Loading...
HomeMy WebLinkAboutSUBMITTED PAPERS., RECEIPT #: St. Lucie County Building & Zoning 2300 Virginia Avenue Ft. Pierce, FL 34982-5652 Tel. 772-462-1553 APPLICATION FOR ROOF PERMIT Location/Site Addrt Parcel ID Number: St Office Use Only Section Township Range I Map Page I Zoning Land Use I Initials 103 1 3co 4a 12NO3S I c2 S3 3. Description of Project or Work Activity �08L OPF S hnq1- 1?M-k 4. Total Roof Area (square feet): i'7 O 5. Roof Pitch:`�- 6. Type of Roos': [ ] Fiberglass Shingle [ ] Concrete Roof Tile [ ] Wood Shake / Shingle [ ] Tar & Gravel [ ] Modified Bitumen [ ] Other 5 V cyfmpM AI L [-4'N.O.A. or Florida — Product Approval required for all types of Roofing Material (2 Sets) �� El✓5 [ ] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product Approval attached ** Roof Mitigation per F.S. 553.844 will be required. 7. Owner Information 8. Contractor Infor/m�attinionn Name: 1 FL Reg/Cert #: C l� l �, 3 2,121 U Address: Y County Cert #: 20 1 o s - - City: State: h , Business Name: , ��TAN hr Zip: q % 2 Phone: 9. Value of Construction: $ 1 0 Fees Due: zes, vy0 ^ Receipt #: Note Dry -in and Final Inspection Required Additional inspection may be required per Product Approval CONTRACTOR/OWNER'S AFFIDAVIT: I -certify that all of the informatio o ined in this application is correct and that all work will be done in compliance with all ap icabl laws regulating construction and zoning. PRINT QUALIFIERS/OWNERS NAME SIGNA OF IFIER/OWNER STATE OF FLORIDA, COUNTY OF I ACKNOWLEDGED BEFORE ME THIS Q 0 DAY OF 2010--, BY � �ri'�16 Y WHO I PERS ALLY NO '✓ TO ME OR HAS PRODUCED AS IDENTIFICATION _ NOTAF!' P'.:2 � iC-STATE OF FLORIDA J.SIGNATURE OF NO RY TYPE OR PRINT NAME OF NOTARY <. ;;uigftalS. Nielsen yl ., ..'ommission # DD551441 COMMISSION NU*1BER'qql ` .F' M G:.1. Expires: 06/12/2010 NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RNULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTARY PUBLIC -STATE OF FLORIDA Karen S. Nielsen Commission #DD551441 MY Comm. Expires: 06/12/2010 JOSEPH E. SMITH, CLERK OF THE CIRCUIT COURT - SAINT LUCIE COUNTY FILE # 3431188 OR BOOK 31•' PAGE 2115, Recorded 01/15/2010 at 1C' AM SLC, PrRMrT NUMBER: NOTICE OF COMMENCEMENT The undersigned hereby given notice that improvement will be made to certain real property, and in accordance with Chapter 713. Florida statutes the Following information is provided in the Notice of comment . 7 O I Q tv1 n I. DESCRIPTION OF PROPERTY (Legal description and street address) OL O NUMBER: Q 2 SUBDIVISION BLOCK�TRACT LOT ILY 2BLDG UNIT 2. GENERAL DESCRIPTION OF 3. OWNER INFORMATLONt b.Address' I lh l A31CM\ I:Uyl11tOCt1 r d, Name -and address of fee simple titleholder (if other than 4. CONTRACTOR'S NAME, ADDRE55_ANOLPHONE NI in property [i r t n f• Y 5. SURETY'S NAME, ADDRESS AND PHONE NUMBER AND BOND AMOUNT: 6. LENDER'S NAME, ADDRESS AND PHONE NUMBER: 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13 ([)(a) 7., Florida Statutes: NAME, ADDRESS AND PHONE NUMBER: 8, in addition to himself or herself. Owner designates the following to receive a copy of the Lienor's Notice as provided in Section 713.13 00), Florida Statutes: NAME, ADDRESS AND PHONE NUMBER: 9. Expiration date of notice of commencement (the expiratioNclate is I year from the date of recording unless a different date is specified) _,10_. Signature of Owner or Owner's Authbrized Officer/Director/Partner/Munager .