Loading...
HomeMy WebLinkAboutAgenda Packet 07.16.2026 PLANNING & ZONING COMMISSION AGENDA ST. LUCIE COUNTY Regular Meeting Thursday, July 16, 2026 6:00 PM St. Lucie County Commission Chambers 2300 Virginia Avenue 3rd Floor of Roger Poitras Building Fort Pierce, FL 34982 BOARD MEMBERS CHAIRMAN RYAN BINNER VICE-CHAIRMAN LAWRENCE “BEAU” SLAY BOARD MEMBER JOSHUA BRADLEY BOARD MEMBER DARREN GUETTLER BOARD MEMBER ED LOUNDS BOARD MEMBER WILLIAM O’DELL AT-LARGE BOARD MEMBER LARRY NEESE EX-OFFICIO BOARD MEMBER NICOLE FOGARTY Mission Statement Committed To Service, Focused On Our Future, Grounded By Tradition Page 1 of 456 Regular Meeting Thursday, July 16, 2026 6:00 PM 2 | P a g e WELCOME • Please turn off all cellular phones and pagers prior to entering the Commission Chambers. • Please note that the Planning and Zoning Commission/Local Planning Agency serves in an advisory capacity to the St. Lucie County Board of County Commissioners and has the power to review and make recommendations to the Board, for approval or disapproval, on any applications within their area of responsibility. • The Planning and Zoning Commission strongly encourages your input and comment at the public hearing. Please limit comments to three minutes if possible and be respectful of others’ opinions. • For public convenience, all meetings are televised and are provided with wireless internet access. NOTICE: All Proceedings before this Board are electronically recorded. Any person who decides to appeal any action taken by the Board at these meetings will need a record of the proceedings and for such purpose may need to ensure that a verbatim record of the proceedings is made. Upon the request of any party to the proceedings, individuals testifying during a hearing will be sworn in. Any party to the proceedings will be granted the opportunity to cross-examine any individual testifying during a hearing upon request. Anyone with a disability requiring accommodation to attend this meeting should contact the Human Resources Department at (772) 462-1546, HumanResources@stlucieco.org or TDD (772) 462-1428 at least forty-eight (48) hours prior to the meeting. Page 2 of 456 Regular Meeting Thursday, July 16, 2026 6:00 PM 3 | P a g e 1. CALL TO ORDER 2. PLEDGE OF ALLEGIANCE 3. INVOCATION 4. ROLL CALL 5. ANNOUNCEMENTS 6. DISCLOSURE(S) 7. MINUTES A. St. Lucie County Planning & Zoning Commission minutes for the meeting of June 18, 2026. 8. PUBLIC COMMENT 9. PUBLIC HEARINGS A. Pruitt Commerce Center Rezoning and Preliminary PNRD Plan - ADEQUATE PUBLIC NOTICE FOR THIS ITEM WAS NOT ACHIEVED. THEREFORE, THE ITEM WILL BE RE-NOTICED AND RESCHEDULED FOR A FUTURE MEETING. B. Proposed Amendment of Zoning Atlas and Preliminary Development Plan for The Club at Indrio Creek - THIS ITEM IS QUASI-JUDICIAL 10. WORKSHOPS 11. OTHER BUSINESS 12. ADJOURN Page 3 of 456 PLANNING & ZONING COMMISSION ST. LUCIE COUNTY, FLORIDA Regular Meeting June 18, 2026 Convened: 6pm Adjourned: 7:28pm 1. CALL TO ORDER The meeting was called to order at 6:00 PM, by Chair Binner 2. PLEDGE OF ALLEGIANCE Chair Binner. 3. INVOCATION Commissioner O’Dell. 4. ROLL CALL Madam Secretary Tommie Marie Fowler Present Board Member Ed Lounds, Board Member Billy O'Dell, Board Member Ryan Binner, Board Member Larry Neese, Board Member Darren Guettler, Board Member Lawrence Slay Excused Ex-Officio Nicole Fogarty, Board Member Joshua Bradley 5. ANNOUNCEMENTS None. 6. DISCLOSURE(S) None. 7. MINUTES A. St. Lucie County Planning & Zoning Commission minutes for the meeting of April 16, 2026, No Meeting minutes for May 21, 2026 - Meeting Canceled A motion was made to approve all sets of minutes and it passed unanimously. Page 4 of 456 Planning & Zoning Commission Meeting Thursday, June 18, 2026 6:00 PM 2 | P a g e RESULT: APPROVE MOVER: Board Member Ed Lounds SECONDER: Board Member Larry Neese AYES: Ed Lounds, Billy O'Dell, Ryan Binner, Larry Neese, Darren Guettler, Lawrence Slay NAYS: None EXCUSED: None 8. PUBLIC COMMENT None. 9. PUBLIC HEARINGS A. Indrio Town Center - Seeking Rezoning from AG-1 (Agricultural -1) to PRW (Planned Retail/Workplace) and Approval of a Preliminary Site Plan - THIS ITEM IS QUASI-JUDICIAL STAFF PRESENTATION: Don Arellano, Planner II for St. Lucie County, Mr. Arellano, stated that all public notification requirements were met per St. Lucie County Land Development Code Section 11.00.03 and public outreach completed. Mr. Arellano presented the request to rezone an 85.29-acre site from AG-1 to PRW, approve a preliminary site plan, and extend the Urban Services Boundary 1,500 feet. He explained the proposed mixed-use town center would include up to 447,250 square feet of retail/commercial space, 16 townhomes or equivalent mixed-use residential density, community amenities, a neighborhood park, stormwater improvements, and multiple development parcels. He noted staff had removed warehouse and light industrial uses, outlined traffic, environmental, and infrastructure improvements required before final approval, and concluded the proposal was generally consistent with the Comprehensive Plan and Land Development Code. Staff recommended approval subject to conditions. APPLICANT PRESENTATION: Ms. Leah Heinzelman, Representative with Cotler & Hearing, on behalf of Glassman Holdings, explained that the proposal would implement the County's Towns, Villages, and Countryside (TVC) vision by rezoning the property to Planned Retail Workplace (PRW), approving a preliminary site plan, and a one-time extension of the Urban Services Boundary by 1,500 feet. She stated the mixed-use town center would provide retail, office, workplace, civic, recreational, and limited residential uses connected by an internal street network, extensive open space, buffers, trails, stormwater features, and pedestrian amenities. She noted the project would be built in phases, preserve environmental features where possible, improve Page 5 of 456 Planning & Zoning Commission Meeting Thursday, June 18, 2026 6:00 PM 3 | P a g e roadway and utility infrastructure, and that the neighborhood meeting received generally positive feedback. She concluded that the project was consistent with the County's long-term planning goals and requested approval. Mr. Shawn McKenzie, Traffic Engineer with McKenzie Engineering and Planning, stated the project fit within the County's planned future roadway grid for northern St. Lucie County, would provide multiple access points, and that future traffic studies would determine whether traffic signals would be needed. Ms. Catherine Rossmell, Attorney with Lewis, Longman & Walker, P.A., stated the application was a preliminary rezoning and site plan consistent with the County's Comprehensive Plan and PRW requirements. She noted the applicant agreed to all 21 staff conditions, supported the Urban Services Boundary adjustment as consistent with the County's vision for orderly growth, and requested the Planning and Zoning Commission recommend approval. BOARD & APPLICANT DISCUSSION: Commissioner O'Dell questioned the applicant's traffic analysis methodology, including the four-mile radius of influence, trip distribution, use of the County's traffic model, and whether non-residential traffic and trips originating outside the project had been adequately accounted for. Mr. McKenzie explained that the four-mile study area was based on the County's adopted methodology for projects generating more than 10,000 daily trips. He stated the trip distribution used a hybrid approach that combined the County's traffic model with projected residential growth because the traffic model did not yet include numerous pending developments. He acknowledged the methodology could be refined to better account for trips to nearby commercial uses, such as Buc-ee's, but maintained the analysis reasonably captured anticipated traffic, including non-residential and external trips, and stated no additional methodology changes were proposed before the project proceeded to the County Commission. Commissioner Lounds asked why portions of Phase 4 were left undeveloped and whether they could become residential or commercial. Ms. Heinzelman explained the final use would be determined through a future site plan review based on market conditions and County needs and clarified the area would be limited to commercial and retail uses, not residential. Chair Binner asked whether the applicant would consider reducing the maximum building heights. Ms. Heinzelman stated the applicant was open to lower building heights. Chair Binner also suggested wider on-street parking spaces and asked whether the proposed open space could include additional recreational amenities. Ms. Heinzelman stated the applicant is open to increasing the width of the on-street parking spaces and had offered to dedicate the land to the County for park use, but the County declined. She said the area would remain conservation and open space, although the applicant remained open to future discussions if the County's park needs changed. Page 6 of 456 Planning & Zoning Commission Meeting Thursday, June 18, 2026 6:00 PM 4 | P a g e PUBLIC COMMENTS: Residents expressed concerns about increased traffic, roadway capacity, and whether the existing transportation network could support the proposed development. They questioned the need for additional traffic signals, widening of Indrio Road, parking availability for commercial events and residential areas, and emergency vehicle access. Residents also encouraged smarter long-term planning, additional green space throughout the development, preservation of the rural character of the area, and requested clarification on the future uses proposed for Phase 4. One resident spoke in support of the project, citing its economic benefits, recreational opportunities, environmental protections, and consistency with the County's planning objectives. Residents Who Spoke • Justin Harrison – 6705 Pastoral Hills, Lakewood Park • Luis Aguilar – 5139 Monte Cristo Terrace • Shane Mulvey – 5320 Russakis Road • Leah Norton – 8506 Fort Walton Avenue, Fort Pierce (Lakewood Park) BOARD DISCUSSION: Commissioner Lounds asked about the proposed residential design, project timeline, and potential commercial tenants. Ms. Heinzelman explained that residential uses would be limited to 16 townhomes or mixed-use units above retail, emphasized the project's architectural standards and open space requirements, stated development timing would depend on market demand, and confirmed discussions with Publix were underway. Commissioner O'Dell urged staff to carefully evaluate future infrastructure and traffic mitigation and encouraged comparing the project's traffic analysis with the regional traffic model. Chair Binner questioned roadway access, future roadway capacity, building heights, parking dimensions, and long-term transportation planning. Mr. Benton, St. Lucie County Planning & Zoning Manager, explained the proposed street network, roadway jurisdiction, right-of-way dedication, future transportation planning, and concurrency review process, noting the project preserved flexibility for future roadway improvements while supporting the Towns, Villages, and Countryside (TVC) vision. He also stated that a three-story mixed-use building would typically be about 40 to 42 feet tall. Commissioner Slay expressed support for the project, encouraged additional green space and commercial development over residential uses, and asked what would happen if the project was approved but not constructed. Mr. Benton explained the PRW zoning would remain even if the site plan expired, although a new site plan would be required before development could proceed. Ms. Heinzelman added that Phase 4 would require future approvals because no Page 7 of 456 Planning & Zoning Commission Meeting Thursday, June 18, 2026 6:00 PM 5 | P a g e specific development was currently proposed and confirmed the property owner would maintain the conservation areas. Commissioner O'Dell moved to recommend approval with staff conditions and Board recommendations, including limiting building heights to three stories. Chair Binner requested that the motion include a recommendation to increase parallel parking space widths from six feet to eight feet, and Commissioner O'Dell amended his motion to include that recommendation. Commissioner Guettler seconded the motion with amendment. Motion to approve with staff recommendations, Board recommendations, including limiting building heights to three stories, and increasing parking spaces from six feet to eight feet. Motioner –– O’Dell Second –– Guettler RESULT: APPROVE MOVER: Board Member Billy O'Dell SECONDER: Board Member Darren Guettler AYES: Ed Lounds, Billy O'Dell, Ryan Binner, Larry Neese, Darren Guettler, Lawrence Slay NAYS: None EXCUSED: None 10. WORKSHOPS None. 11. OTHER BUSINESS None. 12. ADJOURN There being no further business to be brought before the Board, the meeting was adjourned at 7:28pm. Page 8 of 456 ITEM NO. (ID # 2026-884) DATE: 7/16/2026 AGENDA REQUEST TO: Planning and Zoning Commission PRESENTED BY: Irene Szedlmayer, Senior Planner SUBMITTED BY: Planning & Development Services SUBJECT: Proposed Amendment of Zoning Atlas and Preliminary Development Plan for The Club at Indrio Creek - THIS ITEM IS QUASI-JUDICIAL BACKGROUND: The +/-126-acre property is located south of Indrio Road, between Seminole and Emerson Roads, in the Towns, Villages and Countryside Future Land Use category and within the Urban Services boundary. The Applicant is requesting approval of the amendment of the Zoning Atlas to change the zoning district from AG-1 (Agricultural-1) to PTV (Planned Towns and Villages) and approval of a Preliminary Regulating Plan providing for 375 dwellings (single-family and townhome), two clubhouses, a flow way, outdoor recreation areas and restored/created native upland habitat. PREVIOUS ACTION: None. FINANCIAL IMPACT: No immediate impact. RECOMMENDATION: Staff recommends that the Planning and Zoning Commission receive the Applicant’s presentation, staff’s presentation, and public comment; provide input regarding the identified interpretation and modification issues; and continue the public hearing to a date certain. The continuance would allow the Applicant to submit a revised Preliminary Development Plan and supporting documentation addressing the deficiencies identified in this report. COMMISSION ACTION: RESULT: MOVER: None SECONDER: None AYES: None NAYS: None Page 9 of 456 EXCUSED: None Coordination/Signatures Date: July 10, 2026 Benjamin Balcer, Planning & Development Services Director Page 10 of 456 Planning and Development Services Department Planning Division M E M O R A N D U M GENERAL INFORMATION: Applicant: Fort Pierce Holdings, LP c/o Jared Bensky 7460 La Paz Place, Suite 101 Boca Raton, FL 33433 Property Owner: Brindhavanam, LLC c/o Sreedhar Dogiparthy 4528 Shiloh Mill Blvd. Jacksonville, FL 32246-1877 Agent of Record: Haley Ward, Inc. c/o Bradley J. Currie 10250 SW Village Parkway Suite 201 Port St. Lucie, FL 34987 Other Representatives: MacKenzie Engineering & Planning, Inc. c/o Shaun MacKenzie, PE 1172 SW 30th Street, Suite 500 Palm City, FL 34990 Existing Zoning: AG-1 (Agricultural – 1) Proposed Zoning: PTV (Planned Towns and Villages) Future Land Use: TVC (Towns, Villages and Countryside) Parcel ID Numbers: 1323-211-0005-000-8, 1314-313-0000-000-8, 1314-323-0002-000-3, 1314-331-0001-000-1, 1314-341-0000-000-5, 1314-342-0001-000-5 Parcel Size: +/-126.32 acres. TO: Board of County Commissioners THROUGH: Benjamin Balcer, AICP, Planning & Development Services Director Kori Benton, AICP, Planning & Zoning Manager FROM: Irene A. Szedlmayer, AICP, Senior Planner DATE: July 10, 2026 SUBJECT: The Club at Indrio Creek PTV – A requested Zoning Atlas Amendment for +/-126.32 acres from AG-1 (Agricultural-1) to PTV (Planned Towns and Villages) Zoning District and the Preliminary Development Plan Page 11 of 456 Project Name: The Club at Indrio Creek File No.: PD-2510-000058 Page 2 of 42 Location: Approx. 900 feet south of Indrio Road, between Emerson Avenue and Seminole Road Project Number: PD-2510-000058 Existing Use: Cattle grazing Proposed Uses: The Applicant proposes a Village in the PTV Zoning District and the TVC Zoning Overlay and Future Land Use designation. As proposed, the Village will consist of 375 (three hundred seventy- five) dwellings, two civic building lots, club houses for the townhome and the single-family home sections, a new east-west roadway connecting Seminole Road and Emerson Avenue, +/- 38 acres of open space, dedication of right-of-way, construction of a small segment of Emerson Avenue, and extension of water and sanitary sewer lines. Exhibit 1A. Aerial Map Page 12 of 456 Project Name: The Club at Indrio Creek File No.: PD-2510-000058 Page 3 of 42 Exhibit 1B. Closer scale view of subject site with parts of Lakewood Village and Waterstone displayed INTRODUCTION The proposed Club at Indrio Creek TVC Village (Indrio Creek Village) requires the rezoning of the subject +/-126.32 acres from AG-1 (Agricultural – 1) to PTV (Planned Towns and Villages) and approval of the Preliminary Development Plan. This may be the first application for the development of a TVC Village to be presented to the Planning and Zoning Commission since the option was confirmed in 2009. The proposed Club at Indrio Creek Preliminary Development Plan provides for the following: As proposed, the Village will include: ● 375 (three hundred seventy-five) dwellings (246 townhomes on +/-23-ft.wide lots and 129 detached single-family homes on 50 and 60-ft lots) ● two civic building lots ● Two clubhouses ● a new road constructed within a new east west public right-of-way (80 feet in width) connecting Seminole Road and Emerson Avenue, ● +/- 38 acres of common open space, including a flow way, restored native habitat, park and recreation areas, landscape buffers and interior lakes, ● Construction of a small segment of Emerson Avenue ● dedication of right-of-way for Emerson Avenue; ● extension of water and sanitary sewer lines likely from Indrio Road. Se m i n o l e R d . Em e r s o n A v e . Page 13 of 456 Project Name: The Club at Indrio Creek File No.: PD-2510-000058 Page 4 of 42 Exhibit 2. TVC Transferable Development Value Map BACKGROUND: TVC Historical Snapshot In 2006, following a two-year, in-depth, citizen-driven public engagement process (the North St. Lucie County Charette), the St. Lucie County Board of County Commissioners adopted the Towns, Villages, Countryside Element of the St. Lucie County Comprehensive Plan (TVC Element of the Comp. Plan or TVC Element). In 2006, the Board also amended the Land Development Code (LDC) to implement the TVC Comp. Plan Element. The LDC amendments created three new zoning districts – Planned Towns and Villages (PTV), Planned Country Subdivision (PCS), and Planned Retail/ Workplace (PRW) and established the permitted uses and development standards applicable within TVC Zoning Districts. In July 2006, the State of FL found the TVC Comp. Plan amendments not in compliance, resulting in a stipulated settlement agreement in mid-2007, followed by adoption of remedial TVC Comp Plan amendments. The TVC Element and the LDC became effective in 2009. The adopted TVC provisions were intended to be a compromise to provide developers with additional density that did not exist with the Future Land Use and zoning existing prior to the creation of the TVC, in exchange for specific development patterns, design standards, Location of Subject Site- +/-109 acres with 2 DU/A base density and +/-18 acres with 1 DU/A base density Page 14 of 456 Project Name: The Club at Indrio Creek File No.: PD-2510-000058 Page 5 of 42 open space, public spaces, provision of utilities and a roadway network to support the ultimate build-out of the TVC area. In 2011, “clean-up” type amendments were made to Chapter 3 and Chapter 4. I believe these 2011 amendments created the TVC Overlay (identical boundary as the TVC Future Land Use designation) in Chapter 4 of the LDC, Special Districts, which sought to provide an overview of and confirm the organization of the TVC code and how it applies to different sized land areas inside and outside the USB. It also added substantive standards regarding front-facing garages and driveways in the TVC. In 2020, the TVC Code was amended again to reduce the minimum time period for which workforce housing units must remain affordable from 25 years to 8 years. In October 2024, amendments to the Comprehensive Plan and the Land Development Code were adopted to provide for the Hamlet PUD (Planned Unit Development) form of development in the TVC. Development of a Hamlet was created as an option for land areas of 500 acres or larger, located outside the USB. Exhibit 3. Current Zoning Designation Page 15 of 456 Project Name: The Club at Indrio Creek File No.: PD-2510-000058 Page 6 of 42 Exhibit 4. Proposed PTV Zoning Designation ****************************************************************************** PUD PRELIMINARY DEVELOPMENT PLAN STANDARDS OF REVIEW SET FORTH IN LAND DEVELOPMENT CODE - SECTION 11.02.07. Staff reports for rezoning to a planned zoning district with a Preliminary Development Plan usually initiate with the standards of review applicable to the requested amendment of the Official Zoning Atlas. In this case, the proposed Preliminary Development Plan for the Club at Indrio Creek PTV is presented first, followed by the discussion of the standards of review applicable to the rezoning request because the details of the proposed Preliminary Regulating Plan are central to determining whether the request to rezone is consistent with the guidance and standards of the Comprehensive Plan and Land Development Code. LDC 3.01.03.EE.3. provides that the approval process for a Planned Town or Village shall be as provided in Chapter 11 of the LDC for Planned Developments, though some submittal requirements differ. LDC 11.02.07. provides that “Site plan approval shall be granted only if the applicant demonstrates the following: A. Consistency With Local Ordinances and Comprehensive Plan. B. Effect on Nearby Properties. C. Adequacy of Public Facilities. D. Adequacy of Fire Protection. Page 16 of 456 Project Name: The Club at Indrio Creek File No.: PD-2510-000058 Page 7 of 42 E. Adequacy of School Facilities. F. Environmental Impact. Each of these factors is reviewed in below. The Text of the Comprehensive Plan and the Land Development Code is provided in italics. A. Consistency With Local Ordinances and Comprehensive Plan. The proposed building or use is consistent with the general purpose, goals, objectives, and standards of [the LDC] , the St. Lucie County Comprehensive Plan, and the Code and Compiled Laws of St. Lucie County; and the proposed use complies with all additional standards imposed on it by the particular provisions of this Code authorizing such use and any other requirement of the Code and Compiled Laws of St. Lucie County. The Comprehensive Plan establishes overall goals for development in the TVC Future Land Use category as follows: Objective 11.1.4: To prevent suburban sprawl by restricting the development of lands outside of the Urban Service Boundary to a system of compact, mixed-use, pedestrian-friendly Town, Villages and Hamlets. Policy 11.1.4.1 - TVC Development. Development within the TVC is intended to do the following: • Preserve the rural character, encouraging opportunities for continued agriculture; • Offset biological and ecological impacts of new development; • Improve the water quality within the Indian River Lagoon; • Manage water comprehensively throughout the area; • Provide an interconnected system of native habitat preserves, greenways, parks, and open space; • Reduce automobile trips; • Balance housing with workplaces, jobs, retail and civic uses; • Provide a variety of housing types to support residents of diverse ages, incomes, family sizes, and lifestyles; • Create predictability and efficiency in planning and in the provision of infrastructure; • Allocate infrastructure and public service costs to provide for fiscal neutrality. Policy 11.1.4.2 - Settlement Principles. Neighborhoods form the basic building block for all new Towns and Villages within the TVC . The components of a Neighborhood shall be arranged to be compatible in scale and character with existing adjacent uses. Neighborhoods shall exhibit the following characteristics: Page 17 of 456 Project Name: The Club at Indrio Creek File No.: PD-2510-000058 Page 8 of 42 1. Neighborhood Size. The neighborhood size shall be scaled upon a five-minute walk radius (approximately ¼ mile, 1,320 feet, or 125 acres), as measured from the Neighborhood Center (Figure 11-5). In general, each neighborhood shall have well defined edges and range from 80 to 150 acres in size, not including the land set aside for the Countryside component. The shape or form of the neighborhood is flexible and responds to physical or geological conditions, provided that the maximum ¼ mile radius benchmark for scale is generally maintained. For example, proposed development within a Net Developable Area of 200 acres should create two distinct neighborhoods. 2. The Transect. A Neighborhood shall contain a mix of uses including residential, retail, office, civic and recreation spaces that support the daily needs of its residents within walking distance. Varying uses shall be organized in the Neighborhood based on the Transect, which is composed of a hierarchy of zones including the Countryside, Neighborhood Edge, Neighborhood General, and Neighborhood Center zones, and in the case of developments with multiple neighborhoods, the Neighborhood Core zone. The Transect promotes a wide cross section of uses, densities and building types and depicts their appropriate location in clearly defined zones: a) Neighborhood Edge. The Neighborhood Edge is primarily a detached single family area with larger lots and less density than the other zones. b) Neighborhood General. The Neighborhood General is one of the larger areas in a Neighborhood, allowing some small businesses compatible with the primarily residential character of the zone. A mixture of single-family homes on various lot sizes, attached townhouses, apartments, bed and breakfast tourism homes and some live-work units is appropriate. c) Neighborhood Center. The Neighborhood Center is the recognizable nucleus in the form of a public or civic focal point. The public or civic focal point may be a publicly owned square, park, green or plaza, in combination with a school, library, museum, place of worship, community center, farmer’s market or small-scale neighborhood retail uses. The Neighborhood Center provides a natural gathering place for the community and is lined by the fronts of buildings for spatial definition as well as for the increased safety afforded by the resulting natural surveillance opportunity. The Center is compact and appropriate for multi-story attached buildings designed to accommodate a range of uses over time. Shops with offices or apartments in the upper stories, live/work units and higher density residential types are all appropriate in the Neighborhood Center. The Neighborhood Center is within walking distance of and accessible to all neighborhood residents. Page 18 of 456 Project Name: The Club at Indrio Creek File No.: PD-2510-000058 Page 9 of 42 d) Neighborhood Core. The Neighborhood Core is the densest, most active zone of the Transect, supported by at least two neighborhoods usually occurring along a major thoroughfare or at a major intersection. The Neighborhood Core has the more intense retail and office uses and may include targeted industry employment uses. 3. Variety of Housing Types. A Neighborhood shall provide a variety of housing types and prices that support a broad range of family sizes and incomes. Housing types are defined by building types such as single-family, multi-family, townhouse, mixed-use, etc. and are distributed throughout the neighborhood in relation to the principle of the Transect. The Neighborhood provides home- ownership as well as rental housing opportunities in an integrated manner. The use of accessory dwelling units, . . ., to provide an opportunity for dispersed rental housing or other accessory uses within single-family fabric is desirable. Accessory dwelling units shall be evaluated for concurrency purposes to determine availability of services when proposed as part of a Town or Village. . . . Accessory dwelling units shall not constitute a unit for the purpose of limiting density. 4. Civic Uses. Each Neighborhood shall contain at least one Civic building. Civic buildings shall be sited on locations of high public visibility and prominence, usually within or around public Open Spaces, or at the termination of vistas.. . . . . . Land set aside for Civic Uses may be eligible for incentives under the Transfer of Development Rights (TDR) Program outlined under Objective 11.1.7. 5. Walkable Blocks. Blocks shall be scaled to accommodate a variety of building types and encourage pedestrian traffic. Such typical block dimensions range between 300’ – 500’ on a block face and do not exceed 750’ on any single block face. Single blocks shall not exceed a total perimeter distance of 2,500’. 6. Proper Building Placement. Building types of like scale, massing, and uses shall face one another on a given street. To provide a harmonious transition, differing building types may be placed back-to-back on a single block. The primary entrance of every building shall directly face a street, a square, a park, a plaza, or a green. 7. Street Network. Neighborhoods shall have an interconnected network of public streets designed to balance the needs of all users, including pedestrians, bicyclists and motor vehicles. A hierarchy of streets shall be provided in the neighborhood so that larger streets accommodate larger buildings and wider sidewalks while smaller streets have smaller buildings and sidewalks. Streets and buildings shall be designed so the building height facing the street is proportional to the width of the street. Alleys are required in the mixed use areas of the neighborhood to provide access for rear-loaded parking, municipal Page 19 of 456 Project Name: The Club at Indrio Creek File No.: PD-2510-000058 Page 10 of 42 services, and loading and unloading of goods, which allows the street to be more safely used by pedestrians and bicyclists by reducing conflicts with vehicles. Alleys are required for townhouse development. In residential areas, alleys are encouraged, but not required, to accommodate parking and to provide private entrances and parking for rental units located behind single-family homes. Where alleys are used to provide rear access, buildings shall have secondary entrances, lighting and sufficient window openings to provide natural surveillance. 8. Mix of Uses. Neighborhoods shall support varying amounts of mixed use located within the appropriate area of the Transect within suitable building types. Different neighborhoods have diverse characters, which support varying amounts of mixed use; however, every neighborhood should support residential uses, a civic site, and at least one Local Store. 9. Countryside. A significant amount of Open Space is designated for the Countryside as an integral component of the settlement pattern to a) support and enhance the rural character; b) preserve and restore native habitats; c) provide opportunities for sustained agriculture; and d) help mitigate the biological and ecological impacts of new development. Policy 11.1.5.8 - Transition Between Neighborhood and Countryside. The neighborhood shall be separated from the Countryside and the Flow Way System by a public right-of-way that can take the form of an avenue, street, path or trail. This right-of-way shall be fully disclosed and maintained as a public right of way and shall be constructed concurrently with the development. The Proposed Preliminary Regulating Plan is presented as Exhibit 5. The enumeration of the various allocations of the land are summarized in Tables 1, 2 and 3. Page 20 of 456 Project Name: The Club at Indrio Creek File No.: PD-2510-000058 Page 11 of 42 Exhibit 5. The Club at Indrio Creek Preliminary Regulating Plan LEGEND = single family lots = townhome lots = lakes and parks = civic building lots = flow way = Proposed Restored/Created Native Habitat Page 21 of 456 Project Name: The Club at Indrio Creek File No.: PD-2510-000058 Page 12 of 42 Table 1. The Club at Indrio Creek Rights-of-way Table 2. Proposed Residential Development Summary As discussed throughout this staff report, the proposed Preliminary Regulating Plan for the Club at Indrio Creek incorporates several elements of the Towns, Villages and Countryside policy framework, including multiple residential building types, civic sites, open space areas, a flow-way system, extension of public utilities, and construction of part of the planned TVC roadway network. However, certain aspects raise questions regarding consistency with specific Comprehensive Plan policies and Land Development Code standards applicable to Planned Towns and Villages. The principal unresolved issues concern external and internal street connectivity, block dimensions, street and alley design, the mix of uses, Countryside and restored-habitat designations, density multiplier calculations, and workforce housing. Page 22 of 456 Project Name: The Club at Indrio Creek File No.: PD-2510-000058 Page 13 of 42 STREET NETWORK, CONNECTIVITY, and DESIGN As provided in the Comprehensive Plan and the LDC, street connectivity and street design are foundational components in the TVC due to the dominant impact it has on the convenience of day-to-day life and walkability.1 1. Connection to External Street Network The subject site is +/- 850 feet south of Indrio Road via Seminole Road and +/- 813 ft. via Emerson Avenue. Neither of these roads meets County’s standards. The Applicant has proposed to construct Emerson Avenue to county-standards within an 80-ft. right-of-way, consistent with the County Right-of-Way Protection Plan and TVC Future Street Network Plan, from Indrio Rd. to the project neighborhood entrance. The proposed section includes 12-ft. travel lanes, a 6-ft sidewalk along the eastern side, and a 5-ft. bike lane on the west side. While the Traffic Impact Report states that the construction of Emerson Avenue will include a 235-ft southbound left-turn lane at the project entrance, the submitted roadway plans do not provide that left turn lane. The Preliminary Development Plan and roadway plans should be revised to consistently identify all proposed and required improvements. The Club at Indrio Creek proposes to construct an important segment of the TVC future Street network. The proposed “Spine Road” connecting Seminole Road and Emerson Avenue is the equivalent of the new E-W Road A. However, the submitted plan limits the connection to Seminole Road to emergency access. As a result, all trips from the proposed 375 dwellings will be limited to one access to and from the site onto Emerson Avenue. While the Traffic Impact Report (TIR) for the proposed Village assumed 408 dwellings (more than now proposed), the TIR projected 3,200 daily trips, 230 AM Peak Hour trips and 293 PM Peak Hour Trips all of which would be limited to one point onto Emerson Avenue. 1 Professional Texts, such as Planning and Urban Design Standards and 21st Century Land Development Code published by the American Planning Association; New Urbanism Best Practices Guide published by New Urban News Publications; Great Streets, published by MIT Press; Street Design – The Secret to Great Cities and Towns published by Wiley, devote substantive attention to the importance of good street design for a good civic life and connectivity for convenience and sustainability and provide multitudes of examples of the types of streets the TVC Comprehensive Plan Element and the LDC seek to achieve. Page 23 of 456 Project Name: The Club at Indrio Creek File No.: PD-2510-000058 Page 14 of 42 Exhibit 6. Northern boundary of subject site and proximity to Indrio Road Figure 4-12 of the LDC (also Figure 3-15 in the Comprehensive Plan) provides the 2030 Street Network for the TVC and is provided as Exhibit 7. Exhibit 7. 2030 Street Network for the TVC The Club at Indrio Creek proposes to construct an important segment of the TVC future Street network. The proposed “Spine Road” connecting Seminole Road and Emerson Avenue is the equivalent of the new E-W Road A. However, it proposes that this new road Approx. location of Subject Site +/ - 8 1 3 f t . +/ - 8 5 0 f t . Page 24 of 456 Project Name: The Club at Indrio Creek File No.: PD-2510-000058 Page 15 of 42 will not be open to traffic from Seminole Road and is to be reserved for Emergency Access only. All trips from the proposed 375 dwellings will be limited to one access to and from the site onto Emerson Avenue. While the Traffic Impact Report (TIR) for the proposed Village assumed 408 dwellings (more than now proposed), the TIR projected 3,200 daily trips, 230 AM Peak Hour trips and 293 PM Peak Hour Trips all of which would be limited to one point onto Emerson Avenue. The Club at Indrio Creek proposes to construct Emerson Avenue for approximately 1,000 feet from Indrio Road, including a 235-ft. southbound left turn lane. The distance between Emerson Avenue and Seminole Road is just under one-half mile. Staff finds that the current plan does not demonstrate compliance with the TVC street network requirements. The following revisions and additional information are required: 1. A vehicular connection is needed to Seminole Road for consistency with the goal of the TVC to provide a street network with a one-quarter to one-half mile street grid. 2. The connection to Seminole Road will be approximately 1,000 feet in length and may require a proportionate share contribution to improvements to Seminole or improvements to the road, as determined after further consultation with the County Engineer. Limiting that Seminole Road to emergency access only is inconsistent with the intent of the Comp. Plan and LDC regarding the street network. 3. Provision for future street connectivity to the land to the south is required for compliance with the TVC Comprehensive Plan Policies and the LDC. 4. The E-W Road to be constructed as the spine road must be constructed to Seminole Road. The Preliminary Regulating Plan appears to indicate that the road will stop short of that connection. These improvements are needed for compliance with the following: Comp. Plan Policy 11.1.4.2, provides that “Neighborhoods shall have an interconnected network of public streets designed to balance the needs of all users, including pedestrians, bicyclists and motor vehicles. A hierarchy of streets shall be provided in the neighborhood so that larger streets accommodate larger buildings and wider sidewalks while smaller streets have smaller buildings and sidewalks.” Comp. Plan Policy 11.1.9.1, Sustainable Transportation, provides in relevant part, “Vehicular trips shall be reduced through a combination of the following . . . Provision of an interconnected street network designed for pedestrians, cyclists, the automobile and transit.” Comp. Plan Policy 11.1.9.6 - Internal Street Network. Neighborhoods shall construct interconnected networks of public streets in a predictable block pattern Page 25 of 456 Project Name: The Club at Indrio Creek File No.: PD-2510-000058 Page 16 of 42 that encourages walking, reduces the number and length of automobile trips, provides multiple circulation routes, and conserves energy. Comp. Plan Policy 11.1.9.7 - Interconnected Neighborhoods. The transportation system shall be designed so that multiple streets, bicycle paths and sidewalks continue into adjacent neighborhoods and developments to facilitate convenient movement and disperse traffic throughout the local network. Connections to existing or future collectors shall be provided at approximately one quarter mile intervals. Dead-end streets are prohibited, except when necessary at the edge of development to provide stub outs for future connections to adjacent, undeveloped properties. LDC 3.01.03.EE.2.k., street design network, “Street stubs must be provided to adjacent undeveloped land to ensure an integrated street network is achieved over time, except where the adjacent land is being designated as Countryside through the PTV approval.” Exhibit 8. Indrio Creek Regulating Plan emphasizing access to external streets and neighboring properties Page 26 of 456 Project Name: The Club at Indrio Creek File No.: PD-2510-000058 Page 17 of 42 2. Internal Street Connectivity Comp. Plan Policy 11.1.4.2 .5 provides as follows: “Walkable Blocks. Blocks shall be scaled to accommodate a variety of building types and encourage pedestrian traffic. Such typical block dimensions range between 300 ft. – 500 ft. on a block face and do not exceed 750 ft. on any single block face. Single blocks shall not exceed a total perimeter distance of 2,500 ft.” Similarly, LDC Section 3.01.03.2.k. provides as follows: The average perimeter of all blocks within a neighborhood may not exceed 1,500 feet. The maximum perimeter of any block may not exceed 2,400 feet. The portion of any block between intersecting streets may not exceed 500 feet without a publicly dedicated pedestrian sidewalk or trail providing access to another street. Smaller block sizes are encouraged to promote walkability. An applicant may propose minor modifications to these block size standards during the PTV rezoning process; the BOCC shall decide whether to accept, modify, or reject such modifications during the approval process based on consistency with the goals, objectives and policies of the TVC Element and the applicable site plan approval standards in Ch. XI of this Code. Exhibit 9. Applicant’s Block Dimension illustration Page 27 of 456 Project Name: The Club at Indrio Creek File No.: PD-2510-000058 Page 18 of 42 The Applicant measures the proposed blocks as groups of two townhouse buildings separated by pedestrian paths, regardless of whether the areas are bound by intersecting streets. Using that methodology, the Applicant calculates an average block perimeter of 865 feet and a maximum block perimeter of 1,217 feet. While the LDC does not define “block,” The 21st Century Land Development Code, published by The American Planning Association in 2008, defines block as “a tract of land bounded by streets, or by a combination of streets and public parks, cemeteries, railroad rights-of-way, shorelines of waterways, or boundary lines of local government.” Additionally, the code provision quoted above references, “The portion of any block between intersecting streets.” The Applicant asserts that because a pedestrian path will be provided between townhouse buildings, the distance between each pedestrian path constitutes a block. Staff does not agree that a pedestrian path between townhouse buildings independently creates a new block for purposes of the LDC block-perimeter standards. The LDC refers to the portion of a block “between intersecting streets,” which indicates that blocks are generally formed by intersecting streets or comparable physical boundaries. Although a pedestrian connection may be required where the distance between intersecting streets exceeds 500 feet, the pedestrian connection does not necessarily divide the underlying street-bounded area into separate blocks. The LDC allows an Applicant to request minor modifications to the block-size standards during the PTV rezoning process. Before the Board can evaluate any requested modification, the Applicant must submit block-perimeter calculations using a methodology consistent with the LDC, identify each block that does not meet the stated standards, quantify the requested deviation, and explain how the resulting block configuration remains consistent with the goals, objectives, and policies of the TVC Element. Staff acknowledges that strict compliance with the block-perimeter standards may be difficult on this site and that a reasonable modification could be consistent with the TVC Element. However, the current calculations do not provide an adequate basis for evaluating or approving a modification. Staff’s approximate measurement of the three largest blocks, indicated by pink perimeters, proposed for Indrio Creek are presented in Exhibit 11. Page 28 of 456 Project Name: The Club at Indrio Creek File No.: PD-2510-000058 Page 19 of 42 Exhibit 10. Block Perimeter. One last point on internal street connectivity, LDC 3.01.03.EE.2.k. provides, “Cul-de- sacs are not permitted except where physical conditions such as freeways provide no practical alternatives for connection for through traffic. Canals may or may not be physical barriers; appropriate crossings will be considered at the time of PTV approval.” The proposed plan provides for one dead-end street. While the proposed turn around would be required to be designed as a cul-de-sac, whether in the TVC or outside the TVC, whether that proposed dead end violates this section of code warrants consideration. 3. Street Design The Comp. Plan requires alleys for townhomes. See, Comp. Plan Policy 11.1.4.2.7. In several places the LDC implies that alleys are required for townhomes, but it does not so state in a simple declarative sentence. One must parse together different sections of code and read them as a whole. For example, LDC 3.01.03.EE.2.f., Building Form and Placement, provides for the off-street parking to be located in the rear of the townhouse lot and for the primary entrance to be near the street and on-street parking. Parking can only be in the rear if there is a rear alley. A = 3,771 ft. B = 3,436 ft. C = 2,909 ft. Page 29 of 456 Project Name: The Club at Indrio Creek File No.: PD-2510-000058 Page 20 of 42 Exhibit 11. Building Form and Placement for Townhomes per the LDC The proposed Club at Indrio Creek provides alleys to serve the townhomes. The question that arises in the context of the proposed Club at Indrio Creek is whether an alley may serve as the only vehicular access to the dwelling. As defined in the APA’s 21st Century Land Development Code, an alley “a public or private right-of-way primarily designed to provide secondary access to the side or rear of those properties whose principal frontage is on some other street.” Staff believes this definition is consistent with the common understanding of the function of an alley, that the building has frontage on another street. However, the definition of alley in the LDC--“a right-of-way privately or publicly owned, primarily for service access to the back or sides of properties—makes no reference to frontage on another street. Additionally, LDC 3.01.03.EE.2.g., expressly provides that Page 30 of 456 Project Name: The Club at Indrio Creek File No.: PD-2510-000058 Page 21 of 42 each building must have an entrance facing a street or public open space, which indicates that the proposed arrangement for the townhomes might be acceptable. Further, LDC 3.01.03.EE.2.g. provides “A continuous network of rear and side alleys and/or lanes is desirable to serve as the primary means of vehicular ingress to individual lots.” Though staff believes this sentence read alone to conclude that access via an alley without another street is taking it out of context, the plain words are what they are. However, other code provisions regarding alleys, e.g., that they are required in the Center and Core transect zones, but optional or desirable in other transect zones implies alleys are intended to be secondary access not primary access. Additionally, the streetscape standards provided in LDC 3.01.03.EE.2.j. treat alleys as an element of the street standards, just as the street edge (curb or swale), planting strip, pedestrian accommodation (trail or sidewalk) are a street standard, as distinguished from a type of street. The alleys providing access to the majority of the townhomes in Indrio Creek are not secondary access but the only street access. The proposed townhomes front a sidewalk and common open space. The exceptions are the townhomes that front the Main Spine Road. For these +/- 53 townhomes fronting the Main Street, the alley provides access to the off-street parking located in the rear. See Exhibits 12 and 13. This proposed arrangement is inconsistent with LDC Section 4.04.04.F., TVC Specific Standards for Residential Driveways and Garages, “In residential neighborhoods, an important walkability consideration is whether driveways, cars and on-street parking dominate the streetscape or continuous, wide, uninterrupted sidewalks and healthy street trees are provided.” While having the townhomes front on common open space may work well, the preliminary development plan has many townhomes front on land designated to become restored or created native habitat. Created and restored native habitat requires “only native species in the canopy, understory, and groundcover in proportions similar to those found in representative naturally occurring plant communities in St. Lucie County.” It may be able to accommodate a walking path for passive recreation such as walking or jogging but it is incompatible with active recreation or general play by children. It is not clear that created and restored habitat is appropriate right up to the fronts of the dwellings. It may pose a fire risk and it will be difficult to sustain the habitat in such close proximity to dwellings. The Preliminary Development Plan even shows it on the private lot side of the sidewalk. Finally, the proposed sidewalk along the front of the homes are only 4 feet wide. Six feet is the minimum width of sidewalks in the TVC. See LDC 3.01.03.EE.2.j. Page 31 of 456 Project Name: The Club at Indrio Creek File No.: PD-2510-000058 Page 22 of 42 Exhibit 12. Typical Townhome Lot Layout Page 32 of 456 Project Name: The Club at Indrio Creek File No.: PD-2510-000058 Page 23 of 42 Finally, the LDC calls for an Edge Street to separate the neighborhood from the Countryside. Edge Streets are single-loaded, having private lots on one side while providing visual and physical access to the Countryside on the other. The Club at Indrio Creek instead lines most of the proposed Countryside by private dwellings. As discussed elsewhere in this report, the proposed plan locates restored/created habitat directly against the private lot lines. Providing an Edge Street adjacent to the proposed restored/created native habitat is one way to provide the separation that seems necessary. Exhibit 14. Edge Street. Alley Proposed Restored/Created Native Habitat Rear of home Front of Home Exhibit 13. Typical Townhome Lot proposed by Applicant Page 33 of 456 Project Name: The Club at Indrio Creek File No.: PD-2510-000058 Page 24 of 42 A. Residential Density, Transferable Development Credits and Density Multipliers A fundamental component of the Towns, Villages and Countryside Future Land Use framework is that the residential density allowed by the future land use category on the property prior to the adoption of the TVC remains in place and is documented in the Transferable Development Value Map. Most of the +/- 13,600 acres within the TVC previously had the AG-1 (Agricultural-1) Future Land Use category and now have a base residential density of 1 DU/A. The companion feature of the TVC is that the base density can be increased on parcels through the transfer of development rights from one parcel of land to another parcel. Additionally, to encourage certain preferred uses, such as Countryside or Restored/Created Native Habitat, a density multiplier is available. In the TVC “Countryside” includes the flow way, agricultural production, as well as community recreational areas and parks, if certain criteria are met. The land (+/- 126 acres) on which the Club at Indrio Creek is proposed has a base residential density of 2 DU/A on +/- 109 acres and a base residential density of 1 DU/A on +/- 18 acres. The applicant proposes to achieve density of 3 DU/A through the use of transferred development rights from Countryside and Created/Restored Native Habitat. Another fundamental aspect of development of a Planned Town or Village is that the code establishes a minimum density of 5 DU/A for the New Developable Area (Total Site less Countryside). The applicant must demonstrate compliance with this minimum independently of the gross-density calculation. Table 4 quantifies the topics discussed above, as applied to the Club at Indrio Creek— base residential density plus the density multipliers available for certain preferred uses. Table 3. Calculation of the number of dwelling units attainable by the Club at Indrio Creek Staff agrees with the mechanics of the Applicant’s calculations. The subject on which there has not yet been a meeting of the minds is regarding what land area constitutes Page 34 of 456 Project Name: The Club at Indrio Creek File No.: PD-2510-000058 Page 25 of 42 Restored/Created Native Habitat that is therefore eligible for the 2.5 density multiplier and which land areas qualify as Countryside that is eligible for the 1.75 density multiplier. LDC 3.01.03.EE.2.o, Open Space and Countryside Standards, in sub-section (5) establishes the following standards for restored and preserved native habitat: i. Restored habitats are at least twenty-five (25) acres in size; ii. Restored habitats are connected to the greatest extent possible to existing preserved native habitat or preserved environmentally significant land or to the Flow Way System; iii. Restored habitats must include multiple upland and wetland habitat types consistent with habitat types that can be supported by the existing soil types and the proposed hydrology for the site; iv. Restored habitats include only native species in the canopy, understory, and groundcover in proportions similar to those found in representative naturally occurring plant communities in St. Lucie County; and v. Shallow marsh systems are encouraged. Deep water habitat and the required littoral zone and upland buffer habitat (Section 3.01.03.EE.2.p(4)(ii)and (iii)) are not eligible for restoration credit, but shallow marsh acreage beyond the requirements may be eligible for full restoration credit. vi. Proposals that request an increased multiplier for transferable development rights based on creating or restoring natural habitats from former agricultural lands must be accompanied by a restoration and management plan. The Board of County Commissioners will decide whether to accept or modify such plans during the PTV approval process. The restoration and management plan must include the following: 1) Identifies the area to be restored; 2) Identifies the strategy that will be employed to restore the land; 3) Provides an acceptable time table for completion of the restoration; 4) Identifies measures that will be used to evaluate the success of the restoration, including the density and distribution of species; and 5) Includes a funding strategy for monitoring and maintaining the habitat, including the ongoing maintenance and removal of exotic vegetation. The dark green areas on the proposed Preliminary Regulating Plan identify 25.36 acres (17.58 acres with base density of 2 DU/A area and 7.78 acres with base density of 1 DU/A area) as being dedicated to proposed and restored native habitat. Two elements of the Applicant’s proposal prevent recommendation of approval regarding the component of the Plan. 1. No restoration and management plan has been submitted. 2. Some areas identified as restored and preserved habitat are two small to qualify. Page 35 of 456 Project Name: The Club at Indrio Creek File No.: PD-2510-000058 Page 26 of 42 The TVC code does not expressly provide minimal dimensional criteria to qualify as restored and preserved habitat. However, LDC 3.01.03.EE.2.s., Landscaping and Natural Features, expressly provides that development in the TVC must comply with Chapter VI, Resource Protection Standards. LDC 6.00.05.D.3.b.1.c., applicable to native upland preservation provided as a form of tree mitigation, provides standards: “Habitat preservation areas shall minimize edge to interior ratio, and shall have no minimum dimension less than one hundred (100) feet, and shall not exceed a length to width ratio of three to one (3:1) unless exceeding this ratio allows for superior connections with adjacent parcels or other environmental benefits.” Additionally, LDC 3.01.03.EE.2.p. expressly provides that the flow way littoral and the flow way native upland edge vegetation do not qualify for the 2.5 multiplier as restored and preserved Native Habitat. Staff calculations identify 10.86 acres within the 2 DU/A area and 4.26 acres in the 1 DUA area meet the dimensional standard to qualify as restored and preserved habitat. These areas are identified as A through F on Exhibit 15 and total approximately 10 acres less than that identified by the Applicant. The result of that 10-acre difference is 42 units, before consideration of whether the land area excluded by staff may qualify as Countryside and be eligible for be eligible for the 1.75 multiplier. If the land area that does not qualify as native upland habitat, instead qualifies as Countryside, the reduction in dwelling units is reduced to only +/-10 units. [Staff notes an important caveat. AS discussed previously, some of the proposed restored native habitat includes sidewalks and is proposed to be located right -up against the townhome lots. This does not appear to be an appropriate or sustainable arrangement. Therefore, the land area staff believes can qualify as restored habitat will likely decrease. The question remaining is to what extent staff should recommend additional flexibility regarding these minimum standards—the 100– ft minimum dimension and the 1:3 maximum width-to-length ratio. For example, some of the proposed perimeter landscape buffers are adjacent to proposed flow way upland buffer and flow way littorals. If the combined width of those different elements is equal to or exceeds 100 feet, should that portion of the buffer, that is not the flow way littoral or flow way native upland edge vegetation, should it count as restored and preserved native habitat? Staff would appreciate receiving input from the Planning and Zoning Commission on this question. Page 36 of 456 Project Name: The Club at Indrio Creek File No.: PD-2510-000058 Page 27 of 42 Exhibit 15. Preliminary Regulating Plan and proposed Native Habitat Restoration Areas C. Flow Way Development of a Village must provide a Flow Way. The natural resources standards applicable to the flow way are more ambitious than the requirements applicable to stormwater management areas outside of the TVC. Pursuant to LDC 3.01.03.EE.2.p., flow way standards include: Page 37 of 456 Project Name: The Club at Indrio Creek File No.: PD-2510-000058 Page 28 of 42 1. A pedestrian and bicycle trail system must be provided and maintained along at least one side of the system.2 2. A vegetated and functional littoral zone shall be established as part of the Flow Way System. (a) As a minimum, 20 sq. ft. of vegetated littoral zone per linear foot of shoreline shall be established as part of the water management system. (b) This area of vegetated littoral zone habitat shall be located such that no less than 50% of the total shoreline of the Flow Way System is buffered by littoral zone habitat. (c) Littoral zone habitat shall be a minimum width of 20 feet and a minimum of 25% of the shoreline shall be designed as a wide littoral zone habitat a minimum of 60 feet in width. (d) Average water depth over the littoral shelf should range between 2 to 18 inches at the control elevation. The littoral shelf should be contoured to create areas with shallow depressions that should dry down or retain 2 to 6 inches of water when the water level is one foot below the control elevation (see Figure 3-15), except for points of inflow which may be deeper. (e) A native upland vegetative buffer shall be provided and maintained around the Flow Way System. The habitat may consist of preserved or planted vegetation, but shall include canopy, understory, and ground cover species only. The edge habitat shall begin at the upland limit of the Flow Way System. As a minimum, 20 sq. ft. of edge habitat shall be provided for each linear foot of shoreline. This upland edge habitat shall be located such that no less than 50% of the total shoreline is buffered by a minimum width of 20 feet of upland habitat. The level of detail provided for the Preliminary Development Plan is insufficient to confirm compliance with some flow way standards, but the proposed typicals for the littoral zones and native upland buffers around the lakes do not comply with the applicable standards and must be revised. B. Workforce Housing Planned Towns and Villages are required to provide workforce housing as part of the new neighborhoods. The requirements are summarized in Table 5. 2 Page 38 of 456 Project Name: The Club at Indrio Creek File No.: PD-2510-000058 Page 29 of 42 Table 4. Summary of Permitted Density and Workforce Housing Requirements in the PTV Zoning District Parameter or Measure Standard Minimum % of total dwelling units 8% 4 % affordable to households with 80% to 100% of AMI and 4% affordable to households with 100 to 120% of AMI. Period of Affordability 8 years Location of WF Units Dispersed throughout the neighborhood Tenure Rental and home-owner units in same proportion as market-rate units Size of unit Mix of # of bedrooms must be proportionate to mix of # of bedrooms in market rate units. Housing Type Not specified Phasing/Timing Approximately the same schedule as market-rate units C. LOT AND DWELLING TYPES The Club at Indrio Creek proposes two differently sized detached single-family lots, a Villas Lot and two townhome lots. The “Lot Typicals” for are summarized in Table 6 and Exhibits 8A, 8B and 8C. The front setbacks for the proposed Villas do not appear to comply with comply with LDC 4.04.04.F. which requires the garage to be recessed at least 10 feet from the front façade of the dwelling. The 10-ft. garage setback may be measured from the front porch. Additionally staff notes, regarding the 10-ft rear setback for the Villas, a 3- foot rear setback is proposed when the lot adjoins a lake. Setbacks from the property line have been an essential component of zoning codes since the first was adopted by New York City in about 1916, in order to reduce risk from fire and disease and increase light and airflow to the dwellings and privacy for the inhabitants. The proposed 10-ft. minimum rear yard is less than the minimum 15-ft. rear yard required in the County’s conventional zoning districts. The County’s conventional zoning code permits grade level accessory structures to be built to the rear or side lots lines, but any accessory structure more than 30-inches above grade must comply with the otherwise applicable setback. Similarly, the proposed 5-ft side setbacks may be considered narrow for detached Page 39 of 456 Project Name: The Club at Indrio Creek File No.: PD-2510-000058 Page 30 of 42 single-family dwellings. For example, when the air conditioning unit and possible pool equipment is located there, if the side yard is fenced, it is difficult to even get a lawn mower through. Increasingly, the Board of County Commissioners is expressing preference for setbacks that provide for more space, and air flow between dwellings. Additionally, staff notes the requirement for single-family and two-family lots that one tree be planted for each 2,500 sq. ft. of lot area. Very narrow side and rear setbacks leave not room for the planting of those trees. The Villas lots is also marked with a 10-ft utility easement across the front, further restricting the lot area where a tree can be planted. Table 5. Detached Single-Family Residential Lots Lot Width Lot Depth Lot Area in Sq. Ft. Front Side Rear Townhome 32 90 2880 Townhome 22 90 1980 Villas 25 120 3000 22 5 10 Single Family 50 120 6000 22 for garage; 6 for porch 5 10 Single Family 60 120 7,200 22 for garage; 6 for porch 5 10 The TVC permits an Accessory Dwelling Unit (ADU) that does not count towards density. ADUs are desirable because they provide a mechanism to scatter rental housing in an otherwise detached single-family neighborhood without drastically impacting the feel of the neighborhood as being single-family. ADUs can accommodate extended family, provide an income stream to the homeowner, or allow an elderly person who needs assistance to remain in his or her own home. Inquiries by property owners about the ability to add an ADU to accommodate a family member is a frequent question the County’s Planners of the Day receive to which we must respond that it is not possible. The proposed Indrio Creek lots likely preclude inclusion of an ADU. The future owner of a single-family lot may be able to provide a small ADU as the second floor of a garage (so long as the homeowner covenants and restrictions do not prohibit it). Small ADUs might also be accommodated as the second floor of the rear-loaded garages serving the townhouses, if Page 40 of 456 Project Name: The Club at Indrio Creek File No.: PD-2510-000058 Page 31 of 42 planned for from the start. Depending on the size of the dwellings constructed on the lots and the interests of the lot buyers, if additional flexibility is built into the building and parking configuration on the lots, future owners might be able to accommodate an accessory dwelling unit. Additionally, no lots are likely to be able to accommodate a detached garage or workshop. That completes the discussion of the first standard of review for the proposed Preliminary Development Plan—whether the proposed plan complies with the Comprehensive Plan and the Land Development Code. Now the next standards will be reviewed. B. Effect on Adjacent Properties “1. The proposed building or use will not have an undue adverse effect upon nearby property, the character of the neighborhood, traffic conditions, parking, utility facilities, and other matters affecting the public health, safety, and general welfare. 2. All reasonable steps have been taken to minimize any adverse effect of the proposed building or use on the immediate vicinity through building design, site design, landscaping, and screening. 3. The proposed building or use will be constructed, arranged, and operated so as not to interfere with the development and use of neighboring property, in accordance with applicable district regulations.” The proposed Club at Indrio Creek with the necessary off-site infrastructure improvements, is not expected to have an undue adverse effect upon nearby property. The development will increase the amount of people, housing and traffic in this corner of the county, but perimeter landscaping, . . . The extension of regional water and wastewater lines to this currently unserved area and the improvement of Emerson and Seminole may encourage the urbanization of other nearby land. However, the County Comp. Plan and LDC expressly provide for this type of development C. Adequacy of Public Facilities. 1. Water and Wastewater The subject property is within the Urban Services Boundary and the St. Lucie County Utility Services Area. A 16-inch potable water line and a 16-inch sanitary sewer force main exist on the northwest corner of Emerson Avenue and Indrio Road. The adopted Level of Services for potable water for residential land use is 110 gallons per capita per day (g/c/d) and for wastewater is 110 g/pd. Assuming the dwellings in Indrio Groves are occupied by the median household size in St. Lucie County of 2.50, 375 households will demand 103,125 gallons of water per day and require treatment capacity for the same amount of wastewater per day. Page 41 of 456 Project Name: The Club at Indrio Creek File No.: PD-2510-000058 Page 32 of 42 The current design capacity of the Holiday Pines water plant is 288,000 gallons per day (gpd) with current daily flows of 225,000 gpd. Additional capacity is available from the interconnect with the Fort Pierce Utilities Authority (FPUA). The current design capacity of the Holiday Pines wastewater treatment plant is 600,000 gallons per day (gpd) and the current daily flows to the plant are 150,000 gpd. The District is in the design and permitting phase to add 600,000 gpd of additional wastewater treatment capacity for the Holiday Pines Plant. Finally, additional wastewater capacity is available to St. Lucie County Utilities via an interconnect with FPUA facilities. Expansion of the County’s capacity to produce and distribute potable water and to collect and treat sanitary wastewater for the North County Planning Area are acknowledged in the County’s 5-Year Capital Improvement Program. Future expenditures of $43,6544,619 are anticipated for the new 2 million gpd water plant on Taylor Dairy Road and future expenditures of $10,000,000 are anticipated to expand the Holiday Pines Wastewater Treatment Plant 2. Fire Protection and Emergency Medical Services Fire protection and Emergency Medical Services are available via dispatch from St. Lucie County Fire District Station 7, located at 4900 Fort Pierce Blvd., less than one mile northeast of the subject site. Planning is underway for Station No. 7 to be relocated to Taylor Dairy Road, south of Indrio Road. That location is less than two miles away. Currently the County does not have an adopted Level of Service (LOS) for emergency response, in terms of, for example, average response time within the Urban Services Boundary or average response time outside the USB. St. Lucie County’s emergency medical needs are largely fulfilled by three area hospitals: Lawnwood Regional Medical Center and Heart Institute with approximate automobile travel times from the subject site being about 20 minutes. Additionally, given the North County location of the Indrio Groves site, Indian River Memorial Hospital, Inc. is also an option, also with average automobile travel times in the range of 20 to 30 minutes. The residential development proposed by Indrio Groves will increase demand for fire protection, public safety, and emergency medical services and facilities. 3. Transportation The availability and limitations of the surrounding road network were discussed in detail previously. Nonetheless, the Applicant’s Transportation Impact Report finds that the traffic from the project will not cause a failure in the level of service (LOS) on the nearby roadways. That TIR has been accepted by the County’s Third-Party Reviewer. Page 42 of 456 Project Name: The Club at Indrio Creek File No.: PD-2510-000058 Page 33 of 42 St. Lucie County has not yet adopted a LOS for transit service and no transit services currently serve the area. Despite its remote location, staff included as a Condition of Approval that potential locations for transit stops be identified on Final Site Plans. D. Adequacy of Fire Protection. Addressed above under Adequate Public facilities. E. Adequacy of School Facilities. With 375 projected dwelling units, the proposed Indrio Creek will demand school capacity. The ultimate number of school students originating from the development will depend in part on the ultimate mix of unit types and their respective number of bedrooms. The St. Lucie County School District facility planning methodology assumes each single-family dwelling will generate 0.405 students and each multifamily dwelling (including townhouses) will generate 0.207 students (70% K-8 and 30% high school). Therefore, Indrio Creek can be expected to generate some 72 K-8 students and 31 high school students at build out. Lakewood Elementary School (Pre-K through 5th grade) is the closest elementary school, located within one-half mile of the subject site. As of April of 2025, Lakewood Park Elementary School had capacity to enroll an additional 313 students (students from less than 1,000 dwellings). The approved Preliminary Development Plan for the Indrio and I-95 PTV Zoning District has also allocated land area for a future K-8 school site, on Johnston Road. At this time, when that school might be constructed is completely unknown. Existing High Schools are further away. The distance to Westwood Academy exceeds +/- 6.2 miles and can be expected to be a ten to 15 minute drive, according to Google Maps. Lincoln Park Academy is +/- 8 miles away and should take about 15 minutes via a private automobile. Fort Pierce Central High School is 11 or 12 miles away and the one-drive should be about 25 minutes. It is worth noting that there is no “second bus” or “activity bus” from the St. Lucie County High Schools for students who participate in after-school sports or other extracurricular activities, such as student government, service clubs, band or theater. If a student remains after the regular school day, he or she must find his or her own way home. F. Environmental Impact The St. Lucie County Environmental Resources Department (ERD) has reviewed the application materials including the Applicant’s Environmental Assessment prepared by Loxahatchee Holdings, LP dated August 2025, prepared to support the request to re-zone and the Preliminary Development Plan. The review by ERD is underway. It has noted Page 43 of 456 Project Name: The Club at Indrio Creek File No.: PD-2510-000058 Page 34 of 42 the lack of compliance with landscaping, flow way and native habitat restoration standards. AMENDMENT OF ZONING ATLAS STANDARDS OF REVIEW SET FORTH IN LAND DEVELOPMENT CODE SECTION 11.06.03 Section 11.06.03 of the St. Lucie County Land Development Code (LDC) establishes the standards for reviewing proposed amendments to the Zoning Atlas. In reviewing such an application, the Planning and Zoning Commission and the Board of County Commissioners shall consider the following factors: A. Whether the proposed rezoning conflicts with any applicable portions of the St. Lucie County Land Development Code: This factor was addressed in the context of the review of the proposed Preliminary Development Plan, earlier in the staff report. B. Whether the proposed amendment is consistent with all elements of the St. Lucie County Comprehensive Plan: This factor was largely addressed earlier in the report in the context of the consistency between the proposed Preliminary Development Plan and the Comprehensive Plan. C. Whether and the extent to which the proposed zoning is inconsistent with the existing and proposed land uses: The proposed Indrio Creek PTV Zoning District with a proposed 3 DU/A provides for substantially more intensity and density than the existing uses to the north, east, west and south. Across Emerson Avenue is outside the USB and should be expected, therefore to remain rural for a longer period into the future. However, the Comprehensive Plan and the LDC expressly provide for development of a Village inside the Urban Services Boundary. Additionally, the Plan largely locates the flow way, restored habitat and other countryside along the property boundaries which buffer adjacent properties. Page 44 of 456 Project Name: The Club at Indrio Creek File No.: PD-2510-000058 Page 35 of 42 Table 6. Future Land Use, Zoning and Existing Land Use on Adjacent Properties Location Future Land Use designation Zoning Districts Existing Land Use Subject Property TVC (up to 1 DU/A (partial) and up to 2 DU/A (partial)) AG-1 (Agricultural–1 DU/A) Agriculture North TVC (2 DU/A) AG-1 (1 DU/A) Agriculture and Estate Lot residential South TVC (Towns, Villages & Countryside) AG-1 Agriculture East TVC (Towns, Villages and Countryside) AG-1 Agriculture and Estate Lot residential Adja cent Parc els West TVC AG-1 Agriculture D. Whether there have been any changed conditions that require an amendment. No change has occurred that requires the rezoning. One change that has occurred and is occurring is the increased development interest and activity in the TVC. This increased activity also does not mandate the amendment of the Zoning Atlas but provides examples of other amendments to the Official Zoning Atlas that have been approved or are under review in the TVC. Table 11 summarizes development application activity in the TVC. Page 45 of 456 Project Name: The Club at Indrio Creek File No.: PD-2510-000058 Page 36 of 42 Table 7. Pending and Approved Development Projects in the TVC Project Name Application Type Project Description Status 1 Publix at Indrio Commons Major Site Plan Retail Center including 48,387 sq. ft. supermarket, 10,800 sq. ft. other retail, & 4,500 sq. ft. fast food. Approved in August 2019 2 Indrio & I-95 PTV (Planned Town or Village) Rezoning to PTV and Preliminary Development Plan Planned Village with 1,878 SF dwellings, 805 multi-family dwellings, 1,000,000 sq. ft. of commercial including 88,000 sq. ft. of retail, school, fire station, gas station, other civic sites, with associated amenities and infrastructure Approved 3 Indrio Woods Rezoning to PUD 274 apartments with associated amenities and infrastructure Approved 4 Indrio Woods Final Site Plan 229 multi-family units on 35.58 acres Approved 5 4540 N. Kings Hwy. Rezoning to PUD and Preliminary Development Plan 191 dwellings (detached single- family, townhouses and apartments) on 36.65 acres Approved 6 4540 N. Kings Hwy Final Site Plan 165 dwellings on 36.65 acres Under review 7 Bedner Farms Rezoning to PRW, Preliminary Development Plan & LDC Text Amendment Up to 1,090 single-family, townhouses and apartments, and 420,000 sq. ft. of commercial space Approved 8 Bedner Farms Commercial PRW Site Plan 420,000 SF of commercial Under review 9 Bedner Farms Northwest PRW Site Plan 305 single-family dwellings on 67 acres Approved 10 Bedner Farms East, Phase 1 PRW Site Plan 157 single-family and 154 townhouses on +/-45.15 acres Approved 11 2098 Johnston Rezoning to PUD 74 single-family lots on 41.18 acres Approved Page 46 of 456 Project Name: The Club at Indrio Creek File No.: PD-2510-000058 Page 37 of 42 Project Name Application Type Project Description Status 12 Alco Groves Mine CUP, Site Plan, & Mining Permit Mining of +/-311 acres for ten-year period Under review 13 Sexton Place Rezoning to PTV 505 dwellings on 235.49 acres Under review 14 Indrio Groves Rezoning to Hamlet PUD +/- 2,978 dwellings, school site, County Park, fire station site, etc. on 1,027.11 acres Tabled 15 SLC Water Plant Minor Site Plan County water treatment plant on 37.99 acres Approved 16 Indrio Crossings Rezoning to PR/W and extension of USB 85 dwellings and 323,223 sq. ft. of commercial on 85.29 acres Under Review 17 Rocking Horse Ranch Rezoning to PUD 160 dwellings on 159 acres Approved April 2021 18 Treasure Coast Land Ventures, IIC property Rezoning to PCS +/-77.6 acres Approved May 2008 19 Indrio 77, LLC property Rezoning to PCS +/-79 acres Approved Feb. 2008 20 Treasure Coast Auto Vault Major Site Plan +/-95,000 sq. ft. contractor trade and private warehouse space with 20,000 sq. ft. of covered parking Approved 21 Bhasin Industrial Major Site Plan +/-178,000 sq. ft. industrial warehouse Approved 22 Meadowood Phase 2 PUD Adjustment Forty-seven single-family homes, walking trails and conservation lands Approved 23 Cabo Rio Rezoning to PR/W 146-space RV Park with for condo-lot ownership with associated amenities and infrastructure Approved; under construction 24 Isram Hamlet PUD Rezoning to PUD 1,628 dwellings and 12 acres of commercial Under review Page 47 of 456 Project Name: The Club at Indrio Creek File No.: PD-2510-000058 Page 38 of 42 E. Whether and the extent to which the proposed amendment would result in demands on public facilities, and whether or to the extent to which the proposed amendment would exceed the capacity of such public facilities, including but not limited to transportation facilities, sewage facilities, water supply, parks, drainage, schools, solid waste, mass transit, and emergency medical facilities. The availability and demand created by the proposed rezoning on public facilities including water and wastewater, schools, fire and emergency response, discussed in depth in regard to the proposed Preliminary Development Plan. Parks, drainage, solid waste and public transit will be addressed here. 1. Parks The Comprehensive Plan Recreation Element strives to support an adequate and equitable distribution of parks, recreation, and open spaces throughout the county to provide a range of activities for residents and visitors. The St. Lucie County +/- 156 -acre Regional Park on Emerson Avenue is located about 2 miles north of the subject site The Comprehensive Plan Level of Service (LOS) standards for parks and recreation are as follows: • Community parks: 5.0 acres/1000 residents in unincorporated area; • Regional parks: 2.5 acres/1000 population county-wide; and • Resource-based parks: 21.2 acres/1000 population county-wide. Based on U.S. Census Bureau data for 2024, with average household size in St. Lucie County of 2.5 persons the residents of the Club at Indrio Creek will generate the need for +/-4.7 acres of community parks, 2.3 acres of Regional Parks, and 19.8 acres of Resource-based parks. 2. Drainage The Indrio Groves Hamlet proposes +/- 23 acres of flow way plus 2 additional lakes to receive and treat stormwater run-off before it is discharged to the FPFWCD Canal No. 6 in which it will ultimately flow to the Indian River Lagoon. The proposed drainage system will be required to meet the standards promulgated by St. Lucie County, SFWMD, and FFPWCD. Summary The St. Lucie County Concurrency requirements for public facilities and services as well as impact fees levied on new construction are intended to assure that adequate public facilities and services are available at the time those impacts are experienced and that the costs of the impacts of new development are born by the development. Further analysis will be required prior to Final Site Plan approval, accounting for timing of other nearby development and capital improvement schedules. Page 48 of 456 Project Name: The Club at Indrio Creek File No.: PD-2510-000058 Page 39 of 42 F. Whether and the extent which the proposed amendment would result in significant adverse impacts on the natural environment: The subject site was largely cleared long ago for agricultural production. See ERD Report included in agenda materials. G. Whether and the extent to which the proposed amendment would adversely affect property values in the area. The proposed zoning change is not anticipated to have an adverse impact on property values in the area. The re-zoning to PTV may contribute to a rise in real estate values in the area. H. Whether and the extent to which the proposed amendment would result in an orderly and logical development pattern specifically identifying any negative effects of such patterns. The proposed PTV can contribute to an orderly and logical pattern on the subject site and is reasonably consistent with the vision for a TVC Village, subject to resolution of the details on restoration of habiat and flow way standards. The proposed density is substantially higher than the existing density in the surrounding countryside. However, the land area is within the USB and reasonably proximate to existing water and wastewater lines, an elementary school and a supermarket. I. Whether the proposed amendment would conflict with the public interest and is in harmony with the purpose and intent of this Code. The proposed Zoning Atlas amendment would not conflict with the public interest and is generally in harmony with the purpose and intent of the St. Lucie County Land Development Code. J. Any other matters that may be deemed appropriate by the Planning and Zoning Commission or the Board of County Commissioners, in review and consideration of the proposed amendment. The Planning and Zoning Commission may raise other matters regarding this proposed amendment to the Official Zoning Atlas. SUMMARY OF ANALYSIS: Based upon the analysis contained in this report, the application materials for the proposed rezoning from AG-1 (Agricultural – 1) to the PTV (Planned Towns and Villages) and the Preliminary Regulating Plan do not demonstrate sufficient compliance with the St. Lucie County Comprehensive Plan and Land Development Code. Refinements to the proposed Preliminary Development Plan regarding external connectivity and off-site improvements to support the transportation demands generated by the project, are required for comprehensive consistency with adopted policy. Additionally, the input of the Planning and Zoning Page 49 of 456 Project Name: The Club at Indrio Creek File No.: PD-2510-000058 Page 40 of 42 Commission is sought regarding street design and eligibility for density multipliers for created and restored native habitat. COMMUNITY PARTICIPATION MEETING: The Applicant hosted a Community Meeting at the Summer Crush Vineyard on Johnston Road. It was attended by approximately 8 owners of nearby real property, the Applicant and County staff. PUBLIC NOTICE: In accordance with requirements in LDC Section 11.00.03., on July 3, 2026 notice of the public hearing was published in the St. Lucie News Tribune, on July 1, 2026, notice was mailed to owners of real property located within 500 feet of the subject property (18 properties); and on July 1, 2026, the sign erected on Emerson Avenue was updated with the date of the July 16, 2026 hearing. PROCEDURE The LDC has always provided for administrative approval of Final Development Plans for land located within the PTV (Planned Town or Village), PRW (Planned Retail/Workplace) or PCS (Planned Country Subdivision) Zoning Districts, that is, TVC Zoning Districts, that are in substantial conformity with the Preliminary Development Plan approved by the Board. Pursuant to Ordinance 2025-014, effective July 17, 2025, Final Development Plans that are in substantial conformity with the approved Preliminary Development Plan are Minor Site Plans and administrative approval is available County-wide. Pursuant to LDC 11.02.02.C.7., the Planning and Development Services Director may determine that “any development of land, where the proposed development should be more thoroughly considered and reviewed because of its location or potential impact on public facilities, natural resources and public safety” should be designated a Major Site Plan that requires review and approval by the Board of County Commissioners at a regular meeting. STAFF RECOMMENDATION: Based on the analysis contained in this report, staff finds that the application, as currently submitted, does not demonstrate compliance with all applicable provisions of the St. Lucie County Comprehensive Plan and Land Development Code. Staff recommends that the Planning and Zoning Commission receive the Applicant’s presentation, staff’s presentation, and public comment; provide input regarding the identified interpretation and modification issues; and continue the public hearing to a date certain. The continuance would allow the Applicant to submit a revised Preliminary Development Plan and supporting documentation addressing the deficiencies identified in this report. Page 50 of 456 Project Name: The Club at Indrio Creek File No.: PD-2510-000058 Page 41 of 42 Staff is not recommending approval or denial at this time. Staff will provide a final recommendation after the revised plans and supporting information have been reviewed. Required Plan Revisions and Potential Conditions of Approval: Based on the analysis contained in this report, staff finds that the application, as currently submitted, does not demonstrate compliance with all applicable provisions of the St. Lucie County Comprehensive Plan and Land Development Code. Staff recommends that the Planning and Zoning Commission receive the Applicant’s presentation, staff’s presentation, and public comment; provide input regarding the identified interpretation and modification issues; and continue the public hearing to a date certain. The continuance would allow the Applicant to submit a revised Preliminary Development Plan and supporting documentation addressing the deficiencies identified in this report. Staff is not recommending approval or denial at this time. Staff will provide a final recommendation after the revised plans and supporting information have been reviewed. 1. The Preliminary Regulating Plan shall demonstrate compliance with the standards in LDC 3.01.03.EE.2.p. applicable to flow ways, including provision of a pedestrian and bicycle trail system along at least one side of the flow way system (LDC 3.01.03.EE.2.p.(3)), the width and design of littoral zones and native upland edge vegetation (LDC 3.01.03.EE. 2.p.(4)), and navigability by non-motorized craft such as canoes and kayaks (LDC 3.01.03.EE.2.p.(5)). Notwithstanding the foregoing, the references to transect zones in LDC Sections 3.01.03.EE.2.p.(2)ii. and 3.01.03.EE.2.p.(3)ii. shall not be applicable. Further, LDC 3.01.03.EE.2.p(6)i(1), (4) and (5) and LDC 3.01.03.EE.2.p(6)ii. shall not be applicable. LDC 3.01.03.EE.2.p(6)i(2) and (3) shall be applicable. A minimum of twenty (20) square ft. of vegetated and functional littoral zone and twenty (20) square ft. of upland buffer shall be established per linear foot of shoreline as part of the Flow Way System, per LDC 3.01.03.EE.2.p. The upland buffer shall be located such that no less than fifty percent (50%) of the total shoreline is buffered by a minimum width of twenty (20) ft. of upland habitat. A minimum twenty-five percent (25%) of shoreline shall be designed as a wide littoral zone habitat at least sixty (60) feet in width. The littoral zone established shall consist entirely of native vegetation and shall be maintained as part of the water management system. Page 51 of 456 Project Name: The Club at Indrio Creek File No.: PD-2510-000058 Page 42 of 42 The two additional stormwater treatment lakes identified on the plan shall provide no less than ten feet of littoral zone and 10 feet of native upland buffer per linear foot of shoreline. A Lake Management Plan is required and a single entity, acceptable to the County, shall be responsible for the long-term operation, maintenance and compliance monitoring. 2. As required by LDC 7.01.04.B. 9.c. regarding dedication of the land devoted to common open space, prior to the Final Development Plan being stamped approved, the Developer shall provide for the phased conveyance of the land to be used for common space to a public or acceptable private agency that will, upon acceptance, agree to maintain the common open space and any buildings, structures or improvements that have been placed on it. The schedule for the phased conveyance of any such lands to be used for common open space shall be a specific condition of approval for the Final Site Plan. 3. A finalized landscape plan consistent with LDC 7.09.00 shall be provided to and approved by ERD. 4. A finalized tree mitigation plan consistent with LDC 6.00.05 shall be provided to and approved by ERD. 5. The Preliminary Regulating Plan must acknowledge and address the 9% workforce housing required pursuant to LDC 7.01.04.B.2. The types, location, and phasing of workforce housing (no less than 4 percent of the dwelling units must be affordable to households with incomes between 80% and 100% of Area Median Income and no less than 4% must be affordable to households earning between 100% and 120% of the Area Median Income), the period of affordability (8 years), and that the mix of unit sizes (number of bedrooms), tenure, distribution within the community, and timing of construction of workforce dwellings will be roughly commensurate with the market rate units. 6. Vehicular access shall be provided to Seminole Road, such access shall not be limited to emergency access only and shall be via a standard road including a sidewalk. 7. Provide a proposed Habitat Restoration and Maintenance Plan for the proposed Restored/Created Native Habitat. 8. Provide for all sidewalks to be 6 feet in width. Page 52 of 456 Resolution No. 2026-XXX Page 1 RESOLUTION 2026-XXX File Number: PD-2510-000058 A RESOLUTION OF THE BOARD OF COUNTY COMMISSIONERS OF ST. LUCIE COUNTY GRANTING A CHANGE IN ZONING FROM THE AG-1 (AGRICULTURAL-1) ZONING DISTRICT TO THE PTV (PLANNED TOWN OR VILLAGE) ZONING DISTRICT; FURTHER GRANTING A PRELIMINARY PLANNED TOWN OR VILLAGE ON 126.32 ACRES (MORE OR LESS) AND LOCATED APPROXIMATELY 900 FEET SOUTH OF INDRIO ROAD, BETWEEN EMERSON AVENUE AND SEMINOLE ROAD, IN ST. LUCIE COUNTY, FLORIDA WHEREAS, the Board of County Commissioners of St. Lucie County, Florida, based upon acceptable evidence, including but not limited to the staff report, has made the following determinations: ZONING ATLAS AMENDMENT 1) Fort Pierce Holdings, LP presented a petition for a Change in Zoning from AG-1 (Agricultural – 1, 1 du/acre) Zoning District to the PTV (Planned Town or Village) Zoning District and Preliminary Planned Village Regulating Plan approval for the project known as The Club at Indrio Creek PTV, a residential subdivision of +/- 126.32 acres located approximately 900 feet south of Indrio Road, between Emerson Avenue and Seminole Road. 2) On July 16, 2026, the St. Lucie County Planning and Zoning Commission held a public hearing on the petition, after publishing a notice of such hearing in the St. Lucie News Tribune at least 10 days prior to the hearing and notifying by mail all owners of property within 500 feet of the subject property at least 10 days prior to the hearing, and the posting of a sign on the subject site at least 10 days prior to the hearing, and recommended that the Board of County Commissioners approve/deny the hereinafter described request for the property described in Part “A”. 3) On ________________, _______, this Board held a public hearing on the petition after publishing a notice of such hearing in the St. Lucie News Tribune, notifying by mail all owners of the property within 500 feet of the subject property, and the posting of a sign on the property, all notice completed at least 10 days prior to the hearing. 4) Based on the analysis presented in the staff report and presented at the public hearings, the proposed zoning change is/is not consistent with the St. Lucie County Comprehensive Plan and has satisfied the requirements of Section 11.02.07. of the St. Lucie County Land Development Code. Page 53 of 456 Resolution No. 2026-XXX Page 2 PRELIMINARY REGULATING PLAN 5) Fort Pierce Holdings, LP, presented a petition for a Preliminary Plan Town or Village Regulating Plan to be known as The Club at Indrio Creek PTV on +/- 126.32-acres to develop a planned town with the following mix of uses: 129 Single-family homes 246 Multi-family homes Two civic building lots 6) On July 16, 2026, the St. Lucie County Planning and Zoning Commission held a public hearing on the petition, after publishing a notice of such hearing in the St. Lucie News Tribune at least 10 days prior to the hearing and notifying by mail all owners of property within 500 feet of the subject property at least 10 days prior to the hearing, and erection of a sign on the property at least 10 days prior to the hearing, and recommended that the Board of County Commissioners approve the hereinafter described request for the property described in Part “A”. 7) On ________________, _______, this Board held a public hearing on this petition after publishing a notice of such hearing in the St. Lucie News Tribune at least 10 days prior to the hearing, notifying by mail all owners of property within 500 feet of the subject property at least 10 days prior to the hearing, erection of a sign on the property at least 10 days prior to the hearing. 8) The St. Lucie County Development Review Committee (DRC) has reviewed the Preliminary Plan Town Regulating Plan and found it to generally meet all technical requirements and to be consistent with the Future Land Use Map and the St. Lucie County Comprehensive Plan, subject to the conditions set forth in Part “C” of this Resolution. 9) The proposed project, in adherence with the presented conditions of approval, will not have an undue adverse effect on adjacent property, the character of the neighborhood, traffic conditions, parking, utility facilities, or other matters affecting the public health, safety, and general welfare. The Planned Village design provides for a walkable neighborhood with an interconnected street network to facilitate traffic movement. The applicant has funded and constructed water and sewer lines out to the subject property to support utilities being brought to this future development area. Page 54 of 456 Resolution No. 2026-XXX Page 3 10) All reasonable steps have been taken to minimize any adverse effect of the proposed buildings or use on the immediate vicinity through building design, site design, landscaping, and screening. 11) The proposed development will be constructed, arranged, and operated so as not to interfere with the development and use of neighboring property, in accordance with applicable district regulations. The proposed development is consistent with the Towns, Villages, and Countryside (TVC) development standards, which take into the account incremental development of the entire TVC Overlay Zone. 12) The proposed project will be served by St. Lucie County Water and Sewer District for potable water and wastewater. NOW, THEREFORE, BE IT RESOLVED by the Board of County Commissioners of St. Lucie County, Florida: ZONING ATLAS AMENDMENT A. The property on which the Zoning Atlas Amendment, or change in zoning, from AG-1 (Agricultural – 1) to PTV (Planned Town or Village) is being granted is described as follows: Legal Description: BEING THE SOUTH 1/2 OF THE NORTHWEST 1/4 OF THE SOUTHWEST 1/4, LESS CANAL RIGHT-OF WAY; LESS THE EAST 43 FEET OF THE WEST 48 FEET THEREOF; AND LESS EMERSON AVENUE; AND ALSO LESS THE NORTH 170.00 FEET; BEING THE WEST 1/2 OF THE SOUTHEAST 1/4 OF THE SOUTHWEST 1/4; BEING THE SOUTHWEST 1/4 OF THE SOUTHWEST 1/4, LESS CANAL RIGHT-OF-WAY AND LESS THE EAST 43 FEET OF THE WEST 48 FEET THEREOF; ALL IN SECTION 14, TOWNSHIP 34 SOUTH, RANGE 39 EAST, AND BEING THAT PART OF THE NORTH 230 FEET OF THE NORTHEAST 1/4 OF THE NORTHWEST 1/4, OF SECTION 23, TOWNSHIP 34 SOUTH, RANGE 39 EAST, ST. LUCIE COUNTY, FLORIDA, LYING WEST OF THE SOUTHERLY EXTENSION OF THE EAST LINE OF THE WEST 1/2 OF THE SOUTHEAST 1/4 OF THE SOUTHWEST 1/4 OF SECTION 14, TOWNSHIP 34 SOUTH, RANGE 39 EAST, ST. LUCIE COUNTY, FLORIDA; AND BEING THE NORTH 6.18 ACRES OF THE NORTHWEST 1/4 OF THE NORTHWEST 1/4, LESS CANAL RIGHT-OF-WAY AND LESS THE EAST 40 FEET OF THE WEST 48 FEET THEREOF IN SECTION 23, TOWNSHIP 34 SOUTH, RANGE 39 EAST. ST. LUCIE COUNTY, FLORIDA. TOGETHER WITH THE NORTH 3/4 OF THE NORTH 1/2 OF THE NORTHEAST 1/4 OF THE NORTHWEST 1/4 LESS THE NORTH 230 FEET, SECTION 23, TOWNSHIP 34 SOUTH, RANGE 39 EAST, ALL IN ST. LUCIE COUNTY, FLORIDA, LESS RIGHTS-OF-WAY FOR CANALS AND PUBLIC ROADS AS EXISTING. TOGETHER WITH Page 55 of 456 Resolution No. 2026-XXX Page 4 THE SOUTH HALF (1/2) OF THE NORTHEAST QUARTER (1/4) OF THE SOUTHWEST QUARTER (1/4) OF SECTION 14, TOWNSHIP 34 SOUTH, RANGE 39 EAST, ST. LUCIE COUNTY, FLORIDA; LESS AND EXCEPT RIGHTS OF WAY FOR PUBLIC ROADS AND DRAINAGE CANALS. LESS AND EXCEPT THE NORTH 208.71 FEET OF THE EAST 208.71 FEET, THEREOF. TOGETHER WITH THE EAST (1/2) OF THE SOUTHEAST QUARTER (1/4) OF THE SOUTHWEST (1/4) OF SECTION 14, TOWNSHIP 34 SOUTH, RANGE 39 EAST, ST. LUCIE COUNTY, FLORIDA. LESS AND EXCEPTING ALL EXISTING RIGHTS OF WAY FOR PUBLIC ROADS AND DRAINAGE CANALS. CONTAINING: 127.029 ACRES, MORE OR LESS Parcel ID Numbers: 1323-211-0005-000-8 1314-313-0000-000-8 1314-323-0002-000-3 1314-331-0001-000-1 1314-341-0000-000-5 1314-342-0001-000-5 B. The St. Lucie County Planning and Development Services Director shall be authorized to amend the Official Zoning Map to change the zoning of the property herein described, from AG-1 (Agricultural – 1, 1 du/acre) to PTV (Planned Town or Village) and to make notation of the reference to the date of adoption of this resolution. PRELIMINARY PLANNED TOWN REGULATING PLAN C. Pursuant to 11.02.07. of the St. Lucie County Land Development Code, the Planned Town Preliminary Regulating Plan for the project known The Club at Indrio Creek PTV is hereby approved/denied, for the subject property described in Part “A” above and as shown on the Regulating Plan drawings for the project prepared by Haley Ward, Inc. dated June 29, 2026, and date stamped received by the St. Lucie County Planning & Development Services Department on June 29, 2026 as attached and incorporated herein as Exhibit “C” subject to the following conditions: 1. The Preliminary Regulating Plan shall demonstrate compliance with the standards in LDC 3.01.03.EE.2.p. applicable to flow ways, including provision of a pedestrian and bicycle trail system along at least one side of the flow way system (LDC 3.01.03.EE.2.p.