Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSDATE: OL . FEES _j IJ O �-J RECEIPT #: t Permit #: ` 4:: :: emu. Planning & Development Services Department UVTYBuilding & Code Regulation Division n c 2300 Virginia Avenue 6s�iN " rD Ft. Pierce, FL 34982-5652 13 Tel.772462-1553 St. Lucia county APPLICATION FOR ROOF PERMIT_ SEE REVERSE SIDE FOR INSTRUCTIONS 1. Location/Site Address: 7705 James Rd.. 2. Parcel ID Number: 1301-603-0018-000-7. Office Use Only Section Townshi Range Ma Page ZoningLand Use Initials 3. Description of Project or Work Activity: Remove existing shingles, Dry in, Install new OC Pro 30 Shingles. 4. Total Roof Area (square feet): 2200• 5. Roof Pitch: 3/12. 6. Type of Roof: [¢ ] Fiberglass Shingle [ 1 ] Tar & Gravel [ ] Concrete Roof Tile [ ] Wood Shake / Shingle [ ] Modified Bitumen [ ] Other [ ] Product Approval required for all types of Roofing Material (2 Sets) [ ] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product Approval attached ** Roof Mitigation per F.S. 553.844 will be required. 7. Owner Information 8. Contractor Information Name: Reba Bryan . Address: 7705 James Rd. City: Fort Pierce. Zip: 34951. State: FL. Phone: 465-0270. 9. Value of Construction: $ 6,690. FL Reg/Cert #: CC-0057399 County Cert #: 16414 Business Name: Trade Winds Roofing Inc Cell Phone: 772-466-9420 "Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval. CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in compliancre�w�applicable lating construction and zoning. Michael Miller _ "�' V PRINT QUALIFIERS/OWNERS NAME SI NATURE OF QUALIFIER/OWNER STATE OF FLORIDA, COUNTY OF ACKNOWLEDGED BEFORE ME THIS W DAY OF 20, BY ; der IS PERSONA LL OWN TO ME OR HAS PRODUCED AS IDENTIFICATION �. . 014 "l may A OROTARY Tim,OR PRINT NAME OF NO ARY (seal) COMMISSION NUMBER NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Revised 4/26/2010 _ AUDREY 8. HUMPHREY * MY COMMISSION # EE 061159 EXPIRES: March 6, 2015 Bonded Thru Notary Public Underwriters J `� INSTRUCTIONS Please complete all information in the space provided. All information must be printed (use black or blue ink only) or typed. This roof permit application is to be used only for those activities that are not otherwise included under a primary building permit. This application may not be used for any activity that includes structural alteration. Building activities involving structural alteration, in addition to the roof work, must be permitted through the regular building permit review process. The information to be provided with this application includes: 1. Location/Site Address 2. Parcel ID Number 3. Description of Project or Work Activity 4. Total Roof Area 5. Type of Roof 6. Owner Information 7. Contractor Information 8. Value of Construction Indicate the street address or general location of the property where the building activity is taking place. Indicate the tax identification number of the property where the building activity is taking place. Completely describe the building activity to take place. Please indicate if tear -off or shingle over shingle etc. Indicate total roof area to be affected by this permit. Also indicate the pitch of the roof, expressed as a standard ratio of run rise. Indicate the type of roof being repaired or resurfaced. Indicate the name and address of the owner of the property on which building activity is taking place. Indicate the State of Florida registration number (if applicable), St. Lucie County contractor license number and the name of the business doing the work. Indicate the total value of the work to take place. Total cost of construction includes all material and labor costs associated with the building/construction activity. Construction value is used to detennine the permit fee. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction. This application can be submitted to St. Lucie County Building and Zoning, 2300 Virginia Avenue, Fort Pierce, FL 34982. All permit applications must be filled out completely before submission. No applications will be accepted for processing after 4:30 P.M. For assistance in completing this application, please call (772) 462-1553, during regular office hours (8:00 AM - 5:00 PM), Monday through Friday. Upon issuance of this permit, required inspections can be scheduled by calling (772) 462-1261. St. Lucie County Roof Permit Application rev. 3/1/2009 JOSEPH E. SMITH, CLERK OF THE CIRCUIT COURT — SAINT LUCIE COUNTY FILE # 3671468 OR BG�--e,,3360 PAGE 1641, Recorded 02/06/201,Kl12:51 PM y i PERMIT NUMBER: NOTICE OF COMMENCEMENT The undersigned hereby given notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida statutes the following information is provided in the Notice of commencement. 1. DESCRIPTION OF PROPER al description and street address) TAX FOLIO NUMBER: 1301-603-0018-000-7 SUBDIVISION I akewood � 17 TRACT 18 BLDG UNIT 7705 James Rd, Fort Pierce, FL 34951 2. GENERAL DESCRIPTION OF IMPROVEMENT. reroof 3.OWNER INFORMATION: a. Name Reba M Bryan b. Address 7705 James Rd., Fort Pierce, FL 34951 c. interest in property d. Name and address of fee simple titleholder (if other than owner) 4. CONTRACTOR'S NAME, ADDRESS AND PHONE NUMBER: Trade Winds Roofing, Inc. P.O. Box 13208, Fort Pierce, FL 3,4979 772-466-9420 5. SURETY'S NAME, ADDRESS AND PHONE NUMBER AND BOND AMOUNT: 6. LENDER'S NAME, ADDRESS AND PHONE NUMBER: 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13 (1)(a) 7., Florida Statutes: NAME, ADDRESS AND PHONE NUMBER: 8. In addition to himself or herself, Owner designates the following to receive a copy of the Lienor's Notice as provided in Section 713.13 (1)(b), Florida Statutes: NAME, ADDRESS AND PHONE NUMBER: 9. Expiration date of notice of commencement (the expiration date is 1 year from the date of recording unless a different date is specified) 20 . WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTTCF, OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713. PART I SECTION 713,13. FLOPMA STATUTES, AND CAN RFSULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPFJMON IF YOU INTEND TO OBTAIN FINANCING CONSULT WITH YOUR ••• M. —A e(ca- /' 1, 61- eC-n 6Wn r, P- Signature of Owner or Print Name and Provide Signatory's Tide/Office Owner's Authorized Officer/Director/Partner/Manager State of Florida County of St. Lucie, The foregoing instrument was acknowledged before me this - C) i ay of 2012— BY'—AIAl iUt.'�N as1A.Arr (Name of person) I (Type of authority... e.g. Owner, officer, trustee, attorney in fact) For r'rS:C (Name of party on behalf of whom instrument was executed) Personally Known—Zor prod Mli -01, LAURA M.SUTTERFIELD /Notary Public •State of Florida VYal if1• S1Jt ,Cld [fir o; My Commission Expires Oc! 24,2014 (Printed Name of Notary Public) \l (Signature o Notary PublldCommission A EE 24532 Under penalties of perjury, I declare that I have read the foregoing and that the facts in it are hue to the best of my knowledge and belief (section 92.525, Florida Statutes). Signature,((ss)J )er( of Owos) or Owner(s)' Authorized Officer/Director/Partner/Manager who signed above: ... By; ra— 11 . &2c4� By '•• plese sign iin both plates F LO R I DA STATE Q CT. LUCIEE COUNTY THI TRI 0R By Da Feb 09 12 08:57a • 0 p.1 Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue _ Fort Pierce, FL 34982 772-462-2165 or 772-462-2172 Fax: 772-462-6443 ROOF INSPECTION AFFIDAVIT Re: Permit # 12- U C'+G 5" I� Michael Miller , licensed as a(n)Contractor*/Engineer/Architect (Please print name & circle license type) *FS468 Building Inspector *General, Building, Residential or Roofing Contractor or any individual certified under 468 F.S. to make such an inspection. On or about `� ( i z I did personally inspect the roof deck nailing (Date) work at: 7705 James Rd Fort Pierce, FL 34951 (Job site address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S.) CC-CO57399 Signature and Seal License # STATE OF FLORIDA COUNTYOF St. Lucie Sworn`o an subscribed before me this day of - 20 A by�'YI� (`_ Eg_t�G 1?. . Who is personally known to me or who has produced as identification. Notary Public, State of Florid Signature of Notary: Commission Number: (Seal) En 01/19/2011 t rd. ° = AUdREY 6. HUMPHREY MY CONUISS10N O EE �S115A March 8, 2015 �oi�t4k EXPIRES: s ^c �'`o v 4 : '' 