Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSVr_i OFFICE U:+-E ONLY: --Receipt# I - Permit V, ALL INFO MUST BE COMPLETE & FILLED IN. TO BE ACCEPTED . . . . . . . . . . St. Lucie County Building and ZoWni 2300 Virginia Avenue Ft. Pierce, FL 34982-5652 C_ 772-462-1553 St By C/ APPLICATION 6ROA-LUMINUM STRUCTURES PERMIT PROJECT INFORMATION 1. LOCATION/SITE ADDRESS: 8918 FIRST TEE ROAD, PSL, FL 34986 2. PROJECT NAME: RESERVE KINGSMILL SITE PLAN NAME: 3. PROPERTY TAX ID 3334.500.0075.000.6 4. LEGAL DESCRIPTION (attach extra sheets if necessary): POD 33 AT TEH RESERVE P'HASE. 1 KINGSMILL LOT 64 (OR 1461-1566) 5. PLAT 6. PAGE 7. BLOCK 8. LOT BOOK NO. NO. No. 64 ,9. PARCEL SIZE: ACRES/SQ FT. to. LOT DIMENSIONS 76 -7. 0 r SIDE: SETBACKS (ACTUAL) FRONT--�r BACK:23..7& RIGHT LEFT SIDE, lo. —N-1-6- ll. TYPE OF STRUCTURE (CHECK ALL APPROPRIATE BOXES FOR EACH -AND EVERY TYPE OF STRUCTURE) N=New SG = Slab on Grade SQUARE FEET OF TYPE OF CONSTRUCTION A= Addition SR = Raised Slab DIMENSIONS CONSTRUCTION R = Rebuild WD = Wood Deck SCREEN ROOM NEW EXISTING X JZI ❑ CARPORT/PATIO ROOF ❑ NEW 1:1 EXISTING X El HABITABLE GLASS ROOM ❑ NEW 0 EXISTING X 1-1 SUNROOM El NEW F-1 EXISTING X El SHED ❑ NEW El EXISTING X CO POOL ENCLOSURE El NEW El EXISTING X El MHROOFOVER El NEW 0 EXISTING X El ROOF SYSTEM OVER 11 NEW El EXISTING X EXISTING ACCESSORY STRUCTURE OTHER: 1-1 NEW El EXISTING X 0 POOL FENCE Linear feet TOTAL SQUARE FOOTAGE OF CONSTRUCTION o�— Z 2 12. VALUE OF CONSTRUCTION: $ -(e coo -&a The value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of cofistructipn,activities. If the value is $2500 or. moke,,.d RECORDED Notice of Commencement must be submitted PRIOR TO FIRST I&SPEttio,14.. 8LCCDVForinN4.:001-02 Rep-31112009 INFORMATION a. IOWNER NAME: ACe fA yr"---S5 ADDRESS- e Asks 7 Zj 0. CITY:- I'OC')A'f 51r w G FL STATE: ZIP 'PHONE-(DAYiIME)-'4?'23 eK2 20nra. EMAIL: FELL IN NAME AND ADDRESS BELOW IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE:& FEE SIMPLE TITLEHOLDER: ADDRESS: CITY: STATE: ZIP PHONE (DAYTIME): CONTRACTOR INFORMATION CBC1264009 25678 STATE OF FLORIDA REG./CERT #: ST. LUCIE COUNTY CERT BUSINESS NAME: . FLORIDA SCREEN BUILDERS INC QUALIFIER'S NAME: RENE M CANTIN . 3269 SW 42ND AVENUE ADDRESS: CITY: PALM CITY STATE: FL ZIP 34990 PHONE (DAYTIME): (�561) 602-7328 FAX NO.. 1561-753-7634 email: floridascreenbuilders@comcast.net ARCH1TECT/ENGINEER:--'.-. ADDRESS: CITY: STATE: ZIP PHONE (DAYTIME): NOTE: IF APPLICABLE, SUBCONTRACTOR AGREEMENTS MUST BE ATTACHED TO APPLICATION FOR ROOFING, ELECTRIC, PLUMBING, AND HVAC ZONING REQUIREMENTS All such structures*fll be subject to the requirements of the'ST. LUCIE COUNTY LAND DEVELOPMENT CODE. ❑ 2 scaled plot plans showing lot size, dimensions of existing host structure, and proposed aluminum addition. All setbacks including front, side, rear and distance between adjacent property structures in MH Parks shall he indicated on the plot plan. El 2 sets of color photos for all storm damaged areas to be reconstructed. One picture must include house address number for inspection verification. not required for construction unrelated to storms) OFFICE USE ONLY SECTION cd TOWNSHIP' RANGE MAP NO ZONING pn LAND USE --DC, LOT CVG % Additional Permits Re uired REPORT li' BIMS FEE $ MISC FEES TOTAL FEES $ CODE BUILDING &ZONING REVIEW FRONT PLANS VALUE OF CONSTRUCTION REVIEW COUNTER ZONING SUPERVISOR EXAMINER VEGETATION USING ICC TABLE DATE UUINII-L'EIrl INITIALS J PLAN REVIEW SPECIFICATION CHECKLIST PLEASE PROVIDE ONE OF THE FOLLOWING: ❑ 2 Sets of Detailed Plans: Dated, Signed & Sealed by an Engineer or Architect holding a Florida State professional license. ❑ 2 Sets of Detailed Plans: Designed in accordance with the AAF Guide to Aluminum Construction in High Wind Areas. ❑ 2 Sets of Detailed Plans: Designed in accordance with any Approved Manual per fs-489.113. (I) ANY PLANS SUBMITTED WITHOUT COMPLYING WITH THE FOLLOWING SHALL BE RETURNED WITHOUT APPROVAL. ALL PLANS MUST BE IN INK AND ANY NOTATIONS IN PENCIL WILL NOT BE CONSIDERED A PART OF A SUBMISSION. • All plans must be legible and must be designed in Architect's Scale on pages which are 81/2" x 11" or larger. • All relevant tables & details, if using a manual, must be properly highlighted and must match design checklists & drawings. • The plan view must include all dimensions; the location of the host structure and all materials must be sized and identified thereon. • All elevations must be shown, including 4`h wall detail, dimensions and all material must be sized and identified. • All primary and secondary carrier beams, spans, spacing, gauges must be shown [Example: 2" x 8" x .072"]. • All methods of fastening or other details which are relevant to the design must be identified on the Plans. • All upright column heights, sizes, spacing and gauges must be shown as follows: [Example: 3" x 3" x .050"]. • All chair -rails, roof purlins, girts, channels, knee -bracing, k-bracing, cable bracing or any other required component must be sized and identified. • All ridge beams and super gutter or fascia attachments must be identified. • All roof pans or composite panels, with gauges and spans, must be sized and identified. • All footing, slab and ISO pier designs must be on the plans, per the Architect / Engineer's plans & specifications. • All light metal alloys which are utilized shall be designed in conformity with the Florida Building Code of 2007, Chapter 20, including 2006 revisions. Barrier railings, if utilized, shall have all materials, fasteners and height specified and shall have self -closing, self - catching gates with picket spacing. (II) SITE CONSTRUCTED SHEDS, HAVING ANYALUMINUM COMPONENT, SHALL MEET ALL OF THE ABOVE REQUIREMENTS AND THE FOLLOWING ADDITIONAL ITEMS: (A) 2 copies of the current product approval [i.e. N.O.A. or State of Florida approval] with the proposed "opening" or cladding component highlighted and with fasteners and design pressures, per FBC 1714, clearly identified. (B) 2 electric schematics, in accordance with the N.E.C., if applicable. (C) Design pressures, per ASCE-7, identified on the openings of all Plans. (III) HABITABLE ROOMS/ADDITIONS DESIGNS SHALL MEET ALL OF THE ABOVE REQUIREMENTS, EXCEPT AAMA SPECIFICATIONS, AND CHAPTER 13 OF THE FLORIDA BUILDING CODE. (IV) SUNROOMS (as defined in R202 and FBC 2002.6) MAY BE CONSTRUCTED, SO LONG AS THEY MEET ALL OF THE ABOVE REQUIREMENTS AND MUST BE IN STRICT COMPLIANCE