HomeMy WebLinkAboutSUBMITTED PAPERSDATE: OL . FEES _j IJ O �-J RECEIPT #: t Permit #: `
4:: :: emu. Planning & Development Services Department
UVTYBuilding & Code Regulation Division n
c 2300 Virginia Avenue 6s�iN " rD
Ft. Pierce, FL 34982-5652 13
Tel.772462-1553 St. Lucia county
APPLICATION FOR ROOF PERMIT_
SEE REVERSE SIDE FOR INSTRUCTIONS
1. Location/Site Address: 7705 James Rd..
2. Parcel ID Number: 1301-603-0018-000-7.
Office Use
Only
Section
Townshi
Range
Ma Page
ZoningLand
Use
Initials
3. Description of Project or Work Activity: Remove existing shingles, Dry in, Install new OC Pro 30 Shingles.
4. Total Roof Area (square feet): 2200• 5. Roof Pitch: 3/12.
6. Type of Roof:
[¢ ] Fiberglass Shingle
[ 1 ] Tar & Gravel
[ ] Concrete Roof Tile [ ] Wood Shake / Shingle
[ ] Modified Bitumen [ ] Other
[ ] Product Approval required for all types of Roofing Material (2 Sets)
[ ] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product
Approval attached
** Roof Mitigation per F.S. 553.844 will be required.
7. Owner Information 8. Contractor Information
Name: Reba Bryan .
Address: 7705 James Rd.
City: Fort Pierce.
Zip: 34951.
State: FL.
Phone: 465-0270.
9. Value of Construction: $ 6,690.
FL Reg/Cert #: CC-0057399
County Cert #:
16414
Business Name: Trade Winds Roofing Inc
Cell Phone: 772-466-9420
"Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval.
CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be
done in compliancre�w�applicable lating construction and zoning.
Michael Miller _ "�' V
PRINT QUALIFIERS/OWNERS NAME SI NATURE OF QUALIFIER/OWNER
STATE OF FLORIDA, COUNTY OF
ACKNOWLEDGED BEFORE ME THIS W DAY OF 20, BY ; der
IS PERSONA LL OWN TO ME OR HAS PRODUCED AS IDENTIFICATION
�. . 014 "l may
A OROTARY Tim,OR PRINT NAME OF NO ARY (seal)
COMMISSION NUMBER
NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE
FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
Revised 4/26/2010 _
AUDREY 8. HUMPHREY
* MY COMMISSION # EE 061159
EXPIRES: March 6, 2015
Bonded Thru Notary Public Underwriters
J `�
INSTRUCTIONS
Please complete all information in the space provided. All information must be printed (use black or blue ink
only) or typed. This roof permit application is to be used only for those activities that are not otherwise included
under a primary building permit. This application may not be used for any activity that includes structural
alteration. Building activities involving structural alteration, in addition to the roof work, must be permitted
through the regular building permit review process. The information to be provided with this application
includes:
1. Location/Site Address
2. Parcel ID Number
3. Description of Project or Work Activity
4. Total Roof Area
5. Type of Roof
6. Owner Information
7. Contractor Information
8. Value of Construction
Indicate the street address or general location of the
property where the building activity is taking place.
Indicate the tax identification number of the property where
the building activity is taking place.
Completely describe the building activity to take place.
Please indicate if tear -off or shingle over shingle etc.
Indicate total roof area to be affected by this permit. Also
indicate the pitch of the roof, expressed as a standard ratio
of run rise.
Indicate the type of roof being repaired or resurfaced.
Indicate the name and address of the owner of the property
on which building activity is taking place.
Indicate the State of Florida registration number (if
applicable), St. Lucie County contractor license number and
the name of the business doing the work.
Indicate the total value of the work to take place. Total cost
of construction includes all material and labor costs
associated with the building/construction activity.
Construction value is used to detennine the permit fee. St.
Lucie County reserves the right to question and/or modify
the indicated value of construction if it is demonstrated that
the submitted figures are not consistent with similar types
of construction.
This application can be submitted to St. Lucie County Building and Zoning, 2300 Virginia Avenue, Fort Pierce,
FL 34982. All permit applications must be filled out completely before submission. No applications will be
accepted for processing after 4:30 P.M. For assistance in completing this application, please call (772)
462-1553, during regular office hours (8:00 AM - 5:00 PM), Monday through Friday.
Upon issuance of this permit, required inspections can be scheduled by calling (772) 462-1261.
St. Lucie County Roof Permit Application rev. 3/1/2009
JOSEPH E. SMITH, CLERK OF THE CIRCUIT COURT — SAINT LUCIE COUNTY
FILE # 3671468 OR BG�--e,,3360 PAGE 1641, Recorded 02/06/201,Kl12:51 PM
y i
PERMIT NUMBER:
NOTICE OF COMMENCEMENT
The undersigned hereby given notice that improvement will be made to certain real property, and in accordance with Chapter 713,
Florida statutes the following information is provided in the Notice of commencement.
