Loading...
HomeMy WebLinkAboutSUBMITTED PAPERS_1OFFICE -USE ONLY: DATE FILED: I ' PLAN REVIEW FEE: RECEIPT NO.: CONCURRENCY FEE: RECEIPT NO.: PERMIT NUMBER: CERT. CAP. NO.: _ ALL INFO MUST BE COMPLETE & FILLED IN TO BE ACCEPTED St. Lucie County Building and Zoning '� pA 2300 Virginia Avenue *OX Ft. Pierce, FL 34982-5652 772-462-1553 C 4y APPLICATION for BUILDING PERMIT CERTIFICATE of CAPACITY/ZONING COMPLIANC PROJECT INFORMATION 6—rw, Till n o +- 1. LOCATION/SITE ADDRESS: g O S QS p r cy Cf. . Fv►f R a rce. FL. 3 9q 4 `9 —7 2. PROJECT NAME: Cl -4 n&C� SITE PLAN NAME: 3. PROPERTY TAX ID #: 1 `1 / US0103430001 4. LEGAL DESCRIPTION (attach extra sheets if necessary): W 313 of +tic O c e a vt Resorts Co- O e " (Jeyelu�v►,ea+� LXj'wq w;4;n RAO- of Se,+iOvk 10+-11 .� Towns►. -Jo 34s °RIDE of SJL l'Lmcie Co. 5. PLAT BOOK 6. PAGE NO. 7. BLOCK NO. 8. LOT NO. 9. PARCEL SIZE (ACRES/SQ FT.): 0 / G O LOT DIMENSIONS: 3 a X, q Z 10. COMPLETE DESCRIPTION OF CONSTRUCTION PROJECT OR WORK ACTIVITY: 11 SETBACKS (ACTUAL) FRONT: 12. TYPE OF CONSTRUCTION (Check all appropriate boxes) SIDE: _� LEFT SIDE: M NEW CONSTRUCTION [ ] EXPANSION/ADDITION [ ] INTERIOR RENOVATION fyj RESIDENTIAL [ ] COMMERCIAL [ ] INDUSTRIAL W OTHER(SPECIFY) New nri France: moelu.)-- /iowte. Qr5L. w�dc- 13. DESCRIPTION OF PROPOSED USE: — S;sn leL rarwil�e Qwe LLQ—Ty l 14. 16. SQ. FT OF CONSTRUCTION: f! 4/q 15. SF. FT 1st FLOOR: 1.1 y Y ' VALUE OF CONSTRUCTION: $Q 4v, The value of construction is used to determine the amount of permit fees to be assessed St Lucie County reserves the right to question and/or mpdify the indicated value of constriction if it is demonstrated that the submitted figures are not consistent with similar types of construction activities. if the value is $2500 or more, a RECORDED Notice of Commencement must be submitted with this application. SLCCDV Form No.: 001-02 SCANNED BY St. Lucie County OWNER INFORMATION NAME: I6 e ADDRESS: 9 0 Iezngk YQv C- . F'owt Pierce. IZI . 3`I`1 CITY: F-yy+ pi evcc- I STATE: 1=1 ZIP: 8 9 y 9 PHONE (DAYTIME): & `{ '3 - �F b 52 Email: IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE, PLEASE FILL IN NAME AND ADDRESS BELOW. FEE SIMPLE TITLEHOLDER -5~-P .pis 4 B oy-P ADDRESS: CITY: STATE: ZIP: PHONE (DAYTIME): �) CONTRACTOR INFORMATION ST. of FL REG.CERT #: 15-�- 32 ST. I,UCIE COUNTY CERT #: c2 BUSINESS NAME: -DCIROC=N 601Y51 thT1OA( vi .-rNG QUALIFIERS NAME: MIKE Du Deb/ ADDRESS: i t S /PEARL S CITY: 8 0 11 RO A Ltd STATE: FL ZIP: 3 3 � �- 3 PHONE (DAYTIME): (?) a. a + - f b'LZ. FAX NO.'9 0 - q (p1- I bSS Email: M I K sZ. d M Z Q 9(,TA1w i L , CQftA. ARCHIT/ENGINEER: In r c-li" L 7o- od I� o ADDRESS: 2 C7 2 O CITY:a�S'� STATE: ZIP: PHONE (DAYTIME): (_) 963 - 687--S'/q5'- oF�c BONDING COMPANY: W 1 L L r AM s l f E55 -ZNSCl RiEN64_ 86 3 - (086 •- 30 ✓ / - EAK ADDRESS: l to U 6, 06-EV R6 4 b 1 !o CITY: STATE: FL ZIP: ,-'9 ]� F-0 1 MORTGAGE LENDER: ADDRESS: CITY: STATE: ZIP: IMPORTANT NOTICE: When a permit is issued and it is not picked up within 60 days after notification it will be voided and returned to you by mail. 0 i s s � St. Lucie County Building A Zoning 2300 Virginia Ave Fort Pierce, FL 34982 BUILDING PERMIT SUB -CONTRACTOR SUMMARY - a fA Dan e��r �ll,�(� I al �V will be using the following sub -contractors for the (Company/IndividW] Name) project locatedat 909 O.s+^tYC'' 4cmh �es�v+ jy 1aS0�p3y3Uoa4 (Street address or Property Tag ID €t) It is understood that if there is any change of status regarding the participation of any of the sub -contractors listed below, I will immediately advise the Building and Zoning Department of St. Lucie County. Trade Name of Company/Contractor A St. Lucie County/ State of Florida License Number Electrical 111-4cdFLU %/2%C 7 C I3O0 ` 2 Plumbing .J U,�:! .. / A l,. E_ 4171 8LUL C F G_0 59 00 e,41.t HVAC/ Mechanical/ ,&oB �� ��©r89 � Roofing jRc� >" r - I L°4p- ONLc,/ / s Gas A/ t )F'ICE Ka"', PERMIT ISSUE.DATE: _ NUMBER: _ E71/17y/1t71d 1J:Ju bb3b444'L/1 LILLEY AC PAGE 03/03 FES-9-2010 01:04P FROM: - ST. LUCM C(11yM PUBLIC vVB .1 DIM.DDTr to 7f1mm'Mi NTAReTM919 MOM"No FROM SUB -CONTRACTOR AGREEMENT ' St. LUM noway w,uea..w, ......1.r..•1--'T-1 M� State of Florida t✓ettifloahon lrlr,uaer W'PP-weer c C �A 1tY1vG taly�.o.l :.. ll1 �� copois m ftdividu Name) (type of Trade) (Primary CoatGcR►r) for the prof ect I ocated at D D5 t°R CT 0d6AN IT65PRis (r»je t S et nd or Property Tax m #) fl o SO Z o 3 3 0 00o q It is understood that, if there is any change of status regarding our Participation with the above mentioned project, I will iMTRediately advise the Building and Zoning Department j C1. Luoie rnonty by itennnAy A1Jf}g P C111LIA66 Of Caetraotor notiCP„ (.Form' St.CCDV No, 004 -00) RIU0241JWOL, mI! LLIKER III & OR i nuuuol r�rmin nn Uu11 illfl(�iiYWP'��: ""� ORIGIMA T, �9TaNATURES Attb: sMt! u r "Ab r .' r I 0 stAKAT R +.r...._ no F Old— city/Stateitlp: Phone: ••ES-9-2010 01'360 FROM: T0:9652745 P.2/2 ST. LUCIE COUNTY PUBLIC WORKS - - - - - --BiTIY+DTNG__&NT _ZONING_DEPARTMF_ RMBINC PERM SUBCONTRACTOR AGIt EMENT i 94 Lucie Cmunty Contractor CertitimU nNumbu: State of 8lorido Ce►tificadonNutaber a[oppuvblo): , u Aim _ q t- ALORON have agreed to be the -Company 1ggMcP1ndivldue1 Name) Subcontractorfor ,s l%�11C1 /ON �!✓G i (Type of de) (Frimaty Coa(Mar) �W •S'mZ1 3 0000 9 i for the project I Ccatod at D 8 Os _ OCEAN! Ar.W QT • . (Proc S t .— or property Tax ID /!) t w pg O Z O 3 it$ t7000 `i k is understood that, if there is any change of status regarding our participation with the above mentioned project,l will immediately advise the Building and Zoning Department of St. Lucie County by persorWly filing a Change of Contractor notice. (Form_ SLCCDV No. 00"0) BUSINESS QUAY• (Name ofthe lndlvldual shown on the Contractor's License) (RIGINAL SIGNATURES ARE REQUIIIBD I-4-t-own WON —ATM pttn+lT NAME DATE BusinessAtama ^v`eA s��-�B• � ''�^, 8, n qrne. Address: _ • o it 2 / fp _ City/8tataip: C �, . ce dW etnaV' SDK Phone: Z0/Z0 39tid 9NIawnld 31d1S Nns SOLZ996£98 L£:9Z 0Z0Z/60/Z0 02/09/2010 13:38 8636444271 FES-9-2010 01:04P FROM: �— LILLEY AC 7'i444271 PAGE 02/03 P.3/3 - - - - - — - -- ST._TIT1t:ff. _CIO UNTY P�TBLIG w4 s- BUILLDIN(.1 A 5EONINC DEPARTMENT 13UMDING PERMrr SUB —CONTRACTOR AGREEMENT St. Lode Coaoly ConOcacW CW f=tiQaNt�Qbes= j/�}� Qn t Vi ugnnFnrmnnun �i�un� nanni� subcontractor for DWAK &YV .G�olt%�'%%i°�! ofTmde) (Pf ely'Coatiptbr) — for tho projoar loomed ut--P L? r�FM-&-f e cPt,�iBudd AddrmnrPrMRryTAT m1) /OJ1tNr4lei J(qe M9 It it mAotm tod that, it tbara is AY uhafip of Status regarding Our'Forti4ipat, UJA wills d,o above mentioned project, I will immcoliately advise the Building and Zoning Department 1 II 111 11 00 1 1. If 1 111111111 No. 004-00) DUEDFUR QU 4LITi ER plJ--u 214ki ]ULCUUU11 BUMS m ohs reawntm'n 1 Innann) ORIGGIVAL SS'WWATURES ARE REQUIRED fr g NAMB UDA Business Nam: 1'. A l ( Addme: 1 Qty/State2ip: Lwkejand Phoae: Zit _,3— to 4 4 - M lei email: nFFr[`F TTCF. AtiT N! rr 0 ISSUE DATE J'L&"r ST. LUCIE COUNTY PUBLIC WORKS BUILDING & ZONING DEPARTMENT BUILDING PERMIT SUB -CONTRACTOR AGREEMENT St. Lucie County Contractor Certification Number: State of Florida Certification Number (If applicable): 1 Lacy have agreed to be the r 'Company Namd/Individual Name) sub -contractor for (Primary Contoc>`or) (Type of Trade) for the project located at P7— /�PIC56- Za3g3000 or Property Tax ID It is understood that, if there is any change of status regarding our participation with the above mentioned project, I will immediately advise the Building and Zoning Department of St. Lucie County by personally filing a Change of Contractor notice. (Form: SLCCDV No. 004-00) BUSINESS QUALIFIER (Name of the Individual shown on the Contractor's License) ORIGINAL SIGNATURES ARE REQUIRED SI NAT PRINT NAME DATE Business Name: T f �/J � (lG7/_O AJ `7 AI -- Address: City/State/Zip: Phone: lb 3 -ate l —1 fo Z2— email: M / K& c,I co" OFFICE USE ONLY: PERMIT # ISSUE DATE a ST. LUCIE COUNTY PUBLIC WORKS BUILDING & ZONING DEPARTMENT - BUILDING PERMIT SUB -CONTRACTOR AGREEMENT St. Lucie County Contractor Certification Number: L� State of Florida Certification Number (If applicable): (2 0 50 60 r Ac (, !, 2�have agreed to be the Company IQamenndiviaii^ame) LB sub -contractor for ���� (Ty o rade) (Primary Contmcror) ro' act located at S l' C� DC�'A� f' 5,OA7_ q/�0 ZO 34�3oco 1 for the p J (Proje t Str et Address or Property Tax ID #) It is understood that, if there is any change of status regarding our participation with the above mentioned project, I will immediately advise the Building and Zoning Department of St. Lucie County by personally filing a Change of Contractor notice. (Form: SLCCDV No. 004-00) BUSINESS QUALIFIER (Name of the Individual shown on the Contractor's License) ORIGINAL SIG ATURES ARE REQUIRED SI19 NA PRINT NAME DATE ns ZV Business Name: �tl/2 ��% IG%/D)li Address: /!S �¢�2L City/State/Zip: 2/1%0 9 L� AL. -:T3 g; ,x 3 _ Phone: 03 -,P,;z I — ! IO 22_ email: ✓h ll""f ci ST. LUCIE COUNTY PUBLIC WORKS BUILDING & ZONING DEPARTMENT BUILDING PERMIT SUB -CONTRACTOR AGREEMENT St. Lucie County Contractor Certification Number: State of Florida Certification Number (if applicable): `� 6 have agreed to be the h 'Company Name�/individual Name) C. .QG` sub -contractor for ,% qR,6 _ �oN ,�N� (Type of Trade) (Primary Cont�c>`or) for the project located at ?06 OS'iRRE:r-/ �U LC€Aa Ps° � *l 4/-a5-ozo3,' 3o,5o 7 1p�A;p .+ ctr et Address or Property Tax ID #) It is understood that, if there is any change of status regarding our participation with the above mentioned project, I will immediately advise the Building and Zoning Department of St. Lucie County by personally filing a Change of Contractor notice. (Form: SLCCDV No. 004-00) BUSINESS QUALIFIER (Name of the Individual shown on the Contractor's License) ORIGINAL SIGNATURES ARE REQUIRED %SSR NATURE PRINT NAME DATE Business Name: Address: p(' y e6 S7 City/State/Zip: AGc!L F" Z. 3 Phone: 102-2- email: 1ked OFFICE USE ONLY. ST. LUCIE COUNTY BUILDING & ZONING 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 __ - 772-462-1553 FILLED LANDS AFFIDAVIT I, the undersigned, am the owner of the following described property: 'Tax l.0. !KI D50203'130do°r SOg O T oxC�t• hurt Pierce. F1c,. (Tax ID/Legal description/Address) 34i Vi `l for which I have applied to St. Lucie County for a Final Development Permit. In accepting this Final Development Permit, BP Number , I acknowledge that as owner of the above described property, and in accordance with Section 7.04.01(D), St. Lucie County' Land Development Code, I shall be responsible for assuring adequate drainage so that the immediate community WILL NOT be adversely affected. I further acknowledge that in granting this permit for the development of this property, St. Lucie County is neither obliged nor liable to provide for, or maintain in any form, adequate drainage off my property which will not adversely affect the immediate community. f3cveyly chcz Ina k Che5AtseK Property Owner Name 1P.r . , . er.Sianature ► a STATE OF FLORIDA, COUNTY OF P6 ACKNOWLEDGED BEFORE EFORE ME THIS � `�— DAY OF 20J—Q, BY X VQ... l� { l� Y\�! _ WHO IS PERSONALLY KNOWN TONE OR WHO HAS PRODUCED -�1 - ��t ' IDENTIFTCATIO . 'rn SIGNATURE OF NO Y TYPE OR PRINT NAME OF NOTARY (SEAL) NOTARY PUBLIC TITLE COMMISSION NUMBER - ' - KIMERLY�WAL MNS ........� ■peee.L,........ .......... a..@.....I... ..1. ICIF49ERLY t%,4TICINS G s 1/7/2011 S:aL; ;,Asp., Inc ��=aeC.i.YLa.cGGac...eC.............. n.na..... ; CERTIFICATION: This application is hereby made to obtain a permit to do the work and installations as indicated, and to obtain a certificate of capacity, if applicable, for the permitted work. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits may be required for ELECTRICAL, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AND AIR CONDITIONERS, FENCES, ETC., not otherwise included with this building permit application. St. Lucie County makes no representation that its granting of a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Homeowner Association rules, bylaws or any covenants that may restrict or prohibit such structure. Please consult with your Homeowner's Association and review your deed for any restrictions which may apply. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures (all types), swimming pools, fences, walls, signs, screen rooms, utility substations & accessory uses to another non- residential use. NOTICE TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR HAPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOBSITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE TO APPLICANT: IF IT IS NOT YOUR RIGHT, TITLE, AND INTEREST THAT IS SUBJECT TO ATTACHMENT: AS A CONDITION OF ISSUANCE OF THIS PERNUT, YOU PROMISE IN GOOD FAITH TO DELIVER A COPY OF THE CONSTRUCTION LIEN LAW NOTICE TO THE PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT. OWNER O TRACTORISIGNATURE STATE OF IDA COUNTY The foregoing instrument was acknowledged before me this day of 20��, by &N _Ar_A A�AErl who is personally l�nown or has produced STATE OF FLORIDA COUNTY OF � rK. The foregoing instrument was acknowledged before me this day of 20L_, by�. who is personally known ✓ or has produced as identification. as identification. Signature of Notary e............................................Signature of Notary ;..............................:.......... KIMBERLY WATKINS MASER' WATKINS e ' Will cm# DD0627403 f- m#DDW27403 n Commission No.0 Q commission No ,._.., NOTE: TWO (2) SIGNATURES ARE REQUIRED. EACH SIGNATURE MUST BE NOTARIZED. IF APPLYING FOR THIS BUILDING PERMIT AS AN OWNER/BUILDER, THE OWNER MUST PERSONALLY APPEAR TO SIGN THIS APPLICATION IN THE OFFICE LISTED ON THE FRONT OF THIS APPLICATION. OWNER BUILDER AFFIDAVIT WILL BE REQUIRED FOR ALL OWNER/BUILDER APPLICANTS. For specific instructions see appropriate permit checklist. A As T- OFFICE USE ONLY BP #: 1-001,0(qP SECTION TOWNSHIP r r RANGE / O MAP NO. 1 / ZONING (L�- LAND USE ---- - - -- - - - - LOT CVG % ---- - -- �) ^ CU TAZ NO. — - --- - — - --- -- FLOOD ZONE FIRM MAP # 1� FLR ELV MAX HGT L CONST TYPE OCCUP TYPE MAX OCCUP # OF FLRS f / WATER SEWER SPRINKLERS STORMWATER LOT OF REC LOT OF REC LOT SPLIT LOT SPLIT Before 1/1990 After 1/1990 REQUIRED APPROVED REPORT HABITABLE RADON PERMIT CODE r AREA FEE FEE i O LIBRARY PUBLIC BLD PUBIC BLD PARKS IMPACT IMPACTFEE IMPACT IMPACT FEE CORRECTION FEE FEE GENERAL SCHOOL ROAD CREDIT Y N LAW ENF IMPACT IMPACT IMPACT FEE FEE FEE FIRE/EMS DRIVEWAY Y N DRIVEWAY ADMINISTRATIVE IMPACT REQUIRED FEE VARIANCE FEE FEE SPECIFY MECHANIC '� ROOF f NON -CONFORMING MISCELLANEOUS SUBS ELECTRIC f GAS LOT OF RECORD FEES REQUIRED PLUMBING �C FEES DATE SENT TO ADDRESSING_ REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE r j 11.27110 RECEIVED / DATE 1,31141161 COMPLETED INIT AIALS JOSEPH E. SMITH, CLERK OF THE CIRCUIT COURT — SAINT LUCIE COUNTY FILE # 3451302 OR D? '\3178 PAGE 2671, Recorded 03/16/201(j" 01:49 PM AF M RECORT)INO.OFn RN TO: PERM NUMM I NOTICE OF COMMENCEMENT The undersigned hereby given notice that improvement will be made to attain teal property, and in accordance with Chapter 713, - - Florida statutes the following information is provided in the Notice of eomDencemenL L. DESCRD'TION OdF� ORERTY (Legal description and street address) TAR FOLIO NUMBER: 1`(10 50 ;t 0 3 4 3 O O O 9 SUBDIVISIONQ� . BLOCK TRACT LOTSy3 ByDB_yGUNIT_ "g 04pre4 CY CCeen Resori•a Cent' cult 393 ( 10:3YS :40EIybos 2. GENERAL DESCRIp'I'IONOFIMPROVEMENT: ae12105S ICKI of did unit' w;44 Ne- pcA Ek e 3. OWNER INFORMATION: a. Name ever) b. Address 909 Q -% VW Ci 17 pke Q..g 4T+ Ck c. interest in property-9 wh t Y d. Name and address of fee simple titleholder (if other than owner) 4. CONTRACTOR'S NAME, ADDRESS AND PHONE NUMBER: 1y11 c h rue C. 4 J r� ee.f C ire, t a �2a 4rztn jA Ave.. ALiht.t--,udalc. FL. 81.3-9(os og83 5. SURETY'S NAME, ADDRESS AND PHONE NUMBER AND BOND AA OUr9T: I— itt 6. LENDER'S NAME, ADDRESS AND PHONE NUMBER: II//44c 7. Persona within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13 (lXa) 7., Florida Statutes: 11o7 3y% NAME, ADDRESS AND PHONE NUMBER: 1t+1. S. In addition to himself or herself, Owner deli the following to receive a cc y of the L' nor's Notice as Provided in Section 713.13(1)ro).�oridaStatutes: P•o J3IgC rp�- ��3 oLse o h Pam• 3� �� NAME, ADDRESS APO PHONE NUMBER: 9. Expiration date of Doticygf ncemem (the expiration date is 1 year from the date of recording unless a different dale is specified) A A !�-� .20_. Print Name and Wovide Signatory's TitldOM- Owner's - avnar State of Florida-� J Countyof -hd►an 1V the foregoing instrument was owledgea btan thin I 15 day of 1a/I ua - N 20 / d Iaclmefore Crype of authority ..e.g. Owner, officer. [idea, attorney in fact) (Name of pers ,g�� For Ie,—IM I., L' esa^&K (Nano of party d6 behalf of whom instrument was ereaaed) Personally Known_ or produced the following type of ID: lEiwEtAi�ERr �LQn i�.ainbGr� v WCOWSSIONsDGt-7"rl (Printed Name of Notary Public) (Si of Notary Public) EXPIRES: October 26.21 8W4WMw"PUbr-Uide*We Under penalties of perjury, I declare that I have read the foregoing and that the facts in it are tote to the est o my knowledge and belief (section 92525. Florida Statutes). Slguu (a) of Owner(p) or Owner(a)' ADth Offimr/D1n etodPartrrer/Manager rho signed above' ` r e By����� •c5an�1C. By: p:t.(# C aSa ova Flo &L' SAA�� of T01 :-A SS tHiS' iAUF By. Do • ST. LUCIE COUNTY PUBLIC WORKS BUILDING & ZONING DEPARTMENT - --- — ------ -- --- BUILDING PERMIT SUB -CONTRACTOR AGREEMENT St. Lucie County Contractor Certification Number: ~� State of Florida Certification Niunber (if applicable): oo 4— LO?QN have agreed to be the ��C� �y� �� sub -contractor for r���'l �� �-� (Type of Trade) (Primary ContEpro) ` / p $ C,Z3 3 0000g . for the project located at or Property Tax ID #) / 5t/ c-;,S O L U 3 1�6 c5000 , It is understood that, if there is any change of status regarding our participation with the above mentioned project, I will immediately advise the Building and Zoning Department of St. Lucie County by personally filing a Change of Contractor notice. (Form: SLCCDV No. 004-00) BUSINESS QUALIFIER (Name ofthe Individual shown on the Contractor's License) ORIGINAL SIGNATURES ARE REQUIRED SIGNATURiE PRINT NAME DATE Business Name: Address: P O SQA� City/State/Zip: Phone:. �/ o �f 6 email: irr TTeIIM d"%WTT 'V L) rit-J& uar. %JI.L1. PERMIT # ' ISSUE DATE email: A. ST. LUCIE COUNTY PUBLIC WORKS _—BUILDING — BUILDING & ZONING DEPARTMENT_ BUILDING PERMIT SUB -CONTRACTOR AGREEMENT St. Lucie County Contractor Certification Number: ��• i 3 0 0 / 9 •� 1 State of Florida Certification Number (if applicable)' have agreed to be the -' sub -contractor for (Typ e of Trade) (Primary"ContMc%r) e 'l C���AN r��SoT�I s for the prof ect located at SIQ �+ NMet Address or property Tax ID #) l If / o SO 2 r/ a zJ 300009 V�lPf It is understood that, if there is any change of status regarding our participation with the above mentioned project, I will immediately advise the Building and Zoning Department of St. Lucie County by personally filing a Change of Contractor notice.. (Form: SLCCDV No. 004-00) BUSINESS QUALIFIER (Name of the Individual shown on the Contractor's License) ORIGINAL SIUNATURES ARE REQUIRED ff-J SI�NARE NAME Business Name: Address: City/State/Zip: Phone: OFFICE USE 4 at r ST. LUCIE COUNTY PUBLIC WORKS - BUILDING_& ZONING DEPARTMENT BUILDING PERMIT SUB -CONTRACTOR AGREEMENT St. Lucie County Contractor CertificationNumber: State of Florida Certification Number of appticable): CA K? 19 `7 -7 6 ` 4 . / z have agreed to be the omr pamd/Itidividual Name) G' sub -contractor for�'�— ype of Trade) (Pnmary'Cont�ciur) for the project located at �0 S C -✓V� (Pr oje t Str et Address or Property Tax W #) 1 `f /6 6" 0 Lo ,3Sf.300009 It is understood that, if there is any change of status regarding our participation with the above mentioned project, I will immediately advise the Building and Zoning Department of St.. Lucie County by personally filing a Change of Contractor notice;, (Form: SLCCDV No. 004-00) BUSINESS QUALIFIER (Name of the Individual shown on the Contractor's License) O INAL SI.NATURES ARE REQUIRED zy 0 1 "elf IGNATU0 �PONT NAME DATE Business Name: LLLc7C C/ __4 (f/7f - -- Address:/lRb City/State/Zip: _ � P�� /U%� /-L 3 3 ,t) 1 Phone:�fV=�% email: FAX_ k(o3- W-4271 OFFICE USE ONLY: PERMIT# ISSUE DATE Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 4624172 Fax: (772) 462-6443 http:/hvww.stiucieco.org/public works/permitting.ht n http://airs.slcfl.vetrol.coFn/AIRSweb.php BUILDING PERMIT Issued: 03/16/2010 Conf #; 613 Permit #: SLC- 1001-0198 Job Location: 808 OSPREY CT 343 City: FORT PIERCE Page 1 Permit Type: Building Residential (SFR) Job Description: REMOVE SINGLE WIDE MOBILE HOME AND INSTALL/ REPLACE WITH A DOUBLE WIDE MODULAR HOME ( CONCRETE PERMIT 1001-0204) 2 BEDROOM 3 BATH 1144 SQ FT Subdiv: Ocean Resorts Cooperative Lot: 343 Block: Parcel: 1410-502-0343-000/9 Setbacks Left: 8.00 Right: 0.00 Front: 10.00 Rear: 5.00 Zoning: HIRD Number of Units: 1.00 Floors: 1 Buildings: 1 Square Footage: 1,144.00 Minimum Floor Elevation: Flood Map: 311G Flood Zone: AE Elev: 7 Contractor MICHAEL DURDEN DURDEN CONSTRUCTION INC (863) 287-7907 115 PEARL ST ST AUBURNDALE, FL 33823 Property Owner BEVERLY CHESANEK (407) 463-4059 808 OSPREY COURT FORT PIERCE, FL 34949 Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code including those for all electric, plumbing, mechanical, roofing and structural work. Further, he/she acknowledges responsibility to comply with all requirements of the 2007 Florida Building Code and the St Lucie County Land Development Code. Issuance of this permit may be appealed to the St Lucie County Board of Adjustment by an aggrieved party by filing a notice of appeal with the St Lucie County Growth Management Director within thirty (30) days of the issuance of this permit in accordance with St Lucie County Land Development Code, Section 11.11.00., Appeals. Building Permits shall expire and become null and void if work authorized by such Building Permit is not commenced, having called for and received a satisfactory inspection, within six (6) months from the date of issuance of the permit, or if the work is not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date of issuance of the Building Permit in accordance with St Lucie County Land Development Code Section 11.05.01 (A)(2). N0710E: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies,`or federal agencies. s:553.79(10), F.S. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s:713.135 (1)(a), F.S. Christopher Lestrange Building Official Date 03111/2010 22:11 4622885 PAGE 03104 -. FORM I IODA-08 r LORIDA•ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Performance Method A PMe Wsme: Beverly Chwnwmk. &Mder Norm. StreeC Boo Osprey C L Permit Office. St. Lucie County CRY, Sfafs, Zip: FL Fleroe . FL, Pena$ Number:. .. Owner. arty Cheganek ,furistlidlors: .., .., D"go Losvltlon: FL, Fart Rreme 1 1. New construction or eft" New (From•Plsna) 9. Wah irypes % htsutstlon Ame 2. Single fasnV or multiple firmly Single-family a. Francs - Wood. Extedw R=19.0 1180.80 f m 3. Number of units, k muttlpte ft#nity 1 b. N1A R= its 4, Nurnber of aedmoms 2 c. NJA d. NIA R- fi+ R: 1r 8. Is this a VAX$t one? Yes Im Ceiling Tjnm Insulation Area 6.. Candi i4tled floor arms (1N) 1131. a. Under Attu (UentsM R!30.0 1131.012ff 7. Wfndms 13esaiptlan Ates b. WA li= R= a. It-Fackm ©bl, URD.35 216.50 fP a N!A R= fig SWZ: S"e".w 11. Buts b. "actor: fWA ft a. 6W. Interior Rat Interior AN: E*wior Sup. R.6, 22e 2 fts SHGC: 12, Coaling systems r~ ado. WA ft' a. Central Unit Cam: 22.8 kBtArlhr SNGC: SEER: 13 d. I Wadar. NA 6 SHOC: 13. Nesting systems e. ti-Fador. WA IF A. Electric Heat POV Crap: 17.0 kBtufir SHOO! H�:7.T 8. Fkror guf-0 Area 14. Hot water sysWns a_ fiaiged Floor aZ2.113t.f701t° R a EleMr. Cep: 30 gallons b. NIA R= e a NIA R= it= b. Conservation feahnes W. 0.99 None 1s. cmct 9 C.F. Pstat Glasslftoor Area: 0.191 Tf i As-Buiit Modified Loads: 25.95 PASS fatal Baseline Loads: 34.18 I hereby certify that the plans, Kr1Ve=&WWUUWjM"WV%,01red by this Calculation ate in cf�rnplience vviw the F Energy Review of the plans and' rids fie• spfacificationt3 covered try this indigtses Off, Calculation compliance a > `$ vAh the Florida > Code. PREPARED t31BY-,�1971f►a 7.1Q . Before construction iicompleted DATE: this building will be trued for K�7 Compbrm with Section S3,W8 I hereby Certify that this tnnfdsng, aftdesign , ' in Cv lance Florida Statutes. shay Code.Z'p�,.,� OWNERIAG BUILDING OFFICIAL, DATE: FILE COPY "01a -1-M "A Erl"=GR,MR& UM - F r ,101VA Pa4R 1 Of is 03/11/2010 22:11 4622885 1 f PAGE 04/04 i ENERGY PERFORMANCE LEVEL (EPL) DMPLA czgT111k a,TFr) �NFRGY PERFORMANCE INDEX* = 7S.. The lower the EnergyPerformance Index, the more_ef8cient vie home. I ' New construction or erasting Single family or m lliple family Number of unb. if mud" forrtgy Number of Sedr'ooms Is this a worst cage? Cwrdflioner# floor area On V1Iltrdows" ---. Resaiabtoe i a. LI-Factar. W U=0.35 i SHM.