6onded7hru PJatery Fntillc Jnderv+tlte Florida Building Code Online Page 1 of 2 Business & Professional Regulation Florida DepartmPR-a BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats & Facts I Publications I FBC Staff I BCIS Site Map I Links I Search I Busines Prof ssilQr iProduct Approval USER: Public User Regulation Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL10674-R5 Application Type Revision Code Version 2007 Application Status Approved *Approved by DCA. Approvals by DCA shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Certification Agency Validated By Referenced Standard and.Year (of Standard) Equivalence of Product Standards Certified By Owens Coming One Owens Coming Parkway Toledo, OH 43659 (740)404-7829 greg.keeler@owenscorning.com Darrel Higgs darrel.higgs@owenscorning.com Darrel Higgs One Owens Corning Parkway Toledo, OH 43659 (419) 248-7060 darrel.higgs@owenscorning.com Roofing Asphalt Shingles Certification Mark or Listing Underwriters Laboratories Inc. Robert J. M. Nieminen, PE [] Validation Checklist - Hardcopy Received Standard Year ASTM D3161, Class F 2003 ASTM D3462 2004 ASTM D6381, Class H 2O03 ASTM D7158, Class H 2O05 TAS 107 1995 UL 2390, Class H 2O04 FILE COPY h4://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5 V %2b... 2/6/2012 Florida Building Code Online Page 2 of 2 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Method 1 Option A 07/20/2011 07/20/2011 07/25/2011 Summary of Products FL It IlModel, Number or Na IDescription 10674.1 Owens Corning Asphalt Roofing 3-tab, laminated, starter, and hip & ridge Shingles and Starters Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL10674 R5 C CAC AH] letter 2-21-11.pdf Approved for use outside HVHZ: Yes FL10674 R5 C CAC UL Certification Documents.pdf Quality Assurance Contract Expiration Date Impact Resistant: N/A Design Pressure: N/A 02/21/2012 Other: Refer to UL Certification uploads for fastening Installation Instructions requirements and substrate limitations. FL10674 R5 II BERKSHIRE SHINGLES.Ddf FL10674 R5 II DURATION SHINGLES.pdf FL10674 R5 II HIP RIDGE SHINGLES.pdf FL10674 R5 II OAKRIDGE SHINGLES.pdf FL10674 R5 II STARTERS.Ddf FL10674 R5 II THREE -TAB SHINGLES.pdf FL10674 R5 II WEATHERGUARD HP.Ddf Verified By: Underwriters Laboratories Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Back Next Contact Us :: Phone: 850-487-1824 1940 North Monroe Street, Tallahassee FL 32399 The State of Florida is an AA/EEO employer. Copyright 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, e-mail addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions regarding DBPR's ADA web accessibility, please contact our Web Master at webmaster(@dbor.state.Fl.us. Product Approval Accepts: ® ® fC9 M sclvritvm imi ics- YerlSlae n Wrisigd Vf 91FY� hnp://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgtBNbEY5V%2b... 2/6/2012 UUnderwriters � Laboratories Inc.o February 21, 2011 Mr. Ted Berman P.E. Senior Project Manager A&A Arnold & Associates, Inc. 1711 W 38th Place, Unit 1207 Hialeah, FL 33012-7077 Subject: Owens Corning Dear Mr. Mr. Berman: Northbrook Division 333 Pfingsten Road Northbrook, IL 60062-2096 USA www.ul.com tel:1 847 272 8800 fax: 1 847 272 8129 Customer service:1 877 854 3577 This is to confirm that, Oakridge® (continuous or dashed sealant) , Duration® and Duration® Premium (SureNail® strip with fabric or film) and (continuous or dashed sealant), Classic® AR, Supreme® AR, Berkshire® and WeatherGuard® HP shingles are Listed in accordance with ANSWUL790-04, Class A (ASTM E 108, Class A), ASTM D3462-04, ASTM D3161-03b Class F, ASTM D7158-05 and/or UL2390-041, ASTM D 6381-03 Class H and Dade County Protocol TAS 107-95. er re secure wtt nail s eat a uar secure wig Hari an a I of er s l �i - es seen a wit an s. Hip & Ridge with sealant, High Ridge, WeatherGuard HP and Berkshire Hip and Ridge shingles and Starter Strip Plus shingles are listed in accordance with ANSI/UL790-04, Class A (ASTM E 108, Class A), ASTM D3462-04, ASTM D3161-03b Class F, and Dade County Protocol TAS 107-95. ,i Dan -- s males secure . i ' ' nail s an, = �tr, � , ' wit M nails. Starter