1. DESCRIPTION OF PROPER al description and street address) TAX FOLIO NUMBER: 1301-603-0018-000-7
SUBDIVISION I akewood � 17 TRACT 18 BLDG UNIT
7705 James Rd, Fort Pierce, FL 34951
2. GENERAL DESCRIPTION OF IMPROVEMENT. reroof
3.OWNER INFORMATION: a. Name Reba M Bryan
b. Address 7705 James Rd., Fort Pierce, FL 34951 c. interest in property
d. Name and address of fee simple titleholder (if other than owner)
4. CONTRACTOR'S NAME, ADDRESS AND PHONE NUMBER: Trade Winds Roofing, Inc.
P.O. Box 13208, Fort Pierce, FL 3,4979 772-466-9420
5. SURETY'S NAME, ADDRESS AND PHONE NUMBER AND BOND AMOUNT:
6. LENDER'S NAME, ADDRESS AND PHONE NUMBER:
7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by
Section 713.13 (1)(a) 7., Florida Statutes:
NAME, ADDRESS AND PHONE NUMBER:
8. In addition to himself or herself, Owner designates the following to receive a copy of the Lienor's Notice as provided in Section
713.13 (1)(b), Florida Statutes:
NAME, ADDRESS AND PHONE NUMBER:
9. Expiration date of notice of commencement (the expiration date is 1 year from the date of recording unless a different date is
specified) 20 .
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTTCF, OF COMMENCEMENT
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713. PART I SECTION 713,13. FLOPMA STATUTES, AND CAN RFSULT
IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND
POSTED ON THE JOB SITE BEFORE THE FIRST INSPFJMON IF YOU INTEND TO OBTAIN FINANCING CONSULT WITH YOUR
••• M. —A e(ca- /' 1, 61- eC-n 6Wn r, P-
Signature of Owner or Print Name and Provide Signatory's Tide/Office
Owner's Authorized Officer/Director/Partner/Manager
State of Florida
County of St. Lucie,
The foregoing instrument was acknowledged before me this - C) i ay of 2012—
BY'—AIAl iUt.'�N as1A.Arr
(Name of person) I (Type of authority... e.g. Owner, officer, trustee, attorney in fact)
For r'rS:C
(Name of party on behalf of whom instrument was executed) Personally Known—Zor prod
Mli
-01, LAURA M.SUTTERFIELD
/Notary Public •State of Florida
VYal if1• S1Jt ,Cld [fir o; My Commission Expires Oc! 24,2014
(Printed Name of Notary Public) \l (Signature o Notary PublldCommission A EE 24532
Under penalties of perjury, I declare that I have read the foregoing and that the facts in it are hue to the best of my knowledge and
belief (section 92.525, Florida Statutes).
Signature,((ss)J
)er( of Owos) or Owner(s)' Authorized Officer/Director/Partner/Manager who signed above:
... By; ra— 11 . &2c4� By
'•• plese sign iin both plates F LO R I DA
STATE Q
CT. LUCIEE COUNTY
THI
TRI
0R
By
Da
Feb 09 12 08:57a
•
0
p.1
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
_ Fort Pierce, FL 34982
772-462-2165 or 772-462-2172
Fax: 772-462-6443
ROOF INSPECTION AFFIDAVIT
Re: Permit # 12- U C'+G 5"
I� Michael Miller , licensed as a(n)Contractor*/Engineer/Architect
(Please print name & circle license type) *FS468 Building Inspector
*General, Building, Residential or Roofing Contractor or any individual certified under 468 F.S. to make such an inspection.
On or about `� ( i z I did personally inspect the roof deck nailing
(Date)
work at: 7705 James Rd Fort Pierce, FL 34951
(Job site address)
Based upon that examination I have determined the installation was done according to the Hurricane
Mitigation Retrofit Manual (Based on 553.844 F.S.)
CC-CO57399
Signature and Seal License #
STATE OF FLORIDA
COUNTYOF St. Lucie
Sworn`o an subscribed before me this day of - 20 A
by�'YI� (`_ Eg_t�G 1?. . Who is personally known to me or who has produced
as identification.
Notary Public, State of Florid
Signature of Notary:
Commission Number: (Seal)
En 01/19/2011
t rd.
