All General and System Limitations shall apply.
One or more layers of any of the following insulations.
Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/fe
EnergyGuardTM, EnergyGuardTM RA, EnergyGuardTM RA, EnergyGuardTM Composite,
StructodeV, StructodeV TD, EnergyGuardTM Fiberboard
Minimum I" thick N/A N/A
Fire Barrier: FireOutTM Fire Barrier Coating, VersaShieieNon-Asphaltic Fiberglass -Based
(optional) Underlayment or SecurockTM.
Base Sheet: Install one ply of GAFGLAS® #75, GAFGLAS® #80 ULTIMArM Base Sheet,
GAFGLAS® STRATAVENT" Eliminatofm Perforated or RUBEROID® 20 base
sheet applied over the loose laid insulation with 2" side laps'mechanically fastened
to deck as described below;
Fastening Options: Drill-TecTM # 12 standard, #14 or # 15 Screws and 3" Drill.-TecTM steel plate or
Drill-TecTM.AccuTrac Plates are installed through the base sheet and insulation in
3 rows 12" o.c. One row is in the 2" side lap. The other rows are equally spaced
approximately 12" o:c. in the field of the sheet.
(Maximum Design Pressure —45 psf, See General Limitation #7)
GAFGLAS® #80 ULTIMATM, RUBEROID® 20, RUBEROID® Mop Smooth, base
sheet attached to deck with approved annular ring shank nails and tin caps at a
fastener spacing. of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the
field.
(Maximum Design Pressure -=60 psf, See General Limitation #7)
Drill-TecTM #12 standard, #14 or # 15 Screws and3" Plates in 4 rows 12" O.C.
One row is in the 2" side lap. The other rows are equally spaced approximately
9" O.C. in the field of the sheet.
(Maximum Design Pressure —60 psf, See General Limitation #7)
Drill-TecTM 912 standard, #14 or # 15 Screws and 3" Drill-Tedm steel plate or
Drill-TeOm AccuTrac Plates are installed through the base sheet and insulation in
4 rows 8" o.c. One row is in the 2" side lap. The other 3 rows are equally spaced
approximately 9" o.c. in the field of the sheet.
(Maximum Design Pressure —75 psf, See General Limitation #7)
Ply Sheet: (Optional) One or more plies GAFGLAS® PLY 4, GAFGLAS® Flex Plym 6 sheet,
GAFGLAS® #80 UltimaTM, RUBEROID® MOP Smooth or RUBEROID® 20
adhered in a full mopping of approved asphalt applied within the EVT range and at
a rate of 20-40 lbs./sq.
NOA No.: 09-0224.01
Expiration Date: 11/06/13
Approval Date: 04/08/09
Page 23 of 31
Membrane: 'One or more lies of RUBEROID® MOP Smooth, RUBEROID® Mop 170 FR,
RUBEROID�Mop Granule, Roof Matchrm SBS Mop Granule, RUBEROID® Mop
Plus Granule, RUBEROID020, RUBEROID030, RUBEROID®EnergyCap SBS
30 FR, RUBEROID® 30 FR or RUBEROID® Mop FR or RUBEROV
ULTRACLAD® SBS in adhered.in a full mopping of approved asphalt applied
within the EVT range and at a rate of 20401bs./sq.
Or,
One or more plies of RUBEROID® MOP Smooth, RUBEROV Mop Granule,
Roof MatchTM SBS Mop Granule, RUBEROID® Mop 170 FR, RUBEROV Mop
Plus Granule, RUBEROID020, RUBEROID® 30, RUBEROV EnergyCapTM
SBS 30 FR, RUBEROV 30 FR or RUBEROID® Mop FR or RUBEROID®
ULTRACLAI)e SBS in Leak BusterTM MatrixTm 102 SBS Adhesive at an
application rate of 1-2 gaUsq.
Surfacing: (Optional, required if RUBEROV MOP Smooth or RUBEROV 20 is top
membrane) Install one of the following:
1. Gravel or slag applied at 400 lbs./sq. and 300 lbsJsq. respectively in a flood
coat of approved asphalt at 601bs./sq. or applied in a flood coat of Leak
BusterTM MatrixTM 103 Cold Process Adhesive applied at a rate of 3 gal./sq.
2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral
Surfaced Capsheet adhered in a full mopping of approved asphalt applied
within the EVT range and at a rate of 20-40 lbs./sq.