Shingle Roll is listed for use in the installation of ANSI/UL 790-04, Class A (ASTM E 108, Class A) shingles. All the products have been tested and meet the criteria for these standards and are covered by UL's Follow -Up Service Program for File R2453 and R19380 when applied in accordance with manufacturer's installation instructions. If you should have any questions, please feel free contact the writer. Very truly yours, Martin K. Rowan (Ext. 42349) Senior Project Engineer Fire Protection Division An Independent organization working for a safer world with integrity, precision and knowledge. FLORIDA PRODUCT APPROVAL FL10674-! ',REFER TO UL CERTIFICATION UPLOADS;, ',FASTENING REQUIREMENTS AND SUBSTRATE LIMITATIONS Application Instructions FTapajuntasesig.1 SpecialtyFlashing 7 espeeial para ateros Before installing this product, check local building codes for their roofing requirements. These shingles are designed for new or reroofing work over any properly built and supported wood roof deck having adequate nail holding capacity and a smooth surface. Check local building codes. Precautionary Note. The manufacturer will not be responsible for problems resulting from any deviation from the recommended application Instructions and the following precautions: Roof Top Loading: Lay shingle bundles flat Do not bend over the ridge. Roof Deck: • 6' Maximum roof deck boards • Minimum 3B' plywood - Minimum 7/16' OSB Regardless of deck type used, the roofing installer must: 1. Install the deck material in strict compliance with the deck manufacturer's Instructions. 2. Prevent the deck from getting wet before, during and after installation. Ventilation: Must meet or exceed FHA Minimum Property Standards. Handling: Use extra care in handling shingles when the temperature is below 40-F. Storage: Store in a covered ventilated area at a maximum temperature of 11WE Bundles should be stacked flat Protect shingles from weather when stored at the lob site. Do not store near steam pipes, radiators, etc. Fastener requirement: Use galvanized steel, stainless steel, or aluminum nails minimum 12 gauge shank with 318" diameter head. Owens Coming— recommends that fasteners comply with ASTM F 1667. Check local building codes. Progterly Driven improperly Driven sy gle 31Cmio. Ild' aeamg All Fasteners must penetrate at least 3/4' Into the wood deck or completely through sheathing. Notice: Owens Corning- recommends the use of nails as the preferred method of attaching shingles to wood decking or other naflable surface. 1. Specialty Eave Flashing: Where required by code. WeatherLocks underayment or equivalent eave and flashing membrane applied to a point at least 24" beyond interior wall line. See manufacturers installation instructions See Fig. 1. 2. Underlayment: Standard Slope 14' In 12' or morel Application of underlayment, metal drip edges, and eaves flashing: See Fig. 2. (A) Apply one layer of underlayment over metal drip edge at eaves. Use only enough fasteners to hold In place. (B) Overlap successive courses 2". Overlap course ends 4"_ Side laps are to be staggered 6' apart. (C) Apply metal drip edge over underlayment at rake. Favestiashing where mpilrod brcuda rapujimbspainakros don debrepdera el cddigo de consIruaam. a �t Irpdg ' dude& read bprodmta;or Naarma rmraderapred 3 Underlayment Low Slope Pendiente baja del revestimiento PRECAW proveng-i- Consultea q Undedayment Standard Slope ig. L Penconteestdndardelrevestimiento slops4'in 1r ormare rbMienl®de 4pdg. ada 12 pdg arms eadedeg�n mhad tave,maretaoeaG &+rise &Itnpaoo 3 A Underlayment Low Slope A Pendiente baja del revestimiento Slops 2' ®12" to lasslhm V in 12" ISlnpes2' In 12'tolessthan l"in 72' Pendrerlesda2ptdg.wdal2pufp.,h2sbwr 6,4pdg.oda l2fg. pPandedmde2pfgmdar2plg.hotamnmdRSpdg.eadal2ryrg IQ rIQ .lr_ yetitdse�s ovedg., . tg ! smda u ea r eroded _ - 19` _ ' pvrmn. 