WITH AAMA/NPEA/NSA2100.02 AND MEET THE FOLLOWING ADDITIONAL ITEMS: (1) The designer or engineer will state on all Plans, which Category of Design [3.1.2] will be used, inclusive of the definition. (2) If designing a Category 4 or Category 5 structure, as defined in the current Edition of 3.1.2.4 and 3.1.2.5, proper energy calculations and long form equipment sizing calculations shall be required, pursuant to Chapter 13 of the current State of Florida Building Code. (V) MOBILE HOMES (FAC 15C-2.0081 - FAC 15C-2.0072): ALL STRUCTURES ADJACENT TO OR NEW ROOF SYSTEMS (Pan or Composite) OVER EXISTING ADJACENT STRUCTURES TO A MOBILE HOME SHALL REQUIRE: (a) A 41h wall or a current, signed original manufacturer's attachment approval letter which includes the model number, serial number and current owner's name and street address. (b) That the complete guide to H.U.D. specifications be strictly adhered to. (c) A Certified Florida Engineer may design the manner of attachment of the proposed structure to the host house but shall assume full responsibility for both structures' integrity by site specific documentation. 0 Y CERTIFICATION: This application is hereby made in order to obtain a permit to do the work and installations as indicated, and to obtain a certificate of capacity, if applicable, for the permitted work. NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR_ IMPROVEMENTS..TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT, NOTICE TO APPLICANT: IN THE EVENT IT IS NOT YOUR RIGHT TITLE OR INTEREST THAT IS SUBJECT TO ATTACHMENT, THE, APPLICANT DOES HEREBY MAKE A GOOD FAITH PROMISE TO DELIVER A COPY OF THE ATTACHED CONSTRUCTION LIEN LAW NOTICE TO THE PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT, AND DOES SO AS A CONDITION PRECEDENT TO THIS PERMIT 1. If utilizing the AAF Guide to Aluminum Construction in High Wind Zones, I the Contractor/Owner Builder hereby certify _ that the components'being used, fasteners type and fastening pattern meet all the requirements for the designated wind zones established by the county and take full responsibility for complying with the submitted design of the structure being permitted. 2. I further certify that all the foregoing information is accurate, that no work or installation has commenced prior to the . issuance of a permit and that all work shall be performed in compliance with all applicable laws regulating construction and zoning in this jurisdiction. I understand that separate permits may be required for ELECTRICAL, and HVAC, etc., not otherwise included with this building permit application. 3. I , the Contractor / Record and is in ade, exceed the footprint OWNER w Builder, have verified that the existing foundation meets the eq condition to withstand the uplift and weight of the aluminu uctu structure that was in existence prior to removal by the sto �J SIGNATURE CONTRAWR SIGNATURE STATE OFRIDA COUNTY The foregoing instrument was acknowledged before me me this Z)day of , 20 ff , by ' RENE M. CANTIN ements of the Engineer of and said structure will not STATiPF FLORIDA ®G.IyJ COUNTY OF 44crve The foregoing instrument was acknowledged before me me this day of , 20�_, b RENE M. CANTIN Y, who is personally known X to me, or who has who is personally known X produced , produced as identifliretibipi / M as WENDY LOUDERBACK OOMMI&do # DD949086 EXRIRFB December 28, 2013 IMPORT. to me, or who has W NDY LOUDERBACK , 4Y COMMISSION 49086 EXPIRES December 28, 2013 • TWO (2) SIGNATURES ARE REQUIRED. EACH SIGNATURE MUST BE NOTARIZED. IF APPLYING FOR THIS BUILDING PERMIT AS AN OWNER/BUILDER, THE OWNER MUST PERSONALLY APPEAR, IN THE OFFICE LISTED ON THE FRONT OF THE APPLICATION, TO SIGN THIS APPLICATION & THE OWNERBLDR AFFIDAVIT. • ALL SIGNATURES ON APPLICATION SUBMITTED SHALL BE ORIGINAL, SIGNED IN INK. COPIES_ , FAXES, OR STAMPED REPRODUCTIONS ARE PROHIBITED. • WHEN A PERMIT IS AVAILIBLE FOR ISSUANCE BUT IS NOT PICKED UP WITHIN THIRTY (30) DAYS AFTER NOTIFICATION OF AVAILIBILITY, IT WILL BE VOIDED. IF THE APPLICATION IS RESUBMITTED, AN ADDITIONAL FEE WILL BE CHARGED. :'�, - - i, 01/30/2012 10:08 772-286-6056 FSB SHOP-FLORIDA SCREEN BUILDERS #3400 P.001/001 J=PH E.. SMITH, C' OF THE CIRCUIT COURT - SA=T LUCIE COUti+_ FILr # 3662*378-FOR BuuX 3352 .PAGE 2467, Recorded 01/05/2012 aL v3:26 PM s8;dwwm�ei� Days DESIGN CRITERIA -2007 F.B.0 -PER ASCE 7-0.5 -WIND ZONE=140 MPH -EXP B -IMPORTANCE FACTOR .77 - APPLIED UNIT LOADS, COMPONENT DETAILS AND FASTENING REQUIRMENTS AS PER THE ATTACHED 2007 AAF DESIGN SPECIFICATIONS. APPLICABLE DETAILS ARE MARKED AS SHOWN AND ARE TO BE PART OF THE SITE SPECIFIED DESIGN CRITERIA FOR FABRICATION AND INSTALLATION. EXISTING COVERED PORCH 1. 13'-0 1 STEP OUT AS REQUIRED TO ALLOW CLEARANCE FOR THE ACCORDION SHUTTER co I I I I I 1 2X2 � 1 I N ` ' 2X2 N � r ` I (� I I I I 5" SUPER GUTTER ,I I ,co x co ch I 2x8 SMB M .J ' i ` T-03/a" 11-411 Rpm I L Py in ,LOU ---------- ---------------------------------------- ------------------------------------------------- 14'-11'/2" T-0'/" 2x3 (TYP) m ch m N � N U) M N N 6'-4" 11 6'-4" N 0o N 0 2x8 SMB ST. LUCIE COUNTY BUfLDING DIVISION REVIEWED FOR C L T E REVIEN `ED Y DATE - '?/ isL,.��S s ti I'E: b1IT i1L.-5T BE Ii�PT OIV JC'T DR NO EtiSPECTION «VILL BE MADE. DETAIL NOTES: COLOR: BRONZE ROOF SCREEN: BETTER VUE WALL SCREEN: BETTER VUE WALTER & PHYLLIS MCKEE 8918 FIRST TEE RD PORT ST LUCIE,FL 34986 772-812-6706 2x3 (TYP) FLORIDA SCREEn BUILDERS inc o BUS: 561-753-7734, FAX: 561-753-7634 M 3269 SW 42 AVE, PALM CITY, FL 34990 EMAIL: floridascreenbuilders@comcast.net WEBSITE: floridascreenbuilders.com EXISTING 4" CONCRETE PATIO SLAB STATE LICENSE: CBC1254009 Chapter 1- Screen Enclosures 1) Design pressures taken from Table 2002A, Florida Building Code 2007 with supplements thru 2007. 2) Extrusions assumed to be alloy 6063T6 unless noted otherwise. 3) Drawings and Details are typically schematic and should not be scaled. 4) Far "half mansard" roof configuration, use beam table 101 for mansard shape. 5) "Approved Masonry Fastener" for connection to foundation must meet the following specifications for 2 �'A" embedment into 2,500 psi (minimum) concrete: a. 3/8" 0: allowable tension 1,055 #, shear 1,716 # b. 1/4" 0: allowable tension 567 #, shear 394 # 6) For mansard beams, connection at host end of beams (i.e. fascla/gutter) height must be equal or greater than the eave height of the enclosure. 