° =
AUdREY 6. HUMPHREY
MY CONUISS10N O EE �S115A
March 8, 2015
�oi�t4k
EXPIRES: s
^c �'`o v
4 : ''
6onded7hru PJatery Fntillc Jnderv+tlte
Florida Building Code Online Page 1 of 2
Business & Professional Regulation
Florida DepartmPR-a
BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats & Facts I Publications I FBC Staff I BCIS Site Map I Links I Search I
Busines
Prof ssilQr iProduct Approval
USER: Public User
Regulation
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
FL10674-R5
Application Type
Revision
Code Version
2007
Application Status
Approved
*Approved by DCA. Approvals by DCA shall be reviewed and
ratified by the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Certification Agency
Validated By
Referenced Standard and.Year (of Standard)
Equivalence of Product Standards
Certified By
Owens Coming
One Owens Coming Parkway
Toledo, OH 43659
(740)404-7829
greg.keeler@owenscorning.com
Darrel Higgs
darrel.higgs@owenscorning.com
Darrel Higgs
One Owens Corning Parkway
Toledo, OH 43659
(419) 248-7060
darrel.higgs@owenscorning.com
Roofing
Asphalt Shingles
Certification Mark or Listing
Underwriters Laboratories Inc.
Robert J. M. Nieminen, PE
[] Validation Checklist - Hardcopy Received
Standard
Year
ASTM D3161, Class F
2003
ASTM D3462
2004
ASTM D6381, Class H
2O03
ASTM D7158, Class H
2O05
TAS 107
1995
UL 2390, Class H
2O04
FILE COPY
h4://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5 V %2b... 2/6/2012
Florida Building Code Online Page 2 of 2
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Method 1 Option A
07/20/2011
07/20/2011
07/25/2011
Summary of Products
FL It
IlModel, Number or Na
IDescription
10674.1
Owens Corning Asphalt Roofing
3-tab, laminated, starter, and hip & ridge
Shingles and Starters
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: No
FL10674 R5 C CAC AH] letter 2-21-11.pdf
Approved for use outside HVHZ: Yes
FL10674 R5 C CAC UL Certification Documents.pdf
Quality Assurance Contract Expiration Date
Impact Resistant: N/A
Design Pressure: N/A
02/21/2012
Other: Refer to UL Certification uploads for fastening
Installation Instructions
requirements and substrate limitations.
FL10674 R5 II BERKSHIRE SHINGLES.Ddf
FL10674 R5 II DURATION SHINGLES.pdf
FL10674 R5 II HIP RIDGE SHINGLES.pdf
FL10674 R5 II OAKRIDGE SHINGLES.pdf
FL10674 R5 II STARTERS.Ddf
FL10674 R5 II THREE -TAB SHINGLES.pdf
FL10674 R5 II WEATHERGUARD HP.Ddf
Verified By: Underwriters Laboratories Inc.
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
Back Next
Contact Us :: Phone: 850-487-1824 1940 North Monroe Street, Tallahassee FL 32399
The State of Florida is an AA/EEO employer. Copyright 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, e-mail addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not
send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions regarding DBPR's ADA web
accessibility, please contact our Web Master at webmaster(@dbor.state.Fl.us.
Product Approval Accepts:
® ® fC9 M
sclvritvm imi ics-
YerlSlae n
Wrisigd
Vf 91FY�
hnp://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgtBNbEY5V%2b... 2/6/2012
UUnderwriters
� Laboratories Inc.o
February 21, 2011
Mr. Ted Berman P.E.
Senior Project Manager
A&A Arnold & Associates, Inc.
1711 W 38th Place, Unit 1207
Hialeah, FL 33012-7077
Subject: Owens Corning
Dear Mr. Mr. Berman:
Northbrook Division
333 Pfingsten Road
Northbrook, IL 60062-2096 USA
www.ul.com
tel:1 847 272 8800
fax: 1 847 272 8129
Customer service:1 877 854 3577
This is to confirm that, Oakridge® (continuous or dashed sealant) , Duration® and Duration®
Premium (SureNail® strip with fabric or film) and (continuous or dashed sealant), Classic® AR,
Supreme® AR, Berkshire® and WeatherGuard® HP shingles are Listed in accordance with
ANSWUL790-04, Class A (ASTM E 108, Class A), ASTM D3462-04, ASTM D3161-03b Class
F, ASTM D7158-05 and/or UL2390-041, ASTM D 6381-03 Class H and Dade County Protocol
TAS 107-95. er re secure wtt nail s eat a uar secure wig Hari an a I of er
s l �i - es seen a wit an s.
Hip & Ridge with sealant, High Ridge, WeatherGuard HP and Berkshire Hip and Ridge shingles
and Starter Strip Plus shingles are listed in accordance with ANSI/UL790-04, Class A (ASTM E
108, Class A), ASTM D3462-04, ASTM D3161-03b Class F, and Dade County Protocol TAS
107-95. ,i Dan -- s males secure . i ' ' nail s an, = �tr, � , ' wit M nails.
Starter Shingle Roll is listed for use in the installation of ANSI/UL 790-04, Class A (ASTM E
108, Class A) shingles.
