Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Agenda Packet 07.18.2024
PLANNING & ZONING COMMISSION AGENDA ST. LUCIE COUNTY Regular Meeting Thursday, July 18, 2024 6:00 PM St. Lucie County Commission Chambers 2300 Virginia Avenue 3rd Floor of Roger Poitras Building Fort Pierce, FL 34982 BOARD MEMBERS CHAIRMAN ED LOUNDS VICE-CHAIRMAN RYAN BINNER BOARD MEMBER CRAIG MUNDT BOARD MEMBER VALERIE SLACK BOARD MEMBER JAMES TAYLOR BOARD MEMBER WILLIAM O’DELL AT-LARGE BOARD MEMBER LARRY NEESE EX-OFFICIO BOARD MEMBER NICOLE FOGARTY Mission Statement St. Lucie Works to deliver superior service that enhances our quality of life Page 1 of 428 Regular Meeting Thursday, July 18, 2024 6:00 PM 2 | P a g e WELCOME • Please turn off all cellular phones and pagers prior to entering the Commission Chambers. • Please note that the Planning and Zoning Commission/Local Planning Agency serves in an advisory capacity to the St. Lucie County Board of County Commissioners and has the power to review and make recommendations to the Board, for approval or disapproval, on any applications within their area of responsibility. • The Planning and Zoning Commission strongly encourages your input and comment at the public hearing. Please limit comments to three minutes if possible and be respectful of others’ opinions. • For public convenience, all meetings are televised and are provided with wireless internet access. NOTICE: All Proceedings before this Board are electronically recorded. Any person who decides to appeal any action taken by the Board at these meetings will need a record of the proceedings and for such purpose may need to ensure that a verbatim record of the proceedings is made. Upon the request of any party to the proceedings, individuals testifying during a hearing will be sworn in. Any party to the proceedings will be granted the opportunity to cross-examine any individual testifying during a hearing upon request. Anyone with a disability requiring accommodation to attend this meeting should contact the Human Resources Department at (772) 462-1546, HumanResources@stlucieco.org or TDD (772) 462-1428 at least forty-eight (48) hours prior to the meeting. Page 2 of 428 Regular Meeting Thursday, July 18, 2024 6:00 PM 3 | P a g e 1. CALL TO ORDER 2. PLEDGE OF ALLEGIANCE 3. INVOCATION 4. ROLL CALL 5. ANNOUNCEMENTS 6. DISCLOSURE(S) 7. MINUTES A. St. Lucie County Planning & Zoning Commission minutes for the meeting of June 20, 2024. 8. PUBLIC COMMENT 9. PUBLIC HEARINGS A. FPL's Petition Text Amendments to the LDC (Land Development Code) Amending LDC Sec. 2.00.00 (Definitions), Sec. 3.01.01.D. (Zoning Districts, Generally, Public Services and Facilities), and Sec. 7.10.28.A (Solar Generation Station) Staff recommends the Planning & Zoning Commission review the proposed Land Development Code text amendment and forward a recommendation of approval to the Board of County Commissioners. B. DLF Citrus (FKA Sunbrite Citrus) Planned Non-Residential Development (PNRD) Rezoning & Preliminary Plan Staff recommends the Planning & Zoning Commission forward a recommendation of approval to the Board of County Commissioners, subject to conditions identified in the Draft Resolution enclosed. C. Walton Ranch Petition to Rezone from AR-1 (Agricultural, Residential-1) and RM-5 (Residential Multiple-Family-5) to PUD (Planned Unit Development) and approve a Preliminary Development Plan Page 3 of 428 Regular Meeting Thursday, July 18, 2024 6:00 PM 4 | P a g e D. O'Reilly's Auto Parts petition for a Conditional Use Permit to develop a retail auto parts store in the CN (Commercial Neighborhood) Zoning District E. TDC Holdings, LLC (Guettler Brothers Construction) Petition to Rezone a +/- 36 Acre Parcel on the west side of Sapp Road from the IX, Industrial Extraction Zoning District to the IL, Industrial Light (28.5 acres) and IH, Industrial Heavy (7.5 acres) zoning districts. 10. WORKSHOPS 11. OTHER BUSINESS 12. ADJOURN Page 4 of 428 PLANNING & ZONING COMMISSION ST. LUCIE COUNTY, FLORIDA Regular Meeting June 20, 2024 Convened:6:01pm Adjourned:10:44pm 1.CALL TO ORDER Chair Lounds calls to order at 6:01pm. 2.PLEDGE OF ALLEGIANCE Chair Lounds. 3.INVOCATION Commissioner O’Dell. 4.ROLL CALL Present Board Member Billy O'Dell, Board Member Craig Mundt, Chair Ed Lounds, Vice-Chair Ryan Binner, Board Member Valerie Slack, Board Member Larry Neese, Board Member James A. Taylor, Ex-Officio Board Member Nicole Fogarty Excused 5.ANNOUNCEMENTS Chair Lounds announced that agenda line item 9C would be going before agenda item line 9B. 6.DISCLOSURE(S) None. Page 5 of 428 Planning & Zoning Commission MeetingThursday, June 20, 2024 6:00 PM 2 | P a g e 7.MINUTES RESULT:APPROVE MOVER:Board Member Craig Mundt SECONDER:Board Member Billy O'Dell AYES:Billy O'Dell, Craig Mundt, Ed Lounds, Ryan Binner, Valerie Slack, Larry Neese, James A. Taylor NAYS:None EXCUSED:None A.St. Lucie County Planning & Zoning Commission minutes for the meeting of 5/16/2024. 8.PUBLIC COMMENT None. 9.PUBLIC HEARINGS A.ALTA Equipment Group - Conditional Use Permit to allow Heavy Construction Equipment Sales, Rental, and Leasing (SIC Code 7353) in the AG-1 (Agricultural - 1) Zoning District, located at 9901 Okeechobee Road, Fort Pierce, Florida 34935. - THIS ITEM IS QUASI-JUDICIAL STAFF PRESENTATION: Tahir Curry, Planner 1, with Planning and Development Services. Mr. Curry stated that all public notification requirements were met per St. Lucie County Development Code Section 11.00.03. Mr. Curry presented on a Conditional Use Permit to allow Heavy Construction Equipment Sales, Rental, and Leasing (SIC Code 7353) at 9901 Okeechobee Road, Fort Pierce, FL 34945, within the AG-1 (Agricultural - 1) Zoning District. Mr. Curry provided the board with information regarding ALTA Equipment Group request to include agricultural equipment along with heavy construction equipment. The previous use, Sunrise Tractor & Equipment, operated on a similar scale, operating a retail sales facility for farm equipment. Staff recommended the Planning & Zoning Commission forward a recommendation of approval to the Board of County Commissioners. BOARD DISCUSSION WITH STAFF: Commissioner Mundt inquired about the Creekside project. Mr. Benton, Planning Manager, answered the project is active and described the current state the development is in. Commissioner Slack asked for clarification on the approval by the Planning Director of heavy equipment as an eligible conditional use when it normally isn't a conditional use and was it a one-time event or is this a change to the LDC. Mr. Curry confirmed it was for this specific site. Page 6 of 428 Planning & Zoning Commission MeetingThursday, June 20, 2024 6:00 PM 3 | P a g e Chair Lounds asked Mr. Curry to elaborate on the wall waiver. Mr. Curry stated that neighbors had to approve the waiver or there would be a 8’ fence or wall. APPLICANT PRESENTATION: Leslie Olson, AICP, District Planning Group, representing Alta Equipment Group - 130 S Indian River Dr. Ste 202 Fort Pierce, FL 34950. Ms. Olson representing Alta Equipment Group presented the conditional use petition before the board. Ms. Olson’s presentation provided information for the board, on the location, background of the property, the current zoning and Alta Equipment Group’s proposal to sell and lease heavy equipment primarily for ground preparation, including land development, agricultural land preparation and management, light service of leased and sold equipment within the existing building, but excluings bodywork, painting, and other types of services that may impact the adjacent properties. BOARD DISCUSSION WITH APPLICANT: Commissioner Mundt inquired about the Creekside project approvals from neighbors. Ms. Olson confirmed that all neighbors approved. Commissioner Slack made a comment about lighting. Josh McDonald, Regional Director, Operations Alta Equipment Company came and elaborated on the lighting situation. Commissioner Mundt inquired on hours of operation and being open on Sunday. Vice-Chair Binner piggybacked on hour of operations regarding being open on Sunday. The discussion continued. PUBLIC COMMENTS: None. BOARD DISCUSSION: None. RESULT:APPROVE MOVER:Board Member Billy O'Dell SECONDER:Board Member Ryan Binner AYES:Billy O'Dell, Craig Mundt, Ed Lounds, Ryan Binner, Valerie Slack, Larry Neese, James A. Taylor NAYS:None EXCUSED:None Page 7 of 428 Planning & Zoning Commission MeetingThursday, June 20, 2024 6:00 PM 4 | P a g e C.Indrio & I-95 Planned Town or Village (PTV) - New (Modified) Preliminary (Regulating) Plan - THIS ITEM IS QUASI-JUDICIAL STAFF PRESENTATION: Irene Szedlmayer, AICP, Senior Planner, with Planning and Development Services. Ms. Szedlmayer stated that all public notification requirements were met per St Lucie County Development Code Section 11.00.03. Ms. Szedlmayer’s presentation provided information to the board regarding the background on Indrio & I-95 PTV (Planned Towns and Villages) Preliminary Development Plan, the revised PTV Preliminary Development Plan and its retention of a diverse mix of residential, commercial, and civic uses, a flow way, open space and countryside, and a walkable internal street network. The revisions to the PTV plan are being processed as a new Preliminary Development Plan due to requirements of the St. Lucie County Land Development Code. Staff recommended the Planning & Zoning Commission forward a recommended approval of the proposed PTV Preliminary Development Plan to the Board of County Commissioners. BOARD DISCUSSION WITH STAFF: Commissioner O’Dell asked for the current definition of workforce housing. Ms. Szedlmayer explained that the code provides for workforce housing and affordable housing, and the 8% of the residential units is mandatory, half must be so-called affordable housing and half can be workforce housing. Vice-Chair Binner asked staff what other civic sites are. Ms. Szedlmayer said that civic sites are defined quite broadly. It can be things like a school, a library, a fire station, a place of worship, but it can be a park, any kind of public space that is used by the public, basically. Conversation continues. Commissioner Fogarty voiced concerns regarding the relocation of the school and the allocated acreage. Chair Lounds inquired about the school and the fire station having access to Johnston Road. Ms. Szedlmayer answered yes. Commissioner Mundt questioned staff about what is on the other side of Johnston Rd. Ms. Szedlmayer stated it is open. Kori Benton Planning Manager added there is a Winery to the east. Page 8 of 428 Planning & Zoning Commission MeetingThursday, June 20, 2024 6:00 PM 5 | P a g e APPLICANT PRESENTATION: Kara Wood, with District Planning Group, 130 S. Indian River Drive, Suite 202 Fort Pierce, FL 34950. Ms. Wood used staff’s presentation as the visual to answer the board’s questions. Ms. Wood gave background on Indrio & I-95 PTV (Planned Towns and Villages) Preliminary Development Plan, the revised PTV Preliminary Development Plan retains a diverse mix of residential, commercial, and civic uses, a flow way, open space and countryside, and a walkable internal street network. Ms. Wood answered the board’s questions and asked the Planning and Zoning Commission to recommend approval, with conditions, of the proposed PUD and Preliminary Development Plan to the Board of County Commissioners. BOARD DISCUSSION WITH APPLICANT: Vice Chair Binner inquired about the housing units going down by 165 and workforce is going up by 390 and density increasing or decreasing. Ms. Wood explained that they are decreasing the unit count. Conversation continued. Commissioner Slack asked about the transferring of the development rights of the parcel and the two and a half multipliers. Ms. Wood, stated that the transfer of the development rights and the multipliers have not changed. PUBLIC COMMENTS: Matt Dietrich 4395 Johnston Road. Mr. Dietrich voices his concern regarding the school being relocated and his property now being in between the school and the fire department. Mr. Dietrich also mentioned the concern of traffic and noise. Commissioner Taylor inquired about the original location of the school. Ms. Szedlmayer pointed it out on the map. Chair Lounds asked if the school and the fire department could swap. Mr. Binner answered, the fire department has 2-acres and the school is 15-acres, and that would not work. Commissioner Fogarty comments on the neighbor that is now right between the proposed school and the fire station, the loss of acreage with the relocation of the school, and that they are willing to work with the applicant to figure this out. Ms. Wood stated that they are willing to work with the school and the neighbor to address all concerns. Conversation continues regarding the school relocation. Commissioner Taylor spoke on full access and changing the location of the school. Commissioner Slack asked the applicant if there would be enough acreage if you swapped the school site with the site just south of it that's on the west side of the site map. Marcella Page 9 of 428 Planning & Zoning Commission MeetingThursday, June 20, 2024 6:00 PM 6 | P a g e Camblor, town planner for the applicant spoke. Ms. Camblor states that they are willing to work with the school board and that the can figure out how to account for the missing three acres and that they moved it to the proposed location because the school requested to be near a road and further explains that it can be worked out. Commissioner Slack asked applicant what the plan was for Johnston Rd. Ms. Camblor replied this is in the existing comprehensive plan’s future street network and is slated to be a four- lane road. Conversation continues. BOARD DISCUSSION: Commissioner O’Dell is concerned that the neighbors’ concern was not addressed and wants to know what he would like to see done. Mr. Dietrich came back to the podium and stated that he would like to see the school moved. Commissioner Taylor asked the staff if an amendment could be added, stating that the road needs to be done before the school goes in. Mr. Benton explained the challenges with that type of approach. One, who would be responsible for building it and whether the traffic analysis supports and facilitates it. Conversation continued. RESULT:APPROVE MOVER:Board Member Valerie Slack SECONDER:Board Member Billy O'Dell AYES:Billy O'Dell, Craig Mundt, Ed Lounds, Ryan Binner, Valerie Slack, Larry Neese, James A. Taylor NAYS:None EXCUSED:None B.NVR Ryan Homes PUD Rezoning & Preliminary Planned Development Plan - THIS ITEM IS QUASI- JUDICIAL STAFF PRESENTATION: Thad Crowe, AICP, Senior Planner, with Planning and Development Services. Mr. Crowe stated that all public notification requirements were met per St Lucie County Development Code Section 11.00.03. Mr. Crowe presented the Zoning Atlas Amendment from AG-1 (Agricultural- 1) to PUD (Planned Unit Development) and a Preliminary Planned Development Plan, for the purpose of developing a residential community containing 219 single-family detached lots, 339 townhome lots, stormwater ponds, amenity center, and a preserve. Mr. Crowe’s presentation also included information regarding landscaping, site map, and staff recommendation. Staff recommended Page 10 of 428 Planning & Zoning Commission MeetingThursday, June 20, 2024 6:00 PM 7 | P a g e the Planning and Zoning Commission recommend approval, with conditions, of the proposed PUD and Preliminary Development Plan to the Board of County Commissioners. BOARD DISCUSSION WITH STAFF: Vice-Chair Binner inquired about the arterial road being connected to FFA road and the proposed bridge over the FL Turnpike. Kori Benton, Planning Manager, provided a detailed description of the proposal and provide a visual requested by Chair Lounds. The discussion continued regarding the proposed bridge, connecting streets, capital improvement plan, traffic reports, and impact fees and credits. Commissioner Slack questioned staff about the road quality and bringing on more traffic. Mr. Benton stated that improvements are slowly being made. Discussion continues. Chair Lounds inquired about a time frame for the project. Mr. Benton responsed, 15 to 20 plus years. Commissioner Slack asked if the zoning was AG-1. Mr. Benton confirmed that it is. Conversation continued, regarding height of the flyover for the bridge. Mr. Benton allowed representatives from our public works team to answer. Grant Chambers, Senior Project Engineer with St Lucie County Public Works and Engineering Department. Mr. Chambers stated that at this time that would be very preliminary to say. We have no design for the bridge. Discussion continues. Commissioner Slack asked the height limitation on townhomes. Mr. Benton explained that the height allowance can be set at the time of PUD. These are projected to be two-story townhomes. I would suggest they're probably in the ballpark between 23 and 28 feet. Conversation continues. APPLICANT PRESENTATION: Dan Sorrow with the land planning firm of Cotleur and Hearing. Mr. Sorrow introduced his team. Mr. Sorrow gave a presentation on the proposed Zoning Atlas Amendment from AG-1 (Agricultural-1) to PUD (Planned Unit Development) and a Preliminary Planned Development Plan, for the purpose of developing a residential community containing 219 single-family detached lots, 339 townhome lots, stormwater ponds, amenity center, and a preserve and asked the Planning and Zoning Commission recommend approval, with conditions, of the proposed PUD and Preliminary Development Plan to the Board of County Commissioners. BOARD DISCUSSION WITH APPLICANT: Commissioner O’Dell asked the applicant if property acquisition within 180 would be acceptable. Mr. Sorrow welcomed that recommendation. Mr. Benton read code section 7.05.03.I(4) where it prescribes the 90-day timeline or prior to building permit and that administrative extensions have been granted. Page 11 of 428 Planning & Zoning Commission MeetingThursday, June 20, 2024 6:00 PM 8 | P a g e Vice Chair Binner asked staff if the county gets the dedication for that land and you don't build arterial A, what will happen. Mr. Benton stated if dedicated for roadway purposes and in the future, the county makes it clear they would not construct the roadway, the applicant could petition abandonment. Discussion continued. Commissioner Slack commented on lot size and suggested that if we are going to have little lots, make smaller homes and a better street scape for the town homes. Mr. Sorrow stated that the rear of the units face the lake areas, which are more desirable than facing the street. Discussion continued. Chair Lounds asked Mr. Sorrow for visual of the overview of the development, Chair Lounds continues with you cannot put a house on a 40-foot lot that will return taxes over the period of that house to offset the services that that development will have from the county. Discussion continues regarding lot size and buffers, traffic, and density. Vice-Chair Binner asked the applicant if the property set back enough to make a left turn lane into the property. Mr. Sorrow stated yes. PUBLIC COMMENTS: Chet Moseley, 11401 W Angle Rd. Mr. Moseley is concerned about the noise and the traffic, and people looking into his backyard. Mr. Sorrow said they will work with Mr. Moseley regarding his concerns. BOARD DISCUSSION: Commissioner Taylor asked about calculation with the line of sight with having a two-story structure adjacent to a one story. Mr. Benton stated that the county has within our land development code what's called the building spacing formula. That formula traditionally applies to developments of two floors or greater. Commissioner Slack suggested that less than six units make up a townhome building and that there is some connection between the townhomes and the single-family homes, so the townhome residents don’t have to drive to the amenity parcel. Chair Lounds addressed the applicant regarding access to Old FFA and green space. Mr. Sorrow stated that is the plan for the Old FFA and there are green space and sidewalks. Conversation continues, Ms. Slack voices concern of safety under the arterial. RESULT:APPROVE MOVER:Board Member Billy O'Dell SECONDER:Board Member Ryan Binner AYES:Billy O'Dell, Craig Mundt, Ryan Binner, Larry Neese, James A. Taylor NAYS:Ed Lounds, Valerie Slack EXCUSED:None Page 12 of 428 Planning & Zoning Commission MeetingThursday, June 20, 2024 6:00 PM 9 | P a g e D.Neill Farm Estates Future Land Use Map Amendment STAFF PRESENTATION: Irene Szedlmayer, AICP, Senior Planner, with Planning and Development Services. Ms. Szedlmayer stated that all public notification requirements were met per St Lucie County Development Code Section 11.00.03. Ms. Szedlmayer presentation provided information to the board regarding the proposal of Future Land Use Map Amendment from AG-5 (Agricultural-5) to MXD (Mixed Use District) along with sub-area policies to permit residential development at 3 dwelling units per acre. Ms. Szedlmayer provided information on the current zoning, the proposed zoning, the proposed future land use, preliminary development plan, site map, and staff recommendations. Staff recommended that the Planning and Zoning Commission recommend that the Board of County Commissioners transmit the proposed amendment of the Future Land Use Map to the State Land Planning Agency. BOARD DISCUSSION WITH STAFF: Commissioner O’Dell asked about enforcing the 55 plus restriction. Ms. Szedlmayer there's an exemption or an exception to the Fair Housing Act. Commissioner Slack inquired about the designation being mixed use. Ms. Szedlmayer explained how staff did not think that it was appropriate to recommend RU, which allows for 5 dwelling units per acre in this location. Conversation continued. APPLICANT PRESENTATION: Lee Dobbins, Esq. with the Dean Mead Law Firm Fort Pierce. Mr. Dobbins gave a presentation on behalf of G.L. Acquisitions Corporation, giving background on the company and the proposed Land Use Map Amendment. Mr. Dobbins presentation contacted information Future Land Use Map Amendment from AG-5 (Agricultural-5) to MXD (Mixed Use District) along with sub-area policies to permit residential development at 3 dwelling units per acre. Ms. Szedlmayer provided information on the current zoning, the proposed zoning, the proposed future land use, preliminary development plan, site map, and recommendations for approval from the board. BOARD DISCUSSION WITH APPLICANT: Chair Lounds asked about the connection between this property and Palermo Estates to the north. Mr. Dobbins said yes. Commissioner Slack questioned will you plan to address the interaction between Neill Farms and Treasure Coast Airpark with the air traffic and does that impact your development. Mr. Dobbins answered, “I don’t know that the air traffic will impact us.” Leslie Olson, District Planning Group. Riverland Kennedy just to the east are close to that airpark and provides disclosures and they haven't had any issues. Page 13 of 428 Planning & Zoning Commission MeetingThursday, June 20, 2024 6:00 PM 10 | P a g e PUBLIC COMMENTS: Sofia Trail with the City of Port St Lucie Planning & Zoning Department. Ms. Trail read a letter sent to the St. Lucie County Planning Department, stating that the City is not in favor of this project, and they do not want the traffic to spill onto City roads. Conversation continues. BOARD DISCUSSION: None. Comment from Commissioner Taylor it would be nice to see the City and the County working together. RESULT:APPROVE MOVER:Board Member James A. Taylor SECONDER:Board Member Craig Mundt AYES:Billy O'Dell, Craig Mundt, Ed Lounds, Ryan Binner, Valerie Slack, Larry Neese, James A. Taylor NAYS:None EXCUSED:None 10.WORKSHOPS None. 11.OTHER BUSINESS None. 12.ADJOURN There being no further business to be brought before the Board, the meeting was adjourned at 10:44pm. Page 14 of 428 9.A. 2023-62189 PUBLIC HEARINGS - PLANNING & DEVELOPMENT SERVICES AGENDA REQUEST DATE: 7/18/2024 *ORDINANCE ITEM - LAND DEVELOPMENT CODE TEXT AMENDMENT QUASI-JUDICIAL ITEM? No TO: Board of County Commissioners PRESENTED BY: Thad Crowe, Senior Planner SUBMITTED BY: Planning & Development Services SUBJECT: FPL's Petition Text Amendments to the LDC (Land Development Code) Amending LDC Sec. 2.00.00 (Definitions), Sec. 3.01.01.D. (Zoning Districts, Generally, Public Services and Facilities), and Sec. 7.10.28.A (Solar Generation Station) BACKGROUND: The Applicant, Florida Power & Light, and representative, Dennis Murphy of Culpepper & Terpening, initiated the following Text Amendments to the St. Lucie County Land Development Code (LDC) to: 1. Amend Sec. 2.00.00 (Definitions): to revise the Essential Utility Service Facilities and Solar Generation Station definitions and add a new definition for Electric Substation. 2. Amend Sec. 3.01.01.D. (Zoning Districts, Generally, Public Services and Facilities) to: - harmonize with statutory language [F.S. 163.3208.(4)] that regulates setbacks and landscape buffers for Electric Substations; - to not include screening walls and fencing in the calculation of square footage for an Essential Utility Service Facilities building or structure; and - to remove the word “distribution” from “distribution substations.” 3. Amend Sec. 7.10.28. (Supplemental Standards, Solar Generation Station) to: - add the North St. Lucie River Water Control District and Ft. Pierce Farms Water Control District Canals or Rights of Way as owners of canals adjacent to new Solar Generation Stations, canals that with this change would not activate the perimeter buffer requirement for the solar station property; and - exempt new solar generation station applications from including written legal descriptions of Class III wetlands, the continued graphic depiction of Class III wetlands by qualified wetland experts will still be required. PREVIOUS ACTION: Regulations pertaining to Electric Substations were adopted in 2012 and have not been amended since then. Regulations pertaining to Solar Generation Stations were adopted in 2010 and were amended twice after Page 15 of 428 that, as noted below. In 2022, the County adopted an ordinance to reflect state legislation that allowed solar facilities as permitted uses in all agricultural land use categories in a local government comprehensive plan, complying with setback and landscape buffer area criteria for similar uses in agricultural zoning districts. In 2023, the County adopted another ordinance exempting parcels on which Solar Generation Stations are located from meeting minimum frontage standards, which allowed the use of isolated properties that had access to, but less of a presence on roads. The ordinance also exempted the subdivision or redivision of solar generation sites from the platting requirements. FINANCIAL IMPACT: No fiscal impact identified. RECOMMENDATION: Staff recommends the Planning & Zoning Commission review the proposed Land Development Code text amendment and forward a recommendation of approval to the Board of County Commissioners. COMMISSION ACTION: RESULT: MOVER: None SECONDER: None AYES: None NAYS: None EXCUSED: None Coordination/Signatures Date: July 12, 2024 Benjamin Balcer, Planning & Development Services Director Date: July 12, 2024 Katherine Barbieri, Assistant County Attorney III Date: July 12, 2024 Mayte Santamaria, Deputy County Administrator Page 16 of 428 Planning and Development Services Department Planning Division M E M O R A N D U M TO: THROUGH: FROM: DATE: SUBJECT: Planning and Zoning Commission Benjamin Balcer, AICP, Planning & Development Services Director Kori Benton, AICP, Planning Manager Thad Crowe, AICP, Senior Planner July 1, 2024 Electric Substation and Solar Generation Station-Related Text Amendments to the Land Development Code Amending LDC Sec. 2.00.00 (Definitions), Sec. 3.00.01.D. (Zoning Districts, Public Services and Facilities), and Sec. 7.10.28.A (Solar Generation Station) - TLDC-2401-000033 GENERAL INFORMATION: Applicant:Florida Power & Light c/o Mitchell Heaton 700 Universe Blvd. Juno Beach, FL 33408 Agent:Dennis Murphy Culpepper & Terpening, Inc. 2980 S. 25th St. Fort Pierce, FL 34981 BACKGROUND Florida Power & Light has applied for several text amendments to the Land Development Code (LDC). The proposed changes to Electric Substation and Solar Generation Station guidelines, are summarized below and then analyzed. 1. Amend Sec. 2.00.00 (Definitions): to revise the Essential Utility Service Facilities and Solar Generation Station definitions and add a new definition for Electric Substation. 2. Amend Sec. 3.01.01.D. (Zoning Districts, Generally, Public Services and Facilities): to harmonize with statutory language [F.S. 163.3208.(4)] that regulates setbacks and landscape buffers for Electric Substations. 3. Amend Sec. 3.01.01.D. (Zoning Districts, Generally, Public Services and Facilities): to not include screening walls and fencing in the calculation of square footage for an Essential Utility Service Facilities building or structure. 4. Amend Sec. 3.01.01.D. (Zoning Districts, Generally, Public Services and Facilities), removing the word “distribution” from “distribution substations.” 5. Amend Sec. 7.10.28. (Supplemental Standards, Solar Generation Station), to add the North St. Lucie River Water Control District and Ft. Pierce Farms Water Control District Canals or Rights of Way as owners of canals adjacent to new Solar Generation Stations which don't activate the perimeter buffer requirement for the solar property. 6. Amend Sec. 7.10.28. (Supplemental Standards, Solar Generation Station): to exempt new solar generation station applications from including written legal descriptions of Class (Category) III wetlands, the continued graphic depiction of Class III wetlands by qualified wetland experts will still be required. Page 17 of 428 Project Name: Electric Substation and Solar Generation Station LDC Text Amendment File No.: TLDC-2401-000033 2 1. Definition Revisions The Text Amendment would revise two definitions to reflect statutory changes, and the Applicant proposed a new definition (below) which also reflects statutory language. Electric Substations and Solar Generation stations are separate and distinct facilities. Electric Substation: An electric substation is a use, including accessory administration or maintenance buildings and related accessory uses and structures, which takes electricity from the transmission grid and converts it to another voltage or a lower voltage so it can be distributed to customers through one or more lines. The proposed definition revision below then adds the new use of electric substations to the list of Essential Utility Service Facilities. Essential Utility Service Facilities: Small scale infrastructure improvements located outside transportation and utility rights-of-way that support the provision of public facilities and services and are required to be located in or near the neighborhood where the service is provided, including improvements that support the transmission or distribution systems of water, sanitary or storm sewage, cable, gas, electricity, and public safety, including poles, wires, mains, hydrants, drains, sewer lift stations, electric substations, pipes, conduits, police or fire call boxes, warning sirens, bus stops, stormwater retention or detention facilities, chloramine injection station, potable water booster station and other similar equipment necessary for the furnishing of adequate public service. The second definition revision adds energy storage equipment (batteries) and administrative and support facilities as elements of a Solar Generation Station. Solar Generation Station: An energy generation facility comprised of one (1) or more freestanding, ground mounted photovoltaic modules or devices that capture solar energy, converts it to electrical energy, stores energy, or delivers energy to a transmission system for use in locations other than where it is generated. Solar generation stations typically utilize photovoltaic solar cells, but can also be combinations of light reflectors, concentrators, energy storage equipment, and heat exchangers. A Solar Generation Station is also known as a solar facility, solar plant, solar generation plant, solar farm, solar power plant, battery storage plant, energy storage plant or solar thermal power plant. Ground mounted solar devices that capture solar energy (panels) shall not count towards maximum lot coverage. A Solar Generation Station may include, as an accessory use to the operation of the Station, administrative and maintenance support facilities. 2. Setbacks and Buffers The Applicant proposes the following changes. a. Essential Utility Service Facilities parcels shall be exempt from the lot width, lot size and road frontage requirements but all improvements on a parcel or parcels shall meet the maximum height requirements and all buildings and structures shall also meet the setback requirements of the zoning district in which they are located, unless otherwise exempted regulated under Section 163.3208, Florida Statutes. The improvements shall comply with all resource protection and development standards for vegetation protection, protection of environmentally sensitive lands, protection of habitat for endangered and threatened species, flood damage prevention and stormwater management. In addition, above ground mechanical improvements located outside the right-of-way and adjacent to residentially zoned property and road rights-of-way shall be screened by landscaping with the type and location of the improvement and landscape treatments to be determined at the time of permitting. Page 18 of 428 Project Name: Electric Substation and Solar Generation Station LDC Text Amendment File No.: TLDC-2401-000033 3 Florida Statute 163.3208 addresses multiple aspects of Electric Substations. Staff is recommending replacing the LDC word “exempted” with “regulated” in the Electric Substation definition due to the fact that F.S. 163.3208. provides limited exemptions, with local governments still allowed to broadly apply landscape and buffering standards to substations. The statute exempts requirements for shade trees with a standard not requiring mature vegetation height over 14 feet under aerial access points and requires eight-foot-tall fences or walls in setbacks/landscape buffers under 50 feet in width (50- to 100-foot-wide buffers require a fence, height not specified). Local landscaping, buffering, and screening standards remain in force, and a local government can establish substation setbacks not to exceed 100 feet. The relevant Statute subsections are below. F.S. 163.3208(3): Electric substations are a critical component of electric transmission and distribution. Except for substations in s. 163.3205(2)(c), local governments may adopt and enforce reasonable land development regulations for new and existing electric substations, addressing only setback, landscaping, buffering, screening, lighting, and other aesthetic compatibility-based standards. Vegetated buffers or screening beneath aerial access points to the substation equipment shall not be required to have a mature height in excess of 14 feet. F.S. 163.3208(4): New and existing electric substations shall be a permitted use in all land use categories in the applicable local government comprehensive plan and zoning districts within a utility’s service territory except those designated as preservation, conservation, or historic preservation on the future land use map or duly adopted ordinance. If a local government has not adopted reasonable standards for substation siting in accordance with subsection (3), the following standards shall apply to new electric substations: (a) In nonresidential areas, the substation must comply with the setback and landscaped buffer area criteria applicable to other similar uses in that district, if any. (b) Unless the local government approves a lesser setback or landscape requirement, in residential areas, a setback of up to 100 feet between the substation property boundary and permanent equipment structures shall be maintained as follows: 1. For setbacks between 100 feet and 50 feet, an open green space shall be formed by installing native landscaping, including trees and shrub material, consistent with the relevant local government’s land development regulations. Substation equipment shall be protected by a security fence consistent with the relevant local government’s land development regulations. 2. For setbacks of less than 50 feet, a buffer wall 8 feet high or a fence 8 feet high with native landscaping consistent with the relevant local government’s regulations shall be installed around the substation. 3. Exclusion of Walls and Fences From Calculation of Essential Utility Service Buildings or Structures The Applicant has proposed Sec. 3.01.01.D.2.b.4, shown below, as a new subsection. This is not a statutory- based change. The change would not require screening or security fences or walls to be included in calculating the size of structures. Subsection b.1. below limits locations of Essential Utility Service Facilities structures larger than 300 square feet to zoning districts where they are a permitted, conditional, or accessory use, while neighborhood-scale structures smaller than 300 square feet are allowed regardless of the zoning. Staff has no objection to this addition since a fence and wall used in the context of buffering and screening should not be used for, or considered to be, walls of a structure. b. Essential Utility Service Facilities involving buildings or structures that shield the infrastructure for aesthetic purposes or that provide storage incidental to the Essential Utility Service shall be permitted upon a demonstration of compliance with all applicable sections of this Code, and the provisions below: 1)The cumulative area of the Essential Utility Service Facilities building or structure shall not exceed 300 square feet. Essential Utility Service Facilities involving buildings or structures with a cumulative Page 19 of 428 Project Name: Electric Substation and Solar Generation Station LDC Text Amendment File No.: TLDC-2401-000033 4 total area larger than 300 square feet, or not compliant with this Section, shall only be permitted within a zoning district when specifically listed as a permitted, conditional or accessory use. 2)The Essential Utility Service Facilities building or structure shall comply with all applicable building codes, resource protection and development design standards, including landscaping and screening requirements. Where necessary, the Planning and Development Services Director may approve alternative plans for security purposes or to ensure compatibility with the surrounding zoning district and existing uses. 3)Within residentially zoned areas, Essential Utility Service Facilities buildings or structures shall require approval by the Planning and Development Services Director. The Director shall deny any building or structure that would likely create an adverse impact on neighboring properties. 4) For the purpose of this section, an opaque screening wall or fence, erected or constructed for the purpose of screening or providing security to an Essential Utility Service Facility shall not be included in the 300 square foot limitation cited in Paragraph 1 above. All screening walls or fences shall be subject to applicable local height and site distance placement requirements. 4. Remove “Distribution” as Qualifier for “Substation.” In Sec. 3.01.01.D.3 (Zoning Districts, Public Services and Facilities): in following passage, remove the word “distribution” from “distribution substations.” Distribution is a superfluous term in this case since by their nature, substations convert and distribute energy. Staff has no objection to this revision. 3.Public services and facilities not meeting the provisions for Transportation and Utility Rights-of-way or Essential Utility Service Facilities, including but not limited to those involving distribution substations, generation plants, treatment plants, or stormwater pumping stations shall be permitted within zoning districts only when listed as a permitted or conditional use. Where an Essential Utility Service Facilities improvement is specifically addressed in another section of this Code, and conflicts with this Section, the most restrictive requirements shall apply. 5. Add Specific Water Control Districts as Landowners of Canals That Don’t Require Perimeter Buffers on Adjacent Lands Being Developed. Sec. 7.10.28. (Supplemental Standards, Solar Generation Station): Sec. 7.10.28.A.1.b)3. does not require perimeter landscape buffers for new Solar Generation Stations when there is an intervening public right-of- way or a South Florida Water Management District Canal. The Applicant proposes to add the North St. Lucie River Water Control District and Ft. Pierce Farms Water Control District Canals or Rights of Way to the exemption. This section also sets the lesser of a 25-foot setback or underlying Ag setbacks. New language is below. b) In Zoning Districts in which a Minor Site Plan application is required the development shall be subject to the following supplemental criteria: 1. Physical access to a Solar Generation Station may be restricted by fencing or walls. Razor wire is prohibited. All fencing and wall details shall be provided for review and approval as part of the required site plan. 2. The devices that capture energy and convert it to electricity shall not be placed in wetlands, environmentally sensitive resources or habitats, imperiled and critically imperiled habitats as defined by the Florida Natural Areas Inventory, and/or buffers: Any environmental impacts from such devices, or any component of a Solar Generation Station, shall only be allowed in compliance with the provisions of the County's Comprehensive Plan and Land Development Code. 3. All devices that capture and convert energy to electricity shall comply with the setback regulations of the underlying Agricultural Zoning District, or provide a 25-foot setback from all perimeter lot or parcel lines, whichever is less. Page 20 of 428 Project Name: Electric Substation and Solar Generation Station LDC Text Amendment File No.: TLDC-2401-000033 5 4. Perimeter buffers and landscaping requirements are only required for property lines that are directly adjacent to established residential uses and which are not separated by a public right-of-way, South Florida Water Management District Canal, North St. Lucie River Water Control District, or Ft. Pierce Farms Water Control District Canals or Rights of Way. When a Solar Generation Station is adjacent to a non-agricultural zoning district the buffer and landscape requirements for the underlying agricultural zoning district shall apply. The perimeter buffer landscaping requirements may be waived by the Board of County Commissioners, if it is shown to the satisfaction of the Commission that the adjoining property owners from the nonagricultural zoning district property have no objection to the landscaping requirement being waived. 5. On-site power lines shall be placed underground to the maximum extent possible. 6. The paving requirements within Section 7.05.07(B) shall not apply to Solar Generation Station that utilize unpaved public or private roads and roadways for access. 7. The minimum frontage requirement for a Solar Generation Station in the AG-5, AG-2.5 or AG-1 Zoning District is zero (0) feet, provided legal and sufficient ingress and egress to the facility is demonstrated to the satisfaction of the County Attorney, the County Engineer and the Planning and Development Services Director. Where such access to a Solar Generation Station site relies upon an easement, easements, or any interest in land that is less than fee simple ownership, the Final Development Order granting Minor Site Plan approval and the Site Plan shall identify the Book and Page where such easement or other right of access is recorded in the Official Records of St. Lucie County. The Development Order and the Site Plan shall contain the following statement: "NEITHER ST. LUCIE COUNTY NOR ANY OTHER GOVERNMENTAL OR PUBLIC AGENCY IS RESPONSIBLE FOR THE MAINTENANCE, UPKEEP OR IMPROVEMENT OF ANY PRIVATE DRIVES, ROADS, STREETS, EASEMENTS, OR RIGHTS-OF-WAY PROVIDING INGRESS AND EGRESS OR DRAINAGE SERVICE TO THE PROPERTY THAT IS THE SUBJECT OF THIS DEVELOPMENT ORDER.” 6. Allow for Graphic Representation of Class (Category) III Wetlands without Written Legal. Category III wetlands (isolated wetlands less than 5 acres that are not the more prime Category I or II wetlands) must now be shown on Solar Generation Station site plan after being flagged by a qualified wetland expert, and must also be referenced in the written legal description. This change would remove the written legal description requirement. Staff has no objection to this revision. ERD provided the following insight into this proposed change. The applicant’s reasoning for this proposed change is multifaceted but relates to the viability of small low quality isolated man-made wetlands located along historic agriculture furrows and their relation to the viability of development or sale of the property in the far future. Ultimately, the Category III Wetlands will still be protected and preserved throughout the life of the solar energy development, but by the utilization of different instrumentation that mimics a time-restricted CE and PAMMP (Preserve Area Management and Monitoring Plan). A traditional PAMMP shall still be required for Category I and II Wetlands for all development types, and for Category III Wetlands for solar energy developments that require a Major Site Plan. The proposed new language is below. 6. Surveys for Solar Generation Stations shall be compliant with the requirements of Section 11.02.09(A)(2)(d), except that any Category III wetlands, as defined by the St Lucie County Comprehensive Plan, that are located on the site need only be graphically located on the project site plan, provided that they have been identified with field flagging or by GPS (or equivalent) coordinate mapping, by a qualified Page 21 of 428 Project Name: Electric Substation and Solar Generation Station LDC Text Amendment File No.: TLDC-2401-000033 6 Professional Wetland Scientist (PWS). All such wetlands are to be buffered in accord with the County’s Comprehensive Plan, unless otherwise proposed for alteration or impact. Figure 1: Loggerhead Solar Center: +/-569-acre site located west of the intersection of Glades Cut Off & Carlton Roads - Example Site Page 22 of 428 Project Name: Electric Substation and Solar Generation Station LDC Text Amendment File No.: TLDC-2401-000033 7 ************************************************************************* Pursuant to St. Lucie County Land Development Code (LDC) Section 11.06.03, the Development Review Committee (DRC) has reviewed the proposed Text Amendment and found it to meet the technical requirements and standards of review set forth for LDC amendments. In reviewing the proposed Amendment, the Planning and Zoning Commission shall consider and make the following determinations: A. Whether the proposed amendment is in conflict with any applicable portions of the St. Lucie County Land Development Code; Two of the amendments provide local consistency with applicable Florida Statutes governing electric and solar facilities, and the other proposed amendments seek to clarify current LDC elements. B. Whether the proposed amendment is in conflict with all elements of the St. Lucie County Comprehensive Plan; The County’s Comprehensive Plan sets objectives and policies that are very supportive of solar energy utilization and generation. The Future Land Use Element includes a green building objective with related policies of reviewing the LDC and considering appropriate standards for use of renewable energy sources, including solar panels (Policy 1.4.2.4), and facilitating low-interest loans through the Solar and Energy Loan Fund (SELF) to residents and business owners for installing renewable energy technology as well as energy efficiency and conservation measures (Policy 1.4.2.5). The Housing Element includes an objective of supporting energy efficiency and renewable energy resource use in new and existing housing (Objective 3.2.7), with supporting policies of encouraging green building practices, which include solar energy (Policies 3.2.7.1 & 3.2.7.6), not prohibiting and establishing standards for appropriate placement of solar panels (Policy 3.2.7.3), including renewable energy resources in affordable housing projects to the fullest extent possible (Policy 3.2.7.7), and facilitating low-interest loans through the county's Solar and Energy Loan Fund to residents and business owners for installing renewable energy technology as well as energy efficiency and conservation measures (Policy 3.2.7.10). The County lists solar energy as a targeted clean energy industry for economic development programming in the Economic Development Element. This space intentionally left blank TEXT AMENDMENT STANDARDS OF REVIEW AS SET FORTH IN SECTION 11.06.03, ST. LUCIE COUNTY LAND DEVELOPMENT CODE Page 23 of 428 Project Name: Electric Substation and Solar Generation Station LDC Text Amendment File No.: TLDC-2401-000033 8 Figure 2: Cumulative U.S. Solar Installations Source: SEIA/Wood Mackenzie Power & Renewables U.S. Solar Market Insight Q2 2024 CSP is Concentrated Solar Power As indicated in Figures 2 & 3, solar energy has experienced rapid growth in the U.S. in recent years, with an average annual growth of 25% in installations in the last decade and 264% solar workforce growth since 2010. In Florida, the current average cost for a 5 kW solar panel system is around $11,812. Once the 30% federal tax credit for solar equipment is factored in, the cost of a solar panel system in Florida comes down to $8,268. Homeowners can also take advantage of state and local incentives including a full County sales and property tax exemption on solar equipment. Homeowners can now save money on their electricity bills over time, potentially breaking even in a decade or less. Figure 3: Cumulative U.S. Solar Installations Source: National Solar Jobs Census 2022 Page 24 of 428 Project Name: Electric Substation and Solar Generation Station LDC Text Amendment File No.: TLDC-2401-000033 9 In recent years FP&L has opened six (6) solar generation stations in St. Lucie County and plans for an additional ten (10) as noted below. Figure 4 shows station locations. Existing Solar Generation Stations • Interstate Solar Generation Station, located on Indrio Road west of Interstate 95 – 1211-111-0001-000-9 & 1214-111-0001-000-8. • Loggerhead Solar Generation Station, off Glades Cut Off Rd. at the Martin County line – 4221-312-0040- 000-1 • Pelican Solar Generation Station, south of the Indian River County line and north of the Turnpike, in the western County – 1206-501-0017-000-5. •Sundew Solar Generation Station, west of the intersection of Glades Cut Off Rd. and Carlton Rd. at the Martin County line – 4217-601-0005-000-8, 4217-601-0007-000-2, 4217-601-0006-000-5, 4217-122- 0001-000-0, 4217-111-0002-000-3. • Pink Trail Solar Generation Station, west of Glades Cut Off Rd.– 3233-122- 0015-000-8. • Bluefield Solar Generation Station – 4119-111-0001-000-5, located east of the Okeechobee County line, south of SR70. Approved, Unbuilt Solar Generation Stations • North Orange Solar Generation Station, in the northwest corner of the County – 1206-501-0003-000-4. • Orchard Solar Generation Station, also in the northwest corner of the County – 1206-501-0017-000-5. •Wood Stork Solar Generation Station – 1107-111-0001-000-9 & 1108-212-0001-000-2. Solar Generation Stations Under Review •Buttonwood Solar Generation Center, western County, south side of Turnpike, one mile east of Okeechobee Co. Line - 1106-111-0001-000-6 & 2105-111-0001-010-9. •Pine Lily Solar Generation Station, western County, north of Orange Ave. – 1117-212-0001-000-0 & 1107- 111-0001-000-9. • Spanish Moss Solar Generation Station, also western County, north of Orange Ave. – 1206-501-0003-000- 4. Upcoming Solar Generation Stations •Clover Solar Generation Station, east of Minute Maid Rd. & south of Turnpike – 1233-122-0015-000-2. •Indrio Solar Generation Station, north of Indrio Rd., west of I-95 – 1215-121-0001-000-2 •Waveland Solar Generation Station, east of Minute Maid Rd. at Indian River Co. Line - 1203-121-0001- 000-5 •Wild Lime Solar Generation Station, unknown location. FP&L's solar plants use only sunshine for power and don't create greenhouse gas emissions. FP&L's goal is to eliminate carbon emissions from its power plants by 2045. FP&L representatives have told Staff that St. Lucie County is their most active county in the state for existing and planned solar power generation. Page 25 of 428 Project Name: Electric Substation and Solar Generation Station LDC Text Amendment File No.: TLDC-2401-000033 10 Figure 4: Solar Generation Stations Map – St. Lucie County Page 26 of 428 Project Name: Electric Substation and Solar Generation Station LDC Text Amendment File No.: TLDC-2401-000033 11 Staff believes that the amendment is in keeping with the following Comprehensive Plan goals, objectives, and policies. Future Land Use Element Goal 1.4: Ensure through the Comprehensive Plan the development of energy efficient land use patterns and policies that reduce greenhouse gas emissions through innovative sustainable land planning tools which discourage urban sprawl, protect native habitat, reduce automobile use, and maintain open space. Objective 1.4.1: Create a sustainable plan for the County's western lands that will preserve and conserve a functioning network of agriculture, open space, and natural areas while providing economically viable options for agricultural landowners, now and in the future based upon the Western Lands Study. Policy 1.4.2.4 –The Land Development Code shall maintain appropriate standards for use of alternate, renewable sources of energy including the use of solar panels except in environmentally sensitive areas. The standards are intended to facilitate the commercial generation and distribution of solar power and the use of on-site solar energy systems to meet the energy demands of buildings and support facilities in the unincorporated County. The County shall review the Land Development Code and consider appropriate standards for the use of other renewable sources. Policy 1.4.2.5 - The County shall facilitate the creation of low interest loans through the Solar and Energy Loan Fund to residents and business owners to install energy efficiency and conservation measures as well as renewable energy technology. Goal 10.2: Diversify the year-round economy and established an economic and cultural climate that will allow St. Lucie County to effectively compete in the global economy. Objective 10.2.2: Establish procedures and tools to encourage business development and assist economic development in St. Lucie County. Policy 10.2.1.4 - Encourage the development of clusters of industries according to the adopted targeted industry list such as Manufacturing Facilities, Finance and Insurance, Information, Clean Energy, Professional, Scientific, and Technical Services, Management and Distribution, and Administrative and Support Services at appropriate locations in St. Lucie County. Objective 3.2.7: The County shall support energy efficiency and the use of renewable energy resources in existing housing and in the design and construction of new housing. Policy 3.2.7.1 - The County shall encourage support for residential construction that meets the United States Green Building Council (USGBC) Leadership in Energy and Environmental Design (LEED) rating system or the Florida Green Building Coalition standards. Policy 3.2.7.3 - The County shall not prohibit the appropriate placement of photovoltaic panels. The County shall develop and adopt review criteria to establish the standards for the appropriate placement of photovoltaic panels. Page 27 of 428 Project Name: Electric Substation and Solar Generation Station LDC Text Amendment File No.: TLDC-2401-000033 12 Policy 3.2.7.6 - The County shall require in all rehabilitation and replacement projects use of green, energy efficient materials as appropriate. Policy 3.2.7.10 - The County shall facilitate the creation of low interest loans to residents and business owners to install energy efficiency and conservation measures as well as renewable energy technology. C. Whether and the extent to which the proposed amendment is inconsistent with the existing and proposed land uses; Landscaping and setback standards remain in effect for Electric Substations and Solar Generation Stations. D. Whether there have been changed conditions that require an amendment; The County’s regulation of Electric Substations and Solar Generation Stations through the LDC has generally responded to statutory changes. Regulations pertaining to Electric Substations were adopted in 2012 and have not been amended since then. Regulations pertaining to Solar Generation Stations were adopted in 2010 and were amended twice after that, as noted below. In 2022, the County adopted an ordinance to reflect state legislation that allowed solar facilities as permitted uses in all agricultural land use categories in a local government comprehensive plan, complying with setback and landscape buffer area criteria for similar uses in agricultural zoning districts. In 2023 the County adopted another ordinance exempting parcels on which Solar Generation Stations are located from meeting minimum frontage standards, which allowed the use of isolated properties that had access to, but less of a presence on roads. The ordinance also exempted the subdivision or redivision of platted or unplatted land - for solar generation facilities - from the plat or replat requirements. As population increases, so does the need for a reliable clean energy grid. The text amendment looks to reduce requirements for new solar generation facilities located within Agricultural Zoning Districts, which could hinder the expansion of reliable, clean energy infrastructure. The current round of changes proposed by FP&L are statutory and non-statutory in nature. Proposed text amendment #1 revises definitions to better match up with statutory definitions. Text amendment #2 incorporates screening and buffering standards set by state statute. Proposed text amendment #3, not statute-related, seeks to exclude security fencing and walls from the square footage calculations of Essential Utility Service Facilities structures. Proposed text amendment #4, not statute-related, is a minor verbiage change. Proposed text amendment #5 is also not statute-related and seeks to allow graphic depiction by qualified environmental professionals of Class (Category) III wetlands without updating survey legal descriptions. Staff supports the proposed changes with the minor change of statutes regulating, not exempting, Electric Substations. E. Whether and the extent to which the proposed amendment would result in demands on public facilities, and whether or to the extent to which the proposed amendment would exceed the capacity of such public facilities, including but not limited to transportation facilities, sewage facilities, water supply, parks, drainage, schools, solid waste, mass transit, and emergency medical facilities; The proposed amendments would not change concurrency-related review of future Electric Substations Page 28 of 428 Project Name: Electric Substation and Solar Generation Station LDC Text Amendment File No.: TLDC-2401-000033 13 and Solar Generation Plants. F. Whether and the extent to which the proposed amendment would result in significant adverse impacts on the natural environment; FP&L provides environmental impact reports for all plant sites, solar and electric, and mitigates for impacts. Research indicates that there is the potential for solar farms to raise daytime temperatures and even affect weather, but that is only for large scale farms. A solar farm would have to be greater than 750,000 square miles to present heat island effects and create its own weather systems. This compares with the typical FP&L St. Lucie County solar farm size of under one square mile. One potential negative impact of solar farms is the clearing and use of large areas of land for solar power facilities and the resulting adverse effect on native vegetation and wildlife through the loss of habitat and interference with rainfall and drainage. However, this is not occurring with FP&L solar farms, which are located on former citrus groves mostly devoid of native vegetation and habitat. The use of lands for solar farms precludes the reclaiming and reforestation of denuded sites, but such replanting is unlikely to occur in agricultural areas due to the inability to utilize land development to recoup the high costs of replanting lands. Many former groves are being repurposed as cattle farms, a use which has its own negative environmental impacts. G. Whether and the extent to which the proposed amendment would adversely affect the property values in the area; The amendments would not change any factors that would impact property values. State and County screening and buffering standards for Solar Generation Plants would remain in effect. Similarly as noted in the 2023 evaluation of then-proposed revisions, “the proposed amendment is not anticipated to have an adverse impact on property values in the area. Solar Generation Stations have a de minimus impact on agricultural uses permitted within these zoning districts. A review of the market values assigned by the St. Lucie County Property Appraiser to a small number of parcels with agricultural zoning indicates that the value of land developed as a Solar Generation Station may be modestly higher than the value of land used for agricultural purposes, which has not correlated to adverse impact on property values in the surrounding area.” H. Whether and the extent to which the proposed amendment would result in an orderly and logical development pattern specifically identifying any negative effects of such patterns; Not applicable. Solar Stations are permitted use in the County's AG Zoning Districts, with most - if not all - located in the AG-5 District.. I. Whether the proposed amendment would be in conflict with the public interest, and is in harmony with the purpose and intent of this code; The proposed amendments would not conflict with the public interest. J. Any other matters that may be deemed appropriate by the Planning and Zoning Commission or the Board of County Commissioners, in review and consideration of the proposed amendment. The Planning and Zoning Commission and the Board of County Commissioners may raise other matters regarding the proposed Land Development Code Text Amendment. STAFF RECOMMENDATION: Staff finds this petition to meet the Standards of Review as set forth in Section 11.06.03 of the St. Lucie County Land Development Code, and is not in conflict with the goals, objectives, and policies of the St. Lucie County Comprehensive Plan. Staff recommends the Planning and Zoning Commission forward this petition to the Page 29 of 428 Project Name: Electric Substation and Solar Generation Station LDC Text Amendment File No.: TLDC-2401-000033 14 Board of County Commissioners with a recommendation of approval, with a single revision noted below. LDC Section 3.01.01.D.2.a.: Essential Utility Service Facilities parcels shall be exempt from the lot width, lot size and road frontage requirements but all improvements on a parcel or parcels shall meet the maximum height requirements and all buildings and structures shall also meet the setback requirements of the zoning district in which they are located, unless otherwise exempted regulated under Section 163.3208, Florida Statutes. The improvements shall comply with all resource protection and development standards for vegetation protection, protection of environmentally sensitive lands, protection of habitat for endangered and threatened species, flood damage prevention and stormwater management. In addition, above ground mechanical improvements located outside the right-of-way and adjacent to residentially zoned property and road rights-of-way shall be screened by landscaping with the type and location of the improvement and landscape treatments to be determined at the time of permitting. Page 30 of 428 Underline is for additions. Strikethrough is for deletion. ORDINANCE NO. 2024-XX File No. TLDC-2401-000033 AN ORDINANCE OF THE BOARD OF COUNTY COMMISSIONERS OF ST. LUCIE COUNTY, FLORIDA, AMENDING LAND DEVELOPMENT CODE SECTION 2.00.00 (DEFINITIONS) TO AMEND SEC. 2.00.00 (DEFINITIONS) TO REVISE THE ESSENTIAL UTILITY SERVICE FACILITIES AND SOLAR GENERATION STATION DEFINITIONS AND ADD A NEW DEFINITION FOR ELECTRIC SUBSTATION; AMEND SECTION 3.01.01.D. (ZONING DISTRICTS, GENERALLY, PUBLIC SERVICES AND FACILITIES) TO HARMONIZE WITH STATUTORY LANGUAGE [F.S. 163.3208.(4)] THAT REGULATES SETBACKS AND LANDSCAPE BUFFERS FOR ELECTRIC SUBSTATIONS; AMEND SECTION 3.01.01.D. (ZONING DISTRICTS, PUBLIC SERVICES AND FACILITIES): TO NOT INCLUDE SCREENING WALLS AND FENCING IN THE CALCULATION OF SQUARE FOOTAGE FOR AN ESSENTIAL UTILITY SERVICE FACILITIES BUILDING OR STRUCTURE; AMEND SECTION 3.01.01.D. (ZONING DISTRICTS, PUBLIC SERVICES AND FACILITIES), REMOVING THE WORD “DISTRIBUTION” FROM “DISTRIBUTION SUBSTATIONS”; AMEND SECTION 7.10.28. (SUPPLEMENTAL STANDARDS, SOLAR GENERATION STATION) TO ADD THE NORTH ST. LUCIE RIVER WATER CONTROL DISTRICT AND FT. PIERCE FARMS WATER CONTROL DISTRICT CANALS OR RIGHTS OF WAY AS OWNERS OF CANALS ADJACENT TO NEW SOLAR GENERATION STATIONS WHICH DO NOT ACTIVATE THE PERIMETER BUFFER REQUIREMENT FOR THE SOLAR PROPERTY; AMEND SECTION 7.10.28. (SUPPLEMENTAL STANDARDS, SOLAR GENERATION STATION) TO EXEMPT NEW SOLAR GENERATION STATION APPLICATIONS FROM INCLUDING WRITTEN LEGAL DESCRIPTIONS OF CLASS (CATEGORY) III WETLANDS; PROVIDING FOR FINDINGS; PROVIDING FOR CONFLICTING PROVISIONS; PROVIDING FOR SEVERABILITY; PROVIDING FOR APPLICABILITY; PROVIDING FOR AN EFFECTIVE DATE; AND PROVIDING FOR ADOPTION. WHEREAS, the Board of County Commissioners of St. Lucie County, Florida, based on the testimony and evidence, including not limited to the staff report, has made the following determinations: 1.On August 1, 1990, the Board of County Commissioners of St. Lucie County,Florida, adopted the St. Lucie County Land Development Code. 2.This Board is authorized by Section 125.01(1)(h), Florida Statutes, to establish, coordinateand enforce zoning and such business regulations as are necessary for the protection ofthe public; and, 3.This Board is authorized by Section 125.01(1)(t), Florida Statutes, to adopt ordinances andresolutions necessary for the exercise of its powers and to prescribe fines and penaltiesfor the violations of ordinances in accordance with law. 4.Regulations pertaining to Electric Substations were adopted in 2012 and have not beenamended since then. Regulations pertaining to Solar Generation Stations were adoptedin 2010 and were amended twice after that. In 2022, the County adopted an ordinance toreflect state legislation that allowed solar facilities as permitted uses in all agricultural landuse categories in a local government comprehensive plan, complying with setback andlandscape buffer area criteria for similar uses in agricultural zoning districts. In 2023, theCounty adopted another ordinance exempting parcels on which Solar Generation Stations Page 31 of 428 Ordinance No. 2023-XX Electric Substation and Solar Generation Station Land Development Code Text Amendment File No.: . TLDC-2401-000033 Page 2 Underline is for additions. Strikethrough is for deletion. are located from meeting minimum frontage standards, which allowed the use of isolated properties that had access to, but less of a presence on roads. The ordinance also exempted the subdivision or redivision of platted or unplatted land from the requirement that a subdivision plat or replat be filed and approved. 4.On July 18, 2024, the Planning and Zoning Commission acting as the Local Planning Agency held a public hearing on the proposed ordinance after publishing due notice in theSt. Lucie News Tribune and recommended that the proposed Ordinance be forwardedwith a recommendation for approval/denial. 5.On __________, 2024, this Board held the first public hearing on the proposed ordinance,after publishing due notice in the St. Lucie News Tribune. 6.On __________, 2024, this Board held its second public hearing on the proposedordinance, after publishing due notice in the St. Lucie News Tribune. 7.The proposed amendments to the St. Lucie County Land Development Code areconsistent with the general purpose, goals, objectives, and standards of the St. LucieCounty Comprehensive Plan, are internally consistent with the remainder of the LandDevelopment Code and are in the best interest of the health, safety and public welfare of the citizens of St. Lucie County, Florida. NOW, THEREFORE, BE IT ORDAINED by the Board of County Commissioners of St. Lucie County, Florida that the St. Lucie County Land Development is amended as set forth in the following amendments, as shown in strikethrough and underline format in Section 2. SECTION 1. RATIFICATION OF RECITALS. The foregoing recitals are hereby ratified and confirmed as true and correct and are hereby made a part of this Ordinance. SECTION 2. This Ordinance specifically amends the St. Lucie County Land Development Code, as follows: : CHAPTER II – DEFINITIONS CHAPTER II - DEFINITIONS Section 2.00.00. - DEFINITIONS ** ** * Electric Substation: An electric substation is a use, including accessory administration or maintenance buildings and related accessory uses and structures, which takes electricity from the transmission grid and converts it to another voltage or a lower voltage so it can be distributed to customers through one or more lines. Words in strike through type are deletions from existing text. Words in underlined type are additions to existing text. Asterisks (***) indicate existing text not shown. Page 32 of 428 Ordinance No. 2023-XX Electric Substation and Solar Generation Station Land Development Code Text Amendment File No.: . TLDC-2401-000033 Page 3 Underline is for additions. Strikethrough is for deletion. Essential Utility Service Facilities: Small scale infrastructure improvements located outside transportation and utility rights-of-way that support the provision of public facilities and services and are required to be located in or near the neighborhood where the service is provided, including improvements that support the transmission or distribution systems of water, sanitary or storm sewage, cable, gas, electricity, and public safety, including poles, wires, mains, hydrants, drains, sewer lift stations, electric substations, pipes, conduits, police or fire call boxes, warning sirens, bus stops, stormwater retention or detention facilities, chloramine injection station, potable water booster station and other similar equipment necessary for the furnishing of adequate public service. Solar Generation Station: An energy generation facility comprised of one (1) or more freestanding, ground mounted photovoltaic modules or devices that capture solar energy, converts it to electrical energy, stores energy, or delivers energy to a transmission system for use in locations other than where it is generated. Solar generation stations typically utilize photovoltaic solar cells, but can also be combinations of light reflectors, concentrators, energy storage equipment, and heat exchangers. A Solar Generation Station is also known as a solar facility, solar plant, solar generation plant, solar farm, solar power plant, battery storage plant, energy storage plant or solar thermal power plant. Ground mounted solar devices that capture solar energy (panels) shall not count towards maximum lot coverage. A Solar Generation Station may include, as an accessory use to the operation of the Station, administrative and maintenance support facilities. * * * * * CHAPTER III – ZONING DISTRICTS Section 3.01.01.D. Generally - A.-C.: No changes. D.Public Services and Facilities. The intent of this Section is to address infrastructureimprovements that provide essential or important public services that by theirnature may be required throughout unincorporated St. Lucie County.1.Transportation and Utility Rights-of-Way. 1.Transportation and utility rights-of-way, except for those utility rights-of-waysubject to review and approval under F.S. Ch. 403, Part II, and the linearportion of transportation facilities, e.g., pipes, poles lines, wires, cables,conduits, pavement rails, drainage and other similar equipment andaccessories in connection herewith, shall be permitted in all zoning districtsand shall comply, as applicable, with the resource protection anddevelopment standards for vegetation protection, protection ofenvironmentally sensitive lands, protection of habitat for endangered andthreatened species, flood damage prevention and stormwater management. Prior to any local certification of consistency for those utility rights-of-waysubject to review and approval under F.S. Ch. 403, Part II, a conditional Page 33 of 428 Ordinance No. 2023-XX Electric Substation and Solar Generation Station Land Development Code Text Amendment File No.: . TLDC-2401-000033 Page 4 Underline is for additions. Strikethrough is for deletion. use review, in accordance with the provisions of Section 11.07.03, shall be required. 2.Essential Utility Service Facilities. Essential Utility Service Facilities that support the operation and function of a utility service provider shall be permitted in all zoning districts, subject to compliance with the provisions of this Section. For purposes of this Section, the term "service provider" shall mean a public entity; a Florida Public Service Commission certificated utility entity, a non-regulated utility entity such as a cable television service provider, or a public or a quasi-public entity, such as a community development district or drainage district. a.Essential Utility Service Facilities parcels shall be exempt from the lot width, lot size and road frontage requirements but all improvements on a parcel or parcels shall meet the maximum height requirements and all buildings and structures shall also meet the setback requirements of the zoning district in which they are located, unless otherwise regulated under Section 163.3208, Florida Statutes. The improvements shall comply with all resource protection and development standards for vegetation protection, protection of environmentally sensitive lands, protection of habitat for endangered and threatened species, flood damage prevention and stormwater management. In addition, above ground mechanical improvements located outside the right- of-way and adjacent to residentially zoned property and road rights-of-way shall be screened by landscaping with the type and location of the improvement and landscape treatments to be determined at the time of permitting. b.Except as provided for under the provisions of paragraph a above, Essential Utility Service Facilities involving buildings or structures that shield the infrastructure for aesthetic purposes or that provide storage incidental to the Essential Utility Service shall be permitted upon a demonstration of compliance with all applicable sections of this Code, and the provisions below: 1)The cumulative area of the Essential Utility Service Facilities building or structure shall not exceed 300 square feet. Essential Utility Service Facilities involving buildings or structures with a cumulative total area larger than 300 square feet, or not compliant with this Section, shall only be permitted within a zoning district when specifically listed as a permitted, conditional or accessory use. Page 34 of 428 Ordinance No. 2023-XX Electric Substation and Solar Generation Station Land Development Code Text Amendment File No.: . TLDC-2401-000033 Page 5 Underline is for additions. Strikethrough is for deletion. 2)The Essential Utility Service Facilities building orstructure shall comply with all applicable buildingcodes, resource protection and development design standards, including landscaping and screeningrequirements. Where necessary, the Planning andDevelopment Services Director may approve alternative plans for security purposes or to ensurecompatibility with the surrounding zoning district andexisting uses. 3)Within residentially zoned areas, Essential UtilityService Facilities buildings or structures shall requireapproval by the Planning and Development ServicesDirector. The Director shall deny any building orstructure that would likely create an adverse impacton neighboring properties. 4)For the purpose of this section, an opaque screeningwall or fence, erected or constructed for the purposeof screening or providing security to an Essential Utility Service Facility shall not be included in the 300square foot limitation cited in Paragraph 1 above. Allscreening walls or fences shall be subject to applicable local height and site distance placementrequirements. c.Essential Utility Service Facilities, as defined in this Code,existing as of May 1, 2012 shall be considered permitteduses in the zoning district in which they are located andallowed to continue in compliance with this Code and anyapplicable conditions of approval. 3.Public services and facilities not meeting the provisions forTransportation and Utility Rights-of-way or Essential Utility ServiceFacilities, including but not limited to those involving distributionsubstations, generation plants, treatment plants, or stormwaterpumping stations shall be permitted within zoning districts onlywhen listed as a permitted or conditional use. Where an EssentialUtility Service Facilities improvement is specifically addressed inanother section of this Code, and conflicts with this Section, the most restrictive requirements shall apply. In the event any of the provisions of this Section prohibit the installation of an emergency improvement or a utility improvement required by an environmental regulatory agency, the Planning and Development Services Director may grant a waiver of the provisions of this Section upon determination that strict application would result in a threat to public health, safety or welfare. Page 35 of 428 Ordinance No. 2023-XX Electric Substation and Solar Generation Station Land Development Code Text Amendment File No.: . TLDC-2401-000033 Page 6 Underline is for additions. Strikethrough is for deletion. * * * * * CHAPTER VII – DEVELOPMENT DESIGN AND IMPROVEMENT STANDARDS Section 7.10.28. Supplemental Standards, Solar Generation Station 7.10.28. Solar Energy. The following provisions are intended to facilitate the commercial generation and distribution of solar power and the use of on-site solar energy systems to meet the energy demands of buildings and support facilities in the unincorporated County. All Solar equipment and devices shall comply with Florida Statutes and shall be certificated by the Florida Solar Energy Commission. A.Solar Generation Station. In addition to other applicable sections of this Code, a SolarGeneration Station shall be subject to the following provisions: 1.Solar Generation Stations are permitted uses in the AG 1, AG 2. 5 and AG 5 Zoning Districts and shall require submittal of a Minor Site Plan application. Solar Generation Stations not located within an Agricultural Zoning District shall require submittal of a Major Site Plan application concurrent with a Conditional Use Permit, when required. a)In Zoning Districts in which a Major Site Plan application is required, the development shall be subject to the following supplemental criteria: 1. Physical access to a Solar Generation Station shall be restricted by fencing or walls. Razor wire is prohibited. All fencing and wall details shall be provided for review and approval as part of the required site plan. 2. The devices that capture energy and convert it to electricity shall not be placed in wetlands, environmentally sensitive resources or habitats, imperiled and critically imperiled habitats as defined by the Florida Natural Areas Inventory, and/or buffers. Any environmental impacts from such devices, or any component of a Solar Generation Station, shall only be allowed in compliance with the provisions of the County's Comprehensive Plan and Land Development Code. 3.All devices that capture and convert energy to electricity shall be located at least fifty (50) feet from any lot line under separate ownership, unless otherwise approved by the Board of County Commissioners.4. All Solar Generation Station sites must comply with the landscaping and screening requirements of the Land Development Code. The perimeter buffer landscaping requirements may be waived by the Board of County Commissioners, if it is shown to the satisfaction of the Page 36 of 428 Ordinance No. 2023-XX Electric Substation and Solar Generation Station Land Development Code Text Amendment File No.: . TLDC-2401-000033 Page 7 Commission that the adjoining property owners have no objection to the landscaping waiver. Interior vehicular use area landscaping requirements may be waived by the Commission, to the extent necessary to ensure optimal solar access. The Board of County Commissioners may require additional landscaping to enhance compatibility with adjacent land uses. 5.On-site power lines shall be placed underground to the maximum extent possible. 8. Surveys for Solar Generation Stations shall be compliant with the requirements of Section 11.02.09(A)(2)(d), except that any Category III wetlands, as defined by the St Lucie County Comprehensive Plan, that are located on the site need only be graphically located on the project site plan, provided that they have been identified with field flagging or by GPS (or equivalent) coordinate mapping, by a qualified Professional Wetland Scientist (PWS). All such wetlands are to be buffered in accord with the County’s Comprehensive Plan, unless otherwise proposed for alteration or impact. Wetlands mapped under this paragraph are not required to provide individual conservation easements or a Preserve Area Monitoring and Management Plan (PAMMP) for the project site, provided that all required buffers are indicated on the project site plan and appropriate management restrictions and obligations are set out in any site plan approval orders or resolutions, for the Minor Site Plan activity. 6. The paving requirements within Section 7.05.07(B) shall not apply to Solar Generation Station that utilize unpaved public or private roads and roadways for access. 7. The minimum frontage requirement for a Solar Generation Station in the AG-5, AG-2.5 or AG-1 Zoning District is zero (0) feet, provided legal and sufficient ingress and egress to the facility is demonstrated to the satisfaction of the County Attorney, the County Engineer and the Planning and Development Services Director. Where such access to a Solar Generation Station site relies upon an easement, easements, or any interest in land that is less than fee simple ownership, the Final Development Order granting Minor Site Plan approval and the Site Plan shall identify the Book and Page where such easement or other right of access is recorded in the Official Records of St. Lucie County. The Development Order and the Site Plan shall contain the following statement: "NEITHER ST. LUCIE COUNTY NOR ANY OTHER GOVERNMENTAL OR PUBLIC AGENCY IS RESPONSIBLE FOR THE MAINTENANCE, UPKEEP OR IMPROVEMENT OF ANY PRIVATE DRIVES, ROADS, STREETS, EASEMENTS, OR RIGHTS-OF-WAY PROVIDING INGRESS AND EGRESS OR DRAINAGE SERVICE TO THE PROPERTY THAT IS THE SUBJECT OF THIS DEVELOPMENT ORDER." Page 37 of 428 SECTION 3. CONFLICTING PROVISIONS. Special acts of the Florida Legislature applicable only to unincorporated areas of St. Lucie County, County Ordinances and County Resolutions, or parts thereof, in conflict with this Ordinance are hereby superseded by this Ordinance to the extent of such conflict. SECTION 4. SEVERABILITY. If any portion of this Ordinance is for any reason held or declared to be unconstitutional, inoperative, or void, such holding shall not affect the remaining portions of this Ordinance. If this Ordinance or any provision thereof shall be held to be inapplicable to any person, property, or circumstance, such holding shall not affect its applicability to any other person, property, or circumstance. SECTION 5. APPLICABILITY OF ORDINANCE. This Ordinance shall be applicable in the unincorporated area of St. Lucie County. SECTION 6. FILING WITH THE DEPARTMENT OF STATE. The Clerk is hereby directed forthwith to send a certified copy of this Ordinance to the Bureau of Administrative Code and Laws, Department of State, The Capitol, Tallahassee, Florida 32304. SECTION 7. EFFECTIVE DATE. This Ordinance shall take effect upon filing with the Department of State. Underline is for additions. Strikethrough is for deletion. Page 38 of 428 Ordinance No. 2023-XX Electric Substation and Solar Generation Station Land Development Code Text Amendment File No.: . TLDC-2401-000033 Page 8 Underline is for additions. Strikethrough is for deletion. SECTION 8. CODIFICATION. Provisions of this ordinance shall be incorporated in the St. Lucie County Land Development Code, and the word “ordinance” may be changed to “section”, “article”, or other appropriate word, and the sections of this ordinance may be renumbered or re-lettered to accomplish such intention. SECTION 9. ADOPTION. After motion and second, the vote on this ordinance was as follows: Cathy Townsend, Chair X Chris Dzadovsky, Vice-Chair X Linda Bartz, Commissioners X Larry Leet, Commissioner X Jamie Fowler, Commissioner X PASSED AND DULY ENACTED this ___ day of __________, 2024. Attest: Board of County Commissioners St. Lucie County, Florida By: Deputy Clerk Chair Approved As To Form and Correctness: By: County Attorney Page 39 of 428 underline for addition strike through for deletion Page 1 of 7 May 10, 2025 CHAPTER II DEFINITIONS 2.00.00. DEFINITIONS Essential Utility Service Facilities: Small scale infrastructure improvements located outside transportation and utility rights-of-way that support the provision of public facilities and services and are required to be located in or near the neighborhood where the service is provided, including improvements that support the transmission or distribution systems of water, sanitary or storm sewage, cable, gas, electricity, and public safety, including poles, wires, mains, hydrants, drains, sewer lift stations, electrical substations, pipes, conduits, police or fire call boxes, warning sirens, bus stops, stormwater retention or detention facilities, chloramine injection station, potable water booster station and other similar equipment necessary for the furnishing of adequate public service Electric Substation: An electric substation is a use, including accessory administration or maintenance buildings and related accessory uses and structures, which takes electricity from the transmission grid and converts it to another voltage or a lower voltage so it can be distributed to customers through one or more lines. Solar Generation Station: An energy generation facility comprised of one (1) or more freestanding, ground mounted photovoltaic modules or devices that capture solar energy, converts it to electrical energy, stores energy, or delivers energy to a transmission system for use in locations other than where it is generated. Solar generation stations typically utilize photovoltaic solar cells, but can also be combinations of light reflectors, concentrators, energy storage equipment, and heat exchangers. A Solar Generation Station is also known as a solar facility, solar plant, solar generation plant, solar farm, solar power plant, battery storage plant, energy storage plant or solar thermal power plant. Ground mounted solar devices that capture solar energy (panels) shall not count towards maximum lot coverage. A Solar Generation Station may include, as an accessory use to the operation of the Station, administrative and maintenance support facilities. ********************** CHAPTER III ZONING DISTRICTS 3.00.00. - ZONING DISTRICTS 3.01.01. - Generally. A. Permitted Uses. No structure or land in the unincorporated area of St. Lucie County shall hereafter be constructed, built, moved, remodeled, reconstructed, used, or occupied except in accordance with the requirements of the zoning district in which the structure or land is located, unless it is a Page 40 of 428 underline for addition strike through for deletion Page 2 of 7 May 10, 2025 nonconformity under the provisions of Section 10.00.02 of this Code. B. Conditional Uses. No structure or land shall be constructed, built, remodeled, reconstructed, used, or occupied as a conditional use under this Code except as approved under the procedures and requirements of Section 11.07.00, and the standards of Section 11.07.03. C. Accessory Uses and Structures. Accessory structures and uses are permitted in any zoning district in connection with any principal lawfully existing permitted use within such district, or in connection with any existing conditional use within such district, subject to the requirements of Section 11.07.00, provided that all accessory structures or uses shall meet the requirements for the zoning district in which the structure or use is located, as provided in Section 3.01.01, and all other requirements of this Section. D. Public Services and Facilities. The intent of this Section is to address infrastructure improvements that provide essential or important public services that by their nature may be required throughout unincorporated St. Lucie County. 1. Transportation and Utility Rights-of-Way. Transportation and utility rights-of-way, except for those utility rights-of-way subject to review and approval under F.S. Ch. 403, Part II, and the linear portion of transportation facilities, e.g., pipes, poles lines, wires, cables, conduits, pavement rails, drainage and other similar equipment and accessories in connection herewith, shall be permitted in all zoning districts and shall comply, as applicable, with the resource protection and development standards for vegetation protection, protection of environmentally sensitive lands, protection of habitat for endangered and threatened species, flood damage prevention and stormwater management. Prior to any local certification of consistency for those utility rights-of-way subject to review and approval under F.S. Ch. 403, Part II, a conditional use review, in accordance with the provisions of Section 11.07.03, shall be required. 2. Essential Utility Service Facilities. Essential Utility Service Facilities that support the operation and function of a utility service provider shall be permitted in all zoning districts, subject to compliance with the provisions of this Section. For purposes of this Section, the term "service provider" shall mean a public entity; a Florida Public Service Commission certificated utility entity, a non-regulated utility entity such as a cable television service provider, or a public or a quasi-public entity, such as a community development district or drainage district. a. Essential Utility Service Facilities parcels shall be exempt from the lot width, lot size and road frontage requirements but all improvements on a parcel or parcels shall meet the maximum height requirements and all buildings and structures shall also meet the setback requirements of the zoning district in which they are located, unless otherwise exempted under Section 163.3208, Florida Statutes. The improvements shall comply with all resource protection and development standards for vegetation protection, protection of environmentally sensitive lands, protection of habitat for endangered and threatened species, flood damage prevention and stormwater management. In addition, above ground mechanical improvements located outside the right-of-way and adjacent to residentially zoned property and road rights-of-way shall be screened by landscaping with the type and location of the improvement and landscape treatments to be determined at the time of permitting. Page 41 of 428 underline for addition strike through for deletion Page 3 of 7 May 10, 2025 b. Except as provided for under the provisions of paragraph a above, Essential Utility Service Facilities involving buildings or structures that shield the infrastructure for aesthetic purposes or that provide storage incidental to the Essential Utility Service shall be permitted upon a demonstration of compliance with all applicable sections of this Code, and the provisions below: 1) The cumulative area of the Essential Utility Service Facilities building or structure shall not exceed 300 square feet. Essential Utility Service Facilities involving buildings or structures with a cumulative total area larger than 300 square feet, or not compliant with this Section, shall only be permitted within a zoning district when specifically listed as a permitted, conditional or accessory use. 2) The Essential Utility Service Facilities building or structure shall comply with all applicable building codes, resource protection and development design standards, including landscaping and screening requirements. Where necessary, the Planning and Development Services Director may approve alternative plans for security purposes or to ensure compatibility with the surrounding zoning district and existing uses. 3) Within residentially zoned areas, Essential Utility Service Facilities buildings or structures shall require approval by the Planning and Development Services Director. The Director shall deny any building or structure that would likely create an adverse impact on neighboring properties. 4) For the purpose of this section, an opaque screening wall or fence, erected or constructed for the purpose of screening or providing security to an Essential Utility Service Facility shall not be included in the 300 square foot limitation cited in Paragraph 1 above. All screening walls or fences shall be subject to applicable local height and site distance placement requirements. c. Essential Utility Service Facilities, as defined in this Code, existing as of May 1, 2012 shall be considered permitted uses in the zoning district in which they are located and allowed to continue in compliance with this Code and any applicable conditions of approval. 3. Public services and facilities not meeting the provisions for of Transportation and Utility Rights-of- way or Essential Utility Service Facilities, including but not limited to those involving distribution substations, generation plants, treatment plants, or stormwater pumping stations shall be permitted within zoning districts only when listed as a permitted or conditional use. Where an Essential Utility Service Facilities improvement is specifically addressed in another section of this Code, and conflicts with this Section, the most restrictive requirements shall apply. In the event any of the provisions of this Section prohibit the installation of an emergency improvement or a utility improvement required by an environmental regulatory agency, the Planning and Development Services Director may grant a waiver of the provisions of this Section upon determination that strict application would result in a threat to public health, safety or welfare. ********************** Page 42 of 428 underline for addition strike through for deletion Page 4 of 7 May 10, 2025 CHAPTER VII DEVELOPMENT DESIGN AND IMPROVEMENT STANDARDS 7.10.00. - SUPPLEMENTAL STANDARDS 7.10.28. Solar Energy. The following provisions are intended to facilitate the commercial generation and distribution of solar power and the use of on-site solar energy systems to meet the energy demands of buildings and support facilities in the unincorporated County. All Solar equipment and devices shall comply with Florida Statutes and shall be certificated by the Florida Solar Energy Commission. A. Solar Generation Station. In addition to other applicable sections of this Code, a Solar Generation Station shall be subject to the following provisions: 1. Solar Generation Stations are permitted uses in the AG 1, AG 2. 5 and AG 5 Zoning Districts and shall require submittal of a Minor Site Plan application. Solar Generation Stations not located within an Agricultural Zoning District shall require submittal of a Major Site Plan application concurrent with a Conditional Use Permit, when required. a) In Zoning Districts in which a Major Site Plan application is required, the development shall be subject to the following supplemental criteria: 1. Physical access to a Solar Generation Station shall be restricted by fencing or walls. Razor wire is prohibited. All fencing and wall details shall be provided for review and approval as part of the required site plan. 2. The devices that capture energy and convert it to electricity shall not be placed in wetlands, environmentally sensitive resources or habitats, imperiled and critically imperiled habitats as defined by the Florida Natural Areas Inventory, and/or buffers. Any environmental impacts from such devices, or any component of a Solar Generation Station, shall only be allowed in compliance with the provisions of the County's Comprehensive Plan and Land Development Code. 3. All devices that capture and convert energy to electricity shall be located at least fifty (50) feet from any lot line under separate ownership, unless otherwise approved by the Board of County Commissioners. 