- SHGCx0.30 ! b. U-Factor NIA SHGC: i o. U-Factor: N/A " SHGC: d. U-Faclar N/A SHGC: 1 0. U-Factor. WA SHGC: Floor Types a. Raised Fkjor b. WA M WA i ...., Osprey V� f . 1. 1 .c['./et I {r, Now (From Plans) 9. Wan TYM , Insulaffon Area Sing"moy a. Frame - Wood. Cidedor - R=19.d 1180.a0 fip 1 b. WA :. rR= f12 2 �. NIA n= d. N/A R= fe Yes 10. CeHing Types Insulation Aran 1131 a. Ur4w Afd4 (Vented) R=30.0 1131.Oo JP Ana b. WA W 215.50 fte m WA 11. DUM IV 2. Sup: Interior Retw Interior AH: Exterior Sup. R= 6, 22&2 fP 12. Cooling sydems fr a. Centel unit Cep: 22-6 k6tulhr 11F SEER:13 13. Heating system fe a. Electft Heat Pump Cap.,11.0 kBt ffir WSW: 7.7 Insukft Area 14. HotwaWrvyiftms Ra22.0 1131.00 ft2 a. Eler Cap: 30 gallons R= Rm IF b. Corrservgtion fleatures EF:0.99 fts Now 16. C►edit CF. Patat y that this home has complied with the Florida Energy Efficiency Code for Building ruction through the above energy sav*ffA features which will be instailed (or exceeded) home before final inspecction. Othe , a new EPL Display Card wig be completed e tint l Code comeliaitt elder Signature: (dress of New Home: *Note: The home's estimated Energy Perfomlarim Index is only available through the EnergyGauge USA - ElaRes2()06 computer program. This is not a Building Energy Rating. If your index is below 100, your home may qualify for incentives if you obtain a Florida Energy Gauge R2tting. Contact the Energy Gauge Hotline at (321) 838-1492 or see the Energy Gauge web site at energygauge.com for information and a list of of � d Rater-9- For Information about Florida's Energy Efficiency Code for Buiidina ^cn3 :c or.. Co�TtB�t.he Department of C+bmmuRl[y Affairs at (850) 48 (-1824. ""Label required by Sector. 13-104.4.5 of the Flonda Building Code, Building, or Section 82.1.1 of Appendix G nr t.5r_ rlpr- f."' wding .'�'._n_.L! ,-,-'�i,.�51.7'eCt4 • r.FAUL r .l.11, IT ..^.7. D!Z P11r L 1. Data: CitylFL Zip: EnergyGau" USA - FlaRea2008 FORM 1100A-08 TLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Performance Method A Project Name: Beverly Chesnanek Builder Name: Street: 808 Osprey Ct. Permit Office: St. Lucie County City, State, Zip: Ft. Pierce, FL, Permit Number. Owner: Beverly Chesanek Jurisdiction: Design Location: FL, Fort Pierce 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Frame - Wood, Exterior R=19.0 1180.80 ft2 3. Number of units, if multiple family 1 b. N/A R= ft2c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 5. Is this a worst case? Yes 10. Ceiling Types Insulation Area 6. Conditioned floor area (ft2) 1131 a. Under Attic (Vented) R=30.0 1131.00 ft2 7. Windows Description Area b. N/A c. N/A R= ft2 R= ft2 a. U-Factor. Dbl, U=0.35 216.50 ft2 SHGC: SHGC=0.30 11. Ducts b. U-Factor. NIA ft2 a. Sup: Interior Ret: Interior AH: Exterior Sup_ R= 6, 226.2 ft2 SHGC: 12. Cooling systems c. U-Factor. N/A ft2 a. Central Unit Cap: 22.6 kBtu/hr SHGC: SEER: 13 d. U-Factor. N/A ft2 13. Heating systems SHGC: a. Electric Heat Pump Cap: 17.0 kBtu/hr e. U-Factor. N/A ft2 HSPF:7.7 SHGC: 14. Hot water systems 8_ Floor Types Insulation Area a. Electric a. Cap: 30 gallons a. Raised Floor R=22.0 1131.00 ft2 0.ns 99 b. NIA R= ft2 b. Conservation features c. N/A R= ft2 None 15. Credits CF, Pstat Glass/Floor Area: 0.191 Total As -Built Modified Loads: 25.95 PASS otal Baseline Loads: 34.18 �7 I hereby certify that the plansgnspe ratio covered by Review of the plans andoTKE Sthis calculation are in compliawith the FI rida Energy specifications covered by this V e Code. calculation indicates compliance c� �j�+Pri„ '� 4 with the Florida Energy Code. PREPARED BY: AI17Isnf70Am=&24 "L�c� �— Before construction is completed r - DATE: q 1/e /I o this building will be inspected for compliance with Section 553.908 } I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. COD WE OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: I •� � �- v f a 3 3/10/2090 7:09 PM EnemvGaua -0 USA - FlaRes2n0A Paae 1 of 5 f r , P ENERGY PERFORMANCE LEV"' "''L- 9=q-rIMATF11 ENERGY PERFORMANCE !NDFX* = 763 The lower the EnergyPerformance index, the more efficient the home. 1. New construe-tinn nr gyisfiri� New =rnm Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Frame - Wood, Exterior R=19.0 1180.80 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 5. Is this a worst case? Yes 10. Ceiling Types Insulation Area 6. Conditioned floor area (ft2) 1131 a. Under Attic (Vented) R=30.0 1131.00 ft2 b. N/A R= ft2 7. Windows" Description Area c. N/A R= ft2 a. U-Factor: Dbl, U=0.35 216.50 ft2 SHGC: SHGC=0.30 11. Ducts b. U-Factor: N/A ft2 a. Sup: Interior Ret: Interior AH: Exterior Sup. R= 6, 226.2 ft2 SHGC: 12. Cooling systems c. U-Factor. N/A ft2 a. Central Unit Cap: 22.6 kBtu/hr s SHGC: SEER:13 d. U-Factor: N/A ft2 13. Heating systems SHGC: a. Electric Heat Pump Cap: 17.0 kBtu/hr e. U-Factor: NIA ft2 HSPF:7.7 SHGC: 14. Hot water systems 8. Floor Types Insulation Area a. Electric a. Cap: 30 g lons gallons a. Raised Floor R=22.0 1131.00 ft2 0.99 b. N/A R= ft2 b. Conservation features c. N/A R= ft2 None 15. Credits CF, Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: *Note: The home's estimated Energy Performance Index is only available through the EnergyGauge USA - FlaRes2008 computer program. This is not a Building Energy Rating. If your Index is below 100., your home may qualify for incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at (321) 638-1492 or see the Energy Gauge web site at energygauge.corn for inforimiation and a list Of c :t ied Raters. For information about Florida's Enerciv Efficiencv Code for LJuiluinLa- CorisTucion� co„tact 4-1- 4- Department or Community Affairs at (850) 48 7-1824. "Label required by Section 13-104.4.5 of the Florida Building Code, Building, or Section B2.1.1 of Appendix G EnergyGauge® USA - FlaRes2008 PROJECT Title: Beverly Chesnanek Bedrooms: 2 Adress Type: Street Address Building Type: FLAsBuiil Conditiuned Area: 1131 Lui # ' .Owner. Beverly Chesanek Total Stories: 1 SubDivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: Rotate Angle: 90 Street: 808 Osprey CL Permit Office: St. Lucie County Cross Ventilation: County: St. Lucie Jurisdiction: Whole House Fan: City, State, Zip: Ft. Pierce , Family Type: Single-family FL, New/Existing: New (From Plans) Comment: =iv&A T E V D.esigin Locatiorr T10 Y Site IECC Design Temp Zone 97.5 % 2.5 % Int Design Temp Winter Summer Heating Design Daily Temp Degree Days Moisture Range i �n i3Q ➢ea gi V # riour Type R-Value Ai ua iiiv VVVUu Gaipul 1 Raised Floor 1131 ft2 22 0 C. ROOF / v # 1 ype Materials Roof Gable Roof Area Area Color Solar Absor. Tested Deck Insui. Pitch 1. Hip Composition shingles 1225 ft2 0 ft2 Medium 0.96 No 0 22.6 deg ATTIC 9 V 99 # Type Ventilation Vent Ratio (1 in) Area IRBS IRCC i Full attic Vented 300 113 1 112 A_' �' _ CEILING # Ceiling Type R Value Area Framing Frac Truss Type 1 Under Attic (Vented) 30 1131 ft2 0.11 Wood p WAI I R Cavity Sheathing Framing Solar # Ornt Adjacent To 1Na11 Type R-Val Area R-N/aline Fraction Absor. e I N Exterior Frame -Wood "i 9 414.4 ft2 0.23 U.75 e 2 E Exterior Frame - Wood 19 176 ft2 0.23 0.75 S Exterior Frame - Wood 19 4-14.4 ft2 0.23 0.75 4 IV Fxterinr Frame - Wood 19 176 ft2 0.23 0.75 DOORS Omt Door Type Storms U-Value Area 1 N Wood None 0.460000 21 ft2 WINDOWS &^, ±wn is the entered orientation (=>) changed to Worst Case. Overhang Ornt Frame Panes NFRC U-Factor SHGC Storms Area Depth Separation Int Shade Screening 2 N=>E Metal Double (Tinted) Yes 0.35 0.3 N 5 ft2 3 It 0 in 0 ft 0 in HERS 2006 None 3 N=>E Metal Double (Tinted) Yes 0.35 0.3 N 25 ft2 0 It 0 in 0 ft 0 in HERS 2006 None ■ 4 E=>S kifietal Double !Tinted) Yes 0.35 0.3, N 25 1T2 offoin tiff ni" RPPIC ? A 5 E=>S Metal Double (Tinted) Yes 0.35 0.3 N 36 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 6 S=>W Metal Double (Tinted) Yes 0.35 0.3 N 10.5 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 7 S=>W Metal Double (Tinted) Yes 0.35 0.3 N 15 ft2 1 ft0in 0ft0in HERS 2006 None 8 VV=>N Metal Double (Tinted) Yes 0.35 0.3 N 10 ft' I It 0 in 0 ft 0 in HERS 2006 None ^n-blc (Tinted) Yes 0.35 0.3 N 15 ft2 1 ft 0 in 0ft0in HERS 2006 None 10 W=>N Metal Double (Tinted) Yes 0.35 0.3 N 12.5 ft2 1 It 0 in 0 ft 0 in HERS 2006 None — Forced Ventilation Run Ti— Fan -- — V. �u Z�lu EqLA Supply CF-IVi Li-W- Fraction Default 0.00036 1068 7.08 58.6 110.3 0 cfm 0 cfm 0 0 COOLING SYSTEM V # System Type Subtype Efficiency Capacity Air Flow SHR Ducts 1 Central Unit None SEER: 13 22.6 kBtulhr 678 cfm 0.75 Sys#' HEATING SYSTEM V # System Type Subtype Efficiency Capacity Ducts 1 Electric Heat Pump None HSPF: 7.7 17 kBtu/hr Sys01 HOT WATER SYSTEM 7" # System Type EF Cap Use SetPnt Conservation I Electric 0.99 30 gal 50 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF DUCTS — Supply — — Return — Air Percent # Location R-Value Area Location Area Leakage Type Handler CFM 25 Leakage ON RLF ' 1 Interior 6 226.2 ft Interior 56.55 ft Default Leakage Exterior (Default) (Default) % TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan Heatin Feb Jan Feb [[XX]] Mar [X) MarX Apr Apr IX May May [[XX]] Jun [Xj Jun Jul Jul M Au Au] r 5e SeP Oct X Oct Nov Nov rXr Dec fj Dec Ventin Jan Feb [[XX]] Mar [[�X]] A r [[�X]] Ma [[XX]] Jun Jul Aug ] Se Oct Nov [[XJJ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 FORM 1100A-08 Code Compliance Cheklist Residential Whole Building Performance Method A - Details ADDRESS: 808 Osprey Ct. PERMIT #: Ft. Pierce, FL; INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors N1106.AB.1.1 Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area. Exterior & Adjacent Walls N1106.AB.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from, and is sealed to, the foundation to the top plate. Floors N1106.AB.1.2.2 Penetrations/openings > 1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings N1106.AB.1.2.3 Between walls & ceilings; penetrations of ceiling plane to top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures N1106.AB.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC with < 2.0 cfm from conditioned space, tested. Multi -story Houses N1106.AB.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts N1106.AB.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters N1112.AB.3 Comply with efficiency requirements in Table N112.ABC.3. Switch or clearly marked circuit breaker (electric) or cutoff (gas) must be provided. External or built-in heat trap required. Swimming Pools & Spas N1112.AB.2.3 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. Heat pump pool heaters shall have a minimum COP of 4.0. Shower heads N1112.AB.2.4 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems N1110.AB All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated and installed in accordance with the criteria of Section N1110.AB. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls N1107.AB.2 Separate readily accessible manual or automatic thermostat for each system. Insulation N1104.AB.1 Ceilings -Min. R-19. Common walls -frame R-11 or CBS R-3 both N1102.13.1.1 sides. Common ceiling & floors R-11. S• e n ,r .y .. ' �... .....:v ..: ...v.: .-.. :ter.., ...:>. - • -.-. ..�e_.. .a. .-,, �_. -.r �. :.r.. ,.,i.... .. :..� _.. r. ....a ., .ti.. .. r... ... -.. ....�-ia r - r.t r..... ,.: _ .. ..� .-r.. .... � .. r .t .s . .. -. -. r v.- .. ..err, r.• - l Beverly Chesanek H/AC Load Calculations for Beverly Chesanek 808 Osprey Ct. Fort Pierce, Florida Rimsi iLm11I"T' A ., Prepared By: Residential Energy CaWs Wednesday, March 10, 2010 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. RortSaint_L-uciehvac Residential:& L:oght Commercial HUAC Loads Elrte Software: Degelopment, Inc:,: Ken`Numphrey `� °` . Beverly Ghesanek P Project Report General Project Information Project Title: Beverly Chesanek Designed By: Jacobsen Homes Project Date: Wednesday, March 10, 2010 Client Name: Beverly Chesanek Client Address: 808 Osprey Ct. Client City: Fort Pierce, Florida Company Name: Residential Energy Calc's _ 9 Reference City: Fort Pierce, Florida Building Orientation: Front door faces North Daily Temperature Range: Medium Latitude: 27 Degrees Elevation: 25 ft. Altitude Factor: 0.999 Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Re1.Hum Dry Bulb Difference Winter: 42 39.4 80% n/a 70 n/a Summer: 90 78 59% 50% 75 61 Total Building Supply CFM: 570 CFM Per Square ft.: 0.504 Square ft. of Room Area: 1,131 Square ft. Per Ton: 781 Volume (ft3) of Cond. Space: 9,046 Buildingloads Total Heating Required Including Ventilation Air: 13,604 Btuh 13.604 MBH Total Sensible Gain: 13,030 Btuh 78 % Total Latent Gain: 3,740 Btuh 22 % Total Cooling Required Including Ventilation Air: 16,769 Btuh 1.40 Tons (Based On Sensible + Latent) 1.45 Tons (Based On 75% Sensible Capacity) Rhvac is an ACCA approved Manual J and Manual D computer program_ Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. Rhvac Residential;& Light GommePc�al HVAC toads".Mite Software Development, KeriHumphrey = Beverly Chesanek P,ofi.SamtLucie FL:.34983 Miscellaneous Report yEquivalent_ rquest Qr Outdoor Outdoor ;k outdoor Indoor f" Indoof Grainy nut Date Dry, ,.,>. Wet Bulb: ' Ret.Hum ,. ` Rel:Hum - ;Lary t3uib f Qifference Winter: 42 39.4 80% n/a 70 n/a Summer: 90 78 59% 50% 75 61.09 P0ct-Sizing Inputs m Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wgJ100 ft. Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. I.Outsid Data n Winter Summer Infiltration Specified: 0.310 AC/hr 0.160 AC/hr 47 CFM 24 CFM Infiltration Actual: 0.310 AC/hr 0.160 AC/hr Above Grade Volume: X 9,046 Cu.ft. X 9,046 Cu.ft. 2,804 Cu.ft./hr 1,447 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 47 CFM 24 CFM Total Building Ventilation: 30 CFM 30 CFM —System 1— Infiltration & Ventilation Sensible Gain Multiplier: 16.49 = (1.10 X 0.999 X 15.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 41.50 = (0.68 X 0.999 X,61.09 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 30.77 = (1.10 X 0.999 X 28.00 Winter Temp. Difference) Winter Infiltration Specified: 0.310 AC/hr (47 CFM), Construction: Semi -Tight Summer Infiltration Specified: 0.160 AC/hr (24 CFM), Construction: Semi -Tight Duct Load Factor-Sceriarios for Systam.1 Attic [No`_ DUCt Dudt 9 Surfacer Frorri , . T e. escfi lion L ocatiori , " ` Ceiiir ,Leaks a t, lnsulatior , ` " Area ,; MDD' 1 Supply Main Attic 16B 0.12 6 310 No 1 Return Main Attic 16B 0.24 6 57 No rc"T rtesraeenrara ugm Jul nvH10 Lo3p5 CIIEe.701EWafB VeV810E1(Iletlt, IpC.; Keri Humphrey ' Beverly Chesanek' P"t Sant Luae: FC 34983 _. _ '= Pan6 a`. Load Preview deport Scope Net, Ton! ft' i /Toni ` Area; Seni Gain{ Lath Gains Nets Gain § Sen { ' Htg[ Clgl "''' Act; Duc1 Size CFMi CFM± CFMs --- Building 1.78: 637• 1,131 16,074i 5,234= 21,08: 13,853 168; 709ly 709.J . S tem. 1 ._ ...._.. — — 1.78 637 - _. 1,131: --__ 16,074 5,234 21 308 _ 13,853: .. 168 709 10x14 Ventilation __...... _ ..... . ....__ _. _.....__. _..- _ _.. . 495` 1,245 : 1,740 923; ... Duct Latent _ _...._ _ 1,089 _.._ 1,089` ....... _. --- Zone 1 - ....... - - - -- 1,131 ; - - -- 15,579. 2,900: 18,479: - -- 12,929: - -- - 168. 709: 10xt4 1-Living - .... ............ - . .. ........ _ .............._. -................. _ _ 194. 2,831 594'• 3,425 2,494.32; 129' 1--7 2-Foyer _.....__..------- --.._._....__........... _ - -------..._.. - .__.. 59; ---- . 557 -- 37. 594 804; 10' 25 1--4 3-Bath 1 ------ ------ 90 ------------------.-.--.:..- 919 359: 1,278; -- 838' -- -' 11 42 1--4 _ .... _._ -- 48ath 2 _ .. ........ ...... ...__.. ,. - _ - .81 480 50 530 752 10, 22 1 4 5-Bath 3 135, 1,172 158 1 330 1,588. 21 53 1 4 ._ _ . 6-Bedroom 1 - ._. ....._ .. _ _ - .._ . --- __ .. .._ .._ ._ 196; _.._.. _. 2,496 - - 596: - 3092 2188 28.114 1 6 7-Bedroom 2 _...-_.._..._.-. -_ 140 - 1 345 486; 1,831 1 207 16 61 1-q 8-Kitchen _..-........... ...._...........................:..._....... 7150 2,300 92 2,392 1,222.; 16 105 1--6 9-Dining 86• _. ._.__ 3,481 528; _........... 4,009 1,838. .. ._..... 24'- ......... 158 1_8 lite 'Duct Size Preview �i Maximum! Rough. Design! Summary '----------- ------- ------------- ----- __---_-............. -'__--'.......... ... ....... '___................... ... ... ....... -_-___............ _............... _�__-----_----- _- Heafin Flow: 188 nQ-__-__-__-_'----__-___--_--_-_'-__--__-__----------'--'---------'------'------- Cnn|in Flow. 700 [RhvqC,__-,Residential Light Commercial HUP.G Loads Ehte SoftNtare Deveioptnent, Inc Ken Humphrey _ _ Beverly Chesanek Port'Saint Lucie, FL, 34983 Total Building Suininary Loads Component Area [Description Sen. Lat _ Sett Totai - _- _ : - Quan . Loss Gaut ,, .; -.-,Gain Gam:; 1 D-cb-o: Glazing -Double pane, operable window, clear, 138 1,356 0 2,771 2,771 metal frame with break, u value 0.35, SHGC 0.3 1 D-cm-o: Glazing -Double pane, operable window, clear, 65 638 0 1,926 1,926 metal frame no break, u-value 0.35, SHGC 0.3 11 D: Door -Wood - Solid Core 21 229 0 213 213 12E-Osw: Wall -Frame, R-19 insulation in 2 x 6 stud cavity, 954.4 1,817 0 1,128 1,128 no board insulation, siding finish, wood studs 16C-30: Roof/Ceiling-Under Attic with Insulation on Attic 1130.8 1,012 0 1,447 1,447 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, White or Light Color Shingles, Any Wood Shake, Light Metal, Tar and Gravel or Membrane, R-30 insulation 20P-21: Floor -Over open crawl space or garage, Passive, 1130.8 1,489 0 531 531 R-21 blanket insulation, any cover --- ---------- ----- ._.--------- -------- _ -- ----- _ _-._. . Subtotals for structure: 6,541 0 8,016 8,016 People: 8 1,600 1,840 3,440 Equipment: 300 1,500 1,800 Lighting: 0 0 0 Ductwork: 4,950 1,089 3,825 4,914 Infiltration: Winter CFM: 47, Summer CFM: 24 1,438 1,000 398 1,398 Ventilation: Winter CFM: 30, Summer CFM: 30 . _ ... _ ...... ....._......._.. Total Building Load Totals: 13,853 5,234 16,074 21,308 Check.Figures . -. - Total Building Supply CFM: 709 CFM Per Square ft.: 0.627 Square ft. of Room Area: 1,131 Square ft. Per Toss: 633 Volume (ft) of Cond. Space: 9,046 Building Loads Total Heating Required Including Ventilation Air: 13,853 Btuh 13.853 MBH Total Sensible Gain: 16,074 Btuh 75 % Total Latent Gain: 5,234 Btuh 25 % Total Cooling Required Including Ventilation Air: 21,308 Btuh 1.78 Tons (Based On Sensible + Latent) 1.79 Tons (Based On 75% Sensible Capacity) Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. Residential &Light Commercial HVAC Loads Keri Humphrey _ EUte Software Development, Inc $everfy Ghesanek .J-Rhvac F o64 _Saint -Lucie FL 3498 i [System. I Coleman Or Equivalent Summary Loads . Component Area -Sen Lat Sen Total Desc;d bort ;, Quan Loss -Gain Gain. _. Gain,' 1 D-cb-o: Glazing -Double pane, operable window, clear, 138 1,356 0 2,771 2,771 metal frame with break, u value 0.35, SHGC 0.3 1 D-cm-o: Glazing -Double pane, operable window, clear, 65 638 0 1,926 1,926 metal frame no break, u-value 0.35, SHGC 0.3 11 D: Door -Wood - Solid Core 21 229 0 213 213 12E-Osw: Wall -Frame, R-19 insulation in 2 x 6 stud cavity, 954.4 1,817 0 1,128 1,128 no board insulation, siding finish, wood studs 16C-30: Roof/Ceiling-Under Attic with Insulation on Attic 1130.8 1,012 0 1,447 1,447 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, White or Light Color Shingles, Any Wood Shake, Light Metal, Tar and Gravel or Membrane, R-30 insulation 20P-21: Floor -Over open crawl space or garage, Passive, 1130.8 1,489 0 531 531 R-21 blanket insulation, any cover Subtotals for structure: 6,541 0 8,016 8,016 People: 8 1,600 1,840 3,440 Equipment: 300 1,500 1,800 Lighting: 0 0 0 Ductwork: 4,950 1,089 3,825 4,914 Infiltration: Winter CFM: 47, Summer CFM: 24 1,438 1,000 398 1,398 Ventilation: Winter CFM: 30, Summer CFM: 30 . ....... ...... .. _........ _ ._.... -. _. 923 1,245 _.._. _ .. �....... ..-- -.._.. _.. 495 1,740 .. System 1 Coleman Or Equivalent Load Totals: 13,853 5,234 16,074 21,308 Check Supply CFM: 709 CFM Per Square ft.: 0.627 Square ft. of Room Area: 1,131 Square it. Per Ton: 633 Volume (ft) of Cond. Space: 9,046 System Loads - Total Heating Required Including Ventilation Air: 13,853 Btuh 13.853 MBH Total Sensible Gain: 16,074 Btuh 75 % Total Latent Gain: 5,234 Btuh 25 % Total Cooling Required Including Ventilation Air: 21,308 Btuh 1.78 Tons (Based On Sensible + Latent) 1.79 Tons (Based On 75% Sensible Capacity) ' Notes . Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. . All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. Rhvac Residential Light -Commercial HVAC Loads Ehte Software Development, Inc Ken,Humphrey Y CtiP n eeve ek Port'Saint Lucie FL,34983..' w a e=8 System ;,'Zone 9 Surrimary Loads (Average Load"Procedore for Rooms) Component - . Area : Sen Lat'". ;. -Sen , Total Description : _. ; " - . ;- ,._ . ;Quan T Gain ; _ r: ---Gain , . w.; Gain :l 1 D-cb-o: Glazing -Double pane, operable window, clear, 138 1,356 0 2,771 2,771 metal frame with break, u-value 0.35, SHGC 0.3 1D-cm-o: Glazing -Double pane, operable window, clear, 65 638 0 1,926 1,926 metal frame no break, u-value 0.35, SHGC 0.3 11 D: Door -Wood - Solid Core 21 229 0 213 213 12E-0sw: Wall -Frame, R-19 insulation in 2 x 6 stud cavity, 954.4 1,817 0 1,128 1,128 no board insulation, siding finish, wood studs 16C-30: Roof/Ceiling-Under Attic with Insulation on Attic 1130.8 1,012 0 1,447 1,447 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, White or Light Color Shingles, Any Wood Shake, Light Metal, Tar and Gravel or Membrane, R-30 insulation 20P-21: Floor -Over open crawl space or garage, Passive, 1130.8 1,489 0 531 531 R-21 blanket insulation, any cover Subtotals for structure: 6,541 0 8,016 8,016 People: 8 1,600 1,840 3,440 Equipment: 300 1,500 1,800 Lighting: 0 0 0 Ductwork: 4,950 0 3,825 3,825 Infiltration: Winter CFM: 47, Summer CFM: 24 1,438 1,000 398 1,398 System 1, Zone 1 Load Totals: 12,929 2,900 15,579 18,479 Clieck Figures_.­� ,..,: �. Supply CFM: 709 CFM Per Square ft.: 0.627 Square ft. of Room Area: 1,131 Square ft. Per Ton: 732 Volume (ft?) of Cond. Space: 9,046 Zorie: Loads I . Total Heating Required: 12,929 Btuh 12.929 MBH Total Sensible Gain: 15,579 Stuh 84 % Total Latent Gain: 2,900 Btuh 16 % Total Cooling Required: 18,479 Btuh 1.54 Tons (Based On Sensible + Latent) 1.55 Tons (Based On 75% Sensible Capacity) Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. Rhvac Residential & Li9ht Gomm_ ercial HVAC Loads Elite Software Development, Inc. Humphrey everly Ghe Bsanek. ..Ken Port Saint Lucie, FL 34983 '_ Pa e:9 Detailed Room Loads-- Room 1=-Living (Average Load Procedure) General 771 Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 17.6 ft. System Number: 1 Room Width: 11.0 ft. Zone Number: 1 Area: 194.0 sq.ft. Supply Air: 129 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 5.0 AC/hr Volume: 1,549.