(3)), the width and design of littoral zones and native upland edge vegetation (LDC 3.01.03.EE. 2.p.(4)), and navigability by non-motorized craft such as canoes and kayaks (LDC 3.01.03.EE.2.p.(5)). Notwithstanding the foregoing, the references to transect zones in LDC Sections 3.01.03.EE.2.p.(2)ii. and 3.01.03.EE.2.p.(3)ii. shall not be Page 56 of 456 Resolution No. 2026-XXX Page 5 applicable. Further, LDC 3.01.03.EE.2.p(6)i(1), (4) and (5) and LDC 3.01.03.EE.2.p(6)ii. shall not be applicable. LDC 3.01.03.EE.2.p(6)i(2) and (3) shall be applicable. A minimum of twenty (20) square ft. of vegetated and functional littoral zone and twenty (20) square ft. of upland buffer shall be established per linear foot of shoreline as part of the Flow Way System, per LDC 3.01.03.EE.2.p. The upland buffer shall be located such that no less than fifty percent (50%) of the total shoreline is buffered by a minimum width of twenty (20) ft. of upland habitat. A minimum twenty-five percent (25%) of shoreline shall be designed as a wide littoral zone habitat at least sixty (60) feet in width. The littoral zone established shall consist entirely of native vegetation and shall be maintained as part of the water management system. The two additional stormwater treatment lakes identified on the plan shall provide no less than ten feet of littoral zone and 10 feet of native upland buffer per linear foot of shoreline. A Lake Management Plan shall be submitted to ERD and subject to ERD’s approval. A single entity, acceptable to the County, shall be named the responsible party for the long-term operation, maintenance and compliance monitoring. 2. As required by LDC 7.01.04.B.9.c. regarding dedication of the land devoted to common open space, prior to the Final Development Plan being stamped approved, the Developer shall provide for the phased conveyance of the land to be used for common space to a public or acceptable private agency that will, upon acceptance, agree to maintain the common open space and any buildings, structures or improvements that have been placed on it. The schedule for the phased conveyance of any such lands to be used for common open space shall be a specific condition of approval for the Final Regulating Plan. 3. A finalized landscape plan consistent with LDC 7.09.00. shall be provided to and approved by ERD. 4. A finalized tree mitigation plan consistent with LDC 6.00.05. shall be provided to and approved by ERD. 5. The Preliminary Regulating Plan must acknowledge and address the 9% workforce housing required pursuant to LDC 7.01.04.B.2. The types, location, and phasing of workforce housing (no less than 4 percent of the dwelling units must be affordable to households with incomes between Page 57 of 456 Resolution No. 2026-XXX Page 6 80% and 100% of Area Median Income and no less than 4% must be affordable to households earning between 100% and 120% of the Area Median Income), the period of affordability (8 years), and that the mix of unit sizes (number of bedrooms), tenure, distribution within the community, and timing of construction of workforce dwellings will be roughly commensurate with the market rate units. 6. Vehicular access shall be provided to Seminole Road, such access shall not be limited to emergency access only and shall be via a standard road including a sidewalk. 7. A Habitat Restoration and Maintenance Plan for the proposed Restored/Created Native Habitat shall be submitted to ERD and subject to the approval of ERD. 8. Provide for all sidewalks to be no less than 6 feet in width. D. The conditions set forth in Part “C” are an integral non-severable part of the Regulating Plan approval granted by this Resolution. If any condition set forth in Part “G” is determined to be invalid or unenforceable for any reason and the developer declines to comply voluntarily with that condition, the Regulating Plan approval granted by this resolution shall become null and void. E. A Concurrency Deferral Affidavit for future phases, a copy which is attached to this Resolution as Exhibit “B”, was signed by the applicant on September 24, 2025. F. A copy of this Resolution shall be mailed to the owner of record as identified on the application. G. This Resolution shall be recorded in the Public Records. Page 58 of 456 Resolution No. 2026-XXX Page 7 H. ADOPTION After motion and second, the vote on this resolution was as follows: Jaime Fowler, Chair XXX Larry Leet, Vice-Chair XXX Erin Lowry, Commissioner XXX James Clasby, Commissioner XXX Cathy Townsend, Commissioner XXX PASSED AND DULY ADOPTED this __________________, ___________. BOARD OF COUNTY COMMISSIONERS ST. LUCIE COUNTY, FLORIDA BY_________________________ Chair ATTEST: APPROVED AS TO FORM AND CORRECTNESS: ___________________ _______________________ DEPUTY CLERK COUNTY ATTORNEY Page 59 of 456 Resolution No. 2026-XXX Page 8 EXHIBIT “A” LOCATION MAP Page 60 of 456 Resolution No. 2026-XXX Page 9 EXHIBIT B CONCURRENCY DEFERRAL AFFIDAVIT FUTURE TRACT DEVELOPMENT Page 61 of 456 Resolution No. 2026-XXX Page 10 EXHIBIT C PTV PRELIMINARY REGULATING PLAN Page 62 of 456 SUGGESTED MOTIONS: The Club at Indrio Creek PTV MOTION TO CONTINUE: AFTER CONSIDERING THE TESTIMONY PRESENTED DURING THE PUBLIC HEARING, INCLUDING STAFF COMMENTS, AND THE STANDARDS OF REVIEW AS SET FORTH IN SECTION 11.02.07., ST. LUCIE COUNTY LAND DEVELOPMENT CODE, AT THE SUGGESTION OF STAFF, I HEREBY MOVE THAT THE PLANNING AND ZONING COMMISSION CONTINUE THIS PUBLIC HEARING UNTIL ITS AUGUST 20, 2026 MEETING, TO ENABLE THE APPLICANT AND THE STAFF TO WORK TOGETHER TO MAKE REFINEMENTS TO THE PROPOSED PLAN THAT MAY RESULT IN A STAFF RECOMMENDATION OF APPROVAL. MOTION TO APPROVE: AFTER CONSIDERING THE TESTIMONY PRESENTED DURING THE PUBLIC HEARING, INCLUDING STAFF COMMENTS, AND THE STANDARDS OF REVIEW AS SET FORTH IN SECTION 11.02.07., ST. LUCIE COUNTY LAND DEVELOPMENT CODE, I HEREBY MOVE THAT THE PLANNING AND ZONING COMMISSION RECOMMEND THAT THE ST. LUCIE COUNTY BOARD OF COUNTY COMMISSIONERS GRANT APPROVAL FOR THE PETITION OF FORT PIERCE HOLDINGS, LP FOR AN AMENDMENT TO THE OFFICIAL ZONING ATLAS FROM THE AG-1 ZONING DISTRICT TO THE PTV ZONING DISTRICT AND PRELIMINARY REGULATING PLAN TO DEVELOP A VILLAGE, BECAUSE..... [CITE REASON(S) WHY – PLEASE BE SPECIFIC] MOTION TO DENY: AFTER CONSIDERING THE TESTIMONY PRESENTED DURING THE PUBLIC HEARING, INCLUDING STAFF COMMENTS, AND THE STANDARDS OF REVIEW AS SET FORTH IN SECTION 11.02.07., ST. LUCIE COUNTY LAND DEVELOPMENT CODE, I HEREBY MOVE THAT THE PLANNING AND ZONING COMMISSION RECOMMEND THAT THE BOARD OF COUNTY COMMISSIONERS DENY FOR THE PETITION OF FORT PIERCE HOLDINGS, LP FOR AN AMENDMENT TO THE OFFICIAL ZONING ATLAS FROM THE AG-1 ZONING DISTRICT TO THE PTV ZONING DISTRICT AND PRELIMINARY REGULATING PLAN TO DEVELOP A VILLAGE, BECAUSE..... [CITE REASON(S) WHY – PLEASE BE SPECIFIC] Page 63 of 456 PLAN SNAPSHOT REPORT PD-2510-000058 FOR ST LUCIE COUNTY Planned Development 10/01/2025App Date:Project:Plan Type:The Club at Indrio Creek (PR-001368-2025) 1Preliminary 10/01/2027Exp Date:District:Work Class: 0.00Fees Paid NOT COMPLETEDCompleted:Square Feet:Status: Description: Valuation: On Behalf of the Owner, Haley Ward is requesting approval of a rezoning application to rezone the subject parcels from Agricultual-1 (AG-1) to Planned Town or Village (PTV). The intent of this application is to allow for the development of 408 units (single-family and multi-family) as a Village. Additional features of this project include a clubhouse/amenity center, outdoor civic park spaces, a flow way spanning from the North end of the site to the South, as well as greenways for pedestrian connectivity. The six (6) subject properties are 127.03 acres total and are located south of Indrio Road between Emerson Avenue and Seminole Road. $0.00 Assigned To:Szedlmayer, Irene Approval Expire Date: Parcel:131431300000008 132321100050008 131434100000005 131434200010005 131433100010001 Main131432300020003 Address:4575 Seminole Rd Fort Pierce, FL 34951 Main Zone:ROW(ROW) AG-1(AG-1) Agent Brad Currie Business: (772) 462-2455 Applicant Michelle Sullivan 10250 SW Village Parkway, Suite 201 Port St. Lucie, FL 34987 Business: (772) 462-2455 Agent Patricia Sesta 10250 SW Village Parkway, Suite 201 Port St. Lucie, FL 34987 Business: (772) 462-2455 Agent Dante Fraiegari Mobile: (727) 514-0788 Applicant Jared Bensky Home: (772) 462-2455 Business: (772) 462-2455 Agent Connor Kennedy 10250 SW Village Pkwy Suite 201 Suite 201 Port St. Lucie, FL 34987 Business: (772) 462-2455 Plan Custom Fields Project Name The Club at Indrio Creek Acres 15.42 Future Land Use Designation Towns, Villages, & Countryside (TVC) Zoning District Agricultural - 1 (AG-1)Legal Description 14 34 39 S 1/2 OF NW 1/4 OF SW 1/4-LESS N 170 FT AND LESS CANAL AND RD RS/W (15.42 AC) Existing Use of Property GRZNG SLD CP Project Category Residential Type of Use Proposed Residential Description of Specific Use if "Other": Current Zoning of Property Agricultural-1 (AG-1)Proposed Zoning Planned Town or Village (PTV) Current Future Land Use Towns, Villages, & Countryside (TVC) Acreage of the Area to be Rezoned 127.03 In Conflict This rezoning application is not requesting any deviation from the LDC. Changed Conditions The site is currently undeveloped. Adjacent properties are being developed with a mix of uses, warranting the need for more homes. This rezone would allow the development of a Village. Need for Rezoning Per Policy 1.1.1.3, Agricultural-1 (AG-1) is not a permitted zoning district within the Towns, Villages, & Countryside (TVC) Future Land Use. Page 1 of 772300 Virginia Avenue July 10, 2026 Page 64 of 456 PLAN SNAPSHOT REPORT (PD-2510-000058) Change Consistent Per Policy 1.1.1.3, Planned Town or Village (PTV) is a permitted zoning district within the Towns, Villages, & Countryside (TVC) Future Land Use. Existing Land Use Per Policy 1.1.1.3, Planned Town or Village (PTV) is a permitted zoning district within the Towns, Villages, & Countryside (TVC) Future Land Use. Public Facilities A concurrency deferral affidavit has been included as part of this submittal. There are no known negative impacts to the public facilities listed above. Affects Environment Please refer to the Environmental Assessment (EA) included as part of this submittal. Orderly and Logical The TVC land development regulations are a highly prescriptive form-based code that guides the intensity and design of development through the application of the transect zones and lot/street types offered. Adversely Affect There is no reason to believe the proposed rezoning will adversely impact property values in the area. Applicant's Interest The applicant is the owner of the subject properties. Other Information N/A Please acknowledge here Yes Attachment File Name Added On Added By Attachment Group Notes Signature_Michelle_Sullivan_10/1/2025.j pg 10/01/2025 14:42 Sullivan, Michelle Uploaded via CSS ERDv1.3 The Club at Indrio Creek PD-2510-000058 DRL.docx 10/23/2025 15:15 Ingram, Brian Available Online DRC comments.pdf 10/24/2025 9:06 Nelson, Melody Available Online FPUA comments DRC Report.Draft.10.30.25.Club at Indrio Creek.pdf 10/30/2025 1:09 Szedlmayer, Irene Development Review Committee (DRC) ERDv2.1 The Club at Indrio Creek PD-2510-000058 DRL.docx 01/30/2026 10:08 Ingram, Brian Available Online ERDv3 The Club at Indrio Creek PD-2510-000058 DRL.docx 05/12/2026 15:47 Ingram, Brian Available Online School Planning & Capacity Worksheet 2024.pdf 05/18/2026 14:00 Szedlmayer, Irene Development Review Committee (DRC) Page 2 of 772300 Virginia Avenue July 10, 2026 Page 65 of 456 St. Lucie County | September 29, 2025| 25-113 | Page 1 LETTER OF JUSTIFICATION The Club at Indrio Creek Rezoning Application September 29, 2025 REQUEST On Behalf of the Owner, Haley Ward is requesting approval of a rezoning application to rezone the subject parcels from Agricultual-1 (AG-1) to Planned Town or Village (PTV). The intent of this application is to allow for the development of 408 single-family and multi- family residential units as a Village. Additional features of this project include a clubhouse/amenity center, outdoor civic park spaces, a flow way spanning from the North end of the site to the South, as well as greenways for pedestrian connectivity. The six (6) subject properties are 127.03 acres total and are located south of Indrio Road between Emerson Avenue and Seminole Road. The subject parcels are noted below: Parcel ID Parcel Address Acreage Current FLU Current Zoning 1314-331-0001-000-1 Emerson Ave 43.1 TVC AG-1 1314-342-0001-000-5 Seminole Rd 24.71 TVC AG-1 1314-313-0000-000-8 Seminole Rd 18.13 TVC AG-1 1314-341-0000-000-5 Seminole Rd 17.74 TVC AG-1 1314-323-0002-000-3 Emerson Ave 15.42 TVC AG-1 1323-211-0005-000-8 Seminole Rd 7.93 TVC AG-1 TOTAL ACRES: 127.03 AERIAL Page 66 of 456 St. Lucie County | September 29, 2025| 25-113 | Page 2 SITE CHARACTERISTICS & PROJECT HISTORY The subject properties have a Future Land Use Designation of Towns, Villages, & Countryside (TVC) and are located in the Agricultural - 1 (AG-1) Zoning district. To the north of the subject parcels lie single-family residences. The properties have a Future Land Use Designation of Towns, Villages, & Countryside (TVC) and are located in the Agricultural - 1 (AG-1) Zoning district. To the east of the subject parcels lies the right-of-way for Seminole Road followed by undeveloped agricultural land. These properties have a Future Land Use Designation of Towns, Villages, & Countryside (TVC) and are located in the Agricultural - 1 (AG-1) Zoning district. To the south of the subject parcels lie undeveloped agricultural land. These properties have a Future Land Use Designation of Towns, Villages, & Countryside (TVC) and are located in the Agricultural - 1 (AG-1) Zoning district. To the west of the subject parcels lies the right-of-way for Emerson Road followed by undeveloped agricultural land. These properties have a Future Land Use Designation of Towns, Villages, & Countryside (TVC) and are located in the Agricultural - 1 (AG-1) Zoning district. PLANNED TOWN OR VILLAGE (PTV) It is the intent of this application to rezone the properties to a PTV as permitted under the TVC Future Land Use. The proposed development follows the regulations outlined for a Village per St. Lucie County Land Development Regulations Section 3.01.03.EE. A regulating plan have been included as part of this submittal. The regulating plan outlines the transect zones, lot types and street types as noted per PTV code. DENSITY / DENSITY MULTIPLIERS The Transferable Development Value Map, Comp. Plan Figure 11-3, Transferable Development Value Map assigns a 2 du/acre Development Value for the majority of the site. The southern portion of the site is assigned a Development Value of 1 du/acre. Our office contacted SLC Planning staff and SLC GIS to determine the exact boundary between 1 and 2 du/acre through GIS layers. This map has been included as part of this submittal and is shown on the regulating plan. 408 units are being proposed on the127-acre site for a density of 3.2 du/acre. The density has been achieved by density multipliers for restored habitat, workforce housing, and countryside. Please refer to the density calculation spreadsheet included as part of this submittal which was created in collaboration with SLC Planning Staff. Based on the above and attached information, the applicant respectfully requests the approval of the rezone application and proposed regulating plan with the development outlined above. Page 67 of 456 Page 68 of 456 Page 69 of 456 Page 70 of 456 RESTORED HABITAT: (2 DU/ACRE)765,592 S.F. RESTORED HABITAT: (1 DU/ACRE)338,784 S.F. INTERIOR COUNTRYSIDE:658,509 S.F. FLOW WAY: (2 DU/ACRE)698,035 S.F. LITTORAL: (2 DU/ACRE)148,300 S.F. INTERIOR LAKES/SWALES PARK 287,501 S.F. EMERSON ROW DEDICATION: 130,007 S.F. SPINE ROW DEDICATION: 226,199 S.F. LME: (2 DU/ACRE)164,454 S.F. CIVIC BUILDING LOT 23,530 S.F. TOWNHOUSE LOT 568,338 S.F. SINGLE FAMILY LOT 908666 S.F. INTERIOR ROAD RIGHT OF WAY 589,548 S.F. E - T O B E- T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - C E E-C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-T O B E - T O B E - T O B E - T O B E - T O B E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E - C E E - C E E - C E E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E - T O B E - T O B E-TOB E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E - C E E - C E E - C E E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O B E - T O B N0 ° 3 5 ' 0 6 . 7 4 " E 80 . 9 3 5 L=1419.787,R=1608.000 D=50.5894 L=1379.595,R=1528.000 D=51.7310 N89° 57' 23.02"E 58.448 L=1348.435,R=1528.000 D=50.5626 L=1451.825, R=1608.000 D=51.7310 N89° 57' 23.02"E 60.006 P - T O B P-TOB P-TOB P-TOB P-TOB P - T O B P-T O B P-TOB P - C E P-CE P-CE P-CE P-CE P - C E P-CE P-CE P-TO B P- T O B P-TOB P-TOB P-CE P-CE P- C E P- C E P-CE P-CE P-CE E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E P - T O B P - T O E 120'50'120'22' ALLEY 80' R.O . W . 50' 9 0 ' ( T Y P ) 18 9 . 2 ' 200.3' 47 4 . 5 ' 298' P - T O E P - T O E P - T O E E - T O B E - T O B E - T O B 85' AS P H A L T R O A D DIR T R O A D END AS P H A L T R O A D E - T O B E - T O B 90' 90' 90' FIBE R HAN D H O L E & M A R K E R RUS S A K I S I N V E S T M E N T S L L C Parc e l I D : 1 3 1 4 - 3 2 3 - 0 0 0 1 - 0 0 0 - 6 N 17 0 F T O F S 1 / 2 O F N W 1 / 4 O F SW 1 / 4 - L E S S C A N A L A N D R D RW DIR T R O A D DIR T R O A D DIRT R O A D F.P . F . W . C . D . C A N A L N O . 6 FL O W W A Y 3. 4 ' 80 . 0 ' 4. 3 ' TYPICAL TOWNHOUSE LOT LAYOUTSCALE: 1"=40' A A B R25.00' 15' 15' PROPOSED CLUB HOUSE MIXED USE AREA PROPOSED FLOW WAY 698,035 S.F. PROPOSED R.O.W. DRAINAGE AREA 72,247 S.F. PROPOSED LAKE 88,967 S.F.PROPOSED C.S. #2 & OUTFALL PIPE PROPOSED C.S. #1 & OUTFALL PIPE F. P . F . W . C . D . C A N A L N O . 6 F. P . F . W . C . D . C A N A L N O . 5 PROPOSED LAKE 53,235 S.F. CIV I C BLD G LOT PROPOSED BOX CULVERT CIVI C BLD G LOT FOR EMERGENCY ACCESS ONLY PROPOSED PARK 145,299 S.F. P - T O B P - T O B P - T O B P - T O B P- T O B P-CE P - C E P - C E P- C E P- C E P - C E P - C E P - C E P - T O B P - T O B P - T O B P - T O B P - T O B P - T O B P - T O B P - T O B P - T O B P - T O B P - T O B P - T O B P - T O B P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-T O B P - T O B P - T O B P-TOB P-TO B P-T O B P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB B P R O P O S E D C L U B H O U S E 17.58 AC. 7.78 AC. 15.12 AC. 16.02 AC. 3.40 AC. 6.60 AC. 2.98 AC. 5.19 AC. 3.78 AC. 0.54 AC. 13.05 AC. 20.86 AC. 13.53 AC. E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E-TOB E-TOB E-CE E-CE E-TOE E-TOE DIR T R O A D 2 DU/ACRE LINE 1 DU/ACRE LINE 75 ' 35 ' 35' 75' 106 ' 20 ' 12 9 ' 20 ' 10 0 ' 131' 35 ' 35' 47 ' 35 ' 35' 20' 11 0 ' 20 ' 35' 20 ' 6 2 ' 20' 10' 20' 20' L.M.E. & UPLAND BUFFER 25 7 ' 30 4 ' 68 ' 151' 60 ' 241'27 2 ' 88 ' 85' 26 ' 20 ' 92 ' 22' A L L E Y 120' EXISTING METER PROPOSED MITERED END SECTION PROPOSED SIGN HANDICAP PARKING SYMBOL EXISTING CONCRETE EXISTING PAVEMENT EXISTING UTILITY POLE EXIST. DRAINAGE INLET EXISTING STREET LIGHT PROPOSED LIGHT POLE (SINGLE) DRAINAGE FLOW ARROW PROPOSED LIGHT POLE (DOUBLE) PARKING STALL COUNT PROPOSED CONCRETE PROPOSED DRAINAGE INLET EXISTING DRAINAGE PROPOSED DRAINAGE PIPE VERTICAL DATUM NOTE: ELEVATIONS SHOWN HEREON ARE RELATIVE TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (N.A.V.D.88) AND ARE GIVEN IN U.S. SURVEY FEET UNLESS OTHERWISE NOTED. *GENERAL ACCEPTED CONVERSION: NAVD + 1.475 = NGVD NOTE: THE PROPERTY OWNER, CONTRACTOR, AND AUTHORIZED REPRESENTATIVES SHALL PROVIDE PICKUP, REMOVAL, AND DISPOSAL OF LITTER WITHIN THE PROJECT LIMITS AND SHALL BE RESPONSIBLE FOR MAINTENANCE OF THE AREA FROM THE EDGE OF PAVEMENT TO THE PROPERTY LINE WITHIN THE RIGHT-OF-WAY PROPOSED PAVEMENT # ( IN FEET ) GRAPHIC SCALE 0150 75 150 300 450 1 inch = 150 ft. 10250 Village Parkway, Suite 201 Port Saint Lucie, Florida 34987 772.462.2455930 S. Harbor City Blvd, Suite 506Melbourne, FL 32901321.280.9969 1234567 PROJECT TITLE DATE SCALE DRAWN BY DESIGNED BY CHECKED BY PROJECT No. DRAWING No.REV. A B C D A B C D FIL E L O C A T I O N : P:\ F L \ 2 0 1 3 1 6 7 - F O R T _ P I E R C E _ H O L D I N G S _ G P _ I N C \ 2 5 - 1 1 3 - M O V E D 2 0 1 3 1 6 7 I N D R I O C R E E K - S E M I N O L E R O A D - 1 2 7 - A C R E S \ E N G I N E E R I N G \ A U T O C A D \ D W G S \ 2 5 - 1 1 3 R 2 9 . D W G , 20 2 6 . 0 6 . 2 9 , 10 : 3 0 A M CERTIFICATE OF AUTHORIZATION No. 1234567 HALEY WARD ENGINEERING ENVIRONMENTAL SURVEYING WWW.HALEYWARD.COM LAND PLANNING INTERIOR DESIGN REGULATING PLAN 6/29/2026 AS SHOWN JJL/RAH JJL/MAS MDL 25-113 R29.DWG REG C.O.A. No. DESCRIPTION BY CHK.DATE DRAWING ISSUE STATUS REV. 6-16-2026 RESPONSE TO ST. LUCIE COUNTY COMMENTS RAH MDL 1 1 Know what's below. Call before you dig. www.callsunshine.com It's fast. It's free. It's the law. 10250 SW VILLAGE PARKWAY - SUITE 201 PORT SAINT LUCIE, FL 34987 ' 772-462-2455 (DATE) THE CLUB AT INDRIO CREEK ST. LUCIE COUNTY, FLORIDA VICINITY MAP SCALE: 1:1,500SITE DATA LEGAL DESCRIPTION 1314-323-0002-000-3 14 34 39 S 1/2 OF NW 1/4 OF SW 1/4-LESS N 170 FT AND LESS CANAL AND RD RS/W (15.42 AC) 1314-313-0000-000-8 14 34 39 S 1/2 OF NE 1/4 OF SW 1/4-LESS N 208.71 FT OF E 208.71 FT AND LESS RD AND CANAL RS/W- (18.13 AC) 1314-331-0001-000-1 14/23 34 39 FROM SW COR SEC 14 RUN N 89 DEG 30 MIN 19 SEC E ALG S LI OF SEC 48 FT TO E R/W LI EMERSON AV AND POB, TH N 00 DEG 07 MIN 22 SEC E ALG SD E R/W 1311.43 FT TO C/L OF DITCH, TH N 89 DEG 49 MIN 59 SEC E ALG C/L 1218.78 FT, TH S 45 DEG 07 MIN 23 SEC E 46.22 FT, TH S 00 DEG 35 MIN 00 SEC W 1472.61 FT TO S LI OF N 6.18 AC OF NW 1/4 OF NW 1/4 OF SEC 23, TH S 89 DEG 30 MIN 19 SEC W 1239.97 FT TO E R/W EMERSON AV, TH N 00 DEG 10 MIN 00 SEC E 200.88 FT TO POB (43.14 AC) 1314-342-0001-000-5 14/23 34 39 W 1/2 OF SE 1/4 OF SW 1/4 AND N 230 FT OF NW 1/4 OF NE 1/4 OF NW 1/4 (24.72 AC) 1323-211-0005-000-8 23 34 39 N 3/4 OF N 1/2 OF NE 1/4 OF NW 1/4-LESS N 230 FT AND LESS E 90 FT (7.93 AC) PARCEL ID #: 1314-323-0002-000-3 1314-313-0000-000-8 1314-331-0001-000-1 1314-342-0001-000-5 1323-211-0005-000-8 1314-341-0000-000-5 PROJECT NAME: THE CLUB AT INDRIO CREEK OWNERSHIP:BRINDHAVANAM LLC 4528 SHILOH MILL BLVD JACKSONVILLE, FL 32246-1877 FUTURE LAND USE: TVC CURRENT ZONING: AG-1 PROPOSED ZONING:PTV LAND SIZE:5,502,629 S.F. (126.323 AC) BUILDING DATA TOTAL UNIT 375 UNITS PROPOSED SINGLE FAMILY 129 UNITS PROPOSED TOWNHOMES 246 UNITS PROVIDER OF UTILITIES: WATER: FPUA WASTEWATER: FPUA IRRIGATION: WELL SOLID WASTE: ROLL OUT AND DUMPSTER AUTHORIZED STORMWATER DRAINAGE: THE SURFACE WATER MANAGEMENT SYSTEM FOR THE PROJECT WILL COLLECT SITE RUNOFF IN A SERIES OF INLETS WHICH WILL CONVEY THE RUNOFF TO THE ADJACENT F.P.F.W.C.D. CANAL SYSTEM. SOLID WASTE: BASED ON THE INTENDED USE OF THE SITE, THIS PROJECT WILL UTILIZE A COMBINATION OF DUMPSTERS AND ROLL OUT CARTS. HAZARDOUS WASTE: ANY AND ALL HAZARDOUS OR TOXIC MATERIALS GENERATED OR USED OR STORED ON SITE SHALL BE DISPOSED OF IN ACCORDANCE WITH ALL LOCAL, STATE AND FEDERAL REGULATIONS. LANDSCAPE: REFER TO LANDSCAPE PLAN BY OTHERS. (NO PLANS AVAILABLE) ANY NEW RESIDENTIAL STRUCTURE CONTAINING ONE (1), TWO (2), OR THREE (3) UNITS MUST PRESERVE OR PLANT ONE (1) NATIVE CANOPY TREE MEASURING 2.5” DIAMETER AT BREAST HEIGHT (DBH), FOR EVERY 2,500 SQUARE FEET OF THE SUBJECT LOT OR PARCEL OF LAND PER LDC 7.09.04.I. ACCESSIBILITY AND ADA COMPLIANCE: ALL SIDEWALKS AND RAMPS WILL MEET FDOT AND ADA REQUIREMENTS. SITE F.I.R.M. PANEL: 12111C0070J ST. LUCIE COUNTY UNINCORPORATED AREA 120285 ZONE X S E M I N O L E R O A D EM E R S O N A V E R.O.W. DEDICATION COUNTRYSIDE SINGLE FAMILY UNITS / VILLAS TOWNHOMES EM E R S O N A V E N U E SE M I N O L E R O A D INDRIO ROAD 14 6 0 ' 15' LANDSCAPE BUFFER 20' UPLAND BUFFER 20' LAKE MAINTENANCE EASEMENT LITTORAL SHELF 15' LANDSCAPE BUFFER 15' LANDSCAPE BUFFER Page 71 of 456 E - T O B E-T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - C E E-C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-T O B E - T O B E - T O B E - T O B E - T O B E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E - C E E - C E E - C E E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E - T O B E - T O B E-TOB E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E - C E E - C E E - C E E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O B E - T O B N0 ° 3 5 ' 0 6 . 7 4 " E 80 . 9 3 5 L=1419.787,R=1608.000 D=50.5894 L=1379.595,R=1528.000 D=51.7310 N89° 57' 23.02"E 58.448 L=1348.435,R=1528.000 D=50.5626 L=1451.825, R=1608.000 D =51.7310 N89° 57' 23.02"E 60.006 P - C E P-CE P-CE P-CE P-CE P - C E P-CE P-CE P-CE P-CE P- C E P- C E P-CE P-CE P-CE E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - T O B E - T O B E - T O B E - T O B E - T O B TYPICAL TOWNHOUSE LOT LAYOUTSCALE: 1"=40' RURAL TZ RURAL TZ RURAL TZ RURAL TZ TRANSECT ZONES CENTER CE 280,638 S.F. GENERAL G 1,477,399 S.F. RURAL R 2,210,547 S.F. EDGE E 641,164 S.F. MU CE F. P . F . W . C . D . CA N A L N O . 6 EM E R S O N A V E SE M I N O L E R O A D E CB E ALL E Y F. P . F . W . C . D . C A N A L N O . 5 50 ' I N T E R N A L R O W CB C E CB C E P-CE P - C E P - C E P- C E P- C E P - C E P - C E P - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E-TOB E-TOB E-CE E-CE E-TOE E-TOE RURAL TZ RURAL TZ RH G RH G RH G RH G RH GRH G RH G RH G RH G RH G RH G ALLEY AL L E Y AL L E Y 50 ' I N T E R N A L R O W 50' INTERNAL ROW 50' INTERNAL ROW 50' I N T E R N A L R O W 50 ' I N T E R N A L R O W 5 0 ' I N T E R N A L R O W RH G RH G RH G RH G AL L E Y MU E E E RURAL TZ RURAL TZ HO G HO G HO G HO G HO G HO G HO G HO G HO G HO G HO G HO G HO G HO GHO G HO G HO G HO G icrosoft Corporation © 2025 Maxar ©CNES (2025) Distribution Airbus DS © 2025 TMAP MOBILITY Earthstar Geographics SIO VICINITY MAP SCALE: 1:1,000 VERTICAL DATUM NOTE: ELEVATIONS SHOWN HEREON ARE RELATIVE TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (N.A.V.D.88) AND ARE GIVEN IN U.S. SURVEY FEET UNLESS OTHERWISE NOTED. *GENERAL ACCEPTED CONVERSION: NAVD + 1.475 = NGVD NOTE: THE PROPERTY OWNER, CONTRACTOR, AND AUTHORIZED REPRESENTATIVES SHALL PROVIDE PICKUP, REMOVAL, AND DISPOSAL OF LITTER WITHIN THE PROJECT LIMITS AND SHALL BE RESPONSIBLE FOR MAINTENANCE OF THE AREA FROM THE EDGE OF PAVEMENT TO THE PROPERTY LINE WITHIN THE RIGHT-OF-WAY SITE ( IN FEET ) GRAPHIC SCALE 0150 75 150 300 450 1 inch = 150 ft. 10250 Village Parkway, Suite 201 Port Saint Lucie, Florida 34987 772.462.2455930 S. Harbor City Blvd, Suite 506Melbourne, FL 32901321.280.9969 1234567 PROJECT TITLE DATE SCALE DRAWN BY DESIGNED BY CHECKED BY PROJECT No. DRAWING No.REV. A B C D A B C D FIL E L O C A T I O N : P:\ F L \ 2 0 1 3 1 6 7 - F O R T _ P I E R C E _ H O L D I N G S _ G P _ I N C \ 2 5 - 1 1 3 - M O V E D 2 0 1 3 1 6 7 I N D R I O C R E E K - S E M I N O L E R O A D - 1 2 7 - A C R E S \ E N G I N E E R I N G \ A U T O C A D \ D W G S \ 2 5 - 1 1 3 R 2 9 . D W G , 20 2 6 . 0 6 . 2 9 , 12 : 0 7 P M CERTIFICATE OF AUTHORIZATION No. 1234567 HALEY WARD ENGINEERING ENVIRONMENTAL SURVEYING WWW.HALEYWARD.COM LAND PLANNING INTERIOR DESIGN TRANSECT ZONES 6/29/2026 AS SHOWN JJL/RAH JJL/MAS MDL 25-113 R29.DWG TRANS C.O.A. No. DESCRIPTION BY CHK.DATE DRAWING ISSUE STATUS REV. 6-16-2026 RESPONSE TO ST. LUCIE COUNTY COMMENTS RAH MDL 1 1 Know what's below. Call before you dig. www.callsunshine.com It's fast. It's free. It's the law. 10250 SW VILLAGE PARKWAY - SUITE 201 PORT SAINT LUCIE, FL 34987 ' 772-462-2455 (DATE) THE CLUB AT INDRIO CREEK ST. LUCIE COUNTY, FLORIDA VICINITY MAP SCALE: 1:1,000 SITE SE M I N O L E R O A D EM E R S O N A V E Page 72 of 456 E - T O B E- T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - C E E-C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-T O B E - T O B E - T O B E - T O B E - T O B E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E - C E E - C E E - C E E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E - T O B E - T O B E-TOB E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E - C E E - C E E - C E E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O B E - T O B N0 ° 3 5 ' 0 6 . 7 4 " E 80 . 9 3 5 L=1419.787,R=1608.000 D=50.5894 L=1379.595,R=1528.000 D=51.7310 N89° 57' 23.02"E 58.448 L=1348.435,R=1528.000 D=50.5626 L=1451.825, R=1608.000 D=51.7310 N89° 57' 23.02"E 60.006 P - T O B P-TOB P-TOB P-TOB P-TOB P - T O B P-T O B P-TOB P - C E P-CE P-CE P-CE P-CE P - C E P-CE P-CE P-TO B P- T O B P-TOB P-TOB P-CE P-CE P- C E P- C E P-CE P-CE P-CE E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E P - T O B P - T O E P - T O E P - T O E P - T O E E - T O B E - T O B E - T O B E - T O B E - T O B BL O C K L E N G T H 3 4 7 L F PE R I M E T E R 88 3 L F BLOCK LENGTH 3 9 0 L F PERIMETER 932 LF B L O C K L E N G T H 3 3 8 L F P E R I M E T E R 9 1 5 L F BL O C K L E N G T H 4 8 4 L F PE R I M E T E R 994 LF BL O C K L E N G T H 3 5 5 L F P E R I M E T E R 92 5 L F BL O C K L E N G T H 3 0 0 L F PE R I M E T E R 86 6 L F BL O C K L E N G T H 3 4 2 L F PE R I M E T E R 92 3 L F BLOCK LENGTH 470 LF PERIMETER 1,180 LF BLOCK LENGTH 480 L.F. PERIMETER 1,200 LF BL O C K L E N G T H 1 5 9 L F BL O C K P E R I M E T E R 51 1 L F AVERAGE BLOCK PERIMETER 895 LF MAX BLOCK PERIMETER 1,217 LF FLOW WAY 6.39 AC TYPICAL TOWNHOUSE LOT LAYOUTSCALE: 1"=40' FLOW WAY BL O C K L E N G T H 3 4 2 L F PE R I M E T E R 87 9 L F BL O C K L E N G T H 3 5 1 L F PE R I M E T E R 89 3 L F P - T O B P - T O B P - T O B P - T O B P- T O B P-CE P - C E P - C E P- C E P- C E P - C E P - C E P - C E P - T O B P - T O B P - T O B P - T O B P - T O B P - T O B P - T O B P - T O B P - T O B P - T O B P - T O B P - T O B P - T O B P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-T O B P - T O B P - T O B P-TOB P-TO B P-T O B P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB B L O C K L E N G T H 2 9 9 L F P E R I M E T E R 8 1 9 L F BL O C K L E N G T H 3 9 0 L . F . PE R I M E T E R 1, 1 1 3 L F BLOCK LENGTH 350 L.F. PERIMETER 940 LF B L O C K L E N G T H 3 9 0 L F P E R I M E T E R 1, 0 5 8 L F BLOCK LENGTH 291 LF PERIMETER 821 LF BL O C K L E N G T H 3 6 0 L F PE R I M E T E R 96 0 L F BLOCK LENGTH 330 L.F. PERIMETER 900 LF BLO C K L E N G T H 3 6 6 L F PER I M E T E R 901 LF BL O C K L E N G T H 3 4 5 L F PE R I M E T E R 93 6 LF BLOC K L E N G T H 3 5 0 L F PERI M E T E R 1,030 LF BLOCK LENGTH 362 LF PERIMETER 922 LF BLOCK LENGTH 353 LF PERIMETER 896 LF BL O C K L E N G T H 3 0 4 L F PE R I M E T E R 789 LF BL O C K L E N G T H 3 9 8 L F PE R I M E T E R 94 6 LF BL O C K L E N G T H 3 7 8 L F PE R I M E T E R 97 0 L F BL O C K L E N G T H 4 9 5 L F PE R I M E T E R 1, 2 1 7 L F E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E-TOB E-TOB E-CE E-CE E-TOE E-TOE BL O C K L E N G T H 2 5 1 L . F . PE R I M E T E R 74 3 L F B L O C K L E N G T H 2 5 0 L F P E R I M E T E R 76 2 L F BL O C K L E N G T H 4 4 8 L F PE R I M E T E R 1, 1 0 0 L F BL O C K L E N G T H 3 6 5 L F PE R I M E T E R 89 1 L F BLOCK LENGTH 361 LF PERIMETER 901 LF BLOCK LENGTH 345 LF PERIMETER 877 LF BLO C K L E N G T H 1 8 9 L F PER I M E T E R 557 LF BLOCK LENGTH 3 4 2 L F PERIMETER 909 LF BLO C K L E N G T H 3 9 7 L F PER I M E T E R 943 LF BL O C K L E N G T H 1 7 0 L F PE R I M E T E R 53 4 L F BL O C K L E N G T H 3 5 3 L F PE R I M E T E R 91 1 L F BLOCK L E N G T H 1 7 2 L F PERIM E T E R 578 LF B L O C K L E N G T H 1 0 8 L F P E R I M E T E R 46 7 L F BL O C K L E N G T H 3 3 9 L . F . PE R I M E T E R 1, 0 7 8 L F BL O C K L E N G T H 2 1 9 L F PE R I M E T E R 68 0 L F BLOCK LENGTH 441 L.F. PERIMETER 1,122 LF icrosoft Corporation © 2025 Maxar ©CNES (2025) Distribution Airbus DS © 2025 TMAP MOBILITY Earthstar Geographics SIO VICINITY MAP SCALE: 1:1,000 VERTICAL DATUM NOTE: ELEVATIONS SHOWN HEREON ARE RELATIVE TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (N.A.V.D.88) AND ARE GIVEN IN U.S. SURVEY FEET UNLESS OTHERWISE NOTED. *GENERAL ACCEPTED CONVERSION: NAVD + 1.475 = NGVD NOTE: THE PROPERTY OWNER, CONTRACTOR, AND AUTHORIZED REPRESENTATIVES SHALL PROVIDE PICKUP, REMOVAL, AND DISPOSAL OF LITTER WITHIN THE PROJECT LIMITS AND SHALL BE RESPONSIBLE FOR MAINTENANCE OF THE AREA FROM THE EDGE OF PAVEMENT TO THE PROPERTY LINE WITHIN THE RIGHT-OF-WAY SITE ( IN FEET ) GRAPHIC SCALE 0150 75 150 300 450 1 inch = 150 ft. 10250 Village Parkway, Suite 201 Port Saint Lucie, Florida 34987 772.462.2455930 S. Harbor City Blvd, Suite 506Melbourne, FL 32901321.280.9969 1234567 PROJECT TITLE DATE SCALE DRAWN BY DESIGNED BY CHECKED BY PROJECT No. DRAWING No.REV. A B C D A B C D FIL E L O C A T I O N : P:\ F L \ 2 0 1 3 1 6 7 - F O R T _ P I E R C E _ H O L D I N G S _ G P _ I N C \ 2 5 - 1 1 3 - M O V E D 2 0 1 3 1 6 7 I N D R I O C R E E K - S E M I N O L E R O A D - 1 2 7 - A C R E S \ E N G I N E E R I N G \ A U T O C A D \ D W G S \ 2 5 - 1 1 3 R 2 9 . D W G , 20 2 6 . 0 6 . 2 9 , 10 : 3 0 A M CERTIFICATE OF AUTHORIZATION No. 1234567 HALEY WARD ENGINEERING ENVIRONMENTAL SURVEYING WWW.HALEYWARD.COM LAND PLANNING INTERIOR DESIGN BLOCK PLAN 6/29/2026 AS SHOWN JJL/RAH JJL/MAS MDL 25-113 R29.DWG BLOCK C.O.A. No. DESCRIPTION BY CHK.DATE DRAWING ISSUE STATUS REV. 2-16-2026 RESPONSE TO ST. LUCIE COUNTY COMMENTS RAH MDL 1 1 Know what's below. Call before you dig. www.callsunshine.com It's fast. It's free. It's the law. 10250 SW VILLAGE PARKWAY - SUITE 201 PORT SAINT LUCIE, FL 34987 ' 772-462-2455 (DATE) THE CLUB AT INDRIO CREEK ST. LUCIE COUNTY, FLORIDA VICINITY MAP SCALE: 1:1,000 SE M I N O L E R O A D EM E R S O N A V E F. P . F . W . C . D . C A N A L N O . 5 F. P . F . W . C . D . C A N A L N O . 6 EM E R S O N A V E N U E SE M I N O L E R O A D Page 73 of 456 E - T O B E- T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - C E E-C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-T O B E - T O B E - T O B E - T O B E - T O B E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E - C E E - C E E - C E E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E - T O B E - T O B E-TOB E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E - C E E - C E E - C E E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O B E - T O B N0 ° 3 5 ' 0 6 . 7 4 " E 80 . 9 3 5 L=1419.787,R=1608.000 D=50.5894 L=1379.595,R=1528.000 D=51.7310 N89° 57' 23.02"E 58.448 L=1348.435,R=1528.000 D=50.5626 L=1451.825, R=1608.000 D=51.7310 N89° 57' 23.02"E 60.006 P - T O B P-TOB P-TOB P-TOB P-TOB P - T O B P-T O B P-TOB P - C E P-CE P-CE P-CE P-CE P - C E P-CE P-CE P-TO B P- T O B P-TOB P-TOB P-CE P-CE P- C E P- C E P-CE P-CE P-CE E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E P - T O B P - T O E P - T O E P - T O E P - T O E E - T O B E - T O B E - T O B E - T O B E - T O B TYPICAL TOWNHOUSE LOT LAYOUTSCALE: 1"=40' P - T O B P - T O B P - T O B P - T O B P- T O B P-CE P - C E P - C E P- C E P- C E P - C E P - C E P - C E P - T O B P - T O B P - T O B P - T O B P - T O B P - T O B P - T O B P - T O B P - T O B P - T O B P - T O B P - T O B P - T O B P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-T O B P - T O B P - T O B P-TOB P-TO B P-T O B P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E-TOB E-TOB E-CE E-CE E-TOE E-TOE icrosoft Corporation © 2025 Maxar ©CNES (2025) Distribution Airbus DS © 2025 TMAP MOBILITY Earthstar Geographics SIO VICINITY MAP SCALE: 1:1,000 VERTICAL DATUM NOTE: ELEVATIONS SHOWN HEREON ARE RELATIVE TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (N.A.V.D.88) AND ARE GIVEN IN U.S. SURVEY FEET UNLESS OTHERWISE NOTED. *GENERAL ACCEPTED CONVERSION: NAVD + 1.475 = NGVD NOTE: THE PROPERTY OWNER, CONTRACTOR, AND AUTHORIZED REPRESENTATIVES SHALL PROVIDE PICKUP, REMOVAL, AND DISPOSAL OF LITTER WITHIN THE PROJECT LIMITS AND SHALL BE RESPONSIBLE FOR MAINTENANCE OF THE AREA FROM THE EDGE OF PAVEMENT TO THE PROPERTY LINE WITHIN THE RIGHT-OF-WAY SITE ( IN FEET ) GRAPHIC SCALE 0150 75 150 300 450 1 inch = 150 ft. 10250 Village Parkway, Suite 201 Port Saint Lucie, Florida 34987 772.462.2455930 S. Harbor City Blvd, Suite 506Melbourne, FL 32901321.280.9969 1234567 PROJECT TITLE DATE SCALE DRAWN BY DESIGNED BY CHECKED BY PROJECT No. DRAWING No.REV. A B C D A B C D FIL E L O C A T I O N : P:\ F L \ 2 0 1 3 1 6 7 - F O R T _ P I E R C E _ H O L D I N G S _ G P _ I N C \ 2 5 - 1 1 3 - M O V E D 2 0 1 3 1 6 7 I N D R I O C R E E K - S E M I N O L E R O A D - 1 2 7 - A C R E S \ E N G I N E E R I N G \ A U T O C A D \ D W G S \ 2 5 - 1 1 3 R 2 9 . D W G , 20 2 6 . 0 6 . 2 9 , 10 : 3 0 A M CERTIFICATE OF AUTHORIZATION No. 1234567 HALEY WARD ENGINEERING ENVIRONMENTAL SURVEYING WWW.HALEYWARD.COM LAND PLANNING INTERIOR DESIGN PEDESTRIAN PATH PLAN 6/29/2026 AS SHOWN RAH RAH/MS MDL 25-113 R29.DWG PED C.O.A. No. DESCRIPTION BY CHK.DATE DRAWING ISSUE STATUS REV. 6-16-2026 RESPONSE TO ST. LUCIE COUNTY COMMENTS RAH MDL 1 1 Know what's below. Call before you dig. www.callsunshine.com It's fast. It's free. It's the law. 10250 SW VILLAGE PARKWAY - SUITE 201 PORT SAINT LUCIE, FL 34987 ' 772-462-2455 (DATE) THE CLUB AT INDRIO CREEK ST. LUCIE COUNTY, FLORIDA VICINITY MAP SCALE: 1:1,000 SE M I N O L E R O A D EM E R S O N A V E F. P . F . W . C . D . C A N A L N O . 5 F. P . F . W . C . D . C A N A L N O . 6 EM E R S O N A V E N U E SE M I N O L E R O A D PEDESTRIAN ACCESS TYPICAL PEDESTRIAN ACCESS TYPICAL Page 74 of 456 COVERED ENTRY16'-0" x 7'-4" MULTI-PURPOSE16'-0" x 26'-10"FLEX / REC. ROOM 14-5" x 26'-10" COVERED PATIO47'-4" x 12'-0" AREA CALCULATION: CONDITIONED 1,349 SF COVERED ENTRY 117 SF COVERED PATIO 568 SF TOTAL 2,034 SF OFFICE 14'-5" x 12'-0" WOMEN'S R.R. 6'-6" x 7'-3" MEN'S R.R. 6'-11" x 7'-3" JAN. 2'-7" x 6'-6" CORRIDOR 47'-4" 7'- 4 " 28 ' - 6 " 12 ' - 0 " 47 ' - 1 0 " 15'-0"17'-4"15'-0" 47'-4" SINGLE FAMILY LOT (SF) 50' MIN. - 60' MAX. SCALE: 1"=40' 50' PORCH GARAGE 6' MIN. FRONT SETBACK 16' SEPERATION 22' GARAGE SETBACK DRIVEWAY CONNECTION TO THE STREET SUBJECT TO CHANGE BASED ON STREET TYPE 60' 120'5' SIDE SETBACK 5' SIDEWALK 10' REAR SETBACK REAR FRONT STREET TYPE. VARIES [SEE STREET TYPES AND REGULATING PLAN FOR ADJACENT STREET TYPES] 5' MIN. DRIVEWAY SIDE SETBACK PORCH GARAGE 16' SEPERATION 22' GARAGE SETBACK VILLAS SCALE: 1"=40' 70' 22' FRONT SETBACK 25' MIN.25' MIN. LOT LINE 5' SIDE SB 5' SIDE SB 10' REAR SETBACK 3' REAR SETBACK 0' WHEN ADJACENT TO LAKE 120' MIN. 22' SETBACK 10' U.E. 5' SIDEWALK GARAGE 11'-4" x 20'-1"GARAGE11'-4" x 20'-1" GARAGE11'-4" x 20'-1"GARAGE11'-4" x 20'-1" GARAGE11'-4" x 20'-1"GARAGE11'-4" x 20'-1"GARAGE 11'-4" x 20'-1" GARAGE11'-4" x 20'-1" 2 CARGARAGE19'-8" x 20'-1" GARAGE11'-4" x 20'-1"GARAGE11'-4" x 20'-1" 2 CARGARAGE19'-8" x 20'-1" GARAGE11'-4" x 20'-1"GARAGE11'-4" x 20'-1" GARAGE11'-4" x 20'-1"GARAGE11'-4" x 20'-1" GARAGE11'-4" x 20'-1"GARAGE11'-4" x 20'-1"GARAGE11'-4" x 20'-1" GARAGE11'-4" x 20'-1" 2 CARGARAGE19'-8" x 20'-1" GARAGE11'-4" x 20'-1"GARAGE11'-4" x 20'-1" 2 CARGARAGE19'-8" x 20'-1" 10250 Village Parkway, Suite 201 Port Saint Lucie, Florida 34987 772.462.2455930 S. Harbor City Blvd, Suite 506Melbourne, FL 32901321.280.9969 1234567 PROJECT TITLE DATE SCALE DRAWN BY DESIGNED BY CHECKED BY PROJECT No. DRAWING No.REV. A B C D A B C D FIL E L O C A T I O N : P:\ F L \ 2 0 1 3 1 6 7 - F O R T _ P I E R C E _ H O L D I N G S _ G P _ I N C \ 2 5 - 1 1 3 - M O V E D 2 0 1 3 1 6 7 I N D R I O C R E E K - S E M I N O L E R O A D - 1 2 7 - A C R E S \ E N G I N E E R I N G \ A U T O C A D \ D W G S \ 2 5 - 1 1 3 R 2 9 . D W G , 20 2 6 . 0 6 . 2 9 , 10 : 3 0 A M CERTIFICATE OF AUTHORIZATION No. 1234567 HALEY WARD ENGINEERING ENVIRONMENTAL SURVEYING WWW.HALEYWARD.COM LAND PLANNING INTERIOR DESIGN LOT TYPICALS 6/29/2026 AS SHOWN JJL/RAH JJL/MAS MDL 25-113 R29.DWG LOT TYP C.O.A. No. DESCRIPTION BY CHK.DATE DRAWING ISSUE STATUS REV. 6-16-2026 RESPONSE TO ST. LUCIE COUNTY COMMENTS RAH MDL 1 1 10250 SW VILLAGE PARKWAY - SUITE 201 PORT SAINT LUCIE, FL 34987 ' 772-462-2455 (DATE) THE CLUB AT INDRIO CREEK ST. LUCIE COUNTY, FLORIDA CLUBHOUSE LAYOUT SCALE:1"=10' 153' 90' 10' 21' 22' 22' ALLEY 22' 90' 5' *16' RECESSED GARAGE REQUIRED FOR 50' & 60' WIDE LOTS OR CONSISTENT WITH TVC TEXT LANGUAGE. NOTES: 1.)TO PROVIDE A VARIED STREETSCAPE 50' AND 60' LOTS ARE INTERMIXED WITHIN THE NEIGHBORHOOD. 2.)GARAGE DOORS AND DRIVEWAYS SHALL NOT COMPRISE MORE THAN 50% OF THE LOT WIDTH.TYPICAL TOWNHOUSE LOT LAYOUT SCALE: 1"=40' 2' 2'5'4' SIDEWALK 1' FLUSH HEADER CURB Page 75 of 456 10250 Village Parkway, Suite 201 Port Saint Lucie, Florida 34987 772.462.2455930 S. Harbor City Blvd, Suite 506Melbourne, FL 32901321.280.9969 1234567 PROJECT TITLE DATE SCALE DRAWN BY DESIGNED BY CHECKED BY PROJECT No. DRAWING No.REV. A B C D A B C D FIL E L O C A T I O N : P:\ F L \ 2 0 1 3 1 6 7 - F O R T _ P I E R C E _ H O L D I N G S _ G P _ I N C \ 2 5 - 1 1 3 - M O V E D 2 0 1 3 1 6 7 I N D R I O C R E E K - S E M I N O L E R O A D - 1 2 7 - A C R E S \ E N G I N E E R I N G \ A U T O C A D \ D W G S \ 2 5 - 1 1 3 R 2 9 . D W G , 20 2 6 . 0 6 . 2 9 , 10 : 3 0 A M CERTIFICATE OF AUTHORIZATION No. 1234567 HALEY WARD ENGINEERING ENVIRONMENTAL SURVEYING WWW.HALEYWARD.COM LAND PLANNING INTERIOR DESIGN LANDSCAPE TYPICALS 6/29/2026 AS SHOWN JJL/RAH JJL/MAS MDL 25-113 R29.DWG LP TYP C.O.A. No. DESCRIPTION BY CHK.DATE DRAWING ISSUE STATUS REV. 6-16-2026 RESPONSE TO ST. LUCIE COUNTY COMMENTS RAH MDL 1 1 10250 SW VILLAGE PARKWAY - SUITE 201 PORT SAINT LUCIE, FL 34987 ' 772-462-2455 (DATE) THE CLUB AT INDRIO CREEK ST. LUCIE COUNTY, FLORIDA Page 76 of 456 GARA G E 11'-4 " x 2 0 ' - 1 " GARAG E 11'-4" x 2 0 ' - 1 " 2 CA R GARA G E 19'-8" x 2 0 ' - 1 " GARA G E 11'-4 " x 2 0 ' - 1 " GARAG E 11'-4" x 2 0 ' - 1 " 2 CAR GARA G E 19'-8 " x 2 0 ' - 1 " RESTORED HABITAT: (2 DU/ACRE)765,592 S.F. RESTORED HABITAT: (1 DU/ACRE)338,784 S.F. INTERIOR COUNTRYSIDE:658,509 S.F. FLOW WAY: (2 DU/ACRE)698,035 S.F. LITTORAL: (2 DU/ACRE)148,300 S.F. INTERIOR LAKES/SWALES PARK 287,501 S.F. EMERSON ROW DEDICATION: 130,007 S.F. SPINE ROW DEDICATION: 226,199 S.F. LME: (2 DU/ACRE)164,454 S.F. CIVIC BUILDING LOT 23,530 S.F. TOWNHOUSE LOT 568,338 S.F. SINGLE FAMILY LOT 908666 S.F. INTERIOR ROAD RIGHT OF WAY 589,548 S.F. E - T O B E- T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - C E E-C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-T O B E - T O B E - T O B E - T O B E - T O B E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E - C E E - C E E - C E E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E - T O B E - T O B E-TOB E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E - C E E - C E E - C E E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O B E - T O B SE M I N O L E R O A D EM E R S O N A V E FP F W C D FP F W C D FP F W C D PR O P O S E D E M E R S O N 8 0 ' R . O . W . DE D I C A T I O N N0 ° 3 5 ' 0 6 . 7 4 " E 80 . 9 3 5 L=1419.787,R=1608.000 D=50.5894 L=1379.595,R=1528.000 D=51.7310 N89° 57' 23.02"E 58.448 L=1348.435,R=1528.000 D=50.5626 L=1451.825, R=1608.000 D=51.7310 N89° 57' 23.02"E 60.006 PROPOSED LAKE 53,235 S.F. PROPOSED LAKE 88,967 S.F. PROPOSED FLOW WAY 698,035 S.F. 2 DU/ACRE LINE 1 DU/ACRE LINE P - T O B P-TOB P-TOB P-TOB P-TOB P - T O B P-T O B P-TOB P - C E P-CE P-CE P-CE P-CE P - C E P-CE P-CE PROPOSED R.O.W. DRAINAGE AREA 72,247 S.F. SITE BENCHMARK #1 SET IRON ROD ELEVATIONS 19.20' SITE BENCHMARK #2 SET IRON ROD ELEVATIONS 20.43' COUNTRYSIDE COUNTRYSIDE P-TO B P- T O B P-TOB P-TOB P-CE P-CE P- C E P- C E P-CE P-CE P-CE E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E P - T O B P - T O E PRO P E R T Y A P P R A I S E R BOU N D A R Y 120'50'120'22' ALLEY 80' R.O . W . 50' 9 0 ' ( T Y P ) 18 9 . 2 ' 200.3' 47 4 . 5 ' 298' P - T O E P - T O E P - T O E E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B FL O W W A Y 3. 4 ' 80 . 0 ' 4. 3 ' TYPICAL TOWNHOUSE LOT LAYOUTSCALE: 1"=40' A A B R25.00'CIVI C BUIL D I N G LOT PROPOSED BOX CULVERT 15' 15' CIVI C BUIL D I N G LOT PROPOSED LIFT STATION P - T O B P - T O B P - T O B P - T O B P- T O B P-CE P - C E P - C E P- C E P- C E P - C E P - C E P - C E P - T O B P - T O B P - T O B P - T O B P - T O B P - T O B P - T O B P - T O B P - T O B P - T O B P - T O B P - T O B P - T O B GAR A G E 11'-4 " x 2 0 ' - 1 " GAR A G E 11'-4 " x 2 0 ' - 1 " 2 CA R GAR A G E 19'-8 " x 2 0 ' - 1 " GAR A G E 11'-4 " x 2 0 ' - 1 " GAR A G E 11'-4 " x 2 0 ' - 1 " 2 CA R GAR A G E 19'-8 " x 2 0 ' - 1 " GARA G E 11'-4" x 2 0 ' - 1 " GAR A G E 11'-4" x 2 0 ' - 1 " 2 CARGARAG E 19'-8" x 2 0 ' - 1 " GARA G E 11'-4" x 2 0 ' - 1 " GARAG E 11'-4" x 2 0 ' - 1 " 2 CA R GARA G E 19'-8" x 2 0 ' - 1 " GARAG E 11'-4" x 2 0 ' - 1 " GARA G E 11'-4 " x 2 0 ' - 1 " 2 CARGARAG E 19'-8" x 2 0 ' - 1 " GARAG E 11'-4" x 2 0 ' - 1 " GARAG E 11'-4" x 2 0 ' - 1 " 2 CARGARAG E 19'-8" x 2 0 ' - 1 " GARAG E 11'-4" x 2 0 ' - 1 " GARA G E 11'-4 " x 2 0 ' - 1 " 2 CAR GAR A G E 19'-8" x 2 0 ' - 1 " GARAG E 11'-4" x 2 0 ' - 1 " GARA G E 11'-4" x 2 0 ' - 1 " 2 CARGARAG E 19'-8" x 2 0 ' - 1 " GARAG E 11'-4" x 2 0 ' - 1 " GARA G E 11'-4" x 2 0 ' - 1 " 2 CAR GARA G E 19'-8 " x 2 0 ' - 1 " GARAG E 11'-4" x 2 0 ' - 1 " GARA G E 11'-4 " x 2 0 ' - 1 " 2 CARGARAG E 19'-8" x 2 0 ' - 1 " GARA G E 11'-4" x 2 0 ' - 1 " GARAG E 11'-4" x 2 0 ' - 1 " 2 CA R GARA G E 19'-8 " x 2 0 ' - 1 " GAR A G E 11'-4" x 2 0 ' - 1 " GARA G E 11'-4" x 2 0 ' - 1 " 2 CAR GARA G E 19'-8" x 2 0 ' - 1 " P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-T O B P - T O B P - T O B P-TOB P-TO B P- T O B P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB GA R A G E 11' - 4 " x 2 0 ' - 1 " GA R A G E 11'- 4 " x 2 0 ' - 1 " 2 C A R GA R A G E 19'- 8 " x 2 0 ' - 1 " GA R A G E 11' - 4 " x 2 0 ' - 1 " GA R A G E 11'- 4 " x 2 0 ' - 1 " 2 C A R GA R A G E 19'- 8 " x 2 0 ' - 1 " GARAGE11'-4" x 20'-1" GARAGE11'-4" x 20'-1"2 CARGARAGE19'-8" x 20'-1"GARAGE11'-4" x 20'-1"GARAGE11'-4" x 20'-1" 2 CARGARAGE19'-8" x 20'-1" GARA G E 11'-4" x 2 0 ' - 1 " GARAG E 11'-4" x 2 0 ' - 1 " 2 CARGARAG E 19'-8" x 2 0 ' - 1 " GARA G E 11'-4" x 2 0 ' - 1 " GARAG E 11'-4" x 2 0 ' - 1 " 2 CA R GARA G E 19'-8" x 2 0 ' - 1 " GARAG E 11'-4" x 2 0 ' - 1 " GARA G E 11'-4 " x 2 0 ' - 1 " 2 CARGARAG E 19'-8" x 2 0 ' - 1 " GARAG E 11'-4" x 2 0 ' - 1 " GARAG E 11'-4" x 2 0 ' - 1 " 2 CARGARAG E 19'-8" x 2 0 ' - 1 " GARAG E 11'-4" x 2 0 ' - 1 " GARA G E 11'-4 " x 2 0 ' - 1 " 2 CARGARAG E 19'-8" x 2 0 ' - 1 " GARAG E 11'-4" x 2 0 ' - 1 " GAR A G E 11'-4" x 2 0 ' - 1 " 2 CARGARAG E 19'-8" x 2 0 ' - 1 " GARAGE11'-4" x 20'-1" GARAGE11'-4" x 20'-1"2 CARGARAGE19'-8" x 20'-1"GARAGE11'-4" x 20'-1"GARAGE11'-4" x 20'-1" 2 CARGARAGE19'-8" x 20'-1"GARAGE11'-4" x 20'-1" GARAGE11'-4" x 20'-1"2 CARGARAGE19'-8" x 20'-1"GARAGE11'-4" x 20'-1"GARAGE11'-4" x 20'-1" 2 CARGARAGE19'-8" x 20'-1"GARAGE11'-4" x 20'-1" GARAGE11'-4" x 20'-1"2 CARGARAGE19'-8" x 20'-1"GARAGE11'-4" x 20'-1"GARAGE11'-4" x 20'-1" 2 CARGARAGE19'-8" x 20'-1"GARAGE11'-4" x 20'-1" GARAGE11'-4" x 20'-1"2 CARGARAGE19'-8" x 20'-1"GARAGE11'-4" x 20'-1"GARAGE11'-4" x 20'-1" 2 CARGARAGE19'-8" x 20'-1"GARAGE11'-4" x 20'-1" GARAGE11'-4" x 20'-1"2 CARGARAGE19'-8" x 20'-1"GARAGE11'-4" x 20'-1"GARAGE11'-4" x 20'-1"2 CARGARAGE19'-8" x 20'-1" GARAGE11'-4" x 20'-1" GARAGE11'-4" x 20'-1"2 CARGARAGE19'-8" x 20'-1" GARAGE11'-4" x 20'-1"GARAGE11'-4" x 20'-1"2 CARGARAGE19'-8" x 20'-1"GARAGE11'-4" x 20'-1"GARAGE11'-4" x 20'-1"2 CARGARAGE19'-8" x 20'-1"GARAGE11'-4" x 20'-1"GARAGE11'-4" x 20'-1"2 CARGARAGE19'-8" x 20'-1" GARAGE11'-4" x 20'-1" GARAGE11'-4" x 20'-1"2 CARGARAGE19'-8" x 20'-1" GARAGE11'-4" x 20'-1"GARAGE11'-4" x 20'-1" 2 CARGARAGE19'-8" x 20'-1" GARA G E 11'-4" x 2 0 ' - 1 " GARA G E 11'-4" x 2 0 ' - 1 " 2 CAR GARA G E 19'-8" x 2 0 ' - 1 " GARA G E 11'-4" x 2 0 ' - 1 " GARA G E 11'-4" x 2 0 ' - 1 " 2 CAR GARA G E 19'-8" x 2 0 ' - 1 " B CIVI C BUIL D I N G LOT 17.58 AC. 7.78 AC. 15.12 AC. 16.02 AC. 3.40 AC. 6.60 AC. 2.98 AC. 5.19 AC. 3.78 AC. 0.54 AC. 13.05 AC. 20.86 AC. 13.53 AC. E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E - C E E-TOB E-TOB E-CE E-CE E-TOE E-TOE GAR A G E 11'-4 " x 2 0 ' - 1 " GAR A G E 11'- 4 " x 2 0 ' - 1 " 2 CA R GAR A G E 19'-8 " x 2 0 ' - 1 " GAR A G E 11'-4 " x 2 0 ' - 1 " GAR A G E 11'- 4 " x 2 0 ' - 1 " 2 CA R GAR A G E 19'- 8 " x 2 0 ' - 1 " GA R A G E 11 ' - 4 " x 2 0 ' - 1 " GA R A G E 11 ' - 4 " x 2 0 ' - 1 " 2 C A R GA R A G E 19' - 8 " x 2 0 ' - 1 " GA R A G E 11 ' - 4 " x 2 0 ' - 1 " GA R A G E 11 ' - 4 " x 2 0 ' - 1 " 2 C A R GA R A G E 19' - 8 " x 2 0 ' - 1 " GAR A G E 11'-4 " x 2 0 ' - 1 " GAR A G E 11'-4 " x 2 0 ' - 1 " 2 CA R GAR A G E 19'-8 " x 2 0 ' - 1 " GAR A G E 11'-4 " x 2 0 ' - 1 " GAR A G E 11'-4 " x 2 0 ' - 1 " 2 CA R GAR A G E 19'-8 " x 2 0 ' - 1 " GARAG E 11'-4" x 2 0 ' - 1 " GARAG E 11'-4" x 2 0 ' - 1 " 2 CARGARAG E 19'-8" x 2 0 ' - 1 " GARAG E 11'-4" x 2 0 ' - 1 " GARAG E 11'-4" x 2 0 ' - 1 " 2 CARGARAG E 19'-8" x 2 0 ' - 1 " GARAGE 11'-4" x 20'-1 " GARAGE 11'-4" x 20'- 1 " 2 CARGARAGE 19'-8" x 2 0 ' - 1 " GARAGE 11'-4" x 20'- 1 " GARAGE 11'-4" x 20'-1 " 2 CARGARAGE 19'-8" x 20' - 1 " GA R A G E 11 ' - 4 " x 2 0 ' - 1 " G A R A G E 11 ' - 4 " x 2 0 ' - 1 " 2 C A R G A R A G E 19 ' - 8 " x 2 0 ' - 1 " G A R A G E 11 ' - 4 " x 2 0 ' - 1 " GA R A G E 11 ' - 4 " x 2 0 ' - 1 " 2 C A R GA R A G E 19 ' - 8 " x 2 0 ' - 1 " GARAGE 11'-4" x 2 0 ' - 1 " GARAGE 11'-4" x 20 ' - 1 " 2 CARGARAGE 19'-8" x 20'-1" GARAGE 11'-4" x 2 0 ' - 1 " GARAGE 11'-4" x 20' - 1 " 2 CARGARAGE 19'-8" x 20'-1 " GARA G E 11'-4" x 2 0 ' - 1 " GARA G E 11'-4" x 2 0 ' - 1 " 2 CARGARAG E 19'-8" x 2 0 ' - 1 " GARAG E 11'-4" x 2 0 ' - 1 " GARAG E 11'-4" x 2 0 ' - 1 " 2 CAR GARAG E 19'-8" x 2 0 ' - 1 " GA R A G E 11 ' - 4 " x 2 0 ' - 1 " GA R A G E 11' - 4 " x 2 0 ' - 1 " 2 C A R GA R A G E 19' - 8 " x 2 0 ' - 1 " GA R A G E 11' - 4 " x 2 0 ' - 1 " GA R A G E 11' - 4 " x 2 0 ' - 1 " 2 C A R GA R A G E 19 ' - 8 " x 2 0 ' - 1 " GARAG E 11'-4" x 2 0 ' - 1 " GARA G E 11'-4" x 2 0 ' - 1 " 2 CARGARAG E 19'-8" x 2 0 ' - 1 " GARA G E 11'-4" x 2 0 ' - 1 " GARAG E 11'-4" x 2 0 ' - 1 " 2 CA R GARA G E 19'-8" x 2 0 ' - 1 " GARAGE11'-4" x 20'-1" GARAGE11'-4" x 20'-1" 2 CARGARAGE19'-8" x 20'-1" GARAGE11'-4" x 20'-1" GARAGE11'-4" x 20'-1" 2 CARGARAGE19'-8" x 20'-1" GARAGE11'-4" x 20'-1" GARAGE11'-4" x 20'-1" 2 CARGARAGE19'-8" x 20'-1" GARAGE11'-4" x 20'-1" GARAGE11'-4" x 20'-1" 2 CARGARAGE19'-8" x 20'-1" GARAGE11'-4" x 20'-1"GARAGE11'-4" x 20'-1"2 CARGARAGE19'-8" x 20'-1" GARAGE11'-4" x 20'-1"GARAGE11'-4" x 20'-1" 2 CAR GARAGE19'-8" x 20'-1" GARAGE11'-4" x 20'-1" GARAGE11'-4" x 20'-1"2 CARGARAGE19'-8" x 20'-1" GARAGE11'-4" x 20'-1"GARAGE11'-4" x 20'-1" 2 CARGARAGE19'-8" x 20'-1" GARAGE11'-4" x 20'-1" GARAGE11'-4" x 20'-1" 2 CARGARAGE19'-8" x 20'-1" GARAGE11'-4" x 20'-1" GARAGE11'-4" x 20'-1" 2 CARGARAGE19'-8" x 20'-1" GARAGE11'-4" x 20'-1" GARAGE11'-4" x 20'-1" 2 CARGARAGE19'-8" x 20'-1" GARAGE11'-4" x 20'-1" GARAGE11'-4" x 20'-1" 2 CARGARAGE19'-8" x 20'-1" GARAGE11'-4" x 20'-1" GARAGE11'-4" x 20'-1"2 CARGARAGE19'-8" x 20'-1"GARAGE11'-4" x 20'-1"GARAGE11'-4" x 20'-1" 2 CARGARAGE19'-8" x 20'-1" GARAGE11'-4" x 20'-1" GARAGE11'-4" x 20'-1"2 CARGARAGE19'-8" x 20'-1"GARAGE11'-4" x 20'-1"GARAGE11'-4" x 20'-1" 2 CARGARAGE19'-8" x 20'-1" 75 ' 35 ' 35' 75' 106 ' 20 ' 12 9 ' 20 ' 10 0 ' 131' 35 ' 35' 47 ' 35 ' 35' 20' 11 0 ' 20 ' 35' 20 ' 6 2 ' 20' 10' 20' 20' L.M.E. & UPLAND BUFFER 25 7 ' 30 4 ' 68 ' 151' 60 ' 241'27 2 ' 88 ' 85' 26 ' 20 ' GAR A G E 11'-4 " x 2 0 ' - 1 " GAR A G E 11'-4 " x 2 0 ' - 1 " 2 CA R GAR A G E 19'-8 " x 2 0 ' - 1 " GAR A G E 11'- 4 " x 2 0 ' - 1 " GAR A G E 11'-4 " x 2 0 ' - 1 " 2 CA R GAR A G E 19'-8 " x 2 0 ' - 1 " GARA G E 11'-4" x 2 0 ' - 1 " GARAG E 11'-4" x 2 0 ' - 1 " 2 CAR GARA G E 19'-8" x 2 0 ' - 1 " GARAG E 11'-4" x 2 0 ' - 1 " GARAGE 11'-4" x 2 0 ' - 1 " 2 CAR GARAG E 19'-8" x 2 0 ' - 1 " 92 ' 22' A L L E Y 120' icrosoft Corporation © 2025 Maxar ©CNES (2025) Distribution Airbus DS © 2025 TMAP MOBILITY Earthstar Geographics SIO VICINITY MAP SCALE: 1:1,000 EXISTING METER PROPOSED MITERED END SECTION PROPOSED SIGN HANDICAP PARKING SYMBOL EXISTING CONCRETE EXISTING PAVEMENT EXISTING UTILITY POLE EXIST. DRAINAGE INLET EXISTING STREET LIGHT PROPOSED LIGHT POLE (SINGLE) DRAINAGE FLOW ARROW PROPOSED LIGHT POLE (DOUBLE) PARKING STALL COUNT PROPOSED CONCRETE PROPOSED DRAINAGE INLET EXISTING DRAINAGE PROPOSED DRAINAGE PIPE VERTICAL DATUM NOTE: ELEVATIONS SHOWN HEREON ARE RELATIVE TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (N.A.V.D.88) AND ARE GIVEN IN U.S. SURVEY FEET UNLESS OTHERWISE NOTED. *GENERAL ACCEPTED CONVERSION: NAVD + 1.475 = NGVD NOTE: THE PROPERTY OWNER, CONTRACTOR, AND AUTHORIZED REPRESENTATIVES SHALL PROVIDE PICKUP, REMOVAL, AND DISPOSAL OF LITTER WITHIN THE PROJECT LIMITS AND SHALL BE RESPONSIBLE FOR MAINTENANCE OF THE AREA FROM THE EDGE OF PAVEMENT TO THE PROPERTY LINE WITHIN THE RIGHT-OF-WAY PROPOSED PAVEMENT SITE # F.I.R.M. PANEL: xxx ST. LUCIE COUNTY UNINCORPORATED AREA 120285 ZONE X ( IN FEET ) GRAPHIC SCALE 0150 75 150 300 450 1 inch = 150 ft. 10250 Village Parkway, Suite 201 Port Saint Lucie, Florida 34987 772.462.2455930 S. Harbor City Blvd, Suite 506Melbourne, FL 32901321.280.9969 1234567 PROJECT TITLE DATE SCALE DRAWN BY DESIGNED BY CHECKED BY PROJECT No. DRAWING No.REV. A B C D A B C D FIL E L O C A T I O N : P:\ F L \ 2 0 1 3 1 6 7 - F O R T _ P I E R C E _ H O L D I N G S _ G P _ I N C \ 2 5 - 1 1 3 - M O V E D 2 0 1 3 1 6 7 I N D R I O C R E E K - S E M I N O L E R O A D - 1 2 7 - A C R E S \ E N G I N E E R I N G \ A U T O C A D \ D W G S \ 2 5 - 1 1 3 R 2 9 . D W G , 20 2 6 . 0 6 . 2 9 , 10 : 3 1 A M CERTIFICATE OF AUTHORIZATION No. 1234567 HALEY WARD ENGINEERING ENVIRONMENTAL SURVEYING WWW.HALEYWARD.COM LAND PLANNING INTERIOR DESIGN PRELIMINARY ENGINEERING PLAN 6/29/2026 AS SHOWN JJL/RAH JJL/MAS MDL 25-113 R29.DWG PEP C.O.A. No. DESCRIPTION BY CHK.DATE DRAWING ISSUE STATUS REV. Know what's below. Call before you dig. www.callsunshine.com It's fast. It's free. It's the law. 10250 SW VILLAGE PARKWAY - SUITE 201 PORT SAINT LUCIE, FL 34987 ' 772-462-2455 (DATE) THE CLUB AT INDRIO CREEK ST. LUCIE COUNTY, FLORIDA DESCRIPTION WETLANDS RARE HABITAT THREATENED SPECIES ENDANGERED SPECIES SPECIES OF SPECIAL CONCERN INVASIVE/EXOTIC VEGETATION FOUND (YES/NO) AGENCY CONTACT INFORMATION MANAGEMENT PLAN (YES/NO) RELOCATION PLAN (YES/NO) -- NOTE: PLEASE REFER TO THE ENVIRONMENTAL ASSESSMENT COMPLETED BY XX ON DATED. ENVIRONMENTAL SITE ASSESSMENT STATEMENT -- -- -- -- -- VICINITY MAP SCALE: 1:1,000 SITE DATA LEGAL DESCRIPTION 1314-323-0002-000-3 14 34 39 S 1/2 OF NW 1/4 OF SW 1/4-LESS N 170 FT AND LESS CANAL AND RD RS/W (15.42 AC) 1314-313-0000-000-8 14 34 39 S 1/2 OF NE 1/4 OF SW 1/4-LESS N 208.71 FT OF E 208.71 FT AND LESS RD AND CANAL RS/W- (18.13 AC) 1314-331-0001-000-1 14/23 34 39 FROM SW COR SEC 14 RUN N 89 DEG 30 MIN 19 SEC E ALG S LI OF SEC 48 FT TO E R/W LI EMERSON AV AND POB, TH N 00 DEG 07 MIN 22 SEC E ALG SD E R/W 1311.43 FT TO C/L OF DITCH, TH N 89 DEG 49 MIN 59 SEC E ALG C/L 1218.78 FT, TH S 45 DEG 07 MIN 23 SEC E 46.22 FT, TH S 00 DEG 35 MIN 00 SEC W 1472.61 FT TO S LI OF N 6.18 AC OF NW 1/4 OF NW 1/4 OF SEC 23, TH S 89 DEG 30 MIN 19 SEC W 1239.97 FT TO E R/W EMERSON AV, TH N 00 DEG 10 MIN 00 SEC E 200.88 FT TO POB (43.14 AC) 1314-342-0001-000-5 14/23 34 39 W 1/2 OF SE 1/4 OF SW 1/4 AND N 230 FT OF NW 1/4 OF NE 1/4 OF NW 1/4 (24.72 AC) 1323-211-0005-000-8 23 34 39 N 3/4 OF N 1/2 OF NE 1/4 OF NW 1/4-LESS N 230 FT AND LESS E 90 FT (7.93 AC) PARCEL ID #: 1314-323-0002-000-3 1314-313-0000-000-8 1314-331-0001-000-1 1314-342-0001-000-5 1323-211-0005-000-8 PROJECT NAME: THE CLUB AT INDRIO CREEK OWNERSHIP:BRINDHAVANAM LLC 4528 SHILOH MILL BLVD JACKSONVILLE, FL 32246-1877 FUTURE LAND USE: TVC ZONING: AG-1 LAND SIZE:5,533,381 S.F. (127.03 AC) BUILDING DATA GROSS SQUARE FOOTAGE 408 UNITS PROPOSED SINGLE FAMILY 212 UNITS 40'S 110 UNITS 50'S 102 UNITS PROPOSED TOWNHOMES 196 UNITS PROVIDER OF UTILITIES: WATER: FPUA WASTEWATER: FPUA IRRIGATION: N/A SOLID WASTE: ROLL OUT AND DUMPSTER AUTHORIZED STORMWATER DRAINAGE: THE SURFACE WATER MANAGEMENT SYSTEM FOR THE PROJECT WILL COLLECT SITE RUNOFF IN A SERIES OF INLETS WHICH WILL CONVEY THE RUNOFF TO OFFSITE DRAINAGE AREA SOLID WASTE: BASED ON THE INTENDED USE OF THE BUILDING, THIS PROJECT WILL UTILIZE A DUMPSTER AREA FOR SOLID WASTE AND RECYCLABLE ITEMS. HAZARDOUS WASTE: ANY AND ALL HAZARDOUS OR TOXIC MATERIALS GENERATED OR USED OR STORED ON SITE SHALL BE DISPOSED OF IN ACCORDANCE WITH ALL LOCAL, STATE AND FEDERAL REGULATIONS. LANDSCAPE: REFER TO LANDSCAPE PLAN BY OTHERS. (NO PLANS AVAILABLE) ACCESSIBILITY AND ADA COMPLIANCE: ALL SIDEWALKS AND RAMPS WILL MEET FDOT AND ADA REQUIREMENTS. F.I.R.M. PANEL: 12111C0070J ST. LUCIE COUNTY UNINCORPORATED AREA 120285 ZONE X SE M I N O L E R O A D EM E R S O N A V E RESTORED HABITAT R.O.W. DEDICATION ZONING CODE FOR: AG-1 (AGRICULTURAL - 1) YARD SETBACKS BUILDING BUILDING FRONT REAR SIDE CORNER COVERAGE HEIGHT PER CODE PROPOSED 50'30'20'30'20(j)% MAX.80(j)' MAX. 55'40 X X X%X' COUNTRYSIDE Page 77 of 456 E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE 1314-323-0001-000-6 Russakis Investments LLC EXISTING TOWER SITE EMERSON AVENUE S. R . 6 1 4 I N D R I O R O A D 1315-411-0001-000-9 E2M PROPERTIES OF FLORIDA 1315-411-0001-010-2 STATE OF FLORIDA DOT 1315-111-0001-000-8 FPFWCD PROPERTY APPRAISER BOUNDARY PROPERTY APPRAISER BOUNDARY EXISTING RIP RAP 90 . 0 ' 50 . 5 ' 50 . 5 ' 13 3 . 0 ' E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E - T O B E-TOB SIGN MAST ARM TRAFFIC SIGNAL ASPHALT DRIVE 5'5' 85' ASPHALT ROAD DIRT ROADEND ASPHALT ROAD F.P.F.W.C.D. CANAL NO. 6 COMMUNICATION RISER EMERSON AVENUE FIBER HANDHOLE & MARKER ASPHALT DRIVE ASPHALT DRIVE CONC. WALK EXISTING 2' CURB AND GUTTER ENDS EXISTING GUARD RAILEXISTING SIGNEXISTING SIGN EXISTING CURB INLET: 21.83'EXISTING CURB INLET: 21.32' SITE BENCHMARK FND NAIL & DISK N:1158673' E:845781' ELEV:21.37' EXISTING AT&T HANDHOLE EXISTING MAST ARM TRAFFIC SIGNAL EXISTING HAND RAIL EXISTING PEDESTRIAN SIGNAL EXISTING CURB INLET: 21.85' 1314-322-0010-000-9 FPFWCD E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - C E E - C E E - C E E - C E E - C E E - T O E E - T O E E - T O E E - T O E DIRT ROAD © 2025 Microsoft Corporation © 2025 Maxar ©CNES (2025) Distribution Airbus DS © 2025 TMAP MOBILITY Earthstar Geographics SIO E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E - T O B E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-C E E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE N0° 35' 06.74"E 80.935 E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE 1314-323-0001-000-6 Russakis Investments LLC EXISTING TOWER SITE EMERSON AVENUE P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOE P-TOE P-TOE P-TOE P-TOE P-TOE P-TOE P-TOE P-TOE P-TOE EXISTING DIRT ROAD EXISTING DITCH (TO REMAIN) PROPOSED THE CLUB @ INDIAN CREEK ENTRANCE EXISTING DIRT ROAD PROPOSED ACCESS TO EXISTING DIRT ROAD RECONFIGURED DITCHPROPOSED STOP SIGN AND STOP BAR PROPOSED PEDESTRIAN CROSSWALK 43 . 0 ' 80 . 0 ' 43 . 0 ' PR O P O S E D 80 . 0 ' R . O . W . D E D I C A T I O N 43 . 0 ' 29 . 0 ' R 8 5 0 . 0 ' 12 . 0 ' 12 . 0 ' 2. 0 ' TRANSITION TO THE EXISTING DIRT ROAD E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB E-TOB 90'90'90' FIBER HANDHOLE & MARKER RUSSAKIS INVESTMENTS LLC Parcel ID: 1314-323-0001-000-6 N 170 FT OF S 1/2 OF NW 1/4 OF SW 1/4-LESS CANAL AND RD RW DIRT ROAD DIRT ROAD DIRT ROAD F.P.F.W.C.D. CANAL NO. 6 90 . 0 ' SITE BENCHMARK FND NAIL & DISK N:1157674' E:845786' ELEV:20.38' 1314-322-0010-000-9 FPFWCD 12 . 0 ' 12 . 0 ' 5. 0 ' 3. 0 ' 5. 0 ' 3. 0 ' A A B 231' TRANSITION F R O M 1 2 ' W I D E L A N E S T O 1 0 ' W I D E R8 2 0 . 0 ' P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P - T O B P- T O B P- T O B P-T O B P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TO B P-T O B B 5' 2. 0 ' 6. 0 ' 4' T O M A T C H EX . G R A D E E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E-CE E - T O B E - T O B E - T O B E - T O B E - T O B E - C E E - C E E - C E E - C E E - C E E - T O E E - T O E E - T O E VICINITY MAP EXISTING METER PROPOSED MITERED END SECTION PROPOSED SIGN HANDICAP PARKING SYMBOL EXISTING CONCRETE EXISTING PAVEMENT EXISTING UTILITY POLE EXIST. DRAINAGE INLET EXISTING STREET LIGHT PROPOSED LIGHT POLE (SINGLE) DRAINAGE FLOW ARROW PROPOSED LIGHT POLE (DOUBLE) PARKING STALL COUNT PROPOSED CONCRETE PROPOSED DRAINAGE INLET EXISTING DRAINAGE PROPOSED DRAINAGE PIPE VERTICAL DATUM NOTE: ELEVATIONS SHOWN HEREON ARE RELATIVE TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (N.A.V.D.88) AND ARE GIVEN IN U.S. SURVEY FEET UNLESS OTHERWISE NOTED. *GENERAL ACCEPTED CONVERSION: NAVD + 1.475 = NGVD NOTE: THE PROPERTY OWNER, CONTRACTOR, AND AUTHORIZED REPRESENTATIVES SHALL PROVIDE PICKUP, REMOVAL, AND DISPOSAL OF LITTER WITHIN THE PROJECT LIMITS AND SHALL BE RESPONSIBLE FOR MAINTENANCE OF THE AREA FROM THE EDGE OF PAVEMENT TO THE PROPERTY LINE WITHIN THE RIGHT-OF-WAY PROPOSED PAVEMENT # ( IN FEET ) GRAPHIC SCALE 030 15 30 60 90 1 inch = 30 ft. 10250 Village Parkway, Suite 201 Port Saint Lucie, Florida 34987 772.462.2455930 S. Harbor City Blvd, Suite 506Melbourne, FL 32901321.280.9969 1234567 PROJECT TITLE DATE SCALE DRAWN BY DESIGNED BY CHECKED BY PROJECT No. DRAWING No.REV. A B C D A B C D FIL E L O C A T I O N : P:\ F L \ 2 0 1 3 1 6 7 - F O R T _ P I E R C E _ H O L D I N G S _ G P _ I N C \ 2 5 - 1 1 3 - M O V E D 2 0 1 3 1 6 7 I N D R I O C R E E K - S E M I N O L E R O A D - 1 2 7 - A C R E S \ E N G I N E E R I N G \ A U T O C A D \ D W G S \ 2 5 - 1 1 3 R 2 9 . D W G , 20 2 6 . 0 6 . 2 9 , 10 : 3 1 A M CERTIFICATE OF AUTHORIZATION No. 1234567 HALEY WARD ENGINEERING ENVIRONMENTAL SURVEYING WWW.HALEYWARD.COM LAND PLANNING INTERIOR DESIGN EMERSON AVENUE ROADWAY EXHIBIT 6/29/2026 AS SHOWN JJL/RAH JJL/MAS MDL 25-113 R29.DWG EMERSON C.O.A. No. DESCRIPTION BY CHK.DATE DRAWING ISSUE STATUS REV. 6-16-2026 RESPONSE TO ST. LUCIE COUNTY COMMENTS RAH MDL 1 1 Know what's below. Call before you dig. www.callsunshine.com It's fast. It's free. It's the law. 10250 SW VILLAGE PARKWAY - SUITE 201 PORT SAINT LUCIE, FL 34987 ' 772-462-2455 (DATE) THE CLUB AT INDRIO CREEK ST. LUCIE COUNTY, FLORIDA DESCRIPTION WETLANDS RARE HABITAT THREATENED SPECIES ENDANGERED SPECIES SPECIES OF SPECIAL CONCERN INVASIVE/EXOTIC VEGETATION FOUND (YES/NO) AGENCY CONTACT INFORMATION MANAGEMENT PLAN (YES/NO) RELOCATION PLAN (YES/NO) -- NOTE: PLEASE REFER TO THE ENVIRONMENTAL ASSESSMENT COMPLETED BY XX ON DATED. ENVIRONMENTAL SITE ASSESSMENT STATEMENT -- -- -- -- -- VICINITY MAP SCALE: NTS SITE SE M I N O L E R O A D EM E R S O N A V E RESTORED HABITAT R.O.W. DEDICATION ZONING CODE FOR: AG-1 (AGRICULTURAL - 1) YARD SETBACKS BUILDING BUILDING FRONT REAR SIDE CORNER COVERAGE HEIGHT PER CODE PROPOSED 50'30'20'30'20(j)% MAX.80(j)' MAX. 55'40 X X X%X' INDRIO ROAD TOP BOTTOM14 6 0 ' Page 78 of 456 12' TRAVEL AISLE 12' TRAVEL AISLE SLOPE 2.0% 6'DISTANCE VARIES SIDEWALKGRASS SLOPE 2.0% CL PL PL EMERSON AVENUE SECTION A-A N.T.S. 6" MIN SUBGRADE EXTENSION TYPE F CURB SLOPE 1.5% 2'DISTANCE VARIES GRASS 5' BIKE LANE 2' TYPE F CURB 6" MIN SUBGRADE EXTENSION PROPOSED 80' RIGHT OF WAY DEDICATIION R/W R/W EMERSON AVENUE SECTION B-B N.T.S. EXISTING TOP OF BANK 43' EX. EMERSON AVENUE RIGHT OF WAY 5'± 2' F.P.F.W.C.D. CANAL NO. 6 R/W GUARDRAIL IN CONCRETE CL PL PL TYPICAL E/W 80' COLLECTOR N.T.S. PROPOSED 80' RIGHT OF WAY DEDICATIION EX. 43' R.O.W. EMERSON AVE 12' TRAVEL AISLE 6' SIDEWALK SLOPE 2.0% SLOPE 2.0% 12' MEDIAN 2'7' GRASS F CURB PL SOUTHERN FLOW WAY EDGE N.T.S. 15' LANDSCAPE BUFFER 20' UPLAND BUFFER *NOTES: 1. SIDE SLOPES ON SWALES SHALL NOT BE STEEPER THAN 4:1. 2. SOD ALL DISTURBED AREAS. 1 10 1 4 MAX. GRADE C.E. 20' LME T.O.B. 10'10' BREAK 1 10 1 4 MAX. 1 2 MAX. 20' LITTORAL SHELF GRADE BREAK GRADE BREAK GRADE BREAK 4' 12' MIN 30' MAX C.E. FLOW WAY 10' TRAVEL AISLE 21' ALLEY SLOPE 2.0% CL PL PL PROPOSED DRAINAGE SYSTEM TYPICAL 22' ALLEY STREET SECTION N.T.S. 6" MIN SUBGRADE EXTENSION 6" MIN BASE EXTENSION 10' TRAVEL AISLE 21' BRICK PAVERS SLOPE 2.0% 1' SLOPE 1' FLUSH HEADER CURB GARAGE FRONT 21' BRICK PAVERS 1' SLOPE GARAGE FRONT 12' TRAVEL AISLE 6' SIDEWALK SLOPE 2.0% SLOPE 2.0% 12' MEDIAN 2'7' GRASS F CURB 10' TRAVEL AISLE 50' 8'5' SIDEWALKGRASS SLOPE 2.0% CL PL PL 2' VALLEY GUTTER PROPOSED WATER MAIN PROPOSED GRAVITY SEWER 2' TYPICAL 50' PRIVATE RIGHT-OF-WAY SECTION N.T.S. 6" MIN SUBGRADE EXTENSION SLOPE 2.0% 10' TRAVEL AISLE 8'5' SIDEWALK GRASS SLOPE 2.0% 2' SLOPE 2.0% 2' VALLEY GUTTER 6" MIN BASE EXTENSION 6" MIN SUBGRADE EXTENSION 6" MIN BASE EXTENSION 6" MIN SUBGRADE EXTENSION 6" MIN BASE EXTENSION 0.6' 5' BIKE LANE 3' MATCH EXISTING GRADE 12' TRAVEL AISLE 12' TRAVEL AISLE SLOPE 2.0% 6' SIDEWALK SLOPE 2.0% CL 6" MIN SUBGRADE EXTENSION TYPE F CURB SLOPE 1.5% 2'4' GRASS 2' TYPE F CURB MATCH EXISTING GRADE6" MIN SUBGRADE EXTENSION 1 4 MAX.1 4 MAX. 1' 1' 10250 Village Parkway, Suite 201 Port Saint Lucie, Florida 34987 772.462.2455930 S. Harbor City Blvd, Suite 506Melbourne, FL 32901321.280.9969 1234567 PROJECT TITLE DATE SCALE DRAWN BY DESIGNED BY CHECKED BY PROJECT No. DRAWING No.REV. A B C D A B C D FIL E L O C A T I O N : P:\ F L \ 2 0 1 3 1 6 7 - F O R T _ P I E R C E _ H O L D I N G S _ G P _ I N C \ 2 5 - 1 1 3 - M O V E D 2 0 1 3 1 6 7 I N D R I O C R E E K - S E M I N O L E R O A D - 1 2 7 - A C R E S \ E N G I N E E R I N G \ A U T O C A D \ D W G S \ 2 5 - 1 1 3 R 2 9 . D W G , 20 2 6 . 0 6 . 2 9 , 10 : 3 1 A M CERTIFICATE OF AUTHORIZATION No. 1234567 HALEY WARD ENGINEERING ENVIRONMENTAL SURVEYING WWW.HALEYWARD.COM LAND PLANNING INTERIOR DESIGN CROSS SECTIONS 6/29/2026 AS SHOWN JJL/RAH JJL/MAS MDL 25-113 R29.DWG X SEC C.O.A. No. DESCRIPTION BY CHK.DATE DRAWING ISSUE STATUS REV. 6-16-2026 RESPONSE TO ST. LUCIE COUNTY COMMENTS RAH MDL 1 1 10250 SW VILLAGE PARKWAY - SUITE 201 PORT SAINT LUCIE, FL 34987 ' 772-462-2455 (DATE) THE CLUB AT INDRIO CREEK ST. LUCIE COUNTY, FLORIDA Page 79 of 456 The Club at Indrio Creek | 01-Aug-25 | 25-113 | Page 1 August 1st, 2025 Fort Pierce Holdings GP, Inc. Attn: Yoni Bornstein 92 SW 3rd Street, Unit 5211 Miami, FL 33130 ybinternational.gmail.com Re: Indrio Creek/Seminole Road - Tree Assessment & Inventory Prepared by: Anthony A. Adams International Society of Arboriculture Certified Arborist FL-9472A Certification of Performance: I, Anthony A. Adams, certify to the best of my knowledge, and abilities: That I have personally inspected the tree(s) and or the property referred to in this report. That it is my professional opinion, that the following report is true, and the conclusions and results stated are correct based on the information received about the property evaluated and the evaluation methods followed. That the reported analyses, opinions, and conclusions are only limited by the reported assumptions, methods and limiting conditions and my personal, unbiased professional analyses, opinions and conclusions. That Haley Ward, Inc. acts as an independent tree, and environmental consultant. That this Report, or parts of this Report, have not been revealed to any party other than the Client named and will not be revealed to any other party unless authorized to do so by Client named or by due process of law or by legally required public testimony by this firm of these results. This report is written in good faith, and all rights are reserved by Haley Ward, Inc. It is for use by the client named only. Signature: Date: 08/01/2025 Page 80 of 456 The Club at Indrio Creek | 01-Aug-25 | 25-113 | Page 2 I. Introduction This Report is written for Yoni Bornstein of Fort Pierce Holdings GP, Inc. It is based on information obtained from the site visit(s), to provide and assign values to the trees located on the subject property. II. Property Involved The subject property evaluated as part of this Tree Inventory consists of six (6) tax parcels comprised of 127.08 acres. The subject property is located south of Indrio Road and west of Seminole Road, in Fort Pierce, FL. Parcel ID Parcel Address Acreage Current FLU Current Zoning 1314-331-0001-000-1 Emerson Ave 43.14 TVC AG-1 1314-342-0001-000-5 Seminole Rd 24.72 TVC AG-1 1314-313-0000-000-8 Seminole Rd 18.13 TVC AG-1 1314-341-0000-000-5 Seminole Rd 17.74 TVC AG-1 1314-323-0002-000-3 Emerson Ave 15.42 TVC AG-1 1323-211-0005-000-8 Seminole Rd 7.93 TVC AG-1 TOTAL ACRES: 127.08 The subject property has a Future Land Use designation of TVC. The subject property has a zoning designation of AG-1. The subject property is further located within Section 14, Township 34 South and Range 39 East. III. Data Collection The property/trees were evaluated by site visits to determine environmental conditions. This appraisal is based on value of subject as per ISA “Rule 14-40.030, Florida Administrative Code”. See Appendix A for full tree data. IV. Limiting Conditions This “Arboriculture Report” includes only the listed trees, landscape conditions in the immediate area where the tree is located, and conditions caused by or attributable to the trees on this property. Limits of the Assignment 1. This report is not intended as and does not represent legal advice and should not be relied upon to take the place of such advice. 2. This report is limited to documenting the condition of the tree on the dates given. Care has been taken to obtain all information from reliable sources. All data has been verified insofar as possible; however, the consultant can neither guarantee nor be responsible for the accuracy of information provided by others. Page 81 of 456 The Club at Indrio Creek | 01-Aug-25 | 25-113 | Page 3 3. Loss or alteration of any part of this report invalidates the entire report. 4. Sketches and photographs used in this report are intended as visual aids only and are not necessarily to scale. V. Discussion There is a total of one hundred and twenty-three (123) native trees on the subject property that meet Saint Lucie County requirements for mitigation or preservation. The breakdown by species is as follows: Cabbage Palms: 77 Pines: 6 Oak spp: 40 VI. Conclusions and Recommendations Values are calculated for trees 12” D.B.H and greater as per Saint Lucie County code. TREES (Total D.B.H. Inches) x (2) x ($200) = Mitigation Costs - Tree Removal PALMS (Total # of Palms) x ($200) = Mitigation Costs - Palms Trees = (988.2in. DBH) x (2) x $200 = $395,280.00 Palms = (77) x $200 = $15,400.00 *Max. Mitigation Cost = $410,680.00* The calculated fee of $410,680.00 is the **maximum** tree mitigation fee that is possible – if every tree on the subject parcel was to be cleared. A site planner can use the information in this report to avoid impacts to high-value trees and preserve other trees in order to reduce mitigation costs to zero, if desired. Please see the attached Tree Table and Tree Location Map. This Report, or parts of this Report, have not been revealed to any party other than the Client named and will not be revealed to any other party unless authorized to do so by Client named or by due process of law or by legally required public testimony by this firm of these results. This report is written in good faith and all rights are reserved by Haley Ward. It is for use by the client named only. Page 82 of 456 The Club at Indrio Creek - Tree Location M ap Page 83 of 456 Environmental Impact Report (EIR) Club at Indio Creek S of Indrio Road, W of Emerson Avenue, & E of Seminole Road, Unincorporated St. Lucie County, Florida Section 14, Township 34 S, Range 39 E Parcel Identification Number (PIN) Address 1314-323-0002-000-3 Unassigned Emerson Avenue 1314-313-0000-000-8 Unassigned Seminole Road 1314-331-0001-000-1 Unassigned Emerson Avenue 1314-342-0001-000-5 Unassigned Seminole Road 1314-341-0000-000-5 Unassigned Seminole Road 1323-211-0005-000-8 Unassigned Seminole Road Prepared For: St Lucie County Environmental Resource Department Prepared By: Jennifer Acevedo ©Aquatic Research Monitoring, Equipment, and Deployment, LLC March 2026 Page 84 of 456 Club at Indrio Creek, March 2026 Page 2 of 24 TABLE OF CONTENT INTRODUCTION ........................................................................................................................................ 3 1. Vegetation and Substrate Survey ....................................................................................................... 4 2. Statement of jurisdictional control over the environmental area .................................................... 9 3. Statement on when the jurisdictional boundaries were delineated and who delineated the boundaries. ..............................................................................................................................................10 4. Indicate the required first floor elevation, and whether all floor elevations will be above this level. .........................................................................................................................................................10 5. Identification of any area that has experienced overwash of the primary dune. ..........................10 6. Identification of any area subject to breach during storm conditions. ..........................................10 7. Assessment of the impacts upon onsite vegetation and wildlife. .....................................................10 8. Assessment of the impacts upon onsite and off-site natural resources. ..........................................12 9. Detailed description of the planned approach to minimize impacts. .............................................13 10. Detailed description of the proposed alterations or disturbances being proposed......................18 11. Detailed description of the proposed mitigation plan to off set impacts. .....................................18 12. Plant and animal survey for onsite federal and state protected species. ......................................19 13. Surface water management plan and written assessment including a description of techniques to be used to prevent both the potential degradation of surface water resources and an increase in flood hazard damage. .............................................................................................................................23 14. A sea turtle protection plan. .............................................................................................................24 15. A shoreline stabilization plan. ..........................................................................................................24 16. A gopher tortoise protection plan. ...................................................................................................24 Attachment 1 Environmental Assessment with Listed Species Survey Attachment 2 Wetland Boundary Survey Attachment 3 UMAM Page 85 of 456 Club at Indrio Creek, March 2026 Page 3 of 24 INTRODUCTION The following environmental impact report has been prepared in accordance with Section 11.02.09(A) (5) of the St. Lucie County Land Development Code (LDC). The environmental impact report is required when the thresholds depicted in Section 11.02.09(A) (5) (a) are met. The Club at Indrio Creek Project is ±127.029-acres and consists of six (6) parcels. It is located south of Indrio Road/SR-614, east of Emerson Avenue, and west of Seminole Trail within unincorporated St. Lucie County Florida. Please see Attachment 1 Environmental Assessment Appendix A, Figure 1 of the enclosed for the Location Map. Map ID# Parcel Identification Number (PIN) Address 1 1314-323-0002-000-3 Unassigned Emerson Avenue 2 1314-313-0000-000-8 Unassigned Seminole Road 3 1314-331-0001-000-1 Unassigned Emerson Avenue 4 1314-342-0001-000-5 Unassigned Seminole Road 5 1314-341-0000-000-5 Unassigned Seminole Road 6 1323-211-0005-000-8 Unassigned Seminole Road Table 1.0. Parcel identification numbers, location, and acreage The site is bordered to the north and south by inactive agriculture areas followed by single family home lots and PUD style communities further to the north. The western property boundary is adjacent to an offsite ditch and Emerson Avenue. Further west is the Fort Pierce Farms Water Control District (FPFWCD) Canal No.6 and inactive agricultural lands. To the east is FPFWCD Canal No. 5 and Seminole Trail followed by inactive agriculture areas. Please see Appendix A Figure 2 of the enclosed Environmental Assessment for the Site Map. The immediate surrounding area (±2 miles radius) is predominately inactive agricultural operations, with exception of the residential cluster to the north. The property is an inactive tree farm currently being utilized for cattle grazing. The historical site topography of undulating beds and rows/furrows remains mostly unaltered. Linear rows of commercial trees associated with its historical use also remain in many areas interspersed with trees that have recruited naturally. Page 86 of 456 Club at Indrio Creek, March 2026 Page 4 of 24 The sites natural features include two (2) isolated wetlands, classified as St. Lucie County Category III Wetlands. Additionally, one (1) of these onsite wetlands is less than 0.5 acres in size and therefore is not County jurisdictional. Remaining areas on site consist of abandoned tree nursery lands and ditches classified as other surface waters (OSW’s). Wetlands as well as other surface waters have been verified via the formal process (Application Number 260106-60453). See Appendix B of the enclosed Environmental Assessment for the wetland boundary survey reflecting the approved wetland lines and other surface waters. The Club at Indrio Creek project is for a Planned Town or Village (PTV) with the development of ~408 units (single-family and multi-family) as a Village. Additional features of this project include a clubhouse/amenity center, outdoor civic park spaces, a flow way spanning from the North end of the site to the South, as well as greenways for pedestrian connectivity. As the subject property is over 10 acres in size and contains wetlands an Environmental Impact Report (EIR) is required as part of the County approval process. See site plan submitted under separate cover. Based on section 11.02.09(A) (5) of the St. Lucie County Land Development Code (LDC), the environmental impact report shall completely depict the following: 1. Vegetation and Substrate Survey a) Extent and acreage of any areas in which vegetation typical of the primary dune extends landward of the Coastal Construction Control Line (CCCL). The property is not located along the coast or near a waterway and therefore has no dune areas or CCCL line. b) Extent and acreage of all marsh and mangrove forest areas, including substrate conditions: There are no marsh or mangrove forests on the subject property. There are two (2) jurisdictional wetlands and other surface waters (ditches). See response to question 1.d). Page 87 of 456 Club at Indrio Creek, March 2026 Page 5 of 24 c) Extent and acreage of all upland hammock forests; and, The subject property is an inactive palm tree farm now being utilized as cattle grazing lands. No native upland habitat is located within the limits of the subject property. Onsite uplands are best described as regeneration areas where post cessation of farming activities, vegetation was allowed to recruit naturally with minimal alterations such as removal of portions of the commercial tree growing areas and mowing to maintain lands for grazing. Row and furrow topography remains apparent with linear rows of commercial trees such as date palms and cabbage palms, intermixed with dense clusters of Brazilian pepper and oak trees. The understory consists of non-descript grasses and exotic cogon grass. Existing Upland Habitat FLUCCS/CLC Classification Observed is as Follows: 2241 FLUCCS, 183224 CLC: Abandoned/Fallow Tree Nursery (±119.147 acres) Representative Vegetation: Phoenix date palm trees (Phoenix dactylifera) – non-native Cabbage palm trees (Sabal palmetto) – native Brazilian pepper (Schinus terebinthifolia) – non-native invasive exotic Oaks (Quercus spp.) – native Cogon grass (Imperata cylindrica) – non-native invasive exotic Non-Descript grasses – mixture of native and non-native species As the Club at Indrio Creek site contains no native upland habitat, no native upland preserve is proposed. Please see Appendix A, Figure 7 of the enclosed Environmental Assessment for FLUCCS/Habitat Mapping d) Extent and acreage of all wetlands. Two (2) isolated jurisdictional wetlands were delineated on the subject property by Aquatic Research FL and verified by SFWMD via the formal process (Application Number 260106-60453). Both onsite wetlands are low quality systems. Page 88 of 456 Club at Indrio Creek, March 2026 Page 6 of 24 Wetland demarcated as 1 is best described as an exotic vegetation dominated wetland. Wetland 2 is a freshwater marsh. Per the St. Lucie County (SLC) Comprehensive Plan, both Wetlands 1 and 2 would be considered Category III Wetlands. As the subject property is located in a rural area that is predominantly agricultural use with a fringe of residential development, the overall location and landscape support would be moderate. The current and historical agricultural use of the subject property has resulted in impacts to the wetlands’ hydrology and community structure via factors such as degradation of water quality, topographic alterations from use in row crops and lack of management. Additionally, Wetland 1 appears to have been artificially hydrated via an artesian well which has now ceased running, resulting in further hydrological alterations. These factors have resulted in less than optimal hydrology and community structure. Wildlife support has been negatively affected due to onsite conditions that include poor management and physical impediments but would maintain general “rural area” connectivity. Impedances to wildlife access would specifically be from factors such as heavy density of exotic vegetation onsite resulting in a closed canopy with limited access both on the ground and aerially for birds. However, offsite wildlife corridors remain available due to the general rural nature of lands within 2 miles of the subject property with some impedances to ground access because of perimeter ditching, fencing and roadways. The overall community structure of the onsite wetlands is also less than optimal. Species present in Wetland 1 consists predominantly of exotic wetland vegetation such as torpedo grass, para grass and Brazilian pepper intermixed with species such as cat tails and primrose willow of which are associated with poor water quality. Wetland 2 is under 0.5 acres in size and would be considered non county jurisdictional. Furthermore, at the state level no mitigation would be required nor demonstration of avoidance and minimization of impacts. Page 89 of 456 Club at Indrio Creek, March 2026 Page 7 of 24 Wetland Descriptions & Existing Wetland Habitat FLUCCS/CLC Classifications: Wetland No. 1 (±1.88 ac) – Category III, Isolated Wetland 1 is located in the southwestern portion of the subject property, specifically on Parcel 3. This wetland system is of poor quality and appears to have partially been formed as a result of two (2) flowing, high velocity, artesian wells. During the January 2025 assessment both wells were observed to be open and actively discharging a high volume of water. One (1) well was noted at the far north end of Wetland 1, acting as a headwater for this system, consistently discharging a large volume of water noted to be flowing south. A second well was observed near the center of the Wetland also adding large quantities of water into the system. Both wells were capped with no further discharge as of the August 2025, site visit. During the August visit water was observed to have receded south with dry areas in the vicinity of the original “headwater” well. Soils have continued to transition, becoming more sandy and losing their dark mucky surface in concert with loss of wetland plants such as cattails. As of February 2026, the wetland has further receded and appears to have hydrologically stabilized, with standing water and wetland vegetation remaining in the southern end, resulting in the final configuration as approved by the SFWMD and shown on the project site plan. Community structure of Wetland 1 is almost solely (±90%) exotic invasive species as well as species commonly associated with poor water quality such as torpedo grass, para grass, water lettuce, cattails, and Brazilian pepper. Minimal recruitment of native vegetation was noted; water quality is poor receiving agricultural runoff with plants indicative of a high nutrient environment and light penetration is limited. Topography within this system is also severely altered with notable areas of degraded farm furrows, which have further contributed to its ability to hold water artificially. Utilizing UMAM to score the condition of this wetland, function is estimated to be a 0.4. 619 FLUCCS/74 CLC: Exotic Wetland Hardwoods ±1.88 ac Page 90 of 456 Club at Indrio Creek, March 2026 Page 8 of 24 Representative Vegetation: Cuban club-rush (Cyperus blepharoleptos) – non-native Hygrophila (Hygrophila polysperma) – non-native Para grass (Urochloa mutica) – non-native Torpedo grass (Panicum repens) – non-native Water Spinach (Ipomoea aquatica) – non-native Pickerelweed (Pontederia cordata) – native Brazilian pepper (Schinus terebinthifolia) – non-native Phoenix date palm trees (Phoenix dactylifera) – non-native Cabbage palm trees (Sabal palmetto) – native Wetland No. 2 (±0.17 acres) – Category III, Isolated, Non County Jurisdictional Wetland 2 is located on Parcel 5. This is a freshwater marsh system that appears to have formed as result of seasonal conditions and high precipitation events causing overflow of the adjacent farm ditch. This system is of low to moderate ecological condition. Community structure consists of both native and exotic species. Hydrology is sufficient to support wetland function. Water quality is poor, receiving untreated agricultural drainage. 641 FLUCCS/ 2121 CLC: Freshwater Marsh Representative Vegetation: Duck potato (Sagittaria lancifolia) – native Pickerelweed (Pontederia cordata) – native Cuban club-rush (Cyperus blepharoleptos) – non-native Torpedo grass (Panicum repens) – non-native Other Surface Waters The historic undulating topography resulting from the creation of beds and furrows on the site is still present. Additionally, the agricultural irrigation and drainage ditches as well as artesian wells are still present but capped as of August 2025, except for one (1) well flowing at low velocity for cattle hydration. Page 91 of 456 Club at Indrio Creek, March 2026 Page 9 of 24 510 FLUCCS, 183224 CLC: Artificial Waterway/Farm Ditch (±5.832 acres) Please see Appendix A, Figure 7 of the enclosed Environmental Assessment for FLUCCS/Habitat Mapping 2. Statement of jurisdictional control over the environmental area The subject property contains two (2) low quality isolated state jurisdictional wetlands. Per the St. Lucie County Comprehensive Plan, both Wetlands 1 and 2 are less than 5 acres in size and would be considered Category III Wetlands requiring a 25-foot buffer. Based on the low ecological condition of Wetland 1, impacts should be feasible at both the County and the State levels. Mitigation would be required for impacts and can be provided via the purchase of wetland credits from a mitigation bank with a service area that covers the subject property. Wetland 2 (±0.17 acres), being under 0.5 acres in size, would be considered non county jurisdictional in accordance with the Comprehensive Plan and LDC. Wetlands under 0.5 acres in size, per the SFWMD Basis of Review, further require no mitigation at the state level nor demonstration of avoidance and minimization of impacts. Any proposed wetland impacts will require obtaining a State Environmental Resource Permit (ERP) and St. Lucie County Wetland Waiver, process of which includes, demonstration of avoidance and minimization of impacts and providing compensatory mitigation for impacts to all non isolated wetlands and isolated wetlands over 0.5 acres in size. As also discussed in Question 1b above, the subject property contains OSW’s that include farm ditches. These water bodies do not exhibit any wetland function. However, portions may be considered suitable for wood stork foraging and a foraging assessment may be required if ditches are to be impacted as part of site development. No native uplands are present on the subject property; therefore no native upland preserve is proposed. Page 92 of 456 Club at Indrio Creek, March 2026 Page 10 of 24 St. Lucie County will maintain jurisdiction over on-site trees qualifying for protection under the Land Development Code (LDC). All cabbage palms over 10’ clear trunk (CT) and native hardwoods/softwoods meeting the protection standard will be mitigated either through preservation, over sizing of landscape trees, payment into the county tree fund, replanting, or a combination thereof. 3. Statement on when the jurisdictional boundaries were delineated and who delineated the boundaries. Two (2) isolated jurisdictional wetlands were delineated on the subject property by Aquatic Research FL and verified by SFWMD on February 12, 2026, via the formal process (Application Number 260106-60453). Survey has been completed, demonstrating the approved limits of these features and can be found in Attachment 2. All documents have been provided to SFWMD for review and issuance of the approved formal determination letter is forthcoming. 4. Indicate the required first floor elevation, and whether all floor elevations will be above this level. See site plan as prepared by others submitted under separate cover. 5. Identification of any area that has experienced overwash of the primary dune. No dune is present. Property is located inland. 6. Identification of any area subject to breach during storm conditions. Not applicable. 7. Assessment of the impacts upon onsite vegetation and wildlife. Development of the site will have impacts to protected trees. Trees shall be mitigated for via upsizing of required landscape trees, payment into the County tree fund, relocation, planting or a combination thereof. Page 93 of 456 Club at Indrio Creek, March 2026 Page 11 of 24 A listed flora and fauna survey was conducted by Aquatic Research FL on February 12, 2026, with additional assessments also conducted on August 1, 2025, and in January of 2025. As part of the listed flora and fauna survey an FFWCC compliant inspection was also made for gopher tortoise burrows as well as burrowing owl burrows. See Appendix A Figures 4, 5, & 6 of the Enclosed Environmental Assessment for Transect Maps No listed flora or fauna dens, nests, burrows or roosting areas were observed on the subject property. Additionally, no gopher tortoise or burrowing owl burrows were observed on the subject property. However, the subject property is within the Core Foraging Area for the wood stork as well as in the USFWS Consultation Area for the crested caracara and special considerations will be applied as described below: • The subject property is within the Core Foraging Area (CFA) for the wood stork. However, as of March 9, 2026, the wood stork has been federally delisted. If the delisting plan involves keeping the protection mechanisms established for foraging, portions of onsite ditches are potentially suitable for wood stork forage and mitigation could be required if filling is proposed. • The subject property is also within the USFWS Consultation Area for the Audubon’s crested caracara, a Federally protected bird. However, suitable nesting habitat is very minimal with larger mature palms being located within thick clusters of shrubs and exotic Brazilian pepper trees. Furthermore, the overall vegetative density on the subject property is high, making onsite habitats very marginal and highly unlikely to support nesting. Regardless, during this and previous assessments conducted by Aquatic Research FL, all potential nesting trees were surveyed for evidence of current or historical nesting. Utilizing the effect determination key for the caracara, implementation of protection measures that include either no clearing during nesting season or a preconstruction survey prior to clearing should result in a may affect not likely to effect status as required for project approval. A technical consultation with USFWS has been initiated. Page 94 of 456 Club at Indrio Creek, March 2026 Page 12 of 24 Please see the enclosed environmental assessment with listed species survey conducted by Aquatic Research FL for detailed survey methodology and listed flora and fauna species endemic to this region. 8. Assessment of the impacts upon onsite and off-site natural resources. Proposed onsite alterations include impacts to non-native upland habitat (abandoned/fallow tree nursery) and two (2) isolated wetlands (Wetlands 1 and 2). Wetland 1 is an exotic dominated system, 1.88 acres in size. Wetland 2 is 0.17 acres and therefore will not require state mitigation for impacts. Furthermore, as outlined in Section 6.02.03B of the St. Lucie County Land Development Code, isolated wetlands under 0.5 acres in size are not County jurisdictional. Therefore, in accordance with the SFWMD Basis of Review and County LDC mitigation will be required for impacts to Wetland 1 only. Mitigation for Wetland 1 will be done via the purchase of mitigation credits, from Bluefield Ranch Mitigation Bank, which has a service area covering the subject property. Utilizing the Uniform Mitigation Assessment Methodology (UMAM) for the assessment of wetland impacts, a purchase of 0.75 credits is estimated. As the state Environmental Resource Permit (ERP) process has not yet been initiated, final/approved impact figures are not yet available. Final calculations of impacts shall be provided to the County as part of the ERP process. With regards to tree mitigation all cabbage palms over 10’ clear trunk (CT) and native hardwoods/softwoods meeting the county protection criteria will be mitigated either through preservation, over sizing of landscape trees, payment into the county tree fund, replanting, or a combination thereof. A full mitigation plan shall be provided by the project planner. No impacts to offsite resources are proposed. The stormwater system also has been designed in accordance with state and federal required nutrient and discharge standards as applicable. Page 95 of 456 Club at Indrio Creek, March 2026 Page 13 of 24 9. Detailed description of the planned approach to minimize impacts. The Club at Indrio Creek site plan has been designed to incorporate the site’s most notable ecological benefits to the greatest possible extents while maintaining reasonable useability of the site. To achieve this goal, during the initial planning the ecology of the site was extensively analyzed with a focus on avoidance and minimization of impacts to features such as wetlands as well as maintaining and enhancing existing ecological benefits. To begin this process ecological assessments such as analysis of habitat types and quality, the location and jurisdictional boundaries of onsite wetlands as well as survey for listed flora and fauna were initiated. Results of these findings indicated that the subject property contained two (2) Category III Wetlands, other surface waters which included farm ditches, and non native uplands associated with the site’s current as well as historical use in agricultural. Listed species surveys indicated no listed flora or fauna nesting, denning or roosting on the subject property. The subject property is within the USFWS consultation area for the crested caracara as well as potentially containing ditches suitable for wood stork foraging. With regards to the wood stork, as this bird has been federally delisted, if protection measures currently in place remain, a foraging assessment will be conducted with forage losses to be offset as required during the state permitting process. Furthermore, as a large continuous flow way is proposed to be created with a planted littoral shelf, any proposed loss of forage from the existing agricultural ditches should be offset and ultimately improved long term. With regards to the caracara, as overall vegetative density on the subject property is high, onsite habitat areas are very marginal and very unlikely to support nesting. Regardless, implementation of protection measures that include either no clearing during nesting season or a preconstruction survey prior to clearing are proposed and a technical consultation with USFWS has been initiated. The subject property in its current condition provides minimal ecological value with its greatest benefit likely being its function as a wildlife corridor. As noted during the EA conducted by Aquatic Research FL, the onsite wetlands are isolated systems that are not unique to the area and do not currently contain the Page 96 of 456 Club at Indrio Creek, March 2026 Page 14 of 24 proper hydrology nor community structure necessary for the support of listed species or wading birds. Overall ecological value would be considered as such that the purchase of credits from a mitigation bank would provide greater ecological value than the wetlands being affected. This was determined during the habitat assessment and subsequent UMAM scoring of which included reviewing ecological factors such as overall conditions, hydrologic connections, uniqueness, location and fish and wildlife usage. Description of these ecological conditions are as follows: Condition: All onsite wetlands are located interior to a fallow tree farm/agricultural field, with poor plant diversity, a high density of exotic and transitional upland vegetation as well as poor wildlife access and usage. Wetland 1 has experienced significant hydrological impacts due to artificial hydration from artesian wells. Wildlife utilization within both wetland systems appears to be minimal with no significant indications of wildlife utilization observed. Additionally, it would appear the available wildlife corridors are active agricultural lands that are partially fragmented due to roads, fencing and ditches. Hydrology and community structure are not sufficient to support listed wading bird nesting. Within Wetland 1, vegetation is predominantly exotic species as well as those associated with poor water quality, such as cattails and primrose willow. Little natural recruitment is apparent with the intrusion of upland species scattered throughout this wetland. Within Wetland 2 plant species and diversity are improved however, this is a small system (0.17 acres), offering minimal support due to size, density of exotic vegetation in surrounding uplands and receipt of untreated agricultural runoff historically. Topological features within both Wetlands 1 and 2 are lacking and structural habitat is not present. See Attachment 3 for UMAM scores. Hydrologic connection – Both onsite wetlands are isolated systems with no offsite or connections to other surface waters. With regards to Wetland 1, in 2025 three (3) or more wells were noted to be running on the site, each discharging water at a high velocity resulting in the expansion of Wetland 1. As of the February 2026 assessment, the majority of the artesian wells have been capped and hydrologic conditions stabilized, resulting in wetlands limits as demonstrated in the enclosed wetland boundary survey. Page 97 of 456 Club at Indrio Creek, March 2026 Page 15 of 24 Neither onsite wetland has sufficient hydrology to support wading bird nesting and provide no tangible benefit to off-site water resources through detrital export, base flow maintenance, water quality enhancement or the provision of nursery habitat. Uniqueness – Both wetlands are agricultural based systems created from various related factors such as lack of maintenance of drainage features, erosion of rows and furrows, and use of artesian wells. Vegetation within Wetland 1 consists mainly of exotic species as well as those commonly associated with poor water quality. All wetlands are buffered or surrounded by nonnative disturbed uplands. Onsite wetlands are not unique to the region. Location – Wetlands are within a rural area that is predominantly agricultural with a fringe of residential development and roadway to the north. The current and historical agricultural use of the subject property has resulted in impacts to the wetlands’ hydrology and community structure via factors such as degradation of water quality, topographic alterations from use in row crops and lack of management. Wildlife support has been negatively affected due to onsite conditions that include poor management and physical impediments but would maintain general “rural area” connectivity. Impedances to wildlife access would specifically be from factors such as Indrio Rd to the north, perimeter ditching, fencing and a heavy density of exotic vegetation onsite resulting in a closed canopy with limited access both on the ground and aerially for birds. Offsite wildlife corridors are partially disturbed due to the aforementioned factors but also remain available due to the general rural nature of lands within 2 miles of the subject property. Conditions are less than optimal and general location should be considered moderate to slightly below with additional loss based on plant community composition in the proximity of the assessment area. Fish and wildlife utilization – Wildlife access has been fragmented due to surrounding ditches and roadways and most significantly heavy coverage of exotic vegetative species. Wetlands are shallow with insufficient hydrology for wading birds and are not appropriate for the support of listed species. Expected use is reptiles and small mammals such as rodents. Page 98 of 456 Club at Indrio Creek, March 2026 Page 16 of 24 While the onsite wetlands are agricultural based systems of low quality as described above regardless, during the planning process avoidance and minimization was considered and each wetland reviewed with regards to impacts. Wetland No. 1 (SW corner – 1.88 acres) - 1.88 acres of impacts proposed Impacts to this wetland system were reviewed considering both ecological conditions as discussed above as well as design consideration within the constraints of the TVC and general SLC site plan requirements. Flow way - Per the TVC standards a flow way or continuous water management system is required. A consolidated flow way located around the perimeter of a site is the preferred configuration from both a layout and engineering standpoint. In the case of the Indrio Creek site, the flow could be provided along the east or west side. Either option would result in resource impacts as the majority of protected trees fall within the eastern side as well as the 0.17 acre wetland. Again as previously discussed, impacts to Wetland 1 would not be considered to be of high ecological significance and providing offsite mitigation would be of greater value than attempts at onsite preservation post site development. Furthermore, as the proposed flow way is to be created with a graded and planted littoral shelf as well as an upland transitional zone, the resulting large scale interconnected flow way will provide a far greater ecological benefit than preservation of a low quality agricultural wetland. The proposed flow way has the potential to provide a large continuous area of forage for various listed species of wading birds including wood storks as well as large to medium size mammals, reptiles and amphibians. . Transect Zones - Per TVC code, each part of the development requires a “transect zone” of certain percentages. The site plan layout as shown in which Wetland 1 is impacted by the flow way provides a “rural transect zone.” along the site perimeter as required that can encompass lake or open space. Buffering – Buffering of adjacent property’s, especially if usages are different, is a county requirement and highly preferred by residents to be of the greatest width and density possible. As the site plan demonstrates, the flow way in its proposed location offers substantial buffering along that SW portion. Page 99 of 456 Club at Indrio Creek, March 2026 Page 17 of 24 Buffering is also being shown to the NE with the creation of a greenway. Swapping these areas to avoid impacts to Wetland 1 was considered during design but would still result in resource impacts as trees now being offered for preservation would then need to be impacted. Preservation of the wetland in its current condition would not offer a significant ecological lift. E/W Road Alignment - The site is proposed to be bisected by a required County E/W Road (east/west). The project is designed around this road and is shown on the site plan in the County’s requested location. Based on this, additional considerations of layout had to be made so that this road could access the necessary or “useable “portions of the site. The road in this location, the requirement for a continuous flow way with a perimeter locational preference as well as green way requirements, again result in impacts to Wetland 1. Density & Zoning – The project requires a minimum density and unit count which is affected by placement of lots, open space, flow way and generally all site components. The current site layout satisfies the minimum density. To do so, components such as flow ways and green spaces again needed to be placed along the perimeter, impacting Wetland 1. Wetland No. 2 (NE – 0.17 acres) – Non county jurisdictional 0.17 acres of impacts proposed. While Wetland 2 per County LDC and Comprehensive Plan is considered non jurisdictional and further requires no state mitigation nor demonstration of avoidance and minimization, consideration was still made with regard to impacts. Similar issues as described with Wetland 1 further applied to this smaller system. Items such as flow ways and greenspaces are required to be incorporated as well as minimum densities must be adhered to, resulting in a tight site plan configuration. Allowances have been made for tree preservation and in the case of Wetland 2, tree preservation was given increased priority by placing park lands in the vicinity of the highest density of preservation trees on the subject property. Additionally, the project is required to incorporate 3 civic buildings which again result in further loss of space. To potentially gain minimally green space back, the project does propose the use of outdoor civic parks in lieu of structures, which are to be within the area of Wetland 2. Page 100 of 456 Club at Indrio Creek, March 2026 Page 18 of 24 Overall, the site plan as presented for the Club at Indrio Creek demonstrates the incorporation of avoidance and minimization of impacts. These factors were considered in great detail during all phases of project development and design. The resulting site plan provides a sound design with minimal ecological impacts and onsite and offsite enhancements via the creation of a large continuous flow way with the potential to exceed proposed ecological losses from impacting a low quality wetland. 