4 Standard Fastening Pattem Esquema de instaladdn estdndar 4110pattem E5W-201odchM r � 1•� - 1— u --I N ,r-►I 65B' ruts Erm Nara 66Ar sm �° Fiposieda&bbprpurg. rLans Fiposnzdn deb6/al 4 Mansard or Steep Slope Fastening Pattern EsquenaWastalickiianpendentespi6almdadisomaasardas o rtftttem £sgumamn6chm 6bq,osue 6Fn,enem 5q— EV..kgade 6agetedares Epnicada& 55181,01 Sryapdg t r r = A r _ Faa 1' SpotsotAsghalt Cement Wenapmros&.m.doedaroco ae r pNgada -� �� vremnetoeo Toplep 6•m¢aFadlap gomoeoddao brpgposnidn 5�ad, 6pdg�omr. s ➢etnt apd4 4ix Nail Fastening Pattern Hsquema de instalacion con seis clavos aNaOPanem Esquon a am 6davos Imo- ,r -►I I<- ,r -►I 55ME, romre mros 66i8•Fapomre 111 Eaprvaidnde58J8pdg Errasr mdes6BPr'g Shingle Application �ig. 5 lnstalacOn de tejas slaaorcoose ffikm1ddd RA.Eddp - i,rdmda rdm6lrC tramleaedge -� instrucciones de instalacion Antes de calocar este producto, ver8ique los c6digos locates do construccidn para cancer los requlsltos do so techo. Estes telas ban side disenadas para to construcd6n de techos nuevos o of anegla de techos exlstentes sabre platatomias de madera canectamente construldas y que pawed Una apaddad de sulecliln de clavos y una superticle Use. Consulle los c6digos de constmcci6a locales. Aviso importante. El fabdcante no se hera responsable par los problemas quo suilan coma corlsecuencla de no segult exactamente las Instmcclones de mstaladbn recomendadas y de los sigulantes avisos tmponantes: Carga sabre histechos,. Colaque los paquetes de telas de manera piano sabre el [echo. No Ins debee sabre la cumbrera. Platatanna del techo:-Tablas de la plataforma del techo da 6 puig. de maxima •"pidg. come mlumai de madera tdplay -7116 puig. come minimo para panefes de fibra orientada Cualquierd qua sea el tipo de super6de utiraada, el Instalador del [echo debe: 1. tastalar at material de to plataforma sigufarudo estridamente las Instrucciones del fabricame. 2. Evitar qua la plataforma se mole antes, durante y despuds de Is Instalad6a. Veatilactdm Delia cumplir o exceder las norms minimas para propledades, estabtecidas par el HIA Use: Tenga mucho cufdado at usar y colocar las talas cuando la temperetura sea inferior a los 40eF. Almacenamlento: Almacene an on area cublerta y ventilada a one temperatora qua no sobrepase his 1101F143`C. Almacenar en forma plaaa. Proteja las lelas del c6ma cuando las almacene an of lugardetrdbale. No las almacene cerca de tuberfas da vapor, radfadmes, etc Requisite do suletador, Use claws do acem galvanUado, acem Inoxidable o de alaminio, do calibre 12 come mfaboo, con tin dametm de cabera de 18 puig. Owens Coming- recomfenda quo Ins suletadores cumplan con la norma ASTM F 1667. Cousuhe las cddigos de construodda locales. Btencolocado Malcolocado eEA,mehomfa - 1Rpa13. i i 3/•pdg. T clap llrpdg Emeblam to Todos his suldadores deben penetrdrat menus 314 puig. en la plataferma del techo M madera o atravesar completamente los revestimientris de madera triplay. Avlsm Owens ComingTM recomlenda el use de clavos come mdtode prefetldo para f7artelas a superpcfes de madera u otras supedicles allies para cloves. 1. Tapajuntas especial para elems: Donde to requiera at vidlpo. Revestimlento WeathelLockO, o Impermeabi tzame equivalente para alems ytapaluntas lastalada pasta on punto de at menus 24 pulp. pasando la Ifnea de to pared Interior. Consuh0las Instroalones do Instalachlo del fabdame. Ver la Fig. 1. 2.Revesttmlento: Pendiente esMader (4 puig. ada 12 pulgadas o mas) Insfalacidn del revestimiento, bordes de goteo metaiices y tpaluntas de alems: Ver to Fig. 2. (A) Instale one seccidn del revestimiento sabre el goteron meMlico del alem. UbOce la antldad estridamente nececada de suletadores para mardemula an so lugar. 161 Sobreponga las hderas sigulentes 2 pulgadas. Sobreponga [as extremes de las hileras 4 pulgadas. Las emoalmes laterales deben esalonarse a 6 pies de f� i FLORIDA PRODUCT APPROVAL FL10674—R5; REFER TO UL CERTIFICATION UPLOADS FOR FASTENING REQUIREMENTS AND SUBSTRATE LIMITATIONS 3. Undedayment: Low Slope (2" In 12" to less than 4" in 12") Application of underlayment, metal drip edges, and eaves flashing: See Fig. 3. (A) Apply 19" starter strip of underlayment over metal drip edge at eaves. Use only enough fasteners to hold it in place. (B) Use 36" strip of underlayment for remaining courses, overlapping each course 19". Side laps are to be staggered 