4. All Solar Generation Station sites must comply with the landscaping and screening requirements of the Land Development Code. The perimeter buffer landscaping requirements may be waived by the Board of County Commissioners, if it is shown to the satisfaction of the Commission that the adjoining property owners have no objection to the landscaping waiver. Interior vehicular use area landscaping requirements may be waived by the Commission, to the extent necessary to ensure optimal solar access. The Board of County Commissioners may require additional landscaping to enhance compatibility with adjacent land uses. 5. On-site power lines shall be placed underground to the maximum extent possible. 6. Surveys for Solar Generation Stations shall be compliant with the requirements of Section 11.02.09(A)(2)(d), except that any Category III wetlands, as defined by the St Lucie County Page 43 of 428 underline for addition strike through for deletion Page 5 of 7 May 10, 2025 Comprehensive Plan, that are located on the site need only be graphically located on the project site plan, provided that they have been identified with field flagging or by GPS (or equivalent) coordinate mapping, by a qualified Professional Wetland Scientist (PWS). All such wetlands are to be buffered in accord with the County’s Comprehensive Plan, unless otherwise proposed for alteration or impact. b) In Zoning Districts in which a Minor Site Plan application is required the development shall be subject to the following supplemental criteria: 1. Physical access to a Solar Generation Station may be restricted by fencing or walls. Razor wire is prohibited. All fencing and wall details shall be provided for review and approval as part of the required site plan. 2. The devices that capture energy and convert it to electricity shall not be placed in wetlands, environmentally sensitive resources or habitats, imperiled and critically imperiled habitats as defined by the Florida Natural Areas Inventory, and/or buffers: Any environmental impacts from such devices, or any component of a Solar Generation Station, shall only be allowed in compliance with the provisions of the County's Comprehensive Plan and Land Development Code. 3. All devices that capture and convert energy to electricity shall comply with the setback regulations of the underlying Agricultural Zoning District, or provide a 25-foot setback from all perimeter lot or parcel lines, whichever is less. 4. Perimeter buffers and landscaping requirements are only required for property lines that are directly adjacent to established residential uses and which are not separated by a public right-of-way, South Florida Water Management District Canal, North St. Lucie River Water Control District, or Ft. Pierce Farms Water Control District Canals or Rights of Way. When a Solar Generation Station is adjacent to a non-agricultural zoning district the buffer and landscape requirements for the underlying agricultural zoning district shall apply. The perimeter buffer landscaping requirements may be waived by the Board of County Commissioners, if it is shown to the satisfaction of the Commission that the adjoining property owners from the nonagricultural zoning district property have no objection to the landscaping requirement being waived. 5. On-site power lines shall be placed underground to the maximum extent possible. 6. The paving requirements within Section 7.05.07(B) shall not apply to Solar Generation Station that utilize unpaved public or private roads and roadways for access. 7. The minimum frontage requirement for a Solar Generation Station in the AG-5, AG-2.5 or AG-1 Zoning District is zero (0) feet, provided legal and sufficient ingress and egress to the facility is demonstrated to the satisfaction of the County Attorney, the County Engineer and the Planning and Development Services Director. Where such access to a Solar Generation Station site relies upon an easement, easements, or any interest in land that is less than fee simple ownership, the Final Development Order granting Minor Site Plan approval and the Site Plan shall identify the Book and Page where such easement or other right of access is recorded in the Official Records of St. Lucie County. The Development Order and the Site Plan shall contain the following statement: "NEITHER ST. LUCIE COUNTY NOR ANY OTHER GOVERNMENTAL OR PUBLIC AGENCY IS RESPONSIBLE FOR THE MAINTENANCE, UPKEEP OR IMPROVEMENT OF ANY PRIVATE DRIVES, ROADS, STREETS, EASEMENTS, OR RIGHTS-OF-WAY PROVIDING INGRESS AND EGRESS OR DRAINAGE SERVICE TO THE PROPERTY THAT IS THE SUBJECT OF THIS Page 44 of 428 underline for addition strike through for deletion Page 6 of 7 May 10, 2025 DEVELOPMENT ORDER." 8. Surveys for Solar Generation Stations shall be compliant with the requirements of Section 11.02.09(A)(2)(d), except that any Category III wetlands, as defined by the St Lucie County Comprehensive Plan, that are located on the site need only be graphically located on the project site plan, provided that they have been identified with field flagging or by GPS (or equivalent) coordinate mapping, by a qualified Professional Wetland Scientist (PWS). All such wetlands are to be buffered in accord with the County’s Comprehensive Plan, unless otherwise proposed for alteration or impact. Wetlands mapped under this paragraph are not required to provide individual conservation easements or a Preserve Area Monitoring and Management Plan (PAMMP) for the project site, provided that all required buffers are indicated on the project site plan and appropriate management restrictions and obligations are set out in any site plan approval orders or resolutions, for the Minor Site Plan activity. B. Accessory and Other Non-Utility Solar Energy Systems. In addition to other applicable sections of this Code, accessory solar and other non-utility solar energy systems shall be subject to the following provisions: 1. All solar panels and devices are considered structures and subject to the requirements from the Land Development Code, together with all other applicable codes and ordinances, unless otherwise provided for in this Code. Solar panels installed on roofs are exempt from the building height requirements. Solar panels installed on rooftops shall be located at least three (3) feet from the roof edge. 2. Non-roof installed solar energy devices integrated into the architecture of the building, such as the walls of the building, shall be no greater than ten (10) feet above the maximum height requirements of the zoning district. 3. Ground or pole mounted systems shall be limited to a height of ten (10) feet above the base floor elevation of the primary structure. 4. Solar energy systems shall not be located in front or side corner yards of any parcel, unless the following are met: a) the conditions of the side and back yards prohibit the installation of a system, and b) the lot is one (1) acre or greater, and c) adequate buffering along the adjacent roadway is provided, and d) the location is approved by the Director of Planning and Development Services. 5. Solar ground and pole mounted systems less than six ( 6) feet in height may encroach into the side and rear setback area, but in no case shall the system be located closer than five ( 5) feet from the property line. Where the system is higher than six (6) feet in height the setback requirements of the zoning district shall apply. 6. Solar collectors may be co-located on communication towers, and parking lot and street light poles, in which case the height and setback requirements for said tower/pole shall apply. 7. All new exterior electrical lines and utility wires connecting a ground or pole mounted solar system to the building it serves shall be buried underground. 8. The Board of County Commissioners may allow for a modification of these accessory use provisions when the proposed solar energy system will serve buildings within a planned development project. The Page 45 of 428 underline for addition strike through for deletion Page 7 of 7 May 10, 2025 modification shall be identified on the site plan graphics and within the resolution granting approval to the planned development. 9. Waiver. In the event any of the provisions in this subsection have the effect of prohibiting or precluding the installation of a solar energy system, the applicant shall have the right to apply for a waiver from these provisions to the Director of Planning and Development Services or designee. The Director may grant a waiver upon determining that strict application of the Code would result in prohibiting the installation of a solar energy system. 10. Landscape Waiver. The Environmental Resources Director may waive the landscaping requirements of the Land Development Code to the extent necessary to ensure optimal solar access. 11. Any approval of a solar energy system does not create any actual or inferred solar energy system easement against adjacent property and/ or structures. The owner and/or property owner of a solar energy system shall not infer or claim any rights to protective writs to any caused shadows or operating ineffectiveness against future development adjacent to or higher than the property location of the solar energy system. The approval of any solar energy system granted by St. Lucie County shall not create any future liability or infer any vested rights to the owner and/ or property owner of the solar energy system on the part of the County for any future claims against said issuance of approval of the solar energy system that result from reliance on this section or any administrative decision lawfully made thereunder. Page 46 of 428 A LEGACY OF EXPERTISE AND EXCELLENCE 2980 SOUTH 25TH STREET | FT. PIERCE FL 34981 | (772)464-3537 | FAX (772 464-9497 File Number: 24-011 January 28, 2024 Mr. Kori Benton, AICP, Planning Manager St Lucie County Planning and Development Services Department 2300 Virginia Avenue Ft. Pierce, Florida 34982 Subject: Proposed Amendment to Section 7.10.28, St Lucie County Land Development Code. Dear Mr. Benton: Attached, please find our application for amendment to Sections 2.00.00 and 7.10.28 of the St. Lucie County Land Development Code. The proposed amendment to Section 2.00.00 is to the existing definition of a Solar Energy Facility. The proposed revision, the addition of the phrase ‘energy storage equipment,’ is from the base statutory descriptions for these type uses and activities found in Section 163.3205, Florida Statues. In addition, we have added one clarifying sentence to this County definition that addresses the ability to provide for accessory administrative and maintenance support facilities, consistent with, and as authorized under, this same statutory section. We are also proposing a clarification to the regulations governing the survey mapping submission requirements for those Solar Generation Stations located in the AG 1, AG 2. 5 and AG 5 Zoning Districts. Specifically, we are seeking to streamline the survey mapping needs for Class II and III wetlands that may be located on these sites, and to further streamline the processes for mapping of them if certain minimum criteria are met. There is also a small clarification to include the identification and treatment of the North St. Lucie River Water Control District and Ft. Pierce Farms Water Control District Canal Rights of Way in a manner consistent with how adjacent property issues are dealt with when these sites are located next to a South Florida Water Management District Canal. Thank you for your attention to this submission. As you look through this material, if you have any questions, or would like to discuss these matters further, please let me know. Sincerely Dennis J. Murphy Principal Planner Page 47 of 428 EnvironmEntal rEsourcEs Final rEport TO: Thad Crowe, Planning & Development Services THROUGH: Aimee L. Cooper, Environmental Regulations Manager Amy E. Griffin, Environmental Resources Director FROM: Brian Arbeiter, Senior Environmental Planner DATE: June 5th, 2024 SUBJECT: SLC LDC Text Amendment – Solar Supplemental Standard (7.10.28) TLDC-2401-000033 Background The Environmental Resources Department (ERD) is in receipt of the May 21st, 2024, date-stamped submittal transmitted on May 24th, 2024, with comments due June 10th, 2024, from Planning and Development Services. The applicant is seeking approval of a Land Development Code Text Amendment (TLDC) to LDC 2.00.00 & 7.10.28 to amend the definition of a Solar Energy Facility, to add the North St. Lucie River Water Control District and Ft. Pierce Farms Water Control District to the entities listed within the perimeter landscaping section, to clarify survey requirements for Category III wetlands, and to propose new standards for Category III wetland preserve areas in an effort to streamline the solar field development process. The proposal includes amendments to LDC 2.00.00 - Definitions and LDC 7.10.00 – Supplemental Standards. Findings The proposed Land Development Code Text Amendments were reviewed for consistency with the spirit and intent of the Comprehensive Plan while considering the unique characteristics of solar energy development. The following amendments were highlighted within the environmental review: LDC 7.10.28.A.1.b.4 is preexisting text that outlines the requirement of perimeter landscaping for property lines which lie adjacent to established residential uses and are not otherwise separated by a public right-of-way or a South Florida Water Management District canal. Amending this section to add two (2) more districts (Fort Pierce Farms Water Control District and North St. Lucie River Water Control District), as proposed within the text amendment, does not deviate from the original intention of requiring landscaping directly adjacent to established residential use. The amendment simply expands the list of canal districts to include all those found within St. Lucie County. LDC 7.10.28.A.1.a.6. is proposed text to streamline the surveying requirements for solar energy developments that require a Major Site Plan, and which are located on sites that contain Category III wetlands. LDC 11.02.09.A.2.d., which is applicable to most development applications, requires boundary surveys to depict “The limits and elevations of any jurisdictional wetlands, which shall contain bearing and distance information used in determining the extent of these areas, along with the identification of the agency or agencies claiming jurisdiction.” This amendment proposes to include the limits of the wetland on the site plan, instead of the boundary survey, and to utilize GPS (or equivalent) coordinate mapping. Additionally, this amendment specifies that a Professional Wetland Scientist (PWS) shall delineate the limits of the wetland, which is a more stringent qualification requirement than currently provided. This is a procedural amendment initiated by the applicant that does not pose a significant change to current procedure and will not result in adverse environmental impacts. The limits of the wetland shall still be depicted and verified by the appropriate state and Federal agencies through the Environmental Resource Permit (ERP) process. Any proposed impacts to the wetland and/or the wetland buffer shall still be required to be reviewed Page 48 of 428 via the wetland waiver process. This amendment does not apply to Category I and II wetlands, which shall continue to be depicted on the boundary survey in accordance with LDC 11.02.09.A.2.d. LDC 7.10.28.A.1.b.8 also includes proposed text to streamline the surveying requirements for solar energy developments that require a Minor Site Plan, and which are located on sites that contain Category III wetlands. The included language found within the first paragraph of this section reflects that which is proposed for LDC 7.10.28.A.1.a.6. The 2nd paragraph within this section proposes a change to the instrumentation utilized to cover and manage Category III Wetlands located within solar energy development sites that require a Minor Site Plan. Currently, all onsite wetlands (Category I, II, & III) proposed to be preserved are required to be covered by a conservation easement (CE) and managed by a Preserve Area Management and Monitoring Plan (PAMMP), which are recorded together. The applicant wishes to change the protection instrumentation from the utilization of a CE and PAMMP to a drafted set of restrictions and obligations similar to the CE and PAMMP presented as an exhibit within the site plan application package, which would be reviewed by staff through the site plan process, and then codified through the site plan development order. The applicant’s reasoning for this proposed change is multifaceted but relates to the viability of small low quality isolated man-made wetlands located along historic agriculture furrows and their relation to the viability of development or sale of the property in the far future. Ultimately, the Category III Wetlands will still be protected and preserved throughout the life of the solar energy development, but by the utilization of different instrumentation that mimics a time-restricted CE and PAMMP. A traditional CE and PAMMP shall still be required for Category I and II Wetlands for all development types, and for Category III Wetlands for solar energy developments that require a Major Site Plan. Recommendation ERD has no objection to the proposed Land Development Code Text Amendment. Please contact Brian Arbeiter at 772-462-2866 if you have any questions. Page 49 of 428 Page 50 of 428 TR-39758785 ST. LUCIE COUNTY PLANNING AND ZONING COMMISSION PUBLIC HEARING AGENDA July 18, 2024 NOTICE OF A PROPOSED AMENDMENT TO THE LAND DEVELOPMENT CODE The St. Lucie County Planning and Zoning Commission is scheduled to review and consider a recommendation on the following proposal for adoption by Ordinance: ORDINANCE AN ORDINANCE OF THE BOARD OF COUNTY COMMISSIONERS OF ST. LUCIE COUNTY, FLORIDA, AMENDING LAND DEVELOPMENT CODE SECTION 2.00.00 (DEFINITIONS) TO ADD A DEFINITION OF “ELECTRIC SUBSTATION,” AND TO REVISE THE DEFINITIONS OF “ESSENTIAL UTILITY SERVICE FACILITIES” AND “SOLAR GENERATION STATION”; AMEND SECTION 3.00.01.D. (ZONING DISTRICTS - GENERALLY, PUBLIC SERVICES AND FACILITIES) TO REVISE SETBACK, SCREENING, AND LANDSCAPING STANDARDS AND RE-PHRASE “DISTRIBUTION SUBSTATION”; AND AMEND SECTION 7.10.28 (SUPPLEMENTAL STANDARDS, SOLAR GENERATION STATION) TO ALLOW FOR GRAPHIC DEPICTION OF CATEGORY III WETLANDS WITHOUT REQUIRING WRITTEN LEGAL DESCRIPTIONS OF SUCH WETLANDS AND ADDING SPECIFICALLY NAMED CANAL OR WATER CONTROL DISTRICTS OWNING CANAL RIGHTS-OF-WAY THAT DO NOT REQUIRE PERIMETER LANDSCAPE BUFFERS FOR ADJACENT SOLAR GENERATION STATION PROPERTIES UNDER DEVELOPMENT; PROVIDING FOR FINDINGS; PROVIDING FOR CONFLICTING PROVISIONS; PROVIDING FOR SEVERABILITY; PROVIDING FOR APPLICABILITY; PROVIDING FOR AN EFFECTIVE DATE; AND PROVIDING FOR ADOPTION. Petition Applicant: Culpepper & Terpening, Inc, on behalf of Florida Power & Light. Petition File Number: TLDC-2401-000033. Purpose: The proposed amendments to the Land Development Code would revise and add definitions of solar generation-related facilities that reflect statutory language; reference statutory regulations regarding setbacks, screening, and buffering; remove fences or walls from the calculation of Solar Generation Station structure size; remove the word “Distribution” from “Distribution Substations”; allow the graphic-only depiction of Class III wetlands; and adding specifically named canal or water control districts owning canal rights-of-way that do not require perimeter landscape buffers within adjacent Solar Generation Station properties under development. The Planning and Zoning Commission’s PUBLIC HEARING to review the proposed Land Development Code Text Amendment will be held in the Commission Chambers, Roger Poitras Annex, 3rd Floor, St. Lucie County Administration Building, 2300 Virginia Avenue, Fort Pierce, Florida on Thursday, July 18, 2024, beginning at 6:00 pm or as soon thereafter as possible. All interested persons will be given an opportunity to be heard. Written comments received in advance of the public hearing will also be considered. Written comments to the Planning and Zoning Commission should be received by the Planning and Development Services Department - Planning Division at least 3 days prior to the scheduled hearing. The petition file is available for review at the Planning and Development Services Department offices located at 2300 Virginia Avenue, 2nd Floor, Fort Pierce, Florida, during regular business hours. Please call (772) 462-2822 or TDD (772) 462-1428 if you have any questions or require additional information about this petition. The Planning and Zoning Commission has the power to review and make a recommendation of approval or disapproval to the Board of County Commissioners on all matters within its jurisdiction. The proceedings are electronically recorded. PURSUANT TO SECTION 286.0105, FLORIDA STATUTES, if a person decides to appeal any final decision made with respect to a matter considered for approval at a meeting or hearing, he or she will need a record of the proceedings. For such purpose, he or she may need to ensure that a verbatim record of the proceedings is made, which record includes the testimony and evidence upon which the appeal is to be based. Upon the request of any party to the proceeding, individuals testifying during a hearing will be sworn in. Any party to the proceeding will be granted an opportunity to cross-examine any individual testifying during a hearing upon request. If it becomes necessary, a public hearing may be continued to a date certain. Anyone with a disability requiring accommodation to attend this meeting should contact the St. Lucie County Risk Manager at least forty-eight (48) hours prior to the meeting at (772) 462-1546 or T.D.D. (772) 462-1428. PLANNING AND ZONING COMMISSION ST. LUCIE COUNTY, FLORIDA /S/EDWARD LOUNDS, CHAIRPUBLISH DATE: Wednesday, July 3, 2024 Page 51 of 428 9.B. 2024-34380 PUBLIC HEARINGS - PLANNING & DEVELOPMENT SERVICES AGENDA REQUEST DATE: 7/18/2024 *RESOLUTION ITEM - PLANNED DEVELOPMENT QUASI-JUDICIAL ITEM? Yes TO: Board of County Commissioners PRESENTED BY: Kori Benton, Planning Manager SUBMITTED BY: Planning & Development Services SUBJECT: DLF Citrus (FKA Sunbrite Citrus) Planned Non-Residential Development (PNRD) Rezoning & Preliminary Plan BACKGROUND: DLF Packing, LLC, is proposing a Major Adjustment to the existing Conditional Use Permit to expand their 52,000 sq. ft. citrus packing facility, formerly known as Sun Brite Citrus, to accommodate new freezers, relocation of the loading docks, and expansion of the internal support areas. A concurrent Site Plan Adjustment is active with the Development Review Committee, requiring further certification and administrative approval. The 19.34-acre property is located at the northeast corner of Orange Avenue and Graves Road, within the AG- 5 (Agricultural-5) Zoning District and AG-5 (Agricultural-5) Future Land Use. The site is located outside the Urban Services Boundary (USB) and is currently served via an on-site well and septic systems. PREVIOUS ACTION: On July 28, 1992, the Board of County Commissioners approved Resolution CU 92-10 for a Conditional Use Permit and Major Site Plan to authorize a citrus packing house in the AG-5 Zoning District for a project known as Sunbrite Citrus. On June 16, 1994, the Community Development Director granted a Minor Adjustment to the Major Site Plan to relocate the accessible parking spaces and to amend the dimensions of the cannery. On July 5, 2022, the Board of County Commissioners approved a Transportation Impact Study Waiver for the DLP (AKA DLF) Citrus Site Plan & Conditional Use Adjustments pursuant to St. Lucie County Land Development Code (LDC) Section 11.02.09(A)(4)(a). On August 16, 2022, the Board of County Commissioners approved a Major Adjustment to the Conditional Use Permit, via Resolution 2022-144, to authorize a 33,245 sq. ft. expansion to the 51,000 sq. ft. citrus packing facility to accommodate new freezers, relocation of the loading docks, and expansion of the internal support areas. Page 52 of 428 On June 19, 2023, the Planning & Development Services Director authorized a Major Adjustment to a Site Plan via PDS Order 2023-037, to expand an existing 51,000 sq. ft. citrus packing facility by up to 33,245 sq. ft., formerly known as Sun Brite Citrus, to accommodate new freezers, relocation of the loading docks, and expansion of the internal support areas for their facility – aligning with the approved Conditional Use Permit (Adjustment). FINANCIAL IMPACT: N/A RECOMMENDATION: Staff recommends the Planning & Zoning Commission forward a recommendation of approval to the Board of County Commissioners, subject to conditions identified in the Draft Resolution enclosed. COMMISSION ACTION: RESULT: MOVER: None SECONDER: None AYES: None NAYS: None EXCUSED: None Coordination/Signatures Date: July 12, 2024 Benjamin Balcer, Planning & Development Services Director Date: July 12, 2024 Katherine Barbieri, Assistant County Attorney III Date: July 12, 2024 Mayte Santamaria, Deputy County Administrator Page 53 of 428 Planning and Development Services Department Planning Division M E M O R A N D U M GENERAL INFORMATION: Property Owner:DLF Packing LLC 150 N Graves RD Fort Pierce, FL 34945 Agent:Rebecca Grohall, AICP MBV Engineering, Inc. 1835 20th Street Vero Beach, Florida 32960 Location:150 N Graves Road Fort Pierce, FL 34945 Parcel ID: 2212-242-0001-000-8 Existing Use:Citrus Processing, Packaging & Wholesale Distribution, Including Cold Storage (Conditional Use Permit) Proposal:PNRD Rezoning to maintain active development plan, and allow future expansion Future Land Use:AG-5 (Agricultural-5) Current Zoning:AG-5, Agricultural-5 Proposed Zoning:PNRD (Planned Non-residential Development) Urban Services Boundary:Outside - Approximately 700 ft. west of the Urban Service Boundary Fire/EMS: Station #11 - Shinn Road, located 4.6 miles southeast of the subject site. Utility Service:Well & Septic TO:Planning and Zoning Commission THROUGH:Benjamin Balcer, AICP, Planning & Development Services Director FROM:Kori Benton, AICP, Planning Manager DATE:July 10, 2024 SUBJECT:DLF Citrus PNRD Zoning Atlas Amendment (Rezoning) & Preliminary PNRD Plan Page 54 of 428 DLF Citrus PNRD Page 2 Site Aerial BACKGROUND & ANALYSIS: DLF Packing, LLC, is proposing a Zoning Atlas Amendment (Rezoning) & Preliminary Planned Development Plan generally aligning with their active Conditional Use Permit and Site Plan for their citrus packing facility, formerly known as Sun Brite Citrus, which was recently authorize to expand the existing 51,000 sq. ft. facility by over 33,000 sq. ft. to accommodate new freezers, relocation of the loading docks, and expansion of the paved support areas. The proposed rezoning, from the AG-5 (Agricultural-5) Zoning District to the Planned Non-Residential Development (PNRD) Zoning District, would provide relief from the current 10% Lot (Building) Coverage Limit imposed by the AG-5 District for future expansion. The subject 19.34-acre property is located at the northeast corner of Orange Avenue and Graves Road, within the AG-5 (Agricultural-5) Future Land Use. The site is located outside the Urban Services Boundary (USB) and is currently served via on-site well and septic systems. Approval History •July 28, 1992 The Board of County Commissioners approved Resolution CU 92-10 for a Conditional Use Permit and Major Site Plan to authorize a citrus packing house in the AG-5 Zoning District for a project known as Sun Brite Citrus. •June 16, 1994 The Community Development Director granted approved a Minor Adjustment to the Major Site Plan to relocate the handicapped parking spaces and to amend the dimensions of the cannery. •On July 5, 2022, the Board of County Commissioners approved a Transportation Impact Study Waiver for the DLF Citrus Site Plan & Conditional Use Adjustments pursuant to St. Lucie County Land Development Code (LDC) Section 11.02.09(A)(4)(a). Page 55 of 428 DLF Citrus PNRD Page 3 •On August 16, 2024, the Board of County Commissioners approved a Major Adjustment to the Conditional Use Permit, via Resolution 2022-144, to authorize a 33,245 sq. ft. expansion to the 51,000 sq. ft. citrus packing facility to accommodate new freezers, relocation of the loading docks, and expansion of the internal support areas. ********************************************************************************* STAFF ANALYSIS In accordance with St. Lucie County Land Development Code (LDC) Sections 11.02.05, 11.06.03, and 11.02.07, 11.07.05(2)(b)(1), the proposed Zoning Atlas Amendment (Rezoning) & Preliminary Planned Development Plan aligning with the active Conditional Use Permit and Site Plan requires evaluation by the Planning & Zoning Commission and approval by the Board of County Commissioners. 1) ZONING ATLAS AMENDMENT STANDARDS OF REVIEW SET FORTH IN LAND DEVELOPMENT CODE SECTION 11.06.03 Proposed Zoning Designation Section 11.06.03 of the St. Lucie County Land Development Code establishes the standards for reviewing Zoning Atlas Amendments. In reviewing an application for a Zoning Atlas Amendment, the Board of County Commissioners shall consider the following: A. Whether the proposed rezoning conflicts with any applicable portions of the St. Lucie County Land Development Code: The proposed Amendment to the Official Zoning Atlas is not in conflict with the applicable provisions of the Land Development Code. The request seeks to amend the Official Zoning Atlas and reclassify Page 56 of 428 DLF Citrus PNRD Page 4 the zoning from the AG-5 (Agricultural – 5, 1du/5ac) to the PNRD (Planned Non-Residential Development) Zoning District. The Preliminary PNRD Rezone conforms with the requirements outlined under LDC Sections 7.02.02(B) – Permitted Uses, 11.09.02 (Table 11-1), Comprehensive Plan Future Land Use Element and the Consistency Matrix Table identified under Policy 1.1.1.3. The existing and proposed use(s) under the proposed PNRD are consistent with LDC Section 7.02.02. A., whereas, for “properties located in any Residential or Agricultural classified land use area: Any permitted, conditional or accessory use, including any standards, conditions and requirements for those uses, as identified in the Commercial, Neighborhood (CN); Commercial, Office (CO); Institutional (I) Zoning Districts, and in the Agricultural land use classified areas only, any non- residential permitted or accessory use identified in the Agriculture-1 (AG-1), Agricultural-2.5 (AG- 2.5), or Agricultural-5 (AG-5) zoning districts of this Code…” “The general standards, conditions and requirements, as found in this Code, that pertain to conditional and accessory uses shall be used in the determination of the compatibility of the proposed use(s) with the surrounding land uses in the review of the Planned Nonresidential Development. All applications for Planned Nonresidential Development shall include a complete identification of all planned uses and activities.” The active Conditional Use Permit for the facility will be retained, to provide for continued citrus processing, storage and distribution. The PNRD provides the opportunity for the facility, including any authorized expansion in the future, to exceed the AG-5 Zoning District’s 10% lot coverage limitation (per Table 7-10). B. Whether the proposed amendment is consistent with all elements of the St. Lucie County Comprehensive Plan: The proposed zoning reclassification from AG-5 to the PNRD Zoning District is consistent with the St. Lucie County Comprehensive Plan. Pursuant to the St. Lucie County Comprehensive Plan, the subject parcels are located within the AG- 5 (Agricultural-5) Future Land Use Category, with the existing facility supporting and maintaining agricultural and agricultural-related activities. Access to development will be maintain via Graves Road, from Orange Avenue (SR68), paved by the applicant through all access points. The Goals, Objectives, and Policies of the St. Lucie County Comprehensive Plan of emphasis in review of the proposed petition include: Future Land Use Element Objective 1.1.1: Land Use. Maintain the Future Land Use Map land with the following use designations to portray the future development patterns of St. Lucie County. Policy 1.1.1.2 - The County’s land use categories shall be described as follows: A. Agricultural-5 (AG-5) The AG-5 land use designation is intended for those areas of the County outside of the planned urban service area which are associated with agricultural and agricultural-related activities. These areas are recognized for first being appropriate for the production of citrus, cash crops, or ranching activities. These areas are acknowledged as potentially suitable for limited residential and nonresidential development under the following criteria: Page 57 of 428 DLF Citrus PNRD Page 5 • All residential and nonresidential development must be in accordance with applicable standards and restrictions as set forth in the Land Development Code; Objective 1.1.8: Planned Developments. The County shall continue to support and encourage innovative land use development patterns including planned developments through the adequate provision in the County's Land Development Code including Planned Unit Developments (PUD), Planned Non-Residential Development (PNRD) and the Planned Mixed-Use Development (PMUD) zoning designations. Policy 1.1.8.3: The County shall continue to support and implement the mixed-use activity areas as indicated in the Sub-area Mixed Use Activity Area Plans as depicted by name in this Element. Policy 1.1.10.2: Require effective visual and light diffusion barriers between residential and non-residential uses. Standards and requirements for such barriers are to be included in the landscaping and screening regulations of the St. Lucie County Land Development Code. Objective 1.1.13: Economic Sustainability. To enhance the quality of life of St. Lucie County and promote a sound and resilient local economy, St. Lucie County shall continue to work with the interested groups and agencies to increase and broaden the County's economic base while expanding existing business and industrial opportunities. Policy 1.1.13.1: St. Lucie County shall actively assist to the maximum extent practical in the recruitment of clean high growth industrial activities and maintain an expedited permitting process for bona fide economic development projects, especially those within the Targeted Industry List, and for development projects located within the Foreign Trade Zone. Policy 1.1.13.4: The County shall maintain procedures and incentive tools to encourage business development and assist economic development in St. Lucie County, especially for business within the Targeted Industry List. This goal shall be further implemented by developing innovative land use codes to provide an enhanced the quality of life for St. Lucie County and promote a sound, diverse and resilient local economy. Comprehensive Plan consistency review was affirmed with this review, with prior Conditional Use Permit and Site Plan Review, and will be required with any future Site Plan reviews. C. Whether and the extent to which the proposed zoning is inconsistent with the existing and proposed land uses: The proposed PNRD (Planned Non-Residential Development) Zoning District is consistent with the AG-5 Future Land Use designation with the Preliminary Plan detailing the use, layout framework, and district standards – consistent with the developed conditions of the site. The Planned Non-Residential Development (PNRD) District is intended to achieve non-residential land development of superior quality through the encouragement of flexibility and creativity in design options that: •Permit creative approaches to the development of non-residential land reflecting changes in the technology of land development. •Allow for the efficient use of land, which can result in smaller networks of utilities and streets and thereby lower development costs. Page 58 of 428 DLF Citrus PNRD Page 6 •Allow design options that encourage an environment of stable character, compatible with surrounding land uses. •Permit the enhancement of neighborhoods through the preservation of natural features, the provision of underground utilities, and the provision of recreation areas and open space. As noted, a lead purpose of the PNRD proposal is to provide relieve from the AG-5 Zoning District’s 10% lot coverage limitation (per Table 7-10). Under the current limitation, a portion of the pre-existing facility (~6,000 sq. ft.) would need to be demolished prior to a Certificate of Occupancy for the active expansion to maintain compliance with this 10% limitation. Even a modest 15% lot coverage limitation for the 19.34-acre property, would provide flexibility for future expansion proposals of roughly 40,000 sq. ft. beyond the current 84,245 sq. ft. plan (including finished and open air building coverage). D. Whether there have been any changed conditions that require an amendment. The applicant is completing a +/-35,000 sq. ft. facility expansion in accordance with the approved Conditional Use Permit and Site Plan, however with the current AG-5 dimensional limitation, a portion of the pre-existing facility (~6,000 sq. ft.) would need to be demolished prior to a Certificate of Occupancy for the active expansion. The proposed PNRD would provide relief for a Site Plan Adjustment to maintain portion of the facility’s open area, covered, operation space. The active expansion effort is to support on-site cold storage and citrus processing capacity, to allow DLF to vertically integrate business operations – keeping more of their activities here in St. Lucie County. E. Whether and the extent to which the proposed amendment would result in demands on public facilities, and whether or to the extent to which the proposed amendment would exceed the capacity of such public facilities, including but not limited to transportation facilities, sewage facilities, water supply, parks, drainage, schools, solid waste, mass transit, and emergency medical facilities. The proposed PNRD is not expected to cause adverse demands on public facilities, allowing maintenance of the adopted Level of Service (LOS) Standards as set forth in the St. Lucie County Land Development Code and Comprehensive Plan. The site is located less than one-quarter mile outside of the Urban Service Boundary (USB). Water/Wastewater: The site will continue to be served by a well and a septic system due to the absence of available central services. Traffic Analysis & Access The provided Traffic Statement, utilizing the Institute of Traffic Engineers’ 10th Edition Manual for a Warehousing Facility up to 90,000 sq. ft., projects 157 average daily trips to the site. Due to operation changes provided by the expansion, the prosposed project scope is anticipated to have a de Minimis impact on Orange Avenue (SR68) and associated roadway links, and may result in a decrease in traffic generated by the site. Main access to the facility is at Graves Road & Orange Avenue (SR 68). Daily traffic volumes along SR 68 at this location are low (AADT of 2700), per the latest published TPO Data. Additionally, Graves Road is served by a westbound right-turn lane from Orange Avenue to assist in efficient movement from Orange Avenue to the project site. Therefore, the approved project and current proposal scope will not greatly impact the immediate roadway network. Page 59 of 428 DLF Citrus PNRD Page 7 The approved project includes relocation of an access point to Graves Road further to the north, beyond the terminus of the full paved section improved with the original development. The applicant has permitted extension of the paved section of Graves Road to serve this new access point. F. Whether and the extent which the proposed amendment would result in significant adverse impacts on the natural environment: The proposed Zoning Amendment is not anticipated to create significant impacts on the natural environment. The applicant provided an Environmental Impact Report (EIR) that assesses existing environmental conditions on the subject property. The Environmental Resources Department reviewed the submitted and provided the following evaluation: Background: The Environmental Resources Department (ERD) is in receipt of the April 25, 2024, date-stamped submittal transmitted April 26, 2024, with comments due May 13, 2024, from Planning and Development Services. The applicant is proposing a zoning amendment application to change the zoning designation from Agricultural - 5 (AG-5) to Planned Non-Residential Development (PNRD) to allow relief from the ten percent (10%) building coverage attributed to Agricultural zoning districts. The 19.34-acre subject site (Parcel ID 2212-242-0001-000-8) is located at 150 N. Graves Rd with a future land use of Agricultural – 5 (AG-5). Findings: The northern portion of the site was historically utilized as a spray field/tree nursery according to provided plans. The previously approved project will impact 2.27 acres of the site. DLF Citrus has been in operation since 1991. Numerous native trees, predominantly live oak, laurel oak, and cabbage palms meeting mitigation thresholds do exist onsite. See specific Site Design and Landscape Plan Findings below, in Section 2. D. Recommendation: The Environmental Resources Department has no objection to the proposed Rezone petition. G. Whether and the extent to which the proposed amendment would adversely affect property values in the area. The proposed zoning change is not anticipated to have an adverse impact on property values in the area. The amendment requires concurrent site plan review, with approved plans in-place and construction underway, with the plan supporting development of stable character and compatibility with the surrounding land uses. H. Whether and the extent to which the proposed amendment would result in an orderly and logical development pattern specifically identifying any negative effects of such patterns. The proposed zoning and maintained agricultural uses would result in an orderly and logical pattern in the nearby vicinity, which consists of a variety of agricultural, non-residential uses and ag residences. The available roadway access, and proximity to agricultural product sources aligns with the County’s Comprehensive Plan. Page 60 of 428 DLF Citrus PNRD Page 8 I. Whether the proposed amendment would conflict with the public interest and is in harmony with the purpose and intent of this Code. The proposed amendment would not conflict with the public interest and is in harmony with the purpose and intent of the St. Lucie County Land Development Code. J. Any other matters that may be deemed appropriate by the Planning and Zoning Commission or the Board of County Commissioners, in review and consideration of the proposed amendment. The Planning and Zoning Commission and Board of County Commissioners may raise other matters regarding this proposed amendment to the Official Zoning Atlas. ANALYSIS SUMMARY: Based upon staff’s analysis contained in this report, the proposed rezoning from AG-5 (Agricultural – 5, 1du/5ac) to the PNRD (Planned Non-Residential Development) is consistent with the St. Lucie County Comprehensive Plan and Land Development Code. 2) PRELIMINARY/FINAL PUD SITE PLAN STANDARDS OF REVIEW SET FORTH IN LAND DEVELOPMENT CODE SECTION 11.02.07 Consistency with Land Development Code and Comprehensive Plan The Development Review Committee has reviewed the proposed Preliminary PNRD Site Plan, which coincides with the approved Site Plan and Conditional Use Permit, finding it to be consistent with the general purpose, goals, objectives, and standards of the St. Lucie County Land Development Code (LDC) and Comprehensive Plan. Land Development Code: The subject property is currently zoned AG-5, Agricultural-5 which is consistent with the AG-5, Agricultural-5 Future Land Use category. Pursuant to LDC Section 3.01.03(C)(7) e. farm products warehousing and storage (4221/4222) are eligible Conditional Uses in the AG-5 zoning district, and is permissible under the proposed PNRD. In 1992, the Board of County Commissioners granted the original Conditional Use Permit and Major Site Plan to authorize the citrus processing and packing facility in the AG-5 Zoning District for a project known as Sun Brite Citrus. Design Through acquisition and desire to veritically integrate processing operations, including cold storage, DLF secured approval to complete a nearly 34,000 sq. ft. building addition, expand truck loading bays, trailer staging and facility storage. The proposed expansion complies with setbacks and height requirements for the AG-5 District. The proposed expansion reaches the maximum 10% building coverage in the AG-5 District, however the proposed PNRD seeks to provide relief from this standard, initially to a 10.29% lot coverage ratio to avoid demolition or removal of existing floor area to support the expansion under construction. Alternatively, compliance was to be achieved by marginally reducing the scale of the facility expansion, eliminating small accessory structures on site, and/or eliminating covered concrete areas – which is said to cause a financial and operational burden. The design provides minimum parking, loading and similar support improvements. The County’s Community Architectural Standards, LDC Section 7.10.24, would apply to this PNRD for any future development. These standards include building design, foundational landscape plantings, and similar enhancements, not required in the current AG-5 District. Page 61 of 428 DLF Citrus PNRD Page 9 Stormwater Site drainage will be accommodated through existing wet and dry retention areas, and an additional 1.11 +/- acre dry retention area. The property is not located within a Special Flood Hazard Area per the Flood Insurance Rate Map (FIRM). Landscaping The approved Landscape Plan coupled with the recent Site Plan and Conditional Use Adjustment align with the County’s requirements, as detailed in Subsection D., below. Comprehensive Plan: The proposal supports expansion of a local business and citrus processing facility, offering capital investment, new employment and support of the following Comprehensive Plan objectives and corresponding policies: Objective 1.1.13: Economic Sustainability. To enhance the quality of life of St. Lucie County and promote a sound and resilient local economy, St. Lucie County shall continue to work with the interested groups and agencies to increase and broaden the County's economic base while expanding existing business and industrial opportunities Policy 1.1.13.1 - St. Lucie County shall actively assist to the maximum extent practical in the recruitment of clean high growth industrial activities and maintain an expedited permitting process for bona fide economic development projects, especially those within the Targeted Industry List, and for development projects located within the Foreign Trade Zone. Policy 1.1.13.6 – The County shall support the expansion and recruitment of specialized and/or export-oriented manufacturing industries, which provide higher wage employment opportunities and encourage the development of ‘secondary’ product sector industry and employment. The facility expansion, associated logistics and distribution capacity to export citrus across Florida and throughout the country is supported by our Comprehensive Plan. Objective 10.1.1: Develop and implement activities designed to improve the overall prosperity of St. Lucie County and its residents. Policy 10.1.1.2 - Encourage redevelopment projects and business expansions that will promote economic development opportunities. This project continues use of private and public investment in the Orange Avenue corridor, with access to the I-95 interchange and state highway network, to support will provide business and employment growth for expectantly long-term job creation in the County. Objective 10.2.1: Support efforts to diversify St. Lucie County’s economy and to make the county an effective competitor. Policy 10.2.1.2 - Recruit businesses from the target industry sectors that will provide year-round employment opportunities. Policy 10.2.1.3 - Identify locations for and encourage development of economic clusters for business and industry that would benefit from being located near related industries in the area as well as for other desired contributory business users with the potential for significant employment. The project will provide expanded employment opportunities, increased ad-valorem tax revenue, and expand local and regional distribution services within an emphasized industry category. The proposal is consistent with local ordinances and the County’s Comprehensive Plan. Page 62 of 428 DLF Citrus PNRD Page 10 A. Effect on Nearby Properties The proposed plan, aligning with the approved Site Plan, should not have an adverse affect on nearby properties, the character of the agricultural neighborhood, traffic conditions, and other matters affecting the public health, safety, and general welfare. The properties to the north, south and west are also zoned AG-5 (Agricultural – 5, 1du/5ac), many of which remain undeveloped. To the east, a single-family home exists on a large lot in the AG-5 District, with a communications tower previously established in the abutting U, Utilities zoning district. Land Use and Zoning Snapshot: The expansion plan encompasses an addition to the west, fronting Graves Road, while expanding truck loading, staging and stormwater improvements to the north and northeast. Expanded stormwater is undeway along the east side of the new parking area to maintain some buffering between the facility and the existing residence, as displayed in Exhibit 1. The buffer will contain a landscape hedge and trees, with a partial waiver granted by the adjacent property owner to reduce the opaque fence requirement. B. Adequacy of Public Facilities The PNRD Plan, which aligns with the active site plan, is not expected to cause adverse demands on public facilities, allowing maintenance of the adopted Level of Service (LOS) Standards as set forth in the St. Lucie County Land Development Code and Comprehensive Plan. The site is located less than one-quarter mile outside of the Urban Service Boundary (USB). Water/Wastewater: The site will continue to be served by a well and a septic system due to the absence of available central services. Traffic Analysis & Access The provided Traffic Statement, accepted for the active Site Plan and Conditional Use Permit, utilized the Institute of Traffic Engineers’ 10th Edition Manual for a Warehousing Facility up to 90,000 sq. ft., and projects 157 average daily trips to the facility. Due to operation changes provided by the expansion, the prosposed project scope was acknowledged to have a de minimis impact on Orange Avenue (SR68) and associated roadway links, and may Location Zoning District(s)Future Land Use Existing Land Use(s) Subject Property AG-5, Agricultural-5 AG-5 (Agricultural-5)Citrus Processing, Packing & Wholesale Distribution North AG-5, Agricultural-5 AG-5 (Agricultural-5)Undeveloped/Misc. Ag South AG-5, Agricultural-5 AG-5 (Agricultural-5)Storage Depot Center East AG-5, Agricultural-5 / U, Utilities AG-5 (Agricultural-5) Farm Estate / Wireless Communications Tower Adjacent Parcels West AG-5, Agricultural-5 AG-5, (Agricultural-5)Undeveloped Exhibit 1: Landscape Plan Snapshot Page 63 of 428 DLF Citrus PNRD Page 11 result in a decrease in traffic activity. Main access to the facility is at Graves Road & Orange Avenue (SR 68). Daily traffic volumes along SR 68 at this location are low (AADT of 2700), per the latest published TPO Data. Additionally, Graves Road is served by a westbound right-turn lane from Orange Avenue to assist in efficient movement from Orange Avenue to the project site. Therefore, the proposed development will not greatly impact the immediate roadway network. The project underway includes relocation of an access point to Graves Road further to the north, beyond the terminus of the full paved section improved with the original development. The applicant has permitted, and will extend the paved section of Graves Road to serve this new access point. C. Adequacy of Fire Protection The site will be served by Fire Station #11, at 3501 Shinn Rd, Fort Pierce, FL 34945, which is located approximately 4.5 miles or a 6 minute travel time to the subject site. D. Environmental Impact Previously approved plans for the Major Adjustment to Major Site Plan (SPMj-4202126010-26010) were found to be in accordance with the Land Development Code, and will remain with this PNRD. The northern portion of the site was historically utilized as a spray field/tree nursery according to provided plans. The previously approved project will impact 2.27 acres of the site. A dry retention area will be constructed and serve as barrier between the proposed trailer parking and tree nursery that will remain post-impact. DLF Citrus has been in operation since 1991. Numerous native trees, predominantly live oak, laurel oak, and cabbage palms meeting mitigation thresholds do exist onsite. An eight (8) ft. tall wall waiver application for the eastern perimeter was provided and approved by ERD staff. A revised landscape plan prepared by Patrick D. Cunningham (LA-0001669) of Patrick D. Cunningham, LLC. dated May 3, 2023, was reviewed and determined to meet the standards outlined in LDC 7.09.00. Recommendation ERD has no objection to the approval of the preliminary planned development application. STAFF RECOMMENDATION: Staff recommends the Planning & Zoning Commission forward a recommendation of approval to the Board of County Commissioners, subject to the following conditions: 1. The PNRD shall not exceed a maximum 20% Lot Coverage. 2. Prior to commencement of development, including but not limited to; clearing, filling, excavation, grading, or planting of vegetation, as defined in LDC 2.00.00, a vegetation removal permit or exemption shall be issued by the Environmental Resources Department per LDC 6.00.03. 3. Prior to issuance of a Certificate of Occupancy, all Category I listed invasive species shall be eradicated from the site. Page 64 of 428 File No. PD-2404-000040 Resolution No. 2024-XX Page 1 Resolution 2024-XXX File No. PD-2404-000040 A RESOLUTION OF THE BOARD OF COUNTY COMMISSIONERS OF ST. LUCIE COUNTY AMENDING THE OFFICIAL ZONING ATLAS FROM THE AGRICULTURAL-5 (AG-5) ZONING DISTRICT TO THE PLANNED NON- RESIDENTIAL DEVELOPMENT (PNRD) ZONING DISTRICT AND APPROVING A PRELIMINARY DEVELOPMENT PLAN, MAINTAINING AN EXISTING CONDITIONAL USE PERMIT ON +/-19.34 ACRES LOCATED WITHIN ST. LUCIE COUNTY, FLORIDA. WHEREAS, the Board of County Commissioners of St. Lucie County, Florida, based on the testimony and evidence, including but not limited to findings in the staff report, has made the following determinations: ZONING ATLAS AMENDMENT & PRELIMINARY PNRD SITE PLAN 1. DLF Packing, LLC, petitioned a Zoning Atlas Amendment (Rezoning) and associated Preliminary Planned Development Plan generally aligning with their active Conditional Use Permit and Site Plan for their citrus packing facility, formerly known as Sun Brite Citrus, which was recently authorized to expand the existing 51,000 sq. ft. facility by over 33,000 sq. ft. to accommodate new freezers, relocation of the loading docks, and expansion of the paved support areas. The proposed rezoning, from the AG-5 (Agricultural-5) Zoning District to the Planned Non-Residential Development (PNRD) Zoning District, includes relief from the current 10% Lot (Building) Coverage Limit imposed by the AG-5 District for future expansion, on property legally described in Part “A” and depicted on the attached map as Exhibit “A”. 2. On July 18, 2024, the St. Lucie County Planning and Zoning Commission held a public hearing on this petition, after publishing notice in the St. Lucie News Tribune at least 10 days prior to the hearing, installing a sign on the subject property, and notifying by mail all owners of property within 500 feet of the subject property, at which time, all interested persons were given an opportunity to be heard and voted to forward a recommendation of _______ to the Board of County Commissioners for the property described in Part “A”. 3. On June 16, 1994, the Community Development Director granted approved a Minor Adjustment to the Major Site Plan to relocate the handicapped parking spaces and to amend the dimensions of the cannery. 4. On July 5, 2022, the Board of County Commissioners approved a Transportation Impact Study Waiver for the DLP (AKA DLF) Citrus Site Plan & Conditional Use Adjustments pursuant to St. Lucie County Land Development Code (LDC) Section 11.02.09(A)(4)(a). 5. On August 16, 2022, the Board of County Commissioners approved a Major Adjustment to the Conditional Use Permit, via Resolution 2022-144, to authorize a 33,245 sq. ft. expansion to the 51,000 sq. ft. citrus packing facility to accommodate new freezers, relocation of the loading docks, and expansion of the internal support areas. 6. On June 19, 2023, the Planning & Development Services Director authorized a Major Adjustment to a Site Plan via PDS Order 2023-037, to expand an existing 51,000 sq. ft. citrus packing facility by up to 33,245 sq. ft., formerly known as Sun Brite Citrus, to accommodate new freezers, relocation of the loading docks, and expansion of the internal Page 65 of 428 File No. PD-2404-000040 Resolution No. 2024-XX Page 2 support areas for their facility – aligning with the approved Conditional Use Permit (Adjustment). 7. On September 3, 2024, the Board of County Commissioners held a public hearing on this petition after publishing notice in the St. Lucie News Tribune at least 10 days prior to the hearing, installing a sign on the property and notifying by mail all owners of property within 500 feet of the subject property, at which time all interested persons were given an opportunity to be heard. 8. On July 28, 1992, the Board approved Resolution 92-103, granting a Conditional Use Permit for Sun Brite Citrus to develop a 45,100 sq. ft. warehouse and 3,750 sq. ft. office for a Citrus Packing operation, after holding a public hearing on the petition, after publishing a notice at least 10 days prior to the hearing and notifying by mail all owners of property within 500 feet of the subject property, at which all interested persons were given an opportunity to be heard. 9. The Development Review Committee has reviewed the proposed Major Adjustment and found it to be in substantial conformity with the existing Conditional Use. 10. St. Lucie County Planning and Development Services staff has performed the required land use analysis for this application. 11. The PNRD Rezoning and the associated Preliminary Plan, with the conditions therein, is/is not consistent with the goals, objectives, and policies of the St. Lucie County Comprehensive Plan and has satisfied the requirements of Section 11.07.03 of the St. Lucie County Land Development Code. 12. The project, with conditions therein, will not have an undue adverse effect on adjacent property, the character of the neighborhood, traffic conditions, parking, utilities, or other matters affecting the public health, safety, and general welfare. 13. The proposed project will be serviced by adequate public facilities and services. 14. The Certificate of Capacity as required under Chapter V, St. Lucie County Land Development Code, shall be maintained or require modification with any associated Site Plan Adjustment. NOW, THEREFORE, BE IT RESOLVED by the Board of County Commissioners of St. Lucie County, Florida: A. The property on which the Zoning Atlas Amendment, or change in zoning, from AG-5 (Agricultural-5) to PNRD (Planned Non-Residential District), is being granted is described as follows: Legal Description: The West 1/2 of the Southeast 1/4 of the Northwest 1/4 of Section 12, Township 35 South, Range 38 East, St. Lucie County, Florida, less and excepting 25 foot right of way for Graves Road as recorded in Deed Book 77, Page 27B, also less and except the East 10 feet of the West 35 feet of the West 1/2 of the Southeast 1/4 of the Northwest 1/4 as recorded in O. R. Book 869, Page 8, of the Public Records of St. Lucie County, Florida. Parcel ID#: 2213-242-0001-000-8 B. Pursuant to St. Lucie County Land Development Code (LDC) Sections 11.02.05, 11.06.03, and 11.02.07, 11.07.05(2)(b)(1), the proposed Zoning Atlas Amendment (Rezoning) & Page 66 of 428 File No. PD-2404-000040 Resolution No. 2024-XX Page 3 associated Preliminary Planned Development Plan aligning with the active Conditional Use Permit and Site Plan, approved by Resolution 92-103 and subsequently amended by Resolution 2022-144, for the property described in Paragraph C is hereby approved/denied as generally shown on the drawings for the project prepared by MBV Engineering dated January 1, 2023, subject to the following conditions: 1. The PNRD shall not exceed a maximum 20% Lot Coverage. 2. Prior to commencement of development, including but not limited to; clearing, filling, excavation, grading, or planting of vegetation, as defined in LDC 2.00.00, a vegetation removal permit or exemption shall be issued by the Environmental Resources Department per LDC 6.00.03. 3. Prior to issuance of a Certificate of Occupancy, all Category I listed invasive species shall be eradicated from the site. C. The St. Lucie County Planning and Development Services Director shall be authorized to amend the Official Zoning Map to change the zoning of the property herein described, from AG-5 (Agricultural-5) to PNRD (Planned Non-Residential District) and to make notation of the reference to the date of adoption of this Resolution. D. The approvals and authorizations granted by this Resolution are for the purpose of operating and providing potential for future expansion of an existing citrus packing and distribution facility which holds an active Conditional Use Permit within St. Lucie County and are not assigned to any other party or institution. Should the petitioners choose or decide to assign this operation to another entity or individual, a minor adjustment to the associated Conditional Use Permit shall be required in accordance with the provisions of the Land Development Code. E. The approvals and authorizations granted by this Resolution are for the purpose of obtaining a Site Plan Adjustment, Building Permit and/or Zoning Compliance from St. Lucie County, and are not assigned to any other party or institution, unless an associated Conditional Use Adjustment is authorized. F. The Preliminary Planned Non-Residential Development Site Plan approval granted by this Resolution shall be valid until September ___, 2026 unless the existing Final (Minor) Site Plan is fulfilled or an adjustment thereof is authorized, or an extension is granted in accordance with Section 11.02.06(B)(3) of the Land Development Code. G. The developer is advised as part of this approval, including any successors in interest, the developer shall obtain all applicable development permits and construction authorizations from the appropriate state and federal and local regulatory agencies including, but not limited to, the United States Army Corps of Engineers, the Florida Department of Environmental Protection, and South Florida Water Management District, and the St. Lucie County Environmental Resources, Public Works and Building Departments prior to the commencement of any development activities on the property described in Part “A”. Issuance of this permit by the County does not in any way create any rights on the part of the developer to obtain a permit from a State or Federal agency and does not create any liability on the part of the County for issuance of this permit if the developer fails to obtain requisite approvals or fulfill the obligations imposed by a state or federal agency or undertake actions that may result in a violation of State or Federal law. Page 67 of 428 File No. PD-2404-000040 Resolution No. 2024-XX Page 4 H. The St. Lucie County Planning and Development Services Director is hereby authorized and directed to cause the notation of this resolution to be made on the Official Zoning Map of St. Lucie County, Florida, including rezoning of the parcel, and to make notation of reference to the date of adoption of this resolution. I. The conditions set forth in Part “B” are an integral non-severable part of the approval granted by this Resolution. If any condition set forth in Part “B” is determined to be invalid or unenforceable for any reason and the applicant or property owner declines to comply voluntarily with that condition, the approval granted by this Resolution shall become null and void. J. This Resolution shall become effective upon the date indicated below. An appeal of the Board of County Commissioners’ action may be processed within thirty (30) days in accordance with Section 11.11.02.F, of the St. Lucie County Land Development Code. K. A copy of this Resolution shall be mailed to the owner of record as identified on the application. L. This Resolution shall be recorded in the Public Records of St. Lucie County. M. Adoption After motion and second, the vote on this resolution was as follows: Cathy Townsend, Chair XXX Chris Dzadovsky, Vice-chair XXX Larry Leet, Commissioner XXX Linda Bartz, Commissioner XXX Jamie Fowler, Commissioner XXX PASSED AND DULY ADOPTED this 2nd day of September, 2024. BOARD OF COUNTY COMMISSIONERS ST. LUCIE COUNTY, FLOIRDA BY Chair ATTEST: APPROVED AS TO FORM AND CORRECTNESS: ______________ _____________________ DEPUTY CLERK COUNTY ATTORNEY Page 68 of 428 File No. PD-2404-000040 Resolution No. 2024-XX Page 5 Exhibit “A” (Location Map) Page 69 of 428 Page 70 of 428 Page 71 of 428 Page 72 of 428 Page 73 of 428 50' FRONT BUILDING SETBACK LINE 30' REAR BUILDING SETBACK LINE 20 ' S I D E B U I L D I N G S E T B A C K L I N E 20 ' S I D E B U I L D I N G S E T B A C K L I N E 15' LANDSCAPE BUFFER 15 ' L A N D S C A P E B U F F E R 10' LANDSCAPE BUFFER 10 ' L A N D S C A P E B U F F E R EXISTING BUILDING EXPANSION 38,225 S.F. F.F.E.= 27.00 PROP. DRY RETENTION 1.11 AC PROPOSED DUMPSTER ENCLOSURE LOADING SPACE TRUCK CIRCULATION AREA LOADING SPACE LOADING SPACE LOADING SPACE LOADING SPACE LOADING SPACE (60' R / W) (R / W W I D T H V A R I E S , 1 2 0 ' - 1 3 8 ' ) 60 ' R / W CITRUS CRATE DROP-OFF & EMPTY BOX STORAGE GROVE MAINTENANCE AREA12 0 ' 125' 125' OOOO O O O O O O O O EXISTING ASPHALT TO BE MILLED AND RESURFACED 20 . 0 20 . 0 21 . 0 21 . 0 21 . 0 21 . 0 20 . 0 20 . 0 19 . 5 19 . 5 19 . 5 19 . 5 21.0 20.0 19.5 21.020.019.5 40' 145' 33 6 ' T R A I L E R P A R K I N G 28 55'70' 30' R50'R50' R70' R35' 13 . 6 7 ' 65' R50' R25' R45' R45' R50' 190' 21 8 . 6 7 ' 50 . 3 2 ' 716.43' 50 . 0 4 ' 97 . 3 6 ' R25' 633.5' 200' 55' 6 7 10 6 15 15 6 10 CONDENSOR ON CONC. PAD, TYP. CONDENSOR ON CONC. PAD, TYP. 158.33' 19 2 . 8 3 ' EXISTING SPRAY FIELD / TREE NURSERY TO REMAIN (APPROXIMATELY 3.50 ACRES) PROP. 5' CONC. WALK, TYP. EXISTING SITE LIGHTING TO REMAIN 12 ' 40'50.3' 11 5 ' 145' 12 ' 26 '26 ' 449.98' EXISTING SPRAY FIELD TO REMAIN UNDISTURBED UNLESS OTHERWISE NOTED PROP. 7' FENCE PROP. 7' FENCE 3FT FROM ASPHALT PROP. 7' FENCE PROP. 7' FENCE TO REPLACE EXISTING CHAIN LINK FENCE PROP. 7' FENCE 2' FROM LANDSCAPE BUFFER PROP. 7' FENCE 2' FROM LANDSCAPE BUFFER PROP. ACCESS CONTROL FENCE W/ GATE PROP. GATED ENTRY DOUBLE-SWING GATE (28' WIDE) PROP. GATED ENTRY DOUBLE-SWING GATE (46' WIDE) PROP. GATED ENTRY DOUBLE-SWING GATE (36' WIDE) 39 . 3 5 ' 28' 39 . 4 ' 46'36' 23 . 8 9 ' 24 . 6 9 ' 23 . 3 5 ' 23 . 6 ' 23 . 8 4 ' R5' 6 PROPOSED LANDSCAPE ISLAND 12 PROPOSED LITTORAL PLANTINGS. REFER TO LANDSCAPE PLANS. PROP. WIDENING OF ROAD TO 24' PROPOSED CONCRETE WHEEL-STOPS PROPOSED ROAD IMPROVEMENTS PER ST. LUCIE COUNTY STANDARDS (STA. 16+10.4 TO STA. 18+61.8) EXISTING CONCRETE PROPOSED STABILIZED GRAVEL LEGEND PROPOSED HEAVY DUTY ASPHALT EXISTING ASPHALT C4 SI T E P L A N 3/ 2 8 / 2 0 2 4 Know what'sbelow. before you dig.Call R 72 HOURS BEFORE DIGGING CALL TOLL FREE 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 0 50 100 50 SITE PLAN SCALE: 1" = 50'SHEET 1 FL O R I D A RE V I S I O N S DA T E DE S I G N E D DR A W N DA T E CH E C K E D DA T E I S S U E D WF P GW R FE B R U A R Y 2 0 2 2 AJ B JO B N O . 2345678 18 3 5 - 2 0 T H S T R E E T VE R O B E A C H , F L 3 2 9 6 0 PH . ( 7 7 2 ) 5 6 9 - 0 0 3 5 FX . ( 7 7 2 ) 7 7 8 - 3 6 1 7 MO I A B O W L E S V I L L A M I Z A R & A S S O C I A T E S CO N S U L T I N G E N G I N E E R I N G C A # 3 7 2 8 ME L B O U R N E , F L - P H ( 3 2 1 ) 2 5 3 - 1 5 1 0 FT . P I E R C E , F L - P H ( 7 7 2 ) 4 6 8 - 9 0 5 5 C: \ C I V I L O N H A R D D R I V E \ 2 0 2 1 \ 2 1 - 0 2 0 6 D L F P a c k i n g h o u s e E x p a n s i o n - S i t e \ D W G \ 2 1 - 0 2 0 6 C 4 S I T E P L A N . d w g 3/ 2 8 / 2 0 2 4 9 : 3 6 AM GR E G G R E E D 21-0206 ST . L U C I E C O U N T Y DL F P L A N N E D D E V E L O P M E N T ( P N R D ) 21 - 0 2 0 6 01 - 0 1 - 2 0 2 3 BO C C C O N D I T I O N O F A P P R O V A L 04 - 2 6 - 2 0 2 3 CO U N T Y C O N D I T I O N S 05 - 0 8 - 2 0 2 3 RE L O C A T E A D A P E R B U I L D I N G D E P T . 06 - 0 1 - 2 0 2 3 RE V I S I O N S P E R S F W M D 06 - 1 6 - 2 0 2 3 PE R S T . L U C I E C O U N T Y _ _ _ _ _ _ A JARON BWOL. No. 55313 STATE OF ROFL ADl R FO R P lSSE ANO lNEE E N GL ENSEClL AARON J. BOWLES FL. P.E. #55313 ES SIGNAGE & PAVEMENT MARKING SCHEDULE SIZESIGN ID NUMBER 1 2 DESIGNATION / NOTES 3 30"R1-1 "STOP" SIGN SOLID WHITE STOP BAR24" PAVEMENT MARKINGS PER FDOT INDEX #711-001 * ALL STRIPING WITHIN 25' OF ST. LUCIE COUNTY R / W TO BE THERMOPLASTIC 1 1 22 3 3 3 PROPOSED CONCRETE NOTES: 1. REFER TO EROSION CONTROL PLAN FOR EROSION CONTROL DETAILS. PROPOSED ASPHALT (RIGHT-OF-WAY) 4 FTP-20-06 HC PARKING SIGN, SEE DETAIL SHEET C612" 4 4 3 3 6 Page 74 of 428 5/9 / 2 3 Page 75 of 428 5/9 / 2 3 Page 76 of 428 OOOO OOOO O O O O O O O O RETENTION POND 1.32 AC @ CONTROL ELEV. = 17.8 NAVD SH E E T L 2 SH E E T L 3 91 1105 90 104 1088 1087 1089 1091 1092 1093 1094 1095 1096 1097 1148 1150 1151 1149 1098 11001099 110111021103 1107 1106 1111 1153 1152 WASHWATER REUSE POND 0.31 AC @ CONTROL ELEV. = 17.8 NAVD DRY RETENTION POND 0.50 AC PROPOSED DRY RETENTION POND 1.11 AC CITRUS CRATE DROP-OFF & EMPTY BOX STORAGE PROPOSED BUILDING EXPANSION 34,330 SF F.F.E.= 27.0 EXISTING BUILDING 50,904 SF F.F.E.= 23.3 NORTH GRAVES ROAD OR A N G E A V E N U E CO U N T R Y R O A D N O . 6 8 GROVE MAINTENANCE AREA SPRAY FIELD / TREE NURSERY (TO BE UNDISTURBED) UNDERGROUND UTILITIES OVERHEAD UTILITIES OVERHEAD UTILITIES OVERHEAD UTILITIES OVERHEAD UTILITIES SOUTH BUFFER RIGHT-OF-WAY BUFFER 15' WIDE BUFFER (1) TREE / 30 LF 24" HEDGE, 30" AFTER 18MO EAST BUFFER PERIMETER BUFFER 10' WIDE BUFFER (1) TREE / 30 LF 4' HEDGE, 6' IN 18 MO WEST BUFFER RIGHT-OF-WAY BUFFER 15' WIDE BUFFER (1) TREE / 30 LF 24" HEDGE, 30" AFTER 18MO 15' SAFESIGHT TRIANGLE 15' SAFESIGHT TRIANGLE 15' SAFESIGHT TRIANGLE 15' SAFE SIGHT TRIANGLE 15' SAFESIGHT TRIANGLE30' SAFE SIGHT TRIANGLE SIGN 92 93 94 95 96 108 107 1104 1142 1143 1144 1145 1024 1025 1039 1023 1032 1022 1021 98 99 870 871 872873874 100 101102 103 12 15 1314 23 22 16 21 34 3536 37 20 19 18 17 42 43 41 46 38 39 40 44 45 61 49 47 57 58 72 71 70 59 60 62 6667 6869 65 64 77 78 79 80 81 82 11 86 2 1 85 8384 8 7 9 10 6 63 1074 1076 1075 10771078 1073 1054 1055 1056 1079 1043 1072 1080 1050 1052 1051 1053 1049 1046 1048 1047 1045 1044 1042 1057 106810701071 1003 1006 1016 10151017 1019 1033 1020 1036 1031 10281038 1037 1082 1083 1061 1084 990 1065 991 984 939 935 912 920 893 867 868869 886 887 888884 883 882881 896 895 894 905 892 891890 889 904 919 923 956 953 952 950 949 948 947 932 918 917915 933 914 911 910 906908 909 907 934 936 937 985 986 989987988 983 940941945946942 944 943 982 981980 979 993 1086 978977 976 996 1067 992 1035 1066 10631062 1060 1064 1035 1034 1027 1026 885 994 1030 1029 1112 113114 112 111110109 938 SH E E T L 5 SH E E T L 6 LESS 246.3' UNDISTURBED AREA LESS 281.8' UNDISTURBED AREA 105 106 LITTORAL PLANTING & UPLAND TRANSITION ZONE PER FLORIDA ENVIRONMENTAL CONSULTING, INC. (FEC) LI M I T S O F W O R K (A P P R O X . ) PROPOSED WAIVER: OPAQUE WALL/FENCE WAIVER FOR THIS AREA ADJACENT TO RESIDENTIAL. (APPROX. 640 LF) (TO BE DETERMINED) SHE E T L 2 SHE E T L 3 NORTH GRAVES ROAD OR A N G E A V E N U E CO U N T R Y R O A D N O . 6 8 SH E E T L 5 SH E E T L 6 LIM I T S O F W O R K (AP P R O X . ) 1" = 5 0 ' - 0 " 0 50 10 0 DELINEATES MATERIAL ON THE COUNTY'S PREFERRED SPECIES LIST. NOTE: PER SEC. 7.09.03.E., ALL TREES CALIPERS ARE TO BE MEASURED AT 4.5-FT ABOVE GRADE (DBH) AT INSTALLATION . - NO EXCEPTIONS. KEY L-2 L-1 L-3 Landscape Calculations REQUIRED/ PERMITTED PROVIDED LANDSCAPE BUFFERS RIGHT-OF-WAY BUFFER WEST BUFFER (NORTH GRAVES ROAD) - 15' WIDE BUFFER 1,049 LF (1331 LF - 282 LF) = (1) TREE / 30 LF 35 TREES 53 TREES INCL.:(12) TREES (21) PALMS @ 3:1 = 7 TREES (13)EXISTING TREES - 34 TREE CREDITS HEDGE @ 24" HT, MIN, 30" HT. AFTER 18 MONTH SOUTH BUFFER (ORANGE AVENUE) - 15' WIDE BUFFER 629 LF (1) TREE / 30 LF 21 TREES 23 TREES INCL.:(18) TREES (1)EXISTING TREE = 4 TREE CREDITS (4)EXISTING PALMS @ 1:3 = 1 TREE CREDIT HEDGE @ 24" HT, MIN, 30" HT. AFTER 18 MONTHS PERIMETER LANDSCAPE BUFFERS EAST BUFFER - 10' WIDE BUFFER 1,084 LF (1330 LF - 246 LF) = (1) TREE / 30 LF 37 TREES 55 TREES INCL.:(31) TREES (5)EXISTING TREE = 23 TREE CREDITS (3)EXISTING PALMS @ 1:3 = 1 TREE CREDIT HEDGE @ 4' HT, MIN, 6' HT. AFTER 18 MONTHS OPAQUE WALL/FENCE: PROPOSED WAIVER - (APPROX. 640 LF)T.B.D VEHICULAR USE AREA INTERIOR LANDSCAPE AREA VEHICLE USE AREA (VUA)128,256 SF INTERIOR LANDSCAPE AREA: 1 SF/18 SF VUA 7,126 SF 17,597 SF (1) TREE / 180 SF = 40 TREES 46 TREES INLUDES:(14) TREES (11)EXISTING TREES - 32 TREE CREDITS BUILDING PERIMETER (BUILDING FOR FOOD PRODUCTION) WEST, SOUTH & EAST SIDES 988 LF (1) TREE / 30 LF 33 TREES 33 TREES INLUDES:(17) TREES (18) PALMS @ 3:1 = 6 TREES (3)EXISTING TREES - 10 TREE CREDITS Additional Requirements REQUIRED/ PERMITTED PROVIDED NATIVE & DROUGHT TOLERANT REQUIREMENTS (AS PER SECTION 7.09.04(L) TREES - 100% FROM COUNTY LIST 91 TREES 91 TREES (100%) SHRUBS - 50% FROM COUNTY LIST 1,043 SHRUBS 1,043 SHRUBS (100%) REQUIRED SPECIES TREES (27 TREES)5 SPECIES 6 SPECIES SP SABAL PALMETTO 10' - 14' C.T.BOOTS - VARY Y H 3 9 SABAL PALM STAGGERED HEIGHTS AS SHOWN ON PLANPA L M S AR ACER RUBRUM 12' HT.FIELD GROWN, B&B Y H 1 5 RED MAPLE 5' SPR.2.5" DBH, 5' CT. MIN. CE CONOCARPUS ERECTUS 12' HT.FIELD GROWN, B&B Y H 1 1 GREEN BUTTONWOOD 5' SPR.2.5" DBH, 5' CT. MIN. I C ILEX CASSINE 12' HT.FIELD GROWN, B&B Y M 2 2 DAHOON HOLLY 5' SPR.2.5" DBH, 5' CT. MIN. MG MAGNOLIA GRANDIFLORA 12' HT.FIELD GROWN B&B Y H 1 3 SOUTHERN MAGNOLIA 5' SPR.2.5" DBH. QV QUERCUS VIRGINIANA 12' HT.FIELD GROWN, B&B Y H 2 2 LIVE OAK 5' SPR.2.5" DBH, 5' CT. MIN. TD TAXIDIUM DISTICHUM 12' HT.FIELD GROWN, B&B Y H 8 BALD CYPRESS 5' SPR.2.5" DBH, 5' CT. MIN. Plant List SYM BOTANICAL NAME/HEIGHT/SPECIFICATION NATIVE DROUGHT TOTAL COMMON NAME SPREAD TOLERANT TR E E S SH R U B S CHR CHRYSOBALANUS ICACO 24" X 24"30" O.C.Y H 2 3 4 COCOPLUM FULL TO BASE CON CONOCARPUS ERECTUS 48" X 24"30" O.C.Y H 4 1 9 GREEN BUTTONWOOD FULL TO BASE MUH MUHLENBERGIA CAPILLARIS 24" X 18"30" O.C.Y H 1 5 PINK MUHLY GRASS FULL TO BASE RHA RHAPHIOLEPS INDICA 24" X 18"30" O.C.Y H 2 4 INDIAN HAWTHORN FULL TO BASE VIB VIBURUM SUSPENSUM 24" X 24"30" O.C.N H 3 5 1 SANDANKWA VIBURNUM FULL TO BASE DA T E : RE V : SC A L E : COPYRIGHT PATRICK D. CUNNINGHAM, LLC 519 Sapphire Drive Sarasota, Florida 34243 941.351.8915 ALL RIGHTS RESERVEDpcunningham.llc@gmail.com pl o t d a t e : fi l e n a m e : SH E E T NO R T H DL F P a c k i n g Ho u s e E x p a n s i o n St . L u c i e C o u n t y , F L Patrick D. Cunningham, LLC land planning landscape architecture 519 Sapphire Drive Sarasota, FL 34234 o:941.351.8915 PATRICK D. CUNNINGHAM FL REG. # LA: 0001669 pc u n n i n g h a m . L L C @ g m a i l . c o m SE A L 05 . 2 0 . 2 0 2 2 La n d s c a p e P l a n General Notes 01 . 0 4 . 2 0 2 3 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 50 100 50 0 05 . 0 3 . 2 0 2 3 Page 77 of 428 OOOOOOOO O O O O O O O O O O O O O O O O SH E E T L 2 SH E E T L 3 91 1105 90 104 1088 1087 1089 1091 1092 1093 1094 1095 1096 1097 1148 1150 1151 1149 1098 11001099 110111021103 1107 1106 1111 1153 1152 PROPOSED BUILDING EXPANSION 34,330 SF F.F.E.= 27.0 EXISTING BUILDING 50,904 SF F.F.E.= 23.3 UNDERGROUND UTILITIES OVERHEAD UTILITIES OVERHEAD UTILITIES 15' SAFE SIGHT TRIANGLE 15' SAFE SIGHT TRIANGLE 15' SAFE SIGHT TRIANGLE30' SAFE SIGHT TRIANGLE SIGN 92 93 94 95 96 108 107 1104 1142 1143 1144 1145 1112 113114 112 111110109 SH E E T L 5 SH E E T L 6 105 106 SHE E T L 2 SH E E T L 3 NORTH GRAVES ROAD OR A N G E A V E N U E CO U N T R Y R O A D N O . 6 8 SHE E T L 5 SHE E T L 6 LIM I T S O F W O R K (AP P R O X . ) L-2 KEY L-2 L-3 DA T E : RE V : SC A L E : COPYRIGHT PATRICK D. CUNNINGHAM, LLC 519 Sapphire Drive Sarasota, Florida 34243 941.351.8915 ALL RIGHTS RESERVEDpcunningham.llc@gmail.com pl o t d a t e : fi l e n a m e : SH E E T NO R T H DL F P a c k i n g Ho u s e E x p a n s i o n St . L u c i e C o u n t y , F L Patrick D. Cunningham, LLC land planning landscape architecture 519 Sapphire Drive Sarasota, FL 34234 o:941.351.8915 PATRICK D. CUNNINGHAM FL REG. # LA: 0001669 pc u n n i n g h a m . L L C @ g m a i l . c o m SE A L La n d s c a p e P l a n (s o u t h ) 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 30 60 30 0 1" = 3 0 ' - 0 " 0 30 60 05 . 2 0 . 2 0 2 2 01 . 0 4 . 2 0 2 3 05 . 0 3 . 2 0 2 3 Page 78 of 428 OOOOOOOO SH E E T L 2 SH E E T L 3 WASHWATER REUSE POND 0.31 AC @ CONTROL ELEV. = 17.8 NAVD PROPOSED DRY RETENTION POND 1.11 AC CITRUS CRATE DROP-OFF & EMPTY BOX STORAGE GROVE MAINTENANCE AREA SPRAY FIELD / TREE NURSERY (TO BE UNDISTURBED) OVERHEAD UTILITIES OVERHEAD UTILITIES 15' SAFE SIGHT TRIANGLE 15' SAFE SIGHT TRIANGLE 15' SAFE SIGHT TRIANGLE 15' SAFE SIGHT TRIANGLE 1142 1143 1144 1145 1024 1025 1039 1023 1032 1022 1021 98 99 870 871 872873874 100 101102 103 12 15 1314 23 22 16 21 34 3536 37 20 19 18 17 42 43 41 46 38 39 40 44 45 61 49 47 57 58 72 71 70 59 60 62 6667 6869 65 64 77 78 79 80 81 82 11 86 2 1 85 8384 8 7 9 10 6 63 1074 1076 1075 10771078 1073 1054 1055 1056 1079 1043 1072 1080 1050 1052 1051 1053 1049 1046 1048 1047 1045 1044 1042 1057 106810701071 1003 1006 1016 10151017 1019 1033 1020 1036 1031 10281038 1037 1082 1083 1061 1084 990 1065 991 984 939 935 912 920 893 867 868869 886 887 888884 883 882881 896 895 894 905 892 891890 889 904 919 923 956 953 952 950 949 948 947 932 918 917915 933 914 911 910 906908 909 907 934 936 937 985 986 989987 988 983 940941945946942 944 943 982 981980 979 993 1086 978977 976 996 1067 992 1035 1066 10631062 1060 1064 1035 1034 1027 1026 885 994 1030 1029 938 SH E E T L 5 SH E E T L 6 LESS 246.3' UNDISTURBED AREA LESS 281.8' UNDISTURBED AREA LI M I T S O F W O R K (A P P R O X . ) SH E E T L 2 SH E E T L 3 NORTH GRAVES ROAD ORA N G E A V E N U E COU N T R Y R O A D N O . 6 8 SHE E T L 5 SHE E T L 6 LIM I T S O F W O R K (AP P R O X . ) L-3 L-2 L-3 DA T E : RE V : SC A L E : COPYRIGHT PATRICK D. CUNNINGHAM, LLC 519 Sapphire Drive Sarasota, Florida 34243 941.351.8915 ALL RIGHTS RESERVEDpcunningham.llc@gmail.com pl o t d a t e : fi l e n a m e : SH E E T NO R T H DL F P a c k i n g Ho u s e E x p a n s i o n St . L u c i e C o u n t y , F L Patrick D. Cunningham, LLC land planning landscape architecture 519 Sapphire Drive Sarasota, FL 34234 o:941.351.8915 PATRICK D. CUNNINGHAM FL REG. # LA: 0001669 pc u n n i n g h a m . L L C @ g m a i l . c o m SE A L La n d s c a p e P l a n (n o r t h ) 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 30 60 30 0 1" = 3 0 ' - 0 " 0 30 60 05 . 2 0 . 2 0 2 2 01 . 0 4 . 2 0 2 3 05 . 0 3 . 2 0 2 3 Page 79 of 428 OOOO OOOO O O O O O O O O EXISTING ASPHALT TO BE MILLED AND RESURFACED 91 1105 90 104 1088 1087 1089 1091 1092 1093 1094 1095 1096 1097 1148 1150 1151 1149 1098 11001099 110111021103 1107 1106 1111 1153 1152 PROPOSED BUILDING EXPANSION 34,330 SF F.F.E.= 27.0 EXISTING BUILDING 50,904 SF F.F.E.= 23.3 NORTH GRAVES ROAD OR A N G E A V E N U E CO U N T R Y R O A D N O . 6 8 92 93 94 95 96 108 107 1104 1142 1143 1144 1145 1024 1025 1039 1023 1032 1022 1021 98 99 870 871 872873874 100 101102 103 12 15 1314 23 22 16 21 34 3536 37 20 19 18 17 42 43 41 46 38 39 40 44 45 61 49 47 57 58 72 71 70 59 60 62 6667 6869 65 64 77 78 79 80 81 82 11 86 2 1 85 8384 8 7 9 10 6 63 1074 1076 1075 10771078 1073 1054 1055 1056 1079 1043 1072 1080 1050 1052 1051 1053 1049 1046 1048 1047 1045 1044 1042 1057 106810701071 1003 1006 1016 10151017 1019 1033 1020 1036 1031 10281038 1037 1082 1083 1061 1084 990 1065 991 984 939 935 912 920 893 867 868869 886 887 888884 883 882881 896 895 894 905 892 891890 889 904 919 923 956 953 952 950 949 948 947 932 918 917915 933 914 911 910 906908 909 907 934 936 937 985 986 989987988 983 940941945946942944 943 982 981980 979 993 1086 978977 976 996 1067 992 1035 1066 10631062 1060 1064 1035 1034 1027 1026 885 994 1030 1029 1112 113114 112 111110109 938 SH E E T L 5 SH E E T L 6 105 106 LI M I T S O F W O R K (A P P R O X . ) SHE E T L 2 SH E E T L 3 91 PROPOSEDBUILDING EXPANSION34,330 SFF.F.E.= 27.0 EXISTING BUILDING50,904 SFF.F.E.= 23.3 NORTH GRAVES ROAD OR A N G E A V E N U E CO U N T R Y R O A D N O . 6 8 92 98 99 100101102103 12151314 42 43 11 1112 938 SHE E T L 5 SHE E T L 6 LIM I T S O F W O R K (AP P R O X . ) L-4 Key KEY L-5 DA T E : RE V : SC A L E : COPYRIGHT PATRICK D. CUNNINGHAM, LLC 519 Sapphire Drive Sarasota, Florida 34243 941.351.8915 ALL RIGHTS RESERVEDpcunningham.llc@gmail.com pl o t d a t e : fi l e n a m e : SH E E T NO R T H DL F P a c k i n g Ho u s e E x p a n s i o n St . L u c i e C o u n t y , F L Patrick D. Cunningham, LLC land planning landscape architecture 519 Sapphire Drive Sarasota, FL 34234 o:941.351.8915 PATRICK D. CUNNINGHAM FL REG. # LA: 0001669 pc u n n i n g h a m . L L C @ g m a i l . c o m SE A L Tr e e I n v e n t o r y P l a n (o v e r a l l ) 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 50 100 50 0 1110 EXISTING UNHEALTHY TREES AND PALMS THAT ARE CONSIDERED CULLS, REQUIRING REMOVAL. EXISTING TREES THAT ARE NOT 'SPECIMEN', THEREFORE NOT REQUIRING MITIGATION IF REMOVED. EXISTING 'SPECIMEN' TREES THAT REQUIRE MITIGATION WHEN REMOVED. EXISTING 'PROTECTED' PALMS THAT REQUIRE MITIGATION WHEN REMOVED. EXISTING TREES AND PALMS SAVED AND USED FOR TREE CREDITS TOWARDS REQUIRED LANDSCAPING. TO BE REMOVED TO BE REMOVED TO BE MITIGATED TO BE MITIGATED TO REMAIN L-6 1" = 5 0 ' - 0 " 0 50 10 0 05 . 2 0 . 2 0 2 2 01 . 0 4 . 2 0 2 3 05 . 0 3 . 2 0 2 3 Page 80 of 428 OOOOOOOO O O O O O O O O O O O O O O O O SH E E T L 2 SH E E T L 3 91 1105 90 104 1088 1087 1089 1091 1092 1093 1094 1095 1096 1097 1148 1150 1151 1149 1098 11001099 110111021103 1107 1106 1111 1153 1152 PROPOSED BUILDING EXPANSION 34,330 SF F.F.E.= 27.0 EXISTING BUILDING 50,904 SF F.F.E.= 23.3 NORTH GRAVES ROAD 92 93 94 95 96 108 107 1104 1142 1143 1144 1112 113114 112 111110109 SH E E T L 5 SH E E T L 6 105 106 SH E E T L 2 SH E E T L 3 NORTH GRAVES ROAD ORA N G E A V E N U E CO U N T R Y R O A D N O . 6 8 SHE E T L 5 SHE E T L 6 LIM I T S O F W O R K (AP P R O X . ) L-5 General Notes Key KEY L-5 DA T E : RE V : SC A L E : COPYRIGHT PATRICK D. CUNNINGHAM, LLC 519 Sapphire Drive Sarasota, Florida 34243 941.351.8915 ALL RIGHTS RESERVEDpcunningham.llc@gmail.com pl o t d a t e : fi l e n a m e : SH E E T NO R T H DL F P a c k i n g Ho u s e E x p a n s i o n St . L u c i e C o u n t y , F L Patrick D. Cunningham, LLC land planning landscape architecture 519 Sapphire Drive Sarasota, FL 34234 o:941.351.8915 PATRICK D. CUNNINGHAM FL REG. # LA: 0001669 pc u n n i n g h a m . L L C @ g m a i l . c o m SE A L Tr e e I n v e n t o r y P l a n (s o u t h ) 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 30 60 30 0 1110 EXISTING UNHEALTHY TREES AND PALMS THAT ARE CONSIDERED CULLS, REQUIRING REMOVAL. EXISTING TREES THAT ARE NOT 'SPECIMEN', THEREFORE NOT REQUIRING MITIGATION IF REMOVED. EXISTING 'SPECIMEN' TREES THAT REQUIRE MITIGATION WHEN REMOVED. EXISTING 'PROTECTED' PALMS THAT REQUIRE MITIGATION WHEN REMOVED. EXISTING TREES AND PALMS SAVED AND USED FOR TREE CREDITS TOWARDS REQUIRED LANDSCAPING. TO BE REMOVED TO BE REMOVED TO BE MITIGATED TO BE MITIGATED TO REMAIN L-6 1" = 3 0 ' - 0 " 0 30 60 05 . 2 0 . 2 0 2 2 01 . 0 4 . 2 0 2 3 05 . 0 3 . 2 0 2 3 Page 81 of 428 OOOOOOOO 1143 1144 1145 1024 1025 1039 1023 1032 1022 1021 98 99 870 871 872873 874 100 101102 103 12 15 1314 23 22 16 21 34 3536 37 20 19 18 17 42 43 41 46 38 39 40 44 45 61 49 47 57 58 72 71 70 59 60 62 6667 6869 65 64 77 78 79 80 81 82 11 86 2 1 85 8384 8 7 9 10 6 63 1074 1076 1075 10771078 1073 1054 1055 1056 1079 1043 1072 1080 1050 1052 1051 1053 1049 1046 1048 1047 1045 1044 1042 1057 106810701071 1003 1006 1016 10151017 1019 1033 1020 1036 1031 10281038 1037 1082 1083 1061 1084 990 1065 991 984 939 935 912 920 893 867 868869 886 887 888884 883 882881 896 895 894 905 892 891890 889 904 919 923 956 953 952 950 949 948 947 932 918 917915 933 914 911 910 906908 909 907 934 936 937 985 986 989987988 983 940941945946942 944 943 982 981980 979 993 1086 978977 976 996 1067 992 1035 1066 10631062 1060 1064 1035 1034 1027 1026 885 994 1030 1029 938 SH E E T L 5 SH E E T L 6 LI M I T S O F W O R K (A P P R O X . ) SH E E T L 2 SH E E T L 3 PROPOSEDBUILDING EXPANSION34,330 SFF.F.E.= 27.0 EXISTING BUILDING50,904 SFF.F.E.= 23.3 NORTH GRAVES ROAD ORA N G E A V E N U E CO U N T R Y R O A D N O . 6 8 SHE E T L 5 SHE E T L 6 LIM I T S O F W O R K (AP P R O X . ) L-6 General Notes Key KEY L-6 DA T E : RE V : SC A L E : COPYRIGHT PATRICK D. CUNNINGHAM, LLC 519 Sapphire Drive Sarasota, Florida 34243 941.351.8915 ALL RIGHTS RESERVEDpcunningham.llc@gmail.com pl o t d a t e : fi l e n a m e : SH E E T NO R T H DL F P a c k i n g Ho u s e E x p a n s i o n St . L u c i e C o u n t y , F L Patrick D. Cunningham, LLC land planning landscape architecture 519 Sapphire Drive Sarasota, FL 34234 o:941.351.8915 PATRICK D. CUNNINGHAM FL REG. # LA: 0001669 pc u n n i n g h a m . L L C @ g m a i l . c o m SE A L Tr e e I n v e n t o r y P l a n (n o r t h ) 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 30 60 30 01110 EXISTING UNHEALTHY TREES AND PALMS THAT ARE CONSIDERED CULLS, REQUIRING REMOVAL. EXISTING TREES THAT ARE NOT 'SPECIMEN', THEREFORE NOT REQUIRING MITIGATION IF REMOVED. EXISTING 'SPECIMEN' TREES THAT REQUIRE MITIGATION WHEN REMOVED. EXISTING 'PROTECTED' PALMS THAT REQUIRE MITIGATION WHEN REMOVED. EXISTING TREES AND PALMS SAVED AND USED FOR TREE CREDITS TOWARDS REQUIRED LANDSCAPING. TO BE REMOVED TO BE REMOVED TO BE MITIGATED TO BE MITIGATED TO REMAIN 1" = 3 0 ' - 0 " 0 30 60 05 . 2 0 . 2 0 2 2 01 . 0 4 . 2 0 2 3 05 . 0 3 . 2 0 2 3 Page 82 of 428 L-7 General Notes Key 1110 EXISTING UNHEALTHY TREES AND PALMS THAT ARE CONSIDERED CULLS, REQUIRING REMOVAL. EXISTING TREES THAT ARE NOT 'SPECIMEN', THEREFORE NOT REQUIRING MITIGATION IF REMOVED. EXISTING 'SPECIMEN' TREES THAT REQUIRE MITIGATION WHEN REMOVED. EXISTING 'PROTECTED' PALMS THAT REQUIRE MITIGATION WHEN REMOVED. EXISTING TREES AND PALMS SAVED AND USED FOR TREE CREDITS TOWARDS REQUIRED LANDSCAPING. TO BE REMOVED TO BE REMOVED TO BE MITIGATED TO BE MITIGATED TO REMAIN TYPICAL TREE PROTECTION DETAIL DA T E : RE V : SC A L E : COPYRIGHT PATRICK D. CUNNINGHAM, LLC 519 Sapphire Drive Sarasota, Florida 34243 941.351.8915 ALL RIGHTS RESERVEDpcunningham.llc@gmail.com pl o t d a t e : fi l e n a m e : SH E E T NO R T H DL F P a c k i n g Ho u s e E x p a n s i o n St . L u c i e C o u n t y , F L Patrick D. Cunningham, LLC land planning landscape architecture 519 Sapphire Drive Sarasota, FL 34234 o:941.351.8915 PATRICK D. CUNNINGHAM FL REG. # LA: 0001669 pc u n n i n g h a m . L L C @ g m a i l . c o m SE A L Tr e e I n v e n t o r y Sc h e d u l e TREE#SPECIES SIZE "ACTIONSTATUS Existing Cabbage Palm List Sabal Palm CREDITS 1 NOTES Specimen Remain Remain Remain Remain Remain Remain Remain Remain Remain Remain 0 Specimen Specimen Specimen Specimen Specimen Specimen Remain Remain Remain Remain Remain Remain Remain Remain Remain Remain Specimen Specimen Specimen 0 0 0--" --" --" --" --" --" --" --" --" --" --" - 1 0 TREE#SPECIES SIZE"ACTIONSTATUS 870 871 872 873 874 875 876 877 888 889 890 891 892 893 894 895 896 897 898 899 900 901 Existing Tree Inventory List 867 868 869 Laurel Oak NOTES Remove Remain Remain Remain Remain Remain Remain Specimen Specimen Specimen Specimen Specimen Remain Remain Remain Remain Remain Remain Remain Remain Remain Remain Remain Remain Remain Remain Remain Remain 905 906 907 908 909 910 911 912 914 915 917 918 919 920 921 922 923 924 925 902 903 904 OUT OF SEQUENCE Specimen Remain Remain Remain Remain Remain Remain Remain Specimen Specimen Specimen Specimen Remain Remain Remain Remain Remain Remain Remain Remain Remain Mitigate Specimen Remain Remain 930 931 932 933 934 935 936 937 938 939 940 941 942 943 944 945 946 947 948 949 950 927 928 929 Specimen Remain Remain Remain Remain Specimen Specimen Specimen Specimen Specimen Remain Remain Remain Remain Remain Remain Remain Remain Remain Remain Remain Specimen Specimen Remain Remain 955 956 957 958 959 960 961 962 963 965 966 977 978 979 980 981 952 953 Specimen Remain Remain Remain Remain Specimen Specimen Specimen Remain Remain Remain Remain Remain Remain Remain Remain Remain Specimen TREE#SPECIES SIZE "ACTIONSTATUS 987 988 989 990 991 992 993 994 995 996 NOTES Specimen Remain Remain Remain Remain Remain Remain Remain Remain Remain Specimen Specimen Specimen Specimen Remain Remain Remain Remain Remain Remain Remain Specimen Specimen Specimen Remain Remain 1000 1001 1002 1003 1005 1006 1007 1008 1009 1010 1011 1012 1013 1014 1015 1016 1017 1018 1020 1021 1022 997 998 999 Specimen Remain Specimen Specimen Remain Remain Remain Remain Remain Remain Remain Specimen Remain Remain 1026 1027 1028 1029 1030 1031 1032 1033 1034 1035 1036 1037 1038 1039 1040 1041 1042 1043 1044 1045 1046 1047 1023 1024 1025 Specimen Remain Remain Remain Remain Remain Remain Remain Remain Remain Remain Specimen Specimen Specimen Specimen Specimen Specimen Specimen Remain Remain Remain Remain Remain Remain Remain Remain Remain Remain Remain Remain Specimen Specimen Specimen 1051 1052 1053 1054 1055 1056 1057 1058 1059 1060 1061 1062 1068 1070 1071 1072 1048 1049 1050 Specimen Remain Remain Remain Remain Remain Remain Remain Remain Specimen Specimen Specimen Specimen Specimen Remain Remain Remain Remain Remain Remain Remain Remain Remain Remain Remain Remain Remain Remain Remain Specimen Specimen Remain Remain TREE#SPECIES SIZE "ACTIONSTATUS 21" CREDITS(IN.) (EQ. #)NOTES Specimen Remain Remain Remain Remain Remain Remain Remain Remain Remain Specimen Specimen Specimen Specimen Specimen Remain Remain Remain Remain Remain Remain Remain Remain Remain Remain Remain Remain Remain Specimen Remain Remain Specimen Remain Remain Remain Remain Remain Remain Remain Remain Specimen Specimen Specimen Specimen Specimen Specimen Specimen Remain Remain Remain Remain Remain Remain Remain Remain Remain Remain Remain Remain Remain Specimen Specimen Specimen Off-site --" Remain Remain Remain Remain Remain Remain Remain Remain Remain Remain Specimen Specimen Specimen Specimen Specimen Specimen Remain Remain Remain Remain Remain Specimen Specimen Specimen 0 0 --" --" --" --" --" --" --" --" --" --" --" Remain--" --" Remain Remain Remain Remain Remain Remain Remain Remain Remain Remain Remain Remain Remain Remain Remain Remain--" --" --" --" --" --" --" --" --" --" --" --" --" TREE#SPECIES SIZE "ACTIONSTATUS Sabal Palm " --" " " " CREDITS + 1 Palm NOTES Remain Remain Remain Remain Remain Remain Remain Remain Specimen Remain Remain Remain Remain Remain Remain Remain Remain Remain Remain Remain Remain 0 0 --" --" --" " " --" --" --" --" --" --" Remain--" Remain 0--" " " 10 " " " " 0 Off-site Remain Remain Remain 0 Remain Remain Remain Remain Remain Remain Remain Remain Remain Pygmy Date 012" 0 0 0 0 0 0 62 64 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 63 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 Queen Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal PalmSabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal PalmSabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal PalmSabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal PalmSabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal PalmSabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal PalmSabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal PalmSabal Palm Sabal Palm Sabal Palm Sabal Palm Sabal Palm Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Mitigation Mitigation Mitigation Mitigation Mitigation Mitigation Mitigation Mitigation Mitigation Mitigation Mitigation Mitigation Mitigation Mitigation Mitigation Mitigation Mitigation Mitigation Mitigation Mitigation Mitigation Mitigation Mitigation Mitigation Mitigation Mitigation Mitigation Mitigation Mitigation Off-site Off-site Off-site Off-site Off-site Off-site Off-site Off-site Off-site Off-site Off-site Off-site 9 5 "5 "4 "13 16 15 -- -- -- -- -- -- -- --" --" "-- "-- "-- "-- "-- "-- "-- --" --" --" --" --" --" --" --" --" --" --" --" --" --" --" --" --" --" --" --" --" --" --" --" --" --" --" --" --" --" --" --" --" --" --" --" --" - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 Tree Mitigation Calculations MITIGATION/ QUANTITY CREDIT TO REMAIN TOTAL CABBAGE PALMS 64 PALMS TOTAL TREES 181 TREES CREDITS CABBAGE PALMS - REMAIN @ 1:1 64 PALMS 64 CREDITS TREES 2" - 6" DBH @ 1:1 16 TREES 16 CREDITS 7" - 12" DBH @ 2:1 43 TREES 86 CREDITS 13" - 18" DBH @ 3:1 59 TREES 177 CREDITS 19" - 24" DBH @ 4:1 23 TREES 92 CREDITS 25" - 30" DBH @ 5:1 25 TREES 125 CREDITS 31" OR MORE @ 8:1 15 TREES 120 CREDITS TOTAL TREE CREDITS 181 TREES 616 CREDITS 3,187 INCHES 6,374 INCHES TO BE REMOVED TOTAL UNHEALTHY / CULLED CABBAGE PALMS - 0 PALMS TOTAL UNHEALTHY / CULLED TREES - 1 TREE TOTAL NON-SPECIMEN TREES - 39 TREES MITIGATION PROPOSED (NON-SPECIMEN)NOT APPLICABLE TOTAL SPECIMEN TREES - 24 TREES - 420" DBH TOTAL CABBAGE PALMS - 29 PALMS MITIGATION TOTAL TREES TO BE REMOVED (DBH INCHES)- 24 TREES - 420" DBH TOTAL TREE MITIGATION REQUIRED 840" DBH 420" DBH @ 2 : 1 REPLACEMENT = PROPOSED MITIGATION + 0 TREES 0" DBH 6,374" DBH - 840" DBH = 5,534" DBH CREDIT TOTAL PALMS TO BE REMOVED - 29 PALMS TOTAL MITIGATION @ 1: 2 58 PALMS PROPOSED MITIGATION @ 1: 2 0 PALMS (64 PALMS CREDIT) - (58 PALMS REQ. MIT.) = 6 PALMS CREDIT MITIGATION/ QUANTITY CREDIT TOTAL TO REMAIN 64 PALMS 64 PALMS TO BE REMOVED - 29 PALMS - 58 PALMS (@ 1:2) SURPLUS 6 PALMS 926 878 879 880 881 882 883 884 885 886 887 967 968 969 970 971 1073 1074 1075 1076 1077 972 973 974 975 976 986 985 984 983 982 OUT OF SEQUENCE OUT OF SEQUENCE OUT OF SEQUENCE OUT OF SEQUENCE 1063 1064 1065 1066 1067 1078 1079 1080 1081 1082 1083 1084 1085 1086 1087 1088 1089 1091 1092 1093 1094 OUT OF SEQUENCE 1095 1096 1097 1098 1099 1100 1101 1102 1103 1104 1105 1106 1107 1111 1112 OUT OF SEQUENCE OUT OF SEQUENCE 1142 1143 1144 1145 1147 13" Remain Remain Remain Remain Remain 212" 12" Remain14" Remain6"- multi 1148 1149 1150 1151 1152 RemainRemain6"- multi1153 Mitigate Mitigate Mitigate Mitigate Mitigate Mitigate Mitigate Mitigate Mitigate Mitigate Mitigate Mitigate Mitigate Mitigate Mitigate Mitigate Mitigate Mitigate Mitigate Mitigate Mitigate Mitigate Mitigate Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak 1019 Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Live Oak Crape Myrtle Bottlebrush Specimen Specimen Specimen Specimen CREDITS(IN.) (EQ. #)CREDITS(IN.) (EQ. #) 26 " 24 " 24 " 28 " 12 " 12 " 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 1 1 1 3 2 3 1 1 Not on Survey Not on Survey Off-site Unhealthy/Cull 332Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Remain16" 42 4 Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak 16 " Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen OUT OF SEQUENCE Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen Specimen 332"" 16 "332"" 16 "332"" 16 "332"" 16"332 16"332 16"332 16"332 16"332 21""- 42 21""42 4 21""42 4 21""42 4 21"42 4 21"42 4" " " " " " " " " 6 "12 "1 6 "12 "1 6 "12 "1 6 "12 "1 6 "12 "1 6 " 6 "12 "1 6 " 6 "12 "1 6 "12 "1 6 "12 "1 6"12 "1 6"12 "1 6"12 "1 14 "28 "3 14 "- 28 " 14 "28 "3 14 "28 "3 14 "28 "3 14 "- 28 " 14 "28 "3 14 "28 "3 14 "28 "3 14"28 "3 12 "24 "2 12 "24 "2 12 " 12 "24 "2 12 "24 "2 12 "-24 " 12 "- 24 " 12 "24 "2 12 "24 "2 12 "24 "2 12"24 "2 12"24 "2 13 "26 "3 13 "26 "3 13 "26 "3 13 "26 "3 13 "- 26 " 13 "26 "3 13 "- 26 " 13 "- 26 " 13 "- 26 " 13 "- 26 " 13 "26 "3 13 "26 "3 13 "26 "3 13 "26 "3 13 "26 "3 13 "26 "3 13 "- 26 " 13 "- 26 " 13 "26 "3 13"26 "3 13"26 "3 13"26 "3 15 "30 "3 15 "30 "3 15 "- 30 " 15 "30 "3 15 "30 "3 15 "30 "3 15 "30 "3 15 "- 30 " 15 "30 "3 15 "30 "3 15"30 "3 11"22 "2 11"22 "2 11"--"-- 11" 11"22 "2 11"22 "2 11" 11" 11" 11"22 "2 11"22 "2 11"22 "2 11" 11" 11" 11" 11" 11" 11"22 "2 11"22 "2 8 "16 "2 8 " 8 " 8 " 8 "16 "2 8 "16 "2 8 " 8 "16 "2 8 "16 "2 8 "16 "2 8"16 "0 8" 7 "14 "2 7 " 7 "14 "2 7 "14 "2 7 "14 "2 7 " 7 "14 "2 7 " 7 "14 "2 7 "14 "2 7"14 "2 5 " 5 "10 "1 5 "10 "1 5 " 5 " 5"17 "34 "3 17 "34 "3 17 "34 "3 17 "34 "3 17 "34 "3 17 "34 "3 17 "34 "3 17"34 "3 9 "18 "2 9 " 9 "18 "2 9 "18 "2 9 " 9 " 9 "18 "2 9"18 "2 9 "18 "2 9 "18 "2 25 "50 "5 25 "50 "5 25 "50 "5 25 "50 "5 25"50 "5 25"50 "5 25"50 "5 10 "20 "2 10 " 10 " 10 "20 "2 10 "20 "2 10 " 10 " 10 " 10 " 10 " 10 " 19 "- 38 " 19 "38 "4 19 "38 "4 19 "38 "4 19"38 "4 24 "48 "4 24 "48 "4 24 "48 "4 18 "36 "3 18 "- 36 " 18 "36 "0 18 "36 "3 18 "- 36 " 18 "- 36 " 18 "36 "3 18 "- 36 " 18 "36 "3 18 "36 "3 18 "36 "3 18"36 "3 Laurel Oak Laurel Oak Laurel Oak Laurel Oak Laurel Oak 31"62 "8 31"62 "8 31"62 "8 25 "- 50 " 22 "44 "4 22 "44 "4 22 "44 "4 22 "44 "4 22 "44 "4 22"44 "4 20 "- 40 " 20"40 "4 20"40 "4 28 "- 56 " 28 "56 "5 28 "56 "5 28"56 "5 28"56 "5 23 "- 46 " 23 "46 "4 27 "54 "5 27 "54 "5 27 "54 "5 27 "54 "5 27 "54 "5 27"54 "5 27"54 "5 41"82 "8 38 "76 "8 38 "76 "8 83"166 "8 26 "52 "5 26"52 "5 48 "96 "8 48"96 "8 29 "58 "5 29 "58 "5 36 "72 "8 30 "60 "5 30 "60 "5 30"60 "5 42 "84 "8 39 "-78 " 39"78 "8 43 "86 "8 4 " 34"68 "8 21"42 4" 35"70 8" OUT OF SEQUENCE Remove --"-- Remove --"-- Remove --"-- Remove --"-- Remove --"-- Remove --"-- Remove --"-- Remove --"-- Remove --"-- Remove --"-- Remove --"-- Remove --"-- Remove --"-- Remove --"-- Remove --"-- Remove --"-- Remove --"-- Remove --"-- Remove --"-- Remove --"-- Remove --"-- Remove --"-- Remove --"-- Remove --"-- Remove --"-- Remove --"-- Remove --"-- Remove --"-- Remove --"-- Remove --"-- Remove --"-- Remove --"-- Remove --"-- Remove --"-- Remove --"-- Remove --"-- Remove --"-- MITIGATION/ QUANTITY CREDIT TOTAL TO REMAIN 181 TREES 3,187 INCHES 616 TREE CREDITS TO BE MITIGATED - 24 TREES - 840 INCHES (@ 2:1) SURPLUS 157 TREES 2,347 INCHES 616 TREE CREDITS -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- OUT OF SEQUENCE 113 114 Sabal Palm Sabal Palm 14 10 " " RemainSpecimen 1 RemainSpecimen 1 NO N E 0 0 0 05 . 