7) Tables which have numeric entries versus scalar variables (e.g. spans vs. load widths, or spans vs. wail heights) may be interpolated. CARRIER BEAMS IN SCREEN ENCLOSURES: 1) Carrier Beans (Refer to schematic diagrams for limitations) must be horizontal and may not exceed a single span of 16 R. 2) At least one end of carrier beam must be supported by the host structure. 3) Allowable load widths for carrier beams on Table 112 with accompanying schematic diagram 4) Connect 2x8 SMB post/column at foundation using Detail C2 Concrete Cover: For foundations, minimum concrete over reinforcing bars shall be 3 inches in foundations where the concrete is cast against and permanently in contact with the earth. For No. 5 and smaller bars 11/2" where concrete is formed and will be exposed to the earth or weather. Where concrete is not exposed to weather, the minimum concrete cover for reinforcing shall be 11/2 inches regardless of bar size. Table 2002.4 DESIM WIM PRESSMES SCREMM ENCLOSURES EKPOSURE B (FOR MEAN ROOF HII:IQRS LIP T030 FF) Basic Wind Speed (mph) Design Pressure (psf) Surface 100 110 120 130 140 ISO Horizontal Pressures on Windward Surfaces 12 13 15 18 21 24 Horizontal Pressures on Leeward Surfaces 9 10 13 14 15 18 Vertical Pressures on Screen Surfaces 3 4 4 5 6 7 Vertical Pressures on Solid Surfaces 10 11 13 15 17 20 AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2007 Edition) 1.0 Chapter 1 - Screen Enclosures Reitang(e , Hosr sTPLduRE (S:F.U.) -` (Beams fnust not be placed at outside cpomet of host eave, must align host structure]moll) ` °1 .Mainroof support -beams must be sudporto dlr&tly by host elements or carHer tiearia' oc ` Host Eave & Fascia - - - [Option6l] Carrier Beam ?y 1E H N ------------------- �' W, _ J--Pudins 1 a °° E O �7 W O w [SMEE N ENCLOSURE] - r 16 131y 90 Typical ilx rs a Typical 1. H : . , 1 1 z n. Rectangle i & Enclosure Length Overall [Overall length of the enclosure shall not be less than the projection] Typical Screen Enclosure Footprint (Size/Shape) Limitations [Schematic it General Limitations on Size and Shape (Footprint 1) Screen enclosures must be connected to a host structure (not free-standing) 2) Enclosure may be simple rectangular shape; OR, may consist of no more than 2 contiguous rectangular shapes 3) Included angles in corners must be perpendicular t 100 (800 to 100°); AND, main roof support beams must be perpendicular (within 100) to outboard (a.k.a. longitudinal) wall 4) Size of rectangles governed by member spans per tables except as noted In schematic diagrams 5) No maximum on length overall, minimum length must be greather than enclosure projection 6) Width and projection governed by beam span or 40 ft, whichever is less 7) Screen eave may not exceed 14 ft except for gable end of transverse gable or dome; sloping eave for transverse gable may not exceed 18 ft in height 8) Mean roof height in Exposure C may not exceed 15 ft 9) Typical bay module (typical spacing of posts, beams and purlins) may not be less than 5 ft nor more than 8 ft (refer to schematic elevations) General Notes and Limitations for Carrier Beams: 1) Carrier beams must be horizontal (flat) no other shape is permitted. 2) Maximum carrier beam span is a single span of 16 ft 3} Carrier beams may not conned to any Super Gutter comer, but must be connected aligned with the host support wall. Page 1 -1 AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2007 Edition) 1.0 N Chapter 1- Screen Enclosures MaArnum of 2 Bays (one beam only) or lb ft beyond host structurqwmhichlessC RE (S.F.D) MYplaced at outside., corner of host eave, must align with hostsirucjvre wall Main roo6'sup�ort heaths must be,.supported dir by host elements or canter beam a •; r Host Eave & Fascia 0 1 �[Optionhq Carrier Beam ; o ,y Purlins 1 I O , ; :,: ,.H [SCREE U• ENCLOSURE] c m c Typical 11"c"n-K!rS Typca. _ 1 fRectangle 1 & Enclosure Length Overall J [Overall length of the enclosure sha0 not be less than the projection] Typical Screen Encl rQ a Footprint (Size/Shape) Limitations fSchematic 21 Z. Z w N v c .-1 Maximum of 2 Bays (one beam only) or 16 ft, whichever is less. Rectangle 2 HOST STRUCTURE (S.F.D.) Main roof solport bearrtinust be supported directly by'hokelements of carrier."6eam. ' .\ / `i Host Pave &Fascia [OptioCarrier njQ Beam ' 'E r �Purlins s I i f4S' I 7 �Q r-1 L U' t Q _�J_______1_ ' 'IS{REEN I Q LU ENCLOSURE] . 90° fi10°) 90°'(t10°j i Q Typical a ;comers Typical ; a Rectangle 1 & Enclosure Length Dverall [Overall length of the endosure shall not be less than the projection] TVical Screen Enclosure Footprint Size/Shape) limitations jSchematic 31 AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2007 Edition)1.0 Chapter 1- Screen Enclosures BEAMS ZLIN �� ,cam ;• �. • •.,.� UJ � L7 z GIRT (AKA �c�y CHAIR RAIL)<..00 WALLS MAY BE BRACED BY EITHER Ile K-BRACING OR CABLES EAVE RAIL TYPICAL HIP ROOF ISOMETRIC FOR ALLOWABLE SPANS, REFER TO: TABLE 101 FOR BEAM SPANS TABLE 102 FOR POST SPANS TABLE 103 FOR PURLIN SPANS TABLE 104 FOR GIRT SPANS TABLE 109 FOR GABLE RIDGE SPECIFICATIONS BEAM SPACING BEAM SPAN PURLIN I EAVE LU LCOLUMNS K-BRACING (OPTIONAL) HIP ROOF SIDE ELEVATION HIP ROOF FRONT ELEVATION COLUMNS CABLE BRACING AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2007 Edition) 1.0 N 0 0 V rn Q. 0 m 0 REFER TO TABLE 109 AND BEAM SCREEN SAVE SPLICE DETAILS CONNECTION BEAM PURLIN FILMIEOGIUARi(opy mJJJN - ------ ---------^- r EAVE RAIL = SUPER GUTTER z SPAN OF SCREEN BEAM z z 5 ,. a a HOST EAVE �' /' •' ; INTERMEDIATE GIRT FOR ALLOWABLE SPANS, REFER T0: TABLE 101 FOR BEAM SPANS w GIRT (CHAIR RAIL) TABLE 102 FOR POST SPANS = TABLE 103 FOR PURLIN SPANS u.j TABLE 104 FOR GIRT SPANS ,' ,10 TABLE 109 FOR GABLE RIDGE SPLICE SPECIFICATIONS REFER TO SOLE CONNECTION DETAIL TYPICAL SECTION FOR GABLE & HIP fu 'R M N rn z rn c Chapter 1 - Screen Enclosures LAP BEAM (A.K.A SMB ESELF�MA'TI`NGGBBEAM ])� REFER TO EAVE DETAILS—-, i EAVE L—� i F BEAM FLANGE STITCH SCREWS AT 24" O.C. TOP AND BOTTOM#12 SINS FOR l 2XO AND 2XID, ALL OTHERS #10 SMS OPTIONAL OPEN VACK P SCREEN ROOF BEAMS f" (SCREEN ROOF SHAPD BEAM SLOPES VARY}ARY),, SELECT PER TABLE 101 BEAM FLANGE TRIMMED TO ACCOMODATE INSERTION OF a POST,LAP BEAM WEBS OVER P057 i AND FASTEN W14 EACH #12 SMSOR #14 SMS PER SIDE OF ` POSTIT(BEAM CHAIR RAIKL(GIRT) -- [2X3 HOLLOW SHOWN] USE TABLE ID4 TO SELECT EXPLODED SECTION J LAP BEAM r-r (A.K.A. SMB [SELF -MATING BEAM )) ' SELECT POST PER TABLE 103 CHAIR RAIL (GIRT) 12X3 HOLLOW