6' apart. (Cl Apply metal drip edge over underlayment at rake. Or WeatherLock® self -adhered underlayment or equivalent with a standard over lap of 3 inches and metal drip edge. See Fig. 3A. 4. Shingle Fastening: Place fasteners 61/8" from bottom edge of each shingle and 1" from each end. Standard Pattern Use four fasteners. See Fig. 4 Six Nail Pattern Use six fasteners. See Fig. 4A Mansard or Steep Slope Fastening Pattern. Place fasteners 6118" from bottom edge to secure both layers of the shingle. See Fig. 48. Shingto Sift Vern REQUIRED: For slopes exceeding 60 degrees or 21 inches per foot, use six fasteners and four spots of asphalt roof cement per shingle. Apply immediately, one 1" diameter spot of asphalt roof cement under each shingle tab. Center asphalt roof cement 2" up from bottom edge of shingle tab. See Fig. 4B. Roof Cement where required must meet ASTM D-4586 Type I or 11(Asbestos Free). Six nail fastening pattern is required for Maximum wind warranty. In addition, Owens Coming— Starter Shingles are required along the save and rake. (See Starter Shingle instructions for details.) 5. Shingle Application: These shingles are applied with a 61W offset, with 5 518' exposure, over prepared roof deck, starting atthe bottom of the roof and working across and up. This will blend shingles from one bundle into the next and minimize any normal shade variation. Application with offsets of 4' or 8' are also acceptable. Caution must be exercised to assure that end joints are no closer than 2' from fastener in the shingle below and that side laps are no less than 4' in succeeding courses. Refer to course application steps for specific instructions. Starter Course: Use an Owens Coming— Starter product or trim 5 518' from the starter course shingle. Trim 6 112" off the rake of the starter course shingle and flush with the drip edge along the rake and eaves edge, and continue across the roof. Use 5 fasteners for each shingle, placed 2" to 3" up from eaves edge. See Fig. 5. (If no drip edge is used, shingles must extend a minimum of 1/2" and no more than 1" from rake and eaves edge.) First Course: Apply first course starting with the full shingle even with the starter course. See Fig. 5A. Fasten securely according to fastening Instructions. See Fig. 4. CIM� A A Shingle Application Fig. instalacidn de tejas C Shingle Application :ig. 5c lnstalacidn de tejas ll&d Course Tamara MOM �s naterda. —. m�c�`ffidn81`�a tal`0' to i.✓ra knedge Carta npdg, del6oNenWv a . Fig.Car ShingleApplication 7E lnstalacidn as tejas distancia. ICI Instate el borde de gateo de metal sabre el G Shingle Application 1g. J instalacibn de tejas revestimientoenlacomisa. 3. Revestimiento: Second Comse Pendlente baja (2 pulg. rada 12 pulg., a means de 4 sEYmfdafdkra pulg. Carla 12 Palo.) a ga61Pm0 Instaladdn del revestimlento, bordes de goteo rvp . met5licos y tapajuntas de alems: Ver la Fig. 2. n (AI Insists Una secclda initial de 19 pulgadas de 55y revestimlerdo sabre el goterdn metaffco del alero. Utilice la cantidad estrictamerde necesaria de e.I.tdge , V43 ti* sujetarlores pars manteneda ensu lugar. � 101 Use una secci6n de revestimiento de 36 pulgadas Para el resto de las h8eras, sobreponiendo ada tillers 19 pulgadas. Los empalmes laterales dehen Trio s rrr rmmr.h >s escalonarse a 6 pies do distancia. `ass Ca ev?pdg.dd =• ri�a nouda551apotg. " IC) Instate of bards de goteo do metal sabre at revesdmiento en Is camisa. Fig. �D Shingle Application lnsfalaradn de tejas Fig. SF ShingleApplication /nsfalacidn de tejas 6 Closed -Cut Valley Construction Construccidn del valle con torte con -ado O membrana autoadherente WeatherLock® o equivalents con una superposici6n estdndar de 3 pulgadas y borde de escummiento. Ver Is Fig.3A. 4.Sujeddn de las telas: Coloque los sujetadores a 6113 pulg. a partir del borde inferior do ada tela y a i pulg. de cada extremo. Esquema estdndar. Ublice cuatm suletadares. Ver la Fig. 4. Fsquema con seh davos Para 6 sujetadores. Ver to H9.4A. Esquema de Insbbcidn en pendlentes pronandadas o mansardas Coloque los sujetadores a 61111 pulgadas del horde Warier Para ajustarambas