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 6 CFM Runout Air: 129 CFM Percent of Supply.: 4 % Runout Duct Size: 7 in. Actual Summer Vent.: 5 CFM Runout Air Velocity: 482 ft./min. Percent of Supply: 4 % Runout Air Velocity: 482 Urr in. Actual Winter Infil.: 9 CFM Actual Loss: 0.121 in.wg./100 ft. Actual Summer Infil.: 5 CFM Item Area -U- , Htg ° Sen - . Clg;: = Lat;; Sen-, Descri lion - .. -- _..: Quantity' Value - -HTM ::, Loss ,-:. HTM .;. - :Gain . Gain E -Wall-12E-0sw 11 X 8 63 0.068 1.9 120 1.2 0 75 N -Wall-12E-0sw 17.6 X 8 115.8 0.068 1.9 220 1.2 0 137 E -GIs-1 D-cb-o shgc-0.3 16%S (2) 25 0.350 9.8 246 30.3 0 758 N -GIs-1 D-cb-o shgc-0.3 100%S (2) 25 0.350 9.8 246 11.6 0 290 UP-Ceil-I6C-3017.E X 11 193.6 0.032 0.9 173 1.3 0 248 Floor-20P-2-1 11 X 17.6 193.6 0.047 1.3 255 0.5 0 91 Subtotals for Structure: 1,260 0 1,599 Infil.: Win.: 9.1, Sum.: 4.7 229 1.219 279 0.337 194 77 Ductwork: 955 695 People: 200 lat/per, 230 sen/per: 2 400 460 Room Totals: 2,494 594 2,831 Rhvac Residential L�gh4 Commercial HVAC Loads Ken tumphrey Eltte Softinrare Development, lnc Beverly Chesanek' PortsSamt,Lucie fL 534983 _ Pa a 10° betailed .Room Loads -''Room 2 * ' Foyer (Average Load Procedure) . . ,Genei'a8 J --- - - Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 11.0 ft. System Number: 1 Room Width: 5.4 ft. Zone Number: 1 Area: 59.0 sq.ft. Supply Air: 25 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 3.2 AC/hr Volume: 475.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 2 CFM Runout Air: 25 CFM Percent of Supply.: 7 % Runout Duct Size: 4 in. Actual Summer Vent.: 1 CFM Runout Air Velocity: 290 ft./min. Percent of Supply: 4 % Runout Air Velocity: 290 ft./min. Actual Winter lnfil : 2 CFM Actual Loss: 0.097 in wg./100 ft. Actual Summer Infil 1 CFM Item Area . _ . . ;; Ht Sert : . -U- J '"'. CI t' Lat Sen: Description .. Quantity,,- Value HTM . Loss,,,' .:: ,HTM Gain .. +fain N -Wall-12E-0sw 5.4 X 8 17.2 0.068 1.9 33 1.2 0 20 N-Door-11 D 3 X 7 21 0.390 10.9 229 10.1 0 213 N -GIs-1 D-cm-o shgc-0.3 100%S 2.5 0.350 9.8 25 11.6 0 29 N -GIs-1 D-cm-o shgc-0.5 1 00%S 2.5 0.350 9.8 25 15.6 0 39 UP-Ceil-16C-3011 X 5.4 59.4 0.032 0.9 53 1.3 0 76 Floor-20P-21 5.4 X 11 59.4 0.047 1.3 78 0.5 0 28 Subtotals for Structure: 443 0 405 Infil.: Win.:1.7, Sum.: 0.9 43 1.227 53 0.347 37 15 Ductwork: --- -- - 308 - - - - - - - --- - - - ------------- -- - - -- - ---- _... 137 - Room Totals: 804 37 557 Rhvac Residential, Light Commercial. HVAC Loads Elite Software Development, Inc. Ken Humphrey Beverly-Chesanek. Port Saint LucFL 34983 ie Page 11 Detailed Room'Loads - Room'3'- Bath-' (Average Load Procedure) - General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 11.0 ft. System Number: 1 Room Width: 8.2 ft. Zone Number: 1 Area: 90.0 sq.ft. Supply Air: 42 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 3.5 AC/hr Volume: 722.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 2 CFM Runout Air: 42 CFM Percent of Supply.: 5 % Runout Duct Size: 4 in. Actual Summer Vent.: 2 CFM Runout Air Velocity: 479 ft./min. Percent of Supply: 4 % Runout Air Velocity: 479 ft./min. Actual Winter Infil.". 3 CFM Actual Loss: 0.260 in.wg./100 ft. Actual Summer Infil.: 1 CFM Item Area -U= . Htg,_, ; --yen, Gig :. -- Lat Sen.! Description : - . Quantityi Value - . HTM :=. Loss.' HTM Gain, Gain. ;. N -Wall-12E-Osw 8.7 X 8 57.1 0.068 1.9 109 1.2 0 68 N -GIs-1 D-cb-o shgc-0.3 100%S 12.5 0.350 9.8 123 11.6 0 145 UP-Ceil-16C-30 11 X 8.2 90.2 0.032 0.9 81 1.3 0 115 Floor-20P-21 8.2 X 11 90.2 0.047 1.3 119 0.5 0 42 Subtotals for Structure: 432 0 370 Infil.: Win.: 2.8. Sum.: 1.4 70 1.221 85 0.330 59 23 Ductwork: 321 226 Equipment: __... ...... _........_ _. _._ 300 300 Room Totals: 838 359 919 Rhvac Residentlal >li Llaht Commercoal HVAC Loads Ehte Software Development, Inc Ken Humphrey Beverly Chesanek. P_orfSaint -6 ie FL, 4983 s l�' p =.Pa Detailed Room Loads -:ROOM 4 : Bath- 2 (Average Load Procedure) 1. General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 11.0 ft. System Number: 1 Room Width: 7A ft. Zone Number: 1 Area: 81.0 sq.ft. Supply Air: 22 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 2.0 AC/hr Volume: 651.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 2 CFM Runout Air: 22 CFM Percent of Supply.: 8 % Runout Duct Size: 4 in. Actual Summer Vent.: 1 CFM Runout Air Velocity: 250 ft./min. Percent of Supply: 4 % Runout Air Velocity: 250 tt.hTfIn. Actual Winter Infil.: 2 CFM Actual Loss: 0.073 in.wg./100 ft. Actual Summer lnfil.: 1 CFM Item Area -, -U= Ht . g Sen Cf g =.. ; . ; Lat Descn iion °. want _ ', ,Val0e HTM,; - Lass .... _ATM, h .Gain „ Gain N -Wall-12E-Osw 7.4 X 8 46.7 0.068 1.9 89 1.2 0 55 N -Gls-1 D-cb-o shgc-0.3 100%S 12.5 0.350 9.8 123 11.6 0 145 III UP-Ceil-I6C-30 11 X 7.4 81.4 0.032 0.9 73 1.3 0 104 Floor-20P-21 7.4 X 11 81.4 0.047 1.3 107 0.5 0 38 Subtotals for Structure: 392 0 342 Infil.: Win.: 2.3, Sum.: 1.2 59 1.216 72 0.338 50 20 Ductwork: - ... _ ._.. _._._ . _ . . _......._._..._ _..._... 288 _... .- . 118 Room Totals: 752 50 480 Rhvac Resident�at:& Light Commercial HVAC Loads Elite Software Development,.lhc.' Ken"::Humphrey Beverly,Chesanek: Port Saint Luae FL, 34983Pa a 13 Detailed Room Loads =-Room 5 - Bath 3 (Average Load Procedure) General —771 Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 12.3 ft. System Number: 1 Room Width: 11.0 ft. Zone Number: 1 Area: 135.0 sq.ft. Supply Air: 53 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 3.0 AC/hr Volume: 1,082.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 4 CFM Runout Air: 53 CFM Percent of Supply.: 7 % Runout Duct Size: 4 in. Actual Summer Vent.: 2 CFM Runout Air Velocity. 611 ft./min. Percent of Supply: 4 % Runout Air Velocity: 611 ft./min. Actual Winter lnfil.: 7 CFM Actual Loss: 0.420 in.wg./100 ft. Actual Summer Infil.: 4 CFM Item Area.. -U- Htg Sen : , C}g Lat Sen Description Quantity Value HTM : ,: Loss'-- --- . HTM " . -- Gain,, - Gain N -Wall-12E-0sw 12.3 X 8 98.4 0.068 1.9 187 1.2 0 116 W -Wall-12E-Osw 11 X 8 75.5 0.068 1.9 144 1.2 0 89 W -GIs-1 D-cb-o shgc-0.3 16%S 12.5 0.350 9.8 123 30.3 0 379 UP-Ceil-16C-3012.3 X 11 135.3 0.032 0.9 121 1.3 0 173 Floor 20P-21 11 X 12.3 135.3 0.047 1.3 178 0.5 0 64 Subtotals for Structure: 753 0 821 Infii.: Win.: 7.4, Sum.: 3.8 186 1.218 227 0.338 158 63 Ductwork: 608 288 Room Totals: 1,588 158 1,172 Rhvac Residential-ALight Commercial Ken Humphrey HVAC Loads Elite Software Development, Inc. Port Saint Lucie FL 24983 - - _.-Beverly:Ghesanek Page 14 Detailed IRoorti Loads - Room 6 - Bedroom ' (Average Load Procedure) . General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 17.8 ft. System Number: 1 Room Width: 11.0 ft. Zone Number: 1 Area: 196.0 sq.ft. Supply Air: 114 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 4.4 AC/hr Volume: 1,566.0 cu.ft. Req. Vent. Gig: 0 CFM Number of Registers: 1 Actual Winter Vent.: 5 CFM Runout Air: 114 CFM Percent of Supply.: 4 % Runout Duct Size: 6 in. Actual Summer Vent.: 5 CFM Runout Air Velocity: 578 ft./min. Percent of Supply: 4 % Runout Air Velocity: 578 ft./min. Actual Winter Infil.: 9 CFM Actual Loss: 0.214 in.wg./100 ft. Actual Summer Infil.: 5 CFM m Area -U- - . Htg :' Sen ' -Gig .: f - Lat ,, Sen tscription_ : , Quanti;,,.. Value_ HTM. ;. -Loss , - HTM - ` : Gain ; . .Gain W -Wall-12E-0sw 11 X 8 63 0.068 1.9 120 1.2 0 75 S -Wall-12E-Osw 17.8 X 8 142.4 0.068 1.9 271 1.2 0 168 W -GIs-1 D-cb-o shgc-0.3 16%S 15 0.350 9.8 147 30.3 0 455 W -GIs-1 D-cb-o shgc-0.3 16%S (2) 10 0.350 9.8 98 30.4 0 304 UP-Ceil-I6C-3017.8 X 11 195.8 0.032 0.9 175 1.3 0 251 Floor-20P-21 11 X 17.8 195.8 0.047 1.3 258 0.5 0 92 Subtotals for Structure: 1,069 0 1,345 Infil.: Win.: 9.1, Sum.: 4.7 230 1.220 281 0.339 196 78 Ductwork: 838 613 People: 200 lat/per, 230 sen/per: 2 _... _-.. .. -............ 400 460 _ .._.... Room Totals: 2,188 596 2,496 Rhvac Restdentiats< Light Commetcial HUAC Load__ s i r Elrte Software Development, Inc Ken` Humphrey Beverly Chesanek Port'�SamtLucie FL- .34983 •: .. � � _ Detailed Room 'LvadS - hOOM -7 . Bedroom 2 (Average Load Procedure) Gerierai ° , . Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 12.7 ft. System Number: 1 Room Width: 11.0 ft. Zone Number: 1 Area: 140.0 sq.ft. Supply Air: 61 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 3.3 AC/hr Volume: 1,118.0 cu.ft. Req. Vent. Gig: 0 CFM Number of Registers: 1 Actual Winter Vent.: 3 CFM Runout Air: 61 CFM Percent of Supply.: 5 % Runout Duct Size: 4 in.' Actual Summer Vent.: 3 CFM Runout Air Velocity: 701 ft./min. Percent of Supply: 4 % Runout Air Velocity: 701 Uff in. Actual Winter Infil.: 4 CFM Actual Loss: 0.552 in.wg./100 ft. Actual Summer Infil.: 2 CFM Item A Area Sen " g 'CI ft Lat ` Sen.; 1"Despriotin ;; QuantiValue, ,-; HTM ; -.;:Loss _ , HTM ....> .. . _. Gain _ Gain S -Wall-12E-0sw 12.7 X 8 86.6 0.068 1.9 165 1.2 0 102 S -GIs-1 D-cb-o shgc-0.3 100%S 15 0.350 9.8 147 11.6 0 174 UP-Ceil-160-30 12.7 X 11 139.7 0.032 0.9 125 1.3 0 179 Floor-20P-21 11 X 12.7 139.7 0.047 1.3 184 0.5 0 66 Subtotals for Structure: 621 0 521 Infil.: Wn.: 4.0. Sum.: 2.1 102 1.220 124 0.335 86 34 Ductwork: 462 330 People 200 lat/per, 230 sen/per: 2 400 460 Room Totals: 1,207 486 1,345 Rhvac Resdentlal_ Light 7m�0cal HVAC Loads Elite,S®ftware Development! Inc: Ken Humphrey Beverly Chesanek �Part_Saint Lueie FL'3a,983 . `° - �Pa a 16.'- Dei d6d Room L6cid§'='R6om:8". Kitchen (Average Load Procedure) - Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 13.6 ft. System Number: 1 Room Width: 11.0 ft. Zone Number: 1 Area: 150.0 sq.ft. Supply Air: 105 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 5.2 AC/hr Volume: 1,197.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 3 CFM Runout Air: 105 CFM Percent of Supply.: 3 % Runout Duct Size: 6 in. Actual Summer Vent.: 4 CFM Runout Air Velocity: 533 ft./min. Percent of Supply: 4 % Runout Air Velocity: 533 ft./min. Actual Winter {nfil.: 4 CFM Actual Loss: 0.182 in.wg./100 ft. Actual Summer Infil.: 2 CFM Item. ., ; .:. Area -U- Htg Sen ` Clq 3 ,-_. = Lat Sen _�escri #ion . _ -Quanti Value HTM S -Wall-12E-Osw 13.6 X 8 98.3 0:068 1.9 187 1.2 0 116 S -GIs-1 D-cb-o shgc-0.3 100%S 10.5 0.350 9.8 103 11.5 0 121 U P-Ceil-1 6C-30 13.6 X 11 149.6 0.032 0.9 134 1.3 0 191 Floor-20P-21 11 X 13.6 149.6 0.047 1.3 197 0.5 0 70 Subtotals for Structure: 621 0 498 Infil.: Wn.: 4.3, Sum.: 2.2 109 1.222 133 0.340 92 37 Ductwork: 468 565 Equipment: _.---.... __.._...._ .._ ........... .. _.... .._ ._.._. ....._.... _. _.._._...._........._. .....:.. 0 1�200 ._.. Room Totals: 1,222 92 2,300 Rhvac Residential & Light Commercial HVAC Loads Keri Humphrey = Port Saint Lucie FL 34983 ..- - Elne Softyaare Development, Ir�c Beverly t;h- s 6k: ; Pa e 1T Det6iled Room Loads =-Room 9'- Dining (Av&ageload Prodedu�e) Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 11.0 ft. System Number: 1 Room Width: 7.8 ft. Zone Number: 1 Area: 86.0 sq.ft. Supply Air: 158 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 13.9 AC/hr Volume: 686.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 4 CFM Runout Air: 158 CFM Percent of Supply.: 3 % Runout Duct Size: 8 in. Actual Summer Vent.: 7 CFM Runout Air Velocity: 454 ft./min. Percent of Supply: 4 % Runout Air Velocity: 454 ft./snin. Actual Winter Intl.: 6 CFM Actual Loss: 0.089 in.wg./100 ft. Actual Summer Infil.: 3 CFM Item - = Area yU- Htg : 5en.., dig-," ...Lat Sen. fjesw;ri tiri ,_ N Quan Value Loss-,-: °- HTM - .- • Gae�, ^ .Gam S -Wall-12E-0sw 7.8 X 8 62.4 0.068 1.9 119 1.2 0 74 E -Wall-12E-Osw 11 X 8 28 0.068 1.9 53 1.2 0 33 E -GIs-1 D-cm-o shgc-0.3 13%S (2) 60 0.350 9.8 588 31.0 0 1,858 UP-Ceil-I6C-3011 X 7.8 85.8 0.032 0.9 77 1.3 0 110 Floor-20P-21 7.8 X 11 85.8 0.047 1.3 113 0.5 0 40 Subtotals for Structure: 950 0 2,115 Infil.: Win.: 6.0, Sum.: 3.1 150 1.223 184 0.339 128 51 Ductwork: 704 855 People- 200 lat/per, 230 sen/per: 2 400 460 Room Totals: 1,838 528 3,481 RhVac Residential 1£ Light Commercial HVAC Loads -Elite SoitWare Development, Inc Keri Humphrey _ _ Beverly Chesanek_ Port Saint Lucie FL 34983 ' ` Pa a 18 System .' POOM Load Summary. Htg Min �F Run Run Clg Clg F Min Act: Room No '' Name Area Sens Htj i� SF ., 33tuh ` CI=M 'Duct Size , Duct :. Vet -:Sens Btuh Lat : Btuha° Clg { C,FM ; Sys, CFM.; --Zone 1-- 1 Living 194 2,494 32 1-7 482 2,831 594 129 129 2 Foyer 59 804 10 1-4 290 557 37 25 25 3 Bath 1 90 838 11 1-4 479 919 359 42 42 4 Bath 2 81 752 10 1-4 250 480 50 22 22 5 Bath 3 135 1,588 21 1-4 611 1,172 158 53 53 6 Bedroom 1 196 2,188 28 1-6 578 2,496 596 114 114 7 Bedroom 2 140 1,207 16 1-4 701 1,345 486 61 61 8 Kitchen 150 1,222 16 1-6 533 2,300 92 105 105 9_ Dining _._.. 86_ 1,838 24 1-8 454 3,481 528 158 158 Ventilation 923 495 1,245 Duct Latent - .. ...... .... ... - __... ..._. _. _._.._...._ .. _... ._ .... 1__089 __....._...... ._... .. _.._ . _. _......_ System 1 total. ---- --------1,131.. __...13,853 - - - 168 ----- - - -- _16,074 5,234 -- ----- - 709 _.. - 709 System 1 Main Trunk Size: 10x14 in. Velocity: 729 ft./min Loss per 100 ft.: 0.098 in.wg Coolie S em Sumriza Cooling : 5ensibie/Latent ;;'Sensible Latent ; ` = Total - - . _Tons-;; -:. -S l;;: - ... - 8tuh ; ...._.. :, .,- Bath: ;. - ..: - - Btuh Net Required: 1.78 75% / 25% 16,074 5,234 21,308 Recommended: 1.79 750/6/25% 16,074 5,358 21,432 Actual: 1.86 74% / 26% 16,500 5,800 22,300 [Equipment Data. Heating System Cooling System Type: Two Speed Heat Pump Standard Air Conditioner Model: UB024 UB024 or Equivalent Indoor Model: Brand: Description: CENTRAL AIR Efficiency: 13 SEER Comment: HSPF 7.7 Sound: Capacity: Hi: 0 / Lo: 0 Btuh 22,600 Btuh Sensible Capacity: nla 16,500 Btuh Latent Capacity: n/a 5,800 Btuh a>< Florida Building Code Online 6r •�� Page 1 of 2 a. s *� EJ101 Ewt BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or ADDliCation Search > Application List > Application Detail FL # FL11968 Application Type New Code Version 2007 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Eastern Metal Supply 4268 Westroads Drive West Palm Beach, FL 33407 (800) 432-2204 Irodriguez@easternmetal.com Bill Feeley Irodriguez@easternmetal.com Shutters Storm Panels Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer [�^l Evaluation Report - Hardcopy Received Walter A. Tillit, Jr. PE-44167 National Accreditation and Management Institute 12/31/2010 John Henry Kampmann Jr. i.-Z Validation Checklist - Hardcopy Received FL11968 RO COI Certificate of Independence 08-0521.01.PDF Standard Year ASTM E330 2002 SSTD 12-99 1999 http : //www. flori dabuilding. org/pr/pr_app_dtl. a spx?p aram=wGEV XQwtD gsxYIeb 4op OD f... 3 / 11 /2010 Florida Building Code Online Page 2 of 2 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Method 1 Option D 01/02/2009 01/09/2009 01/16/2009 02/03/2009 Summary of Products FL # IlModel, Number or Name Description 11968.1 0.040" Bertha Aluminum Storm Corrugated aluminum storm panels retained or not by Panel (2.25" Deep)- Non-HVHZ - tracks to provide hurricane protection. Drawing Number 08-145 Limits of Use Installation Instructions Approved for use in HVHZ: No FL11968 RO II Drawing 08-145.PDF Approved for use outside HVHZ: Yes Verified By: American Test Lab of South Florida Inc. Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Large Missile. Max. span is 12'-0" for +25, -25 FL11968 RO AE Product Evaluation Report 08- 0521.03.PDF p.s.f. and 4'-0" for +125, -130 p.s.f. for sections 1, 3, 4, 6, 7, 8, 8A, 9 and 11. See sheet 10 of installation Created by Independent Third Party: Yes drawing number 08-145 for other spans and pressures. 11968.2 0.050" Bertha Aluminum Storm Corrugated aluminum storm panels retained or not by Panel (2.25" Deep)- Non-HVHZ - tracks to provide hurricane protection. Drawing Number 08-141 Limits of Use Installation Instructions Approved for use in HVHZ: No FL11968 RO II Drawing 08-141.PDF Approved for use outside HVHZ: Yes Verified By: American Test Lab of South Florida Inc. Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Large Missile. Max. span is 12'-11" for +30, -30 FL11968 RO AE Product Evaluation Report 08- 0521.OS.PDF s.f. and 8'-2" for +75, -80 p.s.f. for mountings without " header. See sheet 5 of installation drawing number N-141 Created by Independent Third Party: Yes for other spans and pressures. 11968.3 24 Gage Galvanized Bertha Steel Storm Panel (2.25" Deep)- Non- corrugated galvanized steel storm panels retained or not by tracks to provide hurricane protection. HVHZ -Drawing Number 08-142 Limits of Use Installation Instructions Approved for use in HVHZ: No FL11968 RO II Drawing 08-142.PDF Approved for use outside HVHZ: Yes Verified By: American Test Lab of South Florida Inc. Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Large Missile. Max. span is 9'-8" for +30, -40 FL11968 RO AE Product Evaluation Report 08- 0521.02.PDF p.s.f. and 7'-2" for +70, -80 p.s.f. for panels mounted without "H" header. See sheet 4 of Installation drawing Created by Independent Third Party: Yes number 08-142 for other spans and pressures. Back Next DCA Administration Department of Community Affairs Florida Building Code Online Codes and Standards 2555 Shumard Oak Boulevard Tallahassee, Florida 32399-2100 (850) 487-1824, Fax (850) 414-8436 p 2000-2010 The State of Florida. All rights reserved. Prlvacv Statement I Corwriaht Statement I Accessibility Statement I Plug-in Software I Customer Service Survey I Contact Us Product Approval Accepts: 99 M Vu1519ta ` S�curad ycurn http://www. floridabuilding.org/prlpr_app_dtl. aspx?param=wGEVXQwtDgsxYIeb4opODf... 3/11 /2010 e-I IL In CD 00 N N W IT ru N N 0 F-' IUJ b ;: � •' - .• + �• ,£-`. - - - ter!=, , :.. '•_ ;, w� ► '' _i `- ' .�-A. _ .-' - _ �. •'g. - - _ fir: edaY�:�``�T�.ay�•c{�,=��L[ �. `ii�`�;�rt i?j^� I�'.., ai f�('`'i`�r,+�r`�:ft�'e�••!'% KAS {'` A'SM Ho boy 1rt User Recit&a ian cs Gu rem p�tl[ca lots st ff }n �s Search kin Product Approval USER: Public User Product Aaaclral Mena > Predo, or ARpli eiom Seach ,> Application List !f+{ i,�,,�i' •' Search Criteria >. ��li S 't. .8 •. i. Code Vers' ton 20a7 FL# t - �,,. :: �f • �' Application Type ALL Product Manufacturer Category ALL Subcategory Applfcatlon Status ALL Compliance Method Quality Assurance Entity ALL Quality Assurance Entity Contract Expired Product Model, Number or Name ALL Product Description Approved for use In HVHZ ALL Approved for use outside HVHZ Impact Resistant ALL Design Pressure Other ALL Search Results - Applications �" M• S`. i Tune �� t _•_ :: M u aj ure_r_ 'FL11966_New Eastern Metal Supply - _• _ _�_...__ FL#. FL11966.2 r. 's Model: 0.050" Bertha Aluminum Storm Panel (2.25' Deep)- Non-HVHZ - Drawing Number 08-141 _'? = Description: Corrugated aluminum storm panels retained or i not by tracks tv }lrov a hurricane protection, . -� � Category I Refine Search 11968.2 ALL ALL ALL ALL ALL ALL ALL Validated By -Status John Henry - (Approved.: Kam pma nn ]r. i t (941)922-3854 r - r i I FEB-9-2010 12:00P FROM: TO:17724622885 P.5�15 2-d ..�+'.•i��a+VYYV...✓r.nnoJ'<tl,�•ww+r�.�. J...�. �-�',..L�.. u. 1 i r i i Q N ' Y N c �n x N 1 [•r .j[Oj4,1! I i � o:wM�aa o Alt 3. o Nmg4C 1 awgyma a o a i I 1 , GSbE6bELOb mouesa43 laawo;w UL2:60 0I at uer J 5'L•v rs•tt ]..s PFnt.:: - s.Ta•; trf v7 (:rCJ LJ; 3::- .C.,.e7 ter c:•,•�;f-G° rs A�14s.L's �•S SY.tj .'a:GS Bl ri h:q•t.� �' iC, r i^r ��p-:(ai :•:+f: lr>4-!.I.iEf 6 st7 lQ.a=._x -zr; xi^ �.e: a� :F +ra 4u If.... �T M_s S'r 'K .NCf k.,T�7 ,!£:e. Ko n3 YES..x a• ram'_ •t`:'..Y. s v.._ S:=r 7,iti_ 0" dr Ar LL' AV ft31 S? CP kN :� a. R4 f-L•ri+•x{_ io.J+ 8A 1-97 Tf.V[7ar? K 621a h• -MY NO crm- :s of •ta i.£A Ii imei fh'v w,T :15� TafS�%. , tYAr�C h �:a- S'f..iY f e'q JL:,: e'hi5 LS''g :Sti W W-: IMIMS A Rt. At OF fl iR4o3 B. 0-1 S i'S'• r Sr. Z aJ �+J_r rs ml %: r.'3 C'.OX P_37l1 ALF 6-A +r?YEJ A' a:Sta,:tt:.r FT.f S,., IS�J,7z rr .HX J.:._ tE:: J�., rw AS "a3. Arv=.s 7Jr.D:-sib 14)2Jt71-!A /G4156t_a3iV%-`•7 J-.st.; ti Ire 4s'a LZ-i7 sv ;L+',f J Au 1iTJ1AC.0 i-SF.• mma Pswas rtc w a'.Y-r.R rri K :r-hJ4 4 Y +.L A' VI !" Ii:r•974 S. T.f A:L'f4:� ^a w'+if-r- kLGr k :iv,- l+s.fxL tJ S!=.i -- S.Y.•Itrd:. Cl� .5w,, 1 SVtL't� �iA:r J.�: 'ie S•--D t'AA= CAP /cE Jie:QT h i•JF < ILL eL7it4s :f: iS5 5711-4;!S.S 51JFL }f 09 :Jt.ey SF� yi [Lvi(gyr mS�Ayr �,se� tdtYf S.iJ: AS ijt G7. Ea.n MIS S'•rA;rY A..P 2.1 kV .#:W S'fM: J• &N a m Sd As.1r A-JJr GJ:.iA.Tea fzr& sa' rp X. g? S %fW .TS':s wwAv NELC 5: <FtiSii S Ati::•C=7S T3 -4f SIR: -'C - -VL-IM (.Aln$ 7:-MGf IrS.,,�,• isi :G r" •S:JS :Cc-= CMZ?FFy 14AC". Z 6 T.b 1• Cf i.• 1Pkh:iYSY T:Y-PY-J IS Jf4•.wr`!i C4P£7 N ?V-tAi• %f ! LNIC irS;:J 4'ANU5 AT.eas../.'i7fi 3I P:y 7 JRf 'L•S. It,:• ✓m'/-r _ a/=•CK -ff 4T:rm•LT Of hR'r..Y 1 frr;[ 7A.4al 7-.LC i'F•'.1'A_rWID ofL Rs7 Sze. /i.^kiY( Srst.fL LC.. ALbtL:. i:i . f/r' • r Tfj' J..f F4,4"5' ixG-$.R A'AYJ.S AJi E•S.:aT.'T_5 cY ICI F:rTS SCJti I• F? STCj ArJ Jf tti':Y £.ri!:r_1- nr!J•o,'c:: t='kG?f;i tF Ll•YLf i•C•iJi �' f 4"; riz Z.L-- M_ v [`A:.+rLS 6 1 use f" L!CC 7m1`_WE s ysi S ! J•/L'po APt L+ 1 -C�-Ir ,may : fig S r r/f A.Ji J13' [4Y-Y LY•L-,S S*w'L fi- 0?.:P I L,'-; LetiL et f7t:✓ a :/fY-!: S-•=fAT C= s--C:. 6 i UJ•J•n.0 VeZL.frf S+ALer S•rM CAS: AFC f' or r a FO f4fS W-.W an s:,-LW 4]� r':Afyu iJ+iFSUE(r Gr f/t's r Yl- `AhL F4v-7s FCLs-LL7 A. A•s Ste:. RC T/!• K•; F+t PG:r i G'afCG:E +4 F+I•stdA, all 9^.C.V Sa11. CC TC-,j-.eA .,,e r-2C 6.4. W, - SC7is 6�7 Sala jr .L1.rY fAbl ti SrS"4 CRSS As'9 J' Sant Y ffrf f.vu nX A'S 3 :x ILA; rI rasp >iN Pf wb Srjx.. ;Csa 7 CssX•£ P•ACis: CK PA4 m Y ISRJ v. o-r O-i•:. w+� f r,/ ; •'KCJ+S Ate.+: R I v.:+3t c T;;A?r r:e .•W, b'44S:P5 S.A:A J'J:E.,S Is'JL•Pr a 5%'.i ft PS CA wiS r.fi A-AFJ Ara.' (rj rLrNS c : T e=A 6"v- %s. s rrP�L� s�"G'S u J.aR: C'.r� f err Fkida :/•' I M rAP-_ r A;{ W 1 •Y.1 Ftr 46SVIA'L•i V4' • r+IieC Kt b t--MW AS kux!J <C'r Cr fpN£d %S:;•L M t.0 r 7/!'rt6Y A%Cfeln 4: hCO .r i k fr_C. finZk*;VAF VAArt;'.%Xp Jr- r Y/*- A•.:-P..Pz py..•-•_..U- i 2r fir ii LWP ft-A Eral M%-i -P(?. •,r9[- r d £ rCCU--AW.. C[Vr-Cr =17W IVS'CF: AJ KIfC.re: �'s:0 JW 11, r»'L 4:'FS• d fi N.4v'4 L1'P`- k: EY CA CIA r"6"44"!; AL CY 7d?•f.?=.41v-P_r P. L:ar SAt:l S: r }/f : r _9/Z•' WLW$' k�CA �AG•+G 5 A, r JJ$" s.7T. iC 1 x Z.Al ?ia E>'I 7/j• riff-L'• +r."hTS rht:! CC t 3;%rcu a.'-=- 64= fCr:trf ... SJ c m.:v haw a:t,t rr 4"ue sc%`5 45M Ewa ez f r/t' ;:6 Y1J(:v 9191D SSaL10 r1.5; 49 f' e�J va a is tvAtlr_s' 31 V49.. 4 4• Jta f•!FS S tC s•T 4,4nt• . s.A.t Fs >ld' o ^� tGti:+Y'S RTt xJ !V_St'f-ir fi : SlXO .Oal :i P� /i• r-M NY. V+.!M1 S-cv; SU:.E SC:gA• LX9 S.:L E'E t ff{• L.1'c +•'rtCV C-+ C49 S A-1 J • A~v $iA RZGL JIT,f fu diJ : f l•isC V -, A-U�.'d :i rSL�i{:f tP9YR':7t'�41r JatA DY :at E75:a: K:. ti-J+T S.Jft 9C a q J.:3 ! j /ivN IE uA v S'J¢ C' •:� srr �+ats f n lXaa s.SC 5f Af Qw-b a' ICJ r:.CMJe! S7.te4 e: hTA.:.CP ra10.n•r A,-C C, Ati .w*,- 34U:+%s lc4: f•E'J'1U'S{; Cr 'i¢'st;.CaS Na.:utff .IPZV J �tr_a' fell. S3 E!.]T.lf: ••r'a:VI.Er'I:i::M:! C.i;11.I-St .S!•%t5' S�:d1' r*:eCf•_•,t . ;v`.J 8 (sAES J k ! Jr 9? faZT` F•J: hr4wA A ! f MAL .7r £r :'Sr+i *ftl a c• 9Ls.Js9L:y £r� r rfa r grr ue ssey.•sa: w F%T Lsxa+ta .: s r r e r ee 2 C?4C5 a �•:. ;C F.caAt� 4its.•aA;r •r_ YiTi2 rS GY! &',f:Sk-.+i- 77 LLI:+LY F'Y,T GT r^„'. I••+-p+C oi4TCF�CV ECV'AAC,Zf r. Y S'EV/".tixi At s+-: [� C!'.�C^ ca -ow fvAry 7;J F!C.�L�r Y.•+'Ii ;'T fst�;.N. Cr:Sr I>C. SCA. Ste: ' 'A-r_ hC kYn:.V r/� I¢ ;; vS PE+-.�4171SS PI r`LS L/CVrY ti Cc'Nt:F: A1'C DOG hs7 lrc.t�t' :va•:.nx,•. ,Z9 J W,AT t: S:"•Z CEd?:!RT Le^Js� M7�r us FFC.. (-1 L%54c xq ra rx 02$•'C75AE A '.- Y-:t CC YVC6 -T- &W aM;:l1r[4 i:6N-1C J4 Z _-T Cr DAS r+- iaSr9 Ob •+L; :•,f w P'C r6i%'�'v: �I LC:.K I;r OC A r :i.•�+a ,:�:C7 [T :n3 Y.:Cit'\'. •x;f -V + .7. J -�S F.U. OFAL :Z K-%M J S.YzO FrA\Y 6C1:S (L' -%f` Srt�C .'V11e::i S1w tr J•-FAFm Ors 4-Al- Fi,-W3'V 9 f,:1Cr/ SS A.:.-.-Cr MVI( ►U =-2w r r rwmwx _a- Fulwvc (1-6A) or* a.0 r-a a•.: J1C FCF/.salI r[a -C Li-� & tx w rL2 [A.CPC✓ SF .1 +S A. -I..; y / ie:tiH �7 �.9.:.V r� Jrf -Aa 84aL_'e'i S'r...k S.�N7 F3 r+S iA--P. m VXV-E WJJ':&5 W. .-I..; f Cr: .'J-y I` O PA?:: SS{Y C : r/Z .iF7 L:G-'.ft :FA, At9 fi SW 995 Cr :: Fi -Jum , ib_ _l- Ae.Vi 2 Pay IT. S N-EV UNWAAiILc4e7 Loam 5-.V.9 FE L'wm &t A, : 4i.Er V1 a S7-V FAJ J4dd� I:tL17Gt4G5 k4 SCCi.'+.` J]•JlE3 fr l fxJ. 2.tlZk,T Mi. D.£ et SP:4L A F.KT.+ r«• E1£4' G•i.�'�.. .Pd::4 'XIL2 e? t ", !JJ(JJz CT .l AiwL d=..0 C:u'r. 1..• i rAc. kaa fth Vq&xi•/ iJ:rRJPOre tor•., .rrx rcTs ,-e �Rrm J4Vk!.:.L.V�VC.R4f PAWS LC ff I �::r •' : 4�T•`� ` :• EASTERN METAL SUPPLY INC f y�� IEC 4N rCr ris iwt �: �-_��� _ -T f1tE •u -�I - tLL•r flf iT4.[ LTi•.fe[�Y6 :iV +,[�,-;T•�.r ��•� rang ar.-rr tea.. �, •-'F f�Y 15C1. �1>♦:r n:+r pf-;re+-ral rw pe aau-.rf C2-!fJ .:. ryil i•�••XLF•I � r� ILt Aea...A J.rl, f • G+f.•:e .k -Ti m L 0° N t^ m m Cr j CED C -0 0O d 3 4 C U a U� GO a -- t� N Ql N fl] CD m kA jilt -Re S.lP�ri.i�l.YHy�7�1r4J".�'[iC� APY OHI 'AlddnS lYL311 NHUSV3 •a"t 033 vu stiir -,=S (ZI at Armid j 7Z*W JV 3MWMW rsi .-�pyy� •ram ff as ma r+A aas-1f �T.'Yli9 IL O�i p.Am .. •.r w •.a*•Ra •-.rr.