All the products have been tested and meet the criteria for these standards and are covered by UL's
Follow -Up Service Program for File R2453 and R19380 when applied in accordance with manufacturer's
installation instructions.
If you should have any questions, please feel free contact the writer.
Very truly yours,
Martin K. Rowan (Ext. 42349)
Senior Project Engineer
Fire Protection Division
An Independent organization working for a safer world with integrity, precision and knowledge.
FLORIDA PRODUCT APPROVAL FL10674-! ',REFER TO UL CERTIFICATION UPLOADS;, ',FASTENING REQUIREMENTS AND
SUBSTRATE LIMITATIONS
Application Instructions FTapajuntasesig.1 SpecialtyFlashing
7 espeeial para ateros
Before installing this product, check local
building codes for their roofing
requirements.
These shingles are designed for new or
reroofing work over any properly built and
supported wood roof deck having adequate
nail holding capacity and a smooth surface.
Check local building codes.
Precautionary Note.
The manufacturer will not be responsible
for problems resulting from any deviation
from the recommended application
Instructions and the following precautions:
Roof Top Loading: Lay shingle bundles flat
Do not bend over the ridge.
Roof Deck: • 6' Maximum roof deck boards
• Minimum 3B' plywood - Minimum 7/16' OSB
Regardless of deck type used, the roofing
installer must:
1. Install the deck material in strict
compliance with the deck manufacturer's
Instructions.
2. Prevent the deck from getting wet before,
during and after installation.
Ventilation: Must meet or exceed FHA
Minimum Property Standards.
Handling: Use extra care in handling
shingles when the temperature is below 40-F.
Storage: Store in a covered ventilated area
at a maximum temperature of 11WE
Bundles should be stacked flat Protect
shingles from weather when stored at the
lob site. Do not store near steam pipes,
radiators, etc.
Fastener requirement: Use galvanized steel,
stainless steel, or aluminum nails minimum
12 gauge shank with 318" diameter head.
Owens Coming— recommends that fasteners
comply with ASTM F 1667. Check local
building codes.
Progterly Driven improperly Driven
sy gle
31Cmio. Ild' aeamg
All Fasteners must penetrate at least
3/4' Into the wood deck or completely
through sheathing.
Notice: Owens Corning- recommends the
use of nails as the preferred method of
attaching shingles to wood decking or
other naflable surface.
1. Specialty Eave Flashing:
Where required by code.
WeatherLocks underayment or equivalent
eave and flashing membrane applied to a
point at least 24" beyond interior wall line.
See manufacturers installation instructions
See Fig. 1.
2. Underlayment:
Standard Slope 14' In 12' or morel
Application of underlayment, metal drip
edges, and eaves flashing: See Fig. 2.
(A) Apply one layer of underlayment over
metal drip edge at eaves. Use only enough
fasteners to hold In place.
(B) Overlap successive courses 2". Overlap
course ends 4"_ Side laps are to be
staggered 6' apart.
(C) Apply metal drip edge over
underlayment at rake.
Favestiashing where mpilrod brcuda
rapujimbspainakros don debrepdera
el cddigo de consIruaam.
a
�t
Irpdg ' dude&
read bprodmta;or
Naarma
rmraderapred
3 Underlayment Low Slope
Pendiente baja del revestimiento
PRECAW
proveng-i-
Consultea
q Undedayment Standard Slope
ig. L Penconteestdndardelrevestimiento
slops4'in 1r ormare
rbMienl®de 4pdg. ada 12 pdg arms
eadedeg�n
mhad
tave,maretaoeaG
&+rise &Itnpaoo
3 A Underlayment Low Slope
A Pendiente baja del revestimiento
Slops 2' ®12" to lasslhm V in 12" ISlnpes2' In 12'tolessthan l"in 72'
Pendrerlesda2ptdg.wdal2pufp.,h2sbwr 6,4pdg.oda l2fg. pPandedmde2pfgmdar2plg.hotamnmdRSpdg.eadal2ryrg
IQ rIQ .lr_ yetitdse�s
ovedg., . tg ! smda u ea r
eroded _ - 19` _ ' pvrmn.
4 Standard Fastening Pattem
Esquema de instaladdn estdndar
4110pattem
E5W-201odchM
r � 1•�
-
1— u --I
N ,r-►I
65B' ruts
Erm Nara
66Ar sm
�°
Fiposieda&bbprpurg. rLans
Fiposnzdn deb6/al
4 Mansard or Steep Slope Fastening Pattern
EsquenaWastalickiianpendentespi6almdadisomaasardas
o rtftttem
£sgumamn6chm
6bq,osue 6Fn,enem 5q—
EV..kgade 6agetedares Epnicada&
55181,01 Sryapdg
t r r
= A
r _
Faa 1' SpotsotAsghalt Cement
Wenapmros&.m.doedaroco ae r pNgada
-� �� vremnetoeo
Toplep 6•m¢aFadlap gomoeoddao
brpgposnidn 5�ad, 6pdg�omr.