spas de la tela. Ver Is Fig.41L Vua mwar M ra Mra REQUIS90: Para pendientes de mas de 60 grados o 21 pulg. par pie, utflice sets sujetadores y aatro canbdades pe(juedas de cememo asfaitado par teja. Instate inmediatamente una secci6n con 1 pulg. de diftmetm decemento asfahado debajo de ada Ienglieta de las telas. Asegdrese de que el cemerdo asfaltado estd centrado 2 pulg. par endno del bards inferior de Is lengileta de la tela. Cuando sea necesado utilizar cements pamtechos, Este debe cumplkcan to norms ASTM D-4586Tips I611ism asbestos). M esquema delijul6n de sets davos es obligatodo parr Isgarantrarnaftacontra vientos.Ademas esnecesado Instatar las Islas Para la hilem initial de Owens Coming" en las comisas detrmpano ylos alem5. (Consults las Instmcciones de las telas para la hRera InIcIA pars obtener Wormad6n detallada). 5. lnstalacidn de las telas: Estas telas se instalan con un desplazamlento de 5 W pulg., can una supediide expuesta de5518 puig, sabre platafamias de techas preparada& to coloadOn comienza par to parts inferiordel techo yse reariza en forma transversal hada aniba. Be esta manes, las telas de an paquete se madan con las del siguiente y se reducen at minimo lasvadadones normales do tonal(dad. TarnUn se pueden instalar telas can on desplazamiento de 4 6 8 pulgadas, Asegdrese de que las unlones de Ins extremas nose encueitren a menos de 2 pulgadas del sujetador dela tela que se encaenta mas abalo, y que las superposidones laterales no sean de menasdo 4 pulgadas en las luleras sigulentes. Cansulte los pasos de Instalaci6a de hileras pars ver las insuucciones especifias. HBem inlciat Ublice un rollo de inicio o carte 5 516 pulg. de to tela de fa h0em inicial. Corte 6112 pulg. desde Is viga incknada en Is tela de la hilera initial yextienda. mas alla de Isviga inclinada yel horde del alem, y rnMinde a to ancho del techo. Utflice 5 sujetadares pare ada tela, coloados a FLORIDA PRODUCT APPROVAL FL10674 r 1 REFER TO UL CERTIFICATION UPLOADS,' -3 FASTENING REQUIREMENTS AND r SUBSTRATE LIMITATIONS Second Course: Remove 6112" from the left end of this shingle and apply the remaining piece over 1 Step Flashing and above the first course shingle and flush Fig 1 Tapajuntas escalonado with edge of the first course with 5 518' exposure. See Fig. 59. IaeW Bashing Fasten securely according to fastening av d instructions. See Fig. 4. T� fmsd;ni Third Course: mp.d°r°ng3dxspmlg.m°sd�fir u�aa°xmrow Remove 13' from the left end of this WPr°�0S 0D shingle and apply the remaining piece over FVAupedind , and above the second course shingle flush°r with edge of the second course with 5 518' rvoads,.ip°ry exposure. See Fig. 5C- ' Fasten securely according to fastening -- instructions. See Fig. 4. Fourth Course: / I Remove 19 112' from the left end of this ' /" shingle and apply the remaining piece over and above the third course shingle and flush with edge of the third course with 5 518' exposure. See Fig. 5D. Fasten securely according to fastening Instructions. See Fig. 4. Fifth Course: Remove 26' from the left end of this shingle and apply the remaining piece over and above the fourth course shingle and flush with edge of the fourth course with 5 518' exposure. See Fig. 5E. Fasten securely according to fastening Instructions- See Fig. 4. Sixth Course: Remove 3211T from the left end of this shingle and apply the remaining piece over and above the fifth course shingle and flush with edge of the fifth course with 5 518' exposure. See Fig. 5F. Fasten securely according to fastening instructions. See Fig. 4. Succeeding Courses: For succeeding courses, repeat first through sixth course- See Fig. 5G- G. Valley Construction: Closed -Cut Valley See Fig. 6. A closed -cut valley can be used as an alternative to woven and open valley and is applied as follows: Lay, a 36' wide valley liner of self adhered membrane underlayment or equivalent. A 36' wide minimum 50 Ib- smooth surface roll roofing can also be used as a valley liner. Lay all shingles on one side of valley and across center line of valley a minimum of 12'. Fasten a minimum of 6' away from center line on each side of valley. Strike a chalk line 2' from the center line of the unshingled side. Apply shingles on the unshingled side up to the chalk line and trim, taking care not to cut the underlying shingles. Clip upper comers of these shingles, cement and fasten. Roth woven and metal valleys are acceptable alternatives. 