Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSDATE: 1_16-1ZA- PERMIT NUMRF1k: -)Dal .. G-vw PLANNING & DEVELOPMENT SERVICES DEPARTMENT BUILDING & CODE REGULATIONS DIVISION 2300 Virginia Avenue Fort Pierce, FL 34982 SCANN (772) 462-1553 ED APPLICATION FOR REPLACEMENT OF St. Lucie Cou.ty - WINDOWS, SKYLIGHTS, DOORS & OVERHEAD GARAGE DOORS 1. LOCATION/SITE ADDRESS: Z/ �9 95' . a 10) /1P V P1.6 el 2. PARCEL ID NUMBER: 1 ji,? - 1,Y / - C 0'0-3 -- 06 67 - 3. DESCRIPTION OF PROJECT OR WORK ACTIVITY: AleW.- 911'ra,5e- hc1a)r- WX7' 5:0LMX0 Cny- 5�0'm'p - - 4. TYPE OF STRUCTURE: SFR MOBILE HOME OTHER 5. OWNERS INFORMATION Name: e- Ve tJ Address:.q995. C'6n)-ei f'ja I-f_. f city: t —stab: Z� I zip: 3'-j Phone: 7_'�5 5. 6. CONTRACTOR'S INFORMATION FL Reg/Cert #: County Cert #: BusinessName: 0--0ccjciL_ ber,­_�;a1eS LLC Phone Number:— *12d -c-,M o3 eD Windows, Swing Doors, Skylights, Fixed Glass Opening Design Pressure A.S.C.E - 7 Design Pressure Product Manufacture � I wck-o e Model # Method of Attachment # Florida Product Approval # C r-,- Vj ct 120 mph [130 mph [140 mph )0,3 Windows & Skylights Exposure B T Exposure C Overhead Garage Doors < 30'- F.B.C. Table 1609.6 (1) + 1609.6 (2) 17!� B- Size C- Size 7. VALUE OF CONSTRUCTION: S FEES DUE: M5, RECEIPT: -0 MCT F? — Z K 0 P0 W OWNIER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in M compliance with all appficable laws regulating construction an onin C: M RC, M Cn PRINT QUALIFIERS/OWNERS NAME S143NATUR STATE OF FLORID& COUNTY OF Luc��E 'OF QUALIFIER/OWKER- - DAY OF -3a il 20j ACKNOWLEDGED BEFORE ME TfflS t7 _�, BY I WO IS PERSONALLIFWN TO ME OR WHO 14AS PRODUCED L e- AS IDENTIFICATION. e 1-0 P)-44Rry VGNAT�0� 'MOT)MY TYPE OR PRINT NAW OF IQO­TA_R7_ TinE: NOTARY PUBLIC COMNUSSION NUMBER NOTICE TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING ST. LUCIE COUNTY Vinyl Siding TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT [] Attach 2 copies of the NOA or Florida approval with details to the product being used. INSTRUCTIONS Please complete all information in the space provided. All information must be Printed (use black or blue ink only) or Typed. This application for replacement of Windows, Skylights, Doors & Overhead doors to be used for only those activities that are not otherwise included under a primary building permit. This application for Permit may not be used for any activity that includes any type or kind of structural alteration. Building activities involving structural alteration, in addition to the replacement of Windows, Skylights, Doors & Overhead doors, must be permitted through the regular building permit review process. The information to be provided with this application includes: I LOCATION/SITE ADDRESS: ............................................. Indicate the street address, or general location, of the property on which the building activity is taking place. PARCEL ID NUMBER: ........................................................ Indicate the Property Tax Identification Number for the Property on which the building activity is taking place. 3. DESCRIPTION OF PROJECT OR WORK ACTIVITY ........ Briefly describe the building activity under permit application. 4. OWNERS INFORMATION: ................................................. Indicate the name and address of the owner of the property on which the product is to be installed. 5. CONTRACTORS INFORMATION: .................................... Indicate the State of Florida (if applicable) and SL Lucie County contractors registration numbers, and the name of the business doing the work. 6. VALUE OF CONSTRUCTION: ........................................... Indicate the total value of the work to take place. Total cost of construction includes all material and labor costs associated with the building/construction activity. The value of construction is used to determine the amount of permitting fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction. All applications for Permits are to be submitted to die St. Lucie County Building and Zoning Department, St. Lucie County Administration Building, 2300 Virginia Avenue, Fort Pierce, FL 34982. All applications for Permits must be complete and filed with the Department no later 4:30 P.M. each business day. No applications will be accepted for processing after 4:30 P.M. For assistance in completing this application, please contact the St. Lucie County Building and Zoning Department, at (772) 462-1553, during regular office hours (8:00 AM - 5:00 PM), Monday through Friday. Following the issuance of this Windows, Skylights, Doors & Overhead doors replacement Permit, the scheduling of all required inspections maybe made by calling (772)462-1261. SLCCDV FORM NO: oo6-05 1. � . . J, L V I V­ I I - J F I lilt \/AJA"AV SCIS H&A, Log li,% U&q, ft)WjWn M= W 700iN Submit Sitrthgrge SEM S, Facts Publicaws FOC Staff 8('tS Sitq mo Un" Sa,c ProduCt Approval USER: ftwit: VW L"Ovff-UP-0.��tleou > 2md,,.mt > FL FL5249-R6 Application Type Revision Code Version 2007 Application Status Approved Comments Amhlved Product Manufacturer Wayne -Dalton, a division Of Overhead Door Corporation Addressl Ph Orie/ Ern aji 3395 Addison Drive Pensacola, FL 32514 (8SO) 475-6000 gtaylor@Wayne-Dalton,rom Authorized Signatures Greg Taylor qtaylOr@V� Dyne- Da Iton. cc m Technical Representative Greg Taylor Address/ Ph one/Ema if 3395 Addison Drive Pensacola, FL 32514 (850) 474-9890 gtaylOr@wayne-dalton.cdm Quality Assurance Representative Add ress/Phone/ Email Category Exterior Doors Subcategory Sectional Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect �r a Ucense- Florida Professional Engineer i! Evaluation Report - HardCopy Received Florida Engineer or Architect Name who 3effrey P. Arneson developed the Evaluation Report Flor'scla Ucense PE-58544 Quality Aussurance Entity Intertek Testing services NA Inc. - ETUWarnock liersoy Quality Assurance Contract Expiration Date 03106/2020 Validated By Dole J. Kelley Validation Checklist - Hardcopy Rerelved Certlflcate of Independence FLU248 R6 COI r _Qe�nd. dg Referenced Standard and Year (of Standard) 2WDAAEd ANSI/DASMA-108 ANSI/DASMA-115 TAS-201 TAS-202 TAS-203 Year zG02 200S 1994 1994 1994 http://www.floridabuilding.org/pr/Pr�_app_dd.aspx?param=wGEVXQwtDq qj.,neb8QjbxRy. 