• av s .n <m �I 1r1 'JR7YW 11:i�. .T .L Q3py 08 jj"—&Nw mw X 0 _ • ' xr 3 m► r t .rr g lrra QunB .m .'sm.F Q Eq O m � N a. m mD NO ri .i MCD CU U rW Q1r7 CO W LL .1• r..-r•u X -Aro,S 1 .d !i 31 r i 1 .1Y 1T.1 .1 ..t1 Lg 719kIXZ5. cei ,.r R 1 v..R �s90s still 7.w. ff'r, C• w�rr�ra,1 1' 1 surf . N .—, .1>cr Jawa ! .tar. .Kr acea ��7cstr-&=J.FWD r-,tn ry qq ,i Qirii p tYs i 1•--•N� assG arc s--2 f-ant*•---•: r c---j-.BI'!1 ao n: i. Ln CD m CU ru T CU N N e-I 7 f 7 r JIt-86 Or-,rW.K`sntxa-"VA!Toi NOVAVr.ii�ioi:��.'.rC.. �E��� .• • . ssaa� � ar a. My 0'9 '.lWAS 1Y13Y 1181SC3 Jsj:T :-+�:Yd X�YiS YNVIh'77! iHilf3F .OSO'0 x �a ter. - 1 �,':• ^ v� • " r� :•'? r9r3j Al." S 4F-W L'*Afj J8'1 {a +� n 1131zS .SV, �.OdJg7 JUT1' M na;l !fi!: /. lTari Sv i4�nG3 ib'J T:26 d� • .. _ .iiJ ' i TwlS G4 1 NCII VA313 773ldAl 73Nyd j9a5ji ti7/ i 1 1 1 1 •.�-�-� ,� �� Ali :•� '�S? G5 3s"S) 542+rr (fin J ` ara;.t l• •5.' R3YS_ V C Y C9 IG11lr� lJw.:.y7• rbr. �S Li ;P1 iMp! fi?tMZ�JYf•A'Ki � G+W4J.%f• 'J1 •Gi S?Od r.. S•l••G _ S ,OCR :lfJ Citr %T ZCt� I I e� e rC+s un.,t, I ,.v .3 �cs rrer.+ —rc r. SoT V Wo- hSr r10 a '++C'+S /�` • n�c sa•.e_t6 � � Ne:K fir; ♦Ca, Q] w:J $ O 4 I or d4..ir .Yl:/ rnrr wYP Z ^ M,YRL Opp<!a •t0-r Ow +� n�. (riwF.MiR �'VPJ ;1R to hYs{! lY ypr�l Ct(i' r7Ati 9f i�'iAQ' �~i3+wv++6}01t% rM sw"j 3xacv r L14MIR WALL MOUNTWO JKSTA!!A7j0.V OULD OUr INSTALL4TION SLR CTION 2 acur : r SEC fJON J ;.sc : » i 511 + xxn� o, /-1-7,774 K Trw as.sr..: v s:_rgir. Fft l!f['+JYdOlYO_ L:rO.•+l 1 IY O L [PRKOa.ly 4as S sur hc/�57W%lJcl .it rlS.F� s-G•-;are:r-r� ,n..es 1�S°�^• ,ti.f rY`Jj:;. WA" 'VOUNT(NG IIlSTALLATION WALL NOflWING IMSTALLATION SECTkTN ! sti+r. sa _ r• SECTION ?A -t �t c• anror o rro as s,a: rop ' � rs r 0 ,'YtiV.J r �u•at; � C�GA106 ai—� ~ r. W IPrxn» �: � OP•C1► C�i7G�i� �t n�vrrwrrrr:+.q BUILD OUT //ISTALLADOIY SECTION f cre: zn-- r- rru �r::a- rr. o.rlyD- FERTM /iM!'tiY,r! 57crar P.t'�C t725' ar ' i cPr pwF w OEM...' awrCswa :r..r �h s, ,rs�o..�en rr fl-Clit�:i r''neEryi e: �i u�eL EkSTIRM }METAL SUPPLY. INC ►'�, �tv Y.o;IL F4, M'a fYVT.+-sY-s ni, i>:Ar:--`Ar It-71t r�• �a•r 9V: s a r m m m fY � 3 rj t m �m CT C9 a-0 fC m b O 3 r O 3 {U Cl. 3 OI 3 to PC , 0�t �I ►�.rro _ -'h q V arts• x..a.:r rn r .ssas:�a.:.oro.r •arm s�ce. as.b :. r: sir rrvr rt atp r r. !- .rJtaL-� .Z-:' fPIA•9 ��• 1 t'.11 II 4,IC v f f i 9 Cex. I 1 � 1 � rY/�. r.U•/n. f' f I f' iyry 1 r. J'QT rfd:7 �H / I G.LLC I 4 r. f o c f I L yyYY, •,,�.jT > /crr te.tir � • rY a c w Our Mr.4L�L1rlay s^ECrwN S X" . W. 1• Ij/ CCY r r r +srneaor:...j � arcc�.vn •,.{:t.;•� t .rs�c I, w.tra 1I rtiar �iw�usra ---• r o iid.�,.c T"J�as°`�i---t a (.ec armor nr Wtv.: (4.'>btY'l r'Y n'CnS CMINC & FLOOR MOWWO CS UNZIP d FLOOR. MOUNT INSULL TMW - SECrlON 6 INSTALIA7M - SECrfOY 7 iNG rw.:ua: lr L'] J •+" 4'Ot J f ev.&- a !!N S.KDsL lit L'1JG • zc, � , cc fR to ELL 1 c�`ti�vatJ��l�\ CAM I y� 4 1 f a p 1 i 1 q i Ill i II 4 AMC ml I I rcas=c Am lCiV5 "M-Zi t c. my WALL_ MOUMMO I SULUVON (D. - SEMM B :a.eeW -r- m � J x Cl ; w hiL 7:-`¢a UAW X -rllr I r' rn ' a 7.1!itMz ; CJ0-0 `"� 1. 3:s-:•:c ai sxt- ..t::orrze i r• � � Y J' �.:s• �rrwa• t I m -09 a.f ar. Jar ro 07"0- 45 FLfI 9r1 r.7JreT CASE A IPIQn) .Jry,t ws ,L. ray :rrr_^ tie AS£ B ftanf VASE C (Plan) I- S/LI. �f•• a r- �No ctGISUlt f�t�Fr lets �XlafuM DFSlC,I pJ7rc ar Aeff q "rya� J4_1y�_CQ4R£SPONQ!HG i+�Xl.4lUll igim:a �VGT�1 "t. -�^•_ � ' LE F R Cl N PJ kFi SYST rsr :S ` "nrPa`a' *) LUVw V .y3�L1 �m.p1) rKyY.MJ r••- t•erx!a �7 lk.. Jmr- Lycra dill) +.'�'YG >rJ : Ml't N,Yt• r/ a•..a•.� Cj •ras..a-�a� .JXS. -JRC J2 =f r• r2:rf• �.•f,. +J9C -320 f2'-1f• •]='Y J?'-tr- ++3v -SPA 7a'a• _ rsa� -?co a•-�• Y_a- tom. A`?T_ arjrw%t KY£. 4'+Srt 4 J'-7- ?LT a•JCnaf :d i rwcro�• Lao sty I 'Ixwt.lblw l newIr I ( raz I � c,cs —•' ' �' ma rnwJ rrrf-.�Gnr 5t J'+3' 011'J:iS •�tt GR I{ Y' a•+s.rFi \\\ � Jos CASE D (Plan) sckr, r%s• _ ,• r Jcvwcw,--r-- —fm27 rL••r �art�r S �� ' o k CASE E (Plan_) WAM ys• • r- .+ sue• :t�c:.tc trP rov�4wnou rL. Pt+r.• f7. c-st•. -a.•. is sernG rs• sntvq; it:+ LCi13Gr y FwALt MQUATIMO INSTALL.4ti'(JN.- SECTION S%.[ : JJe' . f • .' :y a^�i�•a �.�, . rrax 7r x: I! EC O 1. �C,-'- •' cep •tea_ n a �L c a l:.L CfJ:lY MI:iY. rJIS ar0ef.1 r'Ati`� LgAf rASTERy METAL SUPPLY. INC =v ram• aT rifa m-i..aa ray+lGCJ: ,itilr .•,oc.;.s:ya-ofxAr.t�r•%r•_rr.• Oa-rir �'•'� a.r 3�Y a �, . 4-af - P f ,e DIY hd R•d 1.q*R_E`*RLn4r Hauesa40 TOW401W e82:80 01 61 uer ST/2T*d S88229t72aT:01 :WONJ d2O:2T OT02-6-833 M „ I R h C►t �' • 4 1'. a `4 `1 V 1• y f y .� y` { o •'I 11� 1 I 1 1 V 1 1 1 M I I 1 I 1 � 1 1� b u W , �O I r l 1• ' ,l �{ , i 'S " t I I I 1 1 ;f •� ({ ^g 40 c } 11• � a'; G 4 Y i>i Si v' v. � a 9 u♦•i $ I.`. w C .`. ^�L4 a ► q a 1f 11 1 4 4` 1 `y 1 1 1 1 1 , ., 1 .I1 I. 1 1 1 •• 1 :� 1 *5 ryy�tt Lf 3 9 y 1 i 1L �SSst si3 ;,tGa•. s$ 5G s;t''tgl�� ;laa 1 a S,, V� ,G nl 1� � 1• 1 1 1 I y q v • w 4 b a r w .�a Q �, I 1 1 1 ! ` V 1 Y `� 1 � .� 1• 1' 1 i N 1 I • IS 1 4 M 1 r • 1 � 1 • !'l .b � tl 'I V. A 4 y A 4 i 4 o- w1V ` • •jy{y �'�v r, +!R'i �ti ; q � a�IV YSA ,I nT •d i.a46aa6Fi_n* mauesawn Taeyo;W e62:80 Ot Bt uer ST/2T'd S88229t7aLT:01 :WONA dbO:2T OT02-6-033 -JnRr '2 111 oi 'Amins lvi7A N93isv3 I'JJA-Vd )LVOIS jmrA:s 'Ve COO ;7---#A ZAW WN) W StMA-M Ga" T47Z "US%O* low V" ev -1 4 0 94*0 Zmff. C* J=f 9a- Vrs# ffe 5.VGI -Mv ft-lEm M. mw_ AM ?WV SAMOW" -1 SON1071nil COOAA Offilsoo F--$NOUOY� NO $71VI313 M4IJ477ViSNI SKOUY17VISAN ORIVInOn 7brM JA 11 ya.77-11 V .9 3.4211WO17V p "I ftsm dOlm.-I -.9.1* tL4rLTN -41 ft-fry T v tF-J --M c V17 -.-j 4yd" w jbw 1 V.&F, 4 A- Ll% -, TUA 41A Ax7lj 1-4 t fr aw, r4g.it P-M. Cc E Mw4u &X01=04— 0 0- 0 LL IL (S)oJ. —Or In r. Q " P IMI INLI 0�1111 wo.2 CU C3 -jo.; o x-NX A. St., a) 49 C� 'I w LL t JAIIYAW7 11* rlsloZ aF SYM VF.A I 3A U VMY3i 7 V msim c. --n-f g-�- A Lr) 00 OD cu cu WV ',&WdnS WiM IfU31SV3 Qo cu Mois Ar-v.AInv rV r72 .0�70 JQ74Z Pc-7jJwlr -sk:-,-ZsA ;AW -;:MY '0197 SOMMUtig GGOIA ONUSIX3 NO NOUMVISM] .5-7/VIJ0 03 3 il 3AMYNODW fiOl'1Cq3/.!:)1 'JAL CPLS 0 NVU�S lzfl .lA c3 a JR., SMOIIV77VISNI DVflNnDH WOOV -7 MUM 9 3A 11 VN;i3 W J MUNY317Y 7 JA 0- -AO 0?%TA 4�_W .V.r: '!. Z, 0 &AM4 Z.7 . ".29 M7 V JA -n-jQrJ .'rWlJ W SC12 .7 AL-�W s47_--V A T 'f.V 3a- 2! =-, rw eme -am, --fz. V," xxrj, *_," la; & WiS 51 A W-.& V., .7 S.CG4,57 _K'!,NW Cyr "S ZL­ V.V &If f.-'M A ',W .51be 'AiLlri rTWSVAV APT Oj .-_V AV, W SP VrJ 592M.25 SWANMOF tA,71�V A&M111M, SNOUMMM 9AUMJ701f 71M 0 —MM-171Y I A I WY &vwo 'Lo.-M T'M Mr, M. ollj ffr l-o AA.- 73 0— w! tllffll wx fz"20� V *0.,t a V-.Z.V 6 Mr. Dave Johnson St. Lucie County Building Department 2300 Virginia Avenue Fort Pearce, FL 34982 Fax: 712-462-2885 E-mail: johnsond@stiucieco.org February 9, 2010 Re: Mod-464 Dear Mr. Johnson, This letter is a follow-up to our phone conversation this morning concerning Mod-464. When looking at the floor plan (please `refer to the Florida Department of Community Affairs web site for an approved version of this building floor plan - http://floridabuilding.org/Upload/Plans/PlanID_25658_MFT-68-MOD%20464.pdf), the exterior wall on the lower portion of the plan is identified as having "5/8 inch fire -shield gypsum wallboard" installed on both the interior and the exterior portions of this wall. This plan was drawn specifically for this customer; Mr. Chesanek. This plan is not a standard model plan and the note that indicates the 5/8" gypsum is designed specifically for this application. This home has not yet been built by Jacobsen Homes. While this home is under construction in our facility, a licensed third party inspector, will inspect and verify construction is completed in accordance with the approved building package, including the floor plan, as noted. After the inspection process, a Florida Department of Community Affairs.insignia will be affixed on or about the main electrical service panel, verifying that the processes and procedures as defined by the Florida Department of Community Affairs have been followed. If ! can be of any further assistance please feel free to give me a phone'call at 727-726-1138. Si cerely, Craig Young Engineering Jacobsen Homes P.O. Box 368, 600 Packard Court, Safety Harbor, Florida 34695 Phone727-726-113 8 File t STATE OF FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS CHARLIE CRIST Governor "Dedicated to making Florida a better place to call home" THOMAS G. PELHAM Secretary APPROVED BY September 20, 2007ON A. 11 /10/09 Mr. Mikyo Trevino INC Jacobsen Homes Approval of this document does not authorize or approve any deviation or deviations from the P. O. Box 368 requirements of applicable State Laws. Safety Harbor, FL 34695 RE: Manufacturer Renewal of Certification, ID IvIFT-68 - - Expiration Date: November 09, 2010 Dear Mr. Trevino: It is my pleasure to inform you that Jacoosen Homes, located at 600 Packard Court Safety Harbor, FL 34695, has been approved under the Manufactured (Modular) Buildings Program, as provided for under Chapter 553, Part I, Florida Statutes, for the manufacture of Residential and Commercial Buildings for installation in Florida. Design and production of the buildings must be approved for compliance with the current Florida Building Code (FBC) by your selected Third Party Agency before manufacturing begins. Your Third Party Agency is a contractor to the Department and has statutory authority and responsibilities that they must comply with to maintain their approved status. Expect and demand quality plans review and inspections. Each FBC change will make your plans obsolete until they have been reviewed, approved and so indicated [on the cover page of the plans] for compliance with the FBC by your Third Party Agency for plans review. Please ensure that your plans are in compliance and properly posted on our website to avoid embarrassing work stoppages in the permitting process. All site related installation issues are subject to the local authority having jurisdiction. Unannounced monitoring visits by the Department's contractor will be made at least annually. Complete access to your manufacturing facility and records is mandatory to remain compliant with the rules and regulations of this program. Please visit our website at wwwAoridabuilding.org to see valuable information on the Florida Manufactured Buildings Program. A copy of this letter must accompany applications for local building permits. Sic rely, 1 M chael D. Ash orth ` Manufactured Buildings Program Manager Cc: William (Bill) Tegeler and Charles (Chuck) Osterday, NTA, Inc. 2555 SHUMARD OAK BOULEVARD TALLAHASSEE, FL 32399-2100 Phone: 850-488-8466/SUNCOM 278-8466 Fax: 850-921-0781/SUNCOM 291-0781 Website: www.dca.state.fl.us COMMUNITY PLANNING AREAS OF CRITICAL STATE CONCERN FIELD OFFICE HOUSING AND COMMUNITY DEVELOPMENT Phone: 850-488-2356/SUNCOM 278-2356 Phone: 305-289-2402 Phone: 850-488-7956/SUNCOM 278-7955 Fax: 850-488-3309/SUNCOM 278-3309 Fax: 305-289-2442 Fax: 850-922-5623/SUNCOM 292-5623 STATE OF FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS "Dedicated to making Florida a better place to call home" JEB BUSH THADDEUS L. COHEN, AIA Govemor Secretary DIVISION OF HOUSING & COMMUNITY DEVELOPMENT BUILDING CODES & STANDARDS MEMORANDUM From: Michael Ashworth, Manufactured Buildings Program Manager V vvu'� To: Building Officials, Manufacturers & Third Party Agencies APPROVED BY 11 /10/09 Subject: Raised Seals on Plans for Manufactured (Modular) Buildings ON INC. Date: November 28 2006 royal at this document does not authorize or approve any deviation or deviation from the requirements of applicable State Laws. Section 553.80(1)(d), FS specifically exempts state approved manufactured (modular) buildings bearing the DCA insignia, from further plan review by local code enforcing agencies. Rule 913-1, FAC; and the Florida Building Code (FBC) do not require original signed and sealed plans for manufactured (modular) buildings to be submitted to local jurisdictions to obtain a building permit. The insignia issued by this Department attests that the plans have been reviewed and the buildings inspected by a state approved Third Party Agency and found compliant with the FBC. However, any code requirements not completed at the factory are considered site related and are subject to local plan review and inspection in accordance with the FBC and local requirements. Signing and sealing of these plans should follow local procedures. All site -related installation requirements (e.g., foundation, electrical hook-up, plumbing,,etc.,) are specifically and entirely reserved to the local authority having jurisdiction, who may require signed and sealed plans for applicable items. The State of Florida Manufactured (Modular) Buildings Program requires its approved Third Party Agencies to maintain a set of signed and sealed plans, (either hardcopy or electronic) that have been . reviewed and approved by a Florida licensed design professional or Modular Plans Reviewer. Inspection reports conducted at the manufacturing facility by Florida licensed design professionals or Modular Inspectors are also required to be on file. Local jurisdictions may require copies of the approved plans with the permit application or may rely on the plans on file at www.floridabuilding.org. For additional information, please contact Michael Ashworth at 850-922-6075 or E-mail: michael.ashworth@dca.state.fl.us. cc: I. Jones Files 2555 SHUMARD OAK BOULEVARD • TALLAHASSEE, FLORIDA 32399-2100 Phone: 850.488.8466/Suncom 278.8466 FAX: 850.921.0781/Suncom 291.0781 • Internet address: http://www.dca.state.fi.us CRITICAL STATE CONCERN FIELD OFFICE COMMUNITY PLANNING EMERGENCY MANAGEMENT HOUSING 3 COMMUNITY DEVELOPMENT 2796 Overseas Highway, Suite 212 2555 Shumard Oak Boulevard 2555 Shumard Oak Boulevard 2555 Shumard Oak Boulevard Marathon, FL 33050-2227 Tallahassee, FL 32399 2100 Tallahassee, FL 323M2100 Tallahassee, FL 32399-2100 • (305) 289-2402 (B50) 488.2356 (850) 413-9969 (850) 488-7956 r PRODUCT APPROVAL SPECIFICATION SHEET -150 mph - 35' MRH - Exp. C. As required by Florida statute 553.842 and Florida Administrative Code 9B-72, please provide the information and approval numbers on the building components listed below if they will be utilized on the construction project for which you are applying for a building permit. We recommend you contact your local product supplies should you not know the product approval number for any of the applicable listed products. Category/Subcategory Manufacturer Product Description Approval Number(s) 1. EXTERIOR DOORS A. SWINGING Dunbarton In -swing Exterior Door FL8172-R3 (int. zone only) B. SLIDING C. SECTIONAL D. ROLL UP E. AUTOMATIC F. OTHER 2. WINDOWS A. SINGLE HUNG Kinro 4700 Series Windows FL12053.1 B: HORIZONTAL SLIDER C. CASEMENT D. DOUBLE HUND E. FIXED APPRUVED BY G. PASS THROUGH 11 /10/09 H.PROJECTED INC. 1. MULLION approve any deviation or tlevlatlons from fhe requirements of applicable State Laws. J. WIND BREAKER K. DUAL ACTION L. OTHER 3. PANEL WALL A. SIDING Style Crest Vinyl Siding FL12231 B. SOFFITS James Hardie Soffit FL889-R4 C. EIFS Category/ Subcategory Manufacturer Product Description Approval Number(s) D.STOREFRONTS E. CURTAIN WALLS F. WALL LOUVER G. GLASS BLOCK H.MEMBRANE (.GREENHOUSE J. OTHER 4. ROOFING PRODUCTS A. ASPHALT SHINGLES GAF Owens Corning Shingles Shingles FL10124-R1 FL10674-R1 B. UNDERLAYMENTS Johns Manville CertainTeed Corp. TAMKO Black Warrior Roofing Ice & Watergard Wintergaurd TW Underlayment Underlayment FL5307-R1 FL3455-R2 FL3664-R3 FL2077-R2 C. ROOFING FASTENERS D. METAL ROOFING E. WOOD SHINGLES /SHAKES F. ROOFING TILES APPROVED BY G. ROOFING INSULATION ::=INC. 11/10/09 H. WATERPROOFING .l. BUILT UP ROOFING ROOF SYSTEMS 0 appmvo om/ devlatlon or davlatlotu hom iha mqulmmeaty of appfl abl, stale Law,. J. MOCIFIED BITUMEN K. SINGLE PLY ROOF SYSTEM L. ROOFING SLATE M. CEMENTS/ADHESIVES COATINGS Certainteed Corp -Roofing Plastic Roof Cement-5 gal. FL490-R2 Category/ Subcategory Manufacturer Product Description Approval Number(s) . N. LIQUID APPLIED ROOF SYSTEMS O. ROOF TILE ADHESIVE P. SPRAY APPLIED POLYURETHANE ROOF Q. OTHER 5.SHUTTERS Arrmtjvr-Lj by A. ACCORDIAN m 11 /10/ 9 B. BAHAMA f % C. STORM PANELS Approval of this document does not autho ■ ize or D. COLONIAL requirements of applicable State Laws. E. ROLL -UP F. EQUIPMENT G. OTHERS 6. SKYLIGHTS A. SKYLIGHT B. OTHER 7.STRUCTURAL COMPONENTS A. WOOD CONNECTORS/ANCHORS J-Mark Inc. MasterCraft Engineering Metal connector straps (22 ga straps and 0.035 metal straps) 5481 MH Strap 5483 MH Strap Local approval — NTA JH070804-10 FL9159.1 FL9159.2 B. TRUSS PLATES MiTek 16 ga truss connector plates FL2197-R1 C. ENGINEERED LUMBER GP GP -Lam FL2023-R2 D. RAILING E. COOLERS -FREEZERS Category/ Subcategory Manufacturer Product Description Approval Number(s) F.CONCRETE ADMIXTURES G. MATERIAL H. INSULATION FORMS I. PLASTICS J. DECK -ROOF K. WALL L. SHEDS M. OTHER. 8. NEW EXTERIOR ENVELOPE PRODUCTS A. B. Product Approval for all "site installed items" are on -site, by others and are not supplied by Jacobsen Homes. APPROVED BY 00orpi 11/10/09 INC. Approval of this document does not authorize or approve any deviation or deviations from the requirements of applicable State Laws. • Florida Building Code Onli�,c:> Pagel of 3 AN tf 6nlitv Affairs. BCIS Home i, Log In I User Registration I Hot Topics 1, Submit Surcharge I Stats & Facts i. Publications I FBC Staff I BCIS Site Map SI Links Search 11 i. Product Approval 9�c R USER: Public User - APPROVED BY Product Anoroval Menu > Product or Application Search > Application U > Application Detail �^ FL # FL2025-R2 11 /10/09 Application Type Affirmation ' ■ Code Version 2007 INIA Application Status Approved Approval of this document does not authorize or Comments approve any deviation or deviations from the Archived {p �9111 � m. - l I _ requirements of applicable State Laws. Product Manufacturer Hy-Lite Products Inc. Address/Phone/Email 3000 East Johnson Ave Pensacola, FL 32514 (850)473-0555 Ext- steve(e�usblockwindows.com Authorized Signature Steve Beck stevet@usblockwindows.com Technical Representative Ron Cook Address/Phone/Email 101 California Ave. Beaumont, CA 92223 (800)827-3691 Ext3281 ron cookCp hy-lite.com Quality Assurance Representative Tracy Avila Address/Phone/Email 101 California Beaumont, CA 92223 (800) 827-3691 tracy avila )hy-lite.com Category Windows Subcategory Fixed Compliance Method Certification Mark or Listing Certification Agency American Architectural Manufacturers Association Validated By Referenced Standard and Year (of Standard) Standard Year AAMA / NWWDA-101/ I.S 2-97 1997 CAWM 301-90 Forced Entry 1997 Equivalence of Product Standards Certified By r I affirm that there are no changes in the new Florida Building Code which affect my product(s) and my product(s) are in compliance with the new Florida y Building Code. ho://floridabuilding.org_/12 /pr app dtl.aspx?param=wGEVXQwtDgsUTth8cOKZcOtmOt)... 10/5/2009 Florida Building Code Online Page 2 of 3 Documentation from approved Evaluation or Validation Entity r Yes O No Q N/A Product Approval Method Method 1 Option A Date Submitted OS/01/2009 Date Validated 05/01/2009 Date Pending FBC Approval Date Approved 06/02/2009 APPROVED BY 0000 11/10/09 Ni INC. Approvd W. document dem net nutherim m Approve..y devletl- a dMdl.. frore the req'Im— of app1lceh1. SW. Lowe. Summary of Products FL # IlModel. Number or Name Description 2025.1 600/800 Aluminum w/ 3x6 3x8 Blocks Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL2025 R2 C CAC aama labels2.odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A Design Pressure: N/A Installation Instructions Other: 600/800 98x98 F-C30/ 74x74 F-HC40 / SOx50 F-1 FL2025 R2 II 600 800.odf HC80/ 26x82 F-C80 625/825 74x74 F-C35/ 50x50 F- Verified By: American Architectural Manufacturers C80/ 26x82 F-C80 Low Profile Builders Series 77x77 F- Association HC40/ 52x52 F-HC70/ 31x87 F-C80 Glass Block Series Created by Independent Third Party: Alum. 57x57 F-LC50/ Vinyl 57x57 F-LC80 Prestige Fixed Evaluation Reports Window 79x79 F-C35/ 55x55 F-C80/ 31x87 F-C80 Created by Independent Third Party: 2025.2 625/825 Aluminum w/ 2x6 2x8 Blocks Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL2025 R2 C CAC aama labels2.odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A Design Pressure: N/A Installation Instructions Other: 600/800 98x98 F-C30/ 74x74 F-HC40 / 5Ox50 F- FL2025 R2 II 625 825.odf HC80/ 26x82 F-C80 625/825 74x74 F-C35/ 50x5O F- Verified By: American Architectural Manufacturers C80/ 26x82 F-C80 Low Profile Builders Series 77x77 F- Association HC40/ 52x52 F-HC70/ 31x87 F-C80 Glass Block Series Created by Independent Third Party: Alum. 57x57 F-LC50/ Vinyl 57x57 F-LC80 Prestige Fixed Evaluation Reports Window 7909 F-C35/ 55x55 F-C80/ 31x87 F-C80 I Created by Independent Third Party: 2025.3 IlGlass Block Series Aluminum w/ 2x8 Glass Block Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL2025 R2 C CAC aama labels2.odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A Design Pressure: N/A Installation Instructions Other: 600/800 98x98 F-C30/ 74x74 F-HC40 / 50x50 F- FL2025 R2 II Glass Block Assemblv.odf HC80/ 26x82 F-C80 625/825 74x74 F-C35/ 50x50 F- Verified By: American Architectural Manufacturers C80/ 26x82 F-C80 Low Profile Builders Series 77x77 F- Association HC40/ 52x52 F-HC70/ 31x87 F-C80 Glass Block Series Created by Independent Third Party: Alum. 57x57 F-LC50/ Vinyl 57x57 F-LC80 Prestige Fixed Evaluation Reports Window 79x79 F-C35/ 55x55 F-C80/ 31x87 F-C80 Created by Independent Third Party: 2025.4 JlGlass Block Series JIVinyl w/ 2x8 Glass Block Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL2025 R2 C CAC vinyl glass label.odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A Design Pressure: N/A Installation Instructions Other: 600/800 98x98 F-C30/ 74x74 F-HC40 / 5Ox50 F- FL2025 R2 II vinyl alass.pdf HC80/ 26x82 F-C80 625/825 74x74 F-C35/ 5Ox50 F- Verified By: American Architectural Manufacturers C80/ 26x82 F-C80 Low Profile Builders Series 77x77 F- Association HC40/ 52x52 F-HC70/ 31x87 F-C80 Glass Block Series Created by Independent Third Party: Alum. 57x57 F-LC50/ Vinyl 57x57 F-LC80 Prestige Fixed Evaluation Reports Window 7909 F-C35/ 55x55 F-C80/ 31x87 F-C80 Created by Independent Third Party: 2025.5 Low Profile Builders Series IlVinyl w/ 2x6 2x8 Blocks Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL2025 R2 C CAC aama labels2.odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A Design Pressure: N/A Installation Instructions Other: 600/800 98x98 F-C30/ 74x74 F-HC40 / 5Ox50 F- FL2025 R2 II Low Profile builder series.odf HC80/ 26x82 F-C80 625/825 74x74 F-C35/ 50x5O F- Verified By: American Architectural Manufacturers hU://floridabuilding_org/nrl-�-,°d)n dtl.aspx?param=wGEVXnwtDgst- ,cOKZcOtmOn... 10/5/2009 t t Florida Building Code 011h C Page 3 of 3 d C80/ 26x82 F-C80 Low Profile Builders Series 77x77 F- HC40/ 52x52 F-HC70/ 31x87 F-C80 Glass Block Series Alum. 57x57 F-LC50/ Vinyl 57x57 F-LC80 Prestige Fixed, Window 7909 F-C35/ 55x55 F-C80/ 31x87 F-C80 Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 2025.E JlPrestige Fixed Window JIVinyl w/ 2x6 2x8 Blocks Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL2025 R2 C CAC aama Iabels2.13df Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A Design Pressure: N/A Installation Instructions Other: 600/800 98x98 F-C30/ 74x74 F-HC40 / 50x50 F- FL2025 R2 II Prestige vinvl.Ddf HC80/ 26x82 F-C80 625/825 74x74 F-C35/ 50x50 F- Verified By: American Architectural Manufacturers C80/ 26x82 F-C80 Low Profile Builders Series 77x77 F- Association HC40/ 52x52 F-HC70/ 31x87 F-C80 Glass Block Series Created by Independent Third Party: Alum. 57x57 F-LC50/ Vinyl 57x57 F-LC80 Prestige Fixed Evaluation Reports Window 7909 F-C35/ 55x55 F-C80/ 31x87 F-C80 Created by Independent Third Party: Back Next DMA Administration Department o/ Community Affairs Florida Building Code Online Codes and Standards 2555 Shumard Oak Boulevard Tallahassee, Florida 32399-2100 (850) 487-1824, Fax (850) 414-8436 © 2000-2005 The State of Florida. All rights reserved. Copyright and Disclaimer Product Approval Accepts: APPROVED BY IN7A11/10l09 INC. Approval of1h1adocumentdoesnot ea .A ar approve any de11atl-.1 de M—hom the requirements al apPileable store law.. hq://floridabuilding_org_/pr/pr app dtl.aspx?param=wGEVXQwtDq.sUTth8cOKZcOt pOp... 10/5/2009 Florida Building Code Online Page 1 of 2 ibmit Surcharge I Stats & Facts ; Publications I FBC Staff I BCIS Site Map �i Links I Search j ENWAUMMProduct Aooroval Menu > Product or Aoolication Search > Aoolication List > Application Detail FL # FL2865-R3 APPROVED BY + Application Type Revision 000 ON ` Code Version 2007 Application Status Approved 11/10/09 Comments I Archived IQ ■ Approval of this document does not authorize or Product Manufacturer Kinro, Inc approve any deviation or deviations from the requirements of applicable State Laws. .Address/Phone/Email 500 Airport Drive Mansfield, TX 76063 (817)473-4421 Ext117 ddewey0kinro.net Authorized Signature Kinard Mike mkinard(a)kinro.