SHOWN] USE TABLE 104 TO SELECT �1 SOLE PLATE (IX2 OB OR 1X3 OB) V FASTENS TO FOUNDATIONWITH 1/4"0 CONCRETE ANCHORS AT 24' O.C. (PROVIDE IVA"MINIMUM EMBEDMENT) SOLE PLATE W/ANGLE AND f CONCRETE EXPANSION ANCHOR / SUPPLEMENTAL ANGLES & CONCRETE FASTENERS I [REFER TO FOUNDATION CONNECTION DETAILS CI(a), CI or C21 COkG*7, f;OUNDAIION M (NONAL.4d SLAB — UNLESSNOUP,OiTHERWISE) [DETAIL -Ij TYPICAL [BEAM BEARING] WALL SECTION AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2007 Edition)1.0 Chapter I -Screen Enclosures FILE Minimum 5 ft Ma>amum 8 ft Minimu ft Ma um 8 ft Minimum 5 ft Maximum 8 ft Screen Roof + + Eave Rail a.k.a. Shoulder)/ Top of Wall E 3 e4:�- 3 x 8 8 0 o oo Girt / Chair Rail (Sendary Wall Membe� rs 0K� Sole Plate ScheemaUc Elevations for Screen Enclosures with no Intermediate Girt Screen Roof ' 7 E Xin El L; o P b Ij Schematic ElevAtions for Screen Enclosures with Intermediate Girt AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2007 Edition) 1.0 Page I - I4 Eave Rail (a.k.a. Sh der}� Tnp of Wall N ' � Intermediate Girt � (Secondary Wall Member} i Minimum 5 It Maximum B ft z z z E �i � a o 1 Girt 1 Chair Flail (secondary Wall Member) O Sole Plate 2" Chapter 1- Screen Enclosures ' {? REFER TO TABLE 102 FOR ALLOVABLE SPANS CONCRETE FASTENING PER CONNECTION / DETAILS Ci(a), Ci OR C2 4" NOMINAL PATIO SLAB W/ 6 X 6 X 10/10 W.W.M. OR SYNTHETIC FIBERS ON WELL COMPACTED SOIL, (CONCRETE TO BE 2,500 P.S.I. MINIMUM) GRADE TYPICAL MONOLITHIC FOOTING DETAIL F1 (SCREEN WALL ON 31/2" MONOLITHIC PATIO SLAB (ONLY) 1 [DETAIL F1 TYPICAL FOR SCREEN ENCLOSURES UNLESS ADDRESSING ANGLE OF REPOSE (EROSION)] 2" GRADE J REFER TO TABLE 102 FOR ALLOWABLE SPANS CONCRETE FASTENING PER CONNECTION DETAILS C1(a), C1 OR C2 4" NOMINAL PATIO SLAB W/ 6 X 6 X 10/10 W.W.M. OR SYNTHETIC FIBERS ON WELL COMPACTED SOIL. (CONCRETE STRENGTH TO BE MIN. OF 2,500 P.S.I.) 1 COIYrINU US REINFORCING 1 EA #5 BAR FOR VkWIDE, 2 EACH #5 FOR FOOTINGS WIDER FOOTING DETAIL FZ (PATIO SLAB W/ MONOLITHIC EDGE FOOTING) 1 AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2007 Edition) 1.0 Chapter 1 - Screen Enclosures Detail C1 Elevations show the foundation connections for various depth columns (posts/uprights). Columns (posts/uprights) must not ex ble in T 0 . AY �2" 4" B U POS j ---2X4 POST / COLUMN 1 T' 2" --272"XI/B" ANGLE 2" LONG j 4 EACH #14 SMS INTO POST WEB o o --2"X2"X1/8" ANGLE 2" LONG e o' 1X2 OB SOLE PLATE 4 EACH APPROVED MASONRY ANCHORS Y4" 0 X 2V2" EMBEDMENT (3/8" 0 ANCHORS MAY BE SUBSTITUTED) SECTION / SIDE ELEVATION / 2X4 POST �C1 (FOUNDATION CONNECTION FOR COLUMNS NOT SUPPORTING K-BRACING) APPROVED MASONRY ANCHORS BY 21/2" EMBEDMENT _ 2" X 2" X 1/8" ANGLES IX3 OB SOLE PLATE PLAN VIEW SECTION (WI 1X3 SOLE PLATE, l_ Li_"\ TYPICAL C1 POST/COLUMN AT FOUNDATION 1 /J COLUMN SELECTED FROM TABLE 102 MT I I I V11 WHEN IX3 OB SOLE PLATE IS SUBSTITUTED: N 11 USE Y' LONG ANGLE ON SOLD PLATE AND EDGE OF APPROVED MASONRY ANCHORS BY 21/2" EMBEDMENT 2" X 2" X 1/8" ANGLES 1X2 OB SOLE PLATE FACE OF SCREEN WALL z" s" z° LONG ANGLE ON FOUNDATION PLAN VIEW SECTION (W//_ 1X2 SOLE PLATE)� C1 �, 3"; 3" ` zxs SMB POST/ COLUMN TYPICAL C1 POST/COLUMN AT FOUNDATIONI\ 1 — r --2"X2"XI/8" ANGLE 2" LONG I I 4 EACH #14 SMS INTO POST WEB a o -2"X2"X1/8" ANGLE 3" LONG i y or L' 1X2 OB SOLE PLATE 2" 4 EACH APPROVED MASONRY ANCHORS 1/4" 0 X 21/2" EMBEDMENT (3/8" 0 ANCHORS MAY BE SUBSTITUTED) SECTION / SIDE ELEVATION / 2X5 POST��C1�� �- 2X7 SMB POST/ COLUMN 4 EACH #14 SMS INTO 7" POST WEB (EACH SIDE) (WHEN IX3 SOLE PLATE IS 4" UTILIZED, ADJUST ANGLE LENGTHS ACCORDINGLY) / -- — 2"X2"X1/8" ANGLE 2" LONG 2"X2"X1/8" ANGLE 4" LONG n o (FOUNDATION CONNECTION FOR COLUMNS t i , NOT SUPPORTING K BRACING) 11 C ,I' ; - _ • +-2X6 SMB Post / Column 6' 4 EACH #14 SMS INTO POST WEB 3" 3-3/4" —(EACH SIDE) (WHEN 1X3 SOLE C PLATE IS UTILIZED, ADJUST 4. ANGLE LENGTHS ACCORDINGLY) 1 2"X2"XI/8" Angle 2" Long 2"X2'%1/8" Angle 4" Long ti n�o 1X2 OB SOLE PLATE 4 EACH APPROVED MASONRY ANCHORS 1/4" 0 X 21/2" EMBEDMENT (3/8" 0 ANCHORS MAY BE SUBSTITUTED) SECTION / SIDE ELEVATION / 2X6 POST ra (FOUNDATION CONNECTION FOR COLUMNS 1 ) NOT SUPPORTING K BRACING) / '4 EACH APPRO .ED MASONRY ANCHORS '/4" 0 X 21/2" EMBEDMENT (3/8" 0 ANCHORS MAYBE SUBSTITUTED) SECTION / SIDE ELEVATION / 2X7 POST C1� (FOUNDATION CONNECTION FOR COLUMNS 1 % NOT SUPPORTING K BRACING) 2X7 SMB CONNECTION DETAIL C1 ALSO APPLIES TO LARGER COLUMNS (MAINTAIN REQUIRED COMPONENT SIZES AND FASTENER SPACINGS) 1) MAXIMUM POST HEIGHT (SPAN) 18' 0" 2) FOR DETAIL C1 AND C2, POST HEIGHT OR SPAN NOT LIMITED BY TABLE 105 FOR NOMINAL 4" PATIO SLAB, DO NOT EXCEED 23/4" DEPTH FOR CONCRETE ANCHORS, WHERE CONCRETE DEPTH EXCEEDS 31h" DEPTH, ANCHOR MAY BE EMBEDDED UP TO CONCRETE DEPTH DIVIDED BY 1.25 AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2007 Edition) 1.0 Chapter 1- Screen Enclosures 8 FACH #14 SMS INTO POST WEB POST / COLUMN COLUMN SELECTED EACH SIDE 3" FROM TABLE 102 3"X3'7C3/1W ANGLE ; ,%—T LONG _s / 11' 1 APPROVED —MASONRY ANCHORS R' BY 21h" EMBEDMENT E 4X2 OR 1X3 SOLE PLATE WALL FACE L ELEVATION C2 TYPICAL C2 PC 71COLUMN at FOUNDATION 1 MINIMUM COLUMN SIZE FOR DETAIL C2 (SUPPORT OFK-BRACING) 2X6 SMB ZQ 6" 3.11p 2X6 SMB POST / COLUMN 3'X3 W/16' ANGLE 3' LONG r 8 EACH V14 SMS INTO POST'WEB, a o 3'9C W/B" ANGLE 3' LONG o n 0 a' O O 4 APPROVED MASONRY ANCHORS 3/8" G X 2W EMBEDMENT SECTION / SIDE ELEVATION / 2X6 SMB POST (LOCATIONS SUPPORTING K BRACING) 1 V (IX2 oB SOLE PLATE MAY BE SUBSTITUTED AS INDICATED IN 7" PLAN VIEW SECTWN) 3- 4" 2X7 SMB POST / COLUMN 3"X3'X3/16' ANGLE 3" LONG 8 EACH #14 SMS INTO POST WEB 0 0 —3 53'X3/8' ANGLE 3I/i" LONG i0 a o 0 a a 1X3 08 SOLE PLATE 4 APPROVED MASONRY ANCHORS 3/8" 0 X 2V.