2 0 . 2 0 2 2 01 . 0 4 . 2 0 2 3 05 . 0 3 . 2 0 2 3 NOTE: IF CROSS-REFERENCING, "NOT ON SURVEY" INDICATES THAT THE SPECIFIC TREES ARE CALLED OUT ON THE TREE INVENTORY PLAN WITHIN THE PLAN SET, BUT NOT ON BOUNDARY SURVEY PREPARED BY WILLIAM B. ZENTZ & ASSOC., DATED 12/24/2021. Off-site Off-site 1 Bldg. Perim. Bldg. Perim. Bldg. Perim. South Buffer South Buffer South Buffer South Buffer South Buffer VUA Interior VUA Interior VUA Interior VUA Interior VUA Interior VUA Interior VUA Interior VUA Interior West Buffer West Buffer West Buffer West Buffer West Buffer West Buffer West Buffer West Buffer West Buffer West Buffer West Buffer West Buffer West Buffer East Buffer East Buffer East Buffer East Buffer East Buffer East Buffer East Buffer East Buffer VUA Interior VUA Interior VUA Interior Pygmy Date Pygmy Date Queen Palm Queen Palm Crape Myrtle Bottlebrush Bottlebrush Bottlebrush Page 83 of 428 L-8 ° TYPICAL PALM PLANTING DETAIL TYPICAL TREE PLANTING DETAIL TYPICAL SHRUB/ GROUNDCOVER PLANTING DETAIL TYPICAL TREE GUYING DETAIL TYPICAL PLANT SPACING DETAIL CLEAR TRUNK WITHIN SIGHT TRIANGLE DETAIL TYPICAL IRREGULAR/MULTI-TRUNK TREE PLANTING DETAIL 24" DEEPROOT TREE ROOT BARRIERS PARKING SPACE/CURB PLANTING DA T E : RE V : SC A L E : COPYRIGHT PATRICK D. CUNNINGHAM, LLC 519 Sapphire Drive Sarasota, Florida 34243 941.351.8915 ALL RIGHTS RESERVEDpcunningham.llc@gmail.com pl o t d a t e : fi l e n a m e : SH E E T NO R T H DL F P a c k i n g Ho u s e E x p a n s i o n St . L u c i e C o u n t y , F L Patrick D. Cunningham, LLC land planning landscape architecture 519 Sapphire Drive Sarasota, FL 34234 o:941.351.8915 PATRICK D. CUNNINGHAM FL REG. # LA: 0001669 pc u n n i n g h a m . L L C @ g m a i l . c o m SE A L La n d s c a p e D e t a i l s NO N E 0 0 0 05 . 2 0 . 2 0 2 2 05 . 0 3 . 2 0 2 3 Page 84 of 428 L-9 LI t t o r a l Z o n e Pl a n t i n g & D e t a i l s AS S H O W N 0 0 0 05 . 2 0 . 2 0 2 2 05 . 0 3 . 2 0 2 3 DA T E : RE V : SC A L E : COPYRIGHT ALL RIGHTS RESERVED pl o t d a t e : fi l e n a m e : SH E E T NO R T H DL F P a c k i n g Ho u s e E x p a n s i o n St . L u c i e C o u n t y , F L PATRICK D. CUNNINGHAM FL REG. # LA: 0001669 SE A L CROSS-SECTION A CROSS-SECTION B LITTORAL PLANTING PLAN 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 20 100 20 0 Page 85 of 428 Page 86 of 428 Page 87 of 428 Page 88 of 428 Page 89 of 428 TR-39789673 ST. LUCIE COUNTY PLANNING & ZONING COMMISSION PUBLIC HEARING AGENDA Thursday, July 18, 2024 NOTICE OF PROPOSED AMENDMENT OF ZONING ATLAS AND PRELIMINARY DEVELOPMENT PLAN The St. Lucie County Planning & Zoning Commission is scheduled to review and make a recommendation to the Board of County Commissioners regarding the following proposed Resolution: RESOLUTION A RESOLUTION OF THE BOARD OF COUNTY COMMISSIONERS OF ST. LUCIE COUNTY AMENDING THE OFFICIAL ZONING ATLAS FROM THE AGRICULTURAL-5 (AG-5) ZONING DISTRICT TO THE PLANNED NON-RESIDENTIAL DEVELOPMENT (PNRD) ZONING DISTRICT AND APPROVING A PRELIMINARY DEVELOPMENT PLAN, MAINTAINING AN EXISTING CONDITIONAL USE PERMIT ON +/- 19.34 ACRES LOCATED WITHIN ST. LUCIE COUNTY, FLORIDA. APPLICANT: Doug Feek - DLF Packing LLC & MBV Engineering PROPERTY OWNERS: DLF Packing LLC FILE NUMBER: PD-2402-000035 PARCEL IDs: 221224200010008 PURPOSE: The Applicant has petitioned to amend the St. Lucie County Zoning Atlas to change the zoning district on +/-19.34 acres from AG-5 (Agricultural - 5) to Planned Non-residential Development (PNRD) and for approval of a Preliminary Development Plan, while merging the active DLP (DLF) Citrus Conditional Use Permit. The applicant is working to complete the approved 35,000 sq. ft. expansion to accommodate new freezers, relocation of the loading docks, and expansion of the internal support areas, for the existing 51,000 sq. ft. citrus packing facility, formerly known as Sun Brite Citrus. The petition will also provide Lot Coverage relief from the AG-5 District’s 10% standard. The Planning and Zoning Commission’s PUBLIC HEARING on this item will be held in the Commission Chambers, Roger Poitras Annex, 3rd Floor, St. Lucie County Administration Building, 2300 Virginia Ave., Fort Pierce, FL on Thursday, July 18, 2024, beginning at 6:00 pm or as soon thereafter as possible. All interested persons will be given an opportunity to be heard. Written comments received in advance of the public hearing will also be considered. Written comments to the Planning and Zoning Commission should be received by the Planning and Development Services Department - Planning Division at least three (3) days prior to the scheduled hearing. The petition files are available for review at the Planning and Development Services Dept.– Planning Offices located at 2300 Virginia Ave., Fort Pierce, FL, during regular business hours. Please call (772) 462-2822 or TDD (772) 462-1428 if you have any questions or require additional information about this petition. The St. Lucie County Planning and Zoning Commission has the power to review and recommend approval or disapproval, to the Board of County Commissioners, of any applications within their area of responsibility. The proceedings of the Planning and Zoning Commission are electronically recorded. PURSUANT TO SECTION 286.0105, FLORIDA STATUTES, if a person decides to appeal any decision made by the Planning and Zoning Commission with respect to any matter considered at a meeting or hearing, he or she will need a record of the proceedings. For such purpose, he or she may need to ensure that a verbatim record of the proceedings is made, which record includes the testimony and evidence upon which the appeal is to be based. Upon the request of any party to the proceeding, individuals testifying during a hearing will be sworn in. Any party to the proceeding will be granted an opportunity to cross-examine any individual testifying during a hearing upon request. If it becomes necessary, a public hearing may be continued to a date certain. Anyone with a disability requiring accommodation to attend this meeting should contact the St. Lucie County Risk Manager at least forty-eight (48) hours prior to the meeting at (772) 462-1546 or T.D.D. (772) 462-1428. PLANNING AND ZONING COMMISSION ST. LUCIE COUNTY, FLORIDA ED LOUNDS, CHAIRMAN PUBLISH DATE: Wednesday, July 3, 2024 Page 90 of 428 Page 91 of 428 O0-I IA 3Q;0F — Ap m o Cr,ZAo0 0Wcn1t1 Resolution 2022-144 N5P"vo09 File No. CUMj-4202126009 o"N m mN coo 0Nr A RESOLUTION GRANTING A MAJOR ADJUSTMENT TO A CONDITIONAL W s USE PERMIT FOR DLF CITRUS (FKA SUN BRITE CITRUS) TO EXPAND 0 THE CITRUS PROCESSING AND PACKING FACILITY WITHIN THE AG-5 0 m AGRICULTURAL - 5) ZONING DISTRICT LOCATED AT 150 GRAVES M A ROAD IN ST. LUCIE COUNTY, FLORIDA. o C 0 0 WHEREAS, the Board of County Commissioners of St. Lucie County, Florida, based on 1 testimony and evidence, including but not limited to findings in the staff report, has made following determinations: 1.DLF Packing, LLC, presented a petition for a Major Adjustment to the existing Conditio Use Permit to expand an existing 51,000 sq. ft. citrus packing facility by no more th- 33,245 sq. ft., formerly known as Sun Brite Citrus, to accommodate new freezers, relocation of the loading docks, and expansion of the internal support areas for their facility on a +/- 19.3-acre parcel located at 150 Graves Road, at the northeast corner of Graves Road and Orange Avenue, within the AG-5 (Agricultural-5) Zoning District legally described in Paragraph C and depicted on the attached map as Exhibit "A". The applicant has filed a concurrent Adjustment to the approved site plan, which shall require final action by the Planning and Development Services Director. 2.On July 28, 1992, the Board approved Resolution 92-103, granting a Conditional Use Permit for Sun Brite Citrus to develop a 45,100 sq. ft. warehouse and 3,750 sq. ft. office for a Citrus Packing operation, after holding a public hearing on the petition, after publishing a notice at least 10 days prior to the hearing and notifying by mail all owners of property within 500 feet of the subject property, at which all interested persons were given an opportunity to be heard. 3.On June 16, 1994, the Community Development Director granted approved a Minor Adjustment to the Major Site Plan to relocate the handicapped parking spaces and to amend the dimensions of the cannery. 4.On July 5, 2022, the Board of County Commissioners approved a Transportation Impact Study Waiver for the DLP (AKA DLF) Citrus Site Plan & Conditional Use Adjustments pursuant to St. Lucie County Land Development Code (LDC) Section 11.02.09(A)(4)(a). 5.The Development Review Committee has reviewed the proposed Major Adjustment and found it to be in substantial conformity with the existing Conditional Use. 6.St. Lucie County Planning and Development Services staff has performed the required land use analysis for this application.e 7.On August 16, 2022, this Board held a public hearing on the petition, after publishing a notice of such hearing, causing a sign to posted on the premises and notifying by mail all owners of property within 500 feet of the subject property. 8.The Major Adjustment to an existing Conditional Use Permit, with the conditions therein, is consistent with the goals, objectives, and policies of the St. Lucie County Comprehensive Plan and has satisfied the requirements of Section 11.07.03 of the St. Lucie County Land Development Code. File No.: CUMj-4202126009 Resolution No. 2022-144 Page 1 Page 92 of 428 9. The project, with restated and amended conditions therein, will not have an undue adverse effect on adjacent property, the character of the neighborhood, traffic conditions, parking, utilities, or other matters affecting the public health, safety, and general welfare. 10. The proposed project will be serviced by adequate public facilities and services. 11. The Certificate of Capacity as required under Chapter V, St. Lucie County Land Development Code, shall be required for authorization of the associated Site Plan Adjustment. NOW, THEREFORE, BE IT RESOLVED by the Board of County Commissioners of St. Lucie County, Florida: A. The foregoing findings are hereby approved and adopted by the Board of County Commissioners of St. Lucie County, Florida. B. Pursuant to Sections 11.07.03 & 11.07.04, Conditional Uses, and Sections 3.01.03(C)(7) e. of the Land development Code, the Conditional Use Permit for DLF Citrus (FKA Sun Brite Citrus), approved by Resolution 92-103, on for the property described in Paragraph C is hereby Adjusted as generally shown on the drawings for the project prepared by MBV Engineering dated February 2022, subject to the following conditions: C. The property on which this Major Adjustment to a Conditional Use Permit is being granted is described as follows: Prior to authorizing the associated Site Plan Adjustment, the applicant and/or representatives shall update the Site Plan to comply with the maximum 10% Lot Coverage permitted in the AG-5 Zoning District. 2. Prior to authorizing the associated Site Plan Adjustment, the applicant and/or representatives shall update the proposed Landscape Plan in accordance with the Land Development Code as highlighted in the July 25, 2022 Environmental Resources Department Comment Letter as summarized in this letter. 3. All project access points to Graves Road shall connect a section of Graves Road, paved to County Public Works Specifications. The applicant may be required to permit and extend the paved section of Graves Road to serve the northern access point proposed to serve the project, providing an access radius of return at a minimum of 35ft. 4. The proposed gates shall be open during hours of operation, unless the restricted gate access standards of LDC Section 7.10.15 are met by the Site Plan Adjustment. 5. Prior to issuance of a Certificate of Occupancy all Category I listed invasive plant species shall be eradicated from the site. 6. Prior to issuance of a Vegetation Removal Permit or Exemption, listed species surveys including but not limited to gopher tortoise surveys shall be updated as required per state and/or federal survey protocol. Should any listed species be found as a result of these updated surveys, appropriate permits from state and federal agencies shall be required. File No.: CUMj-4202126009 Resolution No. 2022-144 Page 2 Page 93 of 428 Legal Description: The West 1/2 of the Southeast 1/4 of the Northwest 1/4 of Section 12, Township 35 South, Range 38 East, St. Lucie County, Florida, less and excepting 25 foot right of way for Graves Road as recorded in Deed Book 77, Page 27B, also less and except the East 10 feet of the West 35 feet of the West 1/2 of the Southeast 1/4 of the Northwest 1/4 as recorded in O. R. Book 869, Page 8, of the Public Records of St. Lucie County, Florida. Parcel ID#: 2213-242-0001-000-8 D. The approvals and authorizations granted by this Resolution are for the purpose of expanding an existing citrus packing and distribution facility within St. Lucie County, and are not assigned to any other party or institution. Should the petitioners choose or decide to assign this operation to another entity or individual, a minor adjustment to the Conditional Use Permit shall be required. E. The approvals and authorizations granted by this Resolution are for the purpose of obtaining a Site Plan Adjustment, Building Permit and/or Zoning Compliance from St. Lucie County, and are not assigned to any other party or institution. Should the applicant choose or decide to assign this business to another entity or individual, an adjustment to this Conditional Use Permit shall be required. F. Pursuant to Section 11.07.05(I) of the St. Lucie County Land Development Code, a Conditional Use Permit, and Adjustments thereof, shall be valid for the purposes of securing a Building Permit or Certificate of Zoning Compliance for twelve (12) months from the date of this approval, unless a Building Permit or Certificate of Zoning Compliance is secured within twelve (12) months, and construction subsequently undertaken pursuant to such Building Permit, the Conditional Use Permit shall automatically expire unless the permit is extended upon application to the Board of County Commissioners. G. The developer is advised as part of this Conditional Use Permit Adjustment, including any successors in interest, the developer shall obtain all applicable development permits and construction authorizations from the appropriate state and federal and local regulatory agencies including, but not limited to, the United States Army Corps of Engineers, the Florida Department of Environmental Protection, and South Florida Water Management District, and the St. Lucie County Environmental Resources, Public Works and Building Departments prior to the commencement of any development activities on the property described in Paragraph C". Issuance of this permit by the County does not in any way create any rights on the part of the developer to obtain a permit from a State or Federal agency and does not create any liability on the part of the County for issuance of this permit if the developer fails to obtain requisite approvals or fulfill the obligations imposed by a state or federal agency or undertake actions that may result in a violation of State or Federal law. H. The St. Lucie County Planning and Development Services Director is hereby authorized and directed to cause the notation of this resolution to be made on the Official Zoning Map of St. Lucie County, Florida, and to make notation of reference to the date of adoption of this resolution. I. This Resolution shall become effective upon the date indicated below. An appeal of the Board of County Commissioners' action may be processed within thirty (30) days in accordance with Section 11.11.02.F, of the St. Lucie County Land Development Code. File No.: CUMj-4202126009 Resolution No. 2022-144 Page 3 Page 94 of 428 J. This Resolution shall be recorded in the Public Records of St. Lucie County. K. Adoption After motion and second, the vote on this resolution was as follows: Sean Mitchell, Chair AYE Frannie Hutchinson, Vice -Chair AYE Chris Dzadovsky, Commissioner AYE Linda Bartz, Commissioner AYE Cathy Townsend, Commissioner AYE PASSED AND DULY ADOPTED this 16th day of August, 2022. BOARD OF COUNTY COMMISSIONERS ST. LUCIE COUNTY, FLOIRDA BY 6Z. ps ATTEST: DEPUTY CLERK J 41 COMA' Z co c vN7'Y FLO t Chair APPROVED AS TO FORM AND CORRECTNESS: COUNTY ATTO File No.: CUMj-4202126009 Resolution No. 2022-144 Page 4 Page 95 of 428 N A Orange Avenue Exhibit "A" Location Map) Subject property r e U cU c o U a C N 2 File No.: CUMj-4202126009 Resolution No. 2022-144 Page 5 Page 96 of 428 PDS Order 2023-037 File No. SPMj-4202126010 AN ORDER GRANTING A MAJOR ADJUSTMENT TO A MINOR SITE PLAN FOR DLF CITRUS (FKA SUN BRITE CITRUS) TO EXPAND THE CITRUS PROCESSING AND PACKING FACILITY WITHIN THE AG-5 AGRICULTURAL - 5) ZONING DISTRICT LOCATED AT 150 GRAVES ROAD IN ST. LUCIE COUNTY, FLORIDA. WHEREAS, St. Lucie County Planning and Development Services Director, has reviewed the application for a Major Adjustment to a Minor Site Plan, filed by MBV Engineering on behalf of DLF Citrus, evaluated the comments of the St. Lucie County Development Review Committee on this application and has made the following determinations: DLF Packing, LLC, presented a petition for a Major Adjustment to a Site Plan to expand an existing 51,000 sq. ft. citrus packing facility by up to 33,245 sq. ft., formerly known as Sun Brite Citrus, to accommodate new freezers, relocation of the loading docks, and expansion of the internal support areas for their facility on a +/- 19.3-acre parcel located at 150 Graves Road, at the northeast corner of Graves Road and Orange Avenue, within the AG-5 (Agricultural-5) Zoning District legally described in Part "B" and depicted on the attached map as Exhibit "A". 2. On July 28, 1992, the Board approved Resolution 92-103, granting a Conditional Use Permit for Sun Brite Citrus to develop a 45,100 sq. ft. warehouse and 3,750 sq. ft. office for a Citrus Packing operation, after holding a public hearing on the petition, after publishing a notice at least 10 days prior to the hearing and notifying by mail all owners of property within 500 feet of the subject property, at which all interested persons were given an opportunity to be heard. 3. On June 16, 1994, the Community Development Director granted approved a Minor Adjustment to the Major Site Plan to relocate the handicapped parking spaces and to amend the dimensions of the cannery. 4. On July 5, 2022, the Board of County Commissioners approved a Transportation Impact Study Waiver for the DLP (AKA DLF) Citrus Site Plan & Conditional Use Adjustments pursuant to St. Lucie County Land Development Code (LDC) Section 11.02.09(A)(4)(a). 5. On August 16, 2022, the Board of County Commissioners approved Resolution 2022-144 granting a Major Adjustment to the existing Conditional Use Permit to expand an existing 51,000 sq. ft. citrus packing facility by no more than 33,245 sq. ft., formerly known as Sun Brite Citrus, to accommodate new freezers, relocation of the loading docks, and expansion of the internal support areas. 6. The Development Review Committee has reviewed the proposed Major Adjustment and found it to be consistent with the associated Conditional Use Permit. 7. St. Lucie County Planning and Development Services staff has performed the required land use analysis for this application. 8. The project, with conditions herein, will not have an undue adverse effect on adjacent property, the character of the neighborhood, traffic conditions, parking, utilities, or other matters affecting the public health, safety, and general welfare. 9. The proposed project will be serviced by adequate public facilities and services. MICHELLE R. MILLER, File No.: SPMj-4202126010 SAINT LUCIE COUNTY CLERK OF THE CIRCUIT COURT ler No. 2023-037 Page 1 FILE # 5210873 06/28/2023 12-18:53 PM OR BOOK 5010 PAGE 120 - 126 Doc Type: ORD RECORDING: $61.00 Page 97 of 428 10. The Certificate of Capacity as required under Chapter V, St. Lucie County Land Development Code, is authorized as contained herein as Exhibit "C". NOW, THEREFORE, BE IT ORDERED by the Planning & Development Services Director of St. Lucie County, Florida: A. Pursuant to Section 11.02.03 of the St. Lucie County Land Development Code, the Final Minor) Site Plan to be known as DLF Citrus (FKA Sun Brite Citrus), for the property described in Paragraph C is hereby adjusted as generally shown on the drawings for the project prepared by MBV Engineering dated May 5, 2023, subject to the following conditions: 1. Prior to issuance of a Certificate of Occupancy, the as -built survey shall demonstrate the building lot coverage does not exceed the maximum 10% as permitted in the AG- 5 Zoning District (Table 7-10). 2. All project access points to Graves Road shall connect to a paved section of Graves Road, designed to County Public Works Specifications. 3. The proposed gates shall be open during hours of operation, unless the restricted gate access standards of LDC Section 7.10.15 are met by a future Site Plan Adjustment. 4. Prior to issuance of a Certificate of Occupancy, all Category I listed invasive plant species shall be eradicated from the site. 5. Prior to issuance of a Vegetation Removal Permit or Exemption, listed species surveys including but not limited to gopher tortoise surveys shall be updated as required per state and/or federal survey protocol. Should any listed species be found as a result of these updated surveys, appropriate permits from state and federal agencies shall be required. 6. Within 90 days of approval, the Professional Surveyor and Mapper shall file the new certified section corner records. It is required by Chapter 177, Part III Restoration of Corners (ss.177.501-177.510). Please file a new certified section corner record for each section corner used for this survey. Florida Chapter 177, Part II. All corners fall in canals shall be set on offset and witness corners shall be set and new certified corner records shall be filed. 7. Prior to commencement of development, including, but not limited to clearing, filling, excavation, grading, or planting of vegetation, as defined in LDC 2.00.00, a Vegetation Removal Permit or Exemption shall be issued by the Environmental Resources Department per LDC 6.00.03. 8. Prior to issuance of a Vegetation Removal Permit or Exemption per LDC 6.00.03, a revised tree survey and mitigation plan, respectively, shall be submitted and approved by ERD staff per LDC 11.02.09.A.2.i & 6.00.05.D. File No.: SPMj-4202126010 PDS Order No. 2023-037 Page 2 Page 98 of 428 9. Prior to commencement of development, including, but not limited to clearing, filling, excavation, grading, or planting of vegetation, as defined in LDC 2.00.00, a gopher tortoise survey shall be updated as required per state and/or federal survey protocol. J to mmencement of vel pment, ip u g, but not lim d clearing, 9Iling, ation, gra ing, r pla ing of eget ion, as d fined in C 2.00. , a Ve tation oval r it or xe ption sh a issued b Environmen ources Deoartmen er LDC 6. .03. 11VPrior to issuance of a Certificate of Occupancy, all Category I listed invasive plant species shall be eradicated from the site. B. The property on which this Minor Site Plan (Major Adjustment) is being granted is described as follows: Legal Description: The West 1 /2 of the Southeast 114 of the Northwest 1/4 of Section 12, Township 35 South, Range 38 East, St. Lucie County, Florida, less and excepting 25 foot right of way for Graves Road as recorded in Deed Book 77, Page 27B, also less and except the East 10 feet of the West 35 feet of the West 1/2 of the Southeast 1/4 of the Northwest 1/4 as recorded in O. R. Book 869, Page 8, of the Public Records of St. Lucie County, Florida. Parcel ID#: 2213-242-0001-000-8 A. The approvals granted by this Administrative Order shall expire twenty-four (24) months from the effective date, unless a Building Permit is obtained, or an extension is granted in accordance with the provisions of Section 11.02.06 of the St. Lucie County Land Development Code. If the associated Conditional Use Permit expires, the Minor Site Plan shall become invalid unless the property use is otherwise compliant with applicable Land Development Code. B. The developer, including any successors in interest, is advised as part of this Minor Plan approval that all applicable development permits and construction authorizations shall be obtained from the appropriate State, Federal, and Local regulatory agencies including, but not limited to, the United States Army Corps of Engineers, the Florida Department of Environmental Protection, South Florida Water Management District, the St. Lucie County Fire District, and the St. Lucie County Environmental Resources, Public Works, and Building Departments prior to the commencement of any development activities on the property described in Part "B". Issuance of this Order by the County does not in any way create any rights on the part of the developer to obtain a permit from a State or Federal agency and does not create any liability on the part of the County for issuance of this permit if the developer fails to obtain requisite approvals or fulfill the obligations imposed by a State or Federal agency or undertake actions that may result in a violation of State or Federal law. C. A copy of this Order shall be attached to the site plan drawings included in Exhibit "B", shall be placed on file with the St. Lucie County Planning and Development Services Department and mailed to the developer and agent of record as identified on the site plan application. File No.: SPMj-4202126010 PDS Order No. 2023-037 Page 3 Page 99 of 428 D. The conditions of approval set forth in Part "A" are an integral non -severable part of the site plan approval granted by this Order. If any condition set forth in Part "A" is determined to be invalid or unenforceable for any reason and the developer declines to comply voluntarily with that condition, the final site plan granted by this Order shall become null and void. E. The Minor Site Plan (Adjusted), attached as Exhibit "B", shall be valid for the same period as this Order. F. The Certificate of Capacity, attached as Exhibit "C", shall be valid for the same period as this Order. If this Order expires or otherwise terminates, the Certificate of Capacity shall automatically terminate. G. This Order shall become effective upon the date of approval indicated below. Should the property owner, developer or authorized agent wish to appeal any condition described in Part "A" above, all such appeals must be filed in writing with the County Administrator within thirty (30) days of the rendering of this Order, as described in Section 11.02.03(B), St. Lucie County Land Development Code. Should an appeal to this Order be filed, no permitting reviews or further administrative action shall take place on the processing of this development project until the appeal is resolved. H. This Order shall be recorded in the Public Records of St. Lucie County. r yy " ORDER effective the q ' _day of J 0"(— 2023. ATTEST: PLANNING & DEVELOPMENT SERVICES DIRECTOR, ST. LUCIE COUNTY, FLORIDA 4 BY f7 Bbnj in Balce , AICP APPROVED AS TO FORM AND CORRECTNESS: DEPUTY CLERK COUNTY A File No.: SPMj-4202126010 PDS Order No. 2023-037 Page 4 Page 100 of 428 N A Orange Avenue File No.: SPMj-4202126010 Page 5 Exhibit "A" Location Map) Subject j property A n4— ni CU r O CU 4 r t CU rl w r ,jJ z f" PDS Order No. 2023-037 1 Page 101 of 428 Exhibit "B" Site Plan) r N MR I rATfi RAN File No.: SPMj-4202126010 PIDS Order No. 2023037 Page 6 Page 102 of 428 Exhibit "C" Certificate of Capacity) St Lucie County Certificate ofCapacity Date 6;192023 Certificate Na 3.134 This document certifies that concurraency will be met andthat adequate public facility capacity exists to maintain the standards for levels of serviceas adopted in the St Lucie County Cormrehensive Plan for. I. Tvae of develooment 1DS tkdef !0I3-Q37 N umber of units 0 N umber of square feel 84;245 2 Property lenal description & Tax ID no. 12 142-0001 150 NGr"a Rand Fart Rerce FL 34945 ff-P(AK4,DIF)CitiusExpansian"IMajorAdjustmenttaalfinnrSite F1an I Awroval. Buildins Biailding Resolution No. 201-1-144 Letter 5U25 4 Subiect ID the following conditions for concurrency, Owner' s name DLF Ong LLC Address 150 N Graves RD Fast Reme FL 34945 8, Certificate E xoiration Date &19. <05 This Certificate of Capacity is transferable only fo subsequent owners of the same parcel, and is subject to the same terms, conditions and expiration date listed herein. The expiration date can be extended only underthe same terms and conditions as the underlying deve naent de issued with this certiticat orfor subsequent deveinprra or iss forthe same property, use and size as described herein. Sg Data Cr'19;30'3Planning and Development Services Director St Lucie County. Florida 3Smmdur, J1= 19,2023 File No.: SPMj-4202126010 PDS Order No. 2023-037 Page 7 Page 103 of 428 Environmental Impact Report For: 150 North Graves Road Prepared for: Douglas Feek DLF International 150 N. Graves Road Fort Pierce, FL 34945 772-257-8003 2/15/2022 ________________________________ Timothy E. Maslin, C.E.S. / C.E.C. FEC Job #22-111 Certification #77283 Page 104 of 428 Table of Contents 1.0 Executive Summary 2.0 Environmental Impact Report 2.1 Objective 2.2 Introduction 2.3 Materials and Methods 2.4 Soils 2.5 Hydrology 2.6 Flora 2.7 Fauna 2.8 Wetlands 2.9 Summary and Discussion 2.10 Conclusion and Recommendations 2.11 Qualifications of Individual Preparing Report 3.0 Appendix 3.1 Location Map 3.2 Soils Map 3.3 Topographic Map 3.4 Flood Map 3.5 Land Use Land Cover Map 3.6 National Wetland Inventory Map 3.7 Historic Aerials 3.8 Site Photos Page 105 of 428 1.0 Executive Summary The 150 North Graves Road property: • is approximately 19.34 acres in St. Lucie County, Florida. • is one partially developed parcel along Orange Avenue proposed for further land development improvements. • contains an existing citrus warehouse • contains mostly poorly drained sandy soils. • is at an elevation of approximately 21. • is in Flood Zone X. • contains an abandoned grove. • contains some native oaks and palms. • does not support protected species. • does not contain jurisdictional wetlands. • development or other improvements would cause de minimis environmental impacts. • is recommended for micro-site planning to save native trees as best practical. Page 106 of 428 2.0 Environmental Impact Report 2.1 Objective In February of 2022 Environmental Specialists from Florida Environmental Consulting Inc. performed an environmental impact study of the 150 N. Graves Rd. property for DLF International. The objective of this study was to assess and report on the baseline environmental condition of the subject site as well as to discuss how developing this site may impact the environment. 2.2 Introduction The subject property is parcel ID 2212-242-0001-000-8 and is in section 12 of township 35S, range 38E, of St. Lucie County, Florida. More specifically, on the North side of Orange Avenue, directly east of North Graves Road at 27°26'59.2"N 80°29'32.5"W. It is comprised of approximately 19.34 acres of partially developed lands, having a both a citrus warehouse and some abandoned grove on site. The facility is currently proposed for further development. Please see the maps and other reference materials in the appendix of this report. 2.3 Materials and Methods The site assessment included preliminary research of the site and surrounding area to determine what type of ecological community to expect as well as what types of individual flora and fauna may be found on site. This preliminary research included; Geographic Information Systems (GIS) Mapping, aerial interpretation, Florida Department of Environmental Protection (FDEP) Environmental Resource Analysis, and assessing the potential for species and habitats listed by the County, South Florida Water Management District (SFWMD), Florida Natural Areas Inventory (FNAI), Florida Fish and Wildlife Conservation Commission (FWC), and the U.S. Fish and Wildlife Service (FWS). The site assessment also included traversing and observing communities adjacent to and within the site. During the site assessment community types, vegetation, wildlife, and other pertinent observations were noted. 2.4 Soils According to the U.S. Department of Agriculture Natural Resources Conservation Service (NRCS) the property contains 2 major soil types more specifically described as: Soil 38, Riviera fine sand, 0 to 2 percent slopes, characterized as poorly drained sand with a water table typically about 3 to 18 inches below the surface with no typical frequency of ponding or flooding. Page 107 of 428 Soil 55, Winder loamy sand, characterized as poorly drained sand with a water table typically about 12 to 18 inches below the surface with no typical frequency of ponding or flooding Please see the soils map in the appendix of this report for the general location of these soils. 2.5 Hydrology This project is in hydrologic basin 17, the St. Lucie basin, and the United States Geological Survey (USGS) Topographic Map in the Appendix shows the area as generally flat with stormwater runoff sheet flowing to onsite stormwater drains, ponds, and onsite/adjacent stormwater canals and ditches. Using the North American Vertical Datum of 1983 (NAD83) the natural ground grade is approximately at an elevation of approximately 21, and according to the Flood Hazard Map in the Appendix, this area is not in a flood plain and as such is considered Flood Zone X. 2.6 Flora As noted in the introduction there is 1 parcel totaling approximately 19.34 acres of partially improved land, the northern half of which is LULC 2240 abandoned grove, and the remainder is LULC 1550 other light industrial including ponds and surface waters. The flora of the property has already been historically impacted by both previous agricultural uses as well as more the more recent development of the citrus warehouse packaging and shipping center, however, it did contain some native trees. Please see the Aerial LULC Map and Site Photos in the Appendix. The notable flora of the property included some live oaks (Quercus virginiana), laurel oaks (Quercus laurifolia), and cabbage palms (Sabal palmetto). The remainder of the flora consisted of exotic Brazilian Pepper (Schinus terebinthifolia), air potatoes (Dioscorea bulbifera), caesarweed (Urena lobata), muscadine grape (Vitis rotundifolia), and miscellaneous grasses and forbes as well as some landscaping plants. The stormwater ponds onsite contained cattails (Typha spp.), and dollarweed (Hydrocotyle spp.). No species of flora was observed on site listed by the County, Florida Natural Areas Inventory, Florida Fish and Wildlife Conservation Commission, or U.S. Fish and Wildlife Service, as Endangered, Threatened, or a Species of Special Concern. 2.7 Fauna Possibly due to the surrounding development and historic impacts, the fauna was found to be severely limited. The species directly observed and evidenced on site were squirrels (Sciurus carolinensis), spiders (Arachnida spp.), cattle egrets (Bubulcus ibis), ants (Formicidae spp), and anoles (Anolis spp.). No additional evidence or suspicion of use was formulated of other listed species of fauna according to the County, Florida Natural Areas Inventory, Florida Fish and Wildlife Page 108 of 428 Conservation Commission, and the U.S. Fish and Wildlife Service lists of Endangered, Threatened, and Species of Special Concern. 2.8 Wetlands Based on abandoned grove topography and aerial interpolation in conjunction with the soils survey publication; wetlands were not suspected, and this was confirmed in the field. Please see the National Wetland Inventory Map in the Appendix of this report. 2.9 Summary and Discussion In summary, the 150 North Graves Rd. property is approximately 19.34 acres of abandoned grove and existing citrus warehouse land in St. Lucie County, proposed for further development. The property is in Flood Zone X, contains poorly drained sandy soils at approximately elevation of 21 with directly adjacent and onsite drainage facilities, and does not support protected species nor jurisdictional wetlands. Finally, for discussion, the property does contain some native oaks and palms, and though these trees may be cleared with a permit, it is recommended that micro-site-planning be utilized to save these trees as best practical. 2.10 Conclusion and Recommendations In conclusion, further improvements to the 150 N. Graves Rd. property would cause de minimis adverse environmental impacts. However, it is recommended to save native trees as best practical. Please contact Florida Environmental Consulting, Inc. with any questions or comments regarding this report. Please contact Florida Environmental Consulting, Inc. with any questions or comments regarding this report or for any additional specific consulting. 2.11 Qualifications of Individual Preparing Report Florida Environmental Consulting is a Florida registered environmental consulting firm, the person who prepared this report is the president of the company, and his signature and seal on the cover of this document demonstrate that he is in responsible charge of the information provided. He is a Certified Environmental Consultant and Environmental Specialist. Additionally, he has a Bachelor of Science in Environmental Science from the University of Florida with a minor in Natural Resource Management, along with 22 years of experience. Finally, he is a member of the National Association of Environmental Professionals, and the Environmental Assessment Association where a code of ethics and personal commitment to quality work is upheld. Page 109 of 428 3.0 Appendix 3.1 Location Map 3.2 Soils Map 3.3 Topographic Map 3.4 Flood Map 3.5 Land Use Land Cover Map 3.6 National Wetland Inventory Map 3.7 Historic Aerials 3.8 Site Photos Page 110 of 428 Page 111 of 428 Page 112 of 428 Page 113 of 428 Page 114 of 428 Page 115 of 428 Field adjusted 2-9-2022 Page 116 of 428 Page 117 of 428 Page 118 of 428 Page 119 of 428 Page 120 of 428 Page 121 of 428 Page 122 of 428 Page 123 of 428 Traffic Impact Report Waiver Request - DLP Citrus SPMj-4202126010 & CUMj-4202126009 Third-Party Traffic Comment Letter • The traffic statement should calculate Daily, AM peak hour, and PM peak hour trip generation potential for the proposed development based upon rates and equations within the ITE Trip Generation Manual, 11th Edition • Per St. Lucie County LDC Section 11.02.09, a traffic study is required for a warehousing development greater than or equal to 69,000 square feet. The total development will now include approximately 85,234 square feet of warehousing, warranting a traffic study. • Main access to the facility is at Graves Road & Orange Avenue (SR 68). Daily traffic volumes along SR 68 at this location are low (AADT of 2700). Therefore, the proposed development will not greatly impact the immediate roadway network. • Since the applicant has stated that no additional employees will be hired and overall truck traffic will decrease, a traffic statement will suffice. • Traffic monitoring of the development should be performed to verify the applicant’s statement. If the statement is found to be inconsistent, a traffic impact analysis is required. Alex Memering, P.E. Kimley-Horn | 189 South Orange Avenue, Suite 1000 Orlando, FL 32801 Direct: 407 815 3572 | Main: 407 898 1511 Page 124 of 428 ITEM NO. (ID # 2024-34383) DATE: 7/18/2024 AGENDA REQUEST TO: Planning and Zoning Commission PRESENTED BY: Irene Szedlmayer, Senior Planner SUBMITTED BY: Planning & Development Services SUBJECT: Walton Ranch Petition to Rezone from AR-1 (Agricultural, Residential-1) and RM-5 (Residential Multiple-Family-5) to PUD (Planned Unit Development) and approve a Preliminary Development Plan BACKGROUND: Meritage Homes has requested to amend the Official Zoning Atlas regarding +/-45.73 acres from AR-1 (Agricultural Residential – 1, allowing up to one dwelling unit per acre (dua) and RM-5 (Residential Multiple- Family -5, allowing up to five (5) dua) to PUD (Planned Unit Development). As part of the petition to re-zone to PUD, the Applicant is also requesting approval of the Preliminary PUD Site Plan which provides for up to 141 dwellings and other site improvements. The existing Future Land Use designation is RU (Residential Urban) which permits up to five (5) dual or a total of 228.65 dwelling units. Pursuant to the existing RM-5 zoning on 18.07 acres and the AR-1 on 27.66 acres, up to 118 dwelling units would be permitted (2.6 dua) on the site. The PUD provides for 141 dwelling units which is 3.1 dua, an increase in density of 19% over that provided by the current zoning, but within the allowable Future Land Use designation density. PREVIOUS ACTION: None FINANCIAL IMPACT: No immediate or short term impact. RECOMMENDATION: Staff recommends that the Planning and Zoning Commission forward a recommendation of approval to the Board of County Commissioners, with Conditions COMMISSION ACTION: RESULT: MOVER: None SECONDER: None Page 125 of 428 AYES: None NAYS: None EXCUSED: None Coordination/Signatures Date: July 12, 2024 Benjamin Balcer, Planning & Development Services Director Date: July 12, 2024 Katherine Barbieri, Assistant County Attorney III Date: July 12, 2024 Mayte Santamaria, Deputy County Administrator Page 126 of 428 Planning and Development Services Department Planning Division M E M O R A N D U M TO:Planning and Zoning Commission THROUGH:Benjamin Balcer, AICP, Planning and Development Services Director Kori Benton, AICP, Planning Manager FROM:Irene Szedlmayer, AICP, Senior Planner DATE: July 12, 2024 SUBJECT:Walton Ranch - Petition to Amend the Official Zoning Atlas from AR-1 (Agricultural, Residential-1) and RM-5 (Residential, Multiple-Family-5) to PUD (Planned Unit Development) and requested approval of the Preliminary Site Plan GENERAL INFORMATION Property Owner Viva Communities at Silver Oaks 1, LLC and Silver Oak Drive, LLC Applicant: Meritage Homes Agent:Cotleur & Hearing Leah Heinzelman, Landscape Architect Location:East of US 1, north of Tilton Road, west of Silver Oak Drive and across an unimproved right-of-way from Savannas State Park to the north. Existing Zoning:AR-1 (Agricultural, Residential-1) and RM-5 (Residential, Multiple- Family-5) Proposed Zoning:PUD (Planned Unit Development) Future Land Use:RU (Residential Urban) Parcel ID Numbers: 3414-501-0615-000-2 and 3414-501-0602-000-8. Project No.: RZ-2312-000029 Parcel Size(s): +/-45.73 acres Proposed Uses: A residential Planned Unit Development (PUD) for up to 141 detached, single-family dwellings, preservation and restoration of 2.64-acres of wetland, stormwater, and other related development. Existing Use: Horse Stable on the north and undeveloped, native/exotic vegetation on the south. Page 127 of 428 Walton Ranch PUD-RZ- RZ-2312-000029 Page 2 Figure 1. Location and Aerial Map BACKGROUND and SUMMARY of APPLICATION Meritage Homes has requested to amend the Official Zoning Atlas regarding +/-45.73 acres from AR-1 (Agricultural Residential – 1, allowing up to one dwelling unit per acre (dua)) and RM-5 (Residential Multiple-Family -5, allowing up to five (5) dua) to PUD (Planned Unit Development). As part of the petition to re-zone to PUD, the Applicant is also requesting approval of the Preliminary PUD Site Plan which provides for up to 141 dwellings and other site improvements. The existing Future Land Use designation is RU (Residential Urban) which permits up to five (5) dua. Pursuant to the existing RM-5 zoning on 18.07 acres and the AR-1 on 27.66 acres, up to 118 dwelling units could be permitted (2.6 dua). The PUD provides for 141 dwelling units which is 3.1 dua, an increase in density of 19% over that provided by the current zoning. Subject Site Prima Vista Blvd. Crosstown Parkway U. S . H w y . 1 Tilton Rd. Page 128 of 428 Walton Ranch PUD-RZ- RZ-2312-000029 Page 3 Figure 2. Subject Site Table 1. Acreage by Current Zoning Land Area Maximum dwelling units AR-1 +/- 27.66 acres 28 RM-5 +/- 18.07 acres 90Current Zoning Total +/- 45.73 acres 118 Proposed Zoning PUD +/- 45.73 acres 141 Si l v e r O a k D r i v e Tilton Rd. Page 129 of 428 Walton Ranch PUD-RZ- RZ-2312-000029 Page 4 AMENDMENT OF ZONING ATLAS STANDARDS OF REVIEW SET FORTH IN LAND DEVELOPMENT CODE SECTION 11.06.03 Section 11.06.03 of the St. Lucie County Land Development Code (LDC) establishes the standards for reviewing proposed amendments to the Zoning Atlas. In reviewing such an application, the Planning and Zoning Commission and the Board of County Commissioners shall consider the following factors: A.Whether the proposed rezoning conflicts with any applicable portions of the St. Lucie County Land Development Code: LDC Sections 7.01.00 through 7.01.03. establish the basic standards for PUD Zoning Districts. LDC Section 7.01.01. provides that the intent of the PUD Zoning District is: “to achieve residential land development of superior quality through the encouragement of flexibility and creativity in design options that: A. Permit creative approaches to the development of residential land reflecting changes in the technology of land development; B. Allow for the efficient use of land, which can result in smaller networks of utilities and streets and thereby lower development costs; C. Allow design options that encourage an environment of stable character, compatible with surrounding land uses; and D. Permit the enhancement of neighborhoods through the preservation of natural features, the provision of underground utilities, and the provision of recreation areas and open space.” The re-zoning of the subject 45.73 acres from AR-1 and RM-5 to the Walton Ranch PUD Zoning District generally meets the intent of the PUD Zoning District and conforms with the requirements of LDC Section 7.01.02. (A) – Permitted Uses and Section 7.01.03. – Standards and Requirements. For non-PUD single-family residential development, the St. Lucie County LDC requires a minimum lot width of 75 feet and the smallest lot permitted by a standard zoning district is 8,000 sq. ft. The requested PUD proposes detached single-family residential lots that are 50 ft. wide and that mostly measure 5,750 sq. ft. (50 x 125 ft.) or 6,250 sq. ft. (50 x 125 ft.) with a few larger lots in the vicinity of the cul-de-sacs. The proposed lots “Allow for the efficient use of land, which can result in smaller networks of utilities and streets and thereby lower development costs.” In exchange for smaller lots, the proposed PUD provides 42.15% common open space, whereas conventional zoning districts require no minimum open space, whether as Page 130 of 428 Walton Ranch PUD-RZ- RZ-2312-000029 Page 5 common open space or as a minimum percentage on each residential lot. The allocation of common open space is set-forth in Table 4. As pointed out in Table 2, the Walton Ranch PUD provides 42.15% of the total site area as common open space and that calculation of total common open space includes only 1/3 of the surface water in the lakes. If the entirety of the stormwater lake tracts (4.49 acres) was included in the calculation of open space, which is permitted by the LDC, total open space would increase to 22.42 acres or 49% of total site area. Additionally, by providing for walking path and sitting areas near the stormwater lakes, the lakes are incorporated into the community as amenities that extend beyond the lots that abut a lake tract. These aspects of the Preliminary Development Plan, “permit the enhancement of neighborhoods through the preservation of natural features. . . and the provision of recreation areas and open space.” The utilities will be underground as required for PUDs. Table 2. Site Data Table ACRES % of Total Site Gross Site Area 45.73 100% Total Open Space 20.65 45% Components of Common Open Space % of Total Open Space Lakes (30% of total lake surface area)1.35 7% Lake maintenance easements & drainage 1.49 8% Preserved Wetland 2.64 14% Wetland Buffer .76 4% Recreation Areas 2.45 13% Perimeter Landscape Buffer 3.66 19% Other open space 6.93 36% Regarding the purpose for PUDs to encourage “an environment of stable character, compatible with surrounding land uses,” while the proposed Walton Ranch provides a reasonable transition between the large residential lots to the east and the RM-5 zoning to the west followed by the existing multiple family development, further west between Lennard Road and U.S. Hwy. 1., staff had suggested that some lots along Silver Oak Drive should be wider to improve the transition from the density on the east side of Silver Oak Drive (5 lots along +/- 2,500 feet) to that proposed for Walton Ranch (37 lots along the same +/- 2,500 feet), further supporting an orderly and logical development pattern. Rather than provide any wider lots, the Preliminary Development Plan widened three drainage easements from 20 feet to 30 feet, and provided for common area landscaping in those small spaces to break-up the line of continuous dwellings and proposes a 40-ft. landscape buffer along Silver Oak Drive. Page 131 of 428 Walton Ranch PUD-RZ- RZ-2312-000029 Page 6 Table 3. Proposed Walton Ranch PUD Zoning Standards MINIMUM SETBACKS LOT TYPE Front Rear Side Side at Corner Detached single- family 22 ft. 10 ft.; - 0 ft. when abutting lake; - 2 ft. for access. structures 5 ft.; - 2 ft. for access. structures 15 ft. LOT TYPE Maximum Bldg. Cover Maximum Impervious Cover Minimum Open Space Detached single- family 80%80%20% Staff has concluded that the proposed Walton Ranch PUD Zoning District is consistent with applicable LDC. B. Whether the proposed amendment is consistent with all elements of the St. Lucie County Comprehensive Plan: The proposed re-zoning to the PUD Zoning District is generally consistent with the St. Lucie County Comprehensive Plan and RU (Residential Urban) Future Land Use Category. The Goals, Objectives, and Policies of the St. Lucie County Comprehensive Plan of special relevance in review of the proposed petition include: Objective 1.1.1: Land Use. Maintain the Future Land Use Map land with the following use designations to portray the future development patterns of St. Lucie County. As provided by Comprehensive Plan Policy 1.1.1.2.H.: "The Residential Urban (RU) classification is the predominant residential land use category in the County. This residential land use category provides for a maximum density of five (5) dwelling units per gross acre. The RU designation is generally found between the identified urban service areas and the transitional RS areas. These properties need to be serviced with central water and wastewater services. These services may be provided by either a public utility or through private on-site facilities, as would be permitted in accordance with all applicable regulations. New development in the RU areas can occur Page 132 of 428 Walton Ranch PUD-RZ- RZ-2312-000029 Page 7 using traditional single-family or multifamily zoning designations or through the planned unit development process." The Walton Ranch proposed density of 3.1 dua is within the maximum density allowed in the RU Future Land Use classification and a reasonable transition between the large residential lots to the east and the RM-5 zoning to the west followed by the existing multiple family development, further west between Lennard Road and U.S. Hwy. 1. Objective 1.1.8: Planned Developments. The County shall continue to support and encourage innovative land use development patterns including planned developments through the adequate provision in the County's Land Development Code including Planned Unit Developments (PUD), Planned Non-Residential Development (PNRD) and the Planned Mixed-Use Development (PMUD) zoning designations. The proposed Walton Ranch PUD is also consistent with the following Comprehensive Plan Goals, Objectives and Policies: Objective 1.1.5 In coordination with the other elements of this plan, future development within the Urban Service Area shall be directed to areas where urban and community services/facilities can be provided in the most efficient and compact manner so as to discourage the proliferation of urban sprawl. Policy 1.1.8.1 All new subdivisions planned unit developments and site development plans shall be designed to include an efficient system of internal traffic circulation that does not require internal trips or trips of short duration to be forced onto the major roadway network. Connections to new and existing subdivisions shall be encouraged. Objective 1.1.12 Pursuant to the Land Development Code, all development orders and permits for future development and redevelopment activities shall be issued only if public facilities necessary to meet level of service standards (which are adopted as part of the Capital Improvements Element of this plan) are available concurrent with the impacts of the development. Policy 1.1.12.2 Time the development of residential, commercial, and industrial land concurrently with provision of supporting community facilities, such as streets, utilities, police and fire protection service, emergency medical service, and public schools. Goal 3.2 To provide an adequate mix of safe and sanitary housing that meets the needs of existing and future St. Lucie County residents. A finding that a proposed PUD is consistent with the St. Lucie County Comprehensive Plan includes consistency with Comprehensive Plan Policies 6.1.14.3 and 6.1.14.4., which provide that “alteration of a Category [I, II, or III] wetland or buffer may be allowed [only] when no other reasonable alternative exists and avoidance and Page 133 of 428 Walton Ranch PUD-RZ- RZ-2312-000029 Page 8 minimization of impacts cannot otherwise be achieved. Any provision of this Comprehensive Plan or the land development code related to the preservation of a Category [I, II, or III] wetland or buffer that precludes all reasonable economically viable use of the property or would prohibit a reasonable public use of the property and which if applied would result in a compensable taking of the property may be waived to the extent necessary to provide the minimum reasonable use, public or private, of the property.” Planning Staff acknowledges that an application to permit impacts to wetlands (wetland waiver application), and their respective buffers, has been submitted and is under review by the Environmental Resources Department (ERD). Section F, below, provides details of the site’s environmental conditions and proposed preservation areas. The wetlands proposed to be impacted have previously been altered and degraded by prior agricultural or development activities, and invasive species. C. Whether and the extent to which the proposed zoning is inconsistent with the existing and proposed land uses: The proposed PUD Zoning District is generally consistent with the nearby existing and proposed land uses (See Figure 3 – Zoning Map & Figure 4 -Future Land Use Map). Table 4: Future Land Use Designation, Current Zoning, and Current Land Uses of Adjacent Properties Future Land Use Zoning District Current Use North CPUB (Conservation Public) I (Institutional)Savannas State Park South RU (Residential Urban) AR-1 (Agricultural, Residential-1) and RM-5 (Residential, Multiple- Family-5) Large lot residential East RS (Residential Suburban) AR-1 (Agricultural, Residential-1) Large lot residential Ad j a c e n t L a n d West RU (Residential Urban) AR-1 (Agricultural, Residential-1) and RM-5 (Residential, Multiple- Family-5) Large lot residential and horse stables The subject parcel is located within a patchwork of several zoning districts including I (Institutional); PUD (Planned Unit Development); AR-1 (Agricultural, Residential-1), RM-5 (Residential, Multiple-Family-5), RM-9 (Residential, Multiple-Family-9). To the north, encompassing the Savannas State Park and the St. Lucie County School District property (Savanna Ridge Elementary School), is the Institutional Zoning District. Along the U.S. Highway 1 corridor and the vicinity of Prima Vista Blvd. are CG (Commercial General) and Page 134 of 428 Walton Ranch PUD-RZ- RZ-2312-000029 Page 9 some CO (Commercial Office). The Silver Oaks PUD, to the southeast of the subject site and currently under development, provides 234 townhouses and 82 detached single-family dwellings for an overall density of 2.49 dua. Figure 3. Zoning Atlas (excerpt) The Future Land Use Map also includes a mix of future land use classifications in the vicinity of the subject property—RU (Residential Urban), RS (Residential Suburban), RE (Residential Estate), RM (Residential Medium), PF (Public Facilities) and CPUB (Conservation, Public). Tilton Rd. Prima V i s t a B l v d . Si l v e r O a k s D r i v e Le n n a r d R d . I AR-1 PUD CG RF RM-9 RM-5 AR-1 Subject Site Savannah Ridge Elementary Kitterman Road US 1 Page 135 of 428 Walton Ranch PUD-RZ- RZ-2312-000029 Page 10 Figure 4. Future Land Use Map The area is experiencing change. The designation of more than half of the nearby area as Residential Urban Future Land Use (up to five dua) and one quarter as Residential Suburban Future Land Use (up to 2 dua) anticipated and provided for this change. The Silver Oaks PUD Site Plan was initially approved in 2007. Its development began in the last year or two and the construction of 316 dwelling units included the widening and paving of Tilton Road. The prevalence of wetlands on the remaining undeveloped land may reduce the density and intensity of development that occurs. Subject Site Si l v e r O a k s D r i v e Tilton Road RS RU CPUB RE RM PF US 1 Page 136 of 428 Walton Ranch PUD-RZ- RZ-2312-000029 Page 11 Figure 5. Aerial of Nearby Vicinity [Remainder of page is blank.] Si l v e r O a k s D r i v e Tilton Road US 1 Page 137 of 428 Walton Ranch PUD-RZ- RZ-2312-000029 Page 12 Figure 6. Development Projects in Nearby Vicinity Table 5. Proposals and Projects in Nearby Vicinity Project Name Proposed Development A Silver Oaks PUD •Currently under development, the Major Site Plan provides 316 dwellings (234 townhouses and 82 detached single-family dwellings) for density of 2.49 dua B S & H Business •In 2006, a request to re-zone from AR-1 to RS-2 was denied. C Sudy Perez- Lizano •In 2008, a request for FLUMA from RS to RU and re-zoning from AR-1 to RM-5 was withdrawn. D Hinkle Re-zoning •In 2022, the property was re-zoned from RM-5 to AR-1. E Bessemer Re-zoning •In 2008, the property was re-zoned from RM-5 to AR-1. A C B D G H F E Page 138 of 428 Walton Ranch PUD-RZ- RZ-2312-000029 Page 13 Project Name Proposed Development F Prima Vista Commons* •In 2005, Major Site Plan for 150 apartments on 34 acres was approved. (4.4 dua) •In 2015, a 120-unit senior housing development was approved on 13.83 acres. (8.7 dua) •In May 2022, a Major Adjustment to a Major Site Plan was approved for a 150-unit multifamily development on 19.84 acres. (7.6 dua) •In February 2024, a minor adjustment to the approved site plan was approved. G Tilton Road Dog Retreat •In 2017, a Conditional Use Permit was approved to permit construction of a 4,000 sq. ft. dog kennel was approved. CUP expired in June 2023. H Lennard Trails*•In 2005, a Major Site Plan for 120 apartments was approved (four 3-story bldgs. @ 30 units each) on 25 acres. Approval expired with no construction. (4.8 dua) * Prima Vista Commons and Lennard Trails involve overlapping land areas. The subject site is located within a land area of some 830 acres that is distinguishable from the surrounding land areas. The existing residential development in this area consists of large lots—ranging generally from +/-2.5 acres to +/- 28 acres and horse stables and horse trailers remain evident in the neighborhood. The enclave, illustrated in Figures 5 and 6, is bounded on the north and the east by the Savannas State Park; on the south by a 270-acre mobile home park; on the west by Tilton Road and Prima Vista Blvd. Surrounding these +/- 830-acres, the land uses are likely to remain as they are into the reasonably foreseeable future. D. Whether there have been any changed conditions that require an amendment. While the AR-1 and RM-5 Zoning Districts are consistent with the RU Future Land Use designation, pursuant to Comprehensive Plan Policy 1.1.1.3., the property is located within the Urban Services Boundary where development that exceeds 2 dwelling units per acre is targeted and is served by a full array of public services and facilities can be efficiently provided. Previous approvals of Silver Oaks PUD and Prima Vista Commons, and the extension of public water lines and sanitary sewer lines indicate that approval of the Walton Ranch PUD is reasonable, even if the increase in density of 19% of that permitted by the current zoning is not absolutely required. The residential population of St. Lucie County has been growing rapidly for several decades and is projected to continue to grow. The estimate of the St. Lucie County population as of April 1, 2023 is 368,628. That represents a 12% increase in just three years (U.S. Census estimate of St. Lucie County population on April 1, 2020 is 329,226.) Page 139 of 428 Walton Ranch PUD-RZ- RZ-2312-000029 Page 14 By 2050, the population of St. Lucie County is projected to increase to somewhere in the range of 406,000 to 655,400 (Source: Projections of Florida Population by County, 2025–2050, with Estimates for 2023 – BEBR). The University of Florida’s Bureau of Economic and Business Research (BEBR) believes its “medium” population projection is the most likely to provide accurate forecasts in most circumstances, which would place the St. Lucie County population at 530,700 in 2050. This represents an increase of 162,072 people or 44% from 2023. Of course, the extent of the population increase will depend on the number of dwelling units approved for development by the County, the City of Port St. Lucie, the City of Fort Pierce and St. Lucie Village. Additional housing is needed to serve existing and new residents. Table 6. Population Projections for St. Lucie County prepared by BEBR 2030 % Δ from 2023 2040 % Δ from 2023 2050 % Δ from 2023 Low projection 381,600 4%400,600 9%406,000 10% Medium projection 423,900 15%484,200 31%530,700 44% High projection 466,300 26%567,700 54%655,400 78% E. Whether and the extent to which the proposed amendment would result in demands on public facilities, and whether or to the extent to which the proposed amendment would exceed the capacity of such public facilities, including but not limited to transportation facilities, sewage facilities, water supply, parks, drainage, schools, solid waste, mass transit, and emergency medical facilities. 1. Transportation The subject site is currently served by Tilton Road and Silver Oak Drive. Tilton Road is projected to become a collector in an 80-ft right-of-way. Silver Oak Drive is a substandard road within a 100-ft right-of-way. Walton Ranch will be required to improve Silver Oak Drive for approximately 400 feet to the point of its entry road. On the north, Walton Ranch is dedicating 70 feet of right-of-way for the future Macquillen Road. Table 7 provides the net new trips expected from the Walton Ranch PUD, based on the Applicant’s Transportation Impact Report. No improvements are required to maintain the adopted Level of Service as a result of traffic generated by Walton Ranch. Certain improvements are needed at the intersection of Prima Vista Blvd. and US Hwy. 1 to maintain the LOS based on background growth in traffic. The County’s independent, third-party reviewer has accepted the Applicant’s TIR. Page 140 of 428 Walton Ranch PUD-RZ- RZ-2312-000029 Page 15 Table 7. Trip Generation VEHICLE TRIPS DAILY AM PEAK HOUR PM PEAK HOUR 1,474 108 146 IN OUT IN OUT 28 80 92 54 Interior Streets The local roads, interior to the residential neighborhoods, will be constructed within a 50- ft. right-of-way and include 10-ft travel lanes. Five-ft. sidewalks will be provided on both sides of the main north-south street, but sidewalks will be limited to one side on the two short east-west cul-de-sacs, and the shorter segments of Equas Circle and Stallion Lane. This is consistent with LDC Section 7.05.04.A.3. which provides that “Local streets shall have sidewalks five (5) feet wide along one (1) or both sides of the street as deemed necessary during the County's development review process.” 2. Transit The nearest public transit is on U.S. Hwy. 1. Shown in red on Figure 7, the Route 1 has hourly service both northbound and south bound on U.S. 1 between 7 am and 8 pm on weekdays, with more limited service on weekends and holidays. The low densities in the area east of U.S. Hwy. 1, including the subject site, are unlikely to be served by transit other than the service on Route 1. Figure 7. Excerpt of SLC ART (Area Regional Transit) Route Map Subject Site Page 141 of 428 Walton Ranch PUD-RZ- RZ-2312-000029 Page 16 3. Water and Wastewater The subject property is within the City of Port St. Lucie’s Utilities Service Area and public water and sanitary sewer service will be provided by it. The project proposes to connect to an existing 8-inch sanitary sewer force main and to connect to an existing 12-inch water line, both within the Tilton Road ROW. 4. Parks The subject site has enviable proximity to the Savannas State Park and will be proximate to the multi-use (bicycle and pedestrian) path planned to connect Walton Road to Savannas Road in Fort Pierce. The Savannas Ridge Elementary School has a basketball court and a playground but these recreational assets are located within the school’s secured area and not available to residents. The Preliminary Development Plan provides for passive recreation in the form of walking paths that provide benches near the stormwater lakes and the to-be-restored wetland. Comprehensive Plan Recreation Element strives to support an adequate and equitable distribution of parks, recreation, and open spaces throughout the county to provide a range of activities for residents and visitors. The Comprehensive Plan Level of Service (LOS) standards for parks and recreation are as follows: • Community parks: 5 acres/1000 residents in the unincorporated area; • Regional parks: 2.5 acres/1000 population county-wide; and • Resource-based parks: 21.2 acres/1000 population county-wide. Assuming the average 2.62 persons per household, Walton Ranch can be expected to have about 370 residents, thereby creating the need for 1.85 acres of community parks, 0.93 acres of regional parks and 7.8 acres of resource-based parks. Walton Ranch will generate some $300,859 in County Park Impact Fees ($2,133.75 per single- family dwelling) to help meet the adopted Park Level of Service. 5. Drainage The subject site is located in Flood Zone X, an area determined by the Flood Insurance Rate Map (FIRM) to be an area of minimal flood risk. Pursuant to LDC Section 7.07.01., Walton Ranch is required to: “Protect the surface water, groundwater and other natural resources by ensuring that stormwater runoff peak discharge rate, volumes, and pollutant loadings are managed to minimize the adverse impacts of erosion, sedimentation, flooding, and water pollution” by meeting the standards established by the South Florida Water Management District and the LDC for the design and construction of all surface water management systems. The project’s conceptual drainage plan proposes a 20-ft drainage easement aligned with the future Macquillen Road to a roadside swale on Lennard Road to an existing stormwater pond, to the NSLRWCD Canal No. 28, and, then, apparently to the St. Lucie River. Page 142 of 428 Walton Ranch PUD-RZ- RZ-2312-000029 Page 17 While the subject property is identified as Flood Zone X on the FIRM, there are many wetlands in the surrounding area. 6. Schools This proposed PUD Zoning District will create demand on school capacity. The St. Lucie County School District utilizes a student generation rate of 0.405 students per single-family dwelling. Therefore, 57 students can be expected from Walton Ranch (40 K-8 students (70%) and 17 high school students (30%)). School impact fees of $6,786 per single-family dwelling are intended to help the District provide the needed capacity. The proposed residential neighborhood is within walking/biking distance to the Savanna Ridge Elementary School; the school is about ½ mile from the northern property line of the subject property. The subject site is about 5 miles from Port St. Lucie High School, via U.S. Highway 1. Currently, there is no public street network to enable a more direct route to the school. If the proposed Lennard Road connection or the Savannas bicycle trail are realized, the distance to the school is shortened by two miles. 7. Fire Protection and Emergency Medical Services The subject site is approximately equal distance from three St. Lucie County Fire District stations—Station 6 at 350 E. Midway Road; Station 3 at 480 SW Ravenswood Lane; and Station 12 at 1850 SE Village Green Drive. Figure 8. Nearest Fire Stations = Fire Station Page 143 of 428 Walton Ranch PUD-RZ- RZ-2312-000029 Page 18 F. Whether and the extent which the proposed amendment would result in significant adverse impacts on the natural environment: The Environmental Resources Department (ERD) reviewed the application and provided this summary: The Environmental Impact Report (EIR) prepared by Aquatic Research, Monitoring, Equipment, & Deployment, LLC, dated June 2024, was reviewed. No native upland habitat was identified onsite. The northern half of the property contains improved pasture and currently serves as a horse boarding facility. The southern half of the property is vacant land overgrown with invasive vegetation, which was also previously impacted by agricultural activity. Observed native vegetation includes cabbage palms, live oaks, laurel oaks, and maiden cane. Observed non-native vegetation includes a variety of pasture grasses, Brazilian pepper, melaleuca, shoe button ardisia, java plum and Peruvian primrose-willow. No listed species were observed during field surveys. A 100% gopher tortoise survey in accordance with Florida Fish and Wildlife Conservation Commission will be required prior to development activities. Two (2) other surface water (OSWs) bodies, a ditch system and a 0.1-acre artificial pond, along with four (4) isolated low to moderate quality Category III wetlands, respectively measuring 0.1-acres (Wetland 1), 2.9-acres (Wetland 2), 0.2-acres (Wetland 3), and 1.3-acres (Wetland 4), were identified onsite. Wetland 1 is best classified as an exotic hardwood wetland, Wetlands 2 and 3 as vegetated non-forested wetlands, and Wetland 4 as a maiden cane wetland. The limits of the four (4) wetlands were verified by the South Florida Water Management District (SFWMD) via an informal wetland determination (No. 56-107164-P) for Wetlands 1, 2, & 3 located within the southern parcel, and a formal wetland determination (No. 56-110381-P) for Wetland 4 located within the northern parcel. The development proposes impacts to both OSWs, 1.8 acres of direct wetland impacts, 0.09 acres of indirect wetland impacts, and 2.7 acres of wetland preservation and restoration. More specifically, the entirety of Wetlands 1, 3, and 4, along with 0.2 acres of Wetland 2 are proposed to be impacted. The remaining 2.7 acres of Wetland 2 and surrounding twenty-five (25) ft. wide upland buffer, will be restored, maintained, and protected in perpetuity by a conservation easement and a preserve area monitoring and management plan. No mitigation will be required by SFWMD for the impacts to Wetlands 1 or 3 as both measure under a half of an acre. According to the provided uniform mitigation assessment method (UMAM) scores, the restoration of the remaining Wetland 2 acreage (2.7 acres) will provide 0.57 units of excess mitigation credit after accounting for the impacts (1.5 acres) to Wetland 2 & 4. This indicates that no purchase of wetland mitigation bank credits will be required, which will be verified via receipt of the project’s Environmental Resource Permit issued by SFWMD. A landscape plan prepared by Cotleur & Hearing, dated June 17th, 2024, was found to be consistent with the standards for preliminary plans outlined in Page 144 of 428 Walton Ranch PUD-RZ- RZ-2312-000029 Page 19 LDC 11.02.10.A.3. A six (6) ft. tall PVC fence with augmented landscaping is proposed within a forty (40) ft. wide landscape buffer along the eastern perimeter abutting the Silver Oak Drive right-of-way to help buffer existing single-family residences to the east. A twenty-five (25) ft. wide landscape buffer is provided along the northern and western perimeters to help buffer the Savannas Preserve State Park to the north and the existing business to the west. The proposed project will impact a total of approximately twenty- four (24) cabbage palms and 1,140 inches diameter at breast height (DBH) of native canopy trees meeting minimum mitigation size thresholds outlined in LDC 6.00.05.D, resulting in a total of twenty-four (24) cabbage palms and 2,280 inches DBH of required tree mitigation. A total of six (6) cabbage palms and 522 inches of oaks and slash pines are proposed to be preserved onsite, which equates to six (6) cabbage palms and 1,044 inches of preservation credit. Currently, a total of eighteen (18) cabbage palms and 622.5 inches DBH of live oak and slash pine are proposed to be planted onsite. The remaining 613.5 inches DBH of required mitigation is to be met via a fee-in- lieu, additional preservation, and/or additional plantings of native canopy trees, consistent with the tree mitigation standards outlined within LDC 6.00.05.D. Figure 9. Excerpt from Applicant’s EIR showing wetlands proposed to be preserved and proposed to be impacted. = restored & preserved = impacted Page 145 of 428 Walton Ranch PUD-RZ- RZ-2312-000029 Page 20 G. Whether and the extent to which the proposed amendment would adversely affect property values in the area. The proposed zoning change will not have an adverse impact on property values in the area. The Preliminary Development Plan promises to promote a development of stable character and is generally compatible with the current and proposed surrounding land uses. H. Whether and the extent to which the proposed amendment would result in an orderly and logical development pattern specifically identifying any negative effects of such patterns. The proposed lots are substantially smaller than those in the surrounding area and the density is substantially higher than existing development. While the subject site evokes rural St. Lucie County, it is located in an urbanizing portion of the County and the proposed development is consistent with the RU (Residential Urban) Future Land Use designation. The proposed density of 3 dua provides a transition from lower residential density to the east and higher residential density to the west. While the Silver Oaks PUD has a lower density (2.49 dua), the Silver Oaks site also contains substantial wetlands. Therefore, overall, the proposed PUD zoning will contribute to an orderly and logical pattern in the nearby vicinity. I. Whether the proposed amendment would conflict with the public interest and is in harmony with the purpose and intent of this Code. The proposed PUD Zoning District does not conflict with the public interest and is in harmony with the purpose and intent of the St. Lucie County Land Development Code. The PUD Zoning District will provide housing proximate to employment, commercial goods and services, a state park for passive recreation, and schools. J. Any other matters that may be deemed appropriate by the Planning and Zoning Commission or the Board of County Commissioners, in review and consideration of the proposed amendment. The Planning and Zoning Commission and the Board of County Commissioners may raise other matters regarding this proposed amendment to the Official Zoning Atlas. SUMMARY OF ANALYSIS: Based upon the facts and analysis summarized in this report, the proposed rezoning from AR-1 and RM-5 to the PUD (Planned Unit Development), subject to the conditions identified in the Staff Recommendation, is consistent with the St. Lucie County Comprehensive Plan and Land Development Code. ****************************************************************************** Page 146 of 428 Walton Ranch PUD-RZ- RZ-2312-000029 Page 21 PRELIMINARY PUD SITE PLAN STANDARDS OF REVIEW SET FORTH IN LAND DEVELOPMENT CODE SECTION 11.02.07 Section 11.02.07. of the St. Lucie County Land Development Code (LDC) establishes the Standards of Review for Site Plans for Planned Development. The factors set forth in LDC Section 11.02.07. A. through. F. are essentially the same factors that must be considered when reviewing an application to amend the Zoning Atlas. A.Consistency with Local Ordinances and Comprehensive Plan. Pages 4 through 8 of the Staff Report review the consistency of the proposed Walton Ranch PUD Zoning District, including the PUD Preliminary Site Plan with applicable Comprehensive Plan Goals, Objectives and Policies and applicable regulations in the LDC. Staff has concluded that the Preliminary Development Plan is generally consistent with the LDC and Comprehensive Plan. B.Effect on Nearby Properties. A discussion of how the proposed development may affect nearby properties is discussed above. While the proposed PUD will reduce the rural quality of the surrounding area, the proposed PUD will provide a transition between the larger parcels generally to the east and increased density permitted to the west. No unreasonable adverse impacts should be experienced by nearby properties as a result of this PUD. C.Adequacy of Public Facilities The Applicant has filed an Affidavit of Deferral of Concurrency. The adequacy of public facilities and services to serve the residential development proposed by the Preliminary Development Plan is discussed on pages 14 through 17. Approval of Final Development Plans will be contingent upon demonstration that Adopted Levels of Service for all public facilities and services will be maintained. A Certificate of Capacity is required for all final development orders. D.Adequacy of Fire Protection. Three different fire stations are available to provide timely response to the proposed development. The Applicant has filed an Affidavit of Deferral of Concurrency. Approval of Final Development Plans will be contingent upon demonstration that Adopted Levels of Service for fire protection and emergency services will be maintained. E.Adequacy of School Facilities. A rough estimate of the students to be expected to reside in the Walton Ranch PUD Zoning District is 57 (40 K-8 students and 17 high school students). The Applicant has filed an Affidavit of Deferral of Concurrency. Approval of Final Development Plans will be contingent upon demonstration that adequate capacity is available for the children who will reside in the new neighborhood. The closed school, Savannah Ridge Elementary is situated along Lennard Road to the northwest. Page 147 of 428 Walton Ranch PUD-RZ- RZ-2312-000029 Page 22 F.Environmental Impact. The Environmental Resources Department has reviewed the Preliminary Development Plan and the application for a wetland waiver. The environmental impact of the proposed residential development is discussed on pages 18 and 19. Staff concludes that the environmental impact is consistent with applicable policies and regulations, subject to certain conditions of approval. Figure 9. Proposed Preliminary Development Plan Si l v e r O a k D r i v e Tilton Road Page 148 of 428 Walton Ranch PUD-RZ- RZ-2312-000029 Page 23 NOTICE Proper public notice consistent with the requirements of the LDC was provided for the public hearing before the Planning and Zoning Commission. On July 6, 2024, notice was mailed to all owners of property within 500 feet of the subject property. On July 2, 2024, a sign was installed on the property. An advertisement was published in the St. Lucie News Tribune on July 3, 2024. NEIGHBORHOOD MEETING The Applicant did not hold a neighborhood meeting. STAFF RECOMMENDATION Staff recommends that the Planning and Zoning Commission forward a recommendation of approval to the Board of County Commissioners for the amendment of the Zoning Atlas to PUD and the Walton Ranch Preliminary Development Plan, subject to the following conditions: 1) Prior to final site plan approval, a finalized tree mitigation plan consistent with Land Development Code 6.00.05.D shall be provided. 2) Prior to final site plan approval, a finalized landscape plan consistent with Land Development Code 7.09.00 shall be provided, which includes the following revisions: a. Specify all proposed canopy trees utilized to fulfill landscaping and upland buffer requirements, including green buttonwoods, red maples, and bald cypress, to measure a minimum of two and a half (2.5) inches diameter at breast height (DBH) and five (5) ft. crown spread in accordance with LDC 7.09.03.E.2.d. b. A root barrier typical consistent with LDC 7.09.03.E.2.e and corresponding root barrier locations shall be provided for those trees whose roots are known to cause damage to public roadways or other public works and are planted closer than twelve (12) feet to such public roads or works. c. Number the canopy trees to be preserved as to correlate to the tree mitigation plan. 3) Prior to final site plan approval, relabel the thirty (30) ft. wide area that lies between Lots 136-140 on the site plan as a ‘modified transitional upland buffer’. 4) Prior to final site plan approval, provide a revised boundary survey that depicts the limits of the three (3) wetlands located on the south parcel (Parcel ID 3414-501-0615-000-2) in accordance with LDC 11.02.09.A. 5) Prior to commencement of development, including, but not limited to clearing, filling, excavation, grading, or planting of vegetation, as defined in LDC 2.00.00, the developer shall provide an executed Conservation Easement over the onsite wetland and associated upland buffer, along with the approved Preserve Area Monitoring and Management Plan (PAMMP), with an attached affidavit and cashier's check (payable to the Clerk of the Court for recording fees) to the County Attorney. The applicant shall also provide a georeferenced GIS shapefile or CAD file of the conservation easements’ boundaries to St. Lucie County. 6) Prior to commencement of development, including, but not limited to clearing, filling, excavation, grading, or planting of vegetation, as defined in LDC 2.00.00, updated listed species surveys shall be provided per state and/or federal survey protocol. Should any listed species be found as a result of these surveys, appropriate permits from state and federal agencies shall be required. Page 149 of 428 Walton Ranch PUD-RZ- RZ-2312-000029 Page 24 7) Prior to issuance of a Certificate of Occupancy, all Category I listed invasive plants shall be eradicated from the site. Page 150 of 428 Resolution No. 2024- Page 1 File No.: PUD-RZ-2312-000029 RESOLUTION 2024-XX File Number: PUD-RZ-2312-000029 A RESOLUTION OF THE BOARD OF COUNTY COMMISSIONERS OF ST. LUCIE COUNTY AMENDING THE OFFICIAL ZONING ATLAS FROM THE AR-1 (AGRICULTURAL, RESIDENTIAL-1) (+/-27.66 ACRES) AND RM-5 (RESIDENTIAL, MULTIPLE FAMILY-5) (+/- 18.07 ACRES) ZONING DISTRICTS TO THE PUD (PLANNED UNIT DEVELOPMENT) (+/- 45.73 ACRES) ZONING DISTRICT AND APPROVING A PRELIMINARY DEVELOPMENT PLAN WHICH PROVIDES FOR 141 SINGLE-FAMILY DWELLINGS WITH SUPPORTING INFRASTRUCTURE AND OPEN SPACE LOCATED WITHIN ST. LUCIE COUNTY, FLORIDA. WHEREAS, the Board of County Commissioners of St. Lucie County, Florida, based upon acceptable evidence, including but not limited to the staff report, has made the following determinations: ZONING ATLAS AMENDMENT 1) Meritage Homes presented a petition to amend the Official Zoning Atlas from the AR-1 (Agricultural, Residential – 1) and RM-5 (Residential, Multiple-Family- 5) Zoning Districts to the PUD (Planned Unit Development) Zoning District, for certain property in St. Lucie County, Florida, located north of Tilton Road and east of Silver Oak Drive, as depicted on the attached map as Exhibit A and described in Part A below. 2) After installation of signs on the property, notice was mailed to all owners of property within 500 feet of the subject property, and notice was published in the St. Lucie News Tribune at least 10 days before the hearing, on July 18, 2024, the St. Lucie County Planning and Zoning Commission held a public hearing on this petition, at which all interested persons were given an opportunity to be heard and recommended that the Board of County Commissioners approve or deny the request for the property described in Part A. 3) The St. Lucie County Development Review Committee has reviewed the Rezone Petition and found it to meet the technical requirements and to be consistent with the St. Lucie County Comprehensive Plan, subject to the conditions set forth in Part C of this Resolution. 4) The proposed zoning change is consistent with the St. Lucie County Comprehensive Plan and has satisfied the requirements of Section 11.06.03. of the St. Lucie County Land Development Code. Page 151 of 428 Resolution No. 2024- Page 2 File No.: PUD-RZ-2312-000029 PRELIMINARY PUD SITE PLAN 5) Meritage Homes submitted a Preliminary Development Plan for development of the Walton Ranch PUD, for up to 141 (one hundred forty-one) detached, single- family dwelling units and other related development, for the property depicted in the attached map as Exhibit A and described in Part A below. 6) After installation of signs on the property, notice was mailed to all owners of property within 500 feet of the subject property, and notice was published in the St. Lucie News Tribune at least 10 days before the hearing, on July 18, 2024, the St. Lucie County Planning and Zoning Commission held the public hearing on this petition, at which all interested persons were given an opportunity to be heard and recommended that the Board of County Commissioners approve or deny the request for the property described in Part A. 7) After installation of signs on the property, notice was mailed to all owners of property within 500 feet of the subject property, and notice was published in the St. Lucie News Tribune at least 10 days before the hearing, on ______________, 2024, the Board of County Commissioners held a public hearing on this petition, at which all interested persons were given an opportunity to be heard. 8) The St. Lucie County Development Review Committee has reviewed the Preliminary PUD Site Plan for the project and found it to meet the technical requirements and to be consistent with the St. Lucie County Comprehensive Plan, subject to the conditions set forth in Part C of this Resolution. 9) The proposed project, with conditions of approval, will not have an undue adverse effect on adjacent property, the character of the neighborhood, traffic conditions, parking, utility facilities or other matters affecting the public health, safety, and general welfare. 10) All reasonable steps have been taken to minimize any adverse effect of the proposed project on the immediate vicinity through building design, site design, landscaping, and screening. 11) The proposed project will be constructed, arranged, and operated so as not to interfere with the development and use of neighboring property, in accordance with applicable district regulations. 12) The proposed project will be served by the City of Port St. Lucie Utility Systems Department for water and wastewater services. Page 152 of 428 Resolution No. 2024- Page 3 File No.: PUD-RZ-2312-000029 NOW, THEREFORE, BE IT RESOLVED by the Board of County Commissioners of St. Lucie County, Florida: ZONING ATLAS AMENDMENT A. The property on which the Zoning Atlas Amendment, or change in zoning, from AG-1 (Agricultural-1), AR-1 (Agricultural, Residential – 1) and RM-5 (Residential, Multiple Family-5) Zoning Districts to the PUD (Planned Unit Development) Zoning District, is being granted is described as follows: Lots 1, 2, 3, 15 and 16, Block 2, Plat No. 1, St. Lucie Gardens, Section 23, Township 36 South, Range 40 East, according to the map or plat thereof, recorded in Plat Book 1, Page 35, Public Records of St. Lucie County, Florida. CONTAINING 45.733 ACRES MORE OR LESS Parcel ID Numbers: 3414-501-0615-000-2 and 3414-501-0602-000-8 B. The St. Lucie County Planning and Development Services Director shall be authorized to amend the Official Zoning Map to change the zoning of the property herein described, from the AR-1 (Agricultural, Residential – 1) and RM-5 (Residential, Multiple-Family-5) Zoning Districts to the PUD (Planned Unit Development) Zoning District, and to make notation of the reference to the date of adoption of this Resolution. PRELIMINARY PUD SITE PLAN C. Pursuant to 11.02.05.B. of the St. Lucie County Land Development Code, the PUD (Planned Unit Development) Preliminary Site Plan including the request for a Wetland Waiver for the project known as Walton Ranch PUD is hereby approved, for the subject property described in Part A above, as shown on the preliminary site plan drawings for the project, prepared by Cotleur & Hearing, Inc.. and dated __________ , 2024, and date stamped received by the St. Lucie County Planning & Development Services Department on_____________, as attached and incorporated herein as Exhibit C, and subject to the following conditions: 1. Prior to final site plan approval, a finalized tree mitigation plan consistent with LDC 6.00.05.D shall be provided. 2. Prior to final site plan approval, a finalized landscape plan consistent with LDC 7.09.00 shall be provided, which includes the following revisions: a. Specify all proposed canopy trees utilized to fulfill landscaping and upland buffer requirements, including green buttonwoods, red maples, and bald cypress, to measure a minimum of two and a half (2.5) inches diameter at Page 153 of 428 Resolution No. 2024- Page 4 File No.: PUD-RZ-2312-000029 breast height (DBH) and five (5) ft. crown spread in accordance with LDC 7.09.03.E.2.d. b. A root barrier typical consistent with LDC 7.09.03.E.2.e and corresponding root barrier locations shall be provided for those trees whose roots are known to cause damage to public roadways or other public works and are planted closer than twelve (12) feet to such public roads or works. c. Number the canopy trees to be preserved as to correlate to the tree mitigation plan. 3. Prior to final site plan approval, relabel the thirty (30) ft. wide area that lies between Lots 136-140 on the site plan as a ‘modified transitional upland buffer’. 4. Prior to final site plan approval, provide a revised boundary survey that depicts the limits of the three (3) wetlands located on the south parcel (Parcel ID 3414- 501-0615-000-2) in accordance with LDC 11.02.09.A. 5. Prior to commencement of development, including, but not limited to clearing, filling, excavation, grading, or planting of vegetation, as defined in LDC 2.00.00, the developer shall provide an executed Conservation Easement over the onsite wetland and associated upland buffer, along with the approved Preserve Area Monitoring and Management Plan (PAMMP), with an attached affidavit and cashier's check (payable to the Clerk of the Court for recording fees) to the County Attorney. The applicant shall also provide a georeferenced GIS shapefile or CAD file of the conservation easements’ boundaries to St. Lucie County. 6. Prior to commencement of development, including, but not limited to clearing, filling, excavation, grading, or planting of vegetation, as defined in LDC 2.00.00, updated listed species surveys shall be provided per state and/or federal survey protocol. Should any listed species be found as a result of these surveys, appropriate permits from state and federal agencies shall be required. 