3. Leak BusterTM Matri elm 303 Premium Fibered Aluminum Roof Coating, at
1:5 gaUsq.
4. .Leak BusterTM MatrixTM 715, Leak BusterTM MatrixTM 322, TOPCOAT'
MB+, TOPCOAT' Fireshield Elastomeric Roofing Membrane, applied at 1 to
1.5 gal./sq.
5. Leak Busteim MatrixTM 602 MB Xtra Elastomeric Roofing Membrane,
EnergyCote® roof coating applied at 1 to 1.5 gal./sq.
6. TOPCOAr Surface Seal, TOPCOAT® Fireshieie SB Solvent based
Elastomeric .Roofing Membrane applied at Ito 1.5 galJsq
7. Advance Green Technologies Photovoltaic Laminate solar energy collector
auxiliary roof equipment installed in compliance with manufacturer's
specifications and applicable Building Codes.
Maximum Design
Pressure: See Fastening above
NOA No.: 09-0224.01
Expiration Date: 11/06/13
hiU►Mwane couNTr Approval Date: 04/08/09
Page 24 of 31
Membrane Type: APP/SBS Heat Weld
Deck Type 1I: Wood, Insulated
Deck Description: 19/32" or greater plywood or wood plank
System Type D(2): Insulation and Base sheet simultaneously attached
All General and System Limitations shall apply.
One or more layers of any of the following insulations.
Insulation Layer Insulation Fasteners Fastener
EnergyGuardTM, EnergyGuardTM RA, EnergyGuardrK Composite, able 3) Density/ftz
Minimum 1.3" thick N/A N/A
Structodek®, Structodek® TD, EnergyGuardrm Fiberboard
Minimum 1" thick N/A N/A
Fire Barrier: FireOutTM. Fire Barrier Coating, VersaShield® Non -Asphaltic Fiberglass -Based
(optional) Underlayment or SecurockTM.
Base Sheet: Install one ply of GAFGLAS® #75, GAFGLAS® #80 ULTIMA'M Base Sheet,
GAFGLAS® ST IATAVENT® EliminatorTM Perforated or RUBEROIDO 20 base
sheet applied over the loose laid insulation with 2" side laps mechanically fastened
to deck as described below;
Fastening Options: Drill-TecTM #12 standard, #14 or # 15 Screws and 3" Drill-TecTM steel plate or
Drill-TecTM AccuTrac Plates are installed through the base sheet and insulation in
3 rows 12" o.c. One row is. in the 2" side lap. The other rows are equally spaced
approximately 12" o.c. in the field of the sheet.
(Maximum Design Pressure —45 psf, See General Limitation #7)
GAFGLAS® #80 ULTIMATM, RUBEROID®20, RU13EROID®Mop Smooth, base
sheet attached to deck with approved annular ring shank nails and tin caps ata'
fastener spacing of 9" �o.c. at the 4" lap staggered and in two rows 9" o.c. in the
field.
(Maximum Design Pressure —60 psf, See General Limitation #7)
Drill-TecTM #12 standard, #14 or # 15 Screws and 3" Drill-TecTM steel plate or
Drill-TecTM AccuTrac Plates in 4 rows 12" o.c. One row is in the 2" side lap.
The other rows are equally spaced approximately.9" o.c. in the field of the sheet.
(Maximum Design Pressure —60 psf, See General Limitation #7)
Drill-TecTM #12 standard, #14 or # 15 Screws and 3" Plates are installed through
the base sheet and insulation in 4 rows 8" o.c. One row is in the 2" side lap. The
other 3 rows are equally spaced approximately 9" o.c. in the field of the sheet.
(Maximum Design Pressure —75 psf, See General Limitation #7)
Ply Sheet: (Optional,'required when using RUBEROV 20) One or more plies GAFGLAS®
PLY 4, GAFGLAS® Flex PlyTM 6 sheet or GAFGLAS®#80 ULTIMATM adhered
in a full mopping of approved asphalt applied within the EVT iange and at a rate
of 20-40 lbs./sq.
NOA No.: 09-0224.01
Muu�4naoEcouHrY Expiration Date: 11/06/13
Approval Date: 04/08/09
Page 25 of 31
Membrane:
One ply of RUBEROID® Torch Smooth, RUBEROID® Torch Granule, Roof
MatchTM APP Torch Granule, RUBEROID® EnergyCapTM Torch Granule FR,
RUBEROID® Torch Plus Granule, RUBEROV EnergyCapTM
Torch Plus FR, or
RUBEROID® Torch FR torch applied according to manufacturer's application
instructions.