11/3/2011. 5/16-18 SOLT & NU T ��R SLOT AND 1/4-20xg/16* '_T - 1/4-20 14EX NUT AN' TWO ALIGNING ROLES 'A COMMERCIAL W FRAME 1(4) 1/4-14.7/8' SELF r rfi / ,t'-. I LD (2) 1/4-140/8" _� .1. DRILLING CRIMPTITE SCREWS l��LLJ (INSIDIE OF EACH END HINGE)-,__ NYLON STORMCARD ROLLER H 4-1/2" STEM AND 6" PUSHNUT AT EACH .UER LOCATION. 1/4- MAX [WEEN PUSHNUT AND kCKET OR HINGE WIDE BODY END ATTACHED � �TH�� 4-141c5/8" LF DETAIL 8 G SCREWS 18 CA NARROW BODY GE INTERMEDIATE Hlhl� ATTACHED WITH (4) 1/4-14x5/8' SELF TAPPING SCREWS DETAIL C 14 CA BOTTOM BRACKET ATTACHED WITH (2) 1/4-140/8" SELF DRILLING CRIMPTITE SCREWS THROUGH STRUT AND BOTTOM BRACKET AND (1) 1/4-146/8" SELF DRILLING TAMPER RESISTANT l< Q 16' q: 14' & 15' (12) la GA 80 KSI U—BARS LOCATED AS SHOW4 �7) SCCTION DOORS MTH (11) 3 1 8 CA 9� KSI U—BARS LOCATED AS SHOWN rm-iil7 _0 EMS I =1i Owl Mill"011 v v (16) #8.3/4" MIN STAINLESS SCREWS WTH STAINLESS BACKED RUBBER WASHERS 1/8' BEAD GE ULTRAGLAZE SSG4000AC STRUCTURAL SEALANT OR EOUIVALENT DFTAII D FACER STEEL --- NON—STRUCTURAL v DECORATIVE INNER L MNOOW TMRIM;��_. DETAIL E i6) S (9) 3 is �5) SECTION DC (8) 3 18 CA 80 KSI LOCATED fi (4) SECTION DOORS WITH (6) 3- 18 CA 80 KSI U—BARS LOCATED As SHOWN NON—S"IRUCTURAL DECORATVE OUTER WINDOW TRIM 1/4- POLYCARBONATE I umv__ 1"qmlq� B 'IN Mftn MARK R. BARROW, PE 3395 ADDISON DRIVE FLORIDA LICENSE NO. 57389 PENSACOLA. FLORIDA 32514 TEXAS LICENSE NO. 93119 (850) 474-9890 I� ATTACH U—BAR WTH (2) 1/4-140/8" SELF DRILLING CRIMPTITE SCREWS AT EACH STILE LOCATION, TYP. STATIC PRESSURE RATINGS I APPROVED SIZES DESIGN (PSF): +30.00/-33.50 IMAX WIDTH: 16'—C)- TEST (PSF): +45.00/-50.25 IMAX HEIGH T: 14*-0" IMPACT/CYCLIC RATED (YES/NO): YES IMAX SECTION HEIGHT: 21 MODELS 8000/8100 WINDLOAD SPECIFICATION OPTION CODE 1123 IPI MODIFIED NOTES TO EI AT LOUVERS .T '.PAC E S�l T T. I—ArKET SCHEDI - ILE JALLONNG REPLACEMENT OF 01 NTH JB_US. IADDED PACT RF�JvTAIMM('r Tn Mn— [ADDED MAX GLAZING TO ..S I I I SHFFT I AMPn TRArw TO FLAG CONNiCTION NOTE. CRT 11/10/07 5N. ADDED TEXAS NSE NUMBER TO E BLOCK. ADDED CT RESISTANT 3NC. 9/19/08 N.T.S. SIZE: A DATE NAME 1 1 5/22/06 GIRT EDI 1/22/07 MRB SHEET 2 OF 2 DRAWING PART NO. REV. 3270 I P3 W�ACT RES,3TANT GLAZING OPTION- IMPA�'T RFt;ISTAi4T GLAZINC SYSTEM MAY BE INSTALLED Ilq T('P OR INTERMEDIATE SECTION (WITH OR *171"OU'. DECORATIVE INSERTS). GLAZING SHALL. BE 1/4- MAKROLON-AR POLYCARBONATE OR EQUAL. MAXIMUM GLAZING DIMENSIONS SHALL BE 16.56- 12.26*. SEE DETAIL E ON SHEET 2 FOR ASSEMBLY DETAILS. 