HomeMy WebLinkAboutSUBMITTED PAPERS1�;x.Zia • ��
DATE: FEl`•
1. Location/Site Address:
RECEIPT #:
Permit #:
(O
Planning & Development Services Department
Building & Code Regulation Division
GAIyNE�
2300 Virginia Avenue
Ft. Pierce, FL 34982-5652 BY
Tel.a7i4 -1553 St LUCIe QQ�Inty
APPLICATION FOR ROOF PERMIT
SEE REVERSPF SIDE FOR INSTRUCTIONS
2. Parcel ID Number: ,_3-�,/ 9 n; Q - !: 46, - non. -7
.k,
Office Use
Only
Sectio:n:::J::T:ownship
Range
Map Page
Zoning
Land Use
Initials
3. Description of Project or Work Activity:
4.
Total Roof Area (square feet): Z&OLD
6. Type of Roof: [ ] Fiberglass Shingle
[ ] Tar & Gravel [ ] Modified Bitumen O er
[4q Product Approval required for all types of Roofing Material F Se
i
[ ] All Commercial Roofmg requires design by an Engineer or Architect (2 Sets) with Product
[ ] Concrete Roof Tile
5. Roof Pitch: / 5 //-:2-
[ ] Wood Shake / Shingle
Approval attached
** Roof Mitigation per F.S. 553.844 will be required.
7. Owner Information 8. Contractor Information
Name: T 0 A t (JY1 1 A- I' �W WS k(�
Address:
City: State: CL
Zip: Phone: Jib /3
3
FL Reg/Cert #: L CA 15 a 4-e-z-1 `7 —7
County Cert #:����
Business Name:,,/,��91-1 �2 40A 11 /L�p
CellPhone: 2l �lo BDZ�
9. Value of Construction: $ �] Q(p o.Cp
"Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval.
CONTRACTOR/OWNER'S AFFIDAVIT: I certify, that all of the information contained in this application is correct and that all work will be
done in co 'ance with all applicable laws regulating construction and zoning.
PRINT Q ALIFIERS/OWNERS NAME i9lbNATURE OF QUALIFIER/OWNER
STATE OF FLORIDA, COUNTY OF 5 c
ACKNOWLEDGED BEFORE ME T� HIS DAY OF 20 1 ,BY
O IS PERSOJ`TALLY OWN ✓ TOME OR PRODU D p18ERT
MY COMMI SSION 0 DD837776
SI ATURE OF NOTARY TYPE OR PRINT NAME OF NOTARY EJCpItFq. N November 1As = CO,1.900-3•NOTARY Notary Dismount Assoc. �
COMMISSION NUMBER
NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE
FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
Revised 4/26/2010
JOSEPH E. SMITH, CLERK OF THE CIRCUIT COURT - SAINT LUCIE COUNTY
FILE # 3657364 OR BO(`�348 PAGE 1335, Recorded 12/16/2011 -)1:02 PM
NOTICE OF COMMENCEMENT
The undersigned hereby given notice that improvement will be made to certain real property, and in accordance with Chapter 713,
Florida Stames the following information is provided in the Notice of Commencement
I. DESCRImoNN OF PROPERTY (Legal description and street address, if available) TAx FOLIO NUMBSR�, �{ Ski/' /(A(l Cyro •7
SUBDIVISION tR V[rJOQf/e BLOCK _�_TRACT I,011--�2 BLDO UNrr
c�//gll��'
2 OENERALDP�BpNOPD1RROvfCMLNT: �FL
�i.. n..Cv�,l.4�i�is.c�z.il�Cp fr'"X 0 iA%?7 ahr .�rkzp-'/ArA P 3�/9P3
3. OwNERINFORMATIoN:
ramwieProputy Ota)A!G R
d N.me.ad addrer arlm �mpte4dehddaQraMchhaa oYmc)
4. CoNTRAcroirs NAw ADDRrssANDPHoNmIlumER.• A 11_ rrIA11. Yfno
5. SURLrY'SNAM7,
6. LENDER'S NAME, ADDRESSAND PHONE NUMBER:
7. Persons wjthin the State of Florida designated by Owner upon whom notices or other documents may be served as provided by.