Or
One or more plies of RUBEROID® SBS Heat-WeIdTM PLUS, RUBEROID® SBS
Heat-WeIdTM PLUS FR, RUBEROID® SBS Heat WeIdTM 170 FR, RUBEROM0
EnergyCap SBS Heat WeIdTM PLUS FR, RUBEROID® SBS Heat-WeIdTM,
RUBEROV SBS Heat-WeIdTM Smooth, RUBEROID®ULTRACLAD® SBS and
RUBEROID®.SBS
Heat WeIdTM 25 applied according to manufacturer's
application instructions.
Surfacing:
(Optional, required if RUBEROID® MOP Smooth or RUBEROID® 20 is top
membrane) Install one of the following:
1. Gravel or slag applied at 400 Ibs./sq. and 300 lbs./sq: respectively in a flood
coat of approved asphalt at 60 lbs./sq. or applied in a flood coat of Leak
BusterTM MatrixTM 103 Cold Process Adhesive.applied at a rate of 3 gal./sq.
2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral
Surfaced Capsheet adhered in a full mopping of approved asphalt applied
within the EVT range and at a rate of 20-401bs./sq'.
3. Leak BusterTM MatrixTM 303 Premium Fibered Aluminum Roof Coating, at
1.5 galJsq.
4. Leak BusterTM MatrixTM 715, Leak BusterTM MatrixTM 322, TOPCOAT'
MB+, TOPCOAT' Fireshield Elastomeric Roofing Membrane, applied at 1.
to 1.5 galJsq.
5. Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane,
EnergyCoteo roof coating applied at 1 to 1.5 gal./sq.
6. TOPCOAT' Surface Seal, TOPCOAT® Fireshiele SB Solvent based
Elastomeric Roofing Membrane applied at Ito 1.5 galJsq
7. Advance Green Technologies Photovoltaic Laminate solar energy collector
auxiliary roof equipment installed in compliance with manufacturer's
Maximum Design
specifications and applicable Building Codes.
Pressure:
See Fastening Above
NOA No.: 09-0224.01
MIAWDADEC2U Expiration Date: 1VO6113
Approval Date: 04/08/09
Page 26 of 31
Membrane Type: SBS/SBS Cold Applied
Deck Type 1: Wood, Non -insulated
Deck Description: 19/32" or greater plywood or wood plank decks
System Type E(1): Base sheet mechanically fastened to roof deck.
All General and System Limitations shall apply.
Fire Barrier: FireOutTM Fire Barrier Coating, VersaShield® Non -Asphaltic Fiberglass -Based
(optional) Underlayment or SecurockTM.
Base sheet: GAFGLAS" #80 ULTIMA TM Base Sheet, STRATAVENr EliminatorTM
Nallable, RUBEROID® Modified Base Sheet, RU_ BEROID®, 20,.RUBEROID®.........._
SBS Heat-WeldTM Smoothor RUBEROID� SBS Heat-WeldTM 25 base sheet
mechanically fastened to deck as described below;
Fastening GAFGLASO Ply 4, GAFGLAS" Flex P1yTM 6, GAFGLAS® #75 Base Sheet or any
Options: of above Base sheets attached to deck with approved annular ring shank nails and
tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12"
o.c. in the field.
(Maximum Design Pressure —45 psf, See General Limitation #�
GAFGLAS® Ply 4, GAFGLAS® Flex PlyTM 6, GAFGLAS® #75 Base Sheet .or any
of above Base sheets attached to deck with Drill-Teerm #12 standard, #14 or # 15
Screws and 3" DrilI-TecTM steel plate or Drill-TecTM AccuTrac Plates, 12 o.c. in
3 rows. One row is in the 2" side lap. The other rows are equally spaced
approximately 12" o..c. in the field of the sheet.
(Maximum Design Pressure.-45 psf, See General Limitation #7)
GAFGLAS® Flex PIyTM 6, GAFGLAS® #75 Base Sheet or any of above Base
sheets attached to deck with approved annular ring shank nails and tin caps at a
fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the
field.