s ➢etnt apd4
4ix Nail Fastening Pattern
Hsquema de instalacion con seis clavos
aNaOPanem
Esquon a am 6davos
Imo- ,r -►I I<- ,r -►I
55ME, romre mros 66i8•Fapomre 111
Eaprvaidnde58J8pdg Errasr mdes6BPr'g
Shingle Application
�ig. 5 lnstalacOn de tejas
slaaorcoose
ffikm1ddd
RA.Eddp -
i,rdmda
rdm6lrC
tramleaedge -�
instrucciones de instalacion
Antes de calocar este producto, ver8ique los c6digos
locates do construccidn para cancer los requlsltos do
so techo.
Estes telas ban side disenadas para to construcd6n de
techos nuevos o of anegla de techos exlstentes sabre
platatomias de madera canectamente construldas y
que pawed Una apaddad de sulecliln de clavos y una
superticle Use.
Consulle los c6digos de constmcci6a locales.
Aviso importante.
El fabdcante no se hera responsable par los problemas
quo suilan coma corlsecuencla de no segult
exactamente las Instmcclones de mstaladbn
recomendadas y de los sigulantes avisos tmponantes:
Carga sabre histechos,. Colaque los paquetes de telas
de manera piano sabre el [echo.
No Ins debee sabre la cumbrera.
Platatanna del techo:-Tablas de la plataforma del
techo da 6 puig. de maxima •"pidg. come mlumai de
madera tdplay -7116 puig. come minimo para panefes
de fibra orientada
Cualquierd qua sea el tipo de super6de utiraada, el
Instalador del [echo debe:
1. tastalar at material de to plataforma sigufarudo
estridamente las Instrucciones del fabricame.
2. Evitar qua la plataforma se mole antes, durante y
despuds de Is Instalad6a.
Veatilactdm Delia cumplir o exceder las norms
minimas para propledades, estabtecidas par el HIA
Use: Tenga mucho cufdado at usar y colocar las talas
cuando la temperetura sea inferior a los 40eF.
Almacenamlento: Almacene an on area cublerta y
ventilada a one temperatora qua no sobrepase his
1101F143`C.
Almacenar en forma plaaa. Proteja las lelas del c6ma
cuando las almacene an of lugardetrdbale. No las
almacene cerca de tuberfas da vapor, radfadmes, etc
Requisite do suletador, Use claws do acem
galvanUado, acem Inoxidable o de alaminio, do calibre
12 come mfaboo, con tin dametm de cabera de 18
puig. Owens Coming- recomfenda quo Ins suletadores
cumplan con la norma ASTM F 1667. Cousuhe las
cddigos de construodda locales.
Btencolocado Malcolocado
eEA,mehomfa -
1Rpa13. i i 3/•pdg. T
clap llrpdg Emeblam to
Todos his suldadores deben penetrdrat menus 314
puig. en la plataferma del techo M madera o atravesar
completamente los revestimientris de madera triplay.
Avlsm Owens ComingTM recomlenda el use de clavos
come mdtode prefetldo para f7artelas a superpcfes de
madera u otras supedicles allies para cloves.
1. Tapajuntas especial para elems:
Donde to requiera at vidlpo.
Revestimlento WeathelLockO, o Impermeabi tzame
equivalente para alems ytapaluntas lastalada pasta on
punto de at menus 24 pulp. pasando la Ifnea de to pared
Interior.
Consuh0las Instroalones do Instalachlo del fabdame.
Ver la Fig. 1.
2.Revesttmlento:
Pendiente esMader (4 puig. ada 12 pulgadas o mas)
Insfalacidn del revestimiento, bordes de goteo
metaiices y tpaluntas de alems: Ver to Fig. 2.
(A) Instale one seccidn del revestimiento sabre el
goteron meMlico del alem. UbOce la antldad
estridamente nececada de suletadores para mardemula
an so lugar.
161 Sobreponga las hderas sigulentes 2 pulgadas.
Sobreponga [as extremes de las hileras 4 pulgadas. Las
emoalmes laterales deben esalonarse a 6 pies de
f�
i
FLORIDA PRODUCT APPROVAL FL10674—R5; REFER TO UL CERTIFICATION UPLOADS FOR FASTENING REQUIREMENTS AND
SUBSTRATE LIMITATIONS
3. Undedayment:
Low Slope (2" In 12" to less than 4" in 12")
Application of underlayment, metal drip
edges, and eaves flashing: See Fig. 3.
(A) Apply 19" starter strip of underlayment
over metal drip edge at eaves. Use only
enough fasteners to hold it in place.
(B) Use 36" strip of underlayment for
remaining courses, overlapping each course
19". Side laps are to be staggered 6' apart.