7. Step Flashing: Use 10" long and 2" wider than expected exposure corrosion -resistant metal where roof planes butt against vertical sidewalls or chimneys. See Fig.7. 8- Hip & Ridge Application: Use corresponding Owens Coming— hip & ridge shingles to best complement shingle color. Follow specific application instructions as printed on the hip & ridge shingle package. SeeFig. 8- 8 Hip & Ridge Application Hip, de cabailetes yaunbreias na° "w®duierm EV— Dic iuodAee,P°prtdm,ue°f° EV­ 4� una distanda de entire 2 y 3 pulgadasdel borde del alero. Ver Is Rg. 5. IS] no uIlliza on horde its poteo. List" deben extenderse, on minlmo de 112 pulgada y on m9xlmo de 1 pulgada de Is viga Indinada y at borde del alarol. Pdmerahilem Coloque Is primers Went comenrando con Is Isla enters alineada con Is hilera laical. Ver Is Rg. W Sujete firmemente de acuerdo con las instmcciones de suWidn. Ver Is Rg. 4. Segundah0em Quite 612 pulg. del borde izquierdo its esta Isis y aprique Is plaza restante sabre y porendma its Is feja de Is primers fillers y all ras del borde de la primers hfeM con 5 5t8 puig, de exposicidn. Ver Is Fig. 5B. Sujete firtnemerde de acuerdo can las inshuccfones de sujecida. Ver Is Rg. 4. Tercera hUara: Quite 13 palg. del horde izgaierdo de esta taja yaprique la plaza restante sabrey par encima de Is teja de le segunda hilem y al ras del borde de la segunda hfera, can 5 518 pulg. de exposiddn. Ver Is Fig. 5C. Sujete firmamente de acuerdo can las Insirucciones de sujecido. Ver Is Fig. 4. aria Mora: uite 1912 ping. del horde izquierdo deesta teja y aprique is plaza restante sabre y par errdma de Is teja its U temem fillers V at s dell borde its la terraria hilera, con 5 5r8 pulg. de exposicidn. Ver Is Fig.50. Sujete firmemente de acuerdo con las inAmcciones sujedim. Ver Is Fig. 4. uluta Meur uite26 puig. del borde tzquierdo de, esta teia y aplique la plaza restante sobrey porencuna de Is teja de Is cuada Nora Val ras del Ne de to cuarta lulera, can 5 511 ping. de exposicidn. Ver la Rg. 5E Sujete fnimemente de acuerdo con las lnstruccones its s ijecl6n.Verla Rg. 4. a h8era: Wile 3212 puig. del borde tzgoierdo de estateja yapiique Is plaza restante sabre V par encima de la tela de Is quints idlers Val ras I borde de la quints biters, can 5 518 pulg. de exposiddn. Ver Is Fig. 5F. Sujete famemerde de acuerdo con las insbucclanes de s ijecidn. Ver la Fig. 4. eras sigulerdes no In hfleras sigutentes, repita Ins pasos qua se inddcan desde Is primers basis Is sexta Were. Ver la Fig. SG. LConstmcd6n deivafe: e ceaado VerFjg.6. Un valle con code cerrado posits ser usado coma ahemafiva a on valle tejido o abiertoy se colors de to sigularde manes Cotoquean el valle on impermeabilizante autoadhesivo a equivalents con 26pulgadas de ancho. Para revestir el valie,tambien se puede Ldiftaron rollo de techado its 36 pulg. de ancho y on minimo de 50libras. Coloque todas las tejas sabre on )ado dal va0e y a trai de Is Ilnea central del va0e al mans 12 putgadas. Sujete a on minimo de 6 putgadas de to Unea central a rada lado del valle. Marque Una lines de tiza a 2 putgadas de to lines central del lado qua nofeneteias. Coloque las tejas del lado qua no tiene Islas basis Is Unea de fza V reoute, con cuidada its no cortar [astejas quo se encuerban debajo. Una Ins extremos superiores de estastei coloque cemento y Sujete Se pueden uill®rvalles detejidoo metal. 7 Tapajonlasestalonado: ice metal rssisiente a la ourrosidn con Una exposicidn its 10 putgadas de longitud y do 2 putgadas mds de andio qua to osictdn esperada an ins pumas an los qua las pianos del techo se iman a las parades laterates vadicales o a chimeneas-Ver Is 9.7- ApUeaddn pars caballete v cumbrers M ce tejas pars cabaltetes y cumbrerds. Stga las instrucdones de instalacidn del paquete de caballetes V cumbrems. Ver Is Fig. R