Section 713.13 (1) (a) 7., Florida Statutes:
NAME, ADDRESS AND PHONE NUMBER:
I. In addition to himself or herself, Owner designates the following to receive a copy ofthe Lienoes Notice as provided in Section
713.13 (1) (111 Florida Statutes:
NAM>Z.ADDRESSAND PHONE NUMBER:
9. Expiration date of notice of commencement (the expiration date is 1 year from the date of recording unless a different data is
specif➢ed$ _; 20
.
rc I
9
1212812011 09:16
1 '
r ,
i
(FAX) .,
P.0021002
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, Fl. 34982
772-462-2165 or 772-462-2172
Fax: 772-462-6443
ROOF INSPECTION AFFIDAVIT
Re: Permit # Wa—wo(p
I, ( i kKLF-- 5 }Cd lz-b 4 , licensed as a(n)Contractor*/Engineer/Architect
(Please print name & circle license type) *FS468 Building Inspector
*General, Building, Residential or Roofing Contractor or any individual certified under 468 F.S. to make such an inspection.
On or about �� ( I did personally inspect the roof deck nailing
(Date) `
work at: 1 � SF �� GL �'�� , �D I✓ �C .e-�L.-� ( L �
(Job site address)
Based upon that examination I have determined the installation was done according to the Hurricane
Mitigation Retrofit Manual (Based on 553.844 F.S.)
Signature and Seal
CCC 132C 1 Tj
License #
STATE OF FLO 1,DA
COUNTYOF
26.
Sworn to and subscribed before me.this day of 20
by CAV1)rk) ik JC4—yl r 4Who is personally known to me o +�s*asjrreVMd
as identification.
Notary Public, State of1Fridawo,.�z,,,�,
Signature of Notary \ �"SY •iENNIFER O
�a MY COMMISSION # DD83777b
Commission Number. (SLI-NDTARY
�IRFS:MO—ba12,2012
fl. NOWY Disepum As,= co.
En 01/19/2011 ` -' vv'
- r
®IEC 2 2011
public \forks
FL
St. Lucie County,
FILE COPY.,
ENGINEERING & TESTING, INC.
Phone: (866) 781-6889 •Fax: (866) 784-8550
iiivw.floridaengineeringandtesting.com
250 S.W.13"' Avenue
Pompano Beach, FL 33069
DATE: 12/16/11 JOB ORDER #: 11-2933
CLIENT: All Area Roofing
ADDRESS: _ 3921 S. US Highway 1 Fort Pierce, Florida 34982
PROJECT: Beniamin Dombrosky Residence 5V Crimp Metal Panel
ADDRESS: 184 S.E. Celestia Court Port Saint Lucie, FL 34983
ASCE 7-05 DESIGN PRESSURE CALCULATIONS
Proiect Information:
Height = 9' Exposure: C Basic Windspeed: V=140 mph
Length = 5l' Category: II Importance Factor: I=1.0
Width = 37' Slope: <7° KZ = 0.85, Kd = 0.85
Parapet Wall: < 3'
Design Calculations:
Velocity Pressure: q = 0.00256*[(0.85)(1.0)( 0.85)(140)2(1.0)] = 36.25 psf
Width of Pressure Coefficient: 0.1(3T) = 3.7'
0.4(9') = 3.6' ) use: 4'0"
Effective Wind Area: <1Oft2
For parapet height three feet (T) or larger, zone three (3) can be treated as zone two (2)
(ASCE 7-05).
External Pressure Coefficient:
1)
GCP1
= -1.0
2)
GCP2
= -1.8
3)
GCP3
= -2.8
Internal Pressure Coefficient:
1)
1r �
X,f
Quality \'A jy. 8wfrance
GCPi = 0.18
w e ,
Page 2
12/16/11, Job Order # 11-2933
All Area Roofing
Benjamin Dombrosky Residence - 5 V Crimp Metal Panel
184 S.E. Celestia Court; Port Saint Lucie, FL:
Design Pressures:
1) Field
2) Perimeter
3) Corners
Attachment Requirements:
P1 = 36.25*[(-1.0) — (0.18)] _ -42.8 psf
P2 = 36.25*[(-1.8) — (0.18)] _ -71.8 psf
P3 = 36.25*[(-2.8) — (0.18)] _ -108.0 psf
Based on the requirements of Florida Product Approval FL # 12076.1 with a maximum
design pressure of-131.lpsf at fastener row spacing of 6"o.c.; the following are our
recommended panel attachment for the 24" wide 5V-Crimp Metal Panels with (5) 1/2"
high ribs with # 9 x 2" wood screws with self sealing washers:
Field Fastener Rows Spaced at a Maximum of 36" o.c.