7. Prior to issuance of a Certificate of Occupancy, all Category I listed invasive plants shall be eradicated from the site. D. The Preliminary PUD Site Plan approval granted by this Resolution shall expire on ____________, 2026 unless a Final Site Plan is obtained, or an extension is granted in accordance with Section 11.02.06.B.3. of the Land Development Code. E. The developer is advised as part of this approval that the property owner(s), developer, etc., including any successors in interest, shall obtain all applicable development permits and construction authorizations from the appropriate State and Federal and local regulatory agencies including, but not limited to, the United States Army Corps of Engineers, the Florida Department of Environmental Protection, Florida Department of Transportation, South Florida Water Management District, and the St. Lucie County Environmental Resources, Public Works, and Building Departments prior to the commencement of any development activities on the property described in Part A. Issuance of this authorization or Page 154 of 428 Resolution No. 2024- Page 5 File No.: PUD-RZ-2312-000029 permit by the County does not in any way create any rights on the part of the developer to obtain a permit from a State or Federal agency and does not create any liability on the part of the County for issuance of this permit if the developer fails to obtain requisite approvals or fulfill the obligations imposed by a State or Federal agency or undertake actions that may result in a violation of State or Federal law. F. The conditions set forth in Part C above are an integral non-severable part of the Preliminary Site Plan approval granted by this Resolution. If any condition set forth in Part C above is determined to be invalid or unenforceable for any reason and the developer declines to comply voluntarily with that condition, the Preliminary Site Plan approval granted by this Resolution shall become null and void. G. A Concurrency Deferral Affidavit, a copy of which is attached hereto as Exhibit B and made a part hereof the Resolution, was signed by the applicant on December 22, 2023. H. A copy of this Resolution shall be provided to the owner of record as identified on the application. I. This Resolution shall be recorded in the Public Records. J. ADOPTION After motion and second, the vote on this Resolution was as follows: Cathy Townsend, Chair XXX Chris Dzadovsky, Vice-Chair XXX Larry Leet, Commissioner XXX Linda Bartz, Commissioner XXX Jamie Fowler, Commissioner XXX Page 155 of 428 Resolution No. 2024- Page 6 File No.: PUD-RZ-2312-000029 PASSED AND DULY ADOPTED this _______ day of ________________, 2024. BOARD OF COUNTY COMMISSIONERS ST. LUCIE COUNTY, FLORIDA BY: ______________________________ CHAIR ATTEST: APPROVED AS TO FORM AND CORRECTNESS: ___________________ BY: ______________________________ DEPUTY CLERK COUNTY ATTORNEY Page 156 of 428 Resolution No. 2024- Page 7 File No.: PUD-RZ-2312-000029 EXHIBIT A (LOCATION MAP) Page 157 of 428 Resolution No. 2024- Page 8 File No.: PUD-RZ-2312-000029 EXHIBIT B (Concurrency Deferral Affidavit) Page 158 of 428 Resolution No. 2024- Page 9 File No.: PUD-RZ-2312-000029 EXHIBIT C (PRELIMINARY PUD SITE PLAN) Page 159 of 428 St. Lucie County Planning and Development Services 2300 Virginia Avenue Fort Pierce, FL 34982 Walton Ranch Rezoning to PUD December 22, 2023 Site Data Parcel 1 Parcel 2 Parcel ID 3414-501-0615-000-2 3414-501-0602-000-8 Acreage* 18.07 27.66 Owner Viva Communities At Silver Oaks 1 LLC Silver Oak Drive, LLC Land Use RU RU Zoning RM-5 AR-1 Proposed Zoning PUD PUD *Per St. Lucie County Property Appraiser Introduction On behalf of the applicants, Viva Communities At Silver Oaks 1 LLC and Silver Oak Drive, LLC, Cotleur & Hearing is submitting the following information as justification for the rezoning to PUD for the desired development. Narrative The Applicant is seeking approval to rezone the subject properties from RM-5 and AR-1 to PUD. The proposed site plan is designated to be a Planned Unit Development in accordance with the St. Lucie County Land Development Code Section 7.01.00. As described in the LDC, the PUD is “intended to achieve residential land development of superior quality through the encouragement of flexibility and creativity in design options.” The properties to be rezoned are a combined 45.73 Acres, satisfactory to the contiguous 5 acre minimum requirement for a Planned Unit Development. This site location and rezoning aims to create more homeownership opportunities in the county, in accordance with Objective 3.1.1 of the St. Lucie County Comprehensive Plan: “The County shall ensure the creation and/or preservation of affordable housing for all current and anticipated future residents of the jurisdiction”, through the development of one-hundred-thirty nine (139) 50’ single family home lots. I trust that the answers to the comments included in this submittal are complete and will allow this project to be approved at the earliest possible date. Please contact this office with any questions you may have in your review of this information. Sincerely yours, Leah Heinzelmann, PLA, ASLA Associate Partner, Cotleur & Hearing 1934 Commerce Lane, Suite 1 Jupiter, FL 33458 Page 160 of 428 SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWM WM WM WMWMWM WM WM WMWMWM WM WM WMWMWM WM WM WMWMWM WM WM WMWMWM WM WM WMWMWM WM WM WMWMWM WM WMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SSSSSS SS SS SS SSSSSS SS SS SSSSSS SS SS SS SSSSSS SS SS SS SSSS SS SS SS SS SSSSSSSSSSSSSSSSSSSSSSSSFM FM FM FM FM FMFMFMFMFMFMFMFMFMFMFMFMFM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS 33 0 ' 66 0 ' 1320' 1320' LAKE 3 (2.38 AC TRACT) 15 5 - 5 0 ' X 1 1 5 ' S I N G L E F A M I L Y L O T S OS 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM LAKE 2 (0.88 AC TRACT) LAKE 1 (1.23 AC TRACT) 1LOT WETLAND (2.64 AC TRACT) WETLAND (.76 AC TRACT) BUFFER 2LOT 3LOT 4LOT 5LOT 6LOT 7LOT 8LOT 9LOT 10LOT 11LOT 12LOT 13LOT 14LOT 15 LOT 16LOT 17LOT 18LOT 19LOT 20LOT 21LOT 22LOT 23LOT 24LOT 25LOT 26LOT 27LOT 28LOT 29LOT 30LOT 31LOT 32LOT 33LOT 34LOT 35LOT 36LOT 37LOT 38LOT 39LOT 40LOT 41LOT 42LOT 43LOT 44LOT 45LOT 46LOT 47LOT48LOT49LOT50LOT51LOT52LOT53LOT 54LOT55LOT 56LOT57LOT58LOT59LOT60LOT61LOT62LOT 63LOT64LOT65LOT66LOT 67LOT 68LOT 109LOT 110LOT 111 LOT 112LOT 113LOT 114LOT 116LOT 117LOT 118LOT 119LOT 120LOT 121LOT 122LOT 127LOT 126LOT 125LOT 124LOT 123LOT 131LOT 130LOT 129LOT 128LOT 132LOT 133LOT 134LOT 135LOT 141LOT 140LOT 136LOT 137LOT 139LOT 138LOT 82LOT 83LOT84LOT85LOT86LOT 87LOT88LOT 89LOT90LOT 106LOT105LOT104LOT103LOT102LOT 101LOT100LOT 99LOT98LOT 91LOT 97LOT 92LOT 93LOT 94LOT 95LOT 96LOT 115LOT 69LOT 70LOT 81LOT 80LOT 79LOT 71LOT 72LOT 73LOT 74LOT 78LOT 77LOT 76LOT 75LOT REC OPEN SPACE 1289' 61 0 ' SAVANNAHS PRESERVE STATE PARK SILVER OAK DRIVE Mc Q U I L L E N R O A D TI L T O N R O A D R35'R35' LIFT STATION 108LOT 107LOT 10' 20' DE EQUUS CIRCLE EQUUS CIRCLE EQUUS CIRCLE EQUUS CIRCLE EQ U U S C I R C L E EQ U U S C I R C L E ST A L L I O N L A N E TA N D E M T E R R A C E VA N N E R W A Y 5' SW, TYP 50' 50' ROW 25' LB 50' ROW 24' ROAD 11' LANDSCAPE ISLAND WITHOUT SIDEWALK, TYP. 6' LANDSCAPE ISLAND WITH SIDEWALK, TYP. 5' SW, TYP. 20' UE 10' DE 115' 115' 20' DE20' DE 30' DE/ CA 40' LB 20' LME 350' 30' DE/ CA 30' DE/ CA 50' ROW PROPOSED ENTRY SIGN 25'5' PROPOSED SW CALL BOX 25.2' 25' BUFFER 20' SECONDARY EMS STABILIZED ACCESS PROPOSED ENTRY GATES MAIL KIOSK AMENITY AREA TRASH & PET RECEPTACLES BIKE RACK, TYP. BENCH, TYP. REST AREA STABILIZED WALKING PATH SIGHT TRIANGLE, TYP. SCHOOL BUS STOP, TYP. STABILIZED WALKING PATH STABILIZED WALKING PATH STABILIZED WALKING PATH TO CONNECT TO NEARBY SCHOOL DISTRICT CROSSWALK, TYP. REST AREA STOP SIGN & STOP BAR, TYP. 6' PVC FENCE WITH MEANDERING LANDSCAPE BUFFER LIGHT POLE, TYP. 50' ROW 50' ROW 20' LME 20' LME 40' LB 50' ROW 25' LB 25' LB 25' LB 70' ROW DEDICATION 2' VG, TYP. TURN-AROUND, TYP. TURN-AROUND, TYP. TURN-AROUND, TYP. PROPERTY BOUNDARY 78.3' 125' 30' 30' WETLAND IMPACT GRADE 4:1 TO MEET ELEVATION OF WETLAND R50' R50' REC OPEN SPACE REC OPEN SPACE REC OPEN SPACE REC OPEN SPACE REC OPEN SPACE REC OPEN SPACE REC OPEN SPACE 1 50' Scale: 1" = 100' 0'100'300'200' North 400' PUD MASTER PLAN by agreement in writing with the architect. Immediately report any discrepancies to the architect. SHEET COTLEUR & HEARING, INC. These drawings are the property of the architect and are not to be used for extensions or on other projects except OF DESIGNED DRAWN APPROVED JOB NUMBER REVISIONS DATE Landscape Architects Land Planners Environmental Consultants www.cotleurhearing.com 1934 Commerce Lane Suite 1 Jupiter, Florida 33458 561.747.6336 · Fax 747.1377 Lic# LC-C000239 LAH/TJB TJB LAH 2 23-0312 St . L u c i e C o u n t y , F l o r i d a WA L T O N R A N C H - M E R I T A G E H O M E S 03-22-24 06-17-24 SITE DATALEGAL DESCRIPTION KEY MAP MCQUILLEN RD TILTON RD DYER RD LE N N A R D R D SI L V E R O A K D R SH A N A S T R A I L S U S H W Y 1 SITE SAVANNAHS PRESERVE STATE PARK LEGEND LB LANDSCAPE BUFFER ROW RIGHT OF WAY REC OPEN SPACE/RECREATION SW SIDEWALK DE DRAINAGE EASEMENT UE UTILITY EASEMENT TRAFFIC STATEMENTDRAINAGE STATEMENTENVIRONMENTAL STATEMENT ENVIRONMENTAL: AQUATIC RESEARCH MONITORING, EQUIPMENT & DEPLOYMENT, LLC. PO BOX 1421 STUART, FL 34995-1421 772.626.9005 CIVIL ENGINEER: KIMLEY-HORN & ASSOCIATES, INC. 445 24 THE STREET, SUITE 200 VERO BEACH, FL 32960 772.794.4099 OWNER: MERITAGE HOMES OF FLORIDA INC. 1400 CENTREPARK BLVD., SUITE 1000 WEST PALM BEACH, FL 33401 561.983.0675 LANDSCAPE ARCHITECT/PLANNER: COTLEUR & HEARING, INC. 1934 COMMERCE LANE, SUITE 1 JUPITER, FL 33458 561.747.6336 PROJECT TEAM SURVEYOR: CAULFIELD & WHEELER, INC. 7900 GLADES ROAD, SUITE 100 BOCA RATON, FLORIDA 33433 561.392.1991 TRAFFIC ENGINEER: PINDER TROUTMAN CONSULTING, INC. 601 HERITAGE DRIVE, SUITE 493 JUPITER, FL 33458 561.296.9698 THE ITE TRIP GENERATION MANUAL, 11TH EDITION, LAND USE CODE 210 (RESIDENTIAL SINGLE FAMILY) WAS USED TO DETERMINE EXPECTED DAILY AND PEAK HOUR TRIPS FOR THE PROPOSED PROJECT. TRIP GENERATION AM PEAK HOUR PM PEAK HOUR LAND USE INTENSITY DAILY IN OUT TOTAL IN OUT TOTAL RESIDENTIAL 141 DUS 1,384 27 75 102 86 51 137 DEVELOPMENT OF THE PROPOSED WALTON RANCH COMMUNITY HAS BEEN DESIGNED TO INCORPORATE THE SITE'S NATURAL FEATURES TO THE GREATEST POSSIBLE EXTENTS WHILE MAINTAINING REASONABLE USABILITY OF THE SITE. THIS INCLUDES MINIMAL WETLAND IMPACTS WITH A MITIGATION PLAN THAT INCORPORATES WETLAND ENHANCEMENT AND PERPETUAL PRESERVATION INTO THE PROPOSED COMMUNITY DESIGN. NO LISTED SPECIES NESTING, DENNING NOR ROOSTING IS OCCURRING ON THE SUBJECT PROPERTY THEREBY NO LISTED SPECIES IMPACTS ARE PROPOSED NOR ANTICIPATED FROM CONSTRUCTION OF THE PROJECT. LOTS 1, 2, 3, 15 AND 16, BLOCK 2, PLAT NO. 1 SAINT LUCIE GARDENS SECTION 23, TOWNSHIP 36 SOUTH, RANGE 40 EAST, ACCORDING TO THE MAP OR PLAT THEREOF, RECORDED IN PLAT BOOK 1, PAGE(S) 35, PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. CONTAINING 45.733 ACRES MORE OR LESS. SAID LANDS SITUATE IN ST. LUCIE COUNTY, FLORIDA. SUBJECT TO EASEMENTS, RESTRICTIONS, RESERVATIONS, COVENANTS, AND RIGHTS-OF-WAY OF RECORD. THE PROPOSED DRAINAGE SYSTEM CONSISTS OF A SERIES OF CATCH BASINS, MANHOLES, AND STORMWATER DRAINAGE PIPING WHICH WILL DRAIN TO THREE (3) ONSITE WET DETENTION AREA. THE ONSITE WET DETENTION AREAS SHALL PROVIDE TREATMENT AND ATTENUATION PRIOR TO DISCHARGING OFFSITE. THE PROJECT SITE IS LOCATED WITHIN A FEMA FLOOD ZONE X AS SHOWN ON THE FEMA FIRM MAP NUMBERS 12111C0283J AND 12111C0279K, EFFECTIVE DATES FEBRUARY 16, 2012 AND FEBRUARY 19, 2020, RESPECTIVELY. Page 161 of 428 50' R/W 5'10' 10'10' R/ W L I N E CONC. SW R/ W L I N E RO A D 2%2% 2% MAX.2% APPROXIMATE FINISHED GRADEAPPROXIMATE FINISHED GRADE VALLEY GUTTER (TYP.) VALLEY GUTTER (TYP.) ASPHALT PAVEMENT COQUINA BASE 27'23' 5' CONC. SW 2% 10' UTILITY EASEMENT (U.E.) 2% MAX. 10' UTILITY EASEMENT (U.E.) SUBGRADE WM F.P.L./ BELLSOUTH/ CABLE GRAVITY SANITARY SEWER NOTE: FIBEROPTICS WILL BE LOCATED IN 10' UE IF FM IS REQUIRED. FRONT LOADED DRIVEWAYS REQUIRED TO BE 22' IN LENGTH CL 2' 2' MIN 2'2' 5' MINIMUM DISTANCE TYPICAL LOCATION OF WATER METER OR SEWER CLEANOUT TYPICAL LOCATION OF WATER METER OR SEWER CLEANOUT F.P.L./ BELLSOUTH/ CABLE 2' MIN 6' 2'10' MIN. CL 50' TYP. 5' TYP. SETBACK 110' MIN. LOT LINE 3' ACCESORY SB 0' WHEN ADJACENT TO LAKE 10' REAR SB 60' MIN. 15' ROAD SETBACK BUILDABLE AREA 110' MIN. LOT LINE 3' ACCESORY SB 0' WHEN ADJACENT TO LAKE 10' REAR SB BUILDABLE AREA INTERNAL LOT CORNER LOT 2' ACCESORY SB 22' FRONT SB 22' FRONT SB 5' TYP. SETBACK 5' TYP. SETBACK 50' MIN. 10'10' 5' TYP. SETBACK110' MIN. 22' DRIVE MIN LOT LINE 3' ACCESORY SB 0' WHEN ADJACENT TO LAKE 10' REAR SB 2' ACCESORY SB 10' UE D CURB 8" 6" 6" BASE 18" 2" RAD. PAVEMENT SIDEWALK DETAIL NTS 3,000 PSI CONCRETE SUBGRADE COMPACTED TO 98% MAX. DRY DENSITY PER AASHTO T-99 METHOD TYPE: COLOR: FINISH: LANDSCAPE FORMS FPG BIKE RACK DARK GREY/SILVER POWDER COAT ALUMINUM CASTING ALUMINUM CASTING 2' - 7" 6" 2' - 6" 3-1/2" 1-1/4" BIKE RACK DETAIL NTS 4" (6" AT DRIVEWAYS) PUD DETAILS F CURB 1/4" MAX. 6" 12" 6" R2" R3" 8"16"24"3000 PSI CONCRETE ASPHALT 6" M I N . 7 12" BENCH DETAIL NTS TYPICAL GUEST AND HANDICAP PARKING DETAIL NTS HANDICAP RAMP DETAIL NTS SURFACE MOUNT OPTION: (4) 1/4" THICK ANCHOR TABS WITH Ø1/2"HOLE FOR ANCHORING. NON-CORROSIVE ANCHORING HARDWARE SUPPLIED BY OTHERS. EMBEDDED OPTION: INCLUDES (4) 10mm x 120mm THREADED RODS Drawing: AX203-01Dimensions are in inches [mm]CONFIDENTIAL DRAWING INFORMATION CONTAINED HEREIN IS THE PROPERTY OF LANDSCAPE FORMS, INC. Date: 6/18/2014 www.landscapeforms.com Ph: 800.521.2546 BACKED BENCH, 69" LENGTH, NARROW WOOD SLATS SURFACE MOUNT DETAIL EMBEDDED DETAIL 1'-6 9/16" 1'-2 7/8" 10 11/16" 8 5/16" 10 7/8" 3'-5 5/16" 1'-1 11/16" 8 1/2"1 5/8" NARROW WOOD SLATS FREESTANDING GLIDE NTS HANDICAP SIGN DETAIL HANDICAPPED SYMBOL MUST BE WHITE IN COLOR *NOTE: PARKING STALL WIDTHS SHALL BE DIMENSIONS FROM CENTERLINE TO CENTERLINE OF PARKING STRIPES. THIS APPLIES TO HANDICAP STALLS AS WELL. 12" THESE SIGNS TYPICAL AT EACH ACCESSIBLE PARKING SPACE 18" FINE PER LOCAL CODE 12" 6" 78"-80" PARKING BY DISABLED PERMIT ONLY $ 250 FINE F.S. 318.18 FTP-22-06 18"FTP-21-06 NOTES: 1.THIS SIGN MAY ALSO BE WALL MOUNTED 2.SEE ALSO SIGN BASE DETAILS 6" WHITE 5'8'-6" 14" 12' 60° 6" BLUE 3'-6" WHITE DIAGONAL EQUALLY SPACED PER AISLE 14" 6" WHITE 6" BLUE 6" WHITE 6" BLUE 6" WHITE OVERALL SYMBOL HEIGHT MUST BE EITHER 3' OR 5' IN LENGTH 44" MIN.ACCESSIBLE BOLLARD SIGN IN 6" PIPE BOLLARD MONOLITHIC CONCRETE HANDICAP RAMP (3000 PSI) DETECTABLE WARNING SURFACE PER FDOT INDEX NO. 522-002 VA R I E S SE E S I T E P L A N 5' M I N . W I D T H 6" CONCRETE CURB MAX. SLOPE 1:12 PAVEMENT 2 % M A X . SL O P E 24" 6" WHITE 12" WHITE @ 3' O.C. 24" STOP BAR CROSSWALK AND STOP BAR DETAIL NTS 5'-0" SIDEWALK ADA RAMP (SEE BELOW DETAIL) 2' OH 12" 3/4"R. 6" 4" 6" 71 / 2 " SURFACE 1/ 4 " BASE 12" 24" VALLEY GUTTER TYPICAL 6' PVC FENCE DETAIL NTS NOTES: 1. DEVELOPER TO CHOOSE OPA4UE MATERIAL # TIME OF CONSTRUCTION 2. COLORS MAY VARY BASED UPON AVAILABILITY AND DEVELOPER PREFERENCES. by agreement in writing with the architect. Immediately report any discrepancies to the architect. SHEET COTLEUR & HEARING, INC. These drawings are the property of the architect and are not to be used for extensions or on other projects except OF DESIGNED DRAWN APPROVED JOB NUMBER REVISIONS DATE Landscape Architects Land Planners Environmental Consultants www.cotleurhearing.com 1934 Commerce Lane Suite 1 Jupiter, Florida 33458 561.747.6336 · Fax 747.1377 Lic# LC-C000239 LAH/TJB TJB LAH 2 23-0312 S t . L u c i e C o u n t y , F l o r i d a WA L T O N R A N C H - M E R I T A G E H O M E S 03-22-24 06-17-24 2 50' TYPICAL ROW 1" = 10' SCALE LOT TYPICAL NTS 50' LOT LOT AND DRIVEWAY TYPICAL 50' LOT DEVELOPMENT STANDARDS DATA DEVELOPMENT USES AND STANDARDS PRIMARY STRUCTURES: DEVELOPMENT STANDARD:SINGLE-FAMILY: MINIMUM LOT WIDTH:50' MINIMUM LOT DEPTH:115' MAXIMUM LOT DEPTH:NONE MAXIMUM BUILDING LOT COVERAGE:80% MAXIMUM IMPERVIOUS LOT COVERAGE:80% MINIMUM OPEN SPACE:20% MINIMUM FRONT SETBACK (FRONT LOADED):22' MINIMUM FRONT SETBACK (SIDE LOADED):10' MINIMUM SIDE SETBACK (INTERNAL LOT):5' (May be 0' on a zero-lot-line provided that minimum building separation of 10' is maintained between units, 15' building separation for Townhome and Apartments) MINIMUM SIDE SETBACK (CORNER LOT):15' (If adjacent to open space tract 15' in width or greater):5' MINIMUM REAR SETBACK (INTERNAL LOT):10' MINIMUM REAR SETBACK (CORNER LOT):10' DEVELOPMENT USES AND STANDARDS ACCESSORY STRUCTURES: DEVELOPMENT STANDARD:SINGLE-FAMILY: MINIMUM REAR SETBACK:3' (If adjacent to open space or common area tract 25' or wider):0' MINIMUM SIDE SETBACK (INTERNAL LOT):2' (2' from property line) MINIMUM SIDE SETBACK (CORNER LOT):15' *NOTE: IF ADJACENT TO AN OPEN SPACE TRACT 15' IN WIDTH OR GREATER, THE SIDE CORNER LOT SETBACK CAN BE REDUCED TO 5'. WHEN NOT ADJACENT TO AN OPEN SPACE TRACT, SIDE SETBACK SHALL BE A MINIMUM OF 10' ON STREET SIDE. 14 1/2 [370] 2 1/2 [61] 37 [937] 19 [484] 19 1/2 [497] 4 3/4 [123] HINGE LOCATION FOR LID. LID SHOWN DASHED IN OPEN POSITION. RECEPTACLE DETAIL NTS LIGHTING DETAIL NTS 16.4' Ø4 [102] Ø6 [152] Ø15 31/64 [393] 16' 14' A A 17 17 47/64 [450] TWIST-LOCK RECEPTACLE (PHOTO-EYE CONTROL PROVIDED BY OTHERS) 3 [76] 5 [127] 16 SECTION A-A COVER PLATE ACCESS HOLE NTS NTS NTS NTS Page 162 of 428 WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WMWMWMWMWMWMWMWMWM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FMFMFMFMFMFMFM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM 33 0 ' 66 0 ' 1320' 1320'8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 1LOT 2LOT 3LOT 4LOT 5LOT 6LOT 7LOT 8LOT 9LOT 10LOT 11LOT 12LOT 13LOT 14LOT 15LOT 16LOT 17LOT 18LOT 19LOT 20LOT 21LOT 22LOT 23LOT 24LOT 25LOT 26LOT 27LOT 28LOT 29LOT 30 LOT 31LOT 32LOT 33LOT 34LOT 35LOT 36LOT 37LOT 38LOT 39LOT 40LOT 41LOT 42LOT 43LOT 44LOT 45LOT 46LOT 47LOT48LOT49LOT50LOT51LOT52LOT53LOT 54LOT55LOT56LOT57LOT 58LOT59LOT60LOT61LOT62LOT63LOT64LOT65LOT66LOT 67LOT 68LOT 109LOT 110LOT 111LOT 112LOT 113LOT 114LOT 116LOT 117LOT 118LOT 119LOT 120LOT 121LOT 122LOT 127LOT 126LOT 125LOT 124LOT 123LOT 131LOT 130LOT 129LOT 128LOT 132LOT 133LOT 134LOT 135LOT 141LOT 140LOT 136LOT 137LOT 139LOT 138LOT 82LOT 83LOT84LOT85LOT86LOT 87LOT88LOT 89LOT90LOT 106LOT105LOT104LOT103LOT102LOT 101LOT100LOT 99LOT98LOT 91LOT 97LOT 92LOT 93LOT 94LOT 95LOT 96LOT 115LOT 69LOT 70LOT81LOT 80LOT 79LOT 71LOT 72LOT 73LOT 74LOT 78LOT 77LOT 76LOT 75LOT 1289' 61 0 ' 108LOT 107LOT EQUUS CIRCLE EQUUS CIRCLE EQUUS CIRCLE EQUUS CIRCLE EQ U U S C I R C L E EQ U U S C I R C L E ST A L L I O N L A N E TA N D E M T E R R A C E VA N N E R W A Y 351' LAKE 3 (2.38 AC TRACT) LAKE 2 (0.88 AC TRACT) LAKE 1 (1.23 AC TRACT) WETLAND (2.64 AC TRACT) WETLAND (.76 AC TRACT) BUFFER SILVER OAK DRIVE Mc Q U I L L E N R O A D TI L T O N R O A D 25' LB 40' LB 25' LB 25' LB CODE QTY BOTANICAL NAME COMMON NAME CONT CAL SIZE NATIVE REMARKS TREES AR 26 ACER RUBRUM RED MAPLE 45 GAL 2.5" CAL 12` HT Y FULL CANOPY, 5` CROWN SPREAD MIN. CE 200 CONOCARPUS ERECTUS GREEN BUTTONWOOD TREE 45 GAL 2.5" CAL 12` HT X 5` SPRD Y FULL CANOPY. SINGLE STRAIGHT TRUNK., 5' CROWN SPREAD CS 10 CORDIA SEBESTENA ORANGE GEIGER TREE 25 GAL 1" CAL 8`-10` HT Y FULL CANOPY DR 1 DELONIX REGIA ROYAL POINCIANA FG 2" CAL 10`-12` OA N SINGLE STRAIGHT TRUNK. FULL CANOPY. FLORIDA FANCY. PE*TM 51 PINUS ELLIOTTII `DENSA`SLASH PINE 45 GAL 5" DBH 12` HT X 5` SPRD Y FULL, LOW BRANCHED, COUNT TOWARD TREE MITIGATION CREDITS QV 234 QUERCUS VIRGINIANA LIVE OAK 65 GAL 3" DBH 12` HT X 5` SPRD Y SINGLE, STRAIGHT TRUNK. FULL CANOPY QV*TM 32 QUERCUS VIRGINIANA LIVE OAK SPECIMEN FG 5" DBH 20` HT X 10-12` SPRD Y FULL CANOPY, CHARACTER, SPECIMEN, COUNTED TOWARD TREE MITIGATION TDB 35 TAXODIUM DISTICHUM BALD CYPRESS 45 GAL 2.5" DBH 10`-12` OA Y FULL CANOPY, 5' CROWN SPREAD PALM TREES AA 10 ARCHONTOPHOENIX ALEXANDRAE KING ALEXANDER PALM NA NA 16` HT N FULL CANOPY, MATCHED, FF, MIN. 2' CT SP*TM 18 SABAL PALMETTO SABAL PALM NA NA 10`, 12` & 14` HTS.Y SLICK, STRAIGHT TRUNK. REGENERTAED, COUNTED TOWARD TREE MITIGATION CREDITS SS 25 SABAL PALMETTO CURVED CABBAGE PALM NA NA 10`, 16`, OR 22` CT, STGG Y STRONG, UNIQUE CURVES, SLICK TRUNKS SP 45 SABAL PALMETTO SABAL PALMETTO NA NA 8`,12`,18` CT, STGG Y SLICK, STRAIGHT TRUNK. REGENERTAED. CODE QTY BOTANICAL NAME COMMON NAME CONT SIZE SPACE NATIVE REMARKS SHRUBS AB1 8 AECHMEA CHANTINII 'BLACK'BLACK BROMELIAD 3 GAL 1`X1`1.5` OC N FULL & THICK AIB 1 ALCANTEREA IMPERIALIS IMPERIAL BROMELIAD 25 GAL 5` X 5`AS N FULL & THICK CIG 47 CHRYSOBALANUS ICACO GREEN COCOPLUM 7 GAL 3` X 3`3` OC Y FULL & THICK CI3 3,238 CHRYSOBALANUS ICACO 'RED TIP'RED TIP COCOPLUM 3 GAL 4` X 3`3.5` OC Y FULL & THICK CLG 108 CLUSIA GUTTIFERA SMALL-LEAF CLUSIA 7 GAL 3` X 3`3` OC N FULL & THICK CES7 150 CONOCARPUS ERECTUS `SERICEUS`SILVER BUTTONWOOD 7 GAL 3` X 3`3` OC Y FULL & THICK SR3 331 SERENOA REPENS `CINEREA`SILVER SAW PALMETTO 3 GAL 2.5` X 2.5`3` OC N FULL & THICK GROUND COVERS CIG2 103 CHRYSOBALANUS ICACO GREEN COCOPLUM 7 GAL 3` X 3`3` OC Y FULL & THICK CLN 40 CLUSIA ROSEA `NANA`DWARF CLUSIA 3 GAL 1.5` X 1.5`2` OC Y FULL & THICK CE3 170 CONOCARPUS ERECTUS GREEN BUTTONWOOD 3 GAL 2` X 2`2` OC Y FULL & THICK CES3 98 CONOCARPUS ERECTUS `SERICEUS`SILVER BUTTONWOOD 3 GAL 2` X 2`2` OC Y FULL & THICK FG 305 FICUS MACROPHYLLA `GREEN ISLAND`GREEN ISLAND FICUS 3 GAL 1.5` x 1.5`1.5` OC N FULL & THICK IVN 3,566 ILEX VOMITORIA 'NANA'DWARF YAUPON HOLLY 1 GAL 2` X 2`2` OC Y FULL & THICK IX 184 IXORA X `MAUI YELLOW`YELLOW MAUI IXORA 7 GAL 3` X 2`3` OC N FULL & THICK MUH 200 MUHLENBERGIA CAPILLARIS PINK MUHLY GRASS 3 GAL 2` X 2`2` OC N FULL &THICK SB2 8,910 SPARTINA BAKERI SAND CORD GRASS PLUG 2` X1`1` OC Y FULL & THICK TF3 525 TRIPSACUM FLORIDANA DWARF FAKAHATCHEE GRASS 3 GAL 2` X 2`2.5` OC Y FULL & THICK LITTORAL PLANTINGS L-1 4,512 LT-1 LITTORAL PLANTINGS MULTIPLE LITTORAL PLANTING PLUG NA 1.5` OC Y ELEOCHARIS CELLULOSA, PONTEDERIA CORDATA, SAGITARIA LATIFOLIA L-2 2,340 LT-2 LITTORAL PLANTINGS MULTIPLE LITTORAL PLANTING PLUG NA 1.5` OC Y THALIA GENICULATA L-3 4,235 LT-3 LITTORAL PLANTINGS MULTIPLE LITTORAL PLANTING PLUG NA 2.5` OC Y NYMPHAEA ODORATA, PANICUM HEMITOMON 1 50' Scale: 1" = 100' 0'100'300'200' North 400' PUD MASTER LANDSCAPE PLAN by agreement in writing with the architect. Immediately report any discrepancies to the architect. SHEET COTLEUR & HEARING, INC. These drawings are the property of the architect and are not to be used for extensions or on other projects except OF DESIGNED DRAWN APPROVED JOB NUMBER REVISIONS DATE Landscape Architects Land Planners Environmental Consultants www.cotleurhearing.com 1934 Commerce Lane Suite 1 Jupiter, Florida 33458 561.747.6336 · Fax 747.1377 Lic# LC-C000239 TJB TJB LAH 4 23-0312 St . L X c L e C o X Q t \ , F l o r L G a WA L T O N R A N C H - M E R I T A G E H O M E S 03-22-24 06-17-24 LANDSCAPE DATA LEGAL DESCRIPTION PARCEL 1 (NORTH): LOTS 1, 2 AND 3, BLOCK 2, PLAT NO. 1 SAINT LUCIE GARDENS SECTION 23, TOWNSHIP 36 SOUTH, RANGE 40 EAST, ACCORDING TO THE MAP OR PLAT THEREOF, RECORDED IN PLAT BOOK 1, PAGE(S) 35, PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. CONTAINING 27.664 ACRES MORE OR LESS. SAID LANDS SITUATE IN ST. LUCIE COUNTY, FLORIDA. SUBJECT TO EASEMENTS, RESTRICTIONS, RESERVATIONS, COVENANTS, AND RIGHTS-OF-WAY OF RECORD PARCEL 2 (SOUTH): LOTS 15 AND 16, BLOCK 2, SECTION 23, TOWNSHIP 36 SOUTH, RANGE 40 EAST, PLAT NO. 1, ST. LUCIE GARDENS BY THE INDIAN RIVER, AS RECORDED IN THAT CERTAIN PLAT RECORDED IN PLAT BOOK 1, PAGE 35, OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA; LESS ROAD THAT PART LYING IN RIGHT OF WAY, IF ANY. CONTAINING 18.069 ACRES MORE OR LESS. SAID LANDS SITUATE IN ST. LUCIE COUNTY, FLORIDA. KEY MAP MCQUILLEN RD TILTON RD DYER RD LE N N A R D R D SI L V E R O A K D R SH A N A S T R A I L S U S H W Y 1 SITE SAVANNAHS PRESERVE STATE PARK BUFFER QUANTITIES: * TREE COUNT DOES NOT INCLUDE ANY TREES BEING COUNTED TOWARDS LITTORAL OR VUA REQUIREMENTS NORTH BUFFER (885') REQUIREMENTS: 25' BUFFER, 30 NATIVE TREES, NATIVE HEDGE PROVIDED: 25' BUFFER, 32 CE, COCOPLUM HEDGE EAST BUFFER (2,687') REQUIREMENTS: 25' BUFFER, 90 NATIVE TREES, NATIVE HEDGE PROVIDED: 40' BUFFER, 96 CE, COCOPLUM HEDGE SOUTH BUFFER (506') REQUIREMENTS: 25' BUFFER, NATIVE SHADE TREES, NATIVE HEDGE PROVIDED: 25' BUFFER WHILE RETAINING EXISTING WETLAND VEGETATION WEST BUFFER (2,090') REQUIREMENTS: 25' BUFFER, 70 NATIVE TREES, NATIVE HEDGE PROVIDED: 24' BUFFER, 75 CE, COCOPLUM HEDGE VUA CALCULATIONS: *TREE COUNT DOES NOT INCLUDE ANY TREES BEING COUNTED TOWARDS LITTORAL OR BUFFER REQUIREMENTS 1 TREE PER 50 LINEAR FEET IN ISLAND ABUTTING ROW AND ROADWAY REQUIRED: 5,910 LF X 2 = 11,820 LF / 50 = 237 TREES PROVIDED: 232 QV, 2 QV1, 10 AA = 244 TREES 1 TREE PER VUA PARKING ISLAND REQUIRED: 3 TREES PROVIDED: 3 QV TREE MITIGATION: TOTAL SABAL PALMS TO BE MITIGATED FOR AND PLANTED AT 10' CLEAR TRUNK: 18 (LABELED SP*TM) TOTAL PINE TREES TO BE PLANTED AT 5" DBH FOR A 1:1.5 RATIO: 51 PINE TREES (LABELED PE*TM) TOTAL OAK TREES TO BE PLANTED AT 5" DBH FOR A 1:1.5 RATIO: 32 OAK TREES (LABELED QV*TM) 1.) ALL TREE SPECIES CLOSE TO INTERIOR PRIVATE DRIVES AND UNDERGROUND UTILITIES, WHEN NOT ABLE TO BE MAINTAINED AT A MINIMUM OF A 5' DISTANCE, SHALL BE INSTALLED WITH A ROOT BARRIER TO PREVENT INTERFERENCE WITH SUCH INFRASTRUCTURE. SPECIFIC ROOT BARRIER LOCATIONS WILL BE PROVIDED DURING SITE PLAN SUBMITTAL. 2.) ALL TREES PLACED WITHIN 10' OF DRAINAGE STRUCTURES OR PIPR SHALL BE INSTALLED WITH A ROOT BARRIER TO PROTECT THE DRAINAGE SYSTEM. SPECIFIC ROOT BARRIER LOCATIONS WILL BE PROVIDED AT SITE PLAN SUBMITTAL 3.) ALL TREE SPECIES AND THEIR RESPECTIVE LIMBS AND FOLIAGE THAT ENCROACH UPON THE LINE-OF-SIGHT TRIANGLES SHALL BE INSTALLED AND MAINTAINED AT OR ABOVE SIX (6) FEET ABOVE THE ROADWAY INTERSECTION ELEVATION TO PROVIDE UNOBSTRUCTED CROSS-VISIBILITY. 4.) LITTORAL AREAS ARE SHOWN FOR CONCEPTUAL QUANTITIES AND ARE SUBJECT TO CHANGE BASED ON ENGINEER CONSTRUCTION DRAWINGS. 5.) RECREATIONAL/ COMMON OPEN AREAS ARE TO BE DESIGNED IN FULL AT TIME OF SITE PLAN APPLICATION PLANT SCHEDULE LB LANDSCAPE BUFFER ROW RIGHT OF WAY REC OPEN SPACE/RECREATION SW SIDEWALK DE DRAINAGE EASEMENT UE UTILITY EASEMENT NOTES: LAKE LITTORAL PLANTINGS: 10 SF OF LITTORAL PLANTINGS PER EVERY 1 LF OF SHORELINE LAKE SHORE LENGTH REQUIRED LITTORAL PROVIDED LITTORAL LAKE 1: 896 LF 8,960 SF 9,771 SF LAKE 2: 743 LF 7,430 SF 7,557 SF LAKE 3:1,273 LF 12,730 SF 12,840 SF LAKE UPLAND TRANSITION ZONE PLANTINGS: * TREE COUNT DOES NOT INCLUDE ANY TREES BEING COUNTED TOWARDS LITTORAL OR VUA REQUIREMENTS MIN. 10' WIDE UPLAND TRANSITION ZONE 1 (25 GAL) TREE PER 900 SF OF UTZ BUFFER 1 (3 GAL) SHRUB PER 100 SF OF UTZ BUFFER 1 (9 GAL) GROUNDCOVER PER 9 SF OF UTZ BUFFER 1 BARE ROOT, LINER GRASS, OR HERBACEOUS PLANT PER 4 SF OF UTZ BUFFER LAKE 1 REQUIREMENTS: 9,271 SF OF UTZ BUFFER REQUIRED: 11 TREES, 93 SHRUBS, 1,030 GROUNDCOVERS, 2,318 BARE ROOTS PROVIDED: 26 TREES, 110 SHRUBS, 1,068 GROUNDCOVERS, 2,771 BARE ROOTS LAKE 2 REQUIREMENTS: 8,751 SF OF UTZ BUFFER REQUIRED: 10 TREES, 88 SHRUBS, 972 GROUNDCOVERS, 2,188 BARE ROOTS PROVIDED: 24 TREES, 90 SHRUBS, 1,030 GROUNDCOVERS, 2,281 BARE ROOTS LAKE 3 REQUIREMENTS: 13,039 SF OF UTZ BUFFER REQUIRED: 15 TREES, 131 SHRUBS, 1,449 GROUNDCOVERS, 3,260 BARE ROOTS PROVIDED: 26 TREES, 131 SHRUBS, 1,468 GROUNDCOVERS, 3,858 BARE ROOTS LEGEND EXISTING CANOPY TO REMAIN EXISTING PINES TO REMAIN EXISTING PALMS TO REMAIN Page 163 of 428 WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FMFMFMFMFMFMFMFMFMFMFMFMFM 33 0 ' 1320'8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 LOT 11 LOT 12LOT 13 LOT 14 LOT 15 LOT 116 LOT 117 LOT 118 LOT 119 LOT 120 LOT 121 LOT 122 LOT 127 LOT 126 LOT 125 LOT 124 LOT 123 LOT 131 LOT 130 LOT 129 LOT 128 LOT 132 LOT 133 LOT 134 LOT 135 LOT 141 LOT 140 LOT 136 LOT 137 LOT 139 LOT 138 LOT 1289' 61 0 ' EQUUS CIRCLE TA N D E M T E R R A C E VA N N E R W A Y 40 CE 190 CI3 11 CE 73 MUH CE3 85 85 CE3 73 MUH 912 SB2 388 IVN 758 SB2 269 IVN SB2 611 IVN 373 SP 21 AR 6 TDB 11SR3 90 L-1 397 L-2 332 L-3 268 343 L-1 266 L-3 321 L-2 343 L-3 253 L-2 336 L-1 CIG 14 647 CI3 L-3 485TDB 12SB2 2,771 AR 14 IVN 1,068 L-2 367 L-3 428 191 L-2 216 L-1 188 L-2 473 L-3 245 L-2 L-2 297 124 L-1 146 L-2 164 L-1 316 L-3 CES7 45 1 QV*TM 16 CIG 2 QV*TM 1 QV*TM QV*TM 1 QV*TM 2 67 CES3 IX 76 CIG2 25 AB1 2 CLN 40 FG 209 108 IX 20 CIG2 10 CS 10 AA 1 AIB CIG2 5819 QV QV 16 22 QV 15 QV CES3 31110 SR3 84 CES7 32 CEPE*TM 22 TF3 231 5 QV*TM 5 QV*TM 1 QV*TM LAKE 2 (0.88 AC TRACT) LAKE 1 (1.23 AC TRACT) WETLAND (2.64 AC TRACT) WETLAND (.76 AC TRACT) BUFFER TI L T O N R O A D 6 SP*TM 36 CLG 96 FG 2 25' Scale: 1" = 50' 0'50'150'100' North 200' LANDSCAPE PLAN by agreement in writing with the architect. Immediately report any discrepancies to the architect. SHEET COTLEUR & HEARING, INC. These drawings are the property of the architect and are not to be used for extensions or on other projects except OF DESIGNED DRAWN APPROVED JOB NUMBER REVISIONS DATE Landscape Architects Land Planners Environmental Consultants www.cotleurhearing.com 1934 Commerce Lane Suite 1 Jupiter, Florida 33458 561.747.6336 · Fax 747.1377 Lic# LC-C000239 TJB TJB LAH 4 23-0312 St . L X c L e C o X Q t \ , F l o r L G a WA L T O N R A N C H - M E R I T A G E H O M E S 03-22-24 06-17-24 KEY MAP MCQUILLEN RD TILTON RD DYER RD LE N N A R D R D SI L V E R O A K D R SH A N A S T R A I L S U S H W Y 1 THIS SHEET SAVANNAHS PRESERVE STATE PARK MA T C H L I N E - S E E S H E E T 3 Page 164 of 428 WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM 66 0 ' 1320' 1320' LOT 16 LOT 17 LOT 18 LOT 19 LOT 20 LOT 21 LOT 22 LOT 23LOT 24 LOT 25 LOT 26 LOT 27 LOT 28 LOT 29 LOT 30 LOT 31 LOT 32 LOT 33 LOT 34 LOT 35 LOT 36 LOT 37 LOT 38 LOT 39 LOT 40 LOT 41 LOT 42 LOT 43 LOT 44 LOT 45 LOT 46 LOT 47 LOT48LOT49 LOT 50 LOT51LOT52 LOT 53 LOT 54 LOT55 LOT 56 LOT 57 LOT 58 LOT59 LOT 60 LOT61 LOT 62 LOT 63 LOT64 LOT 65 LOT66 LOT 67 LOT 68 LOT 109 LOT 110 LOT 111 LOT 112 LOT 113 LOT 114 LOT 82 LOT 83 LOT 84 LOT 85 LOT86 LOT 87 LOT88 LOT 89 LOT 90 LOT 106 LOT105 LOT 104 LOT 103 LOT 102 LOT 101 LOT100 LOT 99 LOT 98 LOT 91 LOT 97 LOT 92 LOT 93 LOT 94 LOT 95 LOT 96 LOT 115 LOT 69 LOT 70 LOT 81 LOT 80 LOT 79 LOT 71 LOT 72 LOT 73 LOT 74 LOT 78 LOT 77 LOT 76 LOT 75 LOT 108 LOT 107 LOT EQUUS CIRCLE EQUUS CIRCLE EQUUS CIRCLE EQ U U S C I R C L E EQ U U S C I R C L E ST A L L I O N L A N E 42 CE CI3 510 CE 32 CI3 1,190 L-1 520 L-1 505 L-3 505 439 L-1 421 L-1 430 L-3 484 L-1 721 L-3 563 L-1 684 CI3 1,047 SB2 440 IVN SB2 390 IVN 157 98 SR3 SR3 15 SR3 18 SB2 375 IVN 153 SB2 342 IVN 116 164 IVN 470 SB2 164 IVN 470 SB2 764 SB2 274 IVN 6 AR 12 TDBSP 24 13 SS 6 SS 6 AB1 1 DR CI3 17 CIG 17 QV*TM 2 SS 6 MUH 33 21 MUH QV 11 QV 29 24 QV QV 17 QV 25 QV 21 35 QV QV*TM 7 1 QV*TM CE 43 PE*TM 29 TF3 294 CES7 21 4 QV*TM LAKE 3 (2.38 AC TRACT) SILVER OAK DRIVE Mc Q U I L L E N R O A D 6 SP*TM 36 CLG 6 SP*TM 36 CLG 3 25' Scale: 1" = 50' 0'50'150'100' North 200' LANDSCAPE PLAN by agreement in writing with the architect. Immediately report any discrepancies to the architect. SHEET COTLEUR & HEARING, INC. These drawings are the property of the architect and are not to be used for extensions or on other projects except OF DESIGNED DRAWN APPROVED JOB NUMBER REVISIONS DATE Landscape Architects Land Planners Environmental Consultants www.cotleurhearing.com 1934 Commerce Lane Suite 1 Jupiter, Florida 33458 561.747.6336 · Fax 747.1377 Lic# LC-C000239 TJB TJB LAH 4 23-0312 St . L X c L e C o X Q t \ , F l o r L G a WA L T O N R A N C H - M E R I T A G E H O M E S 03-22-24 06-17-24 KEY MAP MCQUILLEN RD TILTON RD DYER RD LE N N A R D R D SI L V E R O A K D R SH A N A S T R A I L S U S H W Y 1 SAVANNAHS PRESERVE STATE PARK MA T C H L I N E - S E E S H E E T 2 THIS SHEET Page 165 of 428 dwgmodels.com dwgmodels.com dwgmodels.com dwgmodels.com dwgmodels.com dwgmodels.comdwgmodels.com dwgmodels.com dwgmodels.com dwgmodels.com dwgmodels.com dwgmodels.com dwgmodels.com dwgmodels.com dwgmodels.com dwgmodels.comdwgmodels.com dwgmodels.com TYPE 1 LITTORAL PLANTINGS 5'24' 10' MIN. UPLAND TRANSITION ZONE 20' LME 4' MIN. TO PIPE 10' ACCESS UPLAND TRANSITION PLANTINGS 1:4 1:10 1:3 PROPERTY LINE OR LANDSCAPE BUFFER LITTORAL SHELF PLANTINGS WIDTH VARIES TYPE 2 LITTORAL PLANTINGS TYPE 3 LITTORAL PLANTINGS LITTORAL SHELF WIDTH VARIES 20' LME 10' MIN. UPLAND TRANSITION ZONE PLANTINGS SHALL BE CLUSTERED SO AS NOT TO DISTURB ACCESS ALONG THE LAKE LAKE LITTORAL SHELF WIDTH VARIES 10' MIN. UPLAND TRANSITION ZONE 20' LME UPLAND TRANSITION AREA LITTORAL AREA 1 LITTORAL AREA 2 LITTORAL AREA 3 NOTE: 10 SF OF LITTORAL / 1 LF OF LAKE EDGE UP TO 50% OF SHORELINE CLUSTER OF THREE (3) SABAL PALMS ONE (1) RED MAPLE CLUSTER OF THREE (3) BALD CYPRESS 30' BETWEEN LARGE TREES 25' BUFFER ON 2-3' BERM WITH WALL/FENCE 30' BETWEEN LARGE TREES HEDGE TO BE MIN. 4' TALL WITH A WALL/FENCE HEDGE TO BE MIN. 4' TALL WITH A WALL/FENCE ACCESS & IMPROVEMENTS; DE & UE TO BE DETERMINED AT TIME OF FINAL SITE PLAN 25' BUFFER 1'-3' BERM 1:4 1:4 2'-5' VARIES 6' PVC FENCE 10' CANOPY LAYER PROPERTY LINE OR ROW HEDGE ON EITHER SIDE OF WALL/FENCE LANDSCAPE DETAILS PLANTING DETAILS NTS TREE PROTECTION DETAIL SECTION VIEW ORANGE PLASTIC CONSTRUCTION FENCING STEEL BAR FINISHED GRADE FENCE LOCATIONS TO BE APPROVED IN FIELDTO DRIP LINE 4'-0" LARGE TREE PLANTING DETAIL NTS PLACE RUBBER HOSE ON WIRE AT ALL POINTS OF CONTACT WITH TREE PLACE 3 (DOUBLE STRANDS) 12 GAUGE GALVANIZEDGUY WIRE, SPACED EQUAL DISTANCE AROUND TREE ABOVE FIRST LATERAL BRANCH PLACE SAFETY FLAGS ON GUY WIRES TWIST WIRES TO ADJUST TENSION ON GUY WIRE REMOVE BURLAP FROM TOP 1/3 OF ROOTBALL IF APPLICABLE 3" MULCH FORM SAUCER WITH 4"-6" CONTINUOUS EARTHENRIM AROUND PLANTING HOLE 2"x4"x24" WOOD STAKE DRIVEN 3" BELOW GRADE PLANTING PIT DEPTH SHALL EQUAL DEPTH OF ROOTBALL PLUS 6" FOR SETTING LAYER OF COMPACTED STANDARD PLANTING MIXTURE. PLANTING PIT WIDTH SHALL BE TWICE THE DIAMETER OF ROOT BALL BACK FILL AROUND ROOT BALL WITH STANDARD PLANTING MIXTURE. ELIMINATE AIR POCKETS. PLANT TOP OF ROOT BALL SLIGHTLY HIGHER THAN FINISHED GRADE PLACE ROOT BALL AT BOTTOM OF PLANTING PIT ON4"-6" LAYER OF COMPACTED STANDARD PLANTINGMIXTURE. SHRUB/GROUNDCOVER PLANTING DETAIL NTS 3" MULCH FORM SAUCER WITH 3" CONTINUOUS EARTHEN RIM AROUND PLANTING HOLE PLANTING PIT DEPTH SHALL BE 4"-6" GREATER THAN ROOT BALL. PLANTING PIT WIDTH SHALL BE TWICE THE DIAMETER FOR ROOT BALLS 2' AND UNDER OR 2' LARGER IN DIAMETER FOR ROOT BALLS OVER 2'. BACK FILL AROUND ROOT BALL WITH STANDARD PLANTING MIX. ELIMINATE AIRPOCKETS. PLACE TOP OF ROOT BALL 2" ABOVE FINISHED GRADE PLACE ROOT BALL AT BOTTOM OF PLANTING PIT ON 4"-6" LAYER OF COMPACTED STANDARD PLANTING MIXTURE NTS ROOT BARRIER DETAIL SECTION VIEW FINISHED GRADE CURB OR SIDEWALK TOP OF ROOT BARRIER TO BE INSTALL 1/4" BELOW TOP OF CURB/SIDEWALK. CURB OR SIDEWALK 20 LF OF 19.5 INCH DEEP "BIO BARRIER" ROOTBARRIER INSTALLED IN ACCORDANCE WITHMANUFACTURER'S INSTRUCTIONS. ROOT BARRIER TO BE INSTALLED FLUSH WITH CURB OR SIDEWALK. 19.5" STAKING DETAIL NTS 2"x4" WOOD BRACE 2"x4" WOOD STAKE WITH BOARDS POSITIONED FACETO FACE, NAIL BRACE SECURELYTO WOOD STAKE BELOW FINISHEDGRADE EXISTING SOIL NTS ROOT BARRIER DETAIL PLAN VIEW 20 LF OF 19-24 INCH DEEP "DEEP ROOT" ROOT BARRIER INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.ROOT BARRIER TO BE INSTALLED FLUSH WITH CURB OR SIDEWALK. SIDEWALK CURB 10'10' 20' ROOT BARRIER 10'10' 20'ROOT BARRIER ORANGE PLASTICCONSTRUCTION FENCING STEEL BAR TO DRIP LINE NTS TREE PROTECTION DETAIL PLAN VIEW FINISHEDGRADE TRUNK IN GROUND DIRECTION OF CURVED TRUNK PALM CANOPY HEAD 3' - 5' PALM HEADS SHALL BESET STRAIGHT, NOT AT ANANGLE TO THE GROUND 3' - 5' EITHER 'C' OR 'S' CURVESARE ACCEPTABLE UNLESSOTHERWISE NOTED GENTLE CURVE BETWEEN3' AND 5'. EXTREME CURVESWILL NOT BE ACCEPTEDUNLESS OTHERWISE NOTED PLAN VIEW 'C''S' STANDARDSWING REVERSESWING 10'HT 20'HT 26'HT NO ABRUPT TRUNK CONSTRICTIONS SABAL PALMS TO BE SLICK TRUNK (UNLESSOTHERWISE NOTED) 5 - 2"x4"x18" WOOD BATTENS OVER 5 LAYERSOF BURLAP. DO NOT NAIL BATTENS TO PALM.HEIGHT OF BATTENS SHALL BE LOCATED INRELATION TO THE HEIGHT OF THE PALM FORADEQUATE BRACING 2 STEEL BANDS MINIMUM 3 - 2"x4" WOOD BRACES SHALL BETOE NAILED TO WOOD BATTENS PLANT ROOT BALL SLIGHTLY ABOVE FINISHEDGRADE 3" MULCH FORM SAUCER WITH 4"-6" CONTINUOUSEARTHEN RIM AROUND PLANTING HOLE 2"x4"x24" WOOD STAKE REMAINING 3"ABOVE GRADE PLACE ROOT BALL AT BOTTOM OF PLANTING PIT ONUNDISTURBED SUBGRADE TO PREVENT SETTLING MINIMUM ROOT BALL SIZE AS PER GRADES & STANDARDS. BACK FILL AROUND ROOT BALL WITH STANDARDPLANTING MIXTURE. JET IN WITH WATER HOSE TOELIMINATE AIR POCKETS. EXISTING SUBGRADE SAFETY FLAG DIAMETER OF THE HOLE SHALL BE TWICE THE BALLDIAMETER. FOR ROOT BALLS 2' AND GREATER, THEHOLE SHALL BE 2' LARGER THAN THE BALL DIAMETER. FOR REGENERATED PALMS, ROOT PRUNEMINIMUM 8 WEEKS, MAXIMUM 12 WEEKS SKIRT SHALL BE NEAT AND MATCHED ON ALL PALMS SABAL PALM PLANTING DETAIL CLEAR TRUNK (CT)HEIGHT VARIES FINISHED GRADE NTS SABAL PALMS TO BE SLICK TRUNK (UNLESSOTHERWISE NOTED) 5 - 2"x4"x18" WOOD BATTENS OVER 5 LAYERSOF BURLAP. DO NOT NAIL BATTENS TO PALM.HEIGHT OF BATTENS SHALL BE LOCATED INRELATION TO THE HEIGHT OF THE PALM FORADEQUATE BRACING 2 STEEL BANDS MINIMUM 3 - 2"x4" WOOD BRACES SHALL BETOE NAILED TO WOOD BATTENS PLANT ROOT BALL SLIGHTLY ABOVE FINISHEDGRADE 3" MULCH FORM SAUCER WITH 4"-6" CONTINUOUSEARTHEN RIM AROUND PLANTING HOLE 2"x4"x24" WOOD STAKE REMAINING 3"ABOVE GRADE PLACE ROOT BALL AT BOTTOM OF PLANTING PIT ONUNDISTURBED SUBGRADE TO PREVENT SETTLING MINIMUM ROOT BALL SIZE AS PER GRADES & STANDARDS. BACK FILL AROUND ROOT BALL WITH STANDARDPLANTING MIXTURE. JET IN WITH WATER HOSE TOELIMINATE AIR POCKETS. EXISTING SUBGRADE SAFETY FLAG DIAMETER OF THE HOLE SHALL BE TWICE THE BALLDIAMETER. FOR ROOT BALLS 2' AND GREATER, THEHOLE SHALL BE 2' LARGER THAN THE BALL DIAMETER. FOR REGENERATED PALMS, ROOT PRUNEMINIMUM 8 WEEKS, MAXIMUM 12 WEEKS CURVED PALM TRUNK DETAIL NTS TYPICAL LAKE LITTORAL TYPICAL LITTORAL AND UPLAND SECTION TYPICAL UPLAND TRANSITION ZONE 4 by agreement in writing with the architect. Immediately report any discrepancies to the architect. SHEET COTLEUR & HEARING, INC. These drawings are the property of the architect and are not to be used for extensions or on other projects except OF DESIGNED DRAWN APPROVED JOB NUMBER REVISIONS DATE Landscape Architects Land Planners Environmental Consultants www.cotleurhearing.com 1934 Commerce Lane Suite 1 Jupiter, Florida 33458 561.747.6336 · Fax 747.1377 Lic# LC-C000239 TJB TJB LAH 4 23-0312 S t . L X c L e C o X Q t \ , F l o r L G a WA L T O N R A N C H - M E R I T A G E H O M E S 03-22-24 06-17-24 LANDSCAPE NOTES LANDSCAPE SPECIFICATIONS ALL PLANT MATERIAL SHALL BE FLORIDA NUMBER 1 OR BETTER AS DEFINED BY THE DIVISION OF PLANT INDUSTRY 'FLORIDA GRADES AND STANDARDS' LATEST EDITION. ALL LANDSCAPE SHALL CONFORM TO THE REQUIREMENTS OF ST. LUCIE COUNTY LAND DEVELOPMENT REGULATIONS. ST. LUCIE COUNTY LANDSCAPE CODE (LDRs) SHALL GOVERN IN THE EVENT OF A CONFLICT. VEGETATION REMOVAL PERMITS ARE REQUIRED PRIOR TO REMOVING, CLEARING OR STRIPPING ANY VEGETATION FROM THE PROPERTY. AT THE TIME OF BUILDING PERMIT, THE APPLICANT SHALL EXECUTE HOLD HARMLESS AGREEMENTS WITH ALL APPLICABLE UTILITIES FOR LANDSCAPING WITHIN UTILITY EASEMENTS. THE LANDSCAPE CONTRACTOR SHALL NOT MAKE ANY SUBSTITUTIONS AND/ OR CHANGES WITHOUT THE AUTHORIZATION OF ST. LUCIE COUNTY, THE OWNER AND THE LANDSCAPE ARCHITECT. THE LANDSCAPE CONTRACTOR SHALL REVIEW THE PROJECT DRAINAGE AND UTILITY PLANS PRIOR TO CONSTRUCTION AND AVOID ALL CONFLICTS. THE LANDSCAPE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES PRIOR TO COMMENCING WORK. THE LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PERMITS. THE CONTRACTOR SHALL COORDINATE THE PLANTING AND TRIMMING OF STREET TREES TO ENSURE FULL VISIBILITY TO TRAFFIC CONTROL AND SAFETY SIGNAGE TREES SHALL BE POSITIONED TO AVOID CONFLICTS WITH SIGNAGE AND SITE LIGHTING. LARGER TREES WILL BE PROVIDED AT INTERSECTIONS WHERE DEEMED NECESSARY. ALL VEGETATION SHALL BE SELECTED AND POSITIONED SO THAT IT DOES NOT PRESENT OBSTRUCTIONS TO THE LINE OF SIGHT AT INTERSECTIONS PURSUANT TO SECTION 27-1262(a)(9)(c) OF ST. LUCIE COUNTY CODE. ALL ABOVE GROUND UTILITIES I.E. TRANSFORMERS, SWITCH BOXES, AC CONDENSERS AND ALIKE SHALL BE FULLY SCREENED FROM VIEW ON THREE SIDES WITH LANDSCAPING. THE LANDSCAPING SHALL TO THE TALLEST POINT OF SAID EQUIPMENT AT TIME OF PLANTING. ALL TREES SHALL BE LOCATED WITHIN A MULCH PLANTING BED WITH A MINIMUM OF TWO (2) FEET OF CLEARANCE TO THE EDGE OF THE BED. SOD AND IRRIGATION SHALL BE INSTALLED IN ANY ADJACENT RIGHT OF WAY BETWEEN THE SIDEWALK AND THE CURB. ALL SOD SHALL BE STENOTAPHRUM SECONDATUS FLORITAM-PALMETTO (ST. AUGUSTINE SOD). TREES WITHIN PLANTING ISLANDS LESS THAN FIVE (5) FEET IN WIDTH SHALL BE LOCATED TO AVOID CONFLICTS WITH THE OVERHANG OF VEHICLES. TYPE D RAISED CONCRETE CURBING SHALL BE PROVIDED AROUND ALL PLANTING ISLANDS WITHIN VEHICULAR USE AREAS. TREES AT ENTRANCE WAYS AND WITHIN SIGHT TRIANGLES SHALL BE TRIMMED IN SUCH A FASHION TO MINIMIZE SITE VISIBILITY CONFLICTS. CLEAR VISIBILITY SHALL BE MAINTAINED BETWEEN 30 INCHES AND 7 FEET. TEN FOOT BY THIRTY FOOT SIGHT VISIBILITY TRIANGLES SHALL BE PROVIDED AT THE INTERSECTIONS WITH THE PUBLIC RIGHT OF WAY. IN ADDITION ALL LANDSCAPING SHALL CONFORM TO THE REQUIREMENTS OF FDOT INDEX 546. EARTH BERMS SHALL NOT EXCEED A 3:1 SLOPE 4:1 SLOPES OR GREATER ARE PREFERABLE. ALL TREES PLANTED UNDER OR ADJACENT TO FPL POWER LINES WILL COMPLY WITH THE FPL RIGHT TREE IN THE RIGHT PLACE GUIDELINES (REV 5/95) PERIMETER TREES AT THE TIME OF PLANTING SHALL BE SPACED IN A WAY THAT COMPLEMENTS THE SPACING OF ANY EXISTING TREES ON ADJACENT DEVELOPED AREAS. ALL LANDSCAPE ISLANDS AND BEDS SHALL BE FREE FROM SHELL ROCK AND CONSTRUCTION DEBRIS, EXCAVATED TO A DEPTH OF 30 INCHES OR TO CLEAN NATIVE SOILS AND FILLED WITH THE SPECIFIED BACKFILL MIXTURE. ALL LANDSCAPE ISLANDS SHALL INCORPORATE THE INSTALLATION OF MOUNDING OF NATIVE SOILS A MINIMUM OF SIX INCHES (6") ABOVE THE TOP OF CURB. 19.5" 'BIO BARRIER' ROOT BARRIER SHALL BE PROVIDED FOR SHADE TREES PLANTED WITHIN SIX (6') FEET OF PUBLIC CURBS, SIDEWALKS OR PUBLIC RIGHT OF WAYS. ALL ROOT BARRIER SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURES RECOMMENDATIONS. THE TOTAL LENGTH OF THE ROOT BARRIERS SHALL BE 20' ADJACENT TO THE SIDEWALK AND 20' ADJACENT TO THE CURB. ALL AREAS SHALL BE FULLY IRRIGATED BY AUTOMATIC MEANS IN ACCORDANCE WITH THE REQUIREMENTS OF ST. LUCIE COUNTY . THE IRRIGATION WATER SOURCE SHALL BE WELL WATER FOR COMMON AREAS AND POTABLE WATER AROUND THE BUILDING FOUNDATION. CATCH BASINS AND DRAINAGE SHALL NOT BE LOCATED WITH IN REQUIRED PERIMETER BUFFERS OR PRESERVE AREAS. THE IRRIGATION SYSTEM SHALL BE DESIGNED TO PROVIDE 100% OVERLAP COVERAGE TO ALL LANDSCAPE AND SOD AREAS. THE IRRIGATION SYSTEM SHALL BE EQUIPPED WITH A RAIN SENSOR/CUT OFF SWITCH IN ACCORDANCE WITH STATE AND LOCAL REQUIREMENTS. EXISTING TREES AND VEGETATION TO REMAIN SHALL BE STAKED AND BARRICADED PRIOR TO ANY LAND CLEARING. TREES TO BE RELOCATED SHALL BE ROOT PRUNED AND PROTECTED DURING CONSTRUCTION. ALL TREES PROPOSED TO BE PRESERVED ON SITE SHALL BE PROTECTED IN ACCORDANCE WITH THE PROCEDURES OUTLINED IN DIVISION IV., VEGETATION REMOVAL REQUIREMENTS IN THE ST. LUCIE COUNTY CODE PRIOR TO THE ISSUANCE OF A C.O. ANY AREA DESIGNATED WITH EXISTING VEGETATION TO REMAIN THAT IS DISTURBED DURING CONSTRUCTION WILL BE RESTORED WITH NATIVE PLANTINGS. EXISTING TREES PRESERVED OR RELOCATED ON SITE SHALL BE PRUNED ACCORDING TO ANSI A300 STANDARDS OR BY AN ISA CERTIFIED ARBORIST. ALL EXISTING LANDSCAPING AND TREES TO REMAIN SHALL BE BARRICADED WITH ORANGE CONSTRUCTION BARRICADE. THE BARRICADE SHALL BE INSTALLED AT THE DRIP LINE OF THE TREE/PALM OR AT THE EDGE OF THE SHRUB MASS. BARRICADES SHALL REMAIN IN PLACE THROUGHOUT THE DURATION OF CONSTRUCTION. EXISTING, SUITABLE NATIVE VEGETATION LOCATED WITHIN THE PROPOSED DEVELOPMENT AREAS SHALL BE RELOCATED TO SUPPLEMENT THE LANDSCAPING. NATIVE VEGETATION SHALL BE RELOCATED BY TREE SPADE OR CRANE. PRIOR TO THE CLEARING OF THE SITE THE APPLICANT SHALL IDENTIFY ALL NATIVE VEGETATION TO BE RELOCATED. RELOCATION METHODOLOGY: EXISTING NATIVE VEGETATION DETERMINED TO BE SUITABLE FOR RELOCATION SHALL BE RELOCATED TO TARGET AREAS USING HYDROLOGIC TREE SPADES. THE SIZE OF SPADE SHALL VARY FROM 90" TO 45" DEPENDING ON THE SIZE AND TYPE OF VEGETATION TO BE MOVED. THE APPLICANT SHALL IDENTIFY PRIOR TO THE CLEARING OF THE SITE ALL EXISTING NATIVE VEGETATION TO BE RELOCATED. FOLLOWING RELOCATION, VEGETATION SHALL BE WATERED DAILY. 1. GENERAL LANDSCAPE REQUIREMENTS LANDSCAPE CONTRACT WORK INCLUDES, BUT IS NOT LIMITED TO, SOIL PREPARATION, FINE OR FINISH GRADING, FURNISHING AND INSTALLING PLANT MATERIAL, WATERING, STAKING, GUYING AND MULCHING. PLANT SIZE AND QUALITY TREES, PALMS, SHRUBS, GROUNDCOVERS:PLANT SPECIES AND SIZES SHALL CONFORM TO THOSE INDICATED ON THE DRAWINGS, NOMENCLATURE SHALL CONFORM TO STANDARD PLANT NAMES, 1942 EDITION. ALL NURSERY STOCK SHALL BE IN ACCORDANCE WITH GRADES AND STANDARDS FOR NURSERY PLANTS PARTS I & II, LATEST EDITION PUBLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES, UNLESS SPECIFIED OTHERWISE. ALL PLANTS SHALL BE FLORIDA GRADE NUMBER 1 OR BETTER AS DETERMINED BY THE FLORIDA DIVISION OF PLANT INDUSTRY. ALL CONTAINER GROWN MATERIAL SHALL BE HEALTHY, VIGOROUS, WELL-ROOTED PLANTS AND ESTABLISHED IN THE CONTAINER IN WHICH THEY ARE SOLD. THE PLANTS SHALL HAVE TOPS OF GOOD QUALITY AND BE IN A HEALTHY GROWING CONDITION. AN ESTABLISHED CONTAINER GROWN PLANT SHALL BE TRANSPLANTED INTO A CONTAINER AND GROWN IN THAT CONTAINER SUFFICIENTLY LONG ENOUGH FOR THE NEW FIBROUS ROOTS TO HAVEDEVELOPED SO THAT THE ROOT MASS WILL RETAIN ITS SHAPE AND HOLD TOGETHER WHEN REMOVED FROM THE CONTAINER. STANDARD PLANTING MIXTURE SHALL BE ONE (1) PART RECYCLED ORGANIC MATERIAL ADDED TO THREE (3) PARTS EXISTING NATIVE SOIL. REPLACEMENT SOIL SHALL BE USED AS SPECIFIED TO REPLACE EXISTING SOILS THAT ARE DETERMINED BY THE LANDSCAPE ARCHITECT TO BE UNSUITABLE FOR PLANTING, IE. ROAD BASE, PAVEMENT, ETC.REPLACEMENT SOIL MIX SHALL CONTAIN 60% SAND AND 40% MUCK. SAND SHALL BE 100% CLEAN NATIVE SAND SCREENED TO 1/4" AND MUCK SHALL BE 100% CLEAN ORGANIC NATIVE MUCK SCREENED TO 1/2". ALL SOIL SHALL BE MIXED PRIOR TO DELIVERY ON SITE. MULCH SHALL BE SHREDDED EUCALYPTUS OR GRADE "A" RECYCLED. THE USE OF CYPRESS MULCH IS DISCOURAGED ON ALL RESIDENTIAL PROJECTS AND LANDSCAPE AREAS. ALL MULCH IS TO BE APPLIED TOA DEPTH OF 3", EXCEPT AS OTHERWISE NOTED. FERTILIZER IN BACKFILL MIXTURE FOR ALL PLANTS SHALL CONSIST OF MILORGANITE ACTIVATED SLUDGE MIXED WITH THE BACKFILL AT A RATE OF NOT LESS THAN 50 LBS. PER CUBIC YARD. FERTILIZER FOR TREES AND SHRUBS MAY BE TABLET FORM OR GRANULAR. GRANULAR FERTILIZER SHALL BE UNIFORM IN COMPOSITION, DRY AND FREE-FLOWING. THIS FERTILIZER SHALL BE DELIVERED TO THE SITE IN THE ORIGINAL UNOPENED BAGS, EACH BEARING THE MANUFACTURER'S STATEMENT OF ANALYSIS, AND SHALL MEET THE FOLLOWING REQUIREMENTS: 16% NITROGEN, 7% PHOSPHORUS, 12% POTASSIUM, PLUS IRON. TABLET FERTILIZER (AGRIFORM OR EQUAL) IN 21 GRAM SIZE SHALL MEET THE FOLLOWING REQUIREMENTS: 20% NITROGEN, 10% PHOSPHORUS AND 5% POTASSIUM. FERTILIZER WILL BE APPLIED AT THE FOLLOWING RATES: PLANT SIZE 16-7-12 AGRIFORM TABLETS (21 GRAM) 1 GAL. 1/4 LB. 1 3 GAL. 1/3 LB. 37-15 GAL. 1/2 LB. 61"-6" CALIPER 2 LBS./1" CALIPER 2 PER 1" CALIPER 6" AND LARGER 3 LBS./1" CALIPER 2 PER 1" CALIPER "FLORIDA EAST COAST PALM SPECIAL" SHALL BE APPLIED TO ALL PALMS AT INSTALLATION AT A RATE OF ½ LB. PER INCH OF TRUNK UNLESS OTHERWISE SPECIFIED. FIELD GROWN TREES AND PALMS PREVIOUSLY ROOT PRUNED SHALL OBTAIN A ROOT BALL WITH SUFFICIENT ROOTS FOR CONTINUED GROWTH WITHOUT RESULTING SHOCK. CONTRACTOR SHALL NOT MARK OR SCAR TRUNK IN ANY FASHION. PLANTS SHALL BE WATERED AS NECESSARY OR WITHIN 24 HOURS AFTER NOTIFICATION BY THE LANDSCAPE ARCHITECT. THE LOCATIONS OF PLANTS, AS SHOWN IN THESE PLANS, ARE APPROXIMATE. THE FINAL LOCATIONS MAY BE ADJUSTED TO ACCOMMODATE UNFORESEEN FIELD CONDITIONS. MAJOR ADJUSTMENTS TO THELAYOUT ARE TO BE APPROVED BY THE LANDSCAPE ARCHITECT. ALL PLASTIC FABRIC SHALL BE REMOVED FROM PLANT MATERIAL AT TIME OF INSTALLATION. ALL TREES MUST BE STAKED AS SHOWN ON THE PLANTING DETAILS WITHIN 24 HOURS OF PLANTING. STAKES TO REMAIN FOR A MINIMUM OF 9 MONTHS, BUT NO LONGER THAN 18 MONTHS. CONTRACTOR IS RESPONSIBLE FOR MAINTENANCE AND REMOVAL OF THE STAKES. ALL TREES MUST BE PRUNED AS PER LANDSCAPE ARCHITECT'S DIRECTION. ALL SHRUBS, TREES AND GROUND COVER WILL HAVE IMPROVED SOIL AS PER PLANTING SOIL NOTES. THE SOILS SHALL BE PLACED IN THE HOLE DURING PLANTING. TOP DRESSING ONLY IS NOT ACCEPTABLE. DO NOT ALLOW AIR POCKETS TO FORM WHEN BACKFILLING. ALL TREES SHALL BE SPIKED IN UTILIZING WATER AND A TREE BAR. THE LANDSCAPE CONTRACTOR SHALL WATER, MULCH, WEED, PRUNE, AND OTHERWISE MAINTAIN ALL PLANTS, INCLUDING SOD, UNTIL COMPLETION OF CONTRACT OR ACCEPTANCE BY LANDSCAPE ARCHITECT. SETTLED PLANTS SHALL BE RESET TO PROPER GRADE, PLANTING SAUCERS RESTORED, AND DEFECTIVE WORK CORRECTED. THE LANDSCAPE CONTRACTOR SHALL AT ALL TIMES KEEP THE PREMISES FREE FROM ACCUMULATION OF WASTE MATERIALS OR DEBRIS CAUSED BY HIS CREWS DURING THE PERFORMANCE OF THE WORK. UPON COMPLETION OF THE WORK, THE CONTRACTOR SHALL PROMPTLY REMOVE ALL WASTE MATERIALS, DEBRIS, UNUSED PLANT MATERIAL, EMPTY PLANT CONTAINERS AND ALL EQUIPMENT FROM THE PROJECT SITE. UPON COMPLETION OF THE WORK, THE LANDSCAPE CONTRACTOR SHALL NOTIFY THE LANDSCAPE ARCHITECT AND REQUEST A FINAL INSPECTION. ANY ITEMS THAT ARE JUDGED INCOMPLETE OR UNACCEPTABLE BY THE LANDSCAPE ARCHITECT OR OWNER'S REPRESENTATIVE SHALL BE CORRECTED BY THE LANDSCAPE CONTRACTOR WITHIN 14 DAYS. ALL LABOR AND MATERIAL FOR SOIL AMENDMENTS AND FERTILIZER THAT IS REQUIRED TO INSURE THE SUCCESSFUL ESTABLISHMENT AND SURVIVAL OF THE PROPOSED VEGETATION, AS WELL AS ALL THE COST FOR THE REMOVAL OF UNSUITABLE OR EXCESS BACKFILL MATERIAL, SHALL BE INCLUDED IN THE CONTRACTOR'S BID TO PERFORM THE WORK REPRESENTED IN THIS PLAN SET. 2. PLANTING TREES EXCAVATE PIT AS PER PLANTING DETAILS. BACKFILL AROUND BALL WITH STANDARD PLANTING MIXTURE AND SLIGHTLY COMPACT, WATER THOROUGHLY AS LAYERS ARE PLACED TO ELIMINATE VOIDS AND AIR POCKETS. BUILD A 6" HIGH BERM OF STANDARD PLANTING MIXTURE BEYOND EDGE OF EXCAVATION. APPLY 3" (AFTER SETTLEMENT) OF MULCH EXCEPT WITHIN 6" OF TRUNK. PRUNE TREE TO REMOVE DAMAGED BRANCHES, IMPROVE NATURAL SHAPE AND THIN OUT STRUCTURE. DO NOT REMOVE MORE THAN 15% OF BRANCHES. DO NOT PRUNE BACK TERMINAL LEADER. GUY AND STAKE TREE IN ACCORDANCE WIT THE STAKING DETAILS IMMEDIATELY AFTER PLANTING. 3. PLANTING SHRUBS LAYOUT SHRUBS TO CREATE A CONTINUOUS SMOOTH FRONT LINE AND FILL IN BEHIND. EXCAVATE PIT OR TRENCH TO 1-1/2 TIMES THE DIAMETER OF THE BALLS OR CONTAINERS OR 1'-0" WIDER THAN THE SPREAD OF ROOTS FOR POSITIONING AT PROPER HEIGHT. BACKFILL AROUND PLANTSWITH STANDARD PLANTING MIXTURE, COMPACTED TO ELIMINATE VOIDS AND AIR POCKETS. FORM GRADE SLIGHTLY DISHED AND BERMED AT EDGES OF EXCAVATION. APPLY 3" OF MULCH EXCEPT WITHIN 3" OF STEMS. PRUNE SHRUBS TO REMOVE DAMAGED BRANCHES, IMPROVE NATURAL SHAPE AND THIN OUT STRUCTURE. DO NOT REMOVE MORE THAN 15% OF BRANCHES. 4. PLANTING GROUND COVER LOOSEN SUBGRADE TO DEPTH OF 4" IN AREAS WHERE TOPSOIL HAS BEEN STRIPPED AND SPREAD SMOOTH. SPACE PLANTS AS OTHERWISE INDICATED. DIG HOLES LARGE ENOUGH TO ALLOW SPREADING OF ROOTS. COMPACT BACKFILLTO ELIMINATE VOIDS AND LEAVE GRADE SLIGHTLY DISHED AT EACH PLANT. WATER THOROUGHLY. APPLY 3" OF MULCH OVER ENTIRE PLANTING BED, LIFTING PLANT FOLIAGE ABOVE MULCH. DURING PERIODS OF HOT SUN AND/OR WIND AT TIME OF PLANTING, PROVIDE PROTECTIVE COVER FOR SEVERAL DAYS OR AS NEEDED. 5. PLANTING LAWNS SODDING: SOD TYPE SPECIFIED ON PLANT LIST SHALL BE MACHINE STRIPPED NOT MORE THAN 24 HOURS PRIOR TO LAYING. LOOSEN SUBGRADE TO DEPTH OF 4" AND GRADE WITH TOPSOIL EITHER PROVIDED ON SITE OR IMPORTED STANDARD PLANTING MIX TO FINISH DESIGN ELEVATIONS. ROLL PREPARED LAWN SURFACE.WATER THOROUGHLY, BUT DO NOT CREATE MUDDY SOIL CONDITION. FERTILIZE SOIL AT THE RATE OF APPROXIMATELY 10 LBS. PER 1,000 S.F. SPREAD FERTILIZER OVER THE AREA TO RECEIVE GRASS BY USING AN APPROVED DISTRIBUTION DEVICE CALIBRATED TO DISTRIBUTE THE APPROPRIATE QUANTITY. DO NOT FERTILIZE WHEN WIND VELOCITY EXCEEDS 15 M.P.H. THOROUGHLY MIX FERTILIZER INTO THE TOP 2" OF TOPSOIL. LAY SOD STRIPS WITH TIGHT JOINTS, DO NOT OVERLAP, STAGGER STRIPS TO OFFSET JOINTS IN ADJACENT COURSES. WORK SIFTED STANDARD PLANTING MIXTURE INTO MINOR CRACKS BETWEEN PIECES OF SOD AND REMOVE EXCESS SOIL DEPOSITS FROM SODDED AREAS. SOD ON SLOPES GREATER THAN 3:1 SHALL BE STAKED IN PLACE. ROLL OR STAMP LIGHTLY AND WATER THOROUGHLY WITH A FINE SPRAY IMMEDIATELY AFTER PLANTING. 6. MISCELLANEOUS LANDSCAPE WORK LANDSCAPE MAINTENANCE MAINTAIN LANDSCAPE WORK UNTIL FINAL ACCEPTANCE IS ISSUED BY THE OWNER'S REPRESENTATIVE. INCLUDE WATERING, WEEDING, CULTIVATING, RESTORATION OF GRADE, MOWING AND TRIMMING GRASS, PRUNING TREES AND SHRUBS, PROTECTION FROM INSECTS AND DISEASES, FERTILIZING AND SIMILAR OPERATIONS AS NEEDED TO INSURE NORMAL GROWTH AND GOOD HEALTH FOR LIVE PLANT MATERIAL. PLANT MATERIAL SUBSTITUTION NO SUBSTITUTION OF PLANT MATERIAL, TYPE OR SIZES WILL BE PERMITTED WITHOUT AUTHORIZATION FROM THE LANDSCAPE ARCHITECT. PLANTING BED PREPARATION ALL PLANTING BEDS SHALL BE PROPERLY PREPARED PRIOR TO THE COMMENCEMENT OF ANY PLANTING. PLANTING AREAS, INCLUDING LAWNS SHALL BE FREE OF ALL WEEDS AND NUISANCE VEGETATION. IF TORPEDO GRASS (PANICUM REPENS) IS PRESENT OR ENCOUNTERED DURING PLANTING, THE LANDSCAPE CONTRACTOR SHALL STOP ALL PLANTING UNTIL IT CAN BE DEMONSTRATED THAT IT HAS BEEN COMPLETELY REMOVED OR ERADICATED. THERE SHALL BE NO EXCEPTIONS TO THIS PROVISION. ALL LANDSCAPE ISLANDS AND BEDS WILL BE FREE OF SHELL ROCK AND CONSTRUCTION DEBRIS AND WILL BE EXCAVATED TO A DEPTH OF 30 INCHES OR TO CLEAN, NATIVE SOIL AND FILLED WITH THESPECIFIED REPLACEMENT SOIL. LANDSCAPE WARRENTY THE LANDSCAPE CONTRACTOR SHALL GUARANTEE ALL PLANT MATERIAL FOR A PERIOD OF SIX (6) MONTHS FROM THE DATE OF CONDITIONAL ACCEPTANCE IN WRITING FROM THE LANDSCAPE ARCHITECT. AT THE TIME OF CONDITIONAL ACCEPTANCE, THE SIX (6) MONTH PERIOD SHALL COMMENCE. ANY MATERIALS WHICH HAVE DIED OR DECLINED TO THE POINT WHERE THEY NO LONGER MEET FLORIDA #1 CONDTION DURING THIS PERIOD SHALL BE PROMPTLY REPLACED WITH SPECIMENS THAT MEET THE MINIMUM REQUIREMENTS CALLED FOR ON THE DRAWINGS. THE LANDSCAPE CONTRACTOR SHALL NOT BE HELD RESPONSIBLE FOR THE DEATH OR DAMAGE RESULTING FROM ACTS OF GOD SUCH AS LIGHTNING, VANDALISM, AND AUTOMOBILES OR FROM NEGLIGENCE BY THE OWNER. CONTRACTOR SHALL BE RESPONSIBLE FOR WATERING AND OTHERWISE MAINTAINING PLANTS UP TO THE CONDITIONAL ACCEPTANCE PERIOD, UNLESS A WRITTEN AGREEMENT WITH THE LANDSCAPE ARCHITECT PROVIDES FOR ADIFFERENT ARRANGEMENT. NTS TYPICAL LANDSCAPE BUFFER TYPICAL BUFFER SECTION NTS NTS NTS NTS Page 166 of 428 Environmental Impact Report (EIR) Walton Ranch 7001& 7201 Silver Oak Drive (±45.73 acres) Unincorporated St. Lucie County, Florida PINs: 3414-501-0602-000-8 & 3414-501-0615-000-2 Section 23, Township 36 S, Range 40 E Prepared For: St Lucie County Environmental Resource Department Prepared By: Jennifer Acevedo ENVIRONMENTAL CONSULTING DEPARTMENT CUSTOM DESIGNED RESEARCH EQUIPMENT AND CREATIVE RESEARCH SOLUTIONS ©Aquatic Research Monitoring, Equipment, and Deployment, LLC Revised June 2024 Page 167 of 428 PINs: 3414-501-0602-000-8 & 3414-501-0615-000-2 Walton Ranch 7001 & 7201 SE Silver Oak Drive, Unincorporated St. Lucie County Revised June 2024 Page 2 of 25 TABLE OF CONTENT INTRODUCTION ........................................................................................................................................ 3 1. Vegetation and Substrate Survey ....................................................................................................... 4 2. Statement of jurisdictional control over the environmental area .................................................... 9 3. Statement on when the jurisdictional boundaries were delineated and who delineated the boundaries. ............................................................................................................................................. 10 4. Indicate the required first floor elevation, and whether all floor elevations will be above this level. ........................................................................................................................................................ 11 5. Identification of any area that has experienced overwash of the primary dune. ......................... 11 6. Identification of any area subject to breach during storm conditions. ......................................... 11 7. Assessment of the impacts upon onsite vegetation and wildlife. .................................................... 11 8. Assessment of the impacts upon onsite and off-site natural resources. ......................................... 12 9. Detailed description of the planned approach to minimize impacts. ............................................. 13 10. Detailed description of the proposed alterations or disturbances being proposed..................... 18 11. Detailed description of the proposed mitigation plan to off set impacts. .................................... 19 12. Plant and animal survey for onsite federal and state protected species. ..................................... 22 13. Surface water management plan and written assessment including a description of techniques to be used to prevent both the potential degradation of surface water resources and an increase in flood hazard damage. ............................................................................................................................ 25 14. A sea turtle protection plan. ............................................................................................................ 25 15. A shoreline stabilization plan. ......................................................................................................... 25 16. A gopher tortoise protection plan. .................................................................................................. 25 Appendix A Maps Figure 1: Location Map Figure 2: Site Map Figure 3: Agency Reported Land Use/FLUCCS Figure 4: Gopher Tortoise, Listed Flora & Fauna with General Wildlife Survey Transect Figure 5: Existing Habitat Map Figure 6: Soils(s) Map Appendix B SFWMD Non Binding South Parcel and SFWMD Formal North Parcel Appendix C Wetland Impact Map Page 168 of 428 PINs: 3414-501-0602-000-8 & 3414-501-0615-000-2 Walton Ranch 7001 & 7201 SE Silver Oak Drive, Unincorporated St. Lucie County Revised June 2024 Page 3 of 25 INTRODUCTION The following environmental impact report has been prepared in accordance with Section 11.02.09(A) (5) of the St. Lucie County Land Development Code (LDC). The environmental impact report is required when the thresholds depicted in Section 11.02.09(A) (5) (a) are met. The Walton Ranch Project is ±45.73 acres located at 7001 & 7201 SE Silver Oak Drive within unincorporated St. Lucie County Florida. The subject property consists of two (2) parcels identified by the St. Lucie County Property Appraisers as Parcel Identification Numbers (PINs): 3414-501-0602-000-8 & 3414-501- 0615-000-2 located within Section 23, Township 36 South, and Range 40 East. Please see Appendix A, Figure 1 for the Location Map. The subject property is located on the fringe of an urban area near the Savannas State Park Conservation Lands. To the north is McQuillen Road and the Savannas Preserve State Park. South of the subject property is Tilton Road, followed by a single family home. Bordering along the west side is a sod and horse farm and to the east is SE Silver Oak Drive followed by Dorough Wholesale Nursery, ranchette style homes and undeveloped lands. The immediate surrounding area (±2.0 miles) consists of residential, commercial, and natural lands. This includes the Savannas Preserve State Park, St. Lucie River, Indian River Lagoon, and Myers-Stickel Park as well as the Spanish Lakes Subdivision and St Lucie Oaks Apartments. Commercial services include grocery stores, restaurants, gas stations, and car dealerships. Please see Appendix A, Figure 2 for the Site Map. The north portion of the subject property is currently in agricultural use as a horse boarding facility consisting of improved pasture and accessory structures consistent with an equine operation. The south portion of the property is vacant and heavily overgrown with dense exotic vegetation. Remnant structures related to previous equine use also remain on the south parcel. The sites natural features include four (4) isolated wetlands, classified as St. Lucie County Category III Wetlands. Additionally, two (2) of these onsite wetlands are less than 0.5 acres in size and therefore are not County jurisdictional. Remaining areas on site consist of improved pasture, Brazilian pepper, a farm pond and ditches classified as other surface waters (OSW’s). Wetlands as well as other surface waters located within the south property quadrant have been verified by South Florida Water Management District (SFWMD) in 2022 (Permit No. 56-107164-P). Page 169 of 428 PINs: 3414-501-0602-000-8 & 3414-501-0615-000-2 Walton Ranch 7001 & 7201 SE Silver Oak Drive, Unincorporated St. Lucie County Revised June 2024 Page 4 of 25 Wetlands within the north property quadrant/parcel have been verified by SFWMD through the Formal process in June 2024. See Appendix B for a copy of Permit No. 56- 107164-P and Permit No. 56-110381-P, Application No. 240214-42420. The proposed project is for a Planned Urban Development (PUD) with associated site improvements and requires an Environmental Impact Report (EIR) as part of the County approval process. See site plan submitted under separate cover. Please see Appendix C for proposed wetland impacts based on section 11.02.09(A) (5) of the St. Lucie County Land Development Code (LDC), the environmental impact report shall completely depict the following: 1. Vegetation and Substrate Survey a) Extent and acreage of any areas in which vegetation typical of the primary dune extends landward of the Coastal Construction Control Line (CCCL). The property is not located along the coast or near a waterway and therefore has no dune areas or CCCL line. b) Extent and acreage of all marsh and mangrove forest areas, including substrate conditions: Four isolated (4) wetlands as well as other surface waters (farm pond and ditches) are located on the subject property. Wetlands numbered as 1, 2, and 3 are located on Parcel 2 (South). Wetland number 4 is located on Parcel 1 (North). In 2022 an approved jurisdictional was completed by South Florida Water Management District for Parcel 2 (South) and in June 2024 an approved Jurisdictional through the formal process was completed for Parcel 1 (North). Both jurisdictional determinations can be found in Appendix B. Per the St. Lucie County Comprehensive Plan all onsite wetlands should be considered Category III wetlands as they are isolated systems and less than 5 acres in size. Additionally, Wetlands 1 and 3 have been state verified as less than 0.5 acres in size and therefore per Section 6.02.03B of the St. Lucie County Land Development Code (LDC), are not County jurisdictional. See Appendix A, Figure 3 for agency recorded FLUCCS codes and Figure 5 for existing Florida Land Use Classification Code System (FLUCCS) and Cooperative Land Use Code (CLC). Page 170 of 428 PINs: 3414-501-0602-000-8 & 3414-501-0615-000-2 Walton Ranch 7001 & 7201 SE Silver Oak Drive, Unincorporated St. Lucie County Revised June 2024 Page 5 of 25 Wetland FLUCCS/CLC classifications are as follows: Wetland 1: 630 FLUCCS/223 CLC: Exotic Hardwood Wetland (±0.1 ac) Permit No. 56-107164-P: Wetland 1 (W-1) is an isolated state jurisdictional wetland located in the NW corner of Parcel 2 (South). This wetland is dominated by exotic vegetation. This wetland is not county jurisdictional and will require no state mitigation for impacts. Representative Vegetation: Melaleuca (Melaleuca quinquenervia) – non-native Brazilian pepper (Schinus terebinthifolius – non-native Java plum (Syzygium cumini) – non-native Shoebutton ardisia (Ardisia elliptica) -non-native Wetland 2: 640 FLUCCS/2213 CLC: Vegetated Non-Forested Wetland (±2.9 ac) Permit No. 56-107164-P: Wetland 2 (W-2) is an isolated state jurisdictional wetland located in the SW corner of Parcel 2 (South). This wetland is best described as an herbaceous system almost solely consisting of nuisance and nonnative fast growing exotic species of plants. The density of exotic vegetation is inhibiting usage by wildlife and overall function as well as precluding use by larger mammals, and birds. Wetland 2 offers minimal wildlife support and access is severely limited to mainly reptiles and small rodents. The hydrology of this wetland appears to be altered via installation of a berm along the west side and swale to the south. This has resulted in a deep system that appears to receive sheet flow and back up from failure of the adjacent swale and berm. Wetland 2 also appears to receive untreated storm/agricultural runoff. Overall water depth, poor water quality input, and density of exotic vegetation has additionally resulted in algal buildup and subsequently poor light penetration, furthering recruitment of plants associated with poor water quality. Representative Vegetation: Shoebutton ardisia (Ardisia elliptica) – non-native Peruvian primrose-willow (Ludwigia peruviana) – non-native Wetland 3: 640 FLUCCS/2213 CLC: Vegetated Non-Forested Wetland (±0.2 ac) Permit No. 56-107164-P: Wetland 3 (W-3) is an isolated state jurisdictional wetland centrally located on Parcel 2 (South). This wetland is best described as an Page 171 of 428 PINs: 3414-501-0602-000-8 & 3414-501-0615-000-2 Walton Ranch 7001 & 7201 SE Silver Oak Drive, Unincorporated St. Lucie County Revised June 2024 Page 6 of 25 herbaceous system dominated by nuisance and non-native species. This wetland is not County jurisdictional and will require no state mitigation for impacts. Representative Vegetation: Shoebutton ardisia (Ardisia elliptica) – non-native Peruvian primrose-willow (Ludwigia peruviana) – non-native Wetland 4: 641 FLUCCS/2134 CLC: Maidencane Wetland (±1.3 ac) Wetland 4 (W-4) is an isolated state jurisdictional wetland, located along the western perimeter of Parcel 1 (North). This wetland is best described as an herbaceous pasture system dominated by maidencane. In its current condition it appears to offer partial wildlife support, mainly wading bird foraging. Based on the lack of vegetative cover, vegetation type and shallow depth this system is unsuitable for sandhill crane and/or wading bird nesting or roosting and overall limits other functions provided. Vegetative diversity is low with natural recruitment of other vegetative species not occurring with any significance. The system is best classified as a monoculture of maidencane and torpedo grass. Wetland 4 appears to have been historically part of pasture lands that now receive sufficient flow to maintain standing water in portions for 30 or more days. This has resulted in a very shallow system of 8-12” in depth with minor pockets of pickerelweed in the center. Hydrology appears to mainly be maintained as a result of sheet flow and back up of a swale system to the north and possibly west. Swales to the north are privately maintained and it was noted during site inspection that this system is not flowing/properly draining. Overall, this wetland system would appear to be experiencing moderate water quality impacts from the receipt of untreated water. Representative Vegetation: Torpedo grass (Panicum repens) – non-native Maidencane (Panicum hemitomon) – native Flatsedge (Cyperus spp) – non-native Other Surface Waters (OSWs) Two (2) other surface waters are located on the subject property. These include linear/channelized farm ditches as well as a watering pond for horses. The onsite OSW’s have no direct hydrological connection to the onsite wetlands, are maintained, and exhibit no apparent wetland function. Page 172 of 428 PINs: 3414-501-0602-000-8 & 3414-501-0615-000-2 Walton Ranch 7001 & 7201 SE Silver Oak Drive, Unincorporated St. Lucie County Revised June 2024 Page 7 of 25 524 FLUCCS /321 321: Artificial Pond (±0.1 ac) Permit Number 56-107164-P: A small pond is located on the south parcel; this pond has been classified as an other surface water (OSW) associated with the previous equine operation. 510 FLUCCS/422 CLC: Farm Ditch Along the northern boundary of the subject property is a series of linear farm ditches. The applicant is proposing to impact Wetlands 1, 3, a small portion of 2 and Wetland 4 in its entirety as part of site development. Wetlands 1 and 3 are both under 0.5 acres in size and therefore will not require state mitigation for impacts. Furthermore, as outlined in Section 6.02.03B of the St. Lucie County Land Development Code, wetlands under 0.5 acres in size are not County jurisdictional. Therefore, in accordance with the SFWMD Basis of Review and County LDC mitigation will solely be required for associated impacts to Wetlands 2 and 4. Mitigation for impacts shall be done in accordance with the SFWMD Basis of Review, of which shall specifically include enhancement and preservation of the remaining acreage of Wetland 2. Wetland 2 enhancement activities will include extensive exotic removal and revegetation within the wetland and buffer, full restoration of the 25 ft upland buffer, as well as stormwater improvements. Onsite stormwater improvements will cease the discharge of untreated water into this system, resulting in overall water quality improvements. Additionally, Wetland 2 and its restored 25-foot upland transitional buffer shall be placed under Conservation Easement with a Preserve Area Management Plan outlining proposed restoration activities as well as five (5) years of monitoring to ensure successful establishment of restoration plantings, perpetual maintenance and preservation requirements. c) Extent and acreage of all upland hammock forests; and, Upland areas on the subject property consist solely of non-native pasture type lands commensurate with the subject property’s use as an equine facility. The onsite pasture areas are in various stages of management. Pasture lands within the north parcel are best described as improved pasture utilized actively as outdoor runs for horse boarders and for operational aspects such as storage and as horse tack rooms and the like. The south parcel was historically pasture and has gone Page 173 of 428 PINs: 3414-501-0602-000-8 & 3414-501-0615-000-2 Walton Ranch 7001 & 7201 SE Silver Oak Drive, Unincorporated St. Lucie County Revised June 2024 Page 8 of 25 unmaintained. Due to lack of maintenance and agricultural activity on this portion of the subject property, exotic Brazilian pepper trees have established vegetative dominance. Therefore, the south parcel is currently best classified as Brazilian pepper. See Appendix A, Figure 3 for agency recorded FLUCCS codes and Figure 5 for existing Florida Land Use Classification Code System (FLUCCS) and Cooperative Land Use Code (CLC). Existing Upland Habitat FLUCCS/CLC Classifications Observed are as Follows: 211 FLUCCS/183213 CLC: Improved Pasture (±26.2 acres) This category in most cases is composed of land which has been cleared, tilled, reseeded with specific grass types and periodically improved with brush control and fertilizer application. Water ponds, troughs, feed bunkers and, in some cases, cow trails are evident. FLUCCS. Representative Vegetation: Non-descript and planted pasture grasses Oak trees (Quercus spp.) - native Cabbage palms (Sabal palmetto) - native 422 FLUCCS /73 CLC: Brazilian Pepper Tree (±14.9 acres) Exotic, pestilent tree species is found on peninsular Florida from the Tampa Bay area southward. Commonly found on disturbed sites, this native of Brazil is also an aggressive invader of Florida's plant communities. Communities of these small, shrub-like trees are often established along borrow-pits, levees, dikes and in old disturbed fields. (FLUCCS). Representative Vegetation: Brazilian Pepper (Schinus terebinfolia) – non-native As the Walton Ranch Site contains no native upland habitat, no native upland preserve is proposed. d) Extent and acreage of all wetlands. Four (4) state (SFWMD) jurisdictional isolated wetlands are located on the Walton Ranch subject property. Wetlands 1, 2, and 3 are located on Parcel 2 (South). Wetland 4 is located on Parcel 1 (North). In 2022 an approved Page 174 of 428 PINs: 3414-501-0602-000-8 & 3414-501-0615-000-2 Walton Ranch 7001 & 7201 SE Silver Oak Drive, Unincorporated St. Lucie County Revised June 2024 Page 9 of 25 jurisdictional was completed by South Florida Water Management District for Parcel 2 (South) and in June 2024 a formal jurisdictional was completed for Parcel 1 (North). Approved Jurisdictional can be found in Appendix B. Onsite wetlands would meet the classification of Category III Wetlands as all are isolated and less and 5 acres in size. Additionally, these wetlands are poor to moderate quality systems with vegetative, community structure, and hydrologic impacts associated with surrounding development as well as current and historical agricultural use of the subject property. Impacts are proposed to Wetlands 1 and 3, a small portion of 2 and Wetland 4 in its entirety. Remaining acreage of Wetland 2 is proposed for enhancement and preservation to offset mitigation. As also discussed in Question 1b above, the subject property also contains OSW’s that include a farm pond and ditches. FLUCCS 630/223: Non-Native Forested Wetland Wetland 1 (±0.1 acres) FLUCCS 6410/CLC 212: Vegetated Non-Forested Wetland Wetland 2 (±2.9 acres) Wetland 3 (±0.2 acres) FLUCCS 641/2134: Maidencane Wetland Wetland 4 (±1.3 acres) 524 FLUCCS/321 CLC: Artificial Farm Pond (±0.1 acres) 510 FLUCCS/422 CLC: Farm Ditches Please see the existing FLUCCS/habitat map (Appendix A, Figure 5) for further depiction of sizes and locations of all habitat types. 2. Statement of jurisdictional control over the environmental area The subject property has an approved SFWMD jurisdictional that was conducted in 2022 (Permit No. 56-107164-P) for Parcel 2 (South) and SFWMD conducted a formal jurisdiction in June 2024 for Parcel 1 (North) as reflected in Permit No. 56-110381-P, Application No. 240214-42420. Four (4) isolated wetlands are located on the subject property. Wetlands 1 (non- native forested), 2 (herbaceous), and 3 (herbaceous) are located on Parcel 2 Page 175 of 428 PINs: 3414-501-0602-000-8 & 3414-501-0615-000-2 Walton Ranch 7001 & 7201 SE Silver Oak Drive, Unincorporated St. Lucie County Revised June 2024 Page 10 of 25 (South). Wetland 4 (herbaceous) is located on Parcel 1 (North). These wetlands are under the jurisdiction of the South Florida Water Management District (SFWMD). A copy of the SFWMD approved wetland jurisdictionals are enclosed in Appendix B. All onsite wetlands are isolated systems, under 5 acres in size, and therefore are best classified as St. Lucie County Category III wetlands. Impacts are proposed to Wetlands 1,2, 3, and 4. Wetlands 1 and 3 are both under 0.5 acres in size and therefore will not require state mitigation for impacts. Furthermore, as outlined in Section 6.02.03B of the St. Lucie County Land Development Code, wetlands under 0.5 acres in size are not County jurisdictional. Therefore, in accordance with the SFWMD Basis of Review and County LDC mitigation will solely be required for associated partial impacts to Wetland 2 and full impacts to Wetland 4. Mitigation shall be done in accordance with the SFWMD Basis of Review. This will include enhancement and preservation of all remaining acreage of Wetland 2 (±2.7 acres), establishment of a 25 ft buffer with full restoration plantings, and placement of these lands under a Conservation Easement. No native uplands are present on the subject property, therefore no native upland preserve is proposed. St. Lucie County will maintain jurisdiction over on-site trees qualifying for protection under the Land Development Code (LDC). All cabbage palms over 10’ clear trunk (CT) and native hardwoods/softwoods over 12” diameter at breast height (DBH) will be mitigated at the site plan level either through preservation, over sizing of landscape trees, replanting, or a combination thereof. Tree mitigation shall be submitted by Cotleur and Hearing as part of the site’s landscape plan. 3. Statement on when the jurisdictional boundaries were delineated and who delineated the boundaries. The subject property has an approved jurisdictional that was conducted in 2022 for the south parcel and a formal jurisdictional for the north parcel in June 2024. The approved wetland determination (Permit No. 56-107164-P) for the south parcel identified three (3) wetlands and one (1) farm pond classified as an other surface water. For north parcel, Permit No. 56-110381-P, Application No. Page 176 of 428 PINs: 3414-501-0602-000-8 & 3414-501-0615-000-2 Walton Ranch 7001 & 7201 SE Silver Oak Drive, Unincorporated St. Lucie County Revised June 2024 Page 11 of 25 240214-42420 indicate one (1) isolated wetland along the western property boundary. A copy of both approved jurisdictional determinations are enclosed in Appendix B. 4. Indicate the required first floor elevation, and whether all floor elevations will be above this level. See site plan as prepared by others submitted under separate cover. 5.Identification of any area that has experienced overwash of the primary dune. No dune is present. Property is located inland. 6.Identification of any area subject to breach during storm conditions. Not applicable. 7. Assessment of the impacts upon onsite vegetation and wildlife. Development of the site will have impacts to protected trees. Trees shall be mitigated for via upsizing of required landscape trees, relocation, planting or a combination thereof. Tree mitigation shall be further addressed by Cotleur and Hearing and shall be demonstrated on the Landscape Plan. A listed flora and fauna survey was conducted by Aquatic Research FL in May, July, and again in August 2023. As part of the listed flora and fauna survey an FFWCC compliant inspection was also made for gopher tortoise burrows as well as burrowing owl burrows. See Appendix A Figure 4 for Transect Map and previous submittal Environmental Assessment with Listed Species Survey. Pedestrian transects and observations indicated no species of listed flora nor any listed species burrows, dens, roosting, or nesting areas. Two (2) species of wading birds state listed as threatened, the little blue heron and reddish egret were observed foraging within Wetland 4. However, the system is too open, and the height of vegetation and water depths are insufficient to support nesting sandhill cranes or colonial nesting wading birds. On May 8, 2023, July 27, 2023, and August 10 – 15, 2023, a 15% minimum habitat survey for gopher tortoise (Gopherus polyphemus) burrows and Page 177 of 428 PINs: 3414-501-0602-000-8 & 3414-501-0615-000-2 Walton Ranch 7001 & 7201 SE Silver Oak Drive, Unincorporated St. Lucie County Revised June 2024 Page 12 of 25 burrowing owl (Athene cunicularia) burrows was conducted. The gopher tortoise survey was executed according to the burrow survey methodology from the Florida Fish and Wildlife Conservation Commission Gopher Tortoise Permitting Guidelines, April 2008, Revised April 2023, Appendix 4 Burrow Survey Methods (Minimum of 15%). The burrowing owl survey was conducted according to the Florida Fish and Wildlife Conservation Commission Burrowing Owl Species Conservation Measures and Permitting Guidelines 2018. Survey results indicated no gopher tortoise or owl burrows on the subject property. Additionally, it should be noted that post completion of the survey it was determined that the South Parcel is unsuitable for the support of gopher tortoises and burrowing owls in its current condition. Please see previously submitted Environmental Survey, dated August 2023, for full listed species survey details and protocol. 8. Assessment of the impacts upon on-site and off-site natural resources. Proposed onsite alterations include impacts to non-native upland habitat (improved pasture and Brazilian pepper) and three (3) isolated wetlands (Wetlands 1, 3, a portion of 2, and 4). Wetlands 1 and 3 are both under 0.5 acres in size and therefore will not require state mitigation for impacts. Furthermore, as outlined in Section 6.02.03B of the St. Lucie County Land Development Code, wetlands under 0.5 acres in size are not County jurisdictional. Therefore, in accordance with the SFWMD Basis of Review and County LDC mitigation will solely be required for associated impacts to Wetlands 2 and 4. Mitigation shall be done in accordance with the SFWMD Basis of Review. Accordingly, the mitigation plan will offset impacts to Wetland 4 in its entirety, the partial direct impacts to Wetland 2 as well as any applicable secondary impacts resulting from partial removal of the 25 ft buffer. This includes enhancement and preservation of the remaining acreage of Wetland 2 as well as full restoration/creation of a 25-foot upland transitional buffer around Wetland 2. Wetland 2 with buffer enhancement activities will specifically include extensive exotic removal and revegetation as well as stormwater improvements. Onsite stormwater improvements will cease the discharge of untreated water into this system, resulting in overall water quality improvements. Additionally, Wetland 2 and its restored 25-foot upland transitional buffer shall be placed under Conservation Easement with a Preserve Area Management Plan outlining proposed restoration activities as well as perpetual maintenance and preservation Page 178 of 428 PINs: 3414-501-0602-000-8 & 3414-501-0615-000-2 Walton Ranch 7001 & 7201 SE Silver Oak Drive, Unincorporated St. Lucie County Revised June 2024 Page 13 of 25 requirements. This mitigation plan results in a surplus of mitigation being provided beyond the required amount of mitigation for proposed losses. See response to Question 11 of the EIR for mitigation details and impact calculations. With regards to tree mitigation all cabbage palms over 10’ clear trunk (CT) and native hardwoods/softwoods over 12” diameter at breast height (DBH) will be mitigated at the site plan level either through preservation, over sizing of landscape trees, replanting, or a combination thereof. A full mitigation plan shall be provided by Cotleur and Hearing as part of the project Landscape Plan. No impacts to offsite resources are proposed. Stormwater system also has been designed in accordance with state and federal required nutrient and discharge standards. 9. Detailed description of the planned approach to minimize impacts. The Walton Ranch site plan has been designed to incorporate the site’s natural features to the greatest possible extents while maintaining reasonable useability of the site. To achieve this goal during the initial planning process avoidance and minimization of impacts was extensively analyzed. To begin this process ecological assessments such as analysis of habitat types and quality, the location and jurisdictional boundaries of onsite wetlands as well as survey for listed flora and fauna were initiated. Results of these findings indicated that the subject property contained four (4) Category III Wetlands, other surface waters which included farm ditches and a pond, and non-native uplands associated with the site’s current as well as historical use in agricultural. Listed species surveys indicated no listed flora or fauna nesting, denning or roosting on the subject property. Wetland 4 however based on its proximity to the Savannas Conservation Area, was deemed suitable for wading bird forage solely. It was therefore determined that the ecological feature of highest value on the subject property was the presence of wetlands. The site’s greatest ecological benefit to the local region was determined to be wildlife support such as wading bird foraging, as well as providing flood protection and a nutrient sink, as is one of the main biological functions of a wetland to a region. Therefore, maintaining the site’s current ability to provide these functions was the design focus. Using the gathered data an alternative site plan analysis was conducted. Results are as follows: Page 179 of 428 PINs: 3414-501-0602-000-8 & 3414-501-0615-000-2 Walton Ranch 7001 & 7201 SE Silver Oak Drive, Unincorporated St. Lucie County Revised June 2024 Page 14 of 25 OPTION 1 NO NET LOSS OF WETLANDS The proposed development of the site is a single family residential PUD, of which is commensurate with the current zoning. To develop a residential PUD style neighborhood community amenities such as open and green space as well as preservation elements for passive use are highly valuable. Additionally, certain land to building ratios must be met to make the project viable from an economic standpoint. As the subject property was assessed to contain approximately ±4.5 acres of jurisdictional wetlands there was an initial loss of approximately 10% of marketable and financially positive space. Additionally, development of the community as a whole would further require the additional incorporation of various financially neutral components such as stormwater detention, parking, establishing county required setbacks, providing minimum lot sizes, garbage disposal, and interior roadways large enough to accommodate emergency services among other items. This further had the potential to reduce the total marketable building space by a possible range of 40% or more. A loss of that magnitude would not allow for development of a residential community within a price point feasible for middle and working class. These aforementioned factors resulted in a site plan with the need for innovative design and careful consideration of onsite and offsite ecological resources. Revised building cost estimates were then conducted considering options that included site development with partial impacts and full impacts (±4.5 acres). OPTION 2 FULL WETLAND IMPACTS The same process as discussed for the no wetland impact analysis was done to determine the feasibility of impacting all onsite wetlands. While environmental analysis of the onsite wetlands did not indicate the presence of systems of high ecological value, this option was regardless deemed unsuitable. Loss of all onsite wetlands would not meet local, state, or federal development and environmental protection standards, nor would it yield a community commensurate with the Meritage Home label of green conscious development. OPTON 3 PARTIAL WETLAND IMPACTS It was then further determined that an economically feasible site plan capable of the incorporation of all county, state, and federal site development requirements Page 180 of 428 PINs: 3414-501-0602-000-8 & 3414-501-0615-000-2 Walton Ranch 7001 & 7201 SE Silver Oak Drive, Unincorporated St. Lucie County Revised June 2024 Page 15 of 25 could be accomplished via a partial wetland impact option. The option of full impacts would not meet regulatory nor corporation development standards. No impacts would not yield a site plan capable of carrying a sufficient number of home sites required for an economically feasible project within the desired price point. Therefore, the next step in the overall analysis of avoidance and minimization was to determine the least amount of wetland impacts necessary within the areas of lowest ecological significance and how doing so would not just continue to provide but enhance the site’s ability to provide forage for wading birds and urban wildlife support. To accomplish this each existing wetland was examined for the following: location and landscape support, community structure, hydrology, wildlife usage and corridors, uniqueness to the region, among others. Analysis of Wetland 1: • Wetland 1 (W-1) is an isolated wetland located in the NW corner of Parcel 2 (South). • This wetland is almost solely exotic vegetation. • This wetland is less than 0.5 acres in size and therefore is not county jurisdictional and will require no state mitigation for impacts. • Density of exotic vegetation is severely limiting wildlife access and ability for natural recruitment. • This system demonstrates significant evidence of water quality degradation as well as poor light penetration hindering natural recruitment of native species. • Structural habitat is severely limited with generally poor plant conditions. Analysis of Wetland 2: • Wetland 2 (W-2) is an isolated wetland located in the SW corner of Parcel 2 (South) • Herbaceous system almost solely consisting of nuisance and non-native fast growing exotic species of plants. • The density of exotic vegetation is inhibiting usage by wildlife and overall function as well as precluding use by larger mammals, and birds. • Wetland 2 offers minimal wildlife support and access is severely limited to mainly reptiles and small rodents. Page 181 of 428 PINs: 3414-501-0602-000-8 & 3414-501-0615-000-2 Walton Ranch 7001 & 7201 SE Silver Oak Drive, Unincorporated St. Lucie County Revised June 2024 Page 16 of 25 • The hydrology of this wetland appears to be altered via installation of a berm along the west side and swale to the south, resulting in a deep system that appears to receive sheet flow and back up from failure of the adjacent swale and berm. • Receives untreated storm/agricultural runoff. • Overall water depth, poor water quality input, and density of exotic vegetation has additionally resulted in algal buildup and subsequently poor light penetration, furthering recruitment of plants associated with poor water quality. • Lack of natural fire regime. Analysis of Wetland 3: • Wetland 3 (W-3) is an isolated wetland centrally located on Parcel 2 (South). • This wetland is almost solely exotic vegetation. • This wetland is less than 0.5 acres in size and therefore is not county jurisdictional and will require no state mitigation for impacts. • Density of exotic vegetation is severely limiting wildlife access and ability for natural recruitment. • This system demonstrates significant evidence of water quality degradation as well as poor light penetration hindering natural recruitment of native species. • Structural habitat is severely limited with generally poor plant conditions. Analysis of Wetland 4: • Wetland 4 (W-4) is an isolated wetland, located along the western perimeter of Parcel 1 (North). • Herbaceous pasture wetland dominated by maidencane and torpedo grass. • Offers partial wildlife support, mainly wading bird foraging. • Based on the lack of vegetative cover, vegetation type and shallow depth this system is unsuitable for sandhill crane and/or wading bird nesting or roosting and overall limits other functions provided. • Vegetative diversity is low with natural recruitment of other vegetative species not occurring with any significance. • Historically part of pasture lands that now receive sufficient flow to maintain standing water in portions for 30 or more days. This has resulted Page 182 of 428 PINs: 3414-501-0602-000-8 & 3414-501-0615-000-2 Walton Ranch 7001 & 7201 SE Silver Oak Drive, Unincorporated St. Lucie County Revised June 2024 Page 17 of 25 in a very shallow system of 8-12” in depth with minor pockets of pickerelweed in the center. • Hydrology appears to mainly be maintained as a result of sheet flow and back up of a swale system to the north and possibly west. • Swales to the north are privately maintained and it was noted during site inspection that this system is not flowing/properly draining. • The wetland system would appear to be experiencing moderate water quality impacts from the receipt of untreated water. Based on these characterizations, all state and county jurisdictional wetlands were then assessed for impacts utilizing the state approved UMAM scoring system. UMAM scoring sheets were completed, resulting in a 4 (0.4 impact delta) for Wetland 2 and a 3 (0.3 impact delta) for Wetland 4. As it was determined that a final site plan that incorporated wetland preservation with minimal wetland impacts was the overall design goal, it was decided that impacts were best suited to Wetland 4 and a small portion of Wetland 2. All remaining acreage of Wetland 2 was to be enhanced and preserved in perpetuity. One of the main driving factors in this decision to focus impacts specifically on Wetland 4 was the poor hydrology associated with this system. Site analysis appeared to indicate that post development Wetland 4 will likely not be sustainable. The applicant is therefore proposing to impact Wetlands 4 as well as a small portion of Wetland 2, as part of site development. Wetlands 1 and 3 are also to be impacted however as both of these systems are under 0.5 acres in size, they are considered non county jurisdiction and require no mitigation for impacts. As both Wetlands 4 and 2 are considered Category III Wetlands, per County Comprehensive Plan they may be impacted if no reasonable alternative exists, and avoidance and minimization is demonstrated. Based on the above completed review avoidance and minimization of wetland impacts have been significantly analyzed via both economic and ecological standards. Mitigation shall be provided in accordance with the SFWMD Basis of Review and as discussed in Statement 11 below. Development of this Walton Ranch Project will result in legal conservation and enhancement of ±2.7 acres of wetland and ±0.7 acres of upland transitional buffer. Page 183 of 428 PINs: 3414-501-0602-000-8 & 3414-501-0615-000-2 Walton Ranch 7001 & 7201 SE Silver Oak Drive, Unincorporated St. Lucie County Revised June 2024 Page 18 of 25 Listed flora and fauna impacts were additionally reviewed to ensure avoidance and minimization of impacts to these resources was also adequately addressed and resulted in no loss of function. No listed flora species or listed fauna nests, dens, burrows, or roosting sites were found on the subject property. However, as previously mentioned it was determined that Wetland 4 had the potential to support wading birds. To compensate for this loss three (3) lakes shall be constructed and planted with viable littoral shelves. While compensating for the loss of wading bird forage is only a regulatory requirement for the federally protected wood stork, this shall still be accomplished using a similar approved methodology, as part of construction of the Walton Ranch Community. Additionally, as Wetland 2 shall be enhanced as part of the project’s mitigation plan, this system will obtain a future condition in which increased wildlife support is provided. Overall, the site plan as presented for Walton Ranch demonstrates the incorporation of avoidance and minimization of impacts. These factors were considered in great detail during all phases of project development and design. The resulting mitigation plan provides a sound design with minimal ecological impacts and on site and offsite enhancements that exceed proposed losses. 