2. NON -IMPACT REISTANT GLAZING OPTION - 090" MINIMUM SSB GLAZING IN MOLDED FRAMES SCREWED TOGETHER WITH A MINIMUM OF (10) 080" SCREWS INSTALLED IN TOP OR INTERMEDIATE SECTION (WITH OR WTHOUT DECORATIVE INSERTS) MEETS UNIFORM STATIC WIND PRESSURES SHOWN ON THIS DRAWING. GLAZING SHALL HAVE A MAXIMUM HEIGHT OF 10.69" AND A MAXIMUM LENGTH OF 16.94'. GLAZING IS NOT IMPACT RESISTANT AND DOES NOT MEET THE REOUIREMENTS FOR WIND-BORNE DEBRIS REGIONS 3. VINYL OR WOOD DOOR STOP NAILED A MAXIMUM OF 6' O.C. MUST OVERLAP TOP AND BOTH ENDS OF PANELS MINIMUM 7/16- TO MEET NEGATIVE PRESSURES 4 KEY LOCK, SLIDE LOCKS. OR OPERATOR OUIRED. LOlJVER OPTION - .040' MINIMUM LOUVERS IN MOLDED FRAMES SCREWED TOGETHER WTH A MINIMUM OF (10) 18xl' SCREWS INSTALLED IN THE BOTTOM SECTION. LOUVERS ARE NOT IMPACT RESISTANT AND DO NOT MEET THE REOUIREMENTS FOR WIND-BORNE DEBRIS REGIONS, 6. SECTION STEEL TO HAVE A MINIMUM 26 GA THICKNESS. 7. THE DESIGN OF THE SUPPORTING STRUCTURAL ELEMENTS SHALL BE THE RESPONSIBILITY OF THE PROFESSIONAL OF RECORD FOR THE BUILDING OR STRUCTURE AND IN ACCORDANCE WTH CURRENT BUR -DING CODES FOR THE LOADS LISTED ON THIS DRAWNG. & DOOR JAMB TO BE MINIMUM 2.6 STRUCTURAL GRADE LUMBER. REFER TO JAMB CONNECTION SUPPLEMENT FOR ATTACHMENT TO SUPPORTING STRUCTURE. 9. FOR LOW HEAD ROOM LIFT CONDITIONS, TOP BRACKET SHALL BE A 13 CA LHR 7/4 TOP BRACKET WITH A MINIMUM OF (3) 1/4-14.7/8' SELF DRiLLING CRIMPTITE SCREWS IN LIEU OF THE: BRACKET SHOWN ON THIS DRAWING. U-8AR ON TOP SECTION SHALL BE INSTALLED ON TOP OF LHR TOP BRACKETS. SUPERIMPOSED DESIGN PRESSURE DX'R I DOOR I UNIFORM LOAD EACH JAMB (PLF) 7H HEIGHT i3 rA Hrjrl: .%UE I" ',A F0C AN�&E 16 rA LON HCFr.Z 7RACK 5/160-5/3" LAG SCREW (%N 3 AS SHOWN) (4) 1/4-204/16- LARGE 14EAD TRACK BOLTS OR 1/4-20 STUDS WITH 1/4-20 HEX NUTS 16 CA MIN VERT TRACK 1/4-20xg/16* TRACK DOLT AND 1/4-20 HEX NUT AT EACH JB-US JAMB BRACKET LOCATION 5/160-5/8' LAG SCREW AT EACH JAMB BRACKET 15 CA STIFFENED JAMB BRACKETS SEE SCHELDULE FOR OUANITY. LOCATION, AND TYPE KEY LOCK OR SLIDE LOCK EACH END (NOT REQUIRED WTH OPERATOR - SEE NOTE 4). SLIDE LOCK SHOWN FOR CLARITY NOTE� (4) SECTION S DOOR SHOWN. SEE SHi 2 FOR U-SAR LOCATIOI ON DOORS WITH OTHER SECTION QUANTITIES AN SEE NOTES I AND 2 TI­ SHEET FOR GLAZING OPTIONS, JAMB BRACKET SCHEDULE DOOR HEIG14T — NO. OF SECTIONS —4 NO ' OF JAMB BRACKETS (EACH J"S) TRACK TYPE LOCATION OF CENTERLINE OF JAMB BRACKETS MEASURED FROM BOTTOM OF TRACK (ALL DIMENSIONS 1 2-) 7-7 6 01 (JO-US). 14' (01), 23-1/2' (JB-US). 34" (JB-US). 44' (01). 56'-(—JB-US) V-111" 4 6 FAT (JI3-US), TO- (JB-US). 21-3/4- (JB-US). 39- (JO-US), 48- (JB-US). 57-1/4- (JB-US) 7'-0' 4 6 ol (JB-US). 14- (0). 25-1/2- (JB-US). 34- (JO-US). 44- (04). 63-1/4- (je-US) 7'-0" 4 6 FAT --US). 10 I (JB-US). 10- (JB-US - 15-3/4- (JB-US), 36- (JB-US�, 52-1/2* (JB-US), 63-1/4- (JB-US) 7'-r,' 7.-6. 5 5 8 2 ol FAT �.AT F4� �_/2 (JB-U5). 32-1/2- (JB-US). 43- (01), 49- (JB-US). 62-1/2- 72' J" US21/2 (JB-US). TO- (JB-US). 22-3/4- (JB-US), 36- (JB-US), 45- (JB-US). 