Perimeter Fastener Rows Spaced at a Maximum of 36" o.c.
Corners Fastener Rows Spaced at a Maximum of 36" o.c.
Install Fasteners per Typical Panel Installation X-Section on Drawing No 1707-1, Sheet 1 of I
Notes: Corners and perimeter area dimension shall not be less than a = 4'0"
Contractor to verify that the fastening patterns meet manufacturer's
requirements for issuance of a warranty (as applicable).
All work shall be in compliance with the local building code product
control notice of acceptance and manufacturer specifications and Florida
Building Code 2007 Edition.
Wind load calculations based on ASCE 7-05 and information provided by
client.
All work shall be inspected by our field engineer (or authorized
representative) or a city inspector to verify compliance with specifications.
Sincerely,
Mark A. Mesiano, P..E. _
Florida Engineering& Testing, Inc.
Florida Reg. No. 48202 -
Certificate of Authorization No. 6923
��.;� F �`� �•�g$,s `fir a �z46 ��� �✓r s', 'y��«`.,s"`� 1 / [ 'bs+'knv+.am ;"�
Fit lda tRprii mento BCIS Home Log In User Registration i Hot Topics I Submit Surcharge Stats & Facts i Publications i FBC Staff BCIS Site Map i Unks i Search
Business
Professi�a� �1,•„
1 Product Approval
I" lJ��"�� t� USER: Public User
Regulation
Product Aooroval Menu > Product or Application Search > Application List > Application Detail
FL #
FL12076-111
Application Type
Revision
Code Version
2007
Application Status
Approved
Comments
Archived
t l
Product Manufacturer
Metal Sales Manufacturing Corporation
Address/Phone/Email
545 South 3rd Street, Suite 200
Louisville, KY 40202
(812) 218-7342
dstermer@metalsales.us.com
Authorized Signature David Stermer
dstermer@metalsales.us.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
L Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who Bala Sockalingam
developed the Evaluation Report
Florida License PE-62240
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 02/10/2014
Validated By Yoosef Lavi, P.E.
R1 Validation Checklist - Hardcopy Received
Certificate of Independence FL12076 RI COI CertificateIndePend ence.odf
Referenced Standard and Year (of Standard) Standard Year
ASTM G155 2004
FM 4470 1992
TAS 125 2003
UL 1897 1998
UL 580 1994
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
05/03/2010
Date Validated
05/10/2010
Date Pending FBC Approval
05/17/2010
Date Approved
06/08/2010
of Products
FL # IlModel,
Number or Name IlDescription
12076.1
5V-Crimp
26 ga., 24" wide through fastened roof panel over
plywood deck
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL12076 R1 II D1707 01.pdf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-131.1
Evaluation Reports
Other: 41.6 psf @ fastener spacing of 36" oc and 131.1
FL12076 RI AE EValuationReportC1707 l.pdf
Created by Independent Third Party: Yes
psf @ fastener spacing of 6" oc
12076.2
Clas is Rib
Min 29 ga., 36" wide through fastened roof panel over
plywood deck
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL12076 R1 II D1707 02.Ddf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-138.5
Evaluation Reports
Other: 68.4 psf @ fastener spacing of 24" o.c. and
FL12076 R1 AE EvaluationReportC1707 2.pdf
Created by Independent Third Party: Yes
138.5 psf @ fastener spacing of 12" o.c.
eacic Next
Contact Us :: 1940 North Monroe Street. Tallahassee FL 32399
The State of Florida is an AA/EEO employer. Copyright 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, e-mail addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not
send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions regarding DBPR's ADA web
accessibility, please contact our Web Master at webmaster(a)dbpr.state.fi.us.
Product Approval Accepts:
® e0iM
5CCUr1LVIALT RICE
verislgn
Trusted ,
vewr—
PANEL
ROOF PANEL (REF. NOTES
& PANEL DETAIL)
\ SEE DETAIL 2
-(SEE DETAIL 1
BD x 2.5" LONG RING SHANK NAIL
OR #8 x 2" LONG WOOD SCREWS
SPACED ® 6" O.C. IN THE FIELD &
AT PLYWOOD EDGES
FASTENER AT PANEL FLAT
REQUIRED FOR PANEL
ENDS ONLY.