- EMBEDMENT SECTION SIDE ELEVATION 2X7 SMB POST C2 (LOCATIONS SUPPORTING K-BRACING) 1 �n N 3/$" 0 APPROVED MASONRY ANCHORS A BY 2'h" EMBEDMENT 3"X3"X3/16" ANGLE 3" LONG B 50LE PLA FACE OF SCREEN WALL PLAN VIEW SEMON w 1X2 SOLE PLATE) TYPICAL C2 POST/COLUMN AT FOUNDATION MINIMUM COLUMN SIZE FOR DETAIL C2 1 (SUPPORT OF K BRACNG) 2X6 SMB 3- 2" p 2X8 SMB POST / COLUMN 3--a"X3/16" ANGLE 3" LONG BEACH #14 SMS INTO POST WEB YV"X3/8" ANGLES 4" LONG o (MINIMUM) O O p p , O O 1X3 OB SOLE PLATE 4 APPROVED MASONRY ANCHORS 3/8" 0 X 21h" EMBEDMENT SECTION .SIDE ELEVATION / 2X8 SMI3 POST (LOCATIONS SUPPORTING K BRACING) 1 2X8 SMB CONNECTION DETAIL C2 ALSO APPLIES to 2X9 and 2X10 (MAINTAIN REQUIRED COMPONENT SIZES AND FASTENER SPACINGS) 1) MAXIMUM POST HEIGHT (SPAN)18' 0" 2) FOR DETAIL C1 AND C2, POST HEIGHT OR SPAN NOT LIMITED BY TABLE 10S FOR NOMINAL 4' PATIO SLAB, DO NOT EXCEED 23fa" DEPTH FOR CONCRETE ANCHORS, WHERE CONCRETE DEPTH EXCEEDS 3ye DEPTH, ANCHOR MAY BE EMBEDDED UP TO CONCRETE DEPTH DIVIDED BY 1.25 Detail C2 Elevations show the foundation Connections for various depth columns (pasts/uprights). Columns (posts/uprights) must not exceed allowable spans in Table 102, Page 1- 21 1 AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2007 Edition) 1.0 Chapter 1 - Screen Enclosures 1. As _____ANCHOR ___ _ 3/8" 0 APPROVED MASONRY ANCHOR 21/z" EMBEDMENT _.._ 3' X 3" X Va" ANGLE j BY 3" LONG J 1X3 08 (OPTIONAL) _ 3' X 3" X Y4" ANGLE BY 3" LONG 3/8' 0 APPROVED MASONRY r 3 EACH r ANCHOR 2'/2" EMBEDMENT Ci4 SMS - -' - 2" LONG 3" X 3' X W "ANGLE_ 1X3 OB SOLE PLATE r BY 3' LONG - - - EDGE OF CONCRETE FOUNDATION — - 3" X 3" X 0.072" HOLLOW PLACEMENT IN ANGLE PU,N yIEW SECTION I EXTERIOR CORNER AT FOUNDAQM FOR SCREEN ENCM Rf ES IN WIND ZONE 120 MPH AND GRE P, FOR NOMINAL 4" PATIO SLAB, DO NOT EXCEED 23h" DEPTH FOR CONCRETE ANCHORS, WHERE CONCRETE DEPTH EXCEEDS 3V+.° DEPTH, ANCHOR MAY BE EMBEDDED UP TO CONCRETE DEPTH DIVIDED BY 1.25 I.% v #10SMSBYIV2' f�1 16" D.C. 3" X 3" X 0.072" (MiI"UM) HOLLOW-- - --- 1X3 OMB 3" X i' X 0,072" SQUARE EXTRUSION (MAY OR MAY NOT HAVE SNAP FEATURES SHOWN _ 3' X 3" X IA" ANGLE SCR EW REW SLOT ARRANGEMENTS VARY) f^ BY 3" LONG I r - 3 EACH 014 SMS 2" LONG 3/8" 0 APPROVED MASONRY f ANCHOR 2Yz" EMBEDMENT - 1X8 OB SOLE PLATE • i r 3/8" 0 APPROVED MASONRY ANCHOR = -. THRU EXTRUDED POST BASE 2-318' LONG. 21A' EMBEDMENT PAMAL EL V, DON I EXTE,QI, R ORNER AT FOUNDATION FOR SCRM E,K1 OSURM_IM DZQK12Q-MPJ AND GREATER Page 1 - 23 1 AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2007 Edition) 1.0 Chapter 1 - Screen Enclosures 1"X2" OR1"X3"OB@ PERIMETER FASTEN PER NOTE #1 HOLLOW HORIZONTAL (GIRT) NOTE #1: USE 1/a"0 X 3" LONG LAGS INTO WOOD HOST AND 1/4V X 21/4" LONG CONCRETE SCREWS INTO CONCRETE OR MASONRY CONSTRUCTION (1" EMBEDMENT TYPICAL)/ SPACING 24" O.C. AND WITHIN fi" OF EACH PERPENDICULAR MEMBER 2- # 10 S.M.S. FROM INSIDE FACE OF 1 X 2 OB INTO SCREW SPLINES OF HOLLOW GIRT (1" EMBEDMENT MINIMUM.) CONNECTION W/ CONCEALED FASTENERS RTIAL ELEVATIONS / 2" X 2" GIRT TO 1" X 2" CON 4 - # 10 S.M.S. FROM INSIDE FACE OF POST INTO SCREW SPLINES OF HOLLOW GIRT (1-1/2" EMBEDMENT MINIMUM) -- GIRT OR CHAIR RAIL SELF MATING POST 4 3 f 'f CONNECTION W/ CONCEALED FASTENERS PARTIAL ELEVATIONS / GIRT TO POST CONNEC AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2007 Edition) 1.0' C4 ' 1 Chapter 1 - Screen Enclosures CONNECTION WITH EXPOSED FASTENERS I- X 2- OB @ PERIMETER REFER TO NOTE *I - THIS SHEET 2- it 10 S.M.S. FROM INSIDE FACE OF —PERIMETER EXTENSION INTO SCREW SLOTS OF PERIMETER (1-1/2' EMBEDMENT MINIMUM) REFER TO NOTE #1 - THIS SHEET NOTE #I.- USE 1/4"0 X 3" LONG LAGS INTO WOOD HOST AND 1/4"0 X 21/4" LONG CONCRETE SCREWS OST 5T91J&URt ELWENTS, INTO CONCRETE OR MASONRY CONSTRUCTION (I" EMBEDMENT TYPICAL)/ SPACING 24" O.C. AND WITHIN 6" OF EACH PERPENDICULAR MEMBER CONNECTION WITH CONCEALED FASTENERS PARTIAL ELEVATIONS / PERIMETER EXTENSION CONNECTIONS FIL%tw: COPY' 6" LONG GUTTER BRACKET 3 EACH #12 SMS----- 1112 011 2" X 2" X I.X ANGLE EACH SIDE ] OF BEAM (MINIMUM 2- LONG) WITH 2 EACH #14 SMS INTO BEAM WEB 7 ROOF BEAM /'(PER TABLE 101) BEAM MAY BE SLOPING OR HORIZONTAL: wl 10* EXTRUDED GUTTER BRACKET BY 6" LONG AT EACH BEAM WITH 3 EACH 318" 0 LAG SCREWS INTO FASCIA (ALSO PROVIDE LAG SCREWS BETWEEN BEAMS ALONG GUTTER AT 24- O.C.) 118" ANGLE CONTINUOUS SHIM (CUT TO ACCOMODATE SLOPE) 2" X 2- X 1/8" ANGLE EACH SIDE OF BEAM (MINIMUM 2" LONG) WITH 2 EACH #14 SMS INTO BEAM WEB AND INTO SUPER GUTTER CHANNEL.COVERING OPEN BEAM (INCIDENTAL TO DESIGN) BEAM MAY BE TRIMMED ALTERNATE SUPER GUTTER CONNECTION DETAIL (2) BEAM TO HOST EAVE AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2007 Edition) 1.0 Chapter 1 - Screen Enclosures WHERE ?I jRUNS ARE ADJACENT TO DIAGONAL ROOF BRACING, BRACING CONNECTIONS REQUIRE BACIUNG PLATES, EXTEND DIAGONAL BRACING SACKING PLATES AND UTILIZE FOR PURUN CONNECTION 2'h' X 3h' X It8" BACKING PLATE (REQUIRED IN WIND ZONES 120 MPH AND ABOVE) SELF -MATING OR LAP EXTRUSION (SCREW BLOTS) -� 2'X2'XI1W ANGLE EACH SIDE 4 EACH #14 SMS INTO PURUN WEB AND 4 t EACH INTO BEAM WEB (ANGLE EXTENDS TO WITHIN W" OF TOP AND BOTTOM OF CONNECTING PURUN AND FASTENERS SPACED EVENLY) 4 °I 10 HOLLOW PURUN (SELECT PER TABLE 103) MAY BE SLOPING OR HORIZONTAL WITH 11h' LONG #10 SMS FROM INSIDE BEAM INTO PURUN SCREW SLOTS IIV BACKING,PLATES AND 6 #10 SMS INTO HOLLOW PURLINS REQUIRED IN 120 MPH ZONES AND GREATER, IN WIND ZONES UP TO 119 MPH, USE 4 #10 SMS INTO PURUNS SON J ANGLEXHANNEL OR _ 39 .INTERNAL FASTENING AT SLOPING PURUNS , WHERE PURU.INS ARE ADJACENT TO DIAGONAL ROOF 29t' X 3W" X 1(8" BACKING PLATE BRACING, BRACING CONNECTIONS REQUIRE BACKING (REQUIRED IN WIND ZONES 120 MPH AND ABOVE) PLATES, EXTEND DIAGONAL BRACING BACKING PLATES 1 AND UTILIZE FOR PURUN CONNECTION 0 2"X7X11a" ANGLE EACH SIDE 3 EACH #14 SMS INTO PURLIN WEB—/% � HOLLOW PURLIN (SELECT PER TABLE 103) AND 4 EACH INTO BEAM WEB ( 118" THICKNESS RECEIVING MAY BE SLOPING OR HORIZONTAL WITH I IW' LONG 010 SMS FROM INSIDE CHANNEL MAY ALSO BE USED BEAM INTO PURUN K IN SCREW SLOTS FASTENED AS SHOWN) 1ff BA"G PLATES AND 6 S30 SMS INTO HOLLOW PURUPS REQUIRED IN 120 MPH ZONES AND GREATER, IN WIND ZONES UP TO 119 MPH, USE 4 #10 SMS INTO PURUN$ ROOF BEAM PURUN TO BEAM CO NEMON ' . AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2007 Edition) 1.0 Chapter 1- Screen Enclosures END BAY (-IiW') PURUN (SL.QEE VA r X 3" X 0.072" EAVE RAIL (MAY OR MAY NOT HAVE SNAP FEATURES SHOWN AND SCREW SLAT -.. ARRANGEMENTS VARY) EAVE RAIL CONNECTS TO BEAMS VIA INTERNAL #10 SMS X 1'1a' LONG OPTIONAL IX3 OPEN BACK EXTRUSION ON BOTTOM OF EAVE RAIL, FASTEN TO POST LVj 2 EACI #10 SMS X 11hw LONG INTO SCREW SLOTS OF 1K3 AND CONNECT TO SAVE RAIL W/ #10 X Ile AT 24" O.C. SCREWS CONNECTING OPEN BACK TO EAVE MAY BE OMMITTED WHEN CONTINUOUS SNAP SECTIONS ARE UTILIZED 3" X r X 0.472" EAVE RAIL (MAY OR Wi NOT HAVE SNAP FEATURES SHOWN AND SCREW SLOT ARRANGEMENTS VARY) SAVE RAIL CONNECTS TO BEAMS VIA INTERNAL *10SMS X LV2" LONG POST FLANGE TRIMMED TO LAP WEBS OVER PURLIN AND FASTENED WITH 5 EACH *14 SMS EACH SIDE SIDE WALL POSTICOLUMN SECTION (1) AT SCREEN EAVE ON SIDE WALLS (FOR WIND ZONES 120 MPH AND GREATER) r r \ _ T BEAM FLANGE STITCH SCREWS AT ' 24" O.C. TOP AND BOTTOM #12 SMS FOR 2X9 AND 2X10, ALL OTHERS #10 SMS OPTIONAL DO OPEN BACK EXTRUSION ON 0 �9 BOTTOM OF EAVE RAIL, FASTEN TO ' BEAM (MAY BE HORIZONTAL OR POST Wf 2 EACH #10 SMS X 1V12' LONG I 0 C �, SLOPING), SELECT FROM TABLE 101 INTO SCREW SLOTS OF W AND CONNECT ` EAVE RAIL MAT 24"O.C. 4 EACH *L4 SMS PER SIDE WEB TO WEB SCREWS CONNECTING OPEN BACK TO SAVE (MUJIMUM) MAY BE OMMITTED WHEN CONTINUOUS TRIM BEAM FLANGE TO ACCOMODATE POST SNAP SECTIONS ARE UTILIZED i AND LAP BEAM WEBS OVER POST WEBS SECTION (2) AT SCREEN EAVE ON LONGITUDINAL WALLS (FOR WIND ZQNE 12Q MPH AND GREATER AIL AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2007 Edition) 1.0 CibpterI _ Screen Enclosures Miter splices shown for mansard splices, identical Splice Plate Alloy: specifications for gable and/or straight beam splices. 