54-1/4' (JB-UST , il 7 (5i 5(S). 1. JB - 'US) a'-o' 8--o- 5 5 '8 a a ol F FAT F 24" (Qll. 21 ('JBEUS� (18-US). 34' (JB-US). 46" (01). 2::jj�2' 75,- (JB-US 0- (JB-US). 25-3/4- (JB-US). 39- (JB-US). US� "o-US). 73-i/2- Oto-us) JB� d S' . , lJ -OW — a--ol I �S) FOLLOWING DIMENSION DENOTES SLOTTED JAMB BRACKET ATTACHED TO TRACK NTH 1/4-20xg/16* TRACK BOLT AND NUT. FOLLOWNG DIMENSION DENOTES QUICK INSTALL JAMB BRACKET INSTALLED IN BUrTERFLY SLOT. NO ADDITIONAL HARDWARE NEEDED TO ATTACH TO TRACK. DOORS GREATER THAN 8' IN HEIGHT REOUIRE USE OF CONTINUOUS WALL ANGLE SFF �,IIPPLEVENT TRACK C�IAIZT FOR DETAILS. RENISIC'eirl- _. MCMED NOTES -0 �Tt_ THAT LOU'�EAS E NOT IMP�CT PSTANT. r 6/29/07 MODIFIED JAMB kCKET SCHEDULE .OWING REPLACEMENT Cl WITH JB_US. )ED IMPACT ISTANCE TO DOOR. )ED MAX GLAZING ENSION TO NOTES ET 1. ADDED TRACK FLAG CONNEC7iON 'E. 11/10/07 MODIFIED LOUVER ION. ADDED TEXAS -NSE NUMBER TO _E BLOCK. ADDED 9/19/08 blATIC PM55URE RATINGS APPROVED SIZES [SCALE: N.T.S. __FvZE. A '551 md.ov-7,3.50 IMAX Wil) 111- I TEST (PSF): +45.00/-50.25 1 MAX HFICHT: W-O" Int?AM 7,- =7 .—M 'I'Es MAX SLCIION HEIGHT: 21'ICHECKEDI 1/22/07 MR8 MODELS 8000/8100 SHEET 1 OF 2 MARK R. BARROW. PE FLORIDA LICENSE NO. 57389 3395 ADDISON DRIVE DRAWING PART NO. REV. TEXAS LICENSE NO. 93119 PENSACOLA. FLORIDA 32514 (850) 474-9890 WINDLOAD SPECIFICATION OPTION CODE 1123 327017 I P3 Nov. 1 2 0 1 0h I I : 4 0 AM Online No. 5477 Pal'. 3 o,,' . r Approved for use outside HVM2: Ye5 Impact Ites1stant: No Design Pressure: -�-15.30/-17.00 Other; Glazing is not impact resistant and does not neel: the requirements for wind -borne debris regions. 100 #1122 Atnits of Use Approved for use in HVHZ. No Approved for use outside HVHZ; Yes Impact Resistant; No Design Pressure: +23.001-2S.00 Other; Glazing Is not Impact resistant and does not reet the requirements for wind-borne debris regions. FLRZJ R,6 11 307494 P8 TrAek Suppj_ement Ch.Xt..Qdf, FL8248 I amb nn ton Oiuppleme &XQ pdf Verified by: Ieffrey P. Arneson FLORIDA PE S8544 Created by Independent Third Party: Yes !valuation Reports FL824Q Rfi Af--FLAL4fl-Evaivatior_R.PjlQjl_-ML- Created by Independent Third Par1r, —Yes 16' May, width. 14' Max height. Glating avail,able in top oi, AMIlation Instructions E"-Z§_U_�J22 P3 f FLBZ48 R6 11 30749A-UTrack SyApj1_m_ULChiirLpdf FL8248 R6 LI �aMtl_�-,=Wjqri SypUl mpnl_P A. Verified By: Jeffrey P. Arrieson FLORIDA PE 58544 Created by Independent Third PaMy: Yes .valuation Reports FL8248 R6 AE FL8248 EvafWation Repart -.§Q0 rCZ�ed by Ind ---- Ae— T$,;.A i LL—Y—es --- 1 16' Max width. 14' Max height. Glaving available in top Cr 18248.7 Intermediate section. .. Limits of Use Installation Instructions Approved for use In HVMZ: No ELD2gLu 11 lulka-Ra Approved for use outside HVHZ: Yes FLO 40 R6 11 307401-MTrack L - f FL8248 R36 I )SIMh ('oQ09CtiQMjAPP eMjC—tP-9L3I1 Impact Resistant; Yes I>esign Pressure: +30.00/-33.50 Verified By: Jeffrey P. Arneson FLCRIDA PE 58544 Other; Created by Independent Third Party: Yes Evaluation Reports F 0 Created by Independent TWrd Partait- 8248,8 8000/8100 01124 116- I Max width. 