(Maximum Design Pressure 52. S psf, See General Limitation #7
GAFGLAS® #80 ULTIMATM; RUBEROV20, RUBEROVMop Smooth, base
sheet attached to deck with approved annular ring shank nails and tin caps at a
fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the
field.
(Maximum Design Pressure —60 psf, See General Limitation #7)
GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with
Drill-TecTM #12 standard, #14 or # 15 Screws and 3" Drill-TecTM steel plate or
Drill-TecTM AccuTrac Plates, 12" o.c. in 4 rows. One row is in'the 2" side lap.
The other rows are equally spaced approximately 9" o.c. in the field of the sheet.
(Maximum Design Pressure —60 psf, See General Limitation #7)
Any of above Base sheets attached to deck approved annular ring shank nails and
3" inverted Drill-TecTM insulation plates at a fastener spacing of 9" O.C. at the 4"
lap staggered in two rows 9" in the field.
(Maximum Design Pressure —60 psf, See General Limitation #7
NOA No.: 09-0224.01
LMMAMWnE
eoutar�r utar�rExpiration Date: 11/06/13
' ' Approval Date: 04/08/09
Page 27 of 31
C11
GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with
Drill-TecTM #12 standard, #14 or # 15 Screws and 3" Drill-TecTM steel plate or
Drill-TecTM AccuTrac Plates, 8" o.c. in 4 rows. One row is in the 2" side lap. The
other rows are equally spaced approximately 9" o.c. in the field of the sheet.
(Maximum Design Pressure —75 psf, See General Limitation #7)
Ply Sheet: (Optional) One or more plies GAFGLAS® PLY 4, GAFGLAS® Flex P1yTM 6,
GAFGLAS® #80, RUBEROID® MOP Smooth or RUBEROID® 20 sheet adhered
in a full mopping of approved asphalt applied within the EVT range and at a rate
of 20-40 ]Wsq.
Membrane: One or more plies of RUBEROV MOP Smooth, RUBEROID® Mop 170 FR,
RUBEROV Mop Granule, Roof MatchTM SBS Mop Granule, RUBEROMPMop
Plus Granule, RUBEROID020, RUBEROID®30, RUBEROID®EnergyCap SBS
30 FR RUBEROID) 3 0 FR or RUBEROID® Mop FR or RUBEROID
ULTRACLAD® SBS in adhered in a full mopping of approved asphalt applied
within the EVT range and at a rate of 2040 lbs./sq.
Or,
One or more.plies of RUBEROID® MOP Smooth, RUBEROID® Mop Granule,
Roof MatchTM SBS Mop Granule, RUBEROID® Mop 170 FR, RUBEROV Mop
Plus Granule, RUBEROV 20, RUBEROV 30, RUBEROID®EnergyCap SBS
30 FR, RUBEROV 30 FR or RUBEROID® Mop FR or RUBEROV
ULTRACLAD® SBS in Leak Bustefm MatrixTM 102 SBS Adhesive at an
application rate of 1-2 galJsq.
Surfacing: (Optional, required if RUBEROID® MOP Smooth or RUBEROV 20 is top
membrane) Install one of the following:
1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood
coat. of approved asphalt at 60 lbs./sq. or applied in a flood coat of Leak
BusterTM MatrixTm 103 Cold Process Adhesive applied at a rate of 3 galJsq.
2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral
Surfaced Capsheet adhered in a full mopping of approved asphalt applied
within the EVT range, and at a rate of 20401bs./sq.
3. Leak Bustefrm Matri2JM303 Premium Fibered Aluminum Roof Coating, at 1.5
gaJsq•
4. Leak BusterTM MatrixTM 715, Leak BusterTM Matrixrm 322, TOPCOAT'
MB+, TOPCOAT' Fireshield Elastomeric Roofing Membrane, applied at 1 to
1.5 gal./sq.
5. Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane,
EnergyCote® roof coating applied at 1 to IS gal./sq.
6. TOPCOAT® Surface Seal, TOPCOAT® Fireshieie SB Solvent based
Elastomeric Roofing Membrane applied at Ito 1.5 galJsq
7. Advance Green Technologies Photovoltaic Laminate solar energy collector
auxiliary roof equipment installed in compliance with manufacturer's
specifications and applicable Building Codes.