+�- G 10 C S2::22,1-24e�C- Print Name and Provide Slenatory's Title/Office State of FloFloridaa '""�r County or LIU] le 16 I - f The foregoing instrument was acknowledged before me this � 14 day cf xv1n U fir _, 20 f 0 By yeVj P !IDDiPA as 0 ME — (Name of person) tType of authority... e.g. Owner, officer, trustee, attorney in fact) For (Name of party on behalf of whom instrument was executed) Personally Known_ or produced the following type of ID NOTARY PUBLIC -SPATE OF FLORIDA NAKaren S.' Nielsen �9 �fy_r: • 1 (_ le.. 1 Commission #DD551441 (Printed Name of Notary Public) (Sibnature of Notary Public) My Comm. Expires: 06/12/2010 Under penalties of perjury. 1 declare that I have read the foregoing and (hat the facts in it are true to the best of my knuu•ledge and belief tscction 92.525. Florida Statutes1. Signature(s) of Owner(s) or Ow•ner(s)' Authorized 0(ficer0reclor/Partner/1lanager who signed above: By .O — By f l e„ ,uvp,:unaa�umc• STATE OF FLORIDA ST. LUCIE COUNTY THIS IS TO CERTIFYTHATTHIS A TF of By Da 02/04/2010 12:28 17724688397 JA TAYLOR ROOFING PAGE 01/01 Public Works Department Code Compliance Division 2300 Virginia ,Avenue Ft. Pierce, FL 34982-5652 INSPECTION ,AFFIDAVIT RE: Permit # 1Q0,, 0 171 I 0 L licensed as a(• Contract • /Engz>xeer/Arclutect/ (Please print name and circle license type) FS 468 Building Inspector* M General, Building, Residential, or Roofing Contractor or any individupl certified under 468 F.5. to make such an inspection. All affidavits must include photographs of cacti plane o>; tho roof with the permit # or address # clearly shown marked on the deck for each inspection. On or about n 1c) , I did personally inspect the roo (Date & time) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S.) C) r jgatu8c Seal License # STATE OF FLORIDA COUNTY OF Swam, to and subscribed before me this kday of 1/-m"( ^, 20�.& by 1.,. v �y� .�; ifi {� - . Who is personally known} or who has produced as identification. Notary Public, State; tate of Florid Signature of No ` l Commission No.: cm- 9/27/07 .4-x, q&,2- &044 s o` o,. NOTARY Pii UC-STATE OF FLORIDA �< Yaren S. Nielsen Commission # DD551441 My Comm. Expires: 06/12/2010 (Seal) Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-2172 Fax: (772) 462-6443 http://www.stiucieco.org/public works/permifting.htm http://airs.slcfl.vetrol.com/AIRSweb.php BUILDING PERMIT Issued: 01/26/2010 Conf#:724 Permit#: SLC- 1001-0184 Job Location: 715 CORY CAMPBELL RD City: FORT PIERCE Permit Type: Roof Page 1 Job Description: REMOVE EXISTING ROOF COVERINGS AND INSTALL " SOUTH FLORIDA METAL SUPPLY " 26 GA: STEEL 5-V CRIMP 24" PANELS ATTACHED TO PLYWOOD DECK. [ FL# 10490 ] `* STANDARD 30 LB UNDERLAYMENT"ASTMD 226 Subdiv: Hunt's S/D Lot: 11 Block: Parcel: 3403-701-0082-000/6 Setbacks Left: Right: Front: Rear: Zoning: RS-3 Number of Units: 1.00 Floors: 1 Buildings: 1 Square Footage: 0.00 Minimum Floor Elevation: Flood Map: Flood Zone: Elev: Contractor TAYLOR CHAD G J A TAYLOR ROOFING INC (772) 466-4040 302 MELTON DR FT PIERCE, FL 34982 Property Owner GEORGE E TIPPINS (772) 201-3777 715 CORY CAMPBELL RD FORT PIERCE, FL 34982-4023 Property Owner MARY S TIPPINS 715 CORY CAMPBELL RD (772)201-3777 FORT PIERCE, FL 34982-4023 Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code including those for all electric, plumbing, mechanical, roofing and structural work. Further, he/she acknowledges responsibility to comply with all requirements of the 2007 Florida Building Code and the St Lucie County Land Development Code. Issuance