10. Detailed description of the proposed alterations or disturbances being proposed. The Club at Indrio Creek is for a Planned Town or Village (PTV) with the development of 408 units (single-family and multi-family) as a Village. Additional features of this project include a clubhouse/amenity center, outdoor civic park spaces, a flow way spanning from the North end of the site to the South, as well as greenways for pedestrian connectivity. Development of the Club at Indrio Creek will result in impacts to non-native uplands, as well as two (2) isolated wetlands. Mitigation shall be provided in accordance with the SFWMD Basis of Review and include the purchase of 0.75 credits from Bluefield Ranch Mitigation Bank for impacts to Wetland 1. Wetland 2 is isolated and under 0.5 acres in size and will require no mitigation for impacts. Therefore, project based impacts include non native upland alterations as well as impacts to low quality isolated wetlands. Removal of trees qualifying for protection under County standards shall be addressed as demonstrated in the landscape plans. 11. Detailed description of the proposed mitigation plan to offset impacts. The site proposes no impacts to native uplands, or areas identified as unique to the region or supporting listed flora or fauna nesting, denning or roosting. Impacts are proposed to Wetlands 1 and 2 in their entirety as part of site development. Wetland 2 is under 0.5 acres in size and therefore will not require state mitigation for impacts. Page 101 of 456 Club at Indrio Creek, March 2026 Page 19 of 24 Furthermore, as outlined in Section 6.02.03B of the St. Lucie County Land Development Code, wetlands under 0.5 acres in size are not County jurisdictional. Therefore, in accordance with the SFWMD Basis of Review and County LDC, mitigation will solely be required for impacts to Wetland 1. To determine the amount of required mitigation for impacts to Wetland 1 the state approved UMAM scoring system was utilized. This resulted in a preliminary estimate of a need for 0.75 credits to offset impacts. Credits are proposed to be purchased from Bluefield Mitigation Ranch, having a service area that covers the subject property. Purchase of wetland mitigation credits will be done in concert with the state Environmental Resource Permit (ERP). 12. Plant and animal surveys for onsite federal and state protected species. During the field assessment pedestrian transects were made throughout the subject property to observe for the presence of any state or federal listed fauna species as well as wildlife in general. This included observations of individual animals as well as dens, burrows, roosting areas, or nests. Multiple linear transects were completed across all habitat areas. Distances between transects varied in the field depending on terrain, with larger distances between open areas with low lying vegetation, smaller in areas with dense vegetation or suspected listed species occupation. See Appendix A, Figures 4, 5, and 6 of the Enclosed Environmental Assessment for Survey Transect Maps. One hundred and twenty-two (122) transects were established to perform the habitat assessment and listed flora and fauna species survey. The survey was conducted within ±49 acres (±39%) of the ±127.029-acre property. Total Acreage of Property ±127.029 ac Total Acreage of Property Surveyed ±49.0 ac Total Percent of Property Surveyed 38% The wildlife population was documented in the field by visual observation of individual animals as well as, tracks, scat, dens, foraging and nesting. A FFWCC compliant minimum 15% gopher tortoise and burrowing owl survey was also conducted. No owl or gopher tortoise burrows, or indication of usage was observed during the survey. Page 102 of 456 Club at Indrio Creek, March 2026 Page 20 of 24 No other listed species dens, nests, burrows, or roosting areas were observed. No listed flora was observed. See tables below for the list of potential protected species and species observations (listed and non-listed). Species Common Name Federal Status State Listing Observation(s) Mammal Presence Felis concolor coryi Florida panther puma E E None Observed Peromyscus polionotus niveiiventris Southeastern beach mouse T T None Observed Bird Presence Athene cunicularia floridana Florida burrowing owl N T None Observed Laterallus jamaicensis plancus audobonii Eastern black rail T T None Observed Polyborus plancus audubonii crested caracara T T None Observed Rostrhamus sociabillis plumbeus Everglades snail kite T T None Observed Reptile Presence Alligator mississippiensis American alligator T T None Observed Drymarchon corais couperi Eastern indigo snake T T None Observed Gopherus polyphemus gopher tortoise C T None Observed Pituophis melanoleucus pine snake C T None Observed Insect Presence Anaea troglodyta oridalis Florida leafwing butterfly E E None Observed Cyclargus thomasi bethunebakeri Miami blue butterfly E E None Observed Danus plexippus monarch butterfly E FE None Observed Migratory Bird Breeds Presence Aimophila aestivalis Bachman's sparrow BCC May 1 to Sep 30 None Observed Ardea herodias occidentalis great blue heron BCC Jan 1 to Dec 31 None Observed Arenaria interpres morinella ruddy turnstone BCC Breeds Elsewhere None Observed Calidris melanotos pectoral sandpiper BCC Breeds Elsewhere None Observed Page 103 of 456 Club at Indrio Creek, March 2026 Page 21 of 24 Calidris pusilla semipalmated sandpiper BCC Breeds Elsewhere None Observed Chaetura pelagica chimney swift BCC Mar 15 to Aug 26 None Observed Charadrius wilsonia Willson's plover BCC Apr 1 Aug 20 None Observed Dendroica discolor prairie warbler BCC May 1 to Jul 31 None Observed Egretta rufescens reddish egret BCC Mar 1 to Sep 15 None Observed Falco sparverius paulus American kestrel BCC Apr 1 to Aug 31 None Observed Fregata magnificens magnificent frigatebird BCC Oct 1 to Apr 30 None Observed Limnodromus griseus short-billed dowitcher BCC Breeds Elsewhere None Observed Passerina ciris painted bunting BCC Apr 25 to Aug 15 None Observed Sternula antillarum least tern BCC Apr 25 to Sep 5 None Observed Tringa avipes lesser yellowlegs BCC Breeds Elsewhere None Observed Florida Natural Inventory Areas (FNAI) Biodiversity Index U.S. Fish and Wildlife Service (USFWS) Endangered Species List Plant Species Common Name *Federal Status State Listing Observation(s) Cereus eriophorus var. fragrans fragrant prickly-apple E E None Observed Coelorachis tuberculosa piedmont jointgrass N T None Observed Conradina grandiflora large-flowered rosemary N T None Observed Glandularia maritima coastal vervain N E None Observed Lechea cernua nodding pinweed N T None Observed Linum carteri var. smallii Small's flax N T None Observed Nemastylis floridana celestial lily N E None Observed Page 104 of 456 Club at Indrio Creek, March 2026 Page 22 of 24 Polygala smallii tiny polygala E E None Observed Zephyranthes simpsonii redmargin zephyrlily N T None Observed Non-Listed Species Observation(s) Type Species Common Name Reptiles N/A N/A Mammals Rabbit scat N/A Aves Bubulcus ibis cattle egret Columbina passerina ground doves Charadrius vociferus killdear The subject property lies within the USFWS Consultation Area for the crested caracara and well as within the core foraging area for the wood stork. The crested caracara occupies open pasture type lands with mature solitary palms. The subject property does contain pasture lands and maintains areas that could be suitable for foraging. The site does also contain mature cabbage palms but planted in linear rows or in clustered configurations along ditches. Additionally, these areas of trees and palms are further interspersed within dense patches of shrubs and exotic Brazilian pepper trees, being representative of the overall vegetative density on the subject property; high and making onsite habitats very marginal and unlikely to support nesting. Regardless, during this and all previous assessments conducted by Aquatic Research FL on the subject property, observations were made for current or historical nesting within any palms/trees being even marginally suitable for nesting. No evidence of current or historical nesting was noted (stomped fronds, pellets, bones or other signs of predation at base of trees). Utilizing the USFWS effect determination key for the crested caracara, site characteristics in concert with the below proposed construction conditions result in a may affect not likely to effect determination as required for project construction. Proposed conditions: • No construction during nesting season or • If construction is to occur during nesting season the completion of a pre construction survey to ensure no new/unexpected nesting has occurred nor Page 105 of 456 Club at Indrio Creek, March 2026 Page 23 of 24 birds observed on the property displaying nest building behaviors that would indicate the property to be within the territory of a nesting pair. A technical consultation has been initiated was USFWS in order to verify that development of the subject property would result in a may affect not like to effect determination based on the aforementioned site and construction conditions. With regards to the wood stork, during the assessment it was determined that portions of the onsite ditches could be considered suitable for wood stork foraging. However as of March 9, 2026, the wood stork was federally delisted with protection mechanisms to be transferred to the states and agencies such as Florida Fish and Wildlife Conservation Commission (FFWCC). The wood stork will remain federally protected under the Migratory Bird Act and Clean Water Act as well as be subject to 10 years of delisting monitoring efforts. During this transitional period protection mechanisms will likely remain and if that does apply, site development resulting in the filling of onsite ditches or smaller farm furrows could still require a wood stork forage and biomass analysis. Therefore, as discussed in Section 3.1 of this report, if protection mechanisms remain for this species post delisting, alteration to the property that encompasses filling of ditches or waterbodies considered suitable for wood stork forage could require assessment for loss of wood stork forage and subsequent mitigation for calculated loss. If the wood stork assessment determines forage area is to be lost in association with development of the Club at Indrio Creek Project, mitigation for those losses can be done onsite via preservation or creation of other forage areas or offsite via the purchase of credits from a wetland mitigation bank offering wood stork credits. The creation of an onsite lake with a vegetated littoral shelf could also be used to partially or fully offset onsite forage impacts. In the case of the Club at Indrio Creek Project, the proposed flow way likely would be suitable for mitigation and further providing highly improved habitat. 13. Surface water management plan and written assessment including a description of techniques to be used to prevent both the potential degradation of surface water resources and an increase in flood hazard damage. To be submitted under separate cover as part of engineering documents as applicable. Page 106 of 456 Club at Indrio Creek, March 2026 Page 24 of 24 14. A sea turtle protection plan. Not applicable. 15. A shoreline stabilization plan. Not applicable. 16. A gopher tortoise protection plan. On February 12, 2026, as well as in August and January of 2025, Aquatic Research FL conducted a 15% minimum habitat survey for gopher tortoise burrows. No potentially occupied gopher tortoise burrows were observed. Page 107 of 456 Attachment 1 Environmental Assessment Page 108 of 456 Environmental Assessment Club at Indio Creek S of Indrio Road, W of Emerson Avenue, & E of Seminole Road, Unincorporated St. Lucie County, Florida Section 14, Township 34 S, Range 39 E Parcel Identification Number (PIN) Address 1314-323-0002-000-3 Unassigned Emerson Avenue 1314-313-0000-000-8 Unassigned Seminole Road 1314-331-0001-000-1 Unassigned Emerson Avenue 1314-342-0001-000-5 Unassigned Seminole Road 1314-341-0000-000-5 Unassigned Seminole Road 1323-211-0005-000-8 Unassigned Seminole Road Prepared For: St. Lucie County ERD SFWMD & Loxahatchee Holdings LP Inc. 501 E. Las Olas Blvd Fort Lauderdale FL 33301 Prepared By: March 2026 ENVIRONMENTAL CONSULTING WETLANDS , PROTECTED SPECIES, & PERMITTING Aquatic RESEARCH FL.com Page 109 of 456 Club at Indrio Creek Unincorporated St. Lucie County, Florida S of Indrio Rd., E of Emerson Ave. & W of Seminole Rd. March 2026 Page 2 of 26 Table of Contents 1.0 Introduction and Site Description ......................................................................................................... 3 2.0 Vegetation, Habitat Description, and Listed Flora Survey Results .................................................... 6 2.1 Upland Habitat .................................................................................................................................... 7 2.2 Wetland Habitat ................................................................................................................................... 8 2.3 Other Surface Waters: ........................................................................................................................11 3.0 Wildlife Evaluation and Listed Fauna Survey ....................................................................................11 3.1 US Fish and Wildlife Service (USFWS) Consultation Areas ............................................................12 3.2 Listed Fauna with a General Wildlife Survey Methods and Results ................................................13 3.2.1 Gopher Tortoise (Gopherus Polyphemus) ..................................................................................16 3.2.1.1 Gopher Tortoise Survey Methodology ..................................................................................17 3.2.2 Burrowing Owl (Athene cunicularia) .........................................................................................18 3.2.2.1 Burrowing Owl (Athene cunicularia) Survey Methodology and Results............................18 3.2.3 Wood Stork (Mycteria americana) ..............................................................................................19 3.3 Conservation Lands ............................................................................................................................20 4.0 Permit and Local Government Review ................................................................................................20 4.1 Permit Review .....................................................................................................................................20 4.2. Local Government Review and Wetland Impact Permitting ............................................................21 5.0 Soils .........................................................................................................................................................22 6.0 Summary ................................................................................................................................................22 7.0 Transect Data .........................................................................................................................................25 Appendix A Figure 1: Location Map Figure 2: Site Map Figure 3: Agency Reported Land Use Map Figure 4: General Wildlife Survey including Listed Flora & Fauna Transect Map Figure 5: General Wildlife Survey including Listed Flora & Fauna Transect Map Figure 6: General Wildlife Survey including Listed Flora & Fauna Transect Map Figure 7: Existing Habitat/FLUCCS-CLC Map Figure 8: Soils(s) Map Appendix B Site Photographs Appendix C Information for Planning and Consultation (IPAC) Appendix D Wetlands & OSW Boundary Survey Page 110 of 456 Club at Indrio Creek Unincorporated St. Lucie County, Florida S of Indrio Rd., E of Emerson Ave. & W of Seminole Rd. March 2026 Page 3 of 26 1.0 Introduction and Site Description In support of the proposed Club at Indrio Creek project, an environmental assessment (EA) was conducted by the qualified biologists with Aquatic Research, Monitoring, Equipment, & Deployment, LLC (Aquatic Research FL) on February 12, 2026. Site visits were also conducted on August 1, 2025, and in January of 2025. The subject property was reviewed in accordance with the St. Lucie County Land Development Code (LDC) and Comprehensive Plan with regards to environmental assessments. Therefore, this EA includes a survey for species of special concern, threatened, or endangered along with site/habitat characteristics conducive to support such species. As part of the assessment for listed species, a Florida Fish and Wildlife Conservation Commission (FFWCC) compliant 15% minimum habitat survey for gopher tortoise (Gopherus polyphemus) and burrowing owl (Athene cunicularia) burrows were also conducted. Furthermore, the site was assessed for the presence of state or federal jurisdictional wetlands, native upland habitat, environmentally significant lands, and adjacent conservation lands of significance. Listed flora and fauna surveys were conducted in accordance with the following applicable species-specific standards; Florida Fish and Wildlife Conservation Commission (FFWCC) Gopher Tortoise Permitting Guidelines, April 2008, Revised April 2023, FFWCC Owl Species Conservation Measures and Permitting Guidelines 2018, FFWCC Site Specific Wildlife Assessment and Survey Planning Tools 2022 and Florida Natural Plant Society (FNPS) Floristic Inventory and Plant Survey Guidance. The subject property, Club at Indrio Creek, is ±127.029 acres and consists of six (6) parcels. It is located south of Indrio Road/SR-614, east of Emerson Avenue, and west of Seminole Road within unincorporated St. Lucie County Florida. Please see Appendix A, Figure 1 for the Location Map. Map ID# Parcel Identification Number (PIN) Address 1 1314-323-0002-000-3 Unassigned Emerson Avenue 2 1314-313-0000-000-8 Unassigned Seminole Road 3 1314-331-0001-000-1 Unassigned Emerson Avenue 4 1314-342-0001-000-5 Unassigned Seminole Road 5 1314-341-0000-000-5 Unassigned Seminole Road 6 1323-211-0005-000-8 Unassigned Seminole Road Table 1.0. Parcel identification numbers, location, and acreage Page 111 of 456 Club at Indrio Creek Unincorporated St. Lucie County, Florida S of Indrio Rd., E of Emerson Ave. & W of Seminole Rd. March 2026 Page 4 of 26 The site is bordered to the north and south by inactive agriculture areas. Further north are single family home lots and PUD style communities. The western property boundary is adjacent to an offsite ditch and Emerson Avenue. Further west is the Fort Pierce Farms Water Control District (FPFWCD) Canal No.6 and inactive agricultural lands. To the east is FPFWCD Canal No. 5 and Seminole Road followed by inactive agriculture areas. Please see Appendix A Figure 2 for Site Map. The immediate surrounding area (±2 miles radius) is predominately inactive agricultural operations, with exception of the residential cluster to the north. A site visit was conducted most recently on February 12, 2026, with additional assessments also conducted on August 1, 2025, and in January of 2025 by Aquatic Research FL’s team of qualified biologists (Appendix B Site Photographs). Based on the findings of the assessment on site habitats consist of non-native uplands, wetlands and other surface waters. The property is an inactive tree farm currently being utilized for cattle grazing. The historical site topography of undulating beds and rows/furrows remains mostly unaltered. Linear rows of commercial trees associated with its historical use also remain in many areas interspersed with trees that have recruited naturally. No native upland habitat is located within the limits of the subject property. Two (2) isolated jurisdictional wetlands were delineated on the subject property by Aquatic Research FL and verified by SFWMD via the formal process (Application Number 260106-60453). Both onsite wetlands are low quality systems. Wetland demarcated as 1 is described as an exotic vegetation dominated wetland. Wetland 2 is a freshwater marsh. The subject property also contains other surface waters (OSW) which include multiple farm ditches associated with its historical use in agriculture. Per the St. Lucie County (SLC) Comprehensive Plan, both Wetlands 1 and 2 would be considered Category III Wetlands requiring a 25-foot buffer. Based on the less than optimal ecological condition of the onsite wetlands, as well as Wetland 2 being under 0.5 acres in size, impacts are feasible at both the County and the State levels. Per the SLC LDC, Comprehensive Plan and at the state level the SFWMD Basis of Review, isolated wetlands under 0.5 acres require no mitigation for impacts. Page 112 of 456 Club at Indrio Creek Unincorporated St. Lucie County, Florida S of Indrio Rd., E of Emerson Ave. & W of Seminole Rd. March 2026 Page 5 of 26 Any proposed wetland impacts will require obtaining a State Environmental Resource Permit (ERP) and St. Lucie County Wetland Waiver. Wetland 1 is estimated to score a 0.4 utilizing the Uniform Mitigation Assessment Method (UMAM). Per the SFWMD Basis of review, demonstration of avoidance and minimization may not be required at the state level for Wetland 1 as the proposed mitigation will likely provide greater long term ecological value than the area of wetland to be adversely affected. Mitigation for impacts to Wetland 1 can be provided via the purchase of credits from a state permitted mitigation bank. Additionally, since the subject property contains wetlands, any site development application will require the submission of a sixteen (16) part Environmental Impact Report (EIR) to the St. Lucie County Environmental Resources Department (ERD). As the subject property is over 1 acre in size, in accordance with the St. Lucie County Land Development Code (LDC) site development will also require a tree survey with mitigation for impacts to protected trees. No listed flora species were observed within the limits of the subject property. No listed fauna dens, nests or roosting areas were observed within the limits of the subject property. A Florida Fish and Wildlife Conservation Commission (FFWCC) compliant 15% habitat survey for gopher tortoise (Gopherus polyphemus) and burrowing owl (Athene cunicularia) burrows was also conducted. No gopher tortoise or owl burrows or indications of usage by these species were observed on the subject property. Furthermore, wildlife transects indicated no other listed species dens, nests, burrows, or roosting areas. The subject property is within the Core Foraging Area (CFA) for the wood stork. However, as of March 9, 2026, the wood stork has been federally delisted. If the delisting plan involves keeping the protection mechanisms established for foraging, portions of onsite ditches are potentially suitable for wood stork forage and mitigation could be required if filling is proposed. Page 113 of 456 Club at Indrio Creek Unincorporated St. Lucie County, Florida S of Indrio Rd., E of Emerson Ave. & W of Seminole Rd. March 2026 Page 6 of 26 The subject property is also within the USFWS Consultation Area for the Audubon’s crested caracara, a Federally protected bird. However, suitable nesting habitat is very minimal due to clustering of palms and high vegetative density on the subject property. Regardless, during this and previous assessments conducted by Aquatic Research FL, all potential nesting trees were surveyed for evidence of current or historical nesting. Utilizing the effect determination key for the caracara, implementation of protection measures that include either no clearing during nesting season or a preconstruction survey prior to clearing should result in a may affect not likely to effect status as required for project approval. A technical consultation with USFWS has been initiated. Two (2) active Consumptive Use Permit from South Florida Water Management District (SFWMD) 56-00936-W & 56-00723 for agricultural irrigation were found for the subject property. 2.0 Vegetation, Habitat Description, and Listed Flora Survey Results As part of the assessment conducted on the subject property, vegetation and habitat types were reviewed. This was accomplished utilizing a multi-faceted approach, first reviewing recent and historic aerials, previous reports conducted and then comparing visible aerial and topographic signatures to available agency recorded data such as the Florida Land Use Cover Classification System (FLUCCS) and Cooperative Land Use Cover (CLC) assigned classifications. This dataset (2012-2022) is a compilation of the Land Use/Land Cover datasets created by the 5 Water Management Districts in Florida based on imagery. See Appendix A, Figure 3 for Agency Reported FLUCCS codes. Furthermore, for the assessment of state and federal listed flora, databases such as Florida Natural Areas Inventory (FNAI) and the U.S. Fish and Wildlife Information for Planning and Consultation (IPAC) were consulted to obtain information regarding listed plants with the potential to occur on the subject property (Appendix C). After a comprehensive review of the above-mentioned data and aerials, transects were established based on expected variations in habitats. The location and size of habitat types as indicated in this report are based on the combination of desktop review and field truthing. One hundred and twenty-two (122) transects were established to perform the habitat assessment and listed flora species survey (Appendix A, Figures 4, 5, and 6). The survey was conducted within ±49 acres (±39%) of the ±127.029-acre property. Page 114 of 456 Club at Indrio Creek Unincorporated St. Lucie County, Florida S of Indrio Rd., E of Emerson Ave. & W of Seminole Rd. March 2026 Page 7 of 26 Total Acreage of Property ±127.029ac Total Acreage of Property Surveyed ±49.0ac Total Percent of Property Surveyed 39% Table 2.0.A: Approximate habitat acreage and survey acreage. No listed flora species were observed on the subject property at the time of survey. See table below for listed flora species endemic to this region of Florida. Florida Natural Inventory Areas (FNAI) Biodiversity Index U.S. Fish and Wildlife Service (USFWS) Endangered Species List Plant Species Common Name *Federal Status State Listing Observation(s) Cereus eriophorus var. fragrans fragrant prickly-apple E E None Observed Coelorachis tuberculosa piedmont jointgrass N T None Observed Conradina grandiflora large-flowered rosemary N T None Observed Glandularia maritima coastal vervain N E None Observed Lechea cernua nodding pinweed N T None Observed Linum carteri var. smallii Small's flax N T None Observed Nemastylis floridana celestial lily N E None Observed Polygala smallii tiny polygala E E None Observed Zephyranthes simpsonii redmargin zephyrlily N T None Observed Table 2.0.B: Listed flora species endemic to this region based on IPAC and FNAI. 2.1 Upland Habitat The subject property is an inactive palm tree farm now being utilized as cattle grazing lands. No native upland habitat is located within the limits of the subject property. Onsite uplands are best described as regeneration areas where post cessation of farming activities vegetation was allowed to recruit naturally with minimal alterations such as removal of portions of the commercial tree growing areas and mowing to maintain Page 115 of 456 Club at Indrio Creek Unincorporated St. Lucie County, Florida S of Indrio Rd., E of Emerson Ave. & W of Seminole Rd. March 2026 Page 8 of 26 spaces for grazing. Row and furrow topography remains apparent with linear rows of commercial trees such as date palms and cabbage palms, intermixed with dense clusters of Brazilian pepper and oak trees. The understory consists of non-descript grasses and exotic cogon grass. See Appendix A, Figure 7 for observed upland habitat type. Existing Upland Habitat FLUCCS/CLC Classification Observed is as Follows: 2241 FLUCCS, 183224 CLC: Abandoned/Fallow Tree Nursery (±119.147 acres) Representative Vegetation: Phoenix date palm trees (Phoenix dactylifera) – non-native Cabbage palm trees (Sabal palmetto) – native Brazilian pepper (Schinus terebinthifolia) – non-native invasive exotic Oaks (Quercus spp.) – native Cogon grass (Imperata cylindrica) – non-native invasive exotic Non-Descript grasses – mixture of native and non-native species 2.2 Wetland Habitat To classify an area as a wetland two (2) of the following three (3) criteria must be met: 1. 80 percent or more dominate coverage of wetland and/or facultative wet plants. 2. Indicators of hydrology 3. Presence of hydric soil. Two (2) state jurisdictional wetlands are located on the subject property. This includes an exotic hardwood dominated wetland and one (1) freshwater marsh. Wetland function is scored utilizing the Uniform Mitigation Assessment Method (UMAM). UMAM takes into account factors such as location and landscape support, water environment (hydrology), and wildlife support. Wetland 1 was scored as a 0.4 representing below optimal conditions. Wetland 2 is isolated and under 0.5 acres in size. It is therefore non County jurisdictional and furthermore, according to the SFWMD Basis of Review, no state mitigation nor demonstration of avoidance and minimization would be required for impacts. As the subject property is located in a rural area that is predominantly agricultural use with a fringe of residential development, the overall location and landscape support would be moderate. The current and historical agricultural use of the subject property Page 116 of 456 Club at Indrio Creek Unincorporated St. Lucie County, Florida S of Indrio Rd., E of Emerson Ave. & W of Seminole Rd. March 2026 Page 9 of 26 has resulted in impacts to the wetlands’ hydrology and community structure via factors such as degradation of water quality, topographic alterations from use in row crops and lack of management. Additionally, Wetland 1 appears to have been artificially hydrated via an artesian well which has now ceased running, resulting in further hydrological alterations. These factors have resulted in less than optimal hydrology and community structure. Wildlife support has been negatively affected due to onsite conditions that include poor management and physical impediments but would maintain general “rural area” connectivity. Impedances to wildlife access would specifically be from factors such as heavy density of exotic vegetation onsite resulting in a closed canopy with limited access both on the ground and aerially for birds. However, offsite wildlife corridors remain available due to the general rural nature of lands within 2 miles of the subject property with some impedances to ground access because of perimeter ditching, fencing and roadways. The overall community structure of the onsite wetlands is also less than optimal. Species present in Wetland 1 consist predominantly of exotic vegetation such as torpedo grass, para grass and Brazilian pepper intermixed with species such as cat tails and primrose willow of which are associated with poor water quality. For additional information regarding permitting of potential impacts to this system at the local, state and federal levels see Section 4.0 Permit and Local Government Review of this EA Report. Existing Wetland Habitat FLUCCS/CLC Classifications Observed are as Follows: Wetland 1 (±1.88 ac) Wetland 1 is located in the southwestern portion of the subject property, specifically on Parcel 3. This wetland system is of poor quality and appears to have partially been formed as a result of two (2) flowing, high velocity, artesian wells. During the January 2025 assessment both wells were observed to be open and actively discharging a high volume of water. One (1) well was noted at the far north end of Wetland 1, acting as a headwater for this system, consistently discharging a large volume of water noted to be flowing south. A second well was observed near the center of the Wetland also Page 117 of 456 Club at Indrio Creek Unincorporated St. Lucie County, Florida S of Indrio Rd., E of Emerson Ave. & W of Seminole Rd. March 2026 Page 10 of 26 adding large quantities of water into the system. Both wells were capped with no further discharge as of the August 2025, site visit. During the August visit water was observed to have receded south with dry areas in the vicinity of the original “headwater” well. Soils continued to transition, becoming more sandy and losing their dark mucky surface in concert with notable loss of wetland plants such as cattails. As of February 2026, the wetland has further receded and appears to have hydrologically stabilized, with standing water and wetland vegetation remaining in the southern end, resulting in the final configuration as shown in this EA and approved by the SFWMD. Community structure of Wetland 1 is almost solely (±90%) exotic invasive species as well as species commonly associated with poor water quality such as torpedo grass, para grass, water lettuce, cattails, and Brazilian pepper. Minimal recruitment of native vegetation was noted; water quality is poor receiving agricultural runoff with plants indicative of a high nutrient environment and light penetration is limited. Topography within this system is also severely altered with notable areas of degraded farm furrows, which have further contributed to its ability to hold water artificially. Utilizing UMAM to score the condition of this wetland, function is estimated to be a 0.4. 619 FLUCCS/74 CLC: Exotic Wetland Hardwoods ±1.88 ac Representative Vegetation: Cuban club-rush (Cyperus blepharoleptos) – non-native Hygrophila (Hygrophila polysperma) – non-native Para grass (Urochloa mutica) – non-native Torpedo grass (Panicum repens) – non-native Water Spinach (Ipomoea aquatica) – non-native Pickerelweed (Pontederia cordata) – native Brazilian pepper (Schinus terebinthifolia) – non-native Phoenix date palm trees (Phoenix dactylifera) – non-native Cabbage palm trees (Sabal palmetto) – native Wetland 2 (±0.17 acres) Wetland 2 is located on Parcel 5. This is a freshwater marsh system that appears to have formed as result of seasonal conditions and high precipitation events causing overflow of the adjacent farm ditch. This system is of low to moderate ecological Page 118 of 456 Club at Indrio Creek Unincorporated St. Lucie County, Florida S of Indrio Rd., E of Emerson Ave. & W of Seminole Rd. March 2026 Page 11 of 26 condition. Community structure consists of both native and exotic species. Water quality is poor quality receiving untreated agricultural drainage. 641 FLUCCS/ 2121 CLC: Freshwater Marsh Representative Vegetation: Duck potato (Sagittaria lancifolia) – native Pickerelweed (Pontederia cordata) – native Cuban club-rush (Cyperus blepharoleptos) – non-native Torpedo grass (Panicum repens) – non-native 2.3 Other Surface Waters: The historic undulating topography resulting from the creation of beds and furrows on the site is still present. Additionally, the agricultural irrigation and drainage ditches as well as artesian wells are still present but capped as of August 2025 with the exception of one (1) well flowing at low velocity for cattle hydration. 510 FLUCCS, 183224 CLC: Artificial Waterway/Farm Ditch (±5.832 acres) 3.0 Wildlife Evaluation and Listed Fauna Survey As was done with regards to analysis of vegetation and habitat types, a similar approach was taken with regards to evaluation of onsite fauna, with the focus being the presence of listed species. Prior to conducting the site field work, regulatory databases such as U.S. Fish and Wildlife Information Planning, and Conservation System (IPAC), Florida Natural Areas Inventory (FNAI), FNAI Biodiversity Matrix, and Florida Department of Environmental Protection (FDEP) maps direct, were consulted with regards to any known, documented, or likely occurrences of listed species. Special note was taken with regard to listings of lands being within consultation areas for specific species, as well as any recorded documentation of listed species within or directly adjacent to the subject property. Habitat types on, adjacent, and within the general area or region were also closely reviewed to determine potential locations with increased likelihood of the occurrence of listed species. See Appendix C for the IPAC report. Page 119 of 456 Club at Indrio Creek Unincorporated St. Lucie County, Florida S of Indrio Rd., E of Emerson Ave. & W of Seminole Rd. March 2026 Page 12 of 26 3.1 US Fish and Wildlife Service (USFWS) Consultation Areas Based on databases review it was determined that the entire project area lies within the U.S. Fish and Wildlife Service (USFWS) Consultation area for the Audubon’s crested caracara (Caracara cheriway), Everglade’s snail kite (Rostrhamus sociabilis), and the Florida scrub-jay (Aphelocoma coerulescens). To require further action for listed species, such as initiation of formal consultation or survey, a development site must also contain or be in direct proximity to suitable habitat or known areas of occupation for that species. The scrub jay utilizes scrub habitat or areas immediately adjacent to scrub. The subject property contains no scrub habitat nor is it in proximity to scrub. The crested caracara occupies open pasture type lands with mature solitary palms. The subject property does contain pasture lands and maintains areas that could be suitable for foraging. The site does also contain mature cabbage palms but planted in linear rows or in clustered configurations along ditches. Additionally, these areas of trees and palms are further interspersed within dense patches of shrubs and exotic Brazilian pepper trees, being representative of the overall vegetative density on the subject property; high and making onsite habitats very marginal and unlikely to support nesting. Regardless, during this and all previous assessments conducted by Aquatic Research FL on the subject property, observations were made for current or historical nesting within any palms/trees being even marginally suitable for nesting. No evidence of current or historical nesting was noted (stomped fronds, pellets, bones or other signs of predation at base of trees). Utilizing the USFWS effect determination key for the crested caracara, site characteristics in concert with the below proposed construction conditions result in a no affect not likely to effect determination as required for project construction. Proposed conditions: • No construction during nesting season or • If construction is to occur during nesting season the completion of a pre construction survey to ensure no new/unexpected nesting has occurred nor birds observed on the property displaying nest building behaviors that would indicate the property to be within the territory of a nesting pair. Page 120 of 456 Club at Indrio Creek Unincorporated St. Lucie County, Florida S of Indrio Rd., E of Emerson Ave. & W of Seminole Rd. March 2026 Page 13 of 26 A technical consultation has been initiated was USFWS in order to verify that development of the subject property would result in a may affect not like to effect determination based on the aforementioned site and construction conditions. The Everglade’s snail kite utilizes freshwater marshes with a preference for vegetation such as saw grass and willow. While a small freshwater marsh is present on the subject property no snail shells were observed and species of vegetation are short herbaceous varieties like pickerelweed and torpedo grass which are not suitable for snail kites. Therefore, based on the USFWS determination keys for these species the subject property does not contain habitat suitable for these species and no survey or further consultation should be required. The subject property also lies within the Core Foraging Area for the wood stork. During the assessment it was determined that portions of the onsite ditches could be considered suitable for wood stork foraging. However as of March 9, 2026, the wood stork was federally delisted with protection mechanisms to be transferred to the states and agency such as Florida Fish and Wildlife Conservation Commission (FFWCC). The wood stork will remain federally protected under the Migratory Bird Act and Clean Water Act as well as be subject to 10 years of delisting monitoring efforts. During this transitional period protection mechanisms will likely remain and if that does apply, site development resulting in the filling of onsite ditches or smaller farm furrows could still require a wood stork forage and biomass analysis. Please see Section 3.2 below for additional species detail and survey requirements if the original protection mechanism remains. 3.2 Listed Fauna with a General Wildlife Survey Methods and Results During the field assessment pedestrian transects were made throughout the subject property to observe for the presence of any state or federal listed fauna species as well as wildlife in general. This included observations of individual animals as well as dens, burrows, roosting areas, or nests. Multiple linear transects as well as several cross transects were completed across all habitat areas. Distances between transects varied in the field depending on terrain, with larger distances between open areas with low lying vegetation, smaller in areas with dense vegetation or suspected listed species occupation. See Appendix A, Figures 4, 5, and 6 for Survey Transect Maps. Page 121 of 456 Club at Indrio Creek Unincorporated St. Lucie County, Florida S of Indrio Rd., E of Emerson Ave. & W of Seminole Rd. March 2026 Page 14 of 26 One hundred and twenty-two (122) transects were established to perform the habitat assessment and listed fauna species survey. The survey was conducted within ±49 acres (±38%) of the ±127.029-acre property. Total Acreage of Property ±127.029 ac Total Acreage of Property Surveyed ±49.0 ac Total Percent of Property Surveyed 38% Table 3.2.A: Approximate habitat acreage and survey acreage. The wildlife population was documented in the field by visual observation of individual animals as well as, tracks, scat, dens, foraging and nesting. A FFWCC compliant minimum 15% gopher tortoise and burrowing owl survey was also conducted. No owl or gopher tortoise burrows, or indication of usage was observed during the partial survey. No other listed species dens, nests, burrows, or roosting areas were observed. See tables below for the list of potential protected species and species observations (listed and non-listed). Species Common Name Federal Status State Listing Observation(s) Mammal Presence Felis concolor coryi Florida panther puma E E None Observed Peromyscus polionotus niveiiventris Southeastern beach mouse T T None Observed Bird Presence Athene cunicularia floridana Florida burrowing owl N T None Observed Laterallus jamaicensis plancus audobonii Eastern black rail T T None Observed Polyborus plancus audubonii crested caracara T T None Observed Rostrhamus sociabillis plumbeus Everglades snail kite T T None Observed Reptile Presence Alligator mississippiensis American alligator T T None Observed Drymarchon corais couperi Eastern indigo snake T T None Observed Gopherus polyphemus gopher tortoise C T None Observed Pituophis melanoleucus pine snake C T None Observed Insect Presence Anaea troglodyta oridalis Florida leafwing butterfly E E None Observed Page 122 of 456 Club at Indrio Creek Unincorporated St. Lucie County, Florida S of Indrio Rd., E of Emerson Ave. & W of Seminole Rd. March 2026 Page 15 of 26 Cyclargus thomasi bethunebakeri Miami blue butterfly E E None Observed Danus plexippus monarch butterfly E FE None Observed Migratory Bird Breeds Presence Aimophila aestivalis Bachman's sparrow BCC May 1 to Sep 30 None Observed Ardea herodias occidentalis great blue heron BCC Jan 1 to Dec 31 None Observed Arenaria interpres morinella ruddy turnstone BCC Breeds Elsewhere None Observed Calidris melanotos pectoral sandpiper BCC Breeds Elsewhere None Observed Calidris pusilla semipalmated sandpiper BCC Breeds Elsewhere None Observed Chaetura pelagica chimney swift BCC Mar 15 to Aug 26 None Observed Charadrius wilsonia Willson's plover BCC Apr 1 Aug 20 None Observed Dendroica discolor prairie warbler BCC May 1 to Jul 31 None Observed Egretta rufescens reddish egret BCC Mar 1 to Sep 15 None Observed Falco sparverius paulus American kestrel BCC Apr 1 to Aug 31 None Observed Fregata magnificens magnificent frigatebird BCC Oct 1 to Apr 30 None Observed Limnodromus griseus short-billed dowitcher BCC Breeds Elsewhere None Observed Passerina ciris painted bunting BCC Apr 25 to Aug 15 None Observed Sternula antillarum antillarum least tern BCC Apr 25 to Sep 5 None Observed Tringa avipes lesser yellowlegs BCC Breeds Elsewhere None Observed Table 3.2.B List of potential protected species and observations. Non-Listed Species Observation(s) Type Species Common Name Reptiles N/A N/A Mammals Rabbit scat N/A Aves Bubulcus ibis cattle egret Columbina passerina ground doves Charadrius vociferus killdear Table 3.2.C List of potential non-protected species and any observations. Page 123 of 456 Club at Indrio Creek Unincorporated St. Lucie County, Florida S of Indrio Rd., E of Emerson Ave. & W of Seminole Rd. March 2026 Page 16 of 26 3.2.1 Gopher Tortoise (Gopherus Polyphemus) The gopher tortoise (Gopherus Polyphemus) is state listed for protection as a threatened species. The Florida Fish and Wildlife Conservation Commission (FFWCC) is the agency responsible for protection of the gopher tortoise in Florida. The gopher tortoise is a moderate-sized, terrestrial turtle, averaging 9–11 inches in length when fully grown, though it can reach lengths of up to 15 inches. The life of a gopher tortoise revolves around its burrow(s) where gopher tortoises spend up to 80% of their time. Gopher tortoises prefer well-drained, sandy soils found in habitats such as longleaf pine sandhills, xeric oak hammocks, scrub, pine flatwoods, dry prairies, and coastal dunes. They are also found in a variety of disturbed habitats. Suitable gopher tortoise habitat contains well-drained sandy soils for digging burrows and nesting, abundant herbaceous plants for forage, and open, sunny areas with sparse canopy for nesting and basking. Information gathered during this assessment indicated that the subject property contained marginally suitable habitat for the gopher tortoise. On February 12, 2026, August 2025 and in January 2025 an FFWCC compliant 15% minimum habitat survey for gopher tortoise (Gopherus polyphemus) burrows were conducted. One hundred and twenty-two (122) transects were established to perform the habitat assessment and the gopher tortoise survey (Appendix A, Figures 4, 5, and 6). The survey was conducted within ±49 acres (±41%) of the ±119.147-acres of suitable habitat on the property. The ±7.882 acres of wetlands and onsite ditches were subtracted from the determination of suitable gopher tortoise habitat. The survey was conducted in accordance with the applicable regulatory guidance document. See Section 3.2.2 below for survey methodology and FFWCC formula for estimating tortoise populations during a partial survey. Total Acreage of Suitable Gopher Tortoise and Burrowing Owl Habitat ±119.147 Total Acreage of Suitable Gopher Tortoise and Burrowing Owl Habitat Surveyed ±49.0 Total Percent of Suitable Gopher Tortoise and Burrowing Owl Habitat Surveyed 41% Table 3.2.1 A: Acreage of suitable habitat and acres surveyed. Gopher tortoise surveys are valid for a period of 90 days for the purposes of regulatory submission. Page 124 of 456 Club at Indrio Creek Unincorporated St. Lucie County, Florida S of Indrio Rd., E of Emerson Ave. & W of Seminole Rd. March 2026 Page 17 of 26 3.2.1.1 Gopher Tortoise Survey Methodology Survey protocol is based on burrow survey methodology from the Florida Fish and Wildlife Conservation Commission Gopher Tortoise Permitting Guidelines, April 2008, Revised April 2023 Appendix 4 Burrow Survey Methods (Minimum of 15%). The project area is initially evaluated to determine the total acreage of suitable gopher tortoise habitat. This evaluation is done via review of documents and databases to assess the potential onsite features such as aerial signatures, soils maps, and agency reported FLUCCS/habitat mapping. Belt transects are then evenly distributed across all areas that have been deemed suitable habitat within the project’s impact areas, to achieve a minimum of 15% coverage. The maximum transect dimensions are not to exceed 250 meters (820 feet) long and 16 meters (52 feet) wide. Survey is then conducted throughout each established transect, covering 100% of the area within these transects. Generally, one (1) or more individuals are utilized during the field survey as recommended by the protocol stated above. The width between each observer ranges from one (1) meter to no more than ten (10) meters apart, depending on the density of the habitat. The edges of each transect are marked with flagging tape to ensure complete coverage if necessary, due to topography and/or vegetative density. Any burrows noted during the survey are recorded with a hand-held GPS and are also flagged in the field with high visibility flagging tape. Field notes are taken depicting the status of each burrow (i.e., potentially occupied or abandoned). According to the Gopher Tortoise Permitting Guidelines a potentially occupied burrow classification “combines the active and inactive categories and therefore includes burrows with obvious sign of use and those with minimal or no obvious sign of use.” An abandoned burrow “appears unused and dilapidated.” The classification of potentially occupied and abandoned burrows along with GPS locations of each burrow are depicted on an enclosed aerial as applicable. Additionally, for each belt transect raw data is reported in tabular format indicating transect dimensions, number of burrows and activity class, as well as total number of tortoises per acre. Once the survey is complete, the total onsite gopher tortoise population can be estimated by first calculating tortoises per acre and then applying that number to determine the total onsite population. Tortoises per acre are calculated as follows: Page 125 of 456 Club at Indrio Creek Unincorporated St. Lucie County, Florida S of Indrio Rd., E of Emerson Ave. & W of Seminole Rd. March 2026 Page 18 of 26 Total Potentially Occupied Burrows (0) Total Acres within Survey Area (49.0 acres) X 0.50 = (0) Tortoises per Acre Tortoise population is then estimated as follows: Tortoises per Acre (0) X Acres of Potential Gopher Tortoise Habitat (119.147) acres) = Estimated Tortoise Population (0 tortoise or 0 burrows) 3.2.2 Burrowing Owl (Athene cunicularia) The Florida burrowing owl is a state threatened species regulated by the FFWCC. Human activities have had a beneficial effect on the burrowing owl population in Florida. The conversion of native habitat to mowed grassy fields, cattle grazing, and wetland drainage have all contributed to increasing the species’ range. The burrowing owl inhabits open native prairies and cleared areas that offer an expanse of short, herbaceous groundcover. The typical breeding season for the Florida burrowing owl is February 15 to July 10, though owls can breed earlier or later. The owls dig burrows and nest underground; these burrows will be maintained and used again the following year. Juveniles will stay with the parents until they are able to self-sustain at 12 weeks old (FFWCC Burrowing Owl Species Conservation Measures and Guidelines). 3.2.2.1 Burrowing Owl (Athene cunicularia) Survey Methodology and Results Survey protocol was based on burrow survey methodology from the Florida Fish and Wildlife Conservation Commission Burrowing Owl Species Conservation Measures and Permitting Guidelines 2018. Transects are conducted throughout a minimum of 15% of the potential burrowing owl habitat using strip transects. Directional orientation of transects are based on parcel configuration, parcel boundaries, and vegetative density. Generally, one (1) or more individuals are utilized during the field survey as recommended by the protocol stated above. The width of each transect ranges from one (1) meter to no more than ten (10) meters apart, depending on the density of the habitat. The edges of each transect are marked with flagging tape to ensure complete coverage if deemed necessary due to topography and/or vegetative density. Any burrows noted during the survey are recorded with a hand-held GPS and are also flagged in the field with high visibility flagging tape. Care is taken to avoid all potentially occupied burrows by a radius of 10 feet. Field notes are taken Page 126 of 456 Club at Indrio Creek Unincorporated St. Lucie County, Florida S of Indrio Rd., E of Emerson Ave. & W of Seminole Rd. March 2026 Page 19 of 26 depicting the status of each burrow (i.e., active, inactive). The classification of potentially occupied burrows along with GPS locations of each burrow are depicted on an enclosed aerial as applicable. No burrowing owls or burrows were observed during the 15% minimum habitat survey. 3.2.3 Wood Stork (Mycteria americana) The wood stork is primarily associated with freshwater and estuarine habitats using them for nesting, roosting, and foraging. Wood storks occur in a wide variety of wetland habitats. Typical foraging sites for wood stork include freshwater marshes and stock ponds, shallow, seasonally flooded roadside and agricultural ditches, narrow tidal creeks and shallow tidal pools, managed impoundments, and depressions in cypress heads and swamp sloughs. There is no designated critical habitat for the wood stork. Rather a 29.9-kilometer (18.6-mile) core foraging area (CFA) around all known wood stork colonies in south Florida is used to determine if a project may affect wood storks. Database review indicates that the subject property is located within core foraging areas. Site review would appear to indicate that portions of the onsite ditches are suitable for wood stork forage. Therefore, as discussed in Section 3.1 of this report, if protection mechanisms remain for this species post delisting, alteration to the property that encompasses filling of ditches or waterbodies considered suitable for wood stork forage could require assessment for loss of wood stork forage and subsequent mitigation for calculated loss. The USFWS believes loss of suitable ditches and wetlands within these CFAs may reduce foraging opportunities for the wood stork. To minimize adverse effects to the wood stork, compensation may still be required to be provided for impacts to foraging habitat. If required, compensation should consider wetland type, location, function, and value (hydrology, vegetation, prey utilization) to ensure that wetland functions lost due to the project are adequately offset. Wetlands offered as compensation should be of the same hydroperiod and located within the CFAs of the affected wood stork colonies. To determine the effect of development actions on the wood stork in south Florida, the USFWS has developed a functional assessment known as the “Wood Stork Foraging Page 127 of 456 Club at Indrio Creek Unincorporated St. Lucie County, Florida S of Indrio Rd., E of Emerson Ave. & W of Seminole Rd. March 2026 Page 20 of 26 Habitat Assessment Methodology” (Methodology) This Methodology can be used to estimate the biomass of wood stork forage provided per unit quantity of wetland habitat. The assessment can be applied to both wetlands/farm ditches being lost by a development project and the wetlands or littoral areas around lakes proposed as mitigation. Parameters used in the estimation of wood stork prey biomass are: 1. Vegetation Density 2. Wetland Hydroperiod 3. Prey Size Suitability 4. Competition with other wading bird species for forage. (USFWS, Multi Species Recovery Plan Wood Stork, and USFWS, Wood Stork Forage Habitat Assessment Methodology July 2012). If the wood stork assessment determines forage area is to be lost in association with development of the Club at Indrio Creek Project, mitigation for those losses can be done onsite via preservation or creation of other forage areas or offsite via the purchase of credits from a wetland mitigation bank offering wood stork credits. The creation of an onsite lake with a vegetated littoral shelf could also be used to partially or fully offset onsite forage impacts. 3.3 Conservation Lands As part of the assessment, agency databases were searched for conservation lands located within or adjacent to the subject property. Based on the database review no conservation areas are within 1 mile of the subject property. 4.0 Permit and Local Government Review As part of the assessment, local land development codes were reviewed with regard to environmental requirements and agency databases were searched for permits associated with the subject property. See below for relevant information regarding the subject property. 4.1 Permit Review As part of the assessment agency databases were searched for associated environmental permits that cover the subject property. The property has two (2) active consumptive use permits issued from South Florida Water Management District (SFWMD) and one (1) application for a formal wetland determination. Page 128 of 456 Club at Indrio Creek Unincorporated St. Lucie County, Florida S of Indrio Rd., E of Emerson Ave. & W of Seminole Rd. March 2026 Page 21 of 26 Permit 56-00936-W is for the annual allocation of 32 million gallons per year from a Ft. Pierce Farms Water Control District (FPFWCD) canal and the aquifer for agricultural irrigation. As of the date of this report, the permit’s expiration date is 07/18/2025. Permit 56-00723 is for annual allocation of 7.7 million gallons per year from the surficial aquifer system via one (1) existing withdrawal facility. The purpose is for nursery irrigation of 7 acres of palm trees using a sprinkler irrigation system. As of the date of this report, the permit’s expiration date is 03/26/2029. A formal wetland determination is in progress with SFWMD, Application Number 260106-60453. On February 12, 2026, the site was reviewed by SFWMD with both the extents of onsite wetlands and other surface water finalized. Survey has been completed, demonstrating the approved limits of these features and can be found in Appendix D. All documents have been provided to SFWMD for review and issuance of the approved formal determination letter should be forthcoming. 4.2. Local Government Review and Wetland Impact Permitting The subject property contains two (2) low quality isolated state jurisdictional wetlands. Per the St. Lucie County Comprehensive Plan, both Wetlands 1 and 2 are less than 5 acres in size and would be considered Category III Wetlands. St. Lucie County defined Category III Wetlands require a 25-foot buffer and can be impacted if deemed necessary to develop a site and avoidance and minimization can be demonstrated. Based on the low ecological condition of Wetland 1, impacts are feasible at both the County and the State levels. Mitigation would be required for impacts and can be provided via onsite enhancement or the purchase of wetland credits from a mitigation bank with a service area that covers the subject property. Wetland 2 (±0.17 acres), being under 0.5 acres in size, would be considered non county jurisdictional in accordance with the Comprehensive Plan and LDC. Wetlands under 0.5 acres in size, per the SFWMD Basis of Review, further require no mitigation at the state level nor demonstration of avoidance and minimization of impacts. Any proposed wetland impacts will require obtaining a State Environmental Resource Permit (ERP) and St. Lucie County Wetland Waiver, process of which includes, demonstration of avoidance and minimization of impacts and providing compensatory Page 129 of 456 Club at Indrio Creek Unincorporated St. Lucie County, Florida S of Indrio Rd., E of Emerson Ave. & W of Seminole Rd. March 2026 Page 22 of 26 mitigation for impacts to all non isolated wetlands and isolated wetlands over 0.5 acres in size. As discussed in Section 2.2 of this report, Wetland 1 was scored a 0.4 utilizing the Unifor Mitigation Assessment Method (UMAM). Additionally, since the subject property contains wetlands, any site development application will require the submission of a sixteen (16) part Environmental Impact Report (EIR) to the St. Lucie County Environmental Resources Department (ERD). A protected tree survey will also be required to develop the property. Avoidance of protected trees to the greatest extent possible must be demonstrated. Trees that must be removed for development will require mitigation in accordance with the St. Lucie County LDC. Mitigation options include preservation of trees on site, relocation of trees onsite or to an offsite County approved park or protected lands, planting of trees onsite, payment into the County’s tree fund, or the creation of an onsite tree preservation area. 5.0 Soils Based on a review of the Soil Survey Geographic and the Web Soil Survey Databases, hydric and non-hydric soil types exist on the site. No soil borings or geotechnical analysis was conducted as part of this assessment. See Appendix A, Figure 8 for depiction of onsite soil mapping units. Soil type are as follows: Chobee loamy sand, frequently ponded, 0 to 1 percent slope (hydric) – 11 Hilolo loamy sand, 0 to 2 percent slopes (hydric) – 16 Lawnwood and Myakka sands (non-hydric) – 21 Pineda sand, 0 to 2 percent slopes (hydric) – 32 Riviera fine sand, 0 to 2 percent slopes (hydric) – 38 Wabasso sand, 0 to 2 percent slopes (hydric) – 48 6.0 Summary On February 12, 2026, an environmental assessment was conducted by the qualified biologists of Aquatic Research FL on the ±127.029-acre Club at Indrio Creek subject property located south of Indrio Road/SR-614, east of Emerson Avenue, and west of Seminole Road within unincorporated St. Lucie County Florida. Assessments were also Page 130 of 456 Club at Indrio Creek Unincorporated St. Lucie County, Florida S of Indrio Rd., E of Emerson Ave. & W of Seminole Rd. March 2026 Page 23 of 26 conducted on the subject property in August and January of 2025. The property is an inactive tree farm currently being utilized for cattle. No native upland habitat is located within the limits of the subject property. Two (2) state jurisdictional wetlands have been delineated by Aquatic Research FL and further verified by SFWMD as part of the formal process (Application Number 260106-60453). Both wetlands meet the classification of a St Lucie County Category III Wetland. Category III Wetlands may be impacted if avoidance and minimization are demonstrated and systems are shown to provide less ecological function than mitigation would provide. Any wetland impacts proposed as part of site development will require obtaining a state Environmental Resource Permit (ERP) and County Wetland Waiver. Additionally, for impacts to onsite isolated wetlands over 0.5 acres in size, compensatory mitigation is required. Mitigation can be done via the purchase of credits from a wetland mitigation bank. No listed flora species were identified on the subject property. A FFWCC compliant 15% gopher tortoise and burrowing owl survey were conducted. No tortoise or owl burrows were observed. The subject property contains waters (farm ditches) suitable for wood stork foraging. The woods stork recently has been federally delisted and is in a transitional phase, with protection transferring to state agencies such as FFWCC. If current protection measures remain in place, a foraging assessment with mitigation for loss of suitable waters will be required as part of site development. The subject property is within the USFWS Consultation area for the federally protected crested caracara. A technical consultation has been requested with USFWS to verify site development with the implementation of pre construction conditions shall result in a no affect not likely to effect determination. Recommendations include either no construction during nesting season OR completion of a pre construction survey if work is to be done during nesting season to ensure no unexpected nesting or territorial occupation. Page 131 of 456 Club at Indrio Creek Unincorporated St. Lucie County, Florida S of Indrio Rd., E of Emerson Ave. & W of Seminole Rd. March 2026 Page 24 of 26 No other listed species dens, nests, burrows, or roosting areas were observed on the subject property. A review of the South Florida Water Management District (SFWMD) epermitting database indicates active Consumptive Use permits associated with the subject property as well as a formal wetland determination in process. Page 132 of 456 Club at Indrio Creek Unincorporated St. Lucie County, Florida S of Indrio Rd., E of Emerson Ave. & W of Seminole Rd. March 2026 Page 25 of 26 7.0 Transect Data Page 133 of 456 Club at Indrio Creek Unincorporated St. Lucie County, Florida S of Indrio Rd., E of Emerson Ave. & W of Seminole Rd. March 2026 Page 26 of 26 Page 134 of 456 Appendix A Site Maps Page 135 of 456 Pg. 1 of 8 Location Map Figure 1 Image: Google Earth 2024 Club at Indrio Creek S of Indrio Rd., E of Emerson Ave., & W of Seminole Rd., Unincorporated St. Lucie County, Florida Section 14, Township 34 S, Range 39 E Em e r s o n A v e n u e SR-614/Indrio Rd Se m i n o l e R o a d Environmental Consulting Aquatic ResearchFL.com Wetlands, Protected Species, & Permitting Page 136 of 456 Pg. 2 of 8 Site Map Figure 2 Image: Google Earth /2024 LEGEND Property Boundary (±127.029 acres) A Map ID Parcel ID Address 1 1314-323-0002-000-3 Emerson Ave. 2 1314-331-0001-000-1 Emerson Ave. 3 1314-313-0000-000-8 Seminole Rd. 4 1314-342-0001-000-5 Seminole Rd. 5 1314-341-0000-000-5 Seminole Rd. 6 1323-211-0005-000-8 Seminole Rd. Em e r s o n A v e n u e SR-614/Indrio Rd Se m i n o l e R o a d Parcel 1 Parcel 2 Parcel 3 Pa r c e l 4 Pa r c e l 5 Parcel 6 Environmental Consulting Aquatic ResearchFL.com Wetlands, Protected Species, & Permitting Club at Indrio Creek S of Indrio Rd., E of Emerson Ave., & W of Seminole Rd., Unincorporated St. Lucie County, Florida Section 14, Township 34 S, Range 39 E Page 137 of 456 Pg. 3 of 7 Agency Reported Land Use Map Figure 3 Image: Florida Department of Environmental Protection Data: Florida Land Cover Classification System Definitions for the Cooperative Land Cover Map v2.3 Pg. 3 of 8 LEGEND Property Boundary (±127.029 acres) Onsite FLUCCS Classification 2210: Citrus Groves Offsite FLUCCS Classification 2110: Improved Pasture 1110: Single Family Homes 5120: Channelized Waterways, Canals 4340: Upland Mixed Coniferous / Hardwood 4200: Upland Hardwood Forests FLUCCS=Florida Landuse Classification Code System 2210 2110 2110 Parcel 1 Parcel 2 Parcel 3 Parcel 4 Parcel 5 Parcel 6 2210 2210 2210 2210 2210 1110 4340 4200 5120 Environmental Consulting Aquatic ResearchFL.com Wetlands, Protected Species, & Permitting Club at Indrio Creek S of Indrio Rd., E of Emerson Ave., & W of Seminole Rd., Unincorporated St. Lucie County, Florida Section 14, Township 34 S, Range 39 E Page 138 of 456 Pg. 4 of 8 General Wildlife Survey including Listed Flora and Fauna, Gopher Tortoise and Burrowing Owl Survey Transect Map Figure 4 Image: Google Earth – Date 01/21/2022 Data: Aquatic Research Monitoring, Equipment, - Deployment LLC LEGEND Property Boundary (±127.029 acres) Wildlife Survey Transects 1-34 Tr a n s e c t s 3 - 4 Transects 5 - 6 Transects 11 - 12 ±45 0 ’ Transects 1 - 2 ±2,600’ Transects 13 - 14 Tr a n s e c t s 1 5 - 16 Tr a n s e c t s 1 7 - 18 Tr a n s e c t s 1 9 - 20 Tr a n s e c t s 2 1 - 22 Tr a n s e c t s 2 3 - 24 Tr a n s e c t s 2 5 - 26 Tr a n s e c t s 2 7 - 28 Tr a n s e c t s 2 9 - 30 Transects 31 - 32 Transects 33 - 34 Parcel 1 Parcel 2 Parcel 3 Parcel 4 Parcel 5 Environmental Consulting Aquatic ResearchFL.com Wetlands, Protected Species, & Permitting Club at Indrio CreekS of Indrio Rd., E of Emerson Ave., & W of Seminole Rd., Unincorporated St. Lucie County, Florida Section 14, Township 34 S, Range 39 E Total Acreage of Suitable Gopher Tortoise and Burrowing Owl Habitat ±119.147 Total Acreage of Suitable Gopher Tortoise and Burrowing Owl Habitat Surveyed ±49.0 Total Percent of Suitable Gopher Tortoise and Burrowing Owl Habitat Surveyed 41% Total Acreage of Property ±127.029 ac Total Acreage of Property Surveyed ±49.0 ac Total Percent of Property Surveyed 38% Page 139 of 456 Pg. 5 of 8 Figure 5 Image: Google Earth – Date 01/21/2022 Data: Aquatic Research Monitoring, Equipment, - Deployment LLC LEGEND Property Boundary (±127.029 acres) Wildlife Survey Transects 35-64 ±1, 4 5 0 ’ ±1,200’ Transects 35 - 36Transects 37 - 38 Tr a n s e c t s 3 9 - 40 Tr a n s e c t s 4 1 - 42 Tr a n s e c t s 4 3 - 44 Tr a n s e c t s 4 5 - 46 Tr a n s e c t s 4 7 - 48 Tr a n s e c t s 4 9 - 50 Transects 51 - 52 Transects 53 - 54 Tr a n s e c t s 5 5 - 56 Tr a n s e c t s 5 7 - 58 Tr a n s e c t s 5 9 - 60 Tr a n s e c t s 6 1 - 62 Tr a n s e c t s 6 3 - 64 Parcel 3 Parcel 4 Parcel 5 Parcel 6 Parcel 1 Parcel 2 General Wildlife Survey including Listed Flora and Fauna, Gopher Tortoise and Burrowing Owl Survey Transect Map Environmental Consulting Aquatic ResearchFL.com Wetlands, Protected Species, & Permitting Club at Indrio CreekS of Indrio Rd., E of Emerson Ave., & W of Seminole Rd., Unincorporated St. Lucie County, Florida Section 14, Township 34 S, Range 39 E Page 140 of 456 Pg. 6 of 8 Figure 6 Image: Google Earth – Date 01/21/2022 Data: Aquatic Research Monitoring, Equipment, - Deployment LLC LEGEND Property Boundary (±127.029 acres) Wildlife Survey Transects 65-122 ±1, 8 0 0 ’ ±1,200’ Transects 35 - 36 Tr a n s e c t s 6 1 - 62 Tr a n s e c t s 6 3 - 64 Transects 65 - 66 Transects 67 - 68 Transects 69 - 70 Transects 71 - 72 Transects 73 - 74 Tr a n s e c t s 7 5 - 76 Transects 79 - 80 Transects 81 - 82 Tr a n s e c t s 8 5 - 86 Transects 87 - 88 Tr a n s e c t s 8 9 - 90 Transects 91 - 92 Transects 93 - 94 Transects 95 - 96 Tr a n s e c t s 9 9 - 10 0 Tr a n s e c t s 1 0 2 - 10 3 Transects 103 - 104 Transects 105 - 106 Tr a n s e c t s 1 0 7 - 10 8 Transects 109 - 110 Transects 111 - 112 Transects 113 - 114 Transects 117 - 118 Transects 119 - 120Transects 121 - 122 Parcel 2 Pa r c e l 3 Parcel 4 Parcel 5 Parcel 6 General Wildlife Survey including Listed Flora and Fauna, Gopher Tortoise and Burrowing Owl Survey Transect Map X Environmental Consulting Aquatic ResearchFL.com Wetlands, Protected Species, & Permitting Club at Indrio CreekS of Indrio Rd., E of Emerson Ave., & W of Seminole Rd., Unincorporated St. Lucie County, Florida Section 14, Township 34 S, Range 39 E Page 141 of 456 Pg. 7 of 8 Existing Habitat/FLUCCS-CLC Map Figure 7 Image: Google Earth – Date 01/21/2022 Data: Aquatic Research Monitoring, Equipment, & Deployment LLC LEGEND Property Boundary (±127.029 acres) 2241 FLUCCS/ 183224 CLC: Abandoned Tree Nursery (±119.147 acres) 510 FLUCCS/422 CLC: Farm Ditches (±5.832 acres) Wetland 1 (±1.88 acres) 619 FLUCCS/74 CLC: Exotic Wetland Hardwoods Wetland 2 (±0.17 acres) 641 FLUCCS/ 2121 CLC: Freshwater Marsh FLUCCS=Florida Landuse Classification Code SystemCLC=Cooperative Landuse Classification Wetland 1 Wetland 2 Environmental Consulting Aquatic ResearchFL.com Wetlands, Protected Species, & Permitting Club at Indrio CreekS of Indrio Rd., E of Emerson Ave., & W of Seminole Rd., Unincorporated St. Lucie County, Florida Section 14, Township 34 S, Range 39 E Page 142 of 456 Pg. 8 of 8 Soil(s) Map Figure 8 Image: USDA Data: WSS & SSURGO Soil Survey LEGEND Property Boundary (±127.029 acres) 21 32 48 38 11 16 32 48 Hydric Hydric Non-Hydric Hydric Hydric Hydric Em e r s o n A v e n u e Se m i n o l e R o a d 38 21 1611 48 48 16 48 Club at Indrio Creek S of Indrio Rd., E of Emerson Ave., & W of Seminole Rd., Unincorporated St. Lucie County, Florida Section 14, Township 34 S, Range 39 E Environmental Consulting Aquatic ResearchFL.com Wetlands, Protected Species, & Permitting Page 143 of 456 Appendix B Site Photographs Page 144 of 456 Club at Indrio Creek Unincorporated St. Lucie County, Florida S of Indrio Rd., E of Emerson Ave. & W of Seminole Rd. March 2026 Pg 1 of 1 Representative Photographs Upland Area Wetland 1 Wetland 2 Page 145 of 456 Appendix C Information for Planning and Consultation (IPAC) Page 146 of 456 IPaC resource list This report is an automatically generated list of species and other resources such as critical habitat (collectively referred to as trust resources) under the U.S. Fish and Wildlife Service's (USFWS) jurisdiction that are known or expected to be on or near the project area referenced below. The list may also include trust resources that occur outside of the project area, but that could potentially be directly or indirectly affected by activities in the project area. However, determining the likelihood and extent of effects a project may have on trust resources typically requires gathering additional site-specific (e.g., vegetation/species surveys) and project-specific (e.g., magnitude and timing of proposed activities) information. Below is a summary of the project information you provided and contact information for the USFWS office(s) with jurisdiction in the defined project area. Please read the introduction to each section that follows (Endangered Species, Migratory Birds, USFWS Facilities, and NWI Wetlands) for additional information applicable to the trust resources addressed in that section. Location St. Lucie County, Florida Local office Florida Ecological Services Field Office  (352) 448-9151  (772) 562-4288  fw4flesregs@fws.gov 777 37th St Suite D-101 Vero Beach, FL 32960-3559 https:/ / www.fws.gov/ office/ florida-ecological-services U.S. Fish & Wildlife ServiceIPaC 3/22/26, 10:53 AM IPaC: Explore Location resources https://ipac.ecosphere.fws.gov/location/KDZIO6CFHFFH5LD5XG2D3KMFHY/resources 1/11Page 147 of 456 Endangered species This resource list is for informational purposes only and does not constitute an analysis of project level impacts. The primary information used to generate this list is the known or expected range of each species. Additional areas of influence (AOI) for species are also considered. An AOI includes areas outside of the species range if the species could be indirectly affected by activities in that area (e.g., placing a dam upstream of a fish population even if that fish does not occur at the dam site, may indirectly impact the species by reducing or eliminating water flow downstream). Because species can move, and site conditions can change, the species on this list are not guaranteed to be found on or near the project area. To fully determine any potential effects to species, additional site-specific and project-specific information is often required. Section 7 of the Endangered Species Act requires Federal agencies to "request of the Secretary information whether any species which is listed or proposed to be listed may be present in the area of such proposed action" for any project that is conducted, permitted, funded, or licensed by any Federal agency. A letter from the local office and a species list which fulfills this requirement can only be obtained by requesting an official species list from either the Regulatory Review section in IPaC (see directions below) or from the local field office directly. For project evaluations that require USFWS concurrence/review, please return to the IPaC website and request an official species list by doing the following: 1. Draw the project location and click CONTINUE. 2. Click DEFINE PROJECT. 3. Log in (if directed to do so). 4. Provide a name and description for your project. 5. Click REQUEST SPECIES LIST. Listed species and their critical habitats are managed by the Ecological Services Program of the U.S. Fish and Wildlife Service (USFWS) and the fisheries division of the National Oceanic and Atmospheric Administration (NOAA Fisheries ). Species and critical habitats under the sole responsibility of NOAA Fisheries are not shown on this list. Please contact NOAA Fisheries for species under their jurisdiction. 1. Species listed under the Endangered Species Act are threatened or endangered; IPaC also shows species that are candidates, or proposed, for listing. See the listing status page for more information. IPaC only shows species that are regulated by USFWS (see FAQ). 2. NOAA Fisheries, also known as the National Marine Fisheries Service (NMFS), is an office of the National Oceanic and Atmospheric Administration within the Department of Commerce. The following species are potentially affected by activities in this location: Mammals Birds 1 2 NAME STATUS Florida Panther Puma (=Felis) concolor coryi Wherever found No critical habitat has been designated for this species. https://ecos.fws.gov/ecp/species/1763 Endangered Puma (=mountain Lion) Puma (=Felis) concolor (all subsp. except coryi) No critical habitat has been designated for this species. https://ecos.fws.gov/ecp/species/6049 SAT Southeastern Beach Mouse Peromyscus polionotus niveiventris Wherever found No critical habitat has been designated for this species. https://ecos.fws.gov/ecp/species/3951 Threatened NAME STATUS Crested Caracara (audubon's) [fl Dps] Caracara plancus audubonii No critical habitat has been designated for this species. https://ecos.fws.gov/ecp/species/8250 Threatened 3/22/26, 10:53 AM IPaC: Explore Location resources https://ipac.ecosphere.fws.gov/location/KDZIO6CFHFFH5LD5XG2D3KMFHY/resources 2/11Page 148 of 456 Reptiles Insects Flowering Plants Critical habitats Potential effects to critical habitat(s) in this location must be analyzed along with the endangered species themselves. There are no critical habitats at this location. You are still required to determine if your project(s) may have effects on all above listed species. Bald & Golden Eagles Eastern Black Rail Laterallus jamaicensis jamaicensis Wherever found No critical habitat has been designated for this species. https://ecos.fws.gov/ecp/species/10477 Threatened Everglade Snail Kite Rostrhamus sociabilis plumbeus Wherever found There is final critical habitat for this species. Your location does not overlap the critical habitat. https://ecos.fws.gov/ecp/species/7713 Endangered NAME STATUS American Alligator Alligator mississippiensis Wherever found No critical habitat has been designated for this species. https://ecos.fws.gov/ecp/species/776 SAT Eastern Indigo Snake Drymarchon couperi Wherever found No critical habitat has been designated for this species. https://ecos.fws.gov/ecp/species/646 Threatened NAME STATUS Monarch Butterfly Danaus plexippus Wherever found There is proposed critical habitat for this species. Your location does not overlap the critical habitat. https://ecos.fws.gov/ecp/species/9743 Proposed Threatened NAME STATUS Fragrant Prickly-apple Cereus eriophorus var. fragrans No critical habitat has been designated for this species. https://ecos.fws.gov/ecp/species/982 Endangered Tiny Polygala Polygala smallii No critical habitat has been designated for this species. https://ecos.fws.gov/ecp/species/996 Endangered Bald and Golden Eagles are protected under the Bald and Golden Eagle Protection Act and the Migratory Bird Treaty Act (MBTA) . Any person or organization who plans or conducts activities that may result in impacts to Bald or Golden Eagles, or their habitats, should follow appropriate regulations and consider implementing appropriate avoidance and minimization measures, as described in the various links on this page. Additional information can be found using the following links: Eagle Management https://www.fws.gov/program/eagle-management 2 1 3/22/26, 10:53 AM IPaC: Explore Location resources https://ipac.ecosphere.fws.gov/location/KDZIO6CFHFFH5LD5XG2D3KMFHY/resources 3/11Page 149 of 456 There are Bald Eagles and/or Golden Eagles in your project area. Measures for Proactively Minimizing Eagle Impacts For information on how to best avoid and minimize disturbance to nesting bald eagles, please review the National Bald Eagle Management Guidelines. You may employ the timing and activity-specific distance recommendations in this document when designing your project/activity to avoid and minimize eagle impacts. For bald eagle information specific to Alaska, please refer to Bald Eagle Nesting and Sensitivity to Human Activity. The FWS does not currently have guidelines for avoiding and minimizing disturbance to nesting Golden Eagles. For site-specific recommendations regarding nesting Golden Eagles, please consult with the appropriate Regional Migratory Bird Office or Ecological Services Field Office. If disturbance or take of eagles cannot be avoided, an incidental take permit may be available to authorize any take that results from, but is not the purpose of, an otherwise lawful activity. For assistance making this determination for Bald Eagles, visit the Do I Need A Permit Tool. For assistance making this determination for golden eagles, please consult with the appropriate Regional Migratory Bird Office or Ecological Services Field Office. Ensure Your Eagle List is Accurate and Complete If your project area is in a poorly surveyed area in IPaC, your list may not be complete and you may need to rely on other resources to determine what species may be present (e.g. your local FWS field office, state surveys, your own surveys). Please review the Supplemental Information on Migratory Birds and Eagles, to help you properly interpret the report for your specified location, including determining if there is sufficient data to ensure your list is accurate. For guidance on when to schedule activities or implement avoidance and minimization measures to reduce impacts to bald or golden eagles on your list, see the "Probability of Presence Summary" below to see when these bald or golden eagles are most likely to be present and breeding in your project area. Review the FAQs The FAQs below provide important additional information and resources. BREEDING SEASON Probability of Presence Summary The graphs below provide our best understanding of when birds of concern are most likely to be present in your project area. This information can be used to tailor and schedule your project activities to avoid or minimize impacts to birds. Please make sure you read "Supplemental Information on Migratory Birds and Eagles", specifically the FAQ section titled "Proper Interpretation and Use of Your Migratory Bird Report" before using or attempting to interpret this report. Probability of Presence () Each green bar represents the bird's relative probability of presence in the 10km grid cell(s) your project overlaps during a particular week of the year. (A year is represented as 12 4-week months.) A taller bar indicates a higher probability of species presence. The survey effort (see below) can be used to establish a level of confidence in the presence score. One can have higher confidence in the presence score if the corresponding survey effort is also high. How is the probability of presence score calculated? The calculation is done in three steps: 1. The probability of presence for each week is calculated as the number of survey events in the week where the species was detected divided by the total number of survey events for that week. For example, if in week 12 there were 20 survey events and the Spotted Towhee was found in 5 of them, the probability of presence of the Spotted Towhee in week 12 is 0.25. 2. To properly present the pattern of presence across the year, the relative probability of presence is calculated. This is the probability of presence divided by the maximum probability of presence across all weeks. For example, imagine the probability of presence in week 20 for the Spotted Towhee is 0.05, and that the probability of presence at week 12 (0.25) is the maximum of any week of the year. The relative probability of presence on week 12 is 0.25/0.25 = 1; at week 20 it is 0.05/0.25 = 0.2. 3. The relative probability of presence calculated in the previous step undergoes a statistical conversion so that all possible values fall between 0 and 10, inclusive. This is the probability of presence score. To see a bar's probability of presence score, simply hover your mouse cursor over the bar. Breeding Season () Measures for avoiding and minimizing impacts to birds https://www.fws.gov/library/collections/avoiding-and-minimizing-incidental- take-migratory-birds Nationwide avoidance and minimization measures for birds https://www.fws.gov/sites/default/files/documents/nationwide-standard- conservation-measures.pdf Supplemental Information for Migratory Birds and Eagles in IPaC https://www.fws.gov/media/supplemental-information-migratory- birds-and-bald-and-golden-eagles-may-occur-project-action NAME Bald Eagle Haliaeetus leucocephalus This is not a Bird of Conservation Concern (BCC) in this area, but warrants attention because of the Eagle Act or for potential susceptibilities in offshore areas from certain types of development or activities. Breeds Sep 1 to Jul 31 3/22/26, 10:53 AM IPaC: Explore Location resources https://ipac.ecosphere.fws.gov/location/KDZIO6CFHFFH5LD5XG2D3KMFHY/resources 4/11Page 150 of 456 no data survey effort breeding season probability of presence Yellow bars denote a very liberal estimate of the time-frame inside which the bird breeds across its entire range. If there are no yellow bars shown for a bird, it does not breed in your project area. Survey Effort () Vertical black lines superimposed on probability of presence bars indicate the number of surveys performed for that species in the 10km grid cell(s) your project area overlaps. The number of surveys is expressed as a range, for example, 33 to 64 surveys. To see a bar's survey effort range, simply hover your mouse cursor over the bar. No Data () A week is marked as having no data if there were no survey events for that week. Survey Timeframe Surveys from only the last 10 years are used in order to ensure delivery of currently relevant information. The exception to this is areas off the Atlantic coast, where bird returns are based on all years of available data, since data in these areas is currently much more sparse. SPECIES JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC Bald Eagle Non-BCC Vulnerable Bald & Golden Eagles FAQs What does IPaC use to generate the potential presence of bald and golden eagles in my specified location? The potential for eagle presence is derived from data provided by the Avian Knowledge Network (AKN). The AKN data is based on a growing collection of survey, banding, and citizen science datasets and is queried and filtered to return a list of those birds reported as occurring in the 10km grid cell(s) which your project intersects, and that have been identified as warranting special attention because they are an eagle (Bald and Golden Eagle Protection Act requirements may apply). Proper interpretation and use of your eagle report On the graphs provided, please look carefully at the survey effort (indicated by the black vertical line) and for the existence of the "no data" indicator (a red horizontal line). A high survey effort is the key component. If the survey effort is high, then the probability of presence score can be viewed as more dependable. In contrast, a low survey effort line or no data line (red horizontal) means a lack of data and, therefore, a lack of certainty about presence of the species. This list is not perfect; it is simply a starting point for identifying what birds have the potential to be in your project area, when they might be there, and if they might be breeding (which means nests might be present). The list and associated information help you know what to look for to confirm presence and helps guide you in knowing when to implement avoidance and minimization measures to eliminate or reduce potential impacts from your project activities or get the appropriate permits should presence be confirmed. How do I know if eagles are breeding, wintering, or migrating in my area? To see what part of a particular bird's range your project area falls within (i.e. breeding, wintering, migrating, or resident), you may query your location using the RAIL Tool and view the range maps provided for birds in your area at the bottom of the profiles provided for each bird in your results. If an eagle on your IPaC migratory bird species list has a breeding season associated with it (indicated by yellow vertical bars on the phenology graph in your “IPaC PROBABILITY OF PRESENCE SUMMARY” at the top of your results list), there may be nests present at some point within the timeframe specified. If "Breeds elsewhere" is indicated, then the bird likely does not breed in your project area. Interpreting the Probability of Presence Graphs Each green bar represents the bird's relative probability of presence in the 10km grid cell(s) your project overlaps during a particular week of the year. A taller bar indicates a higher probability of species presence. The survey effort can be used to establish a level of confidence in the presence score. How is the probability of presence score calculated? The calculation is done in three steps: The probability of presence for each week is calculated as the number of survey events in the week where the species was detected divided by the total number of survey events for that week. For example, if in week 12 there were 20 survey events and the Spotted Towhee was found in 5 of them, the probability of presence of the Spotted Towhee in week 12 is 0.25. To properly present the pattern of presence across the year, the relative probability of presence is calculated. This is the probability of presence divided by the maximum probability of presence across all weeks. For example, imagine the probability of presence in week 20 for the Spotted Towhee is 0.05, and that the probability of presence at week 12 (0.25) is the maximum of any week of the year. The relative probability of presence on week 12 is 0.25/0.25 = 1; at week 20 it is 0.05/0.25 = 0.2. The relative probability of presence calculated in the previous step undergoes a statistical conversion so that all possible values fall between 0 and 10, inclusive. This is the probability of presence score. Breeding Season () Yellow bars denote a very liberal estimate of the time-frame inside which the bird breeds across its entire range. If there are no yellow bars shown for a bird, it does not breed in your project area. Survey Effort () Vertical black lines superimposed on probability of presence bars indicate the number of surveys performed for that species in the 10km grid cell(s) your project area overlaps. No Data () A week is marked as having no data if there were no survey events for that week. Survey Timeframe 3/22/26, 10:53 AM IPaC: Explore Location resources https://ipac.ecosphere.fws.gov/location/KDZIO6CFHFFH5LD5XG2D3KMFHY/resources 5/11Page 151 of 456 Surveys from only the last 10 years are used in order to ensure delivery of currently relevant information. The exception to this is areas off the Atlantic coast, where bird returns are based on all years of available data, since data in these areas is currently much more sparse. Migratory birds Measures for Proactively Minimizing Migratory Bird Impacts Your IPaC Migratory Bird list showcases birds of concern, including Birds of Conservation Concern (BCC), in your project location. This is not a comprehensive list of all birds found in your project area. However, you can help proactively minimize significant impacts to all birds at your project location by implementing the measures in the Nationwide avoidance and minimization measures for birds document, and any other project-specific avoidance and minimization measures suggested at the link Measures for avoiding and minimizing impacts to birds for the birds of concern on your list below. Ensure Your Migratory Bird List is Accurate and Complete If your project area is in a poorly surveyed area, your list may not be complete and you may need to rely on other resources to determine what species may be present (e.g. your local FWS field office, state surveys, your own surveys). Please review the Supplemental Information on Migratory Birds and Eagles document, to help you properly interpret the report for your specified location, including determining if there is sufficient data to ensure your list is accurate. For guidance on when to schedule activities or implement avoidance and minimization measures to reduce impacts to migratory birds on your list, see the "Probability of Presence Summary" below to see when these birds are most likely to be present and breeding in your project area. Review the FAQs The FAQs below provide important additional information and resources. BREEDING SEASON The Migratory Bird Treaty Act (MBTA) prohibits the take (including killing, capturing, selling, trading, and transport) of protected migratory bird species without prior authorization by the Department of Interior U.S. Fish and Wildlife Service (Service). 1. The Migratory Birds Treaty Act of 1918. 