Maximum Design
Pressure: See Fastening above
NOA No.: 09-0224.01
Expiration Date: 11/06/13
Approval Date: 04/08/09
Page 28 of 31
Membrane Type:
APp/SBS Heat Weld
Deck Type 1:
Wood, Non -insulated
Deck Description;
19/32" or greater plywood or wood plank decks
System Type E(2):
Base sheet mechanically fastened.
All General and System Limitations shall apply.
Fire Barrier:
(optional)
FireOutTM Fire Barrier Coating, VersaShieleNon-Asphaltic Fiber lass-Bas
Underlayment or SecurockTM. g ed
Base sheet:
GAFGLAS" #80 ULTIMATM Base Sheet, STRATAVENT®EliminatorTm
Na"able, RUBEROID" Modified
Base Sheet; RUBEROID" MOP Smooth,
RUBEROID" 20, RUBEROID" SBS Heat-We1dTM Smooth or RUBEROID"
Heat
Fastening Options:
SBS
-Weld 25 base sheet mechanically fastened to dec cribed below;
GAFGLAS" Ply 4, GAFGLAS® Flex P1yTM 6, t GLAS" #75 Base She or an
of above Base sheets attached to deck with approved annu
ar ring shank nails and
tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12"
O.C. in the field.
(Maximum Design Pressure -45 psf, See General Limitation V)
GAFGLAS® Ply 4, GAFGLAS Flex P1yTM 6, GAFGLAS" #75 Base Sheet or an
of above Base sheets attached to deck with Drill-Tec` #I2
standard, #14 or # 15
Screws and 3" Drill-TecTM steel plate
3 or Drill-TecTM AccuTrac Plates, 12" o.c. in
rows. One row is in the 2"
side lap. The other rows are equally spaced
approximately 12" o.c. in the field of the sheet.
(MarimumDe*n Pressure -45 psf, See General Limitation #�
GAFGLAS" Flex PIyTM 6, GAFGLAS" #75 Base Sheet or any of above Base
sheets attached to deck with approved annular ring shank nails and tin caps at a
fastener. spacing of 9" O.C. at the 4" I
field. ap staggered and in two rows 9" o.c. in the
(Maximum Design Pressure S2.5 psf, See General Limitation #,
GAFGLAS" #80 ULTIMA"M RUBER0I0"20, RUBEROID"Mop Smooth, base
sheet attached to deck with approved annular ring shank nails and tin caps at a
fastener spacing of 9" o.c. at the 4" lap staggered -and in two rows 9" o.c. in the
field.
(Maximum Design Pressure-60psf, See General Limitation #7)
GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with
Drill-TecTM #12 standard, #14 or # *15 Screws and 3" Drill-TecTM steel plate or
Drill-TecTM AccuTrac Plates, 12" o.c., in 4 rows. One row is in the 2" side lap.
The other rows are equally spaced approximately 9" O.C. in the field of the sheet.
(Maximum Design Pressure -60 psf, See General Limitation #/-9
Any of above Base sheets attached to deck approved annular ring shank nails and
3" inverted Drill-TecTM insulation plates at a fastener spacing of 9" o.c. at the 4"
lap staggered in two rows 9" in the field.
(Maximum Design Pressure -60 psf, See General Limitation #7)
MIAMIiNDECOr1N7Y NOA No.: 09-0224.01
• Expiration Date:.11106113
Approval Date: 04/08/09
Page 29 of 31
GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with
Drill-TecTM #12 standard, #14 or # 15 Screws and 3" Drill-TecTM steel plate or
Drill-TecTM AccuTrac Plates, 8" o.c. in 4 rows. One row is in the 2" side lap.
The other rows are equally spaced approximately 9" o.c. in the field of the sheet.
(Maximum Design Pressure —75 psf, See General Limitation #7)
Ply Sheet: (Optional except over RUBEROID® Modified Base Sheet, RUBEROID® MOP
Smooth, RUBEROID® 20, RUBEROID® SBS Heat-WeIdTM Smooth or
RUBEROID® SBS Heat-WeIdTM) One or more plies GAFGLAS® PLY 4 or
GAFGLAS® Flex P1yTM 6 sheet adhered in a full mopping of approved asphalt
applied within the EVT range and at a rate of 20-40 lbs./sq: or RUBEROID® Torch
Smooth torch applied according to manufacturer's application instructions.