10. Detailed description of the proposed alterations or disturbances being proposed. The proposed project is for a Planned Urban Development (PUD) that includes residential parcels and associated site improvements. Development of the site will result in impacts to native and non-native uplands, as well as isolated wetlands. Mitigation shall be provided in accordance with the SFWMD Basis of Review and includes the enhancement and preservation of Wetland 2 via improvements to hydrology and community structure as well as reconstruction of a native wetland buffer. Therefore, project based impacts include alterations to non-native uplands (pasture and exotic vegetation) as well as impacts to non county jurisdictional isolated wetlands (less than 0.5 acres in size) and 2 low quality isolated wetlands. As mitigation for impacts enhancement and preservation of ±2.7 acres of onsite wetland along with a 25-foot transitional buffer will be provided. This mitigation plan results in a surplus of mitigation being provided by an additional functional gain of 0.57 Units beyond the required amount of mitigation for proposed losses. Page 184 of 428 PINs: 3414-501-0602-000-8 & 3414-501-0615-000-2 Walton Ranch 7001 & 7201 SE Silver Oak Drive, Unincorporated St. Lucie County Revised June 2024 Page 19 of 25 Removal of trees qualifying for protection under County standards shall be addressed by Cotleur and Hearing on the Landscape Plan. 11. Detailed description of the proposed mitigation plan to offset impacts. The site proposes no impacts to native uplands, or areas identified as unique to the region or supporting listed flora or fauna nesting, denning or roosting. Impacts are proposed to Wetlands 1, 3, a small portion of Wetland 2 and Wetland 4 in its entirety as part of site development. Wetlands 1 and 3 are both under 0.5 acres in size and therefore will not require state mitigation for impacts. Furthermore, as outlined in Section 6.02.03B of the St. Lucie County Land Development Code, wetlands under 0.5 acres in size are not County jurisdictional. Therefore, in accordance with the SFWMD Basis of Review and County LDC mitigation will solely be required for impacts to Wetlands 2 and 4. To determine the amount of required mitigation for partial impacts to Wetland 2 and full impacts to Wetland 4 the state approved UMAM scoring system has been utilized. Scoring sheets were completed for both direct and indirect (secondary) impacts. Scoring calculations are as follows: IMPACTS Wetland 4 (1.3 acres) – to be impacted in entirety – 1.3 acres of impacts Wetland 4 = Delta 0.3 Impacts – 0.3 X 1.3 acres of impacts = 0.4 Units of Functional Loss Wetland 2 (2.9 acres) with 0.2 acres of direct impacts and 0.09 acres of secondary impacts Wetland 2 = Delta 0.4 Direct impacts – 0.4 X 0.2 acres = 0.1 Units of Functional Loss Indirect impacts = Delta 0.1 – 0.1 X 0.09 acres = 0.01 Units of Functional Loss Total Impacts = 0.4 (WL4) + 0.1 (WL2) + 0.01 (WL 2 Secondary) = 0.51 Total Functional Loss MITIGATION Via Onsite Enhancement and Preservation Wetland 2 = 2.7 acres of enhancement and preservation Wetland 2 = Mitigation Delta of 0.4 and Relative Functional Gain of 0.4 Page 185 of 428 PINs: 3414-501-0602-000-8 & 3414-501-0615-000-2 Walton Ranch 7001 & 7201 SE Silver Oak Drive, Unincorporated St. Lucie County Revised June 2024 Page 20 of 25 Mitigation Calculation = 0.4 X 2.7 acres enhancement = 1.08 Total Units of Mitigation or Functional Gain Project Requires Offset of a Functional Loss of 0.51 Units 1.08-0.51 = 0.57 Units of Excess Mitigation Provided Onsite Mitigation Provides 1.08 Units of Lift – Therefore all Mitigation Provided Via Onsite Enhancement and Restoration of 2.7 acres of Wetland 2 with 0.57 Units in Excess Mitigation shall be done in accordance with the SFWMD Basis of Review, which shall specifically include enhancement and preservation of Wetland 2. Wetland 2 enhancement activities will include extensive exotic removal and revegetation as well as stormwater improvements. Onsite stormwater improvements will cease the discharge of untreated water into this system, resulting in overall water quality improvements. Additionally, Wetland 2 and its associated 25-foot upland transitional buffer shall be placed under Conservation Easement with a Preserve Area Monitoring and Maintenance Plan outlining proposed restoration activities as well as five (5) years of monitoring to ensure successful establishment of restoration plantings, perpetual maintenance and preservation requirements. As the buffer for Wetland 2 in its current state is dominated by exotic vegetation such as Brazilian pepper, a full restoration of the wetland buffer is also proposed. A representative planting table for one (1) typical section associated with the enhancement of Wetland 2 as well as the wetland buffer and well as the 0.09-acre section of modified transitional wetland buffer adjacent to the area of impacts are as follows: Wetland Restoration -Freshwater Marsh Typical 50' X 50' Section Zone Type Common Name Scientific Name Quantity Per One Typical Section Unit- (gal) Spacing- off center (o.c.) Understory Groundcover Swamp Lily Crinum americanum 89 br/liner 2’ Understory Groundcover Blue Flag Iris Iris virginica 89 br/liner 2’ Understory Groundcover Native rush Juncus spp. 89 br/liner 2' Page 186 of 428 PINs: 3414-501-0602-000-8 & 3414-501-0615-000-2 Walton Ranch 7001 & 7201 SE Silver Oak Drive, Unincorporated St. Lucie County Revised June 2024 Page 21 of 25 Understory Groundcover Softstem Bulrush Schoenoplectus tabernaemontani 89 br/liner 2’ Understory Groundcover Duck Potato Sagittaria latifolia 89 br/liner 2' Understory Groundcover Lanceleaf Arrowhead Sagittaria lancifolia 89 br/liner 2' Understory Groundcover Pickerelweed Ponterderia cordata 89 br/liner 2' Total Plants Installed 623 Wetland Buffer Restoration – Modified Transitional Buffer Total Area For Enhanced Erosion Sod to be Installed Native Grasses Interspersed 3,920 sq feet (0.09acres) Zone Type Common Name Scientific Name Quantity Per One Typical Section Unit- (gal) Spacing- off center (o.c.) Understory Groundcover Purple Love Grass Eragrostis spectabilis 327 br/liner 2' Understory Groundcover Muhly Grass Muhlenbergia capillaris 327 br/liner 2' Understory Groundcover Dwarf Fakahatchee Grass Tripsacum floridanum 327 br/liner 2' Total Plants Installed 981 Wetland Buffer Restoration – Freshwater Marsh Transitional Buffer 26,136 sq feet (0.6 acres) Zone Type Common Name Scientific Name Quantity Per One Typical Section Unit- (gal) Spacing- off center (o.c.) Canopy Tree Slash Pine Pinus elliottii 63 10 10 ' Midstory Shrub Saw Palmetto Serenoa repens 147 5 5' Midstory Shrub Gallberry Ilex glabra 147 5 5' Midstory Shrub Fetterbush Lyonia lucida 147 5 5' Understory Groundcover Purple Love Grass Eragrostis spectabilis 2,163 br/liner 2' Page 187 of 428 PINs: 3414-501-0602-000-8 & 3414-501-0615-000-2 Walton Ranch 7001 & 7201 SE Silver Oak Drive, Unincorporated St. Lucie County Revised June 2024 Page 22 of 25 Understory Groundcover Muhly Grass Muhlenbergia capillaris 2,163 br/liner 2' Understory Groundcover Dwarf Fakahatchee Grass Tripsacum floridanum 2,163 br/liner 2' Total Plants Installed 6,993 12. Plant and animal survey for onsite federal and state protected species. During the field assessment pedestrian transects were made throughout the subject property to observe for the presence of any state or federal listed flora and fauna species as well as wildlife in general. These included observations of individual animals as well as dens, burrows, rooting areas, or nests. Multiple linear transects were completed across representative portions of all habitat areas. Distances between transects varied in the field depending on terrain, with larger distances between open areas with low lying vegetation, smaller in areas with dense vegetation or suspected listed species occupation. One hundred (100) transects were established to perform the listed flora and fauna species survey. The survey conducted covered ±21.8 acres (±47%) of the ±45.73- acre subject property. See Appendix A, Figure 4 Survey Transect Map. Total Acreage of Property ±45.73 Total Acreage of Property Surveyed ±21.8 Total Percent of Property Surveyed 47% Property and surveyed acreage. No state or federal listed fauna species burrows, nests, dens, or roosting areas were observed on site. Two (2) species of wading birds state listed as threatened, the little blue heron and reddish egret were observed foraging within Wetland 4. However, the system is too open, and the height of vegetation and water depths are insufficient to support nesting sandhill cranes or colonial nesting wading birds. See tables below for the list of potential protected fauna species and species observations (listed and non-listed). Page 188 of 428 PINs: 3414-501-0602-000-8 & 3414-501-0615-000-2 Walton Ranch 7001 & 7201 SE Silver Oak Drive, Unincorporated St. Lucie County Revised June 2024 Page 23 of 25 Florida Natural Inventory Areas (FNAI) Biodiversity Index U.S. Fish and Wildlife Service (USFWS) Endangered Species List Information for Planning and Consultation (IPAC) Species Common Name Federal Status State Listing Observation(s) Mammal Presence Felis concolor coryi Florida panther puma E E None Observed Peromyscus polionotus niveiiventris Southeastern beach mouse T T None Observed Bird Presence Ammodramus savannarum floridanus Florida grasshopper sparrow E E None Observed Athene cunicularia floridana Florida burrowing owl C T None Observed Laterallus jamaicensis plancus audobonii Eastern black rail T T None Observed Egretta caerulea little blue heron N T Yes Egretta rufescens reddish egret N T Yes Egretta tricolor tri-colored heron N T None Observed Grus americana whooping crane E E None Observed Grus canadensis sandhill crane E E None Observed Mycteria americana woodstork T T None Observed Picoides borealis red-cockded woodpecker E E None Observed Platalea ajaja roseate spoonbill N T None Observed Polyborus plancus audubonii crested caracara T T None Observed Rostrhamus sociabillis plumbeus Everglades snail kite T T None Observed Reptile Presence Alligator mississippiensis American alligator T T None Observed Drymarchon corais couperi Eastern indigo snake T T None Observed Gopherus polyphemus gopher tortoise C T None Observed Insect Presence Cyclargus thomasi bethunebakeri Miami blue butterfly E E None Observed Danaus plexippus Monarch butterfly C NA None Observed Protected under the Migratory Bird Act Presence Aramus guarauna limpkin BCC N/A None Observed Page 189 of 428 PINs: 3414-501-0602-000-8 & 3414-501-0615-000-2 Walton Ranch 7001 & 7201 SE Silver Oak Drive, Unincorporated St. Lucie County Revised June 2024 Page 24 of 25 Ardea alba great egret N/A N/A Yes Ardea herodias occidentalis great blue heron N/A N/A Yes Arenaria interpres morinella ruddy turnstone BCC N/A None Observed Buteo brachyurus short-tailed hawk BCC N/A None Observed Caldris alpina arcticola dunlin BCC N/A None Observed Caldris pusilla semipalmated sandpiper BCC N/A None Observed Chaetura pelagica chimney swift BCC N/A None Observed Charadrius wilsonia Willson's plover BCC N/A None Observed Crotophaga ani smooth-billed ani BCC N/A None Observed Dendroica discolor prairie warbler BCC N/A None Observed Dendroica petechia gundlachi yellow warbler BCC N/A None Observed Egretta rufescens reddish egret BCC N/A None Observed Egretta thula snowy egret BCC N/A None Observed Elanoides forficatus swallow-tailed kite BCC N/A None Observed Falco sparverius paulus American kestrel BCC T None Observed Fregata magnificens magnificent frigatebird BCC N/A None Observed Haematopus palliatus American oystercatcher BCC T None Observed Haliaeetus leucocephalus bald eagle BCC N/A None Observed Limnodromus griseus short-billed dowitcher BCC N/A None Observed Melanerpes erythrocephalus red-headed woodpecker BCC N/A None Observed Numenius phaeopus whimbrel BCC N/A None Observed Passerina ciris painted bunting BCC N/A None Observed Rallus elegans king rail BCC N/A None Observed Rynchops niger black skimmer BCC T None Observed Sterna antillarum least tern BCC T None Observed Tringa avipes lesser yellowlegs BCC N/A None Observed Tringa semipalmata willet BCC N/A None Observed Vireo altiloquus black-whiskered vireo BCC N/A None Observed Table 3.2.B List of potential protected species and observations. Non-Listed Species Observation(s) Type Species Common Name Reptiles N/A N/A Mammals Mammal burrows N/A Aves Eudocimus albus white ibis Cyanocitta cristata blue jay Dendroica coerulescens black-throated blue warbler Bubulcus ibis cattle egret Page 190 of 428 PINs: 3414-501-0602-000-8 & 3414-501-0615-000-2 Walton Ranch 7001 & 7201 SE Silver Oak Drive, Unincorporated St. Lucie County Revised June 2024 Page 25 of 25 List of non-protected species and any observations. A state compliant Florida Fish & Wildlife Conservation Commission (FFWCC) 15% minimum habitat survey for gopher tortoise burrows as well as a burrowing owl survey was also conducted. No potentially occupied gopher tortoise or burrowing owl burrows were observed. It should also be noted that post completion of the listed flora and fauna survey, it was determined that the south parcel in its current condition is not suitable gopher tortoise nor burrowing owl habitat. 13. Surface water management plan and written assessment including a description of techniques to be used to prevent both the potential degradation of surface water resources and an increase in flood hazard damage. To be submitted under separate cover as part of engineering documents as applicable. 14. A sea turtle protection plan. Not applicable. 15. A shoreline stabilization plan. Not applicable. 16. A gopher tortoise protection plan. In May, July and August of 2023, Aquatic Research FL conducted a 15% minimum habitat survey for gopher tortoise burrows. No potentially occupied gopher tortoise burrows were observed. Page 191 of 428 Appendix B SFWMD Non Binding South Parcel Wetland Determination and SFWMD Formal North Parcel Determination ENVIRONMENTAL CONSULTING DEPARTMENT Aquatic RESEARCH Monitoring, Equipment, & Deployment, LLC. CUSTOM DESIGNED RESEARCH EQUIPMENT AND CREATIVE RESEARCH SOLUTIONS Page 192 of 428 Page 193 of 428 Page 194 of 428 Page 195 of 428 Page 196 of 428 June 4, 2024 * Delivered via email Douglas Lagler * Silver Oak Drive LLC 2359 SW Danforth Cir Palm City, FL 349900000 Subject: Walton Ranch Petition for Formal Determination of Wetlands and Surface Waters Permit No. 56-110381-P Application No. 240214-42420 St Lucie County Your petition for a formal determination of wetlands and other surface waters is approved.This action is taken based on Chapter 373,Part IV of Florida Statutes (F.S.)and the rules in Chapters 62-330 and 62-340,Florida Administrative Code (F.A.C.).Please read this entire agency action thoroughly and understand its contents. This action is subject to: Not receiving a filed request for a Chapter 120, F.S., administrative hearing. All referenced Exhibits. Should you object to these conditions,please refer to the attached "Notice of Rights"which addresses the procedures to be followed if you desire a public hearing or other review of the proposed agency action.Please contact this office if you have any questions concerning this matter.If we do not hear from you in accordance to the "Notice of Rights",we will assume that you concur with the District's action. CERTIFICATE OF SERVICE I hereby certify that this Formal Wetland Determination and Notice of Rights have been mailed or electronically submitted to the addressee (and the persons listed on the attached distribution list) on June 3,2024 in accordance with Section 120.60(3),F.S.Notice was also electronically posted on this date through a link on the home page of the District's website (www.sfwmd.gov/ ePermitting). Sincerely, Gary R. Priest, P.E. Engineering Section Administrator, Environmental Resource Bureau Page 197 of 428 South Florida Water Management District Formal Wetland Determination Permit No. 56-110381-P Date Issued: June 4, 2024 Project Name:Walton Ranch Petitioner:Douglas Lagler Silver Oak Drive LLC 2359 SW Danforth Cir Palm City, FL 349900000 Application No. 240214-42420 Location: St Lucie County, See Exhibit 1 Acres: 28.48 Expiration Date: June 4, 2029 Type: Certified Survey Summary On February 14,2024,the District received a request for a formal determination of the boundary of wetlands and other surface waters (OSWs)within one parcel totaling 28.48 acres,known as Walton Ranch.The landward extent of wetlands and OSWs was established by the petitioner and verified by District staff on May 21,2024,pursuant to Rule 62-330.201 F.A.C.The methodology used for the determination is consistent with Chapter 62-340, F.A.C. Site Description The property is located in Section 23,Township 36 South,Range 40 East,St.Lucie County.More specifically,the property is located approximately 3.5 miles north of Tilton Rd and directly west of Silver Oak Drive. The property is also bordered by recreational lands /wetlands to the north,and adjacent property owners to the west and south in which wetlands may be present. A Location Map is attached as Exhibit No. 1.0. Vegetative communities on the property consist of herbaceous wetlands and pasture uplands. Wetland Delineation Procedure Wetlands and OSWs,as defined by Subsection 373.019(27),F.S.and Chapter 62-340,F.A.C., were identified on the property.Wetlands were delineated using the methods established in Chapter 62-340,F.A.C.;more specifically,the wetlands were delineated using the A,B,C and D Tests,as well as the wetland definition.Wetlands delineated on the property totaled 1.327 acres and OSWs delineated on the property totaled 1.152 acres.A certified survey of these boundaries, dated May 17, 2024 is depicted as Exhibit No. 2.0. Wetland delineation information,including delineation data forms and representative photographs of the wetlands and upland areas,can be found in the permit file,on the District's ePermiting site. The wetland and upland delineation data forms were filled out by District staff during the March 21, 2024 field inspection. Wetland and Upland Description The site contains 26.001+/- acres of disturbed uplands used for an active horse farm/stables. The uplands transition into a herbaceous wetland system along the western portion of the Permit No: 56-110381-P, Page 2 Page 198 of 428 property. The wetland system is hydrologically connected to the adjacent ditch system on the western property boundary. Wetland vegetation onsite primarily includes pennywort (Centella asiatica),mermaid weed ( Proserpinaca palustris),waterhyssop (Bacopa monnieri),and Colombian waxweed (Cuphea carthagenensis). The wetland soils are composed of a thin layer of muck at the surface,meeting the requirements of the hydric soil indicator “Muck Presence”(A8)and "5cm Mucky Mineral"(A7).Based on a map produced using National Resource Conservation Service (NRCS)soil data,the soils supporting the wetland are mapped as 51—Waveland-Lawnwood complex,depressional,frequently ponded, 0 to 2 percent slopes,which is a hydric soil.The remainder of the site is mainly mapped as 21—Lawnwood and Myakka sands,no frequency of ponding,0 to 2 percent slopes and which is a non-hydric soil. Soil pits from the wetland and uplands were dug and the profiles examined by staff; the soil pit data are included in the data forms. Formal Determination of Wetlands and OSWs This Formal Determination of Wetlands and OSWs is the District's determination of the landward extent (boundaries)of wetlands and OSWs within the property based on the documentation submitted by the Petitioner and field application of Chapter 62-340, F.A.C. This action does not authorize any construction activities or constitute conceptual approval of any anticipated projects or activities in wetlands or OSWs.It does not in any way establish boundaries of sovereign submerged lands, high water elevations or other elevations / boundaries. Pursuant to Subsection 373.421 (4),F.S.,the Governing Board may revoke the Formal Wetland Determination (FWD)upon a finding that the Petitioner has submitted inaccurate information to the District. The FWD shall be binding for the stated duration provided physical conditions on the property do not change so as to alter the boundaries of wetlands and other surface waters during that period. Permit No: 56-110381-P, Page 3 Page 199 of 428 Distribution List Jeff Alexander, Meritage Home Of Fl * Jennifer Acevedo, Aquatic Research Monitoring Equipment and Deployment LLC * Michael Damelio * Florida Department of Environmental Protection SLERC * St. Lucie County Planning and Development Services * FDEP, Port St. Lucie Branch Office * Florida Department of Environmental Protection - Environmental Administrator * Permit No: 56-110381-P, Page 4 Page 200 of 428 Exhibits The following exhibits to this permit are incorporated by reference.The exhibits can be viewed by clicking on the links below or by visiting the District's ePermitting website ( http://my.sfwmd.gov/ePermitting)and searching under this application number 240214-42420. Exhibit No. 1.0 Location Map Exhibit No. 2.0 Survey Permit No: 56-110381-P, Page 5 Page 201 of 428 NOTICE OF RIGHTS As required by Chapter 120,Florida Statutes,the following provides notice of the opportunities which may be available for administrative hearing pursuant to Sections 120.569 and 120.57, Florida Statutes,or judicial review pursuant to Section 120.68,Florida Statutes,when the substantial interests of a party are determined by an agency. Please note that this Notice of Rights is not intended to provide legal advice. Some of the legal proceedings detailed below may not be applicable or appropriate for your situation. You may wish to consult an attorney regarding your legal rights. RIGHT TO REQUEST ADMINISTRATIVE HEARING A person whose substantial interests are or may be affected by the South Florida Water Management District’s (District)action has the right to request an administrative hearing on that action pursuant to Sections 120.569 and 120.57,Florida Statutes. Persons seeking a hearing on a District decision which affects or may affect their substantial interests shall file a petition for hearing in accordance with the filing instructions set forth herein within 21 days of receipt of written notice of the decision unless one of the following shorter time periods apply:(1)within 14 days of the notice of consolidated intent to grant or deny concurrently reviewed applications for environmental resource permits and use of sovereign submerged lands pursuant to Section 373.427,Florida Statutes;or (2)within 14 days of service of an Administrative Order pursuant to Section 373.119(1),Florida Statutes. "Receipt of written notice of agency decision"means receipt of written notice through mail,electronic mail,posting,or publication that the District has taken or intends to take final agency action. Any person who receives written notice of a District decision and fails to file a written request for hearing within the timeframe described above waives the right to request a hearing on that decision. If the District takes final agency action that materially differs from the noticed intended agency decision,persons who may be substantially affected shall,unless otherwise provided by law,have an additional point of entry pursuant to Rule 28-106.111, Florida Administrative Code. Any person to whom an emergency order is directed pursuant to Section 373.119(2),Florida Statutes,shall comply therewith immediately,but on petition to the board shall be afforded a hearing as soon as possible. A person may file a request for an extension of time for filing a petition. The District may grant the request for good cause. Requests for extension of time must be filed with the District prior to the deadline for filing a petition for hearing. Such requests for extension shall contain a certificate that the moving party has consulted with all other parties concerning the extension and whether the District and any other parties agree to or oppose the extension. A timely request for an extension of time shall toll the running of the time period for filing a petition until the request is acted upon. FILING INSTRUCTIONS A petition for administrative hearing must be filed with the Office of the District Clerk. Filings with the Office of the District Clerk may be made by mail,hand-delivery,or e-mail. Filings by facsimile will not be accepted. A petition for administrative hearing or other document is deemed filed upon receipt during normal business hours by the Office of the District Clerk at the District’s headquarters in West Palm Beach,Florida. The District’s normal business hours are 8:00 a.m.– 5:00 p.m.,excluding weekends and District holidays. Any document received by the Office of the District Clerk after 5:00 p.m.shall be deemed filed as of 8:00 a.m.on the next regular business day. Additional filing instructions are as follows: Filings by mail must be addressed to the Office of the District Clerk,3301 Gun Club Road, West Palm Beach, Florida 33406. Filings by hand-delivery must be delivered to the Office of the District Clerk. Delivery of a petition to the District's security desk does not constitute filing. It will be necessary to request Permit No: 56-110381-P, Page 6 Page 202 of 428 that the District's security officer contact the Office of the District Clerk. An employee of the District's Clerk's office will receive and process the petition. Filings by e-mail must be transmitted to the Office of the District Clerk at clerk@sfwmd.gov. The filing date for a document transmitted by electronic mail shall be the date the Office of the District Clerk receives the complete document. INITIATION OF ADMINISTRATIVE HEARING Pursuant to Sections 120.54(5)(b)4.and 120.569(2)(c),Florida Statutes,and Rules 28-106.201 and 28-106.301,Florida Administrative Code,initiation of an administrative hearing shall be made by written petition to the District in legible form and on 8 1/2 by 11 inch white paper. All petitions shall contain: Identification of the action being contested,including the permit number,application number, District file number or any other District identification number, if known. 1. The name,address,any email address,any facsimile number,and telephone number of the petitioner, petitioner’s attorney or qualified representative, if any. 2. An explanation of how the petitioner’s substantial interests will be affected by the agency determination. 3. A statement of when and how the petitioner received notice of the District’s decision.4. A statement of all disputed issues of material fact. If there are none,the petition must so indicate. 5. A concise statement of the ultimate facts alleged,including the specific facts the petitioner contends warrant reversal or modification of the District’s proposed action. 6. A statement of the specific rules or statutes the petitioner contends require reversal or modification of the District’s proposed action. 7. If disputed issues of material fact exist,the statement must also include an explanation of how the alleged facts relate to the specific rules or statutes. 8. A statement of the relief sought by the petitioner,stating precisely the action the petitioner wishes the District to take with respect to the District’s proposed action. 9. MEDIATION The procedures for pursuing mediation are set forth in Section 120.573,Florida Statutes,and Rules 28-106.111 and 28-106.401–.405,Florida Administrative Code. The District is not proposing mediation for this agency action under Section 120.573, Florida Statutes, at this time. RIGHT TO SEEK JUDICIAL REVIEW Pursuant to Section 120.68,Florida Statutes,and in accordance with Florida Rule of Appellate Procedure 9.110,a party who is adversely affected by final District action may seek judicial review of the District's final decision by filing a notice of appeal with the Office of the District Clerk in accordance with the filing instructions set forth herein within 30 days of rendition of the order to be reviewed,and by filing a copy of the notice with the appropriate district court of appeals via the Florida Courts E-Filing Portal. Permit No: 56-110381-P, Page 7 Page 203 of 428 Source: Esri, Maxar,Earthstar ¯ Exhibit No: 240214-4242000.150.075 Miles Application No: 240214-42420 FWD No: 56-110381-P Project Name: WALTON RANCH Map Date: 2024-06-03 Application ST LUCIE COUNTY, FLORIDA Page 204 of 428 LOTS 16, BLOCK 3, PLAT NO. 1, ST. LUCIE GARDENS BY THE INDIAN RIVER (PLAT BOOK 1, PAGE 35) LOTS 1, BLOCK 2 (PLAT BOOK 1, PAGE 35) LOTS 3, BLOCK 2 (PLAT BOOK 1, PAGE 35) LO T S 4 , B L O C K 2 ( P L A T B O O K 1 , P A G E 3 5 ) LOTS 14, BLOCK 3, PLAT NO. 1, ST. LUCIE GARDENS BY THE INDIAN RIVER (PLAT BOOK 1, PAGE 35)LOTS 13, BLOCK 3, PLAT NO. 1, ST. LUCIE GARDENS BY THE INDIAN RIVER (PLAT BOOK 1, PAGE 35) FL FL FL FL FL FL FL F L F L FL F L F L FL F L FL FL FL FL FL FL FL FL FL FL FL FL F L F L F L F L F L F L F L F L F L F L F L F L F L F L F L F L F L F L F L F L F L F L F L F L FL F L F L FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL F L FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL TOTAL (27.664 ACRES MORE OR LESS) SITE LO T S 1 , 2 A N D 3 B L O C K 2 , S E C T I O N 2 3 , T O W N S H I P 3 6 S O U T H , RA N G E 4 0 E A S T , P L A T N O . 1 , S T . L U C I E G A R D E N S B Y T H E I N D I A N RI V E R , A S R E C O R D E D I N T H A T C E R T A I N P L A T R E C O R D E D I N P L A T BO O K 1 , P A G E 3 5 O F T H E P U B L I C R E C O R D S O F S T . L U C I E CO U N T Y , F L O R I D A ; L E S S R D . T H A T P A R T L Y I N G I N R I G H T O F W A Y IF A N Y . A L T A / N S P S L A N D T I T L E S U R V E Y LA N D S C A P E A R C H I T E C T U R E - S U R V E Y I N G CA U L F I E L D & W H E E L E R , I N C . CI V I L E N G I N E E R I N G - L A N D P L A N N I N G PH O N E ( 5 6 1 ) - 3 9 2 - 1 9 9 1 / F A X ( 5 6 1 ) - 7 5 0 - 1 4 5 2 79 0 0 G L A D E S R O A D - S U I T E 1 0 0 BO C A R A T O N , F L O R I D A 3 3 4 3 3 Exhibit No 2.0 FWD No. 56-110381-P 1 of 2Page 205 of 428 LOTS 2, BLOCK 2 (PLAT BOOK 1, PAGE 35) LOTS 3, BLOCK 2 (PLAT BOOK 1, PAGE 35) LOTS 4, BLOCK 2, (PLAT BOOK 1, PAGE 35) LOTS 14, BLOCK 2 (PLAT BOOK 1, PAGE 35) LOTS 13, BLOCK 2 (PLAT BOOK 1, PAGE 35) X X X X X X X X X X FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL F L F L FL FL FL FL FL FL FL FL FL F L FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL F L FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL F L F L F L FL FL FL LOTS 15, BLOCK 2 (PLAT BOOK 1, PAGE 35) LOTS 2, BLOCK 2 (PLAT BOOK 1, PAGE 35) LOTS 3, BLOCK 2 (PLAT BOOK 1, PAGE 35) WETLAND 4 (WETLAND LIMITS AS APPROVED BY SFWMD MARCH 2024) 1.327 ACRES MORE OR LESS TOTAL (27.664 ACRES MORE OR LESS) LA N D S C A P E A R C H I T E C T U R E - S U R V E Y I N G CA U L F I E L D & W H E E L E R , I N C . CI V I L E N G I N E E R I N G - L A N D P L A N N I N G PH O N E ( 5 6 1 ) - 3 9 2 - 1 9 9 1 / F A X ( 5 6 1 ) - 7 5 0 - 1 4 5 2 79 0 0 G L A D E S R O A D - S U I T E 1 0 0 BO C A R A T O N , F L O R I D A 3 3 4 3 3 LO T S 1 , 2 A N D 3 B L O C K 2 , S E C T I O N 2 3 , T O W N S H I P 3 6 S O U T H , RA N G E 4 0 E A S T , P L A T N O . 1 , S T . L U C I E G A R D E N S B Y T H E I N D I A N RI V E R , A S R E C O R D E D I N T H A T C E R T A I N P L A T R E C O R D E D I N P L A T BO O K 1 , P A G E 3 5 O F T H E P U B L I C R E C O R D S O F S T . L U C I E CO U N T Y , F L O R I D A ; L E S S R D . T H A T P A R T L Y I N G I N R I G H T O F W A Y IF A N Y . A L T A / N S P S L A N D T I T L E S U R V E Y Exhibit No 2.0 FWD No. 56-110381-P 2 of 2Page 206 of 428 Appendix C Wetland Impact Map ENVIRONMENTAL CONSULTING DEPARTMENT Aquatic RESEARCH Monitoring, Equipment, & Deployment, LLC. CUSTOM DESIGNED RESEARCH EQUIPMENT AND CREATIVE RESEARCH SOLUTIONS Page 207 of 428 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM WETLAND 1 WETLAND 4 WETLAND 2 WETLAND 3 WETLAND IMPACT GRADE 4:1 TO MEET ELEVATION OF WETLAND. QUANTIFICATION OF SECONDARY IMPACTS .09 AC. 30' 25' 25' 1 50' Scale: 1" = 100' 0'100'300'200' North 400' WETLAND EXHIBIT by agreement in writing with the architect. Immediately report any discrepancies to the architect. SHEET COTLEUR & HEARING, INC. These drawings are the property of the architect and are not to be used for extensions or on other projects except OF DESIGNED DRAWN APPROVED JOB NUMBER REVISIONS DATE Landscape Architects Land Planners Environmental Consultants www.cotleurhearing.com 1934 Commerce Lane Suite 1 Jupiter, Florida 33458 561.747.6336 · Fax 747.1377 Lic# LC-C000239 LAH/TJB TJB LAH 1 23-0312 St . L X c L e C o X Q t \ F l o r L G a WA L T O N R A N C H - M E R I T A G E H O M E S 06-10-24 WETLAND DATA KEY MAP MCQUILLEN RD TILTON RD DYER RD LE N N A R D R D SI L V E R O A K D R SH A N A S T R A I L S U S H W Y 1 SITE SAVANNAHS PRESERVE STATE PARK WETLAND 1: +/- .1 AC CATEGORY 3 +/- .1 AC TO BE IMPACTED WETLAND 2: +/- 2.85 AC CATEGORY 3 +/- .12 AC TO BE IMPACTED +/- 2.64 AC TO BE PRESERVED +/- .30 AC TO BE CONSTRUCTED BUFFER +/- .26 AC TO BE CONSTRUCTED BUFFER WITH TEMPORARY IMPACTS +/- .09 AC TO BE IMPACTED WITH GRADING TO WETLAND WETLAND 3: +/- .2 AC CATEGORY 3 +/- .2 AC TO BE IMPACTED WETLAND 4: +/- 1.33 AC CATEGORY 3 +/- 1.33 AC TO BE IMPACTED TOTAL WETLAND ACREAGE: 4.48 AC TOTAL WETLAND PRESERVED: 2.64 AC TOTAL WETLAND IMPACTED: 1.84 AC Page 208 of 428 Appendix D Environmental Assessment ENVIRONMENTAL CONSULTING DEPARTMENT Aquatic RESEARCH Monitoring, Equipment, & Deployment, LLC. CUSTOM DESIGNED RESEARCH EQUIPMENT AND CREATIVE RESEARCH SOLUTIONS Page 209 of 428 Environmental Assessment Walton Ranch 7001& 7201 Silver Oak Drive (±46.5 acres) Unincorporated St. Lucie County, Florida PINs: 3414-501-0602-000-8 & 3414-501-0615-000-2 Section 23, Township 36 S, Range 40 E Prepared For: St. Lucie County Environmental Resources Department (ERD) & Meritage Homes of Florida Inc 1400 Centrepark Blvd., Suite 1000 West Palm Beach, Florida 33401 Prepared By: Jennifer Acevedo Jennifer Acevedo December 2023 ENVIRONMENTAL CONSULTING DEPARTMENT © Aquatic RESEARCH Monitoring, Equipment, & Deployment, LLC. Page 210 of 428 Environmental resources Final report TO:Irene Szedlmayer, Planning & Development Services THROUGH:Aimee L. Cooper, Environmental Regulations Manager Amy E. Griffin, Environmental Resources Director FROM:Brian Arbeiter, Senior Environmental Planner DATE:July 1st, 2024 SUBJECT:Walton Ranch PUD Rezoning/Preliminary Plan RZ-2312-000029 Background The Environmental Resources Department (ERD) is in receipt of the June 17th, 2024, date-stamped submittal transmitted on June 18th, 2024, with comments due July 3rd, 2024, from Planning and Development Services. The applicant is seeking approval of a rezoning from Residential Multi-Family - 5 (RM-5) and Agricultural Residential – 1 (AR-1) to Planned Unit Development (PUD). The preliminary site plan proposes 141 single- family lots, three (3) lakes, associated site improvements, and the preservation of a 2.64-acre wetland. The project is located at 7101 Silver Oak Dr & 7287 Silver Oak Dr and currently consists of two (2) parcels (Parcel IDs 3414-501-0602-000-8 & 3414-501-0615-000-2) collectively measuring 45.73 acres. Findings An Environmental Impact Report (EIR) prepared by Aquatic Research, Monitoring, Equipment, & Deployment, LLC., dated June 2024, was provided and reviewed. No native upland habitat was identified onsite. The northern half of the property contains improved pasture and currently serves as a horse boarding facility. The southern half of the property is vacant land overgrown with invasive vegetation, which was also previously impacted by agricultural activity. Observed native vegetation includes cabbage palms, live oaks, laurel oaks, and maidencane. Observed non-native vegetation includes a variety of pasture grasses, Brazilian pepper, melaleuca, shoebutton ardisia, java plum and Peruvian primrose-willow. No listed species were observed during field surveys. A 100% gopher tortoise survey in accordance with Florida Fish and Wildlife Conservation Commission (FWC) will be required prior to development activities. Two (2) other surface water (OSWs) bodies, a ditch system and a 0.1-acre artificial pond, along with four (4) isolated low to moderate quality Category III wetlands, respectively measuring 0.1-acres (Wetland 1), 2.9- acres (Wetland 2), 0.2-acres (Wetland 3), and 1.3-acres (Wetland 4), were identified onsite. Wetland 1 is best classified as an exotic hardwood wetland, Wetlands 2 and 3 as vegetated non-forested wetlands, and Wetland 4 as a maidencane wetland. The limits of the four (4) wetlands were verified by the South Florida Water Management District (SFWMD) via an informal wetland determination (No. 56-107164-P) for Wetlands 1, 2, & 3 located within the southern parcel, and a formal wetland determination (No. 56-110381-P) for Wetland 4 located within the northern parcel. The development proposes impacts to both OSWs, 1.8 acres of direct wetland impacts, 0.09 acres of indirect wetland impacts, and 2.7 acres of wetland preservation and restoration. More specifically, the entirety of Wetlands 1, 3, and 4, along with 0.2 acres of Wetland 2 are proposed to be impacted. The remaining 2.7 acres of Wetland 2 and surrounding twenty-five (25) ft. wide upland buffer, will be restored, maintained, and protected in perpetuity by a conservation easement (CE) and a preserve area Page 211 of 428 monitoring and management plan (PAMMP). No mitigation will be required by SFWMD for the impacts to Wetlands 1 or 3 as both measure under a half of an acre. According to the provided uniform mitigation assessment method (UMAM) scores, the restoration of the remaining Wetland 2 acreage (2.7 acres) will provide 0.57 units of excess mitigation credit after accounting for the impacts (1.5 acres) to Wetland 2 & 4. This indicates that no purchase of wetland mitigation bank credits will be required, which will be verified via receipt of the project’s Environmental Resource Permit (ERP) issued by SFWMD. A landscape plan prepared by Cotleur & Hearing, dated June 17th, 2024, was found to be consistent with the standards for preliminary plans outlined in LDC 11.02.10.A.3. A six (6) ft. tall PVC fence with augmented landscaping is proposed within a forty (40) ft. wide landscape buffer along the eastern perimeter abutting the Silver Oak Drive right-of-way to help buffer existing single-family residences to the east. A twenty-five (25) ft. wide landscape buffer is provided along the northern and western perimeters to help buffer the Savannas Preserve State Park to the north and the existing business to the west. The proposed project will impact a total of approximately twenty-four (24) cabbage palms and 1,140 inches diameter at breast height (DBH) of native canopy trees meeting minimum mitigation size thresholds outlined in LDC 6.00.05.D, resulting in a total of twenty-four (24) cabbage palms and 2,280 inches DBH of required tree mitigation. A total of six (6) cabbage palms and 522 inches of oaks and slash pines are proposed to be preserved onsite, which equates to six (6) cabbage palms and 1,044 inches of preservation credit. Currently, a total of eighteen (18) cabbage palms and 622.5 inches DBH of live oak and slash pine are proposed to be planted onsite. The remaining 613.5 inches DBH of required mitigation is to be met via a fee-in-lieu, additional preservation, and/or additional plantings of native canopy trees, consistent with the tree mitigation standards outlined within LDC 6.00.05.D. Recommendation ERD has no objection to the Planned Unit Development rezoning with conditions outlined below. Conditions of Approval 1) Prior to final site plan approval, a finalized tree mitigation plan consistent with Land Development Code 6.00.05.D shall be provided. 2) Prior to final site plan approval, a finalized landscape plan consistent with Land Development Code 7.09.00 shall be provided, which includes the following revisions: a. Specify all proposed canopy trees utilized to fulfill landscaping and upland buffer requirements, including green buttonwoods, red maples, and bald cypress, to measure a minimum of two and a half (2.5) inches diameter at breast height (DBH) and five (5) ft. crown spread in accordance with LDC 7.09.03.E.2.d. b. A root barrier typical consistent with LDC 7.09.03.E.2.e and corresponding root barrier locations shall be provided for those trees whose roots are known to cause damage to public roadways or other public works and are planted closer than twelve (12) feet to such public roads or works. c. Number the canopy trees to be preserved as to correlate to the tree mitigation plan. 3) Prior to final site plan approval, relabel the thirty (30) ft. wide area that lies between Lots 136-140 on the site plan as a ‘modified transitional upland buffer’. 4) Prior to final site plan approval, provide a revised boundary survey that depicts the limits of the three (3) wetlands located on the south parcel (Parcel ID 3414-501-0615-000-2) in accordance with LDC 11.02.09.A. 5) Prior to commencement of development, including, but not limited to clearing, filling, excavation, grading, or planting of vegetation, as defined in LDC 2.00.00, the developer shall provide an executed Conservation Easement over the onsite wetland and associated upland buffer, along with the approved Preserve Area Monitoring and Management Plan (PAMMP), with an attached affidavit and cashier's Page 212 of 428 check (payable to the Clerk of the Court for recording fees) to the County Attorney. The applicant shall also provide a georeferenced GIS shapefile or CAD file of the conservation easements’ boundaries to St. Lucie County. 6) Prior to commencement of development, including, but not limited to clearing, filling, excavation, grading, or planting of vegetation, as defined in LDC 2.00.00, updated listed species surveys shall be provided per state and/or federal survey protocol. Should any listed species be found as a result of these surveys, appropriate permits from state and federal agencies shall be required. 7) Prior to issuance of a Certificate of Occupancy, all Category I listed invasive plants shall be eradicated from the site. Please contact Brian Arbeiter at 772-462-2866 if you have any questions. Page 213 of 428 WALTON RANCH TRAFFIC IMPACT STUDY Prepared for MERITAGE HOMES Prepared by PINDER TROUTMAN CONSULTING, INC. 601 Heritage Drive, Suite 493 Jupiter, FL 33458 (561) 296-9698 #PTC23-081 August 29, 2023 Revised December 15, 2023 Revised March 21, 2024 Rebecca J. Mulcahy, State of Florida, Professional Engineer, License No. 42570 This item has been electronically signed and sealed by Rebecca J. Mulcahy, P.E. on 3/21/24 using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Page 214 of 428 WALTON RANCH LIST OF EXHIBITS AND APPENDICES EXHIBITS Exhibit 1 Project Location Exhibit 2 Trip Generation Exhibit 3A Project Traffic Distribution Exhibit 3B AM Peak Hour Project Traffic Assignment Exhibit 3C PM Peak Hour Project Traffic Assignment Exhibit 4 Historic Growth Exhibit 5A Intersection Analysis Exhibit 5B Intersection Queues Exhibit 6 Link Analysis Exhibit 7 Project Driveway Volumes Exhibit 8 Left Turn Lane Determination APPENDICES Appendix A Conceptual Site Plan Appendix B Traffic Count Data Appendix C Trip Generation Data Appendix D Committed Development Data Appendix E Intersection Analyses Page 215 of 428 Report 23-081 3-21-24 Pinder Troutman Consulting, Inc. 1 WALTON RANCH TRAFFIC IMPACT STUDY Introduction Pinder Troutman Consulting, Inc. (PTC) has been retained to conduct a traffic impact analysis for a proposed residential development located in St. Lucie County. The purpose of this study is to examine the traffic impacts of the proposed development on the surrounding roadway network and to determine compliance with Chapter V – Adequate Public Facilities, of the St. Lucie County Land Development Code. Site Data The site, which currently contains an equestrian boarding facility, is located on the west side of Silver Oaks Drive between Tilton Road and MacQuillen Road, as shown on Exhibit 1. The proposed Project consists of 141 single family dwelling units. Proposed access to the site is via one driveway connection to Silver Oaks Drive. See Appendix A for Conceptual Site Plan. Any reference to intersection geometrics is conceptual in nature and subject to final design and approval by others. A 2026 buildout is proposed. Existing Traffic Conditions The latest available daily and peak hour traffic volumes and adopted level of service volumes for the surrounding roadway links were used. The sources of the traffic count data are the St. Lucie TPO "Traffic Counts and Level of Service Report, 2023". Additionally, intersection counts were obtained in October 2023. All traffic counts and peak season factor reports are provided in Appendix B. Roadway Improvements The latest Transportation Improvement Program from the St. Lucie TPO was reviewed to determine if any roadways within the study area are scheduled to be improved during the buildout of this project. There are no scheduled construction projects at this time. Page 216 of 428 Report 23-081 3-21-24 Pinder Troutman Consulting, Inc. 2 Trip Generation The Institute of Transportation Engineers (ITE), Trip Generation, 11th Edition was reviewed to determine acceptable daily and peak hour trip generation rates for the proposed project. Exhibit 2 provides the daily, AM and PM peak hour trip generation data for the proposed development. Appendix C contains excerpts from the Trip Generation manual for this use. Based on these calculations, the Project generates 1,384 daily, 102 AM peak hour and 137 PM peak hour trips. Based on the daily trips, a two-mile radius of development influence is required. Trip Distribution and Assignment A directional distribution was developed based on a review of land use patterns, existing travel patterns and the roadway network. The resultant Project distribution is shown on Exhibit 3A. Exhibits 3B and 3C show the assignment of AM and PM peak hour Project traffic on the surrounding roadway network, as well as the Project’s impact percentage (% of peak hour directional service volume) to determine Project significance. Project traffic is considered to be significant on the directly accessed Major Road where Project traffic consumes one percent or more of the directional capacity, and on any other Major Road within two miles where Project traffic consumes five percent or more of the directional capacity. Therefore, the significantly impacted roadway links are Lennard Road Extension and Prima Vista Boulevard in both peak hours. Historic Growth Historic growth trends must be analyzed in the projection of future background traffic volumes. Historic growth data was obtained from the St. Lucie County TPO and is shown on Exhibit 4 for the surrounding roadway links. The average annual growth and the trendline growth for the area are both negative. There are two approved projects in the area, Prima Vista Commons and Silver Oaks PUD. Excerpts from these traffic studies are provided in Appendix D. In order to account for area growth, a comparison was made using the committed development traffic and 1% growth versus a conservative 2% growth rate. The largest background growth was used in the link and intersection analyses. Page 217 of 428 Report 23-081 3-21-24 Pinder Troutman Consulting, Inc. 3 Intersection Analysis Intersection capacity analyses are required for the major intersections within a significantly impacted roadway segment. The intersections of Prima Vista Boulevard with US 1 and Lennard Road Extension, as well as Silver Oaks Drive with Tilton Road and the Site Driveway were analyzed using Highway Capacity Manual procedures. Turning movement counts for these intersections were collected in October 2023 and are included in Appendix B. Projected, year 2026, background traffic was calculated based on the larger of committed development and 1% growth or a 2% growth rate. Project traffic was then added to the background traffic. The intersection worksheets and HCS capacity analyses are provided in Appendix E. The level of service (LOS) results are summarized on Exhibit 5A. The queues for turning movements utilized by Project traffic are shown on Exhibit 5B. The intersection of Prima Vista Boulevard and US 1 is projected to operate at LOS E (AM) and F (PM) in 2026 with and without the Project traffic. Therefore, according to Florida Statute 163.3180, this intersection is considered a "transportation deficiency". "The improvement necessary to correct the transportation deficiency is the funding responsibility of the entity that has maintenance responsibility for the facility." Furthermore, "the necessary transportation improvements to correct that deficiency shall be considered to be in place". It should be noted that the addition of Project traffic does not significantly reduce the intersection operations. For the AM Peak Hour, the required improvements to correct both the LOS and the queue lengths for the background and buildout traffic scenarios are: 1. Open the existing second WBLT lane 2. Extend the WBLT lanes to a total of 440’ of storage and deceleration length 3. Extend the WBRT lane to a total of 340’ of storage and deceleration length 4. Add overlap phases for the WBRT and NBRT movements 5. Extend the SLBT lane to a total of 425’ of storage and deceleration length 6. Extend NBRT lane to a total of 410’ of storage and deceleration length For the PM Peak Hour, the required improvements to correct both the LOS and the queue lengths for the background and buildout traffic scenarios are the above improvements for the AM peak hour plus: 7. Add second SBLT lane 8. Add third NBLT lane 9. Add fourth NB and SB thru lanes 10. Retiming Page 218 of 428 Report 23-081 3-21-24 Pinder Troutman Consulting, Inc. 4 Because these improvements are needed for the background traffic (without Project traffic), it is not the responsibility of the applicant to construct these improvements, consistent with Florida Statute 163.3180. It is acknowledged that not all of the above improvements are geometrically feasible to construct due to existing development and driveways, right-of-way constraints, and major utilities. At a minimum, it is recommended that items 1 – 5 be considered by St. Lucie County as potential feasible improvements that will decrease overall delay and queue lengths. Retiming of the signal every one to two years is recommended to correspond to the growing traffic demand. The remaining three intersections that were analyzed (including the driveway) are projected to operate at LOS C or better in the AM and PM peak hours in 2026 with and without the Project traffic. Additionally, none of the turn lanes at these intersections utilized by Project traffic are projected to be exceeded. Therefore, no improvements at these intersections are required. Roadway Link Capacity Analysis Exhibit 6 provides future peak hour traffic projections for the significantly impacted roadway links. The total traffic consists of existing traffic plus background growth and Project traffic. The roadway links are projected to operate at LOS C without the Project, and with the Project in 2026. Therefore, the roadway links meet the LOS standards. Site Access This site access is via one driveway to Silver Oaks Drive. Project driveway volumes are shown on Exhibit 7. The driveway will be constructed 350’ north of Tilton Road, in accordance with SLC LDC Section 7.05.06.2. As shown from the intersection analyses summarized on Exhibits 5A and 5B, there is projected to be minimal queuing at the Tilton Road & Silver Oaks Drive intersection, thus eliminating any conflicts between the two intersections. A left turn lane analysis was conducted to evaluate if the projected volumes meet the left turn lane volume warrant for the northbound left turn movement on Silver Oaks Drive at the Project driveway. See Exhibit 8 for the AM and PM peak hour analyses. Based on these volumes, a northbound left turn lane on Silver Oaks Drive is not warranted. Page 219 of 428 Report 23-081 3-21-24 Pinder Troutman Consulting, Inc. 5 Conclusion This analysis shows that the impacted roadway links and three intersections are projected to operate at the adopted level of service standards (LOS D or better) with the proposed development. The intersection of Prima Vista Boulevard and US 1 is considered to be a transportation deficiency and is the responsibility of the maintaining agency to make improvements according to Florida Statute 163.3180. It is recommended that the County consider some of the improvements recommended above to improve the operation of this intersection. This Project is in conformance with the requirements of Chapter V – Adequate Public Facilities, of the St. Lucie County Land Development Code. Page 220 of 428 EXHIBITS Page 221 of 428 Exhibit 1 Project Location Walton Ranch SITE Tilton Rd Si l v e r O a k s D r Le n n a r d R d Page 222 of 428 Trip Gen 23-081 3-19-24 3/19/2024 Exhibit 2 Walton Ranch Trip Generation DAILY ITE %Pass-by Land Use Code Intensity In Trips (1) Resid. Single Family 210 141 DUs 50%- 0% TOTAL - AM PEAK HOUR ITE %Pass-by Land Use Code Intensity In In Out Trips Trips (1)In Out Trips Resid. Single Family 210 141 DUs 26%27 75 102 - 0%27 75 102 TOTAL 27 75 102 - 27 75 102 PM PEAK HOUR ITE %Pass-by Land Use Code Intensity In In Out Trips Trips (1)In Out Trips Resid. Single Family 210 141 DUs 63%86 51 137 - 0%86 51 137 TOTAL 86 51 137 - 86 51 137 (1) Source: ITE Trip Generation, 11th Edition. Ln (T) = 0.92Ln (X)+2.68 Ln (T) = 0.91Ln (X)+0.12 Trip Generation Rate (1) Ln (T) = 0.94Ln (X)+0.27 Trip Generation Rate (1) Total Trips New Trips 1,384 1,384 Total Trips New Trips Total Total 1,384 1,384 Trip Generation Rate (1) Trips Trips Page 223 of 428 Exhibit 3A Project Traffic Distribution Walton Ranch Tilton Rd Si l v e r O a k s D r Le n n a r d R d Kiterman Rd 2% 98% 70% 28% 24% 28% 2% 8% 40% 20% 18% 39% 1% Ol e a n d e r D r 2% Page 224 of 428 Assign 23-081 3-19-24 3/19/2024 Exhibit 3B Walton Ranch Project Traffic Assignment AM Peak 27 In Total Significant Existing 75 Out Project Service Impact? Roadway Link Lanes Dir % Dist Trips Impact Volume (1)(Yes/No) NB 1%1 0.11%920 No SB 1%0 0.00%920 No EB 2%1 0.13%750 No WB 2%2 0.27%750 No EB 24%6 0.80%750 No WB 24%18 2.40%750 No NB 28%21 2.80%750 YES SB 28%8 1.07%750 YES NB 2%2 0.27%750 No SB 2%1 0.13%750 No EB 18%5 0.24%2100 No WB 18%14 0.67%2100 No EB 20%5 0.24%2100 No WB 20%15 0.71%2100 No EB 20%5 0.25%2000 No WB 20%15 0.75%2000 No EB 20%5 0.24%2100 No WB 20%15 0.71%2100 No EB 70%19 1.11%1710 YES WB 70%53 3.10%1710 YES NB 39%11 0.35%3170 No SB 39%29 0.91%3170 No NB 40%11 0.35%3170 No SB 40%30 0.95%3170 No NB 8%6 0.19%3170 No SB 8%2 0.06%3170 No NB 8%6 0.19%3170 No SB 8%2 0.06%3170 No NB 28%21 0.70%3020 No SB 28%8 0.26%3020 No NB 27%20 0.63%3170 No SB 27%7 0.22%3170 No (1) Based on St. Lucie County TPO 2023 Traffic Counts and Level of Service Report. See Appendix B. (2) First accessed roadway link. Oleander Ave 2L 2L 2L Oleander Ave to US 1 US 1 to Lennard Rd Ext. Kitterman Rd Prima Vista Blvd to Kitterman Rd (2)Lennard Rd Ext. Prima Vista Blvd Spanish Lakes Blvd to Prima Vista Blvd 6LD US 1 Kitterman Rd to S of Saeger Ave 6LD Rio Mar Dr to US 1 4LD US 1 to Lennard Rd (2) 4LD 4LD Naranja Ave to Rio Mar Dr 4LD Prima Vista Blvd to Airoso Blvd 2LFloresta Dr Floresta Dr to Naranja Ave Project Traffic Airoso Blvd to Floresta Dr 4LD Kitterman Rd to Midway Rd 2L 6LD Rio Mar Dr to Kitterman Rd Village Green Dr to Spanish Lakes Blvd S of Saeger Ave to Easy St 6LD Prima Vista Blvd to Rio Mar Dr 6LD 6LD Page 225 of 428 Assign 23-081 3-19-24 3/19/2024 Exhibit 3C Walton Ranch Project Traffic Assignment PM Peak 86 In Total Significant Existing 51 Out Project Service Impact? Roadway Link Lanes Dir % Dist Trips Impact Volume (1)(Yes/No) NB 1%1 0.11%920 No SB 1%1 0.11%920 No EB 2%2 0.27%750 No WB 2%1 0.13%750 No EB 24%21 2.80%750 No WB 24%12 1.60%750 No NB 28%14 1.87%750 YES SB 28%24 3.20%750 YES NB 2%1 0.13%750 No SB 2%2 0.27%750 No EB 18%15 0.71%2100 No WB 18%9 0.43%2100 No EB 20%17 0.81%2100 No WB 20%10 0.48%2100 No EB 20%17 0.85%2000 No WB 20%10 0.50%2000 No EB 20%17 0.81%2100 No WB 20%10 0.48%2100 No EB 70%60 3.51%1710 YES WB 70%36 2.11%1710 YES NB 39%34 1.07%3170 No SB 39%20 0.63%3170 No NB 40%34 1.07%3170 No SB 40%20 0.63%3170 No NB 8%4 0.13%3170 No SB 8%7 0.22%3170 No NB 8%4 0.13%3170 No SB 8%7 0.22%3170 No NB 28%14 0.46%3020 No SB 28%24 0.79%3020 No NB 27%14 0.44%3170 No SB 27%23 0.73%3170 No (1) Based on St. Lucie County TPO 2023 Traffic Counts and Level of Service Report. See Appendix B. (2) First accessed roadway link. Project Traffic 2L Kitterman Rd Oleander Ave to US 1 2L US 1 to Lennard Rd Ext. 2L Floresta Dr Prima Vista Blvd to Airoso Blvd Lennard Rd Ext. Prima Vista Blvd to Kitterman Rd (2) 2L Oleander Ave Kitterman Rd to Midway Rd 2L Prima Vista Blvd Airoso Blvd to Floresta Dr 4LD Floresta Dr to Naranja Ave 4LD Naranja Ave to Rio Mar Dr 4LD Rio Mar Dr to US 1 4LD US 1 to Lennard Rd (2) 4LD 6LD S of Saeger Ave to Easy St 6LD US 1 Village Green Dr to Spanish Lakes Blvd 6LD Spanish Lakes Blvd to Prima Vista Blvd 6LD Prima Vista Blvd to Rio Mar Dr 6LD Rio Mar Dr to Kitterman Rd 6LD Kitterman Rd to S of Saeger Ave Page 226 of 428 Trendline Growth 23-081 8-18-23 8/25/2023 Exhibit 4 Walton Ranch Historic Growth Average Trendline Annual Growth Roadway Link 2020 2021 2022 2023 2021 2022 2023 Growth Rate Lennard Rd Ext. (2)Prima Vista Blvd to Kitterman Rd 2,250 2,233 2,100 2,095 -0.8% -6.0% -0.2% -2.3% -2.76% Rio Mar Dr to US 1 26,283 17,500 23,876 23,729 -33.4% 36.4% -0.6% 0.8% -0.56% US 1 to Lennard Rd Ext. 7,400 8,500 8,508 8,721 14.9% 0.1% 2.5% 5.8% 4.79% Spanish Lakes Blvd to Prima Vista Blvd 52,500 51,500 47,867 46,801 -1.9% -7.1% -2.2% -3.7% -4.17% Prima Vista Blvd to Rio Mar Dr 36,000 39,500 35,721 35,621 9.7% -9.6% -0.3% 0.0% -1.34% 124,433 119,233 118,072 116,967 -4.2%-1.0%-0.9%-2.0%-1.97% (1) Count data from SLC TPO. See Appendix B. (2) Used Kitterman Road count from US 1 to Lennard Extension. AADT Traffic Volumes (1)Annual Growth Prima Vista Blvd US 1 Areawide Page 227 of 428 Inters summary 23-081 3-19-24 3/21/2024 Exhibit 5A Walton Ranch Intersection Analysis (1) Inters.Inters. Delay (sec)LOS Delay (sec)LOS Prima Vista Blvd / US 1 Existing (2023)48.6 D 98.6 F Future (2026)61.2 E 118.6 F Future (2026) w/Improvement 48.3 D 53.6 D Buildout (2026)63.3 E 121.8 F Buildout (2026) w/Improvement 49.9 D 54.8 D Prima Vista Blvd / Lennard Rd Ext. (2) Existing (2023)10.4 B 7.8 A Future (2026)13.1 B 9.4 A Buildout (2026)15.9 C 10.7 B Tilton Rd / Sliver Oaks Dr (2) Existing (2023)7.2 A 7.2 A Future (2026)8.1 A 8.6 A Buildout (2026)8.4 A 10.2 B Silver Oaks Dr / Driveway (3) Buildout (2026)8.7 A 8.8 A (1) See Appendix E for intersection capacity analyses. (2) Unsignalized All-way Stop intersection. (3) Unsignalized One-way Stop intersection. Highest delay reported. Intersection AM Peak Hour PM Peak Hour Page 228 of 428 Inters summary 23-081 3-19-24 3/21/2024 Exhibit 5B Walton Ranch Intersection Queues (1) Req'd Decel (ft)Existing Proposed Existing Future Future w/Imp Buildout Buildout w/Imp Existing Future Future w/Imp Buildout Buildout w/Imp Prima Vista Blvd / US 1 WBLT 145 440 440 494 727 403 846 430 998 1283 499 1388 521 WBRT 145 275 340 189 284 266 296 277 167 353 313 361 321 SBLT 185 325 425 359 404 387 408 393 576 706 417 723 425 NBRT 185 300 410 322 382 314 393 325 368 496 379 548 408 Prima Vista Blvd / Lennard Rd Ext. NBLT 145 1000*155 208 265 150 168 180 EBRT 145 1000*148 155 163 150 180 203 Tilton Rd / Sliver Oaks Dr EBLT 145 1000*148 153 158 145 173 205 SBRT 145 350**145 148 155 153 153 163 Silver Oaks Dr / Driveway NBLT 145 350**148 150 EBLT/RT N/A 300 5 5 (1) See Appendix E for intersection capacity analyses. * Indicates excessive storage exists. ** Distance from Tilton Road to Site Driveway. Indicates queue exceeds storage. Intersection / Lane AM Peak Hour PM Peak Hour Queues: 95th Percentile Storage plus Decel (ft)Storage + Taper/Decel (ft) Page 229 of 428 Links 23-081 3-19-24 3/19/2024 Exhibit 6 Walton Ranch Link Analysis Existing Total Total Service Roadway Link Lanes Dir (2023) (1)Projects 1% Grwth Total Volume %/Year Bkgd. (3)Project (2026) Volume LOS NB 183 8 6 14 11 2.00% 197 21 218 750 C SB 186 29 6 35 11 2.00% 221 8 229 750 C EB 471 49 14 63 29 2.00% 534 19 553 1,790 C WB 471 180 14 194 29 2.00% 665 53 718 1,790 C Existing Total Total Service Roadway Link Lanes Dir (2023) (1)Projects 1% Grwth Total Volume %/Year Bkgd. (3)Project (2026) Volume LOS NB 76 24 2 26 5 2.00% 102 14 116 750 C SB 103 16 3 19 6 2.00% 122 24 146 750 C EB 449 182 14 196 27 2.00% 645 60 705 1,790 C WB 449 102 14 116 27 2.00% 565 36 601 1,790 C (1) Based on St. Lucie County TPO 2023 Traffic Counts and Level of Service Report and intersection turning movement counts. See Appendix B. (2) Committed development data provided in Appendix D. Committed Dev. Analysis (2)Growth (2026) AM PEAK HOUR Committed Dev. Analysis (2)Growth (2026) PM PEAK HOUR Prima Vista Blvd to Kitterman Rd 2L (3) Background traffic includes Existing Peak Season plus the highest of Committed Development and 1% growth, or historic growth. Prima Vista Blvd US 1 to Lennard Rd Ext. 4LD Lennard Rd Ext. Prima Vista Blvd US 1 to Lennard Rd Ext. 4LD Lennard Rd Ext. Prima Vista Blvd to Kitterman Rd 2L Page 230 of 428 XX - AM PEAK HOUR (XX) - PM PEAK HOUR XXX - ADT LEGEND 27 ( 8 6 ) 75 (51) EXHIBIT 7 PROJECT DRIVEWAY VOLUMESWALTON RANCH PTC #23-081 3/19/24 N.T.S. 1,384 SITE TILTON RD SI L V E R O A K S D R Page 231 of 428 LT Lane Determination 3/21/2024 Exhibit 8 Walton Ranch Left Turn Lane Determination (1) AM Volumes PM Volumes (1) See Appendix B for traffic counts. Page 232 of 428 APPENDIX A Page 233 of 428 33 0 ' 66 0 ' 1320' 1320' LAKE 3 (2.38 AC TRACT) 15 5 - 5 0 ' X 1 1 5 ' S I N G L E F A M I L Y L O T S OS OS 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 8'' WM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM 4'' FM LAKE 2 (0.88 AC TRACT) LAKE 1 (1.23 AC TRACT) 1 PARCEL 1 PARCEL 2 LOT WETLAND (2.93 AC TRACT) WETLAND BUFFER (.67 AC TRACT) OS 2LOT 3LOT 4LOT 5LOT 6LOT 7LOT 8LOT 9LOT 10LOT 11LOT 12LOT 13LOT 14LOT 15LOT 16LOT 17LOT 18LOT 19LOT 20LOT 21LOT 22LOT 23LOT 24LOT 25LOT 26LOT 27LOT 28LOT 29LOT 30LOT 31LOT 32LOT 33LOT 34LOT 35LOT 36LOT 37LOT 38LOT 39LOT 40LOT 41LOT 42LOT 43LOT 44LOT 45LOT 46LOT 47LOT48LOT49LOT50LOT51LOT52LOT53LOT 54LOT55LOT56LOT57LOT 58LOT59LOT60LOT61LOT62LOT 63LOT64LOT65LOT66LOT 67LOT 68LOT 109LOT 110LOT 111LOT 112LOT 113LOT 114LOT 116LOT 117LOT 118LOT 119LOT 120LOT 121LOT 122LOT 127LOT 126LOT 125LOT 124LOT 123LOT 131LOT 130LOT 129LOT 128LOT 132LOT 133LOT 134LOT 135LOT 141LOT 140LOT 136LOT 137LOT 139LOT 138LOT 82LOT 83LOT84LOT85LOT86LOT 87LOT88LOT 89LOT90LOT 106LOT105LOT104LOT103LOT102LOT 101LOT100LOT 99LOT98LOT 91LOT 97LOT 92LOT 93LOT 94LOT 95LOT 96LOT 115LOT 69LOT 70LOT 81LOT 80LOT 79LOT 71LOT 72LOT 73LOT 74LOT 78LOT 77LOT 76LOT 75LOT 10' DE OS 115' 115' 20' DE20' DE 20' DE 50' LB 20' LME 350' 20' DE 20' DE 50' ROW 50' ROWREC 1 REC 2 REC 1 REC 1 REC 1 REC 1 REC 1 REC 1 REC 1 REC 4 25' BUFFER 1289' 61 0 ' 20' SECONDARY EMS STABILIZED ACCESS PROPOSED ENTRY SIGN SAVANNAHS PRESERVE STATE PARK REC 3 REC 3 EQUUS CIRCLE EQUUS CIRCLE EQUUS CIRCLE EQUUS CIRCLE EQ U U S C I R C L E EQ U U S C I R C L E ST A L L I O N L A N E TA N D E M T E R R A C E VA N N E R W A Y SILVER OAK DRIVE Mc Q U I L L E N R O A D TI L T O N R O A D SILVER OAK DRIVE 25'5' PROPOSED SW R35'R35' LIFT STATION CALL BOX 25.2' 108LOT 107LOT 1 50' Scale: 1" = 100' 0'100'300'200' North 400' MAJOR SITE PLAN by agreement in writing with the architect. Immediately report any discrepancies to the architect. SHEET COTLEUR & HEARING, INC. These drawings are the property of the architect and are not to be used for extensions or on other projects except OF DESIGNED DRAWN APPROVED JOB NUMBER REVISIONS DATE Landscape Architects Land Planners Environmental Consultants www.cotleurhearing.com 1934 Commerce Lane Suite 1 Jupiter, Florida 33458 561.747.6336 · Fax 747.1377 Lic# LC-C000239 LAH/TJB TJB LAH 2 23-0312 St . L X c L e C o X Q t \ , F l o r L G a WA L T O N R A N C H - M E R I T A G E H O M E S 03-08-24 SITE DATALEGAL DESCRIPTION KEY MAP MCQUILLEN RD TILTON RD DYER RD LE N N A R D R D SI L V E R O A K D R SH A N A S T R A I L S U S H W Y 1 SITE SAVANNAHS PRESERVE STATE PARK LEGEND LB LANDSCAPE BUFFER ROW RIGHT OF WAY REC OPEN SPACE/RECREATION SW SIDEWALK DE DRAINAGE EASEMENT UE UTILITY EASEMENT TRAFFIC STATEMENTDRAINAGE STATEMENTENVIRONMENTAL STATEMENT ENVIRONMENTAL: AQUATIC RESEARCH MONITORING, EQUIPMENT & DEPLOYMENT, LLC. PO BOX 1421 STUART, FL 34995-1421 772.626.9005 CIVIL ENGINEER: KIMLEY-HORN & ASSOCIATES, INC. 445 24 THE STREET, SUITE 200 VERO BEACH, FL 32960 772.794.4099 OWNER: MERITAGE HOMES OF FLORIDA INC. 1400 CENTREPARK BLVD., SUITE 1000 WEST PALM BEACH, FL 33401 561.983.0675 LANDSCAPE ARCHITECT/PLANNER: COTLEUR & HEARING, INC. 1934 COMMERCE LANE, SUITE 1 JUPITER, FL 33458 561.747.6336 PROJECT TEAM SURVEYOR: CAULFIELD & WHEELER, INC. 7900 GLADES ROAD, SUITE 100 BOCA RATON, FLORIDA 33433 561.392.1991 TRAFFIC ENGINEER: PINDER TROUTMAN CONSULTING, INC. 601 HERITAGE DRIVE, SUITE 493 JUPITER, FL 33458 561.296.9698 THE ITE TRIP GENERATION MANUAL, 11TH EDITION, LAND USE CODE 210 (RESIDENTIAL SINGLE FAMILY) WAS USED TO DETERMINE EXPECTED DAILY AND PEAK HOUR TRIPS FOR THE PROPOSED PROJECT. TRIP GENERATION AM PEAK HOUR PM PEAK HOUR LAND USE INTENSITY DAILY IN OUT TOTAL IN OUT TOTAL RESIDENTIAL 151 DUS 1,474 28 80 108 92 54 146 DEVELOPMENT OF THE PROPOSED WALTON RANCH COMMUNITY HAS BEEN DESIGNED TO INCORPORATE THE SITE'S NATURAL FEATURES TO THE GREATEST POSSIBLE EXTENTS WHILE MAINTAINING REASONABLE USABILITY OF THE SITE. THIS INCLUDES MINIMAL WETLAND IMPACTS WITH A MITIGATION PLAN THAT INCORPORATES WETLAND ENHANCEMENT AND PERPETUAL PRESERVATION INTO THE PROPOSED COMMUNITY DESIGN. NO LISTED SPECIES NESTING, DENNING NOR ROOSTING IS OCCURRING ON THE SUBJECT PROPERTY THEREBY NO LISTED SPECIES IMPACTS ARE PROPOSED NOR ANTICIPATED FROM CONSTRUCTION OF THE PROJECT. LOTS 1, 2, 3, 15 AND 16, BLOCK 2, PLAT NO. 1 SAINT LUCIE GARDENS SECTION 23, TOWNSHIP 36 SOUTH, RANGE 40 EAST, ACCORDING TO THE MAP OR PLAT THEREOF, RECORDED IN PLAT BOOK 1, PAGE(S) 35, PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. CONTAINING 45.733 ACRES MORE OR LESS. SAID LANDS SITUATE IN ST. LUCIE COUNTY, FLORIDA. SUBJECT TO EASEMENTS, RESTRICTIONS, RESERVATIONS, COVENANTS, AND RIGHTS-OF-WAY OF RECORD. SILVER OAKS REALIGNMENT Page 234 of 428 APPENDIX B Page 235 of 428 Roadway Name Location AADT Volume Traffic Counts and Level of Service Report 2023 LOS V/C PM Pk Hr Pk Dir Pk Hr Service Capacity AM Pk Hr Pk Dir V/C LOS Volume 1,300 60 60 25TH ST to OKEECHOBEE RDDELAWARE AVE 0.05C 0.05C 1,220 11,500 645 613 OKEECHOBEE RD to 13TH STDELAWARE AVE 0.78D 0.82D 790 7,451 405 386 13TH ST to 10TH STDELAWARE AVE 0.52D 0.54D 750 7,451 405 386 10TH ST to 7TH STDELAWARE AVE 0.64D 0.68D 600 6,900 447 402 7TH ST to US 1DELAWARE AVE 0.54D 0.60D 750 12,553 740 731 CASHMERE BLVD to TORINO PKWYEAST TORINO PKWY 0.88C 0.89C 830 15,500 1,016 987 TORINO PKWY to MIDWAY RDEAST TORINO PKWY 1.12F 1.16F 880 7,207 399 506 US 1 to BUCHANAN DREASY ST 0.68D 0.53D 750 7,207 399 506 BUCHANAN DR to YUCCA DREASY ST 0.94D 0.74D 540 11,153 513 516 JENKINS RD to MCNEIL RDEDWARDS RD 0.82C 0.81C 630 11,153 513 516 MCNEIL RD to SELVITZ RDEDWARDS RD 0.74C 0.73C 700 15,291 769 782 SELVITZ RD to 25TH STEDWARDS RD 0.89C 0.87C 880 17,013 827 828 25TH ST to SUNRISE BLVDEDWARDS RD 0.51D 0.51D 1,630 15,984 793 773 SUNRISE BLVD to OLEANDER AVEEDWARDS RD 0.47D 0.49D 1,630 9,722 535 467 OLEANDER AVE to US 1EDWARDS RD 0.29C 0.33C 1,630 1,700 89 103 OLEANDER AVE to US 1FARMER'S MARKET RD 0.14C 0.12C 750 14,500 975 817 OAKLYN ST to PORT ST LUCIE BLVDFLORESTA DR 0.89C 1.06F 920 14,098 960 851 THORNHILL DR to CROSSTOWN PKWYFLORESTA DR 0.97D 1.09F 880 14,098 960 851 PORT ST LUCIE BLVD to THORNHILL DRFLORESTA DR 0.97D 1.09F 880 12,183 675 619 CROSSTOWN PKWY to PRIMA VISTA BLVDFLORESTA DR 0.67C 0.73C 920 10,748 594 655 PRIMA VISTA BLVD to AIROSO BLVDFLORESTA DR 0.71C 0.65C 920 4,750 341 363 SELVITZ RD to BAYSHORE BLVDFLORESTA DR 0.58C 0.54C 630 4,750 341 363 AIROSO BLVD to SELVITZ RDFLORESTA DR 0.41C 0.39C 880 47,500 2,270 2,270 MARTIN C.L. to BECKER RDFLORIDA'S TURNPIKE 0.75C 0.75C 3,020 55,100 2,791 2,791 PORT ST LUCIE BLVD to OKEECHOBEE RDFLORIDA'S TURNPIKE 0.92C 0.92C 3,020 43,200 2,157 2,157 OKEECHOBEE RD to INDIAN RIVER C.L.FLORIDA'S TURNPIKE 1.28C 1.28C 1,680 3,200 217 223 INDRIO RD to EMERSON AVEFT PIERCE BLVD 0.41C 0.40C 540 2,780 214 204 OLEANDER AVE to US 1GARDENIA AVE 0.27C 0.28C 750 49,323 2,408 2,408 W OF I-95 to E OF I-95GATLIN BLVD 0.76C 0.76C 3,170 6 * Volumes shown were adjusted using FDOT Seasonal Factors * AADT = Annual Average Daily Traffic Page 236 of 428 Roadway Name Location AADT Volume Traffic Counts and Level of Service Report 2023 LOS V/C PM Pk Hr Pk Dir Pk Hr Service Capacity AM Pk Hr Pk Dir V/C LOS Volume 3,200 234 253 ANGLE RD to JUANITA AVEKEEN RD 0.40C 0.37C 630 3,200 234 253 JUANITA AVE to ST LUCIE BLVDKEEN RD 0.40C 0.37C 630 9,383 472 472 OKEECHOBEE RD to CROSSROADS PKWYKINGS HWY 0.54C 0.54C 880 9,383 472 472 CROSSROADS PKWY to GRAHAM RDKINGS HWY 0.67C 0.67C 700 7,181 361 361 GRAHAM RD to PICOS RDKINGS HWY 0.52C 0.52C 700 7,181 361 361 PICOS RD to ORANGE AVEKINGS HWY 0.41C 0.41C 880 15,247 767 767 ORANGE AVE to ANGLE RDKINGS HWY 0.83C 0.83C 920 11,202 547 547 ANGLE RD to ST LUCIE BLVDKINGS HWY 0.62C 0.62C 880 13,787 673 673 ST LUCIE BLVD to INDRIO RDKINGS HWY 0.77C 0.77C 880 2,581 150 139 EDWARDS RD to 35TH STKIRBY LOOP RD 0.22C 0.24C 630 2,600 167 136 OLEANDER AVE to US 1KITTERMAN RD 0.18C 0.22C 750 2,095 123 128 US 1 to LENNARD EXTKITTERMAN RD 0.17C 0.16C 750 20,570 1,234 1,170 US 1 to MARIPOSA AVELENNARD RD 0.68D 0.72D 1,710 20,570 1,234 1,170 MARIPOSA AVE to MELALEUCA BLVDLENNARD RD 0.68D 0.72D 1,710 20,570 1,234 1,170 MELALEUCA BLVD to JENNINGS RDLENNARD RD 0.72D 0.76D 1,630 20,570 1,234 1,170 JENNINGS RD to HILLMOOR DRLENNARD RD 0.68D 0.72D 1,710 20,570 1,234 1,170 HILLMOOR DR to TIFFANY AVELENNARD RD 0.68D 0.72D 1,710 7,365 403 389 TIFFANY AVE to WALTON RDLENNARD RD 0.23C 0.24C 1,710 3,748 259 246 WALTON RD to S OF SAVANNA CLUB BLVDLENNARD RD 0.31C 0.33C 790 9,700 612 553 VETERANS MEMORIAL PKWY to MORNINGSIDE BLVDLYNGATE DR 0.60C 0.67C 920 9,700 612 553 MORNINGSIDE BLVD to US 1LYNGATE DR 0.60C 0.67C 920 7,300 568 541 LENNARD RD to HALLAHAN STMARIPOSA AVE 0.62C 0.65C 880 364 27 25 WILLIAMS RD to MIDWAY RDMCCARTY RD 0.05C 0.05C 540 431 37 37 MIDWAY RD to OKEECHOBEE RDMCCARTY RD 0.07C 0.07C 540 4,900 307 298 OKEECHOBEE RD to KIRBY LOOP RDMCNEIL RD 0.38C 0.39C 790 4,900 307 298 KIRBY LOOP RD to EDWARDS RDMCNEIL RD 0.55D 0.57D 540 10,710 630 601 LENNARD RD to GREEN RIVER PKWYMELALEUCA BLVD 0.65C 0.69C 920 25,000 1,245 1,298 EAST TORINO PKWY to MILNER DRMIDWAY RD 1.48F 1.42F 880 25,000 1,245 1,298 MILNER DR to W OF SELVITZ RDMIDWAY RD 1.64F 1.58F 790 9 * Volumes shown were adjusted using FDOT Seasonal Factors * AADT = Annual Average Daily Traffic Page 237 of 428 Roadway Name Location AADT Volume Traffic Counts and Level of Service Report 2023 LOS V/C PM Pk Hr Pk Dir Pk Hr Service Capacity AM Pk Hr Pk Dir V/C LOS Volume 9,733 490 490 FLORIDA'S TURNPIKE to KINGS HWYOKEECHOBEE RD 0.23C 0.23C 2,100 23,734 1,195 1,195 KINGS HWY to CROSSROADS PKWYOKEECHOBEE RD 0.28C 0.28C 4,240 26,375 1,327 1,327 CROSSROADS PKWY to I-95OKEECHOBEE RD 0.31C 0.31C 4,240 32,142 1,569 1,569 I-95 to JENKINS RDOKEECHOBEE RD 0.37C 0.37C 4,240 32,142 1,569 1,569 JENKINS RD to MCNEIL RDOKEECHOBEE RD 0.39C 0.39C 4,040 31,230 1,524 1,524 MCNEIL RD to VIRGINIA AVEOKEECHOBEE RD 0.48C 0.48C 3,170 15,500 802 791 VIRGINIA AVE to HARTMAN RDOKEECHOBEE RD 0.38C 0.38C 2,100 15,500 802 791 HARTMAN RD to 35TH STOKEECHOBEE RD 0.49D 0.49D 1,630 16,500 859 822 35TH ST to 33RD STOKEECHOBEE RD 0.50D 0.53D 1,630 16,500 859 822 33RD ST to 25TH STOKEECHOBEE RD 0.50D 0.53D 1,630 12,000 695 616 25TH ST to GEORGIA AVEOKEECHOBEE RD 0.38C 0.43C 1,630 12,000 695 616 GEORGIA AVE to DELAWARE AVEOKEECHOBEE RD 0.36C 0.41C 1,710 830 129 123 US 1 to SR A1A NORTHOLD DIXIE HWY 0.16C 0.16C 790 1,753 82 82 SR A1A NORTH to ST LUCIE BLVDOLD DIXIE HWY 0.11C 0.11C 750 2,125 172 126 ST LUCIE BLVD to INDRIO RDOLD DIXIE HWY 0.16C 0.22C 790 1,340 63 63 INDRIO RD to INDIAN RIVER C.L.OLD DIXIE HWY 0.07C 0.07C 870 2,970 172 194 BEACH AVE to KITTERMAN RDOLEANDER AVE 0.36C 0.32C 540 6,162 358 358 KITTERMAN RD to MIDWAY RDOLEANDER AVE 0.48C 0.48C 750 6,400 362 365 MIDWAY RD to WEATHERBEE RDOLEANDER AVE 0.49C 0.48C 750 6,400 362 365 WEATHERBEE RD to BELL AVEOLEANDER AVE 0.68D 0.67D 540 12,703 613 581 BELL AVE to FARMER'S MARKET RDOLEANDER AVE 1.08F 1.14F 540 12,703 613 581 FARMER'S MARKET RD to EDWARDS RDOLEANDER AVE 0.78D 0.82D 750 9,907 601 500 EDWARDS RD to WISTERIA AVEOLEANDER AVE 0.67D 0.80D 750 9,907 601 500 WISTERIA AVE to GARDENIA AVEOLEANDER AVE 0.93D 1.11F 540 9,907 601 500 GARDENIA AVE to VIRGINIA AVEOLEANDER AVE 0.63D 0.76D 790 5,500 309 320 VIRGINIA AVE to SUNRISE BLVDOLEANDER AVE 0.53D 0.52D 600 5,195 303 289 OKEECHOBEE C.L. to SNEED RDORANGE AVE 0.43C 0.45C 670 5,195 303 289 SNEED RD to HEADER CANAL RDORANGE AVE 0.43C 0.45C 670 5,195 303 289 HEADER CANAL RD to SHINN RDORANGE AVE 0.43C 0.45C 670 11 * Volumes shown were adjusted using FDOT Seasonal Factors * AADT = Annual Average Daily Traffic Page 238 of 428 Roadway Name Location AADT Volume Traffic Counts and Level of Service Report 2023 LOS V/C PM Pk Hr Pk Dir Pk Hr Service Capacity AM Pk Hr Pk Dir V/C LOS Volume 48,937 2,389 2,389 DEL RIO BLVD to CAMEO BLVDPORT ST LUCIE BLVD 0.75C 0.75C 3,170 48,937 2,389 2,389 CAMEO BLVD to FLORIDA'S TURNPIKEPORT ST LUCIE BLVD 0.79C 0.79C 3,020 48,937 2,389 2,389 FLORIDA'S TURNPIKE to BAYSHORE BLVDPORT ST LUCIE BLVD 0.75C 0.75C 3,170 47,450 2,316 2,316 BAYSHORE BLVD to AIROSO BLVDPORT ST LUCIE BLVD 0.77C 0.77C 3,020 48,434 2,365 2,365 AIROSO BLVD to FLORESTA DRPORT ST LUCIE BLVD 0.78C 0.78C 3,020 56,157 2,742 2,742 FLORESTA DR to VETERANS MEMORIAL PKWYPORT ST LUCIE BLVD 0.91C 0.91C 3,020 37,906 1,850 1,850 VETERANS MEMORIAL PKWY to MORNINGSIDE BLVDPORT ST LUCIE BLVD 0.61C 0.61C 3,020 37,650 1,838 1,838 MORNINGSIDE BLVD to US 1PORT ST LUCIE BLVD 0.58C 0.58C 3,170 24,629 1,083 1,188 BAYSHORE BLVD to AIROSO BLVDPRIMA VISTA BLVD 0.57C 0.52C 2,100 24,157 1,027 1,018 AIROSO BLVD to FLORESTA DRPRIMA VISTA BLVD 0.49C 0.49C 2,100 29,500 1,669 1,498 FLORESTA DR to NARANJA AVEPRIMA VISTA BLVD 0.71C 0.80C 2,100 29,500 1,669 1,498 NARANJA AVE to RIO MAR DRPRIMA VISTA BLVD 0.75C 0.84C 2,000 23,729 1,236 1,117 RIO MAR DR to US 1PRIMA VISTA BLVD 0.53C 0.59C 2,100 8,721 471 449 US 1 to LENNARD RDPRIMA VISTA BLVD 0.26C 0.28C 1,710 2,500 147 158 MARTIN C.L. to BECKER RDRANGE LINE RD 0.15B 0.14B 1,080 2,500 147 158 BECKER RD to 2 MI S OF GLADES CUT-OFF RDRANGE LINE RD 0.15B 0.14B 1,080 2,500 147 158 2 MI S OF GLADES CUT-OFF RD to GLADES CUT-OF...RANGE LINE RD 0.15B 0.14B 1,080 5,600 343 408 PRIMA VISTA BLVD to BEACH AVERIO MAR DR 0.54D 0.46C 750 5,600 343 408 BEACH AVE to US 1RIO MAR DR 0.52D 0.43C 790 4,956 229 229 APRICOT RD to GATLIN BLVDROSSER BLVD 0.25C 0.25C 920 4,956 229 229 PAAR DR to APRICOT RDROSSER BLVD 0.21B 0.21B 1,070 3,600 263 214 GATLIN BLVD to GALIANO RDSAVAGE BLVD 0.23C 0.29C 920 2,100 130 135 US 1 to INDIAN RIVER DRSAVANNAH RD 0.25C 0.24C 540 11,057 984 884 BECKER RD to PAAR DRSAVONA BLVD 1.12F 1.25F 790 11,057 984 884 PAAR DR to GATLIN BLVDSAVONA BLVD 1.18F 1.31F 750 14,406 668 705 GATLIN BLVD to CALIFORNIA BLVDSAVONA BLVD 0.89D 0.85D 790 9,447 437 437 BAYSHORE BLVD to ST JAMES BLVDSELVITZ RD 0.58D 0.58D 750 9,447 437 437 ST JAMES BLVD to MIDWAY RDSELVITZ RD 0.58D 0.58D 750 10,313 604 609 MIDWAY RD to GLADES CUT-OFF RDSELVITZ RD 0.87C 0.86C 700 13 * Volumes shown were adjusted using FDOT Seasonal Factors * AADT = Annual Average Daily Traffic Page 239 of 428 Roadway Name Location AADT Volume Traffic Counts and Level of Service Report 2023 LOS V/C PM Pk Hr Pk Dir Pk Hr Service Capacity AM Pk Hr Pk Dir V/C LOS Volume 3,611 218 230 MIDWAY RD to BELL AVESUNRISE BLVD 0.43C 0.40C 540 4,050 267 270 BELL AVE to EDWARDS RDSUNRISE BLVD 0.36C 0.36C 750 7,600 586 511 EDWARDS RD to CORTEZ BLVDSUNRISE BLVD 0.85D 0.98D 600 7,600 586 511 CORTEZ BLVD to VIRGINIA AVESUNRISE BLVD 0.68D 0.78D 750 6,700 419 416 VIRGINIA AVE to OLEANDER AVESUNRISE BLVD 0.56D 0.56D 750 5,053 291 357 OLEANDER AVE to 7TH STSUNRISE BLVD 0.23C 0.19C 1,540 5,053 291 357 7TH ST to US 1SUNRISE BLVD 0.21C 0.17C 1,710 17,532 992 904 US 1 to HILLMOOR DRTIFFANY AVE 0.43C 0.47C 2,100 17,532 992 904 HILLMOOR DR to VILLAGE GREEN DRTIFFANY AVE 0.43C 0.47C 2,100 4,227 205 199 VILLAGE GREEN DR to LENNARD RDTIFFANY AVE 0.10C 0.10C 2,100 7,020 449 410 CASHMERE BLVD to CALIFORNIA BLVDTORINO PKWY 0.65C 0.71C 630 4,984 329 269 CALIFORNIA BLVD to EAST TORINO PKWYTORINO PKWY 0.43C 0.52C 630 7,590 794 770 COMMUNITY BLVD to VILLAGE PKWYTRADITION PKWY 0.45C 0.46D 1,710 46,500 2,338 2,116 VILLAGE PKWY to W OF I-95TRADITION PKWY 0.67C 0.74C 3,170 9,314 610 551 DARWIN BLVD to PORT ST LUCIE BLVDTULIP BLVD 0.70D 0.77D 790 10,813 605 647 PORT ST LUCIE BLVD to PAAR DRTULIP BLVD 0.82D 0.77D 790 10,813 605 647 PAAR DR to DARWIN BLVDTULIP BLVD 0.82D 0.77D 790 4,920 TURNPIKE FEEDER RD SB RAMP to US 1TURNPIKE FEEDER RD BB 660 11,335 553 553 INDIAN PINES BLVD to TURNPIKE FEEDER RD SB R...TURNPIKE FEEDER RD 0.64C 0.64C 870 13,204 644 644 INDRIO RD to INDIAN PINES BLVDTURNPIKE FEEDER RD 0.74C 0.74C 870 47,386 2,354 2,354 MARTIN C.L. to LENNARD RDUS 1 0.56C 0.56C 4,240 47,386 2,354 2,354 LENNARD RD to PORT ST LUCIE BLVDUS 1 0.58C 0.58C 4,040 32,450 1,612 1,612 PORT ST LUCIE BLVD to JENNINGS RDUS 1 0.53C 0.53C 3,020 32,450 1,612 1,612 JENNINGS RD to TIFFANY AVEUS 1 0.53C 0.53C 3,020 32,450 1,612 1,612 TIFFANY AVE to WALTON RDUS 1 0.53C 0.53C 3,020 44,760 2,223 2,223 WALTON RD to VILLAGE GREEN DRUS 1 0.74C 0.74C 3,020 46,801 2,325 2,325 VILLAGE GREEN DR to SPANISH LAKES BLVDUS 1 0.73C 0.73C 3,170 46,801 2,325 2,325 SPANISH LAKES BLVD to PRIMA VISTA BLVDUS 1 0.73C 0.73C 3,170 35,621 1,769 1,769 PRIMA VISTA BLVD to RIO MAR DRUS 1 0.56C 0.56C 3,170 15 * Volumes shown were adjusted using FDOT Seasonal Factors * AADT = Annual Average Daily Traffic Page 240 of 428 Roadway Name Location AADT Volume Traffic Counts and Level of Service Report 2023 LOS V/C PM Pk Hr Pk Dir Pk Hr Service Capacity AM Pk Hr Pk Dir V/C LOS Volume 31,668 1,573 1,573 RIO MAR DR to KITTERMAN RDUS 1 0.50C 0.50C 3,170 31,668 1,573 1,573 KITTERMAN RD to S OF SAEGER AVEUS 1 0.52C 0.52C 3,020 31,668 1,573 1,573 S OF SAEGER AVE to EASY STUS 1 0.50C 0.50C 3,170 29,229 1,452 1,452 EASY ST to MIDWAY RDUS 1 0.46C 0.46C 3,170 30,634 1,522 1,522 MIDWAY RD to WEATHERBEE RDUS 1 0.73C 0.73C 2,100 30,634 1,522 1,522 WEATHERBEE RD to FARMER'S MARKET RDUS 1 0.76C 0.76C 2,000 30,634 1,522 1,522 FARMER'S MARKET RD to EDWARDS RDUS 1 0.76C 0.76C 2,000 27,434 1,363 1,363 EDWARDS RD to SAVANNAH RDUS 1 0.68C 0.68C 2,000 27,434 1,363 1,363 GARDENIA AVE to VIRGINIA AVEUS 1 0.68C 0.68C 2,000 27,434 1,363 1,363 SAVANNAH RD to GARDENIA AVEUS 1 0.68C 0.68C 2,000 24,778 1,231 1,231 VIRGINIA AVE to OHIO AVEUS 1 0.62C 0.62C 2,000 24,778 1,231 1,231 OHIO AVE to GEORGIA AVEUS 1 0.76D 0.76D 1,630 27,037 1,343 1,343 GEORGIA AVE to DELAWARE AVEUS 1 0.82D 0.82D 1,630 28,871 1,434 1,434 DELAWARE AVE to CITRUS AVEUS 1 0.88D 0.88D 1,630 24,609 1,222 1,222 CITRUS AVE to ORANGE AVEUS 1 0.75D 0.75D 1,630 28,871 1,434 1,434 ORANGE AVE to AVENUE AUS 1 0.88D 0.88D 1,630 28,871 1,434 1,434 AVENUE A to AE BACKUS AVEUS 1 0.88D 0.88D 1,630 28,871 1,434 1,434 AE BACKUS AVE to AVENUE DUS 1 0.88D 0.88D 1,630 28,871 1,434 1,434 AVENUE D to SR A1A SOUTHUS 1 0.88D 0.88D 1,630 29,000 1,442 1,439 SR A1A SOUTH to AVENUE HUS 1 0.69C 0.69C 2,100 29,000 1,442 1,439 AVENUE H to OLD DIXIE HWYUS 1 0.72C 0.72C 2,000 27,651 1,373 1,373 OLD DIXIE HWY to AVENUE OUS 1 0.69C 0.69C 2,000 27,651 1,373 1,373 AVENUE O to SR A1A NORTHUS 1 0.65C 0.65C 2,100 19,670 977 977 SR A1A NORTH to JUANITA AVEUS 1 0.47C 0.47C 2,100 19,670 977 977 JUANITA AVE to ST LUCIE BLVDUS 1 0.47C 0.47C 2,100 19,097 948 948 ST LUCIE BLVD to 25TH STUS 1 0.45C 0.45C 2,100 19,097 948 948 25TH ST to INDRIO RDUS 1 0.45C 0.45C 2,100 24,070 1,195 1,195 INDRIO RD to TURNPIKE FEEDER RDUS 1 0.57C 0.57C 2,100 24,070 1,195 1,195 TURNPIKE FEEDER RD to INDIAN RIVER C.L.US 1 0.57C 0.57C 2,100 16 * Volumes shown were adjusted using FDOT Seasonal Factors * AADT = Annual Average Daily Traffic Page 241 of 428 Roadway Name Location Volume LOS V/C PM Pk Hr Pk Dir Pk Hr Service Capacity AM Pk Hr Pk Dir V/C LOS Volume STATION ID Last Physical Count Year Traffic Counts and Level of Service Report 2022 2022 AADT * 8,819 INDRIO RD to RUSSOS RDJOHNSTON RD 1,070 500 135 C 0.467 501 C 0.468 2019 8,819 RUSSOS RD to INDIAN RIVER C.L.JOHNSTON RD 1,070 500 135 C 0.467 501 C 0.468 2019 2,900 53RD ST to 25TH STJUANITA AVE 750 187 122 C 0.249 171 C 0.228 2022 4,800 25TH ST to US 1JUANITA AVE 750 268 120 C 0.357 263 C 0.351 2022 3,008 ANGLE RD to JUANITA AVEKEEN RD 630 181 129 C 0.287 212 C 0.337 2018 3,008 JUANITA AVE to ST LUCIE BLVDKEEN RD 630 181 129 C 0.287 212 C 0.337 2018 9,000 OKEECHOBEE RD to CROSSROADS PKWYKINGS HWY 880 436 940757 C 0.495 446 C 0.507 2020 9,000 CROSSROADS PKWY to GRAHAM RDKINGS HWY 700 436 940757 C 0.623 446 C 0.637 2020 7,762 GRAHAM RD to PICOS RDKINGS HWY 700 395 940076 C 0.564 379 C 0.541 2020 7,762 PICOS RD to ORANGE AVEKINGS HWY 880 395 940076 C 0.449 379 C 0.431 2020 16,024 ORANGE AVE to ANGLE RDKINGS HWY 920 794 940077 C 0.863 799 C 0.868 2020 11,387 ANGLE RD to ST LUCIE BLVDKINGS HWY 880 607 940751 C 0.69 611 C 0.694 2020 13,805 ST LUCIE BLVD to INDRIO RDKINGS HWY 880 822 940006 C 0.934 772 C 0.877 2020 2,686 EDWARDS RD to 35TH STKIRBY LOOP RD 630 156 677 C 0.248 144 C 0.229 2020 3,641 OLEANDER AVE to US 1KITTERMAN RD 750 239 124 C 0.319 217 C 0.289 2018 2,100 US 1 to LENNARD EXTKITTERMAN RD 750 120 678 C 0.16 121 C 0.161 2022 18,000 US 1 to MARIPOSA AVELENNARD RD 1,710 927 325 D 0.542 957 D 0.56 2022 18,000 MARIPOSA AVE to MELALEUCA BLVDLENNARD RD 1,710 927 325 D 0.542 957 D 0.56 2022 18,000 MELALEUCA BLVD to JENNINGS RDLENNARD RD 1,630 927 325 D 0.569 957 D 0.587 2022 18,000 JENNINGS RD to HILLMOOR DRLENNARD RD 1,710 927 325 D 0.542 957 D 0.56 2022 18,000 HILLMOOR DR to TIFFANY AVELENNARD RD 1,710 927 325 D 0.542 957 D 0.56 2022 9,000 TIFFANY AVE to WALTON RDLENNARD RD 1,710 470 323 C 0.275 477 C 0.279 2022 3,761 WALTON RD to S OF SAVANNA CLUB BLVDLENNARD RD 790 260 679 C 0.329 247 C 0.313 2020 10,911 VETERANS MEMORIAL PKWY to MORNINGSIDE BLVDLYNGATE DR 920 683 306 C 0.742 726 C 0.789 2019 10,911 MORNINGSIDE BLVD to US 1LYNGATE DR 920 683 306 C 0.742 726 C 0.789 2019 10 * Volumes shown were adjusted using FDOT Seasonal Factors * AADT = Annual Average Daily Traffic (volumes for both directions where applicable) * Counts with an ID format of 6 digits have data extracted from FDOT count stations. * NOTE: A six digit number in the "STATION ID" column identifies segment counted by FDOT * NOTE: If the Last Count Year is older than the year of the report, the AADT is projected from historical traffic count data. Page 242 of 428 Roadway Name Location Volume LOS V/C PM Pk Hr Pk Dir Pk Hr Service Capacity AM Pk Hr Pk Dir V/C LOS Volume STATION ID Last Physical Count Year Traffic Counts and Level of Service Report 2022 2022 AADT * 38,628 VETERANS MEMORIAL PKWY to MORNINGSIDE BLVDPORT ST LUCIE BLVD 3,020 2,568 940776 C 0.85 2,278 C 0.754 2020 39,257 MORNINGSIDE BLVD to US 1PORT ST LUCIE BLVD 3,170 3,013 945072 C 0.95 1,879 C 0.593 2020 24,567 BAYSHORE BLVD to AIROSO BLVDPRIMA VISTA BLVD 2,100 1,080 314 C 0.514 1,185 C 0.564 2020 24,142 AIROSO BLVD to FLORESTA DRPRIMA VISTA BLVD 2,100 1,112 150 C 0.53 1,042 C 0.496 2021 34,321 FLORESTA DR to NARANJA AVEPRIMA VISTA BLVD 2,100 1,975 148 C 0.94 1,879 C 0.895 2020 34,321 NARANJA AVE to RIO MAR DRPRIMA VISTA BLVD 2,000 1,975 148 D 0.988 1,879 C 0.94 2020 23,876 RIO MAR DR to US 1PRIMA VISTA BLVD 2,100 1,160 146 C 0.552 1,059 C 0.504 2021 8,508 US 1 to LENNARD RDPRIMA VISTA BLVD 1,710 460 699 C 0.269 438 C 0.256 2020 1,741 MARTIN C.L. to BECKER RDRANGE LINE RD 1,080 117 145 B 0.108 116 B 0.107 2018 1,741 BECKER RD to 2 MI S OF GLADES CUT-OFF RDRANGE LINE RD 1,080 117 145 B 0.108 116 B 0.107 2018 1,741 2 MI S OF GLADES CUT-OFF RD to GLADES CUT-OF...RANGE LINE RD 1,080 117 145 B 0.108 116 B 0.107 2018 5,726 PRIMA VISTA BLVD to BEACH AVERIO MAR DR 750 354 147 C 0.472 372 D 0.496 2019 5,726 BEACH AVE to US 1RIO MAR DR 790 354 147 C 0.448 372 C 0.471 2019 4,020 APRICOT RD to GATLIN BLVDROSSER BLVD 920 185 948510 C 0.201 185 C 0.201 2020 4,020 PAAR DR to APRICOT RDROSSER BLVD 1,070 185 948510 B 0.173 185 B 0.173 2020 10,556 BECKER RD to PAAR DRSAVONA BLVD 790 939 236 F 1.189 844 F 1.068 2020 10,556 PAAR DR to GATLIN BLVDSAVONA BLVD 750 939 236 F 1.252 844 F 1.125 2020 14,200 GATLIN BLVD to CALIFORNIA BLVDSAVONA BLVD 790 659 702 D 0.834 695 D 0.88 2020 4,244 GATLIN BLVD to GALIANO RDSAVAGE BLVD 920 280 168 C 0.304 225 C 0.245 2018 2,157 US 1 to INDIAN RIVER DRSAVANNAH RD 540 153 514 C 0.283 151 C 0.28 2018 9,240 BAYSHORE BLVD to ST JAMES BLVDSELVITZ RD 750 450 948501 D 0.6 450 D 0.6 2020 9,240 ST JAMES BLVD to MIDWAY RDSELVITZ RD 750 450 948501 D 0.6 450 D 0.6 2020 10,073 MIDWAY RD to GLADES CUT-OFF RDSELVITZ RD 700 590 703 C 0.843 594 C 0.849 2020 14,479 GLADES CUT-OFF RD to EDWARDS RDSELVITZ RD 790 767 704 D 0.971 764 D 0.967 2020 450 MIDWAY RD to OKEECHOBEE RDSHINN RD 580 29 705 C 0.05 28 C 0.048 2022 15 * Volumes shown were adjusted using FDOT Seasonal Factors * AADT = Annual Average Daily Traffic (volumes for both directions where applicable) * Counts with an ID format of 6 digits have data extracted from FDOT count stations. * NOTE: A six digit number in the "STATION ID" column identifies segment counted by FDOT * NOTE: If the Last Count Year is older than the year of the report, the AADT is projected from historical traffic count data. Page 243 of 428 Roadway Name Location Volume LOS V/C PM Pk Hr Pk Dir Pk Hr Service Capacity AM Pk Hr Pk Dir V/C LOS Volume STATION ID Last Physical Count Year Traffic Counts and Level of Service Report 2022 2022 AADT * 28,759 JENNINGS RD to TIFFANY AVEUS 1 3,020 1,426 945070 C 0.472 1,513 C 0.501 2020 28,759 TIFFANY AVE to WALTON RDUS 1 3,020 1,426 945070 C 0.472 1,513 C 0.501 2020 44,322 WALTON RD to VILLAGE GREEN DRUS 1 3,020 2,480 945150 C 0.821 2,223 C 0.736 2020 47,867 VILLAGE GREEN DR to SPANISH LAKES BLVDUS 1 3,170 2,714 940265 C 0.856 2,541 C 0.802 2020 47,867 SPANISH LAKES BLVD to PRIMA VISTA BLVDUS 1 3,170 2,714 940265 C 0.856 2,541 C 0.802 2020 35,721 PRIMA VISTA BLVD to RIO MAR DRUS 1 3,170 1,744 940264 C 0.55 1,717 C 0.542 2020 31,340 RIO MAR DR to KITTERMAN RDUS 1 3,170 1,673 940266 C 0.528 1,515 C 0.478 2020 31,340 KITTERMAN RD to S OF SAEGER AVEUS 1 3,020 1,673 940266 C 0.554 1,515 C 0.502 2020 31,340 S OF SAEGER AVE to EASY STUS 1 3,170 1,673 940266 C 0.528 1,515 C 0.478 2020 28,584 EASY ST to MIDWAY RDUS 1 3,170 1,455 945156 C 0.459 1,414 C 0.446 2020 30,541 MIDWAY RD to WEATHERBEE RDUS 1 2,100 1,450 940012 C 0.69 1,468 C 0.699 2020 30,541 WEATHERBEE RD to FARMER'S MARKET RDUS 1 2,000 1,450 940012 C 0.725 1,468 C 0.734 2020 30,541 FARMER'S MARKET RD to EDWARDS RDUS 1 2,000 1,450 940012 C 0.725 1,468 C 0.734 2020 25,463 EDWARDS RD to SAVANNAH RDUS 1 2,000 1,245 945002 C 0.623 1,221 C 0.611 2020 25,463 GARDENIA AVE to VIRGINIA AVEUS 1 2,000 1,245 945002 C 0.623 1,221 C 0.611 2020 25,463 SAVANNAH RD to GARDENIA AVEUS 1 2,000 1,245 945002 C 0.623 1,221 C 0.611 2020 23,315 VIRGINIA AVE to OHIO AVEUS 1 2,000 1,147 945003 C 0.574 1,156 C 0.578 2020 23,315 OHIO AVE to GEORGIA AVEUS 1 1,630 1,147 945003 D 0.704 1,156 D 0.709 2020 26,000 GEORGIA AVE to DELAWARE AVEUS 1 1,630 1,341 945008 D 0.823 1,281 D 0.786 2020 27,767 DELAWARE AVE to CITRUS AVEUS 1 1,630 1,437 945014 D 0.882 1,400 D 0.859 2020 22,183 CITRUS AVE to ORANGE AVEUS 1 1,630 1,220 940118 D 0.748 1,100 D 0.675 2020 27,767 ORANGE AVE to AVENUE AUS 1 1,630 1,437 945014 D 0.882 1,400 D 0.859 2020 27,767 AVENUE A to AE BACKUS AVEUS 1 1,630 1,437 945014 D 0.882 1,400 D 0.859 2020 27,767 AE BACKUS AVE to AVENUE DUS 1 1,630 1,437 945014 D 0.882 1,400 D 0.859 2020 27,767 AVENUE D to SR A1A SOUTHUS 1 1,630 1,437 945014 D 0.882 1,400 D 0.859 2020 18 * Volumes shown were adjusted using FDOT Seasonal Factors * AADT = Annual Average Daily Traffic (volumes for both directions where applicable) * Counts with an ID format of 6 digits have data extracted from FDOT count stations. * NOTE: A six digit number in the "STATION ID" column identifies segment counted by FDOT * NOTE: If the Last Count Year is older than the year of the report, the AADT is projected from historical traffic count data. Page 244 of 428 Roadway Name Location AADT Volume LOS V/C PM Pk Hr Pk Dir Pk Hr Service Capacity AM Pk Hr Pk Dir V/C LOS Volume STATION ID Last Count Year Traffic Counts and Level of Service Report 2021 8,424 RUSSOS RD to INDIAN RIVER C.L.JOHNSTON RD 1,070 477 135 C 0.446 479 C 0.448 2020 2,176 53RD ST to 25TH STJUANITA AVE 750 140 122 C 0.187 128 C 0.171 2017 3,226 25TH ST to US 1JUANITA AVE 750 180 120 C 0.24 177 C 0.236 2017 2,926 ANGLE RD to JUANITA AVEKEEN RD 630 176 129 C 0.279 206 C 0.327 2019 2,926 JUANITA AVE to ST LUCIE BLVDKEEN RD 630 176 129 C 0.279 206 C 0.327 2019 7,900 OKEECHOBEE RD to CROSSROADS PKWYKINGS HWY 880 363 940757 C 0.413 371 C 0.422 2020 7,900 CROSSROADS PKWY to GRAHAM RDKINGS HWY 700 363 940757 C 0.519 371 C 0.53 2020 7,000 GRAHAM RD to PICOS RDKINGS HWY 700 337 940076 C 0.481 324 C 0.463 2020 7,000 PICOS RD to ORANGE AVEKINGS HWY 880 337 940076 C 0.383 324 C 0.368 2020 14,100 ORANGE AVE to ANGLE RDKINGS HWY 920 662 940077 C 0.72 666 C 0.724 2020 10,500 ANGLE RD to ST LUCIE BLVDKINGS HWY 880 531 940751 C 0.603 533 C 0.606 2020 13,200 ST LUCIE BLVD to INDRIO RDKINGS HWY 880 744 940006 C 0.845 699 C 0.794 2020 2,400 EDWARDS RD to 35TH STKIRBY LOOP RD 630 139 677 C 0.221 129 C 0.205 2021 3,482 OLEANDER AVE to US 1KITTERMAN RD 750 229 124 C 0.305 208 C 0.277 2018 2,233 US 1 to LENNARD EXTKITTERMAN RD 750 127 678 C 0.169 129 C 0.172 2017 20,078 US 1 to MARIPOSA AVELENNARD RD 1,710 1,034 325 D 0.605 1,068 D 0.625 2019 20,078 MARIPOSA AVE to MELALEUCA BLVDLENNARD RD 1,710 1,034 325 D 0.605 1,068 D 0.625 2019 20,078 MELALEUCA BLVD to JENNINGS RDLENNARD RD 1,630 1,034 325 D 0.634 1,068 D 0.655 2019 20,078 JENNINGS RD to HILLMOOR DRLENNARD RD 1,710 1,034 325 D 0.605 1,068 D 0.625 2019 20,078 HILLMOOR DR to TIFFANY AVELENNARD RD 1,710 1,034 325 D 0.605 1,068 D 0.625 2019 5,764 TIFFANY AVE to WALTON RDLENNARD RD 1,710 301 323 C 0.176 305 C 0.178 2016 3,600 WALTON RD to S OF SAVANNA CLUB BLVDLENNARD RD 790 249 679 C 0.315 236 C 0.299 2021 10,536 VETERANS MEMORIAL PKWY to MORNINGSIDE BLVDLYNGATE DR 920 659 306 C 0.716 701 C 0.762 2020 10,536 MORNINGSIDE BLVD to US 1LYNGATE DR 920 659 306 C 0.716 701 C 0.762 2020 6,912 LENNARD RD to HALLAHAN STMARIPOSA AVE 880 524 166 C 0.595 741 C 0.842 2019 10 * Volumes shown were adjusted using FDOT Seasonal Factors * AADT = Annual Average Daily Traffic (volumes for both directions where applicable) * Counts with an ID format of 6 digits have data extracted from FDOT count stations. * Note: A six digit number in the "STATION ID" column identifies segment counted by FDOT Page 245 of 428 Roadway Name Location AADT Volume LOS V/C PM Pk Hr Pk Dir Pk Hr Service Capacity AM Pk Hr Pk Dir V/C LOS Volume STATION ID Last Count Year Traffic Counts and Level of Service Report 2021 33,000 MORNINGSIDE BLVD to US 1PORT ST LUCIE BLVD 3,170 2,399 945072 C 0.757 1,496 C 0.472 2020 24,000 BAYSHORE BLVD to AIROSO BLVDPRIMA VISTA BLVD 2,100 1,055 314 C 0.502 1,157 C 0.551 2021 20,000 AIROSO BLVD to FLORESTA DRPRIMA VISTA BLVD 2,100 850 150 C 0.405 843 C 0.401 2021 26,500 FLORESTA DR to NARANJA AVEPRIMA VISTA BLVD 2,100 1,525 148 C 0.726 1,451 C 0.691 2021 26,500 NARANJA AVE to RIO MAR DRPRIMA VISTA BLVD 2,000 1,525 148 C 0.763 1,451 C 0.726 2021 17,500 RIO MAR DR to US 1PRIMA VISTA BLVD 2,100 911 146 C 0.434 824 C 0.392 2021 8,500 US 1 to LENNARD RDPRIMA VISTA BLVD 1,790 459 699 C 0.256 437 C 0.244 2021 1,767 MARTIN C.L. to BECKER RDRANGE LINE RD 1,080 118 145 B 0.109 118 B 0.109 2019 1,767 BECKER RD to 2 MI S OF GLADES CUT-OFF RDRANGE LINE RD 1,080 118 145 B 0.109 118 B 0.109 2019 1,767 2 MI S OF GLADES CUT-OFF RD to GLADES CUT-OF...RANGE LINE RD 1,080 118 145 B 0.109 118 B 0.109 2019 5,856 PRIMA VISTA BLVD to BEACH AVERIO MAR DR 750 362 147 C 0.483 380 D 0.507 2020 5,856 BEACH AVE to US 1RIO MAR DR 790 362 147 C 0.458 380 C 0.481 2020 4,400 APRICOT RD to GATLIN BLVDROSSER BLVD 920 203 948510 C 0.221 203 C 0.221 2020 4,400 PAAR DR to APRICOT RDROSSER BLVD 1,070 203 948510 B 0.19 203 B 0.19 2020 9,200 BECKER RD to PAAR DRSAVONA BLVD 790 819 236 E 1.037 736 D 0.932 2021 9,200 PAAR DR to GATLIN BLVDSAVONA BLVD 750 819 236 F 1.092 736 D 0.981 2021 13,000 GATLIN BLVD to CALIFORNIA BLVDSAVONA BLVD 790 603 702 D 0.763 636 D 0.805 2021 4,030 GATLIN BLVD to GALIANO RDSAVAGE BLVD 920 265 168 C 0.288 214 C 0.233 2018 2,178 US 1 to INDIAN RIVER DRSAVANNAH RD 540 155 514 C 0.287 152 C 0.281 2019 8,600 BAYSHORE BLVD to ST JAMES BLVDSELVITZ RD 750 419 948501 D 0.559 419 D 0.559 2020 8,600 ST JAMES BLVD to MIDWAY RDSELVITZ RD 750 419 948501 D 0.559 419 D 0.559 2020 8,600 MIDWAY RD to GLADES CUT-OFF RDSELVITZ RD 700 504 703 C 0.72 508 C 0.726 2021 13,500 GLADES CUT-OFF RD to EDWARDS RDSELVITZ RD 790 715 704 D 0.905 713 D 0.903 2021 800 MIDWAY RD to OKEECHOBEE RDSHINN RD 580 53 705 C 0.091 50 C 0.086 2017 804 OKEECHOBEE RD to ORANGE AVESHINN RD 1,080 60 149 B 0.056 61 B 0.056 2019 15 * Volumes shown were adjusted using FDOT Seasonal Factors * AADT = Annual Average Daily Traffic (volumes for both directions where applicable) * Counts with an ID format of 6 digits have data extracted from FDOT count stations. * Note: A six digit number in the "STATION ID" column identifies segment counted by FDOT Page 246 of 428 Roadway Name Location AADT Volume LOS V/C PM Pk Hr Pk Dir Pk Hr Service Capacity AM Pk Hr Pk Dir V/C LOS Volume STATION ID Last Count Year Traffic Counts and Level of Service Report 2021 30,000 TIFFANY AVE to WALTON RDUS 1 3,020 1,409 945070 C 0.467 1,495 C 0.495 2020 49,500 WALTON RD to VILLAGE GREEN DRUS 1 3,020 2,623 945150 C 0.869 2,352 C 0.779 2020 51,500 VILLAGE GREEN DR to SPANISH LAKES BLVDUS 1 3,170 2,767 940265 C 0.873 2,590 C 0.817 2020 51,500 SPANISH LAKES BLVD to PRIMA VISTA BLVDUS 1 3,170 2,767 940265 C 0.873 2,590 C 0.817 2020 39,500 PRIMA VISTA BLVD to RIO MAR DRUS 1 3,170 1,827 940264 C 0.576 1,798 C 0.567 2020 34,000 RIO MAR DR to KITTERMAN RDUS 1 3,170 1,719 940266 C 0.542 1,557 C 0.491 2020 34,000 KITTERMAN RD to S OF SAEGER AVEUS 1 3,020 1,719 940266 C 0.569 1,557 C 0.516 2020 34,000 S OF SAEGER AVE to EASY STUS 1 3,170 1,719 940266 C 0.542 1,557 C 0.491 2020 29,500 EASY ST to MIDWAY RDUS 1 3,170 1,423 945156 C 0.449 1,383 C 0.436 2020 41,500 MIDWAY RD to WEATHERBEE RDUS 1 2,100 1,867 940012 C 0.889 1,889 C 0.9 2020 41,500 WEATHERBEE RD to FARMER'S MARKET RDUS 1 2,000 1,867 940012 C 0.934 1,889 C 0.945 2020 41,500 FARMER'S MARKET RD to EDWARDS RDUS 1 2,000 1,867 940012 C 0.934 1,889 C 0.945 2020 29,000 EDWARDS RD to SAVANNAH RDUS 1 2,000 1,344 945002 C 0.672 1,318 C 0.659 2020 29,000 GARDENIA AVE to VIRGINIA AVEUS 1 2,000 1,344 945002 C 0.672 1,318 C 0.659 2020 29,000 SAVANNAH RD to GARDENIA AVEUS 1 2,000 1,344 945002 C 0.672 1,318 C 0.659 2020 25,000 VIRGINIA AVE to OHIO AVEUS 1 2,000 1,165 945003 C 0.583 1,174 C 0.587 2020 25,000 OHIO AVE to GEORGIA AVEUS 1 1,630 1,165 945003 D 0.715 1,174 D 0.72 2020 35,500 GEORGIA AVE to DELAWARE AVEUS 1 1,630 1,734 945008 F 1.064 1,658 E 1.017 2020 32,500 DELAWARE AVE to CITRUS AVEUS 1 1,630 1,594 945014 D 0.978 1,553 D 0.953 2020 30,000 CITRUS AVE to ORANGE AVEUS 1 1,630 1,563 940118 D 0.959 1,409 D 0.864 2020 32,500 ORANGE AVE to AVENUE AUS 1 1,630 1,594 945014 D 0.978 1,553 D 0.953 2020 32,500 AVENUE A to AE BACKUS AVEUS 1 1,630 1,594 945014 D 0.978 1,553 D 0.953 2020 32,500 AE BACKUS AVE to AVENUE DUS 1 1,630 1,594 945014 D 0.978 1,553 D 0.953 2020 32,500 AVENUE D to SR A1A SOUTHUS 1 1,630 1,594 945014 D 0.978 1,553 D 0.953 2020 31,500 SR A1A SOUTH to AVENUE HUS 1 2,100 1,590 715 C 0.757 1,584 C 0.754 2021 18 * Volumes shown were adjusted using FDOT Seasonal Factors * AADT = Annual Average Daily Traffic (volumes for both directions where applicable) * Counts with an ID format of 6 digits have data extracted from FDOT count stations. * Note: A six digit number in the "STATION ID" column identifies segment counted by FDOT Page 247 of 428 Roadway Name Location AADT Volume LOS V/C PM Pk Hr Pk Dir Pk Hr Service Capacity AM Pk Hr Pk Dir V/C LOS Volume STATION ID Last Count Year Traffic Counts and Level of Service Report Fall/Winter 2019/2020 9,600 RUSSOS RD to INDIAN RIVER C.L.JOHNSTON RD 1,070 544 135 C 0.716 545 C 0.717 2020 2,432 53RD ST to 25TH STJUANITA AVE 750 157 122 C 0.424 143 C 0.386 2017 3,321 25TH ST to US 1JUANITA AVE 750 185 120 C 0.500 182 C 0.492 2017 2,885 ANGLE RD to JUANITA AVEKEEN RD 630 174 129 C 0.290 203 C 0.338 2019 2,885 JUANITA AVE to ST LUCIE BLVDKEEN RD 630 174 129 C 0.290 203 C 0.338 2019 7,600 OKEECHOBEE RD to CROSSROADS PKWYKINGS HWY 830 333 940757 C 0.401 341 C 0.411 2019 7,600 CROSSROADS PKWY to GRAHAM RDKINGS HWY 660 333 940757 C 0.505 341 C 0.517 2019 7,000 GRAHAM RD to PICOS RDKINGS HWY 660 345 940076 C 0.523 331 C 0.502 2019 7,000 PICOS RD to ORANGE AVEKINGS HWY 830 345 940076 C 0.416 331 C 0.399 2019 13,900 ORANGE AVE to ANGLE RDKINGS HWY 870 732 940077 C 0.841 737 C 0.847 2019 13,100 ANGLE RD to ST LUCIE BLVDKINGS HWY 830 721 940751 C 0.869 725 C 0.873 2019 14,900 ST LUCIE BLVD to INDRIO RDKINGS HWY 830 924 940006 F 1.050 868 D 0.986 2019 3,402 OLEANDER AVE to US 1KITTERMAN RD 750 224 124 C 0.605 203 C 0.549 2018 2,250 US 1 to LENNARD EXTKITTERMAN RD 750 128 678 C 0.346 130 C 0.351 2017 4,479 EDWARDS RD to 35TH STKIRBY LOOP RD 630 296 677 C 0.493 362 C 0.603 2016 18,500 US 1 to MARIPOSA AVELENNARD RD 1,710 953 325 D 0.557 984 D 0.575 2019 18,500 MARIPOSA AVE to MELALEUCA BLVDLENNARD RD 1,710 953 325 D 0.557 984 D 0.575 2019 18,500 MELALEUCA BLVD to JENNINGS RDLENNARD RD 1,630 953 325 D 0.585 984 D 0.604 2019 18,500 JENNINGS RD to HILLMOOR DRLENNARD RD 1,710 953 325 D 0.557 984 D 0.575 2019 18,500 HILLMOOR DR to TIFFANY AVELENNARD RD 1,710 953 325 D 0.557 984 D 0.575 2019 5,765 TIFFANY AVE to WALTON RDLENNARD RD 1,710 301 323 C 0.391 305 C 0.396 2016 4,455 WALTON RD to S OF SAVANNA CLUB BLVDLENNARD RD 790 390 679 C 10 381 C 0.977 2016 9,400 VETERANS MEMORIAL PKWY to MORNINGSIDE BLVDLYNGATE DR 920 588 306 C 0.676 626 C 0.720 2020 9,400 MORNINGSIDE BLVD to US 1LYNGATE DR 920 588 306 C 0.676 626 C 0.720 2020 6,400 LENNARD RD to HALLAHAN STMARIPOSA AVE 880 485 166 C 0.584 686 C 0.827 2019 10 * Volumes shown were adjusted using FDOT Seasonal Factors * AADT = Annual Average Daily Traffic (volumes for both directions where applicable) * Counts with an ID format of 6 digits have data extracted from FDOT count stations. * Note: A six digit number in the "STATION ID" column identifies segment counted by FDOT Page 248 of 428 Roadway Name Location AADT Volume LOS V/C PM Pk Hr Pk Dir Pk Hr Service Capacity AM Pk Hr Pk Dir V/C LOS Volume STATION ID Last Count Year Traffic Counts and Level of Service Report Fall/Winter 2019/2020 44,500 MORNINGSIDE BLVD to US 1PORT ST LUCIE BLVD 3,170 3,379 945072 F 1.066 2,108 C 0.682 2019 21,500 BAYSHORE BLVD to AIROSO BLVDPRIMA VISTA BLVD 2,100 944 314 C 0.470 1,005 C 0.500 2020 25,425 AIROSO BLVD to FLORESTA DRPRIMA VISTA BLVD 2,100 1,171 150 C 0.583 1,097 C 0.546 2018 26,500 FLORESTA DR to NARANJA AVEPRIMA VISTA BLVD 2,100 1,514 148 C 0.753 1,408 C 0.700 2019 26,500 NARANJA AVE to RIO MAR DRPRIMA VISTA BLVD 2,000 1,514 148 C 0.793 1,408 C 0.737 2019 26,283 RIO MAR DR to US 1PRIMA VISTA BLVD 2,100 1,278 146 C 0.636 1,165 C 0.580 2018 7,400 US 1 to LENNARD RDPRIMA VISTA BLVD 1,710 449 699 C 0.583 452 C 0.587 2017 1,780 MARTIN C.L. to BECKER RDRANGE LINE RD 1,080 119 145 B 0.290 119 B 0.290 2019 1,780 BECKER RD to 2 MI S OF GLADES CUT-OFF RDRANGE LINE RD 1,080 119 145 B 0.290 119 B 0.290 2019 1,780 2 MI S OF GLADES CUT-OFF RD to GLADES CUT-OF...RANGE LINE RD 1,080 119 145 B 0.290 119 B 0.290 2019 6,600 PRIMA VISTA BLVD to BEACH AVERIO MAR DR 750 408 147 D 0.544 429 D 0.572 2020 6,600 BEACH AVE to US 1RIO MAR DR 790 408 147 D 0.516 429 D 0.543 2020 4,600 APRICOT RD to GATLIN BLVDROSSER BLVD 920 212 948510 C 0.255 212 C 0.255 2019 4,600 PAAR DR to APRICOT RDROSSER BLVD 1,070 212 948510 B 0.505 212 B 0.505 2019 9,800 BECKER RD to PAAR DRSAVONA BLVD 790 893 236 F 1.063 796 E 0.948 2019 9,800 PAAR DR to GATLIN BLVDSAVONA BLVD 750 893 236 F 1.116 796 E 0.995 2019 14,500 GATLIN BLVD to CALIFORNIA BLVDSAVONA BLVD 790 787 702 D 0.996 732 D 0.927 2019 3,922 GATLIN BLVD to GALIANO RDSAVAGE BLVD 920 258 168 C 0.297 208 C 0.239 2018 2,188 US 1 to INDIAN RIVER DRSAVANNAH RD 540 155 514 C 0.574 153 C 0.567 2019 9,000 BAYSHORE BLVD to ST JAMES BLVDSELVITZ RD 750 438 948501 D 0.584 438 D 0.584 2019 9,000 ST JAMES BLVD to MIDWAY RDSELVITZ RD 750 438 948501 D 0.584 438 D 0.584 2019 10,400 MIDWAY RD to GLADES CUT-OFF RDSELVITZ RD 700 696 703 D 0.994 644 C 0.976 2019 14,000 GLADES CUT-OFF RD to EDWARDS RDSELVITZ RD 790 787 704 D 0.996 752 D 0.952 2020 775 MIDWAY RD to OKEECHOBEE RDSHINN RD 580 51 705 C 0.100 49 C 0.096 2017 819 OKEECHOBEE RD to ORANGE AVESHINN RD 1,080 62 149 B 0.151 62 B 0.151 2019 15 * Volumes shown were adjusted using FDOT Seasonal Factors * AADT = Annual Average Daily Traffic (volumes for both directions where applicable) * Counts with an ID format of 6 digits have data extracted