2. The Bald and Golden Eagle Protection Act of 1940. Additional information can be found using the following links: Eagle Management https://www.fws.gov/program/eagle-management Measures for avoiding and minimizing impacts to birds https://www.fws.gov/library/collections/avoiding-and-minimizing-incidental- take-migratory-birds Nationwide avoidance and minimization measures for birds Supplemental Information for Migratory Birds and Eagles in IPaC https://www.fws.gov/media/supplemental-information-migratory- birds-and-bald-and-golden-eagles-may-occur-project-action 1 NAME American Kestrel Falco sparverius paulus This is a Bird of Conservation Concern (BCC) only in particular Bird Conservation Regions (BCRs) in the continental USA https://ecos.fws.gov/ecp/species/9587 Breeds Apr 1 to Aug 31 American Oystercatcher Haematopus palliatus This is a Bird of Conservation Concern (BCC) throughout its range in the continental USA and Alaska. https://ecos.fws.gov/ecp/species/8935 Breeds Apr 15 to Aug 31 Bald Eagle Haliaeetus leucocephalus This is not a Bird of Conservation Concern (BCC) in this area, but warrants attention because of the Eagle Act or for potential susceptibilities in offshore areas from certain types of development or activities. Breeds Sep 1 to Jul 31 Chimney Swift Chaetura pelagica This is a Bird of Conservation Concern (BCC) throughout its range in the continental USA and Alaska. Breeds Mar 15 to Aug 25 Great Blue Heron Ardea herodias occidentalis This is a Bird of Conservation Concern (BCC) only in particular Bird Conservation Regions (BCRs) in the continental USA Breeds Jan 1 to Dec 31 3/22/26, 10:53 AM IPaC: Explore Location resources https://ipac.ecosphere.fws.gov/location/KDZIO6CFHFFH5LD5XG2D3KMFHY/resources 6/11Page 152 of 456 Probability of Presence Summary The graphs below provide our best understanding of when birds of concern are most likely to be present in your project area. This information can be used to tailor and schedule your project activities to avoid or minimize impacts to birds. Please make sure you read "Supplemental Information on Migratory Birds and Eagles", specifically the FAQ section titled "Proper Interpretation and Use of Your Migratory Bird Report" before using or attempting to interpret this report. Probability of Presence () Each green bar represents the bird's relative probability of presence in the 10km grid cell(s) your project overlaps during a particular week of the year. (A year is represented as 12 4-week months.) A taller bar indicates a higher probability of species presence. The survey effort (see below) can be used to establish a level of confidence in the presence score. One can have higher confidence in the presence score if the corresponding survey effort is also high. How is the probability of presence score calculated? The calculation is done in three steps: Least Tern Sternula antillarum antillarum This is a Bird of Conservation Concern (BCC) throughout its range in the continental USA and Alaska. Breeds Apr 25 to Sep 5 Lesser Yellowlegs Tringa flavipes This is a Bird of Conservation Concern (BCC) throughout its range in the continental USA and Alaska. https://ecos.fws.gov/ecp/species/9679 Breeds elsewhere Magnificent Frigatebird Fregata magnificens This is a Bird of Conservation Concern (BCC) only in particular Bird Conservation Regions (BCRs) in the continental USA Breeds Oct 1 to Apr 30 Painted Bunting Passerina ciris This is a Bird of Conservation Concern (BCC) only in particular Bird Conservation Regions (BCRs) in the continental USA Breeds Apr 25 to Aug 15 Pectoral Sandpiper Calidris melanotos This is a Bird of Conservation Concern (BCC) throughout its range in the continental USA and Alaska. Breeds elsewhere Prairie Warbler Setophaga discolor This is a Bird of Conservation Concern (BCC) throughout its range in the continental USA and Alaska. Breeds May 1 to Jul 31 Reddish Egret Egretta rufescens This is a Bird of Conservation Concern (BCC) throughout its range in the continental USA and Alaska. https://ecos.fws.gov/ecp/species/7617 Breeds Mar 1 to Sep 15 Ruddy Turnstone Arenaria interpres morinella This is a Bird of Conservation Concern (BCC) only in particular Bird Conservation Regions (BCRs) in the continental USA Breeds elsewhere Semipalmated Sandpiper Calidris pusilla This is a Bird of Conservation Concern (BCC) only in particular Bird Conservation Regions (BCRs) in the continental USA Breeds elsewhere Short-billed Dowitcher Limnodromus griseus This is a Bird of Conservation Concern (BCC) throughout its range in the continental USA and Alaska. https://ecos.fws.gov/ecp/species/9480 Breeds elsewhere Swallow-tailed Kite Elanoides forficatus This is a Bird of Conservation Concern (BCC) throughout its range in the continental USA and Alaska. https://ecos.fws.gov/ecp/species/8938 Breeds Mar 10 to Jun 30 Worthington's Marsh Wren Cistothorus palustris griseus This is a Bird of Conservation Concern (BCC) only in particular Bird Conservation Regions (BCRs) in the continental USA Breeds Apr 10 to Aug 31 3/22/26, 10:53 AM IPaC: Explore Location resources https://ipac.ecosphere.fws.gov/location/KDZIO6CFHFFH5LD5XG2D3KMFHY/resources 7/11Page 153 of 456 no data survey effort breeding season probability of presence 1. The probability of presence for each week is calculated as the number of survey events in the week where the species was detected divided by the total number of survey events for that week. For example, if in week 12 there were 20 survey events and the Spotted Towhee was found in 5 of them, the probability of presence of the Spotted Towhee in week 12 is 0.25. 2. To properly present the pattern of presence across the year, the relative probability of presence is calculated. This is the probability of presence divided by the maximum probability of presence across all weeks. For example, imagine the probability of presence in week 20 for the Spotted Towhee is 0.05, and that the probability of presence at week 12 (0.25) is the maximum of any week of the year. The relative probability of presence on week 12 is 0.25/0.25 = 1; at week 20 it is 0.05/0.25 = 0.2. 3. The relative probability of presence calculated in the previous step undergoes a statistical conversion so that all possible values fall between 0 and 10, inclusive. This is the probability of presence score. To see a bar's probability of presence score, simply hover your mouse cursor over the bar. Breeding Season () Yellow bars denote a very liberal estimate of the time-frame inside which the bird breeds across its entire range. If there are no yellow bars shown for a bird, it does not breed in your project area. Survey Effort () Vertical black lines superimposed on probability of presence bars indicate the number of surveys performed for that species in the 10km grid cell(s) your project area overlaps. The number of surveys is expressed as a range, for example, 33 to 64 surveys. To see a bar's survey effort range, simply hover your mouse cursor over the bar. No Data () A week is marked as having no data if there were no survey events for that week. Survey Timeframe Surveys from only the last 10 years are used in order to ensure delivery of currently relevant information. The exception to this is areas off the Atlantic coast, where bird returns are based on all years of available data, since data in these areas is currently much more sparse. SPECIES JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC American Kestrel BCC - BCR American Oystercatcher BCC Rangewide (CON) Bald Eagle Non-BCC Vulnerable Chimney Swift BCC Rangewide (CON) Great Blue Heron BCC - BCR Least Tern BCC Rangewide (CON) Lesser Yellowlegs BCC Rangewide (CON) Magnificent Frigatebird BCC - BCR Painted Bunting BCC - BCR Pectoral Sandpiper BCC Rangewide (CON) Prairie Warbler BCC Rangewide (CON) Reddish Egret BCC Rangewide (CON) SPECIES JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC Ruddy Turnstone BCC - BCR Semipalmated Sandpiper BCC - BCR Short-billed Dowitcher BCC Rangewide (CON) Swallow-tailed Kite BCC Rangewide (CON) Worthington's Marsh Wren BCC - BCR 3/22/26, 10:53 AM IPaC: Explore Location resources https://ipac.ecosphere.fws.gov/location/KDZIO6CFHFFH5LD5XG2D3KMFHY/resources 8/11Page 154 of 456 Migratory Bird FAQs Tell me more about avoidance and minimization measures I can implement to avoid or minimize impacts to migratory birds. Nationwide Avoidance & Minimization Measures for Birds describes measures that can help avoid and minimize impacts to all birds at any location year- round. When birds may be breeding in the area, identifying the locations of any active nests and avoiding their destruction is one of the most effective ways to minimize impacts. To see when birds are most likely to occur and breed in your project area, view the Probability of Presence Summary. Additional measures or permits may be advisable depending on the type of activity you are conducting and the type of infrastructure or bird species present on your project site. What does IPaC use to generate the list of migratory birds that potentially occur in my specified location? The Migratory Bird Resource List is comprised of Birds of Conservation Concern (BCC) and other species that may warrant special attention in your project location, such as those listed under the Endangered Species Act or the Bald and Golden Eagle Protection Act and those species marked as “Vulnerable”. See the FAQ “What are the levels of concern for migratory birds?” for more information on the levels of concern covered in the IPaC migratory bird species list. The migratory bird list generated for your project is derived from data provided by the Avian Knowledge Network (AKN). The AKN data is based on a growing collection of survey, banding, and citizen science datasets and is queried and filtered to return a list of those birds reported as occurring in the 10km grid cell(s) with which your project intersects. These species have been identified as warranting special attention because they are BCC species in that area, an eagle (Bald and Golden Eagle Protection Act requirements may apply), or a species that has a particular vulnerability to offshore activities or development. Again, the Migratory Bird Resource list includes only a subset of birds that may occur in your project area. It is not representative of all birds that may occur in your project area. To get a list of all birds potentially present in your project area, and to verify survey effort when no results present, please visit the Rapid Avian Information Locator (RAIL) Tool. Why are subspecies showing up on my list? Subspecies profiles are included on the list of species present in your project area because observations in the AKN for the species are being detected. If the species are present, that means that the subspecies may also be present. If a subspecies shows up on your list, you may need to rely on other resources to determine if that subspecies may be present (e.g. your local FWS field office, state surveys, your own surveys). What does IPaC use to generate the probability of presence graphs for the migratory birds potentially occurring in my specified location? The probability of presence graphs associated with your migratory bird list are based on data provided by the Avian Knowledge Network (AKN). This data is derived from a growing collection of survey, banding, and citizen science datasets. Probability of presence data is continuously being updated as new and better information becomes available. To learn more about how the probability of presence graphs are produced and how to interpret them, go to the Probability of Presence Summary and then click on the "Tell me about these graphs" link. How do I know if a bird is breeding, wintering, or migrating in my area? To see what part of a particular bird's range your project area falls within (i.e. breeding, wintering, migrating, or resident), you may query your location using the RAIL Tool and view the range maps provided for birds in your area at the bottom of the profiles provided for each bird in your results. If a bird on your IPaC migratory bird species list has a breeding season associated with it (indicated by yellow vertical bars on the phenology graph in your “IPaC PROBABILITY OF PRESENCE SUMMARY” at the top of your results list), there may be nests present at some point within the timeframe specified. If "Breeds elsewhere" is indicated, then the bird likely does not breed in your project area. What are the levels of concern for migratory birds? Migratory birds delivered through IPaC fall into the following distinct categories of concern: 1. "BCC Rangewide" birds are Birds of Conservation Concern (BCC) that are of concern throughout their range anywhere within the USA (including Hawaii, the Pacific Islands, Puerto Rico, and the Virgin Islands); 2. "BCC - BCR" birds are BCCs that are of concern only in particular Bird Conservation Regions (BCRs) in the continental USA; and 3. "Non-BCC - Vulnerable" birds are not BCC species in your project area, but appear on your list either because of the Bald and Golden Eagle Protection Act requirements (for eagles) or (for non-eagles) potential susceptibilities in offshore areas from certain types of development or activities (e.g. offshore energy development or longline fishing). Although it is important to avoid and minimize impacts to all birds, efforts should be made, in particular, to avoid and minimize impacts to the birds on this list, especially BCC species. For more information on avoidance and minimization measures you can implement to help avoid and minimize migratory bird impacts, please see the FAQ “Tell me more about avoidance and minimization measures I can implement to avoid or minimize impacts to migratory birds”. Details about birds that are potentially affected by offshore projects For additional details about the relative occurrence and abundance of both individual bird species and groups of bird species within your project area off the Atlantic Coast, please visit the Northeast Ocean Data Portal. The Portal also offers data and information about other taxa besides birds that may be helpful to you in your project review. Alternately, you may download the bird model results files underlying the portal maps through the NOAA NCCOS Integrative Statistical Modeling and Predictive Mapping of Marine Bird Distributions and Abundance on the Atlantic Outer Continental Shelf project webpage. Proper interpretation and use of your migratory bird report The migratory bird list generated is not a list of all birds in your project area, only a subset of birds of priority concern. To learn more about how your list is generated and see options for identifying what other birds may be in your project area, please see the FAQ "What does IPaC use to generate the migratory birds potentially occurring in my specified location". Please be aware this report provides the "probability of presence" of birds within the 10 km grid cell(s) that overlap your project; not your exact project footprint. On the graphs provided, please look carefully at the survey effort (indicated by the black vertical line) and for the existence of the "no data" indicator (a red horizontal line). A high survey effort is the key component. If the survey effort is high, then the 3/22/26, 10:53 AM IPaC: Explore Location resources https://ipac.ecosphere.fws.gov/location/KDZIO6CFHFFH5LD5XG2D3KMFHY/resources 9/11Page 155 of 456 probability of presence score can be viewed as more dependable. In contrast, a low survey effort bar or no data bar means a lack of data and, therefore, a lack of certainty about presence of the species. This list does not represent all birds present in your project area. It is simply a starting point for identifying what birds of concern have the potential to be in your project area, when they might be there, and if they might be breeding (which means nests might be present). The list and associated information help you know what to look for to confirm presence and helps guide implementation of avoidance and minimization measures to eliminate or reduce potential impacts from your project activities, should presence be confirmed. To learn more about avoidance and minimization measures, visit the FAQ "Tell me about avoidance and minimization measures I can implement to avoid or minimize impacts to migratory birds". Interpreting the Probability of Presence Graphs Each green bar represents the bird's relative probability of presence in the 10km grid cell(s) your project overlaps during a particular week of the year. A taller bar indicates a higher probability of species presence. The survey effort can be used to establish a level of confidence in the presence score. How is the probability of presence score calculated? The calculation is done in three steps: The probability of presence for each week is calculated as the number of survey events in the week where the species was detected divided by the total number of survey events for that week. For example, if in week 12 there were 20 survey events and the Spotted Towhee was found in 5 of them, the probability of presence of the Spotted Towhee in week 12 is 0.25. To properly present the pattern of presence across the year, the relative probability of presence is calculated. This is the probability of presence divided by the maximum probability of presence across all weeks. For example, imagine the probability of presence in week 20 for the Spotted Towhee is 0.05, and that the probability of presence at week 12 (0.25) is the maximum of any week of the year. The relative probability of presence on week 12 is 0.25/0.25 = 1; at week 20 it is 0.05/0.25 = 0.2. The relative probability of presence calculated in the previous step undergoes a statistical conversion so that all possible values fall between 0 and 10, inclusive. This is the probability of presence score. Breeding Season () Yellow bars denote a very liberal estimate of the time-frame inside which the bird breeds across its entire range. If there are no yellow bars shown for a bird, it does not breed in your project area. Survey Effort () Vertical black lines superimposed on probability of presence bars indicate the number of surveys performed for that species in the 10km grid cell(s) your project area overlaps. No Data () A week is marked as having no data if there were no survey events for that week. Survey Timeframe Surveys from only the last 10 years are used in order to ensure delivery of currently relevant information. The exception to this is areas off the Atlantic coast, where bird returns are based on all years of available data, since data in these areas is currently much more sparse. Facilities National Wildlife Refuge lands Any activity proposed on lands managed by the National Wildlife Refuge system must undergo a 'Compatibility Determination' conducted by the Refuge. Please contact the individual Refuges to discuss any questions or concerns. There are no refuge lands at this location. Fish hatcheries There are no fish hatcheries at this location. Wetlands in the National Wetlands Inventory (NWI) Impacts to NWI wetlands and other aquatic habitats may be subject to regulation under Section 404 of the Clean Water Act, or other State/Federal statutes. For more information please contact the Regulatory Program of the local U.S. Army Corps of Engineers District. Please note that the NWI data being shown may be out of date. We are currently working to update our NWI data set. We recommend you verify these results with a site visit to determine the actual extent of wetlands on site. This location overlaps the following wetlands: RIVERINE R2UBHx R5UBFx 3/22/26, 10:53 AM IPaC: Explore Location resources https://ipac.ecosphere.fws.gov/location/KDZIO6CFHFFH5LD5XG2D3KMFHY/resources 10/11Page 156 of 456 NOTE: This initial screening does not replace an on-site delineation to determine whether wetlands occur. Additional information on the NWI data is provided below. Data limitations The Service's objective of mapping wetlands and deepwater habitats is to produce reconnaissance level information on the location, type and size of these resources. The maps are prepared from the analysis of high altitude imagery. Wetlands are identified based on vegetation, visible hydrology and geography. A margin of error is inherent in the use of imagery; thus, detailed on-the-ground inspection of any particular site may result in revision of the wetland boundaries or classification established through image analysis. The accuracy of image interpretation depends on the quality of the imagery, the experience of the image analysts, the amount and quality of the collateral data and the amount of ground truth verification work conducted. Metadata should be consulted to determine the date of the source imagery used and any mapping problems. Wetlands or other mapped features may have changed since the date of the imagery or field work. There may be occasional differences in polygon boundaries or classifications between the information depicted on the map and the actual conditions on site. Data exclusions Certain wetland habitats are excluded from the National mapping program because of the limitations of aerial imagery as the primary data source used to detect wetlands. These habitats include seagrasses or submerged aquatic vegetation that are found in the intertidal and subtidal zones of estuaries and nearshore coastal waters. Some deepwater reef communities (coral or tuberficid worm reefs) have also been excluded from the inventory. These habitats, because of their depth, go undetected by aerial imagery. Data precautions Federal, state, and local regulatory agencies with jurisdiction over wetlands may define and describe wetlands in a different manner than that used in this inventory. There is no attempt, in either the design or products of this inventory, to define the limits of proprietary jurisdiction of any Federal, state, or local government or to establish the geographical scope of the regulatory programs of government agencies. Persons intending to engage in activities involving modifications within or adjacent to wetland areas should seek the advice of appropriate Federal, state, or local agencies concerning specified agency regulatory programs and proprietary jurisdictions that may affect such activities. A full description for each wetland code can be found at the National Wetlands Inventory website 3/22/26, 10:53 AM IPaC: Explore Location resources https://ipac.ecosphere.fws.gov/location/KDZIO6CFHFFH5LD5XG2D3KMFHY/resources 11/11Page 157 of 456 Appendix C Wetlands & OSW Boundary Survey Page 158 of 456 icrosoft Corporation © 2025 Maxar ©CNES (2025) Distribution Airbus DS © 2025 TMAP MOBILITY Eart h s t a r G e o g r a p h i c s S I O E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E-TOB E-TOB E-TOB E-TOB E - T O B E - T O B E-TOB E-TOB E-TOB E-TOB E-TOB E-TOE E-TOE E-TOE E-TOE E-TOE E-TOE E-TOE E-TOE E-TOE E - T O E E-TOB E-TOB E-TOB E-TOB E - T O B E-TOE E-TOE E-TOE E-TOE E - T O E E-TOB E-TOB E-TOB E-TOB E-TOE E-TOE E-TOE E-TOE E-TOB E-TOB E-TOB E-TOB E-TOE E-TOE E-TOE E-TOE O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O B N0 ° 3 5 ' 0 6 . 7 4 " E 80 . 9 3 5 N0 ° 3 5 ' 0 6 . 7 4 " E 18 0 8 . 2 0 1 S89° 54' 38.11"E 1292.839 N0 ° 3 7 ' 2 9 . 7 8 " E 17 0 . 0 0 7 S89° 54' 38.11"E 1052.235 S0 ° 3 9 ' 5 3 . 2 6 " W 20 8 . 7 2 1 S89° 54' 38.11"E 208.721 S0 ° 3 9 ' 5 3 . 2 6 " W 17 6 3 . 5 8 9 S89° 57' 23.02"W 589.804 S0 ° 3 8 ' 4 1 . 4 6 " W 23 0 . 0 1 7 N89° 57' 23.02"E 581.413 S0 ° 1 4 ' 4 3 . 3 1 " W 27 3 . 1 7 3 S89° 58' 37.21"W 1251.214 N0 ° 2 5 ' 3 8 . 5 8 " E 30 1 . 7 3 0 S89° 57' 23.02"W 1292.257 N0 ° 3 6 ' 3 5 . 0 8 " E 20 1 . 0 1 3 L=1419.787,R=1608.000 D=50.5894 L=1379.595,R=1528.000 D=51.7310 N89° 57' 23.02"E 58.448 L=1348.435,R=1528.000 D=50.5626 L=1451.825, R=1608.000 D=51.7310 N89° 57' 23.02"E 60.006 E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O B E - T O B TYPICAL TOWNHOUSE LOT LAYOUTSCALE: 1"=40' WETLAND NO. 1 WE T L A N D N O . 2 icrosoft Corporation © 2025 Maxar ©CNES (2025) Distribution Airbus DS © 2025 TMAP MOBILITY Earthstar Geographics SIO WETLAND NO. 1 WETL A N D N O . 2 VICINITY MAP SCALE: 1:1,000 VERTICAL DATUM NOTE: ELEVATIONS SHOWN HEREON ARE RELATIVE TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (N.A.V.D.88) AND ARE GIVEN IN U.S. SURVEY FEET UNLESS OTHERWISE NOTED. *GENERAL ACCEPTED CONVERSION: NAVD + 1.475 = NGVD NOTE: THE PROPERTY OWNER, CONTRACTOR, AND AUTHORIZED REPRESENTATIVES SHALL PROVIDE PICKUP, REMOVAL, AND DISPOSAL OF LITTER WITHIN THE PROJECT LIMITS AND SHALL BE RESPONSIBLE FOR MAINTENANCE OF THE AREA FROM THE EDGE OF PAVEMENT TO THE PROPERTY LINE WITHIN THE RIGHT-OF-WAY SITE ( IN FEET ) GRAPHIC SCALE 0150 75 150 300 450 1 inch = 150 ft. 10250 Village Parkway, Suite 201 Port Saint Lucie, Florida 34987 772.462.2455930 S. Harbor City Blvd, Suite 506Melbourne, FL 32901321.280.9969 1234567 PROJECT TITLE DATE SCALE DRAWN BY DESIGNED BY CHECKED BY PROJECT No. DRAWING No.REV. A B C D A B C D FIL E L O C A T I O N : Z: \ E D C - 2 0 2 5 \ 2 5 - 1 1 3 - I N D R I O C R E E K - S E M I N O L E R O A D - 1 2 7 - A C R E S \ E N G I N E E R I N G \ A U T O C A D \ D W G S \ 2 5 - 1 1 3 R 2 5 . D W G , 20 2 6 . 0 3 . 1 9 , 2: 0 2 P M CERTIFICATE OF AUTHORIZATION No. 1234567 HALEY WARD ENGINEERING ENVIRONMENTAL SURVEYING WWW.HALEYWARD.COM LAND PLANNING INTERIOR DESIGN WETLAND IMPACT PLAN 3/19/2026 AS SHOWN JJL JJL MDL 25-113 R25.DWG WETLAND C.O.A. No. DESCRIPTION BY CHK.DATE DRAWING ISSUE STATUS REV. Know what's below. Call before you dig. www.callsunshine.com It's fast. It's free. It's the law. 10250 SW VILLAGE PARKWAY - SUITE 201 PORT SAINT LUCIE, FL 34987 ' 772-462-2455 (DATE) THE CLUB AT INDRIO CREEK ST. LUCIE COUNTY, FLORIDA VICINITY MAP SCALE: 1:1,000 SE M I N O L E R O A D EM E R S O N A V E F. P . F . W . C . D . C A N A L N O . 5 F. P . F . W . C . D . C A N A L N O . 6 EM E R S O N A V E N U E SE M I N O L E R O A D LEGEND WETLAND BUFFERS WETLANDS - 2.05 AC. DIRECT WETLAND IMPACTS - 2.05 AC. SITE BOUNDARY - 127.03 AC. Page 159 of 456 Attachment 2 Wetland & OSW Boundary Survey Page 160 of 456 icrosoft Corporation © 2025 Maxar ©CNES (2025) Distribution Airbus DS © 2025 TMAP MOBILITY Eart h s t a r G e o g r a p h i c s S I O E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E-TOB E-TOB E-TOB E-TOB E - T O B E - T O B E-TOB E-TOB E-TOB E-TOB E-TOB E-TOE E-TOE E-TOE E-TOE E-TOE E-TOE E-TOE E-TOE E-TOE E - T O E E-TOB E-TOB E-TOB E-TOB E - T O B E-TOE E-TOE E-TOE E-TOE E - T O E E-TOB E-TOB E-TOB E-TOB E-TOE E-TOE E-TOE E-TOE E-TOB E-TOB E-TOB E-TOB E-TOE E-TOE E-TOE E-TOE O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O B E - T O B E - T O B E - T O B E - T O B E - T O B E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O B N0 ° 3 5 ' 0 6 . 7 4 " E 80 . 9 3 5 N0 ° 3 5 ' 0 6 . 7 4 " E 18 0 8 . 2 0 1 S89° 54' 38.11"E 1292.839 N0 ° 3 7 ' 2 9 . 7 8 " E 17 0 . 0 0 7 S89° 54' 38.11"E 1052.235 S0 ° 3 9 ' 5 3 . 2 6 " W 20 8 . 7 2 1 S89° 54' 38.11"E 208.721 S0 ° 3 9 ' 5 3 . 2 6 " W 17 6 3 . 5 8 9 S89° 57' 23.02"W 589.804 S0 ° 3 8 ' 4 1 . 4 6 " W 23 0 . 0 1 7 N89° 57' 23.02"E 581.413 S0 ° 1 4 ' 4 3 . 3 1 " W 27 3 . 1 7 3 S89° 58' 37.21"W 1251.214 N0 ° 2 5 ' 3 8 . 5 8 " E 30 1 . 7 3 0 S89° 57' 23.02"W 1292.257 N0 ° 3 6 ' 3 5 . 0 8 " E 20 1 . 0 1 3 L=1419.787,R=1608.000 D=50.5894 L=1379.595,R=1528.000 D=51.7310 N89° 57' 23.02"E 58.448 L=1348.435,R=1528.000 D=50.5626 L=1451.825, R=1608.000 D=51.7310 N89° 57' 23.02"E 60.006 E - T O E E - T O E E - T O E E - T O E E - T O E E - T O E E - T O B E - T O B TYPICAL TOWNHOUSE LOT LAYOUTSCALE: 1"=40' WETLAND NO. 1 WE T L A N D N O . 2 icrosoft Corporation © 2025 Maxar ©CNES (2025) Distribution Airbus DS © 2025 TMAP MOBILITY Earthstar Geographics SIO WETLAND NO. 1 WETL A N D N O . 2 VICINITY MAP SCALE: 1:1,000 VERTICAL DATUM NOTE: ELEVATIONS SHOWN HEREON ARE RELATIVE TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (N.A.V.D.88) AND ARE GIVEN IN U.S. SURVEY FEET UNLESS OTHERWISE NOTED. *GENERAL ACCEPTED CONVERSION: NAVD + 1.475 = NGVD NOTE: THE PROPERTY OWNER, CONTRACTOR, AND AUTHORIZED REPRESENTATIVES SHALL PROVIDE PICKUP, REMOVAL, AND DISPOSAL OF LITTER WITHIN THE PROJECT LIMITS AND SHALL BE RESPONSIBLE FOR MAINTENANCE OF THE AREA FROM THE EDGE OF PAVEMENT TO THE PROPERTY LINE WITHIN THE RIGHT-OF-WAY SITE ( IN FEET ) GRAPHIC SCALE 0150 75 150 300 450 1 inch = 150 ft. 10250 Village Parkway, Suite 201 Port Saint Lucie, Florida 34987 772.462.2455930 S. Harbor City Blvd, Suite 506Melbourne, FL 32901321.280.9969 1234567 PROJECT TITLE DATE SCALE DRAWN BY DESIGNED BY CHECKED BY PROJECT No. DRAWING No.REV. A B C D A B C D FIL E L O C A T I O N : Z: \ E D C - 2 0 2 5 \ 2 5 - 1 1 3 - I N D R I O C R E E K - S E M I N O L E R O A D - 1 2 7 - A C R E S \ E N G I N E E R I N G \ A U T O C A D \ D W G S \ 2 5 - 1 1 3 R 2 5 . D W G , 20 2 6 . 0 3 . 1 9 , 2: 0 2 P M CERTIFICATE OF AUTHORIZATION No. 1234567 HALEY WARD ENGINEERING ENVIRONMENTAL SURVEYING WWW.HALEYWARD.COM LAND PLANNING INTERIOR DESIGN WETLAND IMPACT PLAN 3/19/2026 AS SHOWN JJL JJL MDL 25-113 R25.DWG WETLAND C.O.A. No. DESCRIPTION BY CHK.DATE DRAWING ISSUE STATUS REV. Know what's below. Call before you dig. www.callsunshine.com It's fast. It's free. It's the law. 10250 SW VILLAGE PARKWAY - SUITE 201 PORT SAINT LUCIE, FL 34987 ' 772-462-2455 (DATE) THE CLUB AT INDRIO CREEK ST. LUCIE COUNTY, FLORIDA VICINITY MAP SCALE: 1:1,000 SE M I N O L E R O A D EM E R S O N A V E F. P . F . W . C . D . C A N A L N O . 5 F. P . F . W . C . D . C A N A L N O . 6 EM E R S O N A V E N U E SE M I N O L E R O A D LEGEND WETLAND BUFFERS WETLANDS - 2.05 AC. DIRECT WETLAND IMPACTS - 2.05 AC. SITE BOUNDARY - 127.03 AC. Page 161 of 456 Attachment 3 Uniformed Mitigation Assessment Methodology (UMAM) Page 162 of 456 Site/Project Name:Application Number:Assessment Area Name or Number: Impact or Mitigation Site?Assessment Area Size: Assessment conducted by:Assessment date(s): Form 62-345.900(1), F.A.C. [ effective date 02-04-2004 ] Observed Evidence of Wildlife Utilization (List species directly observed, or other signs such as tracks, droppings, casings, nests, etc.): Dense vegetative cover in many areas. Overall wildlife usage also is low, with water depths not appropriate for the support of wading birds. Furthermore, this system has no connection of offsite wildlife corridors or upland habitats of significance. Additional relevant factors: Non Applicable April S. Ostrom, Professional Wetland Scientist (2885)/Jennifer Acevedo 2/12/2026 nutrient sink Anticipated Wildlife Utilization Based on Literature Review (List of species that are representative of the assessment area and reasonably expected to be found ): Anticipated Utilization by Listed Species (List species, their legal classification (E, T, SSC), type of use, and intensity of use of the assessment area): Small mammals and amphibians. Possible wading birds Hydrology and community structure is not sufficient to support listed wading birds nesting This wetland is interior to a historical tree farm with row and furrow topography. Tree farm was abandoned and land transitioned to cattle however no grading changes were made in this area. Artesian wells were opened at a high velocity flooding the assessment area, eroding furrows. Wetland plants recruited naturally due to hydrological input. Dominated by exotic vegetation with species associated with poor water quality. Significant nearby features: Uniqueness (considering the relative rarity in relation to the regional landscape): No significant nearby features.Onsite wetland is predominantly exotic species, habitat type is not unique to the region. Functions:Mitigation for previous permit/other historic use: WBID: 3194A, North St. Lucie (HUC 3090202)Tenmile Creek N/A Geographic relationship to and hydrologic connection with wetlands, other surface water, uplands: Isolated wetland with no offsite connections. Located inside an abandoned tree farm. Surrounding upland disturbed farm lands in which management has ceased. System has been artificially hydrated via two artesian wells. Wells recently capped and hydrology stabilized. Assessment area description: 619 FLUCCS/74 CLC: Exotic Wetland Impact 1.88 Basin/Watershed Name/Number:Affected Waterbody (Class):Special Classification (i.e.OFW, AP, other local/state/federal designati PART I – Qualitative Description (See Section 62-345.400, F.A.C.) Club at Indrio Creek Wetland FLUCCs code:Further classification (optional): Page 163 of 456 w/o pres or current w/o pres or current w/o pres or current currentor w/o pres Form 62-345.900(2), F.A.C. [effective date 02-04-2004] If mitigation For mitigation assessment areas Delta = [with-current]Time lag (t-factor) = N/A RFG = delta/(t-factor x risk) = N/A0.4 Risk factor = N/A Score = sum of above scores/30 (if uplands, divide by 20)If preservation as mitigation, For impact assessment areas Preservation adjustment factor = N/A FL = delta x acres = 0.40 X 1.88 = 0.75withAdjusted mitigation delta = N/A0.4 0 .500(6)(c)Community structure Community structure of Wetland 1 is almost solely (±90%) exotic invasive species as well as species commonly associated with poor water quality such as torpedo grass, para grass, water lettuce, cattails, and Brazilian pepper. Minimal recruitment of native vegetation was noted; water quality is poor receiving agricultural runoff with plants indicative of a high nutrient environment and light penetration is limited. Topography within this system is also severely altered with notable areas of degraded farm furrows, which have further contributed to its ability to hold water. 1. Vegetation and/or 2. Benthic Community with 2 0 .500(6)(a) Location and Landscape Support :ocated in a rural area that is predominantly agricultural with a fringe of residential development and roadway to the north. The current and historical agricultural use of the subject property has resulted in impacts to the wetlands’ hydrology and community structure via factors such as degradation of water quality, topographic alterations from use in row crops and lack of management. Wildlife support has been negatively affected due to onsite conditions that include poor management and physical impediments but would maintain general “rural area” connectivity. Impedances to wildlife access would specifically be from factors such as Indrio Rd to the north, perimeter ditching, fencing and a heavy density of exotic vegetation onsite resulting in a closed canopy with limited access both on the ground and aerially for birds. Offsite wildlife corridors are partially disturbed due to aformentioned factors but also remain available due to the general rural nature of lands within 2 miles of the subject property. Conditions less than optimal, but should be considered moderate with some additional loss based on plant community composition in the proximity of the assessment area. with 6 0 .500(6)(b)Water Environment (n/a for uplands) Wetland 1 appears to have been artificially hydrated via an artesian well which has now ceased running, resulting in further hydrological alterations. These factors have resulted in less than optimal hydrology and community structure. In January 2025 wells observed to be open and actively discharging a high volume of water. One (1) well was noted at the far north end of Wetland 1, acting as a headwater for this system, consistently discharging a large volume of water noted to be flowing south. A second well near the center of the Wetland also adding large quantities of water into the system. Both wells capped with no further discharge as of the August 1, 2025. Water was observed to have receded south with dry areas in the vicinity of the original “headwater” well. Soils continued to transition, becoming more sandy and losing their dark mucky surface in concert with loss of wetland plants such as cattails. As of February 2026, the wetland has further receded and appears to have hydrologically stabilized, with standing water and wetland vegetation remaining in the southern end. Receiving agricultural run off, majority plants indicative of poor water quality. with 4 0 Scoring Guidance Optimal (10)Moderate(7)Minimal (4)Not Present (0) The scoring of each indicator is based on what would be suitable for the type of wetland or surface water assessed Condition is optimal and fully supports wetland/surface water functions Condition is less than optimal, but sufficient to maintain most wetland/surface water functions Minimal level of support of wetland/surface water functions Condition is insufficient to provide wetland/surface water functions Impact or Mitigation Assessment conducted by:Assessment date: Impact (1.88)A.S. Ostrom (PWS 2885)/J Acevedo 2/12/2026 PART II – Quantification of Assessment Area (impact or mitigation) (See Sections 62-345.500 and .600, F.A.C.) Site/Project Name Application Number Assessment Area Name or Number Club at Indrio Creek Wetland Page 164 of 456 Environmental resources final report TO: Irene Szedlmayer, Planning & Development Services Department THROUGH: Aimee L. Cooper, Environmental Regulations Manager Amy E. Griffin, Environmental Resources Director FROM: Brian Ingram, Senior Environmental Planner DATE: July 6th, 2026 SUBJECT: The Club at Indrio Creek – Preliminary Planned Development PD-2510-000058 Background The Environmental Resources Department (ERD) is in receipt of the June 30th, 2026, date-stamped submittal, transmitted on June 30th, 2026, from Planning and Development Services with comments due July 6th, 2026. The applicant is seeking approval of a preliminary Planned Development (PD) plan to rezone the six (6) subject parcels (PIDs 1314-323-0002-000-3, 1314-313-0000-000-8, 1314-331-0001-000-1, 1314-342-0001-000-5, 1314-341- 0000-000-5, 1323-211-0005-000-8) totaling ±127.09 acres from Agricultural, 1 du/ac (AG-1) to Planned Town or Village (PTV) within the Towns, Villages & Countryside (TVC) future land use designation and to allow for the development of three hundred seventy two (372) single and multi-family residential units. Additional features of the project include a clubhouse/amenity center, outdoor civic park spaces, a flow way traversing the project from northeast to southwest, greenways for pedestrian connectivity, landscaping, and associated site infrastructure. The project is located at 4575 Seminole Rd in Ft Pierce, approximately one quarter (1/4) mile south of the intersection of Indrio Rd and Seminole Rd. It is bound to the north by single family residential properties, to the south by agricultural land, to the east by a Ft Pierce Farms Water Control District (FPFWCD) drainage ditch with Seminole Rd and agricultural land beyond, and to the west by Emerson Ave and a FPFWCD ditch with agricultural land beyond. Findings An Environmental Impact Report, prepared by Aquatic Research and Monitoring, Equipment, and Deployment, LLC, and dated March 2026, was provided with the Preliminary Development Plan. The majority of the project site is an inactive tree farm that is currently being utilized for cattle grazing. No native upland habitat was identified onsite. Two (2) state jurisdictional wetlands have been delineated by Aquatic Research FL and have been verified by South Florida Water Management District (SFWMD) Application Number 260106-60453. Both wetlands are of low quality and are classified as Category III according to St Lucie County Comprehensive Plan Policy 6.1.14.1. as they are less than 5 acres and not connected to other surface water bodies or wetlands. Wetland 1 was classified as an exotic vegetation wetland measuring ±1.88 acres and is the result of two (2) flowing, high velocity, artisan wells. Both wells have now been capped, and the standing water has receded significantly to the south. Soils continue to transition, becoming more sandy and losing their dark mucky surface in concert with the disappearance of vegetation indicative of wetlands. Wetland 1 has an estimated UMAM score of 0.4. Mitigation for impacts, if applicable, will be required by SFWMD. Wetland 2 was classified as a freshwater marsh measuring ±0.17 acres. Community structure for Wetland 2 includes both native and exotic species. As wetland 2 measures less the 0.5 acres, no mitigation for impacts will be required by SFWMD. The initial submittal and 1st resubmittal of the Preliminary Regulating Plan included 100% impacts to both wetlands and all of their associated buffer. A Category III Wetland Waiver (WTLW-2604-000055) was administratively approved May 21st, 2026, by the Environmental Resources Department Director, which authorized impacts to 100% of both wetlands and their Page 165 of 456 buffers. In an effort to gain increased density for the project via the preservation and/or restoration of native habitat, the 2nd resubmittal included a shifting of the flow way system out of the Wetland 1 area, in which case it may be preserved. To gain a density increase within the Planned Town and Village (PTV) zoning district, applicants may restore areas, to measure not less than 25 acres, into native upland and wetland habitat in accordance with LDC 3.01.03.EE.2.o.5. The areas shall be connected to the greatest extent possible to the flow way system or other preserved native or environmentally sensitive habitat. The area must include only native species of canopy, understory, and ground cover, and must include multiple upland and wetland habitat types. Deep water habitats and their required upland buffer areas and littoral zones are not eligible for the density bonus. Restored habitats must include a restoration plan that identifies the area to be restored, a strategy employed to restore the land, a timetable for restoration, measures to evaluate the success of the restoration, and a funding strategy for monitoring and maintaining the habitat. Thin strips of “restored habitat” area are proposed between residential blocks, property lines, parking lots, and stormwater areas. These areas do not, “to the greatest extent possible”, connect with the flow way or other preserved native habitat or environmentally sensitive areas. The submitted plans do not differentiate between, and appear to include, the required upland transition zone for the flow way system, which is specifically prohibited by the density bonus restoration area code. The area proposed for the density bonus does not appear to meet the minimum requirements and intent of the Land Development Code. The required flow way system within the TVC future land use and PTV zoning district shall include all land and water areas that together comprise the contiguous water management system per LDC 4.04.06. The flow way system shall provide twenty (20) square ft. of upland transition zone and twenty (20) square ft. of littoral area in accordance with LDC 3.01.03.EE.2.p. The supplied plans do not specifically identify the upland transition zone area required by LDC 3.01.03.EE.2.p.4.iii. and do not meet the minimum littoral zone requirements of LDC 3.01.03.EE.2.p.4.ii.3. A preliminary tree survey and mitigation plan was submitted and reviewed. The plan identified a total of forty-six (46) native canopy trees and seventy-seven (77) palms meeting the mitigation thresholds identified in LDC 6.00.05. A finalized tree mitigation plan will be required at the time of final site plan approval. Recommendation The proposed restoration area does not appear to meet the minimum requirements and intent of the LDC. The plan does not sufficiently identify and differentiate between the upland transition zone required for the flow way and the habitat restoration area needed for the density bonus. It also fails to meet the intent of the Land Development Code regarding the necessity that the habitat restoration area “to the greatest extent possible” connect with the flow way system or other preserved native habitat or environmentally sensitive areas. The plan does not provide sufficient littoral zone area to meet the minimum requirements of the flow way system within the TVC and PTV. ERD recommends that the items identified as outstanding corrections be addressed prior to approval. Conditions of Approval Subject to resolution of the findings listed above, the following is a partial list of conditions of approval: 1) Prior to Site Plan approval, a finalized landscape plan consistent with LDC 7.09.00 and LDC 3.01.03.EE. shall be provided to and approved by ERD. 2) Prior to Site Plan approval, a finalized tree mitigation plan consistent with LDC 6.00.05 shall be provided to and approved by ERD. 3) Prior to commencement of development, including, but not limited to clearing, filling, excavation, grading, or planting of vegetation, as defined in LDC 2.00.00, a(n) formal/informal wetland jurisdictional determination or an Environmental Resource Permit (ERP) from South Florida Water Management District (SFWMD) shall be provided to verify the limits of the wetlands. Should the limits of the wetland substantially deviate from the environmental consultant’s delineation, an adjustment to the site plan and a new Wetland Waiver application shall be required in accordance with Comprehensive Plan Policy 6.1.14.4. Page 166 of 456 4) Prior to commencement of development, including, but not limited to clearing, filling, excavation, grading, or planting of vegetation, as defined in LDC 2.00.00, regarding the surface water management system for any phase of the project, the developer shall prepare a design and management plan for the littoral zone that will be established as part of these systems. 5) Prior to commencement of development, including, but not limited to clearing, filling, excavation, grading, or planting of vegetation, as defined in LDC 2.00.00, updated listed species surveys (i.e. crested caracara, gopher tortoise, etc.) shall be provided per state and/or federal survey protocol. Should any listed species be found as a result of these surveys, appropriate permits from state and federal agencies shall be required. 6) Prior to commencement of development, including, but not limited to clearing, filling, excavation, grading, or planting of vegetation, as defined in LDC 2.00.00, their successor or assigns, shall conduct a pre-construction meeting with construction personnel, all applicable state and federal regulatory agencies, and Environmental Resources Department staff to verify vegetation and preserve area protection measures have been installed. 7) Prior to issuance of a Certificate of Occupancy, all Category I listed invasive plants shall be eradicated from the site. Please contact Brian Ingram at 772-462-2393 if you have any questions or if you would like to meet regarding the details on these requirements. Page 167 of 456 LA N D S C A P E A R C H I T E C T U R E - S U R V E Y I N G CA U L F I E L D & W H E E L E R , I N C . CI V I L E N G I N E E R I N G PH O N E ( 5 6 1 ) - 3 9 2 - 1 9 9 1 / F A X ( 5 6 1 ) - 7 5 0 - 1 4 5 2 79 0 0 G L A D E S R O A D - S U I T E 1 0 0 BO C A R A T O N , F L O R I D A 3 3 4 3 4 Page 168 of 456 LA N D S C A P E A R C H I T E C T U R E - S U R V E Y I N G CA U L F I E L D & W H E E L E R , I N C . CI V I L E N G I N E E R I N G PH O N E ( 5 6 1 ) - 3 9 2 - 1 9 9 1 / F A X ( 5 6 1 ) - 7 5 0 - 1 4 5 2 79 0 0 G L A D E S R O A D - S U I T E 1 0 0 BO C A R A T O N , F L O R I D A 3 3 4 3 4 MA T C H L I N E S H E E T 3 MATCH LINE SHEET 6 Page 169 of 456 LA N D S C A P E A R C H I T E C T U R E - S U R V E Y I N G CA U L F I E L D & W H E E L E R , I N C . CI V I L E N G I N E E R I N G PH O N E ( 5 6 1 ) - 3 9 2 - 1 9 9 1 / F A X ( 5 6 1 ) - 7 5 0 - 1 4 5 2 79 0 0 G L A D E S R O A D - S U I T E 1 0 0 BO C A R A T O N , F L O R I D A 3 3 4 3 4 MATCH LINE SHEET 4 MA T C H L I N E S H E E T 2 Page 170 of 456 LA N D S C A P E A R C H I T E C T U R E - S U R V E Y I N G CA U L F I E L D & W H E E L E R , I N C . CI V I L E N G I N E E R I N G PH O N E ( 5 6 1 ) - 3 9 2 - 1 9 9 1 / F A X ( 5 6 1 ) - 7 5 0 - 1 4 5 2 79 0 0 G L A D E S R O A D - S U I T E 1 0 0 BO C A R A T O N , F L O R I D A 3 3 4 3 4 MATCH LINE SHEET 3 MA T C H L I N E S H E E T 2 MA T C H L I N E S H E E T 6 Page 171 of 456 LA N D S C A P E A R C H I T E C T U R E - S U R V E Y I N G CA U L F I E L D & W H E E L E R , I N C . CI V I L E N G I N E E R I N G PH O N E ( 5 6 1 ) - 3 9 2 - 1 9 9 1 / F A X ( 5 6 1 ) - 7 5 0 - 1 4 5 2 79 0 0 G L A D E S R O A D - S U I T E 1 0 0 BO C A R A T O N , F L O R I D A 3 3 4 3 4 MATCH LINE SHEET 4 MA T C H L I N E S H E E T 6 Page 172 of 456 LA N D S C A P E A R C H I T E C T U R E - S U R V E Y I N G CA U L F I E L D & W H E E L E R , I N C . CI V I L E N G I N E E R I N G PH O N E ( 5 6 1 ) - 3 9 2 - 1 9 9 1 / F A X ( 5 6 1 ) - 7 5 0 - 1 4 5 2 79 0 0 G L A D E S R O A D - S U I T E 1 0 0 BO C A R A T O N , F L O R I D A 3 3 4 3 4 MATCH LINE SHEET 2 MA T C H L I N E S H E E T 5 Page 173 of 456 MA T C H L I N E S H E E T 8 MATCH LINE SHEET 11 LA N D S C A P E A R C H I T E C T U R E - S U R V E Y I N G CA U L F I E L D & W H E E L E R , I N C . CI V I L E N G I N E E R I N G PH O N E ( 5 6 1 ) - 3 9 2 - 1 9 9 1 / F A X ( 5 6 1 ) - 7 5 0 - 1 4 5 2 79 0 0 G L A D E S R O A D - S U I T E 1 0 0 BO C A R A T O N , F L O R I D A 3 3 4 3 4 Page 174 of 456 LA N D S C A P E A R C H I T E C T U R E - S U R V E Y I N G CA U L F I E L D & W H E E L E R , I N C . CI V I L E N G I N E E R I N G PH O N E ( 5 6 1 ) - 3 9 2 - 1 9 9 1 / F A X ( 5 6 1 ) - 7 5 0 - 1 4 5 2 79 0 0 G L A D E S R O A D - S U I T E 1 0 0 BO C A R A T O N , F L O R I D A 3 3 4 3 4 MATCH LINE SHEET 9 MA T C H L I N E S H E E T 7 Page 175 of 456 LA N D S C A P E A R C H I T E C T U R E - S U R V E Y I N G CA U L F I E L D & W H E E L E R , I N C . CI V I L E N G I N E E R I N G PH O N E ( 5 6 1 ) - 3 9 2 - 1 9 9 1 / F A X ( 5 6 1 ) - 7 5 0 - 1 4 5 2 79 0 0 G L A D E S R O A D - S U I T E 1 0 0 BO C A R A T O N , F L O R I D A 3 3 4 3 4 MATCH LINE SHEET 8 MA T C H L I N E S H E E T 7 MA T C H L I N E S H E E T 1 1 Page 176 of 456 LA N D S C A P E A R C H I T E C T U R E - S U R V E Y I N G CA U L F I E L D & W H E E L E R , I N C . CI V I L E N G I N E E R I N G PH O N E ( 5 6 1 ) - 3 9 2 - 1 9 9 1 / F A X ( 5 6 1 ) - 7 5 0 - 1 4 5 2 79 0 0 G L A D E S R O A D - S U I T E 1 0 0 BO C A R A T O N , F L O R I D A 3 3 4 3 4 MATCH LINE SHEET 9 MA T C H L I N E S H E E T 1 1 Page 177 of 456 LA N D S C A P E A R C H I T E C T U R E - S U R V E Y I N G CA U L F I E L D & W H E E L E R , I N C . CI V I L E N G I N E E R I N G PH O N E ( 5 6 1 ) - 3 9 2 - 1 9 9 1 / F A X ( 5 6 1 ) - 7 5 0 - 1 4 5 2 79 0 0 G L A D E S R O A D - S U I T E 1 0 0 BO C A R A T O N , F L O R I D A 3 3 4 3 4 MATCH LINE SHEET 7 MA T C H L I N E S H E E T 1 0 Page 178 of 456 TRAFFIC IMPACT ANALYSIS The Club at Indrio Creek St. Lucie County, FL Prepared for: Fort Pierce Holdings GP, Inc. Prepared by: 1172 SW 30th Street, Suite 500 Palm City, FL 34990 (772) 286-8030 311001 Revised November 2025 September 2025 © MacKenzie Engineering and Planning, Inc. CA 29013 Shaun G. MacKenzie P.E. Florida License # 61751 Page 179 of 456 311001 Page i EXECUTIVE SUMMARY MacKenzie Engineering & Planning, Inc. performed an analysis of the traffic impacts resulting from the proposed project site located south of Indrio Road, east of Emerson Avenue, and west of Seminole Road, St. Luice County, FL (Parcel ID: 1314-323-0002-000-3; 1314-313-0000-000-8; 1314-331-0001-000-1; 1314-342-0001-000-5 and 1323-211-0005-000-8). The project proposed construction of 212 Single-Family Detached and 196 Mulit-Family Housing (Low-Rise) dwelling units (DUs). The buildout year is 2031. The proposed development will generate the following net new external and driveway trips: • 3,200 daily, 230 AM peak hour (60 in/170 out), and 293 PM peak hour (182 in/111 out) trips. Access to the project will be provided via the extension of Emerson Avenue and an emergency access will be provided to Seminole Road. A 235-feet southbound left-turn lane on Emerson Avenue into the project site is recommended. This project is constructing approximately 3,000 feet of the needed Indrio Road parallel facility (New East-West Road) and is constructing approximately 1,000 feet of Emerson Avenue from Indrio Road to its project entrance. Emerson Avenue and the New East-West Road are identified as future 2-lane facilities in both the TVC Element and Transportation Element of the County's Comprehensive Plan. The following needed improvements are not the responsibility of the applicant and are recommended to be the responsibility of other unapproved development projects: • Kings Highway & Indrio Road o Adjust Signal Timings o Extend Eastbound left-turn lane to 425 feet • Koblegard Road & Indrio Road o Adjust Signal Timings o Extend Turn Lanes Page 180 of 456 311001 Page ii Indrio Road from Seminole Road to Kings Highway is projected to fail due to background traffic growth. In accordance with Chapter 163.3180 F.S., the street maintaining agency has the responsibility to improve Indrio Road from Seminole Road to Kings Highway from 2-lane to 4- lanes or identify and construct an alternative parallel facility as recommended within the TVC plan. The study demonstrates that the project satisfies the County's Transportation Concurrency requirements. Page 181 of 456 311001 Page iii TABLE OF CONTENTS EXECUTIVE SUMMARY ............................................................................................................. i TABLE OF CONTENTS ............................................................................................................... iii LIST OF TABLES ......................................................................................................................... iv LIST OF FIGURES ....................................................................................................................... iv LIST OF EXHIBITS ...................................................................................................................... iv APPENDICES .................................................................................................................................v INTRODUCTION ...........................................................................................................................1 INVENTORY AND PLANNING DATA .......................................................................................2 PROJECT TRAFFIC .......................................................................................................................2 Trip Generation ................................................................................................................................2 Project Uses .....................................................................................................................................2 Internal Capture ...............................................................................................................................3 Pass-by Trip Capture........................................................................................................................3 STUDY AREA ................................................................................................................................4 TRAFFIC DISTRIBUTION AND ASSIGNMENT ........................................................................5 COMMITTED PROJECTS .............................................................................................................7 COMMITTED IMPROVEMENTS .................................................................................................7 GROWTH ........................................................................................................................................8 ROADWAY ANALYSIS ................................................................................................................9 Significance......................................................................................................................................9 Background Analysis .....................................................................................................................10 Post-Development Analysis ...........................................................................................................12 ARTERIAL ANALYSIS ...............................................................................................................14 INTERSECTION ANALYSIS ......................................................................................................14 DRIVEWAYS................................................................................................................................21 CONCLUSION ..............................................................................................................................23 APPENDICES ...............................................................................................................................25 Page 182 of 456 311001 Page iv LIST OF TABLES Table 1. Approved Trip Generation ................................................................................................ 3 Table 2. Project Impacts (Significance) ........................................................................................ 10 Table 3A. 2031 Background AM Peak Hour Roadway Analysis ............................................... 11 Table 3B. 2031 Background PM Peak Hour Roadway Analysis ................................................ 11 Table 4A. 2031 AM Post-Development Roadway analysis ........................................................ 13 Table 4B. 2031 PM Post-Development Roadway analysis ......................................................... 13 Table 5. 2031 PM Post-Development Roadway analysis ............................................................ 14 Table 6A. Intersection Analysis Summary .................................................................................. 17 Table 6B. Intersection Analysis Summary .................................................................................. 18 Table 7A. Intersection Level of Service Summary – AM ........................................................... 19 Table 7B. Intersection Level of Service Summary – PM ............................................................ 20 LIST OF FIGURES Figure 1. Site Location ................................................................................................................... 1 Figure 2. Two (2) Mile Study Radius Map .................................................................................... 4 Figure 3. Traffic Assignment ......................................................................................................... 6 Figure 4. Proposed Driveway Volumes ....................................................................................... 21 LIST OF EXHIBITS Exhibit 1 - Trip Generation Exhibit 2 - Intersection Volume Development Worksheet Exhibit 3 - Intersection Analysis Exhibit 4 - Arterial Analysis Exhibit 5 - 95th Percentile Queue Storage - Intersection Results Page 183 of 456 311001 Page v APPENDICES Appendix A - Traffic Study Methodology Appendix B - ITE Report, Trip Generation (12th Edition) Appendix C - St. Lucie TPO’s Traffic Counts and Level of Service Report (2025) Appendix D - St. Lucie TPO’s Standardized TIS Methodology and Procedures Appendix E - FDOT Peak Season Factor Category Report Appendix F - FDOT’s Q/LOS Manual 2023 Appendix G - Committed Projects Appendix H - Property Cards Appendix I - Committed Improvements Exhibit 1. Trip Generation Page 184 of 456 311001 Page 1 INTRODUCTION MacKenzie Engineering & Planning, Inc. performed an analysis of the traffic impacts resulting from the proposed project site located south of Indrio Road, east of Emerson Avenue, and west of Seminole Road, St. Luice County, FL (Parcel ID: 1314-323-0002-000-3; 1314-313-0000-000-8; 1314-331-0001-000-1; 1314-342-0001-000-5 and 1323-211-0005-000-8). The project proposed construction of 212 Single-Family Detached and 196 Mulit-Family Housing (Low-Rise) dwelling units (DUs). The buildout year is 2031. Figure 1 illustrates the site location. Figure 1. Site Location Indrio Road Se m i n o l e R o a d Em e r s o n A v e nu e Project Site Ki n g s H i g h w a y SR 6 0 7 Page 185 of 456 311001 Page 2 The applicant will construct approximately 1,000 feet of Emerson Avenue from Indrio Road to its project entrance and approximately 3,100 feet of a new East-West Road between Emerson Avenue and Seminole Road. INVENTORY AND PLANNING DATA The information contained below was used to develop the foregoing traffic analysis. • FDOT Florida Traffic Online − Traffic Count Information (2024) − Peak Season Factor Category Report (2024) − Annual Average Daily Traffic Report (2024) • MacKenzie Engineering & Planning, Inc., Turning Movement Counts • FDOT’s 2023 Quality/Level of Service Manual • St. Lucie TPO Traffic Counts and Level of Service Report (2025) • Trip Generation, 12th Edition (ITE report) PROJECT TRAFFIC Trip Generation Trip generation was approved as a part of the methodology and utilizes ITE’s Trip Generation Manual, 12th Edition (see Table 1). The study uses trip generation rates for Single Family Detached (ITE Land Use 210) and Multi-Family (Low-Rise) (ITE Land Use 220). Project Uses • 212 single family detached dwelling units (DUs) • 196 multi-family (low-rise) dwelling units (DUs) Page 186 of 456 311001 Page 3 The proposed development will generate the following net new external and driveway trips: • 3,200 daily, 230 AM peak hour (60 in/170 out), and 293 PM peak hour (182 in/111 out) trips. Internal Capture The site contains no internal capture. Pass-by Trip Capture The proposed pass-by capture is 0. Table 1. Approved Trip Generation Land Use Daily AM Peak Hour PM Peak Hour Trips Total In Out Total In Out Proposed Traffic 212 DU 1,976 148 40 108 192 119 73 Multi-family Housing (Low-rise)196 DU 1,224 82 20 62 101 63 38 3,200 230 60 170 293 182 111 3,200 230 60 170 293 182 111 Note: Trip generation was calculated using the following data: Pass-by PM Peak Hour Land Use ITE Code Unit Daily Rate Rate in/out in/out Equation 210 DU 0%27/73 62/38 220 DU 0%24/76 62/38 ITE 12th Edition Copyright © 2025, MacKenzie Engineering and Planning, Inc. Intensity Rate Single Family Detached T = 8.07(X) + 265.45 T = 0.67(X) + 5.59 Ln(T) = 0.92 Ln(X) + 0.33 Multi-family Housing (Low-rise)T = 5.63(X) + 120.45 T = 0.35(X) + 12.93 T = 0.48(X) + 7.35 Single Family Detached NET CHANGE IN TRIPS (FOR THE PURPOSES OF CONCURRENCY) NET CHANGE IN DRIVEWAY VOLUMES AM Peak Hour Page 187 of 456 311001 Page 4 STUDY AREA Based on the Approved Methodology and St. Lucie TPO Standardized TIS Methodology and Procedures, Appendix B, the area of influence for transportation concurrency is 2.0 miles. In accordance with the methodology, the study segments will be defined by section 3 of the City's standard methodology (1 percent significance on roadways within the study area and 5 percent significance on all other road segments). The significance will be based on peak hour peak direction trips and capacity. Figure 2. Two (2) Mile Study Radius Map 2-Mile Radius Indrio Rd Em e r s o n A v e Jo h n s t o n R d Ki n g s H w y Se m i n o l e R d Page 188 of 456 311001 Page 5 TRAFFIC DISTRIBUTION AND ASSIGNMENT As agreed upon in the methodology, the traffic distribution and assignment was developed based upon a select zone assignment for the project using the Treasure Coast Regional Planning Model (Version 5.1) (see Appendix A). Land use representing the buildout of the project was input into the 2045 model. The resulting traffic assignment is representative of the distribution and assignment from the model. The overall distribution is summarized by general directions and is depicted below: NORTH - 14 percent EAST - 56 percent WEST - 30 percent Page 189 of 456 311001 Page 6 Figure 3. Traffic Assignment Page 190 of 456 311001 Page 7 COMMITTED PROJECTS The following projects are approved and included as committed traffic: • 25% Preliminary Projects + 100% Buc-ee’s + 100% Approved Projects • Bedner Farms (Preliminary for Commercial) • Indrio & I-95 Development (25%) (Zoning Approval Only) (Preliminary) • Buc-ee’s • Publix at Indrio • Indrio Woods • Sabal Palm Grove • Cabo Rio RV • Indrio Groves (25%) (Not Approved) • Eagle Bend (Preliminary) • 2098 Johnston Road (Preliminary) • NVR Fort Pierce (Serenoa) • Pineapple Grove • 4540 North Kings Highway (Preliminary) • Indrio Townhomes (Preliminary) • Sea Grove COMMITTED IMPROVEMENTS Based on review of FDOT’s 5-Year Work Program and the St. Lucie TPO’s Transportation Improvement Program, which includes St. Lucie County’s 5-Year Capital Improvement Plan. The following improvement is identified in the plans to add capacity within the study area: • Kings Highway (SR 713) – St. Lucie Boulevard to Indrio Road – 4-Laning – ROW 2027 • SR-68/Orange Avenue from SR-713/Kings Highway to E of SR-9/I-95 SB Ramp – Interchange Improvements – 2029 Page 191 of 456 311001 Page 8 • Oslo Road - 82nd Ave to 58th Ave – 4-Laning – Under Construction • Oslo Road & I-95 Interchange – Under Construction • Buc-ees Committed Improvements: 1. Construct a 2nd northbound right-turn lane and urbanize the northbound right-turn off ramp at the intersection of I-95 northbound Ramp. Urbanizing the turn lane includes signalizing the movement, reducing the turning radius, and removing the free flow condition. 2. Coordinate the I-95 northbound and southbound ramp signals with the intersection of Indrio Road & Koblegard Road. 3. Construct approximately 1,250 feet of Koblegard Road as a 4-lane facility south of Indrio Road and construct the northbound approach at the intersection of Indrio Road & Koblegard Road with the following: a. Two northbound left turn lanes b. One northbound through lane c. One northbound right turn lane 4. Make additional improvements at the intersection of Indrio & Koblegard Road, including a. Construct one eastbound right turn lane b. Extend the westbound left turn lane 5. Construct an ingress-only driveway approximately 440 feet west of the intersection of Indrio Road & Koblegard Road, outside of FDOT limited access right-of-way (ROW). GROWTH As agreed in the methodology, the existing peak hour traffic volumes will be increased based on the greater of the annual compound growth rate of 3.8% or a 1% growth rate plus approved site plan traffic to develop the projected year 2031 background traffic volumes. Page 192 of 456 311001 Page 9 ROADWAY ANALYSIS Roadway Capacity As agreed to in the methodology, Roadway classification follows the St. Lucie Comprehensive Plan outlining the roadway functional classification. The St. Lucie County Transportation Element outlines the minimum Level of Service (LOS) for each roadway functional classification. Roadway Capacity is based on the St. Lucie TPO’s 2025 Level of Service Report for non-state roadways. Where road segment information is not available, the study uses St. Lucie County’s minimum LOS standards to apply FDOT’s 2023 Multimodal Quality/LOS Handbook. Indrio Road will be classified as C3R or C3C (as appropriate based on pending development) to provide a conservative analysis. Significance Traffic assignment was compared to the roadway capacities and roadway segments within 2 miles of the property. The study area is 2 miles based on the County Code , and impacts of greater than one percent (1%) within the 2 mile study are and five percent (5%) beyond 2 miles are considered to have significant impact in accordance with the County’s “Standardized Traffic Impact Studies Methodology and Procedures”. Table 2 displays the roadway segments with significant impact. Page 193 of 456 311001 Page 10 Table 2. Project Impacts (Significance) Background Analysis The 2024 peak hour traffic volumes were increased based on the greater of the annual compound growth rate or a 1% growth rate plus committed traffic to develop the projected year 2031 background traffic volumes. The background 2031 traffic volumes were compared to the service volumes for each respective roadway segment to determine if the road is projected to operate acceptably as shown in Tables 4A & 4B. The committed project traffic are located in Appendix G. Indrio Road from Seminole Road to Kings Highway are projected to fail due to background traffic growth. In accordance with Chapter 163.3180 F.S., the street maintaining agency has the responsibility improve adding turn lanes to Kings Highway from Spanish Lakes Boulevard to St. Lucie Boulevard and Indrio Road from Emerson Avenue to Kings Highway from 2-lane to 4-lanes. The proposed analysis with project traffic includes the one needed improvement as existing in accordance with Chapter 163.3180 F.S. Based on the analysis, the remaining road segments are projected to operate acceptably as shown in Tables 3A and 3B. NB/EB SB/WB NB/EB SB/WB NB/EB SB/WB 25th St SW to Russos Road 2 C2 1,070 7%8 13 0.75%1.21%NO NO Russos Road to Indrio Road 2 C2 1,070 7%8 13 0.75%1.21%NO YES Indrio Rd to Old Johnston Rd 2 C2 1,070 8%15 9 1.40%0.84%YES NO Old Johnston Rd to Meadowood Dr 2 C2 1,070 1%2 1 0.19%0.09%NO NO Fort Pierce Blvd to Russos Road 2 C2 760 11%12 20 1.58%2.63%NO NO Russos Road to Indrio Road*2 C3R 1,110 14%16 25 1.44%2.25%YES YES Indrio Road to Driveway*2 C3R 1,110 100%111 182 10.00%16.40%YES YES US 1 to Spanish Lakes Blvd 2 C3R 1,110 4%4 7 0.36%0.63%NO NO Spanish Lakes Blvd to Indrio Road*2 C3R 1,110 8%9 15 0.81%1.35%NO YES Indrio Rd to St. Lucie Blvd*2 C3C 1,070 29%53 32 4.95%2.99%YES YES St. Lucie Blvd to Angle Road*2 C3C 1,070 15%27 17 2.52%1.59%NO NO Private Rd to I-95 2 C2 1,080 0.0%0 0 0.00%0.00%NO NO I-95 to Koblegard Rd*4 C3C 1,810 9.0%16 10 0.88%0.55%NO NO Koblegard Road to Johnston Road*4 C3C 1,810 15.0%27 17 1.49%0.94%YES NO Johnston Road to Emerson Ave*4 C3R 1,850 30%55 33 2.97%1.78%YES YES Emerson Ave to Seminole Rd*2 C3R 1,110 56%62 102 5.59%9.19%YES YES Seminole Rd to Kings Hwy*2 C3R 1,110 50%56 91 5.05%8.20%YES YES Kings Hwy to Slash Pine Trl*2 C3R 1,110 13%14 24 1.26%2.16%YES YES Slash Pine Trl to US 1*2 C3R 1,110 10%11 18 0.99%1.62%NO NO Koblegard Road Indrio Road to 25th St SW*2 C3R 1,110 5%6 9 0.54%0.81%NO NO * Roadway Capacity based on FDOT Area Type Project Traffic Impact Significant Impact? (Y/N)Roadway Segments E + C Lanes Area Tpe Capacity Assign Johnston Road Emerson Ave Indrio Road Kings Hwy Page 194 of 456 311001 Page 11 Table 3A. 2031 Background AM Peak Hour Roadway Analysis Table 3B. 2031 Background PM Peak Hour Roadway Analysis NB/EB SB/WB NB/EB SB/WB NB/EB SB/WB NB/EB SB/WB NB/EB SB/WB NB/EB SB/WB NB/EB SB/WB NB/EB SB/WB Russos Road to Indrio Road 2 1070 2024 419 429 1.00 419 429 121 98 3.8%125 128 151 129 570 558 YES YES Indrio Rd to Old Johnston Rd 2 1070 2024 100 78 1.00 100 78 116 111 3.8%30 23 124 117 224 195 YES YES Russos Road to Indrio Road 2 1110 2024 251 407 1.00 251 407 53 80 3.8%75 121 71 109 326 528 YES YES Indrio Road to Driveway 2 1,110 2024 3 3 1.00 3 3 0 1 3.8%1 1 0 1 4 4 YES YES Spanish Lakes Blvd to Indrio Rd 2 1,110 2024 507 755 1.00 507 755 157 95 3.8%151 225 193 149 700 980 YES YES Indrio Rd to St. Lucie Blvd 2 1,070 2024 518 738 1.00 518 738 146 140 3.8%155 220 184 193 702 958 YES YES Koblegard Rd to Johnston Rd 4 1,810 2024 704 847 1.00 704 847 307 217 3.8%210 253 358 278 1062 1125 YES YES Johnston Rd to Emerson Ave 4 1,850 2024 582 471 1.00 582 471 190 268 3.8%174 141 232 302 814 773 YES YES Emerson Ave to Seminole Rd 2 1,110 2024 493 453 1.00 493 453 274 213 3.8%147 135 309 246 802 699 YES YES Seminole Rd to Kings Hwy 2 1,110 2024 589 494 1.00 589 494 305 210 3.8%176 147 347 245 936 739 YES YES Add 4 Lanes 1850 YES YES Kings Hwy to Slash Pine Trl 2 1,110 2024 334 236 1.00 334 236 113 134 3.8%100 70 137 151 471 387 YES YES Appendix G Needed Improvement Improved Capacity Johnston Road Emerson Ave Indrio Road Kings Hwy Total Committed Traffic Committed Traffic + 1% Growth rate Acceptable?Acceptable? Roadway Segment E + C Lanes Roadway Capacity Existing Peak Hour Peak Direction Volumes Peak season Peak Hour Direction Volumes 2031 BackgroundReference Growth from Historic Growth RateCount year PSCF Growth Rate NB/EB SB/WB NB/EB SB/WB NB/EB SB/WB NB/EB SB/WB NB/EB SB/WB NB/EB SB/WB NB/EB SB/WB NB/EB SB/WB Russos Road to Indrio Road 2 1070 2024 460 503 1.00 460 503 149 161 3.8%137 150 183 197 643 700 YES YES Indrio Rd to Old Johnston Rd 2 1070 2024 120 125 1.00 120 125 160 156 3.8%36 37 168 165 288 290 YES YES Russos Road to Indrio Road 2 1110 2024 506 236 1.00 506 236 85 133 3.8%151 70 122 150 657 386 YES YES Indrio Road to Driveway 2 1110 2024 4 3 1.00 4 3 0 3 3.8%1 1 0 3 5 6 YES YES Spanish Lakes Blvd to Indrio Rd 2 1110 2024 656 579 1.00 656 579 183 209 3.8%196 173 230 251 886 830 YES YES Indrio Rd to St. Lucie Blvd 2 1070 2024 799 569 1.00 799 569 163 209 3.8%238 170 220 250 1037 819 YES YES Koblegard Rd to Johnston Rd 4 1810 2024 909 776 1.00 909 776 358 425 3.8%271 231 424 481 1333 1257 YES YES Johnston Rd to Emerson Ave 4 1850 2024 516 687 1.00 516 687 375 317 3.8%154 205 412 366 928 1053 YES YES Emerson Ave to Seminole Rd 2 1110 2024 551 643 1.00 551 643 374 405 3.8%164 192 413 451 964 1094 YES YES Seminole Rd to Kings Hwy 2 1110 2024 626 761 1.00 626 761 351 317 3.8%187 227 396 372 1022 1133 YES NO Add 4 Lanes 1850 YES YES Kings Hwy to Slash Pine Trl 2 1110 2024 337 493 1.00 337 493 149 149 3.8%101 147 174 184 511 677 YES YES Appendix G Needed Improvement Acceptable? Johnston Road Emerson Ave Kings Hwy Indrio Road Roadway Segment E + C Lanes Roadway Capacity Count year Existing Peak Hour Peak Direction Volumes Total Committed Traffic Growth Rate Growth from Historic Growth Rate Committed Traffic + 1% Growth rate Improved Capacity Acceptable? PSCF Reference Peak season Peak Hour Direction Volumes 2031 Background Page 195 of 456 311001 Page 12 Post-Development Analysis The post-development 2031 traffic volumes were developed by adding 2031 background traffic volume (from Tables 4A and 4B) plus project traffic. The post-development 2031 traffic volumes were compared to the service volumes for each respective roadway segment to determine if the road is projected to operate acceptably. Kings Highway (northbound) from Indrio Road to St. Lucie Boulevard and Indrio Road (westbound) from Emerson Ave to Seminole Road exceed the generalized service volume. Based on the analysis, the remaining road segments are projected to operate acceptably in 2031 with the projected development as shown in Tables 4A and 4B. Detailed arterial analysis will be required for Kings Highway from Indrio Road to St. Lucie Boulevard and Indrio Road from Emerson Ave to Seminole Road to determine if the road will operate acceptably. Page 196 of 456 311001 Page 13 Table 4A. 2031 AM Post-Development Roadway analysis Table 4B. 2031 PM Post-Development Roadway analysis NB/EB SB/WB NB/EB SB/WB NB/EB SB/WB NB/EB SB/WB Russos Road to Indrio Road 2 1070 570 558 7%12 4 582 562 YES YES Indrio Rd to Old Johnston Rd 2 1070 224 195 8%5 14 229 209 YES YES Russos Road to Indrio Road 2 1110 326 528 14%24 8 350 536 YES YES Indrio Road to Driveway 2 1110 4 4 100%170 60 174 64 YES YES Spanish Lakes Blvd to Indrio Rd 2 1110 700 980 8%14 5 714 985 YES YES Indrio Rd to St. Lucie Blvd 2 1070 702 958 29%17 49 719 1007 YES YES Koblegard Rd to Johnston Rd 4 1810 1062 1125 15%9 26 1071 1151 YES YES Johnston Rd to Emerson Ave 4 1850 814 773 30%18 51 832 824 YES YES Emerson Ave to Seminole Rd 2 1110 802 699 56%95 34 897 733 YES YES Seminole Rd to Kings Hwy 4 1850 936 739 50%85 30 1021 769 YES YES Kings Hwy to Slash Pine Trl 2 1110 471 387 13%22 8 493 395 YES YES 2031 Buildout2031 BackgroundRoadway Segment E + C Lanes + Needed Improv Roadway Capacity Assign Project Traffic Acceptable? Johnston Road Emerson Ave Kings Hwy Indrio Road NB/EB SB/WB NB/EB SB/WB NB/EB SB/WB NB/EB SB/WB Russos Road to Indrio Road 2 1070 643 700 7%8 13 651 713 YES YES Indrio Rd to Old Johnston Rd 2 1070 288 290 8%15 9 303 299 YES YES Russos Road to Indrio Road 2 1110 657 386 14%16 25 673 411 YES YES Indrio Road to Driveway 2 1110 5 6 100%111 182 116 188 YES YES Spanish Lakes Blvd to Indrio Rd 2 1110 886 830 8%9 15 895 845 YES YES Indrio Rd to St. Lucie Blvd 2 1070 1037 819 29%53 32 1090 851 Yes YES Koblegard Rd to Johnston Rd 4 1810 1333 1257 15%27 17 1360 1274 YES YES Johnston Rd to Emerson Ave 4 1850 928 1053 30%55 33 983 1086 YES YES Emerson Ave to Seminole Rd 2 1110 964 1094 56%62 102 1026 1196 YES Yes Seminole Rd to Kings Hwy 4 1850 1022 1133 50%56 91 1078 1224 YES YES Kings Hwy to Slash Pine Trl 2 1110 511 677 13%14 24 525 701 YES YES *See deatiled Arterial Analysis Acceptable?E + C Lanes + Needed Improv Roadway Capacity 2031 Background Assign Project Traffic 2031 Buildout Roadway Segment Johnston Road Emerson Ave Kings Hwy Indrio Road * * Page 197 of 456 311001 Page 14 ARTERIAL ANALYSIS Arterial analyses were performed to determine the operation on Kings Highway (northbound) from Indrio Road to St. Lucie Boulevard and Indrio Road (westbound) from Emerson Ave to Seminole Road. The roadways were examined for AM and PM peak hour conditions. The arterial analyses were performed using Synchro 12. The analysis used speed limit data obtained from aerial and ground photography. The speed results obtained from the software were compared to the levels of service in the Highway Capacity Manual – 7th Edition. The arterial analysis results are shown in Exhibit 4. Table 5. 2031 PM Post-Development Roadway analysis Roadway From To AM (MPH/LOS) PM (MPH/LOS) Meets Los NB WB NB WB Kings Highway Indrio Road St. Lucie Boulevard 42.8/A - 40.9/B - Yes Indrio Road Emerson Ave Seminole Road - 25.6/C - 24.3/C Yes Based on the detailed arterial analysis, King Highway from St. Lucie Boulevard to Indrio Road and Indrio Road from Emerson Avenue to Seminole Road are projected to operate acceptably. INTERSECTION ANALYSIS Intersections The intersections within the study area were evaluated in Existing, 2031 pre-development (background), and 2031 post development (pre-development traffic plus committed plus project traffic) conditions. This study analyzes the impacts to the following intersections for the AM and PM peak hours: Page 198 of 456 311001 Page 15 • Indrio Road & Koblegard Road • Indrio Road & Johnston Road • Indrio Road & Emerson Avenue • Indrio Road & Seminole Road • Indrio Road & Kings Highway Data from the existing facilities within the study area were collected based on aerial photography and site observations. MacKenzie Engineering and Planning, Inc. collected AM and PM peak hour turning movement counts. The counts were adjusted to peak season conditions using FDOT’s peak season adjustment factors. The intersection laneage, average delay per vehicle, and LOS are shown in Tables 6A, 6B, 7A, and 7B. The detailed intersection analysis is contained in Exhibit 3, and the queue summary is contained in Exhibit 5. Analysis Indrio Road & Koblegard Road MEP evaluated the Indrio Road & Koblegard Road intersection using Synchro 12. With project traffic, the intersection is projected to operate acceptably with all movements operating under capacity (v/c ratio less than 1.0). The intersection is projected to operate acceptably. Turn lane extensions are needed for the eastbound left, westbound left, southbound left, southbound right and westbound right as a result of committed and anticipated traffic. No turn lane extensions are needed as a result of the project. Indrio Road & Johnston Road MEP evaluated the Indrio Road & Johnston Road intersection using Synchro 12. With project traffic, the intersection is projected to operate acceptably with all movements operating under capacity (v/c ratio less than 1.0). The intersection is projected to operate acceptably. Indrio Road & Emerson Avenue MEP evaluated the Indrio Road & Emerson Avenue intersection using Synchro 12. With project traffic, the intersection is projected to operate acceptably with all movements operating under capacity (v/c ratio less than 1.0). The intersection is projected to operate acceptably. Page 199 of 456 311001 Page 16 Indrio Road & Seminole Road MEP evaluated the Indrio Road & Seminole Road intersection using Synchro 12. With project traffic, the intersection is projected to operate acceptably with all movements operating under capacity (v/c ratio less than 1.0). The intersection is projected to operate acceptably. Indrio Road & Kings Highway MEP evaluated the Indrio Road & Kings Highway intersection using Synchro 12. With project traffic, the intersection is projected to operate acceptably with all movements operating under capacity (v/c ratio less than 1.0). The eastbound left-turn lane needs to be extended to 475 feet with project traffic, which is a 50-foot increase compared the pre-development condition. Page 200 of 456 311001 Page 17 Table 6A. Intersection Analysis Summary Kings Hwy AM PM Kings Hwy AM PM Kings Hwy AM PM 27.8 29.5 33.2 42.0 33.7 45.7 C C C D C D Indrio Road Indrio Road Indrio Road Seminole Road AM PM Seminole Road AM PM Seminole Road AM PM 0.1 0.2 0.2 0.4 0.2 0.5 A A A A A A Indrio Road Indrio Road Indrio Road AM PM AM PM AM PM 16.4 21.7 22 24.1 28.4 31.5BCCCCC Indrio Road Indrio Road Indrio Road 3 Emerson Avenue Emerson Avenue Emerson Avenue 2 1 Existing Committed / Background Background Needs Improvement Post-Development Legend: Improvements Page 201 of 456 311001 Page 18 Table 6B. Intersection Analysis Summary AM PM AM PM AM PM 28.9 28.6 33.2 34.5 33.7 34.9 C C C C D C Indrio Road Indrio Road Indrio Road AM PM AM PM AM PM 6.6 8.7 33.6 50.0 34.1 51.6 A A C D C D Indrio Road Indrio Road Indrio Road 5 4 Jonhston Road Jonhston Road Jonhston Road Koblegard Road Koblegard Road Koblegard Road Existing Committed / Background Background Needs Improvement Post-Development Legend: Improvements Page 202 of 456 311001 Page 19 Table 7A. Intersection Level of Service Summary – AM v/c ratio Delay LOS v/c ratio Delay LOS v/c ratio Delay LOS v/c ratio Delay LOS v/c ratio Delay LOS v/c ratio Delay LOS v/c ratio Delay LOS v/c ratio Delay LOS v/c ratio Delay LOS v/c ratio Delay LOS v/c ratio Delay LOS v/c ratio Delay LOS Delay LOS 2025 Existing 0.39 21.1 C 0.2 22.2 C 0.26 23 C 0.13 23 C 0.21 26.5 C 0.04 25.4 C 0.7 42.5 D 0.41 25.3 C 0.03 22.4 C 0.59 39.2 D 0.59 27.7 C 0.18 24.1 C Total 2031 Pre 0.66 30.8 C 0.35 29.3 C 0.12 27.4 C 0.24 30.4 C 0.43 36 D 0.07 33 C 0.75 46 D 0.44 26.4 C 0.02 22.4 C 0.68 46.9 D 0.66 31.2 C 0.09 24.8 C Total 2031 Post 0.71 33.4 C 0.38 30 C 0.26 29.3 C 0.25 30.8 C 0.45 36.6 D 0.07 33.4 C 0.76 46.6 D 0.43 26.2 C 0.02 22.3 C 0.69 47.3 D 0.67 31.5 C 0.1 25.2 C Total 2025 Existing 0.025 19.6 C Total 2031 Pre 0.066 39.7 E Total 2031 Post 0.025 47.6 E Total 2025 Existing 0.38 20 C 0.31 12.7 B 0 0 A 0.29 65.4 E 0.58 18.6 B 0.07 16.2 B 0 0 A 0 0 A 0 0 A 0.28 16.8 B 0 0 A 0.06 11.3 B Total 2031 Pre 0.64 30.3 C 0.49 16.4 B 0 0 A 0.31 80.2 F 0.7 22.8 C 0.05 18.1 B 0 0 A 0 0 A 0.24 46.9 D 0.51 26.5 C 0 0 A 0.05 18.5 B Total 2031 Post 0.68 36.3 D 0.6 23.7 C 0.03 19.1 B 0.45 39.4 D 0.73 27.8 C 0.06 22 C 0.27 31.9 C 0 0 A 0.28 32 C 0.61 33.2 C 0 0 A 0.06 23.4 C Total 2025 Existing 0.73 36.2 D 0.42 22.9 C 0.01 19.9 B 0.4 41 D 0.72 30.9 C 0.06 25.3 C 0.06 28.6 C 0.22 29.7 C 0.01 25.5 C 0.15 27.8 C 0.14 27.8 C 0.1 19.7 B Total 2031 Pre 0.8 41.8 D 0.55 24.6 C 0.01 19.5 B 0.7 51.9 D 0.78 33.9 C 0.02 25.8 C 0.16 35.5 D 0.39 37.5 D 0.01 29.5 C 0.26 36.3 D 0.29 36.5 D 0.07 23.1 C Total 2031 Post 0.81 42.6 D 0.56 24.9 C 0.01 19.6 B 0.78 54.8 D 0.79 34 C 0.05 25.8 C 0.16 36.3 D 0.4 38.3 D 0.02 29.7 C 0.28 37.3 D 0.3 37.3 D 0.07 23.7 C Total 2025 Existing 0.24 18.4 B 0.34 3.8 A 0 0 A 0 0 A 0.59 7.7 A 0 0 A 0.25 16.6 B 0 0 A 0.02 14.9 B Total 2031 Pre 0.66 52.7 D 0.67 26 C 0.07 19.2 B 0.8 56.1 E 0.83 27.7 C 0.04 16.9 B 0.84 43.4 D 0.06 33.5 C 0.06 33.5 C 0.74 47.9 D 0 0 A 0.2 38.2 D Total 2031 Post 0.66 53.7 D 0.67 26.3 C 0.07 19.3 B 0.7 56.9 E 0.83 28.1 C 0.05 17 B 0.85 44.4 D 0.06 34.2 C 0.06 34.2 C 0.75 48.9 D 0 0 A 0.2 38.9 D Total - -- -- -- 29.9 34.5 34.8 25.5 32 32.4 33.2 15.4 23.7 31.3 33.7 34.1 19.57 39.65 47.59 0 31.9 46.9 C B 21.9 29.9 31.3 15.1 20 26.9 28.4 31.1 31.4 4.3 25.5 34.5 35 18.6 5 Indrio Road & Koblegard Road 4 Indrio Road & Johnston Road 3 Indrio Road & Emerson Avenue 2 Indrio Road & Semniole Road EBL EBT EBR WBL WBT 28.6 28.9 34.1 CCCDD30.3 43.7 46.3 6.6 AAA7.7 16.4- 33.6 CCCDD3042.7 45.4 33.7 CCDDC3637.1 28.9 CCCC31.2 29.1 C 33.2 CCDDC35.6 36.6 28.4 CCCCC28.2 16.4 BBBAB 22 CCCDC22.8 0.2 AE -- 0.1 AC 0.2 AE CCDCC 1 Indrio Road & Kings Highway 27.8 CCCC 33.2 C 33.7 C TOTAL C C C WBR NBL NBT NBR SBL SBT SBR No.Intersection Period Page 203 of 456 311001 Page 20 Table 7B. Intersection Level of Service Summary – PM v/c ratio Delay LOS v/c ratio Delay LOS v/c ratio Delay LOS v/c ratio Delay LOS v/c ratio Delay LOS v/c ratio Delay LOS v/c ratio Delay LOS v/c ratio Delay LOS v/c ratio Delay LOS v/c ratio Delay LOS v/c ratio Delay LOS v/c ratio Delay LOS Delay LOS 2025 Existing 0.59 22.7 C 0.22 23.2 C 0.07 22.2 C 0.25 25 C 0.47 30.8 C 0.32 30.2 C 0.69 37.2 D 0.54 27.6 C 0.13 24 C 0.43 39.5 D 0.58 32.7 C 0.16 29.1 C Total 2031 Pre 0.91 49.9 D 0.35 30.3 C 0.15 28.3 C 0.36 33 C 0.67 43.7 D 0.05 36.5 D 0.83 54.7 D 0.59 33.5 C 0.03 26.8 C 0.67 59 E 0.68 43 D 0.16 36.7 D Total 2031 Post 0.93 56.8 E 0.35 32 C 0.1 29.3 C 0.36 35.1 D 0.68 46.9 D 0.05 38.9 D 0.86 58.9 E 0.57 34.8 C 0.03 28 C 0.68 64.2 E 0.69 47.1 D 0.21 40.8 D Total 2025 Existing 0.047 18.6 C Total 2031 Pre 0.185 54.9 F Total 2031 Post 0.234 71.7 F Total 2025 Existing 0.67 27 C 0.38 16.1 B 0 0 A 0.3 52.8 D 0.64 23.4 C 0.16 20.5 C 0 0 A 0.2 39.3 D 0 0 A 0.27 22.9 C 0 0 A 0.03 15.7 B Total 2031 Pre 0.77 35.7 D 0.46 14.3 B 0 11 B 0.3 56.3 E 0.75 25.1 C 0.25 19.9 B 0 0 A 0.2 46.6 D 0 0 A 0.51 34.8 C 0 0 A 0.05 21.7 C Total 2031 Post 0.8 41.5 D 0.57 22.7 C 0.02 17.6 B 0.78 51.3 D 0.78 29.9 C 0.26 23.7 C 0.22 10.2 B 0 0 A 0.23 40.3 D 0.69 42.5 D 0 0 A 0.05 26.4 C Total 2025 Existing 0.73 33.9 C 0.64 25.4 C 0.01 20.5 C 0.4 38.7 D 0.68 30.8 C 0.11 26.6 C 0.05 27.1 C 0.21 28.1 C 0.01 24 C 0.23 26.4 C 0.22 26.3 C 0.06 17.4 B Total 2031 Pre 0.81 42.8 D 0.69 26.9 C 0.02 19.6 B 0.78 55.2 E 0.79 34.5 C 0.03 26 C 0.2 37.4 D 0.44 39.5 D 0.03 30.3 C 0.4 39.1 D 0.49 40 D 0.06 23.6 C Total 2031 Post 0.82 43.3 D 0.71 27.6 C 0.02 19.8 B 0.79 54.9 D 0.79 34.5 C 0.04 26 C 0.2 37.9 D 0.44 40 D 0.05 30.4 C 0.46 40.2 D 0.49 40.6 D 0.06 24 C Total 2025 Existing 0.27 16.1 B 0.57 7.5 A 0 0 A 0.39 58.3 E 0.53 8.6 A 0 0 A 0.27 15.3 B 0 0 A 0.02 12.7 B Total 2031 Pre 0.86 69.6 E 0.88 44.2 D 0.09 26.3 C 0.85 83.8 F 0.75 39.2 D 0.13 28.4 C 0.9 57.3 E 0.07 37.6 D 0.08 37.7 D 0.82 64.6 E 0 0 A 0.18 41.5 D Total 2031 Post 0.86 72.2 E 0.88 45.3 D 0.09 26.9 C 0.86 83.9 F 0.75 40 D 0.13 29.2 C 0.9 59.2 E 0.07 39.3 D 0.08 39.5 D 0.84 68.3 E 0 0 A 0.1 42.5 D Total - - -- -- - 51.6 D50.4 D 44.6 D 55.7 E 63.6 E 55.8 E 58.1 E5Indrio Road & Koblegard Road 8.7 A8.1 A 8.7 A 15 B 50 D49D44D 34.9 C32.7 C 36.7 D 37.9 D 37.3 D 28.6 C28.4 C 31.1 C 27.6 C 34.5 C32.1 C 36.7 D 38 D 36.4 D 23.9 C 29 C 31.3 C 40.3 D 40.3 D 4 Indrio Road & Johnston Road 3 Indrio Road & Emerson Avenue 21.7 C20.5 C 23.3 C 39.3 D 21.9 C 24.1 C21.5 C 24.6 C 46.6 D 32.9 C 31.5 C F 31.5 C71.74 F - --2 Indrio Road & Semniole Road 21.7 C18.59 C 24.1 C54.9 45.7 D44.1 D 44.1 D 45.4 D 49.8 D D 42.2 D 45.7 D NBL NBT NBR SBL SBT SBR TOTAL 1 Indrio Road & Kings Highway 29.5 C22.9 C 29.5 C 31.1 C 33.7 C 42 D39.7 D 41.1 No.Intersection Period EBL EBT EBR WBL WBT WBR Page 204 of 456 311001 Page 21 DRIVEWAYS Driveway Access The project provides two points of access: • Driveway 1 – Emerson Avenue – Full Opening • Driveway 2 – Seminole Avenue – Emergency Only Figure 4 shows the proposed project driveway volumes. Figure 4. Proposed Driveway Volumes (in) 14% (25) 8 34 (102)56%(in)56%(in) Indrio Road (in)30%(55)18 (out)56% 51 24 95 (33)(16)(62) 30%14%56% (out)(out)(out)In Out In Out 60 170 182 111 100% (182) 60 170 (111)100% 0 0 0% 0 0 0% 3,200 293 230 THE CLUB AT INDRIO CREEK PROPOSED PROJECT DRIVEWAY TRAFFIC Total Daily Driveway Trips PM Peak Hour Trips AM Peak Hour Trips Em e r s o n A v e n u e Se m i n o l e R o a d PROJECT DRIVEWAY TRIPS Daily AM Peak Hour PM Peak Hour Total Total DW 1 DW 2 (Emergency Only) 3,200 230 293 Project Site Page 205 of 456 311001 Page 22 Driveway Analysis Driveway 1 (Emerson Avenue) MEP evaluated the Emerson Avenue & Driveway 1 intersection. A left-turn lane is not required in the existing condition because Emerson Avenue does not extend past the project. However, a left-turn lane is recommended based on the future extension of Emerson Avenue to Immokolee Road. A 235-feet southbound left-turn lane is recommended based on queue storage of 50 feet and design speed of 45 mph. With project traffic, the intersection is projected to operate acceptably with all movements operating under capacity (v/c ratio less than 1.0). The intersection is projected to operate acceptably. Direction Queue Length Decel Distance (45 MPH) (in Feet) Required Turn Lane (in Feet) Southbound Left 50 Feet 185 235 Page 206 of 456 311001 Page 23 CONCLUSION MacKenzie Engineering & Planning, Inc. performed an analysis of the traffic impacts resulting from the proposed project site located south of Indrio Road, east of Emerson Avenue, and west of Seminole Road, St. Luice County, FL (Parcel ID: 1314-323-0002-000-3; 1314-313-0000-000-8; 1314-331-0001-000-1; 1314-342-0001-000-5 and 1323-211-0005-000-8). The project proposed construction of 212 Single-Family Detached and 196 Mulit-Family Housing (Low-Rise) dwelling units (DUs). The buildout year is 2031. The proposed development will generate the following net new external and driveway trips: • 3,200 daily, 230 AM peak hour (60 in/170 out), and 293 PM peak hour (182 in/111 out) trips. Access to the project will be provided via the extension of Emerson Avenue and an emergency access will be provided to Seminole Road. A 235-feet southbound left-turn lane on Emerson Avenue into the project site is recommended. This project is constructing approximately 3,000 feet of the needed Indrio Road parallel facility (New East-West Road) and is constructing approximately 1,000 feet of Emerson Avenue from Indrio Road to its project entrance. Emerson Avenue and the New East-West Road are identified as future 2-lane facilities in both the TVC Element and Transportation Element of the County's Comprehensive Plan. The following needed improvements are not the responsibility of the applicant and are recommended to be the responsibility of other unapproved development projects: • Kings Highway & Indrio Road o Adjust Signal Timings o Extend Eastbound left-turn lane to 425 feet • Koblegard Road & Indrio Road o Adjust Signal Timings o Extend Turn Lanes Page 207 of 456 311001 Page 24 Indrio Road from Seminole Road to Kings Highway is projected to fail due to background traffic growth. In accordance with Chapter 163.3180 F.S., the street maintaining agency has the responsibility to improve Indrio Road from Seminole Road to Kings Highway from 2-lane to 4- lanes or identify and construct an alternative parallel facility as recommended within the TVC plan. The study demonstrates that the project satisfies the County's Transportation Concurrency requirements. Page 208 of 456 311001 Page 25 APPENDICES Appendix A - Traffic Study Methodology Appendix B - ITE Report, Trip Generation (12th Edition) Appendix C - St. Lucie TPO’s Traffic Counts and Level of Service Report (2025) Appendix D - St. Lucie TPO’s Standardized TIS Methodology and Procedures Appendix E - FDOT Peak Season Factor Category Report Appendix F - FDOT’s Q/LOS Manual 2023 Appendix G - Committed Projects Appendix H - Property Cards Appendix I - Committed Improvements Page 209 of 456 THE CLUB AT INDRIO CREEK Land Use Daily AM Peak Hour PM Peak Hour Trips Total In Out Total In Out Proposed Traffic 212 DU 1,976 148 40 108 192 119 73 Multi-family Housing (Low-rise)196 DU 1,224 82 20 62 101 63 38 3,200 230 60 170 293 182 111 3,200 230 60 170 293 182 111 Note: Trip generation was calculated using the following data: Pass-by PM Peak Hour Land Use ITE Code Unit Daily Rate Rate in/out in/out Equation 210 DU 0% 27/73 62/38 220 DU 0% 24/76 62/38 ITE 12th Edition Copyright © 2025, MacKenzie Engineering and Planning, Inc. Single Family Detached NET CHANGE IN TRIPS (FOR THE PURPOSES OF CONCURRENCY) NET CHANGE IN DRIVEWAY VOLUMES AM Peak Hour Intensity Exhibit 1 Rate Single Family Detached T = 8.07(X) + 265.45 T = 0.67(X) + 5.59 Ln(T) = 0.92 Ln(X) + 0.33 Multi-family Housing (Low-rise)T = 5.63(X) + 120.45 T = 0.35(X) + 12.93 T = 0.48(X) + 7.35 Page 210 of 456 AM PEAK HOUR TURNING MOVEMENTS & Count Taken:2/7/2024 ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr totals 7:00 AM 7:15 AM 2 27 24 59 0 11 25 7 2 37 62 9 1 19 104 26 415 7:15 AM 7:30 AM 4 38 38 49 0 16 21 13 0 39 62 8 4 22 115 27 456 7:30 AM 7:45 AM 8 40 42 45 0 5 32 6 1 51 78 7 1 30 109 44 499 7:45 AM 8:00 AM 5 35 51 65 0 11 24 9 1 39 82 6 2 43 121 35 529 8:00 AM 8:15 AM 8 55 43 44 0 12 31 6 3 46 76 3 1 26 87 37 478 8:15 AM 8:30 AM 5 46 29 60 0 18 23 14 1 26 64 4 0 21 94 31 4368:30 AM 8:45 AM 5 40 36 56 0 8 16 8 2 30 89 3 2 28 90 26 439 8:45 AM 9:00 AM 5 22 36 48 1 12 24 13 0 29 67 7 2 23 74 18 381 42 303 299 426 1 93 196 76 10 297 580 47 13 212 794 244 3633 7:15 AM 8:15 AM 25 168 174 203 0 44 108 34 5 175 298 24 8 121 432 143 1962 Count Taken:2/8/2024 ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr totals 7:00 AM 7:15 AM 4 33 28 48 0 13 32 8 0 37 68 7 1 21 106 28 434 7:15 AM 7:30 AM 2 33 40 60 0 18 30 8 1 43 86 9 1 27 123 35 516 7:30 AM 7:45 AM 10 35 41 49 0 12 39 9 0 39 71 4 1 37 120 53 5207:45 AM 8:00 AM 10 43 40 73 0 9 26 5 0 44 86 4 2 39 111 40 532 8:00 AM 8:15 AM 3 46 51 53 0 8 37 10 2 50 69 10 2 32 99 33 505 8:15 AM 8:30 AM 4 53 32 55 0 12 48 10 1 43 80 4 1 23 113 28 5078:30 AM 8:45 AM 6 31 33 45 0 6 36 11 2 30 74 6 2 26 87 26 421 8:45 AM 9:00 AM 5 45 32 44 0 12 26 6 2 35 76 7 2 20 81 28 421 44 319 297 427 0 90 274 67 8 321 610 51 12 225 840 271 3856 7:15 AM 8:15 AM 25 157 172 235 0 47 132 32 3 176 312 27 6 135 453 161 2073 7:15 AM 8:15 AM 25 157 172 235 0 47 132 32 3 176 312 27 6 135 453 161 2073 Count Taken:2/8/2024 Buildout year:2031Growth Rate:3.8%1.0% PSCF:1.00 PHF 0.97 Adjusted PHF 0.95 ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr 2/8/2024 25 157 172 235 0 47 132 32 3 176 312 27 6 135 453 161 PSCF 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Adjusted Volumes 182 172 235 47 132 32 179 312 27 141 453 161 Growth Rate 3.8% 3.8% 3.8%3.8% 3.8% 3.8%3.8% 3.8% 3.8%3.8% 3.8% 3.8% 2031 Growth 63 60 82 16 46 11 62 108 9 49 157 56 Growth 3.8%245 232 317 63 178 43 241 420 36 190 610 217 Growth Rate 1.0% 1.0% 1.0%1.0% 1.0% 1.0%1.0% 1.0% 1.0%1.0% 1.0% 1.0% 2031 Growth 15 14 19 4 11 3 15 26 2 12 38 13 Growth 1%197 186 254 51 143 35 194 338 29 153 491 174Committed Projects Publix at Indrio AM IN 65 OUT 53 In/Out Out Out OUT In In In%0% 30% 15% 15% 0% 0% 15% 0% 0% 15% 0% 0% 0% 0% 0% 30% Volumes 0 16 8 8 0 0 10 0 0 10 0 0 0 0 0 20 Indrio Woods AM IN 26 OUT 89 In/Out In Out Out Out In In %0% 0% 18% 0% 0% 22% 18% 24% 0% 0% 0% 22% 0% 24% 0% 0% Volumes 0 0 5 0 0 20 16 21 0 0 0 6 0 6 0 0 Sabal Palm Grove AM IN 11 OUT 34 In/Out%0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Cabo Rio RV Resort AM IN 15 OUT 27In/Out In In Out Out Out In %45%15%45% 15% 15%15% Volumes 0 0 0 7 0 2 0 0 0 12 4 4 0 0 2 0Indrio & I-95 Development (25%)AM IN 270 OUT 267 In/Out Out Out Out In In In %0% 7% 7% 3% 0% 0% 7% 0% 0% 3% 0% 0% 0% 0% 0% 7% Volumes 0 19 19 8 0 0 19 0 0 8 0 0 0 0 0 19 Indrio Groves (25%)AM IN 95 OUT 275In/Out Out Out Out In In In %0% 1% 10% 15% 0% 0% 10% 0% 0% 15% 0% 0% 0% 0% 0% 1% Volumes 0 3 28 41 0 0 9 0 0 14 0 0 0 0 0 1Bedner Farms (25%)AM IN 83 OUT 130 In/Out Out Out Out In In In %0% 20% 13% 13% 0% 0% 13% 0% 0% 13% 0% 0% 0% 0% 0% 20%Volumes 0 26 17 17 0 0 11 0 0 11 0 0 0 0 0 17 Eagle Bend (25%)AM In 52 Out 158 In/Out % Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4540 N Kings Hwy (25%)AM IN 10 OUT 29 In/Out In In Out Out Out In %10%15%10% 35% 15%35%Volumes 0 0 0 1 0 2 0 0 0 3 10 4 0 0 4 0 Buc-ee's AM IN 610 OUT 570 In/Out Out Out Out In In In%1% 2% 1%2%1%1% Volumes 0 6 11 6 0 0 12 0 0 6 0 0 0 0 0 6 Indrio Townhomes (25%)AM IN 11 OUT 24In/Out In Out Out In in %28%16% 28%16%8% Volumes 0 0 3 0 0 4 7 0 0 0 0 2 0 1 0 0 Total Committed 0 69 90 88 0 27 84 21 0 64 14 16 0 7 6 62 Committed + 1%0 266 276 342 0 78 227 56 0 258 352 45 0 160 497 236 Weighted T-factor 6.1% 5.7% 6.2%6.4% 6.2% 6.1%10.5% 11.0% 9.3%4.1% 4.1% 4.0% Growth 3.8% or Committed + 1%266 276 342 78 227 56 258 420 45 190 610 236 2031 Pre-Development 266 276 342 78 227 56 258 420 45 190 610 236 Project Volumes 14 22 49 0 8 0 17 0 0 0 0 5 Post-Development 280 298 391 78 235 56 275 420 45 190 610 241 % Trucks Out Out Out In In In 0% 8% 13% 29% 0% 0% 13% 0% 0% 29% 0% 0% 0% 0% 0% 8% ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr Existing 0 182 172 235 0 47 132 32 0 179 312 27 0 141 453 161 Pre-Development 0 266 276 342 0 78 227 56 0 258 420 45 0 190 610 236Post-Development 0 280 298 391 0 78 235 56 0 275 420 45 0 190 610 241 13.7%4.4% Peak Hour Traffic Volume Club at Indrio Creek EXHIBIT 1A Kings Highway Indrio Rd Peak Hour Traffic Volume Assignment Maximum Peak Hour Traffic Volume 7.5%9.0% Page 211 of 456 HCM 7th Signalized Intersection Summary 2025 Existing AM 1: Kings Hwy & Indrio Rd 09/30/2025 Club at Indrio Creek 2025 Existing AM 12:29 pm 09/22/2025 Baseline Synchro 12 Report MEP Page 1 Movement EBL EBT EBR WBL WBT WBR NBL NBT NBR SBL SBT SBR Lane Configurations Traffic Volume (veh/h) 182 172 235 47 132 32 179 312 27 141 453 161 Future Volume (veh/h) 182 172 235 47 132 32 179 312 27 141 453 161 Initial Q (Qb), veh 0 0 0 0 0 0 0 0 0 0 0 0 Lane Width Adj. 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Ped-Bike Adj(A_pbT) 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Parking Bus, Adj 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Work Zone On Approach No No No No Adj Sat Flow, veh/h/ln 1796 1811 1796 1796 1796 1796 1722 1722 1722 1826 1826 1841 Adj Flow Rate, veh/h 192 181 105 49 139 13 188 328 12 148 477 64 Peak Hour Factor 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 Percent Heavy Veh, % 7 6 7 7 7 7 12 12 12 5 5 4 Cap, veh/h 493 916 405 384 663 296 268 797 356 251 812 365 Arrive On Green 0.12 0.27 0.27 0.05 0.19 0.19 0.08 0.24 0.24 0.07 0.23 0.23 Sat Flow, veh/h 1711 3441 1522 1711 3413 1522 3182 3272 1459 3374 3469 1560 Grp Volume(v), veh/h 192 181 105 49 139 13 188 328 12 148 477 64 Grp Sat Flow(s),veh/h/ln 1711 1721 1522 1711 1706 1522 1591 1636 1459 1687 1735 1560 Q Serve(g_s), s 6.6 3.1 4.2 1.7 2.6 0.5 4.4 6.5 0.5 3.3 9.4 2.5 Cycle Q Clear(g_c), s 6.6 3.1 4.2 1.7 2.6 0.5 4.4 6.5 0.5 3.3 9.4 2.5 Prop In Lane 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Lane Grp Cap(c), veh/h 493 916 405 384 663 296 268 797 356 251 812 365 V/C Ratio(X)0.39 0.20 0.26 0.13 0.21 0.04 0.70 0.41 0.03 0.59 0.59 0.18 Avail Cap(c_a), veh/h 790 1912 846 804 1989 887 330 2076 926 349 2201 990 HCM Platoon Ratio 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Upstream Filter(I) 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Uniform Delay (d), s/veh 20.0 21.9 22.3 22.7 26.1 25.3 34.4 24.5 22.3 34.6 26.3 23.6 Incr Delay (d2), s/veh 1.1 0.2 0.7 0.3 0.3 0.1 8.1 0.7 0.1 4.6 1.5 0.5 Initial Q Delay(d3), s/veh 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 %ile BackOfQ(95%),veh/ln 4.7 2.2 2.6 1.2 1.9 0.3 3.4 4.2 0.3 2.5 6.6 1.6 Unsig. Movement Delay, s/veh LnGrp Delay(d), s/veh 21.1 22.2 23.0 23.0 26.5 25.4 42.5 25.3 22.4 39.2 27.7 24.1 LnGrp LOS C C C C C C D C C D C C Approach Vol, veh/h 478 201 528 689 Approach Delay, s/veh 21.9 25.5 31.3 29.9 Approach LOS C C C C Timer - Assigned Phs 1 2 3 4 5 6 7 8 Phs Duration (G+Y+Rc), s16.6 22.1 12.7 25.8 11.0 27.7 13.5 25.1 Change Period (Y+Rc), s 7.1 7.1 7.0 7.0 7.1 7.1 7.0 7.0 Max Green Setting (Gmax), s22.9 45.0 8.0 49.0 22.9 42.9 8.0 49.0 Max Q Clear Time (g_c+I1), s8.6 4.6 5.3 8.5 3.7 6.2 6.4 11.4 Green Ext Time (p_c), s 1.0 1.8 0.2 4.1 0.2 3.1 0.2 6.6 Intersection Summary HCM 7th Control Delay, s/veh 27.8 HCM 7th LOS C Page 212 of 456 HCM 7th Signalized Intersection Summary 2031 Pre-Dev AM 1: Kings Hwy & Indrio Rd 09/30/2025 Club at Indrio Creek 2031 Pre-Dev AM 12:29 pm 09/22/2025 Baseline Synchro 12 Report MEP Page 1 Movement EBL EBT EBR WBL WBT WBR NBL NBT NBR SBL SBT SBR Lane Configurations Traffic Volume (veh/h) 266 276 342 78 227 56 258 420 45 190 610 236 Future Volume (veh/h) 266 276 342 78 227 56 258 420 45 190 610 236 Initial Q (Qb), veh 0 0 0 0 0 0 0 0 0 0 0 0 Lane Width Adj. 