6061T6 or 5052H32 _ 2 SCREWS ALONG CENMRLINE Maximum angle for mansards 390 _ OF PLATE EVENLY SPACED Maximum angle for gables 450 INTERNAL SPLICE PLA k + Q R / O +-{---------------------------- ki I #14 SMS Typical• ° / �vo o���y0g / pI: Screw positions near miser joint may be adjusted to aanmodate puriin, space between fasteners along miter joint may isle to 2", maintain maximum and minimum distances between screws. r Edge Distance for Screws: 3/4" Minimum Screw spacing: 5/8" SPLICE SPECIFICATIONS PER TABLE 109 BELOW TYPICAL ELMTIQN FOR BEAM MITER 21KE [DErAIL MAY BE ROTATED FOR GABLE RIDGE SPLICE, AND MAY ALSO SERVE AS SPECIFICATIONS FOR A STRAIGHT SPLICE, MAINTAIN PLATE AND CONNECTOR SPECIFICATIONS IN TABLE 109 FOR ALL] Beam Splice Details Table 109 Beam 2X6X0.050X0.120 SMS 1 Splice Plate Dimensions ! Thidmess length 1 Height 1/8" 16" S1/4° #14 SMS Per Side Per End 14 Total #14 SMS Per Splice 56 Fastener Spaces Number of Spaces Horizontal 3 Vertical 3 2X7X0.055X0.120 SMB 1/8" 16" 61/4" 14 56 3 3 2XSX0.072X0.224 SMS 3/16" 18" 71/4" 16 64 4 3 2X9X0.082X0.306 SMS 3/16" 18" 8'/4" 18 72 4 4 2X10X0.092X0.389 SMS 1/4" 20" 9" 22 88 4 6 AAF GUIDE TO. ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2007 Edition) 1.0 I ^ ` I Purlins I I u j El \\�� IE I E I E EI En m1 z� Im Im Im ml i I Purlins I I SIDE WALL K-BRACING Z OPTIONAL WHEN SIDE WALL 1 I I IS FEWER THAN 3 BAYS I I I i CO Purlins I I I i I I I i i Screen Wall K Braces Screen Enclosure Roof Bracing Strategies - Schematic #3 Proje K Brace o i ! H RU (S. ) --` -#-- r I a, a� [NLL BRA(xjVG ENV 2MBAFY y 1O m u CL I i I I I I ' .` Roof:Diagonal j 2T �� ----F. `'i---- j — ----I Purlins ' _1 5:7 co it '^ I I I I I I E I 1tV I E E I I E c} 11J 00 Z Im I Ca I ,'z Im w N I I I I I I ---- --- £ o [2ndBayj I I Roof Diagonal I I g .co I I m I I ,' I PurlinsLL .n K-Braces Dimension (Length of Enclosure & partial lateral exposure) Screen Enclosure Roof Bracing Strategies - Schematic #4 AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2007 Edition) 1.0 Chapter 1 - Screen Enclosures HO S U R I ! I ! I ! I I ! I I I I I ! I I I I I I 1 I I [kREEN ENi LOSURE� I ! I ! I F- I [Diagonal Roof Bracing Not Required] I I I I I I I I I I I I ! I ! I I I I 1 I I I I I Screen Wall Screen Enclosure Roof Bracing Strategies - Schematic #1 HO U R , - -.... - - i -- �I in E v I d in I I col I EI I — �e 3 I I I afOil ml >. I 16 r- E Purlins I I I SIDE WALL K BRACING v ! I I I I OPTIONAL WHEN a u I I I I 1 SIDE WALL IS I I ! I 1 LESS THAN 3 BAYS Screen Wall K Braces K Braces Longitudinal Dimension (Length of Enclosure) Screen Enclosure Roof Bracing Strategies - Schematic #2 ROOF BRACING NOTES: 1) BRACE FULLY 2nd BAY FROM EACH END BETWEEN BEAMS, ONLY CORNERS IN Ist_BAY 2) ORIENT BRACES TOWARD CENTER OF ENCLOSURE AS SHOWN AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2007 Edition) 1.0 Page 1 - 38 I I ADD 2 ADDRIONAL FLANGE STITCH SCREWS WHEN INTERNAL BACKING —ZX3 (0.050" 0110.07Z") HOLLOW PLATE IS UTILIZED\ PURl1N \ 2X2X1l8 CHANNEL STRAIGHT OR ANGLE CUT (� , ROOF BRACING CONNECTIONS MAY ALSO 4 EACH #14SMS THRU CHANNEL INTO BEAM - - - A SE UTILIZED FOR K-BRACING (WALL BRACING) 4 EACH SIDE #14 SMS THRU CHANNEL _ ax WHEN WALL BRACING CAN BE 2X3, USE INTO HOLLOW TUBE DIAGONAL CONNECTIONS APPROPRIATE TO MATCH ................ . ...... ... ......................... _ . _ :.. . THE ORIENTATION OF THE BRACE. 3")a XO.090" HOLLOW TUBE DIAGONAL 1.71"IF C7 BEAMS MAY BE SLOPING OR HORIZONTAL :..................... .. " HOLLOW TUBE DIAGONAL ROOF BEA 0 y- -- ROOF BEAM Elevation View Sedan SCREEN ROOF DIAGONAL BRACING SCHEMATIC (#2� K-BRACING NOTE: THESE CONNECTION DETAILS MAY BE UTILUM FOR K BRACING n U IT Chapter 1 - Screen Enclosures SCREEN ROOF K BRACE MEMBERLEGM TABLE 105 KEY EXTRUSION A 2X2XO.046 Hof S 2X3X0.050 C 2XV0.090 D 2x3X.072 E 3X3X0.072 F 3X3X0.090 - ________,_Ewe HeigMfor Enclosure ------ ---------------- .......---' -- I ' Beam / Post Spadng IVR M R I ' I 1 1 1 W 1 I I------------- --• W Bin / Post Spacing Beam /Post Spacing I �1 I 2: I I ' �I 1 OI 0. 11CCL' .. _..._-.k-___-_. .... .....-..-.__••___•----------------• .. .. __-_`------- ------- N K BRACING IN END (FIRST] B Y (MINIMUM] LENGTH OF K BRACING AREA Schematic Partial Elevation for Screen Enclosure MI M NI LBVFH OF K BRACIM AREA FOR ONE EN! OF LOPM DD AL WALL TABLE 107 MAXIMUM TOTAL HEIGHT OF ENCLOSURE BY WIND ZONE Enclosure Pro'ecdon 110 120 130 140 12 15 18 12 15 1 18 12 1 15 1 18 12 1 15 18 20 5 5 6 5 5 6 5 5 7 5 6 8 25 5 5 6 5 5 7 5 5 8 5 6 10 30 5 6 7 1 5 6 B 5 6 10 5 7 12 35 5 6 1 8 5 7 10 5 7 11 5 8 13 40 K BRACING REQUIREMENTS ON LONGITUDINAL WALLM: 1) EQUAL K-BRACING SMALL BE PROVIDED AT BOTH ENDS OF THE LONGITUDINAL WALL UNLESS BRACED BY HOST STRUCTURE AS PROVIDED IN SCHEMATICS; 2) LOOKUP ENCLOSURE HEIGHT, ENCLOSURE PROJECTION AND LONGITUDINAL PANEL WIDTH IN TABLE 108 TO FIND DIAGONAL EXTRUSTION TYPE AND END FASTENING (EXTRUSION KEY TABLE 106) ALL SCREWS #14 SMS EACH SIDE EACH END; 3) TABLE 107 INDICATES MINIMUM LENGTH OF K-BRACING AREA FOR ONE END 4) TABLE 107 DOES NOT DICTATE POST SPACING, I.E. LENGTH OF K-BRACING PROVIDED BY DESIGN MAY EXCEED TABULAR VALUE BUT MAY NOT BE LESS THAN TABULAR VALUE; 5) ORDER OF PROFILES IN TABLE 108 INDICATE RELATIVE STRENGTH FROM WEAKEST (A)TO STRONGEST (F), A STRONGER MEMBER THAN REQUIRED MAY BE SUBSTITUTED; 6) INTEGER AFTER SLANT SIGN IN TABLE 108 INDICATES NUMBER OF #14 SMS PER SIDE PER END OF DIAGONAL 7) LONGITUDINAL GABLE ENDS REQUIRE ADDITIONAL BRACING, A MINIMUM OF 2 BAYS EACH AND BAY NEARER CENTER (HIGHEST) MUST BE BRACED TO TOP OF COLUMN (REFER OR ISOMETRIC SCHEMATICS AT BEGINNING OF CHAPTER). K BRACING REQUIREMENTS FOR SIDE WALLS _ 1) WHEN SIDE WALL IS_3 BAYS.PROVIDE K-BRACING IN GQRNER_(l5t)-BAY --- - _ -_ - - - - 2) FOR 1 OR. 2 BAY SIDE WALLS, K BRACING OPTIONAL 3) FOR SIDE WALLS OF 4 BAYS OR MORE, PROVIDE ONE BAY K BRAC NG IN 2nd BAY AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2007 Edition)1.0 Y 2" X 2' X 1/8" ANGLE EACH SIDE OF BEAM - (TYPICAL) APPENDIX D Chapter I Span Tables for Alloys 6061T6 OR 6005T5 1 x 2 O.B� 1. 