(Cl Apply metal drip edge over
underlayment at rake.
Or WeatherLock® self -adhered
underlayment or equivalent with a standard
over lap of 3 inches and metal drip edge.
See Fig. 3A.
4. Shingle Fastening:
Place fasteners 61/8" from bottom edge of
each shingle and 1" from each end.
Standard Pattern
Use four fasteners. See Fig. 4
Six Nail Pattern
Use six fasteners. See Fig. 4A
Mansard or Steep Slope Fastening Pattern.
Place fasteners 6118" from bottom edge to
secure both layers of the shingle. See Fig. 48.
Shingto Sift Vern
REQUIRED: For slopes exceeding 60 degrees
or 21 inches per foot, use six fasteners and
four spots of asphalt roof cement per shingle.
Apply immediately, one 1" diameter spot of
asphalt roof cement under each shingle tab.
Center asphalt roof cement 2" up from
bottom edge of shingle tab. See Fig. 4B.
Roof Cement where required must meet
ASTM D-4586 Type I or 11(Asbestos Free).
Six nail fastening pattern is required for
Maximum wind warranty. In addition,
Owens Coming— Starter Shingles are
required along the save and rake. (See
Starter Shingle instructions for details.)
5. Shingle Application:
These shingles are applied with a 61W
offset, with 5 518' exposure, over prepared
roof deck, starting atthe bottom of the roof
and working across and up. This will blend
shingles from one bundle into the next and
minimize any normal shade variation.
Application with offsets of 4' or 8' are also
acceptable.
Caution must be exercised to assure that
end joints are no closer than 2' from
fastener in the shingle below and that side
laps are no less than 4' in succeeding
courses. Refer to course application steps
for specific instructions.
Starter Course:
Use an Owens Coming— Starter product or
trim 5 518' from the starter course shingle.
Trim 6 112" off the rake of the starter course
shingle and flush with the drip edge along
the rake and eaves edge, and continue
across the roof. Use 5 fasteners for each
shingle, placed 2" to 3" up from eaves
edge. See Fig. 5. (If no drip edge is used,
shingles must extend a minimum of 1/2"
and no more than 1" from rake and eaves
edge.)
First Course:
Apply first course starting with the full
shingle even with the starter course.
See Fig. 5A.
Fasten securely according to fastening
Instructions. See Fig. 4.
CIM� A A Shingle Application
Fig. instalacidn de tejas
C Shingle Application
:ig. 5c lnstalacidn de tejas
ll&d Course
Tamara MOM
�s
naterda. —.
m�c�`ffidn81`�a tal`0'
to i.✓ra
knedge
Carta npdg,
del6oNenWv a .
Fig.Car ShingleApplication
7E lnstalacidn as tejas
distancia.
ICI Instate el borde de gateo de metal sabre el
G Shingle Application
1g. J instalacibn de tejas
revestimientoenlacomisa.
3. Revestimiento:
Second Comse
Pendlente baja (2 pulg. rada 12 pulg., a means de 4
sEYmfdafdkra
pulg. Carla 12 Palo.)
a ga61Pm0
Instaladdn del revestimlento, bordes de goteo
rvp .
met5licos y tapajuntas de alems: Ver la Fig. 2.
n
(AI Insists Una secclda initial de 19 pulgadas de
55y
revestimlerdo sabre el goterdn metaffco del alero.
Utilice la cantidad estrictamerde necesaria de
e.I.tdge ,
V43 ti*
sujetarlores pars manteneda ensu lugar.
�
101 Use una secci6n de revestimiento de 36 pulgadas
Para el resto de las h8eras, sobreponiendo ada
tillers 19 pulgadas. Los empalmes laterales dehen
Trio s rrr
rmmr.h >s
escalonarse a 6 pies do distancia.
`ass
Ca ev?pdg.dd =• ri�a nouda551apotg.
"
IC) Instate of bards de goteo do metal sabre at
revesdmiento en Is camisa.
Fig. �D Shingle Application
lnsfalaradn de tejas
Fig. SF ShingleApplication
/nsfalacidn de tejas
6 Closed -Cut Valley Construction
Construccidn del valle con torte con -ado
O membrana autoadherente WeatherLock® o
equivalents con una superposici6n estdndar de
3 pulgadas y borde de escummiento. Ver Is Fig.3A.
4.Sujeddn de las telas:
Coloque los sujetadores a 6113 pulg. a partir del borde
inferior do ada tela y a i pulg. de cada extremo.
Esquema estdndar.
Ublice cuatm suletadares. Ver la Fig. 4.
Fsquema con seh davos
Para 6 sujetadores. Ver to H9.4A.