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Ped-Bike Adj(A_pbT) 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Parking Bus, Adj 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Work Zone On Approach No No No No Adj Sat Flow, veh/h/ln 1796 1811 1796 1796 1796 1796 1722 1722 1722 1826 1826 1841 Adj Flow Rate, veh/h 280 291 44 82 239 17 272 442 10 200 642 37 Peak Hour Factor 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 Percent Heavy Veh, % 7 6 7 7 7 7 12 12 12 5 5 4 Cap, veh/h 424 843 373 338 554 247 365 1002 447 292 965 434 Arrive On Green 0.14 0.24 0.24 0.06 0.16 0.16 0.11 0.31 0.31 0.09 0.28 0.28 Sat Flow, veh/h 1711 3441 1522 1711 3413 1522 3182 3272 1459 3374 3469 1560 Grp Volume(v), veh/h 280 291 44 82 239 17 272 442 10 200 642 37 Grp Sat Flow(s),veh/h/ln 1711 1721 1522 1711 1706 1522 1591 1636 1459 1687 1735 1560 Q Serve(g_s), s 12.2 6.4 2.1 3.6 5.8 0.9 7.6 10.0 0.4 5.3 15.1 1.6 Cycle Q Clear(g_c), s 12.2 6.4 2.1 3.6 5.8 0.9 7.6 10.0 0.4 5.3 15.1 1.6 Prop In Lane 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Lane Grp Cap(c), veh/h 424 843 373 338 554 247 365 1002 447 292 965 434 V/C Ratio(X)0.66 0.35 0.12 0.24 0.43 0.07 0.75 0.44 0.02 0.68 0.66 0.09 Avail Cap(c_a), veh/h 424 1996 883 357 1736 774 551 1771 790 548 1840 827 HCM Platoon Ratio 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Upstream Filter(I) 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Uniform Delay (d), s/veh 25.7 28.8 27.1 29.6 34.9 32.8 39.6 25.7 22.4 41.0 29.5 24.6 Incr Delay (d2), s/veh 5.1 0.5 0.3 0.8 1.1 0.2 6.4 0.7 0.0 5.9 1.7 0.2 Initial Q Delay(d3), s/veh 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 %ile BackOfQ(95%),veh/ln 9.2 4.8 1.3 2.8 4.4 0.6 5.6 6.6 0.3 4.2 10.0 1.0 Unsig. Movement Delay, s/veh LnGrp Delay(d), s/veh 30.8 29.3 27.4 30.4 36.0 33.0 46.0 26.4 22.4 46.9 31.2 24.8 LnGrp LOS C C C C D C D C C D C C Approach Vol, veh/h 615 338 724 879 Approach Delay, s/veh 29.9 34.5 33.7 34.5 Approach LOS C C C C Timer - Assigned Phs 1 2 3 4 5 6 7 8 Phs Duration (G+Y+Rc), s20.0 22.1 15.0 35.3 12.4 29.7 17.6 32.7 Change Period (Y+Rc), s 7.1 7.1 7.0 7.0 7.1 7.1 7.0 7.0 Max Green Setting (Gmax), s12.9 47.0 15.0 50.0 6.3 53.6 16.0 49.0 Max Q Clear Time (g_c+I1), s14.2 7.8 7.3 12.0 5.6 8.4 9.6 17.1 Green Ext Time (p_c), s 0.0 3.2 0.7 5.7 0.0 4.3 1.0 8.6 Intersection Summary HCM 7th Control Delay, s/veh 33.2 HCM 7th LOS C Page 213 of 456 HCM 7th Signalized Intersection Summary 2031 Post-Dev AM 1: Kings Hwy & Indrio Rd 09/30/2025 Club at Indrio Creek 2031 Post-Dev AM 12:29 pm 09/22/2025 Baseline Synchro 12 Report MEP Page 1 Movement EBL EBT EBR WBL WBT WBR NBL NBT NBR SBL SBT SBR Lane Configurations Traffic Volume (veh/h) 280 298 391 78 235 56 275 420 45 190 610 241 Future Volume (veh/h) 280 298 391 78 235 56 275 420 45 190 610 241 Initial Q (Qb), veh 0 0 0 0 0 0 0 0 0 0 0 0 Lane Width Adj. 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Ped-Bike Adj(A_pbT) 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Parking Bus, Adj 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Work Zone On Approach No No No No Adj Sat Flow, veh/h/ln 1796 1811 1796 1796 1796 1796 1722 1722 1722 1826 1826 1841 Adj Flow Rate, veh/h 295 314 96 82 247 17 289 442 10 200 642 43 Peak Hour Factor 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 Percent Heavy Veh, % 7 6 7 7 7 7 12 12 12 5 5 4 Cap, veh/h 417 836 370 325 550 245 381 1018 454 292 964 434 Arrive On Green 0.14 0.24 0.24 0.06 0.16 0.16 0.12 0.31 0.31 0.09 0.28 0.28 Sat Flow, veh/h 1711 3441 1522 1711 3413 1522 3182 3272 1459 3374 3469 1560 Grp Volume(v), veh/h 295 314 96 82 247 17 289 442 10 200 642 43 Grp Sat Flow(s),veh/h/ln 1711 1721 1522 1711 1706 1522 1591 1636 1459 1687 1735 1560 Q Serve(g_s), s 12.9 7.1 4.7 3.7 6.1 0.9 8.2 10.0 0.4 5.4 15.3 1.9 Cycle Q Clear(g_c), s 12.9 7.1 4.7 3.7 6.1 0.9 8.2 10.0 0.4 5.4 15.3 1.9 Prop In Lane 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Lane Grp Cap(c), veh/h 417 836 370 325 550 245 381 1018 454 292 964 434 V/C Ratio(X)0.71 0.38 0.26 0.25 0.45 0.07 0.76 0.43 0.02 0.69 0.67 0.10 Avail Cap(c_a), veh/h 417 1981 876 344 1722 768 547 1757 784 543 1825 821 HCM Platoon Ratio 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Upstream Filter(I) 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Uniform Delay (d), s/veh 26.6 29.4 28.5 29.9 35.3 33.1 39.7 25.5 22.2 41.3 29.8 25.0 Incr Delay (d2), s/veh 6.8 0.6 0.8 0.9 1.2 0.3 6.9 0.6 0.0 6.0 1.7 0.2 Initial Q Delay(d3), s/veh 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 %ile BackOfQ(95%),veh/ln 9.9 5.3 3.1 2.9 4.7 0.6 6.1 6.6 0.3 4.2 10.1 1.2 Unsig. Movement Delay, s/veh LnGrp Delay(d), s/veh 33.4 30.0 29.3 30.8 36.6 33.4 46.6 26.2 22.3 47.3 31.5 25.2 LnGrp LOS C C C C D C D C C D C C Approach Vol, veh/h 705 346 741 885 Approach Delay, s/veh 31.3 35.0 34.1 34.8 Approach LOS C D C C Timer - Assigned Phs 1 2 3 4 5 6 7 8 Phs Duration (G+Y+Rc), s20.0 22.1 15.0 36.0 12.4 29.7 18.1 32.9 Change Period (Y+Rc), s 7.1 7.1 7.0 7.0 7.1 7.1 7.0 7.0 Max Green Setting (Gmax), s12.9 47.0 15.0 50.0 6.3 53.6 16.0 49.0 Max Q Clear Time (g_c+I1), s14.9 8.1 7.4 12.0 5.7 9.1 10.2 17.3 Green Ext Time (p_c), s 0.0 3.6 0.7 5.7 0.0 5.1 1.0 8.6 Intersection Summary HCM 7th Control Delay, s/veh 33.7 HCM 7th LOS C Page 214 of 456 PM PEAK HOUR TURNING MOVEMENTS & Count Taken:2/7/2024 ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr totals 4:00 PM 4:15 PM 4 58 29 25 2 18 60 21 2 59 73 11 0 16 60 28 466 4:15 PM 4:30 PM 9 41 38 49 0 18 61 26 3 69 97 11 1 10 99 36 568 4:30 PM 4:45 PM 8 36 40 35 1 8 45 28 2 68 109 13 2 17 101 38 551 4:45 PM 5:00 PM 7 48 48 35 3 16 65 34 5 90 112 13 3 22 73 53 627 5:00 PM 5:15 PM 5 59 46 43 0 12 71 34 0 74 118 18 2 15 77 45 619 5:15 PM 5:30 PM 5 38 45 46 2 10 56 33 3 84 101 17 1 24 85 50 6005:30 PM 5:45 PM 4 49 25 51 0 17 77 24 1 81 116 17 1 17 77 36 593 5:45 PM 6:00 PM 11 37 36 44 3 10 53 25 2 55 88 9 5 24 82 22 506 53 366 307 328 11 109 488 225 18 580 814 109 15 145 654 308 4530 4:45 PM 5:45 PM 21 194 164 175 5 55 269 125 9 329 447 65 7 78 312 184 2439 Count Taken:2/8/2024 ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr totals 4:00 PM 4:15 PM 7 39 41 47 1 13 44 24 2 54 94 6 3 22 99 36 532 4:15 PM 4:30 PM 2 49 54 38 2 17 72 29 0 65 100 11 1 17 72 45 574 4:30 PM 4:45 PM 5 54 64 37 5 15 69 20 1 70 92 14 5 17 70 38 5764:45 PM 5:00 PM 5 57 40 33 3 16 68 21 2 98 128 27 2 29 85 53 667 5:00 PM 5:15 PM 5 56 41 48 3 23 46 26 2 66 103 10 2 14 84 37 566 5:15 PM 5:30 PM 5 63 52 46 4 23 94 37 2 64 109 11 1 18 86 38 6535:30 PM 5:45 PM 5 41 36 43 2 16 56 17 1 68 96 12 2 34 84 42 555 5:45 PM 6:00 PM 6 47 34 27 2 17 54 22 2 66 98 11 4 17 77 36 520 40 406 362 319 22 140 503 196 12 551 820 102 20 168 657 325 4643 4:30 PM 5:30 PM 20 230 197 164 15 77 277 104 7 298 432 62 10 78 325 166 2462 4:30 PM 5:30 PM 20 230 197 164 15 77 277 104 7 298 432 62 10 78 325 166 2462 Count Taken:2/8/2024 Buildout year:2031Growth Rate:3.8%1.0% PSCF:1.00 PHF 0.92 Adjusted PHF 0.92 ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr 2/8/2024 20 230 197 164 15 77 277 104 7 298 432 62 10 78 325 166 PSCF 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Adjusted Volumes 250 197 164 92 277 104 305 432 62 88 325 166 Growth Rate 3.8% 3.8% 3.8%3.8% 3.8% 3.8%3.8% 3.8% 3.8%3.8% 3.8% 3.8% 2031 Growth 87 68 57 32 96 36 106 150 22 31 113 58 Growth 3.8%337 265 221 124 373 140 411 582 84 119 438 224 Growth Rate 1.0% 1.0% 1.0%1.0% 1.0% 1.0%1.0% 1.0% 1.0%1.0% 1.0% 1.0% 2031 Growth 21 16 14 8 23 9 25 36 5 7 27 14 Growth 1%271 213 178 100 300 113 330 468 67 95 352 180Committed Projects Publix at Indrio PM IN 136 OUT 142 In/Out Out Out OUT In In In%0% 30% 15% 15% 0% 0% 15% 0% 0% 15% 0% 0% 0% 0% 0% 30% Volumes 0 43 21 21 0 0 20 0 0 20 0 0 0 0 0 41 Indrio Woods PM IN 69 OUT 44 In/Out In Out Out Out In In %0% 0% 18% 0% 0% 22% 18% 24% 0% 0% 0% 22% 0% 24% 0% 0% Volumes 0 0 12 0 0 10 8 11 0 0 0 15 0 17 0 0 Sabal Palm Grove PM IN 32 OUT 22 In/Out%0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Cabo Rio RV Resort PM IN 36 OUT 19In/Out In In Out Out Out In %45%15%45% 15% 15%15% Volumes 0 0 0 16 0 5 0 0 0 9 3 3 0 0 5 0Indrio & I-95 Development (25%)PM IN 373 OUT 386 In/Out Out Out Out In In In %0% 7% 7% 3% 0% 0% 7% 0% 0% 3% 0% 0% 0% 0% 0% 7% Volumes 0 27 27 12 0 0 26 0 0 11 0 0 0 0 0 26 Indrio Groves (25%)PM IN 95 OUT 197In/Out Out Out Out In In In %0% 1% 10% 15% 0% 0% 10% 0% 0% 15% 0% 0% 0% 0% 0% 1% Volumes 0 2 20 29 0 0 9 0 0 14 0 0 0 0 0 1Bedner Farms (25%)PM IN 204 OUT 173 In/Out Out Out Out In In In %0% 20% 13% 13% 0% 0% 13% 0% 0% 13% 0% 0% 0% 0% 0% 20%Volumes 0 35 22 22 0 0 27 0 0 27 0 0 0 0 0 41 Eagle Bend (25%)PM In 185 Out 109 In/Out % Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4540 N Kings Hwy (25%)PM IN 32 OUT 19 In/Out In In Out Out Out In %10%15%10% 35% 15%35%Volumes 0 0 0 3 0 5 0 0 0 2 6 3 0 0 11 0 Buc-ee's PM IN 772 OUT 786 In/Out Out Out Out In In In%1% 2% 1%2%1%1% Volumes 0 8 16 8 0 0 15 0 0 8 0 0 0 0 0 8 Indrio Townhomes (25%)PM IN 23 OUT 18In/Out In Out Out In in %28%16% 28%16%8% Volumes 0 0 7 0 0 3 5 0 0 0 0 4 0 2 0 0 Total Committed 0 114 125 112 0 23 111 11 0 90 9 25 0 18 16 116 Committed + 1%0 385 338 290 0 123 411 124 0 420 477 92 0 113 368 296 Weighted T-factor 4.4% 4.0% 3.9%4.1% 3.8% 4.0%3.5% 3.3% 3.3%3.9% 3.8% 3.2% Growth 3.8% or Committed + 1%385 338 290 124 411 140 420 582 92 119 438 296 2031 Pre-Development 385 338 290 124 411 140 420 582 92 119 438 296 Project Volumes 9 14 32 0 24 0 53 0 0 0 0 15 Post-Development 394 352 322 124 435 140 473 582 92 119 438 311 % Trucks Out Out Out In In In 0% 8% 13% 29% 0% 0% 13% 0% 0% 29% 0% 0% 0% 0% 0% 8% ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr Existing 0 250 197 164 0 92 277 104 0 305 432 62 0 88 325 166 Pre-Development 0 385 338 290 0 124 411 140 0 420 582 92 0 119 438 296Post-Development 0 394 352 322 0 124 435 140 0 473 582 92 0 119 438 311 5.2%4.2%3.4%4.0% Club at Indrio Creek EXHIBIT 1B Kings Highway Indrio Rd Peak Hour Traffic Volume Peak Hour Traffic Volume Assignment Maximum Peak Hour Traffic Volume Page 215 of 456 HCM 7th Signalized Intersection Summary 2025 Existing PM 1: Kings Hwy & Indrio Rd 09/30/2025 Club at Indrio Creek 2025 Existing PM 12:29 pm 09/22/2025 Baseline Synchro 12 Report MEP Page 1 Movement EBL EBT EBR WBL WBT WBR NBL NBT NBR SBL SBT SBR Lane Configurations Traffic Volume (veh/h) 250 197 164 92 277 104 305 432 62 88 325 166 Future Volume (veh/h) 250 197 164 92 277 104 305 432 62 88 325 166 Initial Q (Qb), veh 0 0 0 0 0 0 0 0 0 0 0 0 Lane Width Adj. 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Ped-Bike Adj(A_pbT) 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Parking Bus, Adj 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Work Zone On Approach No No No No Adj Sat Flow, veh/h/ln 1826 1841 1841 1826 1841 1841 1841 1841 1841 1841 1841 1841 Adj Flow Rate, veh/h 272 214 31 100 301 91 332 470 51 96 353 44 Peak Hour Factor 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 Percent Heavy Veh, % 5 4 4 5 4 4 4 4 4 4 4 4 Cap, veh/h 461 954 425 407 643 287 478 875 390 222 612 273 Arrive On Green 0.15 0.27 0.27 0.07 0.18 0.18 0.14 0.25 0.25 0.07 0.17 0.17 Sat Flow, veh/h 1739 3497 1560 1739 3497 1560 3401 3497 1560 3401 3497 1560 Grp Volume(v), veh/h 272 214 31 100 301 91 332 470 51 96 353 44 Grp Sat Flow(s),veh/h/ln 1739 1749 1560 1739 1749 1560 1700 1749 1560 1700 1749 1560 Q Serve(g_s), s 9.6 3.9 1.2 3.7 6.3 4.1 7.6 9.5 2.1 2.2 7.6 2.0 Cycle Q Clear(g_c), s 9.6 3.9 1.2 3.7 6.3 4.1 7.6 9.5 2.1 2.2 7.6 2.0 Prop In Lane 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Lane Grp Cap(c), veh/h 461 954 425 407 643 287 478 875 390 222 612 273 V/C Ratio(X)0.59 0.22 0.07 0.25 0.47 0.32 0.69 0.54 0.13 0.43 0.58 0.16 Avail Cap(c_a), veh/h 595 2544 1135 431 2012 897 918 2659 1186 375 2102 937 HCM Platoon Ratio 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Upstream Filter(I) 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Uniform Delay (d), s/veh 20.2 23.0 22.0 24.3 29.7 28.8 33.4 26.5 23.7 36.7 30.9 28.6 Incr Delay (d2), s/veh 2.6 0.3 0.2 0.7 1.1 1.3 3.8 1.1 0.3 2.8 1.8 0.6 Initial Q Delay(d3), s/veh 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 %ile BackOfQ(95%),veh/ln 7.1 2.8 0.8 2.8 4.7 2.7 5.6 6.7 1.3 1.7 5.5 1.3 Unsig. Movement Delay, s/veh LnGrp Delay(d), s/veh 22.7 23.2 22.2 25.0 30.8 30.2 37.2 27.6 24.0 39.5 32.7 29.1 LnGrp LOS C C C C C C D C C D C C Approach Vol, veh/h 517 492 853 493 Approach Delay, s/veh 22.9 29.5 31.1 33.7 Approach LOS C C C C Timer - Assigned Phs 1 2 3 4 5 6 7 8 Phs Duration (G+Y+Rc), s19.7 22.1 12.3 27.4 12.5 29.3 18.5 21.3 Change Period (Y+Rc), s 7.1 7.1 7.0 7.0 7.1 7.1 7.0 7.0 Max Green Setting (Gmax), s18.9 46.9 9.0 62.0 6.5 59.3 22.0 49.0 Max Q Clear Time (g_c+I1), s11.6 8.3 4.2 11.5 5.7 5.9 9.6 9.6 Green Ext Time (p_c), s 1.0 4.7 0.2 6.7 0.0 3.1 1.9 4.7 Intersection Summary HCM 7th Control Delay, s/veh 29.5 HCM 7th LOS C Page 216 of 456 HCM 7th Signalized Intersection Summary 2031 Pre-Dev PM 1: Kings Hwy & Indrio Rd 09/30/2025 Club at Indrio Creek 2031 Pre-Dev PM 12:29 pm 09/22/2025 Baseline Synchro 12 Report MEP Page 1 Movement EBL EBT EBR WBL WBT WBR NBL NBT NBR SBL SBT SBR Lane Configurations Traffic Volume (veh/h) 385 338 290 124 411 140 420 582 92 119 438 296 Future Volume (veh/h) 385 338 290 124 411 140 420 582 92 119 438 296 Initial Q (Qb), veh 0 0 0 0 0 0 0 0 0 0 0 0 Lane Width Adj. 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Ped-Bike Adj(A_pbT) 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Parking Bus, Adj 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Work Zone On Approach No No No No Adj Sat Flow, veh/h/ln 1826 1841 1841 1826 1841 1841 1841 1841 1841 1841 1841 1841 Adj Flow Rate, veh/h 418 367 70 135 447 16 457 633 13 129 476 50 Peak Hour Factor 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 Percent Heavy Veh, % 5 4 4 5 4 4 4 4 4 4 4 4 Cap, veh/h 462 1057 471 380 668 298 547 1069 477 193 704 314 Arrive On Green 0.19 0.30 0.30 0.08 0.19 0.19 0.16 0.31 0.31 0.06 0.20 0.20 Sat Flow, veh/h 1739 3497 1560 1739 3497 1560 3401 3497 1560 3401 3497 1560 Grp Volume(v), veh/h 418 367 70 135 447 16 457 633 13 129 476 50 Grp Sat Flow(s),veh/h/ln 1739 1749 1560 1739 1749 1560 1700 1749 1560 1700 1749 1560 Q Serve(g_s), s 20.9 9.0 3.6 6.8 13.0 0.9 14.3 16.9 0.6 4.1 13.8 2.9 Cycle Q Clear(g_c), s 20.9 9.0 3.6 6.8 13.0 0.9 14.3 16.9 0.6 4.1 13.8 2.9 Prop In Lane 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Lane Grp Cap(c), veh/h 462 1057 471 380 668 298 547 1069 477 193 704 314 V/C Ratio(X)0.91 0.35 0.15 0.36 0.67 0.05 0.83 0.59 0.03 0.67 0.68 0.16 Avail Cap(c_a), veh/h 462 1820 812 395 1461 652 650 1878 837 340 1559 696 HCM Platoon Ratio 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Upstream Filter(I) 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Uniform Delay (d), s/veh 27.9 29.9 28.0 31.8 41.2 36.3 44.7 32.4 26.7 50.8 40.6 36.2 Incr Delay (d2), s/veh 22.0 0.4 0.3 1.2 2.5 0.2 10.0 1.1 0.0 8.2 2.4 0.5 Initial Q Delay(d3), s/veh 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 %ile BackOfQ(95%),veh/ln16.7 6.8 2.4 5.3 9.7 0.6 10.7 11.2 0.4 3.4 9.9 2.0 Unsig. Movement Delay, s/veh LnGrp Delay(d), s/veh 49.9 30.3 28.3 33.0 43.7 36.5 54.7 33.5 26.8 59.0 43.0 36.7 LnGrp LOS D C C C D D D C C E D D Approach Vol, veh/h 855 598 1103 655 Approach Delay, s/veh 39.7 41.1 42.2 45.7 Approach LOS D D D D Timer - Assigned Phs 1 2 3 4 5 6 7 8 Phs Duration (G+Y+Rc), s28.0 28.1 13.2 40.6 15.8 40.3 24.7 29.1 Change Period (Y+Rc), s 7.1 7.1 7.0 7.0 7.1 7.1 7.0 7.0 Max Green Setting (Gmax), s20.9 45.9 11.0 59.0 9.6 57.2 21.0 49.0 Max Q Clear Time (g_c+I1), s22.9 15.0 6.1 18.9 8.8 11.0 16.3 15.8 Green Ext Time (p_c), s 0.0 5.9 0.3 8.7 0.1 5.7 1.4 6.3 Intersection Summary HCM 7th Control Delay, s/veh 42.0 HCM 7th LOS D Page 217 of 456 HCM 7th Signalized Intersection Summary 2031 Post-Dev PM 1: Kings Hwy & Indrio Rd 09/30/2025 Club at Indrio Creek 2031 Post-Dev PM 12:29 pm 09/22/2025 Baseline Synchro 12 Report MEP Page 1 Movement EBL EBT EBR WBL WBT WBR NBL NBT NBR SBL SBT SBR Lane Configurations Traffic Volume (veh/h) 394 352 322 124 435 140 473 582 92 119 438 311 Future Volume (veh/h) 394 352 322 124 435 140 473 582 92 119 438 311 Initial Q (Qb), veh 0 0 0 0 0 0 0 0 0 0 0 0 Lane Width Adj. 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Ped-Bike Adj(A_pbT) 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Parking Bus, Adj 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Work Zone On Approach No No No No Adj Sat Flow, veh/h/ln 1826 1841 1841 1826 1841 1841 1841 1841 1841 1841 1841 1841 Adj Flow Rate, veh/h 428 383 51 135 473 16 514 633 13 129 476 66 Peak Hour Factor 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 Percent Heavy Veh, % 5 4 4 5 4 4 4 4 4 4 4 4 Cap, veh/h 459 1094 488 379 692 309 599 1111 496 189 689 307 Arrive On Green 0.19 0.31 0.31 0.08 0.20 0.20 0.18 0.32 0.32 0.06 0.20 0.20 Sat Flow, veh/h 1739 3497 1560 1739 3497 1560 3401 3497 1560 3401 3497 1560 Grp Volume(v), veh/h 428 383 51 135 473 16 514 633 13 129 476 66 Grp Sat Flow(s),veh/h/ln 1739 1749 1560 1739 1749 1560 1700 1749 1560 1700 1749 1560 Q Serve(g_s), s 22.9 10.1 2.8 7.3 14.9 1.0 17.5 18.0 0.7 4.4 15.1 4.2 Cycle Q Clear(g_c), s 22.9 10.1 2.8 7.3 14.9 1.0 17.5 18.0 0.7 4.4 15.1 4.2 Prop In Lane 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Lane Grp Cap(c), veh/h 459 1094 488 379 692 309 599 1111 496 189 689 307 V/C Ratio(X)0.93 0.35 0.10 0.36 0.68 0.05 0.86 0.57 0.03 0.68 0.69 0.21 Avail Cap(c_a), veh/h 459 1729 771 389 1348 601 685 1820 812 314 1439 642 HCM Platoon Ratio 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Upstream Filter(I) 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Uniform Delay (d), s/veh 30.0 31.6 29.1 33.9 44.3 38.7 47.6 33.9 28.0 55.2 44.5 40.1 Incr Delay (d2), s/veh 26.8 0.4 0.2 1.2 2.6 0.1 11.2 1.0 0.0 9.0 2.7 0.7 Initial Q Delay(d3), s/veh 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 %ile BackOfQ(95%),veh/ln18.6 7.7 1.8 5.8 11.0 0.7 12.7 11.9 0.5 3.7 10.7 2.9 Unsig. Movement Delay, s/veh LnGrp Delay(d), s/veh 56.8 32.0 29.3 35.1 46.9 38.9 58.9 34.8 28.0 64.2 47.1 40.8 LnGrp LOS E C C D D D E C C E D D Approach Vol, veh/h 862 624 1160 671 Approach Delay, s/veh 44.1 44.1 45.4 49.8 Approach LOS D D D D Timer - Assigned Phs 1 2 3 4 5 6 7 8 Phs Duration (G+Y+Rc), s30.0 30.7 13.6 44.8 16.3 44.4 28.0 30.5 Change Period (Y+Rc), s 7.1 7.1 7.0 7.0 7.1 7.1 7.0 7.0 Max Green Setting (Gmax), s22.9 45.9 11.0 62.0 9.9 58.9 24.0 49.0 Max Q Clear Time (g_c+I1), s24.9 16.9 6.4 20.0 9.3 12.1 19.5 17.1 Green Ext Time (p_c), s 0.0 6.6 0.3 8.8 0.0 5.8 1.5 6.4 Intersection Summary HCM 7th Control Delay, s/veh 45.7 HCM 7th LOS D Page 218 of 456 AM PEAK HOUR TURNING MOVEMENTS & Count Taken:9/23/2025 ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr totals 7:00 AM 7:15 AM 0 0 103 0 0 0 103 0 0 1 0 0 0 0 0 0 207 7:15 AM 7:30 AM 0 0 124 1 0 0 94 0 0 1 0 0 0 0 0 0 220 7:30 AM 7:45 AM 0 0 140 0 0 0 99 0 0 0 0 0 0 0 0 0 239 7:45 AM 8:00 AM 0 0 160 1 0 0 92 0 0 3 0 0 0 0 0 0 256 8:00 AM 8:15 AM 0 0 147 2 0 0 102 0 0 1 0 1 0 0 0 0 253 8:15 AM 8:30 AM 0 0 105 2 0 0 85 0 0 0 0 0 0 0 0 0 192 8:30 AM 8:45 AM 0 0 106 2 0 1 77 0 0 1 0 0 0 0 0 0 187 8:45 AM 9:00 AM 0 0 115 1 0 4 84 0 0 2 0 3 0 0 0 0 209 0 0 1000 9 0 5 736 0 0 9 0 4 0 0 0 0 1763 7:15 AM 8:15 AM 0 0 571 4 0 0 387 0 0 5 0 1 0 0 0 0 968 Count Taken:9/23/2025 Buildout year:2031 Growth Rate:3.8%1.0% PSCF:1.09 PHF 0.95 Adjusted PHF 0.95 ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr 9/23/2025 0 0 571 4 0 0 387 0 0 5 0 1 0 0 0 0 PSCF 0 0 51 0 0 0 35 0 0 0 0 0 0 0 0 0 Adjusted Volumes 0 622 4 0 422 0 5 0 1 0 0 0 Growth Rate 3.8% 3.8% 3.8%3.8% 3.8% 3.8%3.8% 3.8% 3.8%3.8% 3.8% 3.8% 2031 Growth 0 186 1 0 126 0 1 0 0 0 0 0 Growth 3.8%0 808 5 0 548 0 6 0 1 0 0 0 Growth Rate 1.0% 1.0% 1.0%1.0% 1.0% 1.0%1.0% 1.0% 1.0%1.0% 1.0% 1.0% 2031 Growth 0 45 0 0 30 0 0 0 0 0 0 0 Growth 1%0 667 4 0 452 0 5 0 1 0 0 0 Committed Projects Publix at Indrio AM IN 65 OUT 53In/Out Out In %0% 0% 65% 0% 0% 0% 65% 0% 0% 0% 0% 0% 0% 0% 0% 0% Volumes 0 0 34 0 0 0 42 0 0 0 0 0 0 0 0 0 Indrio Woods AM IN 26 OUT 89 In/Out %0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Sabal Palm Grove AM IN 11 OUT 34 In/Out out in %0% 0% 45% 0% 0% 0% 23% 0% 0% 0% 0% 0% 0% 0% 0% 0% Volumes 0 0 15 0 0 0 3 0 0 0 0 0 0 0 0 0 Cabo Rio RV Resort AM IN 15 OUT 27 In/Out In Out %0% 0% 45% 0% 0% 0% 45% 0% 0% 0% 0% 0% 0% 0% 0% 0% Volumes 0 0 7 0 0 0 12 0 0 0 0 0 0 0 0 0 Indrio & I-95 Development (25%)AM IN 270 OUT 267 In/Out Out In %0% 0% 20% 0% 0% 0% 20% 0% 0% 0% 0% 0% 0% 0% 0% 0% Volumes 0 0 53 0 0 0 54 0 0 0 0 0 0 0 0 0 Indrio Groves (25%)AM IN 95 OUT 275 In/Out Out In %0% 0% 26% 0% 0% 0% 26% 0% 0% 0% 0% 0% 0% 0% 0% 0% Volumes 0 0 72 0 0 0 25 0 0 0 0 0 0 0 0 0 Bedner Farms (25%)AM IN 83 OUT 130 In/Out Out In %0% 0% 46% 0% 0% 0% 46% 0% 0% 0% 0% 0% 0% 0% 0% 0% Volumes 0 0 60 0 0 0 38 0 0 0 0 0 0 0 0 0 Eagle Bend (25%)AM In 52 Out 158 In/Out % Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4540 N Kings Hwy (25%)AM IN 10 OUT 29 In/Out in Out %9%9% Volumes 0 0 1 0 0 0 3 0 0 0 0 0 0 0 0 0 Buc-ee's AM IN 610 OUT 570 In/Out Out In %5%5% Volumes 0 0 29 0 0 0 31 0 0 0 0 0 0 0 0 0Indrio Townhomes (25%)4 8 Total Committed 0 0 274 0 0 0 215 0 0 0 0 0 0 0 0 0Committed + 1%0 0 941 4 0 0 667 0 0 5 0 1 0 0 0 0 Weighted T-factor 3.2% 3.4%3.1%3.6%4.3% Growth 3.8% or Committed + 1%0 941 5 0 667 0 6 0 1 0 0 0 2031 Pre-Development 0 941 5 0 667 0 6 0 1 0 0 0 Project Volumes 0 95 0 0 34 0 0 0 0 0 0 0 Post-Development 0 1036 5 0 701 0 6 0 1 0 0 0 % Trucks Out In 0% 0% 56% 0% 0% 0% 56% 0% 0% 0% 0% 0% 0% 0% 0% 0% ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbrExisting 0 0 622 4 0 0 422 0 0 5 0 1 0 0 0 0 Pre-Development 0 0 941 5 0 0 667 0 0 6 0 1 0 0 0 0 Post-Development 0 0 1036 5 0 0 701 0 0 6 0 1 0 0 0 0 Club at Indrio Creek EXHIBIT 1C Seminole Road Indrio Rd Peak Hour Traffic Volume 3.3%6.2%16.7%0.0% Assignment Page 219 of 456 HCM 7th TWSC 2025 Existing AM 2: Seminole Rd & Indrio Rd 09/30/2025 Club at Indrio Creek 2025 Existing AM 12:29 pm 09/22/2025 Baseline Synchro 12 Report MEP Page 1 Intersection Int Delay, s/veh 0.1 Movement EBT EBR WBL WBT NBL NBR Lane Configurations Traffic Vol, veh/h 622 4 0 422 5 1 Future Vol, veh/h 622 4 0 422 5 1 Conflicting Peds, #/hr 0 0 0 0 0 0 Sign Control Free Free Free Free Stop Stop RT Channelized - None - None - None Storage Length - - - - - - Veh in Median Storage, #0 - - 0 0 - Grade, %0 - - 0 0 - Peak Hour Factor 95 95 95 95 95 95 Heavy Vehicles, % 4 4 4 4 4 4 Mvmt Flow 655 4 0 444 5 1 Major/Minor Major1 Major2 Minor1 Conflicting Flow All 0 0 659 0 1101 657 Stage 1 - - - - 657 - Stage 2 - - - - 444 - Critical Hdwy - - 4.14 - 6.44 6.24 Critical Hdwy Stg 1 - - - - 5.44 - Critical Hdwy Stg 2 - - - - 5.44 - Follow-up Hdwy - -2.236 -3.5363.336 Pot Cap-1 Maneuver - - 920 - 232 461 Stage 1 - - - - 512 - Stage 2 - - - - 642 - Platoon blocked, % - - - Mov Cap-1 Maneuver - - 920 - 232 461 Mov Cap-2 Maneuver - - - - 232 - Stage 1 - - - - 512 - Stage 2 - - - - 642 - Approach EB WB NB HCM Control Delay, s/v0 0 19.57 HCM LOS C Minor Lane/Major MvmtNBLn1 EBT EBR WBL WBT Capacity (veh/h) 253 - - 920 - HCM Lane V/C Ratio 0.025 - - - - HCM Control Delay (s/veh)19.6 - - 0 - HCM Lane LOS C - - A - HCM 95th %tile Q(veh) 0.1 - - 0 - Page 220 of 456 HCM 7th TWSC 2031 Pre-Dev AM 2: Seminole Rd & Indrio Rd 09/30/2025 Club at Indrio Creek 2031 Pre-Dev AM 12:29 pm 09/22/2025 Baseline Synchro 12 Report MEP Page 1 Intersection Int Delay, s/veh 0.2 Movement EBT EBR WBL WBT NBL NBR Lane Configurations Traffic Vol, veh/h 941 5 0 667 6 1 Future Vol, veh/h 941 5 0 667 6 1 Conflicting Peds, #/hr 0 0 0 0 0 0 Sign Control Free Free Free Free Stop Stop RT Channelized - None - None - None Storage Length - - - - - - Veh in Median Storage, #0 - - 0 0 - Grade, %0 - - 0 0 - Peak Hour Factor 95 95 95 95 95 95 Heavy Vehicles, % 4 4 4 4 4 4 Mvmt Flow 991 5 0 702 6 1 Major/Minor Major1 Major2 Minor1 Conflicting Flow All 0 0 996 0 1695 993 Stage 1 - - - - 993 - Stage 2 - - - - 702 - Critical Hdwy - - 4.14 - 6.44 6.24 Critical Hdwy Stg 1 - - - - 5.44 - Critical Hdwy Stg 2 - - - - 5.44 - Follow-up Hdwy - -2.236 -3.5363.336 Pot Cap-1 Maneuver - - 687 - 101 295 Stage 1 - - - - 355 - Stage 2 - - - - 488 - Platoon blocked, % - - - Mov Cap-1 Maneuver - - 687 - 101 295 Mov Cap-2 Maneuver - - - - 101 - Stage 1 - - - - 355 - Stage 2 - - - - 488 - Approach EB WB NB HCM Control Delay, s/v0 0 39.65 HCM LOS E Minor Lane/Major MvmtNBLn1 EBT EBR WBL WBT Capacity (veh/h) 111 - - 687 - HCM Lane V/C Ratio 0.066 - - - - HCM Control Delay (s/veh)39.7 - - 0 - HCM Lane LOS E - - A - HCM 95th %tile Q(veh) 0.2 - - 0 - Page 221 of 456 HCM 7th TWSC 2031 Post-Dev AM 2: Seminole Rd & Indrio Rd 09/30/2025 Club at Indrio Creek 2031 Post-Dev AM 12:29 pm 09/22/2025 Baseline Synchro 12 Report MEP Page 1 Intersection Int Delay, s/veh 0.2 Movement EBT EBR WBL WBT NBL NBR Lane Configurations Traffic Vol, veh/h 1036 5 0 701 6 1 Future Vol, veh/h 1036 5 0 701 6 1 Conflicting Peds, #/hr 0 0 0 0 0 0 Sign Control Free Free Free Free Stop Stop RT Channelized - None - None - None Storage Length - - - - - - Veh in Median Storage, #0 - - 0 0 - Grade, %0 - - 0 0 - Peak Hour Factor 95 95 95 95 95 95 Heavy Vehicles, % 4 4 4 4 4 4 Mvmt Flow 1091 5 0 738 6 1 Major/Minor Major1 Major2 Minor1 Conflicting Flow All 0 0 1096 0 1831 1093 Stage 1 - - - - 1093 - Stage 2 - - - - 738 - Critical Hdwy - - 4.14 - 6.44 6.24 Critical Hdwy Stg 1 - - - - 5.44 - Critical Hdwy Stg 2 - - - - 5.44 - Follow-up Hdwy - -2.236 -3.5363.336 Pot Cap-1 Maneuver - - 629 - 83 258 Stage 1 - - - - 318 - Stage 2 - - - - 469 - Platoon blocked, % - - - Mov Cap-1 Maneuver - - 629 - 83 258 Mov Cap-2 Maneuver - - - - 83 - Stage 1 - - - - 318 - Stage 2 - - - - 469 - Approach EB WB NB HCM Control Delay, s/v0 0 47.59 HCM LOS E Minor Lane/Major MvmtNBLn1 EBT EBR WBL WBT Capacity (veh/h) 92 - - 629 - HCM Lane V/C Ratio 0.08 - - - - HCM Control Delay (s/veh)47.6 - - 0 - HCM Lane LOS E - - A - HCM 95th %tile Q(veh) 0.3 - - 0 - Page 222 of 456 PM PEAK HOUR TURNING MOVEMENTS & Count Taken:9/23/2025 ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr totals 4:00 PM 4:15 PM 0 0 102 0 0 0 86 0 0 2 0 1 0 0 0 0 191 4:15 PM 4:30 PM 0 0 95 1 0 2 152 0 0 2 0 1 0 0 0 0 253 4:30 PM 4:45 PM 0 0 117 0 0 1 139 0 0 2 0 2 0 0 0 0 261 4:45 PM 5:00 PM 0 0 130 0 0 1 142 0 0 1 0 2 0 0 0 0 276 5:00 PM 5:15 PM 0 0 129 1 0 0 160 0 0 0 0 1 0 0 0 0 291 5:15 PM 5:30 PM 0 0 164 0 0 2 189 0 0 1 0 2 0 0 0 0 358 5:30 PM 5:45 PM 0 0 109 2 0 0 130 0 0 2 0 1 0 0 0 0 244 5:45 PM 6:00 PM 0 0 84 1 0 1 134 0 0 0 0 0 0 0 0 0 220 0 0 930 5 0 7 1132 0 0 10 0 10 0 0 0 0 2094 4:30 PM 5:30 PM 0 0 540 1 0 4 630 0 0 4 0 7 0 0 0 0 1186 Count Taken:9/23/2025 Buildout year:2031 Growth Rate:3.8%1.0% PSCF:1.09 PHF 0.83 Adjusted PHF 0.92 ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr 9/23/2025 0 0 540 1 0 4 630 0 0 4 0 7 0 0 0 0 PSCF 0 0 49 0 0 0 57 0 0 0 0 1 0 0 0 0 Adjusted Volumes 0 589 1 4 687 0 4 0 8 0 0 0 Growth Rate 3.8% 3.8% 3.8%3.8% 3.8% 3.8%3.8% 3.8% 3.8%3.8% 3.8% 3.8% 2031 Growth 0 176 0 1 205 0 1 0 2 0 0 0 Growth 3.8%0 765 1 5 892 0 5 0 10 0 0 0 Growth Rate 1.0% 1.0% 1.0%1.0% 1.0% 1.0%1.0% 1.0% 1.0%1.0% 1.0% 1.0% 2031 Growth 0 42 0 0 50 0 0 0 1 0 0 0 Growth 1%0 631 1 4 737 0 4 0 9 0 0 0 Committed Projects Publix at Indrio PM IN 136 OUT 142In/Out Out In %0% 0% 65% 0% 0% 0% 65% 0% 0% 0% 0% 0% 0% 0% 0% 0% Volumes 0 0 92 0 0 0 88 0 0 0 0 0 0 0 0 0 Indrio Woods PM IN 69 OUT 44 In/Out %0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Sabal Palm Grove PM IN 32 OUT 22 In/Out out in %0% 0% 45% 0% 0% 0% 23% 0% 0% 0% 0% 0% 0% 0% 0% 0% Volumes 0 0 10 0 0 0 7 0 0 0 0 0 0 0 0 0 Cabo Rio RV Resort PM IN 36 OUT 19 In/Out In Out %0% 0% 45% 0% 0% 0% 45% 0% 0% 0% 0% 0% 0% 0% 0% 0% Volumes 0 0 16 0 0 0 9 0 0 0 0 0 0 0 0 0 Indrio & I-95 Development (25%)PM IN 373 OUT 386 In/Out Out In %0% 0% 20% 0% 0% 0% 20% 0% 0% 0% 0% 0% 0% 0% 0% 0% Volumes 0 0 77 0 0 0 75 0 0 0 0 0 0 0 0 0 Indrio Groves (25%)PM IN 335 OUT 197 In/Out Out In %0% 0% 26% 0% 0% 0% 26% 0% 0% 0% 0% 0% 0% 0% 0% 0% Volumes 0 0 51 0 0 0 87 0 0 0 0 0 0 0 0 0 Bedner Farms (25%)PM IN 204 OUT 173 In/Out Out In %0% 0% 46% 0% 0% 0% 46% 0% 0% 0% 0% 0% 0% 0% 0% 0% Volumes 0 0 79 0 0 0 94 0 0 0 0 0 0 0 0 0 Eagle Bend (25%)PM In 185 Out 109 In/Out % Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4540 N Kings Hwy (25%)PM IN 32 OUT 19 In/Out in Out %9%9% Volumes 0 0 3 0 0 0 2 0 0 0 0 0 0 0 0 0 Buc-ee's PM IN 772 OUT 786 In/Out Out In %5%5% Volumes 0 0 39 0 0 0 39 0 0 0 0 0 0 0 0 0Indrio Townhomes (25%)8 5 Total Committed 0 0 376 0 0 0 405 0 0 0 0 0 0 0 0 0Committed + 1%0 0 1007 1 0 4 1142 0 0 4 0 9 0 0 0 0 Weighted T-factor 3.6% 5.4%3.6%4.3%4.4% Growth 3.8% or Committed + 1%0 1007 1 5 1142 0 5 0 10 0 0 0 2031 Pre-Development 0 1007 1 5 1142 0 5 0 10 0 0 0 Project Volumes 0 62 0 0 102 0 0 0 0 0 0 0 Post-Development 0 1069 1 5 1244 0 5 0 10 0 0 0 % Trucks Out In 0% 0% 56% 0% 0% 0% 56% 0% 0% 0% 0% 0% 0% 0% 0% 0% ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbrExisting 0 0 589 1 0 4 687 0 0 4 0 8 0 0 0 0 Pre-Development 0 0 1007 1 0 5 1142 0 0 5 0 10 0 0 0 0 Post-Development 0 0 1069 1 0 5 1244 0 0 5 0 10 0 0 0 0 Club at Indrio Creek EXHIBIT 1D Seminole Road Indrio Rd Peak Hour Traffic Volume 4.4%2.1%0.0%0.0% Assignment Page 223 of 456 HCM 7th TWSC 2025 Existing PM 2: Seminole Rd & Indrio Rd 09/30/2025 Club at Indrio Creek 2025 Existing PM 12:29 pm 09/22/2025 Baseline Synchro 12 Report MEP Page 1 Intersection Int Delay, s/veh 0.2 Movement EBT EBR WBL WBT NBL NBR Lane Configurations Traffic Vol, veh/h 589 1 4 687 4 8 Future Vol, veh/h 589 1 4 687 4 8 Conflicting Peds, #/hr 0 0 0 0 0 0 Sign Control Free Free Free Free Stop Stop RT Channelized - None - None - None Storage Length - - - - - - Veh in Median Storage, #0 - - 0 0 - Grade, %0 - - 0 0 - Peak Hour Factor 92 92 92 92 92 92 Heavy Vehicles, % 4 6 4 4 4 4 Mvmt Flow 640 1 4 747 4 9 Major/Minor Major1 Major2 Minor1 Conflicting Flow All 0 0 641 0 1396 641 Stage 1 - - - - 641 - Stage 2 - - - - 755 - Critical Hdwy - - 4.14 - 6.44 6.24 Critical Hdwy Stg 1 - - - - 5.44 - Critical Hdwy Stg 2 - - - - 5.44 - Follow-up Hdwy - -2.236 -3.5363.336 Pot Cap-1 Maneuver - - 934 - 154 471 Stage 1 - - - - 521 - Stage 2 - - - - 461 - Platoon blocked, % - - - Mov Cap-1 Maneuver - - 934 - 153 471 Mov Cap-2 Maneuver - - - - 153 - Stage 1 - - - - 521 - Stage 2 - - - - 457 - Approach EB WB NB HCM Control Delay, s/v0 0.05 18.59 HCM LOS C Minor Lane/Major MvmtNBLn1 EBT EBR WBL WBT Capacity (veh/h) 278 - - 10 - HCM Lane V/C Ratio 0.047 - -0.005 - HCM Control Delay (s/veh)18.6 - - 8.9 0 HCM Lane LOS C - - A A HCM 95th %tile Q(veh) 0.1 - - 0 - Page 224 of 456 HCM 7th TWSC 2031 Pre-Dev PM 2: Seminole Rd & Indrio Rd 09/30/2025 Club at Indrio Creek 2031 Pre-Dev PM 12:29 pm 09/22/2025 Baseline Synchro 12 Report MEP Page 1 Intersection Int Delay, s/veh 0.4 Movement EBT EBR WBL WBT NBL NBR Lane Configurations Traffic Vol, veh/h 1007 1 5 1142 5 10 Future Vol, veh/h 1007 1 5 1142 5 10 Conflicting Peds, #/hr 0 0 0 0 0 0 Sign Control Free Free Free Free Stop Stop RT Channelized - None - None - None Storage Length - - - - - - Veh in Median Storage, #0 - - 0 0 - Grade, %0 - - 0 0 - Peak Hour Factor 92 92 92 92 92 92 Heavy Vehicles, % 4 6 4 4 4 4 Mvmt Flow 1095 1 5 1241 5 11 Major/Minor Major1 Major2 Minor1 Conflicting Flow All 0 0 1096 0 2347 1095 Stage 1 - - - - 1095 - Stage 2 - - - - 1252 - Critical Hdwy - - 4.14 - 6.44 6.24 Critical Hdwy Stg 1 - - - - 5.44 - Critical Hdwy Stg 2 - - - - 5.44 - Follow-up Hdwy - -2.236 -3.5363.336 Pot Cap-1 Maneuver - - 630 - 39 257 Stage 1 - - - - 318 - Stage 2 - - - - 267 - Platoon blocked, % - - - Mov Cap-1 Maneuver - - 630 - 38 257 Mov Cap-2 Maneuver - - - - 38 - Stage 1 - - - - 318 - Stage 2 - - - - 259 - Approach EB WB NB HCM Control Delay, s/v0 0.05 54.92 HCM LOS F Minor Lane/Major MvmtNBLn1 EBT EBR WBL WBT Capacity (veh/h) 88 - - 8 - HCM Lane V/C Ratio 0.185 - -0.009 - HCM Control Delay (s/veh)54.9 - - 10.8 0 HCM Lane LOS F - - B A HCM 95th %tile Q(veh) 0.6 - - 0 - Page 225 of 456 HCM 7th TWSC 2031 Post-Dev PM 2: Seminole Rd & Indrio Rd 09/30/2025 Club at Indrio Creek 2031 Post-Dev PM 12:29 pm 09/22/2025 Baseline Synchro 12 Report MEP Page 1 Intersection Int Delay, s/veh 0.5 Movement EBT EBR WBL WBT NBL NBR Lane Configurations Traffic Vol, veh/h 1069 1 5 1244 5 10 Future Vol, veh/h 1069 1 5 1244 5 10 Conflicting Peds, #/hr 0 0 0 0 0 0 Sign Control Free Free Free Free Stop Stop RT Channelized - None - None - None Storage Length - - - - - - Veh in Median Storage, #0 - - 0 0 - Grade, %0 - - 0 0 - Peak Hour Factor 92 92 92 92 92 92 Heavy Vehicles, % 4 6 4 4 4 4 Mvmt Flow 1162 1 5 1352 5 11 Major/Minor Major1 Major2 Minor1 Conflicting Flow All 0 0 1163 0 2526 1163 Stage 1 - - - - 1163 - Stage 2 - - - - 1363 - Critical Hdwy - - 4.14 - 6.44 6.24 Critical Hdwy Stg 1 - - - - 5.44 - Critical Hdwy Stg 2 - - - - 5.44 - Follow-up Hdwy - -2.236 -3.5363.336 Pot Cap-1 Maneuver - - 594 - 30 235 Stage 1 - - - - 295 - Stage 2 - - - - 236 - Platoon blocked, % - - - Mov Cap-1 Maneuver - - 594 - 29 235 Mov Cap-2 Maneuver - - - - 29 - Stage 1 - - - - 295 - Stage 2 - - - - 227 - Approach EB WB NB HCM Control Delay, s/v0 0.04 71.74 HCM LOS F Minor Lane/Major MvmtNBLn1 EBT EBR WBL WBT Capacity (veh/h) 70 - - 7 - HCM Lane V/C Ratio 0.234 - -0.009 - HCM Control Delay (s/veh)71.7 - - 11.1 0 HCM Lane LOS F - - B A HCM 95th %tile Q(veh) 0.8 - - 0 - Page 226 of 456 AM PEAK HOUR TURNING MOVEMENTS & Count Taken:2/7/2024 ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr totals 7:00 AM 7:15 AM 0 18 48 0 0 0 67 27 0 0 0 0 0 41 0 48 249 7:15 AM 7:30 AM 0 25 68 0 0 0 52 23 0 0 1 0 0 42 0 74 285 7:30 AM 7:45 AM 0 30 101 0 0 0 106 22 0 0 0 0 0 41 0 55 355 7:45 AM 8:00 AM 0 41 74 0 1 0 86 29 0 0 0 0 0 45 0 42 318 8:00 AM 8:15 AM 0 37 78 1 0 0 65 26 0 0 0 0 0 34 0 45 286 8:15 AM 8:30 AM 0 46 78 0 0 0 68 29 0 0 0 0 0 39 0 43 3038:30 AM 8:45 AM 0 24 75 1 0 0 58 26 0 0 0 1 0 32 0 39 256 8:45 AM 9:00 AM 0 37 64 0 0 0 51 21 0 0 0 1 0 31 0 46 251 0 258 586 2 1 0 553 203 0 0 1 2 0 305 0 392 2303 7:30 AM 8:30 AM 0 154 331 1 1 0 325 106 0 0 0 0 0 159 0 185 1262 Count Taken:2/8/2024 ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr totals 7:00 AM 7:15 AM 0 22 62 0 0 0 81 21 0 0 0 1 0 30 0 41 258 7:15 AM 7:30 AM 0 38 67 0 0 0 103 20 0 0 0 0 0 45 0 66 339 7:30 AM 7:45 AM 0 43 87 2 0 0 116 26 0 0 0 1 0 51 0 67 3937:45 AM 8:00 AM 0 36 83 0 1 0 72 24 0 0 0 1 0 38 0 61 316 8:00 AM 8:15 AM 0 30 75 1 0 0 57 34 0 0 0 1 0 43 0 36 277 8:15 AM 8:30 AM 0 40 78 0 0 0 76 32 0 0 0 0 0 32 0 33 2918:30 AM 8:45 AM 1 23 62 0 0 0 54 24 0 0 0 0 0 18 1 44 227 8:45 AM 9:00 AM 0 29 105 0 1 0 49 20 0 0 0 0 0 31 0 33 268 1 261 619 3 2 0 608 201 0 0 0 4 0 288 1 381 2369 7:15 AM 8:15 AM 0 147 312 3 1 0 348 104 0 0 0 3 0 177 0 230 1325 7:15 AM 8:15 AM 0 147 312 3 1 0 348 104 0 0 0 3 0 177 0 230 1325 Count Taken:2/8/2024Buildout year:2031 Growth Rate:3.8%1.0% PSCF:1.00PHF0.84 Adjusted PHF 0.92 ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr 2/8/2024 0 147 312 3 1 0 348 104 0 0 0 3 0 177 0 230PSCF0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Adjusted Volumes 147 312 3 1 348 104 0 0 3 177 0 230 Growth Rate 3.8% 3.8% 3.8%3.8% 3.8% 3.8%3.8% 3.8% 3.8%3.8% 3.8% 3.8% 2031 Growth 51 108 1 0 121 36 0 0 1 62 0 80Growth 3.8%198 420 4 1 469 140 0 0 4 239 0 310 Growth Rate 1.0% 1.0% 1.0%1.0% 1.0% 1.0%1.0% 1.0% 1.0%1.0% 1.0% 1.0% 2031 Growth 12 26 0 0 29 9 0 0 0 15 0 19Growth 1%159 338 3 1 377 113 0 0 3 192 0 249 Committed Projects Publix at Indrio AM IN 65 OUT 53In/Out Out Out In In Out %0% 5% 20% 0% 0% 0% 60% 5% 0% 0% 0% 0% 0% 45% 0% 0% Volumes 0 3 11 0 0 0 39 3 0 0 0 0 0 24 0 0 Indrio Woods AM IN 26 OUT 89 In/Out %0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Sabal Palm Grove AM IN 11 OUT 34In/Out In In Out Out %0% 45% 0% 0% 0% 0% 0% 23% 0% 0% 0% 0% 0% 45% 0% 23% Volumes 0 5 0 0 0 0 0 3 0 0 0 0 0 15 0 8Cabo Rio RV Resort AM IN 15 OUT 27 In/Out In Out Out In %0% 0% 41% 0% 0% 0% 41% 4% 0% 0% 0% 0% 0% 4% 0% 0%Volumes 0 0 6 0 0 0 11 1 0 0 0 0 0 1 0 0 Indrio & I-95 Development (25%)AM IN 270 OUT 267 In/Out Out Out In In %0% 6% 20% 0% 0% 0% 20% 0% 0% 0% 0% 0% 0% 0% 0% 6% Volumes 0 16 53 0 0 0 54 0 0 0 0 0 0 0 0 16Indrio Groves (25%)AM IN 95 OUT 275 In/Out Out Out In In %0% 2% 26% 0% 0% 0% 26% 0% 0% 0% 0% 0% 0% 0% 0% 2%Volumes 0 6 72 0 0 0 25 0 0 0 0 0 0 0 0 2 Bedner Farms (25%)AM IN 83 OUT 130 In/Out Out Out In In%0% 5% 46% 0% 0% 0% 46% 0% 0% 0% 0% 0% 0% 0% 0% 5% Volumes 0 6 60 0 0 0 38 0 0 0 0 0 0 0 0 4 Eagle Bend (25%)AM In 52 Out 158 In/Out % Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4540 N Kings Hwy (25%)AM IN 10 OUT 29 In/Out in Out Out In%8%8% 1%1% Volumes 0 0 0 1 0 0 2 0 0 0 0 0 0 0 0 0 Buc-ee's AM IN 610 OUT 570In/Out Out Out In In %2% 5%5%2% Volumes 0 9 29 0 0 0 31 0 0 0 0 0 0 0 0 9Indrio Townhomes (25%)3 6 2 1 Total Committed 0 44 233 1 0 0 206 9 0 0 0 0 0 41 0 39 Committed + 1%0 203 571 4 0 1 583 122 0 0 0 3 0 233 0 288 Weighted T-Factor 7.4% 5.9% 7.6%9.9% 6.3% 7.5%7.4%7.6%7.5% Growth 3.8% or Committed + 1%203 571 4 1 583 140 0 0 4 239 0 310 2031 Pre-Development 203 571 4 1 583 140 0 0 4 239 0 310 Project Volumes 0 0 18 34 0 0 51 24 95 0 8 0 Post-Development 203 571 22 35 583 140 51 24 99 239 8 310 % Trucks In In Out Out Out In 0% 0% 0% 30% 0% 56% 0% 0% 0% 30% 14% 56% 0% 0% 14% 0% ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr Existing 0 147 312 3 0 1 348 104 0 0 0 3 0 177 0 230Pre-Development 0 203 571 4 0 1 583 140 0 0 0 4 0 239 0 310 Post-Development 0 203 571 22 0 35 583 140 0 51 24 99 0 239 8 310 0.0%4.7% Peak Hour Traffic Volume Club at Indrio Creek EXHIBIT 1E Emerson Avenue Indrio Rd Peak Hour Traffic Volume Assignment Maximum Peak Hour Traffic Volume 8.9%7.3% Page 227 of 456 HCM 7th Signalized Intersection Summary 2025 Existing AM 3: Emerson Ave & Indrio Rd 09/30/2025 Club at Indrio Creek 2025 Existing AM 12:29 pm 09/22/2025 Baseline Synchro 12 Report MEP Page 2 Movement EBL EBT EBR WBL WBT WBR NBL NBT NBR SBL SBT SBR Lane Configurations Traffic Volume (veh/h) 147 312 3 1 348 104 0 0 3 177 0 230 Future Volume (veh/h) 147 312 3 1 348 104 0 0 3 177 0 230 Initial Q (Qb), veh 0 0 0 0 0 0 0 0 0 0 0 0 Lane Width Adj. 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Ped-Bike Adj(A_pbT) 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Parking Bus, Adj 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Work Zone On Approach No No No No Adj Sat Flow, veh/h/ln 1781 1811 1781 1752 1796 1781 1796 1796 1796 1781 1781 1781 Adj Flow Rate, veh/h 160 339 0 1 378 21 0 0 0 192 0 60 Peak Hour Factor 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 Percent Heavy Veh, % 8 6 8 10 7 8 7 7 7 8 8 8 Cap, veh/h 420 1092 479 3 655 290 7 4 0 675 0 986 Arrive On Green 0.13 0.32 0.00 0.00 0.19 0.19 0.00 0.00 0.00 0.20 0.00 0.20 Sat Flow, veh/h 3291 3441 1510 1668 3413 1510 3421 1796 0 3393 0 3019 Grp Volume(v), veh/h 160 339 0 1 378 21 0 0 0 192 0 60 Grp Sat Flow(s),veh/h/ln 1646 1721 1510 1668 1706 1510 1711 1796 0 1697 0 1510 Q Serve(g_s), s 2.2 3.6 0.0 0.0 4.9 0.6 0.0 0.0 0.0 2.3 0.0 0.7 Cycle Q Clear(g_c), s 2.2 3.6 0.0 0.0 4.9 0.6 0.0 0.0 0.0 2.3 0.0 0.7 Prop In Lane 1.00 1.00 1.00 1.00 1.00 0.00 1.00 1.00 Lane Grp Cap(c), veh/h 420 1092 479 3 655 290 7 4 0 675 0 986 V/C Ratio(X)0.38 0.31 0.00 0.29 0.58 0.07 0.00 0.00 0.00 0.28 0.00 0.06 Avail Cap(c_a), veh/h 1775 4618 2026 282 3316 1467 1916 1006 0 3178 0 3213 HCM Platoon Ratio 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Upstream Filter(I) 1.00 1.00 0.00 1.00 1.00 1.00 0.00 0.00 0.00 1.00 0.00 1.00 Uniform Delay (d), s/veh 19.4 12.6 0.0 24.2 17.8 16.1 0.0 0.0 0.0 16.5 0.0 11.2 Incr Delay (d2), s/veh 0.6 0.2 0.0 41.2 0.8 0.1 0.0 0.0 0.0 0.2 0.0 0.0 Initial Q Delay(d3), s/veh 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 %ile BackOfQ(95%),veh/ln 1.3 2.0 0.0 0.1 2.9 0.3 0.0 0.0 0.0 1.4 0.0 0.3 Unsig. Movement Delay, s/veh LnGrp Delay(d), s/veh 20.0 12.7 0.0 65.4 18.6 16.2 0.0 0.0 0.0 16.8 0.0 11.3 LnGrp LOS C B E B B B B Approach Vol, veh/h 499 400 0 252 Approach Delay, s/veh 15.1 18.6 0.0 15.4 Approach LOS B B B Timer - Assigned Phs 2 3 4 6 7 8 Phs Duration (G+Y+Rc), s 17.5 14.0 17.1 0.0 7.9 23.2 Change Period (Y+Rc), s 7.8 7.8 7.8 7.8 7.8 7.8 Max Green Setting (Gmax), s 45.5 26.2 47.2 27.2 8.2 65.2 Max Q Clear Time (g_c+I1), s 4.3 4.2 6.9 0.0 2.0 5.6 Green Ext Time (p_c), s 0.9 0.5 2.5 0.0 0.0 2.2 Intersection Summary HCM 7th Control Delay, s/veh 16.4 HCM 7th LOS B Notes User approved pedestrian interval to be less than phase max green. User approved volume balancing among the lanes for turning movement. Page 228 of 456 HCM 7th Signalized Intersection Summary 2031 Pre-Dev AM 3: Emerson Ave & Indrio Rd 09/30/2025 Club at Indrio Creek 2031 Pre-Dev AM 12:29 pm 09/22/2025 Baseline Synchro 12 Report MEP Page 2 Movement EBL EBT EBR WBL WBT WBR NBL NBT NBR SBL SBT SBR Lane Configurations Traffic Volume (veh/h) 203 571 4 1 583 140 0 0 4 239 0 310 Future Volume (veh/h) 203 571 4 1 583 140 0 0 4 239 0 310 Initial Q (Qb), veh 0 0 0 0 0 0 0 0 0 0 0 0 Lane Width Adj. 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Ped-Bike Adj(A_pbT) 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Parking Bus, Adj 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Work Zone On Approach No No No No Adj Sat Flow, veh/h/ln 1781 1811 1781 1752 1796 1781 1796 1796 1796 1781 1781 1781 Adj Flow Rate, veh/h 221 621 0 1 634 22 0 0 2 260 0 38 Peak Hour Factor 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 Percent Heavy Veh, % 8 6 8 10 7 8 7 7 7 8 8 8 Cap, veh/h 344 1265 555 3 905 400 9 0 8 513 0 772 Arrive On Green 0.10 0.37 0.00 0.00 0.27 0.27 0.00 0.00 0.01 0.15 0.00 0.15 Sat Flow, veh/h 3291 3441 1510 1668 3413 1510 1711 0 1522 3393 0 3019 Grp Volume(v), veh/h 221 621 0 1 634 22 0 0 2 260 0 38 Grp Sat Flow(s),veh/h/ln 1646 1721 1510 1668 1706 1510 1711 0 1522 1697 0 1510 Q Serve(g_s), s 4.2 9.2 0.0 0.0 11.0 0.7 0.0 0.0 0.1 4.6 0.0 0.6 Cycle Q Clear(g_c), s 4.2 9.2 0.0 0.0 11.0 0.7 0.0 0.0 0.1 4.6 0.0 0.6 Prop In Lane 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Lane Grp Cap(c), veh/h 344 1265 555 3 905 400 9 0 8 513 0 772 V/C Ratio(X)0.64 0.49 0.00 0.31 0.70 0.05 0.00 0.00 0.24 0.51 0.00 0.05 Avail Cap(c_a), veh/h 1209 3511 1540 182 2601 1151 707 0 629 2293 0 2356 HCM Platoon Ratio 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Upstream Filter(I) 1.00 1.00 0.00 1.00 1.00 1.00 0.00 0.00 1.00 1.00 0.00 1.00 Uniform Delay (d), s/veh 28.3 16.1 0.0 32.8 21.8 18.0 0.0 0.0 32.6 25.7 0.0 18.5 Incr Delay (d2), s/veh 2.0 0.3 0.0 47.4 1.0 0.1 0.0 0.0 14.3 0.8 0.0 0.0 Initial Q Delay(d3), s/veh 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 %ile BackOfQ(95%),veh/ln 2.9 5.5 0.0 0.1 7.1 0.4 0.0 0.0 0.1 3.1 0.0 0.4 Unsig. Movement Delay, s/veh LnGrp Delay(d), s/veh 30.3 16.4 0.0 80.2 22.8 18.1 0.0 0.0 46.9 26.5 0.0 18.5 LnGrp LOS C B F C B D C B Approach Vol, veh/h 842 657 2 298 Approach Delay, s/veh 20.0 22.8 46.9 25.5 Approach LOS C C D C Timer - Assigned Phs 2 3 4 6 7 8 Phs Duration (G+Y+Rc), s 17.8 14.7 25.3 8.2 7.9 32.0 Change Period (Y+Rc), s 7.8 7.8 7.8 7.8 7.8 7.8 Max Green Setting (Gmax), s 44.5 24.2 50.2 27.2 7.2 67.2 Max Q Clear Time (g_c+I1), s 6.6 6.2 13.0 2.1 2.0 11.2 Green Ext Time (p_c), s 1.0 0.6 4.4 0.0 0.0 4.3 Intersection Summary HCM 7th Control Delay, s/veh 22.0 HCM 7th LOS C Notes User approved pedestrian interval to be less than phase max green. User approved volume balancing among the lanes for turning movement. Page 229 of 456 HCM 7th Signalized Intersection Summary 2031 Post-Dev AM 3: Emerson Ave & Indrio Rd 09/30/2025 Club at Indrio Creek 2031 Post-Dev AM 12:29 pm 09/22/2025 Baseline Synchro 12 Report MEP Page 2 Movement EBL EBT EBR WBL WBT WBR NBL NBT NBR SBL SBT SBR Lane Configurations Traffic Volume (veh/h) 203 571 22 35 583 140 51 24 99 239 8 310 Future Volume (veh/h) 203 571 22 35 583 140 51 24 99 239 8 310 Initial Q (Qb), veh 0 0 0 0 0 0 0 0 0 0 0 0 Lane Width Adj. 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Ped-Bike Adj(A_pbT) 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Parking Bus, Adj 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Work Zone On Approach No No No No Adj Sat Flow, veh/h/ln 1781 1811 1781 1752 1796 1781 1796 1796 1796 1781 1781 1781 Adj Flow Rate, veh/h 221 621 13 38 634 22 54 28 26 266 0 38 Peak Hour Factor 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 Percent Heavy Veh, % 8 6 8 10 7 8 7 7 7 8 8 8 Cap, veh/h 323 1033 453 84 863 382 199 100 93 438 0 686 Arrive On Green 0.10 0.30 0.30 0.05 0.25 0.25 0.12 0.12 0.12 0.13 0.00 0.13 Sat Flow, veh/h 3291 3441 1510 1668 3413 1510 1711 857 796 3393 0 3019 Grp Volume(v), veh/h 221 621 13 38 634 22 54 0 54 266 0 38 Grp Sat Flow(s),veh/h/ln 1646 1721 1510 1668 1706 1510 1711 0 1653 1697 0 1510 Q Serve(g_s), s 5.0 11.9 0.5 1.7 13.2 0.9 2.2 0.0 2.3 5.7 0.0 0.8 Cycle Q Clear(g_c), s 5.0 11.9 0.5 1.7 13.2 0.9 2.2 0.0 2.3 5.7 0.0 0.8 Prop In Lane 1.00 1.00 1.00 1.00 1.00 0.48 1.00 1.00 Lane Grp Cap(c), veh/h 323 1033 453 84 863 382 199 0 193 438 0 686 V/C Ratio(X)0.68 0.60 0.03 0.45 0.73 0.06 0.27 0.00 0.28 0.61 0.00 0.06 Avail Cap(c_a), veh/h 1030 2723 1195 242 2127 941 624 0 603 1996 0 2073 HCM Platoon Ratio 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Upstream Filter(I) 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 1.00 0.00 1.00 Uniform Delay (d), s/veh 33.7 23.1 19.1 35.7 26.5 21.9 31.2 0.0 31.2 31.8 0.0 23.4 Incr Delay (d2), s/veh 2.6 0.6 0.0 3.7 1.2 0.1 0.7 0.0 0.8 1.4 0.0 0.0 Initial Q Delay(d3), s/veh 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 %ile BackOfQ(95%),veh/ln 3.6 7.9 0.3 1.3 8.7 0.5 1.6 0.0 1.6 4.1 0.0 0.5 Unsig. Movement Delay, s/veh LnGrp Delay(d), s/veh 36.3 23.7 19.1 39.4 27.8 22.0 31.9 0.0 32.0 33.2 0.0 23.4 LnGrp LOS D C B D C C C C C C Approach Vol, veh/h 855 694 108 304 Approach Delay, s/veh 26.9 28.2 31.9 32.0 Approach LOS C C C C Timer - Assigned Phs 2 3 4 6 7 8 Phs Duration (G+Y+Rc), s 17.8 15.4 27.3 16.8 11.7 31.0 Change Period (Y+Rc), s 7.8 7.8 7.8 7.8 7.8 7.8 Max Green Setting (Gmax), s 45.5 24.2 48.2 28.2 11.2 61.2 Max Q Clear Time (g_c+I1), s 7.7 7.0 15.2 4.3 3.7 13.9 Green Ext Time (p_c), s 1.1 0.6 4.4 0.4 0.0 4.4 Intersection Summary HCM 7th Control Delay, s/veh 28.4 HCM 7th LOS C Notes User approved pedestrian interval to be less than phase max green. User approved volume balancing among the lanes for turning movement. Page 230 of 456 PM PEAK HOUR TURNING MOVEMENTS & Count Taken:2/7/2024 ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr totals4:00 PM 4:15 PM 0 49 95 0 0 0 70 28 0 0 0 1 0 35 0 26 304 4:15 PM 4:30 PM 0 42 84 1 1 0 95 56 0 0 0 1 0 35 1 37 353 4:30 PM 4:45 PM 1 73 90 0 0 0 92 56 0 0 0 1 0 30 0 31 374 4:45 PM 5:00 PM 0 67 116 1 0 0 109 56 0 0 0 1 0 34 0 26 4105:00 PM 5:15 PM 0 54 103 2 0 0 108 52 0 0 1 0 0 33 0 26 379 5:15 PM 5:30 PM 0 77 101 0 0 0 99 59 0 0 0 0 0 40 0 25 401 5:30 PM 5:45 PM 0 84 90 0 2 0 103 55 0 0 1 1 0 30 0 22 388 5:45 PM 6:00 PM 0 63 72 0 0 1 80 46 0 0 0 1 0 33 0 24 3201 509 751 4 3 1 756 408 0 0 2 6 0 270 1 217 2929 4:45 PM 5:45 PM 0 282 410 3 2 0 419 222 0 0 2 2 0 137 0 99 1578 Count Taken:2/8/2024 ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr totals 4:00 PM 4:15 PM 0 60 90 0 0 0 84 25 0 0 0 1 0 27 0 27 314 4:15 PM 4:30 PM 0 67 97 0 0 1 114 39 0 0 0 0 0 35 0 29 3824:30 PM 4:45 PM 0 59 103 0 0 1 93 67 0 1 0 1 0 32 0 30 387 4:45 PM 5:00 PM 0 60 101 0 0 0 119 58 0 0 0 1 0 30 1 41 411 5:00 PM 5:15 PM 0 59 104 0 1 0 90 53 0 0 0 0 0 37 0 27 371 5:15 PM 5:30 PM 0 57 103 0 0 1 114 50 0 0 0 0 0 45 0 29 399 5:30 PM 5:45 PM 0 53 92 0 0 0 93 51 0 0 0 0 0 35 0 25 3495:45 PM 6:00 PM 0 50 76 0 0 0 80 50 0 0 0 0 0 26 0 17 299 0 465 766 0 1 3 787 393 0 1 0 3 0 267 1 225 2912 4:30 PM 5:30 PM 0 235 411 0 1 2 416 228 0 1 0 2 0 144 1 127 1568 4:45 PM 5:45 PM 0 282 410 3 2 0 419 222 0 0 2 2 0 137 0 99 1578 Count Taken:2/7/2024 Buildout year:2031 Growth Rate:3.8%1.0% PSCF:1.00PHF0.96 Adjusted PHF 0.95 ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr 2/7/2024 0 282 410 3 2 0 419 222 0 0 2 2 0 137 0 99 PSCF 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Adjusted Volumes 282 410 3 2 419 222 0 2 2 137 0 99 Growth Rate 3.8% 3.8% 3.8%3.8% 3.8% 3.8%3.8% 3.8% 3.8%3.8% 3.8% 3.8% 2031 Growth 98 143 1 1 146 77 0 1 1 48 0 34Growth 3.8%380 553 4 3 565 299 0 3 3 185 0 133 Growth Rate 1.0% 1.0% 1.0%1.0% 1.0% 1.0%1.0% 1.0% 1.0%1.0% 1.0% 1.0%2031 Growth 23 34 0 0 35 18 0 0 0 11 0 8 Growth 1%305 444 3 2 454 240 0 2 2 148 0 107 Committed Projects Publix at Indrio PM IN 136 OUT 142In/Out Out Out In In Out %0% 5% 20% 0% 0% 0% 60% 5% 0% 0% 0% 0% 0% 45% 0% 0% Volumes 0 7 28 0 0 0 82 7 0 0 0 0 0 64 0 0 Indrio Woods PM IN 69 OUT 44In/Out %0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Sabal Palm Grove PM IN 32 OUT 22In/Out In In Out Out %0% 45% 0% 0% 0% 0% 0% 23% 0% 0% 0% 0% 0% 45% 0% 23% Volumes 0 14 0 0 0 0 0 7 0 0 0 0 0 10 0 5 Cabo Rio RV Resort PM IN 36 OUT 19 In/Out In Out Out In%0% 0% 41% 0% 0% 0% 41% 4% 0% 0% 0% 0% 0% 4% 0% 0% Volumes 0 0 15 0 0 0 8 1 0 0 0 0 0 1 0 0 Indrio & I-95 Development (25%)PM IN 373 OUT 386 In/Out Out Out In In%0% 6% 20% 0% 0% 0% 20% 0% 0% 0% 0% 0% 0% 0% 0% 6% Volumes 0 23 77 0 0 0 75 0 0 0 0 0 0 0 0 22 Indrio Groves (25%)PM IN 335 OUT 197 In/Out Out Out In In%0% 2% 26% 0% 0% 0% 26% 0% 0% 0% 0% 0% 0% 0% 0% 2% Volumes 0 4 51 0 0 0 87 0 0 0 0 0 0 0 0 7 Bedner Farms (25%)PM IN 204 OUT 173 In/Out Out Out In In%0% 5% 46% 0% 0% 0% 46% 0% 0% 0% 0% 0% 0% 0% 0% 5% Volumes 0 9 79 0 0 0 94 0 0 0 0 0 0 0 0 10 Eagle Bend (25%)PM In 185 Out 109 In/Out% Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4540 N Kings Hwy (25%)PM IN 32 OUT 19 In/Out in Out Out In%8%8% 1%1% Volumes 0 0 0 3 0 0 1 0 0 0 0 0 0 0 0 0 Buc-ee's PM IN 772 OUT 786 In/Out Out Out In In %2% 5%5%2%Volumes 0 12 39 0 0 0 39 0 0 0 0 0 0 0 0 12 Indrio Townhomes (25%)6 4 1 2 Total Committed 0 69 296 3 0 0 389 16 0 0 0 0 0 78 0 56 Committed + 1%0 374 740 6 0 2 843 256 0 0 2 2 0 226 0 163 Weighted T-Factor 3.4% 2.8% 2.8%2.9% 2.6% 3.3%2.9%3.0%3.0% Growth 3.8% or Committed + 1%380 740 6 3 843 299 0 3 3 226 0 163 2031 Pre-Development 380 740 6 3 843 299 0 3 3 226 0 163 Project Volumes 0 0 55 102 0 0 33 16 62 0 25 0 Post-Development 380 740 61 105 843 299 33 19 65 226 25 163 % Trucks In In Out Out Out In 0% 0% 0% 30% 0% 56% 0% 0% 0% 30% 14% 56% 0% 0% 14% 0% ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr Existing 0 282 410 3 0 2 419 222 0 0 2 2 0 137 0 99Pre-Development 0 380 740 6 0 3 843 299 0 0 3 3 0 226 0 163 Post-Development 0 380 740 61 0 105 843 299 0 33 19 65 0 226 25 163 3.3%2.6%0.0%3.4% Club at Indrio Creek EXHIBIT 1F Emerson Avenue Indrio Rd Peak Hour Traffic Volume Peak Hour Traffic Volume Assignment Maximum Peak Hour Traffic Volume Page 231 of 456 HCM 7th Signalized Intersection Summary 2025 Existing PM 3: Emerson Ave & Indrio Rd 09/30/2025 Club at Indrio Creek 2025 Existing PM 12:29 pm 09/22/2025 Baseline Synchro 12 Report MEP Page 2 Movement EBL EBT EBR WBL WBT WBR NBL NBT NBR SBL SBT SBR Lane Configurations Traffic Volume (veh/h) 282 410 3 2 419 222 0 2 2 137 0 99 Future Volume (veh/h) 282 410 3 2 419 222 0 2 2 137 0 99 Initial Q (Qb), veh 0 0 0 0 0 0 0 0 0 0 0 0 Lane Width Adj. 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Ped-Bike Adj(A_pbT) 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Parking Bus, Adj 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Work Zone On Approach No No No No Adj Sat Flow, veh/h/ln 1841 1856 1856 1856 1856 1856 1856 1856 1856 1841 1841 1841 Adj Flow Rate, veh/h 297 432 0 2 441 50 0 2 0 144 0 25 Peak Hour Factor 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 Percent Heavy Veh, % 4 3 3 3 3 3 3 3 3 4 4 4 Cap, veh/h 444 1141 509 7 694 309 10 10 0 543 0 890 Arrive On Green 0.13 0.32 0.00 0.00 0.20 0.20 0.00 0.01 0.00 0.15 0.00 0.15 Sat Flow, veh/h 3401 3526 1572 1767 3526 1572 1767 1856 0 3506 0 3120 Grp Volume(v), veh/h 297 432 0 2 441 50 0 2 0 144 0 25 Grp Sat Flow(s),veh/h/ln 1700 1763 1572 1767 1763 1572 1767 1856 0 1753 0 1560 Q Serve(g_s), s 5.1 5.8 0.0 0.1 7.0 1.6 0.0 0.1 0.0 2.2 0.0 0.4 Cycle Q Clear(g_c), s 5.1 5.8 0.0 0.1 7.0 1.6 0.0 0.1 0.0 2.2 0.0 0.4 Prop In Lane 1.00 1.00 1.00 1.00 1.00 0.00 1.00 1.00 Lane Grp Cap(c), veh/h 444 1141 509 7 694 309 10 10 0 543 0 890 V/C Ratio(X)0.67 0.38 0.00 0.30 0.64 0.16 0.00 0.20 0.00 0.27 0.00 0.03 Avail Cap(c_a), veh/h 1575 3833 1710 238 2675 1193 789 829 0 2562 0 2687 HCM Platoon Ratio 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Upstream Filter(I) 1.00 1.00 0.00 1.00 1.00 1.00 0.00 1.00 0.00 1.00 0.00 1.00 Uniform Delay (d), s/veh 25.2 15.9 0.0 30.2 22.5 20.3 0.0 30.1 0.0 22.7 0.0 15.7 Incr Delay (d2), s/veh 1.7 0.2 0.0 22.6 1.0 0.2 0.0 9.2 0.0 0.3 0.0 0.0 Initial Q Delay(d3), s/veh 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 %ile BackOfQ(95%),veh/ln 3.5 3.5 0.0 0.1 4.7 1.0 0.0 0.1 0.0 1.5 0.0 0.2 Unsig. Movement Delay, s/veh LnGrp Delay(d), s/veh 27.0 16.1 0.0 52.8 23.4 20.5 0.0 39.3 0.0 22.9 0.0 15.7 LnGrp LOS C B D C C D C B Approach Vol, veh/h 729 493 2 169 Approach Delay, s/veh 20.5 23.3 39.3 21.9 Approach LOS C C D C Timer - Assigned Phs 2 3 4 6 7 8 Phs Duration (G+Y+Rc), s 17.2 15.8 19.8 8.1 8.0 27.5 Change Period (Y+Rc), s 7.8 7.8 7.8 7.8 7.8 7.8 Max Green Setting (Gmax), s 44.5 28.2 46.2 27.2 8.2 66.2 Max Q Clear Time (g_c+I1), s 4.2 7.1 9.0 2.1 2.1 7.8 Green Ext Time (p_c), s 0.6 0.9 3.0 0.0 0.0 2.8 Intersection Summary HCM 7th Control Delay, s/veh 21.7 HCM 7th LOS C Notes User approved pedestrian interval to be less than phase max green. User approved volume balancing among the lanes for turning movement. Page 232 of 456 HCM 7th Signalized Intersection Summary 2031 Pre-Dev PM 3: Emerson Ave & Indrio Rd 09/30/2025 Club at Indrio Creek 2031 Pre-Dev PM 12:29 pm 09/22/2025 Baseline Synchro 12 Report MEP Page 2 Movement EBL EBT EBR WBL WBT WBR NBL NBT NBR SBL SBT SBR Lane Configurations Traffic Volume (veh/h) 380 740 6 3 843 299 0 3 3 226 0 163 Future Volume (veh/h) 380 740 6 3 843 299 0 3 3 226 0 163 Initial Q (Qb), veh 0 0 0 0 0 0 0 0 0 0 0 0 Lane Width Adj. 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Ped-Bike Adj(A_pbT) 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Parking Bus, Adj 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Work Zone On Approach No No No No Adj Sat Flow, veh/h/ln 1841 1856 1856 1856 1856 1856 1856 1856 1856 1841 1841 1841 Adj Flow Rate, veh/h 400 779 2 3 887 131 0 3 0 238 0 40 Peak Hour Factor 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 Percent Heavy Veh, % 4 3 3 3 3 3 3 3 3 4 4 4 Cap, veh/h 518 1695 756 10 1178 525 14 15 0 430 0 857 Arrive On Green 0.15 0.48 0.48 0.01 0.33 0.33 0.00 0.01 0.00 0.12 0.00 0.12 Sat Flow, veh/h 3401 3526 1572 1767 3526 1572 1767 1856 0 3506 0 3120 Grp Volume(v), veh/h 400 779 2 3 887 131 0 3 0 238 0 40 Grp Sat Flow(s),veh/h/ln 1700 1763 1572 1767 1763 1572 1767 1856 0 1753 0 1560 Q Serve(g_s), s 9.2 12.0 0.1 0.1 18.2 4.9 0.0 0.1 0.0 5.2 0.0 0.8 Cycle Q Clear(g_c), s 9.2 12.0 0.1 0.1 18.2 4.9 0.0 0.1 0.0 5.2 0.0 0.8 Prop In Lane 1.00 1.00 1.00 1.00 1.00 0.00 1.00 1.00 Lane Grp Cap(c), veh/h 518 1695 756 10 1178 525 14 15 0 430 0 857 V/C Ratio(X)0.77 0.46 0.00 0.30 0.75 0.25 0.00 0.20 0.00 0.55 0.00 0.05 Avail Cap(c_a), veh/h 1094 3090 1378 152 2259 1008 586 615 0 1752 0 2034 HCM Platoon Ratio 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Upstream Filter(I) 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00 1.00 0.00 1.00 Uniform Delay (d), s/veh 33.2 14.1 11.0 40.3 24.1 19.7 0.0 40.1 0.0 33.6 0.0 21.7 Incr Delay (d2), s/veh 2.5 0.2 0.0 16.0 1.0 0.2 0.0 6.4 0.0 1.1 0.0 0.0 Initial Q Delay(d3), s/veh 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 %ile BackOfQ(95%),veh/ln 6.7 7.4 0.0 0.2 11.3 3.0 0.0 0.2 0.0 3.9 0.0 0.5 Unsig. Movement Delay, s/veh LnGrp Delay(d), s/veh 35.7 14.3 11.0 56.3 25.1 19.9 0.0 46.6 0.0 34.8 0.0 21.7 LnGrp LOS D B B E C B D C C Approach Vol, veh/h 1181 1021 3 278 Approach Delay, s/veh 21.5 24.6 46.6 32.9 Approach LOS C C D C Timer - Assigned Phs 2 3 4 6 7 8 Phs Duration (G+Y+Rc), s 17.8 20.2 35.0 8.5 8.3 47.0 Change Period (Y+Rc), s 7.8 7.8 7.8 7.8 7.8 7.8 Max Green Setting (Gmax), s 40.7 26.2 52.2 27.0 7.0 71.4 Max Q Clear Time (g_c+I1), s 7.2 11.2 20.2 2.1 2.1 14.0 Green Ext Time (p_c), s 1.0 1.2 7.0 0.0 0.0 5.8 Intersection Summary HCM 7th Control Delay, s/veh 24.1 HCM 7th LOS C Notes User approved pedestrian interval to be less than phase max green. User approved volume balancing among the lanes for turning movement. Page 233 of 456 HCM 7th Signalized Intersection Summary 2031 Post-Dev PM 3: Emerson Ave & Indrio Rd 09/30/2025 Club at Indrio Creek 2031 Post-Dev PM 12:29 pm 09/22/2025 Baseline Synchro 12 Report MEP Page 2 Movement EBL EBT EBR WBL WBT WBR NBL NBT NBR SBL SBT SBR Lane Configurations Traffic Volume (veh/h) 380 740 61 105 843 299 33 19 65 226 25 163 Future Volume (veh/h) 380 740 61 105 843 299 33 19 65 226 25 163 Initial Q (Qb), veh 0 0 0 0 0 0 0 0 0 0 0 0 Lane Width Adj. 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Ped-Bike Adj(A_pbT) 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Parking Bus, Adj 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Work Zone On Approach No No No No Adj Sat Flow, veh/h/ln 1841 1856 1856 1856 1856 1856 1856 1856 1856 1841 1841 1841 Adj Flow Rate, veh/h 400 779 11 111 887 131 35 20 15 257 0 40 Peak Hour Factor 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 Percent Heavy Veh, % 4 3 3 3 3 3 3 3 3 4 4 4 Cap, veh/h 501 1374 613 142 1136 507 158 88 66 375 0 793 Arrive On Green 0.15 0.39 0.39 0.08 0.32 0.32 0.09 0.09 0.09 0.11 0.00 0.11 Sat Flow, veh/h 3401 3526 1572 1767 3526 1572 1767 984 738 3506 0 3120 Grp Volume(v), veh/h 400 779 11 111 887 131 35 0 35 257 0 40 Grp Sat Flow(s),veh/h/ln 1700 1763 1572 1767 1763 1572 1767 0 1723 1753 0 1560 Q Serve(g_s), s 10.6 16.2 0.4 5.8 21.3 5.8 1.7 0.0 1.8 6.6 0.0 0.9 Cycle Q Clear(g_c), s 10.6 16.2 0.4 5.8 21.3 5.8 1.7 0.0 1.8 6.6 0.0 0.9 Prop In Lane 1.00 1.00 1.00 1.00 1.00 0.43 1.00 1.00 Lane Grp Cap(c), veh/h 501 1374 613 142 1136 507 158 0 154 375 0 793 V/C Ratio(X)0.80 0.57 0.02 0.78 0.78 0.26 0.22 0.00 0.23 0.69 0.00 0.05 Avail Cap(c_a), veh/h 953 2225 992 367 1968 878 510 0 498 1526 0 1818 HCM Platoon Ratio 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Upstream Filter(I) 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 1.00 0.00 1.00 Uniform Delay (d), s/veh 38.5 22.4 17.5 42.2 28.7 23.4 39.5 0.0 39.5 40.2 0.0 26.3 Incr Delay (d2), s/veh 3.0 0.4 0.0 9.1 1.2 0.3 0.7 0.0 0.7 2.2 0.0 0.0 Initial Q Delay(d3), s/veh 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 %ile BackOfQ(95%),veh/ln 7.9 10.3 0.2 5.0 13.3 3.7 1.3 0.0 1.3 5.1 0.0 0.6 Unsig. Movement Delay, s/veh LnGrp Delay(d), s/veh 41.5 22.7 17.6 51.3 29.9 23.7 40.2 0.0 40.3 42.5 0.0 26.4 LnGrp LOS D C B D C C D D D C Approach Vol, veh/h 1190 1129 70 297 Approach Delay, s/veh 29.0 31.3 40.3 40.3 Approach LOS C C D D Timer - Assigned Phs 2 3 4 6 7 8 Phs Duration (G+Y+Rc), s 17.8 21.6 37.9 16.2 15.3 44.2 Change Period (Y+Rc), s 7.8 7.8 7.8 7.8 7.8 7.8 Max Green Setting (Gmax), s 40.7 26.2 52.2 27.0 19.4 59.0 Max Q Clear Time (g_c+I1), s 8.6 12.6 23.3 3.8 7.8 18.2 Green Ext Time (p_c), s 1.0 1.2 6.8 0.2 0.2 5.7 Intersection Summary HCM 7th Control Delay, s/veh 31.5 HCM 7th LOS C Notes User approved pedestrian interval to be less than phase max green. User approved volume balancing among the lanes for turning movement. Page 234 of 456 AM PEAK HOUR TURNING MOVEMENTS & Count Taken:2/7/2024 ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr totals7:00 AM 7:15 AM 0 75 52 3 0 3 100 11 0 1 8 4 0 9 7 63 336 7:15 AM 7:30 AM 0 83 100 0 0 1 112 16 0 3 7 2 0 5 8 46 383 7:30 AM 7:45 AM 0 89 101 2 0 10 135 16 0 4 16 6 0 13 11 82 485 7:45 AM 8:00 AM 0 76 93 4 0 1 104 22 0 2 9 7 0 16 6 66 4068:00 AM 8:15 AM 0 65 95 3 0 7 95 10 0 1 14 6 0 20 12 70 398 8:15 AM 8:30 AM 0 56 99 1 0 5 98 6 0 3 18 6 0 13 6 61 372 8:30 AM 8:45 AM 0 70 81 1 0 6 82 8 0 4 10 8 0 10 9 58 347 8:45 AM 9:00 AM 0 58 82 5 0 3 81 15 0 5 13 6 0 13 8 52 3410 572 703 19 0 36 807 104 0 23 95 45 0 99 67 498 3068 7:15 AM 8:15 AM 0 313 389 9 0 19 446 64 0 10 46 21 0 54 37 264 1672 Count Taken:2/8/2024 ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr totals 7:00 AM 7:15 AM 0 47 77 3 0 3 108 7 0 1 14 4 0 10 13 67 354 7:15 AM 7:30 AM 0 70 91 3 0 2 153 16 0 3 13 5 0 11 6 95 4687:30 AM 7:45 AM 0 72 116 3 0 12 152 21 0 4 18 4 0 9 14 81 506 7:45 AM 8:00 AM 0 88 97 4 0 6 103 16 0 5 15 4 0 12 8 101 459 8:00 AM 8:15 AM 0 62 97 1 0 8 80 13 0 5 15 9 0 16 11 65 382 8:15 AM 8:30 AM 0 68 86 2 0 3 89 13 0 2 12 9 0 16 8 63 371 8:30 AM 8:45 AM 0 52 79 1 0 5 85 10 0 4 9 2 0 7 5 53 3128:45 AM 9:00 AM 0 67 105 2 0 5 60 11 0 5 12 10 0 22 9 58 366 0 526 748 19 0 44 830 107 0 29 108 47 0 103 74 583 3218 7:15 AM 8:15 AM 0 292 401 11 0 28 488 66 0 17 61 22 0 48 39 342 1815 7:15 AM 8:15 AM 0 292 401 11 0 28 488 66 0 17 61 22 0 48 39 342 1815 Count Taken:2/8/2024 Buildout year:2031 Growth Rate:3.8%1.0%PSCF:1 PHF 0.90 Adjusted PHF 0.92 ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr 2/8/2024 0 292 401 11 0 28 488 66 0 17 61 22 0 48 39 342 PSCF 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Adjusted Volumes 292 401 11 28 488 66 17 61 22 48 39 342 Growth Rate 3.8% 3.8% 3.8%3.8% 3.8% 3.8%3.8% 3.8% 3.8%3.8% 3.8% 3.8% 2031 Growth 102 139 4 10 170 23 6 21 8 17 14 119Growth 3.8%394 540 15 38 658 89 23 82 30 65 53 461 Growth Rate 1.0% 1.0% 1.0%1.0% 1.0% 1.0%1.0% 1.0% 1.0%1.0% 1.0% 1.0% 2031 Growth 24 33 1 2 40 5 1 5 2 4 3 28 Growth 1%316 434 12 30 528 71 18 66 24 52 42 370 Committed ProjectsPublix at Indrio AM IN 65 OUT 53 In/Out In Out Out In %0% 0% 8% 0% 0% 0% 8% 2% 0% 0% 0% 0% 0% 2% 0% 0% Volumes 0 0 5 0 0 0 4 1 0 0 0 0 0 1 0 0Indrio Woods AM IN 26 OUT 89 In/Out %0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Sabal Palm Grove AM IN 11 OUT 34In/Out %0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Cabo Rio RV Resort AM IN 15 OUT 27In/Out %0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Indrio & I-95 Development (25%)AM IN 270 OUT 267In/Out Out Out In In Out Out In In %0% 5% 10% 0% 0% 16% 10% 0% 0% 0% 13% 16% 0% 0% 13% 5% Volumes 0 13 27 0 0 43 27 0 0 0 35 43 0 0 35 14 Indrio Groves (25%)AM IN 95 OUT 275In/Out Out Out Out In In In %0% 6% 28% 4% 0% 0% 28% 0% 0% 4% 0% 0% 0% 0% 0% 6% Volumes 0 17 77 11 0 0 26 0 0 4 0 0 0 0 0 6 Bedner Farms (25%)AM IN 83 OUT 130In/Out Out Out In In %0% 10% 51% 0% 0% 0% 51% 0% 0% 0% 0% 0% 0% 0% 0% 10% Volumes 0 13 66 0 0 0 42 0 0 0 0 0 0 0 0 8 Eagle Bend (25%)AM In 52 Out 158In/Out % Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Buc-ee's AM IN 610 OUT 570 In/Out Out Out Out In In In%5% 7% 3%7%3%5% Volumes 0 26 37 14 0 0 40 0 0 15 0 0 0 0 0 27 2098 Johnston Rd (25%)AM IN 4 OUT 12 In/Out IN IN OUT OUT OUT IN%27%5%27% 2% 5%2% Volumes 0 0 0 1 0 0 0 0 0 3 0 1 0 0 0 0 Total Committed 0 68 212 26 0 43 140 1 0 22 35 43 0 1 35 55 Committed + 1%0 384 646 38 0 73 668 72 0 40 101 67 0 53 77 425 Weighted T-Factor 5.7% 5.0% 2.8%3.4% 5.7% 5.6%3.7% 4.9% 3.1%5.5% 4.2% 5.7% Growth 3.8% or Committed + 1%394 646 38 73 668 89 40 101 67 65 77 461 2031 Pre-Development 394 646 38 73 668 89 40 101 67 65 77 461 Project Volumes 0 9 0 14 26 12 0 0 5 4 0 0 Post-Development 394 655 38 87 694 101 40 101 72 69 77 461 % Trucks In Out Out Out In In 0% 0% 15% 0% 0% 8% 15% 7% 0% 0% 0% 8% 0% 7% 0% 0% ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr Existing 0 292 401 11 0 28 488 66 0 17 61 22 0 48 39 342Pre-Development 0 394 646 38 0 73 668 89 0 40 101 67 0 65 77 461 Post-Development 0 394 655 38 0 87 694 101 0 40 101 72 0 69 77 461 Club at Indrio Creek Johnston Rd Indrio RdEXHIBIT 1G Assignment Peak Hour Traffic Volume Peak Hour Traffic Volume Maximum Peak Hour Traffic Volume 6.4%7.7%7.0%5.1% Page 235 of 456 HCM 7th Signalized Intersection Summary 2025 Existing AM 4: Johnston Rd & Indrio Rd 09/30/2025 Club at Indrio Creek 2025 Existing AM 12:29 pm 09/22/2025 Baseline Synchro 12 Report MEP Page 3 Movement EBL EBT EBR WBL WBT WBR NBL NBT NBR SBL SBT SBR Lane Configurations Traffic Volume (veh/h) 292 401 11 28 488 66 17 61 22 48 39 342 Future Volume (veh/h) 292 401 11 28 488 66 17 61 22 48 39 342 Initial Q (Qb), veh 0 0 0 0 0 0 0 0 0 0 0 0 Lane Width Adj. 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Ped-Bike Adj(A_pbT) 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Parking Bus, Adj 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Work Zone On Approach No No No No Adj Sat Flow, veh/h/ln 1811 1826 1856 1841 1811 1811 1841 1826 1841 1811 1841 1811 Adj Flow Rate, veh/h 317 436 7 30 530 18 18 66 8 47 49 100 Peak Hour Factor 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 Percent Heavy Veh, % 6 5 3 4 6 6 4 5 4 6 4 6 Cap, veh/h 432 1039 471 74 733 327 285 297 639 317 338 961 Arrive On Green 0.13 0.30 0.30 0.04 0.21 0.21 0.16 0.16 0.16 0.18 0.18 0.18 Sat Flow, veh/h 3346 3469 1572 1753 3441 1535 1753 1826 3120 1725 1841 3070 Grp Volume(v), veh/h 317 436 7 30 530 18 18 66 8 47 49 100 Grp Sat Flow(s),veh/h/ln 1673 1735 1572 1753 1721 1535 1753 1826 1560 1725 1841 1535 Q Serve(g_s), s 7.3 8.1 0.3 1.3 11.5 0.8 0.7 2.5 0.2 1.8 1.8 1.9 Cycle Q Clear(g_c), s 7.3 8.1 0.3 1.3 11.5 0.8 0.7 2.5 0.2 1.8 1.8 1.9 Prop In Lane 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Lane Grp Cap(c), veh/h 432 1039 471 74 733 327 285 297 639 317 338 961 V/C Ratio(X)0.73 0.42 0.01 0.40 0.72 0.06 0.06 0.22 0.01 0.15 0.14 0.10 Avail Cap(c_a), veh/h 1495 3510 1591 261 2503 1117 940 979 1806 1021 1090 2214 HCM Platoon Ratio 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Upstream Filter(I) 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Uniform Delay (d), s/veh 33.8 22.6 19.8 37.6 29.5 25.2 28.5 29.3 25.5 27.6 27.6 19.7 Incr Delay (d2), s/veh 2.4 0.3 0.0 3.5 1.4 0.1 0.1 0.4 0.0 0.2 0.2 0.0 Initial Q Delay(d3), s/veh 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 %ile BackOfQ(95%),veh/ln 5.3 5.5 0.2 1.1 8.0 0.5 0.5 1.9 0.1 1.3 1.4 1.1 Unsig. Movement Delay, s/veh LnGrp Delay(d), s/veh 36.2 22.9 19.9 41.0 30.9 25.3 28.6 29.7 25.5 27.8 27.8 19.7 LnGrp LOS D C B D C C C C C C C B Approach Vol, veh/h 760 578 92 196 Approach Delay, s/veh 28.4 31.2 29.1 23.7 Approach LOS C C C C Timer - Assigned Phs 2 3 4 6 7 8 Phs Duration (G+Y+Rc), s 21.6 14.4 24.7 19.9 7.4 31.6 Change Period (Y+Rc), s 6.8 4.0 * 7.5 6.8 4.0 7.5 Max Green Setting (Gmax), s 47.7 36.0 * 59 43.2 12.0 81.5 Max Q Clear Time (g_c+I1), s 3.9 9.3 13.5 4.5 3.3 10.1 Green Ext Time (p_c), s 0.8 1.1 3.6 0.4 0.0 2.9 Intersection Summary HCM 7th Control Delay, s/veh 28.9 HCM 7th LOS C Notes User approved volume balancing among the lanes for turning movement. * HCM 7th computational engine requires equal clearance times for the phases crossing the barrier. Page 236 of 456 HCM 7th Signalized Intersection Summary 2031 Pre-Dev AM 4: Johnston Rd & Indrio Rd 09/30/2025 Club at Indrio Creek 2031 Pre-Dev AM 12:29 pm 09/22/2025 Baseline Synchro 12 Report MEP Page 3 Movement EBL EBT EBR WBL WBT WBR NBL NBT NBR SBL SBT SBR Lane Configurations Traffic Volume (veh/h) 394 646 38 73 668 89 40 101 67 65 77 461 Future Volume (veh/h) 394 646 38 73 668 89 40 101 67 65 77 461 Initial Q (Qb), veh 0 0 0 0 0 0 0 0 0 0 0 0 Lane Width Adj. 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Ped-Bike Adj(A_pbT) 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Parking Bus, Adj 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Work Zone On Approach No No No No Adj Sat Flow, veh/h/ln 1811 1826 1856 1841 1811 1811 1841 1826 1841 1811 1841 1811 Adj Flow Rate, veh/h 428 702 8 79 726 10 43 110 8 71 84 66 Peak Hour Factor 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 Percent Heavy Veh, % 6 5 3 4 6 6 4 5 4 6 4 6 Cap, veh/h 533 1268 575 112 929 414 270 281 680 268 286 967 Arrive On Green 0.16 0.37 0.37 0.06 0.27 0.27 0.15 0.15 0.15 0.16 0.16 0.16 Sat Flow, veh/h 3346 3469 1572 1753 3441 1535 1753 1826 3120 1725 1841 3070 Grp Volume(v), veh/h 428 702 8 79 726 10 43 110 8 71 84 66 Grp Sat Flow(s),veh/h/ln 1673 1735 1572 1753 1721 1535 1753 1826 1560 1725 1841 1535 Q Serve(g_s), s 11.9 15.5 0.3 4.2 18.8 0.5 2.0 5.2 0.2 3.5 3.9 1.4 Cycle Q Clear(g_c), s 11.9 15.5 0.3 4.2 18.8 0.5 2.0 5.2 0.2 3.5 3.9 1.4 Prop In Lane 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Lane Grp Cap(c), veh/h 533 1268 575 112 929 414 270 281 680 268 286 967 V/C Ratio(X)0.80 0.55 0.01 0.70 0.78 0.02 0.16 0.39 0.01 0.26 0.29 0.07 Avail Cap(c_a), veh/h 1358 2833 1284 346 2133 952 751 783 1537 820 875 1949 HCM Platoon Ratio 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Upstream Filter(I) 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Uniform Delay (d), s/veh 38.9 24.3 19.5 44.1 32.5 25.8 35.3 36.6 29.5 35.7 35.9 23.0 Incr Delay (d2), s/veh 2.9 0.4 0.0 7.8 1.5 0.0 0.3 0.9 0.0 0.5 0.6 0.0 Initial Q Delay(d3), s/veh 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 %ile BackOfQ(95%),veh/ln 8.5 10.0 0.2 3.6 12.0 0.3 1.5 4.1 0.1 2.6 3.1 0.9 Unsig. Movement Delay, s/veh LnGrp Delay(d), s/veh 41.8 24.6 19.5 51.9 33.9 25.8 35.5 37.5 29.5 36.3 36.5 23.1 LnGrp LOS D C B D C C D D C D D C Approach Vol, veh/h 1138 815 161 221 Approach Delay, s/veh 31.1 35.6 36.6 32.4 Approach LOS C D D C Timer - Assigned Phs 2 3 4 6 7 8 Phs Duration (G+Y+Rc), s 21.8 19.3 33.5 21.6 10.2 42.6 Change Period (Y+Rc), s 6.8 4.0 * 7.5 6.8 4.0 7.5 Max Green Setting (Gmax), s 45.7 39.0 * 60 41.2 19.0 78.5 Max Q Clear Time (g_c+I1), s 5.9 13.9 20.8 7.2 6.2 17.5 Green Ext Time (p_c), s 0.9 1.5 5.2 0.7 0.1 5.1 Intersection Summary HCM 7th Control Delay, s/veh 33.2 HCM 7th LOS C Notes User approved volume balancing among the lanes for turning movement. * HCM 7th computational engine requires equal clearance times for the phases crossing the barrier. Page 237 of 456 HCM 7th Signalized Intersection Summary 2031 Post-Dev AM 4: Johnston Rd & Indrio Rd 09/30/2025 Club at Indrio Creek 2031 Post-Dev AM 12:29 pm 09/22/2025 Baseline Synchro 12 Report MEP Page 3 Movement EBL EBT EBR WBL WBT WBR NBL NBT NBR SBL SBT SBR Lane Configurations Traffic Volume (veh/h) 394 655 38 87 694 101 40 101 72 69 77 461 Future Volume (veh/h) 394 655 38 87 694 101 40 101 72 69 77 461 Initial Q (Qb), veh 0 0 0 0 0 0 0 0 0 0 0 0 Lane Width Adj. 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Ped-Bike Adj(A_pbT) 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Parking Bus, Adj 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Work Zone On Approach No No No No Adj Sat Flow, veh/h/ln 1811 1826 1856 1841 1811 1811 1841 1826 1841 1811 1841 1811 Adj Flow Rate, veh/h 428 712 8 95 754 23 43 110 13 75 84 66 Peak Hour Factor 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 Percent Heavy Veh, % 6 5 3 4 6 6 4 5 4 6 4 6 Cap, veh/h 531 1277 579 122 960 428 266 277 691 264 282 958 Arrive On Green 0.16 0.37 0.37 0.07 0.28 0.28 0.15 0.15 0.15 0.15 0.15 0.15 Sat Flow, veh/h 3346 3469 1572 1753 3441 1535 1753 1826 3120 1725 1841 3070 Grp Volume(v), veh/h 428 712 8 95 754 23 43 110 13 75 84 66 Grp Sat Flow(s),veh/h/ln 1673 1735 1572 1753 1721 1535 1753 1826 1560 1725 1841 1535 Q Serve(g_s), s 12.1 15.9 0.3 5.2 19.8 1.1 2.1 5.3 0.3 3.8 4.0 1.5 Cycle Q Clear(g_c), s 12.1 15.9 0.3 5.2 19.8 1.1 2.1 5.3 0.3 3.8 4.0 1.5 Prop In Lane 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Lane Grp Cap(c), veh/h 531 1277 579 122 960 428 266 277 691 264 282 958 V/C Ratio(X)0.81 0.56 0.01 0.78 0.79 0.05 0.16 0.40 0.02 0.28 0.30 0.07 Avail Cap(c_a), veh/h 1302 2753 1248 377 2170 968 739 770 1533 789 842 1892 HCM Platoon Ratio 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Upstream Filter(I) 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Uniform Delay (d), s/veh 39.6 24.5 19.6 44.7 32.5 25.8 36.0 37.4 29.7 36.6 36.7 23.6 Incr Delay (d2), s/veh 2.9 0.4 0.0 10.1 1.5 0.1 0.3 0.9 0.0 0.6 0.6 0.0 Initial Q Delay(d3), s/veh 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 %ile BackOfQ(95%),veh/ln 8.6 10.2 0.2 4.5 12.5 0.7 1.6 4.2 0.2 2.8 3.2 0.9 Unsig. Movement Delay, s/veh LnGrp Delay(d), s/veh 42.6 24.9 19.6 54.8 34.0 25.8 36.3 38.3 29.7 37.2 37.3 23.7 LnGrp LOS D C B D C C D D C D D C Approach Vol, veh/h 1148 872 166 225 Approach Delay, s/veh 31.4 36.0 37.1 33.2 Approach LOS C D D C Timer - Assigned Phs 2 3 4 6 7 8 Phs Duration (G+Y+Rc), s 21.8 19.5 34.8 21.6 10.8 43.5 Change Period (Y+Rc), s 6.8 4.0 * 7.5 6.8 4.0 7.5 Max Green Setting (Gmax), s 44.7 38.0 * 62 41.2 21.0 77.5 Max Q Clear Time (g_c+I1), s 6.0 14.1 21.8 7.3 7.2 17.9 Green Ext Time (p_c), s 0.9 1.5 5.5 0.7 0.2 5.2 Intersection Summary HCM 7th Control Delay, s/veh 33.7 HCM 7th LOS C Notes User approved volume balancing among the lanes for turning movement. * HCM 7th computational engine requires equal clearance times for the phases crossing the barrier. Page 238 of 456 PM PEAK HOUR TURNING MOVEMENTS & Count Taken:2/7/2024 ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr totals4:00 PM 4:15 PM 1 56 123 3 0 3 75 14 0 4 8 3 0 21 18 83 412 4:15 PM 4:30 PM 0 74 105 5 0 8 99 21 0 7 17 9 0 10 18 77 450 4:30 PM 4:45 PM 0 83 150 1 0 9 107 16 0 6 13 9 0 12 20 108 534 4:45 PM 5:00 PM 0 76 139 11 0 10 105 19 0 2 11 13 0 25 13 71 4955:00 PM 5:15 PM 0 94 137 3 0 8 104 21 0 3 15 13 0 18 22 76 514 5:15 PM 5:30 PM 0 69 141 5 0 4 91 22 0 3 21 11 0 19 19 100 505 5:30 PM 5:45 PM 0 78 137 6 0 13 101 18 0 2 17 12 0 17 20 87 508 5:45 PM 6:00 PM 0 59 114 2 0 5 82 17 0 2 10 8 0 16 14 58 3871 589 1046 36 0 60 764 148 0 29 112 78 0 138 144 660 3805 4:30 PM 5:30 PM 0 322 567 20 0 31 407 78 0 14 60 46 0 74 74 355 2048 Count Taken:2/8/2024 ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr totals 4:00 PM 4:15 PM 0 59 115 3 0 4 91 15 0 5 14 20 1 14 22 99 462 4:15 PM 4:30 PM 0 71 129 7 0 11 99 16 0 2 25 13 1 19 33 90 5164:30 PM 4:45 PM 0 75 132 7 0 6 126 10 0 2 11 11 1 22 20 79 502 4:45 PM 5:00 PM 0 86 127 7 0 4 131 21 0 5 11 18 1 17 12 58 498 5:00 PM 5:15 PM 0 85 148 7 0 7 95 17 0 2 17 6 0 10 16 89 499 5:15 PM 5:30 PM 0 83 141 1 0 8 116 23 0 2 10 7 0 16 16 93 516 5:30 PM 5:45 PM 0 77 110 1 0 5 99 14 0 2 12 11 0 18 21 80 4505:45 PM 6:00 PM 0 62 105 3 1 6 77 13 0 2 8 8 0 12 15 77 389 0 598 1007 36 1 51 834 129 0 22 108 94 4 128 155 665 3832 4:15 PM 5:15 PM 0 317 536 28 0 28 451 64 0 11 64 48 3 68 81 316 2015 4:30 PM 5:30 PM 0 322 567 20 0 31 407 78 0 14 60 46 0 74 74 355 2048 Count Taken:2/7/2024 Buildout year:2031 Growth Rate:3.8%1.0%PSCF:1 PHF 0.96 Adjusted PHF 0.95 ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr 2/7/2024 0 322 567 20 0 31 407 78 0 14 60 46 0 74 74 355 PSCF 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Adjusted Volumes 322 567 20 31 407 78 14 60 46 74 74 355 Growth Rate 3.8% 3.8% 3.8%3.8% 3.8% 3.8%3.8% 3.8% 3.8%3.8% 3.8% 3.8% 2031 Growth 112 197 7 11 141 27 5 21 16 26 26 123Growth 3.8%434 764 27 42 548 105 19 81 62 100 100 478 Growth Rate 1.0% 1.0% 1.0%1.0% 1.0% 1.0%1.0% 1.0% 1.0%1.0% 1.0% 1.0% 2031 Growth 27 47 2 3 34 6 1 5 4 6 6 29 Growth 1%349 614 22 34 441 84 15 65 50 80 80 384 Committed ProjectsPublix at Indrio PM IN 136 OUT 142 In/Out In Out Out In %0% 0% 8% 0% 0% 0% 8% 2% 0% 0% 0% 0% 0% 2% 0% 0% Volumes 0 0 11 0 0 0 11 3 0 0 0 0 0 3 0 0Indrio Woods PM IN 69 OUT 44 In/Out %0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Sabal Palm Grove PM IN 32 OUT 22In/Out %0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Cabo Rio RV Resort PM IN 36 OUT 19In/Out %0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Indrio & I-95 Development (25%)PM IN 373 OUT 386In/Out Out Out In In Out Out In In %0% 5% 10% 0% 0% 16% 10% 0% 0% 0% 13% 16% 0% 0% 13% 5% Volumes 0 19 39 0 0 60 37 0 0 0 50 62 0 0 48 19 Indrio Groves (25%)PM IN 335 OUT 197In/Out Out Out Out In In In %0% 6% 28% 4% 0% 0% 28% 0% 0% 4% 0% 0% 0% 0% 0% 6% Volumes 0 12 55 8 0 0 94 0 0 13 0 0 0 0 0 20 Bedner Farms (25%)PM IN 204 OUT 173In/Out Out Out In In %0% 10% 51% 0% 0% 0% 51% 0% 0% 0% 0% 0% 0% 0% 0% 10% Volumes 0 17 88 0 0 0 104 0 0 0 0 0 0 0 0 20 Eagle Bend (25%)PM In 185 Out 109In/Out % Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Buc-ee's PM IN 772 OUT 786 In/Out Out Out Out In In In%5% 7% 3%7%3%5% Volumes 0 35 51 20 0 0 50 0 0 19 0 0 0 0 0 35 2098 Johnston Rd (25%)PM IN 13 OUT 8 In/Out IN IN OUT OUT OUT IN%27%5%27% 2% 5%2% Volumes 0 0 0 4 0 1 0 0 0 2 0 0 0 0 0 0 Total Committed 0 84 244 31 0 60 296 3 0 35 50 62 0 3 49 94 Committed + 1%0 433 858 53 0 94 737 87 0 50 115 112 0 83 129 478 Weighted T-Factor 4.3% 3.9% 2.7%2.4% 3.4% 4.1%2.2% 3.3% 2.8%4.1% 3.5% 4.3% Growth 3.8% or Committed + 1%434 858 53 94 737 105 50 115 112 100 129 478 2031 Pre-Development 434 858 53 94 737 105 50 115 112 100 129 478 Project Volumes 0 27 0 9 17 8 0 0 15 13 0 0 Post-Development 434 885 53 103 754 113 50 115 127 113 129 478 % Trucks In Out Out Out In In 0% 0% 15% 0% 0% 8% 15% 7% 0% 0% 0% 8% 0% 7% 0% 0% ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr Existing 0 322 567 20 0 31 407 78 0 14 60 46 0 74 74 355Pre-Development 0 434 858 53 0 94 737 105 0 50 115 112 0 100 129 478 Post-Development 0 434 885 53 0 103 754 113 0 50 115 127 0 113 129 478 2.3%0.0%2.8% EXHIBIT 1H Johnston Rd Indrio Rd Peak Hour Traffic Volume Club at Indrio Creek Peak Hour Traffic Volume Assignment Maximum Peak Hour Traffic Volume 4.4% Page 239 of 456 HCM 7th Signalized Intersection Summary 2025 Existing PM 4: Johnston Rd & Indrio Rd 09/30/2025 Club at Indrio Creek 2025 Existing PM 12:29 pm 09/22/2025 Baseline Synchro 12 Report MEP Page 3 Movement EBL EBT EBR WBL WBT WBR NBL NBT NBR SBL SBT SBR Lane Configurations Traffic Volume (veh/h) 322 567 20 31 407 78 14 60 46 74 74 355 Future Volume (veh/h) 322 567 20 31 407 78 14 60 46 74 74 355 Initial Q (Qb), veh 0 0 0 0 0 0 0 0 0 0 0 0 Lane Width Adj. 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Ped-Bike Adj(A_pbT) 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Parking Bus, Adj 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Work Zone On Approach No No No No Adj Sat Flow, veh/h/ln 1826 1841 1856 1856 1856 1826 1856 1841 1856 1826 1841 1826 Adj Flow Rate, veh/h 339 597 5 33 428 29 15 63 6 78 78 58 Peak Hour Factor 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 Percent Heavy Veh, % 5 4 3 3 3 5 3 4 3 5 4 5 Cap, veh/h 464 939 422 82 625 274 288 300 658 337 357 1026 Arrive On Green 0.14 0.27 0.27 0.05 0.18 0.18 0.16 0.16 0.16 0.19 0.19 0.19 Sat Flow, veh/h 3374 3497 1572 1767 3526 1547 1767 1841 3145 1739 1841 3095 Grp Volume(v), veh/h 339 597 5 33 428 29 15 63 6 78 78 58 Grp Sat Flow(s),veh/h/ln 1687 1749 1572 1767 1763 1547 1767 1841 1572 1739 1841 1547 Q Serve(g_s), s 7.4 11.5 0.2 1.4 8.7 1.2 0.5 2.3 0.1 2.9 2.7 1.0 Cycle Q Clear(g_c), s 7.4 11.5 0.2 1.4 8.7 1.2 0.5 2.3 0.1 2.9 2.7 1.0 Prop In Lane 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Lane Grp Cap(c), veh/h 464 939 422 82 625 274 288 300 658 337 357 1026 V/C Ratio(X)0.73 0.64 0.01 0.40 0.68 0.11 0.05 0.21 0.01 0.23 0.22 0.06 Avail Cap(c_a), veh/h 1676 3680 1655 277 2562 1125 998 1039 1921 1107 1172 2395 HCM Platoon Ratio 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Upstream Filter(I) 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Uniform Delay (d), s/veh 31.6 24.7 20.5 35.5 29.5 26.4 27.0 27.7 24.0 26.0 25.9 17.4 Incr Delay (d2), s/veh 2.2 0.7 0.0 3.2 1.3 0.2 0.1 0.3 0.0 0.3 0.3 0.0 Initial Q Delay(d3), s/veh 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 %ile BackOfQ(95%),veh/ln 5.3 7.8 0.1 1.1 6.3 0.8 0.4 1.7 0.1 2.0 2.0 0.6 Unsig. Movement Delay, s/veh LnGrp Delay(d), s/veh 33.9 25.4 20.5 38.7 30.8 26.6 27.1 28.1 24.0 26.4 26.3 17.4 LnGrp LOS C C C D C C C C C C C B Approach Vol, veh/h 941 490 84 214 Approach Delay, s/veh 28.4 31.1 27.6 23.9 Approach LOS C C C C Timer - Assigned Phs 2 3 4 6 7 8 Phs Duration (G+Y+Rc), s 21.6 14.5 21.1 19.3 7.5 28.0 Change Period (Y+Rc), s 6.8 4.0 * 7.5 6.8 4.0 7.5 Max Green Setting (Gmax), s 48.7 38.0 * 56 43.2 12.0 80.5 Max Q Clear Time (g_c+I1), s 4.9 9.4 10.7 4.3 3.4 13.5 Green Ext Time (p_c), s 0.8 1.2 2.9 0.3 0.0 4.1 Intersection Summary HCM 7th Control Delay, s/veh 28.6 HCM 7th LOS C Notes User approved volume balancing among the lanes for turning movement. * HCM 7th computational engine requires equal clearance times for the phases crossing the barrier. Page 240 of 456 HCM 7th Signalized Intersection Summary 2031 Pre-Dev PM 4: Johnston Rd & Indrio Rd 09/30/2025 Club at Indrio Creek 2031 Pre-Dev PM 12:29 pm 09/22/2025 Baseline Synchro 12 Report MEP Page 3 Movement EBL EBT EBR WBL WBT WBR NBL NBT NBR SBL SBT SBR Lane Configurations Traffic Volume (veh/h) 434 858 53 94 737 105 50 115 112 100 129 478 Future Volume (veh/h) 434 858 53 94 737 105 50 115 112 100 129 478 Initial Q (Qb), veh 0 0 0 0 0 0 0 0 0 0 0 0 Lane Width Adj. 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Ped-Bike Adj(A_pbT) 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Parking Bus, Adj 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Work Zone On Approach No No No No Adj Sat Flow, veh/h/ln 1826 1841 1856 1856 1856 1826 1856 1841 1856 1826 1841 1826 Adj Flow Rate, veh/h 457 903 9 99 776 11 53 121 18 105 136 61 Peak Hour Factor 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 Percent Heavy Veh, % 5 4 3 3 3 5 3 4 3 5 4 5 Cap, veh/h 562 1310 589 127 986 433 265 276 698 262 278 983 Arrive On Green 0.17 0.37 0.37 0.07 0.28 0.28 0.15 0.15 0.15 0.15 0.15 0.15 Sat Flow, veh/h 3374 3497 1572 1767 3526 1547 1767 1841 3145 1739 1841 3095 Grp Volume(v), veh/h 457 903 9 99 776 11 53 121 18 105 136 61 Grp Sat Flow(s),veh/h/ln 1687 1749 1572 1767 1763 1547 1767 1841 1572 1739 1841 1547 Q Serve(g_s), s 13.0 21.6 0.4 5.5 20.2 0.5 2.6 5.9 0.4 5.4 6.7 1.4 Cycle Q Clear(g_c), s 13.0 21.6 0.4 5.5 20.2 0.5 2.6 5.9 0.4 5.4 6.7 1.4 Prop In Lane 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Lane Grp Cap(c), veh/h 562 1310 589 127 986 433 265 276 698 262 278 983 V/C Ratio(X)0.81 0.69 0.02 0.78 0.79 0.03 0.20 0.44 0.03 0.40 0.49 0.06 Avail Cap(c_a), veh/h 1358 2727 1226 373 2114 928 715 745 1498 800 846 1939 HCM Platoon Ratio 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Upstream Filter(I) 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Uniform Delay (d), s/veh 39.9 26.2 19.6 45.3 33.1 26.0 37.0 38.4 30.2 38.1 38.7 23.6 Incr Delay (d2), s/veh 2.9 0.7 0.0 9.9 1.4 0.0 0.4 1.1 0.0 1.0 1.3 0.0 Initial Q Delay(d3), s/veh 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 %ile BackOfQ(95%),veh/ln 9.2 13.2 0.2 4.8 13.0 0.3 2.0 4.8 0.3 4.1 5.4 0.9 Unsig. Movement Delay, s/veh LnGrp Delay(d), s/veh 42.8 26.9 19.6 55.2 34.5 26.0 37.4 39.5 30.3 39.1 40.0 23.6 LnGrp LOS D C B E C C D D C D D C Approach Vol, veh/h 1369 886 192 302 Approach Delay, s/veh 32.1 36.7 38.0 36.4 Approach LOS C D D D Timer - Assigned Phs 2 3 4 6 7 8 Phs Duration (G+Y+Rc), s 21.8 20.6 35.3 21.7 11.1 44.7 Change Period (Y+Rc), s 6.8 4.0 * 7.5 6.8 4.0 7.5 Max Green Setting (Gmax), s 45.7 40.0 * 60 40.2 21.0 77.5 Max Q Clear Time (g_c+I1), s 8.7 15.0 22.2 7.9 7.5 23.6 Green Ext Time (p_c), s 1.2 1.6 5.6 0.8 0.2 7.1 Intersection Summary HCM 7th Control Delay, s/veh 34.5 HCM 7th LOS C Notes User approved volume balancing among the lanes for turning movement. * HCM 7th computational engine requires equal clearance times for the phases crossing the barrier. Page 241 of 456 HCM 7th Signalized Intersection Summary 2031 Post-Dev PM 4: Johnston Rd & Indrio Rd 09/30/2025 Club at Indrio Creek 2031 Post-Dev PM 12:29 pm 09/22/2025 Baseline Synchro 12 Report MEP Page 3 Movement EBL EBT EBR WBL WBT WBR NBL NBT NBR SBL SBT SBR Lane Configurations Traffic Volume (veh/h) 434 885 53 103 754 113 50 115 127 113 129 478 Future Volume (veh/h) 434 885 53 103 754 113 50 115 127 113 129 478 Initial Q (Qb), veh 0 0 0 0 0 0 0 0 0 0 0 0 Lane Width Adj. 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Ped-Bike Adj(A_pbT) 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Parking Bus, Adj 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Work Zone On Approach No No No No Adj Sat Flow, veh/h/ln 1826 1841 1856 1856 1856 1826 1856 1841 1856 1826 1841 1826 Adj Flow Rate, veh/h 457 932 9 108 794 19 53 121 34 119 136 61 Peak Hour Factor 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 Percent Heavy Veh, % 5 4 3 3 3 5 3 4 3 5 4 5 Cap, veh/h 561 1307 588 137 1006 442 263 274 713 260 275 977 Arrive On Green 0.17 0.37 0.37 0.08 0.29 0.29 0.15 0.15 0.15 0.15 0.15 0.15 Sat Flow, veh/h 3374 3497 1572 1767 3526 1547 1767 1841 3145 1739 1841 3095 Grp Volume(v), veh/h 457 932 9 108 794 19 53 121 34 119 136 61 Grp Sat Flow(s),veh/h/ln 1687 1749 1572 1767 1763 1547 1767 1841 1572 1739 1841 1547 Q Serve(g_s), s 13.1 22.8 0.4 6.0 20.9 0.9 2.6 6.0 0.8 6.3 6.8 1.4 Cycle Q Clear(g_c), s 13.1 22.8 0.4 6.0 20.9 0.9 2.6 6.0 0.8 6.3 6.8 1.4 Prop In Lane 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Lane Grp Cap(c), veh/h 561 1307 588 137 1006 442 263 274 713 260 275 977 V/C Ratio(X)0.82 0.71 0.02 0.79 0.79 0.04 0.20 0.44 0.05 0.46 0.49 0.06 Avail Cap(c_a), veh/h 1311 2665 1198 387 2128 934 708 737 1504 792 838 1923 HCM Platoon Ratio 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Upstream Filter(I) 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Uniform Delay (d), s/veh 40.4 26.8 19.8 45.5 33.1 25.9 37.5 38.9 30.3 39.0 39.2 24.0 Incr Delay (d2), s/veh 3.0 0.7 0.0 9.4 1.4 0.0 0.4 1.1 0.0 1.3 1.4 0.0 Initial Q Delay(d3), s/veh 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 %ile BackOfQ(95%),veh/ln 9.3 13.9 0.2 5.2 13.4 0.6 2.0 4.9 0.6 4.8 5.5 0.9 Unsig. Movement Delay, s/veh LnGrp Delay(d), s/veh 43.3 27.6 19.8 54.9 34.5 26.0 37.9 40.0 30.4 40.2 40.6 24.0 LnGrp LOS D C B D C C D D C D D C Approach Vol, veh/h 1398 921 208 316 Approach Delay, s/veh 32.7 36.7 37.9 37.3 Approach LOS C D D D Timer - Assigned Phs 2 3 4 6 7 8 Phs Duration (G+Y+Rc), s 21.8 20.7 36.2 21.8 11.8 45.0 Change Period (Y+Rc), s 6.8 4.0 * 7.5 6.8 4.0 7.5 Max Green Setting (Gmax), s 45.7 39.0 * 61 40.2 22.0 76.5 Max Q Clear Time (g_c+I1), s 8.8 15.1 22.9 8.0 8.0 24.8 Green Ext Time (p_c), s 1.3 1.6 5.8 0.9 0.2 7.4 Intersection Summary HCM 7th Control Delay, s/veh 34.9 HCM 7th LOS C Notes User approved volume balancing among the lanes for turning movement. * HCM 7th computational engine requires equal clearance times for the phases crossing the barrier. Page 242 of 456 AM PEAK HOUR TURNING MOVEMENTS & Count Taken:2/7/2024 ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr totals 7:00 AM 7:15 AM 0 2 120 0 0 0 159 0 0 0 0 0 0 11 0 10 302 7:15 AM 7:30 AM 0 1 184 0 0 0 157 0 0 0 0 0 0 11 0 9 362 7:30 AM 7:45 AM 0 1 167 0 0 0 229 0 0 0 0 0 0 14 0 14 425 7:45 AM 8:00 AM 0 8 169 0 0 0 170 0 0 0 0 0 0 20 0 9 376 8:00 AM 8:15 AM 0 2 133 0 0 0 159 0 0 0 0 0 0 24 0 12 330 8:15 AM 8:30 AM 0 4 130 0 0 0 157 0 0 0 0 0 0 18 0 10 319 8:30 AM 8:45 AM 0 8 120 0 0 0 160 0 0 0 0 0 0 35 0 9 332 8:45 AM 9:00 AM 0 6 111 0 0 0 135 0 0 0 0 0 0 37 0 17 306 0 32 1134 0 0 0 1326 0 0 0 0 0 0 170 0 90 2752 7:15 AM 8:15 AM 0 12 653 0 0 0 715 0 0 0 0 0 0 69 0 44 1493 Count Taken:2/8/2024 ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr totals 7:00 AM 7:15 AM 0 3 127 0 0 0 167 0 0 0 0 0 0 16 0 13 326 7:15 AM 7:30 AM 0 2 139 0 0 0 232 0 0 0 0 0 0 9 0 9 391 7:30 AM 7:45 AM 0 4 185 0 0 0 245 0 0 0 0 0 0 18 0 15 467 7:45 AM 8:00 AM 0 5 169 0 0 0 216 0 0 0 0 0 0 12 0 10 412 8:00 AM 8:15 AM 1 9 141 0 0 0 155 0 0 0 0 0 0 16 0 17 339 8:15 AM 8:30 AM 1 9 138 0 0 0 161 0 0 0 0 0 0 19 0 8 336 8:30 AM 8:45 AM 0 2 112 0 0 0 141 0 0 0 0 0 0 23 0 6 284 8:45 AM 9:00 AM 2 4 137 0 1 0 121 0 0 0 0 0 0 33 0 11 309 4 38 1148 0 1 0 1438 0 0 0 0 0 0 146 0 89 2864 7:15 AM 8:15 AM 1 20 634 0 0 0 848 0 0 0 0 0 0 55 0 51 1609 7:15 AM 8:15 AM 1 20 634 0 0 0 848 0 0 0 0 0 0 55 0 51 1609 Count Taken:2/8/2024 Buildout year:2031 Growth Rate:3.8%1.0% PSCF:1.00 PHF 0.86 Adjusted PHF 0.92 ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr 2/8/2024 1 20 634 0 0 0 848 0 0 0 0 0 0 55 0 51 PSCF 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Adjusted Volumes 21 634 0 0 848 0 0 0 0 55 0 51 Growth Rate 3.8% 3.8% 3.8%3.8% 3.8% 3.8%3.8% 3.8% 3.8%3.8% 3.8% 3.8% 2031 Growth 7 220 0 0 295 0 0 0 0 19 0 18 Growth 3.8%28 854 0 0 1143 0 0 0 0 74 0 69 Growth Rate 1.0% 1.0% 1.0%1.0% 1.0% 1.0%1.0% 1.0% 1.0%1.0% 1.0% 1.0% 2031 Growth 2 53 0 0 70 0 0 0 0 5 0 4 Growth 1%23 687 0 0 918 0 0 0 0 60 0 55 Committed Projects Publix at Indrio AM IN 65 OUT 53 In/Out In Out Out In %0% 0% 7% 0% 0% 0% 7% 1% 0% 0% 0% 0% 0% 1% 0% 0% Volumes 0 0 5 0 0 0 4 1 0 0 0 0 0 1 0 0 Indrio Woods AM IN 26 OUT 89 In/Out %0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Sabal Palm Grove AM IN 11 OUT 34 In/Out %0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Cabo Rio RV Resort AM IN 15 OUT 27 In/Out %0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Indrio & I-95 Development (25%)AM IN 270 OUT 267 Total Project Volumes 0 231 184 54 220 22 183 53 54 22 54 0 Volumes Used (25%)0 0 58 46 0 14 55 6 0 46 13 14 0 6 14 0 Indrio Groves (25%)AM IN 95 OUT 275 In/Out In In Out Out %0% 55% 0% 0% 0% 0% 0% 38% 0% 0% 0% 0% 0% 38% 0% 55% Volumes 0 52 0 0 0 0 0 36 0 0 0 0 0 105 0 151 Bedner Farms (25%)AM IN 83 OUT 130 Volumes 0 32 0 0 0 12 27 33 0 0 0 0 0 73 0 35 Buc-ee's Volumes 0 0 0 96 0 86 0 0 0 506 9 80 0 0 10 0 Total Committed 0 84 62 142 0 112 86 75 0 552 22 94 0 184 24 186 Committed + 1%0 107 749 142 0 112 1004 75 0 552 22 94 0 244 24 241 Weighted T-Factor 2.4% 6.0% 1.0%1.0% 6.0% 1.0%1.0% 1.0% 1.0%2.6% 1.0% 2.5% Growth 3.8% or Committed + 1%107 854 142 112 1143 75 552 22 94 244 24 241 2031 Pre-Development 107 854 142 112 1143 75 552 22 94 244 24 241 Project Volumes 0 0 5 0 0 2 15 9 0 0 0 1 0 3 0 0 Post-Development 0 107 859 142 0 114 1158 84 0 552 22 95 0 247 24 241 % Trucks ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr Existing 0 21 634 0 0 0 848 0 0 0 0 0 0 55 0 51 Pre-Development 0 107 854 142 0 112 1143 75 0 552 22 94 0 244 24 241 Post-Development 0 107 859 142 0 114 1158 84 0 552 22 95 0 247 24 241 0.9% Peak Hour Traffic Volume Maximum Peak Hour Traffic Volume 6.9%7.0%0.0% Koblegard Rd Indrio Rd Peak Hour Traffic Volume EXHIBIT 1I Club at Indrio Creek Page 243 of 456 HCM 7th Signalized Intersection Summary 2025 Existing AM 5: Indrio Rd & Koblegard Rd 09/30/2025 Club at Indrio Creek 2025 Existing AM 12:29 pm 09/22/2025 Baseline Synchro 12 Report MEP Page 4 Movement EBL EBT EBR WBL WBT WBR NBL NBT NBR SBL SBT SBR Lane Configurations Traffic Volume (veh/h) 21 634 0 0 848 0 0 0 0 55 0 51 Future Volume (veh/h) 21 634 0 0 848 0 0 0 0 55 0 51 Initial Q (Qb), veh 0 0 0 0 0 0 0 0 0 Lane Width Adj. 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Ped-Bike Adj(A_pbT) 1.00 1.00 1.00 1.00 1.00 1.00 Parking Bus, Adj 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Work Zone On Approach No No No Adj Sat Flow, veh/h/ln 1856 1811 0 1885 1811 1885 1856 1885 1856 Adj Flow Rate, veh/h 23 689 0 0 922 0 60 0 6 Peak Hour Factor 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 Percent Heavy Veh, % 3 6 0 1 6 1 3 1 3 Cap, veh/h 98 2042 0 5 1564 726 237 0 300 Arrive On Green 0.03 0.59 0.00 0.00 0.45 0.00 0.07 0.00 0.07 Sat Flow, veh/h 3428 3532 0 1795 3441 1598 3534 0 3145 Grp Volume(v), veh/h 23 689 0 0 922 0 60 0 6 Grp Sat Flow(s),veh/h/ln 1714 1721 0 1795 1721 1598 1767 0 1572 Q Serve(g_s), s 0.2 3.7 0.0 0.0 7.2 0.0 0.6 0.0 0.1 Cycle Q Clear(g_c), s 0.2 3.7 0.0 0.0 7.2 0.0 0.6 0.0 0.1 Prop In Lane 1.00 0.00 1.00 1.00 1.00 1.00 Lane Grp Cap(c), veh/h 98 2042 0 5 1564 726 237 0 300 V/C Ratio(X)0.24 0.34 0.00 0.00 0.59 0.00 0.25 0.00 0.02 Avail Cap(c_a), veh/h 757 5909 0 347 5814 2699 2127 0 1983 HCM Platoon Ratio 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Upstream Filter(I) 1.00 1.00 0.00 0.00 1.00 0.00 1.00 0.00 1.00 Uniform Delay (d), s/veh 17.2 3.7 0.0 0.0 7.4 0.0 16.0 0.0 14.8 Incr Delay (d2), s/veh 1.2 0.1 0.0 0.0 0.4 0.0 0.6 0.0 0.0 Initial Q Delay(d3), s/veh 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 %ile BackOfQ(95%),veh/ln 0.2 0.5 0.0 0.0 2.3 0.0 0.4 0.0 0.0 Unsig. Movement Delay, s/veh LnGrp Delay(d), s/veh 18.4 3.8 0.0 0.0 7.7 0.0 16.6 0.0 14.9 LnGrp LOS B A A B B Approach Vol, veh/h 712 922 66 Approach Delay, s/veh 4.3 7.7 16.4 Approach LOS A A B Timer - Assigned Phs 3 4 6 7 8 Phs Duration (G+Y+Rc), s 5.0 24.3 6.9 0.0 29.3 Change Period (Y+Rc), s 4.0 7.8 4.5 4.0 7.8 Max Green Setting (Gmax), s 8.0 61.2 21.8 7.0 62.2 Max Q Clear Time (g_c+I1), s 2.2 9.2 2.6 0.0 5.7 Green Ext Time (p_c), s 0.0 7.2 0.1 0.0 4.9 Intersection Summary HCM 7th Control Delay, s/veh 6.6 HCM 7th LOS A Notes User approved pedestrian interval to be less than phase max green. User approved volume balancing among the lanes for turning movement. Page 244 of 456 HCM 7th Signalized Intersection Summary 2031 Pre-Dev AM 5: Koblegard Rd & Indrio Rd 09/30/2025 Club at Indrio Creek 2031 Pre-Dev AM 12:29 pm 09/22/2025 Baseline Synchro 12 Report MEP Page 4 Movement EBL EBT EBR WBL WBT WBR NBL NBT NBR SBL SBT SBR Lane Configurations Traffic Volume (veh/h) 107 854 142 112 1143 75 552 22 94 244 24 241 Future Volume (veh/h) 107 854 142 112 1143 75 552 22 94 244 24 241 Initial Q (Qb), veh 0 0 0 0 0 0 0 0 0 0 0 0 Lane Width Adj. 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Ped-Bike Adj(A_pbT) 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Parking Bus, Adj 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Work Zone On Approach No No No No Adj Sat Flow, veh/h/ln 1856 1811 1885 1885 1811 1885 1885 1885 1885 1856 1885 1856 Adj Flow Rate, veh/h 116 928 46 122 1242 28 600 24 20 284 0 99 Peak Hour Factor 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 Percent Heavy Veh, % 3 6 1 1 6 1 1 1 1 3 1 3 Cap, veh/h 176 1386 644 153 1502 697 712 385 327 383 0 502 Arrive On Green 0.05 0.40 0.40 0.08 0.44 0.44 0.20 0.20 0.20 0.11 0.00 0.11 Sat Flow, veh/h 3428 3441 1598 1795 3441 1598 3483 1885 1598 3534 0 3145 Grp Volume(v), veh/h 116 928 46 122 1242 28 600 24 20 284 0 99 Grp Sat Flow(s),veh/h/ln 1714 1721 1598 1795 1721 1598 1742 1885 1598 1767 0 1572 Q Serve(g_s), s 3.5 23.0 1.8 7.0 33.2 1.0 17.3 1.1 1.1 8.1 0.0 2.8 Cycle Q Clear(g_c), s 3.5 23.0 1.8 7.0 33.2 1.0 17.3 1.1 1.1 8.1 0.0 2.8 Prop In Lane 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Lane Grp Cap(c), veh/h 176 1386 644 153 1502 697 712 385 327 383 0 502 V/C Ratio(X)0.66 0.67 0.07 0.80 0.83 0.04 0.84 0.06 0.06 0.74 0.00 0.20 Avail Cap(c_a), veh/h 296 1888 877 310 2185 1014 1119 606 513 864 0 931 HCM Platoon Ratio 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Upstream Filter(I) 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 Uniform Delay (d), s/veh 48.6 25.5 19.1 46.8 25.9 16.9 39.9 33.4 33.4 45.1 0.0 38.0 Incr Delay (d2), s/veh 4.1 0.6 0.0 9.2 1.8 0.0 3.5 0.1 0.1 2.9 0.0 0.2 Initial Q Delay(d3), s/veh 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 %ile BackOfQ(95%),veh/ln 2.8 13.7 1.2 6.1 18.6 0.7 11.9 0.9 0.7 6.5 0.0 1.9 Unsig. Movement Delay, s/veh LnGrp Delay(d), s/veh 52.7 26.0 19.2 56.1 27.7 16.9 43.4 33.5 33.5 47.9 0.0 38.2 LnGrp LOS D C B E C B D C C D D Approach Vol, veh/h 1090 1392 644 383 Approach Delay, s/veh 28.6 30.0 42.7 45.4 Approach LOS C C D D Timer - Assigned Phs 2 3 4 6 7 8 Phs Duration (G+Y+Rc), s 25.8 9.4 53.3 15.8 12.9 49.8 Change Period (Y+Rc), s 4.5 4.0 7.8 4.5 4.0 7.8 Max Green Setting (Gmax), s 33.5 9.0 66.2 25.5 18.0 57.2 Max Q Clear Time (g_c+I1), s 19.3 5.5 35.2 10.1 9.0 25.0 Green Ext Time (p_c), s 2.1 0.1 10.3 1.2 0.2 7.1 Intersection Summary HCM 7th Control Delay, s/veh 33.6 HCM 7th LOS C Notes User approved pedestrian interval to be less than phase max green. User approved volume balancing among the lanes for turning movement. Page 245 of 456 HCM 7th Signalized Intersection Summary 2031 Post-Dev AM 5: Koblegard Rd & Indrio Rd 09/30/2025 Club at Indrio Creek 2031 Post-Dev AM 12:29 pm 09/22/2025 Baseline Synchro 12 Report MEP Page 4 Movement EBL EBT EBR WBL WBT WBR NBL NBT NBR SBL SBT SBR Lane Configurations Traffic Volume (veh/h) 107 859 142 114 1158 84 552 22 95 247 24 241 Future Volume (veh/h) 107 859 142 114 1158 84 552 22 95 247 24 241 Initial Q (Qb), veh 0 0 0 0 0 0 0 0 0 0 0 0 Lane Width Adj. 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Ped-Bike Adj(A_pbT) 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Parking Bus, Adj 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Work Zone On Approach No No No No Adj Sat Flow, veh/h/ln 1856 1811 1885 1885 1811 1885 1885 1885 1885 1856 1885 1856 Adj Flow Rate, veh/h 116 934 45 124 1259 37 600 24 21 287 0 99 Peak Hour Factor 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 Percent Heavy Veh, % 3 6 1 1 6 1 1 1 1 3 1 3 Cap, veh/h 175 1397 649 154 1517 704 710 384 326 383 0 502 Arrive On Green 0.05 0.41 0.41 0.09 0.44 0.44 0.20 0.20 0.20 0.11 0.00 0.11 Sat Flow, veh/h 3428 3441 1598 1795 3441 1598 3483 1885 1598 3534 0 3145 Grp Volume(v), veh/h 116 934 45 124 1259 37 600 24 21 287 0 99 Grp Sat Flow(s),veh/h/ln 1714 1721 1598 1795 1721 1598 1742 1885 1598 1767 0 1572 Q Serve(g_s), s 3.5 23.5 1.8 7.2 34.3 1.4 17.6 1.1 1.1 8.4 0.0 2.9 Cycle Q Clear(g_c), s 3.5 23.5 1.8 7.2 34.3 1.4 17.6 1.1 1.1 8.4 0.0 2.9 Prop In Lane 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Lane Grp Cap(c), veh/h 175 1397 649 154 1517 704 710 384 326 383 0 502 V/C Ratio(X)0.66 0.67 0.07 0.80 0.83 0.05 0.85 0.06 0.06 0.75 0.00 0.20 Avail Cap(c_a), veh/h 291 1886 876 304 2178 1011 1099 595 504 816 0 887 HCM Platoon Ratio 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Upstream Filter(I) 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 Uniform Delay (d), s/veh 49.5 25.7 19.3 47.6 26.2 17.0 40.7 34.1 34.1 45.9 0.0 38.7 Incr Delay (d2), s/veh 4.2 0.6 0.0 9.3 1.9 0.0 3.8 0.1 0.1 3.0 0.0 0.2 Initial Q Delay(d3), s/veh 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 %ile BackOfQ(95%),veh/ln 2.8 14.0 1.2 6.3 19.2 0.9 12.1 0.9 0.8 6.7 0.0 2.0 Unsig. Movement Delay, s/veh LnGrp Delay(d), s/veh 53.7 26.3 19.3 56.9 28.1 17.0 44.4 34.2 34.2 48.9 0.0 38.9 LnGrp LOS D C B E C B D C C D D Approach Vol, veh/h 1095 1420 645 386 Approach Delay, s/veh 28.9 30.3 43.7 46.3 Approach LOS C C D D Timer - Assigned Phs 2 3 4 6 7 8 Phs Duration (G+Y+Rc), s 26.1 9.4 54.6 16.0 13.1 50.9 Change Period (Y+Rc), s 4.5 4.0 7.8 4.5 4.0 7.8 Max Green Setting (Gmax), s 33.5 9.0 67.2 24.5 18.0 58.2 Max Q Clear Time (g_c+I1), s 19.6 5.5 36.3 10.4 9.2 25.5 Green Ext Time (p_c), s 2.0 0.1 10.5 1.1 0.2 7.1 Intersection Summary HCM 7th Control Delay, s/veh 34.1 HCM 7th LOS C Notes User approved pedestrian interval to be less than phase max green. User approved volume balancing among the lanes for turning movement. Page 246 of 456 PM PEAK HOUR TURNING MOVEMENTS & Count Taken:2/7/2024 ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr totals 4:00 PM 4:15 PM 2 18 161 0 0 0 141 0 0 0 0 0 0 17 0 6 345 4:15 PM 4:30 PM 0 12 177 0 0 0 160 0 0 0 0 0 0 16 0 6 371 4:30 PM 4:45 PM 0 13 209 0 0 0 179 0 0 0 0 0 0 22 0 19 442 4:45 PM 5:00 PM 1 14 206 0 0 0 153 0 0 0 0 0 0 20 0 10 404 5:00 PM 5:15 PM 0 12 222 0 2 0 166 0 0 0 0 0 0 18 0 9 429 5:15 PM 5:30 PM 1 13 190 0 0 0 169 0 0 0 0 0 0 16 0 10 399 5:30 PM 5:45 PM 1 13 209 0 0 0 149 0 0 0 0 0 0 17 0 15 404 5:45 PM 6:00 PM 0 3 141 0 0 0 141 0 0 0 0 0 0 16 0 18 319 5 98 1515 0 2 0 1258 0 0 0 0 0 0 142 0 93 3113 4:30 PM 5:30 PM 2 52 827 0 2 0 667 0 0 0 0 0 0 76 0 48 1674 Count Taken:2/8/2024 ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr totals 4:00 PM 4:15 PM 0 11 184 0 0 0 161 0 0 0 0 0 0 12 0 6 374 4:15 PM 4:30 PM 0 12 183 0 0 0 148 0 0 0 0 0 0 11 0 9 363 4:30 PM 4:45 PM 0 16 198 0 0 0 181 0 0 0 0 0 0 24 0 5 424 4:45 PM 5:00 PM 0 9 210 0 0 0 169 0 0 0 0 0 0 18 0 4 410 5:00 PM 5:15 PM 0 7 216 0 0 0 172 0 0 0 0 0 0 14 0 2 411 5:15 PM 5:30 PM 0 9 219 0 0 0 183 0 0 0 0 0 0 13 0 4 428 5:30 PM 5:45 PM 0 9 173 0 0 0 165 0 0 0 0 0 0 15 0 6 368 5:45 PM 6:00 PM 0 11 150 0 0 0 124 0 0 0 0 0 0 18 0 4 307 0 84 1533 0 0 0 1303 0 0 0 0 0 0 125 0 40 3085 4:30 PM 5:30 PM 0 41 843 0 0 0 705 0 0 0 0 0 0 69 0 15 1673 4:30 PM 5:30 PM 2 52 827 0 2 0 667 0 0 0 0 0 0 76 0 48 1674 Count Taken:2/8/2024 Buildout year:2031 Growth Rate:3.8%1.0% PSCF:1.00 PHF 0.95 Adjusted PHF 0.95 ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr 2/8/2024 2 52 827 0 2 0 667 0 0 0 0 0 0 76 0 48 PSCF 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Adjusted Volumes 54 827 0 2 667 0 0 0 0 76 0 48 Growth Rate 3.8% 3.8% 3.8%3.8% 3.8% 3.8%3.8% 3.8% 3.8%3.8% 3.8% 3.8% 2031 Growth 19 288 0 1 232 0 0 0 0 26 0 17 Growth 3.8%73 1115 0 3 899 0 0 0 0 102 0 65 Growth Rate 1.0% 1.0% 1.0%1.0% 1.0% 1.0%1.0% 1.0% 1.0%1.0% 1.0% 1.0% 2031 Growth 4 69 0 0 55 0 0 0 0 6 0 4 Growth 1%58 896 0 2 722 0 0 0 0 82 0 52 Committed Projects Publix at Indrio PM IN 136 OUT 142 In/Out In Out Out In %0% 0% 7% 0% 0% 0% 7% 1% 0% 0% 0% 0% 0% 1% 0% 0% Volumes 0 0 10 0 0 0 10 1 0 0 0 0 0 1 0 0 Indrio Woods PM IN 69 OUT 44 In/Out %0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Sabal Palm Grove PM IN 32 OUT 22 In/Out %0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Cabo Rio RV Resort PM IN 36 OUT 19 In/Out %0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Indrio & I-95 Development (25%)PM IN 373 OUT 386 Total Project Volumes 0 344 254 75 346 31 268 77 78 30 74 0 Volumes Used (25%)0 0 86 64 0 19 87 8 0 67 19 20 0 8 19 0 Indrio Groves (25%)PM IN 335 OUT 197 In/Out In In Out Out %0% 55% 0% 0% 0% 0% 0% 38% 0% 0% 0% 0% 0% 38% 0% 55% Volumes 0 184 0 0 0 0 0 127 0 0 0 0 0 75 0 108 Bedner Farms (25%)PM IN 204 OUT 173 Volumes 0 80 0 0 0 6 63 78 0 0 0 0 0 119 0 36 Buc-ee's Volumes 0 0 0 122 0 109 0 0 0 693 12 110 0 0 12 0 Total Committed 0 264 96 186 0 134 159 214 0 760 31 130 0 203 31 144 Committed + 1%0 322 992 186 0 136 881 214 0 760 31 130 0 285 31 196 Weighted T-Factor 1.9% 4.7% 1.0%1.1% 4.8% 1.0%1.0% 1.0% 1.0%2.4% 1.0% 2.3% Growth 3.8% or Committed + 1%322 1115 186 136 899 214 760 31 130 285 31 196 2031 Pre-Development 322 1115 186 136 899 214 760 31 130 285 31 196 Project Volumes 0 0 16 0 0 1 10 6 0 0 0 2 0 9 0 0 Post-Development 0 322 1131 186 0 137 909 220 0 760 31 132 0 294 31 196 % Trucks ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr Existing 0 54 827 0 0 2 667 0 0 0 0 0 0 76 0 48 Pre-Development 0 322 1115 186 0 136 899 214 0 760 31 130 0 285 31 196 Post-Development 0 322 1131 186 0 137 909 220 0 760 31 132 0 294 31 196 1.2% EXHIBIT 1J Koblegard Rd Indrio Rd Peak Hour Traffic Volume Peak Hour Traffic Volume Club at Indrio Creek Maximum Peak Hour Traffic Volume 5.2%3.1%0.0% Page 247 of 456 HCM 7th Signalized Intersection Summary 2025 Existing PM 5: Indrio Rd & Koblegard Rd 09/30/2025 Club at Indrio Creek 2025 Existing PM 12:29 pm 09/22/2025 Baseline Synchro 12 Report MEP Page 4 Movement EBL EBT EBR WBL WBT WBR NBL NBT NBR SBL SBT SBR Lane Configurations Traffic Volume (veh/h) 54 827 0 2 667 0 0 0 0 76 0 48 Future Volume (veh/h) 54 827 0 2 667 0 0 0 0 76 0 48 Initial Q (Qb), veh 0 0 0 0 0 0 0 0 0 Lane Width Adj. 