from FDOT count stations. * Note: A six digit number in the "STATION ID" column identifies segment counted by FDOT Page 249 of 428 Roadway Name Location AADT Volume LOS V/C PM Pk Hr Pk Dir Pk Hr Service Capacity AM Pk Hr Pk Dir V/C LOS Volume STATION ID Last Count Year Traffic Counts and Level of Service Report Fall/Winter 2019/2020 31,000 TIFFANY AVE to WALTON RDUS 1 3,020 1,488 945070 C 0.506 1,580 C 0.537 2019 46,500 WALTON RD to VILLAGE GREEN DRUS 1 3,020 2,519 945150 C 0.857 2,258 C 0.768 2019 52,500 VILLAGE GREEN DR to SPANISH LAKES BLVDUS 1 3,170 2,789 940265 C 0.903 2,611 C 0.845 2019 52,500 SPANISH LAKES BLVD to PRIMA VISTA BLVDUS 1 3,170 2,789 940265 C 0.903 2,611 C 0.845 2019 36,000 PRIMA VISTA BLVD to RIO MAR DRUS 1 3,170 1,665 940264 C 0.539 1,639 C 0.530 2019 35,000 RIO MAR DR to KITTERMAN RDUS 1 3,170 1,711 940266 C 0.554 1,549 C 0.501 2019 35,000 KITTERMAN RD to S OF SAEGER AVEUS 1 3,020 1,711 940266 C 0.582 1,549 C 0.527 2019 35,000 S OF SAEGER AVE to EASY STUS 1 3,170 1,711 940266 C 0.554 1,549 C 0.501 2019 31,000 EASY ST to MIDWAY RDUS 1 3,170 1,445 945156 C 0.468 1,405 C 0.455 2019 33,000 MIDWAY RD to WEATHERBEE RDUS 1 2,100 1,551 940012 C 0.772 1,569 C 0.781 2019 33,000 WEATHERBEE RD to FARMER'S MARKET RDUS 1 2,000 1,551 940012 C 0.812 1,569 C 0.821 2019 33,000 FARMER'S MARKET RD to EDWARDS RDUS 1 2,000 1,551 940012 C 0.812 1,569 C 0.821 2019 30,000 EDWARDS RD to SAVANNAH RDUS 1 2,000 1,375 945002 C 0.720 1,348 C 0.706 2019 30,000 GARDENIA AVE to VIRGINIA AVEUS 1 2,000 1,375 945002 C 0.720 1,348 C 0.706 2019 30,000 SAVANNAH RD to GARDENIA AVEUS 1 2,000 1,375 945002 C 0.720 1,348 C 0.706 2019 28,500 VIRGINIA AVE to OHIO AVEUS 1 2,000 1,372 945003 C 0.718 1,383 C 0.724 2019 28,500 OHIO AVE to GEORGIA AVEUS 1 1,630 1,372 945003 D 0.842 1,383 D 0.848 2019 36,500 GEORGIA AVE to DELAWARE AVEUS 1 1,630 1,882 945008 F 1.107 1,799 F 1.058 2019 33,500 DELAWARE AVE to CITRUS AVEUS 1 1,630 1,697 945014 E 0.998 1,654 E 0.973 2019 25,000 CITRUS AVE to ORANGE AVEUS 1 1,630 1,244 940118 D 0.763 1,122 D 0.688 2019 33,500 ORANGE AVE to AVENUE AUS 1 1,630 1,697 945014 E 0.998 1,654 E 0.973 2019 33,500 AVENUE A to AE BACKUS AVEUS 1 1,630 1,697 945014 E 0.998 1,654 E 0.973 2019 33,500 AE BACKUS AVE to AVENUE DUS 1 1,630 1,697 945014 E 0.998 1,654 E 0.973 2019 33,500 AVENUE D to SR A1A SOUTHUS 1 1,630 1,697 945014 E 0.998 1,654 E 0.973 2019 33,500 SR A1A SOUTH to AVENUE HUS 1 2,100 1,766 715 C 0.879 1,742 C 0.867 2020 18 * Volumes shown were adjusted using FDOT Seasonal Factors * AADT = Annual Average Daily Traffic (volumes for both directions where applicable) * Counts with an ID format of 6 digits have data extracted from FDOT count stations. * Note: A six digit number in the "STATION ID" column identifies segment counted by FDOT Page 250 of 428 File Name : US1NBEBAM Site Code : PT2306 Start Date : 10/26/2023 Page No : 1 Manual traffic count - All traffic US-1 and Prima Vista Blvd Port St Lucie, FL Groups Printed- All traffic US-1 NB US-1 SB Prisma Vista EB Prisma Vista WB Start Time Right Thru Left UTurn Right Thru Left UTurn Right Thru Left UTurn Right Thru Left Exclu. Total Inclu. Total Int. Total 07:00 AM 12 222 50 1 40 252 6 6 111 17 51 0 4 20 33 7 818 825 07:15 AM 16 286 60 1 45 264 11 1 138 18 70 0 5 15 25 2 953 955 07:30 AM 24 315 63 2 46 344 8 5 144 23 93 0 6 37 34 7 1137 1144 07:45 AM 26 326 79 1 33 329 10 6 164 32 91 1 9 36 32 8 1167 1175 Total 78 1149 252 5 164 1189 35 18 557 90 305 1 24 108 124 24 4075 4099 08:00 AM 28 256 61 2 40 294 16 4 116 25 90 3 0 0 0 9 926 935 08:15 AM 35 263 77 2 37 328 22 6 133 28 71 3 5 56 54 11 1109 1120 08:30 AM 36 268 65 0 43 341 16 6 134 43 103 1 8 47 62 7 1166 1173 08:45 AM 32 246 59 4 41 295 23 10 138 29 78 1 10 39 50 15 1040 1055 Total 131 1033 262 8 161 1258 77 26 521 125 342 8 23 142 166 42 4241 4283 *** BREAK *** 04:00 PM 26 321 104 0 58 307 21 10 85 41 117 15 11 44 46 25 1181 1206 04:15 PM 36 342 149 0 81 344 33 10 124 43 154 0 13 41 64 10 1424 1434 04:30 PM 49 367 171 2 74 413 26 9 96 31 158 1 16 43 69 12 1513 1525 04:45 PM 45 387 139 2 65 356 29 4 91 39 90 0 12 59 57 6 1369 1375 Total 156 1417 563 4 278 1420 109 33 396 154 519 16 52 187 236 53 5487 5540 05:00 PM 44 430 196 0 84 369 28 7 100 44 139 4 14 68 62 11 1578 1589 05:15 PM 47 396 183 0 105 371 52 15 107 42 104 0 9 64 68 15 1548 1563 05:30 PM 58 322 119 0 61 332 36 10 95 46 95 1 8 54 48 11 1274 1285 05:45 PM 48 312 112 0 53 301 25 12 86 39 89 0 5 48 38 12 1156 1168 Total 197 1460 610 0 303 1373 141 44 388 171 427 5 36 234 216 49 5556 5605 Grand Total 562 5059 1687 17 906 5240 362 121 1862 540 1593 30 135 671 742 168 19359 19527 Apprch %7.7 69.2 23.1 13.9 80.5 5.6 46.6 13.5 39.9 8.7 43.3 47.9 Total %2.9 26.1 8.7 4.7 27.1 1.9 9.6 2.8 8.2 0.7 3.5 3.8 0.9 99.1 KMF Traffic Group, LLC (772) 924-6993 www.kmftraffic.net Page 251 of 428 File Name : US1NBEBAM Site Code : PT2306 Start Date : 10/26/2023 Page No : 2 Manual traffic count - All traffic US-1 and Prima Vista Blvd Port St Lucie, FL US-1 NB US-1 SB Prisma Vista EB Prisma Vista WB Start Time Right Thru Left App. Total Right Thru Left App. Total Right Thru Left App. Total Right Thru Left App. Total Int. Total Peak Hour Analysis From 07:00 AM to 08:45 AM - Peak 1 of 1 Peak Hour for Entire Intersection Begins at 07:45 AM 07:45 AM 26 326 79 431 33 329 10 372 164 32 91 287 9 36 32 77 1167 08:00 AM 28 256 61 345 40 294 16 350 116 25 90 231 0 0 0 0 926 08:15 AM 35 263 77 375 37 328 22 387 133 28 71 232 5 56 54 115 1109 08:30 AM 36 268 65 369 43 341 16 400 134 43 103 280 8 47 62 117 1166 Total Volume 125 1113 282 1520 153 1292 64 1509 547 128 355 1030 22 139 148 309 4368 % App. Total 8.2 73.2 18.6 10.1 85.6 4.2 53.1 12.4 34.5 7.1 45 47.9 PHF .868 .854 .892 .882 .890 .947 .727 .943 .834 .744 .862 .897 .611 .621 .597 .660 .936 US-1 P r i s m a V i s t a P r i s m a V i s t a US-1 Right 153 Thru 1292 Left 64 InOut Total 1490 1509 2999 Rig h t 22 Th r u 13 9 Le f t 14 8 Ou t To t a l In 31 7 30 9 62 6 Left 282 Thru 1113 Right 125 Out TotalIn 1987 1520 3507 Le f t 35 5 Th r u 12 8 Ri g h t 54 7 To t a l Ou t In 57 4 10 3 0 16 0 4 Peak Hour Begins at 07:45 AM All traffic Peak Hour Data North KMF Traffic Group, LLC (772) 924-6993 www.kmftraffic.net Page 252 of 428 File Name : US1NBEBAM Site Code : PT2306 Start Date : 10/26/2023 Page No : 3 Manual traffic count - All traffic US-1 and Prima Vista Blvd Port St Lucie, FL US-1 NB US-1 SB Prisma Vista EB Prisma Vista WB Start Time Right Thru Left App. Total Right Thru Left App. Total Right Thru Left App. Total Right Thru Left App. Total Int. Total Peak Hour Analysis From 04:00 PM to 05:45 PM - Peak 1 of 1 Peak Hour for Entire Intersection Begins at 04:30 PM 04:30 PM 49 367 171 587 74 413 26 513 96 31 158 285 16 43 69 128 1513 04:45 PM 45 387 139 571 65 356 29 450 91 39 90 220 12 59 57 128 1369 05:00 PM 44 430 196 670 84 369 28 481 100 44 139 283 14 68 62 144 1578 05:15 PM 47 396 183 626 105 371 52 528 107 42 104 253 9 64 68 141 1548 Total Volume 185 1580 689 2454 328 1509 135 1972 394 156 491 1041 51 234 256 541 6008 % App. Total 7.5 64.4 28.1 16.6 76.5 6.8 37.8 15 47.2 9.4 43.3 47.3 PHF .944 .919 .879 .916 .781 .913 .649 .934 .921 .886 .777 .913 .797 .860 .928 .939 .952 US-1 P r i s m a V i s t a P r i s m a V i s t a US-1 Right 328 Thru 1509 Left 135 InOut Total 2122 1972 4094 Ri g h t 51 Th r u 23 4 Le f t 25 6 Ou t To t a l In 47 6 54 1 10 1 7 Left 689 Thru 1580 Right 185 Out TotalIn 2159 2454 4613 Le f t 49 1 Th r u 15 6 Ri g h t 39 4 To t a l Ou t In 12 5 1 10 4 1 22 9 2 Peak Hour Begins at 04:30 PM All traffic Peak Hour Data North KMF Traffic Group, LLC (772) 924-6993 www.kmftraffic.net Page 253 of 428 File Name : PVITIL Site Code : PT2306 Start Date : 10/26/2023 Page No : 1 Manual movemts count - All traffic Prima Vista and Tilton/Lennard Rd Port St Lucie, FL Groups Printed- All traffic Tilton Rd NB Tilton Rd SB Prima Vista EB Start Time Thru Left Right Thru Right Left Int. Total 07:00 AM 4 7 8 0 6 9 34 07:15 AM 6 8 14 0 0 17 45 07:30 AM 4 15 11 5 2 17 54 07:45 AM 1 9 13 7 6 23 59 Total 15 39 46 12 14 66 192 08:00 AM 6 5 16 0 0 27 54 08:15 AM 3 8 68 4 3 46 132 08:30 AM 4 8 48 3 5 46 114 08:45 AM 1 12 17 0 2 9 41 Total 14 33 149 7 10 128 341 *** PM *** 04:00 PM 4 5 14 6 4 8 41 04:15 PM 1 8 12 7 9 14 51 04:30 PM 6 11 11 1 9 12 50 04:45 PM 3 8 14 3 6 12 46 Total 14 32 51 17 28 46 188 05:00 PM 1 5 12 1 8 8 35 05:15 PM 3 8 27 7 9 13 67 05:30 PM 1 12 19 6 8 12 58 05:45 PM 4 1 12 4 13 23 57 Total 9 26 70 18 38 56 217 Grand Total 52 130 316 54 90 296 938 Apprch %28.6 71.4 85.4 14.6 23.3 76.7 Total %5.5 13.9 33.7 5.8 9.6 31.6 KMF Traffic Group, LLC (772) 924-6993 www.kmftraffic.net Page 254 of 428 File Name : PVITIL Site Code : PT2306 Start Date : 10/26/2023 Page No : 2 Manual movemts count - All traffic Prima Vista and Tilton/Lennard Rd Port St Lucie, FL Tilton Rd NB Tilton Rd SB Prima Vista EB Start Time Thru Left App. Total Right Thru App. Total Right Left App. Total Int. Total Peak Hour Analysis From 07:00 AM to 08:45 AM - Peak 1 of 1 Peak Hour for Entire Intersection Begins at 07:45 AM 07:45 AM 1 9 10 13 7 20 6 23 29 59 08:00 AM 6 5 11 16 0 16 0 27 27 54 08:15 AM 3 8 11 68 4 72 3 46 49 132 08:30 AM 4 8 12 48 3 51 5 46 51 114 Total Volume 14 30 44 145 14 159 14 142 156 359 % App. Total 31.8 68.2 91.2 8.8 9 91 PHF .583 .833 .917 .533 .500 .552 .583 .772 .765 .680 Tilton Rd P r i m a V i s t a Tilton Rd Right 145 Thru 14 InOut Total 156 159 315 Left 30 Thru 14 Out TotalIn 28 44 72 Le f t 14 2 Ri g h t 14 To t a l Ou t In 17 5 15 6 33 1 Peak Hour Begins at 07:45 AM All traffic Peak Hour Data North KMF Traffic Group, LLC (772) 924-6993 www.kmftraffic.net Page 255 of 428 File Name : PVITIL Site Code : PT2306 Start Date : 10/26/2023 Page No : 3 Manual movemts count - All traffic Prima Vista and Tilton/Lennard Rd Port St Lucie, FL Tilton Rd NB Tilton Rd SB Prima Vista EB Start Time Thru Left App. Total Right Thru App. Total Right Left App. Total Int. Total Peak Hour Analysis From 04:00 PM to 05:45 PM - Peak 1 of 1 Peak Hour for Entire Intersection Begins at 05:00 PM 05:00 PM 1 5 6 12 1 13 8 8 16 35 05:15 PM 3 8 11 27 7 34 9 13 22 67 05:30 PM 1 12 13 19 6 25 8 12 20 58 05:45 PM 4 1 5 12 4 16 13 23 36 57 Total Volume 9 26 35 70 18 88 38 56 94 217 % App. Total 25.7 74.3 79.5 20.5 40.4 59.6 PHF .563 .542 .673 .648 .643 .647 .731 .609 .653 .810 Tilton Rd P r i m a V i s t a Tilton Rd Right 70 Thru 18 InOut Total 65 88 153 Left 26 Thru 9 Out TotalIn 56 35 91 Le f t 56 Ri g h t 38 To t a l Ou t In 96 94 19 0 Peak Hour Begins at 05:00 PM All traffic Peak Hour Data North KMF Traffic Group, LLC (772) 924-6993 www.kmftraffic.net Page 256 of 428 File Name : TISO Site Code : PT2306 Start Date : 10/26/2023 Page No : 1 Manual traffic count - All traffic Tilton Rd and Silver Oak Dr Port St Lucie, FL Groups Printed- All traffic Silver Oak Dr NB Silver Oak Dr SB Tilton RD EB Tilton RD WB Start Time Right Thru Left Right Thru Left Right Thru Left Right Thru Left Int. Total 07:00 AM 1 0 3 1 0 0 0 2 1 0 3 0 11 07:15 AM 0 0 4 2 0 0 0 1 1 0 9 0 17 07:30 AM 1 1 4 1 0 0 2 2 1 0 13 0 25 07:45 AM 0 0 2 3 0 0 4 3 4 0 6 0 22 Total 2 1 13 7 0 0 6 8 7 0 31 0 75 08:00 AM 0 0 4 4 0 0 0 2 3 0 3 0 16 08:15 AM 0 0 0 2 0 0 1 2 0 0 5 0 10 08:30 AM 1 1 2 0 0 0 3 3 1 0 6 2 19 08:45 AM 0 0 4 2 0 0 1 3 0 0 4 0 14 Total 1 1 10 8 0 0 5 10 4 0 18 2 59 *** PMK *** 04:00 PM 2 0 3 2 0 0 2 5 0 0 4 0 18 04:15 PM 1 1 1 0 0 0 5 5 2 0 3 0 18 04:30 PM 3 1 1 6 0 0 2 3 3 0 7 0 26 04:45 PM 1 0 1 3 1 0 1 5 3 0 5 0 20 Total 7 2 6 11 1 0 10 18 8 0 19 0 82 05:00 PM 2 1 3 1 0 0 0 6 0 0 2 0 15 05:15 PM 5 0 4 1 0 0 0 9 3 0 2 2 26 05:30 PM 7 0 2 3 0 0 3 10 2 0 6 0 33 05:45 PM 0 1 1 0 0 1 2 8 1 0 3 0 17 Total 14 2 10 5 0 1 5 33 6 0 13 2 91 Grand Total 24 6 39 31 1 1 26 69 25 0 81 4 307 Apprch %34.8 8.7 56.5 93.9 3 3 21.7 57.5 20.8 0 95.3 4.7 Total %7.8 2 12.7 10.1 0.3 0.3 8.5 22.5 8.1 0 26.4 1.3 KMF Traffic Group, LLC (772) 924-6993 www.kmftraffic.net Page 257 of 428 File Name : TISO Site Code : PT2306 Start Date : 10/26/2023 Page No : 2 Manual traffic count - All traffic Tilton Rd and Silver Oak Dr Port St Lucie, FL Silver Oak Dr NB Silver Oak Dr SB Tilton RD EB Tilton RD WB Start Time Right Thru Left App. Total Right Thru Left App. Total Right Thru Left App. Total Right Thru Left App. Total Int. Total Peak Hour Analysis From 07:00 AM to 08:45 AM - Peak 1 of 1 Peak Hour for Entire Intersection Begins at 07:15 AM 07:15 AM 0 0 4 4 2 0 0 2 0 1 1 2 0 9 0 9 17 07:30 AM 1 1 4 6 1 0 0 1 2 2 1 5 0 13 0 13 25 07:45 AM 0 0 2 2 3 0 0 3 4 3 4 11 0 6 0 6 22 08:00 AM 0 0 4 4 4 0 0 4 0 2 3 5 0 3 0 3 16 Total Volume 1 1 14 16 10 0 0 10 6 8 9 23 0 31 0 31 80 % App. Total 6.2 6.2 87.5 100 0 0 26.1 34.8 39.1 0 100 0 PHF .250 .250 .875 .667 .625 .000 .000 .625 .375 .667 .563 .523 .000 .596 .000 .596 .800 Silver Oak Dr T i l t o n R D T i l t o n R D Silver Oak Dr Right 10 Thru 0 Left 0 InOut Total 10 10 20 Rig h t 0 Th r u 31 Le f t 0 Ou t To t a l In 9 31 40 Left 14 Thru 1 Right 1 Out TotalIn 6 16 22 Le f t 9 Th r u 8 Ri g h t 6 To t a l Ou t In 55 23 78 Peak Hour Begins at 07:15 AM All traffic Peak Hour Data North KMF Traffic Group, LLC (772) 924-6993 www.kmftraffic.net Page 258 of 428 File Name : TISO Site Code : PT2306 Start Date : 10/26/2023 Page No : 3 Manual traffic count - All traffic Tilton Rd and Silver Oak Dr Port St Lucie, FL Silver Oak Dr NB Silver Oak Dr SB Tilton RD EB Tilton RD WB Start Time Right Thru Left App. Total Right Thru Left App. Total Right Thru Left App. Total Right Thru Left App. Total Int. Total Peak Hour Analysis From 04:00 PM to 05:45 PM - Peak 1 of 1 Peak Hour for Entire Intersection Begins at 04:45 PM 04:45 PM 1 0 1 2 3 1 0 4 1 5 3 9 0 5 0 5 20 05:00 PM 2 1 3 6 1 0 0 1 0 6 0 6 0 2 0 2 15 05:15 PM 5 0 4 9 1 0 0 1 0 9 3 12 0 2 2 4 26 05:30 PM 7 0 2 9 3 0 0 3 3 10 2 15 0 6 0 6 33 Total Volume 15 1 10 26 8 1 0 9 4 30 8 42 0 15 2 17 94 % App. Total 57.7 3.8 38.5 88.9 11.1 0 9.5 71.4 19 0 88.2 11.8 PHF .536 .250 .625 .722 .667 .250 .000 .563 .333 .750 .667 .700 .000 .625 .250 .708 .712 Silver Oak Dr T i l t o n R D T i l t o n R D Silver Oak Dr Right 8 Thru 1 Left 0 InOut Total 9 9 18 Ri g h t 0 Th r u 15 Le f t 2 Ou t To t a l In 45 17 62 Left 10 Thru 1 Right 15 Out TotalIn 7 26 33 Le f t 8 Th r u 30 Ri g h t 4 To t a l Ou t In 33 42 75 Peak Hour Begins at 04:45 PM All traffic Peak Hour Data North KMF Traffic Group, LLC (772) 924-6993 www.kmftraffic.net Page 259 of 428 Intersections 23-081 11-2-23 Historic Growth Rate =2.00% Nominal Growth Rate =1.00% Peak Season =1.17 Buildout Year = 2026 Years =3 Northbound Southbound Eastbound Westbound LT Thru RT LT Thru RT LT Thru RT LT Thru RT Existing Volume (10/26/23)30 14 0 0 14 145 142 0 14 0 0 0 Peak Season Volume 35 16 0 0 16 170 166 0 16 0 0 0 SUM Northbound Southbound Eastbound Westbound LT Thru RT LT Thru RT LT Thru RT LT Thru RT Existing Volume (10/26/23)26 9 0 0 18 70 56 0 38 0 0 0 Peak Season Volume 30 11 0 0 21 82 66 0 44 0 0 0 SUM AM (PM) Northbound:183 (76) Southbound:186 (103) * Prima Vista Commons and Silver Oaks 11/8/2023 17:31 PM Peak Hour Intersection Volume Development Lennard Rd Extension counts Walton Ranch Prima Vista Pkwy & Lennard Rd Ext. (Existing Geometrics w/Project) AM Peak Hour Intersection Volume Development Page 260 of 428 2022 PEAK SEASON FACTOR CATEGORY REPORT - REPORT TYPE: ALL CATEGORY: 9400 EAST-A1A TO US1 MOCF: 0.90 WEEK DATES SF PSCF ================================================================================ 1 01/01/2022 - 01/01/2022 1.02 1.13 2 01/02/2022 - 01/08/2022 1.00 1.11 3 01/09/2022 - 01/15/2022 0.97 1.08 4 01/16/2022 - 01/22/2022 0.95 1.06 * 5 01/23/2022 - 01/29/2022 0.93 1.03 * 6 01/30/2022 - 02/05/2022 0.91 1.01 * 7 02/06/2022 - 02/12/2022 0.89 0.99 * 8 02/13/2022 - 02/19/2022 0.87 0.97 * 9 02/20/2022 - 02/26/2022 0.87 0.97 *10 02/27/2022 - 03/05/2022 0.87 0.97 *11 03/06/2022 - 03/12/2022 0.87 0.97 *12 03/13/2022 - 03/19/2022 0.87 0.97 *13 03/20/2022 - 03/26/2022 0.88 0.98 *14 03/27/2022 - 04/02/2022 0.90 1.00 *15 04/03/2022 - 04/09/2022 0.91 1.01 *16 04/10/2022 - 04/16/2022 0.93 1.03 *17 04/17/2022 - 04/23/2022 0.95 1.06 18 04/24/2022 - 04/30/2022 0.96 1.07 19 05/01/2022 - 05/07/2022 0.98 1.09 20 05/08/2022 - 05/14/2022 1.00 1.11 21 05/15/2022 - 05/21/2022 1.01 1.12 22 05/22/2022 - 05/28/2022 1.03 1.14 23 05/29/2022 - 06/04/2022 1.05 1.17 24 06/05/2022 - 06/11/2022 1.07 1.19 25 06/12/2022 - 06/18/2022 1.08 1.20 26 06/19/2022 - 06/25/2022 1.09 1.21 27 06/26/2022 - 07/02/2022 1.09 1.21 28 07/03/2022 - 07/09/2022 1.09 1.21 29 07/10/2022 - 07/16/2022 1.09 1.21 30 07/17/2022 - 07/23/2022 1.09 1.21 31 07/24/2022 - 07/30/2022 1.09 1.21 32 07/31/2022 - 08/06/2022 1.08 1.20 33 08/07/2022 - 08/13/2022 1.08 1.20 34 08/14/2022 - 08/20/2022 1.08 1.20 35 08/21/2022 - 08/27/2022 1.09 1.21 36 08/28/2022 - 09/03/2022 1.10 1.22 37 09/04/2022 - 09/10/2022 1.11 1.23 38 09/11/2022 - 09/17/2022 1.12 1.24 39 09/18/2022 - 09/24/2022 1.10 1.22 40 09/25/2022 - 10/01/2022 1.09 1.21 41 10/02/2022 - 10/08/2022 1.07 1.19 42 10/09/2022 - 10/15/2022 1.05 1.17 43 10/16/2022 - 10/22/2022 1.05 1.17 44 10/23/2022 - 10/29/2022 1.05 1.17 45 10/30/2022 - 11/05/2022 1.06 1.18 46 11/06/2022 - 11/12/2022 1.06 1.18 47 11/13/2022 - 11/19/2022 1.06 1.18 48 11/20/2022 - 11/26/2022 1.05 1.17 49 11/27/2022 - 12/03/2022 1.04 1.16 50 12/04/2022 - 12/10/2022 1.03 1.14 51 12/11/2022 - 12/17/2022 1.02 1.13 52 12/18/2022 - 12/24/2022 1.00 1.11 53 12/25/2022 - 12/31/2022 0.97 1.08 * PEAK SEASON 23-FEB-2023 09:11:22 830UPD 4_9400_PKSEASON.TXT Page 261 of 428 APPENDIX C Page 262 of 428 Land Use: 210 Single-Family Detached Housing Description A single-family detached housing site includes any single-family detached home on an individual lot. A typical site surveyed is a suburban subdivision. Specialized Land Use Data have been submitted for several single-family detached housing developments with homes that are commonly referred to as patio homes. A patio home is a detached housing unit that is located on a small lot with little (or no) front or back yard. In some subdivisions, communal maintenance of outside grounds is provided for the patio homes. The three patio home sites total 299 dwelling units with overall weighted average trip generation rates of 5.35 vehicle trips per dwelling unit for weekday, 0.26 for the AM adjacent street peak hour, and 0.47 for the PM adjacent street peak hour. These patio home rates based on a small sample of sites are lower than those for single-family detached housing (Land Use 210), lower than those for single-family attached housing (Land Use 251), and higher than those for senior adult housing -- single-family (Land Use 251). Further analysis of this housing type will be conducted in a future edition of Trip Generation Manual. Additional Data The technical appendices provide supporting information on time-of-day distributions for this land use. The appendices can be accessed through either the ITETripGen web app or the trip generation resource page on the ITE website (https://www.ite.org/technical-resources/topics/trip- and-parking-generation/). For 30 of the study sites, data on the number of residents and number of household vehicles are available. The overall averages for the 30 sites are 3.6 residents per dwelling unit and 1.5 vehicles per dwelling unit. The sites were surveyed in the 1980s, the 1990s, the 2000s, and the 2010s in Arizona, California, Connecticut, Delaware, Illinois, Indiana, Kentucky, Maryland, Massachusetts, Minnesota, Montana, New Jersey, North Carolina, Ohio, Ontario (CAN), Oregon, Pennsylvania, South Carolina, South Dakota, Tennessee, Vermont, Virginia, and West Virginia. Source Numbers 100, 105, 114, 126, 157, 167, 177, 197, 207, 211, 217, 267, 275, 293, 300, 319, 320, 356, 357, 367, 384, 387, 407, 435, 522, 550, 552, 579, 598, 601, 603, 614, 637, 711, 716, 720, 728, 735, 868, 869, 903, 925, 936, 1005, 1007, 1008, 1010, 1033, 1066, 1077,1078, 1079 218 Trip Generation Manual 11th Edition • Volume 3 Page 263 of 428 Single-Family Detached Housing(210) Vehicle Trip Ends vs:Dwelling Units On a:Weekday Setting/Location:General Urban/Suburban Number of Studies:174 Avg.Num.of Dwelling Units:246 Directional Distribution:50%entering,50%exiting Vehicle Trip Generation per Dwelling Unit Average Rate Range of Rates Standard Deviation 9.43 4.45 -22.61 2.13 Data Plot and Equation 0 1000 2000 30000 10000 20000 30000 Average RateStudySiteFittedCurve Fitted Curve Equation:Ln(T)=0.92 Ln(X)+2.68 R²=0.95 X =Number of Dwelling Units T = T r i p s E n d s 219General Urban/Suburban and Rural (Land Uses 000–399) Page 264 of 428 Single-Family Detached Housing(210) Vehicle Trip Ends vs:Dwelling Units On a:Weekday, Peak Hour of Adjacent Street Traffic, One Hour Between 7 and 9 a.m. Setting/Location:General Urban/Suburban Number of Studies:192 Avg.Num.of Dwelling Units:226 Directional Distribution:26%entering,74%exiting Vehicle Trip Generation per Dwelling Unit Average Rate Range of Rates Standard Deviation 0.70 0.27 -2.27 0.24 Data Plot and Equation 0 1000 2000 30000 1000 2000 Average RateStudySiteFittedCurve Fitted Curve Equation:Ln(T)=0.91 Ln(X)+0.12 R²=0.90 X =Number of Dwelling Units T = T r i p s E n d s 220 Trip Generation Manual 11th Edition • Volume 3 Page 265 of 428 Single-Family Detached Housing(210) Vehicle Trip Ends vs:Dwelling Units On a:Weekday, Peak Hour of Adjacent Street Traffic, One Hour Between 4 and 6 p.m. Setting/Location:General Urban/Suburban Number of Studies:208 Avg.Num.of Dwelling Units:248 Directional Distribution:63%entering,37%exiting Vehicle Trip Generation per Dwelling Unit Average Rate Range of Rates Standard Deviation 0.94 0.35 -2.98 0.31 Data Plot and Equation 0 1000 2000 30000 1000 2000 3000 Average RateStudySiteFittedCurve Fitted Curve Equation:Ln(T)=0.94 Ln(X)+0.27 R²=0.92 X =Number of Dwelling Units T = T r i p s E n d s 221General Urban/Suburban and Rural (Land Uses 000–399) Page 266 of 428 APPENDIX D Page 267 of 428 TRAFFIC IMPACT ANALYSIS Prima Vista Commons Saint Lucie County, FL Prepared for: AR Building, Inc. Nashville, Tennessee Prepared by: 1172 SW 30th Street, Suite 500 Palm City, FL 34990 (772) 286-8030 225001 March 2022 Revised January 2022 Revised December 2021 Revised September 2021 © MacKenzie Engineering and Planning, Inc. CA 29013 Shaun G. MacKenzie P.E. Florida License # 61751 Page 268 of 428 225001 Page 7 Table 4. Pre-development 2024 PM Peak Hour Roadway Analysis Table 5. Post-development 2024 PM Peak Hour Roadway Analysis All roadways within the study area are expected to operate acceptably as shown in Table 5. Roadway From To Dir Lanes Service Capacity Peak Hour Existing Traffic PSCF Count Year Growth Rate Traffic Growth 2024 Background Traffic Meets Service Volume US 1 Tilton Rd / Lennard Rd EB 4 1700 420 1.19 2021 2.0%31 530 YES US 1 Tilton Rd / Lennard Rd WB 4 1700 468 1.19 2021 2.0%34 591 YES US1 Project site EB/SB 2 750 170 1.19 2021 2.0%12 215 YES US1 Project site WB/NB 2 750 159 1.19 2021 2.0%12 201 YES Project site Prima Vista Dr.SB 2 750 82 1.19 2021 2.0%6 104 YES Project site Prima Vista Dr.NB 2 750 136 1.19 2021 2.0%10 172 YES Tilton Rd/Lennard Rd Prima Vista Blvd Roadway From To Dir Lanes Service Capacity 2024 Background Traffic Assign Project Traffic 2024 Total Traffic Meets Service Volume US 1 Tilton Rd / Lennard Rd EB 4 1,700 530 68%24 554 YES US 1 Tilton Rd / Lennard Rd WB 4 1,700 591 68%16 607 YES US1 Project site EB/SB 2 750 215 32%12 227 YES US1 Project site WB/NB 2 750 201 32%7 208 YES Project site Prima Vista Dr.SB 2 750 104 68%24 128 YES Project site Prima Vista Dr.NB 2 750 172 68%16 188 YES Tilton Rd/Lennard Rd Prima Vista Blvd Page 269 of 428 225001 Page 13 Figure 3. Proposed Driveway Volumes (IN) 30% (11)13 (7)30%(OUT) 4 1 0 2%(OUT) Kitterman 0 (1) 2% (IN) In Out In Out 12 42 36 23 (IN) 32% (12) 4 13 (7)32%(OUT) 29 (16)68%(OUT) DW 1 8 (24) 68% (IN) (IN)(OUT)(OUT) 3%68%1% (1)1 (1)3%(OUT)(16)0 0 8 (5)20%(OUT)29 0 19 (10)45%(OUT)0% Prima Vista (IN)68%(24)8 (IN)20%(7)3 5 (16)0 0 1%(IN)Tilton Rd. 45% (IN) US 1 0%0% Total daily driveway trips PM peak hour driveway trips AM peak hour directional driveway trips 669 (59) 54 Prima Vista Commons PROPOSED PROJECT DRIVEWAY VOLUMES PROJECT DRIVEWAY TRIPS Daily 669 54 Total Total 59 AM Peak Hour PM Peak Hour Page 270 of 428 Page 271 of 428 Page 272 of 428 Page 273 of 428 Page 274 of 428 SILVER OAKS UPDATE EXHIBIT 6 PROJECT DRIVEWAY VOLUMES PTC 02/02/07 06-149 LE N N A R D R D E X T . N.T.S. SITE TILTON ROAD LENNARD ROAD PRIMA VISTA SI L V E R O A K S US 1 REVISED 11/9/23 TO SHOW INTERSECTION VOLUMES 45 (26)13 ( 4 8 ) 53 -AM PEAK HOUR (30) -PM PEAK HOUR 847 -ADT LEGEND 726 847 14 (55) 53 ( 3 0 ) 847 14 (55) 53 ( 3 0 ) 15 1 ( 8 6 ) 41 (158) 13 (48) 45 ( 2 6 ) 28 (110) 106 (60) 45 (26) 12 (48) 12 ( 4 7 ) 17 ( 6 3 ) 61 (34) 45 (26) Page 275 of 428 APPENDIX E Page 276 of 428 Intersections 23-081 3-19-24 Historic Growth Rate =2.00% Nominal Growth Rate =1.00% Peak Season =1.17 Buildout Year = 2026 Years =3 Northbound Southbound Eastbound Westbound LT Thru RT LT Thru RT LT Thru RT LT Thru RT Existing Volume (10/26/23)282 1113 125 64 1292 153 355 128 547 148 139 22 Peak Season Volume 330 1302 146 75 1512 179 415 150 640 173 163 26 SUM Historic Growth 20 80 9 5 93 11 25 9 39 11 10 2 314 Nominal Growth 10 39 4 2 46 5 13 5 19 5 5 1 Approved Projects*0 0 22 12 0 0 0 15 0 80 53 46 Highest Inters. Growth 10 39 26 14 46 5 13 20 19 85 58 47 Background Traffic 340 1,341 172 89 1,558 184 428 170 659 258 221 73 % Project Traffic 0% 0% 40% 8% 0% 0% 0% 20% 0% 40% 20% 8% Direction in in in in in in in in in out out out Project Traffic 0 0 11 2 0 0 0 5 0 30 15 6 Total 340 1,341 183 91 1,558 184 428 175 659 288 236 79 Northbound Southbound Eastbound Westbound LT Thru RT LT Thru RT LT Thru RT LT Thru RT Existing Volume (10/26/23)689 1580 185 135 1509 328 491 156 394 256 234 51 Peak Season Volume 806 1849 216 158 1766 384 574 183 461 300 274 60 SUM Historic Growth 49 113 13 10 108 23 35 11 28 18 17 4 429 Nominal Growth 24 56 7 5 53 12 17 6 14 9 8 2 Approved Projects*0 0 79 48 0 0 0 55 0 44 31 27 Highest Inters. Growth 24 56 86 53 53 12 17 61 14 53 39 29 Background Traffic 830 1,905 302 211 1,819 396 591 244 475 353 313 89 % Project Traffic 0% 0% 40% 8% 0% 0% 0% 20% 0% 40% 20% 8% Direction in in in in in in in in in out out out Project Traffic 0 0 34 7 0 0 0 17 0 20 10 4 Total 830 1,905 337 218 1,819 396 591 261 475 373 323 93 * Prima Vista Commons and Silver Oaks 3/19/2024 13:34 INTERSECTION ANALYSIS SHEET Walton Ranch Prima Vista Pkwy & US 1 (Existing Geometrics w/Project) AM Peak Hour Intersection Volume Development 382 PM Peak Hour Intersection Volume Development 497 Page 277 of 428 HCS Signalized Intersection Results Summary General Information Intersection Information Agency PTC Duration, h 0.250 Analyst #23-081 Analysis Date Mar 20, 2024 Area Type Other Jurisdiction SLC Time Period AM Peak PHF 0.95 Urban Street US 1 Analysis Year 2023 Analysis Period 1> 7:00 Intersection Prima Vista Blvd & US 1 File Name PV US 1 AM exist.xus Project Description Walton Ranch; Existing Demand Information EB WB NB SB Approach Movement L T R L T R L T R L T R Demand ( v ), veh/h 415 150 640 173 163 26 330 1302 146 75 1512 179 Signal Information Green Yellow Red 9.6 4.0 62.7 19.6 5.2 34.8 4.8 4.8 4.8 4.0 0.0 4.0 2.0 2.0 2.0 3.0 0.0 3.0 1 2 3 4 5 6 7 8 Cycle, s 170.2 Reference Phase 2 Offset, s 0 Reference Point End Uncoordinated Yes Simult. Gap E/W On Force Mode Fixed Simult. Gap N/S On Timer Results EBL EBT WBL WBT NBL NBT SBL SBT Assigned Phase 3 8 7 4 1 6 5 2 Case Number 2.0 3.0 2.0 3.0 2.0 3.0 2.0 3.0 Phase Duration, s 31.7 47.0 26.6 41.8 27.2 80.3 16.4 69.5 Change Period, ( Y+R c ), s 7.0 7.0 7.0 7.0 6.8 6.8 6.8 6.8 Max Allow Headway ( MAH ), s 4.1 4.2 4.1 4.2 4.0 4.0 4.0 4.0 Queue Clearance Time ( g s ), s 23.0 42.0 19.2 8.9 19.1 33.5 9.6 50.4 Green Extension Time ( g e ), s 1.7 0.0 0.4 3.7 1.3 23.8 0.2 12.3 Phase Call Probability 1.00 1.00 1.00 1.00 1.00 1.00 0.98 1.00 Max Out Probability 0.00 1.00 0.01 0.09 0.00 0.50 0.00 0.72 Movement Group Results EB WB NB SB Approach Movement L T R L T R L T R L T R Assigned Movement 3 8 18 7 4 14 1 6 16 5 2 12 Adjusted Flow Rate ( v ), veh/h 437 311 458 182 172 27 347 1371 154 79 1592 188 Adjusted Saturation Flow Rate ( s ), veh/h/ln 1730 1730 1585 1781 1781 1585 1689 1658 1547 1739 1658 1547 Queue Service Time ( g s ), s 21.0 28.5 40.0 17.2 6.9 2.4 17.1 31.5 8.3 7.6 48.4 9.7 Cycle Queue Clearance Time ( g c ), s 21.0 28.5 40.0 17.2 6.9 2.4 17.1 31.5 8.3 7.6 48.4 9.7 Green Ratio ( g/C )0.15 0.24 0.35 0.11 0.20 0.20 0.12 0.43 0.43 0.06 0.37 0.51 Capacity ( c ), veh/h 503 407 562 205 729 324 404 2147 668 98 1831 794 Volume-to-Capacity Ratio ( X )0.869 0.764 0.814 0.889 0.235 0.084 0.859 0.638 0.230 0.808 0.869 0.237 Back of Queue ( Q ), ft/ln (95 th percentile)377.4 494.7 665.3 349.2 142.8 44.3 306.5 433.5 136.8 173.8 666 154.8 Back of Queue ( Q ), veh/ln ( 95 th percentile)14.9 19.5 26.2 13.7 5.6 1.7 11.8 16.7 5.3 6.7 25.6 6.0 Queue Storage Ratio ( RQ ) ( 95 th percentile)1.57 0.00 1.39 1.25 0.00 0.30 0.61 0.00 0.65 0.64 0.00 0.43 Uniform Delay ( d 1 ), s/veh 71.2 60.7 49.8 74.2 56.6 54.8 70.1 27.2 22.3 77.8 39.7 18.1 Incremental Delay ( d 2 ), s/veh 5.9 8.4 9.0 17.7 0.2 0.1 5.4 0.6 0.2 14.4 4.0 0.2 Initial Queue Delay ( d 3 ), s/veh 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Control Delay ( d ), s/veh 77.1 69.0 58.8 92.0 56.7 54.9 75.5 27.8 22.5 92.2 43.7 18.3 Level of Service (LOS)E E E F E D E C C F D B Approach Delay, s/veh / LOS 68.1 E 73.4 E 36.3 D 43.2 D Intersection Delay, s/veh / LOS 48.6 D Multimodal Results EB WB NB SB Pedestrian LOS Score / LOS 2.86 C 2.74 C 2.29 B 2.54 C Bicycle LOS Score / LOS 2.48 B 0.80 A 1.52 B 1.51 B Copyright © 2024 University of Florida, All Rights Reserved.HCS™ Streets Version 2023 Generated: 3/20/2024 1:29:46 PM Page 278 of 428 HCS Signalized Intersection Results Summary General Information Intersection Information Agency PTC Duration, h 0.250 Analyst #23-081 Analysis Date Mar 20, 2024 Area Type Other Jurisdiction SLC Time Period PM Peak PHF 0.95 Urban Street US 1 Analysis Year 2023 Analysis Period 1> 7:00 Intersection Prima Vista Blvd & US 1 File Name PV US 1 PM exist.xus Project Description Walton Ranch; Existing Demand Information EB WB NB SB Approach Movement L T R L T R L T R L T R Demand ( v ), veh/h 574 183 461 300 274 60 806 1849 216 158 1766 384 Signal Information Green Yellow Red 21.6 11.6 70.0 30.0 1.0 29.0 4.8 4.8 4.8 4.0 4.0 4.0 2.0 2.0 2.0 3.0 3.0 3.0 1 2 3 4 5 6 7 8 Cycle, s 204.6 Reference Phase 2 Offset, s 0 Reference Point End Uncoordinated Yes Simult. Gap E/W On Force Mode Fixed Simult. Gap N/S On Timer Results EBL EBT WBL WBT NBL NBT SBL SBT Assigned Phase 3 8 7 4 1 6 5 2 Case Number 2.0 3.0 2.0 3.0 2.0 3.0 2.0 3.0 Phase Duration, s 45.0 44.0 37.0 36.0 46.8 95.2 28.4 76.8 Change Period, ( Y+R c ), s 7.0 7.0 7.0 7.0 6.8 6.8 6.8 6.8 Max Allow Headway ( MAH ), s 4.1 4.2 4.1 4.2 4.2 4.2 4.2 4.2 Queue Clearance Time ( g s ), s 37.3 36.0 32.0 17.5 42.0 73.0 21.3 72.0 Green Extension Time ( g e ), s 0.8 1.0 0.0 2.4 0.0 0.0 0.3 0.0 Phase Call Probability 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Max Out Probability 1.00 1.00 1.00 0.47 1.00 1.00 0.03 1.00 Movement Group Results EB WB NB SB Approach Movement L T R L T R L T R L T R Assigned Movement 3 8 18 7 4 14 1 6 16 5 2 12 Adjusted Flow Rate ( v ), veh/h 604 298 317 316 288 11 848 1946 164 166 1859 341 Adjusted Saturation Flow Rate ( s ), veh/h/ln 1730 1769 1585 1781 1781 1585 1689 1658 1547 1739 1658 1547 Queue Service Time ( g s ), s 35.3 34.0 31.8 30.0 15.5 1.2 40.0 71.0 10.7 19.3 70.0 24.9 Cycle Queue Clearance Time ( g c ), s 35.3 34.0 31.8 30.0 15.5 1.2 40.0 71.0 10.7 19.3 70.0 24.9 Green Ratio ( g/C )0.19 0.18 0.38 0.15 0.14 0.14 0.20 0.43 0.43 0.11 0.34 0.53 Capacity ( c ), veh/h 643 320 597 261 504 224 660 2149 668 184 1702 817 Volume-to-Capacity Ratio ( X )0.939 0.932 0.531 1.209 0.572 0.047 1.285 0.906 0.246 0.906 1.092 0.417 Back of Queue ( Q ), ft/ln (95 th percentile)622.8 641.8 477.8 852.6 297.2 22.4 1137. 3 962 183.3 390.5 1268.8 354.5 Back of Queue ( Q ), veh/ln ( 95 th percentile)24.5 25.3 18.8 33.6 11.7 0.9 43.7 37.0 7.1 15.0 48.8 13.6 Queue Storage Ratio ( RQ ) ( 95 th percentile)2.59 0.00 1.00 3.04 0.00 0.15 2.27 0.00 0.87 1.45 0.00 0.98 Uniform Delay ( d 1 ), s/veh 82.1 82.6 49.7 87.3 82.0 75.9 75.6 39.7 26.9 86.9 55.6 23.7 Incremental Delay ( d 2 ), s/veh 20.6 30.3 0.8 124.3 1.6 0.1 139.6 6.0 0.2 26.4 51.7 0.3 Initial Queue Delay ( d 3 ), s/veh 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Control Delay ( d ), s/veh 102.7 112.8 50.5 211.6 83.6 76.0 215.2 45.7 27.1 113.3 107.3 24.0 Level of Service (LOS)F F D F F E F D C F F C Approach Delay, s/veh / LOS 91.6 F 149.2 F 93.3 F 95.7 F Intersection Delay, s/veh / LOS 98.6 F Multimodal Results EB WB NB SB Pedestrian LOS Score / LOS 2.96 C 2.84 C 2.37 B 2.55 C Bicycle LOS Score / LOS 2.50 B 0.99 A 2.12 B 1.79 B Page 279 of 428 HCS Signalized Intersection Results Summary General Information Intersection Information Agency PTC Duration, h 0.250 Analyst #23-081 Analysis Date Nov 6, 2023 Area Type Other Jurisdiction SLC Time Period AM Peak PHF 0.94 Urban Street US 1 Analysis Year 2026 Analysis Period 1> 7:00 Intersection Prima Vista Blvd & US 1 File Name PV US 1 AM Future.xus Project Description Walton Ranch; Future Background Demand Information EB WB NB SB Approach Movement L T R L T R L T R L T R Demand ( v ), veh/h 428 170 659 258 221 73 340 1341 172 89 1558 184 Signal Information Green Yellow Red 12.1 3.9 65.4 27.6 2.4 40.0 4.8 4.8 4.8 4.0 0.0 4.0 2.0 2.0 2.0 3.0 0.0 3.0 1 2 3 4 5 6 7 8 Cycle, s 185.8 Reference Phase 2 Offset, s 0 Reference Point End Uncoordinated Yes Simult. Gap E/W On Force Mode Fixed Simult. Gap N/S On Timer Results EBL EBT WBL WBT NBL NBT SBL SBT Assigned Phase 3 8 7 4 1 6 5 2 Case Number 2.0 3.0 2.0 3.0 2.0 3.0 2.0 3.0 Phase Duration, s 34.6 47.0 37.0 49.4 29.6 82.9 18.9 72.2 Change Period, ( Y+R c ), s 7.0 7.0 7.0 7.0 6.8 6.8 6.8 6.8 Max Allow Headway ( MAH ), s 4.1 4.2 4.1 4.2 4.1 4.0 4.1 4.0 Queue Clearance Time ( g s ), s 26.0 42.0 30.4 12.1 21.4 41.2 12.0 61.1 Green Extension Time ( g e ), s 1.7 0.0 0.0 4.0 1.4 21.8 0.2 4.3 Phase Call Probability 1.00 1.00 1.00 1.00 1.00 1.00 0.99 1.00 Max Out Probability 0.01 1.00 1.00 0.24 0.00 0.67 0.00 0.92 Movement Group Results EB WB NB SB Approach Movement L T R L T R L T R L T R Assigned Movement 3 8 18 7 4 14 1 6 16 5 2 12 Adjusted Flow Rate ( v ), veh/h 455 340 478 274 235 78 362 1427 183 95 1657 196 Adjusted Saturation Flow Rate ( s ), veh/h/ln 1730 1737 1585 1781 1781 1585 1689 1658 1547 1739 1658 1547 Queue Service Time ( g s ), s 24.0 35.5 40.0 28.4 10.1 7.4 19.4 39.2 11.8 10.0 59.1 11.6 Cycle Queue Clearance Time ( g c ), s 24.0 35.5 40.0 28.4 10.1 7.4 19.4 39.2 11.8 10.0 59.1 11.6 Green Ratio ( g/C )0.15 0.22 0.34 0.16 0.23 0.23 0.12 0.41 0.41 0.07 0.35 0.50 Capacity ( c ), veh/h 515 374 536 288 812 361 415 2038 634 113 1751 775 Volume-to-Capacity Ratio ( X )0.885 0.910 0.892 0.954 0.290 0.215 0.873 0.700 0.289 0.836 0.947 0.253 Back of Queue ( Q ), ft/ln (95 th percentile)428.3 648.6 807.3 582 207.8 138.5 343.2 541.7 196.8 219.1 839.1 187.6 Back of Queue ( Q ), veh/ln ( 95 th percentile)16.9 25.5 31.8 22.9 8.2 5.5 13.2 20.8 7.6 8.4 32.3 7.2 Queue Storage Ratio ( RQ ) ( 95 th percentile)1.78 0.00 1.68 2.08 0.00 0.92 0.69 0.00 0.87 0.81 0.00 0.52 Uniform Delay ( d 1 ), s/veh 77.5 71.2 58.3 77.2 59.3 58.2 76.3 33.8 27.6 83.9 47.6 21.3 Incremental Delay ( d 2 ), s/veh 9.0 25.6 17.1 40.8 0.2 0.3 5.8 1.1 0.2 14.6 10.4 0.2 Initial Queue Delay ( d 3 ), s/veh 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Control Delay ( d ), s/veh 86.5 96.8 75.4 118.0 59.5 58.5 82.1 34.9 27.8 98.5 58.0 21.5 Level of Service (LOS)F F E F E E F C C F E C Approach Delay, s/veh / LOS 85.1 F 86.7 F 42.9 D 56.3 E Intersection Delay, s/veh / LOS 61.2 E Multimodal Results EB WB NB SB Pedestrian LOS Score / LOS 2.87 C 2.74 C 2.30 B 2.54 C Bicycle LOS Score / LOS 2.59 C 0.97 A 1.57 B 1.56 B Copyright © 2023 University of Florida, All Rights Reserved.HCS™ Streets Version 2023 Generated: 11/8/2023 3:13:05 PM Page 280 of 428 HCS Signalized Intersection Results Summary General Information Intersection Information Agency PTC Duration, h 0.250 Analyst #23-081 Analysis Date Nov 6, 2023 Area Type Other Jurisdiction SLC Time Period PM Peak PHF 0.95 Urban Street US 1 Analysis Year 2026 Analysis Period 1> 7:00 Intersection Prima Vista Blvd & US 1 File Name PV US 1 PM Future.xus Project Description Walton Ranch; Future Background Demand Information EB WB NB SB Approach Movement L T R L T R L T R L T R Demand ( v ), veh/h 591 244 475 353 313 89 830 1905 302 211 1819 396 Signal Information Green Yellow Red 28.3 4.9 70.0 30.0 2.3 30.7 4.8 4.8 4.8 4.0 4.0 4.0 2.0 2.0 2.0 3.0 3.0 3.0 1 2 3 4 5 6 7 8 Cycle, s 207.6 Reference Phase 2 Offset, s 0 Reference Point End Uncoordinated Yes Simult. Gap E/W On Force Mode Fixed Simult. Gap N/S On Timer Results EBL EBT WBL WBT NBL NBT SBL SBT Assigned Phase 3 8 7 4 1 6 5 2 Case Number 2.0 3.0 2.0 3.0 2.0 3.0 2.0 3.0 Phase Duration, s 46.3 47.0 37.0 37.7 46.8 88.5 35.1 76.8 Change Period, ( Y+R c ), s 7.0 7.0 7.0 7.0 6.8 6.8 6.8 6.8 Max Allow Headway ( MAH ), s 4.1 4.2 4.1 4.2 4.1 4.1 4.1 4.1 Queue Clearance Time ( g s ), s 38.9 42.0 32.0 20.0 42.0 83.7 28.2 72.0 Green Extension Time ( g e ), s 0.4 0.0 0.0 2.2 0.0 0.0 0.1 0.0 Phase Call Probability 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Max Out Probability 1.00 1.00 1.00 0.87 1.00 1.00 1.00 1.00 Movement Group Results EB WB NB SB Approach Movement L T R L T R L T R L T R Assigned Movement 3 8 18 7 4 14 1 6 16 5 2 12 Adjusted Flow Rate ( v ), veh/h 622 301 393 372 329 94 874 2005 255 222 1915 417 Adjusted Saturation Flow Rate ( s ), veh/h/ln 1730 1829 1585 1781 1781 1585 1689 1658 1547 1739 1658 1547 Queue Service Time ( g s ), s 36.9 33.0 40.0 30.0 18.0 11.1 40.0 81.7 20.8 26.2 70.0 34.3 Cycle Queue Clearance Time ( g c ), s 36.9 33.0 40.0 30.0 18.0 11.1 40.0 81.7 20.8 26.2 70.0 34.3 Green Ratio ( g/C )0.19 0.19 0.39 0.14 0.15 0.15 0.19 0.39 0.39 0.14 0.34 0.53 Capacity ( c ), veh/h 654 352 611 257 527 235 651 1958 609 237 1677 814 Volume-to-Capacity Ratio ( X )0.951 0.853 0.644 1.444 0.625 0.399 1.343 1.024 0.418 0.937 1.142 0.512 Back of Queue ( Q ), ft/ln (95 th percentile)654.1 614.9 612.3 1138. 1 338 208.1 1218. 9 1212. 2 310.9 521.3 1382.6 452.8 Back of Queue ( Q ), veh/ln ( 95 th percentile)25.8 24.2 24.1 44.8 13.3 8.2 46.9 46.6 12.0 20.0 53.2 17.4 Queue Storage Ratio ( RQ ) ( 95 th percentile)2.73 0.00 1.28 4.06 0.00 1.39 2.44 0.00 1.38 1.93 0.00 1.26 Uniform Delay ( d 1 ), s/veh 83.2 81.0 52.1 88.8 83.0 80.1 77.1 49.3 34.9 84.1 57.1 26.1 Incremental Delay ( d 2 ), s/veh 23.2 17.9 2.3 220.2 2.3 1.1 164.4 26.8 0.5 39.0 71.5 0.5 Initial Queue Delay ( d 3 ), s/veh 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Control Delay ( d ), s/veh 106.4 98.9 54.5 309.0 85.3 81.2 241.5 76.1 35.3 123.1 128.6 26.6 Level of Service (LOS)F F D F F F F F D F F C Approach Delay, s/veh / LOS 89.2 F 189.4 F 118.9 F 111.5 F Intersection Delay, s/veh / LOS 118.6 F Multimodal Results EB WB NB SB Pedestrian LOS Score / LOS 2.96 C 2.76 C 2.30 B 2.55 C Bicycle LOS Score / LOS 2.66 C 1.14 A 2.21 B 1.89 B Page 281 of 428 HCS Signalized Intersection Results Summary General Information Intersection Information Agency PTC Duration, h 0.250 Analyst #23-081 Analysis Date Nov 6, 2023 Area Type Other Jurisdiction SLC Time Period AM Peak PHF 0.94 Urban Street US 1 Analysis Year 2026 Analysis Period 1> 7:00 Intersection Prima Vista Blvd & US 1 File Name PV US 1 AM Future w-Imp.xus Project Description Walton Ranch; Future w/Improve. Demand Information EB WB NB SB Approach Movement L T R L T R L T R L T R Demand ( v ), veh/h 428 170 659 258 221 73 340 1341 172 89 1558 184 Signal Information Green Yellow Red 11.1 3.1 63.8 16.1 2.4 30.6 4.8 4.8 4.8 4.0 4.0 4.0 2.0 2.0 2.0 3.0 3.0 3.0 1 2 3 4 5 6 7 8 Cycle, s 168.4 Reference Phase 2 Offset, s 0 Reference Point End Uncoordinated Yes Simult. Gap E/W On Force Mode Fixed Simult. Gap N/S On Timer Results EBL EBT WBL WBT NBL NBT SBL SBT Assigned Phase 3 8 7 4 1 6 5 2 Case Number 2.0 3.0 2.0 3.0 2.0 3.0 2.0 3.0 Phase Duration, s 32.4 47.0 23.1 37.6 27.8 80.4 17.9 70.6 Change Period, ( Y+R c ), s 7.0 7.0 7.0 7.0 6.8 6.8 6.8 6.8 Max Allow Headway ( MAH ), s 4.1 4.2 4.1 4.2 4.1 4.0 4.1 4.0 Queue Clearance Time ( g s ), s 23.7 42.0 15.1 11.7 19.6 34.6 11.0 52.0 Green Extension Time ( g e ), s 1.8 0.0 0.9 4.1 1.4 25.3 0.2 11.8 Phase Call Probability 1.00 1.00 1.00 1.00 1.00 1.00 0.99 1.00 Max Out Probability 0.00 1.00 0.00 0.23 0.00 0.60 0.00 0.80 Movement Group Results EB WB NB SB Approach Movement L T R L T R L T R L T R Assigned Movement 3 8 18 7 4 14 1 6 16 5 2 12 Adjusted Flow Rate ( v ), veh/h 455 340 478 274 235 78 362 1427 183 95 1657 196 Adjusted Saturation Flow Rate ( s ), veh/h/ln 1730 1737 1585 1730 1781 1585 1689 1658 1547 1739 1658 1547 Queue Service Time ( g s ), s 21.7 31.3 40.0 13.1 9.7 6.5 17.6 32.6 8.2 9.0 50.0 9.6 Cycle Queue Clearance Time ( g c ), s 21.7 31.3 40.0 13.1 9.7 6.5 17.6 32.6 8.2 9.0 50.0 9.6 Green Ratio ( g/C )0.15 0.24 0.36 0.10 0.18 0.25 0.12 0.44 0.53 0.07 0.38 0.53 Capacity ( c ), veh/h 522 412 574 330 648 393 421 2175 824 115 1883 820 Volume-to-Capacity Ratio ( X )0.871 0.825 0.833 0.831 0.363 0.198 0.860 0.656 0.222 0.825 0.880 0.239 Back of Queue ( Q ), ft/ln (95 th percentile)387.6 549.9 691.5 257.6 201.2 120.9 312.9 444 128.5 202.1 682.1 151.2 Back of Queue ( Q ), veh/ln ( 95 th percentile)15.3 21.6 27.2 10.1 7.9 4.8 12.0 17.1 4.9 7.8 26.2 5.8 Queue Storage Ratio ( RQ ) ( 95 th percentile)1.62 0.00 1.44 0.68 0.00 0.81 0.63 0.00 0.57 0.75 0.00 0.42 Uniform Delay ( d 1 ), s/veh 69.9 60.9 49.1 74.9 60.4 50.1 68.8 26.6 15.0 75.8 38.3 16.6 Incremental Delay ( d 2 ), s/veh 6.3 12.8 10.2 5.4 0.3 0.2 5.2 0.7 0.1 13.6 4.5 0.1 Initial Queue Delay ( d 3 ), s/veh 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Control Delay ( d ), s/veh 76.2 73.7 59.2 80.3 60.7 50.3 74.0 27.3 15.2 89.4 42.7 16.8 Level of Service (LOS)E E E F E D E C B F D B Approach Delay, s/veh / LOS 69.2 E 68.5 E 34.7 C 42.4 D Intersection Delay, s/veh / LOS 48.3 D Multimodal Results EB WB NB SB Pedestrian LOS Score / LOS 2.86 C 2.74 C 2.44 B 2.54 C Bicycle LOS Score / LOS 2.59 C 0.97 A 1.57 B 1.56 B Copyright © 2023 University of Florida, All Rights Reserved.HCS™ Streets Version 2023 Generated: 11/8/2023 3:39:22 PM Page 282 of 428 HCS Signalized Intersection Results Summary General Information Intersection Information Agency PTC Duration, h 0.250 Analyst #23-081 Analysis Date Nov 6, 2023 Area Type Other Jurisdiction SLC Time Period PM Peak PHF 0.95 Urban Street US 1 Analysis Year 2026 Analysis Period 1> 7:00 Intersection Prima Vista Blvd & US 1 File Name PV US 1 PM Future Improve.xus Project Description Walton Ranch; Future w/Improvements Demand Information EB WB NB SB Approach Movement L T R L T R L T R L T R Demand ( v ), veh/h 591 244 475 353 313 89 830 1905 302 211 1819 396 Signal Information Green Yellow Red 14.5 13.6 57.8 22.5 7.1 24.8 4.8 4.8 4.8 4.0 4.0 4.0 2.0 2.0 2.0 3.0 3.0 3.0 1 2 3 4 5 6 7 8 Cycle, s 181.7 Reference Phase 2 Offset, s 0 Reference Point End Uncoordinated Yes Simult. Gap E/W On Force Mode Fixed Simult. Gap N/S On Timer Results EBL EBT WBL WBT NBL NBT SBL SBT Assigned Phase 3 8 7 4 1 6 5 2 Case Number 2.0 3.0 2.0 3.0 2.0 3.0 2.0 3.0 Phase Duration, s 43.6 45.8 29.5 31.8 41.7 85.1 21.3 64.6 Change Period, ( Y+R c ), s 7.0 7.0 7.0 7.0 6.8 6.8 6.8 6.8 Max Allow Headway ( MAH ), s 4.1 4.2 4.1 4.2 4.1 4.1 4.1 4.1 Queue Clearance Time ( g s ), s 33.8 37.6 21.2 18.0 32.3 41.2 13.7 51.1 Green Extension Time ( g e ), s 2.7 1.2 1.3 2.8 2.6 22.1 0.7 6.7 Phase Call Probability 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Max Out Probability 0.00 1.00 0.01 0.62 0.40 0.92 0.00 0.96 Movement Group Results EB WB NB SB Approach Movement L T R L T R L T R L T R Assigned Movement 3 8 18 7 4 14 1 6 16 5 2 12 Adjusted Flow Rate ( v ), veh/h 622 301 393 372 329 94 874 2005 255 222 1915 417 Adjusted Saturation Flow Rate ( s ), veh/h/ln 1730 1829 1585 1730 1781 1585 1689 1658 1547 1689 1658 1547 Queue Service Time ( g s ), s 31.8 28.1 35.6 19.2 16.0 9.0 30.3 39.2 12.8 11.7 49.1 31.0 Cycle Queue Clearance Time ( g c ), s 31.8 28.1 35.6 19.2 16.0 9.0 30.3 39.2 12.8 11.7 49.1 31.0 Green Ratio ( g/C )0.20 0.21 0.41 0.12 0.14 0.22 0.19 0.43 0.55 0.08 0.32 0.52 Capacity ( c ), veh/h 696 391 643 428 485 342 973 2857 858 269 2112 804 Volume-to-Capacity Ratio ( X )0.893 0.769 0.611 0.868 0.679 0.274 0.898 0.702 0.297 0.826 0.907 0.518 Back of Queue ( Q ), ft/ln (95 th percentile)535.4 513.7 522.1 353.8 307.9 167.8 498.5 530.1 194.4 231.6 700 406.1 Back of Queue ( Q ), veh/ln ( 95 th percentile)21.1 20.2 20.6 13.9 12.1 6.6 19.2 20.4 7.5 8.9 26.9 15.6 Queue Storage Ratio ( RQ ) ( 95 th percentile)2.23 0.00 1.09 0.93 0.00 0.58 1.00 0.00 0.86 0.86 0.00 1.13 Uniform Delay ( d 1 ), s/veh 70.7 67.2 42.7 78.2 74.7 59.4 65.9 30.3 15.6 80.0 49.8 24.0 Incremental Delay ( d 2 ), s/veh 6.9 8.5 1.6 7.5 3.7 0.4 9.0 0.8 0.2 6.3 5.1 0.5 Initial Queue Delay ( d 3 ), s/veh 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Control Delay ( d ), s/veh 77.6 75.7 44.3 85.7 78.4 59.8 74.9 31.1 15.8 86.3 54.9 24.5 Level of Service (LOS)E E D F E E E C B F D C Approach Delay, s/veh / LOS 67.2 E 79.6 E 42.1 D 52.7 D Intersection Delay, s/veh / LOS 53.6 D Multimodal Results EB WB NB SB Pedestrian LOS Score / LOS 3.29 C 3.10 C 2.59 C 2.69 C Bicycle LOS Score / LOS 2.66 C 1.14 A 1.78 B 1.54 B Copyright © 2023 University of Florida, All Rights Reserved.HCS™ Streets Version 2023 Generated: 11/8/2023 3:07:00 PM Page 283 of 428 HCS Signalized Intersection Results Summary General Information Intersection Information Agency PTC Duration, h 0.250 Analyst #23-081 Analysis Date Mar 20, 2024 Area Type Other Jurisdiction SLC Time Period AM Peak PHF 0.94 Urban Street US 1 Analysis Year 2026 Analysis Period 1> 7:00 Intersection Prima Vista Blvd & US 1 File Name PV US 1 AM Buildout.xus Project Description Walton Ranch; Buildout Demand Information EB WB NB SB Approach Movement L T R L T R L T R L T R Demand ( v ), veh/h 428 175 659 288 236 79 340 1341 183 91 1558 184 Signal Information Green Yellow Red 12.3 3.7 65.4 27.6 2.4 40.0 4.8 4.8 4.8 4.0 0.0 4.0 2.0 2.0 2.0 3.0 0.0 3.0 1 2 3 4 5 6 7 8 Cycle, s 185.8 Reference Phase 2 Offset, s 0 Reference Point End Uncoordinated Yes Simult. Gap E/W On Force Mode Fixed Simult. Gap N/S On Timer Results EBL EBT WBL WBT NBL NBT SBL SBT Assigned Phase 3 8 7 4 1 6 5 2 Case Number 2.0 3.0 2.0 3.0 2.0 3.0 2.0 3.0 Phase Duration, s 34.6 47.0 37.0 49.4 29.6 82.7 19.1 72.2 Change Period, ( Y+R c ), s 7.0 7.0 7.0 7.0 6.8 6.8 6.8 6.8 Max Allow Headway ( MAH ), s 4.1 4.2 4.1 4.2 4.1 4.0 4.1 4.0 Queue Clearance Time ( g s ), s 26.0 42.0 32.0 12.9 21.4 41.3 12.2 61.1 Green Extension Time ( g e ), s 1.7 0.0 0.0 4.0 1.4 21.7 0.2 4.3 Phase Call Probability 1.00 1.00 1.00 1.00 1.00 1.00 0.99 1.00 Max Out Probability 0.01 1.00 1.00 0.28 0.00 0.67 0.00 0.92 Movement Group Results EB WB NB SB Approach Movement L T R L T R L T R L T R Assigned Movement 3 8 18 7 4 14 1 6 16 5 2 12 Adjusted Flow Rate ( v ), veh/h 455 345 478 306 251 84 362 1427 195 97 1657 196 Adjusted Saturation Flow Rate ( s ), veh/h/ln 1730 1739 1585 1781 1781 1585 1689 1658 1547 1739 1658 1547 Queue Service Time ( g s ), s 24.0 36.2 40.0 30.0 10.9 8.0 19.4 39.3 12.8 10.2 59.1 11.6 Cycle Queue Clearance Time ( g c ), s 24.0 36.2 40.0 30.0 10.9 8.0 19.4 39.3 12.8 10.2 59.1 11.6 Green Ratio ( g/C )0.15 0.22 0.34 0.16 0.23 0.23 0.12 0.41 0.41 0.07 0.35 0.50 Capacity ( c ), veh/h 515 374 536 288 812 361 415 2031 632 115 1751 775 Volume-to-Capacity Ratio ( X )0.885 0.923 0.892 1.065 0.309 0.233 0.873 0.702 0.308 0.839 0.947 0.253 Back of Queue ( Q ), ft/ln (95 th percentile)428.3 665.3 807.2 701.3 219.7 150.5 343.2 544.4 208.3 222.7 839.2 187.6 Back of Queue ( Q ), veh/ln ( 95 th percentile)16.9 26.2 31.8 27.6 8.6 5.9 13.2 20.9 8.0 8.6 32.3 7.2 Queue Storage Ratio ( RQ ) ( 95 th percentile)1.78 0.00 1.68 2.50 0.00 1.00 0.69 0.00 0.93 0.82 0.00 0.52 Uniform Delay ( d 1 ), s/veh 77.5 71.4 58.3 77.9 59.6 58.5 76.3 34.0 28.0 83.7 47.6 21.3 Incremental Delay ( d 2 ), s/veh 9.0 28.0 17.1 71.4 0.2 0.3 5.8 1.1 0.3 14.6 10.4 0.2 Initial Queue Delay ( d 3 ), s/veh 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Control Delay ( d ), s/veh 86.5 99.4 75.4 149.3 59.8 58.8 82.1 35.1 28.2 98.3 58.1 21.5 Level of Service (LOS)F F E F E E F D C F E C Approach Delay, s/veh / LOS 85.8 F 102.4 F 43.0 D 56.4 E Intersection Delay, s/veh / LOS 63.3 E Multimodal Results EB WB NB SB Pedestrian LOS Score / LOS 2.87 C 2.74 C 2.30 B 2.54 C Bicycle LOS Score / LOS 2.60 C 1.02 A 1.58 B 1.56 B Copyright © 2024 University of Florida, All Rights Reserved.HCS™ Streets Version 2023 Generated: 3/20/2024 2:26:39 PM Page 284 of 428 HCS Signalized Intersection Results Summary General Information Intersection Information Agency PTC Duration, h 0.250 Analyst #23-081 Analysis Date Mar 20, 2024 Area Type Other Jurisdiction SLC Time Period PM Peak PHF 0.95 Urban Street US 1 Analysis Year 2026 Analysis Period 1> 7:00 Intersection Prima Vista Blvd & US 1 File Name PV US 1 PM Buildout.xus Project Description Walton Ranch; Buildout Demand Information EB WB NB SB Approach Movement L T R L T R L T R L T R Demand ( v ), veh/h 591 261 475 373 323 93 830 1905 337 218 1819 396 Signal Information Green Yellow Red 29.1 4.1 70.0 30.0 2.3 30.7 4.8 4.8 4.8 4.0 4.0 4.0 2.0 2.0 2.0 3.0 3.0 3.0 1 2 3 4 5 6 7 8 Cycle, s 207.6 Reference Phase 2 Offset, s 0 Reference Point End Uncoordinated Yes Simult. Gap E/W On Force Mode Fixed Simult. Gap N/S On Timer Results EBL EBT WBL WBT NBL NBT SBL SBT Assigned Phase 3 8 7 4 1 6 5 2 Case Number 2.0 3.0 2.0 3.0 2.0 3.0 2.0 3.0 Phase Duration, s 46.3 47.0 37.0 37.7 46.8 87.7 35.9 76.8 Change Period, ( Y+R c ), s 7.0 7.0 7.0 7.0 6.8 6.8 6.8 6.8 Max Allow Headway ( MAH ), s 4.1 4.2 4.1 4.2 4.1 4.1 4.1 4.1 Queue Clearance Time ( g s ), s 38.9 42.0 32.0 20.7 42.0 82.9 29.0 72.0 Green Extension Time ( g e ), s 0.4 0.0 0.0 2.0 0.0 0.0 0.1 0.0 Phase Call Probability 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Max Out Probability 1.00 1.00 1.00 0.97 1.00 1.00 1.00 1.00 Movement Group Results EB WB NB SB Approach Movement L T R L T R L T R L T R Assigned Movement 3 8 18 7 4 14 1 6 16 5 2 12 Adjusted Flow Rate ( v ), veh/h 622 318 393 393 340 98 874 2005 292 229 1915 417 Adjusted Saturation Flow Rate ( s ), veh/h/ln 1730 1831 1585 1781 1781 1585 1689 1658 1547 1739 1658 1547 Queue Service Time ( g s ), s 36.9 35.3 40.0 30.0 18.7 11.6 40.0 80.9 25.1 27.0 70.0 34.3 Cycle Queue Clearance Time ( g c ), s 36.9 35.3 40.0 30.0 18.7 11.6 40.0 80.9 25.1 27.0 70.0 34.3 Green Ratio ( g/C )0.19 0.19 0.39 0.14 0.15 0.15 0.19 0.39 0.39 0.14 0.34 0.53 Capacity ( c ), veh/h 654 353 611 257 527 235 651 1938 603 244 1677 814 Volume-to-Capacity Ratio ( X )0.951 0.902 0.644 1.525 0.645 0.417 1.343 1.035 0.484 0.941 1.142 0.512 Back of Queue ( Q ), ft/ln (95 th percentile)654.1 671 612.3 1242. 5 348.5 215.9 1218. 9 1231. 3 363.4 538 1382.6 452.8 Back of Queue ( Q ), veh/ln ( 95 th percentile)25.8 26.4 24.1 48.9 13.7 8.5 46.9 47.4 14.0 20.7 53.2 17.4 Queue Storage Ratio ( RQ ) ( 95 th percentile)2.73 0.00 1.28 4.44 0.00 1.44 2.44 0.00 1.61 1.99 0.00 1.26 Uniform Delay ( d 1 ), s/veh 83.2 81.9 52.1 88.8 83.3 80.3 77.1 49.9 36.5 83.6 57.1 26.1 Incremental Delay ( d 2 ), s/veh 23.2 25.3 2.3 255.2 2.7 1.2 164.4 30.0 0.6 40.4 71.5 0.5 Initial Queue Delay ( d 3 ), s/veh 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Control Delay ( d ), s/veh 106.4 107.2 54.5 344.0 86.0 81.5 241.5 79.9 37.1 123.9 128.6 26.6 Level of Service (LOS)F F D F F F F F D F F C Approach Delay, s/veh / LOS 91.3 F 207.4 F 120.5 F 111.6 F Intersection Delay, s/veh / LOS 121.8 F Multimodal Results EB WB NB SB Pedestrian LOS Score / LOS 2.96 C 2.76 C 2.30 B 2.55 C Bicycle LOS Score / LOS 2.69 C 1.17 A 2.23 B 1.90 B Page 285 of 428 HCS Signalized Intersection Results Summary General Information Intersection Information Agency PTC Duration, h 0.250 Analyst #23-081 Analysis Date Mar 20, 2024 Area Type Other Jurisdiction SLC Time Period AM Peak PHF 0.94 Urban Street US 1 Analysis Year 2026 Analysis Period 1> 7:00 Intersection Prima Vista Blvd & US 1 File Name PV US 1 AM Buildout w-Imp.xus Project Description Walton Ranch; Buildout w/Improve. Demand Information EB WB NB SB Approach Movement L T R L T R L T R L T R Demand ( v ), veh/h 428 175 659 288 236 79 340 1341 183 91 1558 184 Signal Information Green Yellow Red 11.5 3.0 64.0 17.9 0.9 32.1 4.8 4.8 4.8 4.0 4.0 4.0 2.0 2.0 2.0 3.0 3.0 3.0 1 2 3 4 5 6 7 8 Cycle, s 170.7 Reference Phase 2 Offset, s 0 Reference Point End Uncoordinated Yes Simult. Gap E/W On Force Mode Fixed Simult. Gap N/S On Timer Results EBL EBT WBL WBT NBL NBT SBL SBT Assigned Phase 3 8 7 4 1 6 5 2 Case Number 2.0 3.0 2.0 3.0 2.0 3.0 2.0 3.0 Phase Duration, s 32.7 47.0 24.9 39.1 28.0 80.6 18.3 70.8 Change Period, ( Y+R c ), s 7.0 7.0 7.0 7.0 6.8 6.8 6.8 6.8 Max Allow Headway ( MAH ), s 4.1 4.2 4.1 4.2 4.1 4.0 4.1 4.0 Queue Clearance Time ( g s ), s 24.0 42.0 16.9 12.5 19.8 35.6 11.3 53.2 Green Extension Time ( g e ), s 1.7 0.0 1.0 4.1 1.4 24.9 0.2 10.8 Phase Call Probability 1.00 1.00 1.00 1.00 1.00 1.00 0.99 1.00 Max Out Probability 0.00 1.00 0.00 0.27 0.00 0.61 0.00 0.81 Movement Group Results EB WB NB SB Approach Movement L T R L T R L T R L T R Assigned Movement 3 8 18 7 4 14 1 6 16 5 2 12 Adjusted Flow Rate ( v ), veh/h 455 345 478 306 251 84 362 1427 195 97 1657 196 Adjusted Saturation Flow Rate ( s ), veh/h/ln 1730 1739 1585 1730 1781 1585 1689 1658 1547 1739 1658 1547 Queue Service Time ( g s ), s 22.0 32.4 40.0 14.9 10.5 7.1 17.8 33.6 8.9 9.3 51.2 9.9 Cycle Queue Clearance Time ( g c ), s 22.0 32.4 40.0 14.9 10.5 7.1 17.8 33.6 8.9 9.3 51.2 9.9 Green Ratio ( g/C )0.15 0.23 0.36 0.10 0.19 0.26 0.12 0.43 0.54 0.07 0.38 0.53 Capacity ( c ), veh/h 521 407 568 362 670 405 420 2149 831 117 1865 814 Volume-to-Capacity Ratio ( X )0.873 0.848 0.841 0.846 0.374 0.208 0.862 0.664 0.234 0.829 0.889 0.241 Back of Queue ( Q ), ft/ln (95 th percentile)392.8 574.7 706.2 284.5 213.5 131.8 316.8 458.5 139.6 207.7 701.2 155.9 Back of Queue ( Q ), veh/ln ( 95 th percentile)15.5 22.6 27.8 11.2 8.4 5.2 12.2 17.6 5.4 8.0 27.0 6.0 Queue Storage Ratio ( RQ ) ( 95 th percentile)1.64 0.00 1.47 0.75 0.00 0.88 0.63 0.00 0.62 0.77 0.00 0.43 Uniform Delay ( d 1 ), s/veh 70.9 62.5 50.3 75.1 60.5 50.0 69.8 27.7 15.2 76.7 39.5 17.2 Incremental Delay ( d 2 ), s/veh 6.7 15.3 10.9 5.6 0.3 0.3 5.3 0.8 0.1 13.7 4.9 0.2 Initial Queue Delay ( d 3 ), s/veh 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Control Delay ( d ), s/veh 77.6 77.8 61.2 80.7 60.9 50.2 75.1 28.4 15.4 90.4 44.4 17.4 Level of Service (LOS)E E E F E D E C B F D B Approach Delay, s/veh / LOS 71.5 E 68.9 E 35.7 D 44.0 D Intersection Delay, s/veh / LOS 49.9 D Multimodal Results EB WB NB SB Pedestrian LOS Score / LOS 2.86 C 2.74 C 2.44 B 2.54 C Bicycle LOS Score / LOS 2.60 C 1.02 A 1.58 B 1.56 B Copyright © 2024 University of Florida, All Rights Reserved.HCS™ Streets Version 2023 Generated: 3/20/2024 2:28:52 PM Page 286 of 428 HCS Signalized Intersection Results Summary General Information Intersection Information Agency PTC Duration, h 0.250 Analyst #23-081 Analysis Date Mar 20, 2024 Area Type Other Jurisdiction SLC Time Period PM Peak PHF 0.95 Urban Street US 1 Analysis Year 2026 Analysis Period 1> 7:00 Intersection Prima Vista Blvd & US 1 File Name PV US 1 PM Buildout Improve.xus Project Description Walton Ranch; Buildout w/Improve. Demand Information EB WB NB SB Approach Movement L T R L T R L T R L T R Demand ( v ), veh/h 591 261 475 373 323 93 830 1905 337 218 1819 396 Signal Information Green Yellow Red 15.0 13.4 58.2 23.8 6.1 25.7 4.8 4.8 4.8 4.0 4.0 4.0 2.0 2.0 2.0 3.0 3.0 3.0 1 2 3 4 5 6 7 8 Cycle, s 183.6 Reference Phase 2 Offset, s 0 Reference Point End Uncoordinated Yes Simult. Gap E/W On Force Mode Fixed Simult. Gap N/S On Timer Results EBL EBT WBL WBT NBL NBT SBL SBT Assigned Phase 3 8 7 4 1 6 5 2 Case Number 2.0 3.0 2.0 3.0 2.0 3.0 2.0 3.0 Phase Duration, s 43.9 45.8 30.8 32.7 42.0 85.1 21.8 65.0 Change Period, ( Y+R c ), s 7.0 7.0 7.0 7.0 6.8 6.8 6.8 6.8 Max Allow Headway ( MAH ), s 4.1 4.2 4.1 4.2 4.1 4.1 4.1 4.1 Queue Clearance Time ( g s ), s 34.2 38.2 22.5 18.7 32.6 42.1 14.2 51.8 Green Extension Time ( g e ), s 2.7 0.6 1.3 2.7 2.5 21.3 0.8 6.4 Phase Call Probability 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Max Out Probability 0.00 1.00 0.01 0.70 0.44 0.92 0.00 0.96 Movement Group Results EB WB NB SB Approach Movement L T R L T R L T R L T R Assigned Movement 3 8 18 7 4 14 1 6 16 5 2 12 Adjusted Flow Rate ( v ), veh/h 622 318 393 393 340 98 874 2005 292 229 1915 417 Adjusted Saturation Flow Rate ( s ), veh/h/ln 1730 1831 1585 1730 1781 1585 1689 1658 1547 1689 1658 1547 Queue Service Time ( g s ), s 32.2 30.5 36.2 20.5 16.7 9.4 30.6 40.1 15.4 12.2 49.8 31.5 Cycle Queue Clearance Time ( g c ), s 32.2 30.5 36.2 20.5 16.7 9.4 30.6 40.1 15.4 12.2 49.8 31.5 Green Ratio ( g/C )0.20 0.21 0.40 0.13 0.14 0.22 0.19 0.43 0.56 0.08 0.32 0.52 Capacity ( c ), veh/h 696 387 639 449 499 352 970 2830 861 276 2102 802 Volume-to-Capacity Ratio ( X )0.894 0.822 0.615 0.875 0.681 0.278 0.900 0.709 0.339 0.831 0.911 0.520 Back of Queue ( Q ), ft/ln (95 th percentile)541.4 563.1 529.8 376 318.4 176.4 504.7 543.5 222.6 239.6 711.3 412.5 Back of Queue ( Q ), veh/ln ( 95 th percentile)21.3 22.2 20.9 14.8 12.5 6.9 19.4 20.9 8.6 9.2 27.4 15.9 Queue Storage Ratio ( RQ ) ( 95 th percentile)2.26 0.00 1.10 0.99 0.00 0.61 1.01 0.00 0.99 0.89 0.00 1.15 Uniform Delay ( d 1 ), s/veh 71.5 69.1 43.5 78.4 75.1 59.3 66.7 31.3 16.1 80.6 50.6 24.4 Incremental Delay ( d 2 ), s/veh 7.1 12.7 1.7 8.8 3.8 0.4 9.3 0.8 0.2 6.4 5.5 0.5 Initial Queue Delay ( d 3 ), s/veh 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Control Delay ( d ), s/veh 78.6 81.8 45.2 87.3 78.8 59.7 76.0 32.2 16.4 87.0 56.1 25.0 Level of Service (LOS)E F D F E E E C B F E C Approach Delay, s/veh / LOS 69.5 E 80.6 F 42.8 D 53.8 D Intersection Delay, s/veh / LOS 54.8 D Multimodal Results EB WB NB SB Pedestrian LOS Score / LOS 3.29 C 3.10 C 2.59 C 2.69 C Bicycle LOS Score / LOS 2.69 C 1.17 A 1.80 B 1.54 B Copyright © 2024 University of Florida, All Rights Reserved.HCS™ Streets Version 2023 Generated: 3/20/2024 2:37:32 PM Page 287 of 428 Page 288 of 428 Intersections 23-081 3-19-24 Historic Growth Rate =2.00% Nominal Growth Rate =1.00% Peak Season =1.17 Buildout Year = 2026 Years =3 Northbound Southbound Eastbound Westbound LT Thru RT LT Thru RT LT Thru RT LT Thru RT Existing Volume (10/26/23)30 14 0 0 14 145 142 0 14 0 0 0 Peak Season Volume 35 16 0 0 16 170 166 0 16 0 0 0 SUM Historic Growth 2 1 0 0 1 10 10 0 1 0 0 0 25 Nominal Growth 1 0 0 0 0 5 5 0 0 0 0 0 Approved Projects*151 0 0 0 0 29 8 0 41 0 0 0 Highest Inters. Growth 152 0 0 0 0 34 13 0 41 0 0 0 Background Traffic 187 16 0 0 16 204 179 0 57 0 0 0 % Project Traffic 70% 28% 0% 0% 28% 0% 0% 0% 70% 0% 0% 0% Direction out out out in in in in in in in in in Project Traffic 53 21 0 0 8 0 0 0 19 0 0 0 Total 240 37 0 0 24 204 179 0 76 0 0 0 Northbound Southbound Eastbound Westbound LT Thru RT LT Thru RT LT Thru RT LT Thru RT Existing Volume (10/26/23)26 9 0 0 18 70 56 0 38 0 0 0 Peak Season Volume 30 11 0 0 21 82 66 0 44 0 0 0 SUM Historic Growth 2 1 0 0 1 5 4 0 3 0 0 0 16 Nominal Growth 1 0 0 0 1 2 2 0 1 0 0 0 Approved Projects*86 0 0 0 0 16 24 0 158 0 0 0 Highest Inters. Growth 87 0 0 0 1 18 26 0 159 0 0 0 Background Traffic 117 11 0 0 22 100 92 0 203 0 0 0 % Project Traffic 70% 28% 0% 0% 28% 0% 0% 0% 70% 0% 0% 0% Direction out out out in in in in in in in in in Project Traffic 36 14 0 0 24 0 0 0 60 0 0 0 Total 153 25 0 0 46 100 92 0 264 0 0 0 * Prima Vista Commons and Silver Oaks 3/19/2024 13:36 240 PM Peak Hour Intersection Volume Development 291 INTERSECTION ANALYSIS SHEET Walton Ranch Prima Vista Pkwy & Lennard Rd Ext. (Existing Geometrics w/Project) AM Peak Hour Intersection Volume Development Page 289 of 428 HCS All-Way Stop Control Report General and Site Information Lanes Analyst #23-081 Agency/Co.PTC Date Performed 3/21/24 Analysis Year 2023 Analysis Time Period (hrs)0.25 Time Analyzed AM Peak Hour Project Description Walton Ranch; Existing Intersection Prima Vista & Lennard Rd Jurisdiction SLC East/West Street Prima Vista Pkwy North/South Street Lennard Rd Ext. Peak Hour Factor 0.68 Turning Movement Demand Volumes Approach Eastbound Westbound Northbound Southbound Movement L T R L T R L T R L T R Volume (veh/h)166 16 35 16 16 170 % Thrus in Shared Lane Lane Flow Rate and Adjustments Approach Eastbound Westbound Northbound Southbound Lane L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 Configuration L R LT TR Flow Rate, v (veh/h)244 24 75 274 Percent Heavy Vehicles 2 2 2 2 Initial Departure Headway, hd (s)3.20 3.20 3.20 3.20 Initial Degree of Utilization, x 0.217 0.021 0.067 0.243 Final Departure Headway, hd (s)5.84 4.64 5.19 4.27 Final Degree of Utilization, x 0.396 0.030 0.108 0.325 Move-Up Time, m (s)2.3 2.3 2.0 2.0 Service Time, ts (s)3.54 2.34 3.19 2.27 Capacity, Delay and Level of Service Approach Eastbound Westbound Northbound Southbound Lane L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 Configuration L R LT TR Flow Rate, v (veh/h)244 24 75 274 Capacity (veh/h)616 776 694 842 95% Queue Length, Q₉₅ (veh)1.9 0.1 0.4 1.4 Control Delay (s/veh)12.3 7.5 8.8 9.3 Level of Service, LOS B A A A Approach Delay (s/veh) | LOS 11.9 B 8.8 A 9.3 A Intersection Delay (s/veh) | LOS 10.4 B Copyright © 2024 University of Florida. All Rights Reserved.HCS™AWSC Version 2023 Generated: 3/21/2024 12:13:47 PMPV Lennard AM exist.xaw Page 290 of 428 HCS All-Way Stop Control Report General and Site Information Lanes Analyst #23-081 Agency/Co.PTC Date Performed 3/21/24 Analysis Year 2023 Analysis Time Period (hrs)0.25 Time Analyzed PM Peak Hour Project Description Walton Ranch; Existing Intersection Prima Vista & Lennard Rd Jurisdiction SLC East/West Street Prima Vista Pkwy North/South Street Lennard Rd Ext. Peak Hour Factor 0.81 Turning Movement Demand Volumes Approach Eastbound Westbound Northbound Southbound Movement L T R L T R L T R L T R Volume (veh/h)66 44 30 11 21 82 % Thrus in Shared Lane Lane Flow Rate and Adjustments Approach Eastbound Westbound Northbound Southbound Lane L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 Configuration L R LT TR Flow Rate, v (veh/h)81 54 51 127 Percent Heavy Vehicles 2 2 2 2 Initial Departure Headway, hd (s)3.20 3.20 3.20 3.20 Initial Degree of Utilization, x 0.072 0.048 0.045 0.113 Final Departure Headway, hd (s)5.41 4.21 4.54 3.85 Final Degree of Utilization, x 0.123 0.064 0.064 0.136 Move-Up Time, m (s)2.3 2.3 2.0 2.0 Service Time, ts (s)3.11 1.91 2.54 1.85 Capacity, Delay and Level of Service Approach Eastbound Westbound Northbound Southbound Lane L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 Configuration L R LT TR Flow Rate, v (veh/h)81 54 51 127 Capacity (veh/h)665 855 793 935 95% Queue Length, Q₉₅ (veh)0.4 0.2 0.2 0.5 Control Delay (s/veh)8.9 7.2 7.8 7.5 Level of Service, LOS A A A A Approach Delay (s/veh) | LOS 8.2 A 7.8 A 7.5 A Intersection Delay (s/veh) | LOS 7.8 A Copyright © 2024 University of Florida. All Rights Reserved.HCS™AWSC Version 2023 Generated: 3/21/2024 12:22:10 PMPV Lennard PM exist.xaw Page 291 of 428 HCS All-Way Stop Control Report General and Site Information Lanes Analyst #23-081 Agency/Co.PTC Date Performed 11/6/2023 Analysis Year 2026 Analysis Time Period (hrs)0.25 Time Analyzed AM Peak Hour Project Description Walton Ranch; Future Intersection Prima Vista & Lennard Rd Jurisdiction SLC East/West Street Prima Vista Pkwy North/South Street Lennard Rd Ext. Peak Hour Factor 0.68 Turning Movement Demand Volumes Approach Eastbound Westbound Northbound Southbound Movement L T R L T R L T R L T R Volume (veh/h)179 57 187 16 16 204 % Thrus in Shared Lane Lane Flow Rate and Adjustments Approach Eastbound Westbound Northbound Southbound Lane L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 Configuration L R LT TR Flow Rate, v (veh/h)263 84 299 324 Percent Heavy Vehicles 2 2 2 2 Initial Departure Headway, hd (s)3.20 3.20 3.20 3.20 Initial Degree of Utilization, x 0.234 0.075 0.265 0.288 Final Departure Headway, hd (s)6.66 5.44 5.65 4.93 Final Degree of Utilization, x 0.487 0.127 0.469 0.443 Move-Up Time, m (s)2.3 2.3 2.0 2.0 Service Time, ts (s)4.36 3.14 3.65 2.93 Capacity, Delay and Level of Service Approach Eastbound Westbound Northbound Southbound Lane L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 Configuration L R LT TR Flow Rate, v (veh/h)263 84 299 324 Capacity (veh/h)541 661 637 730 95% Queue Length, Q₉₅ (veh)2.6 0.4 2.5 2.3 Control Delay (s/veh)15.5 8.9 13.5 11.8 Level of Service, LOS C A B B Approach Delay (s/veh) | LOS 13.9 B 13.5 B 11.8 B Intersection Delay (s/veh) | LOS 13.1 B Copyright © 2023 University of Florida. All Rights Reserved.HCS™AWSC Version 2023 Generated: 11/8/2023 1:17:23 PMPV Lennard AM future.xaw Page 292 of 428 HCS All-Way Stop Control Report General and Site Information Lanes Analyst #23-081 Agency/Co.PTC Date Performed 11/6/2023 Analysis Year 2026 Analysis Time Period (hrs)0.25 Time Analyzed PM Peak Hour Project Description Walton Ranch; Future Intersection Prima Vista & Lennard Rd Jurisdiction SLC East/West Street Prima Vista Pkwy North/South Street Lennard Rd Ext. Peak Hour Factor 0.81 Turning Movement Demand Volumes Approach Eastbound Westbound Northbound Southbound Movement L T R L T R L T R L T R Volume (veh/h)92 203 117 11 22 100 % Thrus in Shared Lane Lane Flow Rate and Adjustments Approach Eastbound Westbound Northbound Southbound Lane L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 Configuration L R LT TR Flow Rate, v (veh/h)114 251 158 151 Percent Heavy Vehicles 2 2 2 2 Initial Departure Headway, hd (s)3.20 3.20 3.20 3.20 Initial Degree of Utilization, x 0.101 0.223 0.140 0.134 Final Departure Headway, hd (s)5.80 4.60 5.15 4.51 Final Degree of Utilization, x 0.183 0.320 0.226 0.189 Move-Up Time, m (s)2.3 2.3 2.0 2.0 Service Time, ts (s)3.50 2.30 3.15 2.51 Capacity, Delay and Level of Service Approach Eastbound Westbound Northbound Southbound Lane L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 Configuration L R LT TR Flow Rate, v (veh/h)114 251 158 151 Capacity (veh/h)620 783 698 798 95% Queue Length, Q₉₅ (veh)0.7 1.4 0.9 0.7 Control Delay (s/veh)9.8 9.4 9.7 8.6 Level of Service, LOS A A A A Approach Delay (s/veh) | LOS 9.6 A 9.7 A 8.6 A Intersection Delay (s/veh) | LOS 9.4 A Copyright © 2023 University of Florida. All Rights Reserved.HCS™AWSC Version 2023 Generated: 11/8/2023 11:48:15 AMPV Lennard PM future.xaw Page 293 of 428 HCS All-Way Stop Control Report General and Site Information Lanes Analyst #23-081 Agency/Co.PTC Date Performed 3/21/24 Analysis Year 2026 Analysis Time Period (hrs)0.25 Time Analyzed AM Peak Hour Project Description Walton Ranch; Buildout Intersection Prima Vista & Lennard Rd Jurisdiction SLC East/West Street Prima Vista Pkwy North/South Street Lennard Rd Ext. Peak Hour Factor 0.68 Turning Movement Demand Volumes Approach Eastbound Westbound Northbound Southbound Movement L T R L T R L T R L T R Volume (veh/h)179 76 240 37 24 204 % Thrus in Shared Lane Lane Flow Rate and Adjustments Approach Eastbound Westbound Northbound Southbound Lane L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 Configuration L R LT TR Flow Rate, v (veh/h)263 112 407 335 Percent Heavy Vehicles 2 2 2 2 Initial Departure Headway, hd (s)3.20 3.20 3.20 3.20 Initial Degree of Utilization, x 0.234 0.099 0.362 0.298 Final Departure Headway, hd (s)7.03 5.82 5.79 5.26 Final Degree of Utilization, x 0.514 0.181 0.656 0.490 Move-Up Time, m (s)2.3 2.3 2.0 2.0 Service Time, ts (s)4.73 3.52 3.79 3.26 Capacity, Delay and Level of Service Approach Eastbound Westbound Northbound Southbound Lane L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 Configuration L R LT TR Flow Rate, v (veh/h)263 112 407 335 Capacity (veh/h)512 619 621 685 95% Queue Length, Q₉₅ (veh)2.9 0.7 4.8 2.7 Control Delay (s/veh)16.9 9.8 19.1 13.2 Level of Service, LOS C A C B Approach Delay (s/veh) | LOS 14.8 B 19.1 C 13.2 B Intersection Delay (s/veh) | LOS 15.9 C Copyright © 2024 University of Florida. All Rights Reserved.HCS™AWSC Version 2023 Generated: 3/21/2024 12:18:31 PMPV Lennard AM buildout.xaw Page 294 of 428 HCS All-Way Stop Control Report General and Site Information Lanes Analyst #23-081 Agency/Co.PTC Date Performed 3/21/24 Analysis Year 2026 Analysis Time Period (hrs)0.25 Time Analyzed PM Peak Hour Project Description Walton Ranch; Buildout Intersection Prima Vista & Lennard Rd Jurisdiction SLC East/West Street Prima Vista Pkwy North/South Street Lennard Rd Ext. Peak Hour Factor 0.81 Turning Movement Demand Volumes Approach Eastbound Westbound Northbound Southbound Movement L T R L T R L T R L T R Volume (veh/h)92 264 153 25 46 100 % Thrus in Shared Lane Lane Flow Rate and Adjustments Approach Eastbound Westbound Northbound Southbound Lane L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 Configuration L R LT TR Flow Rate, v (veh/h)114 326 220 180 Percent Heavy Vehicles 2 2 2 2 Initial Departure Headway, hd (s)3.20 3.20 3.20 3.20 Initial Degree of Utilization, x 0.101 0.290 0.195 0.160 Final Departure Headway, hd (s)6.08 4.87 5.40 4.91 Final Degree of Utilization, x 0.192 0.441 0.330 0.246 Move-Up Time, m (s)2.3 2.3 2.0 2.0 Service Time, ts (s)3.78 2.57 3.40 2.91 Capacity, Delay and Level of Service Approach Eastbound Westbound Northbound Southbound Lane L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 Configuration L R LT TR Flow Rate, v (veh/h)114 326 220 180 Capacity (veh/h)592 739 666 734 95% Queue Length, Q₉₅ (veh)0.7 2.3 1.4 1.0 Control Delay (s/veh)10.2 11.4 11.0 9.5 Level of Service, LOS B B B A Approach Delay (s/veh) | LOS 11.1 B 11.0 B 9.5 A Intersection Delay (s/veh) | LOS 10.7 B Copyright © 2024 University of Florida. All Rights Reserved.HCS™AWSC Version 2023 Generated: 3/21/2024 12:24:57 PMPV Lennard PM buildout.xaw Page 295 of 428 Intersections 23-081 3-19-24 Historic Growth Rate =2.00% Nominal Growth Rate =1.00% Peak Season =1.17 Buildout Year = 2026 Years =3 Northbound Southbound Eastbound Westbound LT Thru RT LT Thru RT LT Thru RT LT Thru RT Existing Volume (10/26/23)14 1 1 0 0 10 9 8 6 0 31 0 Peak Season Volume 16 1 1 0 0 12 11 9 7 0 36 0 SUM Historic Growth 1 0 0 0 0 1 1 1 0 0 2 0 6 Nominal Growth 0 0 0 0 0 0 0 0 0 0 1 0 Approved Projects*45 0 0 0 0 0 0 28 13 0 106 0 Highest Inters. Growth 45 0 0 0 0 0 0 28 13 0 107 0 Background Traffic 61 1 1 0 0 12 11 37 20 0 143 0 % Project Traffic 0% 2% 0% 0% 2% 98% 98% 0% 0% 0% 0% 0% Direction in in in out out out in in in in in in Project Traffic 0 1 0 0 2 74 26 0 0 0 0 0 Total 61 2 1 0 2 85 37 37 20 0 143 0 Northbound Southbound Eastbound Westbound LT Thru RT LT Thru RT LT Thru RT LT Thru RT Existing Volume (10/26/23)10 1 15 8 30 4 0 1 8 2 15 0 Peak Season Volume 12 1 18 9 35 5 0 1 9 2 18 0 SUM Historic Growth 1 0 1 1 2 0 0 0 1 0 1 0 7 Nominal Growth 0 0 1 0 1 0 0 0 0 0 1 0 Approved Projects*26 0 0 0 0 0 0 110 48 0 60 0 Highest Inters. Growth 26 0 1 0 1 0 0 110 48 0 61 0 Background Traffic 38 1 19 9 36 5 0 111 57 2 79 0 % Project Traffic 0% 2% 0% 0% 2% 98% 98% 0% 0% 0% 0% 0% Direction in in in out out out in in in in in in Project Traffic 0 2 0 0 1 50 84 0 0 0 0 0 Total 38 3 19 9 37 55 84 111 57 2 79 0 * Prima Vista Commons and Silver Oaks 3/19/2024 14:56 193 PM Peak Hour Intersection Volume Development 247 INTERSECTION ANALYSIS SHEET Walton Ranch Tilton Rd & Silver Oaks Dr (Existing Geometrics w/Project) AM Peak Hour Intersection Volume Development Page 296 of 428 HCS All-Way Stop Control Report General and Site Information Lanes Analyst #23-081 Agency/Co.PTC Date Performed 3/21/24 Analysis Year 2023 Analysis Time Period (hrs)0.25 Time Analyzed AM Peak Project Description Walton Ranch, Background Intersection Tilton Rd & Silver Oaks Dr Jurisdiction SLC East/West Street Tilton Rd North/South Street Silver Oaks Dr Peak Hour Factor 0.80 Turning Movement Demand Volumes Approach Eastbound Westbound Northbound Southbound Movement L T R L T R L T R L T R Volume (veh/h)11 9 7 0 36 0 16 1 1 0 0 12 % Thrus in Shared Lane Lane Flow Rate and Adjustments Approach Eastbound Westbound Northbound Southbound Lane L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 Configuration LTR LTR LTR LTR Flow Rate, v (veh/h)34 45 23 15 Percent Heavy Vehicles 2 2 2 2 Initial Departure Headway, hd (s)3.20 3.20 3.20 3.20 Initial Degree of Utilization, x 0.030 0.040 0.020 0.013 Final Departure Headway, hd (s)3.98 4.04 4.26 3.52 Final Degree of Utilization, x 0.037 0.051 0.027 0.015 Move-Up Time, m (s)2.0 2.0 2.0 2.0 Service Time, ts (s)1.98 2.04 2.26 1.52 Capacity, Delay and Level of Service Approach Eastbound Westbound Northbound Southbound Lane L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 Configuration LTR LTR LTR LTR Flow Rate, v (veh/h)34 45 23 15 Capacity (veh/h)904 890 845 1022 95% Queue Length, Q₉₅ (veh)0.1 0.2 0.1 0.0 Control Delay (s/veh)7.1 7.3 7.4 6.6 Level of Service, LOS A A A A Approach Delay (s/veh) | LOS 7.1 A 7.3 A 7.4 A 6.6 A Intersection Delay (s/veh) | LOS 7.2 A Copyright © 2024 University of Florida. All Rights Reserved.HCS™AWSC Version 2023 Generated: 3/21/2024 12:39:06 PMTilton SO AM exist.xaw Page 297 of 428 HCS All-Way Stop Control Report General and Site Information Lanes Analyst #23-081 Agency/Co.PTC Date Performed 3/21/24 Analysis Year 2023 Analysis Time Period (hrs)0.25 Time Analyzed PM Peak Project Description Walton Ranch, Existing Intersection Tilton Rd & Silver Oaks Dr Jurisdiction SLC East/West Street Tilton Rd North/South Street Silver Oaks Dr Peak Hour Factor 0.71 Turning Movement Demand Volumes Approach Eastbound Westbound Northbound Southbound Movement L T R L T R L T R L T R Volume (veh/h)0 1 9 2 18 0 12 1 18 9 35 5 % Thrus in Shared Lane Lane Flow Rate and Adjustments Approach Eastbound Westbound Northbound Southbound Lane L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 Configuration LTR LTR LTR LTR Flow Rate, v (veh/h)14 28 44 69 Percent Heavy Vehicles 2 2 2 2 Initial Departure Headway, hd (s)3.20 3.20 3.20 3.20 Initial Degree of Utilization, x 0.013 0.025 0.039 0.061 Final Departure Headway, hd (s)3.66 4.20 3.82 4.04 Final Degree of Utilization, x 0.014 0.033 0.046 0.077 Move-Up Time, m (s)2.0 2.0 2.0 2.0 Service Time, ts (s)1.66 2.20 1.82 2.04 Capacity, Delay and Level of Service Approach Eastbound Westbound Northbound Southbound Lane L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 Configuration LTR LTR LTR LTR Flow Rate, v (veh/h)14 28 44 69 Capacity (veh/h)984 857 943 891 95% Queue Length, Q₉₅ (veh)0.0 0.1 0.1 0.3 Control Delay (s/veh)6.7 7.3 7.0 7.4 Level of Service, LOS A A A A Approach Delay (s/veh) | LOS 6.7 A 7.3 A 7.0 A 7.4 A Intersection Delay (s/veh) | LOS 7.2 A Copyright © 2024 University of Florida. All Rights Reserved.HCS™AWSC Version 2023 Generated: 3/21/2024 12:47:45 PMTilton SO PM exist.xaw Page 298 of 428 HCS All-Way Stop Control Report General and Site Information Lanes Analyst #23-081 Agency/Co.PTC Date Performed 11/3/2023 Analysis Year 2026 Analysis Time Period (hrs)0.25 Time Analyzed AM Peak Project Description Walton Ranch, Background Intersection Tilton Rd & Silver Oaks Dr Jurisdiction SLC East/West Street Tilton Rd North/South Street Silver Oaks Dr Peak Hour Factor 0.80 Turning Movement Demand Volumes Approach Eastbound Westbound Northbound Southbound Movement L T R L T R L T R L T R Volume (veh/h)11 37 20 0 143 0 61 1 1 0 0 12 % Thrus in Shared Lane Lane Flow Rate and Adjustments Approach Eastbound Westbound Northbound Southbound Lane L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 Configuration LTR LTR LTR LTR Flow Rate, v (veh/h)85 179 79 15 Percent Heavy Vehicles 2 2 2 2 Initial Departure Headway, hd (s)3.20 3.20 3.20 3.20 Initial Degree of Utilization, x 0.076 0.159 0.070 0.013 Final Departure Headway, hd (s)4.20 4.25 4.71 4.01 Final Degree of Utilization, x 0.099 0.211 0.103 0.017 Move-Up Time, m (s)2.0 2.0 2.0 2.0 Service Time, ts (s)2.20 2.25 2.71 2.01 Capacity, Delay and Level of Service Approach Eastbound Westbound Northbound Southbound Lane L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 Configuration LTR LTR LTR LTR Flow Rate, v (veh/h)85 179 79 15 Capacity (veh/h)857 847 764 898 95% Queue Length, Q₉₅ (veh)0.3 0.8 0.3 0.1 Control Delay (s/veh)7.7 8.4 8.3 7.1 Level of Service, LOS A A A A Approach Delay (s/veh) | LOS 7.7 A 8.4 A 8.3 A 7.1 A Intersection Delay (s/veh) | LOS 8.1 A Copyright © 2023 University of Florida. All Rights Reserved.HCS™AWSC Version 2023 Generated: 11/8/2023 10:58:10 AMTilton SO AM background.xaw Page 299 of 428 HCS All-Way Stop Control Report General and Site Information Lanes Analyst #23-081 Agency/Co.PTC Date Performed 11/3/2023 Analysis Year 2026 Analysis Time Period (hrs)0.25 Time Analyzed PM Peak Project Description Walton Ranch, Background Intersection Tilton Rd & Silver Oaks Dr Jurisdiction SLC East/West Street Tilton Rd North/South Street Silver Oaks Dr Peak Hour Factor 0.71 Turning Movement Demand Volumes Approach Eastbound Westbound Northbound Southbound Movement L T R L T R L T R L T R Volume (veh/h)0 111 57 2 79 0 38 1 19 9 36 5 % Thrus in Shared Lane Lane Flow Rate and Adjustments Approach Eastbound Westbound Northbound Southbound Lane L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 Configuration LTR LTR LTR LTR Flow Rate, v (veh/h)237 114 82 70 Percent Heavy Vehicles 2 2 2 2 Initial Departure Headway, hd (s)3.20 3.20 3.20 3.20 Initial Degree of Utilization, x 0.210 0.101 0.073 0.063 Final Departure Headway, hd (s)4.25 4.58 4.76 4.81 Final Degree of Utilization, x 0.279 0.145 0.108 0.094 Move-Up Time, m (s)2.0 2.0 2.0 2.0 Service Time, ts (s)2.25 2.58 2.76 2.81 Capacity, Delay and Level of Service Approach Eastbound Westbound Northbound Southbound Lane L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 Configuration LTR LTR LTR LTR Flow Rate, v (veh/h)237 114 82 70 Capacity (veh/h)848 786 757 748 95% Queue Length, Q₉₅ (veh)1.1 0.5 0.4 0.3 Control Delay (s/veh)8.9 8.4 8.3 8.3 Level of Service, LOS A A A A Approach Delay (s/veh) | LOS 8.9 A 8.4 A 8.3 A 8.3 A Intersection Delay (s/veh) | LOS 8.6 A Copyright © 2023 University of Florida. All Rights Reserved.HCS™AWSC Version 2023 Generated: 11/8/2023 11:42:40 AMTilton SO PM background.xaw Page 300 of 428 HCS All-Way Stop Control Report General and Site Information Lanes Analyst #23-081 Agency/Co.PTC Date Performed 3/21/24 Analysis Year 2026 Analysis Time Period (hrs)0.25 Time Analyzed AM Peak Project Description Walton Ranch, Buildout Intersection Tilton Rd & Silver Oaks Dr Jurisdiction SLC East/West Street Tilton Rd North/South Street Silver Oaks Dr Peak Hour Factor 0.80 Turning Movement Demand Volumes Approach Eastbound Westbound Northbound Southbound Movement L T R L T R L T R L T R Volume (veh/h)37 37 20 0 143 0 61 2 1 0 2 85 % Thrus in Shared Lane Lane Flow Rate and Adjustments Approach Eastbound Westbound Northbound Southbound Lane L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 Configuration LTR LTR LTR LTR Flow Rate, v (veh/h)118 179 80 109 Percent Heavy Vehicles 2 2 2 2 Initial Departure Headway, hd (s)3.20 3.20 3.20 3.20 Initial Degree of Utilization, x 0.104 0.159 0.071 0.097 Final Departure Headway, hd (s)4.54 4.52 4.94 4.15 Final Degree of Utilization, x 0.148 0.224 0.110 0.125 Move-Up Time, m (s)2.0 2.0 2.0 2.0 Service Time, ts (s)2.54 2.52 2.94 2.15 Capacity, Delay and Level of Service Approach Eastbound Westbound Northbound Southbound Lane L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 Configuration LTR LTR LTR LTR Flow Rate, v (veh/h)118 179 80 109 Capacity (veh/h)793 797 729 867 95% Queue Length, Q₉₅ (veh)0.5 0.9 0.4 0.4 Control Delay (s/veh)8.3 8.8 8.5 7.7 Level of Service, LOS A A A A Approach Delay (s/veh) | LOS 8.3 A 8.8 A 8.5 A 7.7 A Intersection Delay (s/veh) | LOS 8.4 A Copyright © 2024 University of Florida. All Rights Reserved.HCS™AWSC Version 2023 Generated: 3/21/2024 12:44:33 PMTilton SO AM buildout.xaw Page 301 of 428 HCS All-Way Stop Control Report General and Site Information Lanes Analyst #23-081 Agency/Co.PTC Date Performed 3/21/24 Analysis Year 2026 Analysis Time Period (hrs)0.25 Time Analyzed PM Peak Project Description Walton Ranch, Buildout Intersection Tilton Rd & Silver Oaks Dr Jurisdiction SLC East/West Street Tilton Rd North/South Street Silver Oaks Dr Peak Hour Factor 0.71 Turning Movement Demand Volumes Approach Eastbound Westbound Northbound Southbound Movement L T R L T R L T R L T R Volume (veh/h)84 111 57 2 79 0 38 3 19 9 37 55 % Thrus in Shared Lane Lane Flow Rate and Adjustments Approach Eastbound Westbound Northbound Southbound Lane L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 Configuration LTR LTR LTR LTR Flow Rate, v (veh/h)355 114 85 142 Percent Heavy Vehicles 2 2 2 2 Initial Departure Headway, hd (s)3.20 3.20 3.20 3.20 Initial Degree of Utilization, x 0.315 0.101 0.075 0.126 Final Departure Headway, hd (s)4.61 4.97 5.22 4.89 Final Degree of Utilization, x 0.454 0.158 0.122 0.193 Move-Up Time, m (s)2.0 2.0 2.0 2.0 Service Time, ts (s)2.61 2.97 3.22 2.89 Capacity, Delay and Level of Service Approach Eastbound Westbound Northbound Southbound Lane L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 Configuration LTR LTR LTR LTR Flow Rate, v (veh/h)355 114 85 142 Capacity (veh/h)782 724 690 736 95% Queue Length, Q₉₅ (veh)2.4 0.6 0.4 0.7 Control Delay (s/veh)11.4 8.9 8.9 9.1 Level of Service, LOS B A A A Approach Delay (s/veh) | LOS 11.4 B 8.9 A 8.9 A 9.1 A Intersection Delay (s/veh) | LOS 10.2 B Copyright © 2024 University of Florida. All Rights Reserved.HCS™AWSC Version 2023 Generated: 3/21/2024 12:52:15 PMTilton SO PM buildout.xaw Page 302 of 428 Intersections 23-081 3-19-24 Historic Growth Rate =2.00% Nominal Growth Rate =1.00% Peak Season =1.17 Buildout Year = 2026 Years =3 Northbound Southbound Eastbound Westbound LT Thru RT LT Thru RT LT Thru RT LT Thru RT Existing Volume (10/26/23)14 1 1 0 0 10 9 8 6 0 31 0 Peak Season Volume 16 1 1 0 0 12 11 9 7 0 36 0 SUM Historic Growth 1 0 0 0 0 1 1 1 0 0 2 0 6 Nominal Growth 0 0 0 0 0 0 0 0 0 0 1 0 Approved Projects*45 0 0 0 0 0 0 28 13 0 106 0 Highest Inters. Growth 45 0 0 0 0 0 0 28 13 0 107 0 Background Traffic 61 1 1 0 0 12 11 37 20 0 143 0 % Project Traffic 0% 2% 0% 0% 2% 98% 98% 0% 0% 0% 0% 0% Direction in in in out out out in in in in in in Project Traffic 0 1 0 0 2 74 26 0 0 0 0 0 Total 61 2 1 0 2 85 37 37 20 0 143 0 Northbound Southbound Eastbound Westbound LT Thru RT LT Thru RT LT Thru RT LT Thru RT Existing Volume (10/26/23)10 1 15 8 30 4 0 1 8 2 15 0 Peak Season Volume 12 1 18 9 35 5 0 1 9 2 18 0 SUM Historic Growth 1 0 1 1 2 0 0 0 1 0 1 0 7 Nominal Growth 0 0 1 0 1 0 0 0 0 0 1 0 Approved Projects*26 0 0 0 0 0 0 110 48 0 60 0 Highest Inters. Growth 26 0 1 0 1 0 0 110 48 0 61 0 Background Traffic 38 1 19 9 36 5 0 111 57 2 79 0 % Project Traffic 0% 2% 0% 0% 2% 98% 98% 0% 0% 0% 0% 0% Direction in in in out out out in in in in in in Project Traffic 0 2 0 0 1 50 84 0 0 0 0 0 Total 38 3 19 9 37 55 84 111 57 2 79 0 * Prima Vista Commons and Silver Oaks 3/21/2024 12:57 75 (51) NB Approach Volume:39 (87) LT % AM:69% LT % PM:99% Left Turn Lane Determination Worksheet Walton Ranch Tilton Rd & Silver Oaks Dr (Existing Geometrics w/Project) AM Peak Hour Intersection Volume Development 193 PM Peak Hour Intersection Volume Development 247 Si l v e r O a k s D r 12 ( 5 0 ) 27 ( 8 6 ) Driveway 12 ( 1 ) Page 303 of 428 HCS Two-Way Stop-Control Report General Information Site Information Analyst #23-081 Intersection Silver Oaks Dr & Site Driveway Agency/Co.PTC Jurisdiction SLC Date Performed 3/21/2024 East/West Street Site Driveway Analysis Year 2026 North/South Street Silver Oaks Dr Time Analyzed AM Peak Peak Hour Factor 0.92 Intersection Orientation North-South Analysis Time Period (hrs)0.25 Project Description Walton Ranch; Buildout Lanes Major Street: North-South Vehicle Volumes and Adjustments Approach Eastbound Westbound Northbound Southbound Movement U L T R U L T R U L T R U L T R Priority 10 11 12 7 8 9 1U 1 2 3 4U 4 5 6 Number of Lanes 0 1 0 0 0 0 0 0 1 0 0 0 1 0 Configuration LR LT TR Volume (veh/h)0 75 27 12 12 0 Percent Heavy Vehicles (%)2 2 2 Proportion Time Blocked Percent Grade (%)0 Right Turn Channelized Median Type | Storage Undivided Critical and Follow-up Headways Base Critical Headway (sec)7.1 6.2 4.1 Critical Headway (sec)6.42 6.22 4.12 Base Follow-Up Headway (sec)3.5 3.3 2.2 Follow-Up Headway (sec)3.52 3.32 2.22 Delay, Queue Length, and Level of Service Flow Rate, v (veh/h)82 29 Capacity, c (veh/h)1067 1605 v/c Ratio 0.08 0.02 95% Queue Length, Q₉₅ (veh)0.2 0.1 Control Delay (s/veh)8.7 7.3 0.1 Level of Service (LOS)A A A Approach Delay (s/veh)8.7 5.1 Approach LOS A A Copyright © 2024 University of Florida. All Rights Reserved.HCS™TWSC Version 2023 Generated: 3/21/2024 1:03:30 PMSilver Drive AM.xtw Page 304 of 428 HCS Two-Way Stop-Control Report General Information Site Information Analyst #23-081 Intersection Silver Oaks Dr & Site Driveway Agency/Co.PTC Jurisdiction SLC Date Performed 3/21/2024 East/West Street Site Driveway Analysis Year 2026 North/South Street Silver Oaks Dr Time Analyzed PM Peak Peak Hour Factor 0.92 Intersection Orientation North-South Analysis Time Period (hrs)0.25 Project Description Walton Ranch; Buildout Lanes Major Street: North-South Vehicle Volumes and Adjustments Approach Eastbound Westbound Northbound Southbound Movement U L T R U L T R U L T R U L T R Priority 10 11 12 7 8 9 1U 1 2 3 4U 4 5 6 Number of Lanes 0 1 0 0 0 0 0 0 1 0 0 0 1 0 Configuration LR LT TR Volume (veh/h)0 51 86 1 50 0 Percent Heavy Vehicles (%)2 2 2 Proportion Time Blocked Percent Grade (%)0 Right Turn Channelized Median Type | Storage Undivided Critical and Follow-up Headways Base Critical Headway (sec)7.1 6.2 4.1 Critical Headway (sec)6.42 6.22 4.12 Base Follow-Up Headway (sec)3.5 3.3 2.2 Follow-Up Headway (sec)3.52 3.32 2.22 Delay, Queue Length, and Level of Service Flow Rate, v (veh/h)55 93 Capacity, c (veh/h)1013 1551 v/c Ratio 0.05 0.06 95% Queue Length, Q₉₅ (veh)0.2 0.2 Control Delay (s/veh)8.8 7.5 0.5 Level of Service (LOS)A A A Approach Delay (s/veh)8.8 7.4 Approach LOS A A Copyright © 2024 University of Florida. All Rights Reserved.HCS™TWSC Version 2023 Generated: 3/21/2024 1:11:28 PMSilver Drive PM.xtw Page 305 of 428 kimley-horn.com 200 South Orange Avenue, Suite 600, Orlando, Florida 32801 407 898 1511 To:Irene Szedlmayer, AICP Senior Planner St. Lucie County Planning & Development Services From: Alex Memering, P.E. Alex Campano, E.I. Kimley-Horn and Associates, Inc. Kimley-Horn and Associates, Inc. Date: May 9, 2024 Re:Walton Ranch Final Review of Traffic Analysis Kimley-Horn has reviewed the traffic impact analysis (revised December 15, 2023) prepared by Pinder Troutman Consulting, Inc. related to the above-mentioned project. The proposed development consists of 151 single-family detached dwelling units. The project is generally located northwest of the Silver Oaks Drive at Tilton Road intersection in St. Lucie County. The total trip generation potential for the proposed development is 1,474 daily, 108 AM peak hour (28 entering / 80 exiting), and 146 PM peak hour (92 entering / 54 exiting) net new trips. Access to the site is proposed via one full access connection on Silver Oaks Drive. The study area roadway segments and intersections were evaluated and found to operate acceptably, with the exception of the Prima Vista Boulevard at US 1 intersection. Prima Vista Boulevard at US 1 was found to require several background improvements prior to the addition of project traffic. Based on the expected project traffic at the intersection no additional improvements are expected to be required to accommodate the addition of project traffic. Thank you for the opportunity to assist St. Lucie County in reviewing this project. Please contact us if you have any questions or need additional information. Page 306 of 428 LOTS 16, BLOCK 3, PLAT NO. 1, ST. LUCIE GARDENS BY THE INDIAN RIVER (PLAT BOOK 1, PAGE 35) LOTS 1, BLOCK 2 (PLAT BOOK 1, PAGE 35)LOTS 3, BLOCK 2 (PLAT BOOK 1, PAGE 35) LO T S 4 , B L O C K 2 ( P L A T B O O K 1 , P A G E 3 5 ) LOTS 14, BLOCK 3, PLAT NO. 1, ST. LUCIE GARDENS BY THE INDIAN RIVER (PLAT BOOK 1, PAGE 35)LOTS 13, BLOCK 3, PLAT NO. 1, ST. LUCIE GARDENS BY THE INDIAN RIVER (PLAT BOOK 1, PAGE 35) FL FL FL FL FL FL FL F L FL FL F L FL F L F L FL F L FL FL FL FL FL FL FL FL FL FL F L F L F L F L F L F L F L F L F L F L F L F L F L F L F L F L F L F L F L F L F L F L F L F L FL FL F L F L FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL F L FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL SITE LO T S 1 , 2 , 1 5 A N D 1 6 B L O C K 2 , S E C T I O N 2 3 , T O W N S H I P 3 6 S O U T H , RA N G E 4 0 E A S T , P L A T N O . 1 , S T . L U C I E G A R D E N S B Y T H E I N D I A N RI V E R , A S R E C O R D E D I N T H A T C E R T A I N P L A T R E C O R D E D I N P L A T BO O K 1 , P A G E 3 5 O F T H E P U B L I C R E C O R D S O F S T . L U C I E CO U N T Y , F L O R I D A ; L E S S R D . T H A T P A R T L Y I N G I N R I G H T O F W A Y IF A N Y . A L T A / N S P S L A N D T I T L E S U R V E Y LA N D S C A P E A R C H I T E C T U R E - S U R V E Y I N G CA U L F I E L D & W H E E L E R , I N C . CI V I L E N G I N E E R I N G - L A N D P L A N N I N G PH O N E ( 5 6 1 ) - 3 9 2 - 1 9 9 1 / F A X ( 5 6 1 ) - 7 5 0 - 1 4 5 2 79 0 0 G L A D E S R O A D - S U I T E 1 0 0 BO C A R A T O N , F L O R I D A 3 3 4 3 3 Page 307 of 428 LOTS 2, BLOCK 2 (PLAT BOOK 1, PAGE 35) LOTS 3, BLOCK 2 (PLAT BOOK 1, PAGE 35) LOTS 2, BLOCK 2 (PLAT BOOK 1, PAGE 35) LOTS 4, BLOCK 2, (PLAT BOOK 1, PAGE 35) LOTS 14, BLOCK 2 (PLAT BOOK 1, PAGE 35) LOTS 13, BLOCK 2 (PLAT BOOK 1, PAGE 35) X X X X X X X X X X X X X X X FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL F L F L FL FL FL FL FL FL FL FL FL F L FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL F L FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL F L F L F L FL FL FL LOTS 15, BLOCK 2 (PLAT BOOK 1, PAGE 35) LOTS 14, BLOCK 2 (PLAT BOOK 1, PAGE 35) X LOTS 2, BLOCK 2 (PLAT BOOK 1, PAGE 35) LOTS 3, BLOCK 2 (PLAT BOOK 1, PAGE 35) EXTREMELY OVERGROWN WITH BUILDING THAT ARE IN DISREPAIR (18.069 ACRES MORE OR LESS) WETLAND 4 (WETLAND LIMITS AS APPROVED BY SFWMD MARCH 2024) 1.327 ACRES MORE OR LESS LA N D S C A P E A R C H I T E C T U R E - S U R V E Y I N G CA U L F I E L D & W H E E L E R , I N C . CI V I L E N G I N E E R I N G - L A N D P L A N N I N G PH O N E ( 5 6 1 ) - 3 9 2 - 1 9 9 1 / F A X ( 5 6 1 ) - 7 5 0 - 1 4 5 2 79 0 0 G L A D E S R O A D - S U I T E 1 0 0 BO C A R A T O N , F L O R I D A 3 3 4 3 3 LO T S 1 , 2 , 1 5 A N D 1 6 B L O C K 2 , S E C T I O N 2 3 , T O W N S H I P 3 6 S O U T H , RA N G E 4 0 E A S T , P L A T N O . 1 , S T . L U C I E G A R D E N S B Y T H E I N D I A N RI V E R , A S R E C O R D E D I N T H A T C E R T A I N P L A T R E C O R D E D I N P L A T BO O K 1 , P A G E 3 5 O F T H E P U B L I C R E C O R D S O F S T . L U C I E CO U N T Y , F L O R I D A ; L E S S R D . T H A T P A R T L Y I N G I N R I G H T O F W A Y IF A N Y . A L T A / N S P S L A N D T I T L E S U R V E Y Page 308 of 428 LOTS 16, BLOCK 2 (PLAT BOOK 1, PAGE 35) LOTS 14, BLOCK 2 (PLAT BOOK 1, PAGE 35) LOTS 14, BLOCK 2 (PLAT BOOK 1, PAGE 35) X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X EXTREMELY OVERGROWN WITH BUILDING THAT ARE IN DISREPAIR (18.069 ACRES MORE OR LESS) LA N D S C A P E A R C H I T E C T U R E - S U R V E Y I N G CA U L F I E L D & W H E E L E R , I N C . CI V I L E N G I N E E R I N G - L A N D P L A N N I N G PH O N E ( 5 6 1 ) - 3 9 2 - 1 9 9 1 / F A X ( 5 6 1 ) - 7 5 0 - 1 4 5 2 79 0 0 G L A D E S R O A D - S U I T E 1 0 0 BO C A R A T O N , F L O R I D A 3 3 4 3 3 LO T S 1 , 2 , 1 5 A N D 1 6 B L O C K 2 , S E C T I O N 2 3 , T O W N S H I P 3 6 S O U T H , RA N G E 4 0 E A S T , P L A T N O . 1 , S T . L U C I E G A R D E N S B Y T H E I N D I A N RI V E R , A S R E C O R D E D I N T H A T C E R T A I N P L A T R E C O R D E D I N P L A T BO O K 1 , P A G E 3 5 O F T H E P U B L I C R E C O R D S O F S T . L U C I E CO U N T Y , F L O R I D A ; L E S S R D . T H A T P A R T L Y I N G I N R I G H T O F W A Y IF A N Y . A L T A / N S P S L A N D T I T L E S U R V E Y Page 309 of 428 Date Mailed: July 5, 2024 Planning and Development Services Department (772) 462-2822 Property Owners: Viva Communities at Silver Oaks 1, LLC 365 Route 59 Ste. 110 Airmont, NY 10952 and Silver Oak Drive, LLC 2359 SW Danforth Circle Palm City, FL 34990 Applicant: Meritage Homes 1395 University Blvd. Suite 300 Jupiter, FL 33458 Agent of Record: Cotleur & Hearing 1934 Commerce Lane Jupiter, FL 33407 Project Location: Northwest of the intersection of Silver Oak Drive and Tilton Road Project File Number: RZ-2312-000029 Existing Zoning Districts: AR-1 (Agricultural, Residential- 1 dwelling unit per acre) & RM-5 (Residential, Multiple-family- 5 dwelling units per acre) Proposed Zoning District: PUD (Planned Unit Development) Existing Future Land Use: RU (Residential Urban) Parcel IDs: 3414-501-0615-000-2 and 3414–501-0602-000-8 PLANNING AND ZONING COMMISSION Meeting Time: 6:00 PM (or soon thereafter) Location: BOCC Chambers SLC Administration Annex 2300 Virginia Ave. Fort Pierce, FL 34982 Project Description This application is a request to: 1. re-zone +/- 46 acres from the AR-1 & RM-5 Zoning Districts to the PUD (Planned Unit Development) Zoning District; and, 2. obtain approval of a Prelimi- nary Development Plan for 141 single-family houses with +/- 42% common open space in- cluding a 2.64-acre restored wetland, landscaping buffers, stormwater, walking paths and other improvements. Upcoming Public Hearing: The Planning & Zoning Commis-sion has the power to review and recommend approval or disap- proval to the Board of County Commissioners, of applications for re-zoning and Preliminary De- velopment Plans. The Planning & Zoning Commis- sion strongly encourages your input and comment at the public hearing. You may also mail or email written comments regarding this application in advance of the public hearing for inclusion in the official record. Anyone with a disability requiring accommodations to attend this meeting may contact the SLC Community Risk Manager at least 48 hours in advance at (772) 462- 1546 or TDD (772) 462-1428. Please see reverse side for a small reproduction of the Prelimi- nary Development Plan. (Continued on Reverse) Notice of Public Hearing Proposed Zoning Amendment & Preliminary Site Plan Thursday, July 18, 2024 You are receiving this notice because you own property within 500-ft. of the subject site. Subject Site Le n n a r d R d . Tilton Rd. Si l v e r O a k D r . Page 310 of 428 Walton Ranch Preliminary Development For more information, please contact: Staff: Irene Szedlmayer Senior Planner Telephone: (772) 462-1562 Email: Szedlmayeri@stlucieco.org Mail: Planning & Development Services Department 2300 Virginia Ave. Fort Pierce, FL 34982 Page 311 of 428 Page 312 of 428 Page 313 of 428 Page 314 of 428 Planning and Development Services Department Planning Division M E M O R A N D U M SUGGESTED MOTIONS: MOTION TO APPROVE AFTER CONSIDERING THE TESTIMONY PRESENTED DURING THE PUBLIC HEARING, INCLUDING STAFF COMMENTS, AND THE STANDARDS OF REVIEW AS SET FORTH IN SECTION 11.07.03, ST. LUCIE COUNTY LAND DEVELOPMENT CODE, I HEREBY MOVE THAT THE PLANNING AND ZONING COMMISSION RECOMMEND THAT THE ST. LUCIE COUNTY BOARD OF COUNTY COMMISSIONERS APPROVE THE CHANGE IN ZONING FROM RM-5 AND AR-1 TO PUD AND THE PRELIMINARY DEVELOPMENT PLAN FOR THE WALTON RANCH RESIDENTIAL DEVELOPMENT, SUBJECT TO THE CONDITIONS IDENTIFIED IN THE DRAFT RESOLUTION, BECAUSE ... [CITE REASONS WHY - PLEASE BE SPECIFIC] MOTION TO DENY AFTER CONSIDERING THE TESTIMONY PRESENTED DURING THE PUBLIC HEARING, INCLUDING STAFF COMMENTS, AND THE STANDARDS OF REVIEW AS SET FORTH IN SECTION 11.07.03, ST. LUCIE COUNTY LAND DEVELOPMENT CODE, I HEREBY MOVE THAT THE PLANNING AND ZONING COMMISSION RECOMMEND THAT THE ST. LUCIE COUNTY BOARD OF COUNTY COMMISSIONERS DENY THE CHANGE IN ZONING FROM RM-5 AND AR-1 TO PUD AND THE PRELIMINARY DEVELOPMENT PLAN FOR THE WALTON RANCH RESIDENTIAL DEVELOPMENT, BECAUSE ... .