14' Max height. Glazing available I i i iintermedlate sectlom. -Imits of use Approved for use in HVH7: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure* +34.40/--36.30 Other; 01800 01125 -ImIts of Use Approved for use In HVHZ! No Approved for use outside HVHZ, Yes Impact Resistant: Yes Design Pressure: +46.00/-S2.00 Other: 10 18000/8100 #1141 Umlts of use Approved for use in MVKZ: No Approved for use outside HWIZ: Yes Impact Resistant: No Design Pressure; +18.50/-20.70 Other: Glazing Is not impact resistant and does not meet the requirements for wind-Dorne debris rtgions. 11 1800018100 01142 rnstaillation instructions L02AUM-J"12-4-F-IRdt ELU a R6 11 307421 Pft Track StL2;ijj=��hart-udf FLO748 Jamb Connectign 5ijaQlement P8. 99 Verified By: Jeffrey P. Arneson FLORIDA PE 58541 created by independent Third Partf: Yes Evaluation Reports 6' Max width. 14' Max height, Glazing available in top 9, :nstallation Instructions FLO14a R6 H 307494 PS TpCk SLt2p emenljChj�J-D�f Verlified By: Jeffrey P. Arneson FLORIDA PE 3854-1 Created by Independent Third Partv: Yes Evaluation Reports iated,by Independerit Third Parl�,r: Yes Max vvidth. 14' Max height. Glaz ng available In top Installation instructions ELft�IU1j-iLP-3--P—CLf 07494 PP_Tratk SLPP.WMCMj-Ch&j4W Verined By: Jeffrey P. Arneson FLORIDA PE !;$S49, Created by Independent Third Party: Yes Evaluation Reports 10'MaX width. 14' Max height, Glazing availat)le ir top Limits of Use installation instructions Approved for use In HVHZ: No FLO248 142 P3.IZSLf Approved for use outside HVH.Z: Yes http-://www.floridabuildinE _/pr/pr_app_dd.aspx?param=wGEVXQ,; juimeb8iGhRy... 11/3/201 Jan, 26, 2011. 8: 1 OAM, , No. 5989 1?ajP. M r wi tud vUAjU4rjjS 99P.Hmerlt of Community AtNim Florida B&,Ildf.p Code Wiling COde5 and St*Hda?dk -.�5s Shum3rd Oak eoulcvard rgi;��,"ee, nofd; 32299-2100 fSSC) 407-1624, F4X (1950) 414-6436 tt, 2CY10-2010 The 5titq of �Icrida. All rights raservetd. j S;VjtqpqL. �e_.5"" j I Contact VA A _1 I F -jrjyj� product Approvilif ACCOPTS: WMERE NEW httt)-//wxvxv flinrldabuilding.or2/m/m am) dti.asox?Daram=wCjEVXQwtDqui)iie.b8Cib�,Ry... 1 /26120 j SCHEDULE3 3/8"0 A307 HEADED OR HOOKED ANCHOR BOLTS LOAD PER JAMB LB/FT NOTE 3 MAXIMUM SPACI G OF ANCHOR BOLTS PER JAMB (IN) 2000 PSI 2500 PSI 3000 PSI CONCRETE CONCRETE CONCRETE 100 24 24 24 120 24 24 140 24 24 24 160 24 24 24 18� - 24 24 24 2W 24 24 24 220 24 24 24 240 24 24 24 260 24 24 24 280 24 24 24 300 24 24 320 24 24 24 340 23 24 24 360 22 24 24 380 21 T3- 24 400 20 22 23 42 19 21 22 440 18 20 21 460 17 19-- 204 480 16 78 19 500 16 18 18 520 15 17 18 540 14 16 17 560 14 16 16 580 13 15 16 600 13 15 15 62013 14 15 64012 14 14 660 12 13 14 68011 13 13 700 11 12 13 720--Il 12 13 740 10 12 12 760 1 10 11 12 780 10 11 12 800 10 11 11 1. BASED ON 3/8"0 A307 HEADED OR HOOKED ANCHOR BOLTS WITH A 1"O.D. WASHER WITH A MI�IMUM EMBEDMENT DEPTH OF 3" AND A MINIMUM EDGE DISTANCE OF 3". 