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Certification Agency Validated By Exterior Doors Sliding Exterior Door Assemblies Certification Mark or Listing American Architectural Manufacturers Association American Architectural Manufacturers Association Referenced Standard and Year (of Standard) Standard AAMA/WDMA/CSA 101/I.S.2/A440 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 01/22/2009 Date Validated 04/27/2009 Date Pending FBC Approval 05/04/2009 Date Approved 06/09/2009 Year 2005 ht ://floridabuildin or / rr � jp dtl.as x? aram=wGEVXOwtD s°r �" Q6%2EE c3... 10/5/2009 � �� ." � � , F_ P P � � Florida Building Code Onli :;- Page 2 of 2 M Summary of Products FL # Model, Number or Name IlDescriition 2865.1 1600 SGD 96x80, Vinyl, SGD, IG, 1/8 tempered Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL2865 R3 C CAC KIN 1600 R35 96x80.Odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 09/14/2009 Design Pressure: +35/-35 Installation Instructions Other: FL2865 R3 II Window Installation Florida v032009.od Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 2865.2 1600 SGD--------7172x8O, Vinyl, SGD, IG, 1/8 tempered Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL2865 R3 C CAC KIN 1600 R40 72x80.Ddf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 10/22/2011 Design Pressure: +40/-50 Installation Instructions Other: FL2865 R3 II Window Installation Florida v032009.Dd Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Back Next DCA Administration Department of Community Affairs Florida Building Code online Codes and Standards 2555 Shumard Oak Boulevard Tallahassee, Florida 32399-2100 (850) 487-1824, Fax (850) 414-8436 © 2000-2005 The State of Florida. All rights reserved. Copyright and Disclaimer Product Approval Accepts: bby MoVRF APPROVED BY IN11 /10/09 174 INC. Approval of this document does not authorize or approve any deviation or deviations from the requirements of applicable State Laws. htip•//floridabuilding org//p /pr apt dtl aspx?paramwGEVXQwtDgsD/`2bYQ6`/`2fEgpc3... 10/5/2009 39 St. Lucie County Wind Speed Lines APPROVED N W E Approval of approve net 5 reymremem St. Lucie County Wind Speed Line Description 130 MPH Wind Speed Line: Starting at the intersection of 1-95 and county boundary with Indian River County, south on I-95 to intersection with C-25 Canal, then west along the C-25 Canal to the intersection with the Florida Turnpike then south on the Florida Turnpike to the intersection with I-95, then south on I-95 to the county boundary with Martin County. 140 MPH Wind Speed Line: Starting at the intersection of US 1 and county boundary with Indian River County, south on US 1 to the intersection with Prima Vista Boulevard, then west on Prima Vista Boulevard to the intersection with the North Fork of the St. Lucie River, then south and southeasterly on the North Fork of the St. Lucie River to the county boundary with Martin County. Description taken from Ordinance 01-003, Exhibit A, Basic Wind Speed Zones, St. Lucie County. <Ordinance Adopted December 18, 2001; information firmed by St. Lucie County Building Department 5 2.5 0 1 St. Lucie County Wind Speed Lines ® St. Lucie County Wind Speed Lines — Major Roads St. Lucie River 0 County Boundary 5 Mile B 0 Prepared by the GeoPlan Center, University of Florida s for the Florida Department of Community Affairs, Codes and Standards Mftian. June 2007. Source: St. Lucie County Building Department, 07/0712007 Base Layer Source: Florida Geographic Data Library Job — Truss Truss Type City Ply Jacobsen Homes 216 50653 •M573001 MONO TRUSS 1 1 36 x 141 x 4 _ Replaces MMP06401 - A Universal Fores( Products Iric., Grand Rapids, MI 49525, Mike Patten ­ ' 7.050 s May 22 2008 MiTek Industries, Inc. Mon Feb 02 06:28:23 2009 0-10-0 4-2-2 APPROVED BY IN11 /10/09 INC. Approval of this doeurnent does not auNoriza or . approve any d—lation or devlatlons from Optional 0-10-0Overhang requirement, otappli-bl,State Laws. and Connection (by others) 3x4 See req'd connection 3 forces below --- �—'� - J" 2.72 V2 , L 3x4 = 0-10-0 Plate Offsets X,Y):._[2:C LOADING (psf) TCLL 20.0 (Ground Snow=20.0) TCDL 10.0 BCLL 0.0 BCDL 10.0 1x3 II SPACING 1-4-0 CSI Plates Increase 1.15 TC 0.67 Lumber Increase 1.15 BC 0.37 Rep Stress Incr YES WB 0.57 Code IBC2006/TPI2002 (Matrix) 3x4 11-9-0 DEFL in (loc) I/deft L/d Vert(LL) 0.15 7-8 >907 240 Vert(TL) 0.12 778 >999 180 Horz(TL) -0.03 6 n/a n/a 3x4 PLATES GRIP MT20 1971144 Weight: 27 lb LUMBER BRACING TOP CHORD 2 X 3 SPF No.2 TOP CHORD Structural wood sheathing directly applied or 4-6-12 oc BOT CHORD 2 X 3 SPF No.2 purl ins, except end verticals. WEBS 2 X 2 SPF Stud *Except* BOT CHORD Rigid ceiling directly applied or 4-0-14 oc bracing. W5: 2 X 3 SPF No.2 REACTIONS (lb/size) 2=303/0-3-8, 6=266/Mechanical FORCES (lb) - Maximum Compression/Maximum Tension Max Horz 2=234(LC 7) TOP CHORD 1-2=0/12, 2-3=-914/1138, 3-9=-514/621, Max Uplift2=-477(LC 7), 6=-410(LC 7) 4-9=-4771627, 4-5=-44/0, 5-6=-88/159 Max Grav 2=400(LC 18), 6=342(LC 17) BOT CHORD 2-8=-1329/881, 7-8=-1325/879, 6-7=7733/479 WEBS 3-8=-25/111, 4-7=-158/179, 3-7=-415/614, 4-6=-517/792 REQUIRED FIELD JOINT CONNECTIONS - Maximum Compression (lb)/ Maximum Tension (lb)/ Maximum Shear (lb)/ Maximum Moment (lb -in) 2=0/32/137/848 NOTES' 1) Wind: ASCE 7-05; 150mph; TCDL=6.Opsf; BCDL=3.Opsf, h=30ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone;C-C for. members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-05; Pg=20.0 psf (ground snow); Ps=20.0 psf (roof snow); Category II; Exp C; Partially Exp.; Ct=1.1; IBC 1608.3 minimum flat roof snow load governs. ,`,�0 P. � � it 3) Roof design snow load has been reduced to account for slope. +0 ...... •, 0 .. ,I 4) Unbalanced snow loads have been considered for this design. +w'' .•'� C, $ `' .0 cif 5) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non -concurrent with other live loads. No 57289 6) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. w 8) All additional member connections shall be provided by others for forces as indicated. : `Ar�: i±• �{ -�+ ilm((�,�i d � 9) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 :� • Ilk. ttl t8. T.'1• ty1,91 r llev�� . t tall by 2-0-0 wide will fit between the bottom chord and any other members. �,, 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 477 lb uplift at joint 2 ri417W4 ,�and 410 Ib uplift at joint 6.11) This truss is designed in accordance with the 2006 International Building Code section 2306.1 and referencedltlltl�� standard ANSI/TPI 1. 12) This truss has been designed in accordance with the 2006 IBC Sec 2303.4.2, 2006 IRC Sec802.10.2 February 2, 2009 13) This truss has been designed to meet the 2003 IBC Section 2308.10.7.1; 2003 IRC R802.10.2 A WARNING - Verify design parameters. and READ NOTES Universal Forest Products, Inc, 2801 EAST BELTLINE RD, NE PHONE (616)-364-6151 FAX (616)-365-0060 GRAND RAPIDS, MI 49525 This building component has only been designed for the loads noted on this drawing. Construction and lifting forces have not been considered. The builder is responsible for lifting methods and system design. Builder responsibilities are defined under section 2.3 of TPI1-2002. This design Is based only upon parameters shown, and is for an Individual building component to be installed and loaded vertically. Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer. Bracing shown is for lateral support of Individual web members only. Additional temporary bracing to insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication,quality, control, storage, delivery, erection and bracing, consult BCSI 1-03 from the Wood Truss Council of America and Truss Plate Institute Recommendation available from WTCA, 6300 Enle nrp 'se LN, Madison, WI 53719 J:\support\MltekSupp\templates\ufp tpe ©cam right 2008 by: Universal Forest Products, Inc__ FORM 1100A-08 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CO,t4W AON Florida Department of Community Affairs Residential Perform•'��►'i?�o%, Project Name: Mod-464 Street: 808 Osprey Ct. City, State, Zip: Ft. Pierce, FL, 34949- Builder Name: Jacobsen Homes = * •• Permit Office: ' Permit Number: Owner: Beverly Chesanek Jurisdiction: y % E .� Design Location: FL, Fort Pierce ��,T�• .�� Q P,.'�=�: 1. New construction or existing New (From Plans) 9. Wall Types �iptiff A t1l R=1g!� t t r132@.Df/6/2002. Single family or multiple family Single-family a. Frame -Wood, Exterior b. N/A R= ft2 .3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 5. Is this a worst case? Yes 10. Ceiling Types Insulation Area 6. Conditioned floor area (ft2) 1131 a. Under Attic (Vented) R=30.0 1131.00 ftz b. WA R= ft2 7. Windows Description Area c. N/A R= ft2 a. U-Factor: Dbl, U=0.35 223.85 ft2 SHGC: SHGC=0.30 11. Ducts a. Sup: Attic Ret: Exterior AH: Exterior Sup. R= 6, 226.2 ft2 b. U-Factor: N/A ft2 SHGC: 12. Cooling systems c. U-Factor: N/A ft2 a. Central Unit Cap: 18.1 kBtu/hr 'G SHGC: SEER: 13 d. U-Factor: N/A ft2 13. Heating systems SHGC: a. Electric Heat Pump Cap: 15.5 kBtu/hr ,gip e. U-Factor: N/A ft2 HSPF: 7.7 �F SHGC: - 14. Hot water systems 8. Floor Types Insulation Area a. Electric Cap: 30 gallons a. Raised Floor R=22.0 1131.00 ft2 EF: 0.93 b. N/A R= ft2 b. Conservation features c. N/A R= ft2 None 15. Credits Pstat Total As -Built Modified Loads: 27.74 C ASS Glass/Floor Area: 0.198 . Total Baseline Loads: 34.90 _ PASS I hereby certify that the plans and specifications covered by Review of the plans and Og'T SrT� this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance V' �i� with the Florida Energy Code. +nn,• ''�� ; ="°:�` PREPARED BY: efor on is4e�f S`� DATE: �.P,,� IUD-46 PL ItWj BRwith *. I hereby certi th building as designed, is in compliance fY � g Florida St tes. y+4 APPRO D BY WILLIAM TE R with the Florid ne�cgy' d OWNER/AGE B L IN FFLC DATE: �1=S—� - �� �\ ►v11A�.)u��te. � �s P.�b '' REQUIRES INSTALLATION ON -SITE, BY OTHERS, howe— is ltis�qllecL oh -�D 51T\ nfj 11/5/2009 11:32 AMC CVA S Irk, G 1" �EnergyGauge® USA - FlaRes2008 Page 1 of 6 �1 PROJECT Title: Mod-464 Bedrooms: .2 Adress Type: Street Address Building Type: FLAsBuilt Bathrooms: 0 Lot # Owner: Beverly Chesanek Conditioned Area: 1131 SubDivision: # of Units: 1 Total Stories: 1 PlatBook: Builder Name: Jacobsen Homes Worst Case: Yes Street: 808 Osprey Ct. Permit Office: Rotate Angle: 315 County: St. Lucie Jurisdiction: Cross Ventilation: City, State, Zip: Ft. Pierce, Family Type: Single-family Whole House Fan: FL, 34949- New/Existing: New (From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.6 % 2.5 % Winter Summer Degree Days Moisture Range FL; Fort Pierce FL ST LUCIE_CO INTL 2 39 90 75 70 722 62 Low FLOORS # Floor Type R-Value Area Tile Wood Carpet _ 1 Raised Floor 1131 ft2 22 0 0 1 ROOF Roof Gable Roof Solar Deck # Type Materials Area Area Color Absor. Tested Insul. Pitch 1 Gable or shed Composition shingles 1192 ft2 188 ft2 Dark 0.96 No 0 18.4 deg ATTIC RBS IRCC V # Type Ventilation Vent Ratio (1 in) Area 1 Full attic Vented 300 1131 ft2 N N CEILING # Ceiling Type R-Value Area Framing Frac Truss Type 1 Under Attic (Vented) 30 1131 ft2 0.09 Wood WALLS Cavity Sheathing Framing Solar # Ornt Adjacent To Wall Type R-Value Area R-Value Fraction Absor: - 1 N. Exterior Frame - Wood 19 465 ft2 0.23 0.75 2 W Exterior Frame - Wood 19 198 ft2 0.23 0.75 3 S Exterior Frame - Wood 19 465 ft2 0.23 0.75 4 E Exterior. Frame -Wood 19 198 ft2 0.23 0.75 APPROVED BY IN11 /10/09 7ri I•NC. Approval of this document does not authorize or approve any deviation or deviations from the requirements of applicable State Laws. 11/5/2009 11:32 AM EnergyGauge® USA - FlaRes2008 Page 2 of 5 DOORS # Ornt Door Type Storms U-Value Area 1 N Insulated None 0.29 21.64 ft2 WINDOWS Window orientation below is as entered. Actual orientation is modified by rotate angle shown in 'Project' section above. Overhang # Ornt Frame Panes NFRC U-Factor 'SHGC Storms Area Depth Separation Int Shade Screening 1 N Vinyl Low-E Double Yes 0.35 0.3 N 62.5 ft2 0 ft 9 in 0 ft 26 in HERS 2006 None 2 N Vinyl Low-E Double Yes 0.35 0.3 N 11.25 ft2 0 ft 9 in 0 ft 4.5 in HERS 2006 None, 3 N Vinyl Low-E Double Yes 0.35 0.3 N 5.5 ft2 0 ft 31.5 i 0 ft 26 in HERS 2006 None 4 N Vinyl Low-E Double Yes. 0.35 0.3 N 5.7 ft2 0 ft 31.5 i 0 ft 26 in HERS 2006 None 5 W Vinyl Low-E Double Yes 0.35 0.3 N 12.5 ft2 0 ft 44 in 0 ft 18 in HERS 2006 None 6 W Vinyl Low-E Double Yes 0.35 0.3 N 15 ft2 Oft 49 in 0 ft 4.5 in HERS 2006 None 7 W Vinyl Low-E Double Yes 0.35 0.3 N 11.67 ft2 0 ft 54 in 0 ft 4.5 in HERS 2006 None 8 S Vinyl Low-E Double Yes 0.35 0.3 N 15 ft2 0 ft 26 in 0 ft 8 in HERS 2006 None 9 S Vinyl Low-E Double Yes 0.35 0.3 N 10 ft2 0 ft 26 in 0 ft 8 in HERS 2006 None 10 E Vinyl Low-E Double Yes 0.35 0.3 N 43.23 ft2 0 ft 52 in 0 It 13.51 HERS 2006 None 11 E Vinyl Low-E Double Yes 0.35 0.3 N 6.5 ft2 0 ft 34 in 0 ft 13.5 i HERS 2006 None 12 E Vinyl Low-E Double Yes 0.35 0.3 N 12.5 ft2 0 It 39 in 0 ft 13.5 i HERS 2006 None 13 E Vinyl Low-E Double Yes 0.35 0.3 N 12.5 ft2 0 ft 47 in 0 ft 13.51 HERS 2006 None INFILTRATION & VENTING / --- Forced Ventilation ---- Run Time Fan v Method SLA CFM 50 ACH 50 ELA EgLA Supply CFM Exhaust CFM Fraction Watts Default 0.00036 1068 6.30 58.6 110.3 0 cfm 0 cfm 0 0 REQUIRES INSTALLATION ON -SITE, EV OTHERS. COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Ductless 1 Central Unit Single Package SEER: 13 16 kBtu/hr 480 cfm 0.75 False *REQUIRES INSTALLATION ON -SITE, ICY OTHERS, HEATING SYSTEM # System Type Subtype Efficiency Capacity Ductless _ 1 Electric Heat Pump None HSPF: 7.7 15.5 kBtu/hr False HOT WATER SYSTEM # System Type EF Cap Use SetPnt Conservation _ 1 Electric 0.93 30 gal 50 gal 120 deg None APPROVED BY ON11/10/09 INC. Approval of this document does not authorize or approve any deviation or deviations from the requirements of applicable State Laws. 11/5/2009 11:32 AM EnergyGauge® USA - FlaRes2008 Page 3 of 5 SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS ---- Supply ---- — - Return ---- Air Percent # Location R-Value Area Location Area Leakage Type Handler CFM 25 Leakage QN RLF 1 Attic 6 226.2 ft Exterior 56.55 ft Default Leakage Exterior TEMPERATURES REQUIRES Programable Thermostat: Y Ceiling Fans: Cooling [X] Jan [X] Feb Mar [X] Apr [X] May [X] Jun [X] Jul [X] Aug Sep [X] Oct [X]Nov Dec Heating X Jan X Feb XMarXApr r X May X Jun X Jul [IX]] Aug IX Sep Xj X Oct X Nov DeVenting ri X Jan X Feb X Mar X Apr X May X Jun X Jul X Aug X Sep X Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM. 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68. 68 68 68 68 68 68 68 68 68 66 66 APPROVED BY 11 /10/09 INIP11 Approval of this document does not authorize or approve any deviation or deviations from the requirements of applicable State Laws. 11l5l2009 11:32 AM EnergyGauge® USA - FlaRes2008 Page 4 of 5 APPROVED BY FORM 1100A-08 IN 174 1 /10/09 Code.Compliance Cheklist INC. Approver or rM .Ic .1nr aoee nor ft.b ze or epprova eny aef Ppll b. S.. ne from Me Residential Whole Building Performance Method A - Details ""nenfepp cabeSeaLewe. ADDRESS: 808 Osprey Ct. PERMIT #: Ft. Pierce, FL, 34949- INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors N1106.AB.1.1 Maximum:.3 cfm q.ft. winow area; Z cfm/sq.ft. d /sdoor area. _ Exterior & Adjacent Walls N1106.AB.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from, and is sealed to, the foundation to the top plate. Floors N1106.AB.1.2.2 Penetrations/openings > 1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings N1106.AB.1.2.3 Between walls & ceilings; penetrations of ceiling plane to top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures N1106.AB.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC with < 2.0 cfm from conditioned space, tested. _ Multi-story Houses N 1 106.AB. 1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts N1106.AB.1.3 Exhaust fans vented to outdoors, dampers; combustion space . heaters comply with NFPA, have combustion air. nTIdFR PRFSr:RIPTIVF MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters N1112.AB.3 Comply with efficiency requirements in Table N112.ABC.3. Switch or clearly marked circuit breaker (electric) or cutoff (gas) must be External or built-in heat trap required. _provided. Swimming Pools .& Spas N1112.AB.2.3 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters.must have a minimum thermal efficiency of 78%. Heat pump pool heaters shall have a minimum COP of 4.0. Shower heads N1112.AB.2.4 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems N1110.AB All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated and installed in accordance with the criteria of Section N1110.AB. Ducts in unconditioned attics: R-6 min. insulation.. _ _ HVAC Controls N1107.AB.2 Separate readily accessible manual or automatic thermostat for each system. Insulation N1104.AB.1 Ceilings -Min. R-19. Common walls -frame R-11 or CBS R-3 both N1102.13.1.1 sides. Common ceiling & floors R-11. 11/5/2009 11:32 AM EnergyGauge® USA - F1aRes2008 Page 5 of 5 r ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 79 The lower the EnergyPerformance Index, the more efficient the home.. 1. New construction or existing New (From Plans) 2. Single family or multiple family Single-family 3. Number of units, if multiple family 1• 4. Number of Bedrooms 2 5. Is this a worst case? Yes 6. Conditioned floor area (ft2) 1131 7. Windows" Description Area a. U-Factor: Dbl, U=0.35 223.85 ft2 SHGC: SHGC=0.30 b. U-Factor. NIA ft2 SHGC: APPROVED BY c. U-Factor: N/A ft2 ~ SHGC: INIAINC. 11/10/09 d. U-Factor: NIA ft2 SHGC: e. U-Factor: N/A ft2 SHGC: 8. Floor Types Insulation Area a. Raised Floor R=22.0 1131.00 ft2 b. N/A R= ft2 c. NIA R= ft2 9. Wall Types ' Insulation Area a. Frame -Wood, Exterior R=19.0 1326.00 ft2 b. N/A R= ft2 c: N/A R= ft2 d. N/A R= ft2 10. Ceiling Types Insulation Area a. Under Attic (Vented) R=30.0 1131.00 ft2 b. NIA R= ft2 c. N/A R= ft2 11. Ducts a. Sup: Attic Ret: Exterior AH: Exterior Sup. R= 6, 226.2 ft2 12. Codiing systems a. Central Unit Cap: 18.1 kBtu/hr SEER: 13 13. Heating systems a. Electric Heat Pump Cap: 15.5 kBtu/hr 4 HSPF: 7.7 14. Hot water systems a. Electric Cap: 30 gallons EF: 0.93 b. Conservation features None 15. Credits Pstat�Ir k REQUIRES INSTALLATiON ON-MM BY ®WHEEL I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed complian res. Builder Signature. _ Date: Address of New Home: Z" I "'� • City/FL Zip: '1") ��1,. tyLp—, *Note: The home's estimated Energy Performance Index is only available through the EnergyGauge USA - FlaRes2008 computer program. This is not a Building Energy Rating. If your Index is below 100, •your home may qualify for incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at (321) 638-1492 or see the Energy Gauge web site at energygauge.com for information and a list of certified Raters. For information about Florida's Energy Efficiency Code for Building Construction, contact the **Label required by Section 13-104.4.5 of the Florida Building Code, Building, or Section B2.1.1 of Appendix G of the Florida Building Code, Residential, if not DEFAULT. EnergyGauge® USA - FlaRes2008 WORST CASE ROTATION .BUILDING ENERGY SUMMARY Beverly Chesanek Title: Mod-464 TMY City: FL_ST_LUCIE_CO_INT 808 Osprey Ct. User Elec Util: Florida Average Ft. Pierce, FL, 34949- Gas Util: Florida Average Registration #: Run bate: 11/05/2009 11:29:05 ---- Cooling ---- ---- Heating ---- HERS Rotation Energy Use Fan Energy Cost Energy Use Fan/Pump Cost Total Energy Index a -Ratio 0 1963 kWh 426 kWh $215 258 kWh 40 kWh $27 9.172 MBtu NAN 45 2030 kWh 440 kWh $223 255 kWh 39 kWh $27 9.433 MBtu NAN 90 2084 kWh 451 kWh $229 246 kWh 38 kWh $25 9.622 MBtu NAN 135 2072 kWh 449 kWh $226 244 kWh . 37 kWh $25 9.563 MBtu NAN 180 2012 kWh 437 kWh $220 240 kWh 37 kWh $25 9.303 MBtu NAN 225 2045 kWh 443 kWh $224 253 kWh 39 kWh $27 9.488 MBtu NAN 270 2040 kWh 444 kWh $224 261 kWh 40 kWh $27 9.506 MBtu NAN 315 2004 kWh 434 kWh $219 270 kWh 41 kWh $28 9.383 MBtu NAN These results represent the most recent analysis when worst case was checked. For ratings where default appliance values were not used, the energy values will represent the building used for the HERS Score and not the entered building. Select ReportslAnnual Simulation to view energy use from the current building. APPROVED BY IN11 /10/09 7rl INC. Approval of this document does not authorize or approve any deviation or deviations from the requirements of applicable State Laws. 11/6/2009 11:33 AM EnergyGauge® USA - RaRes2008 / Page 1 of 1 Florida Code Summary Report Beverly Chesanek Title: Mod-464 TMY City: FL_ST_LUCIE_CO_I 808 Osprey Ct. FLAsBuilt Elec Util: Florida Average Ft. Pierce, FL, 34949- Gas Util: Florida Average Registration #: Run Date: 11/05/2009 11:29:12 Energy Uses Baseline Home As -Built Home a -Ratio Heating 1.90 MBtu 1.06 MBtu 0.56 Cooling 10.72 MBtu 8.32 MBtu 0.78 Hot Water 7.02 MBtu 7.02 MBtu 1.00 Total 19.64 MBtu 16.40 MBtu 0.84 Building Loads Baseline Home As -Built Home a -Ratio Heating 3.74 MBtu 2.09 MBtu* 0.56 Cooling 24.63 MBtu 19.12 MBtu* 0.78 Hot Water 6.53 MBtu 6.53 MBtu* 1.00 Total 34.90 MBtu 27.74 MBtu 0.79 * normalized modified loads Glass/Floor Area: 0.198 Total As=Built Modified Loads: 27.74 PASS Total Baseline Loads: 34.90 i4 REQUIRES INSTALLATION ONdSITE9 By 01THERS 11/5/2009 11:33 AM APPROVED BY INI11/10/09 P1. INC. Approval of this document does not authorize or approve any deviation or deviations from the requirements of applicable State taws. EnergyGauge® USA - AaRes2008 / Page 1 of 1 Building Input Summary Report. PROJECT Title: Mod-464 Bedrooms: 2 Adress Type: Street Address Building Type: User Bathrooms: 0 Lot# Owner: Beverly Chesanek Conditioned Area: 1131 SubDivision: # of Units: 1 Total Stories: 1 PlatBook: Builder Name: Jacobsen Homes Worst Case: Yes Street: 808 Osprey Ct. Permit Office: Rotate Angle: 315 County: St. Lucie Jurisdiction: Cross Ventilation: City, State, Zip: Ft. Pierce , Family Type: Single-family Whole House Fan: FL, 34949- New/Existing: New (From Plans) Comment: CLIMATE Design Design Temp Int Design Temp Heating Design Daily Temp Location Tmy Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL ST LUCIE CO INTL 39 90 70 75 722 62 Low UTILITY RATES Fuel Unit APPROVED BY Utility Name Months Fixed Cost Y $/Unit Electricity kWh Florida Average 11/10/09 0 0.09 Natural Gas Therm Florida Average I N C 0 1.72 Fuel Oil Gallon � Florida Default ApP.°°°°fW,d°m—d°o°—°—fl.