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Ped-Bike Adj(A_pbT) 1.00 1.00 1.00 1.00 1.00 1.00 Parking Bus, Adj 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Work Zone On Approach No No No Adj Sat Flow, veh/h/ln 1870 1826 0 1870 1826 1885 1856 1885 1856 Adj Flow Rate, veh/h 57 871 0 2 702 0 80 0 9 Peak Hour Factor 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 Percent Heavy Veh, % 2 5 0 2 5 1 3 1 3 Cap, veh/h 211 1528 0 5 1326 611 294 0 454 Arrive On Green 0.06 0.44 0.00 0.00 0.38 0.00 0.08 0.00 0.08 Sat Flow, veh/h 3456 3561 0 1781 3469 1598 3534 0 3145 Grp Volume(v), veh/h 57 871 0 2 702 0 80 0 9 Grp Sat Flow(s),veh/h/ln 1728 1735 0 1781 1735 1598 1767 0 1572 Q Serve(g_s), s 0.5 6.5 0.0 0.0 5.4 0.0 0.7 0.0 0.1 Cycle Q Clear(g_c), s 0.5 6.5 0.0 0.0 5.4 0.0 0.7 0.0 0.1 Prop In Lane 1.00 0.00 1.00 1.00 1.00 1.00 Lane Grp Cap(c), veh/h 211 1528 0 5 1326 611 294 0 454 V/C Ratio(X)0.27 0.57 0.00 0.39 0.53 0.00 0.27 0.00 0.02 Avail Cap(c_a), veh/h 1104 6973 0 466 6772 3118 2515 0 2430 HCM Platoon Ratio 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Upstream Filter(I) 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 1.00 Uniform Delay (d), s/veh 15.4 7.2 0.0 17.1 8.2 0.0 14.8 0.0 12.6 Incr Delay (d2), s/veh 0.7 0.3 0.0 41.2 0.3 0.0 0.5 0.0 0.0 Initial Q Delay(d3), s/veh 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 %ile BackOfQ(95%),veh/ln 0.3 2.0 0.0 0.1 2.0 0.0 0.4 0.0 0.0 Unsig. Movement Delay, s/veh LnGrp Delay(d), s/veh 16.1 7.5 0.0 58.3 8.6 0.0 15.3 0.0 12.7 LnGrp LOS B A E A B B Approach Vol, veh/h 928 704 89 Approach Delay, s/veh 8.1 8.7 15.0 Approach LOS A A B Timer - Assigned Phs 3 4 6 7 8 Phs Duration (G+Y+Rc), s 6.1 21.0 7.4 4.1 23.0 Change Period (Y+Rc), s 4.0 7.8 4.5 4.0 7.8 Max Green Setting (Gmax), s 11.0 67.2 24.5 9.0 69.2 Max Q Clear Time (g_c+I1), s 2.5 7.4 2.7 2.0 8.5 Green Ext Time (p_c), s 0.1 5.0 0.2 0.0 6.7 Intersection Summary HCM 7th Control Delay, s/veh 8.7 HCM 7th LOS A Notes User approved pedestrian interval to be less than phase max green. User approved volume balancing among the lanes for turning movement. Page 248 of 456 HCM 7th Signalized Intersection Summary 2031 Pre-Dev PM 5: Indrio Rd & Koblegard Rd 09/30/2025 Club at Indrio Creek 2031 Pre-Dev PM 12:29 pm 09/22/2025 Baseline Synchro 12 Report MEP Page 4 Movement EBL EBT EBR WBL WBT WBR NBL NBT NBR SBL SBT SBR Lane Configurations Traffic Volume (veh/h) 322 1115 186 136 899 214 760 31 130 285 31 196 Future Volume (veh/h) 322 1115 186 136 899 214 760 31 130 285 31 196 Initial Q (Qb), veh 0 0 0 0 0 0 0 0 0 0 0 0 Lane Width Adj. 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Ped-Bike Adj(A_pbT) 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Parking Bus, Adj 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Work Zone On Approach No No No No Adj Sat Flow, veh/h/ln 1870 1826 1885 1870 1826 1885 1885 1885 1885 1856 1885 1856 Adj Flow Rate, veh/h 339 1174 58 143 946 73 800 33 32 324 0 127 Peak Hour Factor 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 Percent Heavy Veh, % 2 5 1 2 5 1 1 1 1 3 1 3 Cap, veh/h 396 1327 611 168 1256 578 888 480 407 395 0 712 Arrive On Green 0.11 0.38 0.38 0.09 0.36 0.36 0.25 0.25 0.25 0.11 0.00 0.11 Sat Flow, veh/h 3456 3469 1598 1781 3469 1598 3483 1885 1598 3534 0 3145 Grp Volume(v), veh/h 339 1174 58 143 946 73 800 33 32 324 0 127 Grp Sat Flow(s),veh/h/ln 1728 1735 1598 1781 1735 1598 1742 1885 1598 1767 0 1572 Q Serve(g_s), s 12.8 41.9 3.1 10.5 31.8 4.1 29.5 1.8 2.0 11.9 0.0 4.3 Cycle Q Clear(g_c), s 12.8 41.9 3.1 10.5 31.8 4.1 29.5 1.8 2.0 11.9 0.0 4.3 Prop In Lane 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Lane Grp Cap(c), veh/h 396 1327 611 168 1256 578 888 480 407 395 0 712 V/C Ratio(X)0.86 0.88 0.09 0.85 0.75 0.13 0.90 0.07 0.08 0.82 0.00 0.18 Avail Cap(c_a), veh/h 487 1526 703 201 1429 658 1057 572 485 546 0 846 HCM Platoon Ratio 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Upstream Filter(I) 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 Uniform Delay (d), s/veh 57.7 38.3 26.3 59.2 37.1 28.3 47.9 37.5 37.6 57.7 0.0 41.4 Incr Delay (d2), s/veh 11.9 6.0 0.1 24.6 2.0 0.1 9.4 0.1 0.1 7.0 0.0 0.1 Initial Q Delay(d3), s/veh 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 %ile BackOfQ(95%),veh/ln10.2 25.1 2.1 9.7 19.3 2.8 19.6 1.5 1.4 9.5 0.0 3.0 Unsig. Movement Delay, s/veh LnGrp Delay(d), s/veh 69.6 44.2 26.3 83.8 39.2 28.4 57.3 37.6 37.7 64.6 0.0 41.5 LnGrp LOS E D C F D C E D D E D Approach Vol, veh/h 1571 1162 865 451 Approach Delay, s/veh 49.0 44.0 55.8 58.1 Approach LOS D D E E Timer - Assigned Phs 2 3 4 6 7 8 Phs Duration (G+Y+Rc), s 38.3 19.2 55.9 19.3 16.5 58.6 Change Period (Y+Rc), s 4.5 4.0 7.8 4.5 4.0 7.8 Max Green Setting (Gmax), s 40.3 18.7 54.7 20.5 15.0 58.4 Max Q Clear Time (g_c+I1), s 31.5 14.8 33.8 13.9 12.5 43.9 Green Ext Time (p_c), s 2.3 0.4 6.5 0.9 0.1 6.9 Intersection Summary HCM 7th Control Delay, s/veh 50.0 HCM 7th LOS D Notes User approved pedestrian interval to be less than phase max green. User approved volume balancing among the lanes for turning movement. Page 249 of 456 HCM 7th Signalized Intersection Summary 2031 Post-Dev PM 5: Koblegard Rd & Indrio Rd 09/30/2025 Club at Indrio Creek 2031 Post-Dev PM 12:29 pm 09/22/2025 Baseline Synchro 12 Report MEP Page 1 Movement EBL EBT EBR WBL WBT WBR NBL NBT NBR SBL SBT SBR Lane Configurations Traffic Volume (veh/h) 322 1131 186 137 909 220 760 31 132 294 31 196 Future Volume (veh/h) 322 1131 186 137 909 220 760 31 132 294 31 196 Initial Q (Qb), veh 0 0 0 0 0 0 0 0 0 0 0 0 Lane Width Adj. 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Ped-Bike Adj(A_pbT) 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Parking Bus, Adj 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Work Zone On Approach No No No No Adj Sat Flow, veh/h/ln 1870 1826 1885 1870 1826 1885 1885 1885 1885 1856 1885 1856 Adj Flow Rate, veh/h 339 1191 54 144 957 79 800 33 34 333 0 74 Peak Hour Factor 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 Percent Heavy Veh, % 2 5 1 2 5 1 1 1 1 3 1 3 Cap, veh/h 395 1347 620 168 1278 589 887 480 407 398 0 714 Arrive On Green 0.11 0.39 0.39 0.09 0.37 0.37 0.25 0.25 0.25 0.11 0.00 0.11 Sat Flow, veh/h 3456 3469 1598 1781 3469 1598 3483 1885 1598 3534 0 3145 Grp Volume(v), veh/h 339 1191 54 144 957 79 800 33 34 333 0 74 Grp Sat Flow(s),veh/h/ln 1728 1735 1598 1781 1735 1598 1742 1885 1598 1767 0 1572 Q Serve(g_s), s 13.4 44.4 3.0 11.0 33.4 4.6 30.8 1.8 2.2 12.8 0.0 2.6 Cycle Q Clear(g_c), s 13.4 44.4 3.0 11.0 33.4 4.6 30.8 1.8 2.2 12.8 0.0 2.6 Prop In Lane 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Lane Grp Cap(c), veh/h 395 1347 620 168 1278 589 887 480 407 398 0 714 V/C Ratio(X)0.86 0.88 0.09 0.86 0.75 0.13 0.90 0.07 0.08 0.84 0.00 0.10 Avail Cap(c_a), veh/h 493 1570 723 218 1500 691 1077 583 494 548 0 847 HCM Platoon Ratio 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Upstream Filter(I) 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 Uniform Delay (d), s/veh 60.3 39.5 26.9 61.9 38.2 29.1 50.0 39.2 39.4 60.3 0.0 42.5 Incr Delay (d2), s/veh 11.9 5.7 0.1 22.0 1.8 0.1 9.2 0.1 0.1 8.0 0.0 0.1 Initial Q Delay(d3), s/veh 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 %ile BackOfQ(95%),veh/ln10.5 26.4 2.0 9.9 20.2 3.1 20.4 1.5 1.6 10.1 0.0 1.8 Unsig. Movement Delay, s/veh LnGrp Delay(d), s/veh 72.2 45.3 26.9 83.9 40.0 29.2 59.2 39.3 39.5 68.3 0.0 42.5 LnGrp LOS E D C F D C E D D E D Approach Vol, veh/h 1584 1180 867 407 Approach Delay, s/veh 50.4 44.6 57.7 63.6 Approach LOS D D E E Timer - Assigned Phs 2 3 4 6 7 8 Phs Duration (G+Y+Rc), s 39.8 19.9 58.9 20.1 17.1 61.7 Change Period (Y+Rc), s 4.5 4.0 7.8 4.5 4.0 7.8 Max Green Setting (Gmax), s 42.9 19.8 60.0 21.5 17.0 62.8 Max Q Clear Time (g_c+I1), s 32.8 15.4 35.4 14.8 13.0 46.4 Green Ext Time (p_c), s 2.5 0.5 7.0 0.8 0.1 7.5 Intersection Summary HCM 7th Control Delay, s/veh 51.6 HCM 7th LOS D Notes User approved pedestrian interval to be less than phase max green. User approved volume balancing among the lanes for turning movement. Page 250 of 456 AM PEAK HOUR TURNING MOVEMENTS & Count Taken:2/7/2024 ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr totals7:00 AM 7:15 AM 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 7:15 AM 7:30 AM 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 1 7:30 AM 7:45 AM 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 7:45 AM 8:00 AM 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 08:00 AM 8:15 AM 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 1 8:15 AM 8:30 AM 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 8:30 AM 8:45 AM 0 0 0 0 0 0 0 0 0 0 1 0 0 0 1 0 2 8:45 AM 9:00 AM 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 10 0 0 0 0 0 0 0 0 0 3 0 0 0 2 0 5 8:00 AM 9:00 AM 0 0 0 0 0 0 0 0 0 0 2 0 0 0 2 0 4 Count Taken:2/8/2024 ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr totals 7:00 AM 7:15 AM 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 1 7:15 AM 7:30 AM 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 07:30 AM 7:45 AM 0 0 0 0 0 0 0 0 0 0 1 0 0 0 2 0 3 7:45 AM 8:00 AM 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 1 8:00 AM 8:15 AM 0 0 0 0 0 0 0 0 0 0 1 0 0 0 1 0 2 8:15 AM 8:30 AM 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 8:30 AM 8:45 AM 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 18:45 AM 9:00 AM 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 0 0 0 4 0 8 EXCEPTION #VALUE!0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 8:00 AM 9:00 AM 0 0 0 0 0 0 0 0 0 0 2 0 0 0 2 0 4 Count Taken:2/8/2024 Buildout year:2031 Growth Rate:3.8%1.0%PSCF:1.00 PHF 0.50 Adjusted PHF 0.92 ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr 2/8/2024 0 0 0 0 0 0 0 0 0 0 2 0 0 0 2 0 PSCF 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Adjusted Volumes 0 0 0 0 0 0 0 2 0 0 2 0 Growth Rate 3.8% 3.8% 3.8%3.8% 3.8% 3.8%3.8% 3.8% 3.8%3.8% 3.8% 3.8% 2031 Growth 0 0 0 0 0 0 0 1 0 0 1 0Growth 3.8%0 0 0 0 0 0 0 3 0 0 3 0 Growth Rate 1.0% 1.0% 1.0%1.0% 1.0% 1.0%1.0% 1.0% 1.0%1.0% 1.0% 1.0% 2031 Growth 0 0 0 0 0 0 0 0 0 0 0 0 Growth 1%0 0 0 0 0 0 0 2 0 0 2 0 Committed ProjectsPublix at Indrio AM IN 65 OUT 53 In/Out % Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Indrio Woods AM IN 26 OUT 89 In/Out % Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Sabal Palm Grove AM IN 11 OUT 34 In/Out % Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Cabo Rio RV Resort AM IN 15 OUT 27In/Out % Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Indrio & I-95 Development (25%)AM IN 270 OUT 267In/Out % Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Indrio Groves (25%)AM IN 95 OUT 275In/Out % Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Bedner Farms (25%)AM IN 83 OUT 130In/Out % Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Eagle Bend (25%)AM In 52 Out 158In/Out % Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4540 N Kings Hwy (25%)AM IN 10 OUT 29In/Out in %8% Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 Buc-ee's AM IN 610 OUT 570 In/Out% Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Indrio Townhomes (25%) Total Committed 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 Committed + 1%0 0 0 0 0 0 0 0 0 0 2 0 0 0 3 0 Growth 3.8% or Committed + 1%0 0 0 0 0 0 0 3 0 0 3 0 2031 Pre-Development 0 0 0 0 0 0 0 3 0 0 3 0 Project Volumes 0 0 0 0 0 170 0 0 0 60 0 0 Post-Development 0 0 0 0 0 170 0 3 0 60 3 0 % Trucks Out In 0% 0% 0% 0% 0% 0% 0% 100% 0% 0% 0% 0% 0% 100% 0% 0% ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr Existing 0 0 0 0 0 0 0 0 0 0 2 0 0 0 2 0 Pre-Development 0 0 0 0 0 0 0 0 0 0 3 0 0 0 3 0Post-Development 0 0 0 0 0 0 0 170 0 0 3 0 0 60 3 0 Club at Indrio Creek Peak Hour Traffic Volume EXHIBIT 1K Emerson Avenue Driveway 1 Peak Hour Traffic Volume Maximum Peak Hour Traffic Volume 8.9%7.3%0.0%4.7% Assignment Page 251 of 456 HCM 7th TWSC 2031 Post-Dev AM 6: Emerson Ave & Driveway 1 09/30/2025 Club at Indrio Creek 2031 Post-Dev AM 12:29 pm 09/22/2025 Baseline Synchro 12 Report MEP Page 2 Intersection Int Delay, s/veh 8.4 Movement WBL WBR NBT NBR SBL SBT Lane Configurations Traffic Vol, veh/h 0 170 3 0 60 3 Future Vol, veh/h 0 170 3 0 60 3 Conflicting Peds, #/hr 0 0 0 0 0 0 Sign Control Stop Stop Free Free Free Free RT Channelized - None - None - None Storage Length - - - - - - Veh in Median Storage, #0 - 0 - - 0 Grade, %0 - 0 - - 0 Peak Hour Factor 92 92 92 92 92 92 Heavy Vehicles, % 2 2 2 2 2 2 Mvmt Flow 0 185 3 0 65 3 Major/Minor Minor1 Major1 Major2 Conflicting Flow All 137 3 0 0 3 0 Stage 1 3 - - - - - Stage 2 134 - - - - - Critical Hdwy 6.42 6.22 - - 4.12 - Critical Hdwy Stg 1 5.42 - - - - - Critical Hdwy Stg 2 5.42 - - - - - Follow-up Hdwy 3.5183.318 - -2.218 - Pot Cap-1 Maneuver856 1081 - - 1619 - Stage 1 1020 - - - - - Stage 2 893 - - - - - Platoon blocked, %- - - Mov Cap-1 Maneuver822 1081 - - 1619 - Mov Cap-2 Maneuver822 - - - - - Stage 1 1020 - - - - - Stage 2 857 - - - - - Approach WB NB SB HCM Control Delay, s/v9.02 0 6.97 HCM LOS A Minor Lane/Major Mvmt NBT NBRWBLn1 SBL SBT Capacity (veh/h)- - 1081 1619 - HCM Lane V/C Ratio - -0.171 0.04 - HCM Control Delay (s/veh) - - 9 7.3 - HCM Lane LOS - - A A - HCM 95th %tile Q(veh) - - 0.6 0.1 - Page 252 of 456 PM PEAK HOUR TURNING MOVEMENTS & Count Taken:2/7/2024 ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr totals 4:00 PM 4:15 PM 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 1 4:15 PM 4:30 PM 0 0 0 0 0 0 0 0 0 0 1 0 0 0 2 0 3 4:30 PM 4:45 PM 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 1 4:45 PM 5:00 PM 0 0 0 0 0 0 0 0 0 0 1 0 0 0 1 0 2 5:00 PM 5:15 PM 0 0 0 0 0 0 0 0 0 0 1 0 0 0 2 0 35:15 PM 5:30 PM 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 05:30 PM 5:45 PM 0 0 0 0 0 0 0 0 0 0 2 0 0 0 0 0 2 5:45 PM 6:00 PM 0 0 0 0 0 0 0 0 0 0 1 0 0 0 1 0 2 0 0 0 0 0 0 0 0 0 0 8 0 0 0 6 0 14 4:15 PM 5:15 PM 0 0 0 0 0 0 0 0 0 0 4 0 0 0 5 0 9 Count Taken:2/8/2024 ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr totals4:00 PM 4:15 PM 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 14:15 PM 4:30 PM 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 1 4:30 PM 4:45 PM 0 0 0 0 0 0 0 0 0 0 2 0 0 0 1 0 3 4:45 PM 5:00 PM 0 0 0 0 0 0 0 0 0 0 1 0 0 0 1 0 2 5:00 PM 5:15 PM 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 5:15 PM 5:30 PM 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 1 5:30 PM 5:45 PM 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 5:45 PM 6:00 PM 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 4 0 0 0 4 0 8 4:00 PM 5:00 PM 0 0 0 0 0 0 0 0 0 0 4 0 0 0 3 0 7 4:15 PM 5:15 PM 0 0 0 0 0 0 0 0 0 0 4 0 0 0 5 0 9 Count Taken:2/7/2024Buildout year:2031Growth Rate:3.8%1.0% PSCF:1.00 PHF 0.75 Adjusted PHF 0.92 ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr 2/7/2024 0 0 0 0 0 0 0 0 0 0 4 0 0 0 5 0 PSCF 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Adjusted Volumes 0 0 0 0 0 0 0 4 0 0 5 0 Growth Rate 3.8% 3.8% 3.8%3.8% 3.8% 3.8%3.8% 3.8% 3.8%3.8% 3.8% 3.8%2031 Growth 0 0 0 0 0 0 0 1 0 0 2 0Growth 3.8%0 0 0 0 0 0 0 5 0 0 7 0 Growth Rate 1.0% 1.0% 1.0%1.0% 1.0% 1.0%1.0% 1.0% 1.0%1.0% 1.0% 1.0%2031 Growth 0 0 0 0 0 0 0 0 0 0 0 0Growth 1%0 0 0 0 0 0 0 4 0 0 5 0Committed Projects Publix at Indrio PM IN 136 OUT 142 In/Out % Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Indrio Woods PM IN 69 OUT 44 In/Out%Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Sabal Palm Grove PM IN 32 OUT 22 In/Out % Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Cabo Rio RV Resort PM IN 36 OUT 19 In/Out%Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Indrio & I-95 Development (25%)PM IN 373 OUT 386 In/Out % Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Indrio Groves (25%)PM IN 335 OUT 197 In/Out%Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Bedner Farms (25%)PM IN 204 OUT 173 In/Out % Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Eagle Bend (25%)PM In 185 Out 109 In/Out %Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 04540 N Kings Hwy (25%)PM IN 32 OUT 19 In/Out in %8% Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 0 Buc-ee's PM IN 772 OUT 786 In/Out %Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Indrio Townhomes (25%) Total Committed 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 0Committed + 1%0 0 0 0 0 0 0 0 0 0 4 0 0 0 8 0 Growth 3.8% or Committed + 1%0 0 0 0 0 0 0 5 0 0 8 0 2031 Pre-Development 0 0 0 0 0 0 0 5 0 0 8 0 Project Volumes 0 0 0 0 0 111 0 0 0 182 0 0 Post-Development 0 0 0 0 0 111 0 5 0 182 8 0 % Trucks Out In 0% 0% 0% 0% 0% 0% 0% 100% 0% 0% 0% 0% 0% 100% 0% 0% ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr Existing 0 0 0 0 0 0 0 0 0 0 4 0 0 0 5 0Pre-Development 0 0 0 0 0 0 0 0 0 0 5 0 0 0 8 0Post-Development 0 0 0 0 0 0 0 111 0 0 5 0 0 182 8 0 Peak Hour Traffic Volume Club at Indrio Creek EXHIBIT 1LEmerson Avenue Driveway 1 Peak Hour Traffic Volume Maximum Peak Hour Traffic Volume 3.3%2.6%0.0%3.4% Assignment Page 253 of 456 HCM 7th TWSC 2031 Post-Dev PM 6: Emerson Ave & Driveway 1 09/30/2025 Club at Indrio Creek 2031 Post-Dev PM 12:29 pm 09/22/2025 Baseline Synchro 12 Report MEP Page 2 Intersection Int Delay, s/veh 7.9 Movement WBL WBR NBT NBR SBL SBT Lane Configurations Traffic Vol, veh/h 0 111 5 0 182 0 Future Vol, veh/h 0 111 5 0 182 0 Conflicting Peds, #/hr 0 0 0 0 0 0 Sign Control Stop Stop Free Free Free Free RT Channelized - None - None - None Storage Length - - - - - - Veh in Median Storage, #0 - 0 - - 0 Grade, %0 - 0 - - 0 Peak Hour Factor 92 92 92 92 92 92 Heavy Vehicles, % 2 2 2 2 2 2 Mvmt Flow 0 121 5 0 198 0 Major/Minor Minor1 Major1 Major2 Conflicting Flow All 401 5 0 0 5 0 Stage 1 5 - - - - - Stage 2 396 - - - - - Critical Hdwy 6.42 6.22 - - 4.12 - Critical Hdwy Stg 1 5.42 - - - - - Critical Hdwy Stg 2 5.42 - - - - - Follow-up Hdwy 3.5183.318 - -2.218 - Pot Cap-1 Maneuver605 1078 - - 1616 - Stage 1 1018 - - - - - Stage 2 680 - - - - - Platoon blocked, %- - - Mov Cap-1 Maneuver531 1078 - - 1616 - Mov Cap-2 Maneuver531 - - - - - Stage 1 1018 - - - - - Stage 2 597 - - - - - Approach WB NB SB HCM Control Delay, s/v8.76 0 7.54 HCM LOS A Minor Lane/Major Mvmt NBT NBRWBLn1 SBL SBT Capacity (veh/h)- - 1078 1616 - HCM Lane V/C Ratio - - 0.1120.122 - HCM Control Delay (s/veh) - - 8.8 7.5 - HCM Lane LOS - - A A - HCM 95th %tile Q(veh) - - 0.4 0.4 - Page 254 of 456 Arterial Level of Service 2031 Post-Dev PM 09/30/2025 Club at Indrio Creek 2031 Post-Dev PM 12:29 pm 09/22/2025 Baseline Synchro 12 Report MEP Page 1 Arterial Level of Service: EB Indrio Rd Arterial Flow Running Signal Travel Dist Arterial Arterial Cross Street Class Speed Time Delay Time (s) (mi) Speed LOS Koblegard Rd II 45 18.4 57.7 76.1 0.17 8.0 F Johnston Rd II 45 60.8 36.5 97.3 0.76 28.1 B Emerson Ave II 45 80.1 30.3 110.4 1.00 32.6 B Kings Hwy II 35 105.0 37.0 142.0 1.02 25.9 C Total II 264.3 161.5 425.8 2.95 24.9 C Arterial Level of Service: WB Indrio Rd Arterial Flow Running Signal Travel Dist Arterial Arterial Cross Street Class Speed Time Delay Time (s) (mi) Speed LOS Kings Hwy II 25 40.7 52.4 93.1 0.27 10.3 F Emerson Ave II 45 81.6 40.3 121.9 1.02 30.1 B Johnston Rd II 45 80.1 45.6 125.7 1.00 28.7 B Koblegard Rd II 45 60.8 49.5 110.3 0.76 24.8 C Total II 263.2 187.8 451.0 3.05 24.3 C Arterial Level of Service: NB Kings Hwy Arterial Flow Running Signal Travel Dist Arterial Arterial Cross Street Class Speed Time Delay Time (s) (mi) Speed LOS Indrio Rd I 50 183.0 40.6 223.6 2.54 40.9 B Total I 183.0 40.6 223.6 2.54 40.9 B Arterial Level of Service: SB Kings Hwy Arterial Flow Running Signal Travel Dist Arterial Arterial Cross Street Class Speed Time Delay Time (s) (mi) Speed LOS Indrio Rd III 50 33.9 51.5 85.4 0.39 16.6 D Total III 33.9 51.5 85.4 0.39 16.6 D Page 255 of 456 Arterial Level of Service 2031 Post-Dev AM 09/30/2025 Club at Indrio Creek 2031 Post-Dev AM 12:29 pm 09/22/2025 Baseline Synchro 12 Report MEP Page 1 Arterial Level of Service: EB Indrio Rd Arterial Flow Running Signal Travel Dist Arterial Arterial Cross Street Class Speed Time Delay Time (s) (mi) Speed LOS Koblegard Rd II 45 18.4 39.4 57.8 0.17 10.5 F Johnston Rd II 45 60.8 29.8 90.6 0.76 30.2 B Emerson Ave II 45 80.1 26.9 107.0 1.00 33.7 B Kings Hwy II 35 105.0 35.7 140.7 1.02 26.1 C Total II 264.3 131.8 396.1 2.95 26.8 C Arterial Level of Service: WB Indrio Rd Arterial Flow Running Signal Travel Dist Arterial Arterial Cross Street Class Speed Time Delay Time (s) (mi) Speed LOS Kings Hwy II 25 40.7 43.1 83.8 0.27 11.4 F Emerson Ave II 45 81.6 38.4 120.0 1.02 30.6 B Johnston Rd II 45 80.1 41.7 121.8 1.00 29.6 B Koblegard Rd II 45 60.8 42.6 103.4 0.76 26.5 C Total II 263.2 165.8 429.0 3.05 25.6 C Arterial Level of Service: NB Kings Hwy Arterial Flow Running Signal Travel Dist Arterial Arterial Cross Street Class Speed Time Delay Time (s) (mi) Speed LOS Indrio Rd I 50 182.9 30.7 213.6 2.54 42.8 A Total I 182.9 30.7 213.6 2.54 42.8 A Arterial Level of Service: SB Kings Hwy Arterial Flow Running Signal Travel Dist Arterial Arterial Cross Street Class Speed Time Delay Time (s) (mi) Speed LOS Indrio Rd III 50 33.9 36.0 69.9 0.39 20.3 C Total III 33.9 36.0 69.9 0.39 20.3 C Page 256 of 456 Queue (in Feet) Storage (in Feet) Needed Storage (in Feet) Adequate Queue Storage Adequate Queue Storage Needed Storage (in Feet) Adequate Queue Storage Adequate Queue Storage Adequate Queue Storage Adequate Queue Storage Adequate Queue Storage Adequate 2025 Existing 118 YES 55 YES 30 YES 8 YES 85 YES 8 YES 63 YES 40 YES 2031 Pre 230 425 YES 33 YES 70 YES 15 YES 140 YES 8 YES 105 YES 25 YES 2031 Post 248 YES 78 YES 70 YES 15 YES 153 YES 8 YES 105 YES 30 YES 2025 Existing 43 YES 0 YES 3 YES 58 YES 0 YES 48 YES 50 YES 2031 Pre 93 YES 5 YES 3 YES 85 YES 5 YES 93 YES 103 YES 2031 Post 113 YES 20 YES 38 YES 105 YES 55 YES 115 YES 3 YES 2025 Existing 133 YES 5 YES 28 YES 13 YES 13 YES 3 YES 33 YES 28 YES 2031 Pre 213 YES 0.3 YES 90 YES 8 YES 38 YES 3 YES 2.9 YES 23 YES 2031 Post 215 YES 5 YES 113 YES 18 YES 40 YES 5 YES 70 YES 23 YES 2025 Existing 5 YES -0 YES 0 YES --10 YES 0 YES 2031 Pre 70 YES 30 153 YES 18 YES 298 18 163 YES 48 YES 2031 Post 70 YES 30 158 YES 23 YES 303 20 168 YES 50 YES Queue Storage Needed Storage (in Feet) Adequate Queue Storage Adequate Queue Storage Needed Storage (in Feet) Adequate Queue Storage Adequate Queue Storage Adequate Queue Storage Adequate Queue Storage Needed Storage (in Feet) Adequate Queue Storage Adequate 2025 Existing 178 YES 20 YES 70 YES 68 YES 140 YES 33 YES 43 YES 33 YES 2031 Pre 418 425 NO 60 YES 133 YES 15 YES 268 YES 10 YES 85 YES 50 YES 2031 Post 465 NO + 50' 45 YES 145 YES 18 YES 318 YES 13 YES 93 YES 73 YES 2025 Existing 88 YES 0 YES 3 YES 118 YES --38 YES 5 YES 2031 Pre 168 YES 0.3 YES 5 YES 75 YES 0 YES 5.3 YES 13 YES 2031 Post 198 YES 0 YES 125 YES 93 YES 33 YES 128 YES 15 YES 2025 Existing 133 YES 3 YES 28 YES 20 YES 10 YES 3 YES 50 YES 15 YES 2031 Pre 230 YES 5 YES 120 YES 8 YES 50 YES 8 YES 5.8 YES 23 YES 2031 Post 233 YES 5 YES 130 YES 15 YES 50 YES 15 YES 120 YES 23 YES 2025 Existing 8 YES -3 YES 0 YES --10 YES 0 YES 2031 Pre 255 275 NO 53 243 250 NO 70 YES 490 35 238 YES 75 YES 2031 Post 263 YES 50 248 YES 78 YES 510 38 253 YES 45 YES 1 Indrio Road & Kings Highway PeriodNo. Intersection 4 Indrio Road & Johnston Road 3 5 Indrio Road & Koblegard Road 250 275 290Indrio Road & Emerson Avenue 350 180 215 200 350 180 215 200 225 245 250 300 375 425 375 240 350 180 215 200 5 Indrio Road & Koblegard Road 350 180 215 200 350 180- 1 Indrio Road & Kings Highway 3 Indrio Road & Emerson Avenue 4 Indrio Road & Johnston Road 350 180 215 200 250 No. Intersection Period 225 -200 200 --350 350 EBREBL -- - 225 245 250 300 375 425 375 240 WBR NBL NBR SBL SBR - - - SBRSBLNBRNBLWBRWBL 95th Percentile Queue Storage AM Intersection Result 95th Percentile Queue Storage PM Intersection Result Notes: * Pre-Development Improvements with needed storage +XX' - Additional queue caused by Project in excess of storage 215 200 -- 225 200 200 350 350 - EBL - --- - -275 290 EBR WBL * * * Page 257 of 456 1172 SW 30th Street, Suite 500 • Palm City • Florida • 34990 (772) 286-8030• www.mackenzieengineeringinc.com Memorandum To: St. Lucie County Public Works Department From: Shaun G. Mackenzie, P.E. Date: Revised September 18, 2025 Re: The Club at Indrio Creek - Traffic Study Methodology Updates from 8/18/2025 meeting St. Lucie County Acceptance The Club at Indrio Creek Traffic Study Methodology was Approved on ______________________, 20 by __________________________________________ INTRODUCTION MacKenzie Engineering and Planning, Inc. (MEP) was retained by Engineering Design & Construction, Inc. to perform a traffic analysis for The Club at Indrio Creek in St. Lucie County, FL. The proposed project is located at the south of Indrio Road, east of Emerson Avenue, and west of Seminole Road, St. Lucie County, FL (Parcel ID: 1314-323-0002-000-3; 1314-313-0000-000-8; 1314-331-0001-000-1; 1314- 342-0001-000-5 and 1323-211-0005-000-8). Figure 1 illustrates the site location. The buildout year is 2031. The applicant proposes to construct the following uses at buildout: 1. 212 Single-Family Detached Dwelling Units 2. 196 Multi-Family Housing (Low-Rise) Dwelling Units The methodology was prepared in accordance with the Standardized Transportation Impact Studies (TIS) Methodology and procedures (STIP) (Updated August 2023). We are submitting the information to the St. Lucie County Public Works department for review and upon approval will continue with the traffic analysis. Figure 1 illustrates the proposed development location. APPENDIX A Page 258 of 456 The Club at Indrio Creek, 311001 Traffic Analysis / Methodology Page 2 of 11 Figure 1: Proposed Site Location TRIP GENERATION Trip Generation The study uses trip generation rates for Single Family Detached (ITE Land Use 210) and Multi-Family Housing (Low-Rise) (ITE Land Use 220) published in the Institute of Transportation Engineering’s (ITE) manual, Trip Generation Manual (12th Edition). The proposed development will generate the following net new external and driveway trips: • 3,346 daily, 232 AM peak hour (57 in/175 out), and 306 PM peak hour (193 in/113 out) trips. Internal Capture Rate Internal capture is 0. Pass-by Rate Factor The pass-by capture is 0. Indrio Road Se m i n o l e R o a d Em e r s o n A v e nu e Project Site Ki n g s H i g h w a y SR 6 0 7 Page 259 of 456 The Club at Indrio Creek, 311001 Traffic Analysis / Methodology Page 3 of 11 INVENTORY & PLANNING DATA Availability / Use of County & State Data MEP will obtain count data, use FDOT’s Florida Traffic Online traffic counts and supplement from the St. Lucie County TPO Traffic Counts and Level of Service Report (2025) for current traffic counts. Procedures for Intersection Analysis MEP will utilize the software identified in the STIP. STUDY AREA Traffic Distribution / Assignment Technique and approach Traffic distribution and assignment was developed based upon a select zone assignment for the project using the Tresure Coast Regional Planning Model (TCRPM) 5.1 (see Appendix). The overall assignment is shown in Exhibit 3. Radius of Impact (ROI) Based on the STIP, Appendix B, the area of influence for transportation concurrency is 2.0 miles. St. Lucie County LDC evaluates concurrency based on the new external daily trips on the surrounding rounds. Therefore, PM peak hour analyses will be performed. Figure 2 illustrates the two-mile radius. In addition, the study will analyze impacted roadways, which are any Major Road Segment on which the peak-hour project traffic consumes 5 (five) percent or more of the existing or committed peak-hour peak direction service capacity (consistent with the STIP). Page 260 of 456 The Club at Indrio Creek, 311001 Traffic Analysis / Methodology Page 4 of 11 Figure 2. Two (2) Miles Radius Map Study Intersections The project will study the following intersections: 1. Indrio Road & Koblegard Road 2. Indrio Road & Johnston Road 3. Indrio Road & Emerson Avenue 4. Indrio Road & Seminole Road 5. Indrio Road & Kings Highway Intersections will be analyzed using the HCM methodology. Right-turns on red, as estimated by Synchro 12, will be utilized in the study. ROADWAY ANALYSIS Roadway Analysis MEP will utilize AM & PM peak hour traffic data for each roadway segment within the study area. The traffic data for each segment will be compared with the service volumes for each respective segment to determine if adequate capacity is available on each roadway segment. Historical Growth Rate 2-Mile Radius Indrio Rd Em e r s o n A v e Jo h n s t o n R d Ki n g s H w y Se m i n o l e R d Page 261 of 456 The Club at Indrio Creek, 311001 Traffic Analysis / Methodology Page 5 of 11 Historic growth rates were developed based on available FDOT Traffic Online data. The historic annual growth on the surrounding facilities between 2020 and 2024 is 3.8%. Data showing the growth calculations are contained in Exhibit 4. Service Volume MEP will utilize the TPO service volumes on all non-state study roadways. State, improved or unclassified roads will utilize Service Volumes from FDOT’s 2023 Multimodal Quality/Level of Service Handbook. Background Traffic Background traffic identifies how the study area’s transportation system is forecast to operate in the buildout year. This includes traffic growth that is associated with the general (historic) growth in the area and the growth due to the development of unbuilt portions of approved major developments. The existing peak hour traffic volumes will be increased based on the greater of the annual compound growth rate or a 1% growth rate plus approved site plan traffic to develop the projected year 2031 background traffic volumes. The following approved or nearly approved projects and their traffic were included in the analysis: The committed project traffic will be calculated by as follows: • 25% Preliminary Projects + 100% Buc-ee’s + 100% Approved Projects • Bedner Farms (Preliminary for Commercial) • Indrio & I-95 Development (25%) (Zoning Approval Only) (Preliminary) • Buc-ee’s • Publix at Indrio • Indrio Woods • Sabal Palm Grove • Cabo Rio RV • Indrio Groves (25%) (Not Approved) • Eagle Bend (Preliminary) • 2098 Johnston Road (Preliminary) • NVR Fort Pierce (Serenoa) • Pineapple Grove • 4540 North Kings Highway (Preliminary) • Indrio Townhomes (Preliminary) • Sea Grove Segment Analysis Should an arterial analysis become necessary, an arterial analysis will be performed using the most current version of Synchro V12. The green times, cycle lengths, and volumes will be provided by St. Lucie County Traffic Timing Data or field-obtained signal timing results. DRIVEWAY ANALYSIS Page 262 of 456 The Club at Indrio Creek, 311001 Traffic Analysis / Methodology Page 6 of 11 Site Access The proposed conceptual site plan has been provided by the owner and is located in the Appendix. The project proposes the following driveways: • Driveway 1 (Emerson Avenue) – Full Opening • Driveway 2 (Seminole Road) – Emergency Only All full openings will be analyzed during AM & PM peak hours. All driveways connected to State or County facilities will be evaluated for turn-lanes. COMMITTED IMPROVEMENTS Based on review of FDOT’s 5-Year Work Program and the St. Lucie TPO’s Transportation Improvement Program, which includes St. Lucie County’s 5-Year Capital Improvement Plan. The following improvement is identified in the plans to add capacity within the study area: • Kings Highway (SR 713) – St. Lucie Boulevard to Indrio Road – 4-Laning – ROW 2027 • SR-68/Orange Avenue from SR-713/Kings Highway to E of SR-9/I-95 SB Ramp – Interchange Improvements – 2029 • Oslo Road - 82nd Ave to 58th Ave – 4-Laning – Under Construction • Oslo Road & I-95 Interchange – Under Construction • Buc-ees Committed Improvements: 1. Construct a 2nd northbound right-turn lane and urbanize the northbound right-turn off ramp at the intersection of I-95 northbound Ramp. Urbanizing the turn lane includes signalizing the movement, reducing the turning radius, and removing the free flow condition. 2. Coordinate the I-95 northbound and southbound ramp signals with the intersection of Indrio Road & Koblegard Road. 3. Construct approximately 1,250 feet of Koblegard Road as a 4-lane facility south of Indrio Road and construct the northbound approach at the intersection of Indrio Road & Koblegard Road with the following: a. Two northbound left turn lanes b. One northbound through lane c. One northbound right turn lane 4. Make additional improvements at the intersection of Indrio & Koblegard Road, including a. Construct one eastbound right turn lane b. Extend the westbound left turn lane 5. Construct an ingress-only driveway approximately 440 feet west of the intersection of Indrio Road & Koblegard Road, outside of FDOT limited access right-of-way (ROW). APPENDIX 1. Trip Generation 2. Driveway Distribution 3. Assignment Map Page 263 of 456 The Club at Indrio Creek, 311001 Traffic Analysis / Methodology Page 7 of 11 4. Growth Rate Calculation 5. FDOT’s Traffic Data a. Annual Average Daily Traffic Report (2024) 6. Conceptual Site Plan 7. Treasure Coast Regional Planning Model (TCRPM) Page 264 of 456 The Club at Indrio Creek, 311001 Traffic Analysis / Methodology Page 8 of 11 Exhibit 1: Trip Generation Land Use Daily AM Peak Hour PM Peak Hour Trips Total In Out Total In Out Proposed Traffic 212 DU 1,976 148 40 108 192 119 73 Multi-family Housing (Low-rise)196 DU 1,224 82 20 62 101 63 38 3,200 230 60 170 293 182 111 3,200 230 60 170 293 182 111 Note: Trip generation was calculated using the following data: Pass-by PM Peak Hour Land Use ITE Code Unit Daily Rate Rate in/out in/out Equation 210 DU 0% 27/73 62/38 220 DU 0% 24/76 62/38 ITE 12th Edition Copyright © 2025, MacKenzie Engineering and Planning, Inc. Single Family Detached NET CHANGE IN TRIPS (FOR THE PURPOSES OF CONCURRENCY) NET CHANGE IN DRIVEWAY VOLUMES AM Peak Hour Intensity Rate Single Family Detached T = 8.07(X) + 265.45 T = 0.67(X) + 5.59 Ln(T) = 0.92 Ln(X) + 0.33 Multi-family Housing (Low-rise)T = 5.63(X) + 120.45 T = 0.35(X) + 12.93 T = 0.48(X) + 7.35 Page 265 of 456 The Club at Indrio Creek, 311001 Traffic Analysis / Methodology Page 9 of 11 Exhibit 2: Driveway Trips (in) 14% (25) 8 34 (102) 56%(in)56%(in) Indrio Road (in)30% (55) 18 (out)56% 51 24 95 (33) (16) (62) 30% 14% 56% (out) (out) (out)In Out In Out 60 170 182 111 100% (182) 60 170 (111) 100% 0 0 0% 0 00% 3,200293 230 Em e r s o n A v e n u e Se m i n o l e R o a d PROJECT DRIVEWAY TRIPS Daily AM Peak Hour PM Peak Hour Total Total DW 1 DW 2 (Emergency Only) 3,200 230 293 THE CLUB AT INDRIO CREEK PROPOSED PROJECT DRIVEWAY TRAFFIC Total Daily Driveway TripsPM Peak Hour Trips AM Peak Hour Trips Project Site Page 266 of 456 The Club at Indrio Creek, 311001 Traffic Analysis / Methodology Page 10 of 11 Exhibit 3: Trip Assignment Jo h n s t o n R d Ki n g s H w y Se m i n o l e R d Indrio Rd Ko b l e g a r d R d 9% 5% 8% 15% 30% 7% 14 % 13% 11% Em e r s o n A v e Fo r t P i e r c e B l v d 6% 10 0 % 50% 8% 10% 56% 56% 1% 1% 3% 29 % 11 % Page 267 of 456 The Club at Indrio Creek, 311001 Traffic Analysis / Methodology Page 11 of 11 Exhibit 4: Growth Rate Station Description 2020* 2021 2022 2023 2024 94-0038 Indrio Rd, E of I-95 12,400 14,400 15,100 13,100 280 2.1% 94-0281 Indrio Rd, W of Kings Hwy 11,000 13,900 14,700 14,200 1040 7.3% 94-7012 Indrio Rd, E of Kings Hwy 7,400 94-7029 Johnston Rd, N of Indrio Rd 94-0085 Johnston Rd, N of Meadowoods Dr 2,200 94-7004 Emerson Ave, N of Indrio Rd 5,600 6,700 367 5.5% 88-0175 Emerson Ave, S of CR 606/Olso Rd 9,400 94-0006 Kings Hwy, S of Indrio Rd 14,200 13,500 15,300 16,400 840 5.1% 94-0745 Kings Hwy, N of Indrio Rd 14,900 13,600 15,100 14,100 -90 -0.6% 3.8% 3.8% * 2020 Data were excluded due to COVID Average Daily Traffic Annual Absolute Growth Growth Rate Weighted Average Growth Rate Used Page 268 of 456 FLORIDA DEPARTMENT OF TRANSPORTATION TRANSPORTATION STATISTICS OFFICE 2024 HISTORICAL AADT REPORT COUNTY: 88 - INDIAN RIVER SITE: 0175 - SR 607 / EMERSON AVE - S OF CR 606/OLSO RD AT C/L YEAR AADT DIRECTION 1 DIRECTION 2 *K FACTOR D FACTOR T FACTOR ---- ---------- ------------ ------------ --------- -------- -------- 2024 9400 F N 4700 S 4700 9.00 51.10 7.20 2023 9400 C N 4700 S 4700 9.00 53.10 7.20 2022 10200 S N 5300 S 4900 9.00 52.80 5.90 2021 10200 F N 5300 S 4900 9.00 50.90 5.90 2020 10400 C N 5400 S 5000 9.00 51.30 5.90 2019 10600 S N 5400 S 5200 9.00 51.00 5.30 2018 10600 F N 5400 S 5200 9.00 52.30 5.30 2017 10600 C N 5400 S 5200 9.00 50.90 5.30 2016 9200 S N 4700 S 4500 9.00 51.80 9.50 2015 9000 F N 4600 S 4400 9.00 51.80 9.50 2014 9000 C N 4600 S 4400 9.00 51.70 9.50 2013 7400 C N 3600 S 3800 9.00 50.80 5.50 2012 9200 C N 4700 S 4500 9.00 55.20 7.70 2011 9000 C N 4500 S 4500 9.00 55.70 7.70 2010 9200 C N 4600 S 4600 10.00 54.79 7.70 2009 8700 F N 4400 S 4300 9.97 55.49 11.40 AADT FLAGS: C = COMPUTED; E = MANUAL ESTIMATE; F = FIRST YEAR ESTIMATE S = SECOND YEAR ESTIMATE; T = THIRD YEAR ESTIMATE; R = FOURTH YEAR ESTIMATE V = FIFTH YEAR ESTIMATE; 6 = SIXTH YEAR ESTIMATE; X = UNKNOWN *K FACTOR: STARTING WITH YEAR 2011 IS STANDARDK, PRIOR YEARS ARE K30 VALUES Page 269 of 456 FLORIDA DEPARTMENT OF TRANSPORTATION TRANSPORTATION STATISTICS OFFICE 2024 HISTORICAL AADT REPORT COUNTY: 94 - ST.LUCIE SITE: 0006 - SR 713/KINGS HWY - S OF SR 614/INDRIO RD (COUNTY 6) YEAR AADT DIRECTION 1 DIRECTION 2 *K FACTOR D FACTOR T FACTOR ---- ---------- ------------ ------------ --------- -------- -------- 2024 16400 C N 7900 S 8500 9.00 51.10 7.30 2023 15300 C N 7400 S 7900 9.00 51.60 7.30 2022 13500 C N 6500 S 7000 9.00 51.40 7.30 2021 14200 C N 7000 S 7200 9.00 50.90 21.90 2020 13200 C N 6400 S 6800 9.00 51.30 6.20 2019 14900 F N 7300 S 7600 9.00 51.00 9.70 2018 15000 C N 7300 S 7700 9.00 51.30 7.60 2017 15300 C N 7300 S 8000 9.00 50.90 7.60 2016 14700 C N 7000 S 7700 9.00 50.90 7.60 2015 13000 C N 6100 S 6900 9.00 51.00 19.20 2014 13200 C N 6100 S 7100 9.00 50.80 7.30 2013 11800 C N 5800 S 6000 9.00 50.80 7.30 2012 13700 C N 6500 S 7200 9.00 56.80 7.30 2011 13600 C N 6500 S 7100 9.00 57.20 9.60 2010 14100 C N 6800 S 7300 10.32 55.40 9.60 2009 14700 C N 7100 S 7600 10.27 57.35 9.60 AADT FLAGS: C = COMPUTED; E = MANUAL ESTIMATE; F = FIRST YEAR ESTIMATE S = SECOND YEAR ESTIMATE; T = THIRD YEAR ESTIMATE; R = FOURTH YEAR ESTIMATE V = FIFTH YEAR ESTIMATE; 6 = SIXTH YEAR ESTIMATE; X = UNKNOWN *K FACTOR: STARTING WITH YEAR 2011 IS STANDARDK, PRIOR YEARS ARE K30 VALUES Page 270 of 456 FLORIDA DEPARTMENT OF TRANSPORTATION TRANSPORTATION STATISTICS OFFICE 2024 HISTORICAL AADT REPORT COUNTY: 94 - ST.LUCIE SITE: 0038 - SR 614/INDRIO RD - E OF SR 9/I-95 (COUNTY 38) YEAR AADT DIRECTION 1 DIRECTION 2 *K FACTOR D FACTOR T FACTOR ---- ---------- ------------ ------------ --------- -------- -------- 2024 13100 C E 6800 W 6300 9.50 51.10 13.70 2023 15100 C E 7800 W 7300 9.50 51.60 13.70 2022 14400 C E 7900 W 6500 9.50 51.40 13.70 2021 12400 C E 6300 W 6100 9.50 50.90 32.00 2020 9800 F E 5200 W 4600 9.50 51.30 32.00 2019 10200 C E 5400 W 4800 9.50 51.00 32.00 2018 8100 C E 4300 W 3800 9.50 51.30 7.60 2017 11700 C E 6100 W 5600 9.50 50.90 7.60 2016 9600 C E 5200 W 4400 9.00 50.90 7.60 2015 9400 C E 5100 W 4300 9.00 51.00 17.30 2014 9300 C E 4800 W 4500 9.00 50.80 11.00 2013 8600 C E 4500 W 4100 9.00 50.80 18.70 2012 9600 C E 5000 W 4600 9.00 56.80 9.70 2011 8200 C E 4300 W 3900 9.00 57.20 9.70 2010 10700 C E 5500 W 5200 10.32 55.40 9.70 2009 8300 C E 4200 W 4100 10.27 57.35 13.10 AADT FLAGS: C = COMPUTED; E = MANUAL ESTIMATE; F = FIRST YEAR ESTIMATE S = SECOND YEAR ESTIMATE; T = THIRD YEAR ESTIMATE; R = FOURTH YEAR ESTIMATE V = FIFTH YEAR ESTIMATE; 6 = SIXTH YEAR ESTIMATE; X = UNKNOWN *K FACTOR: STARTING WITH YEAR 2011 IS STANDARDK, PRIOR YEARS ARE K30 VALUES Page 271 of 456 FLORIDA DEPARTMENT OF TRANSPORTATION TRANSPORTATION STATISTICS OFFICE 2024 HISTORICAL AADT REPORT COUNTY: 94 - ST.LUCIE SITE: 0085 - JOHNSTON RD- NORTH OFMEADOWOODS DR YEAR AADT DIRECTION 1 DIRECTION 2 *K FACTOR D FACTOR T FACTOR ---- ---------- ------------ ------------ --------- -------- -------- 2024 2200 C N 1000 S 1200 9.50 51.10 15.70 2023 2200 V N 1100 S 1100 9.50 51.60 20.70 2022 2200 R N 1100 S 1100 9.50 51.40 23.80 2021 2200 T N 1100 S 1100 9.50 50.90 27.90 2020 2200 S N 1100 S 1100 9.50 51.30 23.30 2019 2300 F N 1100 S 1200 9.50 51.00 21.30 2018 2300 C N 1100 S 1200 9.50 51.30 20.00 2017 1400 V 0 0 9.50 50.90 20.00 2016 1400 R 0 0 9.50 50.90 19.60 2015 1400 T 0 0 9.50 51.00 41.80 2014 1400 S 9.50 50.80 49.50 2013 1400 F 0 0 9.00 50.80 11.90 2012 1400 C N 0 S 0 9.00 56.80 7.10 AADT FLAGS: C = COMPUTED; E = MANUAL ESTIMATE; F = FIRST YEAR ESTIMATE S = SECOND YEAR ESTIMATE; T = THIRD YEAR ESTIMATE; R = FOURTH YEAR ESTIMATE V = FIFTH YEAR ESTIMATE; 6 = SIXTH YEAR ESTIMATE; X = UNKNOWN *K FACTOR: STARTING WITH YEAR 2011 IS STANDARDK, PRIOR YEARS ARE K30 VALUES Page 272 of 456 FLORIDA DEPARTMENT OF TRANSPORTATION TRANSPORTATION STATISTICS OFFICE 2024 HISTORICAL AADT REPORT COUNTY: 94 - ST.LUCIE SITE: 0281 - SR 614 / INDRIO RD - W OF SR 713/KINGS HWY (COUNTY 281) YEAR AADT DIRECTION 1 DIRECTION 2 *K FACTOR D FACTOR T FACTOR ---- ---------- ------------ ------------ --------- -------- -------- 2024 14200 C E 7000 W 7200 9.00 51.10 10.80 2023 14700 C E 7300 W 7400 9.00 51.60 8.70 2022 13900 C E 6800 W 7100 9.00 51.40 10.10 2021 11000 C E 5000 W 6000 9.00 50.90 13.00 2020 8600 C E 4400 W 4200 9.00 51.30 11.30 2019 11200 F E 5500 W 5700 9.00 51.00 12.70 2018 11200 C E 5500 W 5700 9.00 51.30 12.70 2017 10500 C E 5600 W 4900 9.00 50.90 12.70 2016 11300 C E 5800 W 5500 9.00 50.90 7.90 2015 10100 C E 5200 W 4900 9.00 51.00 7.90 2014 10900 C E 5400 W 5500 9.00 50.80 7.90 2013 9800 C E 4900 W 4900 9.00 50.80 4.50 2012 8600 C E 4400 W 4200 9.00 56.80 4.50 2011 8800 C E 4500 W 4300 9.00 57.20 6.40 2010 10600 C E 5700 W 4900 10.32 55.40 10.30 2009 11100 C E 5600 W 5500 10.27 57.35 10.30 AADT FLAGS: C = COMPUTED; E = MANUAL ESTIMATE; F = FIRST YEAR ESTIMATE S = SECOND YEAR ESTIMATE; T = THIRD YEAR ESTIMATE; R = FOURTH YEAR ESTIMATE V = FIFTH YEAR ESTIMATE; 6 = SIXTH YEAR ESTIMATE; X = UNKNOWN *K FACTOR: STARTING WITH YEAR 2011 IS STANDARDK, PRIOR YEARS ARE K30 VALUES Page 273 of 456 FLORIDA DEPARTMENT OF TRANSPORTATION TRANSPORTATION STATISTICS OFFICE 2024 HISTORICAL AADT REPORT COUNTY: 94 - ST.LUCIE SITE: 0745 - SR 713/KINGS HWY - N OF SR 614/INDRIO RD (COUNTY 745) YEAR AADT DIRECTION 1 DIRECTION 2 *K FACTOR D FACTOR T FACTOR ---- ---------- ------------ ------------ --------- -------- -------- 2024 14100 C N 7500 S 6600 9.00 51.10 7.20 2023 15100 C N 7600 S 7500 9.00 51.60 20.50 2022 13600 C N 7000 S 6600 9.00 51.40 20.50 2021 14900 C N 7600 S 7300 9.00 50.90 20.50 2020 12400 C N 6500 S 5900 9.00 51.30 8.90 2019 13200 F N 6900 S 6300 9.00 51.00 8.90 2018 13200 C N 6900 S 6300 9.00 51.30 8.90 2017 14500 C N 7400 S 7100 9.00 50.90 11.60 2016 13900 C N 6700 S 7200 9.00 50.90 11.60 2015 12900 C N 6200 S 6700 9.00 51.00 11.60 2014 12100 C N 6400 S 5700 9.00 50.80 8.00 2013 11800 C N 6100 S 5700 9.00 50.80 22.50 2012 12300 C N 6300 S 6000 9.00 56.80 8.80 2011 14400 C N 7600 S 6800 9.00 57.20 8.80 2010 12900 C N 6700 S 6200 10.32 55.40 8.80 2009 13700 C N 6900 S 6800 10.27 57.35 11.20 AADT FLAGS: C = COMPUTED; E = MANUAL ESTIMATE; F = FIRST YEAR ESTIMATE S = SECOND YEAR ESTIMATE; T = THIRD YEAR ESTIMATE; R = FOURTH YEAR ESTIMATE V = FIFTH YEAR ESTIMATE; 6 = SIXTH YEAR ESTIMATE; X = UNKNOWN *K FACTOR: STARTING WITH YEAR 2011 IS STANDARDK, PRIOR YEARS ARE K30 VALUES Page 274 of 456 FLORIDA DEPARTMENT OF TRANSPORTATION TRANSPORTATION STATISTICS OFFICE 2024 HISTORICAL AADT REPORT COUNTY: 94 - ST.LUCIE SITE: 7004 - EMERSON AVE - N OF INDRIO RD (COUNTY 105) YEAR AADT DIRECTION 1 DIRECTION 2 *K FACTOR D FACTOR T FACTOR ---- ---------- ------------ ------------ --------- -------- -------- 2024 6700 C N 3100 S 3600 9.00 51.10 14.10 2023 5800 S N 2900 S 2900 9.00 51.60 17.80 2022 5600 F N 2800 S 2800 9.00 51.40 17.80 2021 5600 C N 2800 S 2800 9.00 50.90 17.80 2020 5100 S N 2600 S 2500 9.00 51.30 7.10 2019 5300 F N 2700 S 2600 9.00 51.00 7.10 2018 5300 C N 2700 S 2600 9.00 51.30 7.10 2017 5200 S N 2700 S 2500 9.00 50.90 8.40 2016 5200 F N 2700 S 2500 9.00 50.90 8.40 2015 5200 C N 2700 S 2500 9.00 51.00 8.40 2014 4300 S N 2200 S 2100 9.00 50.80 9.40 2013 4300 F N 2200 S 2100 9.00 50.80 18.70 2012 4300 C N 2200 S 2100 9.00 56.80 4.50 2011 4600 S N 2300 S 2300 9.00 57.20 7.90 2010 4600 F N 2300 S 2300 10.32 55.40 7.90 2009 4600 C N 2300 S 2300 10.27 57.35 7.90 AADT FLAGS: C = COMPUTED; E = MANUAL ESTIMATE; F = FIRST YEAR ESTIMATE S = SECOND YEAR ESTIMATE; T = THIRD YEAR ESTIMATE; R = FOURTH YEAR ESTIMATE V = FIFTH YEAR ESTIMATE; 6 = SIXTH YEAR ESTIMATE; X = UNKNOWN *K FACTOR: STARTING WITH YEAR 2011 IS STANDARDK, PRIOR YEARS ARE K30 VALUES Page 275 of 456 FLORIDA DEPARTMENT OF TRANSPORTATION TRANSPORTATION STATISTICS OFFICE 2024 HISTORICAL AADT REPORT COUNTY: 94 - ST.LUCIE SITE: 7012 - INDRIO RD - E. OF KINGS HWY (COUNTY 114) YEAR AADT DIRECTION 1 DIRECTION 2 *K FACTOR D FACTOR T FACTOR ---- ---------- ------------ ------------ --------- -------- -------- 2024 7600 S E 3500 W 4100 9.00 51.10 8.20 2023 7600 F E 3500 W 4100 9.00 51.60 7.10 2022 7400 C E 3400 W 4000 9.00 51.40 5.00 2021 5200 V E 2500 W 2700 9.00 50.90 7.20 2020 5200 R E 2500 W 2700 9.00 51.30 31.50 2019 5400 T E 2600 W 2800 9.00 51.00 7.80 2018 5400 S E 2600 W 2800 9.00 51.30 7.60 2017 5400 F E 2600 W 2800 9.00 50.90 7.60 2016 5400 C E 2600 W 2800 9.00 50.90 7.60 2015 5100 S E 2500 W 2600 9.00 51.00 41.80 2014 5100 F E 2500 W 2600 9.00 50.80 49.50 2013 5100 C E 2500 W 2600 9.00 50.80 11.90 2012 5000 F E 2500 W 2500 9.00 56.80 7.10 2011 5000 C E 2500 W 2500 9.00 57.20 7.60 2010 5500 S E 2700 W 2800 10.32 55.40 7.70 2009 5500 F E 2700 W 2800 10.27 57.35 7.70 AADT FLAGS: C = COMPUTED; E = MANUAL ESTIMATE; F = FIRST YEAR ESTIMATE S = SECOND YEAR ESTIMATE; T = THIRD YEAR ESTIMATE; R = FOURTH YEAR ESTIMATE V = FIFTH YEAR ESTIMATE; 6 = SIXTH YEAR ESTIMATE; X = UNKNOWN *K FACTOR: STARTING WITH YEAR 2011 IS STANDARDK, PRIOR YEARS ARE K30 VALUES Page 276 of 456 FLORIDA DEPARTMENT OF TRANSPORTATION TRANSPORTATION STATISTICS OFFICE 2024 HISTORICAL AADT REPORT COUNTY: 94 - ST.LUCIE SITE: 7029 - JOHNSTON RD - N OF INDRIO RD (COUNTY 135) YEAR AADT DIRECTION 1 DIRECTION 2 *K FACTOR D FACTOR T FACTOR ---- ---------- ------------ ------------ --------- -------- -------- 2024 6900 V N 3500 S 3400 9.50 51.10 15.70 2023 6900 R N 3500 S 3400 9.50 51.60 20.70 2022 6700 T N 3400 S 3300 9.50 51.40 23.80 2021 6700 S N 3400 S 3300 9.50 50.90 27.90 2020 6700 F N 3400 S 3300 9.50 51.30 23.30 2019 7000 C N 3600 S 3400 9.50 51.00 21.30 2018 7000 V N 3600 S 3400 9.50 51.30 20.00 2017 7000 R N 3600 S 3400 9.50 50.90 20.00 2016 6800 T N 3500 S 3300 9.50 50.90 19.60 2015 6800 S N 3500 S 3300 9.50 51.00 41.80 2014 6800 F N 3500 S 3300 9.50 50.80 49.50 2013 6800 C N 3500 S 3300 9.00 50.80 11.90 2012 6000 C N 3100 S 2900 9.00 56.80 7.10 2011 6000 C N 3100 S 2900 9.00 57.20 8.70 2010 6200 F N 3100 S 3100 10.32 55.40 8.70 2009 6200 C N 3100 S 3100 10.27 57.35 8.70 AADT FLAGS: C = COMPUTED; E = MANUAL ESTIMATE; F = FIRST YEAR ESTIMATE S = SECOND YEAR ESTIMATE; T = THIRD YEAR ESTIMATE; R = FOURTH YEAR ESTIMATE V = FIFTH YEAR ESTIMATE; 6 = SIXTH YEAR ESTIMATE; X = UNKNOWN *K FACTOR: STARTING WITH YEAR 2011 IS STANDARDK, PRIOR YEARS ARE K30 VALUES Page 277 of 456 COUNTRYSIDE: (2 DU/ACRE)869,455 S.F. COUNTRYSIDE: (1 DU/ACRE)196,693 S.F. INTERIOR COUNTRYSIDE:524,534 S.F. FLOW WAY: (2 DU/ACRE)265,731 S.F. FLOW WAY: (1 DU/ACRE)419,197 S.F. LITTORAL: (2 DU/ACRE)67,540 S.F. LITTORAL: (1 DU/ACRE)76,188 S.F. INTERIOR LAKES/SWALES:218,376 S.F. EMERSON ROW DEDICATION: 160,738 S.F. SPINE ROW DEDICATION: 226,199 S.F. LME: (2 DU/ACRE)118,767 S.F. LME: (1 DU/ACRE)73,906 S.F. P-TO B P-TOB P - T O B P - T O B P - T O B P - T O B P - T O B P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P-TOB P - T O B P - T O B P - T O B SE M I N O L E R O A D EM E R S O N A V E FP F W C D FP F W C D FP F W C D PR O P O S E D E M E R S O N 8 0 ' R . O . W . DE D I C A T I O N SITE BENCHMARK #1SET IRON RODELEVATIONS 19.20' SITE BENCHMARK #2SET IRON RODELEVATIONS 20.43' COUNTRYSIDE COUNTRYSIDE N0 ° 3 5 ' 0 6 . 7 4 " E 20 0 9 . 0 2 7 N0 ° 3 5 ' 0 6 . 7 4 " E 18 0 8 . 2 0 1 S89° 54' 38.11"E1292.839 N0 ° 3 7 ' 2 9 . 7 8 " E 17 0 . 0 0 7 S89° 54' 38.11"E1052.235 S0 ° 3 9 ' 5 3 . 2 6 " W 20 8 . 7 2 1 S89° 54' 38.11"E208.721 S0 ° 3 9 ' 5 3 . 2 6 " W 17 6 3 . 5 8 9 S89° 57' 23.02"W589.804 S0 ° 3 8 ' 4 1 . 4 6 " W 23 0 . 0 1 7 N89° 57' 23.02"E581.413 S0 ° 1 4 ' 4 3 . 3 1 " W 27 3 . 1 7 3 S89° 58' 37.21"W1251.214 N0 ° 2 5 ' 3 8 . 5 8 " E 30 1 . 7 3 0 S89° 57' 23.02"W1292.257 N0 ° 3 6 ' 3 5 . 0 8 " E 20 1 . 0 1 3 S89° 24' 53.26"E52.381 L=1450.187,R=1608.000 D=51.6726 L=1379.595,R=1528.000 D=51.7310 N89° 57' 23.02"E58.448 S89° 24' 53.26"E53.096 L=1378.432,R=1528.000 D=51.6874 L=1451.825,R=1608.000 D=51.7310 N89° 57' 23.02"E60.006 PROPOSEDLIFT STATION P - T O B P - T O B P- T O B P - T O B P - T O E P - T O E P- T O E P - T O E PROPOSED LAKE66,582 S.F. PROPOSEDCIVIC PARK AREA 57,473 S.F. P-TO E P-TOE P-TOE PROPOSED LAKE 44,709 S.F. PROPOSEDLAKE 88,878 S.F. PROPOSED FLOW WAY 419,197 S.F. PROPOSED FLOW WAY 265,731 S.F. PROPOSED CLUB HOUSE AREA PROPOSED CIVIC PARK AREA 62,823 S.F. 90.0' 40.0' 90.0' 25.0'50.0' 2 DU/ACRE LINE 1 DU/ACRE LINE 20.0 ' WIDE R O A D 80.0 ' R.O. W . 40.0 ' A L L E Y 205.0' 1 2 0 . 0 ' ( T Y P ) 17 1 . 9 ' 200.3' 38 8 . 5 ' 256.7' P-TOB P-TOB P - T O B P-TOB P-T O B P - T O B P-TOB P-TO B P-T O E P - T O E P-TOE P-TO E P-TO B P-TOB P-TOB PROPOSEDLIFT STATION PEDESTRIAN PATH 1622 LF PEDESTRIAN PATH 1635 LF PEDESTRIAN PATH 2037 LF PEDESTRIAN PATH 2437 LF P E D E S T R I A N P A T H 2 12 7 L F P E D E S T R I A N P A T H 15 9 5 L F P ED ESTRIAN PATH 2356LF PEDESTRIAN PATH1875LFPEDESTRIAN PATH 1575 LFPEDESTRIAN PATH 1523 LF PE D E S T R I A N P A T H 1 3 7 3 L F PE D E S T R I A N P A T H 1 5 9 3 L F PEDESTRIANPATH 1748LF PEDESTRIANPATH 2207 LF icrosoft Corporation © 2025 Maxar ©CNES (2025) Distribution Airbus DS © 2025 TMAP MOBILITY Earthstar Geographics SIO VICINITY MAP SCALE: 1:1,000 EXISTING METER PROPOSED MITEREDEND SECTION PROPOSEDSIGN HANDICAP PARKING SYMBOL EXISTING CONCRETE EXISTING PAVEMENT EXISTING UTILITY POLE EXIST. DRAINAGE INLET EXISTING STREET LIGHT PROPOSED LIGHT POLE (SINGLE) DRAINAGE FLOW ARROW PROPOSED LIGHT POLE (DOUBLE) PARKING STALL COUNT PROPOSED CONCRETE PROPOSED DRAINAGE INLET EXISTING DRAINAGE PROPOSED DRAINAGE PIPE VERTICAL DATUM NOTE: ELEVATIONS SHOWN HEREON ARE RELATIVE TO THE NORTH AMERICAN VERTICAL DATUM OF 1988(N.A.V.D.88) AND ARE GIVEN IN U.S. SURVEY FEET UNLESS OTHERWISE NOTED. *GENERAL ACCEPTED CONVERSION: NAVD + 1.475 = NGVD NOTE: THE PROPERTY OWNER, CONTRACTOR, AND AUTHORIZED REPRESENTATIVES SHALL PROVIDEPICKUP, REMOVAL, AND DISPOSAL OF LITTER WITHIN THE PROJECT LIMITS AND SHALL BE RESPONSIBLE FOR MAINTENANCE OF THE AREA FROM THE EDGE OF PAVEMENT TO THEPROPERTY LINE WITHIN THE RIGHT-OF-WAY PROPOSED PAVEMENT SITE # ( IN FEET ) GRAPHIC SCALE 0150 75 150 300 450 1 inch = 150 ft. 10250 Village Parkway, Suite 201 Port Saint Lucie, Florida 34987 772.462.2455930 S. Harbor City Blvd, Suite 506Melbourne, FL 32901321.280.9969 1234567 PROJECT TITLE DATE SCALE DRAWN BY DESIGNED BY CHECKED BY PROJECT No. DRAWING No.REV. A B C D A B C D FIL E L O C A T I O N : Z : \ E D C - 2 0 2 5 \ 2 5 - 1 1 3 - I N D R I O C R E E K - S E M I N O L E R O A D - 1 2 7 - A C R E S \ E N G I N E E R I N G \ A U T O C A D \ D W G S \ 2 5 - 1 1 3 R 1 5 . D W G , 2 0 2 5 . 0 7 . 2 4 , 3 : 2 6 P M CERTIFICATE OF AUTHORIZATION No. 1234567 HALEY WARDENGINEERING ENVIRONMENTAL SURVEYING WWW.HALEYWARD.COM LAND PLANNING INTERIOR DESIGN PRELIMINARY DEVELOPMENT PLAN 7/22/2025 AS SHOWN JJL JJL MDL 25-113 R15.DWG PDP C.O.A. No. DESCRIPTION BY CHK.DATE DRAWING ISSUE STATUS REV. Know what's below. Call before you dig. www.callsunshine.com It's fast. It's free. It's the law. 10250 SW VILLAGE PARKWAY - SUITE 201PORT SAINT LUCIE, FL 34987  772-462-2455 (DATE)MARK LANDSMAN, P.E.#96288 THE CLUB AT INDRIO CREEK ST. LUCIE COUNTY, FLORIDA DESCRIPTION WETLANDS RARE HABITATTHREATENED SPECIESENDANGERED SPECIES SPECIES OF SPECIAL CONCERNINVASIVE/EXOTIC VEGETATION FOUND(YES/NO)AGENCY CONTACTINFORMATION MANAGEMENTPLAN(YES/NO) RELOCATIONPLAN(YES/NO) -- NOTE: PLEASE REFER TO THE ENVIRONMENTAL ASSESSMENT COMPLETED BY XX ON DATED. ENVIRONMENTAL SITE ASSESSMENT STATEMENT -- ------ -- VICINITY MAP SCALE: 1:1,000 SITE DATALEGAL DESCRIPTION 1314-323-0002-000-314 34 39 S 1/2 OF NW 1/4 OF SW 1/4-LESS N 170 FT AND LESS CANAL AND RD RS/W (15.42 AC)1314-313-0000-000-8 14 34 39 S 1/2 OF NE 1/4 OF SW 1/4-LESS N 208.71 FT OF E 208.71 FT AND LESS RD AND CANALRS/W- (18.13 AC)1314-331-0001-000-1 14/23 34 39 FROM SW COR SEC 14 RUN N 89 DEG 30 MIN 19 SEC E ALG S LI OF SEC 48 FT TO ER/W LI EMERSON AV AND POB, TH N 00 DEG 07 MIN 22 SEC E ALG SD E R/W 1311.43 FT TO C/LOF DITCH, TH N 89 DEG 49 MIN 59 SEC E ALG C/L 1218.78 FT, TH S 45 DEG 07 MIN 23 SEC E46.22 FT, TH S 00 DEG 35 MIN 00 SEC W 1472.61 FT TO S LI OF N 6.18 AC OF NW 1/4 OF NW 1/4 OF SEC 23, TH S 89 DEG 30 MIN 19 SEC W 1239.97 FT TO E R/W EMERSON AV, TH N 00 DEG 10MIN 00 SEC E 200.88 FT TO POB (43.14 AC)1314-342-0001-000-5 14/23 34 39 W 1/2 OF SE 1/4 OF SW 1/4 AND N 230 FT OF NW 1/4 OF NE 1/4 OF NW 1/4 (24.72 AC)1323-211-0005-000-823 34 39 N 3/4 OF N 1/2 OF NE 1/4 OF NW 1/4-LESS N 230 FT AND LESS E 90 FT (7.93 AC) PARCEL ID #: 1314-323-0002-000-31314-313-0000-000-81314-331-0001-000-1 1314-342-0001-000-51323-211-0005-000-8 PROJECT NAME: THE CLUB AT INDRIO CREEK OWNERSHIP:BRINDHAVANAM LLC4528 SHILOH MILL BLVDJACKSONVILLE, FL 32246-1877 FUTURE LAND USE: TVC ZONING: AG-1 LAND SIZE:5,533,381 S.F. (127.03 AC) BUILDING DATA GROSS SQUARE FOOTAGE 408 UNITS PROPOSED SINGLE FAMILY 212 UNITS 40'S 109 UNITS 50'S 103UNITS PROPOSED TOWNHOMES 196 UNITS PROVIDER OF UTILITIES: WATER: FPUA WASTEWATER: FPUA IRRIGATION: N/A SOLID WASTE: ROLL OUT AND DUMPSTER AUTHORIZED STORMWATER DRAINAGE: THE SURFACE WATER MANAGEMENT SYSTEM FOR THE PROJECT WILL COLLECT SITERUNOFF IN A SERIES OF INLETS WHICH WILL CONVEY THE RUNOFF TO OFFSITE DRAINAGE AREA SOLID WASTE: BASED ON THE INTENDED USE OF THE BUILDING, THIS PROJECT WILL UTILIZE A DUMPSTERAREA FOR SOLID WASTE AND RECYCLABLE ITEMS. HAZARDOUS WASTE: ANY AND ALL HAZARDOUS OR TOXIC MATERIALS GENERATED OR USED OR STORED ON SITESHALL BE DISPOSED OF IN ACCORDANCE WITH ALL LOCAL, STATE AND FEDERALREGULATIONS. LANDSCAPE: REFER TO LANDSCAPE PLAN BY OTHERS. (NO PLANS AVAILABLE) ACCESSIBILITY AND ADA COMPLIANCE: ALL SIDEWALKS AND RAMPS WILL MEET FDOT AND ADA REQUIREMENTS. SITE F.I.R.M. PANEL: 12111C0070J ST. LUCIE COUNTY UNINCORPORATED AREA 120285 ZONE X SE M I N O L E R O A D EM E R S O N A V E RESTORED HABITAT R.O.W. DEDICATION ZONING CODE FOR: AG-1 (AGRICULTURAL - 1) YARD SETBACKS BUILDING BUILDING FRONT REAR SIDE CORNER COVERAGE HEIGHT PER CODE PROPOSED 50' 30' 20' 30'20(j)% MAX. 80(j)' MAX. 55'40 X X X%X' 164' 90' 5' 13' 18' 27'22'(TYP)7' 24' UNIT AREA: 1,980 S.F.(SINGLE)BUILDABLE AREA: 1,100 S.F. (55.56%)TOWNHOUSE LOT: 14,760 S.F.(0.34 AC) TYPICAL TOWNHOUSE LOT LAYOUT SCALE: 1"=40' LOT AREA: 3,600 S.F.BUILDABLE AREA: 2,250 S.F. (44.44%) 40' 50' R.O.W. 120' 25' FRONT BUILDING SETBACK 5' SIDEBUILDINGSETBACK 5' SIDEACCESSORYSETBACK 20' REARBUILDINGSETBACK 5' REARACCESSORY SETBACK 16' 10' U.E. 30' LOT AREA: 4,500 S.F.BUILDABLE AREA: 3,000 S.F. (47.41%) TYPICAL 50' WIDE LOT LAYOUT SCALE: 1"=40' TYPICAL 40' WIDE LOT LAYOUT SCALE: 1"=40' 12' 15' P- B E R M P- B E R M P- B E R M P-BERM 50' 50' R.O.W. 120' 25' FRONT BUILDING SETBACK 5' SIDEBUILDINGSETBACK 5' SIDEACCESSORYSETBACK 20' REARBUILDINGSETBACK 5' REARACCESSORY SETBACK 10' U.E. 40' 12' 15' P- B E R M P- B E R M P-BERM P-BERM 75'75' COUNTRYSIDE Page 278 of 456 (Licensed to Mackenzie Engineering) 0 0 10 0 0 0 0 0 0 0 00 1 0 00 0 0 10 0 0 0 0 0 0 0 0 0 1 0 0 00 0 0 0 0 0 0 0 00 0 00 00 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 0 0 0 00 40 0 1 1 0 0 1 2 1 0 0 0 0 0 3 0 0 10 0 1 0 0 0 1 0 0 5 2 0 0 1 0 2 0 0 0 0 0 1 0 0 00 0 0 1 1 1 0 0 0 0 0 2 1 0 0 1 00 0 0 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 10 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 1 1 1 0 1 1 0 1 0 0 0 1 2 04 5 1 0 0 1 0 5 0 1 0 1 0 10 0 0 1 3 0 3 7 20 7 7 0 7 7 1 7 0 7 7 7 3 03 3 5 0000 20 0 1 1 0 20 0 0 0 0 1 11 31 11 11 10 10 11 9 10 10 8 10 0 7 7 7 7 7 7 0 0 1 0 0 1 69 1 0 1 1 64 6 1 1 22 18 4 23 18 11 18 18 23 23 38 13 1 38 38 38 38 13 1312 1 0 12 2 1 0 2 2 0 0 20 2 1 1112 13 13 01111 2 3 3 9 0 10 3 9 12 0 9 0 0 9 6 9 6 8 7 0 1 11 1 8 7 7 7 0 8 8 4 8 4 9 2 7 0 0 8 0 00 8 0 8 4 8 4 0 8 0 4 0 7 2 0 7 7 0 7 0 0 1 0 6 1 0 0 0 0 6 0 5 6 2 0 9 9 0 0 1 1 1 0 0 0 1 1 1 0 0 0 1 1 0 0 00 0 0 0 0 1 00 0 0 1 0 01 0 0 1 1 0 0 0 10 0 0 0 0 0 0 11 0 0 0 0 0 1 0 0 1 1 1 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 1 1 1 10 0 0 0 0 00 0 1 1 1 1 0 0 Page 279 of 456 Land Use: 210Single-Family Detached Housing Description A single-family detached housing site includes any single-family detached home on an individual lot. A typical site surveyed is a suburban subdivision. Specialized Land Use Data have been submitted for several single-family detached housing developments with homes that are commonly referred to as patio homes. A patio home is a detached housing unit that is located on a small lot with little (or no) front or back yard. In some subdivisions, communal maintenance of outside grounds is provided for the patio homes. The three patio home sites total 299 dwelling units with overall weighted average trip generation rates of 5.35 vehicle trips per dwelling unit for weekday, 0.26 for the AM adjacent street peak hour, and 0.47 for the PM adjacent street peak hour. These patio home rates, based on a small sample of sites, are lower than those for single-family detached housing (Land Use 210), lower than those for single-family attached housing (Land Use 215), and higher than those for senior adult housing—single- family (Land Use 251). (Source 1008) Additional Data The sites were surveyed in the 1990s, the 2000s, the 2010s, and the 2020s in Alabama, Arizona, British Columbia (CAN), California, Delaware, Illinois, Kentucky, Massachusetts, Minnesota, Montana, New Jersey, New York, North Carolina, Ontario (CAN), Oregon, Pennsylvania, South Carolina, South Dakota, Vermont, and West Virginia. Source Numbers 356, 357, 367, 384, 387, 407, 435, 522, 550, 552, 579, 598, 601, 603, 614, 637, 711, 716, 720, 728, 735, 868, 869, 903, 925, 936, 1005, 1007, 1008, 1010, 1033, 1066, 1077, 1078, 1079, 1204, 1221, 1225, 1236, 1251, 1265, 1267 230 Trip Generation Manual, 12th Edition • Volume 3 APPENDIX B Page 280 of 456 General Urban/Suburban and Rural (Land Uses 000–399)231 Single-Family Detached Housing(210) Vehicle Trip Ends vs:Dwelling Units On a: Weekday Setting/Location:General Urban/Suburban Number of Studies: 155 Avg. Num. of Dwelling Units: 261 Directional Distribution: 50% entering, 50% exiting Vehicle Trip Generation per Dwelling Unit Average Rate Range of Rates Standard Deviation 9.09 3.47 - 23.80 2.29 Data Plot and Equation 0 1000 2000 30000 10000 20000 30000 Average RateStudy Site Fitted Curve Fitted Curve Equation:T = 8.07(X) + 265.45 R²= 0.94 X = Number of Dwelling Units T = T r i p s E n d s Page 281 of 456 232 Trip Generation Manual, 12th Edition • Volume 3 Single-Family Detached Housing(210) Vehicle Trip Ends vs:Dwelling Units On a: Weekday, Peak Hour of Adjacent Street Traffic, One Hour Between 7 and 9 a.m. Setting/Location:General Urban/Suburban Number of Studies: 153 Avg. Num. of Dwelling Units: 239 Directional Distribution: 27% entering, 73% exiting Vehicle Trip Generation per Dwelling Unit Average Rate Range of Rates Standard Deviation 0.70 0.22 - 2.27 0.26 Data Plot and Equation 0 1000 2000 30000 1000 2000 Average RateStudy Site Fitted Curve Fitted Curve Equation:T = 0.67(X) + 5.59 R²= 0.89 X = Number of Dwelling Units T = T r i p s E n d s Page 282 of 456 General Urban/Suburban and Rural (Land Uses 000–399)233 Single-Family Detached Housing(210) Vehicle Trip Ends vs:Dwelling Units On a: Weekday, Peak Hour of Adjacent Street Traffic, One Hour Between 4 and 6 p.m. Setting/Location:General Urban/Suburban Number of Studies: 166 Avg. Num. of Dwelling Units: 266 Directional Distribution: 62% entering, 38% exiting Vehicle Trip Generation per Dwelling Unit Average Rate Range of Rates Standard Deviation 0.93 0.35 - 2.98 0.33 Data Plot and Equation 0 1000 2000 30000 1000 2000 3000 Average RateStudy Site Fitted Curve Fitted Curve Equation: Ln(T)= 0.92 Ln(X)+ 0.33 R²= 0.90 X = Number of Dwelling Units T = T r i p s E n d s Page 283 of 456 Land Use: 220Multifamily Housing (Low-Rise) Description Low-rise multifamily housing is a residential building with two or three floors (levels) of residences. Various configurations fit this description, including the following: • Walk-up apartment or multiplex—access to the individual dwelling units is typically internal to the structure and provided through a shared entry, stairway, and hallway. • Mansion apartment with several dwelling units within what appears from the outside to be a single- family dwelling unit. • Stacked townhouse designed to match the external appearance of a townhouse, but which has dwelling units that share both floors and walls and with access through a central entry and stairway. Land Use Subcategory Data are presented for two subcategories for this land use: (1) not close to rail transit and (2) close to rail transit. A site is considered close to rail transit if the walking distance between the residential site entrance and the closest rail transit station entrance is ½ mile or less. Additional Data For the three sites for which both the number of residents and the number of occupied dwelling units were available, there was an average of 2.72 residents per occupied dwelling unit. For the two sites for which the numbers of both total dwelling units and occupied dwelling units were available, an average of 96.2 percent of the total dwelling units were occupied. It is expected that the number of bedrooms and number of residents are likely correlated to the trips generated by a residential site. To assist in future analysis, trip generation studies of all multifamily housing should attempt to obtain information on occupancy rate and on the mix of residential unit sizes (i.e., number of units by number of bedrooms at the site complex). The sites were surveyed in the 1990s, the 2000s, the 2010s, and the 2020s in Arizona, British Columbia (CAN), California, Delaware, Florida, Illinois, Maine, Massachusetts, Minnesota, New Jersey, New York, Ontario (CAN), Oregon, Pennsylvania, South Carolina, South Dakota, Tennessee, Utah, and Washington. Source Numbers 357, 390, 412, 525, 530, 579, 583, 638, 864, 866, 896, 901, 903, 904, 936, 939, 944, 946, 947, 948, 963, 964, 966, 967, 1012, 1013, 1014, 1036, 1047, 1056, 1071, 1076, 1219, 1236, 1265, 1267 General Urban/Suburban and Rural (Land Uses 000–399)261 Page 284 of 456 262 Trip Generation Manual, 12th Edition • Volume 3 Multifamily Housing (Low-Rise)Not Close to Rail Transit (220) Vehicle Trip Ends vs:Dwelling Units On a: Weekday Setting/Location:General Urban/Suburban Number of Studies: 28 Avg. Num. of Dwelling Units: 208 Directional Distribution: 50% entering, 50% exiting Vehicle Trip Generation per Dwelling Unit Average Rate Range of Rates Standard Deviation 6.21 2.46 - 12.50 1.87 Data Plot and Equation 0 100 200 300 400 5000 1000 2000 3000 4000 Average RateStudy Site Fitted Curve Fitted Curve Equation:T = 5.63(X) + 120.45 R²= 0.70 X = Number of Dwelling Units T = T r i p s E n d s Page 285 of 456 General Urban/Suburban and Rural (Land Uses 000–399)263 Multifamily Housing (Low-Rise)Not Close to Rail Transit (220) Vehicle Trip Ends vs:Dwelling Units On a: Weekday, Peak Hour of Adjacent Street Traffic, One Hour Between 7 and 9 a.m. Setting/Location:General Urban/Suburban Number of Studies: 51 Avg. Num. of Dwelling Units: 219 Directional Distribution: 24% entering, 76% exiting Vehicle Trip Generation per Dwelling Unit Average Rate Range of Rates Standard Deviation 0.41 0.13 - 0.73 0.10 Data Plot and Equation 0 200 400 600 8000 100 200 300 Average RateStudy Site Fitted Curve Fitted Curve Equation:T = 0.35(X) + 12.93 R²= 0.81 X = Number of Dwelling Units T = T r i p s E n d s Page 286 of 456 264 Trip Generation Manual, 12th Edition • Volume 3 Multifamily Housing (Low-Rise)Not Close to Rail Transit (220) Vehicle Trip Ends vs:Dwelling Units On a: Weekday, Peak Hour of Adjacent Street Traffic, One Hour Between 4 and 6 p.m. Setting/Location:General Urban/Suburban Number of Studies: 61 Avg. Num. of Dwelling Units: 215 Directional Distribution: 62% entering, 38% exiting Vehicle Trip Generation per Dwelling Unit Average Rate Range of Rates Standard Deviation 0.52 0.08 - 1.04 0.13 Data Plot and Equation 0 200 400 600 8000 100 200 300 400 Average RateStudy Site Fitted Curve Fitted Curve Equation:T = 0.48(X) + 7.35 R²= 0.83 X = Number of Dwelling Units T = T r i p s E n d s Page 287 of 456 Roadway Name Location 2025 AADT * Volume LOS V/C PM Pk Hr Pk Dir Pk Hr Service Capacity AM Pk Hr Pk Dir V/C LOS Volume STATION ID Last Physical Count Year Traffic Counts and Level of Service Report 2025 7,201 US 1 to BUCHANAN DREASY ST 750 399 106 D 0.53 505 D 0.67 2021 7,201 BUCHANAN DR to YUCCA DREASY ST 540 399 106 D 0.74 505 D 0.94 2021 11,836 JENKINS RD to MCNEIL RDEDWARDS RD 630 627 174 D 1.00 607 D 0.96 2024 11,836 MCNEIL RD to SELVITZ RDEDWARDS RD 700 627 174 C 0.90 607 C 0.87 2024 15,105 SELVITZ RD to 25TH STEDWARDS RD 880 796 110 C 0.90 786 C 0.89 2024 16,580 25TH ST to SUNRISE BLVDEDWARDS RD 1,630 826 108 D 0.51 826 D 0.51 2024 13,835 SUNRISE BLVD to OLEANDER AVEEDWARDS RD 1,630 698 502 C 0.43 680 C 0.42 2024 7,600 OLEANDER AVE to US 1EDWARDS RD 1,630 394 173 C 0.24 356 C 0.22 2025 6,494 INDRIO RD to RUSSOS RDEMERSON AVE 1,070 480 105 C 0.45 474 C 0.44 2023 6,494 RUSSOS RD to FT PIERCE BLVDEMERSON AVE 760 480 105 C 0.63 474 C 0.62 2023 1,633 OLEANDER AVE to US 1FARMER'S MARKET RD 750 85 112 C 0.11 99 C 0.13 2023 15,500 OAKLYN ST to PORT ST LUCIE BLVDFLORESTA DR 920 1,043 317 F 1.13 917 D 1.00 2025 10,000 THORNHILL DR to CROSSTOWN PKWYFLORESTA DR 880 701 315 C 0.80 621 C 0.71 2025 10,000 PORT ST LUCIE BLVD to THORNHILL DRFLORESTA DR 880 701 315 C 0.80 621 C 0.71 2025 9,400 CROSSTOWN PKWY to PRIMA VISTA BLVDFLORESTA DR 920 515 109 C 0.56 552 C 0.60 2025 9,000 PRIMA VISTA BLVD to AIROSO BLVDFLORESTA DR 920 470 107 C 0.51 515 C 0.56 2025 4,929 SELVITZ RD to BAYSHORE BLVDFLORESTA DR 630 354 313 C 0.56 377 C 0.60 2021 4,929 AIROSO BLVD to SELVITZ RDFLORESTA DR 880 354 313 C 0.40 377 C 0.43 2021 64,338 BECKER RD to PORT ST LUCIE BLVDFLORIDA'S TURNPIKE 979913 2024 66,500 MARTIN C.L. to BECKER RDFLORIDA'S TURNPIKE 971958 2024 55,450 PORT ST LUCIE BLVD to OKEECHOBEE RDFLORIDA'S TURNPIKE 971964 2024 42,350 OKEECHOBEE RD to INDIAN RIVER C.L.FLORIDA'S TURNPIKE 971968 2024 3,375 INDRIO RD to EMERSON AVEFT PIERCE BLVD 540 229 226 C 0.42 235 C 0.44 2023 2,511 OLEANDER AVE to US 1GARDENIA AVE 750 194 666 C 0.26 184 C 0.25 2022 53,466 W OF I-95 to E OF I-95GATLIN BLVD 3,170 2,620 945075 C 0.83 2,620 C 0.83 2024 53,466 E OF I-95 to SAVAGE BLVDGATLIN BLVD 3,170 2,620 945075 C 0.83 2,620 C 0.83 2024 47,500 SAVAGE BLVD to ROSSER BLVDGATLIN BLVD 3,170 2,111 740 C 0.67 2,481 C 0.78 2025 40,500 ROSSER BLVD to SAVONA BLVDGATLIN BLVD 3,170 1,781 741 C 0.56 2,068 C 0.65 2025 34,500 SAVONA BLVD to PORT ST LUCIE BLVDGATLIN BLVD 3,170 1,472 742 C 0.46 1,498 C 0.47 2025 4,054 25TH ST to OKEECHOBEE RDGEORGIA AVE 600 236 667 C 0.39 226 C 0.38 2023 4,054 OKEECHOBEE RD to 17TH STGEORGIA AVE 750 236 667 C 0.31 226 C 0.30 2023 4,817 17TH ST to 13TH STGEORGIA AVE 600 245 508 C 0.41 247 C 0.41 2023 6 * Volumes shown were adjusted using FDOT Seasonal Factors * AADT = Annual Average Daily Traffic (volumes for both directions where applicable) * NOTE: If the Last Count Year is older than the year of the report, the AADT is projected from historical traffic count data. * NOTE: A six digit number in the "STATION ID" column identifies segment counted by FDOT. Peak hour data is not available for locations on State roads due to differences in data availability, LOS Methodologies, and service level thresholds. Please refer to FDOT sources for detailed data on FDOT traffic counts. APPENDIX C Page 288 of 456 Roadway Name Location 2025 AADT * Volume LOS V/C PM Pk Hr Pk Dir Pk Hr Service Capacity AM Pk Hr Pk Dir V/C LOS Volume STATION ID Last Physical Count Year Traffic Counts and Level of Service Report 2025 2,211 13TH ST to 7TH STGEORGIA AVE 600 134 506 C 0.22 150 C 0.25 2023 1,972 7TH ST to US 1GEORGIA AVE 600 109 504 C 0.18 117 C 0.20 2023 11,314 MARTIN C.L. to BECKER RDGILSON RD 710 963 111 F 1.36 1,019 F 1.44 2024 3,300 BECKER RD to NW LAKERIDGE DRGILSON RD 540 177 775 C 0.33 198 C 0.37 2025 2,743 RANGE LINE RD to RESERVE BLVDGLADES CUT-OFF RD 1,070 172 668 B 0.16 182 B 0.17 2022 5,565 RESERVE BLVD to COMMERCE CENTER DRGLADES CUT-OFF RD 1,070 438 119 C 0.41 509 C 0.48 2022 550 CARLTON RD to RANGE LINE RDGLADES CUT-OFF RD 390 32 773 B 0.08 32 B 0.08 2025 5,600 COMMERCE CENTER DR to MIDWAY RDGLADES CUT-OFF RD 920 458 731 C 0.50 453 C 0.49 2024 10,534 MIDWAY RD to JENKINS RDGLADES CUT-OFF RD 790 605 115 D 0.77 597 D 0.76 2024 6,441 JENKINS RD to SELVITZ RDGLADES CUT-OFF RD 830 384 113 C 0.46 356 C 0.43 2023 2,268 KINGS HWY to JENKINS RDGRAHAM RD 630 143 669 C 0.23 144 C 0.23 2022 5,910 MARTIN C.L. to CHARLESTON DRGREEN RIVER PKWY 1,070 349 319 B 0.33 363 B 0.34 2024 5,910 CHARLESTON DR to MELALEUCA BLVDGREEN RIVER PKWY 1,070 349 319 B 0.33 363 B 0.34 2024 5,910 MELALEUCA BLVD to WALTON RDGREEN RIVER PKWY 1,070 349 319 B 0.33 363 B 0.34 2024 7,200 OKEECHOBEE RD to PETERSON RDHARTMAN RD 750 452 670 D 0.60 392 D 0.52 2025 7,200 PETERSON RD to DELAWARE AVEHARTMAN RD 540 452 670 D 0.84 392 D 0.73 2025 7,200 DELAWARE AVE to ORANGE AVEHARTMAN RD 790 452 670 D 0.57 392 D 0.50 2025 636 OKEECHOBEE RD to ORANGE AVEHEADER CANAL RD 670 43 121 B 0.06 42 B 0.06 2024 7,050 US 1 to LENNARD RDHILLMOOR DR 790 391 671 D 0.49 370 C 0.47 2023 79,895 MARTIN C.L. to GATLIN BLVDI-95 890334 2024 94,995 GATLIN BLVD to ST LUCIE WEST BLVDI-95 941901 2024 77,652 ST LUCIE WEST BLVD to MIDWAY RDI-95 941904 2024 82,598 MIDWAY RD to OKEECHOBEE RDI-95 941902 2024 74,811 OKEECHOBEE RD to ORANGE AVEI-95 940260 2024 56,920 ORANGE AVE to INDRIO RDI-95 941905 2024 46,817 INDRIO RD to INDIAN RIVER C.L.I-95 882003 2024 6,200 CITRUS AVE to ORANGE AVEINDIAN RIVER DR 750 378 762 D 0.50 395 D 0.53 2025 6,200 ORANGE AVE to AVENUE AINDIAN RIVER DR 750 378 762 D 0.50 395 D 0.53 2025 6,900 AVENUE D to SEAWAY DRINDIAN RIVER DR 790 371 761 C 0.47 392 D 0.50 2025 6,900 AVENUE A to AVENUE DINDIAN RIVER DR 540 371 761 D 0.69 392 D 0.73 2025 6,600 PRIVATE RD to I-95 W RAMPINDRIO RD 1,080 421 771 C 0.39 406 B 0.38 2025 1,238 I-95 W RAMP to I-95 E RAMPINDRIO RD 940128 2024 7 * Volumes shown were adjusted using FDOT Seasonal Factors * AADT = Annual Average Daily Traffic (volumes for both directions where applicable) * NOTE: If the Last Count Year is older than the year of the report, the AADT is projected from historical traffic count data. * NOTE: A six digit number in the "STATION ID" column identifies segment counted by FDOT. Peak hour data is not available for locations on State roads due to differences in data availability, LOS Methodologies, and service level thresholds. Please refer to FDOT sources for detailed data on FDOT traffic counts. Page 289 of 456 Roadway Name Location 2025 AADT * Volume LOS V/C PM Pk Hr Pk Dir Pk Hr Service Capacity AM Pk Hr Pk Dir V/C LOS Volume STATION ID Last Physical Count Year Traffic Counts and Level of Service Report 2025 12,642 I-95 E RAMP to KOBLEGARD RDINDRIO RD 940038 2024 12,642 KOBLEGARD RD to JOHNSTON RDINDRIO RD 940038 2024 12,642 JOHNSTON RD to EMERSON AVEINDRIO RD 940038 2024 11,944 EMERSON RD to SEMINOLE RDINDRIO RD 940281 2024 11,944 SEMINOLE RD to KINGS HWYINDRIO RD 940281 2024 5,763 KINGS HWY to SLASH PINE TRLINDRIO RD 790 364 114 C 0.46 358 C 0.45 2023 5,763 SLASH PINE TRL to US 1INDRIO RD 920 364 114 C 0.40 358 C 0.39 2023 1,070 US 1 to OLD DIXIE HWYINDRIO RD 750 93 672 C 0.12 98 C 0.13 2022 10,986 EDWARDS RD to OKEECHOBEE RDJENKINS RD 880 668 133 C 0.76 678 C 0.77 2024 11,143 OKEECHOBEE RD to GRAHAM RDJENKINS RD 920 593 131 C 0.64 595 C 0.65 2024 6,500 GRAHAM RD to PETERSON RDJENKINS RD 630 357 739 C 0.57 352 C 0.56 2024 6,500 PETERSON RD to ORANGE AVEJENKINS RD 920 357 739 C 0.39 352 C 0.38 2024 4,691 US 1 to LENNARD RDJENNINGS RD 2,100 246 673 C 0.12 234 C 0.11 2022 2,766 ANGLE RD to L20JOHNSTON RD 1,070 217 674 B 0.20 190 B 0.18 2022 2,477 L20 to MEADOWOOD DRJOHNSTON RD 1,070 164 675 B 0.15 155 B 0.14 2022 2,477 MEADOWOOD DR to OLD JOHNSTON RDJOHNSTON RD 1,070 164 675 B 0.15 155 B 0.14 2022 2,477 OLD JOHNSTON RD to INDRIO RDJOHNSTON RD 1,070 164 675 B 0.15 155 B 0.14 2022 9,303 INDRIO RD to RUSSOS RDJOHNSTON RD 1,070 539 135 C 0.50 509 C 0.48 2023 9,303 RUSSOS RD to INDIAN RIVER C.L.JOHNSTON RD 1,070 539 135 C 0.50 509 C 0.48 2023 1,369 53RD ST to 25TH STJUANITA AVE 750 87 122 C 0.12 72 C 0.10 2022 3,445 25TH ST to US 1JUANITA AVE 750 176 120 C 0.23 192 C 0.26 2022 3,109 ANGLE RD to JUANITA AVEKEEN RD 630 227 129 C 0.36 246 C 0.39 2023 3,109 JUANITA AVE to ST LUCIE BLVDKEEN RD 630 227 129 C 0.36 246 C 0.39 2023 9,986 OKEECHOBEE RD to CROSSROADS PKWYKINGS HWY 940757 2024 9,986 CROSSROADS PKWY to GRAHAM RDKINGS HWY 940757 2024 7,196 GRAHAM RD to PICOS RDKINGS HWY 940076 2024 7,196 PICOS RD to ORANGE AVEKINGS HWY 940076 2024 15,122 ORANGE AVE to ANGLE RDKINGS HWY 940077 2024 11,634 ANGLE RD to ST LUCIE BLVDKINGS HWY 940751 2024 14,415 ST LUCIE BLVD to INDRIO RDKINGS HWY 940006 2024 2,369 EDWARDS RD to 35TH STKIRBY LOOP RD 630 137 677 C 0.22 127 C 0.20 2021 3,241 OLEANDER AVE to US 1KITTERMAN RD 750 209 124 C 0.28 170 C 0.23 2023 8 * Volumes shown were adjusted using FDOT Seasonal Factors * AADT = Annual Average Daily Traffic (volumes for both directions where applicable) * NOTE: If the Last Count Year is older than the year of the report, the AADT is projected from historical traffic count data. * NOTE: A six digit number in the "STATION ID" column identifies segment counted by FDOT. Peak hour data is not available for locations on State roads due to differences in data availability, LOS Methodologies, and service level thresholds. Please refer to FDOT sources for detailed data on FDOT traffic counts. Page 290 of 456 St. Lucie TPO Standardized TIS Methodology and Procedures August 2023 B - 1 APPENDIX B AREA OF INFLUENCE A. The area to be studied will be based on the New External Trip Generation of the of influence. New External Daily Trip Generation Radius of Area of Influence 0 200 All site driveway connections and segments directly accessed by the proposed development 201 500 0.5 miles 501 1,000 1.0 miles 1,001 5,000 2.0 miles 5,001 10,000 3.0 miles 10,001 20,000 4.0 miles Over 20,000 5.0 miles B. The radius of influence shall be measured from each connection of the project to the Major Road Network. C. All major signalized and unsignalized intersections on the roadway segments within the area of influence shall be studied. D. If the study radius ends between the intersections identified in above, the study area shall extend to the next major intersection. APPENDIX D Page 291 of 456 2024 PEAK SEASON FACTOR CATEGORY REPORT - REPORT TYPE: ALL CATEGORY: 9401 CEN.-W OF US1 TO I95 MOCF: 0.95 WEEK DATES SF PSCF ================================================================================ 1 01/01/2024 - 01/06/2024 1.00 1.05 2 01/07/2024 - 01/13/2024 0.99 1.04 3 01/14/2024 - 01/20/2024 0.97 1.02 * 4 01/21/2024 - 01/27/2024 0.96 1.01 * 5 01/28/2024 - 02/03/2024 0.95 1.00 * 6 02/04/2024 - 02/10/2024 0.94 0.99 * 7 02/11/2024 - 02/17/2024 0.93 0.98 * 8 02/18/2024 - 02/24/2024 0.93 0.98 * 9 02/25/2024 - 03/02/2024 0.94 0.99 *10 03/03/2024 - 03/09/2024 0.94 0.99 *11 03/10/2024 - 03/16/2024 0.94 0.99 *12 03/17/2024 - 03/23/2024 0.94 0.99 *13 03/24/2024 - 03/30/2024 0.95 1.00 *14 03/31/2024 - 04/06/2024 0.95 1.00 *15 04/07/2024 - 04/13/2024 0.96 1.01 *16 04/14/2024 - 04/20/2024 0.96 1.01 17 04/21/2024 - 04/27/2024 0.98 1.03 18 04/28/2024 - 05/04/2024 1.00 1.05 19 05/05/2024 - 05/11/2024 1.01 1.06 20 05/12/2024 - 05/18/2024 1.03 1.08 21 05/19/2024 - 05/25/2024 1.04 1.09 22 05/26/2024 - 06/01/2024 1.04 1.09 23 06/02/2024 - 06/08/2024 1.05 1.11 24 06/09/2024 - 06/15/2024 1.05 1.11 25 06/16/2024 - 06/22/2024 1.06 1.12 26 06/23/2024 - 06/29/2024 1.06 1.12 27 06/30/2024 - 07/06/2024 1.07 1.13 28 07/07/2024 - 07/13/2024 1.07 1.13 29 07/14/2024 - 07/20/2024 1.08 1.14 30 07/21/2024 - 07/27/2024 1.07 1.13 31 07/28/2024 - 08/03/2024 1.07 1.13 32 08/04/2024 - 08/10/2024 1.06 1.12 33 08/11/2024 - 08/17/2024 1.05 1.11 34 08/18/2024 - 08/24/2024 1.05 1.11 35 08/25/2024 - 08/31/2024 1.05 1.11 36 09/01/2024 - 09/07/2024 1.05 1.11 37 09/08/2024 - 09/14/2024 1.05 1.11 38 09/15/2024 - 09/21/2024 1.05 1.11 39 09/22/2024 - 09/28/2024 1.04 1.09 40 09/29/2024 - 10/05/2024 1.03 1.08 41 10/06/2024 - 10/12/2024 1.01 1.06 42 10/13/2024 - 10/19/2024 1.00 1.05 43 10/20/2024 - 10/26/2024 1.00 1.05 44 10/27/2024 - 11/02/2024 1.00 1.05 45 11/03/2024 - 11/09/2024 1.00 1.05 46 11/10/2024 - 11/16/2024 1.00 1.05 47 11/17/2024 - 11/23/2024 1.00 1.05 48 11/24/2024 - 11/30/2024 1.00 1.05 49 12/01/2024 - 12/07/2024 1.00 1.05 50 12/08/2024 - 12/14/2024 1.00 1.05 51 12/15/2024 - 12/21/2024 1.00 1.05 52 12/22/2024 - 12/28/2024 0.99 1.04 53 12/29/2024 - 12/31/2024 0.97 1.02 * PEAK SEASON 04-MAR-2025 16:32:53 830UPD 4_9401_PKSEASON.TXT APPENDIX E Page 292 of 456 APPENDIX F Page 293 of 456 APPENDIX G Page 294 of 456 Page 295 of 456 Page 296 of 456 Page 297 of 456 Page 298 of 456 Page 299 of 456 Page 300 of 456 Page 301 of 456 Page 302 of 456 Page 303 of 456 Page 304 of 456 Page 305 of 456 Page 306 of 456 Page 307 of 456 7075 Indrio Road TIS Methodology Statement – November 2022 7 TRIP GENERATION METHODOLOGY The purpose of the vehicular trip generation estimate is to approximate the number of new vehicle trips entering and exiting the site for various purposes (e.g., visitor trips, employee, etc.) during a selected time period. The proposed site plan would consist of a multifamily development with 288 dwelling units. The Institute of Transportation Engineers’ (ITE) Trip Generation Manual, 11th Edition was applied for the trip generation analysis because of its widely accepted methodology. It is worth noting, that the land use for a “Multifamily Housing (mid-rise)” (ITE land use 221) was applied for both AM and PM peak hours (based on Dwelling units). Table 1 summarizes the trip generation rates and provides the estimated trip generation for the proposed Project for a typical weekday and the AM and PM peak hours. As shown in Table 1, the Project is estimated to generate 1,327 daily vehicle trips, with 115 of those trips occurring during the AM peak hour, and 113 trips occurring during the PM peak hour upon full buildout of the Project. It is important to note that no pass-by or internal capture reduction rate was applied for this development due to the land use not being eligible for either reduction. Table 1: Trip Generation Rates Source: WGI, 2022 TRIP DISTRIBUTION AND ASSIGNMENT A directional distribution was developed based on the Average Annual Daily Traffic (AADT) volumes of surrounding roadways that connect to Indrio Road. The AADT Volumes were derived from the FDOT online database and they can be seen in Appendix A. The project distribution can be seen below in Table 2. In Out Total In Out Total 1Residential Multifamily Housing (mid-rise)221 288 DU 1,327 26 89 115 69 44 113 1,327 26 89 115 69 44 113 Notes: 1. Daily T= 4.77*(X) - 46.46 AM Peak Hour = 0.44*(X) - 11.61 (23% entering, 77% exiting)PM Peak Hour = 0.39*(X) + 0.34 (61% entering, 39% exiting) DU = Dwelling Units Description Land Use ITE Code Density Weekday AM Peak Weekday PM Peak Daily TotalUnits Total External Net New Vehicle Trips Page 308 of 456 Figure 4Traffic Distribution Kings Hi g h w a y Indrio Road U S 1 18% 22% 24% 28% 8% Key: Project Site N Page 309 of 456 Sabal Palm Grove Traffic Impact Study – December 2023 5 TRIP GENERATION METHODOLOGY The vehicular trip generation estimate aims to approximate the number of new vehicle trips entering and exiting the site for various purposes (e.g., visitor trips, etc.) during a selected time. The Institute of Transportation Engineers (ITE) Trip Generation Manual, 11th Edition was applied for the trip generation analysis because of its widely accepted methodology. The land use “Single-Family Attached Housing” (ITE land use 215) was applied for both AM and PM peak hours (based on dwelling units). TABLE 1: TRIP GENERATION ITE Land Use ITE Code Units (D.U.)¹ Daily Total AM Peak Hour PM Peak Hour In Out Total In Out Total Single Family Attached Housing 215 97 689 11 34 45 32 22 54 External Net New Vehicle Trips 689 11 34 45 32 22 54 Notes: ITE Trip Generation (11th Edition) Land Use Category 215 – Single Family Attached Housing 1. DU = Dwelling Units Daily: T = 7.62*(X)-50.48 AM Peak Hour: T = 0.52*(X)-5.70 (25% in, 75% out) PM Peak Hour: T = 0.60*(X)-3.93 (59% in, 41% out) Source: WGI, 2023. As shown in Table 1, the Project is estimated to generate 689 net new daily external vehicle trips, with 45 new trips occurring during the AM peak hour and 54 new trips occurring during the PM peak hour upon full buildout of the Project. Page 310 of 456 Note: Node 2 was included for reference only. Em e r s o n A v e Lee Blvd Deland Ave Hibiscus Rd Indrio Rd a C C f NB SB WB Em e r s o n A v e EB 58 % 10 % (5 8 % ) a f (10%) 1 3 4 Figure 3: Trip Distribution 23% 68 % 32 % LEGEND Study Area #Intersection #Driveway Global Distribution Local Distribution DIRECTION INTERSECTION Exit Enter XX % (X X % ) WB NB SB Hibiscus Rd 45% a C NB SB WB Em e r s o n A v e EB 58 % 32 % Deland Ave a f c f (58%) (32%) 2 C f a C NB SB WB Le e B l v d EB 10 % a f (5%) (10%) Driveway B a f NB SB WB Dr i v e w a y A EB (8 5 % ) (0 % ) (5%) c f 90% a C Deland Ave Driveway A Driveway B Page 311 of 456 Page 312 of 456 Page 313 of 456 Indrio Groves PUD│Traffic Impact AnalysisAugust2022│Kimley-Horn and Associates, Inc.3 Table 2:Trip Generation Summary (Overall Development) Total In Out Total In Out Proposed Development Single-Family Detached Housing 2,036 DU 16,143 1,156 301 855 1,689 1,064 625 Multifamily Housing (Low-Rise)964 DU 6,255 322 77 245 435 274 161 22,398 1,478 378 1,100 2,124 1,338 786 22,398 1,478 378 1,100 2,124 1,338 786 Single-Family Detached Housing [ITE 210] Daily Ln(T) = 0.92*Ln(X) +2.68; (X is number of dwelling units) AM Peak Hour of Adjacent Street Ln(T) = 0.91*Ln(X) + 0.12; (X is number of dwelling units); (26% in/74% out) PM Peak Hour of Adjacent Street Ln(T) = 0.94*Ln(X) + 0.27; (X is number of dwelling units); (63% in/37% out) Multifamily Housing (Low-Rise) [ITE 220] Daily T = 6.41*(X) + 75.31; (X is number of dwelling units) AM Peak Hour of Adjacent Street T = 0.31*(X) + 22.85; (X is number of dwelling units); (24% in/76% out) PM Peak Hour of Adjacent Street T = 0.43*(X) + 20.55; (X is number of dwelling units); (63% in/37% out) AM Peak Hour of Adjacent Street PM Peak Hour of Adjacent Street Subtotal Land Use Intensity Daily TOTAL NET NEW EXTERNAL TRIPS Trip Generation was calculated using the data from ITE's Trip Generation Manual, 11th Edition. Page 314 of 456 N NOT TO SCALE Figure 1a:Project Trip Distribution 6© 2022 Kimley-Horn and Associates, Inc.189 S Orange Ave, Suite 1000, Orlando, FL, 32801Phone: (407)-898-1511 August 2022 Project No.: 147410001 1INDRIO RD 25% Indrio Groves PUD 3 4 5 6 7 8 9 30% 6%2% 1% 10% 15%4% KO B L E G A R D R D JO H N S T O N R D EM E R S O N A V E KI N G S H W Y 2 5 INDRIO RD KO B L E G A R D R D 4 3 SPANISHLAKES BLVD JO H N S T O N R D 6% LEGEND Project Location % Project Trips In % Project Trips Out % Project Distribution Study Intersection Project Driveway XX% # # INDRIO RD INDRIO RD Aerial imagery provided by: KO B L E G A R D R D 55 % 38 % 55% 53 % 40 % 40% 53 % 28% 6% 28%4% 4% 2 1 I- 9 5 S O U T H B O U N D INDRIO RD 25 % I- 9 5 N O R T H B O U N D 30 % 25% 30%25% 30%38% TURNPIKE FEEDER RD 7% 26%28%38% 40% 53% Page 315 of 456 N NOT TO SCALE Figure 1b:Project Trip Distribution 7© 2022 Kimley-Horn and Associates, Inc.189 S Orange Ave, Suite 1000, Orlando, FL, 32801Phone: (407)-898-1511 August 2022 Project No.: 147410001 INDRIO RD 25% 3 4 5 6 7 8 9 30% 6%2% 1% 10% 15%4% KI N G S H W Y 6 9 EM E R S O N A V E INDRIO RD KI N G S H W Y 87 SP A N I S H LA K E S B L V D 2% 26% 2%26% 10% INDRIO RD Aerial imagery provided by: PROJECT DRWY #1 PROJECT DRWY #2 1% 15 % 40 % 40% 53 % KO B L E G A R D R D KO B L E G A R D R D JO H N S T O N R D EM E R S O N A V E 1% 10% 15% LEGEND Project Location % Project Trips In % Project Trips Out % Project Distribution Study Intersection Project Driveway XX% # # 1 2 TU R N P I K E FE E D E R R D 7% 7% 53% 7% Indrio Groves PUD 26%28%38% 40% 53% Page 316 of 456 160004 Page 3 Table 1. Trip Generation Land Use Intensity Daily AM Peak Hour PM Peak Hour Trips Total In Out Total In Out Proposed Phase I - Site Traffic Single Family Detached 1,763 DU 14,140 1,014 264 750 1,475 929 546 Multifamily Housing(Low-Rise)755 DU 4,915 257 62 195 345 217 128 General Office 560 1000 SF 5,194 737 649 88 694 118 576 Shopping Center (>150k)400 1000 SF 16,308 370 229 141 1,531 735 796 Subtotal 40,557 2,378 1,204 1,174 4,045 1,999 2,046 Internal Capture AM DAILY Single Family Detached 3.5%21.7%3,068 35 7 28 320 219 101 Multifamily Housing(Low-Rise)0.0%0.0%0 0 0 0 0 0 0 General Office 9.5%16.4%853 70 45 25 114 43 71 Shopping Center (>150k)18.1%23.3%3,792 67 34 33 356 133 223 Subtotal 7,713 172 86 86 790 395 395 Pass-By Traffic Single Family Detached 0.0%0 0 0 0 0 0 0 Multifamily Housing(Low-Rise)0.0%0 0 0 0 0 0 0 General Office 0.0%0 0 0 0 0 0 0 Shopping Center (>150k)19.0%2,378 58 37 21 223 114 109 10% of Adj Street* Subtotal 2,378 58 37 21 223 114 109 30,466 2,148 1,081 1,067 3,032 1,490 1,542 32,844 2,206 1,118 1,088 3,255 1,604 1,651 Note: Trip generation was calculated using the following data: Pass-by PM Peak Hour Land Use Unit Daily Rate Rate in/out in/out Equation 210 DU 0%26/74 63/37 220 DU 0%24/76 63/37 710 1000 SF 34%88/12 17/83 820 1000 SF 0%62/38 48/52 ITE 11th Edition Copyright © 2024, MacKenzie Engineering and Planning, Inc. * Pass by will be limited to 10% of the Adjacent Street Shopping Center (>150k)T = 26.11 (X) + 5863.73 T = 0.59 (X) + 133.55 Ln(T) = 0.72 Ln(X) + 3.02 Multifamily Housing(Low- Rise)T = 6.41 (X) + 75.31 T = 0.31 (X) + 22.85 T = 0.43 (X) + 20.55 General Office Ln(T) = 0.87 Ln(X) + 3.05 Ln(T) = 0.86 Ln(X) + 1.16 Ln(T) = 0.83 Ln(X) + 1.29 PM/ NET CHANGE IN DRIVEWAY VOLUMES NET CHANGE IN TRIPS (FOR THE PURPOSES OF CONCURRENCY) Single Family Detached Ln(T) = 0.92 Ln(X) + 2.68 Ln(T) = 0.91 Ln(X) + 0.12 Ln(T) = 0.94 Ln(X) + 0.27 ITE Code AM Peak Hour Rate Indrio & I-95 Page 317 of 456 160004 Page 6 TRAFFIC DISTRIBUTION AND ASSIGNMENT The project's traffic assignment is based on outputs from the 2045 TCRPM 5.1 model. The assignment was modified to reflect the project's access and the existing roadway network. The overall distribution is summarized by general directions and is depicted below: NORTH - 25 percent SOUTH - 12 percent EAST - 26 percent WEST - 37 percent Figure 3. Assignment Map ` 1% 2% 2% 1% 17% 18% 14% 2% 4% 6% 5% 36% 28% 26% 20% 2% 18% 6% 4% 3% 7% 4% 3% 1% 7% 7% 5% 1% 7% 6% 27% 12% 3% 25% 25% 1% 1% 3% 7% 1% 3% 3% 2% 1% 1% 1% 17% 0% 0% 1% Indrio & I-95 Page 318 of 456 AM PEAK HOUR TURNING MOVEMENTS & Count Taken:2/7/2024 ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr totals7:00 AM 7:15 AM 0 2 120 0 0 0 159 0 0 0 0 0 0 11 0 10 3027:15 AM 7:30 AM 0 1 184 0 0 0 157 0 0 0 0 0 0 11 0 9 3627:30 AM 7:45 AM 0 1 167 0 0 0 229 0 0 0 0 0 0 14 0 14 425 7:45 AM 8:00 AM 0 8 169 0 0 0 170 0 0 0 0 0 0 20 0 9 376 8:00 AM 8:15 AM 0 2 133 0 0 0 159 0 0 0 0 0 0 24 0 12 3308:15 AM 8:30 AM 0 4 130 0 0 0 157 0 0 0 0 0 0 18 0 10 3198:30 AM 8:45 AM 0 8 120 0 0 0 160 0 0 0 0 0 0 35 0 9 3328:45 AM 9:00 AM 0 6 111 0 0 0 135 0 0 0 0 0 0 37 0 17 306 0 32 1134 0 0 0 1326 0 0 0 0 0 0 170 0 90 2752 7:15 AM 8:15 AM 0 12 653 0 0 0 715 0 0 0 0 0 0 69 0 44 1493 Count Taken:2/8/2024 ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr totals 7:00 AM 7:15 AM 0 3 127 0 0 0 167 0 0 0 0 0 0 16 0 13 3267:15 AM 7:30 AM 0 2 139 0 0 0 232 0 0 0 0 0 0 9 0 9 3917:30 AM 7:45 AM 0 4 185 0 0 0 245 0 0 0 0 0 0 18 0 15 4677:45 AM 8:00 AM 0 5 169 0 0 0 216 0 0 0 0 0 0 12 0 10 412 8:00 AM 8:15 AM 1 9 141 0 0 0 155 0 0 0 0 0 0 16 0 17 339 8:15 AM 8:30 AM 1 9 138 0 0 0 161 0 0 0 0 0 0 19 0 8 3368:30 AM 8:45 AM 0 2 112 0 0 0 141 0 0 0 0 0 0 23 0 6 2848:45 AM 9:00 AM 2 4 137 0 1 0 121 0 0 0 0 0 0 33 0 11 309438114801014380000001460892864 7:15 AM 8:15 AM 1 20 634 0 0 0 848 0 0 0 0 0 0 55 0 51 1609 7:15 AM 8:15 AM 1 20 634 0 0 0 848 0 0 0 0 0 0 55 0 51 1609 Count Taken:2/8/2024Buildout year:2035Growth Rate:3.2%1.0% PSCF:1.00 PHF 0.86 Adjusted PHF 0.92 ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr2/8/2024 1 20 634 0 0 0 848 0 0 0 0 0 0 55 0 51PSCF0000000000000000Adjusted Volumes 21 634 0 0 848 0 0 0 0 55 0 51 Growth Rate 3.2%3.2%3.2%3.2%3.2%3.2%3.2%3.2%3.2%3.2%3.2%3.2%2035 Growth 9 263 0 0 351 0 0 0 0 23 0 21Growth 3.2%30 897 0 0 1199 0 0 0 0 78 0 72 Growth Rate 1.0%1.0%1.0%1.0%1.0%1.0%1.0%1.0%1.0%1.0%1.0%1.0%2035 Growth 2 73 0 0 98 0 0 0 0 6 0 6Growth 1%23 707 0 0 946 0 0 0 0 61 0 57 COMMITTED PROJECTS Publix at Indrio AM IN 65 OUT 53In/Out In Out Out In%0%0%7%0%0%0%7%1%0%0%0%0%0%1%0%0%Volumes 0 0 5 0 0 0 4 1 0 0 0 0 0 1 0 0 Indrio Woods AM IN 26 OUT 89 In/Out%0%0%0%0%0%0%0%0%0%0%0%0%0%0%0%0%Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Sabal Palm Grove AM IN 11 OUT 34 In/Out %0%0%0%0%0%0%0%0%0%0%0%0%0%0%0%0%Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Cabo Rio RV Resort AM IN 15 OUT 27In/Out %0%0%0%0%0%0%0%0%0%0%0%0%0%0%0%0% Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Bedner Farms AM IN 331 OUT 519Volumes0126000 47 105 131 0 0 0 0 0 291 0 137Buc-ee's Net Change Volumes 7 68 54 54 Pass-By Volumes -31 3 31 -31 30 31Diverted Volumes 51 478Buc-ee's Volumes 0 0 -31 61 0 99 -31 0 0 562 0 85 0 0 0 0 Total Committed 0 126 -26 61 0 146 78 132 0 562 0 85 0 292 0 137Committed + 1%0 149 681 61 0 146 1024 132 0 562 0 85 0 353 0 194 Growth 3.2% or Committed + 1%149 897 61 146 1199 132 562 0 85 353 0 194 2035 Pre-Development 149 897 61 146 1199 132 562 0 85 353 0 194 Net Change Volumes 216 184 54 213 22 182 53 54 22 54 Pass-By Volumes 15 7 1 Total Project Volumes 0 231 184 54 220 22 183 53 54 22 54 0 2035 Post-Development 149 1128 245 200 1419 154 745 53 139 375 54 194 Existing % TrucksCommitted/Growth/Project % Trucks Pre-Development % Trucks Future % Trucks AM Peak Hour Indrio Road Traffic Volume from I-95 to Koblegard Road Eastbound = EBL + EBT + EBR = 21 +634 +0 =655Westbound = NBL + WBT + SBR = 0 +848 +51 =899 AM Peak Hour Indrio Road Traffic Volume from Koblegard Road to Johnston Road Eastbound = SBL + EBT + NBR = 55 +634 +0 =689Westbound = WBL + WBT + WBR = 0 +848 +0 =848 EXHIBIT 4E Indrio Rd & I-95 Koblegard Rd (DW 1)Indrio Rd Peak Hour Traffic Volume Peak Hour Traffic Volume Maximum Peak Hour Traffic Volume 6.9%7.0%0.0% 4.9%4.9%2.0% 2.0%2.0%2.0%2.0%0.9% 1.8% 4.1%4.4%2.0%1.8% Indrio & I-95 Page 319 of 456 PM PEAK HOUR TURNING MOVEMENTS &Count Taken:2/7/2024 ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr totals 4:00 PM 4:15 PM 2 18 161 0 0 0 141 0 0 0 0 0 0 17 0 6 3454:15 PM 4:30 PM 0 12 177 0 0 0 160 0 0 0 0 0 0 16 0 6 3714:30 PM 4:45 PM 0 13 209 0 0 0 179 0 0 0 0 0 0 22 0 19 442 4:45 PM 5:00 PM 1 14 206 0 0 0 153 0 0 0 0 0 0 20 0 10 4045:00 PM 5:15 PM 0 12 222 0 2 0 166 0 0 0 0 0 0 18 0 9 4295:15 PM 5:30 PM 1 13 190 0 0 0 169 0 0 0 0 0 0 16 0 10 399 5:30 PM 5:45 PM 1 13 209 0 0 0 149 0 0 0 0 0 0 17 0 15 4045:45 PM 6:00 PM 0 3 141 0 0 0 141 0 0 0 0 0 0 16 0 18 319598151502012580000001420933113 4:30 PM 5:30 PM 2 52 827 0 2 0 667 0 0 0 0 0 0 76 0 48 1674 Count Taken:2/8/2024 ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr totals4:00 PM 4:15 PM 0 11 184 0 0 0 161 0 0 0 0 0 0 12 0 6 374 4:15 PM 4:30 PM 0 12 183 0 0 0 148 0 0 0 0 0 0 11 0 9 3634:30 PM 4:45 PM 0 16 198 0 0 0 181 0 0 0 0 0 0 24 0 5 4244:45 PM 5:00 PM 0 9 210 0 0 0 169 0 0 0 0 0 0 18 0 4 410 5:00 PM 5:15 PM 0 7 216 0 0 0 172 0 0 0 0 0 0 14 0 2 411 5:15 PM 5:30 PM 0 9 219 0 0 0 183 0 0 0 0 0 0 13 0 4 4285:30 PM 5:45 PM 0 9 173 0 0 0 165 0 0 0 0 0 0 15 0 6 3685:45 PM 6:00 PM 0 11 150 0 0 0 124 0 0 0 0 0 0 18 0 4 307 0 84 1533 0 0 0 1303 0 0 0 0 0 0 125 0 40 3085 4:30 PM 5:30 PM 0 41 843 0 0 0 705 0 0 0 0 0 0 69 0 15 1673 4:30 PM 5:30 PM 2 52 827 0 2 0 667 0 0 0 0 0 0 76 0 48 1674 Count Taken:2/8/2024Buildout year:2035 Growth Rate:3.2%1.0%PSCF:1.00PHF0.95 Adjusted PHF 0.95 ebu ebl ebt ebr wbu wbl wbt wbr nbu nbl nbt nbr sbu sbl sbt sbr2/8/2024 2 52 827 0 2 0 667 0 0 0 0 0 0 76 0 48PSCF0000000000000000 Adjusted Volumes 54 827 0 2 667 0 0 0 0 76 0 48 Growth Rate 3.2%3.2%3.2%3.2%3.2%3.2%3.2%3.2%3.2%3.2%3.2%3.2% 2035 Growth 4 54 0 0 43 0 0 0 0 5 0 3Growth 3.2%58 881 0 2 710 0 0 0 0 81 0 51 Growth Rate 1.0%1.0%1.0%1.0%1.0%1.0%1.0%1.0%1.0%1.0%1.0%1.0%2035 Growth 1 17 0 0 13 0 0 0 0 2 0 1 Growth 1%55 844 0 2 680 0 0 0 0 78 0 49COMMITTED PROJECTSPublix at Indrio PM IN 136 OUT 142 In/Out In Out Out In%0%0%7%0%0%0%7%1%0%0%0%0%0%1%0%0%Volumes 0 0 10 0 0 0 10 1 0 0 0 0 0 1 0 0 Indrio Woods PM IN 69 OUT 44In/Out%0%0%0%0%0%0%0%0%0%0%0%0%0%0%0%0% Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Sabal Palm Grove PM IN 32 OUT 22In/Out %0%0%0%0%0%0%0%0%0%0%0%0%0%0%0%0%Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Cabo Rio RV Resort PM IN 36 OUT 19 In/Out %0%0%0%0%0%0%0%0%0%0%0%0%0%0%0%0%Volumes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Bedner Farms PM IN 816 OUT 691 Volumes 0 319 0 0 0 22 251 311 0 0 0 0 0 475 0 144Buc-ee'sNet Change Volumes 9 97 76 77 Pass-By Volumes -31 3 31 -31 30 31Diverted Volumes 68 579Buc-ee's Volumes 0 0 -31 80 0 128 -31 0 0 685 0 108 0 0 0 0 Total Committed 0 319 -21 80 0 150 230 312 0 685 0 108 0 476 0 144Committed + 1%0 374 823 80 0 152 910 312 0 685 0 108 0 554 0 193 Growth 3.2% or Committed + 1%374 881 80 152 910 312 685 0 108 554 0 193 2035 Pre-Development 374 881 80 152 910 312 685 0 108 554 0 193 Project Volumes 298 254 75 308 31 262 77 78 30 74Pass-By Volumes 46 38 6 Total Project Volumes 0 344 254 75 346 31 268 77 78 30 74 0 2035 Post-Development 374 1225 334 227 1256 343 953 77 186 584 74 193 Existing % Trucks Committed/Growth/Project % TrucksPre-Development % TrucksFuture % Trucks PM Peak Hour Indrio Road Traffic Volume from I-95 to Koblegard Road Eastbound = EBL + EBT + EBR = 54 +827 +0 =881Westbound = NBL + WBT + SBR = 0 +667 +48 =715 PM Peak Hour Indrio Road Traffic Volume from Koblegard Road to Johnston Road Eastbound = SBL + EBT + NBR = 76 +827 +0 =903Westbound = WBL + WBT + WBR = 2 +667 +0 =669 PM Peak Hour Koblegard Road Traffic Volume from Indrio Road to 25th Street SW Northbound = EBL + NBT + WBR =54 +0 +0 =54Southbound = SBR + SBT + SBL =76 +0 +48 =124 EXHIBIT 4F Maximum Peak Hour Traffic Volume 5.2%3.1%0.0% 4.1%2.5%2.0% Indrio Rd & I-95 1.2% 2.0%1.9% Koblegard Rd (DW 1)Indrio Rd Peak Hour Traffic Volume Peak Hour Traffic Volume 3.5%2.4%2.0%1.9% 2.0%2.0%2.0% Indrio & I-95 Page 320 of 456 252001 Page 2 TRIP GENERATION Trip Generation Manual (11th Edition). Proposed Use 955 dwelling units (DU) Single Family Detached (ITE Land Use 210) 758 dwelling units (DU) Multi-family Housing (Low-Rise) (ITE Land Use 220) The proposed development will generate the following net new external and cumulative driveway trips: 12,979 daily, 839 AM peak hour (207 in/632 out), and 1,175 PM peak hour (740 in/435 out) trips. Table 1 Table 1. Trip Generation Land Use Daily AM Peak Hour PM Peak Hour Trips Total In Out Total In Out Proposed Traffic 955 DU 8,045 581 145 436 829 522 307 Multi-family Housing (Low-rise)758 DU 4,934 258 62 196 346 218 128 12,979 839 207 632 1,175 740 435 12,979 839 207 632 1,175 740 435 Note: Trip generation was calculated using the following data: Pass-by PM Peak Hour Land Use ITE Code Unit Daily Rate Rate in/out in/out Equation 210 DU 0% 25/75 63/37 220 DU 0% 24/76 63/37 ITE 11th Edition Copyright © 2024, MacKenzie Engineering and Planning, Inc. Single Family Detached NET CHANGE IN TRIPS (FOR THE PURPOSES OF CONCURRENCY) NET CHANGE IN DRIVEWAY VOLUMES AM Peak Hour Intensity Rate Single Family Detached Ln(T) = 0.92 Ln(X) + 2.68 Ln(T) = 0.91 Ln(X) + 0.12 Ln(T) = 0.94 Ln(X) + 0.27 Multi-family Housing (Low-rise)T = 6.41(X) + 75.31 T = 0.31(X) + 22.85 T = 0.43(X) + 20.55 Eagle-Bend Page 321 of 456 252001 Page 7 TRAFFIC ASSIGNMENT The distributed net proposed trips for the project were assigned to the roadway network within the radius of influence. The project assignments are illustrated in Figure 3A and Figure 3B for Scenarios 1 and 2, respectively. Figure 3C (Scenario 1) shows the intersection assignment. Figure 3D (Scenario 2) shows the projected assignment if Road G connects to Kings Highway. Figure 3A. Traffic Assignment (Scenario 1) Page 322 of 456 293002 Page 3 Table 1. Trip Generation Internal and Pass-by Capture Internal and pass-by capture are 0%. 