2. PROVIDE QUANTITY OF ANCHOR BOLTS AS REQUIRED TO MAINTAIN MAXIMUM SPACING AS SHOWN IN TABLE WITH A MINIMUM OF THREE (3) ANCHOR BOLTS PER JAMB. ANCHOR BOLTS AT TOP AND BOTTOM OF JAMB SHALL BE PLACED A MAXIMUM OF 6" FROM THE END OF THE JAMB. 3. LOAD PER JAMB CALCULATED BY TAKING DESIGN LOAD (PSF) TIMES DOOR WIDTH (FT) DIVIDED BY 2. EXAMPLE: DESIGN LOAD 30psf DOOR WIDTH 16ft LOAD PER JAMB = 30psf x 16ft/2 = 2401b/ft 4. CHART IS BASED ON 6'-6- MINIMUM AND 24'-0" MAXIMUM DOOR HEIGHT. 5. CHART INCLUDES A SAFETY FACTOR OF 4. 6. DOOR JAMB TO BE 2x6 NO. 2 GRADE SPF LUMBER OR BETTER MOUNTED DIRECTLY TO SUPPORT STRUCTURE. 7. DESIGN OF THE SUPPORT STRUCTURE SHALL BE THE SOLE RESPONSIBILITY OF THE BUILDING DESIGNI:R AND SHALL BE DESIGNED FOR THE JAMB LOAD LISTED IN ABOVE TABLE AS CALCULATED PER NOTE 3, 8. CALCULATIONS CONFORM TO ANSI/AF&PA NDS-1 997 AND ACI 318-02. Approved Mark R. Barrow, PE Florida License No. 57389 Wayne Dalton Corp. 3395 Addison Drive Pensacola, FL 32514 Revision :7 Property Appraiser - St.Lucie — nty, FL Page I of I PROPERTY RECORD CARD George W Fendley Record: 1 of 2 <<Prev Next >> Spec.Assmnt Taxes Exemptions Permits Home Print Property Identification 0 Site Addressi 4995 Conley PI ParcelID- 1313-131-0003-000-8 Sec/Town/Range: 13:34S :39E Account #: 4672 Map ID: 13/13N Land Use: SF Res Zoning: RS-4 City/Cnty: St Lucie County %jk Ownership and Mailing Legal Description Owner- George W Fendley 13 34 39 W 247.37 FT OF E 433.37FT OF N 338.5 FT OF SW 1/4 OF Address: 4995 Conley PI NEI/4 (OR 3265-1101) Fort Pierce FL 34951-3226 Sales Information Assessment 2011 Final Total Land and Building Date Price Code Deed Book/Page 2011 Final: 125800 Land Value: 25900 Acres. 1.92 11/22/2010 150000 0112 SID 3265/1101 Assessed: 125800 Building Value: 99900 4/20/2010 100 0112 CT 3198/0174 Ag.Credit: 0 Finished Area: 2013 SqFt 8/17/2005 390000 00 WD 2362/0597 Exempt: 6/7/2000 100 01 QC 1306/0928 Taxable: 5/12/1995 26000 00 WD 0956/0124 Taxes: 2559.49 BUILDING INFORMATION (.1 Exterior Features View. RoofCover: SD - Dim Shingle RoofStruct: HP - Hip ExtType: HC - HC YearBlt: 1996 Frame: Grade: C-C EffYrBIt: 1996 PrimeWall: BS - CB Stucco StoryHght: 0010-1 Story No.Units: 1 SecWall: Interior Features BeclRooms: 3 Electric- MX - MAXIMUM PrmIntWaII: DW - Drywall FullBath: 2 HeatType: FHA - FrcdHotAir AvgHt/Fl: 1/26ath: 0 HeatFuel ELEC - Electric Prm.Flors: CU - Carpet %A/C. 100 %Heated. 100 %Sprinkled: 0 Special Features and Yard Items Land Information Type Y/S Qty. Units Qual. Cond YrBIt. No Land Use Type Measure Depth DWC - Driv-Concret Y 1 2025 AV AV 1996 1 0 1 00-S F Res 535 -Acres 1.92 FEN4 - CHAINLINK 4' Y 1 1119 AV AV 1996 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED http://www.paslc.org/prc.asp?prclid=131313100030008 1/10,