° L? Propane Gallon eppmve °ny deN°d°n °, devl°d°.. from IAe Florida Default �°"°"p°v°'°Ppil.w.Ste. O 1.4 SURROUNDINGS Shade Trees Adjacent Buildings Ornt Type Height Width Distance Exist Height Width Distance N None Oft Oft Oft Oft Oft Oft NE None Oft Oft Oft Oft Oft Oft E None Oft Oft Oft Oft Oft Oft SE None Oft Oft Oft Oft Oft Oft S None Oft Oft Oft Oft Oft Oft SW None Oft Oft Oft Oft Oft Oft W None Oft Oft Oft Oft Oft Oft NW None Oft Oft Oft Oft Oft Oft FLOORS # Floor Type R-Value Area Tile Wood Carpet 1 Raised Floor 22 1131 ft2 0 0 1 ROOF Roof Gable Roof Solar Deck # Type Materials Area Area Color Absor. Tested Insul. Pitch 1 Gable or shed Composition shingles 1192 ft2 188 ft2 Dark 0.96 No 0 18.4 deg ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1131 ft2 N N 11/5/2009 11:33 AM EnergyGauge® / USRFSB v2.8 Page 1 of 4 Building Input Summary Report CEILING # Ceiling Type R-Value Area Framing Fraction Truss Type _ 1 Under Attic (Vented) 30 1131 ftZ 0.09 Wood WALLS Wall orientation below is as entered. Actual orientation is modified by rotate angle shown in "Project" section above. # Ornt Adjacent To Wall Type Cavity Width R-Value Ft Height Sheathing Framing Solar In Ft In _ Area R-Value Fraction Absor. _ 1 N Exterior Frame - Wood 19 51 8 9 465 ft2 0.23 0.75 2 W Exterior Frame - Wood 19 22 9 198 ft2 0.23 0.75 3 S Exterior Frame - Wood 19 51 8 9 465 ft2 0.23 0.75 4 E Exterior Frame - Wood 19 22 9 198 ft2 0.23 0.75 DOORS Width Height # Ornt Door Type Storms U-Value Ft In _ Ft In -Area 1 N Insulated None 0.29 38 82 21.64 ft2 WINDOWS Overhang # Ornt Frame Panes NFRC U-Factor SHGC Storm Area Depth Separation Interior Shade Screening 1 N Vinyl Low-E Double Yes 0.35 0.3 N 62.5 ft2 0 ft 9 in 0 ft 26 in None Exterior 50% 2 N Vinyl Low-E Double Yes 0.35 0.3 N .11.25 ft2 0 ft 9 in 0 ft 4.5 in None Exterior 50% 3 N Vinyl Low-E Double Yes 0.35 0.3 N 5.5 ft2 0 ft 31.5 i 0 ft 26 in None Exterior 50% 4 N Vinyl Low-E. Double Yes 0.35 0.3 N 5.7 ft2 0 It 31.5 i 0 ft 26 in None Exterior 50% 5 W Vinyl Low-E Double Yes 0.35 0.3 N 12.5 ft2 0 ft 44 in 0 ft 18 in None Exterior 50% 6 W Vinyl Low-E Double Yes 0.35 0.3 N 15 ft' 0 ft 49 in 0 ft 4.5 in None Exterior 50% 7 W Vinyl Low-E Double Yes 0.35 0.3 N 11.67 ft2 0 ft 54 in 0 ft 4.5 in None Exterior 50% 8 S Vinyl Low-E Double Yes 0.35 0.3 N 15 ft' 0 ft 26 in 0 ft 8 in None Exterior 50% 9 S Vinyl Low-E Double Yes 0.35 0.3 N 10 ft2 0 ft 26 in 0 ft 8 in None Exterior 50% 10 E Vinyl Low-E Double Yes 0.35 0.3 N 43.23 ft2 0 ft 52 in 0 ft 13.5 i None Exterior 50% 11 E Vinyl Low-E Double, Yes 0.35 0.3 N 6.5 ft2 0 ft 34 in 0 ft 13.5 i None Exterior 50% 12 E Vinyl Low-E.Double Yes 0.35 0.3 N 12.5 ft2 Oft 39 in Oft 13.5 i None Exterior 50% 13 E Vinyl Low-E Double Yes 0.35 0.3 N 12.5 ft2 Oft 47 in 0 ft 13.5 i None Exterior 50% INFILTRATION & VENTING --- Forced Ventilation - -- Terrairi/Wind Method SLA CFM 50 ELA EgLA ACH ACH 50 Supply Exhaust Run Time Shielding Best Guess 0.00050 1483 81.4 153.1 0.365 8.74 0 0 0 Suburban / Suburban MASS Mass Type Area Thickness Furniture Fraction _ No Added Mass 0 ft2 0 ft 0.3 APPROVED BY N11/10/09 A INC. 11/5/2009 11:33 AM EnergyGauge® / USRFSB v2.8 Page 2 of 4 Building Input Summary Report REQUIRES INSTALLATION ON -SITE, BY OTHERS, COOLING SYSTEM . # System Type Subtype Efficiency Capacity Air Flow SHR Ductless 1 Central Unit Single Package SEER: 13 16 kBtu/hr 480 cfm 0.75 False HEATING SYSTEM #System Type Subtype Efficiency Capacity Ductless . 1 Electric Heat Pump None HSPF: 7.7 15.5 kBtu/hr False HOT WATER SYSTEM # -System Type EF Cap Use SetPnt Credits 1 Electric 0.93 30 gal 50 gal 120 deg None SOLAR HOT WATER Collector Surface Absorp. Trans Tank Collector Type Tilt Azimuth Area Loss Coef. Prod. Corr. Volume Tank Tank Heat PV U-Value Surf Area Exch Eff Pumped Pump Energy DUCTS --- Supply ---- ---- # Location R-Value Area Location Return —= Air Area Number Leakage Type Handler CFM 25 Percent Leakage QN RLF 1 Attic 6 226.2 ft2 Exterior 56.55 ft2 1 Default Leakage Exterior "REQUIRES INSTALLATION ON -SITE, BY OTHERS. TEMPERATURES Programable Thermostat: Y Cooling Jan r Feb Mar Apr Heating �XXJJan � Feb l Mar jXj Apr Venting X Jan Feb X Mar Apr Ceiling Fans: N X May X Jun X Jul JXXJ Au �Xj May LXj Jun LX� Jul Aug X May X Jun X Jul XAug ]Se ] Sep rXSep ]]OctrX [X] Oct LX Oct ]]Nov ] Nov Nov X] Dec f X1 Dec [XI Dec Thermostat Schedule: HERS 2006 Reference Schedule Type 1 2 Hours 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 PM 80 80 Cooling (WEH) AM 78 78 PM 78 78 Heating (WD) AM 66 66 PM 68 68 Heating (WEH) AM 66 66 PM 68 68 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78, 78 78 78 78 78 66 66 66 68 68 68 68 68 68 68 66 66 66 68 68 68 68 68 68 68 78 80 78 78 78 78 78 78 68 68 68 68 68 68 68 68 80 78 78 78 68 68 68 68 80 78 78 78 68 66 68 66 80 78 78 78 68 66 68 66 APPROVED BY 11 /10/09 I.Nlrl. INC. Approval of this document does not authorize or approve any deviation or deviations from the requirements of applicable State Laws. 11/5/2009 11:33 AM EnergyGauge® / USRFSB v2.8 Page 3 of 4 Building Input Summary Report APPLIANCES & LIGHTING Appliance Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Ceiling Fans (Summer) AM 0.65 0.65 0.65 0.65 0.65 0.65 0.65 0.33 0.33 0.33 0.33 0.33 % Released: 100 PM 0.33 0.33 0.33 0.33 0.33 1 0.9 0.9 0.9 0.9 0.9 0.65 Annual Use:. 0 kWh/Yr Peak Value: 0 Watts Clothes Washer AM 0.105 0.081 0.047 0.047 0.081 0.128 0.256 0.57 0.849 1 0.977 0.872 % Released: 60 PM 0.779 0.698 0.605 0.57 0.581. 0.57 0.57 0.57 0.57 0.488 0.43 0.198 Annual Use: 0 kWh/Yr Peak Value: 0 Watts Dishwasher AM 0.139 0.05 0.028 0.024 0.029 0.09 0.169 0.303 0.541 0.594 0.502 0.443 % Released: 60 PM 0.377 0.396 0.335 0.323 0.344 0.448 0.791 1 0.8 0.597 0.383 0.281 Annual Use: 0 kWh/Yr Peak Value: 0 Watts Dryer AM 0.2 0.1 0.05 0.05 0.05 0.075 0.2 0.375 0.6 0.8 0.95 1 % Released: 10 PM 0.875 0.85 0.8 0.625 0.625 0.6 0.575 0.55 0,625 0.7 0.65 0.375 Annual Use: 0 kWh/Yr Peak Value: 0 Watts Lighting AM 0.16 0.15 0.16 0.18 0.23 0.45 0.4 0.25 0.19 0.16 0.12 0.11 % Released: 90 PM 0.16 0.17 0.25 0.27 0.34 0.55 0.55 0.88 1 0.86 0.51 0.28 Annual Use: 1360 kWh/Yr Peak Value: 444 Watts Miscellaneous AM 0.48 0.47 0.47 0.47 0.47 0.47 0.64 0.71 0.67 0.61 0.55 0.53 % Released: 90 PM 0.52 0.5 0.5 0.5 0.59 0.73 0.79 0.99 1 0.96 0.77 0.55 Annual Use: 2104 kWh/Yr Peak Value: 386 Watts Pool Pump AM 0 0 0 0 0 0 0 0 0 1 1 1 % Released: 0 PM 1 1 1 1 0 0 0 0 0 0 0 0 Annual Use: 0 kWh/Yr Peak Value: 0 Watts Range AM 0.057 0.057 0.057 0.057 0.057 0.114 0.171 0.286 0.343 0.343 0.343 0.4 % Released: 100 PM 0.457 0.343 0.286 0.4 0.571 1 0.857 0.429 0.286 0.229 0.171 0.114 Annual Use: 0 kWh/Yr Peak Value: 0 Watts Refrigeration AM 0.85 0.78 0.75 0.73 0.73 0.73 0.75 0.75 0.8 0.8 0.8 0.8 % Released: 100 PM 0.88 0.85 0.85 0.83 0.88 0.95 1 0.98 0.95 0.93 0.9 0.85 Annual Use: 775 kWh/Yr Peak Value: 106 Watts Well Pump AM 0.05 0.05 0.05 0.05 0.05 0.05 0.1 0.1 0.1 0.1 0.1 0.1 % Released: 0 PM 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 Annual Use: 0 kWh/Yr Peak Value: 0 Watts APPROVED BY NrPI11 /10/09 INC. Approval of this document does not authorize or approve any deviation or deviations from the requirements of applicable State Laws. 11/5/2009 11:33 AM EnergyGauge® / USRFSB V2.8 Page 4 of 4 r - Monthly Summary Energy Use Report Beverly Chesanek Title: Mod-464 TMY City: FL_ST_LUCIE_CO_I 808 Osprey Ct. FLAsBuilt Elec URI: Florida Average Ft. Pierce, FL, 34949-. Gas Util: Florida Average Registration #: Run Date: 11/06/2009 11:29:12 End -Use Units Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Total Cooling kWh 14 25 77 95 269 303 361 373 252 158 54 23 2004 Cooling Fan kWh 3 5 17 21 59 66 79 81 54 33 11 5 434 Cooling Vent Fan kWh 0 0 0 0 0 0 0 0 0 0 0 0 0 Heating kWh 132 18 19 2 0 0 0 0 16 19 9 54 270 Heating Fan/Pump kWh 20 3 3 0 0 0 0 0 2 3 1 8 41 Heating Vent Fan kWh 0 0 0 0 0 0 0 0 0 0 0 0 0 Hot Water kWh 204 183 194 174 165 148 146 148 151 169 178 197 2057 Hot Water Pump kWh 0 0 0 0 0 0 0 0 0 0 0 0 0 Ceiling Fans kWh 0 0 0 0 0 0 0 0 0 0 0 0 0 Clothes Washer kWh 0 0 0 0 0 0 0 0 0 0 0 0 0 Dishwasher kWh 0 0 0 0 0 0 0 0 0 0 0 0 0 Dryer kWh 76 68 76 73 76 73 76 76 73 76 73 76 891 Lighting kWh 115 104 115 112 115 112 115 115 112 115 112 115 1360 Miscellaneous kWh 128 116 128 124 128 124 128 128 124 128 124 128 1608 Pool Pump kWh 0 0 0 0 0 0 0 0 0 0 0 0 0 Range kWh 38 34 38 37 38 37 38 38 37 38 37 38 447 _ Refrigerator kWh 66 59 66 64 66 64 66 66 64 66 64 66 775 Photovoltaics kWh 0 0 0 0 0 0 0 0 0 0 0 0 0 Cost $ 71 53 66 64 82 83. 90 92 80 72 60 64 880 Total kWh 9787 $880 Total Therms 0 $0 APPROVED 0or BY Total Oil Gallons 0 $0 11/10/09 Total Propane Gallons 0 $0 INC. Total PV Produced 0 $0 Approval of this document does not authorin or ' approve any devlallon or devlabons tram the requlmments of applicable State laws, . Heating Energy Use 136. 132 126 12D 112 104 96 W 60 72 04 � 54 Y 56 46 40 32 24 is 19 15 19 16, 0 0 T 0 0 '0 T- 0 1 e Jon Feb Uar Apr May Jun Jul Aug Sep Oct Nav Dec 11/5/2009 11:33 AM Cooling Energy Use aaa 361 360 336 312 303 288 269 264 240 216 192 192 Y lea 144 120 95 24 Jan Feb 6far Apr May Jun Jul EnergyGaugeO / USRFSB v2.8 252 156 23 Aug Sep Oct NOV Duo Page 1 of 1 Annual Energy Summary Beverly Chesanek Title: Mod-464 TMY City: FL_ST_LUCIE CO —I 808 Osprey Ct. FLAsBuilt Elec URI: Florida Average Ft. Pierce, FL, 34949- Gas Util: Florida Average Registration #: Run Date: 11/05/2009 11:29:12 End -Use Cooling (18.1 kBtu/hr) Cooling Fan Mechanical Vent Fan Total Cooling Heating (15.5 kBtu/hr) Heating Fan/Pump Mechanical Vent Fan Total Heating Hot Water . Hot Water Pump Total Hot Water Ceiling Fans Clothes Washer Dishwasher Dryer Lighting Miscellaneous Pool Pump Range Refrigerator Energy Consumption 2004 kWh 434 kWh 0 kWh 2438 kWh 270 kWh 41 kWh 0 kWh 311 kWh 2057 kWh 0 kWh 2067 kWh 0 kWh 0 kWh 0 kWh 891 kWh APPROVED BY 130U K V V 1 I 11/10/09 1508 kWh NOOOOA INC. 0 kWh 447 kWh 775 kWh Total (kWh) Total (Therms) Total (Oil Gallons) Total (Propane Gallons) PV Produced (kWh)" " Assumes net metering Total Cost 11/5/2009 11:33 AM 9787 kWh 0 Therms 0 Gallons 0 Gallons 0kWh EnergyGauge® USA - FIaRes2008 / Annual Cost $180 $39 $0 $219 $24 $4 .$0 $28 $185 $0 $185 $0 $0 $0 $80 $'1122 $136 $0 $40 $70 $880 $0 $0 $0 $0 $880 Page 1 of 1 K M Jacobsen Homes 600 Packard Court Safety Harbor, FL 34695 Model: MOD-464 MOD-464 Production Shearwall Summary MOD-464 Wall 1: Minimum sheathing required: 7116" APA OR TECO RATED SHEATHING 365 p.l.f. Sheathing Fastening: 15 GAUGE STAPLE - 1.875 IN. LENGTH - 3 IN. O.C. MAX. SPACING APPROVED BY Min. wall to floor/wall/ceiling fastening required: 11/10/09 ON07P 0.131"x 3 1/2" NAIL @ 3.75" O.C. MAX. ew'^. °Additionalshearwalltojoist-attachmentrequired:' (either method may be used):'° " _ •��� � �1,1vM Bracket:" SIMPSON HDU87SDS2.5 or. VAX' x0 0334'',x.18" stra ;3 ,.,"STRAPS'MINIMUM'EACHEND ,OF EACHrSHEAR SEGMENT_ 10 - 0.131" x 2" NAILS.EACH END OF'EACH STRAP or 1 '1/2" x 0.0274" x 18" strap: 8 , .:= STRAPS' MINIMUM -EACH END OF EACH SHEAR SEGMENT - • 5 . ":,- 0.131" z 2"•NAILS EACH END OF EACH,STRAP Wall 2: Minimum sheathing required: 3/8" APA OR TECO RATED SHEATHING 335 p.l.f. Sheathing Fastening: 16 GAUGE STAPLE - 1.875 IN. LENGTH - 3 IN. O.C. MAX. SPACING Min. wall to floor/wall/ceiling fastening required: 0.131" x 3 1/2" NAIL @ 3.75" O.C. MAX. ldditional�sheaiwall.to`xjoist.;attaciimeht required:' '(either method mad be.used)_. Bracket: SIMPSON HDU8-SDS2.5 or.1,1/4"x�0.0334" x 18" strap: 3 ` -STRAPS MINIMUM, EACH END OF EACH SHEAR SEGMENT ` 10, 0.131 ' x 2" NAILS. EACH END OF EACH STRAP r „` ,, ' • or 1 1/2" �x 0 0274'sx 18' strap:: ' ° Z `- $TRAPS MINIMUM EACH END OF EACH SHEAR SEGMENT 5 - 0.131" x 2" NAILS EACH END OF�EACH STRAP, Wall 3: Minimum sheathing required: 3/8" APA OR TECO RATED SHEATHING 289 p.l.f. Sheathing Fastening: 16 GAUGE STAPLE - 1.875 IN. LENGTH - 3 IN. O.C. MAX. SPACING Min. wall to floor/wall/ceiling fastening required: .0.131"x 3 1/2" NAIL @ 3.75" O.C. MAX. Additional shearwall,to.1oist attachment required: (either method maybe used) Bracket: SIMPSON HDU8-SDS2 5 or, 1%4'' x 0 0334', z"18" strep: 3 ;STRAPS`MINIMUM EACH END "OF EACH SHEAR SEGMENT'` 1.0 " - 0.131 "-x; 2" NAILS EACH END .OF EACH STRAP or. 1. 1/2" x.0.0274" x 18",strap:- 6 ,,..-STRAPSWINIMUM EACH END OF EACH SHEAR SEGMENT _5 , .;-0..131" x 2" NAILS EACH�END QF. EACH°STRAP Wall 4: Minimum sheathing required: 7/16" APA OR TECO RATED SHEATHING 188 p.l.f. Sheathing Fastening: 16 GAUGE STAPLE - 1.875 IN. LENGTH- 4 IN. O.C. MAX. SPACING Min. wall to floor/wall/ceiling fastening required: 0.131" x 3 1/2" NAIL @ 3.75" O.C. MAX. Additional shearwall fojoist`attachment re uired:` q either method ma'`be used ( y ) Bracket; SIMPSON HDU8=SDS2.5 or 1 1/4""x 0 0334",x 18",strap: ' 2 -STRAPS MINIMUM EACH END OF EACH SHEAR SEGMENT 10 = 0.131'•x,,29-NAIL'S,EACH END'OF EACH, STRAP or 1 1/2" x'0.0274" x 18" strap: 4 : STRAPS`MINIMUM,EACH END`Q EACH'SHEAR SEGMENT ` " ' •' 5 - 0.131 `x 2" NAILS EACH END OF EACH STRAP Page 1 of 2 Wall 5: 0 PIE Wall 6: 0 PIE Wall 7: 0 PIC Wall 6: 0 PIC Jacobsen Homes 600 Packard Court Production Shearwall Summary Safety Harbor, FL 34695 Model: MOD-464 MOD-464 MOD-464 WALL NOT USED WALL NOT USED WALL NOT USED WALL NOT USED APPROVED BY ON11/10/09 INC. Approval of this document does not authorize or approve any deviation or deviations from the requirements of applicable State laws. Page 2 of a � e cJer p a he l APPROVED BY ON 11 /10/09 INC. Approval of this document does not authorize or approve any deviation or deviatlons from the requirements of applicable State Laws. 20 HORIZONTI 7/16" MIN. OSB FASTENED TC 2x4 HORIZONTAL FRAMING PER STD. WALL si4rra-NwwDETAILS FASTEN EACH END OF HORIZ. 20 TO 20 WALL FRAMING (INSIDE OF OPENING) W/ (1) #80" SCREW (MINIMUM OF 8 SCREWS TOTAL) acc,eSS - lrAertbr w;rA Zone 1 SD m?1n meam Rook 49ly k r 35� 2x4 JACK (INSET 1 1/2") ON EACH SIDE OF OPENING (FASTEN W1 0.1110 Qd NAILS e la" 0 C. STANDARD OPENING FRAMING (PER OTHER DETAILS) ,,,��tttttt►►►►���� pSLG TO * No 63802 ••• *� JIL 441Al - Ile 11/6/2009 ���►►►littt��� Water Heater Panel Access Wind Speed = 150 mph Exposure = C Mean Roof Height = 35 ft Interior Wall Wind Load = 63.7 psf Width of Opening = 23 in Spacing of Framing = 24 in o/c Load Along Framing = . 127 plf * Use 2x4 SYP #3 at 24" o/c Suction Load at Each Frame = 122 Ibs/ side W Capacity of #8 x 3 screw = 338.4 Ibs/screw wind; SYP, 1.5" screw * Use (1) #8 x 3" screw at every frame/jack connection ~ Load Along Jack Stud = 127 plf Capacity of .131 pd nail = 161.6 Ibs wind, SYP Spacing of nails = 15 " o/c * Fasten Jack Stud to Jamb with .131 pd nails at 12" o/c APPROVED BY ON107 11 /10/09 INC. Approval of this document does not authorize or approve anydeviation or deviations from the requirements of applicable State Laws. ``II►111111/��� E'L G T '. �` C•ENS' •.�'. �� F •. O * : No 63802 _ r /� 4-�: � �K� Ft `. P, •'�_�. 4NALE�,C��. ���flllllll� 11 /15/2009 17 APPROVED BY IN11 /10/09 "A'I NC. Approval of Nb dacuneN ma9 rol aNMNnor avaroa•,m aniNian or aaamaoro,ma, me roaWreroew ei avvuaawe se.,aa.. Dimensional Lumber Spans Jacobsen Homes - Horizontal Framing in Water Heater Access T Load = 127 plf A TL 120 Cd = 1.6 L Load = 127 plf 0 LL 120 %%I111111111 o ♦* No 63802 *� . design • tech • inc _ - .. s ea7a,bis:a.Lsn�.a,m:E.<,urn.n� r r , M GT Al Y i S G• �� ���111111{1111 11 /6/2009 Member. in in psi psi psi in" in' x CIU Max Spans Max Span 3ft-tin • LL Max Spans Max Span 3ft-tin • LL FORM 1100A-08 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential PerfA B 'A Project Name: Mod-464 Builder Name: Jacobsen Homes NOV 10 Z099 Street: 808 Osprey Ct. Permit Office: City, State, Zip: Ft, Pierce, FL , 34949- Permit Number 00or 014 Owner. Beverly Chesanek Jurisdiction: Design Location: FL, Fort Pierce 14 INIL 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Frame -Wood, Exterior R=19.0 1326.00 fN b. NIA R= fta 3. Number of units, if multiple family 1 c. NIA R= fi' 4. Number of Bedrooms 2 d. WA R= fta 5. Is this a worst case? Yes 10. Ceiling Types Insulation Area 6. Conditioned floor area (W) 1131 a. Under Attic (Vented) R=30.0 1131.00 fta b. NIA R= fta 7. Windows Description Area c, N/A R= IF -a. U-Factor. Dbl, U=0.35 223.85 IF SHGC: SHGC=0.30 11. Ducts b. U-Factor. N/A fta a. Sup: Attic Rat Exterior AH: Exterior Sup. R= 6, 226.2 ft2 SHGC: 12. Cooling systems c. U-Factor NIA fiz a. Central Unit Cap:18.1 kBtuRrc '} G SHGC: SEER: 13 d. U-Factor: N/A fta 13. Heating systems SHGC: a. Electric Heat Pump Cap: 15.5 kBtulhr �C e. U-Factor: NIA fe HSPF:7.7 SHGC: 14. Hot water systems 8. Floor Types Insulation Area a. Electric 30 allows g a. Raised Floor R=22.0 1131.00 W ER 0.@3 b. NIA R= ffa b. Conservation features c. NIA R=- fe None 15. Credits Pstat Total As -Built Modified Loads: 27.74 c Glass/Ftoor Area: 0.198 PASS Total Baseline Loads: 34.90 I hereby certify that the plans and specifications covered by Review of the plans and C11 WE ST this- calculation are in compliance with the Florida Energy Code. specifications covered by this calculation indicates compliance , g with the Florida Energy Code. PREPARED BY: Before construction Is completed v DATE:' this building will be inspected for compliance with Section 553.908 y *. I hereby certify th ullding, es designed, is in compliance Florida Statutes. 1 with the Florid n d OWNERIAGE BUILDING OFFICIAL. DATE: - DATE: x' RMLQRES INSTALLdTfON AM-S1M BY OTHERS. �/'�t/�-C.. C��-trrict}.� Jt�W1C� -}1-� s l "S vre etr 51- E VIO 11/5/200911:32 AM C Q1i1 S 1-� � =;�EnwgyGaugeO USA - FlaRes2008 Page 1 of 5 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX' = 79 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing New (From Plans) 2. Single family or multiple family Single-family 3. Number of units, if multiple family 1 4. Number of Bedrooms 2 5. is this a worst case? Yes 6. Conditioned floor area (ft=) 1131 7. Windows" Description Area a. U-Factor. Dbl, U=0.35 223.85 ft2 SHGC: SHGC=0.30 b: U-Factor. NIA ft2 SHGC: APPROVED BY c. U-Factor. NIA fe SHGC: N 11/10/09 d. U-Factor. N/A ' N C. ft2 SHGC:cf C.60�tlCeuM�dL2a e. U-Factor. NIA � � � ft2 SHGC: 8. Floor Types Insulation Area a. Raised Floor R=22.0 1131.00 ft2 b. N/A R= ft2 c. N/A R= ft2 9. Wall Types a. Frame - Wood, Exterior b. NIA c: NIA d. NIA 10. Ceiling Types a. Under Attic (Vented) b. NIA c. NIA Insulation Area R=19.0 1326.00 ft2 R= ft2 R= ft2 R= ft2 Insulation Area R=30.0 1131.00 ftZ R= fts R= ft2 11. Ducts a. Sup: Attic Ret Exterior AH: Exterior Sup. R= 6, 226.2 ft2 12. Cooling systems a. Central Unit Cap: 18.1 kBtu/hr SEER: 13 13. Heating systems a. Electric Heat Pump 14. Hot water systems a. Electric b. Conservation features None 15. Credits Cap: 15.5 kBtulhr 4 HSPF: 7.7 9� Cap: 30 gallons EF: 0.93 Psta,vr * REWRES INSTALLATION OMM By OTIi€ & I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed gokcomplian res. Builder Signature C Via, Date: 11.-s-� Address of New Home: �. City/FL Zip: -r1T. �j UC_Q, _ *Note: The home's estimated Energy Performance Index is only available through the EnergyGauge USA - FlaRes2008 computer program. This is not a Building Energy Rating. If your Index is below 100, your home may qualify for incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at (321) 638-1492 or see the Energy Gauge web site at energygauge.com for information and a list of certified Raters. For information about Florida's Energy Efficiency Code for Building Construction, contact the **Label required by Section 13-104.4.5 of the Florida Building Code, Building, or Section B2.1.1 of Appendix G of the Florida Building Code, Residential, if not DEFAULT. EnergyGauge® USA - FlaRes2008 PROJECT Title: Mod-464 Bedrooms: .2 Adress Type: Street Address Building Type: FLAsBuiit Bathrooms: 0 Lot # Owner: Beverly Chesanek Conditioned Area: . 1131 SubDivision: # of Units: 1 Total Stories: 1 PlatBook: Builder Name: Jacobsen Homes Worst Case: Yes Street: 808 Osprey CL Permit Office: Rotate Angle: 315 County: St. Lucie Jurisdiction: Cross Ventilation: City, State, Zip., Ft. Pierce, Family Type: Single-family Whole House Fan: FL, 34949- New/Existing: New (From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL; Fort Pierce Fl, ST_LUCIE CO_INTL 2 39 90 75 70 722 62 Low FLOORS # Floor Type R-Value Area Tile Wood Carpet 1 Raised Floor 1131 f12 22 0 0 1 ROOF / Roof Gable Roof Solar Deck v # Type Materials Area Area Color Absor. Tested Insul. Pitch 1 Gable or shed Composition shingles 1192 11:2 188 ft2 Dark 0.96 No 0 18.4 deg ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1131 ft2 N N CEILING # Ceiling Type R-Value Area Framing Free Truss Type 1 Under Attic (Vented) 30 1131 f12 0.09 Wood WALLS F# Cavity Sheathing Framing. Solar Omt Adjacent To Wall Type R-Value Area R-Value Fraction Absor. 1 N. Exterior Frame - Wood 19 .465 ft2 0.23 0.75 2 W Exterior Frame - Wood 19 198 ft2 0.23 0.75 3 S Exterior Frame - Wood 19 465 ft2 0.23 0.75 4 E Exterior. Frame - Wood 19 198 ft2 0.23 0.75 APPROVED BY ON11 /10/09 INC. Approval of this document does not authorize or approve any deviation or deviations from the requirements of applicable State Laws. 11161200911:32 AM EnergyGauge® USA - FlaRes2008 Page 2 of 5 DOORS # Omt Door Type Storms U Value Area 1 N Insulated None 0.29 21.64 112 WINDOWS Window orientation below is as entered. Actual orientation is modified by rotate angle shown in "Project" section above. Overhang # Omt Frame 'Panes NFRC U-Factor 'SHGC Storms Area Depth Separation Int Shade Screening 1 N Vinyl Low-E Double Yes 0.35 0.3 N 62.5 ft2 0 ft 9 in 0 ft 261n HERS 2006 None 2 N Vinyl Low-E Double Yes 0.35 0.3 N 11.25 ft2 0 ft 9,1n 0 ft 4.51n HERS 2006 None , 3 N Vinyl Low-E Double Yes 0.35 0.3 N 5.6 ft2 0 ft 31.510 It 26 in HERS 2006 None 4 N Vinyl Low-E Double Yes 0.35 0.3 N 5.7 ft2 0 ft 31.5 i 0 ft 26 In HERS 2006 None 5 W Vinyl Low-E Double Yes 0.35 0.3 N 12.5 ft2 0 It 44 in 0 It 18 in HERS 2006 None 6 W Vinyl Low-E Double Yes 0.35 0.3 N 15 ft2 0 ft 49 in 0 ft 4.5 in HERS 2006 None 7 W Vinyl Low-E Double Yes 0.35 0.3 N 11.67 11:2 0 ft 54 in 0 ft 4.5 in HERS 2006 None 8 S Vinyl Low-E Double Yes 0.35 0.3 N 15 ft2 0 ft26 in 0 ft 8 in HERS 2006 None 9 S Vinyl Low-E Double Yes 0.35 0.3 N 10 ft2 0 ft 26 in 0 It 81n HERS 2006 None ID E Vinyl Low-E Double Yes 0.35 0.3 N 43.23 fie Oft 52 in 0 it 13.51 HERS 2006 None 11 E Vinyl Low-E Double Yes 0.35 0.3 N 6.5 ft2 0 ft 34 in Oft 13.51 HERS 2006 None 12 E Vinyl Low-E Double Yes 0.35 0.3 N 12.5 ft2 0 ft 39 in Oft 1 &51 HERS 2006 None 13 E Vinyl Low-E Double Yes 0.35 0.3 N 12.5 ft2 0 It 47 in 0 It 13.51 HERS 2006 None INFILTRATION & VENTING / - Forced Ventilation - Run Time Fan v Method SLA CFM 50 ACH 50 EIA EgLA Supply CFM Exhaust CFM Fraction Watts Default 0.00036 1068 6.30 58.6 110.3 0 elm 0 cfm 0 0 a REQUIRES INSTALLATION ON -SITE, BY OTHERS. COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Ductless 1 Central Unit Single Package SEER: 13 16 kBtu/hr 480 cfm 0.75 False REQUIRES INSTALLATIONS ON -SITE, BY OTHERS. . HEATING SYSTEM # System Type Subtype Efficiency Capacity Ductless 1 Electric Heat Pump None HSPF: 7.7 15.5 kBtu/hr False HOT WATER SYSTEM # System Type EF Cap Use SetPnt Conservation 1 Electric 0.93 30 gal 50 gal 120 deg None APPROVED BY ONrP1 11/10/09 INC. Approval of this document does not authorize or approve any deviation or deviations from the requirements of applicable State Laws. 11151200911:32 AM EnergyGauge® USA - FlaRes20D8 ' Page 3 of 6 SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / — Supply --- — Return = Air Percent V. # Location R-Value Area Location Area Leakage Type Handier CFM 25 Leakage QN RLF 1 Attic 6 226.2 ft Exterior 56.55 ft Default Leakage Exterior TEMPERATURES eS U E Programable Thermostat: Y Ceiling Fans: Cooling 1X M XI �JA Apr May RIJun Jun Jul Aug Sep NC Occtt Oct 1XI Nov Nov Dec NC Decec Venting Jan Feb Mar X� Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM, 78 - 78 78 78 78 78 78 78 80 8D 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) 78 78 78 78 78 78 78 78 78 78 78 78 PM Heating (WD) 68 68 68 68 68 66 PM 66 66 68 68 68 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 APPROVED BY 7 11 /10/09 INC. Approval of this document does not outhorlffi or approve any deviation or deviations from the requirements of applicable State Laws. 1115/2D0911:32 AM EnergyGauge® USA - FlaRes2008 Page 4 of 5 APPROVED BY 00O FORM 1100A-08 11/10/09 N INC. Code Compliance Cheklist Residential Whole Building Performance Method A - ADDRESS: 808 Osprey Ct. PERMIT #: Ft Pierce, FL, 34949- INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors N1106.AB.1.1 Maximum:.3 cfm/s .ft. window area;.5 cfm/s .ft. door area. Exterior & Adjacent Walls N1106AB.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from, and is sealed to, the foundation to the top plate. _ Floors N1106.AB.1.2.2 Penetrationstopenings > 1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings N1106.AB.1.2.3 Between walls & ceilings; penetrations of ceiling plane to top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures N1106.AB.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 112" clearance & 3" from insulation; or Type IC with < 2.0 cfm from conditioned space, tested. Multi -story Houses N1106.AB.