UNDERLAYMENT SHALL BE INSTALLED \- MIN. 2X_ WOOD RAFTER/JOIST/
AS PER MANUFACTURERS INSTALLATION TRUSS AT X 4
GUIDELINES TYPICAL PANEL INSTALLATION X- S ECTI O N
#9 X 2" WOOD SCREWS
WITH SELF SEALING WASHER
UNDERLAYMENT
J10 v 0" w— cr—
I INf1FPI AN
DETAIL 1
DETAIL 2
26 GA. PANEL
PLYWOOD
19/32" THICK (MIN.)
5 GA. PANEL
_ 'WOOD
19/32" THICK (MIN.)
PANEL FASTENER PER ALLOWABLE
PRESSURE TABLE ON THIS SHEET.
ALLOWABLE UPLIFT PRESSURE
FASTENER
PRESSURE
SPACING
(PSF)
(IN)
36
41.6
6
131.1
GENERAL NOTES:
1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE
FLORIDA BUILDING CODE (FBC).
2. ALL ROOF PANELS ARE SHALL BE 25 GA. (t = 0.0169"). EFFECTIVE COVERING
WIDTH OF PANEL = 24".
3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS
SPECIFIED ON THIS DRAWING.
4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS
PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS
ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING.
5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA
BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM
REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL.
6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS
REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS.
0
No
F, N
W
a �N
NOO
M
W my I
o N
n� I
y =y O
lJjyJ 0
�o
�Ln
0 LO
t
O O x
O0 p u n
a a yem
z =gyp
u
a
z1O
U
OW
i '^d
OF
EVALUATION REPORT OF
METAL SALES MANUFACTURING CORPORATION
`26 GA. 5V-CRIMP PANEL'
FLORIDA PRODUCT APPROVAL
#FL 12076.1.-Rl
ROOFING
METAL ROOFING
Prepared For:
Metal Sales Manufacturing Corporation
545 South 3rd Street, Suite 200
Louisville, KY 40202
Telephone: (502) 855-4300
Fax: (502) 855-4290
Prepared By:
Bala Sockalingam, Ph.D., P.E.
Florida Professional Engineer #62240
1.216 N Lansing Ave., Suite C
Tulsa, OK 74106
Telephone: (918) 492-5992
FAX: (866) 366-1543
This report consists of
Evaluation Report (2 Pages including cover)
Installation Details (1 Page)
` SOCKAL
Report No. C1707-1 No. 62240 •��
Date:5.3.10 70 * 115
S� �7A7E OF` 2
S. 3. 10
G •
Manufacturer:
Product Name:
Panel Description
Materials:
Deck Description:
Deck Attachment:
Underlayment:
Slope:
FL #12076.1-R1
C 1707-1
5.3.10
Page 2 of 2
Metal Sales Manufacturing Corporation
5V-Crimp Panel
24" wide coverage with (5) 1/2" high ribs
Galvanized coated steel (ASTM A653) or Galvalume coated steel
(ASTM A792) or painted steel (ASTM A755). Minimum 26 ga., 50
ksi steel.
19/32" thick plywood
8d x 2.5" long ring shank nails or #8 x 2" long wood screws @ 6" o.c.
in the plywood field and edges
, Minimum underlayment as per FBC 2007 Section 1507.4.5
1/2:12 or greater in accordance with FBC 2007 Section 1507.4.2
Design Uplift Pressure: 41.6 psf @ fastener spacing of 36" o.c.
(Factor of Safety = 2) 131.1 psf @ fastener spacing of 6" o.c.
Fastener Pattern:
At panel ends #9 x 2" long SDS @ 6" o.c. across panel width
At intermediate #9 x 2" long SDS @ 12" o.c. across panel width
Test Standards: Roof assembly tested in accordance with UL-580-94 (Rev 98) `Uplift
Resistance of Roof Assemblies' and TAS 125-03 `Standard
Requirements for Metal Roofing Systems'.
Code Compliance: The product described herein has demonstrated compliance with FBC
2007 Section 1507.4
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2007 Section 1609. The maximum fastener spacing listed
herein shall not be exceeded. This product is not approved for use in
the High Velocity Hurricane Zone.
Supporting Documents: TAS 125-03 & UL-580 Test Reports
Farabaugh Engineering and Testing Inc
Project No. T181-05, Reporting Date 7/21/05 (Tests #1 & 2)
Project No. T284-08, Reporting Date 11/19/08
ASTM G 15 5 Test Report
PRI Construction Materials Technologies
PRI08013, Reporting Date 5/12/08