Membrane: One ply of RUBEROID® Torch Smooth, RUBER®ID®rT U— anul Roof
MatchTM APP Torch Granule, RUBEROID® EnergyCapTM Torch Granule FR,
RUBEROID® Torch Plus Granule, RUBEROID® EnergyCapTM Torch Plus FR, or
RUBEROID® Torch FR torch applied according to manufacturer's application
instructions.
Or
One or more plies. of RUBEROID® SBS Heat-WeIdTM PLUS, RUBEROID® SBS
Heat-WeIdTM PLUS FR, RUBEROID® SBS Heat-WeIdTM 170 FR, RUBEROID®
EnergyCapTM SBS Heat-WeIdTM Plus FR, RUBEROID® SBS Heat-WeIdTM,
RUBEROID® SBS Heat-WeIdTM Smooth, RUBEROID® ULTRACLAD® SBS
and RUBEROID® SBS Heat-WeIdTM 25 applied according to manufacturer's
application instructions.
Surfacing: (Optional, required if RUBEROID® MOP Smooth or RUBEROID® 20 is top
membrane) Install one of the following:
1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood
coat of approved asphalt at 60 lbs./sq. or applied in a flood coat of Leak
BusterTM MatrixTM 103 Cold Process Adhesive applied at a rate of 3 gal./sq.
2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral
Surfaced Capsheet adhered in a full mopping of approved asphalt applied
within the EVT range and at a rate of 20-40 lbs./sq.
3. Leak BusterTM MatrixTM 303 Premium Fibered Aluminum Roof Coating, at
1.5 gal./sq.
4. Leak BusterTM MatrixTM 715, Leak BusterTM MatrWm 322, TOPCOAT®
MB+, TOPCOAT® Fireshield Elastomeric Roofing Membrane, applied at 1 to
1.5 gal./sq.
5. Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane,
EnergyCote®roof coating applied at 1 to 1.5 gal./sq.
6. TOPCOAT® Surface Seal, TOPCOAT® Fireshielde SB Solvent based
Elastomeric Roofing Membrane applied at Ito 1.5 gal./sq
7. Advance Green Technologies Photovoltaic Laminate solar energy collector
auxiliary roof equipment installed in compliance with manufacturer's
specifications and applicable Building Codes.
Maximum Design
Pressure: See Fastening Above
NOA No.: 09-0224.01
MIAMI•DADE COUNTY
Expiration Date: 11/06/13
�9999• • • • Approval Date: 04/08/09
Page 30 of 31
WOOD DECK SYSTEM LpmAnONS:
-1 A slip sheet is required with Ply 4 and Flex Ply'' 6 when used as a mechanically fastened base or anchor
sheet.
2. Minimum '/<" Dens Deck or %2" Type X gypsum board is acceptable to be installed directly over the wood
deck.
GENERAL LIlVITTATIONS:
1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory
for fire -ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product
Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt
applied within the EVT range and at a rate of 2040 lbsJsq., or mechanically attached using the fastening
patter of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt,
panel size shall be 4' x 4' maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam
insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied
using spot mopping with approved asphalt, - 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in
three rows, one at each side lap and one down the center of the sheet allowing a continuous area of
ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed, every 12' in each ribbon
to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbsJsq.
Note: Spot attached systems shall be limited to a maximum design pressure of-45 psE
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F) value of 275
lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-
tested, are below 275 lbf. insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a
minimum fastener resistance value in conjunction with the maximum design value listed within a specific
system. Should the fastener resistance be less than that required, as determined by the Building Official, a
revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or
Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal
resistance value taken from Testing Application Standards TAS' 105 and calculations in compliance with
Roofing Application Standard RAS 117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements -of these areas.
Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with
Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered
Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is
specifically referred within this NOA, General Limitation #9 will not be applicable.)
8. All attachment and sizing of perimeter nailem, metal profile, and/or flashing termination designs shall
conform to Roofing Application Standard RAS I I I and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field,
perimeters, and comers). Neither rational analysis, nor extrapolation shall be permitted for enhanced
fastening at enhanced pressure zones (i.e. perimeters, extended comers and comers). (When this limitation
is specifically referred within this NOA, General Limitation #7 will not be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building.Code
and Rule 9B-72 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
NOA No.: 09-0224.01
CM1AMHMMMDEEC=0LURNMT Expiration Date: 11/06/13
Approval Date: 04/08/09
Page 31 of 31