2098 Johnston Road Page 323 of 456 293002 Page 6 TRAFFIC DISTRIBUTION Traffic distribution and assignment was developed based upon a select zone assignment for the project using the peak hour traffic counts. The resulting traffic assignment is representative of the distribution and assignment based on existing traffic counts. The overall distribution is summarized by general directions below: NORTH - 34 percent SOUTH - 66 percent TRAFFIC ASSIGNMENT The distributed net proposed trips for the project were assigned to the roadway network within the radius of influence. The project assignments are illustrated in Figure 3. Figure 3. Traffic Assignment Orange Ave Angle Rd Angle Rd 34% 22% 7% 5% 32%66%44% 34% 1-Mile Radius Study Area Indrio Rd 27%2% 5% Page 324 of 456 Page 325 of 456 Page 326 of 456 Page 327 of 456 Page 328 of 456 Page 329 of 456 160004 Page 3 Table 1. Trip Generation Site (Buc- Land Use Intensity Daily AM Peak Hour PM Peak Hour Trips Total In Out Total In Out Outparcels Land Use Hotel 120 Rooms 877 53 30 23 61 31 30 Drive-in Bank 5.000 1000 SF 502 50 29 21 105 53 52 High-Turnover (Sit-Down) Restaurant 10.000 1000 SF 1,072 96 53 43 91 56 35 Buc-ee's 120 F.P. 20,621 1,042 531 511 1,378 675 703 Subtotal 23,072 1,241 643 598 1,635 815 820 Internal Capture AM DAILY Hotel 5.7% 8.2% 72 3 1 2 5 2 3 Drive-in Bank 0.0% 0.0% 0 0 0 0 0 0 0 High-Turnover (Sit-Down) Restaurant 3.1% 5.5% 59 3 2 1 5 3 2 Subtotal 0.5% 0.6% 131 6 3 3 10 5 5 PM/ Pass-By Traffic (ITE)AM DAILY Hotel 0% 0% 0 0 0 0 0 0 0 Drive-in Bank 29% 35% 146 15 8 7 30 15 15 High-Turnover (Sit-Down) Restaurant 43% 43% 436 40 22 18 37 23 14 Subtotal 582 55 30 25 67 38 29 Pass-By Trips (10% of Adj Street*)1,510 155 78 77 160 80 80 Use Lowest Pass-By Traffic 582 55 30 25 67 38 29 17,528 830 423 407 1,171 574 597 22,359 1,180 610 570 1,558 772 786 22,941 1,235 640 595 1,625 810 815 Note: Trip generation was calculated using the following data: Pass-by PM Peak Hour Land Use Unit Daily Rate Rate in/out in/out Equation 310 Rooms 0% 56/44 51/49 912 1000 SF 29/35 58/42 50/50 932 1000 SF 43% 55/45 61/39 BUC F.P.0.00 51/49 49/51Buc-ee's 171.84 8.68 11.48 T = 0.74(X) - 27.89 Drive-in Bank 100.35 9.95 21.01 High-Turnover (Sit-Down) Restaurant 107.2 9.57 9.05 ITE Code AM Peak Hour Rate Hotel T = 10.84(X) - 423.51 T = 0.50(X) - 7.45 NET CHANGE IN TRIPS DRIVEWAY TRIPS I-95 DIVERTED TRIPS PM/ BUC-EE'S Page 330 of 456 160004 Page 7 Figure 2. Assignment Map ` 85%13.5% 1% 1.5% Project Site 2.5% 4.5% 6.5% 5%4% 1.5% 0.3% 2% 1% 1% 0.3%1% 1.5% 7.3% 2.3% 2% 4% 3% Indrio RoadSR 614 I-95 I-95 St. Lucie Blvd Angle Rd Oslo Road BUC-EE'S Page 331 of 456 160004 Page 9 Figure 3. Project Distribution Map BUC-EE'S Page 332 of 456 160004 Page 10 Figure 4. Project Distribution Map BUC-EE'S Page 333 of 456 160004 Page 11 Figure 5. Peak hour Project Trips Page 334 of 456 160004 Page 12 Figure 6. Peak hour Project Trips Page 335 of 456 CABO RIO RV RESORT TRAFFIC IMPACT STUDY Prepared for CABO RIO, LLC Prepared by PINDER TROUTMAN CONSULTING, INC. Certificate of Authorization Number: 7989 2005 Vista Parkway, Suite 111 West Palm Beach, FL 33411 (561) 296-9698 #PTC20-117 March 17, 2021 Rebecca J. Mulcahy, State of Florida, Professional Engineer, License No. 42570 This item has been electronically signed and sealed by Rebecca J. Mulcahy, P.E. on 3/17/21 using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Page 336 of 456 Page 337 of 456 Assign 20-117 3-11-21 3/16/2021Exhibit 3B Cabo Rio RV Resort Project Traffic Assignment AM Peak 15 In Total Significant Existing 27 Out Project Service Impact? Roadway Link Lanes Dir % Dist Trips Impact Volume (1)(Yes/No) EB 41%6 0.19%3240 No WB 41%11 0.34%3240 No EB 45%7 0.76%920 No WB 45%12 1.30%920 No EB 45%7 0.89%790 No WB 45%12 1.52%790 No EB 15%4 0.51%790 No WB 15%2 0.25%790 No EB 15%4 0.43%920 No WB 15%2 0.22%920 No NB 4%1 0.08%1190 No SB 4%1 0.08%1190 No NB 25%4 0.48%830 No SB 25%7 0.84%830 No NB 75%20 1.05%1910 YES SB 75%11 0.58%1910 No NB 15%4 0.46%870 No SB 15%2 0.23%870 No NB 15%4 0.46%870 No SB 15%2 0.23%870 No (1) Based on St. Lucie County TPO Fall/Winter 2019/2020 Traffic Counts and Level of Service Report. See Appendix B. (2) First accessed roadway link. Indrio Road Johnston Road to Emerson Avenue 2L Seminole Road to Kings Highway 2L Project Traffic 4LD Slash Pine Trail to US 1 2L Emerson Avenue to Seminole Road Kings Highway to Slash Pine Trail (2) 2L Emerson Avenue Indrio Road to County Line 2L Kings Highway 4LD 2L 2L Indrio Road to Indian Pines Blvd St. Lucie Boulevard to Site (2) Turnpike Feeder Rd/SR 713 Indian Pines Blvd to Turnpike Feeder Rd SB 2L Site to Indrio Road (2) Page 338 of 456 Assign 20-117 3-11-21 3/16/2021Exhibit 3C Cabo Rio RV Resort Project Traffic Assignment PM Peak 36 In Total Significant Existing 19 Out Project Service Impact? Roadway Link Lanes Dir % Dist Trips Impact Volume (1)(Yes/No) EB 41%15 0.46%3240 No WB 41%8 0.25%3240 No EB 45%16 1.74%920 No WB 45%9 0.98%920 No EB 45%16 2.03%790 No WB 45%9 1.14%790 No EB 15%3 0.38%790 No WB 15%5 0.63%790 No EB 15%3 0.33%920 No WB 15%5 0.54%920 No NB 4%1 0.08%1190 No SB 4%1 0.08%1190 No NB 25%9 1.08%830 YES SB 25%5 0.60%830 No NB 75%14 0.73%1910 No SB 75%27 1.41%1910 YES NB 15%3 0.34%870 No SB 15%5 0.57%870 No NB 15%3 0.34%870 No SB 15%5 0.57%870 No (1) Based on St. Lucie County TPO Fall/Winter 2019/2020 Traffic Counts and Level of Service Report. See Appendix B. (2) First accessed roadway link. Project Traffic Indrio Road Johnston Road to Emerson Avenue 4LD Emerson Avenue to Seminole Road 2L Seminole Road to Kings Highway 2L Kings Highway to Slash Pine Trail (2)2L Slash Pine Trail to US 1 2L Emerson Avenue Indrio Road to County Line 2L St. Lucie Boulevard to Site (2)2L Turnpike Feeder Rd/SR 713 Indrio Road to Indian Pines Blvd 2L Indian Pines Blvd to Turnpike Feeder Rd SB 2L Site to Indrio Road (2)4LD Kings Highway Page 339 of 456 Intersections 20-117 3-11-21 Historic Growth Rate =2.52% Peak Season =1.00 Buildout Year = 2024 Years =3 Northbound Southbound Eastbound Westbound LT Thru RT LT Thru RT LT Thru RT LT Thru RT Existing Volume (1/26/21)177 353 21 106 360 175 185 138 213 66 125 36 Peak Season Volume 177 353 21 106 360 175 185 138 213 66 125 36 Historic Growth 14 27 2 8 28 14 14 11 17 5 10 3 Total Background Traffic 191 380 23 114 388 189 199 149 230 71 135 39 % Project Traffic 45%15%15%0%15%0%0%0%45%15%0%0% Direction out out out in in in in in in in in in Project Traffic 12 4 4 0 2 0 0 0 7 2 0 0 Total 203 384 27 114 390 189 199 149 237 73 135 39 Northbound Southbound Eastbound Westbound LT Thru RT LT Thru RT LT Thru RT LT Thru RT Existing Volume (1/26/21)312 386 60 98 296 175 189 160 143 58 220 128 Peak Season Volume 312 386 60 98 296 175 189 160 143 58 220 128 Historic Growth 24 30 5 8 23 14 15 12 11 4 17 10 Total Background Traffic 336 416 65 106 319 189 204 172 154 62 237 138 % Project Traffic 45%15%15%0%15%0%0%0%45%15%0%0% Direction out out out in in in in in in in in in Project Traffic 9 3 3 0 5 0 0 0 16 5 0 0 Total 345 419 68 106 324 189 204 172 170 67 237 138 3/16/2021 10:41 Intersection Volume Development PM Peak Hour AM Peak Hour Intersection Volume Development INTERSECTION ANALYSIS SHEET Cabo Rio RV Resort Indrio Rd & Kings Hwy (Existing Geometrics w/Project) Page 340 of 456 NVR Fort Pierce Traffic Impact Analysis May 2024 Kimley-Horn and Associates, Inc.9 3.0 DEVELOPMENT TRAFFIC 3.1 TRIP GENERATION Trip generation for the proposed project was calculated per procedures published in the 11th Edition of the Institute of Transportation Engineers’ (ITE)Trip Generation Manual. The Land Use Codes (LUCs) used for the proposed site are: LUC 210, Single-Family Detached Housing LUC 215, Single-Family Attached Housing Table 6 provides the Daily, AM peak hour, and PM peak hour trip generation summary for the project. Relevant excerpts from the ITE Trip Generation Manual are included in Appendix B. Table 6:Trip Generation Summary Total In Out Total In Out Proposed Development Single-Family Detached Housing 219 DU 2,075 152 40 112 208 131 77 Single-Family Attached Housing 339 DU 2,533 171 53 118 199 97 102 4,608 323 93 230 407 228 179 4,608 323 93 230 407 228 179 Single-Family Detached Housing [ITE 210] Daily Ln(T) = 0.92*(X)+2.68; (X is number of dwelling units) AM Peak Hour of Adjacent Street Ln(T) = 0.91*(X)+0.12; (X is number of dwelling units); (26% in/ 74% out) PM Peak Hour of Adjacent Street Ln(T) = 0.94*(X)+0.27; (X is number of dwelling units); (63% in/ 37% out) Single-Family Attached Housing [ITE 215] Daily T = 7.62*(X)-50.48; (X is number of dwelling units) AM Peak Hour of Adjacent Street T = 0.52*(X)-5.70; (X is number of dwelling units); (31% in/ 69% out) PM Peak Hour of Adjacent Street T = 0.60*(X)-3.93; (X is number of dwelling units); (57% in/ 43% out) Subtotal Note 1: Trip Generation was calculated using the data from ITE's Trip Generation Manual, 11th Edition TOTAL NET EXTERNAL TRIPS PM Peak Hour of Adjacent StreetLand Use Intensity Daily Trips AM Peak Hour of Adjacent Street NVR FORT PIERCE Page 341 of 456 JO H N S T O N R D KI N G S H W Y 23 % 97 % 3% JO H N S T O N R D 13 % 21 % KI N G S H W Y 13 % 7% 13 %1% KI N G S H W Y DR W Y 2 97 % 3% DR W Y 1 Page 342 of 456 JO H N S T O N R D KI N G S H W Y (5 2 ) 2 1 10 9 ( 7 5 ) 3 ( 2 ) JO H N S T O N R D (3 0 ) 1 2 20 ( 4 8 ) KI N G S H W Y 12 ( 3 0 ) (1 3 ) 1 6 (2 3 ) 3 0 (2 ) 2 KI N G S H W Y DR W Y 2 11 4 ( 9 9 ) 4 ( 3 ) DR W Y 1 Page 343 of 456 NVR Fort Pierce Traffic Impact Analysis May 2024 Kimley-Horn and Associates, Inc.3 Table 1:Study Area Determination To Volume LOS V/C Volume LOS V/C Orange Avenue Avenue D 8,603 790 421 D 0.53 404 D 0.51 25%57 7.2% Avenue D Avenue Q 8,603 540 421 D 0.78 404 D 0.75 26%59 10.9% Avenue Q 53rd Street 8,700 600 583 D 0.97 524 D 0.87 34%78 13.0% 53rd Street Keen Road 6,000 630 378 C 0.60 325 C 0.52 37%84 13.3% Keen Road Kings Highway 6,000 880 378 C 0.43 325 C 0.37 40%91 10.3% Kings Highway Johnston Road 5,758 1,070 358 B 0.34 344 B 0.32 74%169 15.8% Johnston Road Florida's Turnpike 2,028 1,070 96 B 0.09 96 B 0.09 97%221 20.7% Cortez Blvd Virginia Avenue 22,500 2,000 1,324 C 0.66 1,090 C 0.55 3%3 0.2% Virginia Avenue Nebraska Avenue 22,168 2,000 1,082 C 0.54 1,082 C 0.54 3%3 0.2% Nebraska Avenue Okeechobee Road 22,168 2,000 1,082 C 0.54 1,082 C 0.54 6%7 0.3% Okeechobee Road Georgia Avenue 21,986 1,630 1,016 D 0.62 1,053 D 0.54 8%9 0.5% Georgia Avenue Delaware Avenue 219,886 1,630 1,016 D 0.62 1,053 D 0.65 2%2 0.1% Delaware Avenue Orange Avenue 21,569 1,630 1,053 D 0.65 1,053 D 0.65 2%2 0.1% Orange Avenue Avenue D 23,000 1,630 1,145 D 0.70 1,325 D 0.81 0%0 0.0% Avenue D Avenue Q 17,945 1,630 876 D 0.54 876 D 0.54 1%1 0.1% Avenue Q Juanita Ave 16,821 2,000 821 C 0.41 821 C 0.41 0%0 0.0% Okeechobee Road Delaware Avenue 7,200 750 408 D 0.54 366 C 0.49 8%9 1.2% Delaware Avenue Orange Avenue 6,285 790 290 C 0.37 290 C 0.37 16%18 2.3% Angle Road L20 2,909 1,070 228 B 0.21 200 B 0.19 22%50 4.7% L20 Meadowood Drive 2,604 1,070 172 B 0.16 163 B 0.15 8%18 1.7% Meadowood Drive Old Johnston Road 2,604 1,070 172 B 0.16 163 B 0.15 7%16 1.5% Old Johnston Road Indrio Road 2,604 1,070 172 B 0.16 163 B 0.15 7%16 1.5% Okeechobee Road Crossroads Pkwy 9,383 880 472 C 0.54 472 C 0.54 4%9 1.0% Crossroads Pkwy Graham Road 9,383 700 472 C 0.67 472 C 0.67 4%9 1.3% Graham Road Picos Road 7,181 700 361 C 0.52 361 C 0.52 13%30 4.2% Picos Road Orange Avenue 7,181 880 361 C 0.41 361 C 0.41 13%30 3.4% Orange Avenue Angle Road 15,247 920 767 C 0.83 767 C 0.83 21%48 5.2% Angle Road St. Lucie Boulevard 11,202 880 547 C 0.62 547 C 0.62 13%30 3.4% St. Lucie Boulevard Indrio Road 13,787 880 673 C 0.77 673 C 0.77 10%23 2.6% Shinn Road Campebell Road 2,957 1,070 142 B 0.13 142 B 0.13 1%2 0.2% Campebell Road Kings Highway 2,957 1,070 142 B 0.13 142 B 0.13 1%2 0.2% Kings Highway I-95 18,080 2,100 910 C 0.43 910 C 0.43 7%16 0.8% I-95 Jenkins Road 14,693 2,100 717 C 0.34 717 C 0.34 5%11 0.5% Jenkins Road Hartman Road 16,898 2,100 825 C 0.39 825 C 0.39 4%9 0.4% Hartmand Road Angle Road 16,898 2,100 825 C 0.39 825 C 0.39 1%2 0.1% Angle Road 2 25th Street 9,547 1,710 894 B 0.52 858 B 0.50 9%21 1.2% 25th Street 17th Street 13,554 1,630 661 C 0.41 661 C 0.41 5%11 0.7% 17th Street 13th Street 13,554 1,710 661 C 0.39 661 C 0.39 5%11 0.7% 13th Street 10th Street 13,554 750 661 D 0.88 661 D 0.88 2%5 0.6% Picos Road Orange Avenue 814 540 80 C 0.15 58 C 0.11 0%0 0.0% Kings Highway Keen Road 6,087 880 407 C 0.46 447 C 0.51 2%2 0.3% Keen Road 25th Street 6,087 880 407 C 0.46 447 C 0.51 5%6 0.6% 25th Street Seneca Ave 4,414 750 215 C 0.29 215 C 0.29 0%0 0.0% Seneca Ave US 1 4,414 790 215 C 0.27 215 C 0.27 0%0 0.0% Okeechobee Road Hartman Road 22,086 3,020 1,078 C 0.36 1,078 C 0.36 2%2 0.1% Hartman Road 35th Street 22,086 3,020 1,078 C 0.36 1,078 C 0.36 2%2 0.1% 35th Street 13th Street 21,451 3,020 1,047 C 0.35 1,047 C 0.35 6%7 0.2% 13th Street 11th Street 23,517 3,020 1,148 C 0.38 1,148 C 0.38 6%7 0.2% 11th Street Sunrise Boulevard 23,517 3,170 1,148 C 0.36 1,148 C 0.36 6%7 0.2% Sunrise Boulevard Oleander Ave 20,046 3,020 978 C 0.32 978 C 0.32 5%6 0.2% Oleander Ave Colonial Rd 18,476 3,170 902 C 0.28 902 C 0.28 3%3 0.1% Colonial Rd US 1 18,476 3,020 902 C 0.30 902 C 0.3 3%3 0.1% Notes: (1) Obtained from St. Lucie Transporation Planning Organization Traffic Counts and Level of Service Report 2023 (2) Data obtained from FDOT's Florida Traffic Online as the SLTPOTraffic Counts and Level of Service Report 2023 omitted this segment's traffic volumes Angle Road 25th Street 33rd Street Johnston Road % Project SignificanceFrom Roadway AADT PM Peak Hour Directional % Project Distribution Max Directional Peak Hour Project Trips Directional Peak Hour Service Capacity AM Peak Hour Directional Orange Avenue Virginia Ave St Lucie Blvd Campbell Road Kings Highway/Turnpike Feeder Road Page 344 of 456 Indrio Townhomes November 2024 -Horn and Associates, Inc. 9 3.0 DEVELOPMENT TRAFFIC 3.1 TRIP GENERATION Trip generation for the proposed project was calculated per procedures published in the 11th Edition of the Trip Generation Manual. Land use code 215 Single-Family Attached Housing was referenced to determine the appropriate trip rates for the project. Table 6 provides the Daily, AM peak hour, and PM peak hour trip generation summary for the project. Relevant excerpts from the ITE Trip Generation Manual are included in Appendix H. Table 6: Trip Generation Summary Indiro Townhomes Page 345 of 456 18 % 22 % 5% EM E R S O N A V E DR W Y 1 KI N G S H I G H W A Y EM E R S O N A V E N U E 8% 16 % N K I N G S H W Y De l e o n A v e 8% De l e o n A v e 30 % Ro y a l P a l m A v e 26 % 10 % 30 % 20 % 30 % 22 % Page 346 of 456 17 ( 1 2 ) 21 ( 1 5 ) 2 ( 5 ) EM E R S O N A V E DR W Y 1 KI N G S H I G H W A Y EM E R S O N A V E N U E 9 ( 1 9 ) 3 ( 7 ) 7 ( 1 5 ) N K I N G S H W Y 8 ( 6 ) 4 ( 9 ) 29 ( 2 1 ) De l e o n A v e 21 ( 1 5 ) 13 ( 2 8 ) Ro y a l P a l m A v e 11 ( 2 4 ) 29 ( 2 1 ) De l e o n A v e Page 347 of 456 NB/EB SB/WB NB/EB SB/WB NB/EB SB/WB NB/EB SB/WB NB/EB SB/WB NB/EB SB/WB NB/EB SB/WB NB/EB SB/WB NB/EB SB/WB NB/EB SB/WB NB/EB SB/WB NB/EB SB/WB NB/EB SB/WB NB/EB SB/WB 1 1 48 49 17 6 13 8 0 0 26 27 0 0 16 7 0 0 77 78 4 11 0 0 0 0 15 14 4 1 16 7 6 24 7 23 1 1 16 16 6 2 6 4 0 0 0 0 9 9 2 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 16 20 21 6 4 2 19 19 3 1 26 17 0 0 10 4 6 6 23 9 29 10 0 1 10 8 6 20 20 11 8 8 14 41 11 17 0 0 17 6 6 6 23 9 29 10 2 4 5 4 40 41 105 36 79 50 0 0 77 82 1 3 5 7 6 11 70 69 26 77 42 66 0 0 40 37 0 1 34 42 0 0 15 3 7 12 53 54 72 25 60 38 0 0 0 3 29 31 4 7 32 39 63 16 0 0 7 12 45 46 72 25 60 38 0 0 1 3 23 24 0 0 0 0 3 7 8 10 17 57 4 2 19 19 28 9 17 11 0 0 4 2 11 12 0 2 0 0 6 11 NB/EB SB/WB NB/EB SB/WB NB/EB SB/WB NB/EB SB/WB NB/EB SB/WB NB/EB SB/WB NB/EB SB/WB NB/EB SB/WB NB/EB SB/WB NB/EB SB/WB NB/EB SB/WB NB/EB SB/WB NB/EB SB/WB NB/EB SB/WB 3 3 69 67 12 20 17 20 0 0 35 35 0 0 13 16 0 0 112 108 13 8 0 0 0 0 19 20 3 4 13 16 14 64 22 15 1 1 23 22 4 7 9 10 0 0 0 0 12 12 1 2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 0 0 0 0 43 41 21 17 3 5 27 26 2 1 35 41 0 0 6 11 8 8 18 23 21 35 0 2 20 21 15 10 14 27 11 12 14 29 27 22 0 0 11 19 8 8 18 23 21 35 4 3 11 11 58 56 75 127 105 124 0 0 106 104 4 2 14 14 15 8 97 100 94 55 104 88 0 0 50 51 1 1 92 88 0 0 10 7 16 9 77 75 51 87 79 94 0 0 0 2 39 39 8 5 85 82 12 8 0 0 16 9 66 63 51 25 79 94 0 0 3 2 31 31 0 0 0 0 7 5 21 20 24 28 4 5 27 26 20 9 22 27 0 0 3 5 16 15 0 5 0 0 12 8Kings Hwy to Slash Pine Trl 2098 Johnston Rd (25%) 2098 Johnston Rd (25%) Spanish Lakes Blvd to Indrio Rd Indrio Rd to St. Lucie Blvd Koblegard Rd to Johnston Rd Johnston Rd to Emerson Ave Emerson Ave to Seminole Rd Seminole Rd to Kings Hwy Kings Hwy to Slash Pine Trl Segment Russos Road to Indrio Road Indrio Rd to Old Johnston Rd Russos Road to Indrio Road Indrio Road to Driveway Spanish Lakes Blvd to Indrio Rd Indrio Rd to St. Lucie Blvd Johnston Road Emerson Ave Kings Hwy Indrio Road Segment Russos Road to Indrio Road Indrio Rd to Old Johnston Rd Russos Road to Indrio Road Johnston Road Emerson Ave Kings Hwy Indrio Road Roadway Comitted Traffic AM Comitted Traffic PM Indrio Road to Driveway Sabal Palm Grove 4540 N Kings Hwy (25%) Indrio Townhomes (25%) Indrio Townhomes (25%) Koblegard Rd to Johnston Rd Johnston Rd to Emerson Ave Emerson Ave to Seminole Rd Seminole Rd to Kings Hwy NVR Fort Pierce NVR Fort Pierce Pineapple Grove Pineapple Grove Roadway Sabal Palm Grove 4540 N Kings Hwy (25%) Eagle Bend (25%)Buc-ee's Publix at Indrio Indrio Woods Cabo Rio RV Resort Indrio & I-95 Development (25%) Indrio Groves (25%) Bedner Farms (25%) Eagle Bend (25%)Buc-ee's Publix at Indrio Indrio Woods Cabo Rio RV Resort Indrio & I-95 Development (25%) Indrio Groves (25%) Bedner Farms (25%) APPENDIX G Page 348 of 456 Ownership BRINDHAVANAM LLC 4528 Shiloh Mill BLVD Jacksonville, FL 32246-1877 Current Values Just/Market value:$635,655 Assessed value:$4,241 Exemption value:$0 Taxable value:$4,241 Property Identification Site Address:EMERSON AVE Sec/Town/Range:14/34S/39E Parcel ID:1314-323-0002-000-3 Jurisdiction:Saint Lucie County Land Use Code:6000 - GRZNG SLD CP Account #:155782 Map ID:13/14S Zoning:AG-1 Count Legal Description 14 34 39 S 1/2 OF NW 1/4 OF SW 1/4-LESS N 170 FT AND LESS CANAL AND RD RS/W (15.42 AC) Total Areas Finished/Under Air (SF):0 Gross Sketched Area (SF):0 Land Size (acres):15.42 Land Size (SF):671,695 Building Wind Speed Sources/links: Map Occupancy Category I II III & IV Speed 140 150 160 State of Florida, Earthstar Geographics Powered by Esri 9/24/25, 1:23 PM Property Card https://map.paslc.gov/search/#data_s=id%3AdataSource_2-1967cfaa663-layer-5-1967cfaa667-layer-13%3A7521&widget_27=search_status:%7B"sea…1/4 APPENDIX H Page 349 of 456 Ownership BRINDHAVANAM LLC 4528 Shiloh Mill BLVD Jacksonville, FL 32246-1877 Current Values Just/Market value:$731,939 Assessed value:$4,986 Exemption value:$0 Taxable value:$4,986 Property Identification Site Address:SEMINOLE RD Sec/Town/Range:14/34S/39E Parcel ID:1314-313-0000-000-8 Jurisdiction:Saint Lucie County Land Use Code:6000 - GRZNG SLD CP Account #:127792 Map ID:13/14S Zoning:AG-1 Count Legal Description 14 34 39 S 1/2 OF NE 1/4 OF SW 1/4-LESS N 208.71 FT OF E 208.71 FT AND LESS RD AND CANAL RS/W- (18.13 AC) Total Areas Finished/Under Air (SF):0 Gross Sketched Area (SF):0 Land Size (acres):18.13 Land Size (SF):789,742.8 Building Wind Speed Sources/links: Map Occupancy Category I II III & IV Speed 140 150 160 Earthstar Geographics Powered by Esri 9/24/25, 1:24 PM Property Card https://map.paslc.gov/search/#data_s=id%3AdataSource_2-1967cfaa663-layer-5-1967cfaa667-layer-13%3A7515&widget_27=search_status:%7B"sea…1/4Page 350 of 456 Ownership BRINDHAVANAM LLC 4528 Shiloh Mill BLVD Jacksonville, FL 32246-1877 Current Values Property Identification Site Address:EMERSON AVE Sec/Town/Range:14/34S/39E Parcel ID:1314-331-0001-000-1 Jurisdiction:Saint Lucie County Land Use Code:6000 - GRZNG SLD CP Account #:5077 Map ID:13/14S Zoning:AG-1 Count Legal Description 14/23 34 39 FROM SW COR SEC 14 RUN N 89 DEG 30 MIN 19 SEC E ALG S LI OF SEC 48 FT TO E R/W LI EMERSON AV AND POB, TH N 00 DEG 07 MIN 22 SEC E ALG SD E R/W 1311.43 FT TO C/L OF DITCH, TH N 89 DEG 49 MIN 59 SEC E ALG C/L 1218.78 FT, TH S 45 DEG 07 MIN 23 SEC E 46.22 FT, TH S 00 DEG 35 MIN 00 SEC W 1472.61 FT TO S LI OF N 6.18 AC OF NW 1/4 OF NW 1/4 OF SEC 23, TH S 89 DEG 30 MIN 19 SEC W 1239.97 FT TO E R/W EMERSON AV, TH N 00 DEG 10 MIN 00 SEC E 200.88 FT TO POB (43.14 AC) Total Areas Finished/Under Air (SF):0 Gross Sketched Area (SF):0 Land Size (acres):43.14 Land Size (SF):1,879,178.4 Building Wind Speed Sources/links: Map Occupancy Category I II III & IV Speed 140 150 160 Earthstar Geographics Powered by Esri 9/24/25, 1:24 PM Property Card https://map.paslc.gov/search/#data_s=id%3AdataSource_2-1967cfaa663-layer-5-1967cfaa667-layer-13%3A7522&widget_27=search_status:%7B"sea…1/4Page 351 of 456 Ownership BRINDHAVANAM LLC 4528 Shiloh Mill BLVD Jacksonville, FL 32246-1877 Current Values Just/Market value:$966,080 Assessed value:$6,798 Exemption value:$0 Taxable value:$6,798 Property Identification Site Address:SEMINOLE RD Sec/Town/Range:14/34S/39E Parcel ID:1314-342-0001-000-5 Jurisdiction:Saint Lucie County Land Use Code:6000 - GRZNG SLD CP Account #:142347 Map ID:13/14S Zoning:AG-1 Count Legal Description 14/23 34 39 W 1/2 OF SE 1/4 OF SW 1/4 AND N 230 FT OF NW 1/4 OF NE 1/4 OF NW 1/4 (24.72 AC) Total Areas Finished/Under Air (SF):0 Gross Sketched Area (SF):0 Land Size (acres):24.72 Land Size (SF):1,076,803 Building Wind Speed Sources/links: Map Occupancy Category I II III & IV Speed 140 150 160 Earthstar Geographics Powered by Esri 9/24/25, 1:25 PM Property Card https://map.paslc.gov/search/#data_s=id%3AdataSource_2-1967cfaa663-layer-5-1967cfaa667-layer-13%3A7524&widget_27=search_status:%7B"sea…1/4Page 352 of 456 Ownership BRINDHAVANAM LLC 4528 Shiloh Mill BLVD Jacksonville, FL 32246-1877 Current Values Just/Market value:$393,993 Assessed value:$2,181 Exemption value:$0 Taxable value:$2,181 Property Identification Site Address:SEMINOLE RD Sec/Town/Range:23/34S/39E Parcel ID:1323-211-0005-000-8 Jurisdiction:Saint Lucie County Land Use Code:6000 - GRZNG SLD CP Account #:5200 Map ID:13/23N Zoning:AG-1 Count Legal Description 23 34 39 N 3/4 OF N 1/2 OF NE 1/4 OF NW 1/4-LESS N 230 FT AND LESS E 90 FT (7.93 AC) Total Areas Finished/Under Air (SF):0 Gross Sketched Area (SF):0 Land Size (acres):7.93 Land Size (SF):345,431 Building Wind Speed Sources/links: Map Occupancy Category I II III & IV Speed 140 150 160 Earthstar Geographics Powered by Esri 9/24/25, 1:25 PM Property Card https://map.paslc.gov/search/#data_s=id%3AdataSource_2-1967cfaa663-layer-5-1967cfaa667-layer-13%3A7904&widget_27=search_status:%7B"sea…1/4Page 353 of 456 160004 Page 36 CONCLUSION MacKenzie Engineering and Planning, Inc. (MEP) was retained by Buc-ee’s to perform a traffic analysis on a proposed travel center in St. Lucie County, FL. The proposed development is situated on the southeast corner of Indrio & I-95 in St. Lucie County, FL 32968 (Parcel ID’s: 1316-321-0002-000- 3). The proposed development will include approximately 120 vehicle fueling positions and 75,000 SF of convenience market. A buildout year of 2026 was analyzed for the proposed project. The site proposes three outparcels along with Buc-ee's. The following uses were applied to the outparcels in order to provide a conservative analysis at buildout: 1. 120 Rooms of Hotel 2. 5,000 SF of Drive-in Bank 3. 10,000 SF of High-Turnover (Sit-Down) Restaurant The total proposed development will generate the following net new external trips (relative to the adjacent road network): • 22,359 daily, 1,180 AM peak hour (610 in/570 out), and 1,558 PM peak hour (772 in/786 out). Buc-ee’s is expected to divert the following trips from I-95, which are considered within the net new external trips stated above: • 17,528 daily, 830 AM peak hour (423 in/407 out), and 1,171 PM peak hour (574 in/597 out) The total proposed development will generate the following cumulative driveway trips: • 22,941 daily, 1,235 AM peak hour (640 in/595 out), and 1,625 PM peak hour (810 in/815 out) trips. The project will construct the following improvements: • Indrio Road & I-95 SB Off-Ramp 1. Adjust signal timing • Indrio Road & I-95 NB Off-Ramp 2. Construct the 2nd northbound right-turn lane and urbanize the northbound right-turn off ramp 3. Adjust signal timing 4. Coordinate Ramp Signals Page 354 of 456 160004 Page 37 • Indrio Road & Koblegard Road 5. Construct two (2) northbound left-turn lanes 6. Construct one northbound right-turn lane 7. Construct one northbound through lane 8. Construct one eastbound right-turn lane 9. Extend the westbound left-turn lane to 615 feet (including 50 feet taper) 10. Adjust signal timing • Indrio Road & Driveway 1 11. An eastbound right-turn lane The following needed improvements are not the responsibility of the applicant and are recommended to be the responsibility of other unapproved development projects: • Koblegard Road & Indrio Road 1. Add the 2nd southbound left-turn lane 2. Restripe the existing southbound through/left-turn lane to a through lane 3. Extend the eastbound left-turn lanes to at least 625 feet • Kings Highway & Indrio Road 4. Add the 2nd eastbound left-turn lane 5. Adjust signal timing Indrio Road from Emerson Avenue to Kings Highway is projected to fail due to background traffic growth. In accordance with Chapter 163.3180 F.S., the street maintaining agency has the responsibility to improve Indrio Road from Emerson Avenue to Kings Highway from 2-lane to 4-lanes or identify and construct an alternative parallel facility as recommended within the TVC plan. Page 355 of 456 Page 356 of 456 Page 357 of 456 Page 358 of 456 Page 359 of 456 1 ST LUCIE COUNTY DEVELOPMENT REVIEW COMMENTS Discipline: Traffic Engineering Reviewed by: Salman Rathore, PE Review Date: June 8th, 2026 Phone: (404) 542-4948 Fax: (954) 921-8807 Project Name: The Club at Indrio Creek Traffic Impact Study – 3rd Review CGA Project Number: 204113 / 195793 Comments based on review of response to comments dated April 17th, 2026 and revised Traffic Impact Study prepared by MacKenzie Engineering & Planning, Inc. dated December 10th, 2025. No comments X Comments as follows or attached 1. Existing Counts – The TMCs used in the study are more than a year old (2024). The TIS must be updated based on recently obtained counts. MacKenzie Engineering & Planning, Inc. response to comments (dated December 12th, 2025) - The request to use newer counts is not part of the approved methodology. In addition, the 2024 counts are the peak season 2024 counts which are 1 year old and acceptable. CGA Response (dated February 26th, 2026) – Satisfied. 2. Figure 3 / Trip Distribution – No project trips are heading in the southbound direction on Emerson Road and Seminole Road which doesn’t make sense. Clarify. MacKenzie Engineering & Planning, Inc. response to comments (dated December 12th, 2025) - The study used the traffic assignment from the approved traffic methodology. In addition, Emerson Avenue does not exist south of the project and Seminole Road is a local street. The project’s only connection to Seminole Road is an emergency access. CGA Response (dated February 26th, 2026) – Satisfied. 3. Committed Improvements / Pg. 7 – Include excerpts from the relevant sources verifying the committed improvements for FDOT projects and private developments. Page 360 of 456 2 MacKenzie Engineering & Planning, Inc. response to comments (dated December 12th, 2025) - See Appendix I in the revised Study. CGA Response (dated February 26th, 2026) – Satisfied. 4. Tables 4A / 4B - The number of lanes and roadway capacity for Indrio Road and its segment do not appear to be correct. Check. MacKenzie Engineering & Planning, Inc. response to comments (dated December 12th, 2025) - Acknowledged. Please see the revised TIA study, under Post Development Analysis. CGA Response (dated February 26th, 2026) – Satisfied. 5. Intersection Analysis / pg. 14 – The results are not presented in a standard format. For all study intersections, include LOS, v/c ratio etc. for all approaches including overall LOS result. This should be presented for existing, future background and future build scenarios. MacKenzie Engineering & Planning, Inc. response to comments (dated December 12th, 2025) - Acknowledged. Please see the revised TIA study, under Intersection Analysis Tables 7A and 7B. CGA Response (dated February 26th, 2026) – Satisfied. 6. Driveway 1 Analysis – 182 vehicles in the peak hour are projected to turn left into driveway 1. Include relevant references justifying a left turn lane of 235’. MacKenzie Engineering & Planning, Inc. response to comments (dated December 12th, 2025) – Turn lane length = Queue plus deceleration Page 361 of 456 3 Queue from analysis = 0 feet; Queue recommended for design = 50 feet Deceleration based on 35 MPH design speed = 145 feet (Table 3-33 Greenbook); deceleration distance of 185 feet recommended Recommended deceleration 235 is greater than the minimum required of 145 feet CGA Response (dated February 26th, 2026) – Satisfied. Additional comment (dated February 26th, 2026) 7. Improvements / Pg 23 - Where are the improvements shown below mentioned in the analysis of the report? Also, which project development is responsible for these improvements? MacKenzie Engineering & Planning, Inc. response to comments (dated April 17th, 2026) – Discussions of the Indrio Road & Koblegard Road improvements are located on Page 15. Discussions of Indrio Road & Kings Highway improvements are located on Page 16. Buc-ee's will extend the westbound left-turn lane at Indrio Road & Koblegard Road. It is anticipated that Bednar Farms, Indrio Groves, or Bednar Farms Commercial will extend the eastbound left-turn, southbound left-turn, and westbound right-turn lanes. Indrio Groves proposed to extend the eastbound left-turn lane at Kings Highway & Indrio Road. CGA Response (dated June 8th, 2026) – Satisfied. Date: June 8th, 2026 Salman Rathore, PE Project Manager, Transportation & Mobility Department Calvin Giordano & Associates Page 362 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 1 of 62 3.01.03. Zoning Districts. A. AG-1 AGRICULTURAL - 1. 1. Purpose. The purpose of this district is to provide and protect an environment suitable for productive commercial agriculture, together with such other uses as may be necessary to and compatible with productive agricultural surroundings. Residential densities are restricted to a maximum of one (1) dwelling unit per gross acre. The number in "( )" following each identified use corresponds to the SIC Code reference described in Section 3.01.02(B). The number 999 applies to a use not defined under the SIC Code but may be further defined in Section 2.00.00 of this Code. 2. Permitted Uses. a. Agricultural production - crops. (01) b. Agricultural production - livestock and animal specialties. (02) c. Agricultural services. (07) d. Family day care homes. (999) e. Family residential homes provided that such homes shall not be located within a radius of one thousand (1,000) feet of another existing such family residential home and provided that the sponsoring agency or Department of Health and Rehabilitative Services (HRS) notifies the Board of County Commissioners at the time of home occupancy that the home is licensed by HRS. (999) f. Fishing, hunting and trapping. (09) g. Forestry. (08) h. Kennels. (0752) i. Research facilities, non-commercial. (8733) j. Riding stables. (7999) k. Single-family detached dwellings. (999) l. Solar generation station, subject to the requirements of Section 7.10.28. (999) 3. Lot Size Requirements. Lot size requirements shall be in accordance with Table 7-10 in Section 7.04.00. 4. Dimensional Regulations. Dimensional requirements shall be in accordance with Table 7-10 in Section 7.04.00. 5. Off-Street Parking and Loading Requirements. Off-street parking and loading requirements are subject to Section 7.06.00. 6. Landscaping Requirements. Landscaping requirements are subject to Section 7.09.00. 7. Conditional Uses. a. Agricultural labor housing. (999) b. Aircraft storage and equipment maintenance. (4581) c. Airports and flying, landing, and takeoff fields. (4581) d. Family residential homes located within a radius of one thousand (1,000) feet of another such family residential home. (999) e. Farm products warehousing and storage. (4221/4222) Page 363 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 2 of 62 f. Farmers' markets - subject to the requirements of Section 7.10.37. (999) g. Gasoline service stations. (5541) h. Industrial wastewater disposal. (999) i. Manufacturing: (1) Agricultural chemicals. (287) (2) Food and kindred products. (20) (3) Lumber and wood products, except furniture. (24) j. Mining and quarrying of nonmetallic minerals, except fuels. (14) k. Retail trade: (1) Farm equipment and related accessories. (999) (2) Apparel and accessory stores. (56) l. Sewage disposal subject to the requirements of Section 7.10.13. (999) m. Telecommunication towers - subject to the standards of Section 7.10.23. (999) n. Camps - sporting and recreational. (7032) 8. Accessory Uses. Accessory uses are subject to the requirements of Section 8.00.00, and include the following: a. Mobile homes subject to the requirements of Section 7.10.05. b. Retail trade and wholesale trade - subordinate to the primary authorized use or activity. c. Guest house subject to the requirements of Section 7.10.04. (999) d. Solar energy system subject to the requirements of Section 7.10.28. (999) e. Cargo containers subject to the requirements of Section 7.10.35. EE. PTV (PLANNED TOWN OR VILLAGE). 1. Purpose. The Planned Town or Village (PTV) district provides a specialized zoning district to expedite county approval of a Town or Village on land designated TVC on the Future Land Use Map of the St. Lucie County Comprehensive Plan. 2. Standards and Requirements. Standards and requirements for Planned Town or Villages shall be as follows: a. Design Concepts for Towns and Villages. Towns and Villages use the principles of traditional neighborhood design to create a sustainable growth pattern characterized by a mix of uses, building types, and income levels on a pedestrian-friendly block and street network. Each Town and Village also preserves a significant amount of Countryside that includes viable agriculture, public open space, and environmental preservation and restoration. Design concepts for Towns and Villages are described further in the TVC Element of the St. Lucie County Comprehensive Plan, which contains specific settlement principles which must be followed in the design of new neighborhoods. b. Overall Requirements for Towns and Villages. Page 364 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 3 of 62 (1) Each Town consists of two (2) or more neighborhoods and adjoining Countryside and must meet the following requirements: SIZE: Minimum parcel size for a Town outside USB: 625 acres Minimum parcel size for a Town inside USB: 225 acres Maximum parcel size: n/a OPEN SPACE AND COUNTRYSIDE: Open Space and Countryside required outside USB: 60% (50% Countryside min.) Open Space and Countryside required inside USB: 40% (40% Countryside min.) DENSITY REQUIRED IN NET DEVELOPABLE AREA: Minimum average density required if inside USB: 6 DU/acre Minimum average density required if outside USB: 5 DU/acre (2) Each Village consists of one (1) neighborhood and adjoining Countryside and must meet the following requirements: SIZE: Minimum parcel size for a Village outside USB: 500 acres Minimum parcel size for a Village inside USB: 110 acres Maximum parcel size: 624 acres OPEN SPACE AND COUNTRYSIDE: Open Space and Countryside required outside USB: 75% (65% Countryside min.) Open Space and Countryside required inside USB: 40% (40% Countryside min.) DENSITY REQUIRED IN NET DEVELOPABLE AREA: Minimum average density required: 5 DU/acre (3) Regional roadways are thoroughfares provided as links of the Future Street Network (Figure 3-15 of the TVC Element). The right-of-way of a regional roadway located within a neighborhood of a Town or Village is counted as part of the Net Developable Area and is included in the minimum average density requirement. The right-of-way of a regional roadway located outside of a neighborhood of a Town or Village is considered part of the Net Developable Area, but is not included in the calculation of the minimum average density requirement. Regional roadways are not counted toward the required amount of Open Space or Countryside. (4) For details on computing the minimum Open Space and Countryside percentages, see Section 3.01.03.EE.2.o. Civic Building Lots, including those used for public schools, that are located within the net developable area of a Town or Village are not included in the calculation of the required minimum average density. c. Transect Zones Generally. (1) Transect zones. All land within each PTV must be allocated to one (1) of the six (6) transect zones described below. Each transect zone controls allowable street types and lot types, Page 365 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 4 of 62 which then control the placement and intensity of buildings and other uses of land. Each neighborhood may be comprised of the following Neighborhood transect zones: i. Core ii. Center iii. General iv. Edge The Countryside surrounding neighborhoods must be allocated to the following Countryside transect zones: v. Fringe vi. Rural The general standards for each transect zone are described in Section 3.01.03.EE.2.d. (2) Transect assignment concepts. Each PTV application must include a regulating plan that clearly identifies the proposed allocation of transect zones within the entire Town or Village and adjoining Countryside on the same parcel (see Section 3.01.03.EE.3). The allocation of transect zones is intended to ensure variety and mixture of use and lot types in neighborhoods and to delineate the Countryside that will be permanently protected after development of the Town or Village. The following general guidelines shall be followed when proposing transect zones: i. Generally, a neighborhood has more intensity (Core or Center) in the center less intensity (General or Edge) at the extremes. ii. When the neighborhood is adjacent to a busy street or highway, or adjacent to an established urban area, the transect zones with greater intensity (Core or Center) may adjoin that highway or urban area. iii. Similar uses should face across streets; changes in transect zones should generally occur along rear or side lot lines rather than along streets. iv. The character of the neighborhood is determined by the transect zones of which it is comprised; neighborhoods vary in character internally. Some neighborhoods may be more intense and have a higher percentage of Core and Center while others may have a higher percentage of General and Edge. However, each neighborhood must meet the percentage requirements set forth below. v. When a new neighborhood will adjoin an existing development, existing agriculture, or an existing or approved neighborhood, the new neighborhood should establish similar transect conditions (such as Core aligning with Core or Center, and Rural aligning with Rural) to ensure compatibility. Transect juxtapositions may be approved by St. Lucie County where natural conditions warrant them or where alignment of similar transect conditions would be inappropriate. (3) Transect assignment percentages. Each proposed regulating plan must allocate transect zones within the following percentage ranges. An applicant may propose minor variations on these percentages during the PTV rezoning process based upon site-specific constraints and compliance with the intent of the TVC Element and this Code. The Board of County Page 366 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 5 of 62 Commissioners shall decide whether to accept, modify, or reject such variations during the approval process. i. Core: for Villages, no minimum; for Towns, one percent (1%) of each neighborhood minimum; ten percent (10%) maximum in any neighborhood. ii. Center: Five percent (5%) of each neighborhood minimum; thirty percent (30%) maximum. iii. General: Thirty percent (30%) of each neighborhood minimum; sixty percent (60%) maximum. iv. Edge: Ten percent (10%) of each neighborhood minimum; forty-five percent (45%) maximum. v. Fringe: no minimum; maximum thirty percent (30%) of Countryside. vi. Rural: see Section 3.01.03.EE.2.b d. Standards for each Transect Zone. The general standards for each transect zone are described below. Page 367 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 6 of 62 (1) "Core" Transect Zone. Purpose: Development is most intense in the Core, the most urban of the transect zones. Buildings are normally attached and built along the front property line, creating a continuous street facade to increase walk -ability. Commercial and civic uses are anticipated in the Core; a mix of apartments and live/work buildings constitute the residential component. Core zones must be within walking distance of surrounding residential areas. Permitted Lot Types in the Core transect zone (refer to Section 3.01.03.EE.2.e): • Mixed-Use Building Lot • Retail Building Lot Page 368 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 7 of 62 • Apartment Building Lot • Live/Work Building Lot • Civic Building Lot Building Form and Placement on Lots for the Center transect zone: refer to Section 3.01.03.EE.2.f. Development Standards for the Core transect zone: refer to Section 3.01.03.EE.2.g. Permitted Uses for the Core transect zone: permitted uses are determined by lot type — refer to Section 3.01.03.EE.2.h. Allowable Street Types in the Core transect zone (refer to Section 3.01.03.EE.2.i): • Main Street • Boulevard • Avenue • Alley • Trail Page 369 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 8 of 62 (2) "Center" Transect Zone. Purpose: A wide range of uses is expected and encouraged in the Center, which should be compact and contain both attached and detached buildings. Multi-story buildings accommodate a mix of uses such as apartments or offices over shops. Lofts (flexible spaces that can be used for either living or working space) and buildings designed for changing uses over time are also appropriate for the Center. Center zones must be within walking distance of surrounding residential areas. Permitted Lot Types in the Center transect zone (refer to Section 3.01.03.EE.2.e): • Mixed-Use Building Lot • Retail Building Lot Page 370 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 9 of 62 • Apartment Building Lot • Live/Work Building Lot • Apartment House Lot • Rowhouse Lot • Cottage House Lot • Sideyard House Lot • Civic Building Lot Building Form and Placement on Lots for the Center transect zone: refer to Section 3.01.03.EE.2.f. Development Standards for the Center transect zone: refer to Section 3.01.03.EE.2.g. Permitted Uses for the Center transect zone: permitted uses are determined by lot type — refer to Section 3.01.03.EE.2.h. Allowable Street Types in the Center transect zone (refer to Section 3.01.03.EE.2.i): • Main Street • Boulevard • Avenue • East/West Street • North/South Street • Alley • Lane • Trail Page 371 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 10 of 62 (3) "General" Transect Zone. Purpose: The General zone is the largest area of most neighborhoods. It is residential in character with a mix of housing types including single-family attached and detached homes and multi-family units. Homes located in the General zone are normally set back from the front property line to allow a front yard with a porch or stoop; lots often have private rear yards. Permitted Lot Types in the General transect zone (refer to Section 3.01.03.EE.2.e): • Apartment Building Lot • Live/Work Building Lot • Apartment House Lot Page 372 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 11 of 62 • Rowhouse Lot • Cottage House Lot • Sideyard House Lot • House Lot • Civic Building Lot Building Form and Placement on Lots for the General transect zone: refer to Section 3.01.03.EE.2.f. Development Standards for the General transect zone: refer to Section 3.01.03.EE.2.g. Permitted Uses for the General transect zone: permitted uses are determined by lot type — refer to Section 3.01.03.EE.2.h. Allowable Street Types in the General transect zone (refer to Section 3.01.03.EE.2.i): • Boulevard • Avenue • East/West Street • North/South Street • Lane • Trail Streetscape Standards for the General transect zone: refer to Section 3.01.03.EE.2.j. Page 373 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 12 of 62 (4) "Edge" Transect Zone. Purpose: The Edge zone is single-family residential in character with a lower density of homes than other parts of the neighborhood. Edge zones are bounded by the beginnings of rural, natural, or open-space features such as pasture, groves, forest, lake, meadow, or golf course. These features provide a physical change that defines the neighborhood. Permitted Lot Types in the Edge transect zone (refer to Section 3.01.03.EE.2.e): • House Lot • Estate Lot • Civic Building Lot Page 374 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 13 of 62 Building Form and Placement on Lots for the Edge transect zone: refer to Section 3.01.03.EE.2.f. Development Standards for the Edge transect zone: refer to Section 3.01.03.EE.2.g. Permitted Uses for the Edge transect zone: permitted uses are determined by lot type — refer to Section 3.01.03.EE.2.h. Allowable Street Types in the Edge transect zone (refer to Section 3.01.03.EE.2.i): • East/West Street • North/South Street • Edge Drive • Parkway • Lane • Trail Page 375 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 14 of 62 (5) "Fringe" Transect Zone. Purpose: The Fringe zone is the first layer of the Countryside that provides a harmonious transition between neighborhoods and the Rural transect zone. The resulting landscape is typically more manicured and includes uses that are compatible with adjoining neighborhoods such as open spaces, recreational uses, and limited agricultural uses. Permitted Lot Types in the Fringe transect zone (refer to Section 3.01.03.EE.2.e): • Estate Lot (limited, see footnote to Table 3-2) • Civic Building Lot • Countryside Tract Page 376 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 15 of 62 Building Form and Placement on Lots for the Fringe transect zone: refer to Section 3.01.03.EE.2.f. Development Standards for the Fringe transect zone: refer to Section 3.01.03.EE.2.g. Permitted Uses for the Fringe transect zone: refer to Section 3.01.03.EE.2.o. Allowable Street Types in the Fringe transect zone (refer to Section 3.01.03.EE.2.i): • Boulevard • Parkway • Trail (6) "Rural" Transect Zone. Page 377 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 16 of 62 Purpose: The Rural zone is the second layer of the Countryside that does not adjoin neighborhoods. Land uses in the Rural zone encompass the full range of permitted agricultural, recreational, and open space uses. Permitted Lot Types in the Rural transect zone (refer to Section 3.01.03.EE.2.e): • Countryside Tract Building Form and Placement on Lots for the Rural transect zone: refer to Section 3.01.03.EE.2.f. Development Standards for the Rural transect zone: refer to Section 3.01.03.EE.2.g. Permitted Uses for the Rural transect zone: refer to Section 3.01.03.EE.2.o. Allowable Street Types in the Rural transect zone (refer to Section 3.01.03.EE.2.i): • Boulevard • Parkway • Trail Streetscape Standards for the Rural transect zone: refer to Section 3.01.03.EE.2.j. e. Lot types. (1) Each neighborhood must contain a mixture of lot types to provide a variety of uses and diverse housing options within the neighborhood. Differing lot types may be placed back- to-back on a single block to provide harmonious transitions between lot types. Lot types should be selected to provide buildings of like scale and massing on opposite sides of streets. Each neighborhood must contain at least one (1) Mixed-Use or Retail Building Lot. Each neighborhood must contain at least three (3) Civic Building Lots; one (1) civic building must be constructed within two (2) years after development commences. (2) The following lot types may be assigned within the corresponding transect zones as shown in the following matrix. An applicant may propose additional lot types during the PTV rezoning process provided the lot types comply with the intent of the TVC Element; the Board of County Commissioners shall decide whether to accept, modify, or reject such additional lot types during the approval process based on consistency with the goals, objectives and policies of the TVC Element and the applicable site plan approval standards in Chapter XI of this Code. Transect zones Countryside Neighborhoods Lot Types Ru ra l Fr i ng e Ed ge Ge ne ra l Ce nt er Co re Mixed-Use Building Lot X X Retail Building Lot X X Apartment Building Lot X X X Live/Work Building Lot X X X Apartment House Lot X X Rowhouse Lot X X Cottage House Lot X X Sideyard House Lot X X Page 378 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 17 of 62 House Lot X X Estate Lot* X* X Civic Building Lot X X X X X Countryside Tract X X * Estate Lots in Fringe transect zones are limited to a maximum of 5% of the land area for Open Space and Countryside components; the allowance for these lots must be acquired by TDR Credits transferred from an off-site eligible sending site (see Section 4.04.05). f. Building Form and Placement on Lots. The primary entrance of every building must directly face a street, a square, a park, a plaza, or a green. The proper building placement is illustrated below for each lot type, along with additional regulations plus illustrations of some of the lot size and dimensional requirements from Table 3-1. Page 379 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 18 of 62 Page 380 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 19 of 62 Page 381 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 20 of 62 Page 382 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 21 of 62 Page 383 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 22 of 62 Page 384 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 23 of 62 Page 385 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 24 of 62 Page 386 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 25 of 62 Page 387 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 26 of 62 Page 388 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 27 of 62 g. Development Standards for Lots. (1) Table 3-1 provides dimensional requirements that apply to all lots of each designated type. These requirements replace those found in Section 7.04.01. (2) If additional lot types are proposed by an applicant, comparable dimensional requirements must also be proposed. An applicant may also propose changes to the dimensional requirements in Table 3-1 for a particular neighborhood. All changes must comply with the intent of the TVC Element. The Board of County Commissioners shall decide whether to accept, modify, or reject such additional or modified dimensional requirements during the approval process based on consistency with the goals, objectives and policies of the TVC Element and the applicable site plan approval standards in Chapter XI of this Code. (3) Each Live/Work, Rowhouse, Cottage, Sideyard, House, and Estate Lot is permitted one (1) main structure and one (1) accessory dwelling. Accessory dwellings are not counted for Page 389 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 28 of 62 density purposes, for instance for meeting the minimum density requirements of Section 3.01.03.EE.2.b. Accessory dwellings, where permitted: i. May not exceed the size limitations in Table 3-1; ii. Must maintain at least a three-foot side yard except on Rowhouse Lots; and iii. Must be separated at least ten (10) feet from the main structure. (4) Building frontage is the percentage of the total width of a lot which is required to be building wall, measured where the front yard ends and the front of the building begins. For this purpose only, the width of a porte cochere may be counted as building wall even though it has no front or rear wall. (5) Front porches and balconies may extend up to ten (10) feet into front yards provided that walls, screened areas, or railings in the front yard extend no higher than forty-two (42) inches above the floor of the porch or balcony. Front porches and balconies may not extend into the right-of-way. Stoops may extend into front yards provided that walls, screened areas, or railings in the front yard extend no higher than forty-two (42) inches above the floor of the stoop. Stoops may extend into the right-of-way to the extent specifically provided by the Board of County Commissioners during the approval process. (6) Each building must have separate walls to support all loads independently of any walls located on an adjacent lot. Buildings with side-facing windows must provide necessary light and air shafts within their own lot without relying on the side yard of an adjacent lot. (7) Each building must have an entrance facing a street or public open space. Page 390 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 29 of 62 TABLE 3-1 LOT SIZE AND DIMENSIONAL REQUIREMENTS Yard Lot Type Lot Size (min/max in sf) Lot Width (min/max) Building Frontage (min/max) Lot Coverage by Bldgs. (max) Front1 (min/max) Rear2 (min) Side (min) Height3 (min/max in stories; max in feet) First Story Elevation (min) Accessory Dwelling4 (max bldg footprint in sf) Mixed-Use Building Lot 2,400/no max 24/no max 80%/100% 80% 0/5 15 0 2/4; 56' n/a not permitted Retail Building Lot 2,400/7,2007 24/607 80%/100% 80% 0/5 15 0 1/4; 50' n/a not permitted Apartment Building Lot 2,400/no max 24/no max 80%/100% 80% 0/10 15 0 2/4; 50' 30"6 not permitted Live/Work Building Lot 1,800/7,200 16/60 80%/100% 80% 0/10 15 0 2/3; 45' n/a 625 Apartment House Lot 4,800/18,000 48/120 70%/90% 80% 5/10 15 0 1/4; 50' 30"6 not permitted Rowhouse Lot 1,800/3,840 16/32 90%/100% 80% 0/10 15 0 2/3; 35' 30" 625 Cottage House Lot 2,400/4,800 24/40 70%/90% 60% 5/25 10 2 1/2; 35' 30" 800 Sideyard House Lot 3,000/6,000 30/60 60%/90% 50% 5/10 10 0/105 1/3; 35' 30" 800 House Lot 4,000/8,400 40/70 60%/80% 50% 5/25 10 5 1/3; 35' 30" 800 Estate Lot 7,200/no max 60/no max n/a 30% 20/50 20 10 1/3; 35' 30" 1000 Civic Building Lot 5,000/no max 50/no max n/a 80% n/a 15 0 1/4; 50' n/a 1250 Page 391 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 30 of 62 Countryside Tract 43,560/no max 200/no max n/a 15% 50/n/a 50 50 1/2; 35' n/a not permitted  1 Corner lots must meet front yard requirements on both streets.  2 Minimum rear yards in this column apply to principal buildings. Buildings for all accessory uses (including garages and accessory dwellings) must maintain a 5-foot minimum rear yard, except when the rear yard adjoins an alley (see Section 3.01.03.EE.2); no separation is required from an alley. Fences are regulated by Section 8.00.04.  3 See definition of "story" for further details on height measurements. The building spacing formula in Section 7.04.03 does not apply in PTV districts.  4 See additional requirements in Section 3.01.03.EE.2.g(3).  5 See Section 3.01.03.EE.2.f(8) for further details.  6 Non-elevator apartments three stories in height or less may be built at grade and shall provide a minimum front yard of 5 feet.  7 No maximum building size or width applies to Retail Building Lots proposed on property with existing Commercial, General (CG) zoning as of August 28, 2009. Page 392 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 31 of 62 (8) Each building on a Mixed-Use Building Lot is required to have an awning, balcony, colonnade, or arcade facing the street. The same requirement applies to Retail Building Lots except that a porch may be substituted. Buildings on Live/Work Building Lots are encouraged but not required to have one (1) of these features. Any of these features may extend into the front yard. Extensions of awnings, balconies, colonnades, or arcades over public sidewalks require approval of the County Attorney who may require the property owner to enter into a right-of-way agreement establishing the property owner's sole responsibility for repairing any damage that may result from public maintenance or improvements. When providing a required awning, balcony, colonnade, arcade, or porch, the following design requirements apply: i. Awnings over first-floor doors or windows must have a depth of at least six (6) feet. Back-lit, high-gloss, or plasticized fabrics are prohibited. ii. Balconies must have a depth of at least five (5) feet and a clear height below of at least ten (10) feet from the sidewalk. Balconies may have roofs but must be open and not air-conditioned. iii. Colonnades and arcades must have a clear width from column to building face of at least eight (8) feet and a clear height of at least ten (10) feet above the sidewalk. iv. Porches must be at least eight (8) feet deep and sixteen (16) feet wide. Porches typically have roofs but must be open and not air-conditioned. (9) Minimum and maximum depths of front yards are shown Table 3-1. For Mixed-Use Building Lots and Retail Building Lots, a portion of the building frontage may be set back up to an additional twenty (20) feet beyond the maximum front yard depth if this space is constructed as a courtyard or entryway that is open to the sidewalk. This portion may be up to forty percent (40%) of the actual building frontage and may not be used for parking. (10) On all Mixed-Use Building Lots and Retail Building Lots, building walls that face streets are required to have between fifteen percent (15%) and seventy-five percent (75%) of their area in transparent windows. In addition, retail stores must comply with the following: i. The ground floor must have transparent storefront windows covering no less than seventy-five percent (75%) of the wall area in order to provide clear views of merchandise in stores and to provide natural surveillance of exterior street spaces. ii. Storefronts must remain unshuttered at night to provide views of display spaces, and are encouraged to remain lit from within until 10:00 p.m. to provide security to pedestrians. iii. Doors allowing public access to streets must be provided at intervals of at least seventy-five (75) feet to maximize street activity, to provide pedestrians with frequent opportunities to enter and exit buildings, and to minimize any expanses of Inactive wall. To be considered transparent, window and door glass, whether integrally tinted or with applied film, must transmit at least fifty percent (50%) of visible daylight. These requirements do not apply to walls that face alleys or lanes. h. Permitted Uses. Table 3-2 identifies the permitted, conditional and accessory uses for each lot type. Where the upper row of Table 3-2 indicates an entire zoning district, an "S" in the column below indicates that a particular lot type is also allowed to have the same permitted, conditional, Page 393 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 32 of 62 and accessory uses that are allowable to any parcel located in that zoning district, in addition to all uses specifically indicated for that lot type in other columns of Table 3-2. Page 394 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 33 of 62 Table 3-2 Permitted Land Uses Lot Type Si n gl e -fa mi ly de ta ch ed d we ll i n gs Tw o- fa mi ly d we ll i n gs M ul t ip l e- fa mi ly d we ll i n gs (3 or m or e un it s ) Co m m un it y Re si d en ti a l Ho m es Fa mi ly Da y Ca re Ho m es Fa mi ly Re si d en ti a l Ho m es [b ey on d 1,00 0' ] Fa mi ly Re si d en ti a l Ho m es [w it h in 1,00 0' ] Be d an d Br ea kf as t Re si d en ce s Re si d en ti a l Ac ce ss or y Us es (s u bj ec t to th e re qu ir e m en ts of Se ct i on 8.00 .0 0) Ci v ic Us es (s e e Se ct i on 4.04 .0 6) Co un tr y si d e Us es (s e e Se ct i on 3.01 .0 3. EE .2 . o) Co m m er ci a l, Ne ig hb or ho od (C N) Co m m er ci a l, Of fi c e (C O) Co m m er ci a l, Ge ne ra l (C G) In du st r ia l Li g ht (I L ) In s ti t ut i on al (I ) Re li g i ou s Fa ci l i ti e s (R F) Mixed-Use Building Lot1, 3 - P* P* P* P* P* P* P* P* P - S S - - S S Retail Building Lot3 - - P P P P P P P P - S S - - S S Apartment Building Lot - - P P P P P P P - - - - - - - - Live/Work Building Lot - P P P P P P P P P - S S - - S S Apartment House Lot - - P P P P c c P - - - - - - - - Rowhouse Lot - P P P P P c c P - - - - - - - - Cottage House Lot P - - - P P c - P - - - - - - - - Sideyard House Lot P - - - P P c - P - - - - - - - - House Lot P - - - P P c - P - - - - - - - - Estate Lot2 P - - c P P c c P - - - - - - - - Civic Building Lot - - - P P P P - P P - - - - - S S Countryside Tract - - - - - - - - - P P - - - - - - NOTES: P = permitted use C = conditional use - = uses are not permitted S = same uses as allowable for any parcel in listed zoning district (in addition to all uses specifically indicated in other columns) 1 Residential uses in Mixed-Use Building Lots may not be placed in the first story. 2 Estate Lots in Fringe transect zones are limited to a maximum of 5% of the land area for Open Space and Countryside components; the allowance for these lots must be acquired by TDR Credits transferred from an off-site eligible sending site (see Section 4.04.05). 3 For properties with exisiting Commercial, General (CG) zoning as of August 28, 2009, both Mixed-Use and Retail Building Lots are permitted the same uses as permitted by such existing zoning. Page 395 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 34 of 62 i. Allowable Street Types by Transect Zone. The following street types are be permitted by right in the transect zones shown. These streets must comply with the streetscape standards in Section 3.01.03.EE.2.j and the street cross-sections in Section 3.01.03.EE.2.l. An applicant may propose additional street types or modified cross-sections and streetscape standards during the PTV rezoning process provided the street types and modified standards comply with the intent of the TVC Element; the Board of County Commissioners shall decide whether to accept, modify, or reject such proposals during the approval process based on consistency with the goals, objectives and policies of the TVC Element and the applicable site plan approval standards in Chapter XI of this Code. Transect zones Countryside Neighborhoods Lot Types Ru ra l Fr i ng e Ed ge Ge ne ra l Ce nt er Co re Main Street X X Boulevard X X X X X X Avenue X X X East/West Street X X X North/South Street X X X Edge Drive X Parkway X X X Rural Road X X Alley X X X Lane X X X X X Trail X X X X X X j. Streetscape Standards by Transect Zone. The following standards apply to all street types as they pass through the indicated transect zone: Transect Zones Countryside Neighborhoods Streetscape Standards Ru r a l Fr i n g e Ed g e Ge n e ra l Ce n t e r Co r e Street edge: Type open swale open swale open swale or raised curb raised curb raised curb raised curb Corner radius1 15' to 30' 15' to 30' 10' to 25' 10' to 20' 10' to 15' 10' to 15' Corner radius2 n/a n/a 5' max. 5' max. 5' max. 5' max. Planting strip: Type swale swale continuous planting strip continuous planting strip planting strip or tree well planting strip or tree well Page 396 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 35 of 62 Width 8' min. 8' min. 8' min. 6' to 12' 4' to 8' 3' to 8' Tree spacing3 clustered or regular clustered or regular regular regular regular or opportunistic regular or opportunistic Tree diversity multiple species allowed multiple species allowed alternating species allowed single species per block single species per block single species per block Walk Type trail (optional) trail (optional) sidewalk (optional) sidewalks required sidewalks required sidewalks required Width 5' min. 5' min. 5' min. 6' min. 8' min.; 12' min w/tree wells 8' min.; 12' min w/tree wells Rear alley/lane: Alley n/a n/a n/a Lane optional optional desirable desirable; (also see 3.01.03.EE.2.k(2)) alley or lane is required alley is required 1 These standards apply to: — swales (measured to edge of pavement); — raised curbs if both on-street parallel parking and curb bulbs (curb extensions) are provided (measured to vertical face of curb); and — raised curbs if on-street parallel parking is not provided (measured to vertical face of curb); 2 This standard applies to: — raised curbs if on-street parallel parking is provided without curb extensions (measured to vertical face of curb). 3 This standard applies to: — 1 tree for each thirty (30) linear feet for regular spacing; and — average of 1 tree for each thirty (30) linear feet for irregular or opportunistic spacing. k. Street Network Design. (1) New development must accommodate the Future Street Network Plan (see Section 4.04.04.B). (2) Each neighborhood must provide an interconnected network of streets, alleys or lanes, and other public passageways. i. Neighborhood streets must be designed to encourage pedestrian and bicycle travel by providing short routes to connect residential uses with nearby commercial services, schools, parks, and other neighborhood facilities within the same or adjoining Towns or Villages. Sidewalks and rows of street trees must be provided on both sides of all neighborhood streets. ii. Neighborhood streets should be organized according to a hierarchy based on function, size, and design speed. Rights-of-way are expected to differ in dimension and must meet the appropriate standards for the transect zones in Page 397 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 36 of 62 which they are located (see Section 3.01.03.EE.2.i). There must be a minimum of two (2) street types within each neighborhood. iii. Neighborhood streets do not have to form an orthogonal grid and are not required to intersect at ninety-degree angles. These streets may be curved or bent but must connect to other streets. Jogs or centerline offsets shall be at least one hundred (100) feet for local streets; this requirement does not apply to alleys. iv. Neighborhoods must accommodate one (1) or more public transit nodes for service to points beyond the neighborhood. v. All streets must be publicly dedicated. Private streets and closed or gated streets are prohibited, notwithstanding the provisions of Sections 7.05.03.E and 7.10.15. vi. The use of raised intersections, lateral shifts, and traffic circles are encouraged as alternatives to more conventional traffic calming measures such as speed bumps. vii. A continuous network of rear and side alleys and/or lanes is desirable to serve as the primary means of vehicular ingress to individual lots. Such networks are mandatory in Core and Center transect zones and for Mixed use, Retail, Live/Work, Apartment, and Rowhouse, and Cottage Lots regardless of transect zones. Alley and rear lane entrances should align so as to provide ease of ingress for service vehicles. Internal deflections or variations in the alley/rear lane network are encouraged to prevent excessive or monotonous views of the rear of structures resulting from long stretches of alleys and rear lanes. viii. Cul-de-sacs are not permitted except where physical conditions such as freeways provide no practical alternatives for connection for through traffic. Canals may or may not be physical barriers; appropriate crossings will be considered at the time of PTV approval. Each cul-de-sac must be detailed as a close, with landscaping in the center (see Figure 3-9). ix. Street stubs must be provided to adjacent undeveloped land to ensure an integrated street network is achieved over time, except where the adjacent land is being designated as Countryside through the PTV approval. Stub-out streets to connect to future development will not be considered cul-de-sacs if they are less than three hundred (300) feet long. Page 398 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 37 of 62 x. Full access intersections along Indrio Road must be separated by at least six hundred sixty (660) feet. Full access intersections along other roads on the regional street network must be separated by at least three hundred thirty (330) feet (see Section 4.04.04.B). (3) The average perimeter of all blocks within a neighborhood may not exceed 1,500 feet. The maximum perimeter of any block may not exceed 2,400 feet. The portion of any block between intersecting streets may not exceed 500 feet without a publicly dedicated pedestrian sidewalk or trail providing access to another street. Smaller block sizes are encouraged to promote walkability. An applicant may propose minor modifications to these block size standards during the PTV rezoning process; the Board of County Commissioners shall decide whether to accept, modify, or reject such modifications during the approval process based on consistency with the goals, objectives and policies of the TVC Element and the applicable site plan approval standards in Chapter XI of this Code. (4) The Edge Drive street type is intended to demarcate the Edge transect zone from the Countryside. Edge Drives are primarily "single-loaded," having private lots on one side while providing visual and often physical access to the Countryside on the other. A double- loaded Edge Drive is limited to 30% of the linear edge; where Edge Drives are double- loaded, a physical line of demarcation (e.g. a split rail fence) must be provided separating private lots from public trails and the Countryside. An applicant may propose to exceed the 30% limitation during the PTV rezoning process where there is no significant view of the Countryside that would be lost or where it is deemed to be in the balanced public/private interest while remaining consistent with the TVC Element. The Board of County Commissioners shall decide whether to accept, modify, or reject a proposed increase in double-loaded Edge Drive during the approval process based on consistency with the goals, objectives and policies of the TVC Element and the applicable site plan approval standards in Chapter XI of this Code. (5) In addition to its network of streets, each PTV shall also include a network of trails or greenways connecting urban, recreational, academic, and rural locations. Trails shall be provided along the Flow Way System and along remaining canals to provide connections and access to the Countryside. Trails in the Fringe transect zone should be located in the center of the Fringe zone or adjacent to the Rural zone to provide separation from private lots in the Edge zone. Existing hedgerows, environmentally significant or sensitive lands, tree clusters, flow ways, knolls, and viewsheds from scenic roads or parkways shall be considered for connecting linkages between Towns and Villages. Greenway lands shall be interconnected wherever possible to provide a continuous network of such lands within and adjoining each PTV and remaining separated from streets wherever possible. (6) The street design requirements of Section 7.05 apply except where they conflict with standards for the TVC Overlay Zone or this zoning district. Further exceptions to the requirements of Section 7.05 may be authorized by the Board of County Commissioners through approval of a regulating plan during the PTV rezoning process. l. Street Cross-Sections. Street types in all PTV districts must be assigned in accordance with Section 3.01.03.EE.2.i. The specific design of each street must follow the cross-sections illustrated below for each street type, as adjusted for the transect zone they pass through in accordance with Section 3.01.03.EE.2.j. The lane widths shown include the width of gutter pans. In the event of direct conflicts, these standards shall supersede other standards in this Code or in public works manuals. Page 399 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 38 of 62 Page 400 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 39 of 62 Page 401 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 40 of 62 Page 402 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 41 of 62 Page 403 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 42 of 62 Page 404 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 43 of 62 m. Off-Street Parking Regulations. Certain modifications are needed to the off-street parking regulations found in Section 7.06.00 of this Code. Planned Towns or Villages provide extensive on-street parking, a mix of compatible land uses, sidewalks and trails, and rear alleys or lanes. Based on these factors, the following modifications will apply: (1) The following minimum dimensions for parking access aisles and standard parking stalls apply in lieu of the specific requirements in Section 7.06.00: Aisle Width (feet) Parking Stalls (feet) Angle of parking (degrees) Two-Way One-Way Width Length 90° 22 20 9 18 Page 405 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 44 of 62 75° 22 18 9 18 60° 20 16 9 18 45° 20 14 9 18 30° 20 14 9 18 0°(parallel) 18 14 8 20 (2) Wherever possible, parking lots shall be located behind buildings so that buildings can screen parking areas from sidewalks and streets. In no case may parking be located in front of a building. Small parking lots in side yards may be permitted provided the buildings they serve can meet the lot width and building frontage requirements of Table 3-1 and provided these lots are set back a minimum of twenty (20) feet from lot lines adjoining rights-of-way, excluding alleys or lanes. (3) The following multipliers shall be applied to the required number of off-street parking spaces shown in Section 7.06.02. The result of this multiplication will be the required number of off-street parking spaces in each transect zone. Neighborhood Transect Zones Land Use Type Ed ge Ge ne ra l Ce nt er Co re Residential 100% 75% 60% 50% Hotel/Motel n/a n/a 70% 60% Religious Facilities 75% 60% 50% 40% Places of Public Assembly n/a n/a 50% 40% School or College n/a n/a 50% 40% Medical/Dental Office n/a n/a 50% 40% Eating or Drinking Establishments n/a n/a 50% 40% General Office n/a n/a 50% 40% Business or Personal Services n/a n/a 50% 40% Retail Stores n/a n/a 50% 40% Museums or Galleries 75% 60% 50% 40% Libraries 75% 60% 50% 40% (4) Access to Off-Street Parking. i. In the Core and Center transect zones, alleys or lanes shall be the primary source of access to off-street parking. In the General and Edge transect zones, alleys or lanes are the desirable source of access to off-street parking. Parking along alleys or lanes may be head-in, diagonal, or parallel. ii. Alleys or lanes may be incorporated into parking lots as if they were standard parking access aisles. Access to all properties adjacent to the alley must be maintained. iii. Access between rear parking lots across property lines is strongly encouraged. iv. Residential buildings on individual lots must meet the garage standards in Section 4.04.04.F. (5) Parking structures are permitted only in the Core and Center transect zones and must be no taller than four (4) stories and must be separated from adjacent streets by liner Page 406 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 45 of 62 buildings at least two (2) stories in height and no less than twenty (20) feet in depth. Liner buildings may be detached from or attached to parking structures. (6) Landscaping for off-street parking and loading areas shall, as a minimum, meet the requirements of Section 7.09.00. n. Civic Spaces and Civic Buildings. (1) Civic Spaces. Civic spaces must be designed and configured to be clearly recognizable as public open space. Civic spaces should be located so that building walls having at least fifteen percent (15%) of their area in transparent windows will face the space to make the space safer for the public. Each neighborhood must have at least four (4) separate civic spaces, which may include neighborhood parks, greens, squares, plazas, and playgrounds. i. Each civic space should be consistent with the character of the transect zone in which it is located. For example, a plaza located in the Core or Center transect zone would be detailed with hardscaping and a formal planting pattern of a single species (see Figure 3-10), while a neighborhood park in the Edge transect zone may be green with paths through an informal planting pattern of multiple species (see Figure 3-11). ii. Each civic space must have at least twenty-five percent (25%) of its perimeter and at least two (2) sides directly adjoining a street. iii. Except for civic spaces located along the periphery of a neighborhood, the combined size of all civic spaces located within a neighborhood must be at least two and one-half percent (2.5%) but no more than seven and one-half percent (7.5%) of the total acreage assigned to the Core, Center, General, and Edge transect zones. iv. Each civic space must provide shaded seating and a water fountain. v. Civic spaces placed in Fringe and Rural transect zones are not affected by nor counted toward these civic space requirements. (2) Civic Buildings. Civic buildings contain uses of special public importance and must be designed to physically express that prominence. Civic buildings include, but are not limited to, municipal buildings, churches, libraries, schools, day care centers, recreation facilities, and places of assembly. Civic buildings do not include retail buildings, residential buildings, or buildings with private offices. Page 407 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 46 of 62 i. Each neighborhood must contain at least three (3) Civic Building Lots. Civic Building Lots are usually sited to adjoin civic spaces or to provide visual landmarks by being placed at the axial termination of streets (see Section 3.01.03.EE.2.f (9)). At least one (1) civic building must be constructed within two (2) years after development commences. ii. In order to provide greater flexibility in building types and to allow more distinctive architectural expression, Civic Building Lots do not include building frontage or front yard standards. iii. Oversized Civic Building Lots such as those sometimes required for public schools or for churches with regional congregations should be located at the periphery of neighborhoods so as not to impede the walkability of the remainder of the neighborhood. o. Open Space and Countryside Standards. (1) Purpose and intent. i. Land in the Countryside is an integral component of each Town and Village for the following purposes: 1) Preserving and enhancing rural character between neighborhoods; 2) Preserving and restoring native habitats; 3) Providing opportunities for sustained agriculture; 4) Mitigating the biological and ecological impacts of new development; and 5) Accommodating the Flow Way System which includes water storage to serve the neighborhoods (see Section 3.01.03.EE.2.p). ii. To maximize both the aesthetics of the rural landscape and the biological and ecological systems intended by the Countryside requirements, Towns and Villages must link to the greatest extent possible the areas set aside for these purposes both within the site as well as to any existing neighboring Countryside areas, existing or planned passive parks, existing uses of an agricultural character, or environmental preserves. iii. For purposes of this Code, two (2) transect zones are used to designate the appropriate locations for most Countryside components: the Fringe zone which adjoins neighborhoods or other public spaces, and Rural zone which does not adjoin neighborhoods. (2) Open Space and Countryside requirements. i. To ensure that the rural landscape is preserved, large areas of Towns and Villages must be reserved for Open Space and Countryside. Specific percentage standards for Open Space and Countryside are established for each new Town or Village in Section 3.01.03.EE.2.b. ii. The required Countryside percentage may be fulfilled by land that is restricted to a combination of the following components: 1) Agricultural uses and facilities, including farmer's markets and agriculture-based targeted industry; Page 408 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 47 of 62 2) Restored or preserved native habitat and environmentally significant or sensitive l and (see Section 3.01.03.EE.2.o(4)); 3) The Flow Way System including adjoining water management facilities and wastewater re-use facilities (see Section 3.01.03.EE.2.p); 4) Community recreation areas such as community or regional parks, recreational fields, picnic areas, primitive campgrounds, greenways, and trails, provided they: a) Link with trails to neighborhoods and adjacent Countryside areas; b) Provide opportunities for shaded seating; and c) Provide facilities such as public restrooms and water fountains; 5) Civic spaces including neighborhood parks, greens, squares, plazas, and playgrounds, provided they are publicly accessible in perpetuity (see Section 3.01.03.EE.2.n); and 6) Golf course (limited to eighteen (18) holes per Town or Village), provided that it does not interfere with the creation of a continuous flow way and integrated trail system, remains open to the public, accommodates re- use wastewater, and uses Best Management Practices for Florida Golf Courses published by the Institute of Food and Agricultural Sciences at the University of Florida in 1999. iii. Where Section 3.01.03.EE.2.b. provides that up to ten percent (10%) of a new Town or Village may be designated Open Space in lieu of Countryside, this allowance may be fulfilled by land that is restricted to a combination of the following Open Space components; however, all Fringe or Rural areas that are not designated in the regulating plan as reserved for an Open Space or Countryside component shall be limited in the future to Countryside uses: 1) Civic uses, as defined in Section 4.04.06, including the playfields associated with a school (see Section iii.7); 2) Targeted industry (as defined in Section 4.04.06 and discussed in Section 3.01.03.EE.2.r) (see Section iii.7); 3) Higher education (as defined in Section 4.04.06) (see Section iii.7); 4) Parking garages or portions thereof, provided they meet the following requirements: a) Parking spaces in the garage are unassigned and are available to the general public or to nearby customers, employees, or residents at up to market-rate parking fees. b) The parking garage contains at least four (4) levels of parking spaces. c) Any parking spaces dedicated solely for the use of individual patrons, businesses, or residential complexes must be subtracted, along with their pro-rata share of ramps and aisles. 5) Estate Lots, which may occupy up to five percent (5%) of the land area for Open Space and Countryside, but must be included in the ten percent (10%) allocation of the site permitted for Open Space components. Page 409 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 48 of 62 Additionally, the allowance for these lots must be acquired by TDR Credits transferred from an off-site eligible sending site (see Section 4.04.05); and 6) The total area of lots for workforce housing that is being provided above the eight percent (8%) that is required in a Town or Village (see Section 3.01.03.EE.2.q), but not counting any accessory dwellings as described in Section 3.01.03.EE.2.g(3). 7) Parking areas (including access drives and aisles) that serve civic uses, targeted industry, and higher education can be counted as Open Space components; reduced asphalt and pervious surfaces are encouraged. 8) Solar generation station, subject to the supplemental standards in Section 7.10.28. iv. Some of the required Countryside percentage may be fulfilled by non- contiguous acreage within the TVC area provided that this acreage is included in the proposed PTV zoning district and is similarly restricted to Countryside uses. v. Except for approved Estate Lots, the transferable development rights assigned to Fringe and Rural transect zones and to other land designated as Open Space components is formally transferred to neighborhoods in a Town or Village upon approval of a PTV application. Depending on the components identified for the land dedicated to the required percentage of Countryside, a multiplier may be applied to the transferable development rights pursuant to the TDR program (see Section 4.04.05). At the time of final site plan approval for the PTV, evidence of this transfer must be recorded in the public records of St. Lucie County through a conservation easement acceptable to the County Attorney and meeting the requirements of Section 4.04.05.H, Conditions of the Conservation Easement or Deed Restriction. (3) Location of Open Space and Countryside components in the transect. Open Space and Countryside components shall be located and arranged within the transect as described in this subsection. Figure 3-12 illustrates this description by applying vertical hatching to typical locations of Open Space and Countryside components. Page 410 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 49 of 62 i. Within the PTV zoning district, the Flow Way System is to be designated as a Rural or Fringe transect zone. Where the Flow Way System runs through a neighborhood, its edges should reflect the character of adjacent transect zones as described in Section 3.01.03.EE.2.p. ii. The continuation of viable agricultural uses in the Countryside and on neighboring properties is a primary design goal for the Countryside. Such uses constitute unique and irreplaceable resources and are major contributors to the economy. The assignment of transect zones must accomplish this goal in a manner consistent with Florida's Right to Farm Act. Once transect zones are assigned, the following limitations apply to agricultural uses and facilities within the PTV: 1) Agricultural uses and facilities in the Fringe transect zone are limited to passive agriculture that is compatible with nearby residential uses such as, but not limited to, horse and cattle pasture and native range. 2) Active agricultural uses must be located only in the Rural transect zone; such uses include crops that require extensive cultivation or spray applications of pesticide and fertilizer and concentrated livestock facilities. 3) Agricultural or utility uses or facilities that may generate noise or odor must be located only in the Rural transect zone. iii. Other Countryside components shall also be located in the Fringe and Rural transect zones, except for community recreation areas which may be located in any transect zone. iv. Open Space components may be located within any of the four (4) neighborhood transect zones, except that Estate Lots may be located in the Fringe transect zone when limited in accordance with the footnote to Table 3-2. (4) Countryside uses (Fringe and Rural transect zones). Land in the Fringe and Rural transect zones may be used only for the following purposes, and structures are allowed only to serve these permitted uses: i. Agricultural uses and facilities including farmer's markets and agriculture-based targeted industry, except as follows: 1) Agricultural uses and facilities in the Fringe transect zone are limited to passive agriculture that is compatible with nearby residential uses such as, but not limited to, horse and cattle pasture and native range. 2) Active agricultural uses must be located only in the Rural transect zone; such uses include crops that require extensive cultivation or spray applications of pesticide and fertilizer and concentrated livestock facilities. 3) Agricultural or utility uses or facilities that may generate noise or odor must be located only in the Rural transect zone. ii. Restored or preserved native habitat and environmentally significant or sensitive land (see Section 3.01.03.EE.2.o(4)); iii. The Flow Way System including adjoining water management facilities and wastewater re-use facilities (see Section 3.01.03.EE.2.p); Page 411 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 50 of 62 iv. Community recreation areas such as community or regional parks, recreational fields, picnic areas, primitive campgrounds, greenways, and trails, provided they: 1) Link with trails to neighborhoods and adjacent Countryside areas; 2) Provide opportunities for shaded seating; and 3) Provide facilities such as public restrooms and water fountains. v. Civic uses on Civic Building Lots; vi. Golf course (limited to eighteen (18) holes per Town or Village), provided that it was designated on an approved PTV regulating plan, does not interfere with the creation of a continuous flow way and integrated trail system, remains open to the public, accommodates re-use wastewater, and uses Best ManagementPractices for Florida Golf Courses published by the Institute of Food and Agricultural Sciences at the University of Florida in 1999; and vii. Allowable residential uses on Estate Lots. Estate Lots in the Fringe transect zone are limited to a maximum of five percent (5%) of the land area dedicated to Open Space and Countryside; the allowance for these lots must be acquired by TDR Credits transferred from an off-site eligible sending site (see footnote to Table 3-2). (5) Restoration and preservation. The restoration and preservation of native habitats and environmentally significant land is strongly encouraged in the Fringe and Rural transect zones. Restored habitats may qualify for increased TDR credits as described in Section 4.04.05 if they meet the following minimum standards: i. Restored habitats are at least twenty-five (25) acres in size; ii. Restored habitats are connected to the greatest extent possible to existing preserved native habitat or preserved environmentally significant land or to the Flow Way System; iii. Restored habitats must include multiple upland and wetland habitat types consistent with habitat types that can be supported by the existing soil types and the proposed hydrology for the site; iv. Restored habitats include only native species in the canopy, understory, and groundcover in proportions similar to those found in representative naturally occurring plant communities in St. Lucie County; and v. Shallow marsh systems are encouraged. Deep water habitat and the required littoral zone and upland buffer habitat (Section 3.01.03.EE.2.p(4)(ii)and (iii)) are not eligible for restoration credit, but shallow marsh acreage beyond the requirements may be eligible for full restoration credit. vi. Proposals that request an increased multiplier for transferable development rights based on creating or restoring natural habitats from former agricultural lands must be accompanied by a restoration and management plan. The Board of County Commissioners will decide whether to accept or modify such plans during the PTV approval process. The restoration and management plan must include the following: 1) Identifies the area to be restored; Page 412 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 51 of 62 2) Identifies the strategy that will be employed to restore the land; 3) Provides an acceptable time table for completion of the restoration; 4) Identifies measures that will be used to evaluate the success of the restoration, including the density and distribution of species; and 5) Includes a funding strategy for monitoring and maintaining the habitat, including the ongoing maintenance and removal of exotic vegetation. (6) Use of reclaimed water. i. Each new Town or Village must propose a reclaimed water management plan which: 1) Meets the design standards of FDEP and SFWMD and is capable of meeting water quality standards for ultimate discharge into the Indian River Lagoon; 2) Accommodates within its PTV boundaries the volume of reclaimed water produced from its wastewater discharges; 3) Identifies the lands designated to receive reclaimed water; 4) Encourages subsurface drip irrigation systems; 5) Prioritizes the irrigation of agricultural lands and golf courses as the preferred method of re-use; and 6) Provides secondarily, and as necessary to accommodate the required disposal volumes, applications on other land uses allowed by FDEP. ii. The reclaimed water management plan shall be reviewed and approved by the utility providing the re-use water. Documentation of such approval must be available prior to public hearings on the PTV request. iii. These requirements were established to offset the biological impacts of new development, to ensure the re-use of nutrients in reclaimed water, to enhance the ecological functions of the Countryside, and to enhance the county's strategy of disposing of reclaimed water near its origin. (7) Countryside management. Land in the Countryside, regardless of use or ownership, is a critically important landscape component of St. Lucie County and must be properly managed and maintained to further the purposes of the TVC Element. A detailed countryside management plan must be submitted with each PTV application identifying the entities that will be responsible for the funding, construction, ownership, and management of each component of land designated as Countryside, specifically including the Flow Way System. The Board of County Commissioners will decide whether to accept or modify this plan during the PTV approval process. p. Regional Flow Way System. (1) Purpose and intent. i. A regional Flow Way System will improve water quality through a comprehensive interconnected storm water management system that also serves as a linear park. The Flow Way System is intended to provide for a high level of retention and treatment of stormwater, reduction in water lost to tide through storage and re-use of retained water, supplemental water supply for Page 413 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 52 of 62 irrigation, habitat for fish and wildlife, wildlife corridors, opportunities for habitat mitigation, and the recreational and aesthetic values provided by natural riverine systems. ii. The regional Flow Way System will be created incrementally and become a continuous water management system that enhances the conveyance functions of the existing drainage canals and incorporates the storm water detention, conveyance, and discharge systems for new development so as to reduce total runoff volume and improve water quality prior to discharge into the Indian River Lagoon. iii. Where not inconsistent with SFWMD permitting criteria, natural habitat restoration is preferred to open water systems for treating stormwater and may be eligible for higher multipliers offered for restoration and preservation. (2) Location and connectivity. i. The Flow Way System shall be integrated within each development site as well as with adjacent flow way systems and existing human and native habitats in order to create a fully integrated regional system. ii. The Flow Way System shall be located within the Fringe or Rural transect zones where it can provide sufficient water storage to serve the neighborhoods while maximizing the viability of the adjacent land for agricultural uses and native habitat restoration. The system may pass through or between neighborhood transect zones provided the following criteria are met: 1) The location and width of that portion of the system does not negatively impact the desired walkable, compact structure required for each Town or Village; 2) An adequate number of crossings is provided in order to maintain the required connectivity of the street network and the navigability of the waterway; and 3) That portion of the system is detailed to reflect the appropriate urban or rural character of the neighborhood transect zones (see Figure 3-13). (3) Accessibility and edges. i. In order to reinforce the desired linear park quality intended for the Flow Way System, the water's edge must be easily and safely accessible. A pedestrian and bicycle trail system shall be provided and maintained along at least one (1) side of the system. In neighborhoods, the trail may take the form of paved sidewalks that runs adjacent to the system. In the Countryside, trails of a suitable material for walking, cycling, or equestrian uses should be provided within the upland buffer adjacent to the system. ii. The edge of the Flow Way System should be varied and should reflect the character of the adjacent transect zone. The following edge conditions may be used (as illustrated in Figure 3-13) or other designs may be submitted for approval consistent with the following intent: 1) Neighborhood: Core, Center. Near the center of Towns and Villages, the system may be bulkheaded with adjacent sidewalks, railings, and formal landscaping. Bulkheaded sections should provide periodic access via stairs and landings to the waters' edge. Page 414 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 53 of 62 2) Neighborhood: General, Edge. The area from the waters' edge landward should be fairly level to gently sloping for a minimum of fifteen (15) feet, with any required elevation changes to an adjacent sidewalk accommodated by terraces or landscaped slopes. Landscaping may be either formal or informal, with care given to species selection on sloped areas for long-term maintenance. 3) Countryside. In order to create a natural relationship between land and water within the Countryside, the slope of the land from the water's edge landward shall be no steeper than one (1) foot of vertical change in elevation for every ten (10) feet of horizontal distance for the first twenty (20) feet landward from the waters' edge. A wide walking path can meander along the edge of the water within native habitat. This edge condition may also be appropriate along a park. (4) Fish and wildlife. i. The Flow Way System is intended to provide fish and wildlife habitat in addition to its other functions. In order to promote use by wildlife, wading birds, and in particular endangered species such as the wood stork, the system must be designed and managed to provide wading bird feeding areas and healthy fish populations. ii. A vegetated and functional littoral zone shall be established as part of the Flow Way System. Prior to construction of the surface water management system for any phase of a project, the developer shall prepare a design and management plan for the littoral zone that will be established as part of these systems. The Page 415 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 54 of 62 littoral zone established shall consist entirely of native vegetation and shall be maintained as part of the water management system. 1) As a minimum, twenty (20) square feet of vegetated littoral zone per linear foot of shoreline shall be established as part of the water management system. 2) This area of vegetated littoral zone habitat shall be located such that no less than fifty percent (50%) of the total shoreline of the Flow Way System is buffered by littoral zone habitat. 3) Littoral zone habitat shall be a minimum width of twenty (20) feet and a minimum of twenty-five percent (25%) of the shoreline shall be designed as a wide littoral zone habitat a minimum of sixty (60) feet in width (see Figures 3-14 and 3-15). For example, one hundred (100) feet of shoreline requires two thousand (2,000) square feet of littoral zone along at least fifty (50) feet of the Flow Way edge; twenty-five (25) feet of the fifty (50) feet of shoreline with littoral zone must be sixty (60) feet wide. 4) Average water depth over the littoral shelf should range between two (2) to eighteen (18) inches at the control elevation. The littoral shelf should be contoured to create areas with shallow depressions that should dry down or retain two (2) to six (6) inches of water when the water level is one (1) foot below the control elevation (see Figure 3-15), except for points of inflow which may be deeper. 5) These littoral areas are considered part of the Flow Way System and are not eligible for the higher multiplier offered for restored native habitat by the TDR program. iii. A buffer zone of native upland edge vegetation shall be provided and maintained around the Flow Way System. The habitat may consist of preserved or planted vegetation, but shall include canopy, understory, and ground cover of native species only. The edge habitat shall begin at the upland limit of the Flow Way System. As a minimum, twenty (20) square feet of edge habitat shall be provided for each linear foot of shoreline. This upland edge habitat shall be located such that no less than fifty percent (50%) of the total shoreline is buffered by a minimum width of twenty (20) feet of upland habitat. This edge habitat is considered part of the Flow Way System and is not eligible for the higher multiplier offered for restored native habitat by the TDR program (see Figures 3-14 and 3-15). Page 416 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 55 of 62 (5) Navigability. i. The Flow Way System shall be designed primarily for water quality and restoration purposes. When consistent with these primary purposes, navigability by non-motorized boats is also a design goal. Where SFWMD requirements prevent navigation due to required separations or features such as existing canals or spillways, easy portage opportunities shall be provided at such obstructions. ii. Except where navigability would be inconsistent with the water quality and restoration goals for the Flow Way System, bridge crossings must provide at least four (4) feet of clearance between the system's control elevation and the bottom of the bridge crossing. Large culverts may be used to provide navigability if this clearance standard can be met. (6) Planning and maintenance. i. Planning. The Flow Way System must be designed to the following standards and incrementally constructed as development proceeds: 1) All elements of the stormwater management system must be designed to prevent negative impacts to adjacent areas and to receiving water bodies. The developer must establish a permanent water quality monitoring system to demonstrate that adjacent properties and receiving bodies of water are not being negatively impacted by water not meeting standards. The proposed monitoring system requires approval by St. Lucie County in consultation with SFWMD prior to construction of the surface water management system. 