Esquema de Insbbcidn en pendlentes pronandadas o
mansardas
Coloque los sujetadores a 61111 pulgadas del horde
Warier Para ajustarambas spas de la tela. Ver Is Fig.41L
Vua mwar M ra Mra
REQUIS90: Para pendientes de mas de 60 grados o
21 pulg. par pie, utflice sets sujetadores y aatro
canbdades pe(juedas de cememo asfaitado par teja.
Instate inmediatamente una secci6n con 1 pulg. de
diftmetm decemento asfahado debajo de ada Ienglieta
de las telas. Asegdrese de que el cemerdo asfaltado estd
centrado 2 pulg. par endno del bards inferior de Is
lengileta de la tela.
Cuando sea necesado utilizar cements pamtechos, Este
debe cumplkcan to norms ASTM D-4586Tips I611ism
asbestos).
M esquema delijul6n de sets davos es obligatodo parr
Isgarantrarnaftacontra vientos.Ademas esnecesado
Instatar las Islas Para la hilem initial de Owens Coming"
en las comisas detrmpano ylos alem5. (Consults las
Instmcciones de las telas para la hRera InIcIA pars
obtener Wormad6n detallada).
5. lnstalacidn de las telas:
Estas telas se instalan con un desplazamlento de 5 W
pulg., can una supediide expuesta de5518 puig, sabre
platafamias de techas preparada& to coloadOn
comienza par to parts inferiordel techo yse reariza en
forma transversal hada aniba. Be esta manes, las telas
de an paquete se madan con las del siguiente y se
reducen at minimo lasvadadones normales do tonal(dad.
TarnUn se pueden instalar telas can on desplazamiento
de 4 6 8 pulgadas,
Asegdrese de que las unlones de Ins extremas nose
encueitren a menos de 2 pulgadas del sujetador dela
tela que se encaenta mas abalo, y que las
superposidones laterales no sean de menasdo 4
pulgadas en las luleras sigulentes. Cansulte los pasos de
Instalaci6a de hileras pars ver las insuucciones
especifias.
HBem inlciat
Ublice un rollo de inicio o carte 5 516 pulg. de to tela de fa
h0em inicial. Corte 6112 pulg. desde Is viga incknada en
Is tela de la hilera initial yextienda. mas alla de Isviga
inclinada yel horde del alem, y rnMinde a to ancho del
techo. Utflice 5 sujetadares pare ada tela, coloados a
FLORIDA PRODUCT APPROVAL FL10674 r 1 REFER TO UL CERTIFICATION UPLOADS,' -3 FASTENING REQUIREMENTS AND
r
SUBSTRATE LIMITATIONS
Second Course:
Remove 6112" from the left end of this
shingle and apply the remaining piece over 1 Step Flashing
and above the first course shingle and flush Fig 1 Tapajuntas escalonado
with edge of the first course with 5 518'
exposure. See Fig. 59. IaeW Bashing
Fasten securely according to fastening av d
instructions. See Fig. 4. T� fmsd;ni
Third Course: mp.d°r°ng3dxspmlg.m°sd�fir u�aa°xmrow
Remove 13' from the left end of this WPr°�0S 0D
shingle and apply the remaining piece over FVAupedind ,
and above the second course shingle flush°r
with edge of the second course with 5 518' rvoads,.ip°ry
exposure. See Fig. 5C- '
Fasten securely according to fastening --
instructions. See Fig. 4.
Fourth Course: / I
Remove 19 112' from the left end of this ' /"
shingle and apply the remaining piece over
and above the third course shingle and
flush with edge of the third course with
5 518' exposure. See Fig. 5D.
Fasten securely according to fastening Instructions. See Fig. 4.
Fifth Course:
Remove 26' from the left end of this shingle and apply the remaining piece over and above the
fourth course shingle and flush with edge of the fourth course with 5 518' exposure. See Fig. 5E.
Fasten securely according to fastening Instructions- See Fig. 4.
Sixth Course:
Remove 3211T from the left end of this shingle and apply the remaining piece over and above
the fifth course shingle and flush with edge of the fifth course with 5 518' exposure. See Fig. 5F.
Fasten securely according to fastening instructions. See Fig. 4.
Succeeding Courses:
For succeeding courses, repeat first through sixth course- See Fig. 5G-
G. Valley Construction:
Closed -Cut Valley See Fig. 6.
A closed -cut valley can be used as an alternative to woven and open valley and is applied as
follows: Lay, a 36' wide valley liner of self adhered membrane underlayment or equivalent. A
36' wide minimum 50 Ib- smooth surface roll roofing can also be used as a valley liner. Lay all
shingles on one side of valley and across center line of valley a minimum of 12'. Fasten a
minimum of 6' away from center line on each side of valley. Strike a chalk line 2' from the
center line of the unshingled side. Apply shingles on the unshingled side up to the chalk line
and trim, taking care not to cut the underlying shingles. Clip upper comers of these shingles,
cement and fasten. Roth woven and metal valleys are acceptable alternatives.