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts N1106.AB.1.3 Exhaust fans vented to outdoors, dampers; combustion space . heaters comply with NFPA, have combustion air. OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters N1112AB.3 Comply with efficiency requirements in Table N112.ABC.3. Switch or clearly marked circuit breaker (electric) or cutoff (gas) must be rovided. External or built-in heat trap required. Swimming Pools & Spas N1112AB.2.3 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. Heat pump pool heaters shall have a minimum COP of 4.0. Shower heads N1112.AB.2.4 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems N1110.AB All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated and installed in accordance with the criteria of Section N1110.AB. Ducts in unconditioned attics: R-6 min. insulation.. HVAC Controls N1107.AB.2 Separate readily accessible manual or automatic thermostat for each system. Insulation NI 104.AB.1 Ceilings -Min. R-19. Common walls -frame R-11 or CBS R-3 both N1102.B.1.1 sides. Common ceiling & floors R-11. 11/5/2009 11:32 AM EnergyGauge® USA - FlaRes2008 Page 5 of 5 WORST CASE ROTATION - BUILDING ENERGY SUMMARY Beverly Chesanek Title: Mod464 TMY City: FL ST LUCIE CO INT 808 Osprey Ct. User Elec Util: Florida Average Ft. Pierce, FL, 34949- Gas Util: Florida Average Registration #: Run Date: 11/05/2009 11:29:05 ---- Cooling — — Heating --- HERS Rotation Energy Use Fan Energy Cost Energy Use Fan/Puma Cost Total Energy Index a -Ratio 0 1963 kWh 426 kWh $215 258 kWh 40 kWh $27 9.172 MBtu NAN 45 2030 kWh 440 kWh $223 255 kWh 39 kWh $27 9.433 MBfu NAN 90 2084 kWh 451 kWh $229 246 kWh 38 kWh $25 9.622 MBtu NAN. 135 2072 kWh 449 kWh $226 244 kWh . 37 kWh $25 9.563 MBtu NAN 180 2012 kWh 437 kWh $220 . 240 kWh 37 kWh $25 9.303 MBtu NAN 225 2045 kWh ' 443 kWh $224 253 kWh 39 kWh $27 9.488 MBtu NAN 270 2040 kWh 444 kWh $224 261 kWh 40 kWh $27 9.506 MBtu NAN 315 2004 kWh 434 kWh $219 270 kWh 41 kWh $28 9.383 MBtu NAN These results represent the most recent analysis when worst case was checked. For ratings where default appliance values were not used, the energy values will represent the building used for the HERS Score and not the entered building. Select ReportsjAnnual Simulation to view energy use from the current building. APPROVED BY 11 /10/09 NAINC. Approval of this document does not authorize or approve any deviation or deviations from the requirements of applicable State taws. 11/5/2009 11.33 AM EnergyGauge® USA - FleRes2008 / Page 1 of 1 Florida Code Summary Report Beverly Chesanek Title: Mod-464 TMY City: FL_ST LUCIE CO I 808 Osprey Ct. FLAsBuilt Elec U51: Florida Average Ft. Pierce, FL, 34949- Gas Util: Florida Average Registration #: Run Date: 11/05/2009 11:29:12 Energy Uses Baseline Home As -Built Home a -Ratio Heating . 1.90 MBtu 1.06 MBtu 0.56 Cooling 10.72 MBtu 8.32 MBtu 0.78 Hot Water 7.02 MBtu 7.02 MBtu 1.00 Total 19.64 MBtu 16.40 MBtu 0.84 Building Loads Baseline Home As -Built Home a -Ratio Heating 3.74 MBtu 2.09 MBtu* 0.56 Cooling 24.63 MBtu 19.12 MBtu* 0.78 Hot Water 6.53 MBtu 6.53 MBtu* 1.00 Total 34.90 MBtu 27.74 MBtu 0.79 * normalized modified loads Glass/Floor Area: 0.198 Total As=Built Modified Loads: 27.74 PASS Total Baseline Loads: 34.90 67 * REQUIRES INSTALLA11o" 0"M By OTIJERS. APPROVED BY 000 11/10/09 � NC. Approval of this document does not authorize or approve any deviation or deviations from the requirements of applicable State laws. 11/512009 11:33 AM EnergyGauge® USA - RaRes2008 / Page 1 of 1 Building Input' Summary Report. - PROJECT Title: Mod-464 Bedrooms: 2 Adress Type: Street Address Building Type: User Bathrooms: 0 Lot# Owner. Beverly Chesanek Conditioned Area: 1131 SubDivision: # of Units: 1 Total Stories: 1 PlatBook: Builder Name, Jacobsen Homes Worst Case: Yes Street: 808 Osprey Ct. Permit Office: Rotate Angle: 315 County: St. Lucie Jurisdiction: Cross Ventilation: City, State, Zip: Ft. Pierce, Family Type: Single-family Whole House Fan: FL, 34949- New/Existing: New (From Plans) Comment: CLIMATE Design Design Temp Int Design Temp Heating Design Daily Temp Location Tmy Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL ST LUC1E CO INTL 39 90 70 75 722 62 Low UTILITY RATES Fuel Unit APPROVED BY Utility Name Monthly Fixed Cost $/Unit Electricity kWh Florida Average 11/10/09 0 0.09 Natural Gas Therm Florida Average INC. 0 1.72 Fuel 011 Gallon Florida Default 0 1.1 Propane Gallon Florida Default 0 1.4 SURROUNDINGS Shade Trees Adjacent Buildings Omt Type Height Width Distance Exist Height Width Distance N None Oft Oft Oft Oft Oft Oft NE None Oft OR Oft Oft Oft Oft E None Oft Oft Oft Oft Oft Oft SE None 0 R 0 ft O ft O ft 0 ft O ft S None Oft 0It OR Oft Oft Oft SW None Oft Oft Oft Oft Oft Oft W None Oft Oft Oft Oft Oft Oft NW None Oft OR Oft Oft OR Oft FLOORS # Floor Type RWValue Area Tile Wood Carpet _ 1 Raised Floor 22 1131 ft2 0 0 1 ROOF Roof Gable Roof Solar Deck # Type Materials Area Area Color Absor. Tested insul. Pitch 1 Gable or shed Composition shingles 1192 ft2 188 ft2 Dark 0.96 No 0 18A d ATTIC # :Full Ventilation Vent Ratio (1 in) Area RBS IRCC 1 ttic Vented 300 1131 ft N N 11/51200911:33 AM EnergyGauge® / USRFSB v2.8 Page 1 of 4 Building Input Summery Report CEILING # Ceiling Type R-Value Area Framing Fraction Truss Type 1 Under Attic(Vented) 30 1131 ft2 0.09 .Wood WALLS Wall orientation below is as entered. Actual orientation is modified by rotate angle shown in "Project" section above. Adt'acerit ll Cavity Width Height Sheathing Framing Solar # Ornt o Wall Type R Value Ft In Ft In Area R Value Fraction Absor. 1 N Exterior Frame - Wood 19 51 8 9 465 ft2 0.23 0.75 2 W Exterior Frame - Wood 19 22 9 198 ft2 0.23 0.76 3 S Exterior Frame - Wood 19 51 8 9 465 ft2 0.23 0.75 4 E Exterior Frame - Wood 19 22 9 198 ft2 0.23 0.75 DOORS Width Height # Omt Door Type Storms U Value Ft In Ft In Area 1 N Insulated None 0.29 38 82 21.64 fF WINDOWS Overhang # Omt Frame Panes NFRC U-Factor SHGC Storm Area Depth Separation interior Shade Screening 1 N Vinyl Low-E Double Yes 0.35 . 0.3 N 62.5 ft2 0 ft 9 in 0 ff 26 in None Exterior 50% 2 N Vinyl Low-E Double Yes 0.35 d.3 N 11.25 ft 0 ft 9 in 0 ft 4.5 in None Exterior 50% 3 N Vinyl Low-E Double Yes 0.35 0.3 N 5.5 ft2 0 It 31.510 ft 26 in None Exterior 50% 4 N Vinyl Low-E. Double Yes 0.35 0.3 N 5.7 ft2 0 It 31.5 10 ft 26 in None Exterior 50% 5 W Vinyl Low-E Double Yes 0.35 0.3 N 12.5 ft2 0 ft 44 In Oft 18 in None Exterior 50% 6 W Vinyl Low-E Double Yes 0.35 0.3 N ISft2 Oft 49 in 0 ft 4.5 in None Exterior 50°% 7 W - Vinyl Low-E Double Yes 0.35 0.3 N 11.67 W 0 It 54 in 0 ft 4.5 In None Exterior 50°% 8 S Vinyl Low-E Double Yes 0.35 0.3 N 15 ft2 0 ft 26 in 0 ft 8 in None Exterior 50% 9 S Vinyl Low-E Double Yes 0.35 0.3 N 10 ft2 0 ft 26 in 0 ft 8 in None Exterior 50% 10 E Vinyl Low-E Double Yes 0.35 0.3 N 43.23 ft2 Oft 52 in 0 ft 13.5 i None Exterior 50% 11 E Vinyl Low-E Double Yes 0.35 0.3 N - 6.5 112 0 ft 34 in 0 ft 13.51 None Exterior 50°% 12 E Vinyl Low-E.Double Yes 0.35 0.3 N 12.5 ft2 0 ft 39 in Oft 13.51 None 'Exterior 60% 13 E Vinyl Low-E Double Yes 0.35 0.3 N 12.5 ft2 0 It 47 in 0 ft 13.51 None Exterior 50% INFILTRATION & VENTING - Forced Ventilation - Terrain/Wind Method SLA CFM 50 ELA EgLA ACH ACH 50 Supply Exhaust Run Time Shielding Best Guess 0.00050 1483 81.4 153.1 0.365 8.74 0 0 0 Suburban / Suburbafn MASS Mass Type Area Thickness Furniture Fraction No Added Mass 0 ft2 0 ft 0.3 APPROVED BY INA11/10/09 "INC. 11/51200911:33 AM EnergyGauge® / USRFSS v2.8 Page 2 of 4 Building Input Summary Report A EIE®UIRES INSTALLATION OWSITE, SY OTHERS. COOLING SYSTEM . # System Type Subtype Efficiency Capacity Air Flow SHR Ductless 1 Central Unit Single Package SEER: 13 16 kBtti/hr 480 cfm 0.76 False —Dow AM N DIM" HEATING SYSTEM # ly= Type Subtype Efficiency Capacity Ductless - 1 Electric Heat Pump None HSPF: 7.7 15.5 kBtu/hr False HOT WATER SYSTEM # System Type EF Cap Use SetPnt Credits 1 Electric 0.93 30 al 50 nal 120 deg None SOLAR HOT WATER Collector Type Collector Surface Absorp. Trans Tank . Tank Tank Heat PV Tilt Azimuth Area Loss Coef. Prod. Corr. Volume U Value Surf Area Exch Eff Pumped Pump Energy DUCTS — Supply — — Return = Air # Location R Value Area Location Area Number Leakage Type Handler CFM 25 Percent Leakage QN RLF 1 Attic 6 226.2 ft' Exterior 56.55 W 1 Default Leakage Exterior *REQUIRES INSTALLATION 0* S M BY OTMS, TEMPERATURES Program able Thermostat: Y coolingM Jan IX) Feb [Xj Mar (X� Apr HeatinFX1N Jan [Xl Feb tx1 Mar [X] Appr Ventin t[)�d] Jan [Xl Feb [X] Mar [Xj Apr. Ceiling Fans: N Pq May [X] Jun Eq Jul P9 Au IN May [X1 Jun [X] Jul 1XI Aug [Xj may l[�Xll Jun [[�Xll Jul tXl Au N[X)� Sep [X) Sepp [[�Xll Se rA Oct � Oct [X Oct Nov 7( Nov [x] Nov (XI Dec [XI Dec [XI Dec Thermostat Schedule: Schedule Type HERS 2006 Reference 1 2 Hours 3 4 5 6 7 8 9 10 11 12 Cooling (WD) Cooling (WEH) Heating (WD) Heating (WEH) -AM 78 78 PM 80 80 PM 78 78 AM 66 66 PM 68 68 PM 68 68 78 78 78 78 78 78 78 78 78 78 78 78 78 78 79 66 66 66 68 68 68 68 68 68 68 68 68 68 68 - 68 78 78 78 68 68 68 80 78 78 68 68 68 80 78 78 68 68 68 80 78 78 68 66 66 80 78 78 68 66 66 APPROVED BY rP111 /10/09 INC. Approval of this document does not au or approve any deviation or deviations from the requirements of applicable State Lairs. 11/5/2009 11:33 AM EnergyGaugeO / USRFSB v2.8 Page 3 of 4 J Building Input Summary Report APPLIANCES & LIGHTING Appliance Schedule; HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Ceiling Fans (Summer) AM 0.65 0.65 0.65 0.65 0.65 0.65 0.65 0.33 0.33 0.33 0.33 0.33 % Released: 100 PM 0.33 0.33 0.33 0.33 0.33 1 0.9 0.9 0.9 0.9 0.9 0.65 Annual Use: 0 kWhNr Peak Value: 0 Watts Clothes Washer AM 0.105 0.081 0.047 0.047 0.081 0.128 0.256 0.57 0.849 1 0.977 0.872 % Released: 60 PM 0.779 0.698 0.605 0.57 0.581, 0.57 0.57 0.57 0.57 0.488 0.43 0.198 - Annuai Use: 0 kWhNr Peak Value: 0 Watts Dishwasher AM 0.139 0.05 0.028 0.024 0.029 0.09 0.169 0.303 0.541 0.594 0.502 0.443 % Released: 60 PM 0.377 0.396 0.335 0.323 0.344 0.448 0.791 1 0.8 0.597 0.383 0.281 Annual Use: 0 kWh/Yr Peak Value: 0 Watts Dryer AM 0.2 0.1 0.05 0.05 0.05 0.075 0..2 0.375 0.5 0.8 0.95 1 % Released: 10 PM 0.875 0.85 0.8 0.625 0.625 0.6 0.575 0.55 0.625 0.7 0.65 0.375 Annual Use: 0 kWh/Yr Peak Value: 0 Watts lighting AM 0.16 0.15 0.16 .0.18 0.23 0.45 0.4 0.26 0.19 0.16 0.12 0.11 % Released: 90 PM 0.16 0.17 0.25 0.27 0.34 0.55 0.55 0.88 1 0.86 0.61 0.28 Annual Use: 1360 kWhNr Peak Value: 444 Watts Miscellaneous AM 0.48 0.47 0.47 0.47 0.47 0.47 0.64 0.71 0.67 0.61 0.55 0.53 % Released: 90 PM 0.52 0.5 0.5 0.5 0.59 0.73 0.79 0.99 1 0.96 0.77 0.55 Annual Use: 2104 kWhNr Peak Value: 386 Watts Pool Pump AM 0 0 0 0 0 0 0 0 0 1 1 1 % Released: 0 PM 1 1 1 1 0 0 0 0 0 6 0 0 Annual Use. 0 kWhNr Peak Value: 0 Watts Range AM 0.057 0.057 • 0.057 0.057 0.057 0.114 0.171 0.286 0.343 0.343 0.343 0.4 % Released: 100 PM 0.457 0.343 0.286 0.4 0.571 1 0.857 0.429 0.286 0.229 0.171 0.114 Annual Use: 0 kWhNr Peak Value: 0 Watts 'Refrigeration AM 0.85 0.78 0.75 0.73 0.73 0.73 0.75 0.75 0.8 0.8 0.8 0.8 % Released: 100 PM 0.88 0.85 0.85 0.83 0.88 0.95 1 0.98 0.95 0.93 0.9 0.85 Annual Use: 775 kWh/Yr Peak Value: 106 Watts Well Pump AM 0.05 0.05 0.05 0.05 0.05 0.05 ' 0.1 0.1 0.1 0.1 0.1 0.1 % Released: 0 PM 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 Annual Use: 0 kWh/Yr Peak Value: 0 Watts APPROVED BY ON14INC. 11/10/09 Approval of this document does not authorize or approve any deviation or deviations from the requirements of applicable State Laws. 11 /5/200911:33 AM EnergyGauge® / USRFSB v2.8 Page 4 of 4 Al bra y 7y 1Y_t J/5' I I/f y_y I I/t r_fl. s 7A' s•_Y s 7/1' ,S-7 s/5' s 7� Q fY-71/P 2r-196/d' x-05J5' IR-s +114ra fU-0!/i 11 IS -I've 21-Ili• 7Y-111p' 7Y-07/Y x-R 1%f Wtlt Off[ 6�1/V Irfa0 BID l�Bl5YOSYKIYiIII-AM EL SDC s''/iHCL HI ,WM1E1._---- F IIS Np/L b'2' OLOAIIWIq V* .. j,%I1 as nu wm w - aI%! �V('I V i I i �YRw� I YIY9 of I I w a xY�uL2 a .� tOAL RYll�l O b / OVAL ss,uo®y �w � \\\ .) k i� 9y, Hu� �1 / RY REP. �� I t; €� ie-ORMt'0muMr"rs d LIwNG ROOM Ins Y Fs 0 63802 Y D•� P'sx Y R1�' ` /ONAL P n .Y� e11/!Ya Y a1f O '"G GF AY1e /q1p n HI@._O'O°O° a g u m -IIC�It / s 2tum I/---c_ b L$ 7. cEj 4 i P �` i\ i t I±x1 O[ I O a °t °" F LI.....�°...... F 1 O _ RYI�Im. -- i pp RD e � 19]R / H um a.a DINING I ��� i ��`� I O $eF4 �:.°., •. I «to `9 \\,-MIR\� °H L. n�� I k - � 1 ' ®£�=®F � 5 I BEDROOM 01 I I ti ® rWHam. IO ccjjo'° — c pa / 0 In$R ��� I �18L \ 91 m All XMAR W1lEE I i I II a� br + \ iYE-u2 °°41 ' i^'`;' °•x,'° s °.�A 0 0, � OL IDR A SEI eDa fR HFI ROE PiB. - I 9 1W 56 n �' I I uv m6 IHIE fim. I � � € 4 � �' ' H 1651 M YZ 9Q1/4 — — — — — — — -i li"r,: �'. 00 EXTERIOR SHEATHING NOTE OM y; USE 5/B- FlRE-SHIELD GYPSUM YY-11' IT-91/1• ffi-!s/7 x-7 s/P 0-1J(f 5r-21n• MCP-1B86-464R Q E P p R t HITCH WALLBOARD ON THIS SIDEWALL. O (8071SIDES OF THIS SIDEWALL) 11-4 y2• 1 (: '; Q Q� mm0® Il�oO oo`�y!l �fOml6s1� IDaalrrr®rrrlr>✓al� L 1�11111�1®tttt!'� III®IOlrrrrvai, Mi �11t�llllt��•N Iti(=1p1111�®�:XJ 57T tY31/Ir /1 f 3i 7/d Y-t ?-It s/B• fY-0s/f �1911� Y-51/8 § 5 8 Y .. s7/r PLAN NOTES: a tsm.a 1 f 1Y-07/A' 1 1 I, fFLOOR lorrqo Sr-x e• aeIOFuzurRO ,J$EID117/NI✓OafW tY-9•SMTIf�mm J �( 51'dootf1141 ID-s•Ir 7/�r LIL RMM Ifd(mmmwRw j' xd(1f U1. MMW _ wuic er`o_"'0 IDIB Q7➢ YOGI IOi96 (tY-51/7) WYIYIOJbEDMUM512M - ----: Sn� - r=, C-, 1/f 51 I n9 (a ,m + - cp m� '----- M-„/5' I If-11/5• sun w•`o i um ue m o°iwoOA`�° "(d,: �.. ,. I � —/C I fY-R 71E' I I (e � IY-0,/i —( H'-r --1 7Y-D 7/1 �-0 I I I%9 ]/f se r —I I dam m. I0. n• w+xua wvro..r� .c mr vnw•Ren4 �o onM©MI ®o®I© oa©m= an In= AMU=�Dan HIME mmm©IMI ,omnm©M®Enna Enn©= �III FARWALL a 111. DESIGN SPEDS a � e P I: nu�o (NOR: DOOR AND TAANSOIA AFT 0 K SIN[ UM) RIGHT ELEVATION ELEVATION NOTES: BSEN rouxo•n]x I6 D1sTAueD oxure er DTNeM AWP velmunon wT ee •cWNrLISNeD nwawx uY PXe .. —ATE. —1 DB —1 s 6xcan wr ee ovrlawl_ 6°"Xe R[Ns sxlwx BMUmC Bn[ DDITMGTIDN MD IB B,MOT TO Ill "M Al. LDO4. Cllee AND IHBPECrIWB Txe 8 B oP TNEle xeTIKRB wT er elel wY 11. BDNe IT[N! 11— CT eG ON-0R er DM[B8 ES erxe�uB axorvn w. ee ox srte, eY Dn¢BB. X i VANT, NOT LOBBED eY T E. S— IN IN—INAnox B B- mT2ttMTMq IeAvel SIi[! Wl xAlrr. I'll- BEM EAVG A. tl v]. •BNI fill! —1S 10. rx. —I— M[i necruBAL 910N9riND°�- —1 PBDN 1NE'- EteV - r TMG n[XS — Al BIDMO Tier. 6xuITEB9, INerI D Tx[ OABAO! — AND BE= 8 POUxDATIDN ME .-.TI, El DT. . -1 PBBN 10 TD 6• MOxINLL 64[6. M OA1°Tx pmADBT PAW BNML e! VENTED To Tx! W[ Tri[, E-1ATM IT[NB, [TO.. wT VMY PBDx Tx^_er [L[VAnOHB BHDVM Breve PND RABB ME DN�ene, 1Y OTxeNB. LsuWCMlxo TTPICA4 OetBrte, ar orx[BS 11 1111 DP 11 11110OAll 1-1 rXIT e11—T Nio x:Dp AVIrY Tx D BPMe. 0 ulY n. BERPB ANI — AR,oNBire, er oTHere. meeu P B e ITENa 'd COUft, xGrvJe Wln •B[ mSr•u[D IN ° eT o > MD wr ee Bnowi�TrBPo4 6x6rM x• N oN rvIT DUI "- B o•veeDro"DiA',NL .1 I.E.E ruve°Iwr ee --EE' 6BT°aLt¢Be. u Be n O m A Srt ARE, All I — El er°oiweBe . MalAN.' ir,. FL 34695 ). TOx ro tYPIILL oMLT, n0N9 oP OtT1.EI NAT x cwxoel eY .1 eu-1 [DNTMGT i 6RR III LN [ TD BIDC At9MI E. TO Cx% n. iOUeDATroX 1 MEmML WD1TiDx nGT1DX 19 oxR, BY DTxeR4 MI.- A°Glro° eLOVECT TD mBPEcnON If0 APMDYLL IT THE LWLL IT BCnR.IED TTTNDYr NtrAPPRDVLL OP PLMe 1-1138 rD orxeBa .IACD°seN I. xD:eO Mn Ire rx rxe WaDIxD Pwro sx.0 erIN No 2 O IL 1- a 7AN ►p Cam' MOD-464 I FOR USTIN S AGENCB' 6Nr.nu,r O BDa, A.w°AeB x°,aa u[eTr xueaa x.wmA ... Bwm Be.orvee u f0.PDAZM VENTAATIM left ELEVATION ELEVATION NOTES: ❑❑�❑ F'^`I `'• a �' n. was LrexB SNovm Wr ee reTiDW� L Re, er orxGs a Accowusxep nuw.m wG UeG ❑❑■ ❑ ' H ®I V I ES ANO IB BIMGT TO ,LLL BTATG .WO LOOK DOD[B a D m xs LOx9 Wr ee oN ane, er Draea. sne Lreus xir°vur xDT eavGrteo er rxeee PP ' OP [RX[FxVeTMILARD GVCB qt ROOP BePABA eLYx ox ralvLTGr11p09 WT Y UaCO jGvel ea n wr vw rrnca. PeM Aft! n Vp• AM BN! GV[s TMB 9NOWN WT PlOU11R BRlI RLST CLA�TIIXG 1S M IRNB Bl . WY BC ON-e. aevnnon Me A. Mfxrt'ec NPu m 'oe"zioxs •xo Wr vrtr Plox Txe AcrvK eLevAnox OP P niRG rYR, NNN —Dw WH[N LNBTALLGD TX! OAPAD[ PLOOR MD ft[OD B PDUNDATIOH MC OV-BIT4 aT OTXGRae CAVeB vMTTPft�ON 10' TO e• NpNIW1L fin[& BATH Ol P B[ KNTLD To TM! 6xmOLe TYP[ 61NTi[R6 p[OOeATM IRNB [TO_ WY ftY PBON TX[BG !L[VAnOx9 BNOaT1 ' ❑„❑ •' A M BT[PB MD ftM.B MC OMBRe Y on1CR0. e L•wwMIND rYPrut, Ox-sLtS BY On�exa OF 8U NO TeftITMOft Or rNC GOUILDIONOp ND aXwNQNOT [xKe �0. °s NOP at TY I 8KM8[CMiUD MR8 AM DManq BY OTMlRB x0 Port efre LRxe, eTe� CaO. 600 Paikartl,CouPt 6 o xexrDw .Elie Arte mar•u[o Duane, e eY OTNlfte AxD WY D[ ft[I.wATGD PBON 4NOWn n euaeiuB 1 ae unu�ee wRNDw11DpurT WY DC 4LVPGY A Tx .xG D[618tSD ANMG IN9TKLGD aY OTNGft9 � JAwaBeq MD ❑❑❑❑ Safety Harbor , 34695 s ). [LlYAnON n TY1 OxLY. -DER —. OOP—Cxttft Wr aG CNAlxreO lY TXe Gµ0DIx0 vAcraft, auven TO LoeK APPwv n IOU —DC AND%ql [!D TO CMOI �wXp,T'o„ veNTe M[ MLOK'm A vexnunan La oualre, Br oiL¢ftB. • noN MO MAOYK aT Txe LOCK �LHw01CT10N xTOivao ewolxonTr. ao wr x wavoeo mTXwr u-MGovK ar PLAxs 72)-726-1738 3 _�a. wNex rovw.nox wxe .aB ovm,¢D ar rNu�.L.eoesex Nouev win ne rxno PMrr Mr•evK Awxxw .Lnw nLrN upr ae Nm Bevroxvmxe oW LUBLe Pu Tne TNe ••cxLrecr Morin exmxeev v rNG emwmo rLwrm BUKL o 63802 ?� VE 0 . Dj�L�� ��,11/6/2009 11 1110 ,O L.n N { � N Ln Z O D y D w O nj A w _ a O W Q W �evdoLs' w m3 IMF 10. MOD-464 Ip f00. LISTING AGENCY APFCOVAL 51 `. . It g� f. e B 11110109 m v —•-- NO ` INC. bax.�x. e ME:—- 6 OF 12 xYFO: zanuvNr O,00x ,XcaePrt. •o•e., wa,Y x•,eoA •.oPm., •.A w,.. ti-se..e. a Li wx. nen" m:i nxoM11N M10� uNiil iRe K°e r�w tw�oRo it ,x. w.:, enpa Rmcu! w•re,vccRYx.x.Y mw cuc<c R• U mMix°mR .�Puoe .Ne Cwsro ax mt wx. uR1wnw.pe�•eM ianccceRPA/y.Nox.q OneclFleo Ro w. J� TaMm�Im�xe Y.M x wKc eoe w xRu .tcitoq w na•..wnu.wnue..mrna.. �eWaiem. xm .nnr reurm ntam.�m .�� \°:w ��xl � nxs ¢�ooTDln.l e.x n rt Tm ^i xxcWeea bT a.YM ox.ws uo cN mq .mu [u.a4icV e[loWc�1 u� pbiw lox YUN4 7 e�gwx tRu..r�x ,xTwLLYewr Kx,<..w --- ecN R.tt .t. x0x4 YM [[MR ett .mms..i.ciRrLL r.cv.r .m v.0 z AIR SPACE DETAIL P6 SCALE: NIS �mw ROY n� aroe ,ui ,voa .qn*. mmt:w ___� —��«xN.e<.a.,.e.eo,t.tt.,D�x�t..,x„q..,,a•. x..xeun niwY �^;v*4 ei mnvu ., x xR ° . a= o/or? �a.x...xt R.R.Yxt em M1I v.ro. e.r.v.l °ao >n et rt. f0rn eMvtcR vbrt rtciu wlCe . i..Rxtq w ,xe T.— A.iucluet uncx ttftt, mTLL IgxA vtxc .cNULv .eT'IC[R ux ..o veRq Po� .W 1Rp[ lOx Brtti E t [�ele T '2xie atR Rmu nx xwel _ vrtcT , a„`.t°T,""LL I;;' ,MCONSTRUCTION SPECIFICATIONS:=;r .aq.w ePTavct YTRexxliec9 T. cCTW.yr. 'Ro . OR RMN. n. WM ,w rurt ¢.,, ,a.m n .n..x.�we ns.r, w nco ...m m. ewu ueuv n., e..0 w = seat :wa+cv¢ a ROOF VENT CALC�Rt X.11 r wwm.� �Rx wn A .n.w .�• x� �i �.wm�w�. w PB SCALE: NTS Ir� —.. __ 9dddddddddd."'fDdddddddddda _ �_ �O.Ddb Hdddddd//ddddd9dd9dB.9I Imo\ 9dddA.Y/ddd�dddddddd9.O/ rwxrre..,:r w ineiq°a°w io �'x'RAHic.°I Mo D-464 i TYP. CROSS-SECTION P6 SCALE: NTS NoTES: *o nee . °wro.nen eux _ Mx § egtwrnxwan,nun eP to xn o 63802 .. / - ROOF SHEATHING M� -- ! P9 — SCALE: NTS ice-+. M IQF Ip4 IQ>". ,Q@ AREA RFSFRVEO FOR USTING AGENtV ""OVAL SiMiS . ROVED BY INC. tcrt.gxr OeRoe, ..Rw.ex xwRs, ..xn wRoq,vogt..u.axn fvox,: garnet t MECHANICAL NOTES: MECHANICAL NOTES: (CONTINUED): *111 `xaTM ueo a A ' , 1 IkIT, I I kiIk l Ls � - Q�v / � A , I 1 I 11 HVAC LAYOUT MOD-464 MINIMUM REQUIRED EQUIPMENT SPECS: GALL CLIMATE ZONES: m/(iQa � `oeRruT:°�wv°M1°`c."nae o 63802 5 �W 5 o H a W O O �. R.vhbns Ley peu� IO ip rp ip Ip RFS M FOR L6TING AGENCY "FROVAL-TAAP� �faketl. No 11NOI09 INC. dawnoA �i: °• s:ae bie,l: 11/6/2009 01/15/2006 04:51 SLC INSPECTIONS St Lucie County Inspections 2300 Virginia Avenue Ft Pierce, FL 34982. (772) 462.2172 CERTIFICATE OF TERMITE. TREATMENT CONSTRUCTION SOIL TREATMENT PERMIT #014 JOB ADDRESS �ta. Q�,�,t t c% BUILDER i>L/1_Z01?A L 0A t- PEST CONTROL CONTRACTOR C W le>J$� PEST CONTROL LICENSE # . e %O&vl .PAGE 01/01 We, the undersigned, hereby rectify that we have pretreated the above -described construction for subterranean termites in accordance with the standards of the National Pest Control Association. Square feet of area treated: L �� Percentage of solution: .25 Date of treatment: ❑ Footing ❑ 1st Treatment / El-Re-treat(� Slab 1st Treatment ❑ Re -treat ❑ Driveway ❑ 1st Treatment ❑ Re -treat ❑ Pools ❑ 1 st Treatment ❑ Re -treat ❑ Other ❑ 1st Treatment ❑ Re -treat Chemicals used:�C- Total ga]lons Useds`_/o?O &1- ')4 f%a44 L Time of Treatment:_ _ 9 • FBC104.2.6 Certificate of Protective Treatment for prevention of termites. A wegrlter risisranr jobsite posting board shall be provided to receive duplicate Treatment Certiffcams as each required protective treatment is completed, providing a copy for the person the permit is issued to and another copy far the building per►nit, files. The Treatment Certificate shall provide the product used, identity of the applicator, time and date of the Treatment, site location, area treated, chemical used, percent concentration and number of gallons used, to establish a verifiable record of protective treatment. ifthe .toil chemical barrier method for termite prevention is used, final exterior trearment shall be completed prior to fiial building approval. St Lucie County requires for the final inspection for CO, a Permanent Sticker to be placed on the electrical panel box cover, listing. all the treatments and dates of applications. ❑ Perimeter for Final Inspection NOTE: Signature of exterminator There Must be a completed form for each required treatment or re -treatment and this form must bean the job site to be picked up by the inspector at time of each inspection or the scheduled.inspec on will fait and a re -inspection fee charged. Revbrd 6113102 dmg A A S.`D"EPARTMENT OF HOMELAND SECURITY ,-LEVATION- CERTIFICATE '� OMB No. 1660-0008 t,_ Federal Emergency Management Agency Expires March 31, 2012 National Flood Insurance Program Important: Read the instructions on pages 1-9. C SECTION A -PROPERTY INFORMATION For Insurance Company U56 . _.._ Al. Building Owner's Name BEVERLY CHESNACK Policy Number - " 9 (including P g• ) P y .- - ._ A2. Building Street Address mcludin Apt., Unit, Suite, and/or Bldg. No. or P.O. Route and Box No. Gom� an_ NA'IC Number, 808 Osprey Court City Fort Pierce State FI ZIP Code 34949-8442 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) Lot 343, Ocean Resorts Co-op subdivision, St. Lucie County, Florida. A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) Residential A5. Latitude/Longitude: Lat. 27°31'57.5"N Long. 80.19' 02.7"W Horizontal Datum:❑ NAD 1927 N NAD 1983 A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. AT Building Diagram Number 8 A8. For a building with a crawlspace or enclosure(s): A9. For a building with an attached garage: a) Square footage of crawlspace or enclosure(s) 1144.0 sq ft a) Square footage of attached garage n/a sq ft b) No. of permanent flood openings in the crawlspace or b) No..of permanent flood openings in the attached garage enclosures) within 1.0 foot above adjacent grade 10 within 1.0 foot above adjacent grade n/a c) Total net area of flood openings in A8.b 2073.6 sq in c) Total net area, of flood openings in A9.b n/a sq in d) Engineered flood openings? N Yes ❑ No d) Engineered flood openings? ❑ Yes ❑ No SECTION B = FLOOD INSURANCE RATE MAP (FIRM) INFORMATION' B1. NFIP Community Name & Community Number. B2. County Name B3. State Unincorporated 120285. St. Lucie Florida B4. Map/Panel Number B5. Suffix B6. FIRM Index B7. FIRM Panel B8. Flood B9. Base Flood Elevations) (Zone 12111 C0087 / 0087 G Date Effective/Revised Date Zone(s) AO, use base flood depth) November 4, 1992 August 19, 1992 AE 5.0 B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9. ❑ FIS Profile N FIRM ❑ Community Determined ❑ Other (Describe) B11. Indicate elevation datum used for BFE in Item 139: N NGVD 1929. ❑ NAVD 1988 ❑ Other (Describe) B12. Is the building located in a Coastal Barrier Resources. System (CBRS) area or Otherwise Protected Area (OPA)? ❑ Yes N No Designation Date ❑' CBRS ❑ OPA - SECTION C - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) Cl. Building elevations are based on: ❑ Construction Drawings*. ❑ Building Under Construction* N Finished Construction *A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations -Zones Al-A30, AE, AH, A (with BFE), VE, V1-V30, V (with BFE), AR, ARIA, AR/AE, AR/A1-A30, AR/AH, AR/AO. Complete Items C2.a-h below according to the building diagram specified in Item AT Use the same datum as the BFE. Benchmark Utilized LocalVertical Datum C.C.C.L. 1988 (NGVD'29) Conversion/Comments Check the measurement used. a) Top of bottom floor (including basement, crawlspace, or enclosure floor) 4.16 N feet ❑ meters (Puerto Rico only) b) Top of the next higher floor 7.05 N feet ❑ meters (Puerto Rico only) c) Bottom of the lowest horizontal structural member (V Zones only) = n/a. Cl feet ❑ meters (Puerto Rico only) d) Attached garage (top of slab) n/a. ❑ feet ❑ meters (Puerto Rico only) e) Lowest elevation of machinery or equipment servicing the building 5.01 N feet ❑ meters (Puerto Rico only) (Describe type of equipment and location in Comments) f) Lowest adjacent -(finished) grade next to building (LAG) 4.7 N .feet ❑ meters (Puerto Rico only) g) Highest adjacent (finished) grade next to building (HAG) 3.8 N feet ❑ meters (Puerto Rico only) h) Lowest adjacent grade at lowest elevation of deck or stairs, including 3.3 N feet ❑ meters (Puerto Rico only) structural support SECTION D.- SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. I certify that the information on this Certificate represents my best efforts to interpret the data available. 1 understand. that any false statement may be punishable by fine or imprisonment under 18 U. S: Code, Section 1001. N Check here if comments are provided on back of form. Were latitude and longitude in Section A provided by a licensed land surveyor? N Yes ❑ No Certifier's Name Frank S. Cuccurese, P.S.M. License Number 4765 Title Professional Surveyor and Mapper Company Name Carter Associates, Inc. Add 1st Street City Vero Beach State FL ZIP Code 32960 Sig ure Date REV. 8-31-2010 Telephone (772) 562-4191 FEMA Form 81-31, January2003 See reverse side for continuation. J, SEAL' rBEIRF Replaces all prev IMPORTANT: In these spaces, copy thy; `responding information from Section A. For Insurance, Company Use: " Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number 808 Osprey Court City: Fort Pierce State: FI ZIP Code 34949-8442 Company NAIC.Nuibber SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION (CONTINUED) Copy both sides of this Elevation Certificate for (1) community official, (2) insurance agent/company, and (3) building owner. Comments C.A.I. Project No. 09-299S, Drawing No. 18439-A, fb755wp-61 C2e) Auditioning slab on west side of building N .Check here if attachments SECTI. E = BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED).FOR ZONE AO AND ZONE A (WITHOUT BFE) For Zones AO and A (without BFE), complete Items El-E5. If the Certificate is intended to support a LOMA or LOMR-F request, complete Sections A, B, and C. For Items E1-E4, use natural grade, if available. Check the measurement used. In Puerto Rico only, enter meters. El. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent grade (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor (including basement, crawlspace; or enclosure) is n/a. ❑ feet Elmeters -]above or ❑below the HAG. b) Top of bottom floor (including basement, crawlspace, or enclosure) is n/a. ❑ feet ❑ meters ❑ above or ❑ below the LAG. E2. For Building Diagrams 6-9 with permanent flood openings provided in Section A Items 8 and/or 9 (see pages 8-9 of Instructions), the next higher floor (elevation C2.b in the diagrams) of the building is n/a. ❑ feet ❑ meters ❑ above or ❑ below the HAG. E3. Attached garage (top of slab) is n/a. ❑ feet ❑ meters ❑ above or ❑ below the HAG. E4. Top of platform of machinery and/or equipment servicing the building is n/a. ❑ feet ❑ meters ❑ above or ❑ below the HAG. E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must certify this information in Section G. SECTION F - PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA-issued or community -issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge. Property Owner's or Owner's Authorized Representative's Name Address City State ZIP Code Signature Date Telephone Comments ❑ Check here if attachments SECTION G -COMMUNITY INFORMATION (OPTIONAL) The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B, C (or E), and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement used in Items G8 and G9. G1. ❑ The information in Section C.was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.) G2. ❑ A community official completed Section E for a building located in Zone A (without a FEMA-issued or community -issued BFE) or Zone AO. G3. ❑ The following information (Items G4-G9) is provided for community floodplain management purposes. G4. Permit Number . G5. Date Permit Issued G6. Date Certificate Of Compliance/Occupancy. Issued n/a n/a n/a G7. This permit has been issued for: ❑ New Construction ❑ Substantial Improvement G8. Elevation of as -built lowest floor (including basement) of the building: n/a. ❑ feet ❑ meters (PR) Datum G9. BFE or (in Zone AO) depth of flooding at the building site: n/a. ❑ feet ❑ meters (PR) Datum G10. Community's design flood elevation n/a. ❑ feet ❑ meters (PR) Datum Local Official's Name . Title Community Name Telephone Signature - - Date Comments ❑ Check here if attachments FEMA Form 81-31, Mar 09 ___ Replaces all previous editions JOSEPH E. SMITH, CLERK OF THE CIRCUIT COURT - SAINT LUCIE COUNTY , FILE # 3451302 OR BOC-r 1-178 PAGE 2671, Recorded 03/16/2010 '"-',11:49 PM AFTMRWORntttnnfimxN70, �...-.._ �)/ PERMIT NUMBER: NOTICE OF COMMENCEMENT r The undersigned hereby given notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida statutes the following information is provided in the Notice of commencement. 1. DESCRIPTION OF PPH-0OPERTY (Legal description and sneer address) TAX FOLIO NUMBER: 1`i 10 S 010 3 4 3 0 0 O ^( SUBDIVISION.Q �N5N BLOCK TRACT_�AT*�_Bp)&--_ UNIT .�.^ rrao 1`//los 2. GENERAL DESCRIPTION OF IMPROVEMENT: 3. OWNER INFORMATION: a. Name__ b. Address o rc I- • — _. interest In property o t..h a t+ d. Name and address of fee simple titleholder (if other than owner) 4.CONTRACTOR'S NAME, ADDRESS AND PHONE NUMBER: Mich&eL 7urde.tJ trttF�e 22q l4atgvA ue- l L. �31.3-9�os o883 5, SURETY'S NAME, ADDRESS AND PHONE NUMBER AND BOND AA OUI)1T: 6. LENDER'S NAME, ADDRESS AND PHONE NUMBER: 11/14 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13 (lxa) 7., Florida Statutes:: NAME, ADDRESS AND PHONE NUMBER: �'1• ` 8. In addition to himself or herself, Owner desi aces the folowing m receive a co y of the Lienor's Notice as provided in Section 713.13 (1)(b), Florida Statutes:L3d1C (p PV • 3� �G'� NAME, ADDRESS AND PHONE NUMBER: , 9. Expiration date of nod f c ^cement (the expiration date is I year from the data of recording unless a different date is specified) , 20_ - avn&r Print None and $iovide Signatory's 1111dOlfice Owner's State of Florida q�+ County of MixaAV N LL •� The foregoing instrument was acknowledgedi J before me this day of V an qAr y , 20 / n (Name of pers (Type of authority... e.g. Owner, officer, tnistec, attorney in fact) For , a � t I-. 01ke5 n eA (Name of parry A behalf of whom instrument was executed) Personally Known_ or produced the following type of ID: JEAN E. LWBERT t mreofNo Public)•„ `a EXPIRES: October 2i,tU?2 (Printed Name of NotaryPubUc) (S� t�Y ,�� •, gmdsa7pmNoaryPraricUndenrriura Under penalties of perjury, I declare that I have read the foregoing and that the facts in it are true to the best of my knowledge and belief (section W25, Florida Statutes). S s) of Owner() or Owner's)' Auth OffieedDlree wA%irtnerlManager who signed above:By. j A av IJGt/�5ani STATE OF FLORIDA ST. LUCIE COLINTYTHIS IS TOCERTIFYTHATTHIS IS TRUE AND CORRECT OPY Of THE ORIGINAL. JOSEPti EASMIT By: Date: ST. LUCIE COUNTY BOARD OF COUNTY CON NUSSIONERS FRANNIE HUTCHINSON CHAIR DISTRICT 4 LINDA BARTZ VICE CHAIR DISTRICT 3 CHRIS DZADOVSKY DISTRICT 1 ANTHONY BONNA DISTRICT 2 LATHY TOWNSEND DISTRICT 5 HOWARD TIPTON COUNTY ADMINISTRATOR DAN MCINTYRE COUNTY ATTORNEY MAILING ADDRESS 2300 VIRGINIA AVENUE 'FORT PIERCE, FL 34982 PHONE (772) 462-1553 TDD (772) 462-1428 FAX ' (772) 462-1578 E-MAIL PERM ITS@STLUCIECO.ORG PLANNING AND DEVELOPMENT 'J SERVICES DEPARTMENT Building & Code Division April 5, 2018 Michael Chesanek 1450 Old Mims Rd. Geneva, FL 32732 RE: Information setback in Ocean Resorts and variance application for existing structure Dear Mr. Chesanek: Please accept this letter in response to our phone conversation at April 3, 2018 to discuss the setback for a raised deck on the side and the rear of your property at 808 Osprey Ct. Fort Pierce. Attached please find section 7.10.16 of St Lucie County Land Development Code. Based on section 7.10.16 (Q) the minimum required side yard is 8' unobstructed between adjacent units. The rear yard requires 5' and the front yard 10' setback. Steps or ramps may encroach in the rear or front yard provided that the steps or ramps do not occupy more than ten percent of the required front or rear yard unless otherwise approved by the St Lucie County Board of Adjustment. Based on photos of your property, the existing raised deck and steps at the side and rear yard are not meeting the minimum required setbacks as provided in section 7.10.16 of the Land Development Code. An approval from the Board of Adjustment is required before you can submit for a building permit. See attached the application and supplement to apply for a variance. Please contact Bethany Grubbs in the Planning Department at (772) 462-1687 if you have any questions or when you are ready to submit your application to apply for a variance. Please feel free to contact me at (772) 462-1555 if you have any questions. Sic el Lydia Galbraith Zoning Specialist Building and Code Division galbraithl@stlucieco.org WEBSITE WWW.STLUCIECO.GOV 7.10.16. - Recreational Vehicle Parks. I Land Development Code I St. Lucie County, FL I ... Page 1 of 2 Q. Permitted Specific Uses andAdditions 1. Any Recreational Vehicle Park, occupying more than ten (10) acres, unless located on North or South Hutchinson Island where there shall be no minimum acreage requirement other than that set out in Section 7.10.15(C), is permitted to have installed, erected, constructed or otherwise placed on site Recreational Vehicles, Travel Trailers, Detached Single -Family Residences, Class A Mobile Homes and additions thereto, including wood decks, screen rooms, patios and like accessory facilities subject to the following requirements: a. 1. The following minimum yard requirements shall be maintained: in all recreational vehicle parks existing on or before August 1, 1990. (a) Front yard -ten (10) feet* (b) Side yard -eight (8) feet unobstructed on the left side and zero (0) feet on the right side when facing the lot from the center of the main street frontage. In the absence of recorded lot lines, a minimum eight (8) feet unobstructed between adjacent units shall be required. (c) Side yard corner - eight (8) foot left side and five (5) foot right side when facing the lot from the center of the main street frontage (includes all properties adjacent to public and private roadways). In the absence of recorded lot lines, a minimum eight (8) feet unobstructed between adjacent units and five (5) feet from any common use area shall be required. (d) Rear yard -five (5) feet. * Note: The front yard setback for special situation lots shall be five (5) feet. Special situation lots include those lots in which the longest property dimension is found along the street frontage. Common use areas shall refer to public and private roadways only. Lots adjacent to pedestrian access shall not be considered corner lots. For lots with double street frontage, the front yard shall be identified on the approved site plan of the particular Recreational Vehicle Park, which shall be kept on file with the Community Development Department. The front yard for a block of double frontage shall be consistent the length of that block. Double frontage lots are not eligible for special situation consideration or designation. Any deviation or change to the front yard designation that does not include the adjustment of the entire block shall only be approved by the Board of Adjustment in accordance with Section 10.01.00. https:Hlibrary.municode.comlfl/st. lucie_county/codes/land development code?nodeId=C... 4/25/2018 7.10.16. - Recreational Vehicle Parks. I Land Development Code I St. Lucie County, FL I ... Page 2 of 2 2. In all recreational vehicle parks created after August 1, 1990, including the expansion of any existing recreational vehicle park. (a) Front yard -twenty (20) feet (b) Side yard -ten (10) feet left side and zero (0) feet on the right side when facing the lot from the center of the main street frontage. In the absence of recorded lot lines, a minimum ten (10) feet unobstructed between adjacent units shall be required.; and (c) Side yard corner - ten (10) foot left side and eight (8) foot right side when facing the lot from center of the main street frontage (includes all properties adjacent to common use areas). In the absence of recorded lot lines, a minimum ten (10) feet unobstructed between adjacent units and eight (8) feet from any common use area shall be required. (d) Rear yard -ten (10) feet. No portion, other than a maximum twelve (12) inch unsupported roof overhang, including appendages to the roof, of the Recreational Vehicle, Travel Trailer, Detached Single -Family Residence, or addition, including but not limited to wooden decks, bay windows, tipouts or awnings, may encroach into any required setback or separation area. Steps or ramps for access purposes may be erected, but may not encroach into any required side setback. Steps or ramps may encroach into the front or rear setbacks, if necessary provided that the steps or ramps do not occupy more than ten percent (10%) of the required front or rear yard unless otherwise approved by the St. Lucie County Board of Adjustment in accordance with Section 10.01.00. Steps or ramps which encroach into front or rear setbacks may not have a landing with dimensions in excess of four (4) feet by four (4) feet where such landing encroaches into the required front or rear setback. b. The elevation of a wood deck shall not exceed the elevation of the floor of the recreational vehicle or travel trailer. The design of the wooden deck may include provision for use of the underlying space as a storage area. However, this space shall not be used for the storage of combustible materials nor for the storage or placement of flammable liquids, gases, or liquid or gas fuel -powered equipment. https://library.municode.com/fl/st._lucie_county/codes/land development_code?nodeId=C... 4/25/2018 St. Lucie County, FL Land Development Code Page 1 of 5 10.01.14. - Administrative Variances for the Required Minimum Yard Setback Standards. A. For Recreational Vehicle Parks. 1. Application Procedures. a. A person desiring to decrease any required minimum yard setback in any existing Recreational Vehicle Park on the effective date of this Ordinance (Ordinance 94-007) by no more than fifty percent (50%) of the minimum standard shall apply for a variance on a form provided by the Building Code Administrator or his/her designee. b. An application fee in accordance with Section 11.12.00. c. The application shall be in such a form and contain such information and documentation as shall be prescribed from time to time by the Building Code Administrator or his/her designee, but shall contain at least the following: 1. Name and address of applicant. 2. Legal description of the property which is subject of the application. 3. Size of the subject property. 4. A certified boundary survey for the subject property showing the location of the proposed RV, Mobile Home, or Single Family Residence, along with all setback and distance measurements to all adjacent structures, site improvements and utility services. 5. In those cases where the application submitted is for a variance from the requirements of Section 7.10.16(Q)(2), proof that the existing structure(s) on the adjacent property(ies) is the cause for this application. The applicant must show that the adjacent structure(s) were constructed without the proper Local Government permits or in violation of those permits and as a result of the provisions of Section 7.10.16(Q)(2) has subsequently been granted existing nonconforming status. d. Within a reasonable period of time, not to exceed thirty (30) days after receipt of an application or receipt of additional information pursuant to this Section, the Building Code Administrator or his/her designee shall about:blank 4/25/2018 St. Lucie County, FL Land Development Code Page 2 of 5 examine the application or information submitted and notify the applicant of apparent errors or omissions, and request such additional information as may be necessary for the processing of the application. e. Within thirty (30) working days after an application has been determined to be complete, the Building Code Administrator or his/her designee, shall either grant the variance, grant the variance with conditions or deny the variance with reasons clearly stated. f. Any person aggrieved by a decision of the Building Code Administrator or his/her designee, may appeal the decision within thirty (30) days after the rendition of such decision to the Board of Adjustment pursuant to procedures set forth in Section 11.11.00 of this Code. 2. Genera/Standards forIssuance. The Building Code Administrator or his/her designee, shall grant the requested variance if all of the applicable following standards are satisfied: a. Demonstration that the Recreational Vehicle Park was in legal existence upon the effective date of this Ordinance (Ordinance No. 94-007). b. Demonstration that the existing structure(s) on the adjacent properties have been constructed without, or in violation or, prior permit approvals and that these violations have been granted conforming status consistent with Section 7.10.16(Q)(2) of this Code. c. Demonstration that the placement of the proposed structure will meet the intent of all separation standards as required for all Recreational Vehicle Parks, Mobile Home parks, any other applicable provision of this Code, or the Florida Building Code, fire code(s) and that the requested variance is the minimum necessary to locate the proposed dwelling unit of the property. d. The literal application of the provisions of Section 7.10.16(Q) will result in an undo hardship on the property owners and would otherwise prohibit the use of the petitioned property as others are used in the surrounding neighborhood. e. The variance requested will not result in any encroachment into any access/utility easement or other common area. f. The variance requested does not result in an encroachment of any more than fifty percent (50%) into any required yard setback area. about:blank 4/25/2018 St. Lucie County, FL Land Development Code Page 3 of 5 g. The variance requested will not conflict with any other provision of this Code. 3. Conditions on Variances. The Building Code Administrator or his/her designee, shall attach such conditions, limitations and requirements to the variance as are necessary to effectuate the purpose of this section. B. For Mobile Home Parks. 1. Application Procedures. a. A person desiring to decrease any required minimum yard setback in any existing Mobile Home Park by replacing a pre-existing structure after the effective date of this Ordinance (Ordinance 06-013) by no more than two-thirds of the minimum standard shall apply for a variance on a form provided by the Building Code Administrator or his/her designee. b. An application fee in accordance with Section 11.12.00. Except as otherwise provided herein, the application fee shall be waived for completed applications received by the Building Official on or before December31, 2006. c. The application shall be in such a form and contain such information and documentation as shall be prescribed from time to time by the Building Code Administrator or his/her designee, but shall contain at least the following: 1. Name and address of applicant. 2. Legal description of the property which is subject of the application. 3. Size of the subject property. 4. A certified boundary surveyor a scaled plot plan, as deemed necessary by the Building Code Administrator or his/her designee for the subject property showing the location of the proposed Mobile Home and any accessory structure, or Single Family Residence and any accessory structure, along with all setback and distance measurements to all adjacent structures, site improvements and utility services. d. Within a reasonable period of time, not to exceed thirty (30) days after receipt of an application or receipt of additional information pursuant to this Section, the Building Code Administrator or his/her designee, shall about:blank 4/25/2018 St. Lucie County, FL Land Development Code Page 4 of 5 examine the application or information submitted and notify the applicant of apparent errors or omissions, and request such additional information as may be necessary for the processing of the application. e. Within thirty (30) working days after an application has been determined to be complete, the Building Code Administrator or his/her designee shall either grant the variance, grant the variance with conditions or deny the variance with reasons clearly stated. f. Any person aggrieved by a decision of the Building Code Administrator or his/her designee may appeal the decision within thirty (30) days after the rendition of such decision to the Board of Adjustment pursuant to procedures set forth in Section 11.11.00 of this Code. 2. Genera/Standards forIssuance. The Building Code Administrator or his/her designee shall grant the requested variance if all of the applicable following standards are satisfied: a. Demonstration that the Mobile Home Park was in legal existence upon the effective date of this Ordinance (Ordinance No. 06-013). b. Demonstration that the placement of the proposed structure will meet the intent of all separation standards as required for all Mobile Home parks, any other applicable provision of this Code, Florida Building Codes or the fire code(s) and that the requested variance is the minimum necessary to locate the proposed structure on the property. c. Demonstrate that a similar structure existed on the subject property at the proposed location of the new structure on the effective date of this Ordinance (Ordinance No. 06-013.) d. Demonstration that the placement of the proposed structure, if a mobile home, will not be located closer than ten (10) ft (3 m) side to side, eight (8) ft (2.4 m) end to side, or six (6) ft (1.8 m) end to end horizontally from any other mobile home, manufactured home, single family detached dwelling or community building unless the exposed composite walls and roof of either structure are without openings and constructed of materials that will provide a one -hour fire rating or the structures are separated by a one -hour fire -rated barrier. e. about:blank 4/25/2018 St. Lucie County, FL Land Development Code Page 5 of 5 Demonstration that the placement of the proposed structure, if an accessory structure, if located immediately adjacent to a site line is constructed entirely of materials that do not support combustion and provided that such buildings or structures are not less than three (3) ft (0.9 m) from an accessory building or structure on an adjacent site. An accessory building or structure constructed of combustible materials shall be located no closer than five (5) ft (1.5 m) from the site line of an adjoining site. f. The literal application of the provisions of the Code for required minimum yard setback will result in an undo hardship on the property owners and would otherwise prohibit the use of the petitioned property as others are used in the surrounding neighborhood. g. The variance requested will not result in any encroachment into any access/utility easement or other common area. h. The variance requested will not conflict with any other provision of this Code. 3. Conditions on Variances. The Building Code Administrator or his/her designee shall attach such conditions, limitations and requirements to the variance as are necessary to effectuate the purpose of this section. about:blank 4/25/2018