of this permit may be appealed to the St Lucie County Board of Adjustment by an aggrieved party by filing a notice of appeal with the St Lucie County Growth Management Director within thirty (30) days of the issuance of this permit in accordance with St Lucie County Land Development Code, Section 11.11.00., Appeals. Building Permits shall expire and become null and void if work authorized by such Building Permit is not commenced, having called for and received a satisfactory inspection, within six (6) months from the date of issuance of the permit, or if the work is not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date of issuance of the Building Permit in accordance with St Lucie County Land Development Code Section 11.05.01 (A)(2). NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. s:553.79(10), F.S. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s:713.135 (1)(a), F.S. Christopher Lestrange Building Official Date I i OFFICE USE ONLY: DATE FILED: 0? -q' / a REVISION FEE: In .0 ST. LUCIE COU BUILDING DI 10 REV CO PL CE REYI DATE PLANS D PERMI ' MUST BE PT ON JOB OR NO INSIDE ON WILL BE M A 1. LOCATION/SITE ADDRESS: 2. 3. 4. FILE COPY r 6 C I - C 194 - ST. LUCIE COUNTY PUBLIC WORKS DE: CODE COMPLIANC: 2300 VIRGINIA A FORT PIERCE, FL (772) 462-15 TION FOR BUILDING PROJECT INFORMATION DETAILED DESCRIPTION OF PROJECT Nw. 11 ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO CONTRACTOR INFORMATION: 99MI KY WSTN M-PH90%li PORES: ST. of FL REG./CERT. # 13 227-20 ST. LUCIE CTY. CERT. #.(� BUSINESS NAME: QUALIFIERS NAME:' ADDRESS: CITY: STATE: PHONE (DAYTIME): rlrl2' L4 p' 4040 OWNER/BUILDER INFORMATION: NAME: ADDRESS: CITY: PHONE /CELL: STATE: FAX: FAX: 5. ARCHITECT/ENGINnEER INFrrORMATION: NAME: (. • • t V O. ADDRESS: CITY: STATE: _ PHONE (DAYTIME): q.(p(a- ��o 3 F. ZIP: i C O'P Y SECTION 1525 HIGH -VELOCITY HURRICANE. ZONES --UNIFORM PERMIT APPLICATION Florida Building Code Edition 2007 High -Velocity Hurricane Zone Uniform Permit Application Form. CONCEALED FASTENERS OR ATTACHMENTS INSTRUCTION PAGE ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING PERMIT APPLICATION FORM ACID ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: a Ma a U ~m� mom W,ZJ 9L a O 3 2E •z � z v Roof System Required Sections of the Permit Application Form i Attachments Required See List Below Low.Slope Application A,B,C { 1,2,3,4,5,6,7 ' Prescriptive BUR-RAS 150 Asphaltic' Shingles , A,B,C 14,5,6,7 A,B,D 1,2,4,5,6,7 Concrete or Clay Tile. �A,B,D,E 1 1,2,3,4,5,6,7 Metal Roofs AA B,D 1,2,3,4,5,6,7 j Wood Shingles and Shakes { A,B,D 1,2,4,5,6,7 Other _ _ As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED: 1. fire Directory Listing Page 2. i From Product Approval: Front Page j Specific System Description . 1{ Specific System Limitations General Limitations Applicable Detail Drawingsf ! Fort St4 _ _ 3. Design Calculations per Chapter 16, or If'Applicable, RAS 127 or RAS• 128 4. ? Other Component of Product Approval 5, 1 Municipal Permit Application ` -I 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation.Documentation he cc . ca CM W � ¢ ® Co cs a a 2 ®.¢c�a cc oc us 0j, eu w�ncau Cn co MM M. ui u.r car z- M iE��M8 VEY E. KOEHNEN anal Engineer PE 32831 205 Elyse Circle Lucie, FL 34952 3222 r (7721489-3035 - f ROOF AF -'a BLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2007 High -Velocity Hurricane Zone'Uniform Permit Application C �)"`tSection-A -(G-eneral-information- � ":#� . r Master Permit No. Process No. Contractor's Name .