[CITE REASONS WHY - PLEASE BE SPECIFIC] Page 315 of 428 ITEM NO. (ID # 2024-34384) DATE: 7/18/2024 AGENDA REQUEST TO: Planning and Zoning Commission PRESENTED BY: Irene Szedlmayer, Senior Planner SUBMITTED BY: Planning & Development Services SUBJECT: O'Reilly's Auto Parts petition for a Conditional Use Permit to develop a retail auto parts store in the CN (Commercial Neighborhood) Zoning District BACKGROUND: O'Reilly Automotive Stores, Inc. proposes to construct a 7,472 sq. ft. auto parts store with associated site improvements including parking, landscaping, and onsite storm water detention in the CN (Commercial Neighborhood) Zoning District. The subject property is a 1.33-acre parcel at the corner of Turnpike Feeder Road and Palomar Parkway. PREVIOUS ACTION: The Land Development Code was amended in 2022 to allow auto parts stores not exceeding 10,000 sq. ft. to locate in the CN Zoning District, pursuant to a Conditional Use permit. On June 26, 2024, the Board of Adjustment (Special Magistrate) granted a variance for the subject project, to reduce the minimum intersection setback distances for the eastern driveway - with left turn movements. FINANCIAL IMPACT: No immediate short-term impact, but a developed commercial parcel will generate more in property taxes than an undeveloped parcel. RECOMMENDATION: Staff recommends the Planning & Zoning Commission forward a recommendation of approval, with Conditions, to the Board of County Commissioners. COMMISSION ACTION: RESULT: MOVER: None SECONDER: None AYES: None NAYS: None EXCUSED: None Page 316 of 428 Coordination/Signatures Date: July 12, 2024 Benjamin Balcer, Planning & Development Services Director Date: July 12, 2024 Katherine Barbieri, Assistant County Attorney III Date: July 12, 2024 Mayte Santamaria, Deputy County Administrator Page 317 of 428 Planning and Development Services Department Planning Division M E M O R A N D U M TO:Planning and Zoning Commission THROUGH:Benjamin Balcer, AICP, Planning and Development Services Director Kori Benton, AICP, Planning Manager FROM:Irene Szedlmayer, Senior Planner DATE:July 9, 2024 SUBJECT: AGENDA ITEM: Petition of O’Reilly Automotive Stores, Inc. for a Conditional Use Permit to develop a 7,472 sq. ft. auto parts store in the CN (Commercial Neighborhood) Zoning District 9.D. GENERAL INFORMATION: Property Owner: Wrightland, Inc. 114 Queen Elizabeth Ct. Hutchinson Island, FL 34949 Applicant: O’Reilly Automotive, Inc. 233 South Patterson Avenue Springfield, MO 65802 Agents: Craig A. Schneider, AIA Esterly Schneider & Associates, Inc. 1736 E. Sunshine, Suite 417 Springfield, MO 65804 OWN, Inc. 35008 Emerald Coast Parkway Suite 204 Destin, FL 32541 Location:5028 Turnpike Feeder Road, Fort Pierce, FL 34946 Parcel ID Numbers: 1301-615-0210-000-0 and 1301-615-0209-000-0 Parcel Size: +/-1.32 acres; 57,499 sq. ft. Future Land Use:RU (residential Urban) Zoning District:CN (Commercial Neighborhood) Purpose:A Conditional Use Permit for the retail sale of auto parts in the CN (Commercial, neighborhood) Zoning District Existing Use:Undeveloped, wooded lot Proposed Use:Retail sales of auto parts File No:CU-2402-000069 Page 318 of 428 O’Reilly Auto Parts File No.: CU 2402-000069 Page 2 Figure 1. Location Map with aerial imagery BACKGROUND O'Reilly Automotive Stores, Inc. proposes to construct a 7,472 sq. ft. auto parts store with associated site improvements including parking, landscaping, and onsite storm water detention in the CN (Commercial Neighborhood) Zoning District. As illustrated in Figure 1, the subject property is a 1.33-acre corner parcel with frontage on four streets--Turnpike Feeder Road, Palomar Parkway, DeLeon Avenue, and Abaca Drive. LDC Sec. 3.01.03.Q.7.d.(3) requires a Conditional Use Permit (CUP) in the CN (Commercial Neighborhood) for “Auto/home supply stores, not to exceed ten thousand (10,000) square feet in floor area, offering retail sale of new automobile batteries, parts, and accessories, excluding tire dealers, with the hours of operation limited from 7:00 a.m. to 8:00 p.m.” The ability to locate an auto parts store in the CN Zoning District pursuant to a Conditional Use Permit (CUP) was made possible by an amendment to the Land Development Code Subject Site Indrio Road Turn p i k e Feed e r Rd. Palomar Pkwy. Road Miromar Avenue Page 319 of 428 O’Reilly Auto Parts File No.: CU 2402-000069 Page 3 approved in 2022. The amendment added these uses as to the CN Zoning District pursuant to a CUP: “(3) Auto/home supply stores, not to exceed ten thousand (10,000) square feet in floor area, offering retail sale of new automobile batteries, parts, and accessories, excluding tire dealers, with the hours of operation limited from 7:00 a.m. to 8:00 p.m. (5531) (4) Hardware stores between six thousand one (6,001) and ten thousand (10,000) square feet in floor area with hours of operation limited from 7:00 a.m. to 8:00 p.m. (5251) (5) Household appliance stores dealing in primarily new appliances between six thousand one (6,001) and ten thousand (10,000) square feet with the hours of operations limited from 7:00 a.m. to 8:00 p.m. (5722)” The applicant that brought that amendment forward is the owner of the subject property. It has owned the subject lots since 1999 and 2001. This proposed use at the subject location in the CN Zoning District also requires approval of a Minor Site Plan and a Variance, in addition to the Conditional Use Permit. The variance was approved on June 26, 2024, by the Board of Adjustment to permit left turn movements at a driveway with more than 50 daily trips that is less than 350 ft. from the base building line of the adjacent intersections. O’Reilly’s Automotive, Inc. driveway onto Palomar Parkway is +/- 135 ft. from the Turnpike Feeder Road base building line and +/- 50 ft. from the DeLeon Ave. base building line. *********************************************************************************** STANDARDS FOR CONDITIONAL USE REVIEW AS SET FORTH IN SECTION 11.07.03 OF THE ST. LUCIE COUNTY LAND DEVELOPMENT CODE As provided in the Land Development Code (LDC) Section 2.00.00, a conditional use is a “use that is generally compatible with the use characteristics of a zoning district, but that requires individual review of its location, design, potential effect on nearby properties, and configuration in accordance with Section 11.07.00 to determine the appropriateness of the use on any particular site in the district.” LDC Section 11.07.03. establishes the Standards for Review for Conditional Use Permits and provides that approval shall be granted only if the applicant demonstrates that is satisfies criteria regarding (A) Consistency with the Local Code and Comprehensive Plan, (B) the Effect on Adjacent properties, (C) the Adequacy of Public Facilities, (D) Adequacy of Fire Protection, and (E) Environmental Impact. These five criteria are considered below. A. Consistency with Land Development Code and Comprehensive Plan The Development Review Committee reviewed the Conditional Use Permit application and found it to be consistent with the general purpose, goals, objectives, and standards of the LDC and Comprehensive Plan. Page 320 of 428 O’Reilly Auto Parts File No.: CU 2402-000069 Page 4 Land Development Code The basic development standards for the CN Zoning District are provided in Table 1. The subject property (+/- 57,499 sq. ft. in area and +/- 179.9 ft. in width) and the proposed auto parts retail store comply with them. Table 1. Excerpt from LDC Section 7.04.01. Table 7-10 Lot Size and Dimensional Requirements Minimum YardZoning District Min. Lot Size Min. Lot Width Min. Front- age Front Rear Side Side Corner Max. Bldg. Height Max. Lot Cover. CN 10,000 sq. ft.75 ft.60 ft.25 ft.20 ft.10 ft.20 ft.35 ft.50% Figure 2. Zoning Districts of Surrounding Land Area O’Reilly’s proposed Minor Site Plan, which is contingent upon the subject Conditional Use, has not yet received final Development Review Committee (DRC) certification, but it is required to adhere to all applicable standards and only a few minor “clean-up” type revisions remain. The proposed site plan has demonstrated compliance with the applicable parking, stormwater and community architectural standards. Only minor changes are required to the landscape plan. The access onto Turnpike Feeder Road is required to comply with FDOT requirements. Subject Site Turn p i k e F e e d e r R o a d Page 321 of 428 O’Reilly Auto Parts File No.: CU 2402-000069 Page 5 Figure 3. Proposed Site Plan Comprehensive Plan The proposed Conditional Use is consistent with the goals, objectives, and standards of the St. Lucie County Comprehensive Plan. As provided in Comp. Plan Policy 1.1.1.2.E., Limited nonresidential uses may be appropriate, in accordance with applicable standards and restrictions as set forth in the Land Development Code. Pursuant to Comprehensive Plan Policy 1.1.1.3., the CN (Commercial Neighborhood) Zoning District is consistent with the RU (Residential Urban) Future Land Use Designation. The proposed Retail Store is consistent with at least these three Comprehensive Plan Goals: Page 322 of 428 O’Reilly Auto Parts File No.: CU 2402-000069 Page 6 Policy 1.1.9.4 - Limited development of commercial/non-residential uses, that are not located within a special area plan adopted within the Towns, Villages and Countryside Element, will be allowed within areas classified for residential use, provided that these activities are compatible with the adjacent land uses and meet the following standards: a) Intent of the commercial use is to provide easily accessible, convenience-type uses to immediately surrounding residents; c) Use is compatible with surrounding land uses and is provided with adequate screening and buffering of any adjacent residential property; Goal 10.1: Support economic development in St. Lucie County as part of an overall strategy for sustainability and quality of life. Goal 10.2: Diversify the year round economy and establish an economic and cultural climate that will allow St. Lucie County to effectively compete in the global economy. B. Effect on Nearby Properties Development of the subject parcel is likely to have a beneficial effect on the properties along the +/- 0.9-mile segment of Turnpike Feeder Road north of Indrio Road by demonstrating demand for commercial uses. The properties fronting Turnpike Feeder Road have CO (Commercial Office) or CN zoning. Additionally, the project is extending a sanitary sewer line approximately 900 feet north along Turnpike Feeder Road which has the potential to benefit other properties in the vicinity. To the east and south of the subject site is a +/- 44-acre residential neighborhood within the RM-5 zoning district. It is developed primarily with duplexes but also includes a scattering of small multi-family buildings. The neighborhood is somewhat isolated in that the street network does not currently connect it to any adjoining residential neighborhood and it is not yet served by public water or public wastewater facilities. Figure 4. Nearby Residential Neighborhood Subject Site Page 323 of 428 O’Reilly Auto Parts File No.: CU 2402-000069 Page 7 LDC Section 11.07.03.B., Effect on Nearby Properties, requires in more detail, the following: 1. The proposed conditional use will not have an undue adverse effect upon nearby property. 2. The proposed conditional use is compatible with the existing or planned character of the neighborhood in which it would be located. 3. All reasonable steps have been taken to minimize any adverse effect of the proposed conditional use on the immediate vicinity through building design, site design, landscaping, and screening. 4. The proposed conditional use will be constructed, arranged, and operated so as not to interfere with the development and use of neighboring property, in accordance with applicable district regulations. The proposed O’Reilly’s Auto Parts Store meets these standards. The proposed use should not have an undue adverse effect upon surrounding properties based upon the buffering provided by the landscape plan, the limits on hours of operation required by the LDC, and access to the site on and off Trunpike Feeder Road. It is true that development of this site will require the removal of numerous native trees and some residents of the neighborhood east of the subject site may miss the buffer created by the currently undeveloped lots on Turnpike Feeder Road. New detached single-family homes were recently constructed at 5012 and 5014 DeLeon Avenue. These properties will likely have increased exposure to activities of Turnpike Feeder Road through the loss of the existing tree cover on the undeveloped lot. The removal of the trees would occur pursuant to any proposed development and is not particular to this request for a CUP. Additionally, this risk is mitigated by the proposed location of the stormwater pond near Abaca Drive and the proposed naturalistic, but dense, planting of numerous trees including red maples, bald cypress, slash pine, live oak and laurel oak creating an attractive buffer in the vicinity of DeLeon Avenue and Abaca Drive. Finally, Staff believes the proposed auto parts retail store poses less risk of adverse impact on nearby properties than some other uses permitted by-right in the CN Zoning District. For example, fast food restaurants including drive-in windows are permitted in the CN Zoning District (SIC Code 5812). The potential adverse impacts from hours of operation, traffic and odors would appear to be greater for that use than the proposed auto parts retailer. C. Adequacy of Public Facilities Utilities: The project will be served by St. Lucie County public water and sanitary sewer lines. The project will extend a sanitary sewer line approximately 900 feet north along Turnpike Feeder Road. Other utilities such as electricity, cable, internet should be readily available. Traffic: The traffic generated is not anticipated to adversely impact the level of service for Turnpike Feeder Road. Page 324 of 428 O’Reilly Auto Parts File No.: CU 2402-000069 Page 8 According to the Applicant’s Traffic Impact Report, the proposed retail store is expected to generate 408 trips per day, but 43% of those are projected to be pass-by trips, that is, cars that are already on the roadway for other purposes, resulting in 233 net trips generated by the proposed use. Turnpike Feeder Road has a peak-hour capacity of 870 vehicles and the proposed project will add 11 trips in the AM peak hour and 21 in the PM peak hour. The driveway onto Turnpike Fedder Road will be limited to right-turns in and right-turns out. However, the intersection of Palomar Parkway and Turnpike Feeder Road allows all turning movements. ROW Adequacy: Turnpike Feeder Road as a 100-ft right-of-way and Palomar Parkway has a 70-ft right-of-way. The County has not requested right-of-way for this project. D. Adequacy of Fire Protection The St. Lucie County Fire District has reviewed the application as a contributor of the Development Review Committee (DRC). The applicant will be required to obtain Zoning Compliance approval for the use and is required to complete an inspection with the Fire District to assure compliance with the Florida Fire Prevention Code and the Florida Life Safety Code. The nearest Fire Station #7 is the nearest to the site. Located at 4900 Fort Pierce Blvd., Fort Pierce, it is less than one mile from the subject parcel. E. Environmental Impact As discussed previously, significant tree cover will be lost with the development of the site. While the developer is given mitigation credits for preserving some trees on site, the developer will be required to pay some $60,500 to mitigate the loss of trees on site. As indicated previously, the loss of trees would likely occur with any development of the site. The loss of trees is not particular to the request to develop an auto parts store, but possibly the extent of impacts correlating with the store’s size and parking demands. The Environmental Resources Department has no objection to the approval of the requested Conditional Use Permit. STAFF RECOMMENDATION: Staff has determined the Conditional Use Permit meets the standards identified in LDC Section 11.07.03., and is consistent with the Goals, Objectives, and Policies of the Comprehensive Plan. Therefore, staff recommends the Planning and Zoning Commission forward a recommendation of approval to the Board of County Commissioners. Page 325 of 428 Resolution No. 24-___ Page 1 File No. CU-2402-000069 RESOLUTION NO. 2024-___ File No.: CU-2402-000069 A RESOLUTION OF THE BOARD OF COUNTY COMMISSIONERS OF ST. LUCIE COUNTY FOR A CONDITIONAL USE PERMIT TO ALLOW A +/- 7,627 SQ. FT. AUTO PARTS RETAIL STORE IN THE CN (COMMERCIAL, NEIGHBORHOOD) ZONING DISTRICT AT 5028 TURNPIKE FEEDER ROAD., IN ST. LUCIE COUNTY, FLORIDA. WHEREAS, the Board of County Commissioners of St. Lucie County, Florida, based on the testimony and evidence, including but not limited to the staff report, has made the following determinations: 1. O’Reilly Automotive Stores, Inc. presented a petition for a Conditional Use Permit to allow the construction of a 7,472 sq. ft. auto supply store, including parking, stormwater, landscaping and other improvements, within the CN (Commercial, Neighborhood) Zoning District for the property located at 5028 Turnpike Feeder Road, Fort Pierce, FL, as legally described in Paragraph “C” and depicted on the attached map as Exhibit “A”. 2. On July 18, 2024, the St. Lucie County Planning and Zoning Commission held a public hearing on the petition, after publishing notice in the St. Lucie News Tribune at least 10 days prior to the hearing, installing a sign on the property, and notifying by mail all owners of property within five hundred (500) feet of the subject property, and recommended that the Board of County Commissioners approve/deny the request for a Conditional Use Permit. 3. On _____________, the Board of County Commissioners held a public hearing on the petition, after publishing notice in the St. Lucie News Tribune at least 10 days prior to the hearing, installing a sign on the property and notifying by mail all owners of property within 500 feet of the subject property, at which all interested persons were given an opportunity to be heard. 4. All reasonable steps have been taken to minimize any adverse effect of the proposed conditional use on the immediate vicinity through site design, architectural design and landscaping. 5. The proposed Conditional Use, will not have an undue adverse effect on adjacent property, the character of the neighborhood, traffic conditions, parking, utility facilities, or other matters affecting the public health, safety, and general welfare. 6. The proposed Conditional Use will be serviced by adequate public facilities and services. NOW, THEREFORE, BE IT RESOLVED by the Board of County Commissioners of St. Lucie County, Florida: Page 326 of 428 Resolution No. 24-___ Page 2 File No. CU-2402-000069 A. The foregoing findings are hearby approved and adopted by the Board of County Commissioners of St. Lucie County, FL. B. Pursuant to LDC Section 11.07.03. and Section 3.01.03.S.7., the Conditional Use Permit for O’Reilly’s Automotive Stores, Inc. as hereby depicted in the Conditional Use Plan prepared by Craig A. Schneider, AIA, is hereby approved/denied for the property described in Paragraph “C” below, subject to approval of the proposed Final Site Plan. C. The subject property is described as follows: Lots 14, 15 and 16, Block 178, Lakewood Park - Unit 12A, according to the plat thereof, as recorded in Plat Book 11, Page 35, of the Public Records of St. Lucie County, Florida, being a parcel of land located within the Northwest Quarter of Section 13, Township 34 South, Range 39 East, T.M., being more particularly described as follows: Beginning at a 1/2 inch rebar with yellow plastic cap marked “LS 7134” set for the most Westerly corner of said Lot 14; thence along the Northwesterly line of said Lots 14, 15 and 16, being also the Southeasterly right-of-way line of Turnpike Feeder Road, North 45°29'35” East 179.94 feet to a 3/8 inch rebar inside a one inch iron pipe found marking the most Northerly corner of said Lot 16, and a point on the Southwesterly right-of-way line of Palomar Parkway at a point on a 326.00 foot radius curve, concave Northeasterly; thence Southeasterly along said right-of-way line and the arc of said curve through a central angle of 44°07'19” and an arc length of 256.73 feet (Chord bearing South 67°13'17" East 250.15 feet); thence along said right-of-way line South 89°08'39” East 9.50 feet to a one inch iron pipe found and the Westerly right-of-way line of Deleon Avenue; thence along said line, South 00°15'19” West 31.32 feet to a one inch iron pipe found and the Northwesterly right-of-way line of Abaca Drive; thence along said right-of- way line and the Southeasterly line of said Lots 16, 15 and 14, South 45°29'03” West 261.04 feet to a 1/2 inch rebar with yellow plastic cap marked “LS 7134” set for the most Southerly corner of said Lot 14; thence along the Southwesterly line of said Lot 14, North 44°31'52” West 259.79 feet to the Point of Beginning; containing 56,407 Square Feet, or 1.295 Acres, more or less. PARCEL IDS: 1301-615-0210-000-0 and 1301-615-0209-000-0 D. The approvals and authorizations granted by this Resolution are for the purpose of obtaining a Minor Site Plan, Building Permit and Zoning Compliance from St. Lucie County, and are not assigned to any other party or institution. Should the petitioners choose or decide to assign this business to another entity or individual, a minor adjustment to the Conditional Use Permit shall be required. E. Pursuant to Section 11.07.05(I) of the St. Lucie County Land Development Code, approvals and authorizations granted by this Resolution shall expire after twelve (12) months from the date of approval, unless a Building Permit or Certificate of Zoning Compliance is obtained for the uses described in Paragraph “B” above, or an extension Page 327 of 428 Resolution No. 24-___ Page 3 File No. CU-2402-000069 has been granted in accordance with Section 11.07.05(F). F. The petitioner is advised as part of this Conditional Use Permit approval, the petitioner shall obtain all applicable site plan approval, development permits and construction authorizations from the appropriate state and federal and local regulatory agencies including, but not limited to, the United States Army Corps of Engineers, the Florida Department of Environmental Protection, and South Florida Water Management District, and the St. Lucie County Environmental Resources, Public Works and Building Departments prior to the commencement of any development activities on the property described in Paragraph “C”. Issuance of this permit by the County does not in any way create any rights on the part of the petitioner to obtain a permit from a state or federal agency and does not create any liability on the part of the County for issuance of this permit if the petitioner fails to obtain requisite approvals or fulfill the obligations imposed by a state or federal agency or undertake actions that may result in a violation of state or federal law. G. The St. Lucie County Planning and Development Services Director is hereby authorized and directed to cause the notation of this resolution to be made on the Official Zoning Map of St. Lucie County, Florida, and to make notation of reference to the date of adoption of this resolution. H. A copy of this Resolution shall be mailed to the owner and agent of record as identified on the application. A copy shall be attached to the Conditional Use Permit Site Plan drawings as described in Paragraph “B” and placed on file with the Planning and Development Services Department. I. This Resolution shall be recorded in the Public Records. After motion and second, the vote on this resolution was as follows: Cathy Townsend, Chair XXX Chris Dzadovsky, Vice-chair XXX Larry Leet, Commissioner XXX Linda Bartz, Commissioner XXX Jamie Fowler, Commissioner XXX PASSED AND DULY ADOPTED this _____ day of ___________2024. BOARD OF COUNTY COMMISSIONERS ST. LUCIE COUNTY, FLORIDA Page 328 of 428 Resolution No. 24-___ Page 4 File No. CU-2402-000069 BY _________________________ Chair ATTEST: APPROVED AS TO FORM AND CORRECTNESS: __________________________ _________________________ Deputy Clerk County Attorney Page 329 of 428 Resolution No. 24-___ Page 5 File No. CU-2402-000069 Exhibit “A” (Location Map) Page 330 of 428 Resolution No. 24-___ Page 6 File No. CU-2402-000069 Exhibit “B” (Site Plan) Page 331 of 428 Planning and Development Services Department Planning Division M E M O R A N D U M SUGGESTED MOTIONS: MOTION TO APPROVE AFTER CONSIDERING THE TESTIMONY PRESENTED DURING THE PUBLIC HEARING, INCLUDING STAFF COMMENTS, AND THE STANDARDS OF REVIEW AS SET FORTH IN SECTION 11.07.03, ST. LUCIE COUNTY LAND DEVELOPMENT CODE, I HEREBY MOVE THAT THE PLANNING AND ZONING COMMISSION RECOMMEND THAT THE ST. LUCIE COUNTY BOARD OF COUNTY COMMISSIONERS APPROVE THE CONDITIONAL USE PERMIT FOR THE O’REILLY’S AUTO PARTS STORE, SUBJECT TO THE CONDITIONS IDENTIFIED IN THE DRAFT RESOLUTION, BECAUSE ... [CITE REASONS WHY - PLEASE BE SPECIFIC] MOTION TO DENY AFTER CONSIDERING THE TESTIMONY PRESENTED DURING THE PUBLIC HEARING, INCLUDING STAFF COMMENTS, AND THE STANDARDS OF REVIEW AS SET FORTH IN SECTION 11.07.03, ST. LUCIE COUNTY LAND DEVELOPMENT CODE, I HEREBY MOVE THAT THE PLANNING AND ZONING COMMISSION RECOMMEND THAT THE ST. LUCIE COUNTY BOARD OF COUNTY COMMISSIONERS DENY THE CONDITIONAL USE PERMIT FOR THE O’REILLY’S AUTO PARTS STORE, BECAUSE ... .[CITE REASONS WHY - PLEASE BE SPECIFIC] Page 332 of 428 + 2 3 . 6 P V T + 2 3 . 6 P V T + 22 . 7 P V T + 2 3 . 7 P V T + 2 3 . 6 P V T + 23.5 GD 21 23 22 23 22 22 2 3 2 2 2 1 21 22 21 2 3 22 2322 21 21 21 20 21 22 20 24 21 22 23 23 22 21 22 2 3 23 2 3 22222222222 GRA D E B R E A K GR A D E B R E A K 22 2 3 23 21 21 21 21 21 21 PROPOSED DETENTIONPOND 20.5 19.5 + 19.5 GD 19.5 20.5 23 23 23 23 2 3 . 9 S W 2 3 . 9 P V T 2 3 . 9 S W 2 3 . 9 P V T 2 3 . 8 S W 2 3 . 8 P V T 23 . 8 S W 2 3 . 3 P V T 23.0 T C 22.5 P V T 2 3 . 9 T C 2 3 . 4 P V T 23 . 8 T C 23 . 3 P V T 23.8 T C 23.3 P V T 23.5 T C 23.0 P V T 22.8 PVT 22.5 S W 22.5 P V T 23.7 TC 23.2 PVT 23.6 TC 23.1 PVT 23.3 TC 22.8 PVT 23.6 TC 23.1 PVT23.7 T C 23.2 P V T 23.8 T C 23.3 P V T 23.6 T C 23.1 P V T 23.5 TC 23.0 PVT 22.9 S W 22.9 P V T 24 . 0 T C 2 3 . 5 P V T 22.6 S W 22.6 P V T 2 3 . 6 T C 2 3 . 1 P V T 23.7 P V T 23.0 S W 23.0 P V T 2 3 . 8 T C 2 3 . 3 P V T 24 . 1 T C 23 . 6 P V T 24 . 0 T C 23 . 5 P V T 20.9 EPVT 23.5 T C 23.0 P V T 2 3 . 5 G D 22.5 P V T 2 3 . 5 S W 23 . 5 S W 23.5 S W 2 2 . 0 S W 2 1 . 0 E X S W 2 0 . 9 E X S W 23.0 S W 22.9 S W 19.9 S W 20.0 S W 22.0 S W 21.9 S W 2 1 . 9 S W 1 8 . 7 G D 2 3 . 8 S W 2 4 . 2 T C 23 . 7 P V T 23.9 TC 23.4 PVT 2 3 . 7 S W 22.6 TC 22.1 PVT 20.8 E P V T 22.6 S W 22.6 S W 22.6 SW 22.6 PVT 23.8 T C 23.3 P V T 23.6 T C 23.1 P V T 23.8 T C 23.3 P V T 2 4 . 1 T C 2 3 . 6 P V T 2 4 . 0 T C 2 3 . 5 P V T 22.5 SW 22.5 PVT 22.5 SW 22.5 PVT 21.3 SW 21.4 SW 21.3 SW 21.3 SW 21.3 SW 21.2 SW 21.1 SW 21.2 SW 21.2 SW 21.2 SW 22.0 SW 22.1 SW 21. 5 S W 21. 6 S W 20.2 EXSW 2 0 . 1 E X S W 23.6 S W 23.3 S W 23.2 S W GR A D E B R E A K 22.1 P V T 23. 8 P V T + 19.5 GD 20.0 20.0 2 3 . 5 S W 2 3 . 6 S W 2 3 . 4 S W 2 3 . 5 S W 2 3 . 5 S W 2 3 . 5 P V T 2 3 . 4 S W 2 3 . 4 P V T 24. 1 T C 23. 6 P V T 24. 4 T C 23. 9 P V T 23. 8 T C 23. 3 P V T 24.3 T C 23.8 P V T 22. 7 S W 22. 6 S W 555 2222 P 5 TTTTT SWSSW 22 9 W2222222 55 55 PP SWSW TTTTTT 2222 999 WW TTTTTTTTTTTPPPP55555555SWSWSWSW5555 22222222 999 WWWWW 2 2 SWSWSWSWSWSWSWSWSW 222SWSWSWSWSWSWSWSWSWSWSWSWSWSWSW22222 22 SWSWSW22 2. PPP SSWW 29 WW 222222222222 ...SS WW PVPPPPPPP 2929222222222 PVPPVPVP 2.2... WW 29292929 WWWW 2222 2 WWSW92 22 WWWW T 1 S VVVV 5 PPPPPPP 555 P 22 55 WWSW9S222 2 W VT 2222 S PVPV 5555 5 2 22222 22222 12 22 . TVTPPP5SW5S52222222222 22 22 VTPV 22WPP2. 95 WWWWS 222 22 2 33 2 3 2 3 222 GG 5 G 5 G 8 3 8 3 8 222 DD G D G D SS 33 7 3 7 WW W S W S W WWW +++ 33 2222222222222222222222922222922229292999999999S999SSSWSWSWSWSSSSSWSWSSWSWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWSWSWSWSWSWSWWSWWSWWWWSWSSWSWSSSSSSSS9S9SSSSSSSSSS9S99999999999999999S99999999999992929299929299222222222222222222222222222222222222222222222222222222222222 + WWWWWW S W SS W S W S W SS W 5 S 5 S 555 3 5 2 3 3 2 3 222 ++ WWWWWWWWWWWWWW S W WWWWWW S W S W S W WW S W W S W S W SS W S W SSSSSSS 5 S S 5 S 5555 S 555555 33 5 5 3 5 333333 2 3 2 3 2 3 22222 3 2 3 222 W S W W2121 222222 3 S CCC 2 4 TTTT P V PP 2222 5 P 9 PV 2 3 2 3 2 3 4 S W SS W 3 T C 333 2222 P V 8 P V T VVVVVV P V 3 VV AA 333 K P 36 TTTT 555 33 TT P 33 333 3 VTVT 333 VTVTVTVT TVTTVTVTV TT 33 PP P 2 4 CC 33 SWS 2222 2 4 2 4 3 2 3 33 2 3 2 3 .3 P V P V V T VVV 2 333 CCC CC V T VV T P V P 44 SS W SS W S W 22 00 TTTTTT PVP TTTTT P TTTTT 33 222222 22222 88 VVVVV KKKKKKK VV 99 P V P V AAAAAAAAA 333 3636 333 222TT PVP 333 55 TT 33 33333 TT PVP VTVT VTTVTTTTT 2 4 2 4 3733 VTVT P V PP V CCCC PVP V P V PPP V 999 CCCCC 2222 P V T P V V T PPVPVPV 5 P 5 P P 2 4 2 4 4 SWSWSW P V P V P V 2222222 TTT 444 PP SSS 22 37337 3733 2 3 2 3 33 PVPV VTVTVTVT PVPPV 88 222 TTTTT 3.33. TTTTTTTTT P V PP V VTVTVT 333 TTT 55P5P555 PVPV AAAAA VVV 33 2 4 2 4 2 4 PPP 666 KKK 000 P V T P V V T 33 333 22 SWSW 0 2 CCC 323233 VV 22222 44 S W 222 P 3.3 VTVT 3333 V T V 2222 TT TTT 222 7 55 P PV 25 4 2323 666 VVV V PPV 55 3 VV 22 CC WSWSW 323232323 0P 3. 9 3 VTVT 232232222 4 P 4 VV V 44 222 PVVV 555 VVVVVV 525555 2 22222 PP 55 7P7P PPVPPV 33 33 0P00P 33 TT 333333333 4 P 4 4 P PP CC 2323223 7P77P 22 S W S W 5555 VTVVTVTVT 23222 222 222222222 9.99 V T V T V TTTTTT 23233 2552525555 PVPVVPV PPPPPPP 444 66 333 55 VVV GR PV 4 2222 CC P 3 C 5555 VV 0 SSSS 22 8 P 23 SSSS 8 3232 P V PP WW 23 VTVTV 66 S 3 8 3 8 222 7P 2 TT GGGG DE AKAKAKAAAAAA 33 VT 23232 CC 3 VT 23232323 C 3.3.3. 8 VT 3 38 2323 4 VT V T P 2222 PP P V P V 7P7P 22 TTT 2 3 2 3 33 PVPV 333 VTVT VV T AKAA PP 44 EDEEEDE CC 3232323 GRGR 222 2222 22222 55555 SSSSSSSSS VTVTVTVTVTVVTVT 3 8 3 8 VTV CC 22 PVP SS 2323 00 88 WW SSSSSSS 88 232323232323 2 8..8....VTVT V T V T CC 2323 3838 TVTVT 000 22222 GRRGR PPP PVPV 333 8888 PVTPVPV CCC CCC 2332323 555 SSSSSSSSSSS PP 222 VVV 23232 3233333 SSS VTVTTVTVTVTTTVTVTVTVT 8 8 88888 222 666 P V P V V PPPP 22222222 GGGGGGGGG TT 2323232323232323 .3 EEEEEE 222 PPP 33 CC TTT AKAKAKAK TTTT 38388 22 232323232 VTVTVT 83.8333388 CCC VTVTTT 888 33 2222323 VTVTVT V T V T V T 444 PP 2 6S 6P T T R DE 2 BR AK 4 3 C 333 T P 2 V T 3 V 3 3 5 P P V T 6 V T 2 P 3. V V 6 C + 888 V WW WW 333 P S 9 S 3 3 V T 3 4 P VPV 223 W C 3 222 S 9 T 8 V W 2 3 222222 3 S W 3 5 5 S 2 3 2 T 3333 V T EAEA RA T T T 2 TT 2 VT 2 7 + 1 2 3 6 T T 4 2 3 P V 5 23 PVTC BB D R P T 33 23 T PVPV 23 8 C 2 222 63 22 44 V 2 T VT 8 222 3T V 8 3 1 T C T 2 55 3 2 3 3 T P V 2 2 T 3 9 T C P 2 P 92 KEA BRBR ADADRG WS V 22 23 62 VT 92 TP 223 CC T 4 P V T 6 T6 VT PV VP 2 2 3 VTPV 2 . 2 3 PVPVPVPV T 2 WP V 3 PV 4 WW 2 T7 5555 S W TTT C VVV T 2 3 5 P T 23 V 33 P 3 623 3 3 RARA G AAAAA VV C C 88 T S W W C 2 6 8 23 3 2 3 S 2 C V 222 RT V PV PV V T3 888 1 6 4 T 9 3 3 2 23 24 3 VTPV 23 62 VT 3 3T 24 TP3 TC8T V VV2 2 P1 V T T C V T P32 P 8883 2 3 2 VT P V . G T6 CCC P V 3 TT 16 S 222 313 GG S W 2 3 VP P P T D T 3.2 . 2BR RE V 23 AE 3 TC 38C P23 4 999 WW T C T3 2 2 T 6 V 3 3 2PV 3 3 P 2 S W P V 2 T V T T 8 8 5 4 0 23 6 24 2 P 33 V T K 24 23 1222 T VTP 33 2 243 TS 2 3 0 999 VT33 2 C PPP 3P3222C WP TCP32DE P RCC3 3 KKK T T T V 222 +3 7777 T C P T3 T3 777 VVV V T G 3 RA VT T T C 4 T C3 3 3V T V T 3 35 2 PV6 WPVVWW3 2 V T RA22 TTT3. 8 TEP2 2 4EEE 322CC62 222 T87 T 5 P C9 DDD4 V T S03 6PPP22 SC 2 KV2 V2 8P4 8 2CCCPPPP PV 299 ..3.23.2 WWSWSW 99S9 WSWW 3 2S W 21 99 333 SSS WWW 212121 99999999999999999999999992122121 WWWW2S2SS2SS3333323 S SWSWSW SS 232323232323 SSSS SWSWWSW 33333 S WWWW 2222 9919 S 33333 SS WWWW 22 999999 S 333333 WWWWWWWSSSS SSSS19199222222222222 WWWWWWWSSSS2S323232322 W9S99999999911222 WWWWWSS2332222 WSWS9S9S9999999212 WWS2S2323 WS 122 WWWWSSSWSSSS2333333333333333332 WSWS.922221212 2222 2 1.1. 1.22 20.0 3 2 3 3 2 222 3333 5 T P CCCT 2. 22 9PP9 VT 2 3 2 3 2 3 VVTV 2122121 121 1 22 212 33 2 TC TTT 2 3 2 3 2 3 222222222222222222222 WW 211 11111 22232222 CCCCCCCCC P V P V P V V T V T VV T P V C T C 22.9 S W S99922 WWWWWWWWSWS9S9999922222222 + RRREAEAEAEAEAA 2020 202 W 22.9 S W SWWWWWWWSS992222 W 22.9 S W SWW9999WW 22 WWWWWWWWSWS9S9999922222222 22 22222 ..6 S W ..6 S W .6 S W .6 S W 1 8 1 8 1 8 1 8 VT 20.50 9.19 20.50 ++ 19.595 2 DD ++ + 19.59 +++++++++ 222222222222222282888 8 PPVPVPVVVVVVVVVVVV 23.5 TC 23.0 PVT 22 21 1 C1.1 SITE GRADING PLAN SCALE: 1"= 20' STAGES OF CONSTRUCTION: 1. CONTRACTOR TO PERFORM DETAILED SITE INSPECTION TO LOCATE ALL EXISTING UTILITES AND VERIFY ANY POSSIBLE CONFLICTS WITH PROPOSED IMPROVEMENTS PRIOR TO BEGINNING ANY CONSTRUCTION. CONTACT OWNER WITH ANY CONFLICTS. MONTH 1 2. INSTALLATION OF CONSTRUCTION ENTRANCE. MONTH 1 3. INSTALLATION OF EROSION CONTROL FENCE. MONTH 1 4. DEMOLITION OF EXISTING SITE IMPROVEMENTS. MONTH 1 5. REMOVAL OF EXISTING PAVEMENT ON THE SITE. MONTH 1 6. INSTALLATION OF ALL STORM WATER DRAINAGE IMPROVEMENTS. MONTH 1 7. ROUGH GRADING. MONTH 1 & MONTH 2 8. CONSTRUCTION OF NEW SITE IMPROVEMENTS. MONTH 2 9. FINAL GRADING. MONTH 3 10. PLACEMENT OF FINAL LANDSCAPING ITEMS AND SOD. MONTH 3 11. REMOVAL OF EROSION CONTROL FENCE. MONTH 3 1. A GEOTECHNICAL ANALYSIS HAS BEEN PERFORMED ON THIS SITE. REFER TO PROJECT MANUAL. 2. WORK SHALL BE DONE IN ACCORDANCE WITH THE GEOTECHNICAL REPORT BY ATLAS TECHNICAL CONSULTANTS, LLC DATED MAY 31, 2023. REFER TO STRUCTURAL DRAWINGS FOR BUILDING EXCAVATION REQUIREMENTS. SITE EXCAVATION REQUIREMENTS: GENERAL NOTES: PIPES NOTES: 20 + 19 . 0 P V T KEY NOTES: STORMWATER RUNOFF SUMMARY: TOTAL PROPERTY AREA= 1.29 ACRES, TOTAL DISTURBED AREA = 1.40 ACRES > 1.0 ACRES: THEREFORE NOI IS REQUIRED. REFER TO STORMWATER COMPUTATIONS BY OWN, INC. C1.1 PR O J E C T : NE W O ' R E I L L Y A U T O P A R T S S T O R E TU R N P I K E F E E D E R R D FO R T P I E R C E , F L # 4 SI T E G R A D I N G P L A N CO R P O R A T E O F F I C E S 23 3 S O U T H P A T T E R S O N SP R I N G F I E L D , M I S S O U R I 6 5 8 0 2 (4 1 7 ) 8 6 2 - 2 6 7 4 T E L E P H O N E REVISION DATE: DATE: COMM #4712 BKR BDO22SP10143 SCALE: 1" = 10' HANDICAP PARKING DETAIL C1.12 HANDICAP PARKING DETAIL. REFER TO DETAIL 2/C1.1 INSTALL 4' X 4' AREA INLET. RIM = 22.8' INV = 20.3' SUMP = 19.3' REFER TO DETAIL 1/C1.2. INSTALL 4' X 4' AREA INLET. RIM = 22.7' INV = 20.0' SUMP = 19.0' REFER TO DETAIL 1/C1.2. INSTALL 119 LF OF 15" Ø PIPE. INV IN = 20.3' INV OUT = 20.0' REFER TO PIPE NOTES. INSTALL 64 LF OF 15" Ø PIPE. INV IN = 20.0' INV OUT = 19.8' REFER TO PIPE NOTES. INSTALL 4' X 4' AREA INLET. RIM = 22.5' INV = 19.8' SUMP = 18.8' REFER TO DETAIL 1/C1.2. INSTALL 86 LF OF 15" Ø PIPE. INSTALL MES AT END OF PIPE. INV IN = 19.8' INV OUT = 19.5'. REFER TO PIPE NOTES. DRY DETENTION POND. TOP OF POND ELEVATION = 20.5' BOTTOM BASIN ELEVATION = 19.5'. REFER TO DETAIL 2/C1.2. INSTALL 197 L.F. 15" PIPE. FL IN = 18.9. FL OUT = 18.7. REFER TO PIPE NOTES. INSTALL MES AT END PER STANDARD PLANS FOR ROAD CONSTRUCTION INDEX 430-022. CROSS SLOPE OF SIDEWALK SHALL NOT EXCEED 2%. INSTALL CURB RAMP PER FDOT INDEX NO. 522-002, SIDEWALK CURB RAMP CR-F. INSTALL DRIVEWAY PER DOT REQUIREMENTS. SEE FDOT NOTES ON THIS SHEET. REFER TO FDOT STANDARD PLANS FOR ROAD CONSTRUCTION INDEX 330-001 & FLORIDA DESIGN MANUAL. 1. GOVERNING DOCUMENTS NOTE: ALL WORK IN THE RIGHT-OF-WAY SHALL BE DONE IN ACCORDANCE WITH THE 2023/2024 STANDARD PLAN FOR ROADWAY CONSTRUCTION, THE 2023/2024 STANDARD SPECIFICATIONS FOR ROAD & BRIDGE CONSTRUCTION, 2023 FLORIDA DESIGN MANUAL, 2018 FLORIDA GREENBOOK, 2017 PLANS PREPARATION MANUAL (PPM), AND THE 2009 MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD). 2. HURRICANE NOTE: ALL LANES MUST BE OPENED TO TRAFFIC WITHIN 12 HOURS AFTER RECEIVING NOTIFICATION OF A HURRICANE EVACUATION OR ANY OTHER CATASTROPHIC EVENT AND SHALL REMAIN OPEN FOR THE DURATION OF THE EVACUATION OR EVENT AS DIRECTED BY THE PERMITS MANAGER. 3. PRE-CONSTRUCTION NOTE: ENGINEER MUST SCHEDULE AND HAVE AN ON-SITE PRE-CONSTRUCTION MEETING (WITH REPRESENTATIVES FROM THE ENGINEERING FIRM, FDOT, TESTING LABORATORY, CONTRACTOR, AND ANY OTHER INTERESTED PARTY PRESENT). 4. QC PLAN NOTE (FOR TURN LANES AND WIDENING PROJECTS ONLY): CONTRACTOR MUST SUBMIT A QUALITY CONTROL (QC) PLAN AT THE PRE-CONSTRUCTION MEETING. THIS QC PLAN MUST BE APPROVED BY FDOT BEFORE THE CONTRACTOR BEGINS WORK. TESTING MUST BE DONE BY A FDOT CERTIFIED LABORATORY. ALL TEST RESULTS WILL BE REQUIRED TO BE SUBMITTED WITH THE ENGINEER'S CERTIFICATION. 5. SOD NOTE: SOD AREAS WITHIN 32” OF PAVEMENT & SLOPES GREATER THAN 1:3. OTHER DISTURBED AREAS MAY BE REPAIRED BY SEEDING OR HYDRO-SEEDING. SEE STANDARD PLANS INDEX 570-010 AND SECTION 570 OF THE STANDARD SPECIFICATIONS FOR ROAD & BRIDGE CONSTRUCTION. 6. STRIPING NOTE: ALL STRIPING WITHIN FDOT RIGHT OF WAY SHALL BE THERMOPLASTIC AND ADHERE TO STANDARD PLANS INDEX 711-001 AND SECTION 711 OF THE STANDARD SPECIFICATIONS FOR ROAD & BRIDGE CONSTRUCTION. 7. LANE AND SHOULDER CLOSURES: ALL LANE AND SHOULDER CLOSURES MUST BE REQUESTED AND APPROVED A MINIMUM OF 48 HOURS PRIOR TO WORK STARTING. ALLOW UP TO 2 WEEKS FOR APPROVAL PROCESS. 8. DITCH FLOWLINE: IT IS THE CONTRACTOR'S RESPONSIBILITY TO PLACE SIDE DRAIN PIPES TO MATCH FLOWLINE OF DITCH (NOT SEDIMENT BUILDUP) TO INSURE POSITIVE STORMWATER FLOW. FDOT NOTES: 23.85 PVT 23.85 SW 23.6 PVT + 2 3 . 4 P V T 23.6 PVT 23.7 5 P V T + + 23 . 7 5 P V T 23.6 PVT 23.9 PVT 23.9 SW 23.85 SW23.85 PVT + 2 3 . 4 P V T 23.9 SW 23.9 PVT 24.0 FFE 06-16-2023 INSTALL DRIVEWAY INLCUDING MOUNTABLE AND STRIPED ISLAND PER DOT REQUIREMENTS. SEE DOT NOTES ON SHEET C1.2. INSTALL STOP SIGN (MUTCD SIGN R1-1) AND STOP BAR PER MUTCD REQUIREMENTS. STOP BAR SHALL BE 24" WIDE AND SOLID WHITE. 1. CONTRACTOR TO PERFORM DETAILED SITE INSPECTION TO LOCATE ALL EXISTING UTILITES AND VERIFY ANY POSSIBLE CONFLICTS WITH PROPOSED IMPROVEMENTS PRIOR TO BEGINNING ANY CONSTRUCTION. CONTACT OWNER WITH ANY CONFLICTS. MONTH 1 2. INSTALLATION OF CONSTRUCTION ENTRANCE. MONTH 1 3. INSTALLATION OF EROSION CONTROL FENCE. MONTH 1 4. DEMOLITION OF EXISTING SITE IMPROVEMENTS. MONTH 1 5. REMOVAL OF EXISTING PAVEMENT ON THE SITE. MONTH 1 6. INSTALLATION OF ALL STORM WATER DRAINAGE IMPROVEMENTS. MONTH 1 7. ROUGH GRADING. MONTH 1 & MONTH 2 8. CONSTRUCTION OF NEW SITE IMPROVEMENTS. MONTH 2 9. FINAL GRADING. MONTH 3 10. PLACEMENT OF FINAL LANDSCAPING ITEMS AND SOD. MONTH 3 11. REMOVAL OF EROSION CONTROL FENCE. MONTH 3 1. A GEOTECHNICAL ANALYSIS HAS BEEN PERFORMED ON THIS SITE. REFER TO PROJECT MANUAL. 2. WORK SHALL BE DONE IN ACCORDANCE WITH THE GEOTECHNICAL REPORT BY ATLAS TECHNICAL CONSULTANTS, LLC DATED MAY 31, 2023. REFER TO STRUCTURAL DRAWINGS FOR BUILDING EXCAVATION REQUIREMENTS. A. REFER TO PROJECT MANUAL FOR ADDITIONAL REQUIREMENTS. B. SITE CONDITIONS BASED UPON SURVEY SUBMITTED BY OWNER. FIELD VERIFY EXISTING CONDITIONS BY DETAILED SITE INSPECTION PRIOR TO SUBMITTING BID AND BEGINNING CONSTRUCTION. C. FIELD VERIFY SANITARY SEWER SERVICE CONNECTION INVERT PRIOR TO ESTABLISHING FINAL FINISH FLOOR ELEVATION. D. COORDINATE WORK WITH OTHER SITE RELATED DEVELOPMENT DRAWINGS. 1. PIPE MATERIALS SHALL BE IN ACCORDANCE WITH AND AS APPROVED BY THE CITY OR APPLICABLE AUTHORITY. REINFORCED CONCRETE PIPE (RCP), AND HIGH DENSITY POLYETHLYENE (HDPE). MAY BE USED AS ALLOWED BY LOCAL GUIDELINES. 2. ALL PIPE IS TO BE INSTALLED PER THE MANUFACTURER'S REQUIREMENTS AND MEET COVER REQUIREMENTS PER THE MANUFACTURER. INSTALL 45 L.F. 15" PIPE. FL IN = 21.6 FL OUT = 21.4. REFER TO PIPE NOTES. INSTALL MES AT END PER STANDARD PLANS FOR ROAD CONSTRUCTION INDEX 430-022. INSTALL 4' X 4' AREA INLET. RIM = 22.1' INV = 19.6' SUMP = 18.6' REFER TO DETAIL 1/C1.2. INSTALL 56 LF OF 15" Ø PIPE. INSTALL MES AT END OF PIPE. INV IN = 19.6' INV OUT = 19.5'. REFER TO PIPE NOTES. FOR PROPERTY LINE CROSS SECTION REFER TO DETAIL 7/C1.2 01-26-2024 05-08-2024 Digitally signed by Bryan Osborn Reason: Printed copies of this document are not considered signed and sealed, and the signature must be verified on any electronic copies. Date: 2024.05.08 14:06:12-05'00' Page 333 of 428 C1.2 PR O J E C T : NE W O ' R E I L L Y A U T O P A R T S S T O R E TU R N P I K E F E E D E R R D FO R T P I E R C E , F L # 4 SI T E G R A D I N G P L A N CO R P O R A T E O F F I C E S 23 3 S O U T H P A T T E R S O N SP R I N G F I E L D , M I S S O U R I 6 5 8 0 2 (4 1 7 ) 8 6 2 - 2 6 7 4 T E L E P H O N E REVISION DATE: DATE: COMM # BKR BDO22SP10143 4'X4' AREA INLET SCALE: NOT TO SCALEC1.2 1 48" 6"6" 36" VARIES 9" MIN NOTES: 1. INLET CAN BE SUBSTITUTED WITH ROUND EQUIVALENTS. 2. 12" SUMP REQUIRED PER COUNTY STANDARDS GROUNDEXISTING DRIVEWAY 25 ' M I N . EX I S T I N G P A V E M E N T 5:13'6" MIN. 50' SURGE STONE PAVEMENT EXISTING MOUNTABLE BERM 1. STONE SIZE - USE 3-6" STONE, OR EQUAL2. MIN. LENGTH - 50 FEET.3. MIN. THICKNESS - SIX(6) INCHES.4. WIDTH - TWENTY FIVE (25) FOOT MINIMUM5. FILTER CLOTH - WILL BE PLACED OVER THE ENTIRE AREA PRIOR TO PLACING OF STONE.6. SURFACE WATER - ALL SURFACE WATER FLOWING TOWARD THE CONSTRUCTIONEGRESS SHALL BE DIVERTED EITHER BY PIPE OR SWALES TO PREVENT THE WASHOUTOF THE EGRESS.7. MAINTENANCE - THE ENTRANCE SHALL BE MAINTAINED IN A CONDITION WHICH WILLPREVENT TRACKING OR FLOWING OF SEDIMENT ONTO PUBLIC RIGHTS-OF-WAY. THISMAY REQUIRE PERIODIC TOP DRESSING WITH ADDITIONAL STONE AS CONDITIONSDEMAND, AND REPAIR AND/OR CLEANOUT OF ANY MEASURES USED TO TRAP SEDIMENT.ALL SEDIMENT SPILLED, DROPPED, WASHED OR TRACKED ONTO PUBLIC RIGHTS-OF-WAYMUST BE REMOVED IMMEDIATELY. FILTREXX® 8" SOXX™CURB EXCESS SOXX™ MATERIAL TO BE DRAWN IN AND TIED OFF TO 2x2 WOODEN STAKE, (TYP.) SECURE SOXX™ TO GRATE WITH RUBBER TIE DOWNS CURB FILTREXX® 8" SOXX™ DRAIN INLET SECTION CURBSIDE OPTION "B" PLAN CURB FILTREXX® 8" SOXX™STORM GRATESTORM GRATE WIRE TIES, (TYP.) CURBSIDE OPTION "A" PLANDRAIN INLET PLAN EXCESS SOXX™ MATERIAL TO BE DRAWN IN AND TIED OFF TO 2x2 WOODEN STAKEFILTREXX® 8" SOXX™ CATCH BASINCATCH BASIN CURBSIDE SECTION 10' MIN VARIES 10 MIL PLASTIC LINER STRAW BALES, CONCRETE BLOCKS, SANDBAGS, ECT. STAKES (TYP) 4" 2" STAPLES (2 PER BALE)10 MIL PLASTIC LINER BINDING WIRE STRAW BALES NATIVE MATERIAL (OPTIONAL) WOOD OR OR METAL STAKES NOTES: 1. ACTUAL LAYOUT DETERMINED IN FIELD 2. THE CONCRETE WASHOUT SIGN SHALL BE INSTALLED WITHIN 30 FT. OF THE TEMPORARY CONCRETE WASHOUT FACILITY 3 1 3 1 ELEV = 19.0' BOTTOM OF POND TOP = 20.5'TOP = 20.5'SLOPE PR O P E R T Y L I N E PR O P O S E D B U I L D I N G PR O P E R T Y L I N E POND CROSS SECTION2 C1.2 SCALE: NOT TO SCALE SILT FENCE3 C1.2 SCALE: NOT TO SCALE CONSTRUCTION EGRESS4 C1.2 SCALE: NOT TO SCALE CONCRETE WASHOUT5 C1.2 SCALE: NOT TO SCALE INLET PROTECTION6 C1.2 SCALE: NOT TO SCALE 4712 06-16-2023 FDOT NOTES: MIN. 3 1 FFE = 24.0' EXISTING GROUND = 21.0'SLOPEPR O P E R T Y L I N E PR O P O S E D B U I L D I N G PR O P E R T Y L I N E PROPERTY LINE CROSS SECTION7 C1.2 SCALE: NOT TO SCALE 01-26-2024 05-08-2024 Digitally signed by Bryan Osborn Reason: Printed copies of this document are not considered signed and sealed, and the signature must be verified on any electronic copies. Date: 2024.05.08 14:05:49-05'00' Page 334 of 428 52116.750C S COR 13/141 COR 13/1 R 5575757575CORCOR 21 23 22 23 22 22 23 2 2 21 21 22 21 2 3 22 2322 21 21 21 20 21 22 20 24 21 22 23 23 22 21 22 2 3 23 2 3 2222222222 GRA D E B R E A K GR A D E B R E A K 22 2 3 23 21 21 21 21 21 21 PROPOSED DETENTIONPOND 20.5 19.5 19.5 20.5 23 23 23 23 GR A D E B R E A K 20.0 20.0 22 1 2222 12 22222 22 2121 3 AAAAA K 33 33 KKKKKKK AAAAAAA 222 33 AAAA KKK 22 3333 3333 GR GGGG DE AKAAAAAAAKAAAA EDEEDEDE GRGRGRRGR GGGGGGGGG EEEEEEE AKAKAAK R DE R AK EAEA RA2 BB D R 22 KEA BRBR ADDRG 23 3 3 3 RARA G AAAAA R 2 G GG DDD BR RE AEA K 3 23 2 K 33 2DE R KKK 3 GRA 3 RA E E 3 DDD KKK 22222 0.200 5557777 2122121 121 03 1 22 212 7C757575757575LCLCLCCLCN C557777991616166 33 2 3 2 3 2 3 222222222222222222222 2121 ORRRRR R020A13SSSCOOR 96996666NCCCCCCCOROOORORORORRRRRR3/1C CS3AA333SSSSSSCORRRORO 660N5755555C555OORRRRRRRRRRRRRRRRRR 4/C NCCC NCCC NNCCOOCCRRR R 14145557777777LLLL5577779955557777777LLLL55777753555.777777ALL6.567755777767536675756766NNNNNCCCNCNCNNCC15151555551551NNNNNNNN150501155551555555CCCC50105050115555NNNNNN15055CNCNCNCNNNCCCCNCCOOOOOOOOOOOCCCCOCCCCOOCOCOCOCOCOCOOOOOOOCOCOCOOCCCCCCCC3114/13/143/1414N N ROROROCOOCOOCOORRRR/1/114 CC39L13SL39ALC S39AAAA1133AL3AASLC SSCSSSOOOOOOOROROOROOOOOOORRRRRRR REAEAEAA 2020 202 20.50 0.5200 19.595 2 19.59 22 21 C1.3 PR O J E C T : NE W O ' R E I L L Y A U T O P A R T S S T O R E TU R N P I K E F E E D E R R D FO R T P I E R C E , F L # 4 ER O S I O N C O N T R O L P L A N CO R P O R A T E O F F I C E S 23 3 S O U T H P A T T E R S O N SP R I N G F I E L D , M I S S O U R I 6 5 8 0 2 (4 1 7 ) 8 6 2 - 2 6 7 4 T E L E P H O N E REVISION DATE: DATE: COMM # 1 C1.3 EROSION CONTROL PLAN SCALE: 1"= 20' BKR BDO22SP10143 FLOOD ZONE: EROSION CONTROL & MAINTENANCE PLAN NOTES: EROSION CONTROL STAGES OF CONSTRUCTION: KEY NOTES: LAND DISTURBANCE SUMMARY: 941 4712 06-16-2023 01-26-2024 05-08-2024 Digitally signed by Bryan Osborn Reason: Printed copies of this document are not considered signed and sealed, and the signature must be verified on any electronic copies. Date: 2024.05.08 14:05:33-05'00' Page 335 of 428 Page 336 of 428 21 23 2223 22 2 2 23 22 21 21 22 2 1 23 22 23 22 21 21 21 2 0 2 1 22 2 0 24 21 22 2 3 23 22 21 22 23 23 23 2 2 23 23 2 1 21 21 21 2 1 21 20.5 19.5 19.5 20.5 23 23 23 2 3 W UGT UGT UGT UGT U G T W W W TRASH PAD 40 67 O'Reilly Auto Parts 86'-4" X 86'-4" SQ.FT. = 7,627 SR.FLOOR ELEVATION: 000.00' 1515 95 TURNPIKE FEEDER RD /HWY 713 P K W Y ( 7 0 ' W I D E ) PA L O M A R ABACA DR DEL E O N A V E ( 7 0 ' W I D E ) 101 SANSANSANSAN W W SA N SAN SAN 56 EASEMENT(TYP.) PROPOSED DETENTION POND 1 5 ' L A N D S C A P E S E T B A C K 15' LANDSCAPE SETBACK 15' LANDSCAPE SETBACK 38 26 15 24 48 10 ' L A N D S C A P E B U F F E R 54 34 13 9 92 111 56 SIGHT TRIANGLE ·ALL PLANT BEDS SHALL CONTAIN A 3" LAYER OF PINE NEEDLE MULCH. NON-CYPRESS MULCH SHALL NOT BE USED PER LDC 7.09.04.L.3 ·CONTRACTOR TO PLACE 4' DIAMETER MULCH RING AROUND ALL TREES IN LAWN MULCH LANDSCAPE REQUIREMENTS BUFFERS HWY 713 (150 LF) REQUIRED WIDTH: 10 FT PROPOSED WIDTH: 10 FT REQUIRED CANOPY TREES:5 (1 TREE PER 30 LF) PROPOSED CANOPY TREES: 5 REQUIRED SHRUBS: HEDGE ALONG STRIP PROPOSED SHRUBS: HEDGE ALONG STRIP PALOMAR PKWY (231 LF) REQUIRED WIDTH: 10 FT PROPOSED WIDTH: 10 FT REQUIRED CANOPY TREES:8 (1 TREE PER 30 LF) PROPOSED CANOPY TREES: 8 REQUIRED SHRUBS: HEDGE ALONG STRIP PROPOSED SHRUBS: HEDGE ALONG STRIP ABACA DR PKWY (261 LF) REQUIRED WIDTH: 10 FT PROPOSED WIDTH: 10 FT REQUIRED CANOPY TREES:9 (1 TREE PER 30 LF) PROPOSED CANOPY TREES: 9 REQUIRED SHRUBS: HEDGE ALONG STRIP PROPOSED SHRUBS: HEDGE ALONG STRIP DELEON AVE (38 LF) REQUIRED WIDTH: 10 FT PROPOSED WIDTH: 10 FT REQUIRED CANOPY TREES:2 (1 TREE PER 30 LF) PROPOSED CANOPY TREES: 2 REQUIRED SHRUBS: HEDGE ALONG STRIP PROPOSED SHRUBS: HEDGE ALONG STRIP ADJACENT PROPERTY REQUIRED WIDTH: 10 FT PROPOSED WIDTH:10 FT REQUIRED CANOPY TREES:9 (1 TREE PER 30 LF) PROPOSED CANOPY TREES: 9 REQUIRED SHRUBS: HEDGE ALONG STRIP PROPOSED SHRUBS: HEDGE ALONG STRIP INTERIOR LANDSCAPING: SURFACE PARKING/VUA (18,194 SF) REQUIRED TREES: 4 (1 TREE EVERY 10 SPACES) PROPOSED TREES: 4 REQUIRED LANDSCAPING: 1,011 SF (1 PER 18SF VUA) PROPOSED LANDSCAPING: 1,493 SF REQUIRED SHADE TREES: 7 (1 PER TERMINAL ISLAND) PROPOSED SHADE TREES: 7 INTERIM DESIGN STANDARDS TOTAL LANDSCAPED AREA (22,811 SF) TOTAL GROUNDCOVER (958) REQUIRED SEASONAL FLOWERS: 89 (10% TOTAL GROUNDCOVER) PROPOSED SEASONAL FLOWERS: 958 PROPOSED SOD COVERAGE: 11,244 SF (49.29%) EXISTING TREES TO REMAIN CONTRACTOR TO PROTECT WITHIN DRIP LINES SEE TREE PROTECTION & DEMOLITION PLANS TREES QTY BOTANICAL / COMMON NAME SIZE MIN HT / SPR SPACING 5 LAGERSTROEMIA INDICA X FAURIEI `NATCHEZ`2.5" DBH 12-14` HT AS SHOWN NATCHEZ CRAPE MYRTLE 7 QUERCUS VIRGINIANA `QVTIA`2.5" DBH 12-14` HT AS SHOWN HIGHRISE LIVE OAK 18 TAXODIUM DISTICHUM 2.5" DBH 12-14` HT AS SHOWN BALD CYPRESS 9 ULMUS ALATA 2.5" DBH 12-14` HT AS SHOWN WINGED ELM NATIVE TREES QTY BOTANICAL / COMMON NAME SIZE MIN HT / SPR SPACING 10 ACER RUBRUM 'FLORIDA FLAME'2.5" CAL 12-14` HT AS SHOWN FLORIDA FLAME RED MAPLE SHRUBS QTY BOTANICAL / COMMON NAME SIZE MIN HT / SPR SPACING 57 CROTON DISCOLOR ---36" HT 3`-0" OC CROTON 32 PODOCARPUS MACROPHYLLUS ---48" HT 4`-0" OC YEW PODOCARPUS 89 SCHEFFLERA ARBORICOLA 'DWARF'---36" HT 3`-6" OC DWARF SCHEFFLERA 187 VIBURNUM OBOVATUM ---24" HT 3`-6" OC WALTER`S VIBURNUM GROUND COVERS QTY BOTANICAL / COMMON NAME SIZE MIN HT / SPR SPACING 354 HEMEROCALLIS X 'HAPPY RETURNS'1 GAL 1`-6" OC HAPPY RETURNS DAYLILY 604 LIRIOPE MUSCARI 'SUPER BLUE'1 GAL 1`-0" OC SUPER BLUE LILYTURF SOD QTY BOTANICAL / COMMON NAME SIZE MIN HT / SPR SPACING 24,861 SF PASPALUM NOTATUM SOD BAHIAGRASS PLANT SCHEDULE NUMBER INDICATED ON HATCH THROUGHOUT THE DRAWING REFLECTS THE NUMBER OF PLANTS IN THAT PARTICULAR AREA 401 TREE MIX: 4,637SF OR 140 TREES CONTRACTOR TO INSTALL MIX OF 2.5" DBH TREES SPACED APPROXIMATELY 5' O.C. MIX OF TREES TO INCLUDE THE FOLLOWING SPECIES: 1/3 SLASH PINE 2/3 LIVE OAK / LAUREL OAK DESIGN NOTE: INTENT IS FOR SPECIES TO BE INSTALLED IN ONE GROUPING FOR NATURAL/RANDOM MIX 0 10 20 40 SCALE: 1"=20'-0" PR O J E C T : NE W O ' R E I L L Y A U T O P A R T S S T O R E TU R N P I K E F E E D E R R D . FO R T P I E R C E , F L # 4 CO R P O R A T E O F F I C E S 23 3 S O U T H P A T T E R S O N SP R I N G F I E L D , M I S S O U R I 6 5 8 0 2 (4 1 7 ) 8 6 2 - 2 6 7 4 T E L E P H O N E AU T O P A R T S REVISION DATE: DATE:06/16/2023 COMM # 4712 17 3 6 E a s t S u n s h i n e , S u i t e 4 1 7 Sp r i n g f i e l d , M i s s o u r i 6 5 8 0 4 Fa x : 4 1 7 . 8 6 2 . 3 2 6 5 e- m a i l : a r c h i t e c t @ e s t e r l y s c h n e i d e r . c o m 41 7 . 8 6 2 . 0 5 5 8 CRA I G A. SCH N E I D E R , AI A AR C H I T E C T NEW LIGHT POLE LOCATION PROPERTY LINE RIGHT-OF-WAY SYMBOLS LEGEND REFER TO SURVEY FOR EXISTING CONDITION SYMBOLS LEGEND NEW BUILDING CONSTRUCTION AREA OF CONCRETE NEW POLE SIGN LOCATION KEY NOTES: EXISTING OVERHEAD POWER/ UTILITY LINES PROPOSED SIDEWALK EXISTING SIDEWALK EXISTING WATER LINE BIKE RACK MONUMENT SIGN 1 2 3 4 5 6 1 2 3 4 PL A N T I N G P L A N L1 OF 6 5 01/26/2024 NOTE: SEEKING RELIEF WITH REQUIRED BUFFER PLANTING DUE TO PROXIMITY TO ADJACENT WOODED AREA EXISTING TREE CHART TREE TO BE REMOVED - NUMBER IN SYMBOL CORRELATES WITH EXISTING TREE CHART LOCATED ON SHEET L2 TREE TO BE RETAINED - NUMBER IN SYMBOL CORRELATES WITH EXISTING TREE CHART LOCATED ON SHEET L2 05/21/2024 NOTE: PLANT MATERIALS USED ARE TO MEET FLORIDA No.1 GRADE MATERIAL OR BETTER PER LDC 7.09.03.E.1 6 Page 337 of 428 Tree Number DBH (Inches)Species*DBH TOTAL (Inches) Remove (R) or Keep (K)Replacement Ratio Replacement Inches Preserved Ratio Preservation Credits (Inches) Preservation Credits (Palms) 1 20 SAPA 20 R 0 0 2 14 SAPA 14 R 0 0 3 15 SAPA 15 R 0 0 4 12 SAPA 12 R 0 0 5 18 SAPA 18 R 0 0 6 15 SAPA 15 R 0 0 7 13 SAPA 13 R 0 0 8 16 SAPA 16 R 0 0 9 33 QULA 33 R 2:1 66 10 13 SAPA 13 R 0 0 11 18 QULA 18 R 2:1 36 12 18 QULA 18 R 2:1 36 13 15,10 QUVI 25 R 2:1 50 14 15 SAPA 15 R 0 0 15 14 PIEL 14 R 2:1 28 16 23 QUVI 23 R 2:1 46 17 12 PIEL 12 R 2:1 24 18 10,8 PIEL 18 R 2:1 36 19 13 PIEL 13 R 2:1 26 20 14 SAPA 14 R 0 0 21 13 SAPA 13 R 0 0 22 13 SAPA 13 R 0 0 23 13 SAPA 13 R 0 0 24 19 PIEL 19 R 2:1 38 25 11 SAPA 11 R 0 0 26 11 SAPA 11 R 0 0 27 13 SAPA 13 R 0 0 28 21 PIEL 21 R 2:1 42 29 13 SAPA 13 R 0 0 30 13 SAPA 13 R 0 0 34 12 PIEL 12 R 2:1 24 35 17 SAPA 17 R 0 0 36 11 SAPA 11 R 0 0 37 11 SAPA 11 R 0 0 38 15 SAPA 15 R 0 0 39 17 PIEL 17 R 2:1 34 40 15 SAPA 15 R 0 0 46 15 SAPA 15 R 0 0 47 12 PIEL 12 R 2:1 12 48 17 SAPA 17 R 0 0 49 13 PIEL 13 R 2:1 26 50 26 QULA 26 R 2:1 52 52 10 SAPA 10 R 0 0 53 13 SAPA 13 R 0 0 54 18 SAPA 18 R 0 0 55 14 QULA 14 R 2:1 28 56 15 SAPA 15 R 0 0 57 14 QULA 14 R 2:1 28 58 16 SAPA 16 R 0 0 59 10 SAPA 10 R 0 0 60 13 SAPA 13 R 0 0 61 12 SAPA 12 R 0 0 62 23 PIEL 23 R 2:1 46 63 17 PIEL 17 R 2:1 34 64 14 SAPA 14 R 0 0 66 12 SAPA 12 R 0 0 67 16 SAPA 16 R 0 0 68 11 SAPA 11 R 0 0 69 18 PIEL 18 R 2:1 36 70 18 PIEL 18 R 2:1 36 71 18 SAPA 18 R 0 0 72 15 SAPA 15 R 0 0 73 11 SAPA 11 R 0 0 75 13 SAPA 13 R 0 0 76 13 SAPA 13 R 0 0 77 15 PIEL 15 R 2:1 30 78 9 SAPA 9 R 0 0 79 12 SAPA 12 R 0 0 80 12,12,9 QULA 33 R 2:1 33 81 14 QULA 14 R 2:1 28 82 9,9 QULA 18 R 2:1 36 83 15 SAPA 15 R 0 0 84 17 PIEL 17 R 2:1 34 89 13 SAPA 13 R 0 0 90 10 SAPA 10 R 0 0 91 13 PIEL 13 R 2:1 26 92 18 SAPA 18 R 0 0 93 14 SAPA 14 R 0 0 95 11 SAPA 11 R 0 0 96 10 SAPA 10 R 0 0 97 16 SAPA 16 K 0 0 1:1 1 99 16 SAPA 16 R 0 0 100 16 SAPA 16 R 0 0 101 16 SAPA 16 R 0 0 102 16 SAPA 16 R 0 0 103 15 SAPA 15 R 0 0 104 12 SAPA 12 R 0 0 105 17 QULA 17 R 2:1 34 106 14,12 QULA 26 R 2:1 26 107 20 PIEL 20 R 2:1 40 108 9 SAPA 9 R 0 0 109 12 SAPA 12 R 0 0 110 12 SAPA 12 R 0 0 111 11 SAPA 11 R 0 0 112 16 PIEL 16 R 2:1 32 113 16 QULA 16 R 2:1 32 114 12 PIEL 12 R 2:1 24 115 16 SAPA 16 K 0 0 1:1 1 116 10 SAPA 10 K 0 0 1:1 1 117 17 SAPA 17 K 0 0 1:1 1 118 18 PIEL 18 R 2:1 36 119 10,9 QULA 19 R 2:1 38 120 16 QULA 16 R 2:1 32 121 12 SAPA 12 R 0 0 124 12 SAPA 12 R 0 0 127 9 SAPA 9 R 0 0 128 14 SAPA 14 R 0 0 130 12 QULA 12 K 1:2 24 131 10 SAPA 10 R 0 0 132 13 SAPA 13 K 0 0 1:1 1 133 13 SAPA 13 K 0 0 1:1 1 134 16 SAPA 16 R 0 0 135 19 SAPA 19 R 0 0 136 13 QULA 13 R 2:1 26 137 16 SAPA 16 R 0 0 138 14 PIEL 14 R 2:1 28 139 12 QULA 12 R 2:1 24 140 14 QULA 14 R 2:1 28 141 12 QULA 12 K 1:2 24 142 QULA 8 R 2:1 16 143 18 PIEL 18 R 2:1 36 8142 Tree Number DBH (Inches)Species*DBH TOTAL (Inches) Remove (R) or Keep (K)Replacement Ratio Replacement Inches Preserved Ratio Preservation Credits (Inches) Preservation Credits (Palms) TOTAL OAKS 22 TOTAL OAKS TBR 20 TOTAL PINES 23 TOTAL PINES TBR 23 TOTAL PALMS 76 TOTAL PALMS TBR 70 TOTALS 121 1,423 TOTAL MITIGATION REQUIRED 1,375 QTY AMOUNT TOTAL MITIGATION PAYMENT - OAK 389 (INCHES)$77,800.00 TOTAL MITIGATION PAYMENT - PINE 370 (INCHES)$74,000.00 TOTAL MITIGATION PAYMENT - PALM 70 (PALMS)$14,000.00 SUBTOTAL:$165,800.00 QTY AMOUNT SUMMARY OF PRESERVED - OAKS 48 (INCHES)-$9,600.00 SUMMARY OF PRESERVED - PINES 0 (INCHES)- SUMMARY OF PRESERVED - PALMS 6 (PALMS)-$1,200.00 SUBTOTAL:-$10,800.00 QTY AMOUNT SUMMARY OF PROPOSED 472.5 (INCHES)-$94,500.00 SUBTOTAL:-$94,500.00 SUMMARY OF OWED TOTAL:$60,500.00 PR O J E C T : NE W O ' R E I L L Y A U T O P A R T S S T O R E TU R N P I K E F E E D E R R D . FO R T P I E R C E , F L # 4 CO R P O R A T E O F F I C E S 23 3 S O U T H P A T T E R S O N SP R I N G F I E L D , M I S S O U R I 6 5 8 0 2 (4 1 7 ) 8 6 2 - 2 6 7 4 T E L E P H O N E AU T O P A R T S REVISION DATE: DATE:06/16/2023 COMM # 4712 17 3 6 E a s t S u n s h i n e , S u i t e 4 1 7 Sp r i n g f i e l d , M i s s o u r i 6 5 8 0 4 Fa x : 4 1 7 . 8 6 2 . 3 2 6 5 e- m a i l : a r c h i t e c t @ e s t e r l y s c h n e i d e r . c o m 41 7 . 8 6 2 . 0 5 5 8 CRA I G A. SCH N E I D E R , AI A AR C H I T E C T TR E E M I T I G A T I O N L2 OF 6 *SPECIES: Cabbage/Sabal Palm, Sabal palmetto (SAPA) Slash Pine, Pinus elliottii (PIEL) Live Oak, Quercus virginiana (QUVI) Laurel Oak, Quercus laurifolia (QULA) 01/26/2024 05/21/2024 Page 338 of 428 P K W Y ( 7 0 ' W I D E ) P A L O M A R ABACA DR TRASH PAD TURNPIKE FEEDER RD /HWY 713 P K W Y ( 7 0 ' W I D E ) P A L O M A R ABACA DR DEL E O N A V E ( 7 0 ' W I D E ) O'Reilly Auto Parts 86'-4" X 86'-4" SQ.FT. = 7,627 SR.FLOOR ELEVATION: 000.00' PROPOSED DETENTION POND MFG.: LEEMCO FITTINGS (MODEL: LBT-XX-SS) GENERAL NOTES: 1.IRRIGATION SYSTEM DESIGN BASED ON 30 GPM AND 75 PSI. 2.IRRIGATION DESIGN IS FROM THE POINT OF CONNECTION (POC) ONLY. THE DESIGN IS BASED ON GALLONS PER MINUTE (GPM) AND POUNDS PER SQUARE INCH (PSI) AS FURNISHED BY OTHERS. 3.IRRIGATION CONTRACTOR TO VERIFY POINT OF CONNECTION IN THE FIELD AND CONFIRM MINIMUM DISCHARGE REQUIRED AT POINT OF CONNECTION AS REQUIRED BY PROPOSED IRRIGATION EQUIPMENT PRIOR TO INSTALLATION. CONTACT OWNER'S REPRESENTATIVE WITH ANY DISCREPANCIES IMMEDIATELY BEFORE INSTALLATION. 4.THE PRESSURE REQUIREMENT AT THE POINT OF CONNECTION IS BASED ON NO MORE THAN 5 FEET OF ELEVATION CHANGE IN THE AREAS OF IRRIGATION. 5.CONTRACTOR TO USE CONTINUOUS RUNS FOR ALL PROPOSED CONTROL WIRES. IF NECESSARY, LOCATE ALL WIRE SPLICES IN VALVE BOX. BUNDLE WIRES IN VALVE BOX WITH MINIMUM 24" OF EXCESS CABLE PER BUNDLE. ALL SPLICES MUST BE WATERPROOF WITH 3M DBY/DBR-6 CONNECTORS. 6.PIPE LOCATIONS ARE DIAGRAMMATIC. VALVES AND MAINLINE SHOWN IN PAVED AREAS ARE FOR GRAPHIC CLARITY ONLY. 7.ALL MATERIAL USED SHALL BE INSTALLED AS PER PLAN AND AS PER MANUFACTURER'S SPECIFICATIONS. ALL DEVIATIONS FROM DRAWINGS OR MATERIALS SHALL BE APPROVED BY THE OWNER OR LANDSCAPE ARCHITECT. 8.CONTRACTOR TO PROVIDE ANY STAKING NECESSARY FOR PROPERTY LINES, EASEMENT LINES, ETC. TO INSTALL PLANTING AND IRRIGATION AS PER PLANS. 9.LOCATE VALVES AND VALVE BOXES IN SHRUB BED WHENEVER POSSIBLE. IF NECESSARY TO LOCATE IN LAWN, LOCATE A MINIMUM OF 36" AWAY FROM PLANTER BED EDGE. 10.SEE DETAIL SHEET L301 & L302 FOR FURTHER IRRIGATION NOTES & DETAILS 0 10 20 40 SCALE: 1"=20'-0" PR O J E C T : NE W O ' R E I L L Y A U T O P A R T S S T O R E TU R N P I K E F E E D E R R D . FO R T P I E R C E , F L # 4 CO R P O R A T E O F F I C E S 23 3 S O U T H P A T T E R S O N SP R I N G F I E L D , M I S S O U R I 6 5 8 0 2 (4 1 7 ) 8 6 2 - 2 6 7 4 T E L E P H O N E AU T O P A R T S REVISION DATE: DATE:06/16/2023 COMM # 4712 17 3 6 E a s t S u n s h i n e , S u i t e 4 1 7 Sp r i n g f i e l d , M i s s o u r i 6 5 8 0 4 Fa x : 4 1 7 . 8 6 2 . 3 2 6 5 e- m a i l : a r c h i t e c t @ e s t e r l y s c h n e i d e r . c o m 41 7 . 8 6 2 . 0 5 5 8 CRA I G A. SCH N E I D E R , AI A AR C H I T E C T 8 5 4 6 7 2 1 PROPERTY LINE RIGHT-OF-WAY SYMBOLS LEGEND REFER TO SURVEY FOR EXISTING CONDITION SYMBOLS LEGEND NEW BUILDING CONSTRUCTION AREA OF CONCRETE NEW POLE SIGN LOCATION IR R I G A T I O N P L A N 4 2 L3 OF 6 KEY NOTES: ALL PROPOSED LAWN AREAS THAT HAVE NOT BEEN HATCHED WITH DRIP AREA HATCHING AND DO NOT CONTAIN EXISTING PLANT MATERIAL WILL BE IRRIGATED WITH SPRAY HEAD IRRIGATION OR ROTORS UNLESS OTHERWISE NOTED (TYP.). POND AREAS TO BE ZONED SEPARATELY. PLANTER BED IRRIGATION COVERAGE (TYP. OF HATCHED AREAS). ALL PROPOSED PLANTINGS SHALL RECEIVE DRIP IRRIGATION POINT OF CONNECTION IS A SEPARATE WATER METER WITH A BACKFLOW PREVENTER. REFER TO CIVIL SET FOR FURTHER INFORMATION 2" IRRIGATION MAINLINE (TYP.) - SOLVENT WELD PVC - ASTM D2241 - CLASS 200 - SDR 21 CONTRACTOR WILL BE REQUIRED TO LOOP THE IRRIGATION MAINLINE TO REDUCE PRESSURE LOSS IF NEEDED NOTE: MAINLINE LAYOUT IS DIAGRAMMATIC. VALVES AND MAINLINE SHOWN IN PAVED AREAS ARE FOR GRAPHIC CLARITY ONLY. ALL VALVES AND MAINLINE SHALL BE INSTALLED WITHIN LANDSCAPE AREAS. CONTRACTOR SHALL NOT ROUTE MAINLINE NEAR EXISTING OR PROPOSED TREES, OR UTILITY LINES. REFER TO CIVIL SET FOR MORE INFORMATION PRIOR TO INSTALLATION. UNDERPAVEMENT SLEEVING (TYP.) - SCHEDULE 40 PIPE: 4" DIAMETER UNLESS OTHERWISE INDICATED. TO BE INSTALLED BY LANDSCAPE CONTRACTOR AT DEPTH AS PER LOCAL CODE. AUTOMATIC CONTROLLER: MOUNT CONTROLLER ON BACK OF WALL IF ACCEPTABLE WITH OWNER POTENTIAL LOCATION FOR WIRELESS MINI WEATHER STATION/ RAIN SENSOR: MOUNT RAIN SENSOR ON TOP OF BUILDING IF ACCEPTABLE WITH OWNER. ENSURE SENSOR IS OUT OF EXISTING AND FUTURE DRIPLINES OF TREES STAINLESS STEEL BALL VALVE (TYP.) - SIZE PER LINE SIZE MFG.: LEEMCO FITTINGS (MODEL: LBT-XX-SS) CONTRACTOR TO HAND-WATER TREE MIX AREA UNTIL ESTABLISHMENT 1 2 3 4 5 6 7 8 9 2 5 5 2 2 8 2 2 2 2 9 9 2 01/26/2024 2 3 05/21/2024 Page 339 of 428 Page 340 of 428 Page 341 of 428 Page 342 of 428 Page 343 of 428 21 23 2223 22 2 2 23 22 21 21 22 2 1 23 22 23 22 21 21 21 2 0 2 1 22 2 0 24 21 22 2 3 23 22 21 22 23 23 23 2 2 23 23 2 1 21 21 21 2 1 21 20.5 19.5 19.5 20.5 23 23 23 2 3 W UGT UGT UGT UGT U G T W W W TRASH PAD 40 67 O'Reilly Auto Parts 86'-4" X 86'-4" SQ.FT. = 7,627 SR.FLOOR ELEVATION: 000.00' 1515 95 TURNPIKE FEEDER RD /HWY 713 P K W Y ( 7 0 ' W I D E ) PA L O M A R ABACA DR DEL E O N A V E ( 7 0 ' W I D E ) 101 SANSANSANSAN W W SA N SAN SAN 56 EASEMENT(TYP.) PROPOSED DETENTION POND 1 5 ' L A N D S C A P E S E T B A C K 15' LANDSCAPE SETBACK 15' LANDSCAPE SETBACK 38 26 15 24 48 10 ' L A N D S C A P E B U F F E R 54 34 13 9 92 111 56 SIGHT TRIANGLE ·ALL PLANT BEDS SHALL CONTAIN A 3" LAYER OF PINE NEEDLE MULCH. NON-CYPRESS MULCH SHALL NOT BE USED PER LDC 7.09.04.L.3 ·CONTRACTOR TO PLACE 4' DIAMETER MULCH RING AROUND ALL TREES IN LAWN MULCH LANDSCAPE REQUIREMENTS BUFFERS HWY 713 (150 LF) REQUIRED WIDTH: 10 FT PROPOSED WIDTH: 10 FT REQUIRED CANOPY TREES:5 (1 TREE PER 30 LF) PROPOSED CANOPY TREES: 5 REQUIRED SHRUBS: HEDGE ALONG STRIP PROPOSED SHRUBS: HEDGE ALONG STRIP PALOMAR PKWY (231 LF) REQUIRED WIDTH: 10 FT PROPOSED WIDTH: 10 FT REQUIRED CANOPY TREES:8 (1 TREE PER 30 LF) PROPOSED CANOPY TREES: 8 REQUIRED SHRUBS: HEDGE ALONG STRIP PROPOSED SHRUBS: HEDGE ALONG STRIP ABACA DR PKWY (261 LF) REQUIRED WIDTH: 10 FT PROPOSED WIDTH: 10 FT REQUIRED CANOPY TREES:9 (1 TREE PER 30 LF) PROPOSED CANOPY TREES: 9 REQUIRED SHRUBS: HEDGE ALONG STRIP PROPOSED SHRUBS: HEDGE ALONG STRIP DELEON AVE (38 LF) REQUIRED WIDTH: 10 FT PROPOSED WIDTH: 10 FT REQUIRED CANOPY TREES:2 (1 TREE PER 30 LF) PROPOSED CANOPY TREES: 2 REQUIRED SHRUBS: HEDGE ALONG STRIP PROPOSED SHRUBS: HEDGE ALONG STRIP ADJACENT PROPERTY REQUIRED WIDTH: 10 FT PROPOSED WIDTH:10 FT REQUIRED CANOPY TREES:9 (1 TREE PER 30 LF) PROPOSED CANOPY TREES: 9 REQUIRED SHRUBS: HEDGE ALONG STRIP PROPOSED SHRUBS: HEDGE ALONG STRIP INTERIOR LANDSCAPING: SURFACE PARKING/VUA (18,194 SF) REQUIRED TREES: 4 (1 TREE EVERY 10 SPACES) PROPOSED TREES: 4 REQUIRED LANDSCAPING: 1,011 SF (1 PER 18SF VUA) PROPOSED LANDSCAPING: 1,493 SF REQUIRED SHADE TREES: 7 (1 PER TERMINAL ISLAND) PROPOSED SHADE TREES: 7 INTERIM DESIGN STANDARDS TOTAL LANDSCAPED AREA (22,811 SF) TOTAL GROUNDCOVER (958) REQUIRED SEASONAL FLOWERS: 89 (10% TOTAL GROUNDCOVER) PROPOSED SEASONAL FLOWERS: 958 PROPOSED SOD COVERAGE: 11,244 SF (49.29%) EXISTING TREES TO REMAIN CONTRACTOR TO PROTECT WITHIN DRIP LINES SEE TREE PROTECTION & DEMOLITION PLANS TREES QTY BOTANICAL / COMMON NAME SIZE MIN HT / SPR SPACING 5 LAGERSTROEMIA INDICA X FAURIEI `NATCHEZ`2.5" DBH 12-14` HT AS SHOWN NATCHEZ CRAPE MYRTLE 7 QUERCUS VIRGINIANA `QVTIA`2.5" DBH 12-14` HT AS SHOWN HIGHRISE LIVE OAK 18 TAXODIUM DISTICHUM 2.5" DBH 12-14` HT AS SHOWN BALD CYPRESS 9 ULMUS ALATA 2.5" DBH 12-14` HT AS SHOWN WINGED ELM NATIVE TREES QTY BOTANICAL / COMMON NAME SIZE MIN HT / SPR SPACING 10 ACER RUBRUM 'FLORIDA FLAME'2.5" CAL 12-14` HT AS SHOWN FLORIDA FLAME RED MAPLE SHRUBS QTY BOTANICAL / COMMON NAME SIZE MIN HT / SPR SPACING 57 CROTON DISCOLOR ---36" HT 3`-0" OC CROTON 32 PODOCARPUS MACROPHYLLUS ---48" HT 4`-0" OC YEW PODOCARPUS 89 SCHEFFLERA ARBORICOLA 'DWARF'---36" HT 3`-6" OC DWARF SCHEFFLERA 187 VIBURNUM OBOVATUM ---24" HT 3`-6" OC WALTER`S VIBURNUM GROUND COVERS QTY BOTANICAL / COMMON NAME SIZE MIN HT / SPR SPACING 354 HEMEROCALLIS X 'HAPPY RETURNS'1 GAL 1`-6" OC HAPPY RETURNS DAYLILY 604 LIRIOPE MUSCARI 'SUPER BLUE'1 GAL 1`-0" OC SUPER BLUE LILYTURF SOD QTY BOTANICAL / COMMON NAME SIZE MIN HT / SPR SPACING 24,861 SF PASPALUM NOTATUM SOD BAHIAGRASS PLANT SCHEDULE NUMBER INDICATED ON HATCH THROUGHOUT THE DRAWING REFLECTS THE NUMBER OF PLANTS IN THAT PARTICULAR AREA 401 TREE MIX: 4,637SF OR 140 TREES CONTRACTOR TO INSTALL MIX OF 2.5" DBH TREES SPACED APPROXIMATELY 5' O.C. MIX OF TREES TO INCLUDE THE FOLLOWING SPECIES: 1/3 SLASH PINE 2/3 LIVE OAK / LAUREL OAK DESIGN NOTE: INTENT IS FOR SPECIES TO BE INSTALLED IN ONE GROUPING FOR NATURAL/RANDOM MIX 0 10 20 40 SCALE: 1"=20'-0" PR O J E C T : NE W O ' R E I L L Y A U T O P A R T S S T O R E TU R N P I K E F E E D E R R D . FO R T P I E R C E , F L # 4 CO R P O R A T E O F F I C E S 23 3 S O U T H P A T T E R S O N SP R I N G F I E L D , M I S S O U R I 6 5 8 0 2 (4 1 7 ) 8 6 2 - 2 6 7 4 T E L E P H O N E AU T O P A R T S REVISION DATE: DATE:06/16/2023 COMM # 4712 17 3 6 E a s t S u n s h i n e , S u i t e 4 1 7 Sp r i n g f i e l d , M i s s o u r i 6 5 8 0 4 Fa x : 4 1 7 . 8 6 2 . 3 2 6 5 e- m a i l : a r c h i t e c t @ e s t e r l y s c h n e i d e r . c o m 41 7 . 8 6 2 . 0 5 5 8 CRA I G A. SCH N E I D E R , AI A AR C H I T E C T NEW LIGHT POLE LOCATION PROPERTY LINE RIGHT-OF-WAY SYMBOLS LEGEND REFER TO SURVEY FOR EXISTING CONDITION SYMBOLS LEGEND NEW BUILDING CONSTRUCTION AREA OF CONCRETE NEW POLE SIGN LOCATION KEY NOTES: EXISTING OVERHEAD POWER/ UTILITY LINES PROPOSED SIDEWALK EXISTING SIDEWALK EXISTING WATER LINE BIKE RACK MONUMENT SIGN 1 2 3 4 5 6 1 2 3 4 PL A N T I N G P L A N L1 OF 6 5 01/26/2024 NOTE: SEEKING RELIEF WITH REQUIRED BUFFER PLANTING DUE TO PROXIMITY TO ADJACENT WOODED AREA EXISTING TREE CHART TREE TO BE REMOVED - NUMBER IN SYMBOL CORRELATES WITH EXISTING TREE CHART LOCATED ON SHEET L2 TREE TO BE RETAINED - NUMBER IN SYMBOL CORRELATES WITH EXISTING TREE CHART LOCATED ON SHEET L2 05/21/2024 NOTE: PLANT MATERIALS USED ARE TO MEET FLORIDA No.1 GRADE MATERIAL OR BETTER PER LDC 7.09.03.E.1 6 Page 344 of 428 Tree Number DBH (Inches)Species*DBH TOTAL (Inches) Remove (R) or Keep (K)Replacement Ratio Replacement Inches Preserved Ratio Preservation Credits (Inches) Preservation Credits (Palms) 1 20 SAPA 20 R 0 0 2 14 SAPA 14 R 0 0 3 15 SAPA 15 R 0 0 4 12 SAPA 12 R 0 0 5 18 SAPA 18 R 0 0 6 15 SAPA 15 R 0 0 7 13 SAPA 13 R 0 0 8 16 SAPA 16 R 0 0 9 33 QULA 33 R 2:1 66 10 13 SAPA 13 R 0 0 11 18 QULA 18 R 2:1 36 12 18 QULA 18 R 2:1 36 13 15,10 QUVI 25 R 2:1 50 14 15 SAPA 15 R 0 0 15 14 PIEL 14 R 2:1 28 16 23 QUVI 23 R 2:1 46 17 12 PIEL 12 R 2:1 24 18 10,8 PIEL 18 R 2:1 36 19 13 PIEL 13 R 2:1 26 20 14 SAPA 14 R 0 0 21 13 SAPA 13 R 0 0 22 13 SAPA 13 R 0 0 23 13 SAPA 13 R 0 0 24 19 PIEL 19 R 2:1 38 25 11 SAPA 11 R 0 0 26 11 SAPA 11 R 0 0 27 13 SAPA 13 R 0 0 28 21 PIEL 21 R 2:1 42 29 13 SAPA 13 R 0 0 30 13 SAPA 13 R 0 0 34 12 PIEL 12 R 2:1 24 35 17 SAPA 17 R 0 0 36 11 SAPA 11 R 0 0 37 11 SAPA 11 R 0 0 38 15 SAPA 15 R 0 0 39 17 PIEL 17 R 2:1 34 40 15 SAPA 15 R 0 0 46 15 SAPA 15 R 0 0 47 12 PIEL 12 R 2:1 12 48 17 SAPA 17 R 0 0 49 13 PIEL 13 R 2:1 26 50 26 QULA 26 R 2:1 52 52 10 SAPA 10 R 0 0 53 13 SAPA 13 R 0 0 54 18 SAPA 18 R 0 0 55 14 QULA 14 R 2:1 28 56 15 SAPA 15 R 0 0 57 14 QULA 14 R 2:1 28 58 16 SAPA 16 R 0 0 59 10 SAPA 10 R 0 0 60 13 SAPA 13 R 0 0 61 12 SAPA 12 R 0 0 62 23 PIEL 23 R 2:1 46 63 17 PIEL 17 R 2:1 34 64 14 SAPA 14 R 0 0 66 12 SAPA 12 R 0 0 67 16 SAPA 16 R 0 0 68 11 SAPA 11 R 0 0 69 18 PIEL 18 R 2:1 36 70 18 PIEL 18 R 2:1 36 71 18 SAPA 18 R 0 0 72 15 SAPA 15 R 0 0 73 11 SAPA 11 R 0 0 75 13 SAPA 13 R 0 0 76 13 SAPA 13 R 0 0 77 15 PIEL 15 R 2:1 30 78 9 SAPA 9 R 0 0 79 12 SAPA 12 R 0 0 80 12,12,9 QULA 33 R 2:1 33 81 14 QULA 14 R 2:1 28 82 9,9 QULA 18 R 2:1 36 83 15 SAPA 15 R 0 0 84 17 PIEL 17 R 2:1 34 89 13 SAPA 13 R 0 0 90 10 SAPA 10 R 0 0 91 13 PIEL 13 R 2:1 26 92 18 SAPA 18 R 0 0 93 14 SAPA 14 R 0 0 95 11 SAPA 11 R 0 0 96 10 SAPA 10 R 0 0 97 16 SAPA 16 K 0 0 1:1 1 99 16 SAPA 16 R 0 0 100 16 SAPA 16 R 0 0 101 16 SAPA 16 R 0 0 102 16 SAPA 16 R 0 0 103 15 SAPA 15 R 0 0 104 12 SAPA 12 R 0 0 105 17 QULA 17 R 2:1 34 106 14,12 QULA 26 R 2:1 26 107 20 PIEL 20 R 2:1 40 108 9 SAPA 9 R 0 0 109 12 SAPA 12 R 0 0 110 12 SAPA 12 R 0 0 111 11 SAPA 11 R 0 0 112 16 PIEL 16 R 2:1 32 113 16 QULA 16 R 2:1 32 114 12 PIEL 12 R 2:1 24 115 16 SAPA 16 K 0 0 1:1 1 116 10 SAPA 10 K 0 0 1:1 1 117 17 SAPA 17 K 0 0 1:1 1 118 18 PIEL 18 R 2:1 36 119 10,9 QULA 19 R 2:1 38 120 16 QULA 16 R 2:1 32 121 12 SAPA 12 R 0 0 124 12 SAPA 12 R 0 0 127 9 SAPA 9 R 0 0 128 14 SAPA 14 R 0 0 130 12 QULA 12 K 1:2 24 131 10 SAPA 10 R 0 0 132 13 SAPA 13 K 0 0 1:1 1 133 13 SAPA 13 K 0 0 1:1 1 134 16 SAPA 16 R 0 0 135 19 SAPA 19 R 0 0 136 13 QULA 13 R 2:1 26 137 16 SAPA 16 R 0 0 138 14 PIEL 14 R 2:1 28 139 12 QULA 12 R 2:1 24 140 14 QULA 14 R 2:1 28 141 12 QULA 12 K 1:2 24 142 QULA 8 R 2:1 16 143 18 PIEL 18 R 2:1 36 8142 Tree Number DBH (Inches)Species*DBH TOTAL (Inches) Remove (R) or Keep (K)Replacement Ratio Replacement Inches Preserved Ratio Preservation Credits (Inches) Preservation Credits (Palms) TOTAL OAKS 22 TOTAL OAKS TBR 20 TOTAL PINES 23 TOTAL PINES TBR 23 TOTAL PALMS 76 TOTAL PALMS TBR 70 TOTALS 121 1,423 TOTAL MITIGATION REQUIRED 1,375 QTY AMOUNT TOTAL MITIGATION PAYMENT - OAK 389 (INCHES)$77,800.00 TOTAL MITIGATION PAYMENT - PINE 370 (INCHES)$74,000.00 TOTAL MITIGATION PAYMENT - PALM 70 (PALMS)$14,000.00 SUBTOTAL:$165,800.00 QTY AMOUNT SUMMARY OF PRESERVED - OAKS 48 (INCHES)-$9,600.00 SUMMARY OF PRESERVED - PINES 0 (INCHES)- SUMMARY OF PRESERVED - PALMS 6 (PALMS)-$1,200.00 SUBTOTAL:-$10,800.00 QTY AMOUNT SUMMARY OF PROPOSED 472.5 (INCHES)-$94,500.00 SUBTOTAL:-$94,500.00 SUMMARY OF OWED TOTAL:$60,500.00 PR O J E C T : NE W O ' R E I L L Y A U T O P A R T S S T O R E TU R N P I K E F E E D E R R D . FO R T P I E R C E , F L # 4 CO R P O R A T E O F F I C E S 23 3 S O U T H P A T T E R S O N SP R I N G F I E L D , M I S S O U R I 6 5 8 0 2 (4 1 7 ) 8 6 2 - 2 6 7 4 T E L E P H O N E AU T O P A R T S REVISION DATE: DATE:06/16/2023 COMM # 4712 17 3 6 E a s t S u n s h i n e , S u i t e 4 1 7 Sp r i n g f i e l d , M i s s o u r i 6 5 8 0 4 Fa x : 4 1 7 . 8 6 2 . 3 2 6 5 e- m a i l : a r c h i t e c t @ e s t e r l y s c h n e i d e r . c o m 41 7 . 8 6 2 . 0 5 5 8 CRA I G A. SCH N E I D E R , AI A AR C H I T E C T TR E E M I T I G A T I O N L2 OF 6 *SPECIES: Cabbage/Sabal Palm, Sabal palmetto (SAPA) Slash Pine, Pinus elliottii (PIEL) Live Oak, Quercus virginiana (QUVI) Laurel Oak, Quercus laurifolia (QULA) 01/26/2024 05/21/2024 Page 345 of 428 P K W Y ( 7 0 ' W I D E ) P A L O M A R ABACA DR TRASH PAD TURNPIKE FEEDER RD /HWY 713 P K W Y ( 7 0 ' W I D E ) P A L O M A R ABACA DR DEL E O N A V E ( 7 0 ' W I D E ) O'Reilly Auto Parts 86'-4" X 86'-4" SQ.FT. = 7,627 SR.FLOOR ELEVATION: 000.00' PROPOSED DETENTION POND MFG.: LEEMCO FITTINGS (MODEL: LBT-XX-SS) GENERAL NOTES: 1.IRRIGATION SYSTEM DESIGN BASED ON 30 GPM AND 75 PSI. 2.IRRIGATION DESIGN IS FROM THE POINT OF CONNECTION (POC) ONLY. THE DESIGN IS BASED ON GALLONS PER MINUTE (GPM) AND POUNDS PER SQUARE INCH (PSI) AS FURNISHED BY OTHERS. 3.IRRIGATION CONTRACTOR TO VERIFY POINT OF CONNECTION IN THE FIELD AND CONFIRM MINIMUM DISCHARGE REQUIRED AT POINT OF CONNECTION AS REQUIRED BY PROPOSED IRRIGATION EQUIPMENT PRIOR TO INSTALLATION. CONTACT OWNER'S REPRESENTATIVE WITH ANY DISCREPANCIES IMMEDIATELY BEFORE INSTALLATION. 4.THE PRESSURE REQUIREMENT AT THE POINT OF CONNECTION IS BASED ON NO MORE THAN 5 FEET OF ELEVATION CHANGE IN THE AREAS OF IRRIGATION. 5.CONTRACTOR TO USE CONTINUOUS RUNS FOR ALL PROPOSED CONTROL WIRES. IF NECESSARY, LOCATE ALL WIRE SPLICES IN VALVE BOX. BUNDLE WIRES IN VALVE BOX WITH MINIMUM 24" OF EXCESS CABLE PER BUNDLE. ALL SPLICES MUST BE WATERPROOF WITH 3M DBY/DBR-6 CONNECTORS. 6.PIPE LOCATIONS ARE DIAGRAMMATIC. VALVES AND MAINLINE SHOWN IN PAVED AREAS ARE FOR GRAPHIC CLARITY ONLY. 7.ALL MATERIAL USED SHALL BE INSTALLED AS PER PLAN AND AS PER MANUFACTURER'S SPECIFICATIONS. ALL DEVIATIONS FROM DRAWINGS OR MATERIALS SHALL BE APPROVED BY THE OWNER OR LANDSCAPE ARCHITECT. 8.CONTRACTOR TO PROVIDE ANY STAKING NECESSARY FOR PROPERTY LINES, EASEMENT LINES, ETC. TO INSTALL PLANTING AND IRRIGATION AS PER PLANS. 9.LOCATE VALVES AND VALVE BOXES IN SHRUB BED WHENEVER POSSIBLE. IF NECESSARY TO LOCATE IN LAWN, LOCATE A MINIMUM OF 36" AWAY FROM PLANTER BED EDGE. 10.SEE DETAIL SHEET L301 & L302 FOR FURTHER IRRIGATION NOTES & DETAILS 0 10 20 40 SCALE: 1"=20'-0" PR O J E C T : NE W O ' R E I L L Y A U T O P A R T S S T O R E TU R N P I K E F E E D E R R D . FO R T P I E R C E , F L # 4 CO R P O R A T E O F F I C E S 23 3 S O U T H P A T T E R S O N SP R I N G F I E L D , M I S S O U R I 6 5 8 0 2 (4 1 7 ) 8 6 2 - 2 6 7 4 T E L E P H O N E AU T O P A R T S REVISION DATE: DATE:06/16/2023 COMM # 4712 17 3 6 E a s t S u n s h i n e , S u i t e 4 1 7 Sp r i n g f i e l d , M i s s o u r i 6 5 8 0 4 Fa x : 4 1 7 . 8 6 2 . 3 2 6 5 e- m a i l : a r c h i t e c t @ e s t e r l y s c h n e i d e r . c o m 41 7 . 8 6 2 . 0 5 5 8 CRA I G A. SCH N E I D E R , AI A AR C H I T E C T 8 5 4 6 7 2 1 PROPERTY LINE RIGHT-OF-WAY SYMBOLS LEGEND REFER TO SURVEY FOR EXISTING CONDITION SYMBOLS LEGEND NEW BUILDING CONSTRUCTION AREA OF CONCRETE NEW POLE SIGN LOCATION IR R I G A T I O N P L A N 4 2 L3 OF 6 KEY NOTES: ALL PROPOSED LAWN AREAS THAT HAVE NOT BEEN HATCHED WITH DRIP AREA HATCHING AND DO NOT CONTAIN EXISTING PLANT MATERIAL WILL BE IRRIGATED WITH SPRAY HEAD IRRIGATION OR ROTORS UNLESS OTHERWISE NOTED (TYP.). POND AREAS TO BE ZONED SEPARATELY. PLANTER BED IRRIGATION COVERAGE (TYP. OF HATCHED AREAS). ALL PROPOSED PLANTINGS SHALL RECEIVE DRIP IRRIGATION POINT OF CONNECTION IS A SEPARATE WATER METER WITH A BACKFLOW PREVENTER. REFER TO CIVIL SET FOR FURTHER INFORMATION 2" IRRIGATION MAINLINE (TYP.) - SOLVENT WELD PVC - ASTM D2241 - CLASS 200 - SDR 21 CONTRACTOR WILL BE REQUIRED TO LOOP THE IRRIGATION MAINLINE TO REDUCE PRESSURE LOSS IF NEEDED NOTE: MAINLINE LAYOUT IS DIAGRAMMATIC. VALVES AND MAINLINE SHOWN IN PAVED AREAS ARE FOR GRAPHIC CLARITY ONLY. ALL VALVES AND MAINLINE SHALL BE INSTALLED WITHIN LANDSCAPE AREAS. CONTRACTOR SHALL NOT ROUTE MAINLINE NEAR EXISTING OR PROPOSED TREES, OR UTILITY LINES. REFER TO CIVIL SET FOR MORE INFORMATION PRIOR TO INSTALLATION. UNDERPAVEMENT SLEEVING (TYP.) - SCHEDULE 40 PIPE: 4" DIAMETER UNLESS OTHERWISE INDICATED. TO BE INSTALLED BY LANDSCAPE CONTRACTOR AT DEPTH AS PER LOCAL CODE. AUTOMATIC CONTROLLER: MOUNT CONTROLLER ON BACK OF WALL IF ACCEPTABLE WITH OWNER POTENTIAL LOCATION FOR WIRELESS MINI WEATHER STATION/ RAIN SENSOR: MOUNT RAIN SENSOR ON TOP OF BUILDING IF ACCEPTABLE WITH OWNER. ENSURE SENSOR IS OUT OF EXISTING AND FUTURE DRIPLINES OF TREES STAINLESS STEEL BALL VALVE (TYP.) - SIZE PER LINE SIZE MFG.: LEEMCO FITTINGS (MODEL: LBT-XX-SS) CONTRACTOR TO HAND-WATER TREE MIX AREA UNTIL ESTABLISHMENT 1 2 3 4 5 6 7 8 9 2 5 5 2 2 8 2 2 2 2 9 9 2 01/26/2024 2 3 05/21/2024 Page 346 of 428 Page 347 of 428 Tree Number DBH (Inches)Species*DBH TOTAL (Inches) Remove (R) or Keep (K)Replacement Ratio Replacement Inches Preserved Ratio Preservation Credits (Inches) Preservation Credits (Palms) 1 20 SAPA 20 R 0 0 2 14 SAPA 14 R 0 0 3 15 SAPA 15 R 0 0 4 12 SAPA 12 R 0 0 5 18 SAPA 18 R 0 0 6 15 SAPA 15 R 0 0 7 13 SAPA 13 R 0 0 8 16 SAPA 16 R 0 0 9 33 QULA 33 R 2:1 66 10 13 SAPA 13 R 0 0 11 18 QULA 18 R 2:1 36 12 18 QULA 18 R 2:1 36 13 15,10 QUVI 25 R 2:1 50 14 15 SAPA 15 R 0 0 15 14 PIEL 14 R 2:1 28 16 23 QUVI 23 R 2:1 46 17 12 PIEL 12 R 2:1 24 18 10,8 PIEL 18 R 2:1 36 19 13 PIEL 13 R 2:1 26 20 14 SAPA 14 R 0 0 21 13 SAPA 13 R 0 0 22 13 SAPA 13 R 0 0 23 13 SAPA 13 R 0 0 24 19 PIEL 19 R 2:1 38 25 11 SAPA 11 R 0 0 26 11 SAPA 11 R 0 0 27 13 SAPA 13 R 0 0 28 21 PIEL 21 R 2:1 42 29 13 SAPA 13 R 0 0 30 13 SAPA 13 R 0 0 34 12 PIEL 12 R 2:1 24 35 17 SAPA 17 R 0 0 36 11 SAPA 11 R 0 0 37 11 SAPA 11 R 0 0 38 15 SAPA 15 R 0 0 39 17 PIEL 17 R 2:1 34 40 15 SAPA 15 R 0 0 46 15 SAPA 15 R 0 0 47 12 PIEL 12 R 2:1 12 48 17 SAPA 17 R 0 0 49 13 PIEL 13 R 2:1 26 50 26 QULA 26 R 2:1 52 52 10 SAPA 10 R 0 0 53 13 SAPA 13 R 0 0 54 18 SAPA 18 R 0 0 55 14 QULA 14 R 2:1 28 56 15 SAPA 15 R 0 0 57 14 QULA 14 R 2:1 28 58 16 SAPA 16 R 0 0 59 10 SAPA 10 R 0 0 60 13 SAPA 13 R 0 0 61 12 SAPA 12 R 0 0 62 23 PIEL 23 R 2:1 46 63 17 PIEL 17 R 2:1 34 64 14 SAPA 14 R 0 0 66 12 SAPA 12 R 0 0 67 16 SAPA 16 R 0 0 68 11 SAPA 11 R 0 0 69 18 PIEL 18 R 2:1 36 70 18 PIEL 18 R 2:1 36 71 18 SAPA 18 R 0 0 72 15 SAPA 15 R 0 0 73 11 SAPA 11 R 0 0 75 13 SAPA 13 R 0 0 76 13 SAPA 13 R 0 0 77 15 PIEL 15 R 2:1 30 78 9 SAPA 9 R 0 0 79 12 SAPA 12 R 0 0 80 12,12,9 QULA 33 R 2:1 33 81 14 QULA 14 R 2:1 28 82 9,9 QULA 18 R 2:1 36 83 15 SAPA 15 R 0 0 84 17 PIEL 17 R 2:1 34 89 13 SAPA 13 R 0 0 90 10 SAPA 10 R 0 0 91 13 PIEL 13 R 2:1 26 92 18 SAPA 18 R 0 0 93 14 SAPA 14 R 0 0 95 11 SAPA 11 R 0 0 96 10 SAPA 10 R 0 0 97 16 SAPA 16 K 0 0 1:1 1 99 16 SAPA 16 R 0 0 100 16 SAPA 16 R 0 0 101 16 SAPA 16 R 0 0 102 16 SAPA 16 R 0 0 103 15 SAPA 15 R 0 0 104 12 SAPA 12 R 0 0 105 17 QULA 17 R 2:1 34 106 14,12 QULA 26 R 2:1 26 107 20 PIEL 20 R 2:1 40 108 9 SAPA 9 R 0 0 109 12 SAPA 12 R 0 0 110 12 SAPA 12 R 0 0 111 11 SAPA 11 R 0 0 112 16 PIEL 16 R 2:1 32 113 16 QULA 16 R 2:1 32 114 12 PIEL 12 R 2:1 24 115 16 SAPA 16 K 0 0 1:1 1 116 10 SAPA 10 K 0 0 1:1 1 117 17 SAPA 17 K 0 0 1:1 1 118 18 PIEL 18 R 2:1 36 119 10,9 QULA 19 R 2:1 38 120 16 QULA 16 R 2:1 32 121 12 SAPA 12 R 0 0 124 12 SAPA 12 R 0 0 127 9 SAPA 9 R 0 0 128 14 SAPA 14 R 0 0 130 12 QULA 12 K 1:2 24 131 10 SAPA 10 R 0 0 132 13 SAPA 13 K 0 0 1:1 1 133 13 SAPA 13 K 0 0 1:1 1 134 16 SAPA 16 R 0 0 135 19 SAPA 19 R 0 0 136 13 QULA 13 R 2:1 26 137 16 SAPA 16 R 0 0 138 14 PIEL 14 R 2:1 28 139 12 QULA 12 R 2:1 24 140 14 QULA 14 R 2:1 28 141 12 QULA 12 K 1:2 24 142 QULA 8 R 2:1 16 143 18 PIEL 18 R 2:1 36 8142 Tree Number DBH (Inches)Species*DBH TOTAL (Inches) Remove (R) or Keep (K)Replacement Ratio Replacement Inches Preserved Ratio Preservation Credits (Inches) Preservation Credits (Palms) TOTAL OAKS 22 TOTAL OAKS TBR 20 TOTAL PINES 23 TOTAL PINES TBR 23 TOTAL PALMS 76 TOTAL PALMS TBR 70 TOTALS 121 1,423 TOTAL MITIGATION REQUIRED 1,375 QTY AMOUNT TOTAL MITIGATION PAYMENT - OAK 389 (INCHES)$77,800.00 TOTAL MITIGATION PAYMENT - PINE 370 (INCHES)$74,000.00 TOTAL MITIGATION PAYMENT - PALM 70 (PALMS)$14,000.00 SUBTOTAL:$165,800.00 QTY AMOUNT SUMMARY OF PRESERVED - OAKS 48 (INCHES)-$9,600.00 SUMMARY OF PRESERVED - PINES 0 (INCHES)- SUMMARY OF PRESERVED - PALMS 6 (PALMS)-$1,200.00 SUBTOTAL:-$10,800.00 QTY AMOUNT SUMMARY OF PROPOSED 472.5 (INCHES)-$94,500.00 SUBTOTAL:-$94,500.00 SUMMARY OF OWED TOTAL:$60,500.00 PR O J E C T : NE W O ' R E I L L Y A U T O P A R T S S T O R E TU R N P I K E F E E D E R R D . FO R T P I E R C E , F L # 4 CO R P O R A T E O F F I C E S 23 3 S O U T H P A T T E R S O N SP R I N G F I E L D , M I S S O U R I 6 5 8 0 2 (4 1 7 ) 8 6 2 - 2 6 7 4 T E L E P H O N E AU T O P A R T S REVISION DATE: DATE:06/16/2023 COMM # 4712 17 3 6 E a s t S u n s h i n e , S u i t e 4 1 7 Sp r i n g f i e l d , M i s s o u r i 6 5 8 0 4 Fa x : 4 1 7 . 8 6 2 . 3 2 6 5 e- m a i l : a r c h i t e c t @ e s t e r l y s c h n e i d e r . c o m 41 7 . 8 6 2 . 0 5 5 8 CRA I G A. SCH N E I D E R , AI A AR C H I T E C T TR E E M I T I G A T I O N L2 OF 6 *SPECIES: Cabbage/Sabal Palm, Sabal palmetto (SAPA) Slash Pine, Pinus elliottii (PIEL) Live Oak, Quercus virginiana (QUVI) Laurel Oak, Quercus laurifolia (QULA) 01/26/2024 05/21/2024 Page 348 of 428 O’REILLY AUTO PARTS St. Lucie County, FL TRAFFIC IMPACT STATEMENT PREPARED FOR: O’Reilly Automotive Stores, Inc. 233 South Patterson Avenue Springfield, Missouri 65802 JOB NO. 23-128 DATE: 10/27/2023 Engineer’s Name, Professional Engineer, State of Florida, License No. ------ This item has been digitally signed and sealed by Engineer’s Name, P.E., on MM/DD/YY. Printed Copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. 2581 Metrocentre Blvd. West, Ste 3 | West Palm Beach, FL 33407 561.478.7848 | simmonsandwhite.com | Certificate of Authorization #3452 Page 349 of 428 TABLE OF CONTENTS PAGE 4 1.0 Site Data 2.0 Traffic Generation 3.0 Traffic Analysis PAGE 5 4.0 Driveway Volumes 5.0 Conclusion Page 350 of 428 1.0 SITE DATA The subject parcel is generally located on the southeast side of Turnpike Feeder Road approximately 0.5 miles north of Indrio Road in St. Lucie County, FL. The proposed plan of development on the currently unimproved parcel is to consist of 7472 SF automobile parts store with an estimated build out year of 2028. Site access is proposed via a full access driveway connection to Turnpike Feeder Road and a full access driveway connection to Palomer Parkway. For additional information on site layout, please refer to the Site Plan prepared by OWN Engineering. The site location map is shown in Figure 1 attached to this report. 2.0 TRAFFIC GENERATION The proposed traffic generation for the site has been calculated in accordance with the rates provided in the ITE Trip Generation Manual, 11th Edition as shown on Table 1, Table 2, and Table 3 attached with this report. Table 1 shows the daily traffic generation associated with the existing use. Tables 2 and 3 show the A.M. and P.M. peak hour traffic generation, respectively. The traffic generation associated with the proposed development may be summarized as follows: Proposed Development Weekday Daily Traffic Generation = 233 tpd A.M. Peak Hour Traffic Generation = 11 pht (6 In/5 Out) P.M. Peak Hour Traffic Generation = 21 pht (10 In/11 Out) 3.0 TRAFFIC ANALYSIS The project trips were distributed on the surrounding roadway network as shown in the Trip Distribution figure. Tables 5 and 6 document the peak hour project impact on each of the surrounding roadways. As shown in Tables 5 and 6, the project will not have a significant impact (more than 1%) to the surrounding roadway network. Turnpike Feeder Road was analyzed as if it had a significant impact to be conservative as shown in Tables 7 and 8. Tables 7 and 8 document the roadway link analysis for the roadway segments with a project impact greater than 1% of the LOS D thresholds. Existing roadway volumes were obtained from the St. Lucie TPO Traffic Counts and Level of Service Report (2019, 2023) are attached to this report. To determine the background growth rate, the 4-year daily traffic volumes were reviewed for the subject roadway. The roadways showed minimal growth and therefore a nominal 1% growth rate was used as shown in Table 4. In Tables 7 and 8, all subject roadways meet applicable LOS thresholds. 4.0 DRIVEWAY VOLUMES The AM and PM peak hour volumes at the project entrances for the overall development with no reduction for pass by credits are shown in Tables 2 and 3 and may be summarized as follows: Page 351 of 428 4.0 DRIVEWAY VOLUMES (CONTINUED) Directional Distribution (Trips IN/OUT) AM = 10 / 9 PM = 18 / 19 The Turning Movement figure presents the AM and PM peak turning movement volume assignments at the project driveway based on the directional distributions. As previously mentioned, access is proposed via a full access driveway connections to Turnpike Feeder Road and a full access driveway connection Palomer Parkway. Based on the low project driveway trips, no additional turn lanes are warranted or recommended. 5.0 CONCLUSION The attached tables document the daily, A.M. peak hour and P.M. peak hour traffic generation for the proposed development. The proposed development will generate 233 daily trips, 11 A.M. peak hour trips, and 21 P.M. peak hour trips. Based on the findings of this report, the proposed development will meet Level of Service standards on the surrounding roadway network. JG: x:\Documents\Traffic Drainage&Structural/tis.23128 Page 352 of 428 Figure 1 – Site Location Map O’Reilly Auto parts Project # 23-128 N SITE Indrio Rd Kings Hwy Page 353 of 428 O'REILLY AUTO PARTS Page 354 of 428 O'REILLY AUTO PARTS Page 355 of 428 O'REILLY AUTOPARTS 10/19/23 TABLE 1 - Daily Traffic Generation ITELanduseCode Rate/Equation In Out %%Trips Automobile Parts Sales 843 7,472 S.F.54.57 43%175 Grand Totals:0.0%43%175 TABLE 2 - AM Peak Hour Traffic Generation ITELanduseCode Rate/Equation In Out In Out Total %In Out Total In Out Total %Trips In Out Total Automobile Parts Sales 843 7,472 S.F.2.51 0.55 0.45 10 9 19 0.0%0 0 0 10 9 19 43%8 6 5 11 Grand Totals:10 9 19 0.0%0 0 0 10 9 19 43%8 6 5 11 TABLE 3 - PM Peak Hour Traffic Generation ITELanduseCode Rate/Equation In Out In Out Total %In Out Total In Out Total %Trips In Out Total Automobile Parts Sales 843 7,472 S.F.4.9 0.48 0.52 18 19 37 0.0%0 0 0 18 19 37 43%16 10 11 21 Grand Totals:18 19 37 0.0%0 0 0 18 19 37 43%16 10 11 21 PROPOSED DEVELOPMENT Dir Split Internalization Pass-byIntensityGross Trips Total External Trips Net Trips 408 0 408 233 408 0 408 233 Net TripsIntensityDir Split Gross Trips Internalization External Trips Pass-by Net TripsIntensityDir Split Gross Trips Internalization External Trips Pass-by Page 356 of 428 O'REILLY AUTOPARTS 10/19/23 2019 PEAK 2023 PEAK SEASON DAILY SEASON DAILY IND.STATION ROADWAY FROM TO TRAFFIC TRAFFIC (%) KINGS HWY ST LUCIE BLVD INDRIO ROAD 14,900 13,787 -1.92% TURNPIKE FEEDER ROAD INDRIO ROAD SITE / PALOMER PKWY 13,200 13,204 0.01%TURNPIKE FEEDER ROAD SITE / PALOMER PKWY US 1 11,200 11,335 0.30%US 1 25 TH STREET INDRIO ROAD 24,500 19,097 -6.04%US 1 INDRIO ROAD TURNPIKE FEEDER ROAD 24,500 24,070 -0.44%US 1 TURNPIKE FEEDER ROAD INDIAN RIVER C.L. 24,500 24,070 -0.44% INDRIO ROAD SEMINOLE ROAD KINGS HWY 11,200 10,743 -1.04%*INDRIO ROAD KINGS HWY US 1 6,600 6,500 -0.51%PALOMER PKWY KINGS HWY SITE N/A N/A N/APALOMER PKWY SITE / TURNPIKE FEEDER RD EASTWOOD DRIVE N/A N/A N/A NOTE: * 2020 COUNTS WERE USED INSTEAD OF 2019 ∑ =130,600 122,806 -1.53% -1.5% . TABLE 4 AREA WIDE GROWTH RATE CALCULATION AREA WIDE GROWTH RATE = X:\Documents\PROJECTS\2023\23-128 O'Reilly Automotive\Excel\23128 - Traffic Report Calcs AL Page 357 of 428 O'REILLY AUTOPARTS 10/19/23 65 PEAK HOUR TOTAL PROJECT PROJECT EXISTING LOS D PROJECT PROJECT ROADWAY FROM TO DIRECTION DISTRIBUTION TRIPS LANES CLASS STANDARD IMPACT SIGNIFICANT NB 18%1 2 I 880 0.12%NOSB18%1 2 I 880 0.10%NO NB 35%2 2 I 880 0.24%NOSB35%2 2 I 880 0.20%NONB55%3 2 I 880 0.38%NO SB 55%3 2 I 880 0.31%NO NB 10%1 4 I 1960 0.03%NOSB10%1 4 I 1960 0.03%NONB0%0 4 I 1960 0.00%NOSB0%0 4 I 1960 0.00%NONB50%3 4 I 1960 0.15%NOSB50%3 4 I 1960 0.13%NO EB 5%0 2 II 810 0.04%NOWB5%0 2 II 810 0.03%NOEB5%0 2 II 810 0.04%NOWB5%0 2 II 810 0.03%NO EB 7%0 2 I 880 0.05%NOWB7%0 2 I 880 0.04%NOEB10%1 2 I 880 0.07%NO WB 10%1 2 I 880 0.06%NO NOTE: FOR THE PURPOSE OF THIS TRAFFIC STUDY TURNPIKE FEEDER ROAD IS BEING TESTED AS SIGNIFICANT TABLE 5PROJECT SIGNIFICANCE CALCULATIONAM PEAK HOUR ST. LUCIE BLVD INDRIO ROAD TURNPIKE FEEDER ROAD US 1 TURNPIKE FEEDER ROAD INDIAN RIVER C. L. PALOMER PKWY KING HWY SITE / TURNPIKE FEEDER INDRIO ROAD KINGS HWY US 1 TOTAL AM PEAK HOUR PROJECT TRIPS (OUT) =TOTAL AM PEAK HOUR PROJECT TRIPS (IN) = KING HWY TURNPIKE FEEDER ROAD INDRIO ROAD SITE / PALOMER PKWY INDRIO ROAD 25TH STREET US 1 US 1 SITE / PALOMER PKWYTURNPIKE FEEDER ROAD US 1 INDRIO ROAD PALOMER PKWY SITE / TURNPIKE FEEDER EASTWOOD DRIVE INDRIO ROAD SEMINOLE ROAD KINGS HWY X:\Documents\PROJECTS\2023\23-128 O'Reilly Automotive\Excel\23128 - Traffic Report CalcsBK Page 358 of 428 O'REILLY AUTOPARTS 10/19/23 10 11 PEAK HOUR TOTAL PROJECT PROJECT EXISTING LOS D PROJECT PROJECT ROADWAY FROM TO DIRECTION DISTRIBUTION TRIPS LANES CLASS STANDARD IMPACT SIGNIFICANT NB 18%2 2 I 880 0.20%NOSB18%2 2 I 880 0.23%NO NB 35%4 2 I 880 0.40%NOSB35%4 2 I 880 0.44%NONB55%6 2 I 880 0.63%NOSB55%6 2 I 880 0.69%NO NB 10%1 4 I 1960 0.05%NOSB10%1 4 I 1960 0.06%NONB0%0 4 I 1960 0.00%NOSB0%0 4 I 1960 0.00%NONB50%5 4 I 1960 0.26%NOSB50%6 4 I 1960 0.28%NO EB 5%1 2 II 810 0.06%NOWB5%1 2 II 810 0.07%NOEB5%1 2 II 810 0.06%NOWB5%1 2 II 810 0.07%NO EB 7%1 2 I 880 0.08%NOWB7%1 2 I 880 0.09%NOEB10%1 2 I 880 0.11%NOWB10%1 2 I 880 0.13%NOINDRIO ROAD KINGS HWY US 1 NOTE: FOR THE PURPOSE OF THIS TRAFFIC STUDY TURNPIKE FEEDER ROAD IS BEING TESTED AS SIGNIFICANT PALOMER PKWY SITE / TURNPIKE FEEDER EASTWOOD DRIVE INDRIO ROAD SEMINOLE ROAD KINGS HWY KING HWY TOTAL PM PEAK HOUR PROJECT TRIPS (OUT) = TOTAL PM PEAK HOUR PROJECT TRIPS (IN) = TABLE 6 PROJECT SIGNIFICANCE CALCULATIONPM PEAK HOUR ST. LUCIE BLVD INDRIO ROAD TURNPIKE FEEDER ROAD SITE / PALOMER PKWY US 1 TURNPIKE FEEDER ROAD INDRIO ROAD SITE / PALOMER PKWY US 1 INDRIO ROAD TURNPIKE FEEDER ROAD US 1 25TH STREET INDRIO ROAD PALOMER PKWY KING HWY SITE / TURNPIKE FEEDER US 1 TURNPIKE FEEDER ROAD INDIAN RIVER C. L. X:\Documents\PROJECTS\2023\23-128 O'Reilly Automotive\Excel\23128 - Traffic Report CalcsBK Page 359 of 428 O'REILLY AUTOPARTS 10/19/23 651.0% PEAK HOUR 2023 2028 2028PROJECTPROJECTEXISTING BACKGROUND TOTAL EXISTING LOS D MEETSROADWAYFROMTODISTRIBUTIONTRIPSVOLUMESGROWTHVOLUMELANESCLASSSTANDARDLOS? 