7. Step Flashing:
Use 10" long and 2" wider than expected exposure corrosion -resistant metal where roof planes
butt against vertical sidewalls or chimneys. See Fig.7.
8- Hip & Ridge Application:
Use corresponding Owens Coming— hip & ridge shingles to best complement shingle color.
Follow specific application instructions as printed on the hip & ridge shingle package.
SeeFig. 8-
8 Hip & Ridge Application
Hip,
de cabailetes yaunbreias
na° "w®duierm
EV—
Dic iuodAee,P°prtdm,ue°f°
EV
4�
una distanda de entire 2 y 3 pulgadasdel borde del alero.
Ver Is Rg. 5. IS] no uIlliza on horde its poteo. List"
deben extenderse, on minlmo de 112 pulgada y on
m9xlmo de 1 pulgada de Is viga Indinada y at borde del
alarol.
Pdmerahilem
Coloque Is primers Went comenrando con Is Isla enters
alineada con Is hilera laical. Ver Is Rg. W Sujete
firmemente de acuerdo con las instmcciones de suWidn.
Ver Is Rg. 4.
Segundah0em
Quite 612 pulg. del borde izquierdo its esta Isis y aprique
Is plaza restante sabre y porendma its Is feja de Is
primers fillers y all ras del borde de la primers hfeM con
5 5t8 puig, de exposicidn. Ver Is Fig. 5B. Sujete
firtnemerde de acuerdo can las inshuccfones de sujecida.
Ver Is Rg. 4.
Tercera hUara:
Quite 13 palg. del horde izgaierdo de esta taja yaprique la
plaza restante sabrey par encima de Is teja de le segunda
hilem y al ras del borde de la segunda hfera, can 5 518
pulg. de exposiddn. Ver Is Fig. 5C. Sujete firmamente de
acuerdo can las Insirucciones de sujecido. Ver Is Fig. 4.
aria Mora:
uite 1912 ping. del horde izquierdo deesta teja y aprique is plaza restante sabre y par errdma de Is teja its U temem fillers V at
s dell borde its la terraria hilera, con 5 5r8 pulg. de exposicidn. Ver Is Fig.50. Sujete firmemente de acuerdo con las inAmcciones
sujedim. Ver Is Fig. 4.
uluta Meur
uite26 puig. del borde tzquierdo de, esta teia y aplique la plaza restante sobrey porencuna de Is teja de Is cuada Nora Val ras del
Ne de to cuarta lulera, can 5 511 ping. de exposicidn. Ver la Rg. 5E Sujete fnimemente de acuerdo con las lnstruccones its
s ijecl6n.Verla Rg. 4.
a h8era:
Wile 3212 puig. del borde tzgoierdo de estateja yapiique Is plaza restante sabre V par encima de la tela de Is quints idlers Val ras
I borde de la quints biters, can 5 518 pulg. de exposiddn. Ver Is Fig. 5F. Sujete famemerde de acuerdo con las insbucclanes de
s ijecidn. Ver la Fig. 4.
eras sigulerdes
no In hfleras sigutentes, repita Ins pasos qua se inddcan desde Is primers basis Is sexta Were. Ver la Fig. SG.
LConstmcd6n deivafe:
e ceaado VerFjg.6.
Un valle con code cerrado posits ser usado coma ahemafiva a on valle tejido o abiertoy se colors de to sigularde manes
Cotoquean el valle on impermeabilizante autoadhesivo a equivalents con 26pulgadas de ancho. Para revestir el valie,tambien se puede
Ldiftaron rollo de techado its 36 pulg. de ancho y on minimo de 50libras. Coloque todas las tejas sabre on )ado dal va0e y a trai de Is
Ilnea central del va0e al mans 12 putgadas. Sujete a on minimo de 6 putgadas de to Unea central a rada lado del valle. Marque Una lines
de tiza a 2 putgadas de to lines central del lado qua nofeneteias. Coloque las tejas del lado qua no tiene Islas basis Is Unea de fza V
reoute, con cuidada its no cortar [astejas quo se encuerban debajo. Una Ins extremos superiores de estastei coloque cemento y
Sujete Se pueden uill®rvalles detejidoo metal.
7 Tapajonlasestalonado:
ice metal rssisiente a la ourrosidn con Una exposicidn its 10 putgadas de longitud y do 2 putgadas mds de andio qua to
osictdn esperada an ins pumas an los qua las pianos del techo se iman a las parades laterates vadicales o a chimeneas-Ver Is
9.7-
ApUeaddn pars caballete v cumbrers
M ce tejas pars cabaltetes y cumbrerds. Stga las instrucdones de instalacidn del paquete de caballetes V cumbrems. Ver Is Fig. R