� • • T�� L o R �� I N (,7 Job Address moo GoB.E`f G.tLrv1P155£LL R p. �:• T, P l-r 1— 3 `'i 48 z ROOF CATEGORY '❑ Low Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tile ❑ Asphaltic Metal Panel/Shingles ❑ Wood Shingles/Shakes Shingles 0 Prescriptive BUR-RAS 150 ROOF TYPE New Roof ❑ Reroofing ❑ Recovering ❑ Repair ❑ Maintenance ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) Total (SF) Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. ME ME ■■■ % Mai entire roof With :. rfrig.shari :nails■■■ diam,jull round head 2- .. ..To trusses 1► M■■■■IF,■M ,F�. Kam. foss alengineer?E•3-9 7205 Elyse Circle SL, ucle, FL 34352-� - Fax (772► dW-30:P;` 2007 FLORIDA.BUILDING CODE COMMENTARY Z-'57 Ttli Lost 'C I YY% ROOF ASS" ~`LIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2007F'Lnim High -Velocity Hurricane Zone Uniform Permit Application COPY --_ Section-D (Steer-S.Ioped-Roof_S_y_steml- . Roof System Manufacturer: Sc�Uzrt I�LoR1�A M�t�+- ScJ��LV t,N L S�GRIN.(' 2�o6i�• Notice of Adcep ta#1de-'Member: . C 3o E3 Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): 1• 2�,8 P2: . r- Maximum Design Pressure (From the Product Approval Specific System): 60.5 1U-7frr4o0Z -7,DP S # I s 3 + Z l0W-'1S �UIT7 PMtz1MV'rg Steep Sloped Roof System Description Deck Type: I513 1 µw 1' wi n>©o 0 Type Underlayment: 3 C' ` f=F I-r RL a SFIAI 'LId7 Gl+,P'S +� o.c. a'r LfevQi Roof Slope: �. a,ou,g GDL Z- a . e- 3 12 Insulation: a Fire Barrier: -tk 14" tip`)L ttS,'�, t2 wao® 6arLCwg L4LL�tiK o• G�t`I`Jh Ridge Ventilation? Fastener Type &,S acing: 5�^t5 �'r,R�V�iS $~ '% i�Lti2lA� Go¢NiCL Adhesive Type: r� Type Cap Sheet: --- Mean Roof Height: ��_ Roof Covering: V Gizlnn n Z'!a�►A Type & Size Drip 314 6, Edge: Hr`i9E9' E. ICON` , uteri Engineer PE 12k 7205 Elyse Cirde ; ftt St. L cke, FL 34952-34212- 46 Fax (772) 489-3035 FLORIDA BUILDING CODE COMMENTARY 15- 59 )Florida Building Code Onlinf( Page I of I I 1131111-2 -. i�Afn+aw,.N: eye a ram° � `:�,y�„�,` US.......... �nn r__.. User Registration Hot Topics Submit Surcharge Slats &facts _Publications FBC Staff BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List C '. P �� q 4 Search Criteria Refine Search Code Version 2007 FL# 10490.6 Application Type ALL Product Manufacturer ALL Category ALL Subcategory ALL Application Status ALL Compliance Method ALL Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL Product Model, Number or Name ALL Product Description ALL jApproved for use in HVHZ ALL Approved for use outside HVHZ ALL i{!Impact Resistant ALL Design Pressure ALL OE ther ALL Results - New South Florida Metal Supply, Inc. Steven M. FL#.: FL10490.6 Urich, PE Model:.6-."5,-V Crimp" . (717) 932-8500 Description: Roof Panel - 26 Gauge Steel, 24" Width, Attached to Plywood Deck w/Optional Rigid Insulation Category: Roofing Subcateqorv: Metal Roofina DCA Administration Department of Community Affairs Florida Building Code online Codes and Standards 2555 Shumard Oak Boulevard Tallahassee, Florida 32399-2100 (850) 487-1824, Fax (850) 414-8436 © 2000-2005 The State of Florida. All rights reserved. Copyright and Disclaimer Product Approval Accepts: ecbbr HARM F- Koh FWMIOnW � 3283a de P-M & Lude, FL 34952-321? Fax (772) 489-3035 http://floridabuiIding.org/pr/pr app lst.aspx 10/15/2009 PY yp. f , u,2 -----CBUCK En ][neerh CBUCK, Inc. Florida Certifica[e ofAwhorization # 8064 Specialty Structural Engineering Installation Method Of South Florida Metal