2) Water attenuation and discharge criteria must use the ten-year, three- day storm event with a peak discharge rate of 2.6 inches per twenty-four (24) hours, or the criteria required by SFWMD, whichever is more restrictive. Each portion of the Flow Way System must meet all permitting criteria required by SFWMD. 3) Best Management Practices must be used to ensure water quality. 4) Before final approval is granted to excavate, a Phase I environmental assessment, and if warranted a Phase II environmental assessment, shall be submitted to St. Lucie County. If levels of contaminants in the soil such as pesticides, herbicides, and metals are found to exceed state standards, the area shall be remediated or the site redesigned to accommodate storm water management in another location. 5) Once St. Lucie County creates an institutional structure to facilitate the implementation of the Flow Way System, further approvals must be in accordance with that structure. ii. Maintenance. The long-term operation, management, and maintenance of the overall system should be conducted by a single entity responsible to meet the performance criteria set forth for the regional system. These responsibilities shall include the following: 1) Provide connectivity between Towns, Villages, and other developments; 2) Manage the health of the aquatic system; Page 417 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 56 of 62 3) Manage the fish and wildlife values; 4) Provide navigability between Towns and Village; and 5) Provide and implement mitigation as needed. q. Workforce Housing. To encourage a broad range of family sizes and incomes, each Town and Village must provide a minimum of eight percent (8%) of the proposed number of dwellings as workforce housing, as defined generally in Section 4.04.06 and as further defined by St. Lucie County through ordinances or during the process of approving an individual Planned Town or Village. (1) When workforce housing will be provided above the required eight percent (8%), the total area of its lots may be counted towards the fulfillment of the required amount of Countryside, but may not be located in either the Rural or Fringe transect zones. i. Accessory dwellings in neighborhoods may provide additional workforce housing, but such dwellings may not be counted towards the fulfillment of either the eight percent (8%) workforce housing requirement or the required amount of Countryside. ii. Accessory dwellings and any workforce housing above the required eight percent (8%) that is not counted toward the fulfillment of the required amount of Countryside will not be required to comply with the remaining provisions of Section 3.01.03.EE.2.q. (2) Workforce housing must be made available on approximately the same schedule as the balance of housing in each Town or Village; workforce housing may not be deferred until the final phases. i. A specific schedule for the types, location, and phasing of construction of workforce housing must be proposed with each PTV application. ii. The Board of County Commissioners shall decide whether to accept or modify this schedule during the approval process based on consistency with the goals, objectives and policies of the TVC Element and the applicable site plan approval standards in Chapter XI of this Code. (3) Workforce housing units must be roughly proportional to the tenure types (fee simple, condominium, rental) of the market rate homes in each Town or Village. (4) The bedroom mix of workforce housing units must be roughly proportional to the bedroom mix of the market rate homes in each Town or Village. (5) Workforce housing units are expected to vary from the market rate offerings in each Town or Village due to smaller sizes and fewer interior amenities. However, these variations must not adversely affect the energy efficiency of the workforce units. Workforce units must be complementary in exterior design and materials and must be dispersed throughout each Town or Village. (6) Workforce housing must be sold or rented only to qualified households as defined by St. Lucie County. i. Half of the required workforce housing must be affordable to families earning eighty percent (80%) to one hundred percent (100%) of the Area Median Income. The other half must be affordable to families earning one hundred percent (100%) to one hundred twenty percent (120%) of the Area Median Income. Page 418 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 57 of 62 ii. Workforce housing may be offered for sale or rent through agencies operating affordable housing programs that are specifically approved by the St. Lucie County for this purpose. (7) Affordability must be maintained for a minimum of eight (8) years, or the period of affordability specified by the funding secured by the developer, whichever is longer. St. Lucie County will establish standards for maintenance of affordability during this period. i. These standards may include documents being recorded in the public records of St. Lucie County describing the affordability requirements for each workforce housing unit. ii. These standards may include a program that would restrict the resale of individual workforce housing units or the subsequent rental of a purchased unit only to other qualified households as defined by St. Lucie County. iii. These standards may include a program for setting resale prices for individual workforce housing units to maintain affordability and resetting the twenty-five- year affordability period upon resale, and may provide for appreciation in the value of the unit to accrue to the seller in increasing percentages based on the length of time that the unit is occupied by a qualifying household. r. Targeted Industries. St. Lucie County identifies targeted industries that will enhance industry clusters vital to the county's economic future and that will expand job opportunities for county residents. These targeted industries are defined by St. Lucie County through its economic development program and may be adjusted during the process of approving an individual Planned Town or Village. In addition to other incentives provided by St. Lucie County: (1) Manufacturing Facilities identified by St. Lucie County as desirable targeted industries may be located within areas indicated on the Transferable Development Value Map (Figure 3-3 of the TVC Element) as suitable for industrial uses, excepting "aquaculture" which may be located within the Countryside of a PTV. (2) Distribution Centers identified by St. Lucie County as desirable targeted industries are suitable within areas indicated on the Transferable Development Value Map (Figure 3-3 for the TVC Element) as suitable for industrial uses or within areas west of I-95 that are identified on the North St. Lucie County General Workplace Plan (Figure 3-16 of the TVC Element) as appropriate for Highway Service/Warehouse. (3) Targeted industries categorized as Finance and Insurance Carriers; Information Industries; Professional, Science and Technical Services; or Administrative and Support Services may be located within Core or Center transect zones of a PTV. (4) Land that is developed for the sole use of targeted industries within a PTV may be counted as an Open Space component but may not be located in either the Rural or Fringe transect zones unless the use is agricultural in nature including aquaculture. See Section 3.01.03.EE.2.o(2)iii. (5) Development rights that are transferred from a targeted industry site are eligible for the highest multiplier offered by the TDR program (see Section 4.04.05). s. Landscaping and Natural Features. (1) In addition to complying with the Resource Protection Standards in Chapter VI, native trees and vegetation and other natural features must be preserved to the extent practicable. (2) The landscaping and screening requirements in Section 7.09 apply except as follows: Page 419 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 58 of 62 i. The landscaping adjacent to streets otherwise required by Section 7.09.04.A will not be required between buildings and streets. However, this requirement still applies between off-street parking areas (and other vehicular use areas) and streets. ii. The landscaped buffer areas required by Section 7.09.04.E to segregate single- family or two-family residential uses will not be required in the PTV zoning district. t. Signs. Permanent and temporary signs within any Planned Town or Village shall comply with the following provisions of Chapter IX of this Code: (1) For Rural and Fringe transect zones, the same regulations that apply to the Agricultural-5 (AG-5) zoning district, except that no off-premises signs are permitted. (2) For Edge and General transect zones, the same regulations that apply to the Residential Estate-2 (RE-2) zoning district. (3) For Center and Core transect zones, the same regulations that apply to the Commercial Neighborhood (CN) zoning district, except that ground signs may not exceed a height of ten (10) feet. 3. Approval Process. a. The approval process for the Planned Town or Village district shall be as provided in Chapter XI for Planned Developments, except that the approval of final site plans shall be administrative and shall not require the public hearing described in Section 11.02.05.B.4 or the public notices described in Section 11.00.03. This zoning district provides certain opportunities for applicants to request minor modifications to its standards. During the final public hearing for the preliminary approval of each PTV zoning district, the Board of County Commissioners must explicitly respond to each of these requests. Except to the extent that such requests are formally accepted or accepted with modifications, the written standards of this zoning district shall apply. b. Submittal requirements for preliminary approval shall be as provided for Planned Developments except as follows: (1) General Information: the same information required for all Planned Developments. (2) Existing Conditions: the same information required for all Planned Developments. (3) Proposed Development Activity and Design: the same information required for all Planned Developments except that the following items may be deleted: i. location of buildings; ii. location of parking/loading areas; iii. location of pedestrian circulation; iv. location of landscaping; v. location of signs and lighting; and vi. location of lots and yard requirements. (4) Preliminary Regulating Plan: In lieu of these deleted items, the applicant must submit a proposed preliminary regulating plan that complies with the following standards. This preliminary regulating plan may contain some or all of the other information required by this Code for a proposed development activity if that other information does not obscure the following required information for regulating plans: Page 420 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 59 of 62 i. The entire area within the proposed PTV and all adjoining roads, canals, and other rights-of-way or easements must be shown on the regulating plan. ii. A conceptual assignment of a transect zone to all land including proposed streets within the PTV (see Section 3.01.03.EE.2.c). All land shall be assigned one (1) of the six (6) transect zones and no land may be assigned two (2) or more transect zones. Conceptual assignments may be altered during final site plan as long as the intent remains consistent with transect percentage allocation requirements as outlined in Section 3.01.03.EE.3. iii. The approximate location of proposed streets throughout the PTV, indicating the specific type of each street. Streets types must comply with the transect zone through which they pass (see Section 3.01.03.EE.2.i) and must provide right-of-way in accordance with the standards in Section 3.01.03.EE.2.l. Street locations may be amended at final site plan in a manner that is consistent with the requirements of Section 3.01.03.EE. and the intent of the Preliminary Regulating Plan. iv. Proposed lot lines do not need to be shown on the regulating plan, but all land to be subdivided into lots must indicate the proposed lot types, which must comply with the transect zones where the lots are to be located (see 3.01.03.EE.2.e) and be able to meet the development standards for each lot type (see 3.01.03.EE.2.g) v. The approximate location of the surface water management system, including its outfall and all connections with existing drainage features and the new regional Flow Way System. vi. The location of civic spaces including those required by Section 3.01.03.EE.2.n, and if qualifying as Open Space components, the location of civic uses, targeted industry, higher education, estate lots in the Fringe transect zone, and workforce housing above the required eight percent (8%). vii. The graphic format of the regulating plan should be similar to the regulating plan in Section 3.01.03.EE.3.c and be produced at the same scale and sheet size as similar documents required for all Planned Developments. viii. The proposed regulating plan must be accompanied by tabular data demonstrating compliance with all requirements of the PTV zoning district. ix. The proposed regulating plan must be also be provided electronically in a standard CAD format. (5) Other Supporting Documents: The application should also contain other supporting documents that are required or that demonstrate compliance with the standards set forth in this Code and in the TVC Element. Examples include: i. A conceptual restoration and management plan (Section 3.01.03.EE.2.o.5). ii. A conceptual reclaimed water management plan (Section 3.01.03.EE.2.o.6) if such services are available on the subject property. iii. A conceptual countryside management plan (Section 3.01.03.EE.2.o.7). iv. A proposed schedule for the types, location, and phasing of construction of workforce housing for each phase (Section 3.01.03.EE.2.q). Page 421 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 60 of 62 c. Submittal requirements for final approval of a planned Town or Village shall be as provided in Chapter XI for final site plan approval of all other Planned Developments except as follows: (1) A final version of the preliminary regulating plan that was approved with the PTV zoning must be submitted which includes all of the information on the preliminary regulating plan plus the final location and dimension of all lots and streets in accordance with the PTV standards. (2) Final data tabulations that demonstrate compliance with all requirements of the PTV zoning district. (3) Other supporting documents and diagrams as needed to demonstrate compliance with the standards set forth in this Code and in the TVC Element, including final versions of Other Supporting Documents submitted with the Preliminary Regulating Plan. (4) Minor modifications to an approved preliminary regulating plan may be approved at the time of final approval, or later as an amendment to the final approval, provided they comply with all requirements of this Code, any conditions imposed at the preliminary approval stage, and with the goals, objectives, and policies of the TVC Element. No modifications may reduce the diversity of lot types or street types that had been shown on an approved preliminary regulating plan. d. A model regulating plan is shown in Figure 3-16 to demonstrate the graphic format and level of detail required when seeking preliminary approval for a Town or Village. This model regulating plan is reduced in size for inclusion in this Code but a full-scale copy of this plan may be obtained from the Growth Management Director. 4. Phasing of Towns and Villages. Preliminary approval of PTV zoning must be obtained for the entire Town or Village, including its Countryside component, even if subsequent development may occur in phases. If final approval is sought in phases, the first phase must include the entire Countryside component including recorded easements indicating that residential density has been transferred into Neighborhoods. Each phase must indicate how the remaining phases are planned to be integrated with the earlier phases. Tabular data must be provided at preliminary approval for the overall Preliminary Regulating Plan and for each future phase upon submittal for each Final PTV approval to ensure that all requirements of the PTV district will be met. Page 422 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 61 of 62 FIGURE 3-16a Page 423 of 456 Created: 2026-05-01 13:25:00 [EST] (Supp. No. 35) Page 62 of 62 FIGURE 3-16b Page 424 of 456 CHAPTER IV - SPECIAL DISTRICTS 4.04.00. TVC—OVERLAY ZONE (TOWNS, VILLAGES, COUNTRYSIDE) St. Lucie County, Florida, Land Development Code Created: 2026-05-01 13:25:03 [EST] (Supp. No. 35) Page 1 of 24 4.04.00. TVC—OVERLAY ZONE (TOWNS, VILLAGES, COUNTRYSIDE) 4.04.01. Purpose and Intent. The purpose and intent of Section 4.04.00 of this Code is to: A. Guide the creation of Towns, Villages, Hamlets, protected Countryside, and other permitted uses and development patterns on land designated TVC on the Future Land Use Map of the St. Lucie County Comprehensive Plan. B. Ensure that all development of land designated TVC takes place in accordance with the settlement principles set forth in the TVC Element of the Comprehensive Plan. Where this overlay zone directly conflicts with other portions of this Code, this overlay zone will prevail; however, no development may be approved that conflicts with the St. Lucie County Comprehensive Plan. C. Provide procedures for transferring development rights using TDR credits. Such transfers will allow continued rural uses of land that is designated TVC by transferring some or all of its development rights to Towns or Villages or to land within the Urban Service Boundary. (Ord. No. 2024-28, § Pt. B(Exh. A), 8-6-2024) 4.04.02. Essential TVC Concepts. Four (4) essential concepts for the regulation of land designated TVC are highlighted here: A. TVC Overlay Zone. This section of the code establishes a TVC Overlay Zone whose boundaries are identical to the TVC designation on the Future Land Use Map of the Comprehensive Plan as initially adopted in May 2006. This overlay zone provides general guidance and specific standards that, in conjunction with the remainder of this Code, will carry out the goals, objectives, and policies of the TVC Element. The TVC Overlay Zone contains two (2) sub-zones whose boundary is the Urban Service Boundary in the Comprehensive Plan as it existed in May 2006. The location and approximate boundaries of the TVC Overlay Zone and its sub-zones are shown on Figure 4-10. Comprehensive Plan amendments that make more than incidental adjustments to these boundaries will necessitate changes to this Code. Page 425 of 456 Created: 2026-05-01 13:25:02 [EST] (Supp. No. 35) Page 2 of 24 B. Urban-to-Rural Transect. Towns and Villages have physical forms that vary in character and intensity. An urban-to-rural transect that describes these characteristics in existing communities is also ideal for use as the organizing principle for new communities. New Towns, Villages and Planned Unit Developments on land designated TVC are to be planned using the "transect zones" shown on Figure 4- 11. These transect zones must be delineated on a regulating plan prepared by a developer and submitted to St. Lucie County for consideration as part of rezoning to the PTV (Planned Town or Village - see Section 3.01.03.EE) or PUD (Planned Unit Development - see Section 4.04.04.E(1)(b)) zoning district. C. Urban Service Boundary. The St. Lucie County Comprehensive Plan establishes an Urban Service Boundary (USB) which limits the geographic area where the county will provide certain services. The purpose is to restrict the negative impacts of a sprawling low-density development pattern including the fiscal burden placed on service providers by that pattern. About sixty-three percent (63%) of the land designated TVC is outside this boundary and the remainder is inside. The TVC Element provides incentives for moving potential development to new Towns and Villages or to certain locations inside the USB. Under certain circumstances the TVC Element allows new development to qualify for urban Page 426 of 456 Created: 2026-05-01 13:25:02 [EST] (Supp. No. 35) Page 3 of 24 services even if located outside the USB (see policies under Objective 3.1.2 of the St. Lucie County Comprehensive Plan). D. Transferable Development Rights. The development rights attached to a parcel of land can sometimes be transferred to other parcels. The TVC Element encourages the transfer of density for several purposes: to move potential development to certain locations inside the USB; To encourage continued use of land for rural and open space purposes by transferring potential density off the land; and to allow the accumulation of sufficient development rights to create Towns or Villages. Transferable development values are set in Figure 3-3 of the TVC Element and may be increased by using the multipliers in the TDR Credit Matrix in Table 3-4 of the TVC Element. See Section 4.04.05. (Ord. No. 11-002, § 4, 12-6-2011) 4.04.03. Overview of TVC Approval Processes. Development approvals for land designated TVC differ in several aspects from approvals in the remainder of unincorporated St. Lucie County. These processes can be summarized as follows: A. Owners of five hundred (500) or more acres of land located outside the USB and owners of one hundred ten (110) acres or more of land located inside the USB may seek approval of a new Town or Village by applying to rezone the land to the PTV (Planned Town or Village) zoning district. See Section 3.01.03.EE. Owners of five hundred (500) acres or more located outside the USB may also seek approval of a Hamlet by applying to rezone the land to the Hamlet PUD zoning district, pursuant to Sections 7.01.02 and 7.01.04. Any Hamlet proposed on land fronting Indrio Road must demonstrate consistency with Comprehensive Plan Policy 11.1.5.7. B. Owners of less than five hundred (500) acres of land outside the USB may take any of the following actions: 1. Maintain the land in its natural state or with agricultural uses consistent with its agricultural zoning district and utilize the Transfer of Development Rights (TDR) program to move at least ninety percent (90%) of the unused transferable development value from the land to an eligible receiving site. See Section 4.04.05. 2. Subdivide the land into individual home sites using the transferable development value assigned to that land by applying to rezone the land to the PCS (Planned Country Subdivision) zoning district. See Section 3.01.03.FF. Upon approval, the TDR program may not be used to transfer density to or from the land. 3. Utilize the Transfer of Development Rights (TDR) program to move or permanently set aside at least ninety percent (90%) of the transferable development value from the land and subdivide the land into individual home sites using the remaining development rights. See Section 4.04.04.D.3. 4. When consistent with the retail standards under Objective 3.1.8 of the TVC Element or the workplace standards under Objective 3.1.10 of the TVC Element, apply to rezone the land to the PRW (Planned Retail/Workplace) zoning district. See Section 3.01.06.GG. C. Owners of less than one hundred ten (110) acres of land inside the USB may take any of the following actions: 1. Develop or use the land for residential purposes in accordance with the TVC Overlay Zone requirements in Sections 4.04.01—4.04.06 of this Code. Page 427 of 456 Created: 2026-05-01 13:25:02 [EST] (Supp. No. 35) Page 4 of 24 2. Residential development is limited to the maximum residential densities on the Transferable Development Value Map (Figure 3-3 of the TVC Element), except that. a. Density may be increased as a county incentive for providing affordable housing, workforce housing, or mixed-use development. b. For development built in the form of a Town or Village, density may be increased through acquisition of TDR credits from eligible sending sites. See Sections 3.01.03.EE and 4.04.05. D. Owners of land of any size inside the USB (Urban Service Boundary) may place retail or workplace land uses outside a Town or Village by taking either of the following actions: 1. Seek rezoning of the land to the PRW (Planned Retail/Workplace) zoning district (Section 3.01.06.GG) if the proposed uses are fully consistent with the goals, objectives, and policies of the TVC Element, and in particular with the retail standards under Objective 3.1.8 and/or the workplace standards under Objective 3.1.10. Such proposals must also conform to the TVC Overlay Zone requirements of Section 4.04 of this Code. 2. Owners of property with existing commercial zoning (CO, CN, or CG) as of August 28, 2009, are not required to rezone to PRW, but must follow the development standards contained in Section 3.01.03.GG.2 for that zoning district and must otherwise be consistent with the TVC Element. All such proposals, except as necessary to achieve underlying nonresidential use intensity pursuant to Land Use Element Policies 3.1.2.5 and 3.1.3.1(4), must meet the retail standards under Objective 3.1.8 and/or the workplace standards under Objective 3.1.10, in addition to the TVC Overlay Zone requirements in Section 4.04 of this Code. E. Owners of land of any size may initiate, continue, or expand agricultural uses (including forestry and equestrian uses) in accordance with the requirements of the agricultural zoning district that applies to the land. This option is available both inside and outside the USB. See Section 3.01.03 for lists of permitted and conditional agricultural uses in each agricultural zoning district. (Ord. No. 11-002, § 4, 12-6-2011; Ord. No. 2024-28, § Pt. B(Exh. A), 8-6-2024) 4.04.04. TVC Specific Standards. A. Applicability of TVC Specific Standards. 1. The standards in Section 4.04.00 apply to land use and land development within the TVC Overlay Zone regardless of zoning designations, except as specifically provided. 2. The provisions of the remainder of this Code apply except where modified by this TVC Overlay Zone, by the PTV, PCS, PRW, or PUD zoning districts, or by the St. Lucie County Comprehensive Plan. B. Regional Street Network. 1. The TVC Element of the St. Lucie County Comprehensive Plan established in May 2006 a Future Street Network Plan that includes street improvements and new streets to be completed by the year 2030, as depicted on Figure 4-12. Page 428 of 456 Created: 2026-05-01 13:25:02 [EST] (Supp. No. 35) Page 5 of 24 2. St. Lucie County will not approve any construction or development of land that would interfere with the creation of or improvements to the streets identified on the Future Street Network Plan. 3. Development of land must accommodate and incorporate appropriate links of the Future Street Network Plan. Final alignments will be determined by St. Lucie County. Roadway capacity to support the proposed development must exist or be provided concurrently. Appropriate connectivity of new development to these streets and their integration with adjoining development must be demonstrated prior to development approvals. 4. Streets in the Future Street Network that connect rural areas to urban areas must provide transitions from higher design speeds in rural areas to lower design speeds for neighborhoods and other developed areas. Lower design speeds can be achieved by reducing the widths of travel lanes, clear zones, and medians. Lower design speeds can also be achieved by adding curbs, regularly spaced street trees, and on-street parking. C. Agricultural Uses. Owners of land are encouraged to initiate, continue, or expand agricultural uses (including forestry and equestrian uses) in accordance with the requirements of the agricultural zoning district that applies to the land; Section 3.01.03 for lists of permitted and conditional agricultural uses in each agricultural zoning district. This option is available to all land regardless of size both inside and outside the USB. At a Page 429 of 456 Created: 2026-05-01 13:25:02 [EST] (Supp. No. 35) Page 6 of 24 minimum, nothing in the TVC Overlay or other implementing regulations may be construed to supersede or interfere with agricultural rights protected under Florida's Right to Farm Act. Participation is optional in the Transfer of Development Rights program which allows unused transferable development value to be moved to an eligible receiving site (see Section 4.04.05). D. Residential Subdivisions Outside the Urban Service Boundary. Residential subdivisions may be created outside the Urban Service Boundary (USB) on land designated TVC only by following one (1) of these four (4) approaches: 1. As part of a new Town or Village, using the PTV zoning district (see Section 3.01.03.EE). 2. Outside a Town or Village through the use of the existing transferable development value assigned to a parcel of land, using the PCS zoning district (see Section 3.01.03.FF). 3. Outside a Town or Village after moving or permanently setting aside at least ninety percent (90%) of the transferable development value from the land to an eligible receiving site in accordance with Section 4.04.05: a. Transferable development value remaining on the land may be used to create residential lots in accordance with the standards of this Code including all TVC Overlay Zone standards. (1) There is no requirement to rezone from an existing AG-1 zoning district if the residential lots will comply with all AG-1 requirements. Such a development would be approved using the site plan approval process found in Chapter XI of this Code. (2) If the landowner wishes to allocate the remaining transferable development value in a more clustered manner, rezoning may be requested to PCS or other suitable zoning district. The rezoning application and subsequent site plan approval applications must be accompanied by a regulating plan that meets the standards of Section 3.01.03.EE.3.b(4) and that identifies appropriate transect zones (either Edge, General, or Center), lot types, and street types and that includes at least one (1) civic space in order to achieve development forms consistent with the TVC Element. b. Upon approval of this option, urban services may be extended at the property owners' expense to lots that use the remaining transferable development value despite being located outside the USB. c. The new residential lots must be placed on one (1) contiguous portion of the land and to the extent possible must provide an interconnected street network as described in Section 3.01.03.EE.2.k and water management in the form of an interconnected system consistent with and connected to the Flow Way System as described in Section 3.01.03.EE.2.p. 4. Outside a Town or Village, as a Hamlet Planned Unit Development (PUD), pursuant Sections 7.01.02 and 7.01.04. The Hamlet PUD shall consist of compact, pedestrian-friendly residential settlement with a variety of housing types. Home sites within a Hamlet PUD are eligible to receive urban services at the developer's expense. Development of a Hamlet PUD must ensure compatibility with existing or planned nearby development and provide connectivity of roadways, trails, open space, and a flow way. E. Residential Subdivisions Inside the Urban Service Boundary. 1. Residential subdivisions may be created inside the Urban Service Boundary (USB) on land designated TVC only by following one (1) of these two approaches: a. As part of a new Town or Village, using the PTV zoning district (see Section 3.01.03.EE). Planned Towns or Villages inside the USB require less acreage and a lower percentage of land to be designated as Countryside than for a Town or Village outside the USB (see Section 3.01.03.EE.2.b). Page 430 of 456 Created: 2026-05-01 13:25:02 [EST] (Supp. No. 35) Page 7 of 24 b. Outside a Town or Village but still inside the USB, using the transferable development value assigned to a parcel of land, plus any TDR credits acquired and/or any density bonuses that St. Lucie County may provide for affordable housing, workforce housing, or mixed uses. (1) If the land is not currently zoned to allow the desired density, the land must be rezoned to a suitable planned zoning district (for instance, see Sections 3.01.03.BB and 7.01.00, the standard planned unit development category and associated PUD regulations). The rezoning application and subsequent site plan approval applications must be accompanied by a regulating plan that includes the information required by Section 3.01.03.EE.3.b(4) and that identifies appropriate transect zones, lot types, and street types to achieve development forms consistent with the TVC Element. The required Center, General, and Edge transect zone percentages set forth in Section 3.01.03.EE.2.c(3) for Villages would apply to such land, unless the parcel is less than thirty-two (32) acres. The five-acre minimum parcel size for the standard PUD category would not apply to such an application. (2) Such residential subdivisions must provide an interconnected street network as described in Section 3.01.03.EE.2.k and water management in the form of an interconnected system consistent with and connected, if possible, to the Flow Way System as described in Section 3.01.03.EE.2.p. 2. Residential development on land designated TVC that is inside the Urban Service Boundary (USB) is afforded the following special allowances: a. Density may be increased in all proposed development inside the USB through acquisition of TDR credits from eligible sending sites (see Section 4.04.05). b. Transferable development rights are awarded higher multipliers when the receiving site is located inside the USB. F. Residential Driveways and Garages. 1. Intent. TVC Settlement Principles include public streets designed to meet the needs of all users, including pedestrians, bicyclists, and motor vehicles. In residential neighborhoods, an important walkability consideration is whether driveways, cars and on-street parking dominate the streetscape or continuous, wide, uninterrupted sidewalks and healthy street trees are provided. The intent of this sub-section is to ensure that residential garages and driveways do not compromise the walkability and intended pedestrian character of a neighborhood. 2. Applicability. The standards in this sub-section apply to new dwellings built in new subdivisions in the PTV, PCS, or PRW Zoning Districts and to new dwellings in new subdivisions approved pursuant to 4.04.04.D. and 4.04.04.E. Residential development on existing parcels and residential development in new subdivisions created pursuant to LDC sub-section 4.04.04.D.3. (after transfer of development rights) are exempt from these garage and driveway standards. 3. Garage and Driveway Standards. a. Front-loaded garage doors shall not comprise more than fifty percent (50%) of the width of the front elevation of the house (including the garage). b. Notwithstanding the previous provision, up to twenty percent (20%) of dwellings within a neighborhood can include garage doors which measure up to sixty percent (60%) of the width of the front elevation of the house. c. Different house types and lot widths must be dispersed throughout the neighborhood to provide variety to the streetscape. Page 431 of 456 Created: 2026-05-01 13:25:02 [EST] (Supp. No. 35) Page 8 of 24 d. Driveway width should be limited at the property line to protect the priority of the sidewalk and to enable on-street parking. In no case shall the driveway width exceed fifty percent (50%) of the lot width or twenty (20) feet, whichever is narrower, where the driveway meets the property line. Where measured elsewhere, single-family residential driveway widths shall not exceed twenty-two (22) feet. e. Front-loaded garages on residential lots greater than forty-five (45) feet in width shall be recessed from the main façade no less than ten (10) feet. The garage recess may be measured from a front porch so long as the porch is at least six (6) feet deep and the width is at least thirty percent (30%) of the front elevation. (Front porches meeting this standard may encroach into the front setback.) f. Front-loaded garages on residential lots less than forty-five (45) feet in width must meet this standard unless modifications are granted, pursuant to paragraph 4 below. g. The width of a side-loaded garage shall not be limited relative to the width of the lot or dwelling, if the wall of the garage facing a street includes at least two (2) windows and other features to resemble living space. The width of a driveway serving a side-loaded garage shall be limited to twenty (20) feet where it meets the property line. Side-loaded garages may also have reduced setbacks from the front property line. h. The width of a garage or driveway accessed from a rear alley shall not be limited relative to the width of the lot or dwelling. 4. Design Flexibility. a. Deviations from these standards may be approved by the Board of County Commissioners upon demonstration that other proposed design features adequately mitigate the impacts of larger garages and driveways on the neighborhood streetscape. At time of approval of a Regulating Plan and Preliminary Development Plan, the Board of County Commissioners may delegate to the Planning and Development Services Director authority to approve deviation from the standards in paragraph 3 if the Director, in his or her professional judgment, determines that the proposed alternative design is consistent with the intent to provide safe and inviting streetscapes that encourage walking and that the impact of larger driveways or garages has been adequately mitigated. b. Such alternative design options include but are not limited to: i. Commitment to provide a minimum percentage of dwellings within the neighborhood that have a one-car garage and/or a driveway that does not exceed twelve (12) feet in width; ii. Provision of structured soils or a modular suspended pavement system designed to meet the needs for water, soil and oxygen for the roots of mature street trees, while still supporting the weight of heavy vehicles. iii. Additional shade trees on individual residential lots, beyond what is required by code. iv. Wider sidewalks than what is required by code. v. Providing a Boulevard street section with shade trees and pedestrian pathways in the center median that is at least thirty (30) feet wide. vi. Second floor living space over the garage with windows overlooking the street and including Accessory Dwelling Units. vii. Brick pavers or other improved hardscape materials on the driveway. Page 432 of 456 Created: 2026-05-01 13:25:02 [EST] (Supp. No. 35) Page 9 of 24 viii. Providing two (2) separate garage doors for two-car garages rather than one (1) larger door. ix. Providing a minimum percentage of dwellings where the front-loaded garage is located in the rear of the lot and accessed by a narrow driveway. x. Providing a minimum percentage of dwellings where the garage parking is accessed from a rear alley. xi. Provide a minimum number or percentage of wider lots. G. Other Non-Residential Uses. 1. Retail and workplace land uses may be placed in a Town or Village through approval of PTV zoning (see Section 3.01.03.EE). 2. Retail and workplace land uses may also be placed outside a Town or Village when consistent with the retail standards under Objective 3.1.8 of the TVC Element or the workplace standards under Objective 3.1.10 of the TVC Element, or as necessary to achieve underlying nonresidential use intensity pursuant to Land Use Element Policies 3.1.2.5 and 3.1.3.1(4). PRW zoning (see Section 3.01.06.GG) is required except on land indicated on the Transferable Development Value Map (Figure 3-3) as suitable for industrial uses; land so indicated may also qualify for light or heavy industrial zoning districts as if the land were designated Industrial on the Future Land Use Map of the St. Lucie County Comprehensive Plan. PRW zoning is also not required for property with existing commercial zoning (CO, CN, or CG) as of August 28, 2009, but commercial development on such property must follow the development standards contained in Section 3.01.03.GG.2 and be consistent with the TVC Element. If the owner of any such existing commercially-zoned property elects to seek approval for commercial development without PRW rezoning, then the development application shall follow the submittal requirements, review procedures, and approval standards as provided for Major Site Plans under Chapter XI of this Code. (Ord. No. 11-002, § 4, 12-6-2011; Ord. No. 2020-28, Pt. A, 10-20-2020; Ord. No. 2024-014, § 2, 4-2-2024; Ord. No. 2024-28, § Pt. B(Exh. A), 8-6-2024) 4.04.05. Transferable Development Rights. A. Applicability. Section 4.04.05 establishes procedures for the Transfer of Development Rights Program for the North St. Lucie County Special Area Plan (SAP). This section establishes procedures by which transferable development rights are calculated, applied, conveyed, and recorded, for the purpose of the preservation of the County's valuable agricultural land, open space, and environmental quality, and in promoting well- designed communities, social diversity, and economic growth. Paragraph C describes how transferable development rights are assigned to land within the North St. Lucie County SAP. Paragraph D explains that landowners are under no obligation to exercise their transferable development rights and how Transferable Development Rights Credits (TDR credits) are created. The description of the qualifying sending and receiving areas are set out in paragraphs E and F herein. The use of transferable development rights, including calculation of the number of TDR credits that may be transferred is established in paragraph F. Procedures for approval of use of TDR credits are set out in paragraph G. B. Findings. St. Lucie County finds that the planning approach outlined in the Towns, Villages and Countryside (TVC) Comprehensive Plan Element promotes more efficient, predictable, and sustainable patterns of development, by encouraging new development in mixed-use Towns and Villages that reduce automobile dependency and provide greater opportunities for transit use, walking, and biking. The Town and Village developments also protect and enhance the natural environment, maintain agricultural land, and improve the citizens' quality of life. In furtherance of the Element, this section preserves and enhances existing Page 433 of 456 Created: 2026-05-01 13:25:03 [EST] (Supp. No. 35) Page 10 of 24 private property rights of small and large landowners while providing incentive-based options to landowners for new development consistent with the TVC Comprehensive Plan Element. C. Allocation of Transferable Development Rights Within the North St. Lucie County Special Area Plan (SAP). 1. Transferable development rights are afforded only to properties with residential densities consistent with Figure 3-3 of the TVC Element. Except as noted below, every parcel within the TVC Overlay Zone which is also outside of the USB, on the effective date of the TVC Element, is allocated one (1) transferable development right for each gross acre contained therein, excepting one (1) acre of the curtilage around any existing house that is designated to remain on the property. Except as noted below, every parcel within the TVC Overlay Zone which is inside the USB is allocated transferable development rights equal to the number of dwelling units allowed per acre as depicted on the Transferable Development Value Map (figure 3-3 of the TVC Comprehensive Plan Element) for each gross acre contained therein, excepting one (1) acre of the curtilage around any existing house that is designated to remain on the property. Except as noted below, parcels within the North St. Lucie SAP which are both inside the USB and designated by the County as Environmentally Significant are allocated transferable development rights equal to the number of dwelling units allowed per acre in the Future Land Use Element for each gross acre contained therein, excepting one (1) acre of the curtilage around any existing house that is designated to remain on the property. 2. Allocations for the Future Street Network. Parcels within the TVC Overlay Zone that provide right-of- way for the Future Street Network, shall not have the gross transferable development rights reduced by the accommodation of the roadway. For parcels located outside the USB less than five hundred (500) acres in size, the area donated for the right-of-way is afforded the multiplier offered in Table F-2. D. Obligation to Convey Transferable Development Rights; TDR Credits. 1. The conveyance of transferable development rights from a sending area to a receiving area is intended to occur solely on a voluntary basis between consenting landowners. Landowners are not compelled by this section to convey their transferable development rights; but if they are conveyed, the conveyance shall occur pursuant to the procedures and standards of paragraphs F and G. Transferable development rights may be severed from the sending area and conveyed by sale, donation or bequest. 2. Transferable Development Rights Credits (TDR credits) are created when a multiplier (Table F-2) is applied to the transferable development rights of a property. Each TDR credit secures one (1) additional residential dwelling unit when applied to an eligible receiving site. 3. Once transferred, TDR credits may be used to construct residential development within that receiving site without a time limitation; however, TDR credits that are not applied to that receiving area within twenty (20) years of their initial transfer shall no longer be available for transfer to another receiving area. Planned Towns or Villages (PTV) that do not use the TDR Credits generated by the Open Space and Countryside requirement within twenty (20) years of approval shall not be eligible to transfer the unused TDR Credits to another receiving site; however such credits may be used to construct residential development within the PTV without time limitation. E. The TDR Sending Area. 1. The area from which transferable development rights may be transferred is designated as the sending area, and is identified as those properties within the North St. Lucie County SAP and which are identified as desirable for conservation based on the existing natural habitat, agricultural use, location, or historic status. Sending Sites are either designated by the County as Environmentally Significant or shown on the Transferable Development Value Map (figure 3-3 of the TVC Comprehensive Plan Element, excepting one (1) acre of the curtilage around any existing house that is designated to remain after TDR transfer. The following areas may participate in the TDR Program as sending sites: Page 434 of 456 Created: 2026-05-01 13:25:03 [EST] (Supp. No. 35) Page 11 of 24 a. Areas permanently designated for the Open Space and Countryside (See Subsection H, Conditions of Conservation Easement or Deed Restriction) including land used for the following uses: i. Agricultural uses, ii. Restored or Preserved Native habitat; or Environmentally Significant Land; iii. Flow Way System; iv. Community Parks, trails, or recreation areas; v. Golf course (limited to eighteen (18) holes within a Planned Town or Village); vi. Civic Spaces within a Planned Town or Village (PTV) including neighborhood parks, greens, squares, plazas, and playgrounds provided they are publicly accessible in perpetuity; b. The following areas may also participate as sending sites (See Subsection H, Conditions of Conservation Easement or Deed Restriction): i. Parcels designated for higher education; ii. Parcels designated for targeted industry; iii Additional Building Lots designated for workforce housing above the requirement for eight percent (8%) of the proposed number dwellings in a PTV (See Section 3.01.03.EE.2.q); iv. Civic Building Lots including schools, police stations, houses of worship; v. Parcels containing sites of archaeological or historical significance (See Subsection I, Conditions of Deed Restriction); vi. For parcels less than five hundred (500) acres, land donated as right-of-way for the Regional Street Network. Parcels greater than five hundred (500) acres may not count land used as right-of-way for the Future Street Network as Open Space and Countryside or use a multiplier on the underlying transferable development rights. 2. The properties within the North St. Lucie County SAP include two (2) distinct areas: (a) lands outside of the Urban Service Boundary, and (b) lands within the Urban Service Boundary. a. Outside of the USB, TDR credits may be sent from any one (1) property to another providing the receiving site is a minimum of five hundred (500) acres in size. b. Outside the USB, TDR credits may be sent from any one (1) property, to any property within the USB providing the receiving site is within the TVC Overlay Zone or is designated on the North St. Lucie County Preferred TDR Receiving Site Map (Figure 3-12 of the TVC Comprehensive Plan Element). c. Inside the USB, within the TVC Overlay Zone, TDR credits may be sent from any one (1) property to another. d. TDR Credits may not be sent from a property within the USB to a property outside of the USB, except if (1) the sending property is both within the North St. Lucie County SAP and is designated by the County as Environmentally Significant or (2) the property is contiguous (parcels are adjoining for a minimum of ¼ mile) and partially located both inside the USB and outside USB but wholly located within the TVC Overlay Zone. 3. In addition, the following limitations apply for parcelsof less than five hundred (500) acres located outside of the USB: a. A parcel of less than five hundred (500) acres located outside the Urban Service Boundary may not be developed at a higher density, including by the use of TDR Credits generated on-site or Page 435 of 456 Created: 2026-05-01 13:25:03 [EST] (Supp. No. 35) Page 12 of 24 acquired from off-site locations, than that allowed by the density permitted by the Transferable Development Value Map (figure 3-3 of the TVC Element), unless a landowner of less than five hundred (500) acres enters into an agreement with one (1) or more adjoining landowners to develop five hundred (500) or more acres into a Town or Village pursuant to these land development regulations. b. Properties of less than five hundred (500) acres located outside of the USB may be subdivided into individual home sites equal to or less than the number of lots permitted by the Transferable Development Value Map (figure 3-3 of the TVC Element), however, any unused transferable development rights are not eligible for participation in the TDR Program. c. Transferable development rights on properties of less than five hundred (500) acres located outside of the USB may be transferred but only (i) in a minimum amount of ninety percent (90%) of the total transferable development rights on the property; and (ii) to an eligible receiving site within the North St. Lucie County SAP. Once a minimum of ninety percent (90%) of the transferable development rights is transferred or designated for future transfer pursuant to the process outlined in Subsection H, the sending property may then be subdivided into individual home sites up to the number of lots permitted by the remaining development rights. Such home sites are eligible to receive urban services only at the property owner's expense. Parcels of at least 1.5 acres and under ten (10) acres may transfer development rights provided only one (1) transferable development right remains on the parcel and all others are transferred or designated for future transfer. 4. Parcels of five hundred (500) or more acres located outside of USB and parcels of one hundred ten (110) or more acres located inside the USB may use the TDR Program to increase density to create a Village or Town, pursuant to these land development regulations. Landowners may act as both transferor and transferee of the TDR Credits and may apply TDR credits generated on site to developing the Net Developable Area of the Town or Village. In addition, the following limitations apply: a. Landowners who own five hundred (500) or more contiguous acres outside the USB in the TVC Overlay Zone may not subdivide the property into individual home sites according to the underlying base zone. b. Subdividing parcels of five hundred (500) or more acres located outside the USB for the express purpose of avoiding the regulations of the TVC Overlay Zone is prohibited. 5. Parcels inside the USB that opt to develop in accordance with a planned zoning district other than a PTV (See Section 4.04.04.E(1)(b)) may not participate in the TDR Program as sending sites for either internal or off-site transferable development right transfers. F. The Use of Transferable Development Rights Within the Receiving Area. 1. The area to which TDR credits may be transferred is the receiving area. Eligible receiving sites must be located within the North St. Lucie County SAP and include the following: a. Sites inside the Urban Service Boundary that are (i) designated on the North St. Lucie County Preferred TDR Receiving Sites Map (Comprehensive Plan Figure 11-12 of the TVC Element) or (ii) located within the TVC Overlay Zone; or b. Sites located outside the Urban Service Boundary, of five hundred (500) or more acres in size, on which there is County approval to build a Town or a Village or a Hamlet PUD. In such case, however, TDR credits sent from inside the USB may only be from lands designated as Environmentally Significant by the County, unless the land is contiguous. In addition, the transferable development rights assigned to properties of five hundred (500) or more acres may be used to develop the site as a Town or Village or a Hamlet PUD pursuant to this Section. Page 436 of 456 Created: 2026-05-01 13:25:03 [EST] (Supp. No. 35) Page 13 of 24 2. Consolidation of Property. A parcel of five hundred (500) or more acres outside the USB or one hundred ten (110) acres or more inside the USB in the TVC Overlay Zone may be developed as a Town or Village through the use of transferable development rights. Land area of five hundred (500) acres or more outside the USB may be developed as a Hamlet using transferable development rights. If a landowner completes a Town, Village and owns remaining land not associated with the Town or Village, the transferable development rights from that remaining land may be sold to another landowner or the land may be consolidated with other properties to form the minimum size required to create another Town, Village using transferable development rights pursuant to this Section. Separately owned, noncontiguous parcels of less than the minimum size of a Town or Village in the TVC Overlay Zone may be consolidated to create a Town or Village. Noncontiguous parcels may be consolidated to form a Hamlet, provided, at least one (1) of the parcels is at least two hundred fifty (250) acres and all parcels proposed for inclusion in a Hamlet are located within one thousand five hundred (1,500) feet of the primary development parcel. Hamlets utilizing noncontiguous parcels shall prioritize countryside (preservation or restoration of native habitat, perpetual agricultural uses, other open space) on the outlying parcels while ensuring compatibility of density, design and transition with surrounding land uses. 3. Calculation of Transferable Development Rights Credits. The number of TDR credits that can be transferred from an eligible sending site to an eligible receiving site is calculated by (a) on the sending site, multiplying the acreage and the dwelling units per acre allowed on the Transferable Development Value Map (figure 3-3 of the TVC Element), then subtracting the number of existing dwellings designated to remain on the site and (b) multiplying the resulting sum by the applicable multiplier on Table F-2 to yield the total number of TDR credits. (See Table F-1 as an example). Table F-1. Example A: Outside the Urban Service Boundary - Transferable Development Rights Credits Sent From a Parcel Outside the Urban Service Boundary of Less than five hundred (500) Acres to Another Parcel Parcel Size 20 acres Transferable Development Rights (Base Zone) from TDV 1 dwelling unit per acre Number of Existing Dwellings 1 Total Transferable Development Rights From Sending Site 20 acres x 1 du/ac = 20 dwelling units 20 dwellings - 1 dwelling = 19 dwelling units Multiplier from Table F-2 2 Calculation of TDR Credits for Use on Receiving Site 19 dwelling units x 2 = 38 TDR Credits Table F-2 indicates the multiplier that is applicable to the appropriate transfer condition, and used to multiply the allowable base zone density of the sending area. For parcels that have more than one (1) transfer condition as described in Table F-2, the multipliers for the corresponding portions of the site shall be applied. The resulting sums shall be added together to compute the total TDR Credits for the sending site (see the example in Table F-3). Table F-2. TVC Transferable Development Right Credit Multipliers Transfer Condition Multiplier From Countryside in a Village located Outside the Urban Service Boundary to an Eligible Receiving Site located Outside the Urban Service Boundary. 1.25 From Countryside in a Town located Outside the Urban Service Boundary to an Eligible Receiving Site located Outside the Urban Service Boundary. 1.5 Page 437 of 456 Created: 2026-05-01 13:25:03 [EST] (Supp. No. 35) Page 14 of 24 From Countryside in a Town or Village located Inside the Urban Service Boundary to an Eligible Receiving Site located Inside the Urban Service Boundary. 1.75 From Countryside of a Town located on Contiguous Property both Inside and Outside of the Urban Service Boundary to the Net Developable Area. 1.75 From Countryside located Outside the Urban Service Boundary to an Eligible Receiving Site Inside the Urban Service Boundary. 2 From a Parcel Less than 500 acres in size Outside the Urban Service Boundary to an Eligible Receiving Site Inside or Outside the Urban Service Boundary. 2 From Targeted Industry Site to an Eligible Receiving Site. 2.5 From Higher Education Site to an Eligible Receiving Site. 2.5 From Agricultural Research and Education Facilities to an Eligible Receiving Site. 2.5 From Created or Preserved Native Habitat in the Countryside to an Eligible Receiving Site. 2.5 From Environmentally Significant Land to an Eligible Receiving Site. 2.5 From Countryside to a Workforce Housing Unit 2.5 4. The number of dwelling units available in the Net Developable area of a PTV is established by (1) multiplying the gross acres in the net developable area by the density permitted by the Transferable Development Value Map (figure 3-3 of the TVC Element) then, (2) adding TDR Credits available from both internal and external sending sites. The total number of dwelling units available in the proposed Town or Village, is the sum of the number of TDR credits (as established in Subsection 3. above) and the number of dwelling units permitted in the Net Developable Area. Example B. The owner of a five-hundred-acre parcel located outside of the Urban Service Boundary proposes to build a new Village development. At least seventy-five percent (75%) of the site must be set aside as Open Space and Countryside. The net development density must result in at least six hundred twenty-five (625) dwelling units, and at least fifty (50) units (eight percent (8%)) must be Workforce Housing units. Transferable development rights moved from the Countryside for use as Workforce Housing receives a multiplier of 2.5. The remaining land set aside for Countryside receives a multiplier of 1.25. The TDR credits and total dwelling units for the Village are shown in Table F-3. Table F-3. Parcel Size 500 acres Net Developable Area 125 acres Minimum Number of Units Required 625 dwelling units Open Space and Countryside Provided 375 acres Minimum Workforce Units Required Workforce Dwelling Units Proposed 50 dwelling units 53 dwelling units Density permitted by the Transferable Development Value Map 1 dwelling unit per acre Transferable Development Rights 375 acres x 1 dwelling unit per acre = 375 dwelling units Multiplier for Workforce Dwelling Units 2.5 Multiplier for Open Space and Countryside 1.25 Calculation of TDR Credits for Workforce Units 53 dwelling units x 2.5 = 132.5 or 133 TDR credits Calculation of TDR Credits for Countryside 375 dwelling units-53 Workforce dwelling units = 322 dwelling units 322 dwelling units x 1.25 = 402.5 or 403 TDR credits Page 438 of 456 Created: 2026-05-01 13:25:03 [EST] (Supp. No. 35) Page 15 of 24 Dwelling units available in the Net Developable Area 125 acres at 1 dwelling unit per acre = 125 dwelling units Total Dwelling Units Generated for Village 125 dwelling units + 133 TDR credits + 403 TDR credits = 661 dwelling units Example C. The owner of a one-thousand-acre parcel located outside of the Urban Service Boundary proposes to build a new Town development. At least sixty percent (60%) of the site must be set aside as Open Space and Countryside. The net development density must result in at least two thousand (2,000) dwelling units, and at least one hundred sixty (160) units (eight percent (8%)) must be Workforce Housing units. Transferable development rights moved from the Countryside for use as Workforce Housing receives a multiplier of 2.5. The remaining land set aside for Countryside receives a multiplier of 1.5. The TDR credits and total dwelling units for the Town are shown in Table F-4. Table F-4. Example C: Transferable Development Rights Transferred within a Parcel of one thousand (1,000) acres Outside of the Urban Service Boundary Parcel Size 1,000 acres Net Developable Area 400 acres Minimum Number of Units Required 2,000 dwelling units Minimum Open Space and Countryside Required 600 acres Workforce Dwelling Units Proposed 160 dwelling units Density of Underlying Base Zone 1 dwelling unit per acre Transferable Development Rights 600 acres x 1 dwelling unit per acre = 600 dwelling units Multiplier for Workforce Dwelling Units 2.5 Multiplier for Open Space and Countryside 1.5 Calculation of TDR Credits for Workforce Units 160 du x 2.5 = 400 credits Calculation of TDR Credits for Countryside 600 du - 160 du = 440 du 440 du x 1.5 = 660 credits Total TDR Credits 1060 credits Dwelling units in base zone of Net Developable Area 400 ac x 1 du/ac = 400 du Total Dwelling Units Generated for Town 1,060 transferable development credits + 400 du = 1,460 du This is less than the 2,000 units required. Note for Example C: Five hundred forty (540) additional TDR credits are needed to meet the minimum density required to build a town. Credits can be acquired or generated through various methods in the TDR Program. G. Procedures for Use of Transferable Development Rights Credits. The use of TDR credits must comply with the following procedures. 1. The owner of the sending site (the "transferor") and the owner of the receiving site (the "transferee") shall submit a signed application on a form provided by the St. Lucie County Planning Department. Along with the application form, the following shall be submitted: a. A legal description of the sending site. b. A plot plan or survey, showing total acreage of the sending site, and that property within the sending site that is subject to any easement or restrictions against development, and one (1) acre of the curtilage around any existing house that is intended to remain. Page 439 of 456 Created: 2026-05-01 13:25:03 [EST] (Supp. No. 35) Page 16 of 24 c. For parcels proposing to build a Town or Village, in addition to the requirements for the PTV, a plan that clearly indicates the total acreage of the parcel, the amount of acreage in each category of the Transferable Development Value Map (figure 3-3 of the TVC Element), the portion of the parcel from which development rights are to be transferred, the multiplier identified for each transferable development right, the appropriate conservation easement or deed restriction for the sending area; the total TDR credits and number of dwelling units. d. For those parcels less than five hundred (500) acres located outside of the USB that seek to transfer a minimum of ninety percent (90%) of the transferable development rights from the property, a plan that (1) notes the transferable development rights attributed to the entire parcel, (2) identifies the number of transferable development rights proposed to remain on the site, (3) identifies the proposed multiplier, (4) calculates the number of TDR credits available for transfer. e. A title search of the sending site sufficient to determine all owners of the site and all lien holders. Title insurance shall be required for any sending site on which a Conservation Easement or Deed Restriction is recorded. f. A copy of the proposed Deed of Transferable Development Rights Credits and a copy of the proposed Conservation Easement or Deed Restriction. g. An Agreement of Conveyance for the development rights between the owner of the development rights to be transferred and the purchaser of the transferable development rights. The agreement may be contingent upon approval of a final subdivision plan for the receiving property. h. Proof of previously severed transferable development rights, if the transferee proposes to use transferable development rights which were previously severed from a tract in the sending area. 2. The Growth Management Director shall review the application and determine if it is complete. If the application is complete, the Director shall issue a Certificate of Filing to the applicants. 3. Review and Approval for Conveyance of Transferable Development Rights. a. Upon receiving a complete application, as required above, the Growth Management Director shall determine the number of transferable development rights which can be conveyed from the sending tract. The Growth Management Director shall also determine, with the advice of the County Attorney and County Engineer, the sufficiency of (1) the Conservation Easement or Deed Restriction, and (2) the Deed of Transferable Development Rights. The Growth Management Director's determination shall be provided to the applicants in a written Preliminary Certification of Transferable Development Rights Credits. A final Certification of Transferable Development Rights Credits shall be approved by the County Commissioners and recorded with the Clerk of the Circuit Court along with the approved Conservation Easement. b. Any appeals of the Preliminary Certification of Transferable Development Rights Credits shall be made in accordance with the provisions of Section 11.11.00 of this Code. c. For proposed developments that rely upon transferable development rights to increase permitted dwelling units per acre beyond that of the base permitted density, no building permit shall be issued until the County has been presented with a copy of the recorded Deed of Transferable Development Rights and a copy of the recorded Conservation Easement. The entity responsible for the administration, management, and maintenance of the land set aside for the Open Space and Countryside of each new Town or Village shall be identified as part of the subdivision approval. Page 440 of 456 Created: 2026-05-01 13:25:03 [EST] (Supp. No. 35) Page 17 of 24 d. St. Lucie County shall not approve the Deed of Transferable Development Rights Credits or issue a Final Certification of Transferable Development Rights Credits until the County has received evidence that the Conservation Easement or Deed Restriction has been duly signed by all relevant parties and recorded with the Clerk of the Circuit Court. e. A transferee acquiring transferable development rights may donate or sell all or part of the required Open Space and Countryside associated with a Town or Village to St. Lucie County or to either a duly qualified conservancy or land trust that has received a 501(c)(3) designation from the Internal Revenue Service. The conservancy or land trust must be approved by the County. H. Conditions of the Conservation Easement or Deed Restriction. 1. The owner conveying transferable development rights shall perpetually restrict the use of the sending site by a Conservation Easement or Deed Restriction. The Conservation Easement or Deed Restriction shall be in a form approved by the St. Lucie County Attorney. The Conservation Easement shall be used to restrict future use of the Open Space and Countryside to the following: a. Agricultural uses; b. Restored or Preserved Native habitat; or Environmentally Significant Land; c. Flow Way System; d. Community Parks, trails, or recreation areas; e. Golf course (limited to eighteen (18) holes within a Town or Village); f. Civic Spaces within a PTV including neighborhood parks, greens, squares, plazas, and playgrounds provided they are publicly accessible in perpetuity. The Deed Restriction shall be used to restrict the use of the parcel to the following: a. A limited number of dwelling units; b. Higher education; c. Targeted industry; d. Building Lots designated for workforce housing; e. Civic Building Lots including schools, police stations, houses of worship; f. Parcels containing sites of archaeological or historical significance. 2. The Conservation Easement shall also reference and include a land and water management plan. 3. Any Conservation Easement shall designate, as a third party beneficiary of the restrictions imposed upon the sending property, St. Lucie County, a Conservancy approved by St. Lucie County, or a land trust that has received a designation of 501(c)(3) status from the Internal Revenue Service and approved by St. Lucie County. Such restrictions shall be enforceable by the County as a third party beneficiary. 4. If less than all of the transferable development rights are to be conveyed from the parcel, the remaining number of transferable development rights shall be recorded by Deed Restriction acceptable to the County Attorney. All owners of the tracts from which transferable development rights are conveyed shall execute the Deed Restriction or Conservation Easement. All lien holders of the tract from which transferable development rights are conveyed shall execute a Subordination Agreement to the Conservation Easement. The Subordination Agreement shall be recorded with the Clerk of the Circuit Court. All owners of the sending site shall also provide title insurance. Page 441 of 456 Created: 2026-05-01 13:25:03 [EST] (Supp. No. 35) Page 18 of 24 I. Requirements of Open Space and Countryside Associated with Towns or Villages Created through the Transfer of Development Rights. 1. The owner applying transferable development rights to the development of a Town or Village shall perpetually restrict the associated Open Space and Countryside by a Conservation Easement or Deed Restriction. The Conservation Easement or Deed Restriction shall be in a form approved by the St. Lucie County Attorney. The Conservation Easement shall be used to restrict future use of the Open Space and Countryside to the following: a. Agricultural uses; b. Restored or Preserved Native habitat; or Environmentally Significant Land; c. Flow Way System; d. Community Parks, trails, or recreation areas; e. Golf course (limited to eighteen (18) holes within a Town or Village); f. Civic Spaces within a PTV including neighborhood parks, greens, squares, plazas, and playgrounds provided they are publicly accessible in perpetuity. The Deed Restriction shall be used to restrict future use of the parcel to the following: a. Higher education; b. Targeted industry; c. Building Lots designated for workforce housing; d. Civic Building Lots including schools, police stations, houses of worship; e. Parcels containing sites of archaeological or historical significance. 2. The Conservation Easement shall also reference and include a land and water management plan for the Open Space and Countryside portion of the Town or Village. J. Value of Transferable Development Rights. The monetary value of Transferable Development Rights is determined between buyer and seller. K. Public Acquisition of Transferable Development Rights. The County Commission may purchase development rights and may accept ownership of transferable development rights through gift. Any such purchase or gift shall be accompanied by a Conservation Easement or Deed Restriction, as specified in Subsection H of this Ordinance. The County may re-sell, subject to the time limitation in Subsection D, or retire any transferable development rights credits it has acquired. L. Definitions. The following definitions shall apply to this Section 4.04.05. Agricultural Research and Education Facilities: The agricultural uses and the associated facilities including green houses, laboratories and field offices related to agricultural research activities such as, but not limited to USDA, the Institute of Food and Agriculture Sciences (IFAS), the St. Lucie Agricultural Research and Education Park and Harbor Branch Oceanographic Institute. Certificate of Filing: A document issued by the St. Lucie County to an applicant for a development project indicating that a full and complete application has been submitted. Conservation Easement: A legal document filed in the County's official property records, placing limits on the use of a property. A deed restriction within the TVC extinguishes the right to build homes on or subdivide residential lots from a sending property but allows other uses, such as agriculture, drainage, low intensity recreation, and those described in the TVC element as possible uses for the countryside and open space. Page 442 of 456 Created: 2026-05-01 13:25:03 [EST] (Supp. No. 35) Page 19 of 24 Deed Restriction: A legal document filed in the County's official property records, placing limits on the use of a property. A deed restriction within the TVC required by this Section reduces the right to build homes on or subdivide residential lots from a sending property or may restrict the property to specific uses such as higher education, workforce housing, and those uses described in the TVC Element as possible uses for the countryside and open space. Density: The number of dwellings that can be placed on a unit of land. Density is expressed as the number of dwelling units per acre of land. Development Rights: The maximum amount of residential development that would be permitted on a parcel of land under the applicable zoning and subdivision regulations. Development rights are expressed as the maximum number of dwelling units per acre. Dwelling Unit: A dwelling unit as defined in the TVC Overlay Zoning District may consist of a single-family detached house, a single-family attached house, a condominium, or an apartment. Encumber: The act of burdening a transferable development right with a financial liability, such as pledging a transferable development right as security or collateral for a loan. Receiving site: A parcel of land located within the Special Area Plan, to which development rights may be transferred. Redeem: The act of using transferable development rights to obtain density bonuses on receiving properties. Once redeemed, transferable development rights can never be used again. Sending site: A parcel of land located within the Special Area Plan (SAP) from which development rights may be transferred. Severed: The act of officially separating and retiring transferable development rights from sending properties. This occurs after a conservation easement or deed restriction is recorded. Title Search: A report issued by a title insurance or abstract company. In the Transfer of Development Rights program, it ensures that landowners have a legal right to place a deed restriction on their properties. Transferable Development Rights Certificate: A document issued by St. Lucie County which attests to the fact that transferable development rights are available for sale or use. It identifies the number of transferable development rights, the current owner, and the originating parcel of land from which the transferable development rights were severed. The certificate also includes sections that must be completed whenever the transferable development rights are sold, transferred, encumbered, or redeemed. (Ord. No. 2024-28, § Pt. B(Exh. A), 8-6-2024) 4.04.06. Definitions. When used in Section 4.04 and Sections 3.01.03.EE through GG of this Code, the following terms shall have the meanings ascribed to them. Terms defined in Chapter II of this Code shall those same meanings. Accessory Dwelling: One (1) ancillary building that may contain an independent dwelling unit, limited in size, sharing ownership and utility connections with a principal building on the same lot, typically located in the rear of the lot. Affordable: Monthly rents or mortgage payments, including taxes, insurance, and utilities do not exceed thirty percent (30%) of the monthly income of the family. Affordable Housing: Rental or for-sale housing that is affordable to people earning fifty percent (50%) to eighty percent (80%) of Area Median Income. Agriculture: Farming: the cultivation of soil, production of crops, or raising of livestock. Page 443 of 456 Created: 2026-05-01 13:25:03 [EST] (Supp. No. 35) Page 20 of 24 Arcade: A series of piers topped by arches that support a permanent roof over a sidewalk. Average Density: The average number of dwelling units per acre within the Net Developable Area. This number is an average to allow denser development in the Core and Center transect zones with development becoming less dense through the General and Edge zones. Balcony: An open portion of an upper floor extending beyond a building's exterior wall that is not supported from below by vertical columns or piers. Building Frontage: The percentage of the total width of a lot which is required to be building wall, measured where the front yard ends and the front of the building begins. Center: One (1) of the four (4) neighborhood zones that make up a cross-section or transect of a Town or Village. The Center transect zone is the second most intensely occupied zone in a neighborhood, with a wide range of uses in detached and attached buildings. See Section 4.04.02.B. Civic Building: Civic buildings contain uses of special public importance. Civic buildings include, but are not limited to, municipal buildings, churches, libraries, schools, day care centers, recreation facilities, and places of assembly. Civic buildings do not include retail buildings, residential buildings, or buildings with private offices. Civic Space: Civic spaces are open areas dedicated for public use. Typical civic spaces include neighborhood parks, greens, squares, plazas, and playgrounds. Civic Use: The use of land or buildings by not-for-profit organizations primarily for governmental, educational, artistic, cultural, social, or religious purposes. Civic uses may be outdoors (in civic spaces), in civic buildings, or in buildings with other uses. Close: A small green area surrounded by a driveway that provides vehicular access to several buildings and performs the same function as a cul-de-sac. Colonnade: Similar to an arcade except that it is supported by vertical columns without arches. Community Development District (CDD): A unit of the government classified as an independent special district governed by a board composed of landowners within the district. A CDD is created pursuant to Florida Statutes and has the power to assess ad valorem taxes upon the lands in the district and special assessments in order to provide services required to develop the land, such as road building, water and sewer facilities, drainage, conservation and mitigation areas, parks, and other recreational facilities. Community Stewardship Organization (CSO): Not-for-profit organization dedicated to education and conservation efforts that benefit both development and the community. Convenience Center: A collection of small stores servicing a range of daily needs from dry cleaning to baked goods, ranging between three thousand (3,000) and eighty thousand (80,000) square feet in size, located along an important thoroughfare, between two (2) neighborhoods, serving the daily needs of two (2) to three (3) neighborhoods. Core: One (1) of the four (4) neighborhood zones that make up a cross-section or transect of a Town or Village. The Core transect zone is the most intensely occupied zone in a neighborhood, with mostly attached buildings that create a continuous street facade within walking distance of surrounding residential areas. See Section 4.04.02.B. Countryside: Land, including natural habitat, agriculture, community recreation areas and similar uses, required to be set aside as open and unobstructed to the sky in perpetuity, but not including rights-of-way dedicated for streets, roads, or alleys. For purposes of this Code, the Countryside is divided into two (2) transect zones, the Fringe zone which adjoins neighborhoods or other public spaces and Rural zone which does not adjoin neighborhoods. Page 444 of 456 Created: 2026-05-01 13:25:03 [EST] (Supp. No. 35) Page 21 of 24 Countryside Uses: Land in the Countryside as defined in this Code may be used only for purposes described in Section 3.01.03.EE.2.o. Edge: One (1) of the four (4) neighborhood zones that make up a cross-section or transect of a Town or Village. The Edge transect zone has larger lots for detached homes and provides a physical change between the remainder of the neighborhood and the adjoining countryside. See Section 4.04.02.B. Environmentally Significant Land: Land identified as Environmentally Significant and/or ranked as A, B or C on the County's Native Habitat Inventory Map, as those may change from time to time. Flow Way System: The land and water areas that together will comprise a continuous water management system for the TVC area. This system will provide water storage and attenuation to manage stormwater before it discharges into the Indian River Lagoon. This regional system will be created incrementally as it expands, supplements, or modifies the existing canal network in order to restore more natural discharge patterns. Fringe: One (1) of the two (2) countryside zones that make up a cross-section or transect of a Town or Village. The Fringe transect zone is the first layer of the Countryside that provides a harmonious transition between neighborhoods and the Rural transect zone. See Section 4.04.02.B. General: One (1) of the four (4) neighborhood zones that make up a cross-section or transect of a Town or Village. The General transect zone is usually the largest part of a neighborhood with a mix of detached homes and some multifamily buildings, typically separated from the street with front yards. See Section 4.04.02.B. Greenway: A narrow or wide corridor of open space managed for natural resource conservation and/or recreation. Higher Education: Education institutions operated by the state university system, state department of education, or private accredited institutions providing post-secondary, vocational, or other specialized forms of learning. Highway Service Retail: Vehicular-oriented retail such as gas stations, motels, and fast food restaurants. Lane: A right-of-way for service access to the back of properties, similar to an alley but less urban in character. Liner Building: A building or portion of a building constructed in front of a parking garage, cinema, supermarket etc., to conceal large expanses of blank wall area and to face the street space with a facade that has ample doors and windows opening onto the sidewalk. Live/Work Building: An attached building that can accommodate residential use, business use, or a combination of the two (2) within individually occupied units. These uses may occur on any story of a live/work building. Local Store: Typically a single proprietor establishment, the average size is five hundred (500) to two thousand (2,000) square feet. Local stores are located in either the within or along the edge of a neighborhood and typically serve one (1) neighborhood. Either residential or office uses are appropriate above the ground level retail. Local stores are not expected to expand in size over time. Mixed-Use: Combining two (2) or more of the following uses: retail, commercial, and residential within the same building or on the same site. Mixed-Use Business District: An area that due to its location has the development potential to specialize in terms of accommodating significant business functions. A Mixed-Use Business District should include a variety of uses and is encouraged to provide a place for office complexes that would not be compatible in neighborhoods. Land located within the Mixed-Use Business District may also develop pursuant to the density and intensity established by the Transferable Development Value Map (Figure 3-3 of the St. Lucie County Comprehensive Plan) and otherwise in accordance with the Goals, Objectives and Policies of the TVC Element. Mixed-Use Business Page 445 of 456 Created: 2026-05-01 13:25:03 [EST] (Supp. No. 35) Page 22 of 24 Districts are depicted on the North St. Lucie County General Workplace Plan (Figure 3-16 and Objective 3.1.10 of the St. Lucie County Comprehensive Plan). Neighborhood: The basic building block of all new development within the TVC, generally ranging in size from eighty (80) to one hundred fifty (150) acres (not including land set aside for the Countryside component), scaled upon a radius of approximately one-quarter-mile and containing a mix of uses that include residential, retail, office, civic and recreation spaces to support the daily needs of its residents within walking/bicycling/wheelchair distance. Neighborhood Center: Larger than a Convenience Center, the Neighborhood Center averages one hundred thousand (100,000) square feet in size and is anchored with a grocery store. The Neighborhood Center is located at the intersection of two (2) important roads and serves the daily needs of three (3) to four (4) neighborhoods. Net Developable Area: The land area remaining for neighborhood development once the acreage requirement for Countryside has been achieved (see Section 3.01.03.EE.2.b). Open Space: Land that is dedicated to Countryside including natural habitat, agriculture, and recreational parks, or used to fulfill other county objectives (see TVC Element Policy 3.1.5.4). Planting Strip: Grassy strip of land that accommodates rows of street trees, usually located between the edge of a travel lane and the sidewalk. In urban areas, the planting strip often consists of trees planted in tree wells recessed into the sidewalk rather than planted on a grassy strip. Porch: An elevated, roofed, and unwalled platform on the facade of a building. Porches are supported from below by vertical columns or piers, and have sufficient depth to allow outdoor seating without interfering with any entry functions of the porch. Porte Cochere: A roofed porch or portico-like structure extending from the side entrance of a building over an adjacent driveway to shelter those getting in or out of vehicles. A porte cochere differs from a carport in that it is not used to cover parked vehicles. Regulating Plan: A type of site plan or a supplement to a site plan for a proposed development in the TVC Overlay that must be submitted to St. Lucie County under certain conditions. A regulating plan identifies proposed transect zones, lot types, and street types. A regulating plan defines the character of the proposed development and, if approved, becomes an integral part of the development approval. See Section 3.01.03.EE.3. Rural: One (1) of the two (2) countryside zones that make up a cross-section or transect of a Town or Village. The Rural transect zone is further from neighborhoods and contains the full range of permitted agricultural, recreational, and open space uses. See Section 4.04.02.B. Settlement Principles: The guidelines for development established in Policy 3.1.4.2 of the St. Lucie County Comprehensive Plan. Specialized District: A transect zone that accommodates development types or forms that are not fully integrated with adjoining neighborhoods. See Section 3.01.03.GG. Stoop: A staircase on the facade of a building, usually constructed of concrete or stone, that leads either to a small unwalled entrance platform or directly to the main entry door. Story: That portion of a building or structure included between the upper surface of a floor and the lower surface of the ceiling or exposed roof next above. Each mezzanine that exceeds the percentage of floor area for a mezzanine defined in the Florida Building Code is counted as a story for the purposes of measuring height. Each story used exclusively for parking vehicles is also counted as a story. Space within a roofline that is entirely non- habitable shall not be considered to be a story. Targeted Industry: Businesses identified by the St. Lucie County Growth Management Department in conjunction with the Economic Development Council as desirable to promote job growth in the County. Such businesses are set forth every two (2) years as eligible for the Job Growth Investment Grant Program and include a Page 446 of 456 Created: 2026-05-01 13:25:03 [EST] (Supp. No. 35) Page 23 of 24 wide range of commerce; approval by the Board of County Commissioners is required when proposed in the TVC area. See Section 3.01.03.EE.2.r. TDR Credits: Credits that are created when the unused transferable development rights of a property receive a multiplier. One (1) credit may be eligible to secure one (1) additional dwelling unit of density when applied to a qualified development. Town: Two (2) or more neighborhoods in the Countryside. Town Center: Town Centers are an open-air collection of core retailers, typically a minimum of two hundred thousand (200,000) square feet, serving approximately twenty-five thousand (25,000) persons with a primary trade area of six (6) to ten (10) miles. Tenants include multiple anchors, shops, movie theaters, a grocery store, department store, bookseller, restaurants, boutiques, residential units and possibly a hotel. A Town Center distinguishes itself from conventional open-air centers by including a variety of residential types, office and civic uses. The Town Center could ultimately evolve into areas served by mass transit with higher densities. Appropriate locations are along major thoroughfares close to an interstate interchange or within downtown areas. Transect Zone: A distinct category of physical form ranging from the most urban to the most rural of human habitats. This code defines four (4) neighborhood transect zones: Core, Center, General, and Edge; two (2) Countryside transect zones: Fringe and Rural; and a Specialized District transect zone. See Sections 4.04.02.B and 3.01.03.GG. Transferable Development Value: The density and intensity designated on a property by the Transferable Development Value Map. Transitional Areas: A defined area near St. Lucie Boulevard and Kings Highway as shown on the North St. Lucie County General Workplace Plan (Figure 3-16 and Objective 3.1.10 of the St. Lucie County Comprehensive Plan). TVC Element: The Towns, Villages and Countryside Element of the St. Lucie County Comprehensive Plan. TVC Overlay Zone: See Section 4.04.02. Urban Services: Potable water supply and distribution; sanitary sewer collection, treatment, and disposal. Village: One (1) neighborhood in the Countryside. Village Center: A Village Center is eighty thousand (80,000) to one hundred forty thousand (140,000) square feet and has tenants similar to those in a Neighborhood Center and may include hotels or motels. Village Centers are located at an intersection of two (2) important thoroughfares and serve four (4) to five (5) adjacent neighborhoods. Warehouse Type: Often associated with discount or home improvement retail, typically located along heavily traveled roads or rail corridors. Workforce Housing: Housing that is affordable to families earning from eighty percent (80%) to one hundred twenty percent (120%) of the Area Median Income. Area Median Income is based on the most recent figures for the Port St. Lucie-Fort Pierce Metropolitan Statistical Area as reported annually by the United States Department of Housing and Urban Development. Area Median Income data is available from the St. Lucie County Department of Growth Management. 4.04.07 Performance Monitoring. St. Lucie County will monitor and evaluate the performance of the TVC Element of the Comprehensive Plan, including the performance of these implementing regulations, to include at least the following performance measures: A. Development Plans in TVC Overlay: Page 447 of 456 Created: 2026-05-01 13:25:03 [EST] (Supp. No. 35) Page 24 of 24 1. Acres of land rezoned to PTV, PCS, and PRW 2. Acres of land rezoned to other zoning districts 3. Net developable area of each approved Town and Village 4. Number of proposed residential units in each approved Town and Village 5. Number of proposed residential units that were approved as workforce housing B. Open Space and Countryside: 1. Acres of land designated as Countryside 2. Mapping of Countryside acreage to illustrate its size and contiguity 3. Acres of land credited as Open Space components through PTV zoning 4. Acres of land designated for the Flow Way System through PTV zoning 5. Mapping of Flow Way System acreage to illustrate its contiguity and its relationship to existing drainage canals C. Transferable Development Credits: 1. Acres of land from which residential development rights have been transferred; 2. Number of TDR credits that have been created; 3. Number of TDR credits that have been applied to construct residential units. D. Future Street Network: 1. Mapping of street network overlaid on conceptual TVC Street Network for 2030 (see Figure 4-12) Page 448 of 456 Page 449 of 456 Page 450 of 456 Page 451 of 456 Page 452 of 456 ST. LUCIE COUNTY PLANNING AND ZONING COMMISSION PUBLIC HEARING AGENDA THURSDAY, July 16, 2026 The St. Lucie County Planning and Zoning Commission is scheduled to review and make recommendations to the Board of County Commissioners regarding the following proposed Resolutions: RESOLUTION I A RESOLUTION OF THE BOARD OF COUNTY COMMISSIONERS OF ST. LUCIE COUNTY, FLORIDA, AMENDING THE OFFICIAL ZONING ATLAS FROM THE AR-1 (AGRICULTURAL RESIDENTIAL -1) ZONING DISTRICT TO THE PNRD (PLANNED NON-RESIDENTIAL DEVELOPMENT) ZONING DISTRICT AND APPROVING A PRELIMINARY DEVELOPMENT PLAN ON +/-159 ACRES Property Owners: St. Lucie County PCC2023, LLC 2300 Virginia Avenue 108 Talavera Place Fort Pierce, FL 34942 Palm Beach Gardens, FL 33418 Applicant: Ashley Capital, LLC 9810 S. Dorchester Ave. Chicago, IL 60628 Location: West side of S. Kings Highway, north and south of Picos Road Parcel ID Numbers: 2314-111-0004-000-9; 2314-120-0000-000-9; 2314-131-0000-000-3; & 2314-800-0002-000-0 PURPOSE: Proposed amendment of the Official Zoning Atlas to change the AR-1 (Agricultural Residential -1) Zoning District to the PNRD (Planned Non-Residential Development) Zoning District and approve a Preliminary Development Plan on +/-159 acres. The Preliminary Development Plan provides for up to 1,504,680 sq. ft. of light industrial and accessory commercial space, +/- 1,652 parking spaces, road improvements, landscaping, and stormwater treatment. Page 453 of 456 RESOLUTION II A RESOLUTION OF THE BOARD OF COUNTY COMMISSIONERS OF ST. LUCIE COUNTY, FLORIDA, AMENDING THE OFFICIAL ZONING ATLAS FROM THE AG-1 (AGRICULTURAL-1) ZONING DISTRICT TO THE PTV (PLANNED TOWNS AND VILLAGES) ZONING DISTRICT AND APPROVING A PRELIMINARY DEVELOPMENT PLAN ON +/-126.32 ACRES Property Owners: Brindhavanam, LLC 4528 Shiloh Mill Blvd. Jacksonville, FL 32246-1877 Applicant: Wycliffe Homes Jared Bensky Location: Approx. 900 feet south of Indrio Road, between Emerson Road and Seminole Road Parcel ID Numbers: 1323-211-0005-000-8, 1314-313-0000-000-8, 1314-323-0002-000-3, 1314-331-0001-000-1, 1314-341-0000-000-5, 1314-342-0001-000-5, PURPOSE: Proposed amendment of the Official Zoning Atlas to change the AG-1 (Agricultural-1) Zoning District to the PTV (Planned Towns and Villages) Zoning District and approve a Preliminary Regulating Plan on +/-126.32 acres. The Preliminary Development Page 454 of 456 Plan provides for up to 375 dwellings (townhouses and single-family), +/-38 acres of open space, a road connecting Seminole and Emerson Roads, club houses and other related development. The PUBLIC HEARINGS on these items will be held in the Commission Chambers, Roger Poitras Annex, 3rd Floor, St. Lucie County Administration Building, 2300 Virginia Ave., Fort Pierce, FL on Thursday, July 16, 2026, beginning at 6:00 pm or as soon thereafter as possible. All interested persons in attendance will be allowed to be heard. Written comments received in advance of the public hearings will also be considered. Written comments should be received by the Planning and Development Services Department - Planning Division at least three (3) days before the scheduled hearing. The petition files are available for review at the Planning & Development Services Dept.–Planning Offices located at 2300 Virginia Ave., Fort Pierce, FL, during regular business hours. Please call (772) 462-1562 or TDD (772) 462-1428 if you have any questions or require additional information about either petition. The St. Lucie County Planning & Zoning Commission has the power to review and make recommendations to the St. Lucie County Board of County Commissioners, for approval or disapproval, of any applications within their area of responsibility. The proceedings of the Planning and Zoning Commission are electronically recorded. PURSUANT TO SECTION 286.0105, FLORIDA STATUTES, if a person decides to appeal any decision made with respect to any matter considered at a meeting or hearing, he or she Page 455 of 456 will need a record of the proceedings. For such purpose, he or she may need to ensure that a verbatim record of the proceedings is made, which record includes the testimony and evidence upon which the appeal is to be based. Upon the request of any party to the proceeding, individuals testifying during a hearing will be sworn in. Any party to the proceeding will be granted an opportunity to cross-examine any individual testifying during a hearing upon request. If it becomes necessary, a public hearing may be continued to a date certain. Anyone with a disability requiring an accommodation to attend this meeting should contact the St. Lucie County Risk Manager at least forty-eight (48) hours prior to the meeting at (772) 462-1546 or T.D.D. (772) 462-1428. ST. LUCIE COUNTY, FLORIDA PLANNING AND ZONING COMMISSION RYAN BINNER, CHAIR PUBLISH DATE: Friday, JULY 3, 2026 18 pt. type for heading No smaller than 2 column inches wide by 10 inches long Send Proof to: irene.szedlmayer@stlucieco.gov Send Bill to: barriosm@stlucieco.org St. Lucie County Planning and Development Services Department 2300 Virginia Avenue Fort Pierce, FL 34982 Phone - (772) 462-2822 Page 456 of 456