1/4 0 X 3 LONG LAG SCREWS FOR LUMBER HOST - 3/8" 0 X 3" LONG MASONRY SCREWS FOR MASONRY HOST STRUCTURES PER TABLE 114 T' 0 3+ 2" X 2" X 118" ANGLES LENGTH FULL DEPTH OF BEAMS EACH SIDE EACH END W/ FASTENING PER TABLE 108 HOST STRUCTURE (MASONRY OR 1/4" 0 X 3" LONG LAG SCREWS FOR LUMBER HOST - 3/8" 0 X 3" LONG MASONRY / rSCREWS FOR MASONRY HOST "�`STR SIZE PER LUMBER FRAME) UCRIRES PER TABLE 114 101 OR 110 —N BEAM TO [HOST] WALL CONNECTION 1/4'' N G S�CfiEWS FQg LUMBER FILEH O 3/8° LONG MASONI. �Y SCREWS FOR ONRY 5T CiFJIt �� HOST STRUCTURE (MASONRY OR PLAN LUMBER FRAME) I ALLOWABLE SPANS for Primary Members In Screen Walls (Posts/Columns) Table 102 e Wind Zane = 140 MPH Appled Unt Load = 21.0 PSF Exposure B Post } Coiumn Load Widths or Spacing 4'-0" 4'-6" 5'4" T-6" 6-0" 6-6" `-a" T-6" 8'-0" 2" X 2" X 0. 46" X 0.046" Hobw 4'-11" 4'-8" 4'-5" 4'-1" 41-0" T-10" 3 3'-7" 3'-6" 2" X 3" X 0.05" X 0.05" Holow T-2" 6'-9" 6'-5" 6'-2" 5'-10" T-8" 5'-5" 5'-3" 5'-1" 2" X 3" X 0,05" X 0,05" Snap 741 7'-3" C-11" 6'7711 61-4" 1 6'-1" 5'-10" 51-8" 5'-5" 2" X 4" X 0.050" X 0.050" Hobw 8W, T-10" 7-5" 7-1" 6'-10" 6'-6" 6'4" 6'-1" 1 5'-1 i " 2" X 4" X 0.05" X 0.05" Snap 9` 3" 8'-8j1 8'-3" 7-10" 7-6" T-3" 6'-11" 6'-9" 6'-6" 2" X 5" X 0.050" X 0.050" Hobw 8'--T1 8'-11, 7-8" T-4" 7-0" 6-911 611-6" 6'-311 6'-l" 2"X4"X0.046"X0.10" SMB 7-11" T-5" T-1" 6'-91, 6'-51, 6'-2" 5'-11" 5'-9" 5'-7" 2"X5"X0.05'X0.1167' SMB 91-911 9'-2" 81-9" 81-4" T-11" T-8„ T4" T-1" 6'-11" 2"X611x0.05"X0.12" SMB 10'-6" 9'-10" 9'-4" 8'-11" 81-611 8'-2" 7'-11" T-8" 7'-5" 211x7"x0.05s1Ix0.12" SMB 11'-B" 10'-111, 101-5" 9' 11" 91-6" 9'-1" 8'-91` 8'-6" V-3" 2"X8X.072"X0,224r1 SMB 21'-9" 20'-6" 191-5" 19-6" 17'-9" 17'-l" 16'-5 15'-11" 15'-4" 2"X9"X.082"X.306" SMB 29'-7" 27'-11" 26-6" 25'-3" 241-2" 23'-3" 22 !P' 21'-7" 20'-11" 2"X10"X.092"X.389" SM(3 I 3.1'-11" 32'-11" 31'-3" 29'-10" 1 28'-6" 27'-5" 2G'-a^' 25'-G" 24'-8 u FOR IL40 mph Wind Zone 1 1-4, 1 -,A - 'II Table 104e Loa d S cin Extrusion W-0" 4'-6" 5'-0" 5'-6" 6-0" 6'-61 7-0" 2X2X.046 Hollow 47-11" 4710 4'-9" T-8" 4'-8" 4'-e, 4-81, 2X3X.650 Hollow 7'-5" 7'-3' 7'-l" 6-11" 6'-11" 6-11" 6-11" 2X4X.05" 7' SO" 7'-10" T-10" T-10" 7-10" T-10"' T-10" 2X3X.072" T-10" T-10" 7'-10" T-10" 7'-10" T-10" Maximum Spacing (Vertical) 7 ft o.c.; maximum allowable span 7' 10") NOTE (Table 104): maximum span of 7 10" governed by maximum post spacing of 8' 0" AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2007 Edition) 1.1 1 Page D - 26 I` Chapter 1- Screen Enclosures -Addendum 1.2- (May 2009) Alloy: 6005-T5 - Screen Mesh: 18/14 - Exposure B Allowable Spans for Gabled Beans with a Rise of 5 ft (Maximum) Table 101(e)8 18/14 Screen Mesh (Only) Wall Height 8 ft Roof Design Pressure: 5.3 (psf) Exposure B Wind Zone: 140 mph Wall Design Pressure: 18.5 (Dsf) 6005T5 Alloy Beam Spacing in Feet Self -Mating or Lap Beams 5' 0" 5' 6" 60" 6' 6" 79, 7' 6" 8-9- 2 X 6 X 0.050 X 0.120 SMB NA NA NA NA NA NA NA 2 X 7 X 0.055 X 0.120 SMB NA NA NA NA NA NA NA 2 X 8 X 0.072 X 0.224 SMB 21'-9" 18'-3" 14'-10" 11'-3" 6-11" NA NA 2 X 9 X 0.082 X 0.306 SMB 39-9" 36-11" 34'-5" 32'-1" 29'-&' 27'-4" 2 X 10 X 0.092 X 0.374 SMB 50`-2" 47-1" 44'-4" 44'-Z' 39','.1! - 3T-6" 35-7" Allowable Spans for Gabled Beams with a Rim of 5 ft (M xkwm)Y Table 101(e)11 18/14 Screen Mesh (Only) Wall Height 11 ft Roof Design Pressure: 5.3 (psf) Exposure B Wind Zane: 140 mph ,, Wall benign Pressure: 18.5 (Dsf) 6005T5 Alloy BeamSpacing in Feet Self -Mating (or Lap) Beams 5' 0" 5, 6, 60" 66, T 0" 7' Ut 8' 0" 2 X 7 X 0.055 X 0.120 SMB NA" - NA NA NA NA NA . 2 X 8 X 0.072 X 0.224 SMB : 6'-10' , . 1Z'-3" ' 6'-6" NA NA NA NA 2 X 9 X 0.082 X 0.306 SMB 3 -4" 34'-5" 31'41 28'-10" 26-1" 23'-6" 20'-11" 2 X 10 X 0.092 X 0374 SMB 477-1 P, : 44-1(y, 42'4' 41'-10" 37-1" j 341-11" 1 V-7' Allowable Spans for Qabled Beans with a Rise of 5 ft (Maximum) Table 101(e)14" . 18/14 Screen Mesh (Only) Wall Height: 14 ft Roof Design Pressure: 5.3 (psf) Exposure B _ Wind Zone: 140 mph Wall Desicin Pressure: 18.5 (Dsf) 6005T5 Alloy Beam Spacing in Feet Self -Mating or La Beams 5191 56, 61011 6161 7 0" 7' 67 8' 0" 2 X 8 X 0.072 X 0.224 SMB 10'-2" NA NA NA NA NA NA 2 X 9 X 0.082 X 0.306 SMB 34'-11" 317-10" 28'-6" 25-3" 22'-2" 19'-2" 16-1" 2 X 10 X 0.092 X 0.374 SMB 45'-10" 1 42'-8" 39'-9" 1 39-7" 34'-7" 31'-10" Addendum Page# 74 Page 1- 69 I AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2007 Edition) 1.2 APPENDIX D Chapter 1 Span Tables for Alloys 6061T6 OR 6005T5 ALLOWABLE SPANS for Purli►s Exposure B 600M Alloy Table 103 Sloping Purlins(Rise = 4 ft) FOR 14U mph Wind Zone Table Me Maxim, im Snwnrn R ft Cimino liurlinc 12ira = h ft\ Wall Haie,ht = A ft Load Width J S ci C>&uslon (Purlln) 51-0" le -G" Go" G'.G" 7 0" T G" 0' 0" 2 X 4 X 0.046 X 0.100 SMB 5'-5" 5'.2" 4'-10" 4'-5" NA NA NA 2 X 4 X 0.050 X 0.050 Hollow 5-9" 5'-4" 4'-11" 4'-7" 4'-1" 3'-8" T-2" 2 X 3 X 0.072 X 0.072 Hallow 6'-7" 6'-2" 5'-10" 5'-5" 4'-11" 4'-7" 4'-2" 2 X S X 0.050 X 0.116 SMB 8'-0" 814Y" T-0" 6'-8" 6-4" 5'-11" 2 X 5 X 0.050 X 0.050 Hollow 8'-0" 6'-10" 6'-6" 6-1" 5'-9" 5-4" NA 2 X 6 X 0.050 X 0.120 SMB 8'-9, 8'-0" 8'-0" 8'-0" 7 4' 7-0" 6'-8" 2 X 7 X 0.055 X 0.120 SMB 8'-0" 8,-0" 81_0" 8'-0" a'-0" 0-0" 7'-9" FOR 140 nVh Wind Zone Table 103e MAvimllm Snarirn R ft Sbpina Purlins (Rise = 4 fit)Wall Fbinht = 11 ft Load Width I S Dacinq Extrusion (Perlin) 5'-01, 5' b° 6'-0" 6-6" T 0" 7-6" 1 8'4" 2 X 4 X 0.046 X 0.100 SMB 4'-11" 4'-7" NA NA NA NA NA 2 X 4 X 0.050 X 0.050 Hollow 5'-Z" V-8" 4'-2" 3'-7" 3'-0" Z-3" 1'-4" 2 X 3 X 0.072 X 0.072 Hollow 6'-0" 51-7" 5'-1" 4'-7" 4'-0" 3'-5" 2'.10" 2 X 5 X 0.050 X 0.116 SMB 8'-0" 6-10" 6'-6" 6-1" 5'-8" 5'-3" 4'-10" 2 X 5 X 0.050 X 0.050 Hollow 614, 6-3" 5'-10" 5'-5" NA NA NA 2 X 6 X 0.050 X 0.120 SMB V-0" 81-0" 8'-0" 7'-2" 6'-9" 6'-4" 5'-11" 2 X 7 X 0.055 X 0.120 SMB 8'-0 8'-0" S'-o" 8'-U' 8'-0" Ts'- 6'-11" FOR 140 mph Wind Zone Table 103e Maximum Snarirn R ft Sloping Purim (KiSe = 4 ft) Wall Heiaht = 14 ft Load Width I Spacing Extrusion (Perlin) 5'-0" 5'-6" 6-0" 6-6" 7'-0" 7'-6" 8'-0" 2 X 4 X 0.046 X 0.100 SMB NA NA NA NA NA NA NA 2 X 4 X 0.050 X 0.050 Hollow 4'-6" 3'-l0" 3'-2" 2'-4" 1'-0" NA NA 2 X 3 X 0.072 X 0.072 Follow 5'-5" 4'-10" 4'-3" T-7" 2'-9" 1'-9" NA 2 X 5 X 0.050 X 0.116 SMB 6'-10" 64' 5'-11" 5'-5" 4'-11" 4'-6" NA 2 X 5 X 0.050 X 0.050 Hollow 6-2" 5'-8" NA NA NA NA NA 2 X 6 X 0.050 X 0.120 SMB 6' 0" 8' V. 7' 0" 6' 6" 6' 0" S' 6" 5' D" 2 X.7 X 0.055 X 0.120 SMB 8'-0" 8'-0" 8'-0" 8'-0" 7'-2" 6'-8" 6'-2" AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2007 Edition) 1.1 1 Page D - 36 J ALLOWABLE SPANS for Purim Chapter 1- Screen Enclosures FIAT(HORII(NTAL) PMLE S FOR ALL W= ZONES I FLAT (horizontao PlRLDS Spans Limited by 300# Live Load for: 2X2 X .046" Hollow: Maximum Span = 3' 8" 2X3 X .050" Hallow: Maximum Span = 6' 3" 2X4 X .046" X 0.10" SMB: MaArnum Span = G 7" Odwwise, extrusions listed below, maximum span equal to or greater than 8' 0" for spacings from 5' 0" to 8' V1 2 X 4 X 0.050 X 0.050 Hollow 2 X 3 X 0.072 X 0.072 Hollow 2 X 5 X 0.050 X 0.116 SMB 2 X 6 X 0.050 X 0.120 SMB 2 X 7 X 0.055 X 0.120 SMB 3 X 3 X 0.072 X 0.072 Hollow ALLOWARM BEAM SPANS (FT) FOR REWN FUOR7" TABLE 111 FYPngl PF R Ff]n]TTw., Si7FS ann rRncc-crrTTnn)ai nocne WIND ZONES . 81 9"X9" 108 9" X 12" 144 12" X 12" 192 16" X 12" 256 16" X 16" 24.3 32.3 43.1 57.5 76.6 130 19.4 2-5.9 34.5 46.0 61.3 140 16.2 21.6 28.7 38.3 _ 51.1 TABLE NOTES:, 1) MAXIMUM SPAN 40 FT, WHERE TABULAR VALUES EXCEEDS 40 FT USE 40 FT 2) HEIGHT, AND WIDTH DIMENSIONS MAY BE REVERSED 3) TABLE MAY BE INTERPOLATED BY CROSS -SECTIONAL AREA Table 103 FASTENER SPEGIFlCAMM FOR ENDS OF ROOF SUPPORT BEAMS IN SCREEN ENO-OSURES CONrECTJON BFAM TO BEAM OR TO HOSTSIBUCRRE Terms isa BY BEAM AND FASTENER Beam Fasteners into Beam to Host Structure #12 SMS # Each per Side #14 SMS # Each per Side 3/8" Thru Bolts 1/4" Dia Lag Screw (per side) 3/8" Fla Masonry (per side) 2 X 4 X 0.045 X 0. 100 SMB 3 3 2 2 2 2 X 5 X 0.050 X 0. 100 SMB 4 3 2 3 2 2X6X0.050X0.120SMB 4 3 2 3 2 2 X 7 X 0.055 X 0. 120 SMB 4 3 2 3 2 2 X 8 X 0.072 X 0.224 SMB _ 4 _ 3 2 4 _ _ 3 _ 2 X 9 X 0.082 X 0.306 SMB 4 4 3 5 1 3 2 X 10 X 0.092 X 0.374 SMB 5 4 3 S 1 4 Page 1- 87 1 AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2007 Edition) 1.0 LEA A t = DELTA ANGLE L = ARC LENGTH CATV = CABLE TV C.B. = CATCH BASIN C.B.S. = CONCRETE BLOCK & STUCCO (L = CENTERLINE CONC. = CONCRETE COV. = COVERED D.E. = DRAINAGE EASEMENT ELEV. = ELEVATION E.O.P. = EDGE OF PAVEMENT E.O.W. = EDGE OF WATER F.F. = FINISHED FLOOR FND. = FOUND F.P.E. = FLOOD PLAIN EASEMENT F.P.L. = FLORIDA POWER & LIGHT L.M.E. = LAKE MAINTENANCE EASEMENT L.S.S. = LANDSCAPE AND SIGNAGE EASEMENT M.H. MANHOLE MON. = MONUMENT N.G.V.D. = NATIONAL GEODETIC VERTICAL DATUM N.R. = NOT RADIAL O.E. = OVERHANG EASEMENT O.M.E. = OVERHANG MAINTENANCE EASEMENT O.R.B. = OFFICIAL RECORD BOOK O/S = OFFSET O.S. = OPEN SPACE TRACT P.B. = PLAT BOOK P.C. = POINT OF CURVATURE P.C.P. = PERMANENT CONTROL POINT P.D.E. = PRIVATE DRAINAGE EASEMENT P.G.E. = PRIVATE GAS EASEMENT P.K. = PARKER KALON NAIL P.O.B. = POINT OF BEGINNING P.O.C. = POINT OF COMMENCEMENT P.P. = POWER POLE P.R.M. = PERMANENT REFERENCE MONUMENT PROP. = PROPOSED P.T. = POINT OF TANGENCY P.U.E. - PRIVATE UTILITY EASEMENT R = RADIUS RAD. = RADIAL • = MEASURED TO END OF BOARD LOT 63 41 �PG�ti its. 0 'LD 4) Jtv' LOT 64 S.B.T. z5g1 d`9o04 \ 2556 2 j•, T.O.B. R/W = RIGHT-OF-WAY SAN. = SANITARY S.B.T. = SOUTHERN BELL TELEPHONE S.F. = SQUARE FEET T.O.B. = TOP OF BANK TYP. = TYPICAL U.E. = UTILITY EASEMENT U.L.P. = UPLAND .PRESERVATION 0 = SET 5/8" IRON ROD WITH CAP NO.'LB 6674 0 = FOUND 5/8" IRON ROD WITH CAP No. LB 6674 = FOUND PERMANENT CONTROL POINT p = SET P-K NAIL WITH DISK NO. LB 6674 A = FOUND P=K NAIL No. LB 6674 0 = WATER SERVICES D4 = WATER VALVE = SANITARY SERVICE ❑ = FOUND PERMANENT REFERENCE MONUMENT 6674 000 = EXISTING ELEVATION IN FEET 0.00 > = PROPOSED ELEVATIONS IN FEET —,N = DRAINAGE FLOW INDICATOR � M��gGFM E.O.W. \ FNT \qkF TRq C 4�9a \ rN0 \ 4 Og2�•546,3. R, 00, 0 = SET 5/8" IRON ROD WITH CAP WITNESS CORNER LB #6674 o 1.0' OFFSET 0 = ELECTRIC SERVICE = CATV = LIGHT POST Mom, �4 4' a 56 a a�o4 'S3 iq, MIN, I1 SET'!EC FRONT- 0 a C9 w a' N ln' M SIDES CNR SIDES HEAR� . h a� C CIO? ZN 1 LOT 65 TECH - < o ry' ti a moo• c SAN. FjRST , �80 00, M.H. 40, Rq��ERO T R, q0 DESCRIPTION:' BEING ALL OF LOT 64, ACCORDING TO THE PLAT OF POD 33 AT THE RESERVE, PHASE.I - KINGSMILL, AS RECORDED IN PLAT BOOK 38, PAGES 13, 13A THROUGH 13C, PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. T. ON oNCOPAvr & VACVe F � T RgNSF RMER o 4i .T. R=500.00' p=0°37'46" L=5.49' \ mom SURVEYOR'S REPORT: I, THIS SURVEY IS PREPARED FOR RESERVE HOMES, LTD. L AND IS NOT ASSIGNABLE. 2. THE LANDS SHOWN HEREON WERE NOT ABSTRACTED FOR EASEMENTS AND/OR RIGHTS -OF -WAY OF RECORD BY THIS OFFICE. 3, VISIBLE ENCROACHMENTS ARE AS SHOWN. 4. DESCRIPTION FURNISHED BY CLIENT. 5. NOTICE: THERE MAY BE ADDITIONAL RESTRICTIONS THAT ARE NOT RECORDED ON THIS SURVEY THAT MAY BE FOUND IN THE PUBLIC RECORDS OF THIS COUNTY. 6. THIS SKETCH IS THE PROPERTY OF LAWSON, NOBLE & WEBB, INC. AND SHALL NOT BE REPRODUCED IN WHOLE OR PART WITHOUT THE PERMISSION OF LAWSON, NOBLE & WEBB, INC. IN WRITING. 7. BEARINGS SHOWN HEREON ARE BASED ON THE W'LY LINE OF LOT 64 WHICH BEARS N 29'22'11" E AND ALL BEARINGS ARE RELATIVE TO PLAT. 8. BOUNDARY DIMENSIONS SHOWN ARE PER PLAT AND FIELD MEASUREMENT UNLESS OTHERWISE NOTED. 9. ELEVATIONS SHOWN HEREON ARE BASED ON N.G.V.D. ADJUSTMENT -OF 1929. 10. LANDS SHOWN HEREON .LIE. WI'i HIN ZONE X ACCORDING TO THE FLOOD INSURANCE RATE MAP PANEL, NO. 120285-'0275F- DATED AUGUST 19, 1991 11. IMPROVEMENTS IF ANY ARE AS SHOWN. 12 DATE OF FIELD SURVEY: JANUARY 3.1, 2001 CERTIFICATION: IMPROVEMENTS; IF ANY, ARE AS•LOCATED. NOT VALID WITHOUT THE SIGNATURE ,AND THE ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. JULIAN D. MORRIS , PROFESSIONAL SURVEYOR AND MAPPER FLORIDA REGISTRATION NO. 4731 i B319LS64,dwg 6-4-01 10159104 are EST .MAP OF BOUNDARY SURVEY CLIENT: RESERVE HOMES, LTD. LB ;# 6674 LNW • • • • • ® • • • • • 000• Lawson, Noble & Webb, Inc. E N 0 1 N E E R 8 PLANNERS SURVEYORS 590 NW Peacock Boulevard, Suite 9, Port St. Lucie, Florida 34986 (561) 878-1700 • fox: (561) 878-1802 • email: Inw-pslalnw-inc.com West Palm Beach • Port St. Lucie Plantation REVISION FB/PG DATE BY CK'D DATE: 1-31-01 IOARD TIE IN POD 59 6-1-01 MJM JDM BY: JDM CK'D: GRB F.B.:POD 33-3PG:4 JOB NO.: B319