Supply, Inc. "5-V Crimp" Metal Roof Assembly for Florida Product Approval # FL 10490.6 Florida Building Code 2007 Per Rule 9B-72 Method: 1 - D Category: Roofing Sub - Category: Metal Roofing Product: "5- V Crimp " RoofPanel Material: Steel Panel Thickness: 26 Gauge Minimum Panel Dimensions: 24" Maximum (Net Coverage) Support Type: Wood Deck. Prepared for: South Florida Metal Supply, Inc. 2120 SW Pomo Drive Palm City, FL 34990 Prepared by: James L. Buckner, P.E. Florida Professional Engineer # 31242 Florida Evaluation ANE ID: 1916 Project Manager: Stephen Peters eport No. 08-127-5V-24-S6W-IM James L. Buckner, P.E. Date: 02 / 25 / 08 Flor'da P.E # 31242 Contents: 3 -0 �1,93 Installation Method Pages 1 — 5 CBUCK, Inc. 1334 S. Killian Drive, Suite 4, West Palm Beach, Florida 33403� KO' Phone: (561)491-9927 Fax: (561)491-9928 Website: www.ebuckin FnglneerPE 326 7205 %W Chrle p.wt 5t,. Lucie, FL 34952-3212 Fax (772) 489.3035 FL #: FL 10490.6 Date: 02/25/08 Report No.: 08-127-5V-24-S6W-W Page 2 of 5 CBUCK, Inc. Florida Cerlificate ofAulhorizalion # 8064 Specialty Structural Engineering Evaluated Installation Method Attachment Description: Roof Panel Fasteners Type: Hex -Head wood screws with weather -sealed washer Size: #14 x minimum penetration through deck 3/16" Corrosion Resistance: Per FBC Section 1507.4.4 Standard: Per ANSI/ASME B18.6.1•. Installation: METHOD 1: V"1. "5-V Crimp" Roof Panel to Deck ■ Fastener spacing: 16" o.c. (along the length of the panel and within 3" from all ends) ■ Fastener spacing: Nominal pattern of 12" (along each row) (at the top of the major corrugations) `/ 2. "5-V Crimp" Roof Panel to Deck ■ Fastener spacing: 8" o.c. j METHOD 2: (along the length of the panel and within 3" from all ends) ■ Fastener spacing: Nominal pattern of 12" (along each row) (at the top of the major corrugations) Fasteners shall penetrate through deck a minimum of 3/16". Manufacturer's Refer to the manufacturer's installation instructions as a supplemental Installation Instructions: guide for attachment. Evaluation Report: Conditions and Limitations of the Evaluation Report apply. C N T FL #: FL 10490.6 Date: 02/25/08 Report No.: 08-127-5V-24-SM-IM Page 3 of 5 Specialty Structural Engineering Installation Method South Florida Metal Supply, Inc. "5-V Crimp" ( 26 Ga. Steel) Attached to Wood Deck 24" Maximum Net Coverage Panel Profile Nominal 12" o.c. Nominal 12" o.c. Fastener Spacing Across Panel Width #14 Hex -Head Screw with WSW \ Spaced 12" across the Panel Assembly Profile I I 11Lq_ - FL #: FL 10490.6 Date: 02/25/08 Report No.: 08-127-5V-24-S6W-IM Page 4 of 5 ----- ----- - - - - - - - - CBUCK, Inc. Florida Certificate OfAuthorization 4 8064 Specialty Structural Engineering Installation Method South Florida Metal Supply,- Inc. "5-V Crimp" (26 Ga. Steel) Attached to Wood Deck METHOD1: `//For 50.50' PSF Design Pressure Panel Fasteners - #14 Hex Head - 15132" or greater Plywood, or Insulation 3" maximum - Wood plank LE COPY Assembly Isometric View I I r FL th FL 10490.6 Date: 02/25/08 Report No.: 08-127-5V-24-SM-IM Page 5 of Aa &W-LIBUCK -EEAqP_iqv.;e1.Rf Specialty -Structural Engineering CBUCK, Inc. Florida Certificate qfAuthorization # 8064 Installation Method South Florida Metal Supply, Inc. "5-V Crimp" (26 Ga. Steel) Attached to Wood Deck 'METHOD 2:* For 106.75 PSF Design Pressure Panel Fasteners - . #14 Hex Head - 15/32" or greater Plywood, or Insulation 3" maximum - Wood plank 0 PY Assembly Isometric View FF Lt,"