2028 BUILD OUTTOTAL AM PEAK HOUR PROJECT TRIPS (IN) = TABLE 7ROADWAY SEGMENT ANALYSIS - AM PEAK HOUR TURNPIKE FEEDER ROAD SITE / PALOMER PKWY US 1 TOTAL AM PEAK HOUR PROJECT TRIPS (OUT) =BACKGROUND GROWTH = TURNPIKE FEEDER ROAD INDRIO ROAD SITE / PALOMER PKWY 35%2 355% 533 644 27 33 880 YES 880 YES 562 680 2 2 I I X:\Documents\PROJECTS\2023\23-128 O'Reilly Automotive\Excel\23128 - Traffic Report CalcsAL Page 360 of 428 O'REILLY AUTOPARTS 10/19/23 10111.0% PEAK HOUR 2023 2028 2028PROJECTPROJECTEXISTING BACKGROUND TOTAL EXISTING LOS D MEETSROADWAYFROMTODISTRIBUTIONTRIPSVOLUMESGROWTHVOLUMELANESCLASSSTANDARDLOS? TURNPIKE FEEDER ROAD SITE / PALOMER PKWY US 1 2028 BUILD OUTTOTAL PM PEAK HOUR PROJECT TRIPS (IN) = TABLE 8ROADWAY SEGMENT ANALYSIS - PM PEAK HOUR TOTAL PM PEAK HOUR PROJECT TRIPS (OUT) =BACKGROUND GROWTH = TURNPIKE FEEDER ROAD INDRIO ROAD SITE / PALOMER PKWY 35%I 55% 4 6 533 644 33 27 564 682 2 2 I 880 880 YES YES X:\Documents\PROJECTS\2023\23-128 O'Reilly Automotive\Excel\23128 - Traffic Report CalcsAL Page 361 of 428 Roadway Name Location AADT Volume LOS V/C PM Pk Hr Pk Dir Pk Hr Service Capacity AM Pk Hr Pk Dir V/C LOS Volume STATION ID Last Count Year Traffic Counts and Level of Service Report Fall/Winter 2019/2020 57,000 ORANGE AVE to INDRIO RDI-95 7,320 2,742 941905 B 0.609 2,524 B 0.561 2019 6,800 CITRUS AVE to ORANGE AVEINDIAN RIVER DR 750 405 945029 D 0.540 463 D 0.617 2019 5,600 ORANGE AVE to AVENUE AINDIAN RIVER DR 750 327 940003 C 0.884 318 C 0.859 2019 7,400 AVENUE D to SEAWAY DRINDIAN RIVER DR 790 433 940004 D 0.548 509 D 0.644 2019 7,400 AVENUE A to AVENUE DINDIAN RIVER DR 540 433 940004 D 0.802 509 D 0.943 2019 1,850 PRIVATE RD to I-95 W RAMPINDRIO RD 1,080 135 940128 B 0.329 146 B 0.356 2019 1,850 I-95 W RAMP to I-95 E RAMPINDRIO RD 3,240 135 940128 B 0.075 146 B 0.081 2019 10,200 I-95 E RAMP to KOBLEGARD RDINDRIO RD 3,240 583 940038 B 0.322 613 B 0.339 2019 10,200 KOBLEGARD RD to JOHNSTON RDINDRIO RD 700 583 940038 C 0.883 613 C 0.929 2019 10,200 JOHNSTON RD to EMERSON AVEINDRIO RD 880 583 940038 C 0.702 613 C 0.739 2019 11,200 EMERSON RD to SEMINOLE RDINDRIO RD 920 675 940281 C 0.776 568 C 0.653 2019 11,200 SEMINOLE RD to KINGS HWYINDRIO RD 790 675 940281 D 0.854 568 D 0.719 2019 6,600 KINGS HWY to SLASH PINE TRLINDRIO RD 790 422 114 D 0.534 413 D 0.523 2020 6,600 SLASH PINE TRL to US 1INDRIO RD 920 422 114 C 0.485 413 C 0.475 2020 917 US 1 to OLD DIXIE HWYINDRIO RD 750 64 672 C 0.173 86 C 0.232 2016 4,600 US 1 to LENNARD RDJENNINGS RD 2,100 304 673 C 0.151 248 C 0.123 2016 10,500 EDWARDS RD to OKEECHOBEE RDJENKINS RD 880 549 133 C 0.661 553 C 0.666 2020 10,500 OKEECHOBEE RD to GRAHAM RDJENKINS RD 920 593 131 C 0.682 569 C 0.654 2020 10,500 GRAHAM RD to PETERSON RDJENKINS RD 630 593 131 C 0.988 569 C 0.948 2020 10,500 PETERSON RD to ORANGE AVEJENKINS RD 920 593 131 C 0.682 569 C 0.654 2020 2,600 ANGLE RD to L20JOHNSTON RD 1,070 176 674 B 0.463 171 B 0.450 2016 2,233 L20 to MEADOWOOD DRJOHNSTON RD 1,070 142 675 B 0.374 138 B 0.363 2017 2,233 MEADOWOOD DR to OLD JOHNSTON RDJOHNSTON RD 1,070 142 675 B 0.374 138 B 0.363 2017 2,233 OLD JOHNSTON RD to INDRIO RDJOHNSTON RD 1,070 142 675 B 0.374 138 B 0.363 2017 9,600 INDRIO RD to RUSSOS RDJOHNSTON RD 1,070 544 135 C 0.716 545 C 0.717 2020 9 * Volumes shown were adjusted using FDOT Seasonal Factors * AADT = Annual Average Daily Traffic (volumes for both directions where applicable) * Counts with an ID format of 6 digits have data extracted from FDOT count stations. * Note: A six digit number in the "STATION ID" column identifies segment counted by FDOT Page 362 of 428 Roadway Name Location AADT Volume LOS V/C PM Pk Hr Pk Dir Pk Hr Service Capacity AM Pk Hr Pk Dir V/C LOS Volume STATION ID Last Count Year Traffic Counts and Level of Service Report Fall/Winter 2019/2020 9,600 RUSSOS RD to INDIAN RIVER C.L.JOHNSTON RD 1,070 544 135 C 0.716 545 C 0.717 2020 2,432 53RD ST to 25TH STJUANITA AVE 750 157 122 C 0.424 143 C 0.386 2017 3,321 25TH ST to US 1JUANITA AVE 750 185 120 C 0.500 182 C 0.492 2017 2,885 ANGLE RD to JUANITA AVEKEEN RD 630 174 129 C 0.290 203 C 0.338 2019 2,885 JUANITA AVE to ST LUCIE BLVDKEEN RD 630 174 129 C 0.290 203 C 0.338 2019 7,600 OKEECHOBEE RD to CROSSROADS PKWYKINGS HWY 830 333 940757 C 0.401 341 C 0.411 2019 7,600 CROSSROADS PKWY to GRAHAM RDKINGS HWY 660 333 940757 C 0.505 341 C 0.517 2019 7,000 GRAHAM RD to PICOS RDKINGS HWY 660 345 940076 C 0.523 331 C 0.502 2019 7,000 PICOS RD to ORANGE AVEKINGS HWY 830 345 940076 C 0.416 331 C 0.399 2019 13,900 ORANGE AVE to ANGLE RDKINGS HWY 870 732 940077 C 0.841 737 C 0.847 2019 13,100 ANGLE RD to ST LUCIE BLVDKINGS HWY 830 721 940751 C 0.869 725 C 0.873 2019 14,900 ST LUCIE BLVD to INDRIO RDKINGS HWY 830 924 940006 F 1.050 868 D 0.986 2019 3,402 OLEANDER AVE to US 1KITTERMAN RD 750 224 124 C 0.605 203 C 0.549 2018 2,250 US 1 to LENNARD EXTKITTERMAN RD 750 128 678 C 0.346 130 C 0.351 2017 4,479 EDWARDS RD to 35TH STKIRBY LOOP RD 630 296 677 C 0.493 362 C 0.603 2016 18,500 US 1 to MARIPOSA AVELENNARD RD 1,710 953 325 D 0.557 984 D 0.575 2019 18,500 MARIPOSA AVE to MELALEUCA BLVDLENNARD RD 1,710 953 325 D 0.557 984 D 0.575 2019 18,500 MELALEUCA BLVD to JENNINGS RDLENNARD RD 1,630 953 325 D 0.585 984 D 0.604 2019 18,500 JENNINGS RD to HILLMOOR DRLENNARD RD 1,710 953 325 D 0.557 984 D 0.575 2019 18,500 HILLMOOR DR to TIFFANY AVELENNARD RD 1,710 953 325 D 0.557 984 D 0.575 2019 5,765 TIFFANY AVE to WALTON RDLENNARD RD 1,710 301 323 C 0.391 305 C 0.396 2016 4,455 WALTON RD to S OF SAVANNA CLUB BLVDLENNARD RD 790 390 679 C 10 381 C 0.977 2016 9,400 VETERANS MEMORIAL PKWY to MORNINGSIDE BLVDLYNGATE DR 920 588 306 C 0.676 626 C 0.720 2020 9,400 MORNINGSIDE BLVD to US 1LYNGATE DR 920 588 306 C 0.676 626 C 0.720 2020 6,400 LENNARD RD to HALLAHAN STMARIPOSA AVE 880 485 166 C 0.584 686 C 0.827 2019 10 * Volumes shown were adjusted using FDOT Seasonal Factors * AADT = Annual Average Daily Traffic (volumes for both directions where applicable) * Counts with an ID format of 6 digits have data extracted from FDOT count stations. * Note: A six digit number in the "STATION ID" column identifies segment counted by FDOT Page 363 of 428 Roadway Name Location AADT Volume LOS V/C PM Pk Hr Pk Dir Pk Hr Service Capacity AM Pk Hr Pk Dir V/C LOS Volume STATION ID Last Count Year Traffic Counts and Level of Service Report Fall/Winter 2019/2020 46,000 CASHMERE BLVD to BAYSHORE BLVDST LUCIE WEST BLVD 3,170 2,446 316 C 0.792 2,308 C 0.747 2019 3,590 MIDWAY RD to BELL AVESUNRISE BLVD 540 249 155 C 0.922 233 C 0.863 2016 3,814 BELL AVE to EDWARDS RDSUNRISE BLVD 750 253 153 C 0.684 286 C 0.773 2016 7,300 EDWARDS RD to CORTEZ BLVDSUNRISE BLVD 600 647 511 F 1.011 515 D 0.858 2020 7,300 CORTEZ BLVD to VIRGINIA AVESUNRISE BLVD 750 647 511 D 0.863 515 D 0.687 2020 5,300 VIRGINIA AVE to OLEANDER AVESUNRISE BLVD 750 417 509 D 0.556 411 D 0.548 2020 3,900 OLEANDER AVE to 7TH STSUNRISE BLVD 1,540 243 708 C 0.352 282 C 0.409 2017 3,900 7TH ST to US 1SUNRISE BLVD 1,710 243 708 C 0.316 282 C 0.366 2017 15,000 US 1 to HILLMOOR DRTIFFANY AVE 2,100 855 322 C 0.425 862 C 0.429 2019 15,000 HILLMOOR DR to VILLAGE GREEN DRTIFFANY AVE 2,100 855 322 C 0.425 862 C 0.429 2019 4,666 VILLAGE GREEN DR to LENNARD RDTIFFANY AVE 2,100 242 320 C 0.120 261 C 0.130 2017 7,800 CASHMERE BLVD to CALIFORNIA BLVDTORINO PKWY 630 404 709 C 0.673 443 C 0.738 2018 4,314 CALIFORNIA BLVD to EAST TORINO PKWYTORINO PKWY 630 255 238 C 0.425 223 C 0.372 2018 8,367 COMMUNITY BLVD to VILLAGE PKWYTRADITION PKWY 1,710 996 711 D 0.582 1,144 D 0.669 2018 36,500 VILLAGE PKWY to W OF I-95TRADITION PKWY 3,170 2,021 712 C 0.654 1,924 C 0.623 2019 8,200 DARWIN BLVD to PORT ST LUCIE BLVDTULIP BLVD 790 524 713 D 0.663 456 D 0.577 2019 9,133 PORT ST LUCIE BLVD to PAAR DRTULIP BLVD 790 639 714 D 0.809 493 D 0.624 2018 9,133 PAAR DR to DARWIN BLVDTULIP BLVD 790 639 714 D 0.809 493 D 0.624 2018 4,989 TURNPIKE FEEDER RD SB RAMP to US 1TURNPIKE FEEDER RD 660 653 940078 C 0.989 653 C 0.989 2015 11,200 INDIAN PINES BLVD to TURNPIKE FEEDER RD SB R...TURNPIKE FEEDER RD 870 739 940269 C 0.849 677 C 0.778 2019 13,200 INDRIO RD to INDIAN PINES BLVDTURNPIKE FEEDER RD 870 714 940745 C 0.821 751 C 0.863 2019 59,500 MARTIN C.L. to LENNARD RDUS 1 4,240 2,709 945071 C 0.650 3,186 C 0.764 2019 59,500 LENNARD RD to PORT ST LUCIE BLVDUS 1 4,040 2,709 945071 C 0.682 3,186 C 0.803 2019 31,000 PORT ST LUCIE BLVD to JENNINGS RDUS 1 3,020 1,488 945070 C 0.506 1,580 C 0.537 2019 31,000 JENNINGS RD to TIFFANY AVEUS 1 3,020 1,488 945070 C 0.506 1,580 C 0.537 2019 17 * Volumes shown were adjusted using FDOT Seasonal Factors * AADT = Annual Average Daily Traffic (volumes for both directions where applicable) * Counts with an ID format of 6 digits have data extracted from FDOT count stations. * Note: A six digit number in the "STATION ID" column identifies segment counted by FDOT Page 364 of 428 Roadway Name Location AADT Volume LOS V/C PM Pk Hr Pk Dir Pk Hr Service Capacity AM Pk Hr Pk Dir V/C LOS Volume STATION ID Last Count Year Traffic Counts and Level of Service Report Fall/Winter 2019/2020 33,500 AVENUE H to OLD DIXIE HWYUS 1 2,000 1,766 715 C 0.925 1,742 C 0.912 2020 30,000 OLD DIXIE HWY to AVENUE OUS 1 2,000 2,082 940123 F 1.041 1,628 C 0.852 2019 30,000 AVENUE O to SR A1A NORTHUS 1 2,100 2,082 940123 D 0.991 1,628 C 0.810 2019 20,500 SR A1A NORTH to JUANITA AVEUS 1 2,100 1,230 940010 C 0.612 985 C 0.490 2019 20,500 JUANITA AVE to ST LUCIE BLVDUS 1 2,100 1,230 940010 C 0.612 985 C 0.490 2019 24,500 ST LUCIE BLVD to 25TH STUS 1 2,100 1,459 940009 C 0.726 1,399 C 0.696 2019 24,500 25TH ST to INDRIO RDUS 1 2,100 1,459 940009 C 0.726 1,399 C 0.696 2019 24,500 INDRIO RD to TURNPIKE FEEDER RDUS 1 2,100 1,333 940107 C 0.663 1,326 C 0.660 2019 24,500 TURNPIKE FEEDER RD to INDIAN RIVER C.L.US 1 2,100 1,333 940107 C 0.663 1,326 C 0.660 2019 14,500 PORT ST LUCIE BLVD to LYNGATE DRVETERANS MEMORIAL PKWY 2,100 779 329 C 0.388 817 C 0.406 2019 14,911 LYNGATE DR to US 1VETERANS MEMORIAL PKWY 2,100 756 327 C 0.376 804 C 0.400 2017 9,600 US 1 to WALTON RDVILLAGE GREEN DR 2,100 619 716 C 0.308 575 C 0.286 2017 4,633 WALTON RD to TIFFANY AVEVILLAGE GREEN DR 920 249 717 C 0.286 235 C 0.270 2017 23,000 35TH ST to 25TH STVIRGINIA AVE 3,020 1,186 940032 C 0.403 1,155 C 0.393 2019 21,000 OKEECHOBEE RD to HARTMAN RDVIRGINIA AVE 3,020 1,115 940030 C 0.379 1,074 C 0.365 2019 21,000 HARTMAN RD to 35TH STVIRGINIA AVE 3,020 1,115 940030 C 0.379 1,074 C 0.365 2019 23,500 25TH ST to 13TH STVIRGINIA AVE 3,020 1,229 940033 C 0.418 1,308 C 0.445 2019 25,500 13TH ST to 11TH STVIRGINIA AVE 3,020 1,228 940794 C 0.418 1,228 C 0.418 2019 25,500 11TH ST to SUNRISE BLVDVIRGINIA AVE 3,170 1,228 940794 C 0.397 1,228 C 0.397 2019 22,000 SUNRISE BLVD to OLEANDER AVEVIRGINIA AVE 3,020 1,198 940792 C 0.407 1,118 C 0.380 2019 19,200 OLEANDER AVE to COLONIAL RDVIRGINIA AVE 3,170 1,083 940034 C 0.350 1,059 C 0.343 2019 19,200 COLONIAL RD to US 1VIRGINIA AVE 3,020 1,083 940034 C 0.368 1,059 C 0.360 2019 14,000 DISCOVERY WAY to TRADITION PKWYVILLAGE PKWY 2,650 732 718 C 0.595 797 C 0.648 2019 14,000 BECKER RD to DISCOVERY WAYVILLAGE PKWY 1,710 732 718 C 0.951 797 D 0.466 2019 23,000 TRADITION PKWY to WESTCLIFFE LNVILLAGE PKWY 1,710 1,208 719 D 0.706 1,265 D 0.740 2019 19 * Volumes shown were adjusted using FDOT Seasonal Factors * AADT = Annual Average Daily Traffic (volumes for both directions where applicable) * Counts with an ID format of 6 digits have data extracted from FDOT count stations. * Note: A six digit number in the "STATION ID" column identifies segment counted by FDOT Page 365 of 428 Roadway Name Location AADT Volume Traffic Counts and Level of Service Report 2023 LOS V/C PM Pk Hr Pk Dir Pk Hr Service Capacity AM Pk Hr Pk Dir V/C LOS Volume 69,903 3,439 3,439 OKEECHOBEE RD to ORANGE AVEI-95 0.47B 0.47B 7,320 52,086 3,018 3,018 ORANGE AVE to INDRIO RDI-95 0.41B 0.41B 7,320 5,559 276 276 CITRUS AVE to ORANGE AVEINDIAN RIVER DR 0.37C 0.37C 750 6,098 302 302 ORANGE AVE to AVENUE AINDIAN RIVER DR 0.40C 0.40C 750 6,293 312 312 AVENUE D to SEAWAY DRINDIAN RIVER DR 0.40C 0.40C 790 6,293 312 312 AVENUE A to AVENUE DINDIAN RIVER DR 0.58D 0.58D 540 1,130 56 56 PRIVATE RD to I-95 W RAMPINDRIO RD 0.05B 0.05B 1,080 1,130 56 56 I-95 W RAMP to I-95 E RAMPINDRIO RD 0.02B 0.02B 3,240 11,474 560 560 I-95 E RAMP to KOBLEGARD RDINDRIO RD 0.17B 0.17B 3,240 11,474 560 560 KOBLEGARD RD to JOHNSTON RDINDRIO RD 0.80C 0.80C 700 11,474 560 560 JOHNSTON RD to EMERSON AVEINDRIO RD 0.64C 0.64C 880 10,743 524 524 EMERSON RD to SEMINOLE RDINDRIO RD 0.57C 0.57C 920 10,743 524 524 SEMINOLE RD to KINGS HWYINDRIO RD 0.66D 0.66D 790 6,500 411 404 KINGS HWY to SLASH PINE TRLINDRIO RD 0.51D 0.52D 790 6,500 411 404 SLASH PINE TRL to US 1INDRIO RD 0.44C 0.45C 920 1,246 108 114 US 1 to OLD DIXIE HWYINDRIO RD 0.15C 0.14C 750 10,375 488 535 EDWARDS RD to OKEECHOBEE RDJENKINS RD 0.61C 0.56C 880 10,849 567 574 OKEECHOBEE RD to GRAHAM RDJENKINS RD 0.62C 0.62C 920 10,849 567 574 GRAHAM RD to PETERSON RDJENKINS RD 0.91C 0.90C 630 10,849 567 574 PETERSON RD to ORANGE AVEJENKINS RD 0.62C 0.62C 920 5,465 286 273 US 1 to LENNARD RDJENNINGS RD 0.13C 0.14C 2,100 2,909 228 200 ANGLE RD to L20JOHNSTON RD 0.19B 0.21B 1,070 2,604 172 163 L20 to MEADOWOOD DRJOHNSTON RD 0.15B 0.16B 1,070 2,604 172 163 MEADOWOOD DR to OLD JOHNSTON RDJOHNSTON RD 0.15B 0.16B 1,070 2,604 172 163 OLD JOHNSTON RD to INDRIO RDJOHNSTON RD 0.15B 0.16B 1,070 10,000 580 547 INDRIO RD to RUSSOS RDJOHNSTON RD 0.51C 0.54C 1,070 10,000 580 547 RUSSOS RD to INDIAN RIVER C.L.JOHNSTON RD 0.51C 0.54C 1,070 1,972 126 103 53RD ST to 25TH STJUANITA AVE 0.14C 0.17C 750 3,749 191 209 25TH ST to US 1JUANITA AVE 0.28C 0.26C 750 8 * Volumes shown were adjusted using FDOT Seasonal Factors * AADT = Annual Average Daily Traffic Page 366 of 428 Roadway Name Location AADT Volume Traffic Counts and Level of Service Report 2023 LOS V/C PM Pk Hr Pk Dir Pk Hr Service Capacity AM Pk Hr Pk Dir V/C LOS Volume 3,200 234 253 ANGLE RD to JUANITA AVEKEEN RD 0.40C 0.37C 630 3,200 234 253 JUANITA AVE to ST LUCIE BLVDKEEN RD 0.40C 0.37C 630 9,383 472 472 OKEECHOBEE RD to CROSSROADS PKWYKINGS HWY 0.54C 0.54C 880 9,383 472 472 CROSSROADS PKWY to GRAHAM RDKINGS HWY 0.67C 0.67C 700 7,181 361 361 GRAHAM RD to PICOS RDKINGS HWY 0.52C 0.52C 700 7,181 361 361 PICOS RD to ORANGE AVEKINGS HWY 0.41C 0.41C 880 15,247 767 767 ORANGE AVE to ANGLE RDKINGS HWY 0.83C 0.83C 920 11,202 547 547 ANGLE RD to ST LUCIE BLVDKINGS HWY 0.62C 0.62C 880 13,787 673 673 ST LUCIE BLVD to INDRIO RDKINGS HWY 0.77C 0.77C 880 2,581 150 139 EDWARDS RD to 35TH STKIRBY LOOP RD 0.22C 0.24C 630 2,600 167 136 OLEANDER AVE to US 1KITTERMAN RD 0.18C 0.22C 750 2,095 123 128 US 1 to LENNARD EXTKITTERMAN RD 0.17C 0.16C 750 20,570 1,234 1,170 US 1 to MARIPOSA AVELENNARD RD 0.68D 0.72D 1,710 20,570 1,234 1,170 MARIPOSA AVE to MELALEUCA BLVDLENNARD RD 0.68D 0.72D 1,710 20,570 1,234 1,170 MELALEUCA BLVD to JENNINGS RDLENNARD RD 0.72D 0.76D 1,630 20,570 1,234 1,170 JENNINGS RD to HILLMOOR DRLENNARD RD 0.68D 0.72D 1,710 20,570 1,234 1,170 HILLMOOR DR to TIFFANY AVELENNARD RD 0.68D 0.72D 1,710 7,365 403 389 TIFFANY AVE to WALTON RDLENNARD RD 0.23C 0.24C 1,710 3,748 259 246 WALTON RD to S OF SAVANNA CLUB BLVDLENNARD RD 0.31C 0.33C 790 9,700 612 553 VETERANS MEMORIAL PKWY to MORNINGSIDE BLVDLYNGATE DR 0.60C 0.67C 920 9,700 612 553 MORNINGSIDE BLVD to US 1LYNGATE DR 0.60C 0.67C 920 7,300 568 541 LENNARD RD to HALLAHAN STMARIPOSA AVE 0.62C 0.65C 880 364 27 25 WILLIAMS RD to MIDWAY RDMCCARTY RD 0.05C 0.05C 540 431 37 37 MIDWAY RD to OKEECHOBEE RDMCCARTY RD 0.07C 0.07C 540 4,900 307 298 OKEECHOBEE RD to KIRBY LOOP RDMCNEIL RD 0.38C 0.39C 790 4,900 307 298 KIRBY LOOP RD to EDWARDS RDMCNEIL RD 0.55D 0.57D 540 10,710 630 601 LENNARD RD to GREEN RIVER PKWYMELALEUCA BLVD 0.65C 0.69C 920 25,000 1,245 1,298 EAST TORINO PKWY to MILNER DRMIDWAY RD 1.48F 1.42F 880 25,000 1,245 1,298 MILNER DR to W OF SELVITZ RDMIDWAY RD 1.64F 1.58F 790 9 * Volumes shown were adjusted using FDOT Seasonal Factors * AADT = Annual Average Daily Traffic Page 367 of 428 Roadway Name Location AADT Volume Traffic Counts and Level of Service Report 2023 LOS V/C PM Pk Hr Pk Dir Pk Hr Service Capacity AM Pk Hr Pk Dir V/C LOS Volume 3,611 218 230 MIDWAY RD to BELL AVESUNRISE BLVD 0.43C 0.40C 540 4,050 267 270 BELL AVE to EDWARDS RDSUNRISE BLVD 0.36C 0.36C 750 7,600 586 511 EDWARDS RD to CORTEZ BLVDSUNRISE BLVD 0.85D 0.98D 600 7,600 586 511 CORTEZ BLVD to VIRGINIA AVESUNRISE BLVD 0.68D 0.78D 750 6,700 419 416 VIRGINIA AVE to OLEANDER AVESUNRISE BLVD 0.56D 0.56D 750 5,053 291 357 OLEANDER AVE to 7TH STSUNRISE BLVD 0.23C 0.19C 1,540 5,053 291 357 7TH ST to US 1SUNRISE BLVD 0.21C 0.17C 1,710 17,532 992 904 US 1 to HILLMOOR DRTIFFANY AVE 0.43C 0.47C 2,100 17,532 992 904 HILLMOOR DR to VILLAGE GREEN DRTIFFANY AVE 0.43C 0.47C 2,100 4,227 205 199 VILLAGE GREEN DR to LENNARD RDTIFFANY AVE 0.10C 0.10C 2,100 7,020 449 410 CASHMERE BLVD to CALIFORNIA BLVDTORINO PKWY 0.65C 0.71C 630 4,984 329 269 CALIFORNIA BLVD to EAST TORINO PKWYTORINO PKWY 0.43C 0.52C 630 7,590 794 770 COMMUNITY BLVD to VILLAGE PKWYTRADITION PKWY 0.45C 0.46D 1,710 46,500 2,338 2,116 VILLAGE PKWY to W OF I-95TRADITION PKWY 0.67C 0.74C 3,170 9,314 610 551 DARWIN BLVD to PORT ST LUCIE BLVDTULIP BLVD 0.70D 0.77D 790 10,813 605 647 PORT ST LUCIE BLVD to PAAR DRTULIP BLVD 0.82D 0.77D 790 10,813 605 647 PAAR DR to DARWIN BLVDTULIP BLVD 0.82D 0.77D 790 4,920 TURNPIKE FEEDER RD SB RAMP to US 1TURNPIKE FEEDER RD BB 660 11,335 553 553 INDIAN PINES BLVD to TURNPIKE FEEDER RD SB R...TURNPIKE FEEDER RD 0.64C 0.64C 870 13,204 644 644 INDRIO RD to INDIAN PINES BLVDTURNPIKE FEEDER RD 0.74C 0.74C 870 47,386 2,354 2,354 MARTIN C.L. to LENNARD RDUS 1 0.56C 0.56C 4,240 47,386 2,354 2,354 LENNARD RD to PORT ST LUCIE BLVDUS 1 0.58C 0.58C 4,040 32,450 1,612 1,612 PORT ST LUCIE BLVD to JENNINGS RDUS 1 0.53C 0.53C 3,020 32,450 1,612 1,612 JENNINGS RD to TIFFANY AVEUS 1 0.53C 0.53C 3,020 32,450 1,612 1,612 TIFFANY AVE to WALTON RDUS 1 0.53C 0.53C 3,020 44,760 2,223 2,223 WALTON RD to VILLAGE GREEN DRUS 1 0.74C 0.74C 3,020 46,801 2,325 2,325 VILLAGE GREEN DR to SPANISH LAKES BLVDUS 1 0.73C 0.73C 3,170 46,801 2,325 2,325 SPANISH LAKES BLVD to PRIMA VISTA BLVDUS 1 0.73C 0.73C 3,170 35,621 1,769 1,769 PRIMA VISTA BLVD to RIO MAR DRUS 1 0.56C 0.56C 3,170 15 * Volumes shown were adjusted using FDOT Seasonal Factors * AADT = Annual Average Daily Traffic Page 368 of 428 Roadway Name Location AADT Volume Traffic Counts and Level of Service Report 2023 LOS V/C PM Pk Hr Pk Dir Pk Hr Service Capacity AM Pk Hr Pk Dir V/C LOS Volume 31,668 1,573 1,573 RIO MAR DR to KITTERMAN RDUS 1 0.50C 0.50C 3,170 31,668 1,573 1,573 KITTERMAN RD to S OF SAEGER AVEUS 1 0.52C 0.52C 3,020 31,668 1,573 1,573 S OF SAEGER AVE to EASY STUS 1 0.50C 0.50C 3,170 29,229 1,452 1,452 EASY ST to MIDWAY RDUS 1 0.46C 0.46C 3,170 30,634 1,522 1,522 MIDWAY RD to WEATHERBEE RDUS 1 0.73C 0.73C 2,100 30,634 1,522 1,522 WEATHERBEE RD to FARMER'S MARKET RDUS 1 0.76C 0.76C 2,000 30,634 1,522 1,522 FARMER'S MARKET RD to EDWARDS RDUS 1 0.76C 0.76C 2,000 27,434 1,363 1,363 EDWARDS RD to SAVANNAH RDUS 1 0.68C 0.68C 2,000 27,434 1,363 1,363 GARDENIA AVE to VIRGINIA AVEUS 1 0.68C 0.68C 2,000 27,434 1,363 1,363 SAVANNAH RD to GARDENIA AVEUS 1 0.68C 0.68C 2,000 24,778 1,231 1,231 VIRGINIA AVE to OHIO AVEUS 1 0.62C 0.62C 2,000 24,778 1,231 1,231 OHIO AVE to GEORGIA AVEUS 1 0.76D 0.76D 1,630 27,037 1,343 1,343 GEORGIA AVE to DELAWARE AVEUS 1 0.82D 0.82D 1,630 28,871 1,434 1,434 DELAWARE AVE to CITRUS AVEUS 1 0.88D 0.88D 1,630 24,609 1,222 1,222 CITRUS AVE to ORANGE AVEUS 1 0.75D 0.75D 1,630 28,871 1,434 1,434 ORANGE AVE to AVENUE AUS 1 0.88D 0.88D 1,630 28,871 1,434 1,434 AVENUE A to AE BACKUS AVEUS 1 0.88D 0.88D 1,630 28,871 1,434 1,434 AE BACKUS AVE to AVENUE DUS 1 0.88D 0.88D 1,630 28,871 1,434 1,434 AVENUE D to SR A1A SOUTHUS 1 0.88D 0.88D 1,630 29,000 1,442 1,439 SR A1A SOUTH to AVENUE HUS 1 0.69C 0.69C 2,100 29,000 1,442 1,439 AVENUE H to OLD DIXIE HWYUS 1 0.72C 0.72C 2,000 27,651 1,373 1,373 OLD DIXIE HWY to AVENUE OUS 1 0.69C 0.69C 2,000 27,651 1,373 1,373 AVENUE O to SR A1A NORTHUS 1 0.65C 0.65C 2,100 19,670 977 977 SR A1A NORTH to JUANITA AVEUS 1 0.47C 0.47C 2,100 19,670 977 977 JUANITA AVE to ST LUCIE BLVDUS 1 0.47C 0.47C 2,100 19,097 948 948 ST LUCIE BLVD to 25TH STUS 1 0.45C 0.45C 2,100 19,097 948 948 25TH ST to INDRIO RDUS 1 0.45C 0.45C 2,100 24,070 1,195 1,195 INDRIO RD to TURNPIKE FEEDER RDUS 1 0.57C 0.57C 2,100 24,070 1,195 1,195 TURNPIKE FEEDER RD to INDIAN RIVER C.L.US 1 0.57C 0.57C 2,100 16 * Volumes shown were adjusted using FDOT Seasonal Factors * AADT = Annual Average Daily Traffic Page 369 of 428 kimley-horn.com 200 South Orange Avenue, Suite 600, Orlando, Florida 32801 407 898 1511 To:Irene Szedlmayer, AICP Senior Planner St. Lucie County Planning & Development Services From: Alex Memering, P.E. Alex Campano, E.I. Kimley-Horn and Associates, Inc. Kimley-Horn and Associates, Inc. Date: April 25, 2024 Re:O’Reilly Auto Parts Traffic Impact Study Review Kimley-Horn has reviewed the Traffic Impact Study (dated October 27, 2023) prepared by Simmons & White related to the above-mentioned project. Please find our review comments below pertaining to the development’s impacts to adjacent transportation facilities. 1.Please provide a copy of the site plan. 2.Please note access to Turnpike Feeder Road will need to be coordinated with FDOT. Additionally, ingress and egress left-turn movements at the proposed driveway connection on Turnpike Feeder Road will not be permitted. 3.Please perform an intersection analysis for Palomer Parkway at Turnpike Feeder Road and the two proposed project driveways. 4.Please perform a roadway segment analysis for Palomer Parkway in addition to Turnpike Feeder Road. 5.Please utilize the 2023 FDOT Quality/Level of Service Handbook to determine the roadway segment service volumes. 6.Please utilize the intersection analysis turning movements counts or FDOT Traffic Online Synopsis Reports, whichever is more conservative, for determining the existing roadway segment volumes. 7.Please evaluate the need for exclusive left and right turn lanes using the most recent FDOT Multimodal Access Management Guidebook. Thank you for the opportunity to assist St. Lucie County in reviewing this project. Please contact us if you have any questions or need additional information. Page 370 of 428 Page 371 of 428 Page 372 of 428 Page 373 of 428 Date Mailed: July 8, 2024 Planning and Development Services Department (772) 462-2822 Public Hearing Date: Thursday July 28, 2024 Location: BOCC Chambers SLC Administration Annex, 2300 Virginia Avenue, Fort Pierce, FL. 34982 Meeting Time: 6:00 PM (or soon thereafter) Applicant O’Reilly Automotive Stores, Inc. 233 South Patterson Springfield, MO 65802 Property Owner Wrightland, Inc. 114 Queen Elizabeth Ct. Hutchinson Island, FL 34949 Project Location 5028 Turnpike Feeder Road Fort Pierce, FL 34951 Parcel IDs 1301-615-0210-000-0 1301-615-0209-000-0 Future Land Use RU (Residential Urban) Zoning CN (Commercial, Neighbor- hood) ________________________ For more information, or to submit comments, please contact St. Lucie County: Irene Szedlmayer Senior Planner Planning & Development Services Department 2300 Virginia Ave. Fort Pierce, FL 349982 Email: szedlmayeri@stlucieco.org Telephone: 772-462-1562 Notice of Public Hearing Proposed Conditional Use Permit Project Description O’Reilly Automotive Stores, Inc. proposes to construct and operate a retail auto parts store at 5028 Turnpike Feeder Road, Fort Pierce. An auto parts store requires a Conditional Use permit in the CN (Commercial, Neighborhood) Zoning District. A Conditional Use is a use that is generally compatible with the characteristics of a zoning district, but requires individual review of its location, design, potential effect on nearby properties, and configuration to determine the appro- priateness of the use at the particular site. Public Hearing The Planning and Zoning Commission has the power to review and recommend to the Board of County Commissioners approval, approval with modifications, or disapproval, applications for conditional use permits. St. Lucie County policy strongly encourages public input at the public hearing. You may also mail or email written comments in advance of the public hearing for inclusion in the official record. Written comments should be received by the Planning and Develop- ment Services Department Planning Division by noon prior to the scheduled public hearing. Anyone with a disability requiring accommodations to attend this meet- ing may contact the SLC Community Risk Manager at least 48 hours in advance at (772) 462-1546 or TDD (772) 462-1428. Planning and Zoning Commission You are receiving this notice because you own property within 500 feet of the proposed petition. Miramar Ave. Palomar Pkwy. Subject Site Page 374 of 428 Turn p i k e F e e d e r R o a d Location Map Indrio Road Ki n g s H i g h w a y Page 375 of 428 CU-2402-000069 Page 376 of 428 ITEM NO. (ID # 2024-34394) DATE: 7/18/2024 AGENDA REQUEST TO: Planning and Zoning Commission PRESENTED BY: Thomas Reetz, Planner II SUBMITTED BY: Planning & Development Services SUBJECT: TDC Holdings, LLC (Guettler Brothers Construction) Petition to Rezone a +/- 36 Acre Parcel on the west side of Sapp Road from the IX, Industrial Extraction Zoning District to the IL, Industrial Light (28.5 acres) and IH, Industrial Heavy (7.5 acres) zoning districts. BACKGROUND: The petitioner, TDC Holdings LLC, is requesting an Amendment to the Official Zoning Atlas to rezone +/- 36 acres from the IX, Industrial Extraction Zoning District to IL, Industrial Light (28.5 acres) and IH, Industrial Heavy (7.5 acres) zoning districts. The property is located on the west side of Sapp Road, approximately 1/4 mile south of St. Lucie Boulevard. The Future Land Use designation for the parcel is Ind, Industrial. The property is situated inside the Urban Service Boundary (USB) and Airport Overlay zone. PREVIOUS ACTION: Previous Action: The 1990 Comprehensive Plan classified the subject property within the IND, Industrial Future Land Use Category. FINANCIAL IMPACT: Potential Increase in Ad-Valorem Tax Revenue RECOMMENDATION: Staff recommends the Planning and Zoning Commission forward a recommendation of approval to the Board of County Commissioners, for amendment of the Official Zoning Atlas to designate the subject parcel +/- 28.5 acres as IL, Industrial Light and +- 7.5 acres as IH, Industrial Heavy totaling +-36 acres. COMMISSION ACTION: RESULT: MOVER: None SECONDER: None AYES: None Page 377 of 428 NAYS: None EXCUSED: None Coordination/Signatures Date: July 12, 2024 Benjamin Balcer, Planning & Development Services Director Date: July 12, 2024 Katherine Barbieri, Assistant County Attorney III Date: July 12, 2024 Mayte Santamaria, Deputy County Administrator Page 378 of 428 Planning and Development Services Department Planning Division M E M O R A N D U M TO:Planning and Zoning Commission THROUGH:Benjamin Balcer, AICP, Planning and Development Services Director Kori Benton, AICP, Planning Manager FROM:Thomas Reetz, Planner II DATE:July 5, 2024 SUBJECT:Guettler Brothers Construction - RZ-2305-000023- Amendment to the Official Zoning Atlas (Rezoning) from IX, Industrial Extraction to the IL, Industrial Light (approximately 28.5 acres of the site) and IH, Industrial Heavy (approximately 7.5 acres at the NW corner of the site) zoning districts. GENERAL INFORMATION Property Owner/Applicant:TDC Holdings, LLC PO Box 15280 Fort Pierce, FL 34979 Agent:Darren Guettler, P.E. Velcon Engineering & Surveying, LLC 1449 Commerce Centre Drive Port Saint Lucie, FL 34986 Location:West side of Sapp Road, approximately 1/4 mile south of St. Lucie Boulevard, in the Airport Overlay district, St. Lucie County, Florida Parcel ID Number:1431-140-0000-000-8 Parcel Size:+/- 36 acres Future Land Use:IND, Industrial Existing Zoning:IX, Industrial Extraction Proposed Zoning:IL, Industrial Light (28.5 Acres); IH, Industrial Heavy (7.5 Acres) Existing Use(s): Location for temporary stockpiles of soil and debris including concrete and asphalt millings. The property is also used as pasture for livestock grazing. Fire/EMS:Station #4 (Airport) is located at 3601 Industrial 33rd St, Fort Pierce, FL 34946 approximately 1.5 miles northeast of the subject property. Right-of-Way:Access from Sapp Rd via St. Lucie Blvd.; County ROW Page 379 of 428 Project Name: Guettler Brothers Construction Rezoning File No.: RZ-2305-000023 Utilities:FPUA service area, a water line is available on the north side of St. Lucie Blvd., however sewer is not immediately available (+/-1,250 to the north). FP&L electric service is available. Type of Concurrency Document Required:Concurrency Deferral Affidavit BACKGROUND ANALYSIS The petitioner, TDC Holdings LLC, is requesting an Amendment to the Official Zoning Atlas to rezone +/- 36 acres from the IX, Industrial Extraction Zoning District to the IL, Industrial Light and IH, Industrial Heavy zoning districts. The property is located on the west side of Sapp Road, approximately 1/4 mile south of St. Lucie Boulevard. The Future Land Use designation for the parcel is IND, Industrial. The property is located within the Urban Service Boundary (USB) and Airport Overlay Zone. Figure 1: Aerial Future Land Use: The Future Land Use designation of the subject property is IND, Industrial. Comprehensive Plan Policy 1.1.1.2.K. describes the IND future land use category as follows: This land use designation is applied to specific areas of the County identified as suitable for industrial use. This land use designation is intended to be implemented through both the heavy and light industrial zoning districts, with the specific criteria for zoning application as provided for under the policies of the Future Land Use Element. Page 380 of 428 Project Name: Guettler Brothers Construction Rezoning File No.: RZ-2305-000023 Areas designated for Industrial activities must have available all necessary services and facilities prior to development, supplied by either public or private sources as permitted. In addition, developments proposing to incorporate heavy industrial uses will be required to be adequately buffered from any adjacent use that would be incompatible. Limited nonresidential uses may be appropriate, in accordance with applicable standards and restrictions as set forth in the Land Development Code Current Zoning: The current zoning of the subject property is IX, Industrial Extraction. The St. Lucie County Land Development Code (LDC), Section 3.01.03.V. provides as follows: Purpose. The purpose of this district is to provide and protect an environment suitable for the extraction of natural resources from the ground, together with such other uses as may be necessary to and compatible with industrial extraction surroundings. The number 999 applies to a use not defined under the SIC Code but may be further defined in Section 2.00.00 of this Code. Proposed Zoning: The proposed zoning for approximately 28.5 acres of the subject property is IL, Industrial Light. LDC Section 3.01.03.T. provides as follows: Purpose. The purpose of this district is to provide and protect an environment suitable for light manufacturing, wholesale, and warehousing activities that do not impose undesirable noise, vibration, odor, dust, or other offensive effects on the surrounding are, together with such other uses as may be necessary to and compatible with light industrial surroundings. Figure 2: Future Land Use Map Page 381 of 428 Project Name: Guettler Brothers Construction Rezoning File No.: RZ-2305-000023 IL permitted uses include a wide variety of office, manufacturing, motor freight transportation & warehousing, repair services, retail trade, vocational schools, and wholesale trade. Mobile vendors, landscape services, and personal services are also permitted uses. Single-family detached dwelling units provided that the single-family dwelling unit is located on an existing lot or parcel or record, as further defined in this Code, that existed on or before August 1, 1990. (999) Conditional uses include, manufacturing, boat building and repair, wholesale: petroleum bulk station and terminals, scrap and waste materials and kennels. Accessory uses include one (1) detached single-family dwelling or mobile home, for on-site security purposes per property. The proposed zoning for approximately 7.5 acres of the subject property is IH, Industrial Heavy. LDC Section 3.01.03.U. provides as follows: Purpose. The purpose of this district is to provide an environment suitable for heavy manufacturing and other activities that may impose undesirable noise, vibration, odor, dust, or other offensive effects on the surrounding area together with such other non-residential uses as may be necessary to and compatible with heavy industrial surroundings. The number 999 applies to a use not defined under the SIC Code but may be further defined in Section 2.00.00 of this Code. IH permitted uses include agricultural services, construction services, engineering services, a wide range of manufacturing, wholesale and retail trade. Conditional uses include a range of manufacturing, warehousing and storage services, scrap waste and recycling, wholesale trade of non-durable goods including petroleum and petroleum products. Accessory uses include one (1) detached single-family dwelling or mobile home, for on-site security purposes per property. [Remaining Page Intentionally Let Blank] Figure 3: Current Zoning Page 382 of 428 Project Name: Guettler Brothers Construction Rezoning File No.: RZ-2305-000023 Figure 4B: Proposed Zoning - Zoomed Figure 4: Proposed Zoning Page 383 of 428 Project Name: Guettler Brothers Construction Rezoning File No.: RZ-2305-000023 ********************************************** In reviewing this application for an amendment to the Official Zoning Atlas, the Board of County Commissioners shall consider and make the following determinations: A. Whether the proposed rezoning is in conflict with any applicable portions of the St. Lucie County Land Development Code; The proposed IL & IH zoning designations are consistent with the Comprehensive Plan’s Future Land Use Map (FLUM) designation of IND. The proposed rezoning to the IL & IH Zoning Districts are consistent with the St. Lucie County Land Development Code (LDC) and meets the Standards of Review set forth in LDC Section 11.06.03, as displayed in Sections A thru J of this report. The rezoning is consistent with LDC Section 11.09.02(A), Table 11-1 - Zoning District/ Land Use Category Compatibility Chart and the site meets the dimensional requirements set forth in Section 7.04.00 and Table 7-10 – Lot Size and Dimensional Requirements for the IL & IH Zoning Districts. The proposed IL and IH Zoning Districts are consistent with surrounding parcels, providing the use scope in LDC Sections 3.01.03(T)(U) and District purposes. Certain Conditional Uses outlined under the Heavy Industrial Zoning District may not be appropriate for this particular property, due to its proximity to the single- family dwellings, +/- 1000 feet to the south. All future uses will be required to be reviewed by the St. Lucie County Development Review Committee for compliance with design standards, and Conditional Uses evaluated with greater examination for compatibility with the subject site and surrounding uses. B. Whether the proposed amendment is consistent with all elements of the St. Lucie County Comprehensive Plan; The IL & IH Zoning Districts are consistent with the IND Future Land Use designation as provided within Comprehensive Plan Policy 1.1.1.3 - Land Use Designation / Zoning Compatibility Chart. FUTURE LAND USE CATEGORIESZONING DISTRICT AG-5 AG-2.5 RE RS RU RM RH R/C Cpub COM IND P/F MXD SD H T/U TVC IL, Industrial Light X X IH, Industrial Heavy X X The proposed amendment is consistent with the following Comprehensive Plan Future Land Use Element’s (FLUE) Goals, Objectives, and Policies: The proposed rezoning conforms to the IND FLUM, and is consistent with most Urban Sprawl policies associated with FLUE Objective 1.1.5; is within the Urban Service Boundary as set forth in FLUE Objective 1.1.10.6 and its policies. Future Land Use Element Policy 1.1.13.2 sets forth the following specific criteria to be utilized for determining the suitability of new property for IH zoning, applicable to the +/- 7.5-acre portion proposed at the NW corner of the property: and strengthens the industrial base, tax base, and job market as called for in Economic Development Element Policy 10.1.1.1. 1. Heavy Industrial property should have available to it central water services necessary for both domestic and fire protection purposes. STANDARDS OF REVIEW AS SET FORTH IN THE LAND DEVELOPMENT CODE SECTION 11.06.03 Page 384 of 428 Project Name: Guettler Brothers Construction Rezoning File No.: RZ-2305-000023 A water line runs along St. Lucie Blvd approximately ¼ mile north of the property. 2. New Heavy Industrial property should not be located within 1000 feet of any Aquatic Preserve or other specially designated aquatic habitat, or a Category I Wetlands as described in the Conservation Element of this Plan. The subject property is not within 1000 feet of such areas (known). 3. New Heavy Industrial property should not be located within the 100-year flood Plain. The property is located outside of the Special Flood Hazard Area and in Zone X. 4. Heavy Industrial property should have immediate access to the regional transportation network without the need to travel through residential areas. The property has immediate access to the regional transportation network, with direct access to St. Lucie Boulevard is a State Road without having to go through residential areas. I-95 is approximately four miles away via N. Kings Highway and then east on Orange Avenue. Future Site Plan development will warrant extension and improvement to Sapp Road, and further transportation impact evaluation. 5. New Heavy Industrial property should not be located within any cone of influence, as identified under the County's wellfield protection program. The property is located outside any Wellfield Protection zone. Future Land Use Element Policy 1.1.13.3 sets forth the following specific criteria to be utilized for determining the suitability of new property for IL zoning: and strengthens the industrial base, tax base, and job market as called for in Economic Development Element Policy 10.1.1.1. 1. Light Industrial property should have available to it central water services necessary for both domestic and fire protection purposes. A water line runs along St. Lucie Blvd approximately ¼ mile north of the property. 2. New Light Industrial property should not be located within 500 feet of any Aquatic Preserve or other specially designated aquatic habitat, or Category I Wetlands as described in the Conservation Element of this Plan. The subject property is not within 500 feet of such areas. 3. New Light Industrial areas should have immediate access to the regional transportation network. The property has immediate access to the regional transportation network – St. Lucie Boulevard is a State Road. I-95 is approximately four miles away via N. Kings Highway and then east on Orange Avenue, and roughly 8 miles, navigating Kings Highway north to Indrio Road, and west to I-95. 4. Light Industrial development shall not contribute to the degradation of surficial water quality. Development on the site will be subject to LDC natural resource protection standards, agency stormwater standards, and other standards that protect surface water quality. Page 385 of 428 Project Name: Guettler Brothers Construction Rezoning File No.: RZ-2305-000023 Also, FLUE Objective 1.1.5 policies discourage urban sprawl. The property is an infill project and not in a sprawl location, just south of the Treasure Coast Airport and Northwest of the Fort Pierce city limits. A water main line and sewer force main runs along St. Lucie Blvd less than a 1/4 mile away from the site; Additionally, the property is not far from employment centers and emerging commercial areas. C. Whether and the extent to which the proposed zoning is inconsistent with the existing and proposed land uses; The subject parcel is situated along Sapp Road ¼ mile south of St. Lucie Blvd., with properties in the IND, Industrial Future Land Use located the north, east, and west. St Lucie Blvd. is a county owned and maintained arterial roadway, which is suitable to serve industrial uses. The proposed industrial zoning is in keeping with similar existing industrial uses in the St. Lucie Blvd. corridor. The requested rezone is not expected to harm other properties or improvements in the area. This amendment will not create a conflict with the surrounding zoning districts. The south side of St. Lucie Boulevard is a pocket of industrial uses within a larger area with lands historically used for light industrial uses. Surrounding Land Use and Zoning Location Future Land Use Zoning Existing Land Use Subject Property IND (Industrial)IX, Industrial Ext.Fill storage, cattle grazing North T/U (Transportation Utilities) IL, Industrial, Light Truss manufacturing South SLC ROW Canal No. 1 & RU, (Residential Urban) U (Utilities)Canal No.1 abutting to the south and Single-Family Res., further south East IND IL Undeveloped Adjacent Parcels West IND IL Undeveloped/Storage yard D. Whether there have been changed conditions that require an amendment. Changed conditions include ongoing improvements to Interstate 95, Florida’s Turnpike, Kings Highway and Orange Avenue which have improved the accessibility of properties in this area for trucking/freight distribution, warehouses, and manufacturers, and have increased demand for properties with industrial zoning. Additionally, investment in and expansion of the Treasure Coast International Airport remains underway. The site has historically been used for mining fill dirt with a barrow pit that hasn’t been used in decades and has become partially filled with water. The owner is said to be in the process of stabilizing its shoreline with littoral plantings. E. Whether and the extent to which the proposed amendment would result in demands on public facilities, and whether or to the extent to which the proposed amendment would exceed the capacity of such public facilities, including but not limited to transportation facilities, sewage facilities, water supply, parks, drainage, schools, solid waste, mass transit, and emergency medical facilities. The property is located within the Urban Service Boundary and is within ¼ miles of a water line and sewer line. The proposed change in zoning should not adversely affect the acceptable level of service capacity of transportation facilities, sewage facilities, water supply, parks, drainage, schools, solid waste, mass transit, or emergency medical facilities. Prior to the issuance of any Final Development Order, the developer must demonstrate that all public facilities are available to serve the parcel and obtain a Certificate of Capacity. The applicant has signed the required Concurrency Deferral Affidavit recognizing this requirement. Page 386 of 428 Project Name: Guettler Brothers Construction Rezoning File No.: RZ-2305-000023 Transportation: The property is adjacent to the Treasure Coast International Airport, with connectivity via St. Lucie Boulevard to I-95/Turnpike via Kings Highway. The Applicant’s Transportation statement, for an associated site plan*, indicated generation per the Institute of Transportation Engineers trip generation for the (150) Warehouse category of sixty-nine (69) weekday daily trips, nine (9) AM peak hour trips and ten (10) PM peak hour trips. St. Lucie Blvd has an existing west bound turning land onto Sapp Road. Further analysis will be required with future development proposal(s). Sewer: The closest sewer main is located 1/4 miles to the north, along St Lucie Blvd. Water: A water line runs along St Lucie Blvd. ¼ miles north, along St Lucie Blvd. Parks: N/A (nonresidential). Drainage: Development of the property is subject to County, South Florida Water Management District, US Army Corps of Engineers, and Florida Department of Environmental Protection standards. Schools: N/A (nonresidential) Solid Waste: This area is served by WastePro. Mass Transit: The Area Regional Transit (ART) provides a fixed route service to the north of this property (St. Lucie Blvd.) and the vicinity via Route 2 which serves northern and downtown Fort Pierce, with links to Route 7, and others from Route 2. Emergency Medical Facilities: The nearest Fire/EMS station is Station # 4, approximately 1.7 miles to the north on the east side of the airport. Site-specific impacts will be addressed through permitting or a development application. F. Whether and the extent to which the proposed amendment would result in significant adverse impacts on the natural environment; The County’s Environmental Resources Department provided the following statement: ERD has no objection to the rezoning of the subject parcel. Further review of the development plans will be conducted as part of the site plan approval or building permit process. Their detailed findings are noted, further below. A minor Site plan application is being reviewed for the new location of Guettler Brothers Construction headquarters. ERD has reviewed the application and provided a report with a partial list of conditions of approval. ERD will conduct further review of the site plan or building permit review process, including but not limited to, tree mitigation requirements, updating listed species surveys as necessary per individual species requirements, a vegetation removal permit or exemption, issued by the department. Clearing and earthwork will be conducted outside of the Scrub-jay nesting season and prior to Certificate of occupancy invasive plant species shall be removed from the site. Page 387 of 428 Project Name: Guettler Brothers Construction Rezoning File No.: RZ-2305-000023 Findings An Environmental Impact Report (EIR), prepared by EW Consultants, Inc. and revision dated February 2024, was submitted and reviewed. The site is comprised of two land cover types including undeveloped previously cleared lands +and a man-made reservoir. The vegetation assemblage within the upland portions of the property consists predominantly of pasture grasses, ruderal weeds, and non-native invasive species. Native trees and palms including slash pine, cabbage palm, and live oak are also present to a lesser extent. The property does not contain any wetlands or native upland habitat. There is an abandoned, flooded, man-made extraction pit located within the central portion of the property. The flooded pit is the result of a past fill excavation operation that was active more than fifty years ago. The pit is characterized as having steep-sloped edges that are vegetated with occurrences of Carolina willow, nuisance cattail, and non-native, invasive Peruvian primrose willow, and napier grass. The central portions of the pit do not contain any emergent vegetation. The upland portions of the property exhibit indicators of past use of the land as a fill excavation operation. A man-made berm encompasses most of the property, extending along the north, east, south, and west property boundaries. The eastern portion of the property also contains temporary stockpiles of soil and debris including concrete and asphalt millings. The property is also used as pasture for livestock grazing. Most of the site is mapped, using the Florida Land Use, Cover and Forms Classification System (FLUCFCS), as Undeveloped Lands within Urban Areas (24.1 acres) with the remainder mapped as Reservoirs Greater than 10 Acres & less than 100 Acres (12.0 acres). A potentially occupied Gopher Tortoise burrow was identified on the subject parcel. A 100% Gopher Tortoise survey, conducted by a certified FFWCC agent will be required prior to the issuance of a Vegetation Removal Permit or Site Development Permit. The site abuts a County Preserve with a known Florida Scrub Jay population. Correspondence was received from Adam Knutson, Fish and Wildlife Biologist of the U.S. Fish and Wildlife Service, indicating that they have no objection the development of the lot with sole condition that clearing and earthwork activities be conducted outside of the Florida Scrub Jay nesting season of March 1st through June 30th. Between 2018 and 2019, most of trees located on the site were removed under an agricultural exemption. No native upland habitat remains onsite. No remaining native trees are proposed to be impacted by the rezoning or development of the parcel. G.Whether and the extent to which the proposed amendment would adversely affect the property values in the area; Given the prevalence of like uses in the vicinity, it is not likely that the proposed change in zoning will adversely affect the property values in the area. The proposed zoning is consistent with the existing Future IND Industrial Land Use designation. This is an expansion of the current concentration of industrial uses on the south side of St. Lucie Boulevard, which is in keeping with orderly and logical development that is in keeping with IND FLUM land uses. H. Whether and the extent to which the proposed amendment would result in an orderly and logical development pattern specifically identifying any negative effects of such patterns; The proposed change in zoning will result in an orderly and logical development pattern. The subject property is in the Urban Service Boundary and is served by improved roadways with central water and sewer lines along those roadways, with the developer agreeing to extend these lines to serve this industrial property. The positioning of the proposed IH designation is internal to surrounding Industrial, Light, zoning and uses to minimize impacts, and avoid Heavy Industrial activities along the frontage of Sapp Road, or within 1,000 ft. of residential property to the south. The Airport Overlay Zone will guide any height or use restrictions Page 388 of 428 Project Name: Guettler Brothers Construction Rezoning File No.: RZ-2305-000023 beyond the baseline Dimensional Criteria of Table 7-10, Land Development Code. I. Whether the proposed amendment would be in conflict with the public interest, and is in harmony with the purpose and intent of this Code; The proposed rezoning to IL and smaller portion of the property to the IH Zoning District is not in conflict with the public interest and is in harmony with the purpose and intent of the Land Development Code. J. Any other matters that may be deemed appropriate by the Planning and Zoning Commission or the Board of County Commissioners, in review and consideration of the proposed amendment. The Planning and Zoning Commission & Board of County Commissioners may raise other matters regarding the proposed amendment. CONCLUSION: Staff has reviewed this petition and determined that it conforms to the Standards of Review as set forth in Section 11.06.03 of the St. Lucie County Land Development Code and is consistent with the St. Lucie County Comprehensive Plan Goals, Objectives, and Policies. A leading justification for the rezoning is the existing Industrial (IND) Future Land Use, which allows for this zoning category, along with the presence of similar adjacent and nearby industrial uses. Also, the site has not been used for mining purposes in many decades with the borrow pit being restored to sustainable eco-friendly environment. The potentially more intense Industrial Heavy rezoning being limited to 7.5 acres located in the NW corner of the site furthest +- 1,000 feet away from neighboring the residential area to the south and +- 700 feet away from the county owned preserve property to the east. The site is not located in any designated flood plain or flood prone area as identified by the national flood insurance mapping program and is not located in an area of the County that is subject to transportation capacity concerns. PUBLIC NOTICE & NEIGHBORHOOD INPUT: The Planning and Zoning Commission Hearing was noticed by a publication in the St. Lucie News Tribune on July 5, 2024; a sign was placed on the property; and written notice was mailed on July 2, 2024, to owners of property within 500 feet of the subject property. Staff received concerns via a mailed letter from Charles Revson (a neighboring property owner) to the proposed rezoning. Mr. Revson’s letter, addressed to the St. Lucie Planning and Zoning Commission, is included in the agenda package. RECOMMENDATION: Staff has reviewed the application for amendment of the Official Zoning Atlas to designate +/- 28.5 acres as IL, Industrial Light and +- 7.5 acres as IH, Industrial Heavy, totaling +- 36 acres and recommends the Planning and Zoning Commission forward a recommendation of approval to the Board of County Commissioners, Page 389 of 428 RESOLUTION No. 2024-XXX FILE NO.: RZ-2305-000023 A RESOLUTION OF THE BOARD OF COUNTY COMMISSIONERS OF ST. LUCIE COUNTY, FLORIDA, AMENDING THE OFFICIAL ZONING ATLAS FOR A PARCEL TOTALING +/- 36 ACRES OWNED BY TDC HOLDINGS, LLC FROM IX, INDUSTRIAL EXTRACTION TO THE IL, INDUSTRIAL LIGHT (APPROXIMATELY 28.5 ACRES OF THE SITE) AND IH, INDUSTRIAL HEAVY (APPROXIMATELY 7.5 ACRES AT THE NW CORNER OF THE SITE) ZONING DISTRICTS. WHEREAS, the Board of County Commissioners of St. Lucie County, Florida, based on testimony and evidence, including, but not limited to the staff report, has made the following determinations: 1) TDC Holdings, LLC in behalf of Guettler Brothers Construction, Inc. presented a petition for an Amendment to the Official Zoning Atlas from IX, Industrial Extraction to the IL, Industrial Light (approximately 28.5 acres of the site) and IH, Industrial Heavy (approximately 7.5 acres at the NW corner of the site) zoning district designations, for a property located on the west side of Sapp Road, approximately 1/4 mile south of St. Lucie Boulevard, in the Airport Overlay district, St. Lucie County, Florida, as depicted on the attached map as Exhibit A and described in Part A. 2) On July 18, 2024, the St. Lucie County Planning and Zoning Commission held a public hearing on this petition, after advertising in the newspaper of local circulation, installing a sign on the property, and notifying by mail all owners of property within 500 feet of the subject at which all interested persons were given an opportunity to be heard and recommended that the Board of County Commissioners approve/deny the request for the property described in Part A. 3) On _____________, 2024, the Board of County Commissioners of St. Lucie County, Florida, held the first public hearing of which due notice was published in the St. Lucie News Tribune and via a sign posted on the property. 4) The St. Lucie County Development Review Committee has reviewed the Rezone Petition and found it to meet the technical requirements and to be consistent with the St. Lucie County Comprehensive Plan. 5) The proposed change in zoning has/has not satisfied the requirements of Section 11.06.03 of the St. Lucie County Land Development Code and is/is not consistent with the goals, objectives, and policies of the St. Lucie County Comprehensive Plan. NOW, THEREFORE, BE IT RESOLVED by the Board of County Commissioners of St. Lucie County, Florida: Page 390 of 428 Resolution No. 2024-XXX File No.: RZ-2305-000023 Page 2 ZONING MAP AMENDMENT A. The property on which the Zoning Map Amendment, or change in zoning, from IX, Industrial Extraction to the IL, Industrial Light (approximately 28.5 acres of the site) and IH, Industrial Heavy (approximately 7.5 acres at the NW corner of the site) zoning district designations, is being granted, is generally depicted herein by “Exhibit C”, and granted is described as follows: Legal Description: IL, Industrial Light Zoning A PARCEL OF LAND FOR REZONING, LYING IN A PORTION OF PARCEL IDENTIFICATION NUMBER 1431-140-0000-000-8, RECORDED IN OFFICIAL RECORD BOOK 3090, PAGE 547, LYING IN SECTION 31, TOWNSHIP 34 SOUTH, RANGE 40 EAST, ST. LUCIE COUNTY, FLORIDA. SAID PARCEL OF LAND FOR REZONING BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS: COMMENCING AT THE NORTHEAST CORNER OF SAID SECTION 31; THENCE ALONG THE EAST LINE OF THE NORTHEAST QUARTER OF SAID SECTION 31, SOUTH 00°11'27" WEST, A DISTANCE OF 1333.36 FEET; THENCE DEPARTING FROM SAID SECTION LINE AND ALONG THE NORTH LINE OF THE SOUTHEAST QUARTER OF THE NORTHEAST QUARTER OF SAID SECTION 31, NORTH 89°48'10" WEST, A DISTANCE OF 30.00 FEET TO THE NORTHEAST BOUNDARY CORNER OF SAID PARCEL, AS RECORDED IN OFFICIAL RECORD BOOK 3090, PAGE 547, SAID POINT ALSO BEING THE POINT OF BEGINNING; THENCE DEPARTING FROM SAID QUARTER SECTION LINE AND ALONG THE WESTERLY RIGHT OF WAY LINE OF SAPP ROAD AS RECORDED IN OFFICIA RECORD BOOK 155, PAGE 53, ST LUCIE COUNTY, FLORIDA, SOUTH 00°11'27" WEST, A DISTANCE OF 1205.32 FEET TO THE SOUTHEAST BOUNDARY CORNER OF SAID PARCEL; THENCE ALONG THE NORTH RIGHT OF WAY LINE OF CANAL NO. 1, NORTH 89°49'01" WEST, A DISTANCE OF 1303.41 FEET TO A POINT ON THE WES LINE OF THE SOUTHEAST QUARTER OF THE NORTHEAST QUARTER OF SAID SECTION 31 SAID POINT ALS BEING THE SOUTHEAST BOUNDARY CORNER OF SAID PARCEL; THENCE DEPARTING SAID NORTH RIGHT OF WAY LINE AND ALONG SAID QUARTER SECTION LINE, NORTH 00°10'14" EAST, A DISTANCE OF 710.32 FEET; THENCE DEPARTING SAID QUARTER SECTION LINE, SOUTH 89°48'10" EAST, A DISTANCE OF 663.66 FEET; THENCE NORTH 00°11'27" EAST, A DISTANCE OF 495.32 FEET TO A POINT ON SAID NORTH LINE OF THE SOUTHEAST QUARTER OF THE NORTHEAST QUARTER OF SAID SECTION 31; THENCE ALONG SAID NORTH QUARTER SECTION LINE, SOUTH 89°48'10" EAST, A DISTANCE OF 640.00 FEET TO THE POINT OF BEGINNING SAID PARCEL OF LAND FOR REZONING CONTAINING WITHIN SAID BOUNDS 1,242,725 SQUARE FEET (28.53 ACRES) MORE OR LESS. Legal Description: IH, Industrial Heavy Zoning A PARCEL OF LAND FOR REZONING, LYING IN A PORTION OF PARCEL IDENTIFICATION NUMBER 1431-140-0000-000-8, RECORDED IN OFFICIAL RECORD BOOK 3090, PAGE 547, LYING IN SECTION 31, TOWNSHIP 34 SOUTH, RANGE 40 EAST, ST. LUCIE COUNTY, FLORIDA. SAID PARCEL OF LAND FOR REZONING BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS: COMMENCING AT THE NORTHEAST CORNER OF SAID SECTION 31; THENCE ALONG THE EAST LINE OF THE NORTHEAST QUARTER OF SAID SECTION 31, SOUTH 00°11'27" WEST, A DISTANCE OF 1333.36 FEET; THENCE DEPARTING FROM SAID SECTION LINE AND ALONG THE NORTH LINE OF THE SOUTHEAST QUARTER OF THE NORTHEAST QUARTER OF SAID SECTION 31, NORTH 89°48'10" WEST, A DISTANCE OF 670.00 FEET TO THE POINT OF BEGINNING; THENCE DEPARTING FROM SAID QUARTER SECTION LINE, SOUTH 00°11'27" WEST, A DISTANCE OF 495.32 FEET; THENCE NORTH 89°48'10" WEST, A DISTANCE OF 663.66 FEET TO A POINT ON THE WEST LINE OF THE SOUTHEAST QUARTER OF THE NORTHEAST QUARTER OF SAID SECTION 31; THENCE ALONG SAID QUARTER SECTION LINE, NORTH Page 391 of 428 Resolution No. 2024-XXX File No.: RZ-2305-000023 Page 3 00°10'14" EAST, A DISTANCE OF 495.32 FEET TO THE NORTHWEST BOUNDARY CORNER OF SAID PARCEL, AS RECORDED IN OFFICIAL RECORD BOOK 3090, PAGE 547; THENCE ALONG SAID NORTH LINE OF THE SOUTHEAST QUARTER OF THE NORTHEAST QUARTER OF SAID SECTION 31, SOUTH 89°48'10" EAST, A DISTANCE OF 663.83 FEET TO THE POINT OF BEGINNING. SAID PARCEL OF LAND FOR REZONING CONTAINING WITHIN SAID BOUNDS 328,769 SQUARE FEET (7.55 ACRES) MORE OR LESS. B. The St. Lucie Planning and Development Services Director shall be authorized to amend the Official Zoning Map to change the zoning of the property herein described, from IX, Industrial Extraction to the IL, Industrial Light (approximately 28.5 acres of the site) and IH, Industrial Heavy (approximately 7.5 acres at the NW corner of the site) zoning district designations and to make a notation of the reference to the date of adoption of this Resolution. C. A Concurrency Deferral Affidavit, a copy which is attached to this Resolution as Exhibit "B" was signed by the applicant on May 26, 2023. D. A copy of this Resolution shall be mailed to the owner of record as identified on the application. E. This Resolution shall be recorded in the Public Records. F. ADOPTION, After the motion and second, the vote on this Resolution was as follows: Cathy Townsend, Chair XX Chris Dzadovsky, Vice-Chair XX Linda Bartz, Commissioner XX Larry Leet, Commissioner XX Jamie Fowler, Commissioner XX PASSED AND DULY ADOPTED this ___ day of __________, 2024. BOARD OF COUNTY COMMISSIONERS ST. LUCIE COUNTY, FLORIDA BY Chair ATTEST APPROVED AS TO FORM AND CORRECTNESS Deputy Clerk County Attorney Page 392 of 428 Resolution No. 2024-XXX File No.: RZ-2305-000023 Page 4 Exhibit A Location Map Page 393 of 428 Resolution No. 2024-XXX File No.: RZ-2305-000023 Page 5 Exhibit B Concurrency Deferral Affidavit Page 394 of 428 Exhibit C Zoning District Boundaries (IL / IH) Page 395 of 428 Page 396 of 428 Page 397 of 428 Page 398 of 428 Page 399 of 428 Page 400 of 428 Environmental resources Final report TO:Thondra Lanese, Planning & Development Services Department THROUGH:Aimee L. Cooper, Environmental Regulations Manager Amy E. Griffin, Environmental Resources Director FROM:Brian Ingram, Environmental Planner DATE:June 18, 2024 SUBJECT:Guettler Brothers Construction RZ-2305-000023 (Note: Concurrent Site Plan Project, MNSP-2305-000069) Background The Environmental Resources Department (ERD) is in receipt of the May 31, 2024, date-stamped submittal, transmitted June 3, 2024, with comments due June 18, 2024, from Planning and Development Services. The applicant is requesting approval of the rezoning, from Industrial Extraction (IE), of the northwestern corner of the parcel to Industrial Heavy (IH), with the remaining 28.52 acres to be rezoned to Industrial Light. A Minor Site Plan application (MNSP-2305- 000069) was submitted concurrently for the construction of two 100’ x 100’, two-story office and storage buildings, a 175’ x 100’ manufacturing shop, a 244’ x 440’ equipment laydown area, and associated landscaping and infrastructure. The 36.12-acre project parcel (Parcel ID: 1431-140-0000-000-8) is located about one quarter (1/4) mile south of St. Lucie Blvd. on the west side of Sapp Rd at TBD Sapp Rd., in Ft. Pierce. Findings An Environmental Impact Report (EIR), prepared by EW Consultants, Inc. and revision dated February 2024, was submitted and reviewed. The site is comprised of two land cover types including undeveloped previously cleared lands +and a man-made reservoir. The vegetation assemblage within the upland portions of the property consists predominantly of pasture grasses, ruderal weeds, and non-native invasive species. Native trees and palms including slash pine, cabbage palm, and live oak are also present to a lesser extent. The property does not contain any wetlands or native upland habitat. There is an abandoned, flooded, man-made extraction pit located within the central portion of the property. The flooded pit is the result of a past fill excavation operation that was active more than fifty years ago. The pit is characterized as having steep-sloped edges that are vegetated with occurrences of Carolina willow, nuisance cattail, and non-native, invasive Peruvian primrose willow, and napier grass. The central portions of the pit do not contain any emergent vegetation. The upland portions of the property exhibit indicators of past use of the land as a fill excavation operation. A man-made berm encompasses most of the property, extending along the north, east, south, and west property boundaries. The eastern portion of the property also contains temporary stockpiles of soil and debris including concrete and asphalt millings. The property is also used as pasture for livestock grazing. Most of the site is mapped, using the Florida Land Use, Cover and Forms Classification System (FLUCFCS), as Undeveloped Lands within Urban Areas (24.1 acres) with the remainder mapped as Reservoirs Greater than 10 Acres & less than 100 Acres (12.0 acres). A potentially occupied Gopher Tortoise burrow was identified on the subject parcel. A 100% Gopher Tortoise survey, conducted by a certified FFWCC agent will be required prior to the issuance of a Vegetation Removal Permit or Site Development Permit. The site abuts a County Preserve with a known Florida Scrub Jay population. Correspondence was received from Adam Knutson, Fish and Wildlife Biologist of the U.S. Fish and Wildlife Service, indicating that they have no objection the Page 401 of 428 development of the lot with sole condition that clearing and earthwork activities be conducted outside of the Florida Scrub Jay nesting season of March 1st through June 30th. Between 2018 and 2019, most of trees located on the site were removed under an agricultural exemption. No native upland habitat remains onsite. No remaining native trees are proposed to be impacted by the rezoning or development of the parcel. ERD has no objection to the rezoning of the subject parcel. Further review of the development plans will be conducted as part of the site plan approval or building permit process. Conditions of Approval (Site Plan) Subject to resolution of the findings listed above, the following is a partial list of conditions of approval – associated with the pending Site Plan: 1) Prior to commencement of development, including, but not limited to clearing, filling, excavation, grading, or planting of vegetation, as defined in LDC 2.00.00., listed species surveys shall be updated as necessary per individual species-specific requirements. If any listed species impacts are found to be present as a result of these surveys, appropriate mitigative measures per state and federal agency requirements shall be provided prior to initiation of any clearing activities. 2) Prior to commencement of development, including, but not limited to clearing, filling, excavation, grading, or planting of vegetation, as defined in LDC 2.00.00., a Vegetation Removal Permit or Exemption shall be issued by the Environmental Resources Department per LDC 6.00.03. 3) All clearing and earthwork activities shall be conducted outside of the Florida Scrub Jay nesting season of March 1st through June 30th, per the written correspondence provided by Adam Knutson, Fish and Wildlife Biologist with U.S. Fish and Wildlife Service 4) Prior to issuance of a Certificate of Occupancy, all Category I listed invasive plant species shall be eradicated from the site. Please contact Brian Ingram at 772-462-2393 if you have any questions or if you would like to meet regarding the details of these requirements. Page 402 of 428 Date Mailed Friday, July 5, 2024 Planning and Development Services Department 772.462. 2822 Applicant/Property Owner Guettler Brothers Construction/ TDC Holdings LLC PO Box 15280 Fort Pierce, FL 34945 Project Location Sapp Rd, 1/4 mile south of St. Lucie Blvd. Parcel ID # 1431-140-0000-000-8 Fort Pierce, FL Future Land Use I (Industrial) Existing Zoning IX (Industrial Extraction) Proposed Zoning IL (Industrial, Light) & IH (Industrial Heavy) Staff’s Recommendation Forward this petition to the Board of County Commissioners with a recommendation for approval. Staff Tom Reetz, Planner II Tel 772-462-2399 Email ReetzT@stlucieco.org Mail 2300 Virginia Avenue Public Hearing Notice Thursday, July 18, 2024 Proposed Zoning Atlas Amendment Notice of Proposed Amendment to the Official Zoning Atlas for (Rezoning) Guettler Brothers Construction Project Description The petitioners have requested a change in zoning from the IX, In- dustrial Extraction Zoning district to the IL, Industrial Light and IH, Industrial Heavy zoning districts for a property consisting of +/-36 acres, located on the west side of Sapp Road, 1/4 mile south of St. Lucie Boulevard. The petition pro- poses IL for approximately 30 acres, and IH for roughly 6 acres at the northwest corner of the property. Background The parcel is located in the Airport Overlay zone, with a Future Land Use Map designation of Industrial. The property is located in an area with existing industrial uses and industrial future land use/zoning. Staff has concluded that the re- quested change in zoning is not in conflict with the Land Develop- ment Code and Comprehensive Plan and recommends approval. Further details are available in the Planning and Development Services Department—please contact: Planning & Development Services Planning Division, Ph. # 772-462-2822 The St. Lucie County Planning and Zon- ing Commission has the power to review and recommend to the St. Lucie County Board of County Commissioners, for approval or disapproval, any applica- tions within their area of responsibility. The Planning and Zoning Commission strongly encourages your input and comment at the public hearing. You may also mail or email written comments regarding this proceeding in advance of the public hearing for inclusion in the official record. Written comments to the Planning and Zoning Commission should be received by the Planning and Development Services Department—Planning Division at least 3 days prior to the scheduled hearing. Anyone with a disability requiring ac- commodations to attend this meeting may contact the SLC Community Risk Manager at least 48 hours in advance at 772.462.1546 or TDD 772.462.1428 Location: BOCC Chambers SLC Administration Annex, 2300 Virginia Avenue, Fort Pierce, FL 34979 John Doe 123 Anywhere St. Anywhere, USA 12345 Meeting Time: 6:00 PM (or soon thereafter ) PLANNING AND ZONING COMMISSION Insert Star Map—Location Page 403 of 428 ParcelID CuO1LastName CuO1FirstName 1431-701-0007-000-8 Albury Sr Geoffrey P 1431-801-0203-000-9 Alford Family LLC 1432-700-0019-000-5 Allen Debra Wheeler 1431-801-0215-000-6 Anderson Willie M 1432-700-0017-000-1 Banks Jr Trevor 1431-701-0004-000-7 Baret Axene 1431-801-0208-000-4 Beckford Vincent 1431-801-0187-000-0 Bennett Kenneth A 1431-114-0001-000-4 BETKOR PROPERTIES LLC 1431-112-0001-000-8 Betkor Properties Llc 1431-801-0160-000-5 Bowe Kenneth 1432-222-0002-000-6 Calico Amalgamated Properties LLC 1431-801-0189-000-4 Castro Flores Ramon 1432-700-0018-000-8 Cooper Gennifer A 1432-700-0016-000-4 Davidson III Ernest C 1431-701-0001-000-6 Davis (LF EST)Mamie M 1431-701-0107-000-9 Duval Edwina W 1432-321-0050-000-1 East Florida District Primitive Baptist Assc Inc 1431-222-0010-000-2 FPFWCD 1431-801-0146-000-1 Hamilton Toussaint 1431-701-0003-000-0 Hixson Doug 1431-801-0175-000-3 Just Holding Corp 1431-801-0219-000-4 Lazarre Ermith 1431-131-0000-000-0 Lloyd F Bell Jr Revocable Trust of 2011 1431-120-0000-000-6 Maverick Boat Group Inc 1431-111-0020-000-4 MPP ST LUCIE BLVD LLC 1432-322-0026-000-7 New Beginnings Ministries 1431-801-0174-000-6 Oliveira`s Property Mgmt LLC 1432-231-0001-000-7 Revson Jr Charles H 1431-801-0224-000-2 Richardson Sr Calvin C 1431-801-0158-000-8 Robinson James H 1431-801-0210-000-1 Scott Willie G 1431-801-0218-000-7 Summerlin James 1431-140-0000-000-8 TDC Holdings LLC 1431-801-0214-000-9 The AC Trust 1431-801-0212-000-5 Vero Atlantic 2 LLC 1431-801-0204-000-6 Williams Wanda C 1431-801-0220-000-4 Winder VI LLC 1431-801-0213-000-2 Yearby James Page 404 of 428 CuO2LastName CuO2FirstName CuOStreet1 CuOStreet2 CuOCity 4604 Matanzas AVE Fort Pierce 2214 N 45th ST Fort Pierce 2313 Jo Haywood Dr Fort Pierce 2500 N 43rd St Fort Pierce Banks Dana 2316 Jo Haywood DR Fort Pierce 5564 NW Cruzan AVE Port St Lucie Beckford Lizenar 2503 N 44th St Fort Pierce Bennett Vivian C 2409 N 44th St Fort Pierce 13860 Wellington TRCE # 38-204 Wellington 4451 Saint Lucie Blvd Fort Pierce 2412 N 43rd ST Fort Pierce SAPP-11 LLC 284 S Island Golden Beach Castro Jr Ramon L 4401 Matanzas AVE Fort Pierce 2315 Jo Haywood Dr Fort Pierce 2314 Jo Haywood Dr Fort Pierce 4502 Matanzas AVE Fort Pierce 4501 Matanzas Ave Fort Pierce PO Box 819 Fort Pierce 14666 Orange AVE Fort Pierce 1951 SW Gourmet ST Port St Lucie 1144 S Ocean DR Apt D Fort Pierce 7740 NW 47th St Lauderhill 3406 Menendez AVE Fort Pierce 1008 Highway 98 E Unit B Destin 3207 Industrial 29th ST Fort Pierce 2675 S Brocksmith RD Fort Pierce PO Box 3078 Fort Pierce 1658 NE 183rd St North Miami Revson III Charles H 125 Weaver St Greenwich 720 Delaware AVE Ste G Fort Pierce 2413 N 41st ST Fort Pierce Scott Gloria 1509 W 17th St Riviera Beach 220 Hunt AVE Fort Pierce PO Box 15280 Fort Pierce 978 Hacienda CIR Kissimmee 1401 Highway A1A Ste 202 Vero Beach Lennon Areen L 2502 N 45th ST Fort Pierce 18305 Biscayne BLVD Ste 400 Aventura Prowett Kim J 2501 N 43rd ST Fort Pierce Page 405 of 428 CuOState CuOPostal FL 34946 FL 34946 FL 34946 FL 34946 FL 34946 FL 34986-3914 FL 34946 FL 34946 FL 33414 FL 34946 FL 34946 FL 33160 FL 34946 FL 34946 FL 34946 FL 34946 FL 34946 FL 34954 FL 34945 FL 34953 FL 34949 FL 33351 FL 34947 FL 32541 FL 34946-8642 FL 34945 FL 34948 FL 33179 CT 6831 FL 34950 FL 34946 FL 33404 FL 34946 FL 34979 FL 34741 FL 32963 FL 34946 FL 33160 FL 34946 Page 406 of 428 Page 407 of 428 Page 408 of 428 Page 409 of 428 Page 410 of 428 Created: 2023-09-01 19:47:27 [EST] (Supp. No. 25) Page 1 of 10 3.01.03. Zoning Districts. V.IX INDUSTRIAL, EXTRACTION. 1.Purpose. The purpose of this district is to provide and protect an environment suitable for the extraction of natural resources from the ground, together with such other uses as may be necessary to and compatible with industrial extraction surroundings. The number in "( )" following each identified use corresponds to the SIC Code reference described in Section 3.01.02(B). The number 999 applies to a use not defined under the SIC Code but may be further defined in Section 2.00.00 of this Code. 2.Permitted Uses: a. Mining and quarrying of nonmetallic minerals, except fuels. (14) b. Mobile food vendors. (999) 3.Lot Size Requirements. Lot size requirements shall be in accordance with Section 7.04.00. 4.Dimensional Regulations. Dimensional requirements shall be in accordance with Section 7.04.00. 5.Off-Street Parking and Loading Requirements. Off-street parking and loading requirements are subject to Section 7.06.00. 6.Landscaping Requirements. Landscaping requirements are subject to Section 7.09.00. 7.Conditional Uses: a. Telecommunication towers - subject to the standards of Section 7.10.23. (999) 8.Accessory Uses. Accessory uses are subject to the requirements of Section 8.00.00, and include the following: a. Detached single-family dwelling unit or mobile home, for on-site security purposes. (999) T.IL INDUSTRIAL, LIGHT. 1.Purpose. The purpose of this district is to provide and protect an environment suitable for light manufacturing, wholesale, and warehousing activities that do not impose undesirable noise, vibration, odor, dust, or other offensive effects on the surrounding are, together with such other uses as may be necessary to and compatible with light industrial surroundings. The number in "( )" following each identified use corresponds to the SIC Code reference described in Section 3.01.02(B). The number 999 applies to a use not defined under the SIC Code but may be further defined in Section 2.00.00 of this Code. 2.Permitted Uses: a. Business services. (73) b. Communications - including telecommunication towers - subject to the standards of Section 7.10.23. (48) c. Construction services: (1) Building construction - general contractors. (15) (2) Other construction - general contractors. (16) (3) Construction - special trade contractors. (17) d. Engineering, architectural and surveying services. (871) e. Commercial fishing. (091) Page 411 of 428 Created: 2023-09-01 19:47:27 [EST] (Supp. No. 25) Page 2 of 10 f. Laundry, cleaning and garment services. (721) g. Local and suburban transit. (41) h. Manufacturing: (1) Food and kindred products. (20) (2) Tobacco products. (21) (3) Textile mill products. (22) (4) Apparel and other finished products. (23) (5) Furniture and fixtures. (25) (6) Printing, publishing and allied industries. (27) (7) Drugs. (283) (8) Leather and leather products. (31) (9) Glass: (a) Flat glass. (321) (b) Glass and glassware - pressed or blown. (322) (c) Glass products - made of purchased glass. (323) (10) Fabricated metal prod. - except machinery and transport. equip.: (a) Metal cans and shipping containers. (341) (b) Cutlery, handtools and general hardware. (342) (c) Heating equipment, except electric and warm air, and plumbing fixtures. (343) (d) Fabricated structural metal products. (344) (e) Coating, engraving and allied services. (347) (f) Miscellaneous fabricated metal products: (1) Wire products. (3495) (2) Misc. fabricated wire products. (3496) (3) Metal foil and leaf. (3497) (4) Fabricated metal products - NEC. (3499) (11) Industrial/commercial machinery and computer equipment: (a) Metalworking machinery and equipment. (354) (b) Special industry machinery, except metalworking machinery. (355) (c) General industrial machinery and equipment. (356) (d) Computers and office equipment. (357) (12) Electronic and other electrical equipment and components, except computer equipment: (a) Household appliances. (363) (b) Electric lighting and wiring equipment. (364) Page 412 of 428 Created: 2023-09-01 19:47:27 [EST] (Supp. No. 25) Page 3 of 10 (c) Household audio and video equipment. (365) (d) Communications equipment. (366) (e) Electronic components and accessories. (367) (f) Misc. electrical machinery equipment and supplies. (369) (13) Measuring, analyzing and controlling instruments. (38) (14) Photographic, medical and optical goods. (38) (15) Watches and clocks. (38) (16) Misc. manufacturing industries: (a) Jewelry, silverware, and platedware. (391) (b) Musical instruments and parts. (393) (c) Dolls, toys, games and sporting goods. (394) (d) Pens, pencils, and other office and artists' materials. (395) (e) Costume jewelry, costume novelties, and notions. (396) (f) Brooms and brushes. (3991) (g) Signs and advertising displays. (3993) (h) Morticians goods. (3995) (i) Manufacturing industries, NEC. (3999) (17) Plastic products - fabrication, molding, cutting, extrusion, and injection processing. (308) i. Marinas. (4493) j. Millwork and structural wood members. (243) k. Motion pictures. (78) l. Motor freight transportation and warehousing. (42) m. Repair services: (1) Automotive and automotive parking. (75) (2) Electrical. (762) (3) Watch, clock and jewelry repair. (763) (4) Reupholstery and furniture repair. (764) (5) Misc. repairs and services. (769) n. Retail trade: (1) Lumber and other building materials. (521) (2) Paint, glass and wallpaper. (523) (3) Hardware. (525) (4) Nurseries, lawn and garden supplies. (526) (5) Mobile home dealers. (527) Page 413 of 428 Created: 2023-09-01 19:47:27 [EST] (Supp. No. 25) Page 4 of 10 (6) Automotive/boat/RV/motorcycle dealers. (55) (7) Gasoline service. (55) (8) Furniture and furnishings. (57) o. Research, development, and testing services. (873) p. Ship, boat building and repairing - less than forty-five (45) feet. (373) q. Sorting, grading and packaging services - citrus/vegetables. (0723) r. Vocational schools. (824) s. Wholesale trade - durable goods: (1) Motor vehicle and automotive equipment. (501) (2) Furniture and home furnishings.(502) (3) Lumber and other building materials. (503) (4) Professional and commercial equipment/supplies. (504) (5) Metals and minerals except petroleum. (505) (6) Electrical goods. (506) (7) Hardware, plumbing and heating equipment, and supplies. (507) (8) Machinery, equipment, and supplies. (508) (9) Misc. durable goods: (a) Sporting and recreational goods. (5091) (b) Toys and hobby goods. (5092) (c) Jewelry, watches, precious stones and metals. (5094) (d) Durable goods NEC. (5099) t. Wholesale trade - nondurable goods: (1) Paper and paper products. (511) (2) Drugs. (512) (3) Dry goods and apparel. (513) (4) Groceries and related products. (514) (5) Farm products - raw materials. (515) (6) Chemicals, and allied products. (516) (7) Beer, wine, and distilled alcoholic beverages. (518) (8) Misc. nondurable goods: (a) Farm supplies. (5191) (b) Books, periodicals and newspapers. (5192) (c) Flowers, nursery stock and florists' supplies. (5193) (d) Tobacco/tobacco products. (5194) Page 414 of 428 Created: 2023-09-01 19:47:27 [EST] (Supp. No. 25) Page 5 of 10 (e) Paints, varnishes and supplies. (5198) (f) Nondurable goods, NEC. (5199) u. Mobile food vendors. (999) v. Single-family detached dwelling units provided that the single-family dwelling unit is located on an existing lot or parcel or record, as further defined in this Code, that was existing on or before August 1, 1990. (999) w. Kennels. Allowed as a permitted use only when the property is surrounded by industrial uses or zoning and is five hundred (500) feet or more from residential uses or zoning. All distance requirements shall be measured from the nearest point of the existing home or area of single- family zoning to the nearest point of the proposed kennel. x. Landscape and horticultural services. (078) y. Personal services. (72) 3.Lot Size Requirements. Lot size requirements shall be in accordance with Table 7-10 in Section 7.04.00. 4.Dimensional Regulations. Dimensional requirements shall be in accordance with Table 7-10 in Section 7.04.00. 5.Offstreet Parking and Loading Requirements. Offstreet parking and loading requirements are subject to Section 7.06.00. 6.Landscaping Requirements. Landscaping requirements are subject to Section 7.09.00. 7.Conditional Uses: a. Airports, landing and takeoff fields - general aviation. (4581) b. Manufacturing: (1) Cut stone and stone products. (328) (2) Motorcycles, bicycles, and parts. (375) (3) Wood containers, wood buildings and mobile homes. (244/245) c. Ship, boat building and repairing (excluding ship or boat salvaging) - forty-five (45) to one hundred fifty (150) feet. (373) d. Wholesale: (1) Petroleum bulk stations and terminals. e. Scrap and waste materials - subject to the provisions of Section 7.10.12.A. f. Kennels. (0752) Other than those permitted under Section 3.01.03 T.2.w. of the Land Development Code. 8.Accessory Uses. Accessory uses are subject to the requirements of Section 8.00.00 and include the following: a. Co-generation facilities. (999) b. Fueling facilities. (999) c. Industrial wastewater disposal. (999) d. One detached single-family dwelling or mobile home for on-site security purposes per property. (999) Page 415 of 428 Created: 2023-09-01 19:47:27 [EST] (Supp. No. 25) Page 6 of 10 e. Retail trade accessory to the primary manufacturing or wholesaling use. (999) f. Solar energy systems, subject to the requirements of Section 7.10.28. g. Cargo containers subject to the requirements of Section 7.10.35. U.IH INDUSTRIAL, HEAVY. 1.Purpose. The purpose of this district is to provide an environment suitable for heavy manufacturing and other activities that may impose undesirable noise, vibration, odor, dust, or other offensive effects on the surrounding area together with such other non-residential uses as may be necessary to and compatible with heavy industrial surroundings. The number in "( )" following each identified use corresponds to the SIC Code reference described in Section 3.01.02(B). The number 999 applies to a use not defined under the SIC Code but may be further defined in Section 2.00.00 of this Code. 2.Permitted Uses. Any use permitted in the Industrial Light (IL) zoning district: a. Agricultural services. (07) b. Construction services: (1) Building construction - general contractors. (15) (2) Other construction - general contractors. (16) (3) Construction - special trade contractors. (17) c. Docks and boathouses (private). (999) d. Engineering services. (871) e. Manufacturing: (1) Food and kindred products. (20) (2) Tobacco products. (21) (3) Textile mill products. (22) (4) Apparel and other finished products. (23) (5) Lumber and wood products, except furniture. (24) (6) Furniture and fixtures. (25) (7) Printing and publishing and allied industries. (27) (8) Chemicals and allied products: (a) Drugs. (283) (b) Soap, detergents and cleaning preparations; perfumes, cosmetics and other toilet preparations. (284) (c) Agricultural chemicals. (287) (9) Rubber and misc. plastic products. (30) (10) Leather and leather products. (31) (11) Glass: (a) Flat glass. (321) (b) Glass and glassware - pressed or blown. (322) Page 416 of 428 Created: 2023-09-01 19:47:27 [EST] (Supp. No. 25) Page 7 of 10 (c) Glass products - made of purchased glass. (323) (12) Fabricated metal products (except ammunition and ordnance). (34) (13) Industrial/commercial machinery and computer equipment. (35) (14) Electronic and other electrical equipment and components, except computer equipment. (36) (15) Transportation equipment. (37) (16) Measuring, analyzing and controlling instruments. (38) (17) Misc. manufacturing industries: (a) Jewelry, silverware, and plated ware. (391) (b) Musical instruments and parts. (393) (c) Dolls, toys, games and sporting goods. (394) (d) Pens, pencils and other office and artists' materials. (395) (e) Costume jewelry, costume novelties, and notions. (396) (f) Brooms and brushes. (3991) (g) Signs and advertising displays. (3993) (h) Morticians goods. (3995) (i) Manufacturing industries, NIC. (3999) (18) Paper and allied products: (a) Paperboard containers and boxes. (265) (b) Converted paper and paperboard products. (267) f. Local and suburban transit. (41) g. Water transportation. (44) h. Transportation services. (47) i. Communications. (48) j. Motor freight transportation and warehousing. (42) k. Motion pictures. (78) l. Membership organizations. (86) m. Personal and business services. (72) n. Research, development, and testing services. (873) o. Repair services: (1) Automotive and automotive parking. (75) (2) Electrical. (762) (3) Watch, clock and jewelry repair. (763) (4) Reupholstery and furniture repair. (764) Page 417 of 428 Created: 2023-09-01 19:47:27 [EST] (Supp. No. 25) Page 8 of 10 (5) Misc. repairs and services. (769) p. Retail trade: (1) Lumber and other building materials. (521) (2) Paint, glass and wallpaper. (523) (3) Hardware. (525) (4) Nurseries, lawn and garden supplies. (526) (5) Mobile home dealers. (527) (6) Automotive/boat/RV/motorcycle dealers. (55) (7) Gasoline service. (55) (8) Furniture and furnishings. (57) q. Telecommunication towers - subject to the standards of Section 7.10.23. (999) r. Wholesale trade - durable goods: (1) Motor vehicle and automotive equipment. (501) (2) Furniture and home furnishings. (502) (3) Lumber and other building materials. (503) (4) Professional and commercial equipment/supplies. (504) (5) Metals and minerals, except petroleum. (505) (6) Electrical goods. (506) (7) Hardware, plumbing and heating equipment, and supplies. (507) (8) Machinery, equipment, and supplies. (508) (9) Misc. durable goods: (a) Sporting and recreational goods. (5091) (b) Toys and hobby goods. (5092) (c) Jewelry, watches, precious stones and metals. (5094) (d) Durable goods NEC. (5099) s. Wholesale trade - nondurable goods: (1) Paper and paper products. (511) (2) Drugs. (512) (3) Dry goods and apparel. (513) (4) Groceries and related products. (514) (5) Farm products - raw materials. (515) (6) Chemicals, and allied products. (516) (7) Beer, wine, and distilled alcoholic beverages. (518) (8) Misc. nondurable goods: Page 418 of 428 Created: 2023-09-01 19:47:27 [EST] (Supp. No. 25) Page 9 of 10 (a) Farm supplies. (5191) (b) Books, periodicals, and newspapers. (5192) (c) Flowers, nursery stock and florists' supplies. (5193) (d) Tobacco/tobacco products. (5194) (e) Paints, varnishes and supplies. (5198) (f) Nondurable goods, NEC. (5199) t. Mobile food vendors. (999) 3.Lot Size Requirements. Lot size requirements shall be in accordance with Section 7.04.00. 4.Dimensional Regulations. Dimensional requirements shall be in accordance with Section 7.04.00. 5.Offstreet Parking and Loading Requirements. Offstreet parking and loading requirements are subject to Section 7.06.00. 6.Landscaping Requirements. Landscaping requirements are subject to Section 7.09.00. 7.Conditional Uses: a. Airport, landing and takeoff fields - general aviation. (4581) b. Manufacturing: (1) Paper and allied products. (26) (2) Chemicals and allied products. (28) (3) Petroleum refining and related products. (29) (4) Stone, clay, glass and concrete products. (32) (5) Primary metal industries. (33) (6) Ammunition and ordinance. (348) c. Natural or manufactured gas storage and distribution points. (492) d. Scrap, waste and land clearing and yard trash recycling operations - subject to the provisions of Section 7.10.12. e. Warehousing and storage services - stockyards. (999) f. Wholesale trade - nondurable goods: (1) Petroleum and petroleum products. (999) 8.Accessory Uses. Accessory uses are subject to the requirements of Section 8.00.00, and include the following: a. Co-generation facilities. (999) b. Fueling facilities. (999) c. Industrial wastewater disposal. (999) d. One (1) detached single-family dwelling or mobile home, for on-site security purposes per property. (999) e. Retail: Page 419 of 428 Created: 2023-09-01 19:47:27 [EST] (Supp. No. 25) Page 10 of 10 (1) Bottled gas. (999) (2) Fuel oil. (999) (3) Gasoline service stations. (999) (4) Retail trade accessory to the primary manufacturing or wholesaling use. (999) f. Solar energy systems, subject to the requirements of Section 7.10.28. g. Cargo containers subject to the requirements of Section 7.10.35 Page 420 of 428 FUTURE LAND USE ELEMENT GOALS, OBJECTIVES AND POLICIES Goal 1.1: Ensure the highest quality living environment possible, through a mixture of land uses reflecting the needs and desires of the local residents and how they want their community to develop. The goal shall be implemented by strictly enforced building, zoning and development codes based on objectives and policies that will enhance St. Lucie County's natural and man-made resources while minimizing any damage or threat of degradation to the health, safety and welfare of the county's citizens, native wildlife and environment, through incompatible land uses. Objective 1.1.1: Land Use. Maintain the Future Land Use Map land with the following use designations to portray the future development patterns of St. Lucie County. Policy 1.1.1.1 - The following land use designations/intensities, as indicated on the Future Land Use Maps are provided as the pattern for the future development of the area within unincorporated St. Lucie County. Future Land Use Designation Residential Density Max Height4 (For Buildings) Max Lot Coverage (For Buildings) AG-5 Agriculture-5 1 du/5 acres (0.2 du/1 acre) - - AG-2.5 Agriculture-2.5 1 du/2.5 acres (0.4 du/1 acre) - - RE Residential Estate 1 du/a acre - - RS Residential Suburban 2 du/1 acre - - RU Residential Urban 5 du/1 acre - - RM Residential Medium 9 du/ 1 acre - - RH Residential High 15 du/ 1 acre - - R/C Residential/Conservation 1 du/5 acres (0.2 du/1 acre) - - Cpub Conservation-Public 0 du1 20 ft 5-10% COM Commercial 0 du1.5 60 ft3 40—50% IND Industrial 0 du1 80 ft 40—50% P/F Public Facilities 0 du1 80 ft 40—50% T/U Transportation/Utilities 0 du1 40 ft6 40—50% MXD Mixed Use Development 0.2-15 du/acre2.5 80 ft 40—50% H Historic 0 du1 40 ft 40—50% SD Special District 0.2-15 du/acre 80 ft 40—50% TVC Towns, Villages, & Countryside Variable pursuant to special areas plan. See TVC Element Goals, Objectives, and Policies. 1-9 du/acre - - Notes: 1 Residential uses permitted under specific conditions only. Refer to Zoning/Land Development Code for special restrictions in individual zoning districts. 2 Maximum Densities subject to compliance with intensity with intensity plans for each mixed use area, as set forth in Policy 1.1.8.4 3 For motel or hotel uses, the building spacing formula as identified in the Land Development Code shall be used to establish maximum building height, unless otherwise stipulated in the Hutchinson Island Building Height Overlay Zone section of the Land Development Code, or unless otherwise restricted by Code or Ordinance of the County. 4 Unless otherwise stipulated in the Hutchinson Island Height Overlay Zone section in the Land Development Code 5 Motels/hotels shall be allowed up to 36 units/acre. 6 The height of the Treasure Coast Airport shall be regulated by the Airport Zone Height Limitations established in Section 4.00.03, of the Land Development Code, as reviewed and approved by the Federal Aviation Administration (FAA). Page 421 of 428 St. Lucie County 1-4 Adopted_updated 12.2022 Comprehensive Plan Future Land Use Element GOPs J. Commercial (COM) The Commercial (COM) land use designation is applicable to areas of future commercial development, in addition to those existing developed commercial areas. Future commercial areas should be located at points of high transportation access, with specific action taken to prevent the development of new linear commercial strips. Although this plan supports the location of higher intensity commercial uses at the intersection of arterial roadways, it should not be interpreted to mean that every intersection should be designated for commercial activities. Unless otherwise designated on the future land use maps, applications for commercial use should be done in conjunction with a detailed review of the impacts of such development on adjacent property, specifically noting what, if any, negative neighborhood impacts could result from a map amendment. The Commercial (COM) designation is intended to accommodate all commercial zoning districts as identified under St. Lucie County's Land Development Code. Office and general retail uses are considered the principal uses within the COM designated areas. K. Industrial (IND) This land use designation is applied to specific areas of the County identified as suitable for industrial use. This land use designation is intended to be implemented through both the heavy and light industrial zoning districts, with the specific criteria for zoning application as provided for under the policies of the Future Land Use Element. Areas designated for Industrial activities must have available all necessary services and facilities prior to development, supplied by either public or private sources as permitted. In addition, developments proposing to incorporate heavy industrial uses will be required to be adequately buffered from any adjacent use that would be incompatible. Limited nonresidential uses may be appropriate, in accordance with applicable standards and restrictions as set forth in the Land Development Code. L. Public Facilities (P/F) The Public Facilities (P/F) land use designation is applied to properties used for such activities as education and places of worship. This designation may also be applied to other public uses such as jails and administrative buildings. M. Transportation/Utilities (T/U) The purpose of this district is to recognize the Transportation or Utility use of property. This designation may be applied as appropriate subject to review of the specific application and intended use of the property. The Transportation/Utilities (T/U) land use designation has been applied principally to four areas: 1) Treasure Coast International Airport; 2) The St. Lucie County Landfill; 3) The St. Lucie Power Plant site located on South Hutchinson Island; and, 4) The Florida Power and Light-Midway switching station along West Midway Road. N. Historic (H) The Historic (H) land use designation is applied to properties of historic significance as identified by the national historic register, the State of Florida or local designation. Page 422 of 428 LEGAL DESCRIPTION A PARCEL OF LAND FOR REZONING, LYING IN A PORTION OF PARCEL IDENTIFICATION NUMBER 1431-140-0000-000-8, RECORDED IN OFFICIAL RECORD BOOK 3090, PAGE 547, LYING IN SECTION 31, TOWNSHIP 34 SOUTH, RANGE 40 EAST, ST. LUCIE COUNTY, FLORIDA. SAID PARCEL OF LAND FOR REZONING BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS: COMMENCING AT THE NORTHEAST CORNER OF SAID SECTION 31; THENCE ALONG THE EAST LINE OF THE NORTHEAST QUARTER OF SAID SECTION 31, SOUTH 00°11'27" WEST, A DISTANCE OF 1333.36 FEET; THENCE DEPARTING FROM SAID SECTION LINE AND ALONG THE NORTH LINE OF THE SOUTHEAST QUARTER OF THE NORTHEAST QUARTER OF SAID SECTION 31, NORTH 89°48'10" WEST, A DISTANCE OF 30.00 FEET TO THE NORTHEAST BOUNDARY CORNER OF SAID PARCEL, AS RECORDED IN OFFICIAL RECORD BOOK 3090, PAGE 547, SAID POINT ALSO BEING THE POINT OF BEGINNING; THENCE DEPARTING FROM SAID QUARTER SECTION LINE AND ALONG THE WESTERLY RIGHT OF WAY LINE OF SAPP ROAD AS RECORDED IN OFFICIAL RECORD BOOK 155, PAGE 53, ST LUCIE COUNTY, FLORIDA, SOUTH 00°11'27" WEST, A DISTANCE OF 1205.32 FEET TO THE SOUTHEAST BOUNDARY CORNER OF SAID PARCEL; THENCE ALONG THE NORTH RIGHT OF WAY LINE OF CANAL NO. 1, NORTH 89°49'01" WEST, A DISTANCE OF 1303.41 FEET TO A POINT ON THE WEST LINE OF THE SOUTHEAST QUARTER OF THE NORTHEAST QUARTER OF SAID SECTION 31 SAID POINT ALSO BEING THE SOUTHEAST BOUNDARY CORNER OF SAID PARCEL; THENCE DEPARTING SAID NORTH RIGHT OF WAY LINE AND ALONG SAID QUARTER SECTION LINE, NORTH 00°10'14" EAST, A DISTANCE OF 710.32 FEET; THENCE DEPARTING SAID QUARTER SECTION LINE, SOUTH 89°48'10" EAST, A DISTANCE OF 663.66 FEET; THENCE NORTH 00°11'27" EAST, A DISTANCE OF 495.32 FEET TO A POINT ON SAID NORTH LINE OF THE SOUTHEAST QUARTER OF THE NORTHEAST QUARTER OF SAID SECTION 31; THENCE ALONG SAID NORTH QUARTER SECTION LINE, SOUTH 89°48'10" EAST, A DISTANCE OF 640.00 FEET TO THE POINT OF BEGINNING. SAID PARCEL OF LAND FOR REZONING CONTAINING WITHIN SAID BOUNDS 1,242,725 SQUARE FEET (28.53 ACRES) MORE OR LESS. EXHIBIT __ PAGE 1 OF 2 NOT VALID WITHOUT PAGE 2 OF 2 N/A 1 OF 2 DATE: SCALE: G-S DRAWN BY: N/A FIELD BOOK/PAGES F.N.G.APPROVED BY: -OB NR.: 22-1008 07-01-24 SHEET: DATE:BY:REVISIONS 1449 NW COMMERCE CENTRE DR PORT ST. LUCIE, FL 34986 PHONE: (772) 879-0477 CERTIFICATE OF AUTHORIZATION NO. LB 8206 ENGINEERING & SURVEYING, LLC. VELCONVELCON SKETCH AND LEGAL DESCRIPTION PREPARED FOR FOR DARREN GUETTLER Page 423 of 428 SKETCH OF DESCRIPTIONLEGEND PG R/W (POB) = PAGE = RIGHT OF WAY = POINT OF BEGINNING (POC)= POINT OF COMMENCEMENT BEARINGS SHOWN HEREON ARE BASED UPON A GRID NORTH BEARING ALONG THE EAST LINE OF THE NE 1/4 OF SECTION 31, SAID BEARING BEING S 00°11'27" W. ALL OTHER BEARINGS ARE RELATIVE THERETO. NOT VALID WITHOUT THE ORIGINAL SIGNATURE AND RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER NOT VALID WITHOUT PAGE 1 OF 2. THIS IS NOT A BOUNDARY SURVEY. ORB = OFFICIAL RECORD BOOK E = EASTING SF = SQUARE FEET 30.0' 12 5 . 0 ' 12 5 . 0 ' EA S T L I N E O F T H E N E 1 / 4 O F S E C T I O N 3 1 SOUTH LINE OF THE NE 1/4 OF SECTION 31 S 0 0 ° 1 1 ' 2 7 " W 13 3 3 . 3 6 ' SKETCH AND LEGAL DESCRIPTION PREPARED FOR FOR DARREN GUETTLER 1" = (SCALE IN FEET) GRAPHIC SCALE 0400 400 800 400' 200 (POC) NORTHEAST CORNER SECTION 31, TOWNSHIP 34 SOUTH, RANGE 40 EAST ST LUCIE COUNTY, FLORIDA SA P P R O A D OR B 1 5 5 , P G 5 3 (6 0 ' R / W ) ST LUCIE BOULEVARD (80' R/W) (POB) NE BOUNDARY CORNER OF PARCEL N: 1144331.83 E: 861676.92 (B A S I S O F B E A R I N G S ) NORTH LINE OF THE NE 1/4 SECTION 31 WE S T E R L Y R / W L I N E O F S A P P R O A D FDOT RIGHT OF WAY MAP SECTION NO. 9460-1 FDOT = FLORIDA DEPARTMENT OF TRANSRPORTATION ID = IDENTIFICATION N: 1145665.08 E: 861711.36 N 89°49'01" W 1303.41' N 0 0 ° 1 0 ' 1 4 " E 71 0 . 3 2 ' PARCEL ID: 1431-131-0000-000-0 ORB 3504, PG 831 FORT PIERCE FARMS DRAINAGE DISTRICT CANAL NO.1 PARCEL ID: 1431-222-0010-000-2 (240' R/W) PARCEL ID: 1431-120-0000-000-6 ORB 3981, PG 2141 PARCEL ID: 1431-112-0001-000-8 ORB 1335, PG 2036 PARCEL ID: 1431-114-0001-000-4 ORB 4737, PG 814 PARCEL ID: 1432-231-0002-000-4 ORB 4405, PG 73 N 89°48'10" W 30.00' FRANCIS N. GUETTLER STATE OF FLORIDA (PSM)7473 PROFESSIONAL SURVEYOR AND MAPPER 1" = 400' 2 OF 2 DATE: SCALE: G-S DRAWN BY: N/A FIELD BOOK/PAGES F.N.G. APPROVED BY: -OB NR.: 22-1008 07-01-24 SHEET: DATE:BY:REVISIONS 1449 NW COMMERCE CENTRE DR PORT ST. LUCIE, FL 34986 PHONE: (772) 879-0477 CERTIFICATE OF AUTHORIZATION NO. LB 8206 ENGINEERING & SURVEYING, LLC. VELCONVELCON NO R T H N 0 0 ° 1 1 ' 2 7 " E 49 5 . 3 2 ' S 89°48'10" E 663.66' S 89°48'10" E 640.00' PARCEL ID: 1431-140-0000-000-8 ORB 3090, PG 547 SOUTHERLY R/W LINE WE S T L I N E O F T H E S E 1 / 4 OF T H E N E 1 / 4 O F S E C T I O N 3 1 NORTH LINE OF THE SE 1/4 OF THE NE 1/4 OF SECTION 31 EAST 1/4 CORNER SECTION 31, TOWNSHIP 34 SOUTH, RANGE 40 EAST, ST LUCIE COUNTY, FLORIDA PROPOSED REZONING LIGHT INDUSTRIAL 1,242,725 SF OR 28.53 ACRES ±. NORTH LINE CANAL NO. 1 N = NORTHING NO.= NUMBER S 0 0 ° 1 1 ' 2 7 " W 12 0 5 . 3 2 ' SW BOUNDARY CORNER OF PARCEL SE BOUNDARY CORNER OF PARCEL Page 424 of 428 LEGAL DESCRIPTION A PARCEL OF LAND FOR REZONING, LYING IN A PORTION OF PARCEL IDENTIFICATION NUMBER 1431-140-0000-000-8, RECORDED IN OFFICIAL RECORD BOOK 3090, PAGE 547, LYING IN SECTION 31, TOWNSHIP 34 SOUTH, RANGE 40 EAST, ST. LUCIE COUNTY, FLORIDA. SAID PARCEL OF LAND FOR REZONING BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS: COMMENCING AT THE NORTHEAST CORNER OF SAID SECTION 31; THENCE ALONG THE EAST LINE OF THE NORTHEAST QUARTER OF SAID SECTION 31, SOUTH 00°11'27" WEST, A DISTANCE OF 1333.36 FEET; THENCE DEPARTING FROM SAID SECTION LINE AND ALONG THE NORTH LINE OF THE SOUTHEAST QUARTER OF THE NORTHEAST QUARTER OF SAID SECTION 31, NORTH 89°48'10" WEST, A DISTANCE OF 670.00 FEET TO THE POINT OF BEGINNING; THENCE DEPARTING FROM SAID QUARTER SECTION LINE, SOUTH 00°11'27" WEST, A DISTANCE OF 495.32 FEET; THENCE NORTH 89°48'10" WEST, A DISTANCE OF 663.66 FEET TO A POINT ON THE WEST LINE OF THE SOUTHEAST QUARTER OF THE NORTHEAST QUARTER OF SAID SECTION 31; THENCE ALONG SAID QUARTER SECTION LINE, NORTH 00°10'14" EAST, A DISTANCE OF 495.32 FEET TO THE NORTHWEST BOUNDARY CORNER OF SAID PARCEL, AS RECORDED IN OFFICIAL RECORD BOOK 3090, PAGE 547; THENCE ALONG SAID NORTH LINE OF THE SOUTHEAST QUARTER OF THE NORTHEAST QUARTER OF SAID SECTION 31, SOUTH 89°48'10" EAST, A DISTANCE OF 663.83 FEET TO THE POINT OF BEGINNING. SAID PARCEL OF LAND FOR REZONING CONTAINING WITHIN SAID BOUNDS 328,769 SQUARE FEET (7.55 ACRES) MORE OR LESS. EXHIBIT __ PAGE 1 OF 2 NOT VALID WITHOUT PAGE 2 OF 2 N/A 1 OF 2 DATE: SCALE: G-S DRAWN BY: N/A FIELD BOOK/PAGES F.N.G.APPROVED BY: -OB NR.: 22-1008 07-01-24 SHEET: DATE:BY:REVISIONS 1449 NW COMMERCE CENTRE DR PORT ST. LUCIE, FL 34986 PHONE: (772) 879-0477 CERTIFICATE OF AUTHORIZATION NO. LB 8206 ENGINEERING & SURVEYING, LLC. VELCONVELCON SKETCH AND LEGAL DESCRIPTION PREPARED FOR FOR DARREN GUETTLER Page 425 of 428 SKETCH OF DESCRIPTIONLEGEND PG R/W (POB) = PAGE = RIGHT OF WAY = POINT OF BEGINNING (POC)= POINT OF COMMENCEMENT BEARINGS SHOWN HEREON ARE BASED UPON A GRID NORTH BEARING ALONG THE EAST LINE OF THE NE 1/4 OF SECTION 31, SAID BEARING BEING S 00°11'27" W. ALL OTHER BEARINGS ARE RELATIVE THERETO. NOT VALID WITHOUT THE ORIGINAL SIGNATURE AND RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER NOT VALID WITHOUT PAGE 1 OF 2. THIS IS NOT A BOUNDARY SURVEY. ORB = OFFICIAL RECORD BOOK E = EASTING SF = SQUARE FEET 30.0' 12 5 . 0 ' 12 5 . 0 ' EA S T L I N E O F T H E N E 1 / 4 O F S E C T I O N 3 1 SOUTH LINE OF THE NE 1/4 OF SECTION 31 S 0 0 ° 1 1 ' 2 7 " W 13 3 3 . 3 6 ' SKETCH AND LEGAL DESCRIPTION PREPARED FOR FOR DARREN GUETTLER 1" = (SCALE IN FEET) GRAPHIC SCALE 0400 400 800 400' 200 (POC) NORTHEAST CORNER SECTION 31, TOWNSHIP 34 SOUTH, RANGE 40 EAST ST LUCIE COUNTY, FLORIDA SA P P R O A D OR B 1 5 5 , P G 5 3 (6 0 ' R / W ) ST LUCIE BOULEVARD (80' R/W) (POB) N: 1144334.04 E: 861036.92 (B A S I S O F B E A R I N G S ) NORTH LINE OF THE NE 1/4 SECTION 31 WE S T R / W L I N E O F S A P P R O A D FDOT RIGHT OF WAY MAP SECTION NO. 9460-1 FDOT = FLORIDA DEPARTMENT OF TRANSRPORTATION ID = IDENTIFICATION N: 1145665.08 E: 861711.36 N 89°48'10" W 670.00'N 0 0 ° 1 0 ' 1 4 " E 49 5 . 3 2 ' PARCEL ID: 1431-131-0000-000-0 ORB 3504, PG 831 FORT PIERCE FARMS DRAINAGE DISTRICT CANAL NO.1 PARCEL ID: 1431-222-0010-000-2 (240' R/W) PARCEL ID: 1431-120-0000-000-6 ORB 3981, PG 2141 PARCEL ID: 1431-112-0001-000-8 ORB 1335, PG 2036 PARCEL ID: 1431-114-0001-000-4 ORB 4737, PG 814 PARCEL ID: 1432-231-0002-000-4 ORB 4405, PG 73 FRANCIS N. GUETTLER STATE OF FLORIDA (PSM)7473 PROFESSIONAL SURVEYOR AND MAPPER 1" = 400' 2 OF 2 DATE: SCALE: G-S DRAWN BY: N/A FIELD BOOK/PAGES F.N.G. APPROVED BY: -OB NR.: 22-1008 07-01-24 SHEET: DATE:BY:REVISIONS 1449 NW COMMERCE CENTRE DR PORT ST. LUCIE, FL 34986 PHONE: (772) 879-0477 CERTIFICATE OF AUTHORIZATION NO. LB 8206 ENGINEERING & SURVEYING, LLC. VELCONVELCON NO R T H S 0 0 ° 1 1 ' 2 7 " W 49 5 . 3 2 ' N 89°48'10" W 663.66' S 89°48'10" E 663.83' PARCEL ID: 1431-140-0000-000-8 ORB 3090, PG 547 SOUTHERLY R/W LINE WE S T L I N E O F T H E S E 1 / 4 OF T H E N E 1 / 4 O F S E C T I O N 3 1 NORTH LINE OF THE SE 1/4 OF THE NE 1/4 OF SECTION 31 EAST 1/4 CORNER SECTION 31, TOWNSHIP 34 SOUTH, RANGE 40 EAST, ST LUCIE COUNTY, FLORIDA PROPOSED REZONING HEAVY INDUSTRIAL 328,769 SF OR 7.55 ACRES ±. NW BOUNDARY CORNER OF PARCEL NORTH LINE CANAL NO. 1 N = NORTHING NO.= NUMBER Page 426 of 428 Charles H. Revson, Jr. 125 Weaver Street Greenwich, CT 06831 Dear St. Lucie County Planning and Zoning Commission, I received a public hearing notice for 7/18/24 notifying me of an impending zoning change which has been recommended for approval by Tom Reetz, Planner II. I spoke to Mr. Reetz and Corey Benton. The zoning applicants, the Guettler Bros., indicated to Reetz and Benton that the change in zoning was necessary in order to build offices, truck parking, and a possible asphalt plant with no mention of a landfill. According to Mr. Benton they are possibly planning to close their current office and equipment parking facility which is in a residential area, and move them to this location. The concern that I have is that this is just a first step to try to get approval for a demolition/construction landfill facility. This could be a multi-million dollar business in addition to saving them the cost of dumping their own debris. The property is an abandoned mine 50 feet deep filled with water encompassing over 14 acres which is a PERFECT location for a demolition debris landfill. If this is their plan, it would cause clouds of dust and the disruption and noise of large dump trucks going up and down Sapp road which is a dirt road. To be clear, in talking to Mr. Benton, the applicant has never brought up the question of putting in a landfill. The reason I am questioning the applicants’ intent is that this property makes for a great demolition debris landfill and seemingly not a great site for truck storage, offices, and an asphalt plant. It has a large lake in the middle and distances from the property lines to the lake and its shore are less than 200 feet in some places. As a property owner across Sapp road, I would like the commissioners to ask the applicants point blank in the hearing if they have any interest now or in the future to convert this property to a demolition debris landfill. If they equivocate in any way, a change of zoning to heavy industrial should be Page 427 of 428 denied. Mr. Reetz’s argument that I should not be concerned about a land fill because the heavy industrial zoning would permit demolition debris ONLY on six acres is false.The dumping area of the pond is 14 acres. I am concerned that through some interpretation of the environmental laws that it could be enough, with the heavy industry zoning, to get a land fill on the property in the future. I am only speculating on the intentions of the applicant and am basing my concerns on the unique topography of the subject property. This letter will be in the official record, and my concerns will be noted at the public hearing which I cannot attend. Thank you for your consideration. Should you want to contact me, my email is rever125@aol.com and my phone is 203-532-9209. Sincerely yours, Charles H. Revson, Jr. Page 428 of 428